WorldWideScience

Sample records for rhenium 192

  1. Rhenium

    Science.gov (United States)

    John, David A.; Seal, Robert R.; Polyak, Désirée E.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Rhenium is one of the rarest elements in Earth’s continental crust; its estimated average crustal abundance is less than 1 part per billion. Rhenium is a metal that has an extremely high melting point and a heat-stable crystalline structure. More than 80 percent of the rhenium consumed in the world is used in high-temperature superalloys, especially those used to make turbine blades for jet aircraft engines. Rhenium’s other major application is in platinum-rhenium catalysts used in petroleum refining.Rhenium rarely occurs as a native element or as its own sulfide mineral; most rhenium is present as a substitute for molybdenum in molybdenite. Annual world mine production of rhenium is about 50 metric tons. Nearly all primary rhenium production (that is, rhenium produced by mining rather than through recycling) is as a byproduct of copper mining, and about 80 percent of the rhenium obtained through mining is recovered from the flue dust produced during the roasting of molybdenite concentrates from porphyry copper deposits. Molybdenite in porphyry copper deposits can contain hundreds to several thousand grams per metric ton of rhenium, although the estimated rhenium grades of these deposits range from less than 0.1 gram per metric ton to about 0.6 gram per metric ton.Continental-arc porphyry copper-(molybdenum-gold) deposits supply most of the world’s rhenium production and have large inferred rhenium resources. Porphyry copper mines in Chile account for about 55 percent of the world’s mine production of rhenium; rhenium is also recovered from porphyry copper deposits in the United States, Armenia, Kazakhstan, Mexico, Peru, Russia, and Uzbekistan. Sediment-hosted strata-bound copper deposits in Kazakhstan (of the sandstone type) and in Poland (of the reduced-facies, or Kupferschiefer, type) account for most other rhenium produced by mining. These types of deposits also have large amounts of identified rhenium resources. The future supply of rhenium is likely

  2. Spherical rhenium metal powder

    International Nuclear Information System (INIS)

    Leonhardt, T.; Moore, N.; Hamister, M.

    2001-01-01

    The development of a high-density, spherical rhenium powder (SReP) possessing excellent flow characteristics has enabled the use of advanced processing techniques for the manufacture of rhenium components. The techniques that were investigated were vacuum plasma spraying (VPS), direct-hot isostatic pressing (D-HIP), and various other traditional powder metallurgy processing methods of forming rhenium powder into near-net shaped components. The principal disadvantages of standard rhenium metal powder (RMP) for advanced consolidation applications include: poor flow characteristics; high oxygen content; and low and varying packing densities. SReP will lower costs, reduce processing times, and improve yields when manufacturing powder metallurgy rhenium components. The results of the powder characterization of spherical rhenium powder and the consolidation of the SReP are further discussed. (author)

  3. Rhenium radioisotopes for therapeutic radiopharmaceutical development

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Pinkert, J.; Kropp, J.; Lin, W.Y.; Wang, S.Y.

    2001-01-01

    Rhenium-186 and rhenium-188 represent two important radioisotopes which are of interest for a variety of therapeutic applications in oncology, nuclear medicine and interventional cardiology. Rhenium-186 is directly produced in a nuclear reactor and the 90 hour half-life allows distribution to distant sites. The relatively low specific activity of rhenium-186 produced in most reactors, however, permits use of phosphonates, but limits use for labelled peptides and antibodies. Rhenium-188 has a much shorter 16.9 hour half-life which makes distribution from direct reactor production difficult. However, rhenium-188 can be obtained carrier-free from a tungsten-188/rhenium-188 generator, which has a long useful shelf-life of several months which is cost-effective, especially for developing regions. In this paper we discuss the issues associated with the production of rhenium-186- and rhenium-188 and the development and use of various radiopharmaceuticals and devices labelled with these radioisotopes for bone pain palliation, endoradiotherapy of tumours by selective catheterization and tumour therapy using radiolabelled peptides and antibodies, radionuclide synovectomy and the new field of vascular radiation therapy. (author)

  4. Rhenium Re

    International Nuclear Information System (INIS)

    Busev, A.I.; Tiptsova, V.G.; Ivanov, V.M.

    1978-01-01

    The basic methods for determining rhenium in various objects are presented. The gravimetric determination of rhenium is based on a quantitative precipitation of ReO 4 - ions with tetraphenylarsonium chloride. The determination is not hindered by tungstates and molybdates. The potentiometric determination of rhenium in alloys (>=0.5% Re) is based on perrhenate ion reduction to Re(4) with the titrated solution of the Cr(2) salt. Re(7) is titrated in a hot sulfuric acid solution in the presence of KJ. The relative error of the method is 1 to 3%. The photometric determination of rhenium is performed by the rhodamide method in molybdenum-and tungsten-containing alloys and catalytically, in rocks, after it has been separated in the form of sulfide. The extraction-photometric determination of rhenium is carried out with the aid of methyl violet (analysis of a stock with a high content of Mo, W, Ta, Nb, Ti ahd Zr) and thio-oxine (the determination of Re is hindered by Au, Pt, Pd, Ru, Os, Rh, Ir). Also described are methods for differential-spectrophotometric determination of Re with the aid of thiocarbamide, as well as with the aid of dimethylglyoxime in the presence of SnCl 2 in an acid medium when Re is determined in its alloys with niobium and hafnium. It takes 2 hours to analyze the Hf-Re alloy and 3 hours to analyze the Nb-Re alloy, the standard deviation being 0.005 at 30-50% Re and 0.027 to 0.019 at 10-50% Re

  5. Electrochemical behaviour of rhenium-graphite electrode

    International Nuclear Information System (INIS)

    Varypaev, V.N.; Krasikov, V.L.

    1980-01-01

    Electrochemical behaviour of combination electrode from graphite with electrodeposited thin coating of electrolytic rhenium is studied. Solution of 0.5 m NaCl+0.04 m AlCl 3 served as an electrolite. Polarization galvanostatic curves of hydrogen evolution upon electrodes with conditional rhenium thickness of 3.5 and 0.35 μm, 35 and 3.5 nm are obtained. Possibility of preparation of rhenium-graphite cathode with extremely low rhenium consume, electro-chemical properties of which are simu-lar to purely rhenium cathode is shown. Such electrode is characterized with stable in time low cathode potential of hydrogen evolution in chloride electrolyte and during cathode polarization it is not affected by corrosion

  6. Rhenium carbene complexes and their applications; Rhenium-Carben-Komplexe und ihre Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Hille, Claudia Heidi

    2016-01-25

    New pharmaceutically suitable metal complexes play an important role in the development of diagnostic and therapeutic agents for cancer treatment. One option concerning new radiopharmaceuticals, is the application of the rhenium isotopes {sup 186}Re and {sup 188}Re. Therefore, water soluble but at the same time stable complexes, which can be synthesized straightforward, are required. In this thesis, several synthetic pathways to such rhenium complexes bearing Nheterocyclic carbenes are presented and applicability tests of literature known complexes conducted. The selected target structures based on monocarbenes turned out to be inappropriate for use in radiopharmaceutical applications, due to their long reaction times and purification issues. Additionally, sterical and electronical effects of the carbene ligands concerning complex formation have been investigated. Possibilities of functionalization at different positions on the heterocycle as well as hydrophilic wingtips - to achieve a better stability in an aqueous media - have been examined to gain information about chemical and physical properties of the resulting complexes. Furthermore, experiments regarding the coordination of various biscarbene ligands, which provides besides the stable chelatisation additionally the possibility of varying the linking bridge, to rhenium(I/V) precursors, have been performed. Dioxo-bis-(1,1{sup '}-methylene-bis(3,3{sup '}-diisopropylimidazolium-2-ylidene)) rhenium(V )-hexafluorophosphate was synthesized via a transmetalation reaction of the corresponding silver carbene with ReOCl{sub 3}(PPh{sub 3}){sub 2} and silver hexafluorophosphate. This complex provided the basis for the first radiolabeled {sup 188}Rhenium NHC complex later on. An enhancement of the kinetic and thermodynamic stability of potential rhenium biscarbene complexes based on modifications concerning the length and character of the bridging moiety between the chelating NHC rings as well as the nature of

  7. Rhenium Rocket Manufacturing Technology

    Science.gov (United States)

    1997-01-01

    The NASA Lewis Research Center's On-Board Propulsion Branch has a research and technology program to develop high-temperature (2200 C), iridium-coated rhenium rocket chamber materials for radiation-cooled rockets in satellite propulsion systems. Although successful material demonstrations have gained much industry interest, acceptance of the technology has been hindered by a lack of demonstrated joining technologies and a sparse materials property data base. To alleviate these concerns, we fabricated rhenium to C-103 alloy joints by three methods: explosive bonding, diffusion bonding, and brazing. The joints were tested by simulating their incorporation into a structure by welding and by simulating high-temperature operation. Test results show that the shear strength of the joints degrades with welding and elevated temperature operation but that it is adequate for the application. Rhenium is known to form brittle intermetallics with a number of elements, and this phenomena is suspected to cause the strength degradation. Further bonding tests with a tantalum diffusion barrier between the rhenium and C-103 is planned to prevent the formation of brittle intermetallics.

  8. Near-Net Shape Powder Metallurgy Rhenium Thruster

    Science.gov (United States)

    Leonhardt, Todd; Hamister, Mark; Carlen, Jan C.; Biaglow, James; Reed, Brian

    2001-01-01

    This paper describes the development of a method to produce a near-net shape (NNS) powder metallurgy (PM) rhenium combustion chamber of the size 445 N (100 lbf) used in a high performance liquid apogee engine. These engines are used in low earth Orbit and geostationary orbit for satellite positioning systems. The developments in near-net shape powder metallurgy rhenium combustion chambers reported in this paper will reduce manufacturing cost of the rhenium chambers by 25 percent, and reduce the manufacturing time by 30 to 40 percent. The quantity of rhenium metal powder used to produce a rhenium chamber is reduced by approximately 70 percent and the subsequent reduction in machining schedule and costs is nearly 50 percent.

  9. Directed light fabrication of rhenium components

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.O.; Thoma, D.J.; Lewis, G.K.

    1997-02-01

    Directed Light Fabrication (DLF) is a direct metal deposition process that fuses powder, delivered by gas into the focal zone of a high powered laser beam to form fully dense near-net shaped components. This is accomplished in one step without the use of molds, dies, forming, pressing, sintering or forging equipment. DLF is performed in a high purity inert environment free from the contaminants associated with conventional processing such as oxide and carbon pickup, lubricants, binding agents, cooling or cleaning agents. Applications using rhenium have historically been limited in part by its workability and cost. This study demonstrates the ability to fuse rhenium metal powder, using a DLF machine, into free standing rods and describes the associated parameter study. Microstructural comparisons between DLF deposited rhenium and commercial rhenium sheet product is performed. This research combined with existing DLF technology demonstrates the feasibility of forming complex rhenium, metal shapes directly from powder.

  10. Thermal conduction and linear expansion of sintered rhenium and tungsten-rhenium alloys at a temperature up to 1000 K

    International Nuclear Information System (INIS)

    Pozdnyak, N.Z.; Belyaev, R.A.; Vavilov, Yu.V.; Vinogradov, Yu.G.; Serykh, G.M.

    1978-01-01

    Preparation technology (by powder metallurgy methods) of sintered rhenium and tungsten-rhenium VR-5, VR-10, and VR-20 alloys is described. Thermal conduction of rhenium and VR-20 alloy has been measured in the temperature range from 300 to 1000 K. The value obtained turned out to be considerably less than those published elsewhere, this testifies to the great thermal contact resistance between the material grains. Also measured is the mean linear expansion coefficient for the mentioned above materials in the same temperature range. Linear expansion increases with rhenium content increase

  11. Rhenium-osmium geochemistry: method and applications

    International Nuclear Information System (INIS)

    Luck, J.M.

    1982-03-01

    Experimental methods for chemical separation and isotopic analysis of rhenium-osmium are described. Accurate determinations are obtained for a quantity ratio around 10 -6 -10 -7 g. Development as a geochemical tracer is examined. Study of rhenium-osmium in meteorites allows the determination of solar system chronology and age of the galaxy. Rhenium-osmium chronology in meteorites is improved and osmium isotopes are used as petrogenetic and geological tracers. Molybdenites are studied through 187 Re- 187 Os dating [fr

  12. Crystallochemistry of rhenium compounds with metal-metal bonds

    International Nuclear Information System (INIS)

    Koz'min, P.A.; Surazhskaya, M.D.

    1980-01-01

    A review is presented including a brief description of atomic structure of 59 coordination rhenium compounds with metal-metal bond. The most important bond lengths and valent angles are presented for each compound. The dependence of rhenium-rhenium bond length on its multiplicity is discussed and possible causes of deviations from this dependence (namely, axial ligand presence, steric repulsion of ligands) are considered. On the basis of qualitative comparison of electronegativity of ligands in dimer compounds with quarternary bond of rhenium-rhenium a supposition is made on the influence of formal charge of atomic group and summary electro-negativity of ligands on the possibility of the metal-metal bond formation

  13. Rhenium Nanochemistry for Catalyst Preparation

    Directory of Open Access Journals (Sweden)

    Vadim G. Kessler

    2012-08-01

    Full Text Available The review presents synthetic approaches to modern rhenium-based catalysts. Creation of an active center is considered as a process of obtaining a nanoparticle or a molecule, immobilized within a matrix of the substrate. Selective chemical routes to preparation of particles of rhenium alloys, rhenium oxides and the molecules of alkyltrioxorhenium, and their insertion into porous structure of zeolites, ordered mesoporous MCM matrices, anodic mesoporous alumina, and porous transition metal oxides are considered. Structure-property relationships are traced for these catalysts in relation to such processes as alkylation and isomerization, olefin metathesis, selective oxidation of olefins, methanol to formaldehyde conversion, etc.

  14. Rhenium corrosion in chloride melts

    International Nuclear Information System (INIS)

    Stepanov, A.D.; Shkol'nikov, S.N.; Vetyukov, M.M.

    1989-01-01

    The results investigating rhenium corrosion in chloride melts containing sodium, potassium and chromium ions by a gravimetry potentials in argon atmosphere in a sealing quarth cell are described. Rhenium corrosion is shown to be rather considerable in melts containing CrCl 2 . The value of corrosion rate depending on temperature is determined

  15. Thiocarbonyl complexes of rhenium. Pt. 1

    International Nuclear Information System (INIS)

    Abram, U.

    1993-01-01

    Novel rhenium complexes with terminal thiocarbonyl groups have been synthesized from ReCl 3 (Me 2 PhP) 3 and sodium diethyldithiocarbamate. mer-(Diethyldithiocarbamato)tris-(dimethylphenylphosphine)(thiocarbonyl)rhenium( I), mer-[Re(CS)(Me 2 PhP) 3 (Et 2 dtc)], and tris(diethyldithiocarbamato)(thiocarbonyl)rhenium(III), [Re(CS)(Et 2 dtc) 3 ] have been studied by infrared and NMR spectroscopy, mass spectrometry and X-ray diffraction. mer-[Re(CS)(Me 2 PhP) 3 (Et 2 dtc)] crystallizes orthorhombic in the space group P na 2 1 with a=1516.1(2), b=2189.8(2) and c=1035.6(1) pm. Structure solution and refinement converged at R=0.042. The coordination geometry is a distorted octahedron. The Re-C bond length is found to be 184(2) pm. [Re(CS)(Et 2 dtc) 3 ] crystallizes monoclinic in the space group P2 1 /c with a=962.2(6), b=1744.0(2), c=1537.4(6) pm and β=96.21(1) . The final R value is 0.028. In the monomeric complex the rhenium atom is seven-coordinate with an approximate pentagonal-bipyramidal coordination sphere and a rhenium-carbon distance of 181(1) pm. (orig.)

  16. Near net shape of powder metallurgy rhenium parts

    International Nuclear Information System (INIS)

    Leonhardt, T.; Downs, J.

    2001-01-01

    In this paper, a description of the stages of processing necessary to produce a near-net shape (NNS) powder metallurgy (PM) rhenium component through the use of cold isostatic pressing (CIP) to form a complex shape will be explained. This method was primarily developed for the production of the 440 N and 490 N liquid apogee engine combustion chambers used in satellite positioning systems. The CIP to NNS process has been used in the manufacture and production of other rhenium aerospace components as well. Cold isostatic pressing (CIP) to a near net shape utilizing a one or two-part mandrel greatly reduces the quantity of rhenium required to produce the component, and also significantly reduces the number of secondary machining operations necessary to complete the manufacturing process. Further, the developments in near-net shape powder metallurgy rhenium manufacturing techniques have generated significant savings in the area of both time and budget. Overall, cost declined by as much as 35 % for the quantity of rhenium chambers, and manufacturing time was decreased by 30-40 %. The quantity of rhenium metal powder used to produce a rhenium chamber was reduced by approximately 70 %, with a subsequent reduction of nearly 50 % in secondary machining operation schedules. Thus, it is apparent that the overall savings provided by the production of near-net shape powder metallurgy rhenium components will be more than merely another aspect of any project involving high temperature applications, it will constitute significant benefit. (author)

  17. Development of industrial hydrogenating catalyst on rhenium base

    International Nuclear Information System (INIS)

    Chistyakova, G.A.; Bat', I.I.; Rebrova, V.V.

    1975-01-01

    Processes for forming rhenium catalysts on carbon carrier and their catalytic properties in nitrobenzene (NB) reduction were studied. Application of an ammonia preparation to the carbon surface produced impregnated carbon saturated at room temperature with a water solution of the ammonia preparation, taken in a volume equal to the volumetric capacity of the carbon. With one impregnation, 2% rhenium was taken up. Catalysts containing more than 5% rhenium were obtained by impregnating the carbon with heating and use of more concentrated solutions. Catalysts made in this way and dried at 100 0 C had the composition Re 2 OH/carbon/. The most active catalysts were those reduced at 200-250 0 C; higher temperatures, up to 300-500 0 C, decreased the activity. Study of the catalytic properties of the rhenium catalysts in a liquid phase reduction of NB showed that the specific activity of rhenium depends only slightly on the content of the active component in the catalyst and is close to the specific activity of palladium and considerably exceeds that of nickel. Study of the effect of the NB concentration and hydrogen pressure on the activity and stability of the 5% rhenium catalyst indicated that with NB concentrations from 50 to 10% the process takes place at an essentially constant rate; the order of the reaction was close to zero with an apparent activation energy of about 7000 cal/mole. At pressures of 15-200 atm the yield with the 5% catalyst was proportional to the hydrogen pressure. A big advantage of the rhenium catalysts in the reduction of NB is their high selectivity. With a higher activity than palladium and nickel catalysts, 5% rhenium catalyst produces a high operating capacity in a wide range of contact charges, which has considerable significance for industrial use in contact apparatus of the column type. Comparison of the costs of rhenium catalysts and granular carbon carrier with those of nickel, platinum, and palladium showed that 5% rhenium catalyst can

  18. First principles calculations of interstitial and lamellar rhenium nitrides

    Energy Technology Data Exchange (ETDEWEB)

    Soto, G., E-mail: gerardo@cnyn.unam.mx [Universidad Nacional Autonoma de Mexico, Centro de Nanociencias y Nanotecnologia, Km 107 Carretera Tijuana-Ensenada, Ensenada Baja California (Mexico); Tiznado, H.; Reyes, A.; Cruz, W. de la [Universidad Nacional Autonoma de Mexico, Centro de Nanociencias y Nanotecnologia, Km 107 Carretera Tijuana-Ensenada, Ensenada Baja California (Mexico)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer The possible structures of rhenium nitride as a function of composition are analyzed. Black-Right-Pointing-Pointer The alloying energy is favorable for rhenium nitride in lamellar arrangements. Black-Right-Pointing-Pointer The structures produced by magnetron sputtering are metastable variations. Black-Right-Pointing-Pointer The structures produced by high-pressure high-temperature are stable configurations. Black-Right-Pointing-Pointer The lamellar structures are a new category of interstitial dissolutions. - Abstract: We report here a systematic first principles study of two classes of variable-composition rhenium nitride: i, interstitial rhenium nitride as a solid solution and ii, rhenium nitride in lamellar structures. The compounds in class i are cubic and hexagonal close-packed rhenium phases, with nitrogen in the octahedral and tetrahedral interstices of the metal, and they are formed without changes to the structure, except for slight distortions of the unit cells. In the compounds in class ii, by contrast, the nitrogen inclusion provokes stacking faults in the parent metal structure. These faults create trigonal-prismatic sites where the nitrogen residence is energetically favored. This second class of compounds produces lamellar structures, where the nitrogen lamellas are inserted among multiple rhenium layers. The Re{sub 3}N and Re{sub 2}N phases produced recently by high-temperature and high-pressure synthesis belong to this class. The ratio of the nitrogen layers to the rhenium layers is given by the composition. While the first principle calculations point to higher stability for the lamellar structures as opposed to the interstitial phases, the experimental evidence presented here demonstrates that the interstitial classes are synthesizable by plasma methods. We conclude that rhenium nitrides possess polymorphism and that the two-dimensional lamellar structures might represent an emerging class of materials

  19. First principles calculations of interstitial and lamellar rhenium nitrides

    International Nuclear Information System (INIS)

    Soto, G.; Tiznado, H.; Reyes, A.; Cruz, W. de la

    2012-01-01

    Highlights: ► The possible structures of rhenium nitride as a function of composition are analyzed. ► The alloying energy is favorable for rhenium nitride in lamellar arrangements. ► The structures produced by magnetron sputtering are metastable variations. ► The structures produced by high-pressure high-temperature are stable configurations. ► The lamellar structures are a new category of interstitial dissolutions. - Abstract: We report here a systematic first principles study of two classes of variable-composition rhenium nitride: i, interstitial rhenium nitride as a solid solution and ii, rhenium nitride in lamellar structures. The compounds in class i are cubic and hexagonal close-packed rhenium phases, with nitrogen in the octahedral and tetrahedral interstices of the metal, and they are formed without changes to the structure, except for slight distortions of the unit cells. In the compounds in class ii, by contrast, the nitrogen inclusion provokes stacking faults in the parent metal structure. These faults create trigonal-prismatic sites where the nitrogen residence is energetically favored. This second class of compounds produces lamellar structures, where the nitrogen lamellas are inserted among multiple rhenium layers. The Re 3 N and Re 2 N phases produced recently by high-temperature and high-pressure synthesis belong to this class. The ratio of the nitrogen layers to the rhenium layers is given by the composition. While the first principle calculations point to higher stability for the lamellar structures as opposed to the interstitial phases, the experimental evidence presented here demonstrates that the interstitial classes are synthesizable by plasma methods. We conclude that rhenium nitrides possess polymorphism and that the two-dimensional lamellar structures might represent an emerging class of materials within binary nitride chemistry.

  20. Concentration of rhenium from dilute sodium chloride solutions

    Directory of Open Access Journals (Sweden)

    DRAGOLJUB M. LUKIC

    2008-03-01

    Full Text Available The conditions for the desorption of rhenium from the anion exchange resin Dowex 1-x8 by HNO3, HCl, H2SO4 and NaOH were determined. The solution (5.0´10-3 mol dm-3 Re in 0.15 mol dm-3 NaCl was passed through a column containing 0.10 g of the resin. The total sorbed amount of rhenium was 0.20 g/g of the resin. It was then eluted by the corresponding eluent in the concentration range up to about 3.0 mol dm-3. The highest elution efficiency and the most favourable elution profile were found with 3.0 mol dm-3 HNO3. Over 77 % of the sorbed rhenium was found in the first 5 ml of the eluate. Practically all the rhenium was recovered with 20 ml of the acid. Under the given experimental conditions, HCl and H2SO4 were less favourable while NaOH was not applicable, due to very low efficiency of rhenium elution.

  1. Ambient aging of rhenium filaments used in thermal ionization mass spectrometry: Growth of oxo-rhenium crystallites and anti-aging strategies

    Directory of Open Access Journals (Sweden)

    Joseph M. Mannion

    2017-01-01

    Full Text Available Degassing is a common preparation technique for rhenium filaments used for thermal ionization mass spectrometric analysis of actinides, including plutonium. Although optimization studies regarding degassing conditions have been reported, little work has been done to characterize filament aging after degassing. In this study, the effects of filament aging after degassing were explored to determine a “shelf-life” for degassed rhenium filaments, and methods to limit filament aging were investigated. Zone-refined rhenium filaments were degassed by resistance heating under high vacuum before exposure to ambient atmosphere for up to 2 months. After degassing the nucleation and preferential growth of oxo-rhenium crystallites on the surface of polycrystalline rhenium filaments was observed by atomic force microscopy and scanning electron microscopy (SEM. Compositional analysis of the crystallites was conducted using SEM-Raman spectroscopy and SEM energy dispersive X-ray spectroscopy, and grain orientation at the metal surface was investigated by electron back-scatter diffraction mapping. Spectra collected by SEM-Raman suggest crystallites are composed primarily of perrhenic acid. The relative extent of growth and crystallite morphology were found to be grain dependent and affected by the dissolution of carbon into filaments during annealing (often referred to as carbonization or carburization. Crystallites were observed to nucleate in region specific modes and grow over time through transfer of material from the surface. Factors most likely to affect the rates of crystallite growth include rhenium substrate properties such as grain size, orientation, levels of dissolved carbon, and relative abundance of defect sites; as well as environmental factors such as length of exposure to oxygen and relative humidity. Thin (∼180 nm hydrophobic films of poly(vinylbenzyl chloride were found to slow the growth of oxo-rhenium crystallites on the filament

  2. Linkable thiocarbamoylbenzamidines as ligands for bioconjugation of Rhenium and Technetium; Kopplungsfaehige Thiocarbamoylbenzamidine als Liganden zur Biokonjugation von Rhenium und Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Gomez, Juan Daniel

    2015-04-27

    Bioconjugation reactions with Rhenium and Technetium are of high importance for the development of novel radiopharmaceuticals for nuclear medicine. In this thesis the possibilities for bioconjugation using linkable Thiocarmbamoylbenzamidines as ligands for the complexation of Rhenium and Technetium were examined.

  3. The kinetics of anodic dissolution of rhenium in aqueous electrolyte solutions

    International Nuclear Information System (INIS)

    Atanasyants, A.G.; Kornienko, V.A.

    1986-01-01

    The kinetics of anodic rhenium dissolution was investigated by means of potentiodynamic and potentiostatic polarization curves recorded at temperature from 293 to 333 K in different media (NaOH, KOH, NaCl, NaBr, HCl, H 2 SO 4 ) using the rotating disc technique. It is shown that the kinetics of anodic rhenium dissolution and effective activation energy depend not only on the composition and pH value of the solutions but also on the structure of the dissolving rhenium surface. The investigation of the anodic behaviour of the rhenium monocrystal revealed the existence of anisotropy of the monocrystal electrochemical properties. The experimental results point to an important role of adsorption processes in anodic rhenium dissolution. Rhenium dissolution proceeds with formation of intermediate surface adsorption complexes between the metal and the components of the solution

  4. Thermophysical measurements on solid and liquid rhenium

    International Nuclear Information System (INIS)

    Pottlacher, G.; Jager, H.; Neger, T.

    1986-01-01

    A fast resistive heating technique was used to measure such thermophysical data of solid and liquid rhenium as enthalpy, specific heat, thermal volume expansion, and electrical resistivity. The measurements are performed with heating rates of slightly more than 10 9 K s -1 up to states of superheated liquid rhenium (7500 K)

  5. Effect of Temperature and Mole Ratio on the Synthesis Yield of Rhenium-Tetrofosmin

    Directory of Open Access Journals (Sweden)

    Widyastuti

    2015-08-01

    Full Text Available Technetium-99m (99mTc tetrofosmin is widely used in nuclear medicine as a diagnostic agent for myocardial perfusion and as a tumor imaging agent. As a parenteral preparation it requires an evaluation of its pharmacokinetics and stability in-vivo. Since 99mTc has a short half-life and is only available in very low concentrations, it is impossible to characterize its chemical properties and presence in the body. Due to this reason, only technetium-99 (T1/2 = 5 × 105 years, which is available in macro quantities, or natural rhenium can be used for this purpose. In this study rhenium-188 (188Re tetrofosmin will be synthesized and applied, because non-radioactive Re can be easily obtained. Synthesis and radiochemical purity analysis of carrier-added 188Re-tetrofosmin were carried out as a model to study the in-vivo stability of technetium-99m tetrofosmin. Rhenium-188 was used as a tracer to identify the formation of rhenium tetrofosmin. Rhenium gluconate was synthesized first prior to the formation of rhenium tetrofosmin. The quality of labeling for both rhenium gluconate and rhenium tetrofosmin was analyzed using paper- and thin-layer chromatography, respectively. Rhenium gluconate can be synthesized with high labeling yield within 1 hour, whereas rhenium tetrofosmin was synthesized both in room temperature and in an elevated temperature with various tetrofosmin-to-rhenium mole ratios.The results showed that heating at 95oC led to a higher yield of more than 90% within 30 minutes. Rhenium tetrofosmin could be produced in high radiochemical purity using an excess of tetrofosmin with mole ratio of 2000. It is concluded that rhenium tetrofosmin could be synthesized through the formation of rhenium gluconate, and a higher yield could be obtained in a shorter time by heating process.

  6. Determination of rhenium in geologic samples of sandstone-type uranium deposit

    International Nuclear Information System (INIS)

    Li Yanan; Wang Xiuqin; Yin Jinshuang

    1997-01-01

    The thiourea colorimetry method suitable for the determination of samples with rhenium content higher than 5 μg/g is described. The method is characterized by many advantages: stability of analytical results, simplicity and cheapness of reagent, and wide range of analysed samples. The catalytic colorimetry is also applied to determine trace rhenium meeting the demand for comprehensive appraisal of prospecting and exploration, recovery and utilization of rhenium. This method can also be applied to analyse rhenium of other samples

  7. Work function of carburized rhenium

    International Nuclear Information System (INIS)

    Pallmer, P.G. Jr.; Gordon, R.L.; Dresser, M.J.

    1980-01-01

    Variations of the electronic work function of carburized rhenium foils containing approximately 5 at.% carbon have been observed using the contact potential difference technique. Surface work function was observed to vary between 5.25 and 4.1 eV, with the work function of pure rhenium taken as 5.0 eV. Decrease in work function has been ascribed to the formation of graphitic layers on the surface at temperatures below the temperature of saturated solubility. The high work function surface was observed with all carbon in solution and has been ascribed to the presence of amorphous carbon near the surface

  8. Accelerator Production and Separations for High Specific Activity Rhenium-186

    Energy Technology Data Exchange (ETDEWEB)

    Jurisson, Silvia S. [Univ. of Missouri, Columbia, MO (United States); Wilbur, D. Scott [Univ. of Washington, Seattle, WA (United States)

    2016-04-01

    Tungsten and osmium targets were evaluated for the production of high specific activity rhenium-186. Rhenium-186 has potential applications in radiotherapy for the treatment of a variety of diseases, including targeting with monoclonal antibodies and peptides. Methods were evaluated using tungsten metal, tungsten dioxide, tungsten disulfide and osmium disulfide. Separation of the rhenium-186 produced and recycling of the enriched tungsten-186 and osmium-189 enriched targets were developed.

  9. Electrocatalysis of the hydrogen evolution reaction by rhenium oxides electrodeposited by pulsed-current

    International Nuclear Information System (INIS)

    Vargas-Uscategui, Alejandro; Mosquera, Edgar; Chornik, Boris; Cifuentes, Luis

    2015-01-01

    Highlights: • Rhenium oxides were produced by means of pulsed current electrodeposition over ITO. • The electrocatalytic behavior of rhenium oxides electrodeposited over ITO was studied. • Electrodeposited rhenium oxides showed electrocatalytic behavior increasing the rate of the hydrogen evolution reaction. • The electrocatalysis behavior was explained considering the relative abundance of Re species on the surface of the electrodeposited material. - Abstract: Rhenium oxides are materials of interest for applications in the catalysis of reactions such as those occurring in fuel cells and photoelectrochemical cells. This research work was devoted to the production of rhenium oxide by means of pulsed current electrodeposition for the electrocatalysis of the hydrogen evolution reaction (HER). Rhenium oxides were electrodeposited over a transparent conductive oxide substrate (Indium Tin-doped Oxide – ITO) in an alkaline aqueous electrolyte. The electrodeposition process allowed the production of rhenium oxides islands (200–600 nm) with the presence of three oxidized rhenium species: Re"I"V associated to ReO_2, Re"V"I associated to ReO_3 and Re"V"I"I associated to H(ReO_4)H_2O. Electrodeposited rhenium oxides showed electrocatalytic behavior over the HER and an increase of one order of magnitude of the exchange current density was observed compared to the reaction taking place on the bare substrate. The electrocatalytic behavior varied with the morphology and relative abundance of oxidized rhenium species in the electrodeposits. Finally, two mechanisms of electrocatalysis were proposed to explain experimental results.

  10. Rhenium: a rare metal critical in modern transportation

    Science.gov (United States)

    John, David A.

    2015-01-01

    Rhenium is a silvery-white, metallic element with an extremely high melting point (3,180 degrees Celsius) and a heat-stable crystalline structure, making it exceptionally resistant to heat and wear. Since the late 1980s, rhenium has been critical for superalloys used in turbine blades and in catalysts used to produce lead-free gasoline.

  11. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Aneeqa, E-mail: aneeqa.khan-3@postgrad.manchester.ac.uk [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); De Temmerman, Gregory [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046 - 13067 St Paul Lez Durance Cedex (France); Morgan, Thomas W. [FOM Institute DIFFER – Dutch Institute for Fundamental Energy Research, Partner in the Trilateral Euregio Cluster, Eindhoven (Netherlands); Ward, Michael B. [Institute for Materials Research, School of Chemical Process Engineering, University of Leeds, Leeds, LS2 9JT (United Kingdom)

    2016-06-15

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to be dependent on time, temperature and flux. Initial fuzz growth was seen to be highly dependent on grain orientation, with rhenium having little effect. Once the fuzz was fully developed, the effect of grain orientation disappeared and the rhenium had an inhibiting effect on growth. This could be beneficial for inhibiting fuzz growth in a future fusion reactor, where transmutation of tungsten to rhenium is expected. It also appears that erosion or annealing of the fuzz is limiting growth of fuzz at higher temperatures in the range of ∼1340 °C.

  12. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    International Nuclear Information System (INIS)

    Khan, Aneeqa; De Temmerman, Gregory; Morgan, Thomas W.; Ward, Michael B.

    2016-01-01

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to be dependent on time, temperature and flux. Initial fuzz growth was seen to be highly dependent on grain orientation, with rhenium having little effect. Once the fuzz was fully developed, the effect of grain orientation disappeared and the rhenium had an inhibiting effect on growth. This could be beneficial for inhibiting fuzz growth in a future fusion reactor, where transmutation of tungsten to rhenium is expected. It also appears that erosion or annealing of the fuzz is limiting growth of fuzz at higher temperatures in the range of ∼1340 °C.

  13. Determination of rhenium in ores of complex composition by the kinetic method

    Energy Technology Data Exchange (ETDEWEB)

    Pavlova, L G; Gurkina, T V [Kazakhskij Gosudarstvennyj Univ., Alma-Ata (USSR); Tsentral' naya Lab. Yuzhno-Kazakhstanskogo Geologicheskogo Upravleniya, Alma-Ata (USSR))

    1979-09-01

    The kinetic rhenium determination method is proposed based on rhenium catalytic effect in the reaction of malachite green with thiourea. The accompanying elements, excluding molybdenum, do not interfere with the rhenium determination at their concentration of up to 0.1 M. The interfering influence of molybdenum can be eliminated by addition of tartaric acid to the solution up to the concentration of 0.1 M. This enables to determine rhenium in presence of 1000-fold quantity of molybdenum. The method is applicable for the analysis of complex copper-zinc sulphide ores.

  14. Nipponium, the element ascribable to rhenium from the modern chemical viewpoint

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, H.K. [Japan Isotope Data Inst., Sendai (Japan)

    1997-11-01

    Though the discovery of nipponium by Ogawa in 1908 was judged to be false and his work was forgotten for many years, the new element he believed to have found should be ascribed to rhenium (z = 75) by the following reasons: (1) the spectral line of 4882 A agrees well with the present data of rhenium, (2) recalculation of the atomic weight of the element supports the value in the neighbourhood of 185 which is very close to the present value 186.2 of rhenium, and (3) rhenium is actually present in Japanese molybdenite he studied. Therefore, it is concluded that his discovery of the `new` element was correct, but assignment of z = 43 was wrong. (orig.)

  15. Method of stably radiolabeling antibodies with technetium and rhenium

    International Nuclear Information System (INIS)

    Paik, C.H.; Reba, R.C.; Eckelman, W.C.

    1987-01-01

    A method is described for labeling antibodies or antibody fragments with radionuclides of technetium or rhenium to obtain stable labeling, comprising: reacting a reduced radioisotope of technetium or rhenium with an antibody or antibody fragment, or a diethylenetriaminepentaacetic acid conjugated antibody or antibody fragment, in the presence of free or carrier-bound diethylenetriaminepentaacetic acid (DTPA). The amount of DTPA is sufficient to substantially completely inhibit binding of the reduced technetium or rhenium to nonstable binding sites of the antibody or antibody fragment, or the DTPA-conjugated antibody or antibody fragment. The resultant stably labeled antibody or antibody fragment, or DTPA[conjugated antibody or antibody fragment is recovered

  16. Separation of Rhenium (VII) from Tungsten (VI)

    International Nuclear Information System (INIS)

    Vucina, J.; Lukic, D.; Stoiljkovic, M.; Milosevic, M.; Orlic, M.

    2004-01-01

    Examined were the conditions for an effective separation of tungsten (VI) and rhenium (VII) on alumina if the solution of 0.20 mol dm -3 NaCl, ph=2.6 is used as the aqueous phase. Under the given experimental conditions alumina was found to be much better adsorbent for tungsten than for rhenium. The breakthrough and saturation capacities of alumina at pH=2 are 24 and 78 mg W/g Al 2 O 3 , respectively. With the increase of pH these values decrease. So, at pH=6 they are only 4 and 13 mg W/g Al 2 O 3 respectively. The elution volume for rhenium for the given column dimensions and quantity of the adsorbent is about 16 ml. These results were confirmed by the experiments of the radiological separations. Tungsten-187 remains firmly bound to the alumina. The radionuclide purity of the eluted 186'188 Re at pH=2 is very high. (authors)

  17. Determination of rhenium in molybdenite by neutron-activation analysis.

    Science.gov (United States)

    Terada, K; Yoshimura, Y; Osaki, S; Kiba, T

    1967-01-01

    A neutron-activation method is described for the determination of rhenium in molybdenite. Radiochemical separation by a carrier technique was carried out very rapidly by means of successive liquid-liquid extraction processes. The recovery of rhenium, which was determined by a spectrophotometric method, was about 93%. About 10 samples could be analysed within 6 hr in parallel runs.

  18. A comparative study of electrochemical and optical properties of rhenium deposited on gold and platinum

    Energy Technology Data Exchange (ETDEWEB)

    Zerbino, Jorge O.; Castro Luna, Ana M.; Martins, M. E. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina). Inst. de Investigaciones Fisico-Quimicas, Teoricas y Aplicadas (INIFTA)]. E-mail: mmartins@inifta.unlp.edu.ar; Zinola, Carlos F.; Mendez, Eduardo [Universidad de la Republica, Montevideo (Uruguay). Facultad de Ciencias. Lab. de Electroquimica Fundamental

    2002-08-01

    Rhenium-containing films were grown on gold and platinum after different potentiostatic and potentiodynamic polarizations in the - 0.20 V to 0.70 V range (vs rhe) in aqueous acid perrhenate. Experimental data were obtained using cyclic voltammetry and ellipsometry, from which the thickness and optical indices of the electrodeposited rhenium layer were calculated. Metallic rhenium deposition on gold takes place at potentials within the hydrogen evolution reaction. Rhenium oxide on platinum is formed in the hydrogen adatom potential domain, whereas metallic rhenium is deposited concurrently with the hydrogen adsorption and evolution reactions on the same metal. (author)

  19. A comparative study of electrochemical and optical properties of rhenium deposited on gold and platinum

    Directory of Open Access Journals (Sweden)

    Zerbino Jorge O.

    2002-01-01

    Full Text Available Rhenium-containing films were grown on gold and platinum after different potentiostatic and potentiodynamic polarizations in the - 0.20 V to 0.70 V range (vs rhe in aqueous acid perrhenate. Experimental data were obtained using cyclic voltammetry and ellipsometry, from which the thickness and optical indices of the electrodeposited rhenium layer were calculated. Metallic rhenium deposition on gold takes place at potentials within the hydrogen evolution reaction. Rhenium oxide on platinum is formed in the hydrogen adatom potential domain, whereas metallic rhenium is deposited concurrently with the hydrogen adsorption and evolution reactions on the same metal.

  20. New leads for fragment-based design of rhenium/technetium radiopharmaceutical agents.

    Science.gov (United States)

    Brink, Alice; Helliwell, John R

    2017-05-01

    Multiple possibilities for the coordination of fac -[Re(CO) 3 (H 2 O) 3 ] + to a protein have been determined and include binding to Asp, Glu, Arg and His amino-acid residues as well as to the C-terminal carboxylate in the vicinity of Leu and Pro. The large number of rhenium metal complex binding sites that have been identified on specific residues thereby allow increased target identification for the design of future radiopharmaceuticals. The core experimental concept involved the use of state-of-art tuneable synchrotron radiation at the Diamond Light Source to optimize the rhenium anomalous dispersion signal to a large value ( f '' of 12.1 electrons) at its L I absorption edge with a selected X-ray wavelength of 0.9763 Å. At the Cu  K α X-ray wavelength (1.5418 Å) the f '' for rhenium is 5.9 electrons. The expected peak-height increase owing to the optimization of the Re f '' was therefore 2.1. This X-ray wavelength tuning methodology thereby showed the lower occupancy rhenium binding sites as well as the occupancies of the higher occupancy rhenium binding sites.

  1. New leads for fragment-based design of rhenium/technetium radiopharmaceutical agents

    Directory of Open Access Journals (Sweden)

    Alice Brink

    2017-05-01

    Full Text Available Multiple possibilities for the coordination of fac-[Re(CO3(H2O3]+ to a protein have been determined and include binding to Asp, Glu, Arg and His amino-acid residues as well as to the C-terminal carboxylate in the vicinity of Leu and Pro. The large number of rhenium metal complex binding sites that have been identified on specific residues thereby allow increased target identification for the design of future radiopharmaceuticals. The core experimental concept involved the use of state-of-art tuneable synchrotron radiation at the Diamond Light Source to optimize the rhenium anomalous dispersion signal to a large value (f′′ of 12.1 electrons at its LI absorption edge with a selected X-ray wavelength of 0.9763 Å. At the Cu Kα X-ray wavelength (1.5418 Å the f′′ for rhenium is 5.9 electrons. The expected peak-height increase owing to the optimization of the Re f′′ was therefore 2.1. This X-ray wavelength tuning methodology thereby showed the lower occupancy rhenium binding sites as well as the occupancies of the higher occupancy rhenium binding sites.

  2. Monoclonal Antibodies Radiolabeling with Rhenium-188 for Radioimmunotherapy

    Science.gov (United States)

    Martini, Petra; Pasquali, Micol

    2017-01-01

    Rhenium-188, obtained from an alumina-based tungsten-188/rhenium-188 generator, is actually considered a useful candidate for labeling biomolecules such as antibodies, antibody fragments, peptides, and DNAs for radiotherapy. There is a widespread interest in the availability of labeling procedures that allow obtaining 188Re-labeled radiopharmaceuticals for various therapeutic applications, in particular for the rhenium attachment to tumor-specific monoclonal antibodies (Mo)Abs for immunotherapy. Different approaches have been developed in order to obtain 188Re-radioimmunoconjugates in high radiochemical purity starting from the generator eluted [188Re]ReO4−. The aim of this paper is to provide a short overview on 188Re-labeled (Mo)Abs, focusing in particular on the radiolabeling methods, quality control of radioimmunoconjugates, and their in vitro stability for radioimmunotherapy (RIT), with particular reference to the most important contributions published in literature in this topic. PMID:28951872

  3. Manufacture and properties of molybdenum-rhenium alloys

    International Nuclear Information System (INIS)

    Fischer, B.; Freund, D.

    2001-01-01

    It is necessary to measure strength and creep behavior to guarantee the safe and reliable usage of refractory alloys at extremely high temperatures. In the literature there is very little information available about the properties of Mo-Re alloys at temperatures higher than 1000 C. A special test facility has been designed and built for stress-rupture testing at very high temperatures (up to 3000 C) of refractory metals and alloys in inert atmospheres. - The stress-rupture strength as well as the creep behavior of molybdenum-rhenium alloys with rhenium contents between 41 and 51 wt.% have been determined at temperatures ranging from 1200 to 2000 C, and rupture times of up to 10 hours using this facility. Previous measurements of stress-rupture strength and creep behavior of pure rhenium have been compared with the measurement results of Mo-Re alloys. - The discussion of the values measured is based on metallographic test results and scanning electron microscopy (SEM) images of Mo-Re alloy samples after stress-rupture testing. (orig.) [de

  4. Electrodialysis separation of rhenium from silicon

    International Nuclear Information System (INIS)

    Prasolova, O.D.; Borisova, L.V.; Ermakov, A.N.

    1989-01-01

    A method of separation of ruthenium from silicon by electrodialysis with heterogenuos ion-exchange membranes is developed. The effeciency of purification of rhenium from silicon depending on the number of dialyzer chambers, temperature and pH value of the dialyzate is studed. It is found that an addditional fourth chamber between the middle and anolytic ones causes the purification coefficient increase 50 times. It is necessary to cool the dialyzate in order to reduce silicon migration into the anolyte and reverse diffusion of perrhenate-ion from the anolyte into the dialyzate. The optimal pH value of diaizate is 5.5-6. The method developed has been used for separating rhenium from industrial solution of lead production with complex composition

  5. Determination of rhenium in molybdenite by X-ray fluorescence: A combined chemical-spectrometric technique.

    Science.gov (United States)

    Solt, M W; Wahlberg, J S; Myers, A T

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

  6. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    Science.gov (United States)

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  7. Clustering of transmutation elements tantalum, rhenium and osmium in tungsten in a fusion environment

    Science.gov (United States)

    You, Yu-Wei; Kong, Xiang-Shan; Wu, Xuebang; Liu, C. S.; Fang, Q. F.; Chen, J. L.; Luo, G.-N.

    2017-08-01

    The formation of transmutation solute-rich precipitates has been reported to seriously degrade the mechanical properties of tungsten in a fusion environment. However, the underlying mechanisms controlling the formation of the precipitates are still unknown. In this study, first-principles calculations are therefore performed to systemically determine the stable structures and binding energies of solute clusters in tungsten consisting of tantalum, rhenium and osmium atoms as well as irradiation-induced vacancies. These clusters are known to act as precursors for the formation of precipitates. We find that osmium can easily segregate to form clusters even in defect-free tungsten alloys, whereas extremely high tantalum and rhenium concentrations are required for the formation of clusters. Vacancies greatly facilitate the clustering of rhenium and osmium, while tantalum is an exception. The binding energies of vacancy-osmium clusters are found to be much higher than those of vacancy-tantalum and vacancy-rhenium clusters. Osmium is observed to strongly promote the formation of vacancy-rhenium clusters, while tantalum can suppress the formation of vacancy-rhenium and vacancy-osmium clusters. The local strain and electronic structure are analyzed to reveal the underlying mechanisms governing the cluster formation. Employing the law of mass action, we predict the evolution of the relative concentration of vacancy-rhenium clusters. This work presents a microscopic picture describing the nucleation and growth of solute clusters in tungsten alloys in a fusion reactor environment, and thereby explains recent experimental phenomena.

  8. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    NARCIS (Netherlands)

    Khan, A.; De Temmerman, G.; Morgan, T. W.; M. B. Ward,

    2016-01-01

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to

  9. Electrodeposition of rhenium-tin nanowires

    International Nuclear Information System (INIS)

    Naor-Pomerantz, Adi; Eliaz, Noam; Gileadi, Eliezer

    2011-01-01

    Highlights: → Rhenium-tin nanowires were formed electrochemically, without using a template. → The nanowires consisted of a crystalline-Sn-core/amorphous-Re-shell structure. → The effects of bath composition and operating conditions were investigated. → A mechanism is suggested for the formation of the core/shell structure. → The nanowires may be attractive for a variety of applications. - Abstract: Rhenium (Re) is a refractory metal which exhibits an extraordinary combination of properties. Thus, nanowires and other nanostructures of Re-alloys may possess unique properties resulting from both Re chemistry and the nanometer scale, and become attractive for a variety of applications, such as in catalysis, photovoltaic cells, and microelectronics. Rhenium-tin coatings, consisting of nanowires with a core/shell structure, were electrodeposited on copper substrates under galvanostatic or potentiostatic conditions. The effects of bath composition and operating conditions were investigated, and the chemistry and structure of the coatings were studied by a variety of analytical tools. A Re-content as high as 77 at.% or a Faradaic efficiency as high as 46% were attained. Ranges of Sn-to-Re in the plating bath, applied current density and applied potential, within which the nanowires could be formed, were determined. A mechanism was suggested, according to which Sn nanowires were first grown on top of Sn micro-particles, and then the Sn nanowires reduced the perrhenate chemically, thus forming a core made of crystalline Sn-rich phase, and a shell made of amorphous Re-rich phase. The absence of mutual solubility of Re and Sn may be the driving force for this phase separation.

  10. Neutron activation determination of rhenium in shales shales and molybdenites

    International Nuclear Information System (INIS)

    Zajtsev, E.I.; Radinovich, B.S.

    1977-01-01

    Described is the technique for neutron activation determination of rhenium in shales and molybdenites with its radiochemical extraction separation by methyl-ethyl ketone. The sensitivity of the analysis is 5x10 -7 %. Experimental checking of the developed technique in reference to the analysis of shales and molybdenites was carried out. Estimated is the possibility of application of X-ray gamma-spectrometer to instrumental determination of rhenium in molybdenites

  11. Synthesis and study of rhenium (5) complexes with benzimidazole and rubeanic acid

    Energy Technology Data Exchange (ETDEWEB)

    Basitova, S M; Yurina, R D; Kotegov, K V; Amindzhanov, A A

    1986-01-01

    Mixed rhenium (5) oxohalide complex compounds with benzimidazole and rubeanic acid are synthesized. Composition of the compounds obtained is established by IR spectroscpy thermal and chemical analyses. It is shown that rhenium (5) chloride compound stability to pyrolysis is rather lower than that of the corresponding bromide derivatives.

  12. Synthesis and study of rhenium (5) complexes with benzimidazole and rubeanic acid

    International Nuclear Information System (INIS)

    Basitova, S.M.; Yurina, R.D.; Kotegov, K.V.; Amindzhanov, A.A.

    1986-01-01

    Mixed rhenium (5) oxohalide complex compounds with benzimidazole and rubeanic acid are synthesized. Composition of the compounds obtained is established by IR spectroscpy thermal and chemical analyses. It is shown that rhenium (5) chloride compound stability to pyrolysis is rather lower than that of the corresponding bromide derivatives

  13. Rhenium Mechanical Properties and Joining Technology

    Science.gov (United States)

    Reed, Brian D.; Biaglow, James A.

    1996-01-01

    Iridium-coated rhenium (Ir/Re) provides thermal margin for high performance and long life radiation cooled rockets. Two issues that have arisen in the development of flight Ir/Re engines are the sparsity of rhenium (Re) mechanical property data (particularly at high temperatures) required for engineering design, and the inability to directly electron beam weld Re chambers to C103 nozzle skirts. To address these issues, a Re mechanical property database is being established and techniques for creating Re/C103 transition joints are being investigated. This paper discusses the tensile testing results of powder metallurgy Re samples at temperatures from 1370 to 2090 C. Also discussed is the evaluation of Re/C103 transition pieces joined by both, explosive and diffusion bonding. Finally, the evaluation of full size Re transition pieces, joined by inertia welding, as well as explosive and diffusion bonding, is detailed.

  14. Mechanistic Study of Oxygen Atom Transfer Catalyzed by Rhenium Compounds

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Xiaopeng [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    Two ionic and one neutral methyl(oxo)rhenium(V) compounds were synthesized and structurally characterized. They were compared in reactivity towards the ligands triphenylphosphane, pyridines, pyridine N-oxides. Assistance from Broensted bases was found on ligand displacement of ionic rhenium compounds as well as nucleophile assistance on oxidation of all compounds. From the kinetic data, crystal structures, and an analysis of the intermediates, a structural formula of PicH+3- and mechanisms of ligand displacement and oxidation were proposed.

  15. Lymph node scintigraphy with sup(99m)Tc-rhenium colloid

    International Nuclear Information System (INIS)

    Mitsuhata, Naoki; Suyama, Bunzo; Matsumura, Yosuke; Ohmori, Hiroyuki

    1981-01-01

    Lymph node scintigraphy with sup(99m)Tc-rhenium colloid in evaluation of nodal involvement by urological malignancy were performed on twelve cases (4 bladder cancer, 3 prostatic cancer, 2 penile cancer and 3 testicular tumor). These cases had been examined the extent of disease on the basis of findings at pedal lymphangiography, urography, computed tomography or laparotomy. sup(99m)Tc-rhenium colloid in a volume of 0.2 ml (2 mCi) was injected into the first interdigital webs of each foot without local anesthesia. In one case of penile cancer radioactive colloid was directly injected into the glans penis and prepuce including tumor area. Our clinical experience reported here reveals that lymph node scintigraphy with sup(99m)Tc-rhenium colloid can provide a useful method of investigating the lymphatic system. This technique is reproducible and can be performed in poor risk patients or pediatric patients readily and safely. (author)

  16. Study of the electrodeposition of rhenium thin films by electrochemical quartz microbalance and X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Schrebler, R.; Cury, P.; Suarez, C.; Munoz, E.; Vera, F.; Cordova, R.; Gomez, H.; Ramos-Barrado, J.R.; Leinen, D.; Dalchiele, E.A.

    2005-01-01

    Rhenium thin films were prepared by electrodeposition from an aqueous solution containing 0.1 M Na 2 SO 4 +H 2 SO 4 , pH 2 in presence of y mM HReO 4 . As substrates polycrystalline gold (y=0.75 mM HReO 4 ) and monocrystalline n-Si(100) (y=40 mM HReO 4 ) were used. The electrochemical growth of rhenium was studied by cyclic voltammetry and electrochemical quartz microbalance on gold electrodes. The results found in the potential region before the hydrogen evolution reaction (her) showed that ReO 3 , ReO 2 and Re 2 O 3 with different hydration grades can be formed. In the potential region where the her is occurring, either on gold or n-Si(100) the electrodeposition of metallic rhenium takes place. On both substrates, rhenium films were formed by electrolysis at constant potential and X-ray photoelectron spectroscopy technique was used to characterise these deposits. It was concluded that the electrodeposited films were of metallic rhenium and only the uppermost atomic layer contained rhenium oxide species

  17. High-temperature extraction of rhenium from sulfuric acid solutions with trialkylamines

    International Nuclear Information System (INIS)

    Gladyhev, V.P.; Andreeva, N.N.; Kim, E.M.; Kovaleva, S.V.

    1985-01-01

    This paper attempts to determine the possibility of conducting high-temperature extraction of rhenium from sulfuric acid solutions with trialkylamines (TAA) using higher hydrocarbon-paraffin mixtures as the diluent of the extraction system. Substitution of kerosene by paraffin in the extraction system would permit decreasing the danger of fire and explosions during he extraction process. In extracting rhenium from industrial solutions with a melt of higher paraffins containing TAA and alcohols, the extraction system can be continously heated in heat exchangers through which washing sulfuric acid passes and then goes to the extractor. This permits utilizing the heat and decreases the temperature of the solutions for extraction to the optimum temperatures. Extraction of rhenium with a melt of trioctylamine in paraffin obeys the same mechanisms as high-temperature extraction of ruthenium (IV) by amines in kerosene and aromatic hydrocarbons

  18. Influence of nano-cluster compounds of rhenium drugs on the activity of liver enzymes in a tumor model

    Directory of Open Access Journals (Sweden)

    J. V. Suponko

    2010-06-01

    Full Text Available Enzymes’ level in rat’s hepatocytes under Guerin's carcinoma T8 development as well as after injection of rhenium compounds and cis-platin has been studied. It has been determined that the decrease of enzymatic activity to the level of the animals of control group was observed at the simultaneous injection of cis-platin and cluster rhenium compounds in nanoliposomal and water-soluble forms. That confirms possible hepatoprotective properties of the rhenium compounds. It has been shown that hepatoprotective properties of rhenium cluster compounds mostly don’t depend on the form of their injection and are detected regardless of anticancer properties. Rhenium-platinum system with β-alanine ligand in aqueous solution, has been found. Its injection is accompanied by the hepatoprotective effect.

  19. Reductive coupling of carbon monoxide in a rhenium carbonyl complex with pendant Lewis acids.

    Science.gov (United States)

    Miller, Alexander J M; Labinger, Jay A; Bercaw, John E

    2008-09-10

    Phosphinoborane ligands impart unique reactivity to a rhenium carbonyl cation relative to simple phosphine complexes. Addition of either triethylborohydride or a platinum hydride (that can be formed from H2) forms a rhenium boroxycarbene. This carbene, which crystallizes as a dimer, disproportionates over a period of days to afford the starting cation and a structurally unprecedented boroxy(boroxymethyl)carbene, in which a new C-C bond has been formed between two reduced CO ligands. This product of C-C bond formation can be independently synthesized by addition of 2 equiv of hydride to the rhenium carbonyl cation.

  20. Use of cluster rhenium substances with alkyl ligands for inhibition of the Guerin carcinoma Growth

    Directory of Open Access Journals (Sweden)

    O. S. Voronkova

    2007-04-01

    Full Text Available Quantity and quality of erythrocytes, blood haemoglobin concentration, glucose levels in the erythrocytes and plasma, content of TBA-active products in blood plasma of rats were studied during development of the Guerin carcinoma, introduction of cis-platinum and cluster rhenium substances with organic ligands. It was shown that rhenium substances had essential antioxidant effects and changed the dynamic of tumour growth. The conclusion on perspectiveness of further investigations of rhenium substances with cluster fragment and organic ligands in experiments in vivo with changed redox-status of an organism was drawn.

  1. A study of scandia and rhenium doped tungsten matrix dispenser cathode

    Science.gov (United States)

    Wang, Jinshu; Li, Lili; Liu, Wei; Wang, Yanchun; Zhao, Lei; Zhou, Meiling

    2007-10-01

    Scandia and rhenium doped tungsten powders were prepared by solid-liquid doping combined with two-step reduction method. The experimental results show that scandia was distributed evenly on the surface of tungsten particles. The addition of scandia and rhenium could decrease the particle size of doped tungsten, for example, the tungsten powders doped with Sc 2O 3 and Re had the average size of about 50 nm in diameter. By using this kind of powder, scandia and rhenium doped tungsten matrix with the sub-micrometer sized tungsten grains was obtained. This kind of matrix exhibited good anti-bombardment insensitivity at high temperature. The emission property result showed that high space charge limited current densities of more than 60 A/cm 2 at 900 °C could be obtained for this cathode. A Ba-Sc-O multilayer about 100 nm in thickness formed at the surface of cathode after activation led to the high emission property.

  2. Characterization of rhenium compounds obtained by electrochemical synthesis after aging process

    Energy Technology Data Exchange (ETDEWEB)

    Vargas-Uscategui, Alejandro, E-mail: avargasuscat@ing.uchile.cl [Departamento de Ingeniería de Minas, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile); Mosquera, Edgar [Laboratorio de Materiales a Nanoescala, Departamento de Ciencia de los Materiales, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile); López-Encarnación, Juan M. [Department of Mathematics-Physics and Department of Chemistry, University of Puerto Rico at Cayey, 205 Ave. Antonio R. Barceló, Cayey, PR 00736, USA. (Puerto Rico); Chornik, Boris [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Blanco Encalada Av. 2008, Santiago (Chile); Katiyar, Ram S. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico San Juan, San Juan, PR 00931-3343 (United States); Cifuentes, Luis [Departamento de Ingeniería de Minas, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile)

    2014-12-15

    The proper identification of the molecular nature of the aged rhenium compound obtained by means of electrodeposition from an alkaline aqueous electrolyte was determined. Chemical, structural and vibrational experimental characterization of the aged Re compound showed agreement with quantum-computations, thereby allowing the unambiguous identification of the Re compound as H(ReO{sub 4})H{sub 2}O. - Graphical abstract: Rhenium oxides were electrodeposited on a copper surface and after environmental aging was formed the H(ReO{sub 4})H{sub 2}O compound. The characterization of the synthesized material was made through the comparison of experimental evidence with quantum mechanical computations carried out by means of density functional theory (DFT). - Highlights: • Aged rhenium compound obtained by means of electrodeposition was studied. • The study was made by combining experimental and DFT-computational information. • The aged electrodeposited material is consistent with the H(ReO{sub 4})H{sub 2}O compound.

  3. Evaluation of oxide dispersion strengthened (ODS) molybdenum and molybdenum-rhenium alloys

    International Nuclear Information System (INIS)

    Mueller, A.J.; Bianco, R.; Buckman, R.W. Jr.

    1999-01-01

    Oxide dispersion strengthened (ODS) molybdenum alloys being developed for high temperature applications possess excellent high temperature strength and creep resistance. In addition they exhibit a ductile-to-brittle transition temperature (DBIT) in the worked and stress-relieved condition under longitudinal tensile load well below room temperature. However, in the recrystallized condition, the DBTT maybe near or above room temperature, depending on the volume fraction of oxide dispersion and the amount of prior work. Dilute rhenium additions (7 and 14 wt.%) to ODS molybdenum were evaluated to determine their effect on low temperature ductility. The addition of 7 wt.% rhenium to the ODS molybdenum did not significantly enhance the mechanical properties. However, the addition of 14 wt.% rhenium to the ODS molybdenum resulted in a DBTT well below room temperature in both the stress-relieved and recrystallized condition. Additionally, the tensile strength of ODS Mo-14Re is greater than the base ODS molybdenum at 1,000 to 1,250 C

  4. Influence of cold rolling and strain rate on plastic response of powder metallurgy and chemical vapor deposition rhenium

    International Nuclear Information System (INIS)

    Koeppel, B.J.; Subhash, G.

    1999-01-01

    The plastic response of two kinds of rhenium processed via powder metallurgy (PM) and chemical vapor deposition (CVD) were investigated under uniaxial compression over a range of strain rates. The PM rhenium, further cold rolled to 50 and 80 pct of the original thickness, was also investigated to assess the influence of cold work on the plastic behavior. A strong basal texture was detected in all the preceding materials as a result of processing and cold work. Both CVD and PM rhenium exhibited an increase in yield strength and flow stress with increasing strain rate. In PM rhenium, cold work resulted in an increase in hardness and yield strength and a decrease in the work hardening rate. The deformed microstructures revealed extensive twinning in CVD rhenium. At large strains, inhomogeneous deformation mode in the form of classical cup and cone fracture was noticed

  5. Nanograined Net-Shaped Fabrication of Rhenium Components by EB-PVD

    International Nuclear Information System (INIS)

    Singh, Jogender; Wolfe, Douglas E.

    2004-01-01

    Cost-effective net-shaped forming components have brought considerable interest into DoD, NASA and DoE. Electron beam physical vapor deposition (EB-PVD) offers flexibility in forming net-shaped components with tailored microstructure and chemistry. High purity rhenium (Re) components including rhenium-coated graphite balls, Re- plates and tubes have been successfully manufactured by EB-PVD. EB-PVD Re components exhibited sub-micron and nano-sized grains with high hardness and strength as compared to CVD. It is estimated that the cost of Re components manufactured by EB-PVD would be less than the current CVD and powder-HIP Technologies

  6. Effect of octanols structure on their extraction ability as regards to rhenium(VII) in sulfuric acid solutions

    International Nuclear Information System (INIS)

    Kasikov, A.G.; Petrova, A.M.

    2007-01-01

    It is established that extraction ability of octanols as regards to rhenium(VII) and sulfuric acid depends on the structure of alcohol, but if in passage from octanol-1 to octanol-3 as regard to rhenium(VII) it rises, then for H 2 SO 4 it falls. Dependence of the distribution function of rhenium from the concentration of the acid has maximums at 4-7 mol l 1- that the most distinctly it becomes apparent for secondary alcohols. Decreasing the extraction ability of octyl alcohols with the growth of H 2 SO 4 concentration more than 7 mol l 1- is connected with the change of extractant composition and forms of rhenium(VII) being in the solution [ru

  7. Treatment of liver cancer with Rhenium-188 Lipiodol: Colombian experience

    International Nuclear Information System (INIS)

    Bernal, P.; Osorio, M.; Mendoza, M.; Esguerra, R.; Ucros, G.; Gutierrez, C.; Velez, O.; Cerquera, A.M.; Padhy, A.K.

    2002-01-01

    Aim:Trans-arterial Radio-conjugate therapy plays an important role in the palliative treatment of inoperable liver cancer. It also helps in reduction of the tumor to an operable state from an inoperable one. As a part of an IAEA sponsored coordinated research project, a new radiopharmaceutical, Rhenium-188 Lipiodol has been developed. The aim of this study was to establish the safety of the radiopharmaceutical and to find out the efficacy of treatment. Materials and Methods: Eight patients suffering from various forms of liver cancer (Hepatocellular carcinoma-4, Metastases from carcinoma of colon-3 and Carcinoid- 1) were treated with Rhenium -188 Lipiodol. Seven out of the eight patients were classified as ECOG- 1 and one as ECOG- 3. Labelling of Rhenium-188 with Lipiodol was carried out according to a protocol developed under the CRP and standardized in our service. Rhenium-188 Lipiodol was administered through the trans-arterial route by either selective (75%) or ultra selective (25%) hepatic arteriography. Administered therapeutic doses ranged between 170 MBq and 4181 MBq. Dosimetric evaluations were made using the IAEA developed dosimetry spreadsheet. All patients were followed up (1-5 months, average = 2 months) after treatment by clinical examination, liver function tests, haematological examinations and CT scans of liver to determine the size of hepatic tumor. Results: Rhenium-188 Lipiodol treatment was well tolerated by all patients. No immediate systemic complications were noted in any of the patients within 72 hrs. following therapy. Only two patients had mild rise in temperature in the immediate post-therapy period, which subsided subsequently. One patient who was classified as Child B and ECOG 3, developed encephalopathy on the seventh day after treatment. He died of hepatic failure. Another one present depressive syndrome, didn't accept food and died Follow-up CT scans in all the surviving (6/8) patients revealed significant reduction of the tumours

  8. THE SYNTHESIS OF BIOCONJUGATE BASED ON RHENIUM(I CARBONYL COMPLEX FOR VISUALIZATION OF PATHOLOGICAL PROCESS

    Directory of Open Access Journals (Sweden)

    K. O. Piletska

    2017-03-01

    Full Text Available Tricarbonyl rhenium(I complexes have a great potential like biomarkers. It is caused their biological stability, low toxicity, large Stokes shifts, and long luminescence lifetimes. Rhenium tricarbonyl complexes fac-[Re(CO3(N^N], where N^N is a ligand with low π* orbitals are excellent candidates as imaging dyes. The method of obtaining potential biomarkers based on tricarbonyl rhenium(I complex with a 4-methyl-2,2’-bipyridine-4’-carboxylate by the addition of biomolecules by peptide synthesis was developed. The new complex [Re(CO3MebpyCOOHBr] was synthesized, composition and structure of which were established by mass spectrometry, IR and NMR spectroscopy. A selective attachment of receptor peptide enkephalin to complex [Re(CO3(MebpyCOOHBr] was performed. The formation of a new compound and its structure has been confirmed by HPLC and mass spectral analysis. The method which has been developed allows to connect various peptides to rhenium(I complex in the solution.

  9. Structure and x-ray density of electrochemically deposited rhenium films

    International Nuclear Information System (INIS)

    Petrovich, V.A.; Fedenkov, A.L.; Shepurev, S.Yu.

    1988-01-01

    The electrodeposition of rhenium was carried out at a constant cathode-current density and room temperature. The backing was grade KEF-0.02 single-crystal silicon. The absorption coefficient μ of the film was determined for the K α radiation of the copper line. The investigation enabled us to conclude that electrochemically deposited rhenium films can be used as a material for the masking coatings of x-ray patterns, since the absorption coefficients of the x-ray radiation of the resultant films are superior to the similar parameters of traditionally employed materials, and surpass these materials in terms of corrosion resistance and simplicity of production

  10. Determination coefficient distribution rhenium and tungsten using method extraction with solvent methyl ethyl ketone

    International Nuclear Information System (INIS)

    Riftanio Natapratama Hidayat; Maria Christina Prihatiningsih; Duyeh Setiawan

    2015-01-01

    Determination of the distribution coefficient (K d ) of the rhenium and tungsten conducted for the purpose of knowing the value of K d of the two elements. K d value determination is applied to the process of separation rhenium-188 from target of tungsten-188 for the purposes purification of radioisotopes that are made to meet the radionuclide and radiochemical purity. The K d value determination using solvent extraction with methyl ethyl ketone (MEK). Prior to the determination of K d values, determined beforehand the optimum conditions of extraction process based on the effect of agitation time, the volume of MEK, and the pH of the solution. Confirmation the results of the extraction was conducted using UV-Vis spectrophotometer with a complexing KSCN under acidic conditions and reductant SnCl 2 . The results showed that the optimum condition extraction process to feed each of 10 ppm is when the agitation for 10 minutes, the volume of MEK in 20 ml, and the pH below 5. Obtained the maximum recovery of rhenium are drawn to the organic phase as much as 9.545 ppm. However, the condition of the extraction process does not affect the migration of tungsten to the organic phase. Then the maximum K d values obtained at 2.7566 rhenium and tungsten maximum K d is 0.0873. Optimum conditions of extraction process can be further tested on radioactive rhenium and tungsten as an alternative to the separation of radioisotopes. (author)

  11. Synthesis, reactivity, and properties of N-fused porphyrin rhenium(I) tricarbonyl complexes.

    Science.gov (United States)

    Toganoh, Motoki; Ikeda, Shinya; Furuta, Hiroyuki

    2007-11-12

    The thermal reactions of N-fused tetraarylporphyrins or N-confused tetraarylporphyrins with Re2(CO)10 gave the rhenium(I) tricarbonyl complexes bearing N-fused porphyrinato ligands (4) in moderate to good yields. The rhenium complexes 4 are characterized by mass, IR, 1H, and 13C NMR spectroscopy, and the structures of tetraphenylporphynato complex 4a and its nitro derivative 15 are determined by X-ray single crystal analysis. The rhenium complexes 4 show excellent stability against heat, light, acids, bases, and oxidants. The aromatic substitution reactions of 4 proceed without a loss of the center metal to give the nitro (15), formyl (16), benzoyl (17), and cyano derivatives (19), regioselectively. In the electrochemical measurements for 4, one reversible oxidation wave and two reversible reduction waves are observed. Their redox potentials imply narrow HOMO-LUMO band gaps of 4 and are consistent with their electronic absorption spectra, in which the absorption edges exceed 1000 nm. Theoretical study reveals that the HOMO and LUMO of the rhenium complexes are exclusively composed of the N-fused porphyrin skeleton. Protonation of 4 takes place at the 21-position regioselectively, reflecting the high coefficient of the C21 atom in the HOMO orbital. The skeletal rearrangement reaction from N-confused porphyrin Re(I) complex (8) to N-fused porphyrin Re(I) complex (4) is suggested from the mechanistic study as well as DFT calculations.

  12. Extraction of rhenium(VII) by phosphorylated podands

    International Nuclear Information System (INIS)

    Turanov, A.N.; Karandashev, V.K.; Baulin, V.E.

    2006-01-01

    Interphase distribution of ReO 4 - between aqueous solutions of H 2 SO 4 and solutions of phosphoryl-containing podands in organic solvents is studied. Stoichiometry of the complexes extracted is determined. Effect of extractant structure and nature of organic solvent on efficiency of rhenium extraction into organic phase is determined [ru

  13. Chromatographic separation of rhenium in alumina-methanol/sulfuric acid system

    International Nuclear Information System (INIS)

    Oguma, Koichi

    1983-01-01

    The adsorption behavior of a number of metals on alumina was surveyed in a methanol-(0.005 -- 0.5) M H 2 SO 4 (3 : 1 v/v) developing solvent by thin-layer chromatography. Over the acid concentration range tested, Re(VII) does not favor the alumina phase to any great extent while the most other metals are strongly adsorbed on alumina. These findings allowed to establish a column chromatographic technique for selective separation of rhenium in a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) eluent. The separation technique thus established was applied to molybdenite analysis for rhenium. About 100-mg powdered sample containing ca. 100 ppm rhenium was decomposed with HNO 3 and then evaporated nearly to dryness. The residue was dissolved in NH 4 OH and the excess NH 4 OH was expelled by evaporation to dryness. The residue was dissolved in 2.5-ml 0.5 M H 2 SO 4 and 10-ml water, the insoluble materials filtered off, and the filtrate diluted to exactly 25 ml with water. A 10-ml aliquot of this solution was mixed with 30-ml methanol and the mixture was passed through a column (diameter 15 mm, bed height 30 mm) containing 5 g of alumina. The column was then washed with 20 ml of a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) mixture. Rhenium was recovered from the loaded solution and the subsequent washings, and was determined spectrophotometrically with Methylene Blue as a chromogenic reagent. The values obtained from four samples of molybdenite are in good agreement with those obtained by neutron activation analysis. The relative standard deviation (n = 4; calculated from the range) was between 2.0 and 5.2 %. (author)

  14. Electrodeposition of rhenium from chloride melts: Electrochemical nature, structure and applied aspects

    Directory of Open Access Journals (Sweden)

    Vinogradov-Zhabrov O.N.

    2003-01-01

    Full Text Available Processes involved in the electrodeposition of rhenium from chloride melts have been studied over the temperature interval from 680 to 970 0C at a cathodic current density of 5 to 250 mA/cm2. It has been found that rhenium is deposited in the form of continuous layers. In addition to that the growth of deposits as separate single-crystal needles has also been noticed. Continuous layers had axial growth textures. The crystallographic direction of the textures is due to electrolysis conditions, such as concentration of oxygen-containing impurities, temperature, melt composition and cathodic current density. When the concentration of oxygen-containing impurities in the melt decreased, electrolysis temperature increased, the average radius of the supporting electrolyte cations became smaller, or cathodic current density diminished, the direction of the growth textures was changing as follows: (1010 →(1120 →(101L →(0001 →(0001needles. The microhardness of the deposits in this series is 900 to 250 kg/mm2. The growth of deposits on textured rhenium substrates and single crystals having different orientations, including bent substrates, was studied. It has been found that the epitaxial growth is virtually unlimited in depth if the orientation of the substrate coincides with the growth texture under given conditions. If the substrate orientation deviated from the growth texture, the epitaxial growth was nearly absent. Kinetic parameters were measured using the galvanostatic method. The exchange current density was determined over the interval of (0.01-0.1 A/cm2 depending on the concentration of oxygen-containing impurities, cation composition, type of the surface and its condition. The parameter α⋅Z, which was estimated by two methods, was equal to 2.1-3.1. The diffusion coefficient of rhenium ions has been found to be 2.8 ⋅10 −5 cm2/s at 790 0C and 3.5 ⋅10 −5 cm2/s at 840 0C. Galvanoplastic production of rhenium products, such as

  15. Influence of the acid and basic properties of rhenium oxide supported on alumina catalyst on the catalytic performance in olefin metathesis; Influence des proprietes acido-basiques de l`oxyde de rhenium supporte sur les performances catalytiques en metathese des olefines

    Energy Technology Data Exchange (ETDEWEB)

    Nahama, F.

    1996-11-30

    The aim of this work is to study the influence of the acid-basic properties of rhenium oxide supported on alumina catalyst on the catalytic performance in olefin metathesis. The literature data indicate that the environment of the active site does possess acid properties. However, the nature of the acid sites is still matter of debate. Concerning the Re O{sub x} - Al{sub 2}O{sub 3} interactions, we have shown that perrhenate ions are electrostatically absorbed on alumina. The uptake of rhenium is favoured at acidic pH (below 4), and the absorbed rhenium is in equilibrium with rhenium in solution. The results of rhenium extraction by water strongly suggest that the surface compounds of the calcined Re{sub 2}O{sub 7}/Al{sub 2}O{sub 3} materials is aluminium perrhenate. Characterization of surface acidity of the catalyst by infrared spectroscopy reveals that the initiation of the metathesis reaction is governed essentially by Lewis acidity. This strongly supports the role of Lewis acidity, which is exalted by the increase of the rhenium content and the calcination temperature. Finally, we point out by ammonia adsorption-thermodesorption a band at 1320 cm{sup -1} characteristic of the Lewis acidity of aluminium perrhenate. This result is a second indication of the presence of aluminium perrhenate on the Re{sub 2}O{sub 7}/Al{sub 2}O{sub 3} catalyst surface. (author)

  16. Development of unified X-ray fluorescent analysis to determine rhenium content in multicomponent oxide compositions

    International Nuclear Information System (INIS)

    Drobot, D.V.; Belyaev, A.V.; Kutvitskij, V.A.; Rysev, A.P.

    1999-01-01

    A procedure to prepare rhenium-containing glass-like specimens on the basis of bismuth and boron oxides is proposed. The glasses produced are studied by X-ray fluorescent analysis and routine spectrometric thiocyanate analysis. The results make it possible to determine rhenium in oxide mixtures in the range of its content 0.01 - 10% with S r = 0.03 [ru

  17. A Study on the Trapping Characteristics of Rhenium Oxide Using Ca(OH)_2

    International Nuclear Information System (INIS)

    Lee, Tae-Kyo; Eun, Hee-Chul; Choi, Jung-Hoon; Lee, Ki-Rak; Han, Seung-Youb; Park, Hwan-Seo

    2017-01-01

    The objective of this study was to obtain basic data for trapping gaseous technetium (Tc) oxide generated from the voloxidation process in spent nuclear fuel pyroprocessing. Rhenium (Re) and Ca(OH)_2 were used as surrogates for the technetium and a trapping material, respectively. The trapping characteristics of rhenium oxide were investigated with changing temperatures and molar ratios of calcium (Ca) over rhenium, and the thermal behaviors of the trapping products were observed. The products following after the trapping test were identified as Ca(ReO_4)_2 and Ca_5Re_2O_1_2. The conversion to Ca_5Re_2O_1_2 was preferred with increasing temperatures, and the trapping products were completely converted into Ca5Re2O12 under conditions exceeding 800 ℃, or when maintained at 750 ℃ for 4 hr. The trapping efficiency at a molar ratio of 2.5 (Ca:Re=5:2) was significantly superior to that at the molar ratio of 2.

  18. Tungsten-rhenium composite tube fabricated by CVD for application in 18000C high thermal efficiency fuel processing furnace

    International Nuclear Information System (INIS)

    Svedberg, R.C.; Bowen, W.W.; Buckman, R.W. Jr.

    1980-04-01

    Chemical Vapor Deposit (CVD) rhenium was selected as the muffle material for an 1800 0 C high thermal efficiency fuel processing furnace. The muffle is exposed to high vacuum on the heater/insulation/instrumentation side and to a flowing argon-8 V/0 hydrogen gas mixture at one atmosphere pressure on the load volume side. During operation, the muffle cycles from room temperature to 1800 0 C and back to room temperature once every 24 hours. Operational life is dependent on resistance to thermal fatigue during the high temperature exposure. For a prototypical furnace, the muffle is approximately 13 cm I.D. and 40 cm in length. A small (about one-half size) rhenium closed end tube overcoated with tungsten was used to evaluate the concept. The fabrication and testing of the composite tungsten-rhenium tube and prototypic rhenium muffle is described

  19. Influence of ligand structure on anticancer and antioxidant properties of rhenium cluster compounds

    Directory of Open Access Journals (Sweden)

    I. V. Leus

    2009-11-01

    Full Text Available Under the model growth of T8 Guerin’s carcinoma in rats we studied the anticancer activity of the system rhenium-platinum, which includes cis-dicarboxylates of rhenium (III with different alkyl ligands, erythrocytes number and its morphological structure, erythrocytic stability, blood haemoglobin concentration, catalase activity and concentration of TBA-active products in the rats blood plasma. The renium-platinum system had considerable antioxidat effect and prevented the growth of tumour, that was maximal for a compound with the pivalate ligand.

  20. Determination of rhenium (7) trace amounts by spectrophotometric titration in medium of mixed solvents

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.

    1978-01-01

    The method has been proposed of determining rhenium (7) microamounts by spectrophotometric titration in the medium water-dimethyl-sulphoxide with the reagent nitrochromazo. The method is based on the formation of ionic pairs K + ReO 4 - in water-organic solvents. The results of rhenium determination are satisfactory in a wide concentration range up to 0.3 mkg in 15 ml which makes the method proposed close in sensitivity to photometric methods and much better in reproducibility

  1. Reductive Coupling of Carbon Monoxide in a Rhenium Carbonyl Complex with Pendant Lewis Acids

    OpenAIRE

    Miller, Alexander J. M.; Labinger, Jay A.; Bercaw, John E.

    2008-01-01

    Phosphinoborane ligands impart unique reactivity to a rhenium carbonyl cation relative to simple phosphine complexes. Addition of either triethylborohydride or a platinum hydride (that can be formed from H2) forms a rhenium boroxycarbene. This carbene, which crystallizes as a dimer, disproportionates over a period of days to afford the starting cation and a structurally unprecedented boroxy(boroxymethyl)carbene, in which a new C−C bond has been formed between two reduced CO ligands. This prod...

  2. Tungsten - rhenium alloys wire: overview of thermomechanical processing and properties data

    International Nuclear Information System (INIS)

    Bryskin, B.

    2001-01-01

    The scope of this study encompasses the compositional modifications of the tungsten-rhenium dual system (W-3/5 Re up to W-27 Re) as well as some of the tungsten-molybdenum-rhenium ternary system. The alloys of interest are considered with a specific representation of powder metallurgy route based on doped or undoped tungsten vs. vacuum melted materials. This paper constitutes an in-depth review of structural and mechanical properties and systematic compilation of challenges necessary to provide the quality consistency of severely drawn filaments. The issue of thermomechanical processing trends is addressed as an important part of W-Re fabrication technology to achieve further improvement in design properties of rod and wire. (author)

  3. Noncontact surface tension and viscosity measurements of rhenium in the liquid and undercooled states

    International Nuclear Information System (INIS)

    Ishikawa, Takehiko; Paradis, Paul-Francois; Yoda, Shinichi

    2004-01-01

    Surface tension and viscosity of liquid rhenium, which have hardly been measured due to the extremely high melting temperature of rhenium, were measured using an electrostatic levitation method combined with the oscillation drop technique. Sample position instability problems caused by the photon pressure of the heating lasers and by sample evaporation were solved by modifying the electrodes design. Good sample stability allowed the measurements of the surface tension and the viscosity over wide temperature ranges including the undercooled states. Over the 2800-3600 K interval, the surface tension of rhenium was measured as σ(T)=2.71x10 3 -0.23(T-T m ), where T m is the melting temperature, 3453 K. At T m , the datum agrees well with the literature values. Similarly, on the same temperature range, the viscosity was determined as η(T)=0.08 exp[1.33x10 5 /(RT)] (mPa s)

  4. Laser welding parameters for manufacturing iridium-192 (Ir-192) source

    International Nuclear Information System (INIS)

    Anung Pujiyanto; Moch Subechi; Hotman Lubis; Diandono KY

    2013-01-01

    Number of cervical cancer patients in Indonesia is growing every year. One of cervical cancer treatment was fairly effective use brachytherapy treatment with radioisotope sources of iridium-192. Manufacturing of iridium sources for brachytherapy can be done by incorporating the iridium-192 into stainless steel microcapsules then welding using laser welder which the quality of the welding of iridium source (Ir-192) was determined by the welding parameters such as full power, energy frequency, average power and speed. Based on the result of leakage test using pressure -20 inch Hg and tensile test 2.5 bar showed the welding parameters III and IV did not have leakage and damaged. So that parameters III and IV are recommended to be applied to Ir-192 HDR's source. (author)

  5. Monte Carlo criticality analysis of simple geometries containing tungsten-rhenium alloys engrained with uranium dioxide and uranium mononitride

    International Nuclear Information System (INIS)

    Webb, Jonathan A.; Charit, Indrajit

    2011-01-01

    Highlights: → The addition of rhenium to the tungsten matrix within W-UO 2 and W-UN CERMET materials can help reduce the risk of submersion criticality accidents while increasing the strength and ductility of tungsten based nuclear fuel elements. → The addition of rhenium up to 30 at.% to simple geometries containing W-UO 2 mixtures can increase the critical mass by 65 kg. → The addition of rhenium up to 30 at.% to simple geometries containing W-UN mixtures can increase the critical mass by 22 kg. → The addition of rhenium by up to 30 at.% to simple geometries containing W-UO 2 mixtures can reduce the change in reactivity change due to water submersion by $5.07. → The addition of rhenium by up to 30 at.% to simple geometries containing W-UN mixtures can reduce the change in reactivity due to water submersion by $3.24. - Abstract: The critical mass and dimensions of simple geometries containing highly enriched uranium dioxide (UO 2 ) and uranium mononitride (UN) encapsulated in tungsten-rhenium alloys are determined using MCNP5 criticality calculations. Spheres as well as cylinders with length to radius ratios of 1.82 are computationally built to consist of 60 vol.% fuel and 40 vol.% metal matrix. Within the geometries, the uranium is enriched to 93 wt.% uranium-235 and the rhenium content within the metal alloy was modeled over the range of 0-30 at.%. The spheres containing UO 2 were determined to have a critical radius of 18.29-19.11 cm and a critical mass ranging from 366 kg to 424 kg. The cylinders containing UO 2 were found to have a critical radius ranging from 17.07 cm to 17.84 cm with a corresponding critical mass of 406-471 kg. Spheres engrained with UN were determined to have a critical radius ranging from 14.82 cm to 15.19 cm and a critical mass between 222 kg and 242 kg. Cylinders which were engrained with UN were determined to have a critical radius ranging from 13.81 cm to 14.15 cm and a corresponding critical mass of 245-267 kg. The critical

  6. Rhenium solubility in borosilicate nuclear waste glass: implications for the processing and immobilization of technetium-99.

    Science.gov (United States)

    McCloy, John S; Riley, Brian J; Goel, Ashutosh; Liezers, Martin; Schweiger, Michael J; Rodriguez, Carmen P; Hrma, Pavel; Kim, Dong-Sang; Lukens, Wayne W; Kruger, Albert A

    2012-11-20

    The immobilization of technetium-99 ((99)Tc) in a suitable host matrix has proven to be a challenging task for researchers in the nuclear waste community around the world. In this context, the present work reports on the solubility and retention of rhenium, a nonradioactive surrogate for (99)Tc, in a sodium borosilicate glass. Glasses containing target Re concentrations from 0 to 10,000 ppm [by mass, added as KReO(4) (Re(7+))] were synthesized in vacuum-sealed quartz ampules to minimize the loss of Re from volatilization during melting at 1000 °C. The rhenium was found as Re(7+) in all of the glasses as observed by X-ray absorption near-edge structure. The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) using inductively coupled plasma optical emission spectroscopy. At higher rhenium concentrations, additional rhenium was retained in the glasses as crystalline inclusions of alkali perrhenates detected with X-ray diffraction. Since (99)Tc concentrations in a glass waste form are predicted to be wastes, assuming Tc as Tc(7+) and similarities between Re(7+) and Tc(7+) behavior in this glass system.

  7. Effect of rhenium irradiations on the mechanical properties of tungsten for nuclear fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Aneeqa, E-mail: aneeqa.khan-3@postgrad.manchester.ac.uk [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); Elliman, Robert; Corr, Cormac [Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601 (Australia); Lim, Joven J.H.; Forrest, Andrew [School of Materials, The University of Manchester, M13 9PL (United Kingdom); Mummery, Paul [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); Evans, Llion M. [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom)

    2016-08-15

    As-received and annealed tungsten samples were irradiated at a temperature of 400 °C with Re and W ions to peak concentrations of 1600 appm (atomic parts per million) and damage levels of 40 dpa (displacements per atom). Mechanical properties were investigated using nanoindentation, and the orientation and depth dependence of irradiation damage was investigated using Electron Back Scatter Diffraction (EBSD). Following irradiation there was a 13% increase in hardness in the as received sheet and a 23% increase in the annealed material for both tungsten and rhenium irradiation. The difference between the tungsten and rhenium irradiated samples was negligible, suggesting that for the concentrations and damage levels employed, the presence of rhenium does not have a significant effect on the hardening mechanism. Energy dependent EBSD of annealed samples provided information about the depth distribution of the radiation damage in individual tungsten grains and confirmed that the radiation damage is orientation dependant.

  8. Submersion criticality safety of tungsten-rhenium urania cermet fuel for space propulsion and power applications

    Energy Technology Data Exchange (ETDEWEB)

    Craft, A.E., E-mail: aaron.craft@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); O’Brien, R.C., E-mail: Robert.OBrien@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); Howe, S.D., E-mail: Steven.Howe@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); King, J.C., E-mail: kingjc@mines.edu [Nuclear Science and Engineering Program, Metallurgical and Materials Engineering Department, Colorado School of Mines, Golden, CO 80401 (United States)

    2014-07-01

    Highlights: • Criticality safety studies consider a generic space nuclear reactor in reentry scenarios. • Describes the submersion criticality behavior for a reactor fueled with a tungsten cermet fuel. • Study considers effects of varying fuel content, geometry, and other conditions. - Abstract: Nuclear thermal rockets are the preferred propulsion technology for a manned mission to Mars, and tungsten–uranium oxide cermet fuels could provide significant performance and cost advantages for nuclear thermal rockets. A nuclear reactor intended for use in space must remain subcritical before and during launch, and must remain subcritical in launch abort scenarios where the reactor falls back to Earth and becomes submerged in terrestrial materials (including seawater, wet sand, or dry sand). Submersion increases reflection of neutrons and also thermalizes the neutron spectrum, which typically increases the reactivity of the core. This effect is typically very significant for compact, fast-spectrum reactors. This paper provides a submersion criticality safety analysis for a representative tungsten/uranium oxide fueled reactor with a range of fuel compositions. Each submersion case considers both the rhenium content in the matrix alloy and the uranium oxide volume fraction in the cermet. The inclusion of rhenium significantly improves the submersion criticality safety of the reactor. While increased uranium oxide content increases the reactivity of the core, it does not significantly affect the submersion behavior of the reactor. There is no significant difference in submersion behavior between reactors with rhenium distributed within the cermet matrix and reactors with a rhenium clad in the coolant channels. The combination of the flooding of the coolant channels in submersion scenarios and the presence of a significant amount of spectral shift absorbers (i.e. high rhenium concentration) further decreases reactivity for short reactor cores compared to longer cores.

  9. Separation of tungsten and rhenium on alumina

    Directory of Open Access Journals (Sweden)

    MILOVAN SM. STOILJKOVIC

    2004-09-01

    Full Text Available The conditions for the efficient separation of tungsten(VI and rhenium (VII on alumina were established. The distribution coefficients Kd for tungstate and perrhenate anions, as well as the separation factors a (a = KdWO42-/Kd ReO4- were determined using hydrochloric or nitric acid as the aqueous media. A solution of sodium chloride in the pH range 2–6 was also examined. Under all the tested experimental conditions, alumina is a much better adsorbent for tungsten than for rhenium. The obtained results indicated that the best separation of these two elements is achieved when 0.01– 0.1 mol dm-3 HCl or 1.0 mol dm-3 HNO3 are used as the aqueous media. If NaCl is used as the aqueous phase, the best separation is achieved with 0.20 mol dm-3 NaCl, pH 4–6. Under these experimental conditions, the breakthrough and saturation capacities of alumina for tungsten at pH 4 are 17 and 26 mg W/g Al2O3, respectively. With increasing pH, these values decrease. Thus, at pH 6 they are only 4 and 13 mg W/g Al2O3, respectively.

  10. Separation of Rhenium from Lead-Rich Molybdenite Concentrate via Hydrochloric Acid Leaching Followed by Oxidative Roasting

    Directory of Open Access Journals (Sweden)

    Guanghui Li

    2016-11-01

    Full Text Available Lead-rich molybdenite is a typical rhenium-bearing molybdenum resource in China, which has not been efficiently utilized due to its high contents of lead and gangue minerals. In this study, hydrochloric acid was used for preliminarily removing lead and calcite from a lead-rich molybdenite concentrate. Oxidative roasting-ammonia leaching was then carried out for separation of rhenium and extraction of molybdenum. The hydrochloric acid leaching experiments revealed that 93.6% Pb and 97.4% Ca were removed when the leaching was performed at 95 °C for 10 min with HCl concentration of 8 wt. % and liquid-solid ratio of 5 (mL/g. The results of direct oxidative roasting indicated that 89.3% rhenium was volatilized from the raw concentrate after roasting at 600 °C for 120 min in air. In contrast, the rhenium volatilization was enhanced distinctly to 98.0% after the acid-leached concentrate (leaching residue was roasted at 550 °C for 100 min. By the subsequent ammonia leaching, 91.5% molybdenum was leached out from the calcine produced from oxidative roasting of the acid-leached concentrate, while only 79.3% Mo was leached from the calcine produced by roasting molybdenite concentrate without pretreatment.

  11. Effect of operational parameters and internal recycle on rhenium solvent extraction from leach liquors using a mixer-settler

    Directory of Open Access Journals (Sweden)

    Mostafa Hosseinzadeh

    2014-06-01

    Full Text Available The extraction of rhenium from molybdenite roasting dust leach solution was performed using a mixer-settler extractor by tributyl phosphate (TBP diluted in kerosene as the extractant. In the single-stage extraction experiments, effect of the aqueous to organic phase ratios, Qa/Qo, and the number of extraction stages, N, on the rhenium extraction was studied. It was found that using the phase ratio of 1:1 in a two-stage extraction, 87.5% depletion of rhenium was obtained. The comparison of experimental results with the continuous co-current extraction showed a good agreement. The effect of internal recycle of organic phase was investigated in the phase ratio of 1:1 by changing the flow rate ratio of recycle-to-fresh organic phase, Qro/Qfo. The optimum performance was achieved in the phase ratio, Qro/Qfo, equal to 3:7. It was found that improvement in the performance of the mixer-settler for the rhenium-TBP system can be obtained in the phase ratio of 1:1when Qro/Qfo = 3:7.

  12. A Study on the Trapping Characteristics of Rhenium Oxide Using Ca(OH){sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae-Kyo; Eun, Hee-Chul; Choi, Jung-Hoon; Lee, Ki-Rak; Han, Seung-Youb; Park, Hwan-Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-01-15

    The objective of this study was to obtain basic data for trapping gaseous technetium (Tc) oxide generated from the voloxidation process in spent nuclear fuel pyroprocessing. Rhenium (Re) and Ca(OH){sub 2} were used as surrogates for the technetium and a trapping material, respectively. The trapping characteristics of rhenium oxide were investigated with changing temperatures and molar ratios of calcium (Ca) over rhenium, and the thermal behaviors of the trapping products were observed. The products following after the trapping test were identified as Ca(ReO{sub 4}){sub 2} and Ca{sub 5}Re{sub 2}O{sub 12}. The conversion to Ca{sub 5}Re{sub 2}O{sub 12} was preferred with increasing temperatures, and the trapping products were completely converted into Ca5Re2O12 under conditions exceeding 800 ℃, or when maintained at 750 ℃ for 4 hr. The trapping efficiency at a molar ratio of 2.5 (Ca:Re=5:2) was significantly superior to that at the molar ratio of 2.

  13. 40 CFR 192.03 - Monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Monitoring. 192.03 Section 192.03... of Residual Radioactive Materials from Inactive Uranium Processing Sites § 192.03 Monitoring. A groundwater monitoring plan shall be implemented, to be carried out over a period of time commencing upon...

  14. sup(99m)Tc-sulfur-rhenium-colloid and 111In-indiumcitrate in the bone marrow scintigraphy

    International Nuclear Information System (INIS)

    Glaubitt, D.; Haberland, K.; Knoch, K.; Fejer, F.L.; Zachariah, S.; Staedtische Krankenanstalten Krefeld

    1975-01-01

    Bone marrow scintigraphy using 111 In-Indium-citrate and sup(99m)Tc-sulfur rhenium colloid was compared with each other in 6 male and 3 female patients. Our results in all patients were in favour of 111 In-citrate which caused a better delineation of morphological details than sup(99m)Tc-sulfur rhenium colloid did. In the first days after intravenous administration of 111 In-citrate, radioindium accumulated markedly in the pudendal region, this finding being more distinct in male patients than in female ones. On account of these results a considerable radiation dose has to be assumed in bone marrow scintigraphy using 111 In-citrate as long as the absorbed dose from 111 In has not been estimated under consideration of the radioindium accumulation in the pudendal region. 111 In-citrate should be applied in bone marrow scanning only exceptionally and sup(99m)Tc-sulfur rhenium colloid be preferred in the routine diagnostics of bone marrow. (orig.) [de

  15. 49 CFR 192.151 - Tapping.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Tapping. 192.151 Section 192.151 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.151 Tapping. (a) Each mechanical fitting used to make a hot tap must be designed for at least the operating pressure of...

  16. 22 CFR 192.52 - Disability benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Disability benefits. 192.52 Section 192.52... Disability or Death § 192.52 Disability benefits. (a) Principals who qualify for benefits under § 192.1 and... benefits may not be received from both OWCP and the local organizational authority for the same claim...

  17. Therapeutic applications of Rhenium-188 in nuclear medicine and oncology - Current status and expected future perspectives

    International Nuclear Information System (INIS)

    Knapp, F. F. Jr.

    2005-01-01

    Full text: The increasing use of unsealed radioactive targeting agents for cancer treatment requires the routine availability of cost-effective radioisotopes. Rhenium-188 (Re-188; half-life 16.9 hours) is a high-energy beta-emitter (E max 2.12 MeV), readily available no- max carrier-added from the alumina-based tungsten-188 (half-life 69 days)/rhenium-188 generator system. Rhenium-188 also emits a 155 keV (15%) gamma photon, permitting gamma camera imaging for biodistribution and dosimetry evaluation. The versatile chemistry of rhenium allows attachment to a wide variety of targeting molecules for Re-188 applications in nuclear oncology for both palliative metastatic treatment and targeted tumor therapy - radionuclide synovectomy, and coronary restenosis therapy. The long parent half-life and consistent performance provide an indefinite generator shelf-life of several months with high Re-188 elution yields (75-85 %) and consistently low W-188 parent breakthrough ( -6 ). Simple post-elution concentration methods have been developed which provide very high specific volume solution of Re-188 for radiolabeling (> 700 mCi/mL saline/1 Ci generator). Over 60 physician-sponsored clinical trials are currently in progress worldwide with applications in nuclear medicine, nuclear oncology and interventional cardiology. A variety of Re-188-labeled therapeutic radiopharmaceuticals and devices are being developed for clinical trials currently in progress for treatment of both benign and metastatic oncological disorders. Palliation of metastatic bone pain with Re-188-HEDP - prepared from a simple 'kit' - has been demonstrated as a cost-effective alternative to similar agents. Recent studies have in fact demonstrated the enhancement of progression-free interval and survival time by repeated Re-188-HEDP injections to patients with metastatic disease from prostate cancer. The use of the Re-188-labeled antiNCA95 (CD66) antibody in conjunction with external beam irradiation is an

  18. Effect of deformation and annealing on mechanical properties of nickel-rhenium alloys

    International Nuclear Information System (INIS)

    Mashkova, V.M.

    1978-01-01

    Studied have been the mechanical properties of nickel-rhenium alloys, depending on the extent of deformation and heat treatment leading to softening. The mechanical properties of the alloys have been estimated by the results of the tensile tests of wire samples. The softening of the alloy at different temperatures is judged about by the variation in hardness. The results of the study indicate that the most abrupt reduction in the hardness of the cold-hardened metal occurs at 900-1,000 deg C and the hold-time of 1 min. Increase in the hold-time at such temperature almost does not reduce the hardness. It is established that in order to soften nickel-rhenium alloys in the process of the cold-deformation at brief annealings in the air the hold-time should not exceed 5 min at 800-900 deg C

  19. Highvalent and organometallic technetium and rhenium compounds

    International Nuclear Information System (INIS)

    Oehlke, Elisabeth

    2010-01-01

    Diagnostic methods in nuclear medicine allow a detailed description of morphological organ structures and their function. The beta emitting isotope Tc-99 has optimal physical properties (140 keV gamma rays, half-life 6 h) and is therefore used for radiopharmaceuticals. The thesis is concerned with the search for new technetium complexes and their reproducible production. The (TcO3) core is of main interest. The second part of the thesis deals with organometallic technetium and rhenium complexes with carbonyl ligands and N-heterocyclic carbenes that show stability in aerobic aqueous solutions.

  20. Dicty_cDB: SFK192 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 2F (Link to Original site) Representative DNA sequence >SFK192 (SFK192Q) /CSM/SF/SFK1-D/SFK192Q.Seq.d/ CTTATCCACATANA... 4.0 %: vesicles of secretory system >> prediction for SFK192 is nuc 5' end seq. ID SFK192F 5' end seq. >SFK192F.Seq CTTATCCACATANA

  1. Study on the application of crown ether for neutron activation analysis of rubidium and rhenium in rock samples

    International Nuclear Information System (INIS)

    Wang Xiaolin; Fu Yibei; Liu Yinong; Xiong Zonghua; Hao Fanhua

    1996-01-01

    The extraction behaviour of rubidium and rhenium with 18-crown-6 (18C6) and benzo-15-crown-5 (B15C5) in nitrobenzene from picric acid or potassium hydroxide solution are studied and methods for separation and determination are developed. The molar ratio of 18C6 to Rb and B15C5 to Re in the extracted species is probably 2:1. Rubidium and rhenium in rock samples are satisfactorily determined by neutron activation method

  2. Femtosecond Fluorescence and Intersystem Crossing in Rhenium(I) Carbonyl-Bipyridine Complexes

    Czech Academy of Sciences Publication Activity Database

    Cannizzo, A.; Blanco-Rodríguez, A. M.; Nahhas, A. E.; Šebera, Jakub; Záliš, Stanislav; Vlček, Antonín; Chergui, M.

    2008-01-01

    Roč. 130, č. 28 (2008), s. 8967-8974 ISSN 0002-7863 R&D Projects: GA MŠk 1P05OC068 Institutional research plan: CEZ:AV0Z40400503 Keywords : rhenium(I) * carbonyl-bipyridine * intersystem crossing Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 8.091, year: 2008

  3. Molecular Engineering of Technetium and Rhenium Based Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zubieta, J.

    2003-01-01

    The research was based on the observation that despite the extraordinarily rich coordination chemistry of technetium and rhenium and several notable successes in reagent design, the extensive investigations by numerous research groups on a variety of N 2 S 2 and N 3 S donor type ligands and on HYNIC have revealed that the chemistries of these ligands with Tc and Re are rather complex, giving rise to considerable difficulties in the development of reliable procedures for the development of radiopharmaceutical reagents

  4. Rhenium(V) complexing with benzimidazole in acidic media

    International Nuclear Information System (INIS)

    Zakaeva, R.Sh.; Gagieva, S.Ch.; Kaloev, N.I.; Bukov, N.N.; Panyushkin, V.T.

    2003-01-01

    Coordination compounds of rhenium(V) with 1H-benzimidazole (L) separated from acid media: (HL) 2 [ReOX 5 ](H 2 O) n and [ReOL x X y (H 2 O) z ](H 2 O) n (HL and L - protonated and deprotonated forms of benzimidazole; X = Cl - , Br - ) were studied by the methods of IR spectroscopy, 1 H NMR spectroscopy and thermal gravimetric analysis. Methods of ligand coordination in the complexes are discussed on the basis of data obtained [ru

  5. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  6. 49 CFR 192.225 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  7. 22 CFR 192.31 - Applicable benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Applicable benefits. 192.31 Section 192.31 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Medical Benefits for Captive Situations § 192.31 Applicable benefits. A person eligible for benefits under this part...

  8. 49 CFR 192.16 - Customer notification.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer notification. 192.16 Section 192.16... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS General § 192.16 Customer notification. (a) This section applies to each operator of a service line who does not maintain the customer's buried piping up...

  9. 49 CFR 192.243 - Nondestructive testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Nondestructive testing. 192.243 Section 192.243... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.243 Nondestructive testing. (a) Nondestructive testing of welds must be performed by any process, other than trepanning, that...

  10. 22 CFR 192.11 - Applicable benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Applicable benefits. 192.11 Section 192.11 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Payment of Salary and Other Benefits for Captive Situations § 192.11 Applicable benefits. (a) Captives are entitled to...

  11. 22 CFR 192.51 - Death benefit.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Death benefit. 192.51 Section 192.51 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Compensation for Disability or Death § 192.51 Death benefit. (a) The Secretary of State or Agency Head may provide for payment...

  12. Experimental study and nuclear model calculations on the $^{192}Os (p, n)^{192}$Ir reaction Comparison of reactor and cyclotron production of the therapeutic radionuclide $^{192}$Ir

    CERN Document Server

    Hilgers, K; Sudar, S; 10.1016/j.apradiso.2004.12.010

    2005-01-01

    In a search for an alternative route of production of the important therapeutic radionuclide /sup 192/Ir (T/sub 1/2/=78.83 d), the excitation function of the reaction /sup 192/Os(p, n)/sup 192/Ir was investigated from its threshold up to 20MeV. Thin samples of enriched /sup 192/Os were obtained by electrodeposition on Ni, and the conventional stacked-foil technique was used for cross section measurements. The experimental data were compared with the results of theoretical calculations using the codes EMPIRE-II and ALICE-IPPE. Good agreement was found with EMPIRE-II, but slightly less with the ALICE-IPPE calculations. The theoretical thick target yield of /sup 192/Ir over the energy range E/sub p/=16 to 8MeV amounts to only 0.16MBq/ mu A.h. A comparison of the reactor and cyclotron production methods is given. In terms of yield and radionuclidic purity of /sup 192/Ir the reactor method appears to be superior; the only advantage of the cyclotron method could be the higher specific activity of the product.

  13. 22 CFR 192.21 - Applicable benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Applicable benefits. 192.21 Section 192.21... Soldiers' and Sailors' Civil Relief Act to Captive Situations § 192.21 Applicable benefits. (a) Eligible persons are entitled to the benefits provided by the Soldiers' and Sailors' Civil Relief Act of 1940 (50 U...

  14. Rhenium(V) complexes with sulfur-containing amino acids

    International Nuclear Information System (INIS)

    Gagieva, S.Ch.; Tautieva, M.A.; Tsaloev, A.T.; Galimov, Yu.B.; Gagieva, L.Ch.; Belyaeva, T.N.

    2007-01-01

    Rhenium(V) complexes with 2-amino-4-(methylthio)butanoic acid (methionine, Met) and 2-amino-3-sulfopropionic acid (cysteine, Cys) have been synthesized. Depending on the initial reagent ratio, the resulting complexes contain one or two ligand molecules. On heating the compounds with one amino acid molecule, two hydrogen halide molecules are removed at 128-132 deg C to form a molecular complex. The composition, structure, and thermal stability of the complexes have been studied by elemental analysis, conductometry, IR spectroscopy, NMR, and mass spectrometry [ru

  15. THERMIONIC EMISSION ENHANCEMENT FROM CESIUM COATED RHENIUM IN ELECTRIC FIELDS

    Energy Technology Data Exchange (ETDEWEB)

    de Steese, J. G.; Zollweg, R. J.

    1963-04-15

    The plasma-anode technique was used to observe anomalously high thermionic emission from a rhenium surface with small cesium coverage, where the work function of the composite surface is greater than the ionization potential of cesium. Data suggest that emission enhancement is caused by increased cesium coverage because of cesiumion trapping near the emitter surface under the influence of an ion-rich sheath. (auth)

  16. Lattice strains in gold and rhenium under nonhydrostatic compression to 37 GPa

    International Nuclear Information System (INIS)

    Duffy, Thomas S.; Shen, Guoyin; Heinz, Dion L.; Shu, Jinfu; Ma, Yanzhang; Mao, Ho-Kwang; Hemley, Russell J.; Singh, Anil K.

    1999-01-01

    Using energy-dispersive x-ray diffraction techniques together with the theory describing lattice strains under nonhydrostatic compression, the behavior of a layered sample of gold and rhenium has been studied at pressures of 14-37 GPa. For gold, the uniaxial stress component t is consistent with earlier studies and can be described by t=0.06+0.015P where P is the pressure in GPa. The estimated single-crystal elastic moduli are in reasonable agreement with trends based on extrapolated low-pressure data. The degree of elastic anisotropy increases as α, the parameter which characterizes stress-strain continuity across grain boundaries, is reduced from 1.0 to 0.5. For rhenium, the apparent equation of state has been shown to be strongly influenced by nonhydrostatic compression, as evidenced by its dependence on the angle ψ between the diffracting plane normal and the stress axis. The bulk modulus obtained by inversion of nonhydrostatic compression data can differ by nearly a factor of 2 at angles of 0 degree sign and 90 degree sign . On the other hand, by a proper choice of ψ, d spacings corresponding to quasihydrostatic compression can be obtained from data obtained under highly nonhydrostatic conditions. The uniaxial stress in rhenium over the pressure range from 14-37 GPa can be described by t=2.5+0.09P. The large discrepancy between x-ray elastic moduli and ultrasonic data and theoretical calculations indicates that additional factors such as texturing or orientation dependence of t need to be incorporated to more fully describe the strain distribution in hexagonal-close-packed metals. (c) 1999 The American Physical Society

  17. Intracellular distribution and stability of a luminescent rhenium(I) tricarbonyl tetrazolato complex using epifluorescence microscopy in conjunction with X-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Wedding, Jason L.; Harris, Hugh H.; Bader, Christie A.; Plush, Sally E.; Mak, Rachel

    2016-01-01

    Optical fluorescence microscopy was used in conjunction with X-ray fluorescence microscopy to monitor the stability and intracellular distribution of the luminescent rhenium(I) complex fac-[Re(CO) 3 (phen)L], where phen = 1,10-phenathroline and L = 5-(4-iodophenyl)tetrazolato, in 22Rv1 cells. The rhenium complex showed no signs of ancillary ligand dissociation, a conclusion based on data obtained via X-ray fluorescence imaging aligning iodine and rhenium distributions. A diffuse reticular localisation was detected for the complex, in the nuclear/perinuclear region of cells, by either optical or X-ray fluorescence techniques. Furthermore, X-ray fluorescence also showed that the Re-I complex disrupted the homeostasis of some biologically relevant elements, such as chlorine, potassium and zinc.

  18. Effect of the method for rhenium neptasulfide preparation on its catalytic properties in hydrogenation of nitrobenzene and m-nitrobenzoic acid

    International Nuclear Information System (INIS)

    Pal'chevskaya, T.A.; Bogutskaya, L.V.; Belousov, V.M.

    1988-01-01

    The effect of conditions of rhenium heptasulfide synthesis by thiosulfate method on its physicochemical and catalytic properties during hydrogenation of nitrobenzene and m-nitrobenzoic acid has been studied. It is shown that the maximum yield of m-aminobenzoic acid can be attained on insoluble sulfide rhenium contacts, containing excessive amount of sulfur (3.5 %). Under certain conditions of catalyst synthesis particles of Re 2 S 7 soluble in dimethylformamide are formed, which possess selectivity towards amine

  19. 49 CFR 192.377 - Service lines: Copper.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Copper. 192.377 Section 192.377 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... § 192.377 Service lines: Copper. Each copper service line installed within a building must be protected...

  20. Studies of technetium chemistry. Pt.8. The regularities of the bond length and configuration of rhenium and technetium complexes in crystals

    International Nuclear Information System (INIS)

    Liu Guozheng; Liu Boli

    1995-01-01

    Some bond length regularities in MO 6 , MO-4, MX 5 α and MX 4 αβ moieties of technetium and rhenium compounds are summarized and rationalized by cavity model. The chemical properties of technetium and rhenium are so similar that their corresponding complexes have almost the same configuration and M-X bond lengths when they are in cavity-controlled state. Technetium and Rhenium combine preferably with N, O, F, S, Cl and Br when they are in higher oxidation states (>3), but preferably with P, Se etc. when they are in lower oxidation states ( 4 αβ is approximately constant; (2) the average M-X bond length of MX 6 varies moderately with the oxidation state of M; (3) the bond length of M-X trans to M-α in MX 5 α has a linear relationship with the angle

  1. 49 CFR 192.311 - Repair of plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Repair of plastic pipe. 192.311 Section 192.311... Lines and Mains § 192.311 Repair of plastic pipe. Each imperfection or damage that would impair the serviceability of plastic pipe must be repaired or removed. [Amdt. 192-93, 68 FR 53900, Sept. 15, 2003] ...

  2. 49 CFR 192.121 - Design of plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Design of plastic pipe. 192.121 Section 192.121... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Pipe Design § 192.121 Design of plastic pipe. Subject to the limitations of § 192.123, the design pressure for plastic pipe is determined by either of the...

  3. 22 CFR 192.33 - Dispute.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Dispute. 192.33 Section 192.33 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Medical Benefits for Captive... Director, Department of State, for a determination. If the person bringing the claim is not satisfied with...

  4. 22 CFR 192.41 - Applicable family benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Applicable family benefits. 192.41 Section 192.41 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Educational... circumstances and within the limitation of § 192.44, the Secretary of State, under the criteria and procedures...

  5. Neutron activation determination of rhenium in mineral raw materials of complex composition

    International Nuclear Information System (INIS)

    Shiryaeva, M.B.; Lyubimova, L.N.; Salmin, Yu.P.; Ryumina, K.N.; Tatarkin, M.A.

    1984-01-01

    The method of neutron-activation rhenium determination in mineral raw material of complex composition is developed, according to which easily hydrolized elements: scandium, iron, lanthanum, ytterbium, protactinium, hafnium and partially ruthenium and osmium are isolated in the form of hydroxides after smelting of a sample, which has been previously irradiated in nuclear reactor (thermal neutron flux 1.2x10 13 n/cm 2 xs for 22 hr) with sodium peroxide and leaching of the melt by water. To separate Re from other interfering elements extraction of perrhenate-ion by methylethylketone from alkali solution is used. Interfering effect of gold is eliminated by its extraction with TBP 30% solution in toluence or benzene from 1 M HNO 3 . Activity of rhenium preparations, singled out from samples of comparison, is measured, using multichannel γ-spectrometer with Ge(Li)-coaxial detector of high resolution (approximately 2.0-2.2 keV over the line 122 keV 5+ Co). Relative standard deviation in Re content range 5x10 -7 -5x10 -2 % does not exceed 0.3

  6. 49 CFR 192.235 - Preparation for welding.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Preparation for welding. 192.235 Section 192.235... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.235 Preparation for welding. Before beginning any welding, the welding surfaces must be clean and free of any material that...

  7. 50 CFR 19.2 - Scope of regulations.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Scope of regulations. 19.2 Section 19.2... PLANTS (CONTINUED) AIRBORNE HUNTING Introduction § 19.2 Scope of regulations. The regulations contained... United States citizens whether within the territorial jurisdiction of the United States or on the high...

  8. 49 CFR 192.11 - Petroleum gas systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Petroleum gas systems. 192.11 Section 192.11... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS General § 192.11 Petroleum gas systems. (a) Each plant that supplies petroleum gas by pipeline to a natural gas distribution system must meet the requirements...

  9. Activity uniformity of Ir-192 seeds

    International Nuclear Information System (INIS)

    Ling, C.C.; Gromadzki, Z.C.

    1981-01-01

    A simple device that uses materials and apparatus commonly available in a radiotherapy department has been designed, fabricated and used in routine quality control relative to the activity uniformity of clinical Ir-192 seeds in ribbons. Detailed evaluation indicated that this system is easy to use and can yield relative activity measurements of individual Ir-192 seeds accurate to within 2%. With this device, activity uniformity of commercial Ir-192 seeds from two manufacturers has been assessed. For the seven shipments of Ir-192 seeds studied, the root mean square variations of individual seed strength from the average of each shipment ranged from 3.4 to 7.1%. Variation in seed activity by more than +- 10% from the average is not uncommon

  10. Liquid kit for preparation of 188rhenium-etidronate

    International Nuclear Information System (INIS)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    The aim of this study was the preparation of a liquid kit for radiolabeling of 188 Re-HEDP (hydroxyethylidene diphosphonate). 188 Re was obtained from alumina based 188 W/ 188 Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of 188 Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  11. Cermets based on rhenium and rare earth element oxides

    International Nuclear Information System (INIS)

    Varfolomeev, M.B.; Velichko, A.V.; Zajtseva, L.L.; Shishkov, N.V.

    1977-01-01

    The reduction of perrhenates of rare earth elements and of yttrium by hydrogen and the subsequent sintering have yielded cermets based on rhenium and rare earth element oxides inherent in which are more disperse and homogeneous structures than those of the ''molecular'' rare earth element-Tc cermets. The dispersity of cermets increases in the rare earth elements series from La to Lu. The microhardness of the Re phase in cermets is 490 kgf/mm 2 ; the total microhardness of a cermet is substantially higher

  12. 22 CFR 192.5 - Relationships among agencies.

    Science.gov (United States)

    2010-04-01

    ... inform the head of any agency whenever an employee of that agency, or Family Member of such employee, is... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Relationships among agencies. 192.5 Section 192... § 192.5 Relationships among agencies. (a) To assist in ensuring that eligible persons receive...

  13. 49 CFR 192.375 - Service lines: Plastic.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Plastic. 192.375 Section 192.375... § 192.375 Service lines: Plastic. (a) Each plastic service line outside a building must be installed... terminate above ground level and outside the building, if— (i) The above ground level part of the plastic...

  14. Endocavitary treatment of craniopharyngioma cysts by 186-rhenium. Traitement endocavitaire par le rhenium 186 des kystes de craniopharyngiomes

    Energy Technology Data Exchange (ETDEWEB)

    Berenger, N.; Lebtahi, R.; Piketty, M.L.; Merienne, L.; Turak, B.; Bok, R.; Askienazy, S. (Hopital Sainte-Anne, 75 - Paris (France)); Munari, C. (Centre Hospitalier Universitaire, 38 - Grenoble (France))

    1993-01-01

    Forty-three patients with craniopharyngioma cysts were treated by intracystic injection of 186-rhenium. Leakage of colloid isotope into the CSF spaces during the ''test'' or ''therapeutic'' injection was detected by scintigraphic follow-up (15 cases/58 intracystic injections). In fact the physical characteristics of [sup 186]Re are well adapted to the requirements of treatment and, with the gamma emission, also allows early detection of leakage, avoiding irradiation of neighbouring structures. Follow-up studies revealed that craniopharyngioma cysts were effectively treated, with cessation of fluid formation, progressive shrinkage of the cysts leading to total disappearance in 14 cases (10-156 months, mean 52.5) and a considerable decrease in 13 cases (5-53 months, mean 23).

  15. Diverse roles of hydrogen in rhenium carbonyl chemistry: hydrides, dihydrogen complexes, and a formyl derivative.

    Science.gov (United States)

    Li, Nan; Xie, Yaoming; King, R Bruce; Schaefer, Henry F

    2010-11-04

    Rhenium carbonyl hydride chemistry dates back to the 1959 synthesis of HRe(CO)₅ by Hieber and Braun. The binuclear H₂Re₂(CO)₈ was subsequently synthesized as a stable compound with a central Re₂(μ-H)₂ unit analogous to the B₂(μ-H)₂ unit in diborane. The complete series of HRe(CO)(n) (n = 5, 4, 3) and H₂Re₂(CO)(n) (n = 9, 8, 7, 6) derivatives have now been investigated by density functional theory. In contrast to the corresponding manganese derivatives, all of the triplet rhenium structures are found to lie at relatively high energies compared with the corresponding singlet structures consistent with the higher ligand field splitting of rhenium relative to manganese. The lowest energy HRe(CO)₅ structure is the expected octahedral structure. Low-energy structures for HRe(CO)(n) (n = 4, 3) are singlet structures derived from the octahedral HRe(CO)₅ structure by removal of one or two carbonyl groups. For H₂Re₂(CO)₉ a structure HRe₂(CO)₉(μ-H), with one terminal and one bridging hydrogen atom, lies within 3 kcal/mol of the structure Re₂(CO)₉(η²-H₂), similar to that of Re₂(CO)₁₀. For H₂Re₂(CO)(n) (n = 8, 7, 6) the only low-energy structures are doubly bridged singlet Re₂(μ-H)₂(CO)(n) structures. Higher energy dihydrogen complex structures are also found.

  16. Complexes of technetium, rhenium, and rhodium with sexidentate Schiff-base ligands

    International Nuclear Information System (INIS)

    Hunter, G.; Kilcullen, N.

    1989-01-01

    The monocationic technetium (IV) and rhenium (IV) complexes with the sexidentate Schiff-base ligands tris[2-(2'-hydroxybenzylideneethyl)]amine and its substituted derivatives have been prepared and their electrochemical properties studied. The variable-temperature 90.6 MHz 13 C-{ 1 H} n.m.r. spectrum of the rhodium (III) complex of tris[2-(2-hydroxy-5'-isopropylbenzylideneethyl)-amine] has been observed, indicating fluxionality at temperatures above 218 K. (author)

  17. Analysis of the Nuclear Structure of Rhenium-186 Using Neutron-Induced Reactions

    Science.gov (United States)

    2015-03-26

    5 1.5 Methods ... radioisotope power source for use on the battlefield. 1 Re-Os Cosmochronometer. The isotope 187Re has a half-life in its ground state of 4.35⇥ 1010 years [2...187Os in meteorites permits one to date the nucleosynthesis of rhenium and osmium by high neutron flux events such as supernovae. The Re-Os radioactive

  18. 49 CFR 192.287 - Plastic pipe: Inspection of joints.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Plastic pipe: Inspection of joints. 192.287... Than by Welding § 192.287 Plastic pipe: Inspection of joints. No person may carry out the inspection of joints in plastic pipes required by §§ 192.273(c) and 192.285(b) unless that person has been qualified by...

  19. Rhenium-catalyzed dehydrogenative olefination of C(sp(3))-H bonds with hypervalent iodine(III) reagents.

    Science.gov (United States)

    Gu, Haidong; Wang, Congyang

    2015-06-07

    A dehydrogenative olefination of C(sp(3))-H bonds is disclosed here, by merging rhenium catalysis with an alanine-derived hypervalent iodine(III) reagent. Thus, cyclic and acyclic ethers, toluene derivatives, cycloalkanes, and nitriles are all successfully alkenylated in a regio- and stereoselective manner.

  20. 49 CFR 192.321 - Installation of plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Installation of plastic pipe. 192.321 Section 192... Transmission Lines and Mains § 192.321 Installation of plastic pipe. (a) Plastic pipe must be installed below ground level except as provided by paragraphs (g) and (h) of this section. (b) Plastic pipe that is...

  1. 49 CFR 192.125 - Design of copper pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Design of copper pipe. 192.125 Section 192.125... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Pipe Design § 192.125 Design of copper pipe. (a) Copper... hard drawn. (b) Copper pipe used in service lines must have wall thickness not less than that indicated...

  2. New extraction chromatographic material for rhenium separation

    International Nuclear Information System (INIS)

    Lucanikova, M.; Czech Technical University, Prague; Kucera, J.; Czech Technical University, Prague; Sebesta, F.

    2008-01-01

    Three types of the extraction chromatographic materials, composed from Aliquat R 336 deposited in the polyacrylonitrile (PAN) beads and prepared by different procedures, were compared for extraction of rhenium. The best properties were exhibited when the solid extractant was prepared by impregnation of the ready-made PAN beads. Solid extractant prepared by direct coagulation of the beads from the suspension of Aliquat R 336 in solution of PAN in nitric acid differs only by lower capacity in dynamic conditions. Material prepared from the PAN solution in dimethylsulfoxide was the worst because Aliquat R 336 was washed out from the beads during coagulation of the polymer and the extraction capacity was low. As it is shown, the first two solid extractants are fully comparable with the commercial TEVA Resin. (author)

  3. Synthesis and physicochemical characterization of rhenium (V) complexes with bisbenzoylthiosemicarbazones

    International Nuclear Information System (INIS)

    Gagieva, S.Ch.; Gutnova, N.A.; Tsaloev, A.T.; Khubulov, A.B.; Arutyunyants, A.A.; Galimov, Yu.B.

    2003-01-01

    Rhenium (V) complexing with mono- and bis-benzoylthiosemicarbazones is studied in dependence on hydrohalic acids concentration changes. It is determined that in media with high concentration of hydrohalic acids (6 mol/l HCl, 7 mol/l HBr) in dependence on reaction conditions stable complexes with bi- and tridentate coordination of thiosemicarbazone are formed. In the case of hydrohalic acid concentration decreasing stable binuclear and oxohydroxycomplexes are formed. Composition and structure of the compounds obtained are determined by the methods of element analysis, IR spectroscopy, conductometry. Thermal investigations of the compounds obtained are done [ru

  4. The process development of laser surface modification of commercially pure titanium (Grade 2) with rhenium

    Science.gov (United States)

    Kobiela, K.; Smolina, I.; Dziedzic, R.; Szymczyk, P.; Kurzynowski, T.; Chlebus, E.

    2016-12-01

    The paper presents the results of the process development of laser surface modification of commercially pure titanium with rhenium. The criterion of the successful/optimal process is the repetitive geometry of the surface, characterized by predictable and repetitive chemical composition over its entire surface as well as special mechanical properties (hardness and wear resistance). The analysis of surface geometry concluded measurements of laser penetration depth and heat affected zone (HAZ), the width of a single track as well as width of a clad. The diode laser installed on the industrial robot carried out the laser treatment. This solution made possible the continuous supply of powder to the substrate during the process. The aim of an investigation is find out the possibility of improving the tribological characteristics of the surface due to the rhenium alloying. The verification of the surface properties (tribological) concluded geometry measurements, microstructure observation, hardness tests and evaluation of wear resistance.

  5. Rhenium-186 direct labelling HIgG

    International Nuclear Information System (INIS)

    Lungu, V.; Mihailescu, G.; Dumitrescu, G.

    2001-01-01

    The aim of this study is to develop and improve existing radiolabelling techniques of peptides and monoclonal antibodies with 186 Re for achievement of potential agents for cancer targeted radiotherapy. There were selected methods and techniques for the direct labelling of intact HIgG by studding chemical and radiochemical processes of -S-S- bridges prereduction, reduction of 186 ReO 4 - and coupling reaction of rhenium with HIgG. The -S-S- bridges prereduction of HIgG to sulfhydryls was effected using different reducing agents: ascorbic acid, 2,3 dimercaptopropanol, cysteine, active hydrogen. The prereduction reactions are controlled by masic ratios of HIgG/reduction agent, pH, temperature and time of incubation. A pH=4.5 and a 24 hours incubation time are in the advantage of the prereduction yield. The labelling with 186 Re of prereduced HIgG with ascorbic acid or active hydrogen and 37 deg. C incubation in 22 hours releases 92% radiochemical purity. (author)

  6. Liquid kit for preparation of {sup 188}rhenium-etidronate

    Energy Technology Data Exchange (ETDEWEB)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), SP (Brazil). Centro de Radiofarmacia]. E-mail: baszot@gmail.com

    2005-10-15

    The aim of this study was the preparation of a liquid kit for radiolabeling of {sup 188} Re-HEDP (hydroxyethylidene diphosphonate). {sup 188} Re was obtained from alumina based {sup 188} W/{sup 188} Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of {sup 188} Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  7. Kinetics and mechanism of nitrobenzene hydrogenation to phenylhydroxylamine in rhenium thiocomplexes solutions

    International Nuclear Information System (INIS)

    Korenyako, G.I.; Belousov, V.M.

    1985-01-01

    A study was made on kinetics of nitrobenzene hydrogenation to phenylhydroxylamine in dimethylformamide solutions of rhenium thiocomplexes. The mechanism of hydrogenation was suggested. Formation of hydride catalyst complex represents the first stage of the process. Kinetic equation derived on the basis of suggested mechanism corresponds satisfactorily with experimental results. Thermodynamic parameters of separate process stages calculated on the basis of equilibrium constant values testify as well to the benefit of suggested mechanism

  8. Formamidine sulfinic acid as reducing agent in technetium-99m rhenium sulfide labelling

    Energy Technology Data Exchange (ETDEWEB)

    Neves, M; Patricio, L [Laboratorio Nacional de Engenharia e Technologia Industrial, Sacavem (Portugal). Dept. de Radioisotopes; Ferronha, H [Laboratorio Nacional de Investigacao Veterinaria, Lisboa (Portugal)

    1989-08-01

    Labelling kinetic studies, radiochemical characterization and particle size evaluation of {sup 99m}Tc rhenium sulfide colloid using formamidine sulfinic acid as reducing agent are described. Comparison with the same colloid which makes use of Sn-sodium pyrophosphate complex as reducing agent showed higher labelling yields, simplification of labelling procedure and a longer shelf life when formamidine sulfinic acid was used. (author) 15 refs.; 7 figs.

  9. 49 CFR 192.191 - Design pressure of plastic fittings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Design pressure of plastic fittings. 192.191... Components § 192.191 Design pressure of plastic fittings. (a) Thermosetting fittings for plastic pipe must conform to ASTM D 2517, (incorporated by reference, see § 192.7). (b) Thermoplastic fittings for plastic...

  10. 49 CFR 192.231 - Protection from weather.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Protection from weather. 192.231 Section 192.231 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... weather. The welding operation must be protected from weather conditions that would impair the quality of...

  11. Use of new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-01-01

    In this paper we describe the first application of our simple and inexpensive post-elution tandem cation/anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical-scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine-type (QMA SepPak TM ) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator. (author)

  12. 22 CFR 192.40 - Eligibility for benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Eligibility for benefits. 192.40 Section 192.40 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Educational... programs of the Department of Veterans' Affairs under chapter 35 of title 38, United States Code). (b) A...

  13. 49 CFR 192.277 - Ductile iron pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Ductile iron pipe. 192.277 Section 192.277 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Ductile iron pipe. (a) Ductile iron pipe may not be joined by threaded joints. (b) Ductile iron pipe may...

  14. Paraoxonase 1 192 and 55 polymorphisms in osteosarcoma.

    Science.gov (United States)

    Ergen, Arzu; Kılıcoglu, Onder; Ozger, Harzem; Agachan, Bedia; Isbir, Turgay

    2011-08-01

    Paraoxonase is an HDL-associated enzyme that plays a preventive role against oxidative stres. Previous studies suggested that involved an amino acid substitution at position 192 gives rise to two alloenzymes with a low activity (Q allele) and a high activity (R allele) towards paraoxon. There also exists a second polymorphism of the human PON1 gene affecting amino acid 55, giving rise to a leucine (L-allele) substitution for methionine (M-allele). PON1 gene polymorphisms were studied in 50 patients with osteosarcoma and 50 healthy controls. Paraoxonase genotypes were determined by PCR-RFLP. We found a reduction in the frequency of PON1 192 R allele in patients (P=0.015). Besides, PON1 192 wild type QQ genotype (P=0.015) and PON1 55 wild type L allele (P=0.001) were higher in patients compared to healthy controls. PON1 192 QQ genotype was associated with osteosarcoma in multivariate logistic regression analysis. Our findings have suggested that PON1 192 wild type genotypes may be associated with a risk of developing osteosarcoma.

  15. Thermal decomposition of rhenium (5) complexes with 1,2,4-triazole

    International Nuclear Information System (INIS)

    Amindzhanov, A.A.; Gagieva, S.Ch.; Kotegov, K.V.

    1991-01-01

    Processes of thermal decomposition of rhenium (5) complexes with 1,2,4-triazole were studied. Thermolysis products were identified on the basis of data of the element analysis, IR spectra, conductometry and other methods. It is ascertained that at the first stage of thermolysis of hydroxyl-containing monomer complexes removal of water molecules occurs, and at the second one - dimerization process with formation of Re-O-Re group. It is shown that the nature of halide ion practically does not affect the temperature of the start of intensive thermal decomposition of the complexes

  16. The analysis of mechanism of rhenium-coated tools' wear-resistance rising

    Directory of Open Access Journals (Sweden)

    Daniel Petrosyan

    2017-06-01

    Full Text Available It is proposed to obtain wear-resistant layers on the hard-alloy materials by thermochemical treatment. In the different field of production – mechanical engineering, metallurgy and military technologies, with machine parts demanding high wearproof and corrosion-proof machinery parts on the surfaces of syntheses of diamonds, with metal surface thermal-diffusion with rhenium, to receive diffusion wearing layers for the first time. A method for thermochemical treatment of hard alloy plates has been investigated, allowing to raise the wear-resistance of cutting and mining tools.

  17. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    International Nuclear Information System (INIS)

    Huang, Yongle; Bai, Shuxin; Zhang, Hong; Ye, Yicong

    2015-01-01

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm 2 min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm 2 min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating

  18. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yongle; Bai, Shuxin, E-mail: NUDT_MSE_501@163.com; Zhang, Hong; Ye, Yicong

    2015-02-15

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm{sup 2} min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm{sup 2} min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating.

  19. High-resolution metallic magnetic calorimeters for β-spectroscopy on 187rhenium and position resolved X-ray spectroscopy

    International Nuclear Information System (INIS)

    Porst, Jan-Patrick

    2011-01-01

    This thesis describes the development of metallic magnetic calorimeters (MMCs) for high resolution spectroscopy. MMCs are energy dispersive particle detectors based on the calorimetric principle which are typically operated at temperatures below 100 mK. The detectors make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. The application of MMCs for neutrino mass measurements and their advantages with respect to other approaches are discussed. In view of this application the development of an MMC optimized for β-endpoint spectroscopy on 187 rhenium is presented. A fully micro-fabricated X-ray detector is characterized and performs close to design values. Furthermore, a new technique to more efficiently couple rhenium absorbers mechanically and thermally to the sensor was developed and successfully tested. By employing a metallic contact, signal rise times faster than 5 μs could be observed with superconducting rhenium absorbers. In addition to the single pixel detectors, an alternative approach of reading out multiple pixels was developed in this work, too. Here, the individual absorbers have a different thermal coupling to only one temperature sensor resulting in a distribution of different pulse shapes. Straightforward position discrimination by means of rise time analysis is demonstrated for a four pixel MMC and a thermal model of the detector is provided. Unprecedented so far, an energy resolution of less than ΔE FWHM <5 eV for 5.9 keV X-rays was achieved across all absorbers. (orig.)

  20. Studies of the structures of rhenium complexes with sulphur-containing amino acids: cysteine and homocysteine

    International Nuclear Information System (INIS)

    Arkowska, A.; Wojciechowski, W.

    1979-01-01

    Two rhenium compounds have been synthesized: compound 1 with cysteine HS-CH 2 -CH-NH 2 -COOH and compound 2 with homocysteine HS-CH 2 -CH 2 -CH-NH 2 -COOH. On the basis of spectroscopic measurements (IR, far IR, Raman, VIS and UV spectra) and magnetic susceptibility measurements their probable electronic and molecular structures have been determined. (author)

  1. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  2. 47 CFR 0.192 - Emergency Response Interoperability Center.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Emergency Response Interoperability Center. 0.192 Section 0.192 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMISSION ORGANIZATION..., industry representatives, and service providers. [75 FR 28207, May 20, 2010] ...

  3. 41 CFR 102-192.5 - What does this part cover?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What does this part cover? 102-192.5 Section 102-192.5 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT...

  4. Rhenium (5) and molybdenum (5) complexes with 4',4''(5'')-ditretbutyldibenzo-24-crown-8

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.; Basitova, S.M.; Tashmukhamedova, A.K.; Sajfullina, N.Zh.

    1989-01-01

    Rhenium and molybdenum complexes in +5 oxidation degree with 4',4''(5'')-ditretbutyldibenzo-24-crown-8 (L) are synthesized with 75-95 % yield. Composition and structure of compounds produced are investigated using element analysis, conductometry, IR spectroscopy, thermogravimetry methods. Oxidation degree of complexer metal is determined. It is ascertained that the compound composition corresponds to the MOLX 3 formula, where M-Re, Mo; X-Cl - , Br -

  5. Chalcogenhalide cluster rhenium- and molybdenum complexes

    International Nuclear Information System (INIS)

    Fedin, V.P.; Gubin, S.P.; Mishchenko, A.V.; Fedorov, V.E.

    1984-01-01

    The interaction of rhenium- and molybdenum chalcogenhalides with n-donor ligands (L) is studied. At heating Re 3 X 2 Hal 5 complexes up to 100 deg in DMSO in the L presence obtained are the complexes of the 1-6 composition Re 3 X 2 Hal 5 -x Lx DMSO (X=Se, Hal=Cl, L=Et 3 N(1); X=Se, Hal=Cl, L=Bipy(2); X=Se, Hal=Br, L=Et 3 N(3); X=Se, Hal=Br, L=Bipy(4); X=Te, Hal=Br, L=Et 3 N(5); X=Te, Hal=Br, L=(Me 2 NCH 2 ) 2 (6). In the course of boiling of Mo 3 S 7 Hal 4 with PPh 3 in MeCN the Mo 3 S 7 Hal 4 2PPh 3 complexes (Hal=Cl(7); Br(8)) are obtained. For 1 through 8 complexes the chemical analysis data and IR spectra are given. For 4 and 8 complexes the molecular mass is measured. A possible method of obtaining molecular trinuclear clusters from polymer clusters is discussed

  6. Traceable calibration of hospital 192Ir HDR sources

    International Nuclear Information System (INIS)

    Govinda Rajan, K.N.; Bhatt, B.C.; Pendse, A.M.; Kannan, V.

    2002-01-01

    Presently, no primary standard exists for the standardization of remote afterloading 192 Ir HDR sources. These sources are, therefore, being standardized by a few Secondary Standard Dosimetry Laboratories (SSDLs), in terms of Air Kerma Strength (AKS) or Reference Air Kerma Rate (RAKR) using a 0.6 cc Farmer type chamber, set up as an Interim Standard. These SSDLs offer calibration to well type of ionization chambers that are normally used by the hospitals for calibrating the 192 lr HDR source. Presently, in many countries, including India, well chambers are not commercially available. Nor do these countries offer any calibration service for 192 lr HDR source. With the result users make use of well chambers imported from different countries with their calibration traceable to the country of origin. Since no intercomparisons between these countries have been reported, the measurement consistency between hospitals becomes questionable. The problem is compounded by the fact that these chambers are used for several years without re-calibration since no calibration service is locally available. For instance, in India, the chambers have been in use in hospitals, since 1994, without a second calibration. Not all hospitals use the well chamber for the calibration of the 192 lr HDR source. Many hospitals make use of 0.6 cc chambers, in air, at short source to chamber distances, for measuring the AKS of the source. The latter method is prone to much larger inaccuracy due to the use of very short source to chamber distances without proper calibration jigs, use of 60 Co calibration factor for 192 Ir HDR source calibrations, neglecting correction factors for room scatter, fluence non-uniformity, use of arbitrary buildup factors for the buildup cap of the chamber etc. A comparison of the procedures used at hospitals revealed that various arbitrary methods are in use at hospitals. An indigenously developed well chamber was calibrated against a Reference Standard traceable to the

  7. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  8. 27 CFR 25.192 - Removal of sour or damaged beer.

    Science.gov (United States)

    2010-04-01

    ... beer. 25.192 Section 25.192 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Removals Without Payment of Tax Removal of Beer Unfit for Beverage Use § 25.192 Removal of sour or damaged beer. (a) Containers. The brewer shall remove sour or...

  9. 41 CFR 102-192.10 - What authority governs this part?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT Introduction to this Part § 102-192.10 What authority governs this part? This part is governed by... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What authority governs this part? 102-192.10 Section 102-192.10 Public Contracts and Property Management Federal Property...

  10. Convenient synthesis of bis(alkoxy)rhenium(VII) complexes

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Z.; Al-Ajlouni, A.M.; Espenson, J.H. [Iowa State Univ., Ames, IA (United States)

    1996-02-28

    The study of high-oxidation-state organorhenium compounds has been a field of continuing activity, thanks to the success of methylrhenium trioxide (CH{sub 3}ReO{sub 3} or MTO) in catalytic processes. This catalyst is effective in oxidations, olefin metathesis, the olefination of aldehydes, and the preparation of other compounds with three-membered rings. The syntheses of some rhenium compounds derived form MTO have been reported. Epoxide formation is a key reaction, and it bears directly on these findings reported here. Re(VII) complexes containing a chelated bis(diolate) ligand can be synthesized by refluxing MTO with 2,3-dimethyl-2,3-diol. Here, the authors report a more convenient method for this preparation. A different series of related compounds consists of chelated bis(diolates) of the Cp*Re-oxo series, Cp*ReO-(diolate).

  11. High-resolution metallic magnetic calorimeters for {beta}-spectroscopy on {sup 187}rhenium and position resolved X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Porst, Jan-Patrick

    2011-02-01

    This thesis describes the development of metallic magnetic calorimeters (MMCs) for high resolution spectroscopy. MMCs are energy dispersive particle detectors based on the calorimetric principle which are typically operated at temperatures below 100 mK. The detectors make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. The application of MMCs for neutrino mass measurements and their advantages with respect to other approaches are discussed. In view of this application the development of an MMC optimized for {beta}-endpoint spectroscopy on {sup 187}rhenium is presented. A fully micro-fabricated X-ray detector is characterized and performs close to design values. Furthermore, a new technique to more efficiently couple rhenium absorbers mechanically and thermally to the sensor was developed and successfully tested. By employing a metallic contact, signal rise times faster than 5 {mu}s could be observed with superconducting rhenium absorbers. In addition to the single pixel detectors, an alternative approach of reading out multiple pixels was developed in this work, too. Here, the individual absorbers have a different thermal coupling to only one temperature sensor resulting in a distribution of different pulse shapes. Straightforward position discrimination by means of rise time analysis is demonstrated for a four pixel MMC and a thermal model of the detector is provided. Unprecedented so far, an energy resolution of less than {delta}E{sub FWHM}<5 eV for 5.9 keV X-rays was achieved across all absorbers. (orig.)

  12. 22 CFR 192.4 - Notification of eligible persons.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Notification of eligible persons. 192.4 Section 192.4 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION General... of State, or other Agency Head in domestic situations, shall be responsible for notifying each...

  13. 49 CFR 192.477 - Internal corrosion control: Monitoring.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Monitoring. 192.477... Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons... internal corrosion. Each coupon or other means of monitoring internal corrosion must be checked two times...

  14. 7 CFR 3015.192 - Institutions of higher education.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Institutions of higher education. 3015.192 Section....192 Institutions of higher education. (a) OMB Circular No. A-21, including any amendments to the... activities conducted by institutions of higher education (other than for-profit institutions). (b) Additional...

  15. Comment: 192 [Taxonomy Icon

    Lifescience Database Archive (English)

    Full Text Available Grey heron Ardea cinerea Ardea_cinerea_L.png 192.png Takeru Nakazato (Database Center for Life Science...zato (Database Center for Life Science) nakazato 2009/11/04 17:28:11 2010/01/14 20:04:35 ...

  16. RHENIUM SOLUBILITY IN BOROSILICATE NUCLEAR WASTE GLASS IMPLICATIONS FOR THE PROCESSING AND IMMOBILIZATION OF TECHNETIUM-99 (AND SUPPORTING INFORMATION WITH GRAPHICAL ABSTRACT)

    Energy Technology Data Exchange (ETDEWEB)

    AA KRUGER; A GOEL; CP RODRIGUEZ; JS MCCLOY; MJ SCHWEIGER; WW LUKENS; JR, BJ RILEY; D KIM; M LIEZERS; P HRMA

    2012-08-13

    The immobilization of 99Tc in a suitable host matrix has proved a challenging task for researchers in the nuclear waste community around the world. At the Hanford site in Washington State in the U.S., the total amount of 99Tc in low-activity waste (LAW) is {approx} 1,300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility and retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW sodium borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant because of previously established similarities in ionic radii and other chemical aspects. The glasses containing target Re concentrations varying from 0 to10,000 ppm by mass were synthesized in vacuum-sealed quartz ampoules to minimize the loss of Re by volatilization during melting at 1000 DC. The rhenium was found to be present predominantly as Re7 + in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be {approx}3,000 ppm (by mass) using inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of alkali perrhenate crystalline inclusions detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). Assuming justifiably substantial similarities between Re7 + and Tc 7+ behavior in this glass system, these results implied that the processing and immobilization of 99Tc from radioactive wastes should not be limited by the solubility of 99Tc in borosilicate LAW glasses.

  17. 41 CFR 102-192.170 - What are GSA's responsibilities in mail management?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What are GSA's responsibilities in mail management? 102-192.170 Section 102-192.170 Public Contracts and Property Management... PROGRAMS 192-MAIL MANAGEMENT GSA's Responsibilities and Services § 102-192.170 What are GSA's...

  18. 22 CFR 192.1 - Declarations of hostile action.

    Science.gov (United States)

    2010-04-01

    ... 192.1 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION General § 192.1 Declarations of hostile action. (a)(1) The Secretary of State shall declare when and where individuals in the Civil Service of the United States, including members of the Foreign Service and foreign...

  19. 49 CFR 192.475 - Internal corrosion control: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: General. 192.475... Control § 192.475 Internal corrosion control: General. (a) Corrosive gas may not be transported by... taken to minimize internal corrosion. (b) Whenever any pipe is removed from a pipeline for any reason...

  20. Rhenium Alloys as Ductile Substrates for Diamond Thin-Film Electrodes.

    Science.gov (United States)

    Halpern, Jeffrey M; Martin, Heidi B

    2014-02-01

    Molybdenum-rhenium (Mo/Re) and tungsten-rhenium (W/Re) alloys were investigated as substrates for thin-film, polycrystalline boron-doped diamond electrodes. Traditional, carbide-forming metal substrates adhere strongly to diamond but lose their ductility during exposure to the high-temperature (1000°C) diamond, chemical vapor deposition environment. Boron-doped semi-metallic diamond was selectively deposited for up to 20 hours on one end of Mo/Re (47.5/52.5 wt.%) and W/Re (75/25 wt.%) alloy wires. Conformal diamond films on the alloys displayed grain sizes and Raman signatures similar to films grown on tungsten; in all cases, the morphology and Raman spectra were consistent with well-faceted, microcrystalline diamond with minimal sp 2 carbon content. Cyclic voltammograms of dopamine in phosphate-buffered saline (PBS) showed the wide window and low baseline current of high-quality diamond electrodes. In addition, the films showed consistently well-defined, dopamine electrochemical redox activity. The Mo/Re substrate regions that were uncoated but still exposed to the diamond-growth environment remained substantially more flexible than tungsten in a bend-to-fracture rotation test, bending to the test maximum of 90° and not fracturing. The W/Re substrates fractured after a 27° bend, and the tungsten fractured after a 21° bend. Brittle, transgranular cleavage fracture surfaces were observed for tungsten and W/Re. A tension-induced fracture of the Mo/Re after the prior bend test showed a dimple fracture with a visible ductile core. Overall, the Mo/Re and W/Re alloys were suitable substrates for diamond growth. The Mo/Re alloy remained significantly more ductile than traditional tungsten substrates after diamond growth, and thus may be an attractive metal substrate for more ductile, thin-film diamond electrodes.

  1. 41 CFR 102-192.120 - Must we have an agency mail manager?

    Science.gov (United States)

    2010-07-01

    ... mail manager? 102-192.120 Section 102-192.120 Public Contracts and Property Management Federal Property... MANAGEMENT Agency Mail Manager Requirements § 102-192.120 Must we have an agency mail manager? Yes, every Federal agency as defined in § 102-192.35 must have an agency mail manager. Agencies that are not “large...

  2. 49 CFR 192.627 - Tapping pipelines under pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Tapping pipelines under pressure. 192.627 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Operations § 192.627 Tapping pipelines under pressure. Each tap made on a pipeline under pressure must be performed by a crew qualified to make...

  3. Epitaxial growth of rhenium with sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Seongshik [National Institute of Standards and Technology, Boulder, CO 80305 (United States) and Department of Physics, University of Illinois, Urbana, IL 61801 (United States)]. E-mail: soh@boulder.nist.gov; Hite, Dustin A. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Cicak, K. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Osborn, Kevin D. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Simmonds, Raymond W. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); McDermott, Robert [University of California, Santa Barbara, CA 93106 (United States); Cooper, Ken B. [University of California, Santa Barbara, CA 93106 (United States); Steffen, Matthias [University of California, Santa Barbara, CA 93106 (United States); Martinis, John M. [University of California, Santa Barbara, CA 93106 (United States); Pappas, David P. [National Institute of Standards and Technology, Boulder, CO 80305 (United States)

    2006-02-21

    We have grown epitaxial Rhenium (Re) (0001) films on {alpha}-Al{sub 2}O{sub 3} (0001) substrates using sputter deposition in an ultra high vacuum system. We find that better epitaxy is achieved with DC rather than with RF sputtering. With DC sputtering, epitaxy is obtained with the substrate temperatures above 700 deg. C and deposition rates below 0.1 nm/s. The epitaxial Re films are typically composed of terraced hexagonal islands with screw dislocations, and island size gets larger with high temperature post-deposition annealing. The growth starts in a three dimensional mode but transforms into two dimensional mode as the film gets thicker. With a thin ({approx}2 nm) seed layer deposited at room temperature and annealed at a high temperature, the initial three dimensional growth can be suppressed. This results in larger islands when a thick film is grown at 850 deg. C on the seed layer. We also find that when a room temperature deposited Re film is annealed to higher temperatures, epitaxial features start to show up above {approx}600 deg. C, but the film tends to be disordered.

  4. Alkene-glycol interconversion with technetium and rhenium oxo complexes

    International Nuclear Information System (INIS)

    Pearlstein, R.M.; Davison, Alan

    1988-01-01

    The trioxotechnetium(VII) complexes TcO 3 Cl(AA) (AA = phen, bpy, 5-NO 2 -phen, 3,4,7,8-Me 4 -phen) cleanly oxidize olefins (C 2 R 4 ) in solution at 22 0 C, forming in high yields the corresponding oxotechnetium(V) diolate complexes, TcOCl(OCR 2 CR 2 O)(AA). The complexes have been characterized by 1 H NMR, IR, elemental analysis, and fast atom bombardment mass spectrometry. The free diols isolated by hydrolysis of these diolate complexes with HCl were shown by capillary gas chromatography to represent syn addition of the two hydroxyl groups across the double bond. The related rhenium complex, ReOCl(OCH 2 CH 2 O)(phen) undergoes the reverse reaction when thermalized, releasing ethylene and producing ReO 3 Cl(phen). (author)

  5. Analysis of a rhenium-osmium solid-solution spike by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Richardson, J.M.; Dickin, A.P.; McNutt, R.H.; McAndrew, J.I.; Beneteau, S.B.

    1989-01-01

    The rhenium-osmium decay scheme ( 187 Re → 187 Os) offers a unique opportunity to investigate the genesis of, and directly date, ultramafic rock, sulphide and platinum ore deposits. Inductively coupled plasma mass spectrometry (ICP-MS) is a viable method for Os isotopic analysis as it provides the high temperatures necessary to ionise Os. The sample can be introduced into the ICP mass spectrometer either by conventional nebulisation or by distillation using an Os ''generator''. Generator-mode analysis is superior to nebulisation because (i) the total number of counts is two orders of magnitude higher for a given sample size and (ii) Os oxidises readily to volatile OsO 4 , which has a boiling-point lower than most Re compounds, so that Os can be efficiently separated from 187 Re. The importance of Os loss during sample preparation was minimised by combining the sample powder with a powdered Re-Os isotopic spike prior to any chemical treatment. The spike is in a nickel sulphide matrix and was made by a thioacetamide co-precipitation of Os, Re and Ni followed by a fire assay. The 190 Os/ 192 Os ratio in this preparation is 51.5 ± 0.9, the 187 Os 188 Os ratio is 0.063 ± 0.006 and the 185 Re/ 187 Re ratio is 17.04 - + 0.41. These values are within the error limits quoted by the Oak Ridge National Laboratory and Techsnabexport, the suppliers of the metallic spikes. Parameters that significantly influence the Os analyses include the oxidising agent and the run temperature. The oxidising agent H 5 IO 6 is preferred to H 2 O 2 or HNO 3 as it has the highest electrode potential, provides a prolonged, consistent reaction and is more stable when stored. Chilling the sample and the H 5 IO 6 , initially retards uncontrolled OsO 4 emission. Heat applied later in the run releases OsO 4 and helps maintain a high count rate. Thus, OsO 4 can be generated in a steady, controllable and reproducible manner. (author)

  6. Broad Detection Range Rhenium Diselenide Photodetector Enhanced by (3-Aminopropyl)Triethoxysilane and Triphenylphosphine Treatment.

    Science.gov (United States)

    Jo, Seo-Hyeon; Park, Hyung-Youl; Kang, Dong-Ho; Shim, Jaewoo; Jeon, Jaeho; Choi, Seunghyuk; Kim, Minwoo; Park, Yongkook; Lee, Jaehyeong; Song, Young Jae; Lee, Sungjoo; Park, Jin-Hong

    2016-08-01

    The effects of triphenylphosphine and (3-aminopropyl)triethoxysilane on a rhenium diselenide (ReSe2 ) photodetector are systematically studied by comparing with conventional MoS2 devices. This study demonstrates a very high performance ReSe2 photodetector with high photoresponsivity (1.18 × 10(6) A W(-1) ), fast photoswitching speed (rising/decaying time: 58/263 ms), and broad photodetection range (possible above 1064 nm). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Cep192 controls the balance of centrosome and non-centrosomal microtubules during interphase.

    Directory of Open Access Journals (Sweden)

    Brian P O'Rourke

    Full Text Available Cep192 is a centrosomal protein that contributes to the formation and function of the mitotic spindle in mammalian cells. Cep192's mitotic activities stem largely from its role in the recruitment to the centrosome of numerous additional proteins such as gamma-tubulin and Pericentrin. Here, we examine Cep192's function in interphase cells. Our data indicate that, as in mitosis, Cep192 stimulates the nucleation of centrosomal microtubules thereby regulating the morphology of interphase microtubule arrays. Interestingly, however, cells lacking Cep192 remain capable of generating normal levels of MTs as the loss of centrosomal microtubules is augmented by MT nucleation from other sites, most notably the Golgi apparatus. The depletion of Cep192 results in a significant decrease in the level of centrosome-associated gamma-tubulin, likely explaining its impact on centrosome microtubule nucleation. However, in stark contrast to mitosis, Cep192 appears to maintain an antagonistic relationship with Pericentrin at interphase centrosomes. Interphase cells depleted of Cep192 display significantly higher levels of centrosome-associated Pericentrin while overexpression of Cep192 reduces the levels of centrosomal Pericentrin. Conversely, depletion of Pericentrin results in elevated levels of centrosomal Cep192 and enhances microtubule nucleation at centrosomes, at least during interphase. Finally, we show that depletion of Cep192 negatively impacts cell motility and alters normal cell polarization. Our current working hypothesis is that the microtubule nucleating capacity of the interphase centrosome is determined by an antagonistic balance of Cep192, which promotes nucleation, and Pericentrin, which inhibits nucleation. This in turn determines the relative abundance of centrosomal and non-centrosomal microtubules that tune cell movement and shape.

  8. 41 CFR 102-192.25 - Does this part apply to me?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT Introduction to this Part § 102-192.25 Does this part apply to me? Yes, this part applies to you... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Does this part apply to me? 102-192.25 Section 102-192.25 Public Contracts and Property Management Federal Property...

  9. 49 CFR 192.357 - Customer meters and regulators: Installation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  10. 49 CFR 192.513 - Test requirements for plastic pipelines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Test requirements for plastic pipelines. 192.513 Section 192.513 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Test requirements for plastic pipelines. (a) Each segment of a plastic pipeline must be tested in...

  11. Development of pharmaceuticals with radioactive rhenium for cancer therapy. Production of {sup 186}Re and {sup 188}Re, synthesis of labeled compounds and their biodistributions

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Production of the radioactive rhenium isotopes {sup 186}Re and {sup 188}Re, and synthesis of their labeled compounds have been studied together with the biodistributions of the compounds. This work was carried out by the Working Group on Radioactive Rhenium, consisting of researchers of JAERI and some universities, in the Subcommittee for Production and Radiolabeling under the Consultative Committee of Research on Radioisotopes. For {sup 186}Re, production methods by the {sup 185}Re(n,{gamma}){sup 186}Re reaction in a reactor and by the {sup 186}W(p,n){sup 186}Re reaction with an accelerator, which can produce nocarrier-added {sup 186}Re, have been established. For {sup 188}Re, a production method by the double neutron capture reaction of {sup 186}W, which produces a {sup 188}W/{sup 188}Re generator, has been established. For labeling of bisphosphonate, DMSA, DTPA, DADS, aminomethylenephosphonate and some monoclonal antibodies with the radioactive rhenium isotopes, the optimum conditions, including pH, the amounts of reagents and so on, have been determined for each compound. The biodistributions of each of the labeled compounds in mice have been also obtained. (author)

  12. 49 CFR 192.57 - [Reserved

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.57 [Reserved] ...

  13. 49 CFR 192.61 - [Reserved

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.61 [Reserved] ...

  14. 22 CFR 192.2 - Application for determination of eligibility.

    Science.gov (United States)

    2010-04-01

    .... 192.2 Section 192.2 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM... addressed to the Director General of the Foreign Service, Department of State, Washington, DC 20520... State there is good cause for the late filing. Applications in connection with hostile action in...

  15. Synthesis, molecular structure and magnetic properties of a rhenium(IV) compound with catechol

    Science.gov (United States)

    Cuevas, A.; Geis, L.; Pintos, V.; Chiozzone, R.; Sanchíz, J.; Hummert, M.; Schumann, H.; Kremer, C.

    2009-03-01

    A novel Re(IV) complex containing catechol as ligand has been prepared and characterized. The crystal structure of (HNEt 3)(NBu 4)[ReCl 4(cat)]·H 2cat was determined. The rhenium ion presents a distorted octahedral geometry, being bonded to a bidentate catecholate group and four chloride anions. The magnetic properties of the complex were studied, a /2 D/ (the energy gap between ±3/2 and ±1/2 Kramers doublets) value of 190(10) cm -1. This is the largest /2 D/ value reported for Re(IV) up to now.

  16. Design criteria for rhenium-reduced nickel-based single-crystal alloys. Identification and computer-assisted conversion

    International Nuclear Information System (INIS)

    Goehler, Thomas

    2016-01-01

    In the present work, design criteria and property models for the creep strength optimization of rhenium-free nickel based single crystal Superalloys are investigated. The study focuses on a typical load condition of 1050 C and 150 MPa, which is representative for flight engine applications. Thereby the key aspect is to link chemical composition, manufacturing processes, microstructure formation and mechanistic understanding of dislocation creep through a computational materials engineering approach. Beside the positive effect of rhenium on solid solution hardening, a second mechanism in which rhenium increases high temperature creep strength is identified. It indirectly stabilizes precipitation hardening by reducing the coarsening kinetics of γ'-rafting. Five 1st and 2nd generation technical Superalloys show a comparable microstructure evolution for up to 2 % plastic elongation, while creep times differ by a factor of five. The application of a microstructure sensitive creep model shows that these coarsening processes can activate γ-cutting and thus lead to an increasing creep rate. Based on these calculations a threshold value of φ γ/γ' > 2,5 at 150 MPa is estimated. This ratio of matrix channel to raft thickness has been proofed for multiple positions by microstructure analysis of interrupted creep tests. The mechanism described previously can be decelerated by the enrichment of the γ-matrix with slow diffusing elements. The same principle also increases the solid solution strength of the γ-matrix. Therefore, the present work delivers an additional mechanistic explanation why creep properties of single phase nickel based alloys can be transferred to two phase technical Superalloys with rafted γ'-structure. Following, the best way to substitute both rhenium fundamental properties, namely a slow diffusion coefficient and a small solubility in g', has been investigated by means of CALPHAD-modeling. Only molybdenum and especially tungsten

  17. The Influence of Cobalt and Rhenium on the Behaviour of MCrAlY Coatings

    OpenAIRE

    Täck, Ulrike

    2009-01-01

    Superalloys are widely applied as materials for components in the hot section of gas turbines. As superalloys have a limited oxidation life, the application of a coating is vital. The most commonly applied coatings in stationary gas turbines are MCrAlY coatings. Since the turbine components are exposed to high cyclic thermal stresses, MCrAlY coatings must also show a high thermal fatigue resistance. In this thesis, the effect of Cobalt and Rhenium on microstructure, oxidation and thermal fati...

  18. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Plastic pipe: Qualifying joining procedures. 192... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  19. 49 CFR 192.193 - Valve installation in plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve installation in plastic pipe. 192.193... Components § 192.193 Valve installation in plastic pipe. Each valve installed in plastic pipe must be designed so as to protect the plastic material against excessive torsional or shearing loads when the valve...

  20. 49 CFR 192.619 - Maximum allowable operating pressure: Steel or plastic pipelines.

    Science.gov (United States)

    2010-10-01

    ... plastic pipelines. 192.619 Section 192.619 Transportation Other Regulations Relating to Transportation... Operations § 192.619 Maximum allowable operating pressure: Steel or plastic pipelines. (a) No person may operate a segment of steel or plastic pipeline at a pressure that exceeds a maximum allowable operating...

  1. Quasiparticle excitations in superdeformed {sup 192}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Lauritsen, T.; Carpenter, M.P.; Janssens, R.V.F. [and others

    1995-08-01

    The nucleus {sup 192}Hg plays a pivotal role for superdeformation in the mass 190 region, since calculations of single-particle levels show large shell-gaps for the superdeformed (SD) shape at N = 112 and Z = 80. As a result, {sup 192}Hg is referred to as the doubly magic SD nucleus for the A = 190 region. In previous studies, only one superdeformed band was observed in this nucleus, and this fact was cited as indirect evidence that large shell gaps do indeed exist at the proposed particle numbers.

  2. 49 CFR 192.53 - General.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.53 General. Materials for pipe and...

  3. 49 CFR 192.271 - Scope.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Joining of Materials Other Than by Welding § 192.271...

  4. 49 CFR 192.273 - General.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Joining of Materials Other Than by Welding § 192.273...

  5. Advantages of using 192Ir γ-ray flaw detector for some products

    International Nuclear Information System (INIS)

    Qin Xiqi

    1989-01-01

    This paper describes the advantages of 192 Ir γ-ray flaw detector made in China in welding seam testings. The authors made a comparison between 192 Ir γ-ray and X-ray machine. 192 Ir γ-ray machine showed many advantages, such as shorter working hours and less labour intensity

  6. Fate of rhenium in the environment as a chemical analogue of technetium

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2007-01-01

    Concentrations of rhenium, a chemical analogue of Tc, were measured in various environmental samples by ICP-MS to obtain information values on long-lived 99 Tc mobility in the environment. From the results, it was assumed that Re was removed from the rock and soil by water due to weathering and transport to the sea through rivers. The element would be retained in seawater for a long time, i.e., 2 x 10 5 to 7.5 x 10 5 y. The reservoirs of Re in the sea would be seaweeds, and anoxic and suboxic sediments, especially slightly below the water-sediment interface. (author)

  7. Hot rocket plume experiment - Survey and conceptual design. [of rhenium-iridium bipropellants

    Science.gov (United States)

    Millard, Jerry M.; Luan, Taylor W.; Dowdy, Mack W.

    1992-01-01

    Attention is given to a space-borne engine plume experiment study to fly an experiment which will both verify and quantify the reduced contamination from advanced rhenium-iridium earth-storable bipropellant rockets (hot rockets) and provide a correlation between high-fidelity, in-space measurements and theoretical plume and surface contamination models. The experiment conceptual design is based on survey results from plume and contamination technologists throughout the U.S. With respect to shuttle use, cursory investigations validate Hitchhiker availability and adaptability, adequate remote manipulator system (RMS) articulation and dynamic capability, acceptable RMS attachment capability, adequate power and telemetry capability, and adequate flight altitude and attitude/orbital capability.

  8. Issues associated with the use of the Tungsten-188/Rhenium188 generator and concentrator system and preparation of Re-188 HDD: A report

    International Nuclear Information System (INIS)

    Knapp, F.F.Jr.; Turner, J.H.; Jeong, J.-M.; Padhy, A.K.

    2004-01-01

    The ready availability of no-carrier-added Rhenium-188 from the Tungsten-188/Rhenium-188 generator represents an important source of a therapeutic radioisotope for a broad range of therapeutic applications in nuclear medicine, oncology, rheumatology and interventional cardiology. The International Atomic Energy Agency (IAEA) is coordinating a clinical trial involving the use of Rhenium188-Lipiodol for therapy of hepatocellular carcinoma. This report summarizes the experience of investigators at ten participating centres associated with the use and performance of the Tungsten-188/Rhenium-188 generators and the preparation and handling of the Re-188 HDD agent. This evaluation has demonstrated the cost effective provision of on-site therapeutic activities of Rhenium-188 and recommendations are made for further development of the next generator prototype in light of this international experience. The high bolus volumes (20-40 ml) of the ORNL generator requires post elution concentration of the Re-188 bolus by passage through the tandem silver cation/anion column system. The high back pressure often encountered during generator elution through the silver cation/anion concentrator system has been identified as a potential problem. The details of a method involving in house preparation of the silver cation columns were provided and implementation of this method for Re-188 bolus concentration is recommended. It is also recommended that ORNL investigators reassess the possibility of increasing Tungsten generator loading capacity and the use of higher specific activity Tungsten-188, with a view to reducing the generator bolus volume. The Re-188 HDD/Lipiodol conjugate?;ate is used in this IAEA trial for radioembolytic therapy of primary liver cancer, and methods for preparation of Re-188 HDD and its extraction into Lipiodol are discussed. Since Re-188 HDD binds to glass surfaces, the recovery yields are variable and can be as low as 40-45%. In an effort to maximize the

  9. Elementary steps of the catalytic oxidation of CO in a gas phase in the presence of rhenium cations with carbonyl and oxygen ligands: a comparison with heterogeneous catalysis

    International Nuclear Information System (INIS)

    Goncharov, V.B.; Fialko, E.F.; Shejnin, D.Eh.; Kikhtenko, A.V.

    1997-01-01

    Reactivity in a gaseous phase o rhenium (Re + ) and rhenium monocarbonyl (ReCO + ) in the reaction of CO oxidation in oxygen-containing reagents (NO, O 2 , H 2 O) is studied through the method of the ionic cyclotron resonance. It is shown that presence of carbonyl ligand essentially influences the ion reactivity. The effective channel of the metal monocarbonyl ions oxidation through molecular oxygen is found. Accounting for this stage makes of possible to explain the low-temperature activity of a number of oxide catalyzer Mo, W in the reaction of CO oxidation by molecular oxygen

  10. 49 CFR 19.2 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS General § 19.2... acquired. Other charges, such as the cost of installation, transportation, taxes, duty or protective in... higher education, public and private hospitals, and other quasi-public and private non-profit...

  11. Mass spectrometry of rhenium complexes: a comparative study by using LDI-MS, MALDI-MS, PESI-MS and ESI-MS.

    Science.gov (United States)

    Petroselli, Gabriela; Mandal, Mridul Kanti; Chen, Lee Chuin; Ruiz, Gustavo T; Wolcan, Ezequiel; Hiraoka, Kenzo; Nonami, Hiroshi; Erra-Balsells, Rosa

    2012-03-01

    A group of rhenium (I) complexes including in their structure ligands such as CF(3)SO(3)-, CH(3)CO(2)-, CO, 2,2'-bipyridine, dipyridil[3,2-a:2'3'-c]phenazine, naphthalene-2-carboxylate, anthracene-9-carboxylate, pyrene-1-carboxylate and 1,10-phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF-ESI-CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M](+·) and to produce their reduction yielding the gas species [M](-·). It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV-visible region, particularly at 355 nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix-assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor-harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M](-·) species. Results obtained with 2-[(2E)-3-(4-tert-buthylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones. Copyright © 2012 John Wiley & Sons, Ltd.

  12. SSR Analysis of Genetic Diversity Among 192 Diploid Potato Cultivars

    Directory of Open Access Journals (Sweden)

    Xiaoyan Song

    2016-05-01

    Full Text Available In potato breeding, it is difficult to improve the traits of interest at the tetraploid level due to the tetrasomic inheritance. A promising alternative is diploid breeding. Thus it is necessary to assess the genetic diversity of diploid potato germplasm for efficient exploration and deployment of desirable traits. In this study, we used SSR markers to evaluate the genetic diversity of diploid potato cultivars. To screen polymorphic SSR markers, 55 pairs of SSR primers were employed to amplify 39 cultivars with relatively distant genetic relationships. Among them, 12 SSR markers with high polymorphism located at 12 chromosomes were chosen to evaluate the genetic diversity of 192 diploid potato cultivars. The primers produced 6 to 18 bands with an average of 8.2 bands per primer. In total, 98 bands were amplified from 192 cultivars, and 97 of them were polymorphic. Cluster analysis using UPGMA showed the genetic relationships of all accessions tested: 186 of the 192 accessions could be distinguished by only 12 pairs of SSR primers, and the 192 diploid cultivars were divided into 11 groups, and 83.3% constituted the first group. Clustering results showed relatively low genetic diversity among 192 diploid cultivars, with closer relationship at the molecular level. The results can provide molecular basis for diploid potato breeding.

  13. 41 CFR 102-192.30 - What types of mail does this part apply to?

    Science.gov (United States)

    2010-07-01

    ... 192-MAIL MANAGEMENT Introduction to this Part § 102-192.30 What types of mail does this part apply to... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What types of mail does this part apply to? 102-192.30 Section 102-192.30 Public Contracts and Property Management Federal...

  14. Rhenium(5) and molybdenum(5) complexes with 4',4(5)-divaleryldibenzo-18-crown-6

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.; Tashmukhamedova, A.K.; Basitova, S.M.

    1993-01-01

    Methods for synthesizing oxohalide complexes of rhenium and molybdenum with +5 oxidation degree with 4',4 (5) -divaleryldibenzo-18-crown-6 were developed. Content and composition of prepared compounds were investigated by the methods of element analysis, crystal optics, conductometry, IR spectroscopy in the near and far regions, thermogravimetry. Oxidation degree of the complex-forming metal was determined. It was established that composition of the compounds coressponded to the general formula MOLX · H 2 O, where M - Re, Mo; L -4',4 (5) -divaleryldibenzo-18-crown-6; X -Cl - , Br -

  15. Mechanical properties of tungsten following rhenium ion and helium plasma exposure

    Directory of Open Access Journals (Sweden)

    C.S. Corr

    2017-08-01

    Full Text Available Mechanical properties of Tungsten (W samples irradiated with 2 MeV Rhenium (Re ions and helium (He plasma were investigated using nanoindentation. It was found that there was an increase in hardness for all samples following separate irradiation with both Re ion and He plasma. A slight increase in hardness was obtained for combined exposures. A comparable increase in hardness was observed for a pure He plasma with a sample temperature of 473 K and 1273 K. Optical interferometry was employed to compare surface modification of the samples. Grazing incidence small angle x-ray scattering confirmed He nano-bubble formation of approximately 1 nm diameter in the higher temperature sample, which was not observed with samples at the lower temperatures.

  16. 22 CFR 192.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION General § 192.3 Definitions. When used in this subchapter, unless otherwise specified, the terms— (a) Secretary of State includes any person to whom the Secretary of State has delegated the responsibilities of carrying out this...

  17. Rhenium Dichalcogenides: Layered Semiconductors with Two Vertical Orientations.

    Science.gov (United States)

    Hart, Lewis; Dale, Sara; Hoye, Sarah; Webb, James L; Wolverson, Daniel

    2016-02-10

    The rhenium and technetium diselenides and disulfides are van der Waals layered semiconductors in some respects similar to more well-known transition metal dichalcogenides (TMD) such as molybdenum sulfide. However, their symmetry is lower, consisting only of an inversion center, so that turning a layer upside-down (that is, applying a C2 rotation about an in-plane axis) is not a symmetry operation, but reverses the sign of the angle between the two nonequivalent in-plane crystallographic axes. A given layer thus can be placed on a substrate in two symmetrically nonequivalent (but energetically similar) ways. This has consequences for the exploitation of the anisotropic properties of these materials in TMD heterostructures and is expected to lead to a new source of domain structure in large-area layer growth. We produced few-layer ReS2 and ReSe2 samples with controlled "up" or "down" orientations by micromechanical cleavage and we show how polarized Raman microscopy can be used to distinguish these two orientations, thus establishing Raman as an essential tool for the characterization of large-area layers.

  18. High dose rate 192Ir calibration: Indonesia experiences

    International Nuclear Information System (INIS)

    Nasukha; Tjiptanto, D.; Darmasyah, R.; Kurniawan, B.

    2002-01-01

    Indonesia with a population of more than 200 Million people which spread on about 5000 islands, up to now only has 23 radiotherapy centers and some not active anymore. As mention by Parkin et al that Cervix/Utery and breast cancer are the most estimated numbers of new cases of cancers in women for developing countries, stomach and lung cancers in men. Indonesia as a developing country is likely similar to other developing countries on numbers of new cases of cancers in women. But quite different in men, in Indonesia the most common cancers are nasopharynx and thyroid cancers. The use of lr-192 sources in high dose-rate (HDR) remotely afterloaded brachytherapy treatments have greatly increased in recent years and variety of such sources are commercially available. Nine radiotherapy centers in Indonesia installed Nucletron microSelectron HDR remote afterloader. Based on the data of CiptoMangunkusurno Hospital, Jakarta that the most common cancers are the cervix, breast, nasopharynx and thyroid cancers which of percentage are about 31%, 25 %, 13%, and 6 % respectively. It means that the use of HDR 192 Ir brachytherapy has to be an effective tool in the treatments. Two methods have been studied and applied to calibrate HDR 192 Ir brachytherapy in Indonesia, especially for Nucletron microSelectron HDR 192 lr remote afterloader brachytherapy. Calibration of HDR 192 Ir brachytherapy source has been done by Cavity lonization Chamber and with Well Type lonization Chamber. First, 0.6 cc of NE Farmer type dosimeter that was calibrated to 60 Co and 250 kV of x-rays in air kerma was used in this experiment. Position of measurement (detector and source) at the center of the room and about 1 meter from the floor. Eight variation of distances from 10 cm to 40 cms have been carried out measurement as recommended by IAEA-TECDOC-1079. Correction have been given for scatters, non-uniformity, and attenuation. To solve the problem of scatter correction factor was used Matlab programming

  19. Superhard Rhenium/Tungsten Diboride Solid Solutions.

    Science.gov (United States)

    Lech, Andrew T; Turner, Christopher L; Lei, Jialin; Mohammadi, Reza; Tolbert, Sarah H; Kaner, Richard B

    2016-11-02

    Rhenium diboride (ReB 2 ), containing corrugated layers of covalently bonded boron, is a superhard metallic compound with a microhardness reaching as high as 40.5 GPa (under an applied load of 0.49 N). Tungsten diboride (WB 2 ), which takes a structural hybrid between that of ReB 2 and AlB 2 , where half of the boron layers are planar (as in AlB 2 ) and half are corrugated (as in ReB 2 ), has been shown not to be superhard. Here, we demonstrate that the ReB 2 -type structure can be maintained for solid solutions of tungsten in ReB 2 with tungsten content up to a surprisingly large limit of nearly 50 atom %. The lattice parameters for the solid solutions linearly increase along both the a- and c-axes with increasing tungsten content, as evaluated by powder X-ray and neutron diffraction. From micro- and nanoindentation hardness testing, all of the compositions within the range of 0-48 atom % W are superhard, and the bulk modulus of the 48 atom % solid solution is nearly identical to that of pure ReB 2 . These results further indicate that ReB 2 -structured compounds are superhard, as has been predicted from first-principles calculations, and may warrant further studies into additional solid solutions or ternary compounds taking this structure type.

  20. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Byrne, A. R.; Mizera, Jiří; Lučaníková, M.; Řanda, Zdeněk

    2006-01-01

    Roč. 269, č. 2 (2006), s. 251-257 ISSN 0236-5731 R&D Projects: GA ČR(CZ) GA203/04/0943 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiochemical neutron activation analysis * rhenium * biological and environmental samples Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.509, year: 2006

  1. 41 CFR 102-192.155 - What should our agency-wide mail management policy statement cover?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What should our agency-wide mail management policy statement cover? 102-192.155 Section 102-192.155 Public Contracts and... REGULATION ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Other Agency Responsibilities § 102-192.155 What...

  2. Photocatalytic Conversion of CO2 to CO using Rhenium Bipyridine Platforms Containing Ancillary Phenyl or BODIPY Moieties

    Science.gov (United States)

    Andrade, Gabriel A.; Pistner, Allen J.; Yap, Glenn P.A.; Lutterman, Daniel A.; Rosenthal, Joel

    2013-01-01

    Harnessing of solar energy to drive the reduction of carbon dioxide to fuels requires the development of efficient catalysts that absorb sunlight. In this work, we detail the synthesis, electrochemistry and photophysical properties of a set of homologous fac-ReI(CO)3 complexes containing either an ancillary phenyl (8) or BODIPY (12) substituent. These studies demonstrate that both the electronic properties of the rhenium center and BODIPY chromophore are maintained for these complexes. Photolysis studies demonstrate that both assemblies 8 and 12 are competent catalysts for the photochemical reduction of CO2 to CO in DMF using triethanolamine (TEOA) as a sacrificial reductant. Both compounds 8 and 12 display TOFs for photocatalytic CO production upon irradiation with light (λex ≥ 400 nm) of ~5 hr−1 with TON values of approximately 20. Although structural and photophysical measurements demonstrate that electronic coupling between the BODIPY and fac-ReI(CO)3 units is limited for complex 12, this work clearly shows that the photoactive BODIPY moiety is tolerated during catalysis and does not interfere with the observed photochemistry. When taken together, these results provide a clear roadmap for the development of advanced rhenium bipyridine complexes bearing ancillary BODIPY groups for the efficient photocatalytic reduction of CO2 using visible light. PMID:24015374

  3. 41 CFR 102-192.130 - What are your general responsibilities as an agency mail manager?

    Science.gov (United States)

    2010-07-01

    ... responsibilities as an agency mail manager? 102-192.130 Section 102-192.130 Public Contracts and Property... ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Agency Mail Manager Requirements § 102-192.130 What are your general responsibilities as an agency mail manager? In addition to carrying out the responsibilities in Subparts B, C, D...

  4. 41 CFR 102-192.135 - Must we have a mail center manager at our facility?

    Science.gov (United States)

    2010-07-01

    ... center manager at our facility? 102-192.135 Section 102-192.135 Public Contracts and Property Management... PROGRAMS 192-MAIL MANAGEMENT Mail Center Manager Requirements § 102-192.135 Must we have a mail center manager at our facility? Yes, every facility that has more than two full time people dedicated to...

  5. Rhenium and technetium complexes with phenylbis(2-pyridyl)phosphine and tris(2-pyridyl)phosphine

    Energy Technology Data Exchange (ETDEWEB)

    Saucedo A, S. A. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Hagenbach, A.; Abram, U., E-mail: ssaucedo@uaz.edu.m [Institut fur Chemie und Biochemie, Freie Universitat Berlin, Fabeckstr. 34-36, D-14195, Berlin (Germany)

    2010-10-15

    Reactions of common technetium and rhenium precursors with 2-pyridyl phosphines produce novel, air stable tricarbonyl and oxo complexes. (NEt{sub 4}){sub 2}[Re(CO){sub 3}Br{sub 3}] or (NEt{sub 4}){sub 2}[Tc(CO){sub 3}Cl{sub 3}] react with phenylbis(2-pyridyl)phosphine (PPhpy{sub 2}) or tris(2-pyridyl)phosphine (Ppy{sub 3}) under formation of neutral tricarbonyl complexes of the composition [M(CO){sub 3}X(L)] (M = Re, X = Br; M = Tc, X = Cl, L = PPhpy{sub 2} or Ppy{sub 3}), where the ligands coordinate only with two for their nitrogen atoms. Removal of the bromo ligands from (NEt{sub 4}){sub 2}[Re(CO){sub 3}(Br){sub 3}] with AgNO{sub 3}, to force a tripodal coordination, and the subsequent reaction with the Ppy{sub 3} results in the formation of the complex [Re(CO){sub 3}(NO{sub 3})(Ppy{sub 3}{sup -}N,N{sup '})] with a monodentate coordinated nitrato ligand. (NBu{sub 4})[ReOCl{sub 4}] reacts with PPhpy{sub 2} to give the asymmetric, oxo-bridged rhenium (V) dimer (NBu{sub 4})[Re{sub 2}O{sub 2}Cl{sub 5}({mu}-PPhpy{sub 2}{sup -}P,N,N,N{sup '})({mu}-O)], while a similar reaction with (ReOCl{sub 3}(PPh{sub 3}){sub 2}] in boiling Thf results in reduction of the metal and gives (ReCl{sub 3}(OPPhpy{sub 2})(PPh{sub 3})]. The products have been characterized spectroscopically and by X-ray structure analyses. (Author)

  6. Click-to-Chelate: Development of Technetium and Rhenium-Tricarbonyl Labeled Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Thomas L. Mindt

    2013-03-01

    Full Text Available The Click-to-Chelate approach is a highly efficient strategy for the radiolabeling of molecules of medicinal interest with technetium and rhenium-tricarbonyl cores. Reaction of azide-functionalized molecules with alkyne prochelators by the Cu(I-catalyzed azide-alkyne cycloaddition (CuAAC; click reaction enables the simultaneous synthesis and conjugation of tridentate chelating systems for the stable complexation of the radiometals. In many cases, the functionalization of (biomolecules with the ligand system and radiolabeling can be achieved by convenient one-pot procedures. Since its first report in 2006, Click-to-Chelate has been applied to the development of numerous novel radiotracers with promising potential for translation into the clinic. This review summarizes the use of the Click-to-Chelate approach in radiopharmaceutical sciences and provides a perspective for future applications.

  7. 49 CFR 192.279 - Copper pipe.

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Joining of Materials Other Than by Welding § 192.279...

  8. 49 CFR 192.281 - Plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Joining of Materials Other Than by Welding § 192.281...

  9. 49 CFR 192.59 - Plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.59 Plastic pipe. (a) New plastic pipe...

  10. 49 CFR 192.55 - Steel pipe.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.55 Steel pipe. (a) New steel pipe is...

  11. Catalytic transformation of functionalized carboxylic acids using multifunctional rhenium complexes.

    Science.gov (United States)

    Naruto, Masayuki; Agrawal, Santosh; Toda, Katsuaki; Saito, Susumu

    2017-06-13

    Carboxylic acids (CAs) are one of the most ubiquitous and important chemical feedstocks available from biorenewable resources, CO 2 , and the petrochemical industry. Unfortunately, chemoselective catalytic transformations of CH n CO 2 H (n = 1-3) groups into other functionalities remain a significant challenge. Herein, we report rhenium V complexes as extremely effective precatalysts for this purpose. Compared to previously reported heterogeneous and homogeneous catalysts derived from high- or low-valent metals, the present method involves a α-C-H bond functionalization, a hydrogenation, and a hydrogenolysis, which affords functionalized alcohols with a wide substrate scope and high chemoselectivity under relatively mild reaction conditions. The results represent an important step toward a paradigm shift from 'low-valent' to 'high-valent' metal complexes by exploring a new portfolio of selective functional group transformations of highly oxygenated organic substrates, as well as toward the exploitation of CAs as a valuable biorenewable feedstock.

  12. Solid-state thermolysis of a fac-rhenium(I) carbonyl complex with a redox non-innocent pincer ligand.

    Science.gov (United States)

    Jurca, Titel; Chen, Wen-Ching; Michel, Sheila; Korobkov, Ilia; Ong, Tiow-Gan; Richeson, Darrin S

    2013-03-25

    The development of rhenium(I) chemistry has been restricted by the limited structural and electronic variability of the common pseudo-octahedral products fac-[ReX(CO)3L2] (L2 = α-diimine). We address this constraint by first preparing the bidentate bis(imino)pyridine complexes [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)3X] (X = Cl 2, Br 3), which were characterized by spectroscopic and X-ray crystallographic means, and then converting these species into tridentate pincer ligand compounds, [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)2X] (X = Cl 4, Br 5). This transformation was performed in the solid-state by controlled heating of 2 or 3 above 200 °C in a tube furnace under a flow of nitrogen gas, giving excellent yields (≥95 %). Compounds 4 and 5 define a new coordination environment for rhenium(I) carbonyl chemistry where the metal center is supported by a planar, tridentate pincer-coordinated bis(imino)pyridine ligand. The basic photophysical features of these compounds show significant elaboration in both number and intensity of the d-π* transitions observed in the UV/Vis spec tra relative to the bidentate starting materials, and these spectra were analyzed using time-dependent DFT computations. The redox nature of the bis(imino)pyridine ligand in compounds 2 and 4 was examined by electrochemical analysis, which showed two ligand reduction events and demonstrated that the ligand reduction shifts to a more positive potential when going from bidentate 2 to tridentate 4 (+160 mV for the first reduction step and +90 mV for the second). These observations indicate an increase in electrostatic stabilization of the reduced ligand in the tridentate conformation. Elaboration on this synthetic methodology documented its generality through the preparation of the pseudo-octahedral rhenium(I) triflate complex [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)2OTf] (7, 93 % yield). Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. 41 CFR 102-192.125 - What is the appropriate managerial level for an agency mail manager?

    Science.gov (United States)

    2010-07-01

    ... managerial level for an agency mail manager? 102-192.125 Section 102-192.125 Public Contracts and Property... ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Agency Mail Manager Requirements § 102-192.125 What is the appropriate managerial level for an agency mail manager? The agency mail manager should be at a managerial...

  14. 41 CFR 102-192.140 - What are your general responsibilities as a Federal mail center manager?

    Science.gov (United States)

    2010-07-01

    ... responsibilities as a Federal mail center manager? 102-192.140 Section 102-192.140 Public Contracts and Property... ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Mail Center Manager Requirements § 102-192.140 What are your general responsibilities as a Federal mail center manager? A Federal mail center manager should— (a) Implement policies and...

  15. Experimental determination of the hydrothermal solubility of ReS2 and the Re–ReO2 buffer assemblage and transport of rhenium under supercritical conditions

    Directory of Open Access Journals (Sweden)

    Wood Scott A

    2002-01-01

    Full Text Available To understand the aqueous species important for transport of rhenium under supercritical conditions, we conducted a series of solubility experiments on the Re–ReO2 buffer assemblage and ReS2. In these experiments, pH was buffered by the K–feldspar–muscovite–quartz assemblage; in sulfur-free systems was buffered by the Re–ReO2 assemblage; and and in sulfur-containing systems were buffered by the magnetite–pyrite–pyrrhotite assemblage. Our experimental studies indicate that the species ReCl40 is dominant at 400°C in slightly acidic to near-neutral, and chloride-rich (total chloride concentrations ranging from 0.5 to 1.0 M environments, and ReCl3+ may predominate at 500°C in a solution with total chloride concentrations ranging from 0.5 to 1.5 M. The results also demonstrate that the solubility of ReS2 is about two orders of magnitude less than that of ReO2. This finding not only suggests that ReS2 (or a ReS2 component in molybdenite is the solubility-controlling phase in sulfur-containing, reducing environments but also implies that a mixing process involving an oxidized, rhenium-containing solution and a solution with reduced sulfur is one of the most effective mechanisms for deposition of rhenium. In analogy with Re, TcS2 may be the stable Tc-bearing phase in deep geological repositories of radioactive wastes.

  16. 41 CFR 102-192.40 - Where can we obtain more information about the classes of mail?

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS 192-MAIL MANAGEMENT Introduction to this Part § 102-192.40 Where can we obtain more information... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Where can we obtain more information about the classes of mail? 102-192.40 Section 102-192.40 Public Contracts and Property Management...

  17. Tracing oxidative weathering from the Andes to the lowland Amazon Basin using dissoved rhenium

    Science.gov (United States)

    Dellinger, M.; Hilton, R. G.; West, A. J.; Torres, M.; Burton, K. W.; Clark, K. E.; Baronas, J. J.

    2016-12-01

    Over long timescales (>105 yrs), the abundance of carbon dioxide (CO2) in the atmosphere is determined by the balance of the major carbon sources and sinks. Among the major carbon sources, the oxidation of organic carbon contained within sedimentary rocks ("petrogenic" carbon, or OCpetro) is thought to result in CO2 emission of similar magnitude to that released by volcanism. Rhenium (Re) has been proposed as a proxy for tracing OCpetro oxidation. Here we investigate the source, behavior and flux of dissolved and particulate rhenium (Re) in the Madre de Dios watershed (a major Andean tributary of the Amazon River) and the lowlands, aiming to characterize the behavior of Re in river water and quantify the flux of CO2 released by OCpetro oxidation. Measured Re concentrations in Andean rivers range from 0.07 to 1.55 ppt. In the Andes, Re concentration do not change significantly with water discharge, whereas in the lowlands, Re concentration decrease at high water discharge. Mass balance calculation show that more than 70% of the dissolved Re is sourced from the oxidation of OCpetro the Andes-floodplain system. We calculate dissolved Re flux over a hydrological year to estimate the rates of oxidative weathering, and the associated CO2 release from OCpetro. Rates are high in the Andean headwaters, consistent with estimates from other mountain rivers with similar rates of physical erosion. We find evidence that a significant amount of additional oxidation (Re flux) happens during floodplain transport. These results have important implications for improving our understanding of the source and processes controlling Re in rivers, and allowing us to quantify long-term OCpetro cycling in large river basins.

  18. Effect of rhenium and osmium on mechanical properties of a 9Cr-2W-0.25V-0.07Ta-0.1C steel

    International Nuclear Information System (INIS)

    Klueh, R.L.; Alexander, D.J.; Sokolov, M.A.

    2000-01-01

    The nuclear transmutation of tungsten to rhenium and osmium in a tungsten-containing steel irradiated in a fission or fusion reactor will change the chemical composition of the steel. To determine the possible consequences of such compositional changes on the mechanical properties, tensile and Charpy impact properties were measured on five 9Cr-2W-0.25V-0.07Ta-0.1C steels that contained different amounts of rhenium, osmium, and tungsten. The mechanical properties changes caused by these changes in composition were minor. Observations were also made on the effect of carbon concentration. The effect of carbon on tensile behavior was minor, but there was a large effect on Charpy properties. Several of the steels showed little effect of tempering temperature on the Charpy transition temperature, a behavior that was tentatively attributed to the low silicon and/or manganese concentration of the experimental steels

  19. Absorption behavior of technetium and rhenium through plant roots

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2004-01-01

    The absorption behavior of technetium (Tc) and rhenium (Re) through plant roots was studied using nutrient solution culture. Radish samples, grown in culture solutions for 20-30 days in a green house, were transferred into plastic vessels containing nutrient solutions contaminated with multi-tracer solutions including Tc-95m and Re-183. The plant samples were grown individually for 1-7 days under laboratory conditions. The activities of radionuclides in nutrient solutions and oven-dried plant parts (roots, fleshy roots and leaves) were measured with Ge detecting systems. The concentrations of Tc-95m and Re-183 in the nutrient solutions after harvesting the plants were almost the same as those in the initial solution. Possibly, the radionuclides were taken up with water through plant roots. The distributions of Tc and Re in the plants showed no differences, thus, soluble Tc and Re absorption by plant samples were the same. It is suggested that Re could be used as a geochemical tracer of Tc in the soil environment. (author)

  20. A tungsten-rhenium interatomic potential for point defect studies

    Science.gov (United States)

    Setyawan, Wahyu; Gao, Ning; Kurtz, Richard J.

    2018-05-01

    A tungsten-rhenium (W-Re) classical interatomic potential is developed within the embedded atom method interaction framework. A force-matching method is employed to fit the potential to ab initio forces, energies, and stresses. Simulated annealing is combined with the conjugate gradient technique to search for an optimum potential from over 1000 initial trial sets. The potential is designed for studying point defects in W-Re systems. It gives good predictions of the formation energies of Re defects in W and the binding energies of W self-interstitial clusters with Re. The potential is further evaluated for describing the formation energy of structures in the σ and χ intermetallic phases. The predicted convex-hulls of formation energy are in excellent agreement with ab initio data. In pure Re, the potential can reproduce the formation energies of vacancies and self-interstitial defects sufficiently accurately and gives the correct ground state self-interstitial configuration. Furthermore, by including liquid structures in the fit, the potential yields a Re melting temperature (3130 K) that is close to the experimental value (3459 K).

  1. Radial dose distribution of 192Ir and 137Cs seed sources

    International Nuclear Information System (INIS)

    Thomason, C.; Higgins, P.

    1989-01-01

    The radial dose distributions in water around /sup 192/ Ir seed sources with both platinum and stainless steel encapsulation have been measured using LiF thermoluminescent dosimeters (TLD) for distances of 1 to 12 cm along the perpendicular bisector of the source to determine the effect of source encapsulation. Similar measurements also have been made around a /sup 137/ Cs seed source of comparable dimensions. The data were fit to a third order polynomial to obtain an empirical equation for the radial dose factor which then can be used in dosimetry. The coefficients of this equation for each of the three sources are given. The radial dose factor of the stainless steel encapsulated /sup 192/ Ir and that of the platinum encapsulated /sup 192/ Ir agree to within 2%. The radial dose distributions measured here for /sup 192/ Ir with either type of encapsulation and for /sup 137/ Cs are indistinguishable from those of other authors when considering uncertainties involved. For clinical dosimetry based on isotropic point or line source models, any of these equations may be used without significantly affecting accuracy

  2. 41 CFR 102-192.20 - How are “must” and “should” used in this part?

    Science.gov (United States)

    2010-07-01

    ... 192-MAIL MANAGEMENT Introduction to this Part § 102-192.20 How are “must” and “should” used in this... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false How are âmustâ and âshouldâ used in this part? 102-192.20 Section 102-192.20 Public Contracts and Property Management Federal...

  3. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  4. Limitations of Ir{sup 192} as a Radiographic Source for the Control of Reactor Pressure-Vessels; Limitations de {sup 192}Ir en Tant que Source pour l'Examen Radiographique des Caissons Etanches de Reacteurs; Nedostatki Iridiya-192 v kachestveradiograficheskogo istochnika dlya kontrolya za korpusami reaktorov vysokogodavleniya; Limitaciones del {sup 192}Ir como Fuente Radiografica en el Control de Recipientes de Presion para Reactores

    Energy Technology Data Exchange (ETDEWEB)

    Horvat, D. [Nuclear Institute ' ' J. Stefan' ' Ljubljana, Yugoslavia (Slovenia)

    1965-09-15

    Published data and the results of our own investigations have shown that the advantage of Ir{sup 192} with regard to the quality of radiographs is obvious when comparing it with Co{sup 60} even with thicknesses over 80 mm of irradiated steel. The application of Ir{sup 192} in practice is limited by the alternative: either a very long exposure time or a source of very high activity. Where the exposure (Ci. min) for 1 m of radiographed weld is plotted against the specific activity of the source, diagrams show that, for practically attainable specific activities kilo-curie sources must be used for greater thicknesses. For such sources, self-absorption may become an important factor. An analysis of the influence of self-absorption causing a reduction of the source effectiveness and the filtration effect in the source is made by determining an equivalent increase of thickness of irradiated steel and by calculating the effective linear absorption coefficient as a function of the source dimensions and the thickness of the irradiated steel. Even in cases of relatively large source dimensions the filtration effect does not diminish the effective linear absorption coefficient to such an extent that the advantage in quality against Co{sup 60} would be lost. Possibilities of improvement due to a new shape of radiographic sources are discussed. In the case of narrow primary beams these new sources give smaller effective dimensions and allow shorter source-to-film distances. A further advantage of Ir{sup 192} is obvious from the diagrams of the weight of the exposure equipment for Ir{sup 192} and Coso taking in account equivalent activities of both sources regarding the same exposure time. The economic disadvantages, because of the short half-life,of Ir{sup 192} are discussed and a rough economical comparison between Co{sup 60} and Ir{sup 192} at different extensiveness and densities of the radiographic control is given. (author) [French] Les donnees publiees et les resultats

  5. 49 CFR 192.373 - Service lines: Cast iron and ductile iron.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Cast iron and ductile iron. 192.373... Regulators, and Service Lines § 192.373 Service lines: Cast iron and ductile iron. (a) Cast or ductile iron... cast iron pipe or ductile iron pipe is installed for use as a service line, the part of the service...

  6. Low dose rate Ir-192 interstitial brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yosuke; Dokiya, Takushi; Yorozu, Atsunori; Suzuki, Takayuki; Saito, Shiro; Monma, Tetsuo; Ohki, Takahiro [National Tokyo Medical Center (Japan); Murai, Masaru; Kubo, Atsushi

    2000-04-01

    From December 1997 through January 1999, fifteen prostatic cancer patients were treated with low dose rate Ir-192 interstitial brachytherapy using TRUS and perineal template guidance without external radiotherapy. Up to now, as no apparent side effects were found, the safety of this treatment is suggested. In the future, in order to treat prostatic cancer patients with interstitial brachytherapy using I-125 or Pd-103, more investigation for this low dose rate Ir-192 interstitial brachytherapy is needed. (author)

  7. Rhenium(V) and technetium(V) complexes of bis(o-hydroxyphenyl)phenylphosphine (PO22-) and (o-hydroxyphenyl)diphenylphosphine (PO-) ligands

    International Nuclear Information System (INIS)

    Luo, Hongyan; Setyawati, Ika; Rettig, S.J.; Orvig, C.

    1995-01-01

    The synthesis of several phosphine-based chelating compounds and chelates formed between these compounds and rhenium or technetium is discussed. Four categories of products result, (i) bis-(o-hydroxyphenyl) diphenylphosphine (PO) complexes, (ii) mono- (PO) complexes, (iii) bis-bis(o-hydroxyphenyl)-phenylphosphine (PO 2 ) complexes, and mixed-(PO) and (PO 2 ) complexes. Molecular structures of these compounds (including isomers) were probed by NMR, MS, and IR spectroscopies and by X-ray crystallography

  8. Ultrafast Excited-State Dynamics of Rhenium(I) Photosensitizers [Re(Cl)(CO)3(N,N)] and [Re(imidazole)(CO)3(N,N)]+: Diimine Effects

    Czech Academy of Sciences Publication Activity Database

    Nahhas, A. E.; Consani, C.; Blanco-Rodríguez, A. M.; Lancaster, K. M.; Braem, O.; Cannizzo, A.; Towrie, M.; Clark, I. P.; Záliš, Stanislav; Chergui, M.; Vlček, Antonín

    2011-01-01

    Roč. 50, č. 7 (2011), s. 2932-2943 ISSN 0020-1669 R&D Projects: GA MŠk(CZ) ME10124; GA MŠk(CZ) LD11082 Institutional research plan: CEZ:AV0Z40400503 Keywords : rhenium * photosynthesis * diimine effects Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.601, year: 2011

  9. 49 CFR 192.65 - Transportation of pipe.

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.65 Transportation of pipe. (a) Railroad...

  10. 49 CFR 192.63 - Marking of materials.

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Materials § 192.63 Marking of materials. (a) Except as...

  11. 34 CFR 222.192 - What local funds may be considered as available for this project?

    Science.gov (United States)

    2010-07-01

    ... § 222.192 What local funds may be considered as available for this project? To determine the amount of... 34 Education 1 2010-07-01 2010-07-01 false What local funds may be considered as available for this project? 222.192 Section 222.192 Education Regulations of the Offices of the Department of...

  12. Rhenium-188: Availability from the W-188/Re-188 Generator and Status of Current Applications

    International Nuclear Information System (INIS)

    Pillai, M.R.A.; Dash, A.; Knapp, Russ F. Jr.

    2012-01-01

    Rhenium-188 is one of the most readily available generator derived and useful radionuclides for therapy emitting β-particles (2.12 MeV, 71.1% and 1.965 MeV, 25.6%) and imageable gammas (155 KeV, 15.1%). The 188W/188Re generator is an ideal source for the long term (4-6 months) continuous availability of no carrier added (nca) 188Re suitable for the preparation of radiopharmaceuticals for radionuclide therapy. The challenges associated with the double neutron capture route of production of the parent 188W radionuclide have been a major impediment in the progress of application of 188Re. Tungsten-188 of adequate specific activity can be prepared only in 2-3 of the high flux reactors operating in the World. Several useful technologies have been developed for the preparation of clinical grade 188W/188Re generator. Since the specific activity of 188W used in the generator is relatively low (<5 Ci/g), the eluted 188ReO4- can have low radioactive concentration often insufficient for radiopharmaceutical preparation. However, several efficient post elution concentration techniques have been developed that yield clinically useful 188ReO4-. Rhenium-188 has been used for the preparation of therapeutic radiopharmaceuticals for the management of diseases such as bone metastasis, rheumatoid arthritis and primary cancers. Several early phase clinical studies using radiopharmaceuticals based on 188Re-labeled phosphonates, antibodies, peptides, lipiodol and particulates have been reported. This article reviews the availability, and use of188Re including a discussion of why broader use of 188Re has not progressed as ecpected as a popular radionuclide for therapy.

  13. Radiation control in the intensive care unit for high intensity iridium-192 brain implants

    International Nuclear Information System (INIS)

    Sewchand, W.; Drzymala, R.E.; Amin, P.P.; Salcman, M.; Salazar, O.M.

    1987-01-01

    A bedside lead cubicle was designed to minimize the radiation exposure of intensive care unit staff during routine interstitial brain irradiation by removable, high intensity iridium-192. The cubicle shields the patient without restricting intensive care routines. The design specifications were confirmed by exposure measurements around the shield with an implanted anthropomorphic phantom simulating the patient situation. The cubicle reduces the exposure rate around an implant patient by as much as 90%, with the exposure level not exceeding 0.1 mR/hour/mg of radium-equivalent 192 Ir. Evaluation of data accumulated for the past 3 years has shown that the exposure levels of individual attending nurses are 0.12 to 0.36 mR/mg of radium-equivalent 192 Ir per 12-hour shift. The corresponding range for entire nursing teams varies between 0.18 and 0.26. A radiation control index (exposure per mg of radium-equivalent 192 Ir per nurse-hour) is thus defined for individual nurses and nursing teams; this index is a significant guide to the planning of nurse rotations for brain implant patients with various 192 Ir loads. The bedside shield reduces exposure from 192 Ir implants by a factor of about 20, as expected, and the exposure from the lower energy radioisotope iodine-125 is barely detectable

  14. Paraoxonase 1 Q192R (PON1-192) polymorphism is associated with reduced lipid peroxidation in healthy young men on a low-carotenoid diet supplemented with tomato juice.

    Science.gov (United States)

    Bub, Achim; Barth, Stephan W; Watzl, Bernhard; Briviba, Karlis; Rechkemmer, Gerhard

    2005-03-01

    The HDL-bound enzyme paraoxonase (PON) protects LDL from oxidation and may therefore attenuate the development of atherosclerosis. We examined the effect of tomato and carrot juice consumption on PON1 activity and lipid peroxidation in healthy young volunteers with different PON1-192 genotypes (Q/R substitution at position 192). In this randomized cross-over study twenty-two healthy, non-smoking men on a low-carotenoid diet received 330 ml/d tomato juice (37.0 mg lycopene, 1.6 mg beta-carotene) or carrot juice (27.1 mg beta-carotene, 13.1 mg alpha-carotene) for 2 weeks. Intervention periods were preceded by 2-week low-carotenoid intake. We determined the PON1-192 genotype by restriction fragment length polymorphism-polymerase chain reaction (RFLP-PCR) and measured ex vivo LDL oxidation (lag time), plasma malondialdehyde and PON1 activity at the beginning and end of each intervention period. At baseline, lag time was higher (Pjuice consumption had significant effects on PON1 activity. However, tomato juice consumption reduced (Pjuice had no significant effect on malondialdehyde irrespective of the PON1-192 genotype. Male volunteers with the QR/RR genotype showed an increased lipid peroxidation at baseline. Although tomato and carrot juice fail to affect PON1 activity, tomato juice intake reduced lipid peroxidation in healthy volunteers carrying the R-allele of the PON1-192 genotype and could thus contribute to CVD risk reduction in these individuals.

  15. Synthesis, characterization, and photophysical properties of a thiophene-functionalized bis(pyrazolyl) pyridine (BPP) tricarbonyl rhenium(I) complex.

    Science.gov (United States)

    Lytwak, Lauren A; Stanley, Julie M; Mejía, Michelle L; Holliday, Bradley J

    2010-09-07

    A bromo tricarbonyl rhenium(I) complex with a thiophene-functionalized bis(pyrazolyl) pyridine ligand (L), ReBr(L)(CO)(3) (1), has been synthesized and characterized by variable temperature and COSY 2-D (1)H NMR spectroscopy, single-crystal X-ray diffraction, and photophysical methods. Complex 1 is highly luminescent in both solution and solid-state, consistent with phosphorescence from an emissive (3)MLCT excited state with an additional contribution from a LC (3)(pi-->pi*) transition. The single-crystal X-ray diffraction structure of the title ligand is also reported.

  16. Evaluation of a new component used for isotopic lymphography: colloidal rhenium sulfide sup(99m)Tc labelled

    International Nuclear Information System (INIS)

    Pecking, A.; Le Mercier, N.; Gobin, R.; Bardy, A.; Najean, Y.

    1978-01-01

    We have studied for lymphatic scintigraphy a new radiopharmaceutical, sup(99m)Tc-labelled rhenium sulfocolloid. This preliminary study includes 20 adults patients with lymphomas and lymphoedemas. The principal advantage of this drug is its absence of toxicity and local pain, so that a rapid sub-cutaneous injection without local anesthesia is made possible. Good results have been obtained, as well in morphological studies of para-aortic and mammary lymph nodes as for kinetic studies of lymphatic flow in lymphoedemas. No liver and spleen uptake of radio-isotope was observed after foot injection [fr

  17. Polymer Photovoltaic Cells with Rhenium Oxide as Anode Interlayer.

    Science.gov (United States)

    Wei, Jinyu; Bai, Dongdong; Yang, Liying

    2015-01-01

    The effect of a new transition metal oxide, rhenium oxide (ReO3), on the performance of polymer solar cells based on regioregular poly(3-hexylthiophene) (P3HT) and methanofullerene [6,6]-phenyl C61-butyric acid methyl ester (PCBM) blend as buffer layer was investigated. The effect of the thickness of ReO3 layer on electrical characteristics of the polymer solar cells was studied. It is found that insertion of ReO3 interfacial layer results in the decreased performance for P3HT: PCBM based solar cells. In order to further explore the mechanism of the decreasing of the open-circuit voltage (Voc), the X-ray photoelectron spectroscopy (XPS) is used to investigate the ReO3 oxidation states. Kelvin Probe method showed that the work function of the ReO3 is estimated to be 5.13eV after thermal evaporation. The results indicated the fact that a portion of ReO3 decomposed during thermal evaporation process, resulting in the formation of a buffer layer with a lower work function. As a consequence, a higher energy barrier was generated between the ITO and the active layer.

  18. Influence of liposome forms of the rhenium compounds and cis-platin on thiol-disulfide coefficient in the rats’ blood

    Directory of Open Access Journals (Sweden)

    I. V. Klenina

    2007-12-01

    Full Text Available Thiol-disulfide coefficient (TDC and its different modifications in model in vivo were studied. Introduction of the liposome forms of cluster rhenium compounds with organic ligands (CROL leads to both TDC increasing and to the constancy of the TDC. Thus, CROLs aren’t toxic agents and some compounds could mobilize organisms’ thiol defence system. Liposome form of cis-platin leads to the TDC decreasing. Important CROL capacities for its future medical treatment practice were shown.

  19. Lump Kinetic Analysis of Syngas Composition Effect on Fischer-Tropsch Synthesis over Cobalt and Cobalt-Rhenium Alumina Supported Catalyst

    Directory of Open Access Journals (Sweden)

    Dewi Tristantini

    2016-03-01

    Received: 10th November 2015; Revised: 10th February 2016; Accepted: 16th February 2016 How to Cite: Tristantini, D., Suwignjo, R.K. (2016. Lump Kinetic Analysis of Syngas Composition Effect on Fischer-Tropsch Synthesis over Cobalt and Cobalt-Rhenium Alumina Supported Catalyst. Bulletin of Chemical Reaction Engineering & Catalysis, 11 (1: 84-92. (doi:10.9767/bcrec.11.1.424.84-92 Permalink/DOI: http://dx.doi.org/10.9767/bcrec.11.1.424.84-92

  20. 188Rhenium-HEDP in the treatment of pain in bone metastases

    International Nuclear Information System (INIS)

    Gaudiano, J.; Martinez, G.; Hermida, J.C.; Savio, E.; Verdera, S.; Robles, A.; Muniz, S.; Leon, A.; Knapp, F.F.

    2001-01-01

    Systemic use of radiopharmaceuticals is a recognised alternative method for the treatment of pain in patients with multiple bone metastases. A new option, 188 Re-HEDP is proposed, using generator-obtained 188 Rhenium (β energy = 2.1 MeV, γ energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastases from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities. (author)

  1. 188Rhenium-HEDP in the Treatment of Pain in Bone Metastases

    International Nuclear Information System (INIS)

    Gaudiano, J.; Savio, E.; Robles, A.; Muniz, S.; Leon, A.; Verdera, S.; Martinez, G.; Hermida, J.C.; Knapp, F.F. Jr.

    1999-01-01

    Systemic use of radiopharmaceuticals is a recognized alternative method for the treatment of pain in patients with multiple bone metastasis. A new option, 188 Re-HEDP is proposed, using generator-obtained 188 Rhenium (β energy = 2.1 MeV, γ energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastasis from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities

  2. Studies on the preparation and isomeric composition of [sup 186]Re- and [sup 188]Re-pentavalent rhenium dimercaptosuccinic acid complex

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J. (Canterbury Univ. (United Kingdom). Biological Lab.); Reghebi, K.; Lazarus, C.R.; Clarke, S.E.M. (Guy' s Hospital, London (United Kingdom)); Callahan, A.P.; Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Blower, P.J. (Kent and Canterbury Hospital (United Kingdom))

    1993-03-01

    The preparative conditions for [sup 186]Re(V)DMSA and [sup 188]Re(V)DMSA (DMSA = meso-dimercaptosuccinic acid), [beta]-emitting radiopharmaceuticals that have been shown to localize in medullary thyroid carcinoma, require modification depending on the amount of carrier rhenium and the chemical form and medium in which the rhenium is supplied. Preparative conditions are described for use with carrier-free [sup 188]ReO[sub 4][sup -] in saline, and for use with [sup 186]ReO[sub 4][sup -] in saline, sodium hydroxide or nitric acid. Preparation of [sup 186]Re(V)DMSA (carrier present up to 2 mg per 2.5 ml reaction volume) requires a DMSA:SnCl[sub 2]:Re ratio of 10:5:1 at 100[sup o]C for 30 min. Addition of excess nitric acid or hydrochloric acid up to a concentration of 155 mM does not reduce the yield from 100%. A commercial DMSA kit vial (e.g. Amerscan DMSA) can be used for preparation of [sup 188]Re(V)DMSA (carrier free) provided the required is in a volume of less than 1 ml per vial. A convenient method of concentrating the [sup 188]Re generator eluate to the required volume is described. (Author).

  3. 49 CFR 192.197 - Control of the pressure of gas delivered from high-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Control of the pressure of gas delivered from high-pressure distribution systems. 192.197 Section 192.197 Transportation Other Regulations Relating to... STANDARDS Design of Pipeline Components § 192.197 Control of the pressure of gas delivered from high...

  4. 192Ir Intraluminal brachytherapy for the prevention of urethral re-stricture

    International Nuclear Information System (INIS)

    Ma Changuo; Guo Hui; Du Chun; Yang Keqiang

    2008-01-01

    Objective: To evaluate the safety and efficacy of 192 Ir intraluminal brachytherapy for the prevention of urethral restricture after transurethral incision or transurethral resection of scar. Methods: From Mar. 2004 to Jun. 2006, 48 patients aging 18-81 years were treated by 192 Ir intraluminal brachytherapy. The length of stricture(0.5-5.5 cm) was ≤3.0 cm in 90% of the patients. The stricture was caused by trauma in 23 patients and prostate hyperplasia operation in 19 patients. The cause of remaining 6 patients was unclear. All patients were diagnosed by urethra photograph or endoscopy. Radiotherapy was the initial treatment in 26 patients and the second time treatment in 22. The irradiation dose was from 14 Gy to 18 Gy. Results: The median follow up was 10 months, and the total response rate was 98%. Only one patient recurred and received transurethral incision again. The uresis was fluency in 47 patients and the maximum flow rate was 13.9-36.4 (19.2 ± 10.3) ml/s. No secondary urethral bleeding or urethral cancer was observed. Conclusions: Being a safe and feasible treatment, 192 Ir intraluminal brachytherapy following transurethral incision or transurethral resection of scar can effectively prevent urethral re-stricture. (authors)

  5. Production of iridium-192 radiation sources: Indian Experience

    International Nuclear Information System (INIS)

    Sastry, K.V.S.; Kolhe, O.T.; Nagarja, P.S.; Paramr, Y.D.

    2002-01-01

    Board of Radiation and Isotope Technology (BRIT), a unit under the Department of Atomic Energy is fabricating and supplying Ir-192 industrial radiography sources for various models of radiography cameras for use in the industry for non-destructive testing. Basically these sources are fabricated by encapsulating the required quantity of the activity in stainless steel 316 L capsules using Tungsten Inert gas welding process and crimping/attaching to the respective pigtail assemblies of the radiography cameras. The inactive iridium pellets are irradiated in the DHRUVA reactor at a flux on 1.8 X 10 14 n/cm 2 /sec. The performance classification of these source encapsulation for various conditions of normal and accidental nature are tested by subjecting the prototype sources as per the standard laid down by the regulatory authority, Atomic Energy Regulatory Board, in India. The sources are fabricated as per the national and international standards. Activity of the sources varies from 37O GBq (10 Ci ) to 2.96 TBq (80 Ci ) source strength depending on the requirement of the user. The specific activity of the Ir-192 sources supplied is around 7.4 TBq/gm (200 Ci/gm ). Quality control /Assurance for the manufacture of the source begins from the procurement of the raw material and ends with the finished source. Ir- 192 in the form of -0.3 mm diameter (0.1 mm dia wire of Ir-25 % and Pt-75% sheathed in pure platinum of 0.1 mm thick) is being supplied for use in the treatment of cancer of cervix, tongue etc. by brachytherapy. This is supplied in lengths of 50 cm / 100 cm with 37 - 185 GBq/cm ( 1-5 mCi/cm) activity. Annually 925 TBq (25 kCi) of Ir-192 for industrial radiography and about 60 meters of wire for brachytherapy are being fabricated and supplied. Because of the quality of these sources BRIT not only caters to the Indian industry but also is able to export sources to the third world countries. (Author)

  6. 22 CFR 192.32 - Administration of benefits.

    Science.gov (United States)

    2010-04-01

    ....32 Foreign Relations DEPARTMENT OF STATE HOSTAGE RELIEF VICTIMS OF TERRORISM COMPENSATION Medical... behalf thereof, shall submit an application to the Office of Medical Services, Department of State..., on behalf of the Secretary of State, whether the care in question is authorized under § 192.31 of...

  7. 49 CFR 192.229 - Limitations on welders.

    Science.gov (United States)

    2010-10-01

    ... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.229 Limitations on welders. (a) No welder whose qualification is based on nondestructive testing may weld compressor station pipe and components. (b) No welder may weld with a particular welding process unless, within the...

  8. 41 CFR 102-192.100 - How do we submit our annual mail management report to GSA?

    Science.gov (United States)

    2010-07-01

    ... management report to GSA? If your agency is a large agency, as defined in § 102-192.35, you must submit... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false How do we submit our annual mail management report to GSA? 102-192.100 Section 102-192.100 Public Contracts and Property...

  9. Synthesis, structural characterization and photoluminescence properties of rhenium(I) complexes based on bipyridine derivatives with carbazole moieties.

    Science.gov (United States)

    Li, Hong-Yan; Wu, Jing; Zhou, Xin-Hui; Kang, Ling-Chen; Li, Dong-Ping; Sui, Yan; Zhou, Yong-Hui; Zheng, You-Xuan; Zuo, Jing-Lin; You, Xiao-Zeng

    2009-12-21

    Three N,N-bidentate ligands, 5,5'-dibromo-2,2-bipyridine (L1) and two carbazole containing ligands of 5-bromo-5'-carbazolyl-2,2-bipyridine (L2), 5,5'-dicarbazolyl-2,2'-bipyridine (L3), and their corresponding rhenium Re(CO)3Cl(L) complexes (ReL1-ReL3) have been successfully synthesized and characterized by elemental analysis, 1H NMR and IR spectra. Their photophysical properties and thermal analysis, along with the X-ray crystal structure analysis of L3 and complexes ReL1 and ReL3 are also described. In CH2Cl2 solution at room temperature, all complexes display intense absorption bands at ca. 220-350 nm, which can be assigned to spin-allowed intraligand (pi-->pi*) transitions, and the low energy broad bands in the 360-480 nm region are attributed to the metal to ligand charge-transfer d(Re)-->pi* (diimine) (MLCT). The introduction of carbazole moieties improves the MLCT absorption and molar extinction coefficient of these complexes. Upon excitation at the peak maxima, all complexes show strong emissions around 620 nm, which are assigned to d(Re)-->pi* (diimine) MLCT phosphorescence. The photoluminescence lifetime decay of Re(I) complexes were measured and the quantum efficiencies of the rhenium(I) complexes were calculated by using air-equilibrated [Ru(bpy)3]2+ x 2 Cl- aqueous solution as standard (phi(std) = 0.028). The complexes with appended carbazole moieties exhibit enhanced luminescence performances relative to ReL1.

  10. 41 CFR 102-192.145 - Which program levels should have a mail manager?

    Science.gov (United States)

    2010-07-01

    ... should have a mail manager? 102-192.145 Section 102-192.145 Public Contracts and Property Management... have a mail manager? Every program level within a Federal agency that generates a significant quantity of outgoing mail should have its own mail manager. Each agency must decide which programs will have a...

  11. Influence of source geometry and materials on the transverse axis dosimetry of 192Ir brachytherapy sources

    International Nuclear Information System (INIS)

    Wang, Ruqing; Sloboda, Ron S.

    1998-01-01

    Monte Carlo dose rates on the transverse axis in water and air kerma strengths normalized to unit source activity were calculated for a low dose rate steel-clad 192 Ir source, MicroSelectron high dose rate and pulsed dose rate 192 Ir sources, and a VariSource high dose rate 192 Ir source, as well as five other hypothetical cylindrical 192 Ir source designs. Based on these results, the dependence of dose rate and air kerma strength on source geometry and materials was analysed. Source geometry and attenuation in the core material are the important factors determining basic dosimetric characteristics. Core length, h, only affects the dose rate on the transverse axis at radial distances r 192 Ir sources is suggested, and similarities and differences in the dose rate constant and radial dose function between these sources are explained. (author)

  12. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  13. Traceable calibration of hospital 192Ir HDR sources

    International Nuclear Information System (INIS)

    Govinda Rajan, K.N.; Sharma, S.D.; Palaniselvam, T.; Vandana, S.; Bhatt, B.C.; Vinatha, S.; Patki, V.S.; Pendse, A.M.; Kannan, V.

    2004-01-01

    A HDR 1000 PLUS well type ionization chamber, procured from Standard Imaging, USA, and maintained by medical Physics and Safety Section (MPSS), Bhabha Atomic Research Centre (BARC), India, as a reference well chamber 1 (RWCH1), was traceably calibrated against the primary standard established by Radiological Standards Laboratory (RSL), BARC for 192 Ir HDR source, in terms of air kerma strength (AKS). An indigenously developed well-type ionization chamber, reference well chamber 2 (RWCH2) and electrometer system, fabricated by CD High Tech (CDHT) Instruments Private Ltd., Bangalore, India, was in turn calibrated against RWCH1. The CDHT system (i.e. RWCH2 and CDHT electrometer system) was taken to several hospitals, in different regions of the country, to check the calibration status of 192 Ir HDR sources. The result of this calibration audit work is reported here. (author)

  14. Determination of rhenium in biological and environmental samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Mizera, J.; Randa, Z.; Byrne, A.R.; Lucanikova, M.

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1 M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1 M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng.g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng.g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of approx. 10 ng.g -1 was found. Significantly elevated values of Re, up to 90 ng.g -1 , were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggest possible competition between Re and Tc in the accumulation process. (author)

  15. 15 CFR 19.2 - Why has the Commerce Department issuing these regulations and what do they cover?

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Why has the Commerce Department issuing these regulations and what do they cover? 19.2 Section 19.2 Commerce and Foreign Trade Office of the Secretary of Commerce COMMERCE DEBT COLLECTION General Provisions § 19.2 Why has the Commerce...

  16. {sup 188}Rhenium-HEDP in the Treatment of Pain in Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Gaudiano, J.; Savio, E.; Robles, A.; Muniz, S.; Leon, A.; Verdera, S.; Martinez, G.; Hermida, J.C.; Knapp, F.F., Jr.

    1999-01-18

    Systemic use of radiopharmaceuticals is a recognized alternative method for the treatment of pain in patients with multiple bone metastasis. A new option, {sup 188}Re-HEDP is proposed, using generator-obtained {sup 188}Rhenium ({beta} energy = 2.1 MeV, {gamma} energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastasis from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities.

  17. Evaluation of the Radiological Safety of 192 Ir Apparatus for Industrial Gamma Radiography

    International Nuclear Information System (INIS)

    Aquino, J. O.; Silva, F. C. A. da; Ramalho, A. T.; Godoy, J. M. O.

    2004-01-01

    The majority of the 192Ir apparatus for industrial gamma radiography have been in usage in Brazil for more than 20 years. They are portable, and almost all operate according to category II. The main objective of this work was to assess the radiological safety of the 11 models of 192Ir apparatus most used in Brazil. The 11 models of 192Ir apparatus were studied with respect to compliance with the main safety requirements of three editions of international Standards ISO 3999. Six models were already manufactured incorporating the safety devices specified in the first edition of ISO 3999, issued in 1977. However, five models were not. The validity of their type B certificates for transport packages was also evaluated. (Author) 8 refs

  18. Identification of rhenium donors and sulfur vacancy acceptors in layered MoS{sub 2} bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Brandão, F. D., E-mail: fdbrand@fisica.ufmg.br; Ribeiro, G. M.; Vaz, P. H.; González, J. C.; Krambrock, K. [Departamento de Física, Universidade Federal de Minas Gerais, CP 702, 30.123-970 Belo Horizonte, MG (Brazil)

    2016-06-21

    MoS{sub 2} monolayers, a two-dimensional (2D) direct semiconductor material with an energy gap of 1.9 eV, offer many opportunities to be explored in different electronic devices. Defects often play dominant roles in the electronic and optical properties of semiconductor devices. However, little experimental information about intrinsic and extrinsic defects or impurities is available for this 2D system, and even for macroscopic 3D samples for which MoS{sub 2} shows an indirect bandgap of 1.3 eV. In this work, we evaluate the nature of impurities with unpaired spins using electron paramagnetic resonance (EPR) in different geological macroscopic samples. Regarding the fact that monolayers are mostly obtained from natural crystals, we expect that the majority of impurities found in macroscopic samples are also randomly present in MoS{sub 2} monolayers. By EPR at low temperatures, rhenium donors and sulfur vacancy acceptors are identified as the main impurities in bulk MoS{sub 2} with a corresponding donor concentration of about 10{sup 8–12} defects/cm{sup 2} for MoS{sub 2} monolayer. Electrical transport experiments as a function of temperature are in good agreement with the EPR results, revealing a shallow donor state with an ionization energy of 89 meV and a concentration of 7 × 10{sup 15 }cm{sup −3}, which we attribute to rhenium, as well as a second deeper donor state with ionization energy of 241 meV with high concentration of 2 × 10{sup 19 }cm{sup −3} and net acceptor concentration of 5 × 10{sup 18 }cm{sup −3} related to sulfur vacancies.

  19. Hydrodeoxygenation of vicinal OH groups over heterogeneous rhenium catalyst promoted by palladium and ceria support.

    Science.gov (United States)

    Ota, Nobuhiko; Tamura, Masazumi; Nakagawa, Yoshinao; Okumura, Kazu; Tomishige, Keiichi

    2015-02-02

    Heterogeneous ReOx-Pd/CeO2 catalyst showed excellent performance for simultaneous hydrodeoxygenation of vicinal OH groups. High yield (>99%), turnover frequency (300 h(-1)), and turnover number (10,000) are achieved in the reaction of 1,4-anhydroerythritol to tetrahydrofuran. This catalyst can be applied to sugar alcohols, and mono-alcohols and diols are obtained in high yields (≥85%) from substrates with even and odd numbers of OH groups, respectively. The high catalytic performance of ReOx-Pd/CeO2 can be assigned to rhenium species with +4 or +5 valence state, and the formation of this species is promoted by H2/Pd and the ceria support. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Photodetectors: Broad Detection Range Rhenium Diselenide Photodetector Enhanced by (3-Aminopropyl)Triethoxysilane and Triphenylphosphine Treatment (Adv. Mater. 31/2016).

    Science.gov (United States)

    Jo, Seo-Hyeon; Park, Hyung-Youl; Kang, Dong-Ho; Shim, Jaewoo; Jeon, Jaeho; Choi, Seunghyuk; Kim, Minwoo; Park, Yongkook; Lee, Jaehyeong; Song, Young Jae; Lee, Sungjoo; Park, Jin-Hong

    2016-08-01

    The effects of triphenylphosphine (PPh3 ) and (3-amino-propyl)triethoxysilane (APTES) on a rhenium diselenide (ReSe2 ) photodetector are systematically studied by J.-H. Park and co-workers on page 6711 in comparison with a conventional MoS2 device. A very high performance ReSe2 photodetector is demonstrated, which has a broad photodetection range, high photoresponsivity (1.18 × 10(6) A W(-1) ), and fast photoswitching speed (rising/decaying time: 58/263 ms). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Effect of heat-treatment on microstructure and high-temperature deformation behavior of a low rhenium-containing single crystal nickel-based superalloy

    International Nuclear Information System (INIS)

    Sun, Nairong; Zhang, Lanting; Li, Zhigang; Shan, Aidang

    2014-01-01

    A low rhenium-containing [001] oriented single crystal nickel-based superalloy with different γ′ morphologies induced by various aging treatments was compressed from room temperature to 1000 °C. All the single crystal samples with different γ′ morphologies exhibit anomalous yield behavior. The sample first aged at 1180 °C has the widest anomalous temperature domain and highest yield strengths. The sample first aged at 1000 °C has the highest anomalous peak stress temperature

  2. 49 CFR 192.369 - Service lines: Connections to cast iron or ductile iron mains.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Connections to cast iron or ductile iron mains. 192.369 Section 192.369 Transportation Other Regulations Relating to Transportation... ductile iron mains. (a) Each service line connected to a cast iron or ductile iron main must be connected...

  3. A Fluorine-18 Radiolabeling Method Enabled by Rhenium(I) Complexation Circumvents the Requirement of Anhydrous Conditions.

    Science.gov (United States)

    Klenner, Mitchell A; Pascali, Giancarlo; Zhang, Bo; Sia, Tiffany R; Spare, Lawson K; Krause-Heuer, Anwen M; Aldrich-Wright, Janice R; Greguric, Ivan; Guastella, Adam J; Massi, Massimiliano; Fraser, Benjamin H

    2017-05-11

    Azeotropic distillation is typically required to achieve fluorine-18 radiolabeling during the production of positron emission tomography (PET) imaging agents. However, this time-consuming process also limits fluorine-18 incorporation, due to radioactive decay of the isotope and its adsorption to the drying vessel. In addressing these limitations, the fluorine-18 radiolabeling of one model rhenium(I) complex is reported here, which is significantly improved under conditions that do not require azeotropic drying. This work could open a route towards the investigation of a simplified metal-mediated late-stage radiofluorination method, which would expand upon the accessibility of new PET and PET-optical probes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. 49 CFR 192.153 - Components fabricated by welding.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Components fabricated by welding. 192.153 Section....153 Components fabricated by welding. (a) Except for branch connections and assemblies of standard... welding, whose strength cannot be determined, must be established in accordance with paragraph UG-101 of...

  5. In-situ field-ion microscope study of the recovery behavior of heavy metal ion-irradiated tungsten, tungsten (rhenium) alloys and molybdenum

    International Nuclear Information System (INIS)

    Nielsen, C.H.

    1977-06-01

    Three field ion microscope (FIM) experiments were carried out to study the annealing behavior of heavy ion irradiated tungsten, tungsten (rhenium) alloys and molybdenum. The first experiment dealt with the stage I long-range migration of tungsten self interstitial atoms (SIAs) in high purity tungsten of resistivity ratio, R = 24,000 (R = rho 300 /rho 4 . 2 , where rho 300 and rho 4 . 2 are the room temperature and 0 0 C resistivities). The FIM specimens were irradiated in situ at 18 K with 30 keV W + ions to an average dose of 5 x 10 12 ions cm -2 and subsequently examined by the pulsed-field evaporation technique. The second experiment dealt with the phenomenon of impurity atom trapping of SIAs during long-range migration. It was shown that rhenium atoms in a tungsten matrix tend to capture tungsten SIAs and remain bound up to temperatures as high as 390 K. The final experiment was concerned with the low temperature annealing kinetics of irradiated molybdenum. High purity molybdenum of resistivity ratio R = 5700 was irradiated at 10 K with 30 keV Mo + ions to a dose of approximately 5 x 10 12 ions cm -2 . The results indicated that the electric field has only a minimal effect on the SIA annealing kinetics. This tends to strengthen the contention that the molybdenum SIA becomes mobile at 32 K

  6. Toxicity of chlorpyrifos and chlorpyrifos oxon in a transgenic mouse model of the human paraoxonase (PON1) Q192R polymorphism

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Toby B.; Walter, Betsy J.; Shih, Diana M.; Tward, Aaron D.; Lusis, Aldons J.; Timchalk, Chuck; Richter, Rebecca J.; Costa, Lucio G.; Furlong, Clement E.

    2005-08-01

    The Q192R polymorphism of paraoxonase (PON1) has been shown to affect hydrolysis of organophosphorus compounds. The Q192 and R192 alloforms exhibit equivalent catalytic efficiencies of hydrolysis for diazoxon, the oxon form of the pesticide (DZ). However, the R192 alloform has a higher catalytic efficiency of hydrolysis than does the Q192 alloform for chlorpyrifos oxon (CPO), the oxon form of the pesticide chlorpyrifos (CPS). The current study examined the relevance of these observations for in-vivo exposures to chlorpyrifos and chlorpyrifos oxon. Methods Using a transgenic mouse model we examined the relevance of the Q192R polymorphism for exposure to CPS and CPO in vivo. Transgenic mice were generated that expressed either human PON1Q192 or PON1R192 at equivalent levels, in the absence of endogenous mouse PON1. Dose-response and time course experiments were performed on adult mice exposed dermally to CPS or CPO. Morbidity and acetylcholinesterase (AChE) activity in the brain and diaphragm were determined in the first 24 h following exposure. Results Mice expressing PON1Q192 were significantly more sensitive to CPO, and to a lesser extent CPS, than were mice expressing PON1R192. The time course of inhibition following exposure to 1.2 mg/kg CPO revealed maximum inhibition of brain AChE at 6?12 h, with PON1R192, PON1Q192, and PON1? /? mice exhibiting 40, 70 and 85% inhibition, respectively, relative to control mice. The effect of PON1 removal on the dose?response curve for CPS exposure was remarkably consistent with a PBPK/PD model of CPS exposure. Conclusion These results indicate that individuals expressing only the PON1Q192 allele would be more sensitive to the adverse effects of CPO or CPS exposure, especially if they are expressing a low level of plasma PON1Q192.

  7. A randomised, phase II study of repeated rhenium-188-HEDP combined with docetaxel and prednisone versus docetaxel and prednisone alone in castration-resistant prostate cancer (CRPC) metastatic to bone; the Taxium II trial

    Energy Technology Data Exchange (ETDEWEB)

    Dodewaard-de Jong, Joyce M. van [VU University Medical Centre, Department of Medical Oncology, Amsterdam (Netherlands); Meander Medical Centre, Department of Medical Oncology, Amersfoort (Netherlands); Klerk, John M.H. de [Meander Medical Centre, Department of Nuclear Medicine, Amersfoort (Netherlands); Bloemendal, Haiko J. [Meander Medical Centre, Department of Medical Oncology, Amersfoort (Netherlands); University Medical Centre Utrecht, Department of Medical Oncology, Utrecht (Netherlands); Oprea-Lager, Daniela E.; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Berg, H.P. van den [Tergooi Medical Hospital, Department of Medical Oncology, Hilversum (Netherlands); Los, Maartje [St Antonius Hospital Utrecht, Department of Medical Oncology, Utrecht (Netherlands); Beeker, Aart [Spaarne Gasthuis, Department of Medical Oncology, Hoofddorp (Netherlands); Jonker, Marianne A. [VU University Medical Centre, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); O' Sullivan, Joe M. [Queen' s University Belfast, Centre for Cancer Research and Cell Biology, Belfast, Northern Ireland (United Kingdom); Verheul, Henk M.W.; Eertwegh, Alfons J.M. van den [VU University Medical Centre, Department of Medical Oncology, Amsterdam (Netherlands)

    2017-08-15

    Rhenium-188-HEDP is a beta-emitting radiopharmaceutical used for palliation of metastatic bone pain. We investigated whether the addition of rhenium-188-HEDP to docetaxel/prednisone improved efficacy of chemotherapy in patients with CRPC. Patients with progressive CRPC and osteoblastic bone metastases were randomised for first-line docetaxel 75 mg/m{sup 2} 3-weekly plus prednisone with or without 2 injections of rhenium-188-HEDP after the third (40 MBq/kg) and after the sixth (20 MBq/kg) cycle of docetaxel. Primary endpoint was progression-free survival (PFS), defined as either PSA, radiographic or clinical progression. Patients were stratified by extent of bone metastases and hospital. Forty-two patients were randomised for standard treatment and 46 patients for combination therapy. Median number of cycles of docetaxel was 9 in the control group and 8 in the experimental group. Median follow-up was 18.4 months. Two patients from the experimental group did not start treatment after randomisation. In the intention to treat analysis no differences in PFS, survival and PSA became apparent between the two groups. In an exploratory per-protocol analysis median overall survival was significantly longer in the experimental group (33.8 months (95%CI 31.75-35.85)) than in the control group (21.0 months (95%CI 13.61-28.39); p 0.012). Also median PFS in patients with a baseline phosphatase >220U/L was significantly better with combination treatment (9.0 months (95%CI 3.92-14.08) versus 6.2 months (95%CI 3.08-9.32); log rank p 0.005). As expected, thrombocytopenia (grade I/II) was reported more frequently in the experimental group (25% versus 0%). Combined treatment with rhenium-188-HEDP and docetaxel did not prolong PFS in patients with CRPC. The observed survival benefit in the per-protocol analysis warrants further studies in the combined treatment of chemotherapy and radiopharmaceuticals. (orig.)

  8. Dose calculation for iridium-192 sources by a personal computer

    International Nuclear Information System (INIS)

    Takahashi, Kenichi; Ishigaki, Hideyo; Udagawa, Kimio; Saito, Masami; Yamaguchi, Kyoko

    1988-01-01

    Recently Ir-192 sources have been used for interstitial radiotherapy instead of Ra-226 needles. One end of Ir-192 (single-pin) is formed with circlet and implanted Ir-192 sources are not always straight line. So the authors have developed a new dose calculation system, in which the authers employed conventional method considering oblique filteration for linear source and multi-point source method for curved source. Conventionally the positions of sources in three dimensions are determined from projections of the implanted sources on orthogonal or stereo radiographs. But it is frequentry impossible to define the end of sources on account of overlap. Then the authers have devised a method to determine the positions of sources from two radiographs which were taken with arbitrary directions. For tongue cancer injuries of mandibula so frequently occur after interstitial radiotherapy that the calculation of gingival dose is necessary. The positions of the gingival line are determined from two directional radiographs too. Further the three dimensional dose distributions can be displayed on the cathod ray tube. These calculations are performed by using a personal computer because of its distinctive features such as superiority in cost performance and flexibility for development and modification of programs. (author)

  9. Industrial radiography with Ir-192 using computed radiographic technique

    International Nuclear Information System (INIS)

    Ngernvijit, Narippawaj; Punnachaiya, Suvit; Chankow, Nares; Sukbumperng, Ampai; Thong-Aram, Decho

    2003-01-01

    The aim of this research is to study the utilization of a low activity Ir-192 gamma source for industrial radiographic testing using the Computed Radiography (CR) system. Due to a photo-salbutamol Imaging Plate (I P) using in CR is much more radiation sensitive than a type II film with lead foil intensifying screen, the exposure time with CR can be significantly reduced. For short-lived gamma-ray source like Ir-192 source, the exposure time must be proportionally increased until it is not practical particularly for thick specimens. Generally, when the source decays to an activity of about 5 Ci or less, it will be returned to the manufacturer as a radioactive waste. In this research, the optimum conditions for radiography of a 20 mm thick welded steel sample with 2.4 Ci Ir-192 was investigated using the CR system with high resolution image plate, i.e. type Bas-SR of the Fuji Film Co. Ltd. The I P was sandwiched by a pair of 0.25 mm thick Pb intensifying sere en. Low energy scattered radiations was filtered by placing another Pb sheet with a thickness of 3 mm under the cassette. It was found that the CR image could give a contrast sensitivity of 2.5 % using only 3-minute exposure time which was comparable to the image taken by the type II film with Pb intensifying screen using the exposure time of 45 minutes

  10. Study of transition probabilities in 192Pt

    International Nuclear Information System (INIS)

    Roulet, C.; Sergolle, H.; Hubert, P.P.; Lindblad, T.

    1978-01-01

    The nucleus 192 Pt is Coulomb excited with 370 MeV 84 Kr projectiles. Levels up to spin 8 + (10 + ) in the ground band and up to 6 + in the γ-band are observed. The B(E2) values implied by the observed yields are compared with predictions of different nuclear models. Particular attention is paid to the ground band transition rates and the rotation-alignment model

  11. [Relationship between Q192R polymorphisms in paraoxonase 1 gene and young ischemic stroke].

    Science.gov (United States)

    Liu, Jing-li; Li, Jin-pin; Wang, Xiao-ling; Yang, Yi

    2010-04-06

    To investigate the relationship between polymorphisms in paraoxonase1 (PON1) gene Gln192Arg (Q192R) and arterial ischemic stroke in young adults. The Q192R genotype was analyzed by polymerase chain reaction in 131 young adults with ischemic stroke and 135 age- and gender-matched controls. The plasma lipids were also determined in patients and controls respectively. Furthermore, carotid artery intima-media thickness (IMT) in patients were measured by carotid ultrasonography. The distributions of Q192R genotype frequency were significantly different between patients with ischemic stroke and control individuals. And the patients had more RR genotypes than control individuals (P stroke were 1.743 (95% confidence interval [CI], 1.032-2.943) in subjects with RR genotype. We also studied the relationship between the polymorphisms and the lipid concentration in patients and control individuals. However, no significant association was detected between Q/R192 genotype and any of lipid measurements. Further, the prevalence of cigarette smoking, hypertension and diabetes showed no significant difference between RR and non-RR genotypes in patients. Body mass index (BMI) in two groups did not differ significantly. But IMT of patients with RR genotype obviously increased in comparison to those without RR genotype (P ischemic stroke in young adults. RR genotype is a genetic risk for young adults with ischemic stroke through an increased carotid artery intima-media thickness and an accelerated atherosclerotic process.

  12. Gamma bands in doubly odd rhenium and iridium nuclei

    Directory of Open Access Journals (Sweden)

    Balodis M.

    2015-01-01

    Full Text Available Structure of the |K ± 2| bands in doubly-odd nuclei belonging to the transitional deformation region at A∼190 is discussed. Relation of these quasi gamma-bands with the non-axial deformation of the parent two-quasiparticle configurations is studied. Using available experimental information, new tentative |K ± 2| bands are proposed in 188Re, and 192,194Ir nuclei. Coexistence of two-quasiparticle states with different deformation modes is considered in the case of 188Re and 194Ir.

  13. Active and passive vectorization of technetium99m and 188rhenium radiopharmaceuticals for medical imaging and radiotherapy

    International Nuclear Information System (INIS)

    Lepareur, N.

    2003-11-01

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes 186 Re and 188 Re, owing to their ideal properties and their similitude with 99m Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium 99m based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the 188 Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this 188 Re-SSS lipiodol and of its analogue 99m Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  14. Rhenium complexes of chromophore-appended dipicolylamine ligands: syntheses, spectroscopic properties, DNA binding and X-ray crystal structure

    International Nuclear Information System (INIS)

    Mullice, L.A.; Buurma, N.J.; Pope, S.J.A.; Laye, R.H.; Harding, L.P.

    2008-01-01

    The syntheses of two chromophore-appended dipicolylamine-derived ligands and their reactivity with penta-carbonyl-chloro-rhenium have been studied. The resultant complexes each possess the fac-Re(CO) 3 core. The ligands L 1 1-[bis(pyridine-2-yl-methyl)amino]methyl-pyrene and L 2 2-[bis(pyridine-2-yl-methyl)amino]methyl-quinoxaline were isolated via a one-pot reductive amination in moderate yield. The corresponding rhenium complexes were isolated in good yields and characterised by 1 H NMR, MS, IR and UV-Vis studies. X-Ray crystallographic data were obtained for fac-{Re(CO) 3 (L 1 )}(BF 4 ), C 34 H 26 BF 4 N 4 O 3 Re: monoclinic, P2(1)/c, a 18.327(2) Angstroms, α = 90.00 degrees, b 14.1537(14) Angstroms, β96.263(6) degrees, c = 23.511(3) Angstroms, γ 90.00 Angstroms, 6062.4(11) (Angstroms) 3 , Z=8. The luminescence properties of the ligands and complexes were also investigated, with the emission attributed to the appended chromophore in each case. Isothermal titration calorimetry suggests that fac-{Re(CO) 3 (L 1 )}(BF 4 ) self-aggregates cooperatively in aqueous solution, probably forming micelle-like aggregates with a cmc of 0.18 mM. Investigations into the DNA-binding properties of fac-{Re(CO) 3 (L 1 )}(BF 4 ) were undertaken and revealed that fac-{Re(CO) 3 (L 1 )}(BF 4 ) binding to fish sperm DNA (binding constant 1.5 ± 0.2 * 10 5 M -1 , binding site size 3.2 ± 0.3 base pairs) is accompanied by changes in the UV-Vis spectrum as typically observed for pyrene-based intercalators while the calorimetrically determined binding enthalpy (-14 ± 2 kcal mol -1 ) also agrees favourably with values as typically found for intercalators. (authors)

  15. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-01-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current–voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research. PMID:27819264

  16. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-11-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current-voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research.

  17. Thermal transformations of oxohalide complexes of rhenium(5) and molybdenum(5) with diazo-18-crown-6 in solid phase

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.

    1992-01-01

    Methods for synthesis and separation in solid state of the rhenium(5) and molybdenum(5) onium complexes with diaza-18-crown-6(L), the content of which according to the data of elementary analysis, IRS in the close and remote areas, thermogravimetry, conductometry and potentiometry corresponds to the (H 2 L)[EOX 5 ], where E = Re, Mo; X = Cl - , Br - . Thermotransformation of onium compounds is studied by methods of thermal methods (TG-DTG-DTA combined study). Their avility to be affected by solid-phase dehydrohalogenization, e.i. anderson regrouping. The thermolysis products, corresponding to the general formula (EOLX 3 ), are separated and studied

  18. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  19. 49 CFR 192.461 - External corrosion control: Protective coating.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Protective coating... for Corrosion Control § 192.461 External corrosion control: Protective coating. (a) Each external protective coating, whether conductive or insulating, applied for the purpose of external corrosion control...

  20. Template-guided interstitial implants: Cs-137 reusable sources as a substitute for Ir-192

    International Nuclear Information System (INIS)

    Williamson, J.F.; Seminoff, T.

    1987-01-01

    Template-guided implantation of rigid steel or plastic guide needles for afterloading of radioactive sources is widely used in the treatment of gynecologic, rectal, and urologic malignant neoplasms. Iridium-192 is used almost universally, despite the high cost per implant, due to its short half-life and limited need for a flexible, trimmable source. A reusable afterloading system containing cesium-137 was developed. Each source has an effective active length of 6.8 cm and is encapsulated at the distal end of a 21-cm-long stainless steel tube. The sources can be afterloaded into the same plastic guide needles normally used for Ir-192 ribbons. Physical and dosimetric aspects of these sources are compared with those of Ir-192, and radiation protection and cost effectiveness are also discussed

  1. A projector of iridium 192 wires: motivations and preliminary studies

    International Nuclear Information System (INIS)

    Cosset, J.M.; Gerbaulet, A.; Chassagne, D.

    1979-01-01

    Though the majority of procedures involved in curietherapy with Iridium 192 wires cause very few problems concerning radiation protection, this is not true in all cases: in elderly of debilitated patients, young children, or when using special techniques (curietherapy for prostate of bladder cancers for example). In these cases, the need for frequent treatment exposes the therapists to increased doses. The projector of Iridium 192 wires was conceived in order to reduce this irradiated hazard. A simple manipulation places the radioactive wires in a lead container during treatment, and then replaces them in the right position after therapy. This apparatus appears to offer the possibility of: an almost total protection of the therapists, and thus an opportunity for enlarging the indications for curietherapy; an improved quality of treatment to the patient during the application [fr

  2. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  3. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  4. 49 CFR 192.111 - Design factor (F) for steel pipe.

    Science.gov (United States)

    2010-10-01

    ... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Pipe Design § 192.111 Design factor (F... street, or a railroad; (3) Is supported by a vehicular, pedestrian, railroad, or pipeline bridge; or (4...

  5. 49 CFR Appendix B to Part 192 - Qualification of Pipe

    Science.gov (United States)

    2010-10-01

    ..., “Standard Specification for Carbon and Alloy Steel Pipe, Electric-Fusion-Welded for High Pressure Service at... by reference, see § 192.7). ASTM D2517—Thermosetting plastic pipe and tubing, “Standard Specification...

  6. Design criteria for rhenium-reduced nickel-based single-crystal alloys. Identification and computer-assisted conversion; Designkriterien fuer rheniumreduzierte Nickelbasis-Einkristalllegierungen. Identifikation und rechnergestuetzte Umsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Goehler, Thomas

    2016-06-17

    In the present work, design criteria and property models for the creep strength optimization of rhenium-free nickel based single crystal Superalloys are investigated. The study focuses on a typical load condition of 1050 C and 150 MPa, which is representative for flight engine applications. Thereby the key aspect is to link chemical composition, manufacturing processes, microstructure formation and mechanistic understanding of dislocation creep through a computational materials engineering approach. Beside the positive effect of rhenium on solid solution hardening, a second mechanism in which rhenium increases high temperature creep strength is identified. It indirectly stabilizes precipitation hardening by reducing the coarsening kinetics of γ'-rafting. Five 1st and 2nd generation technical Superalloys show a comparable microstructure evolution for up to 2 % plastic elongation, while creep times differ by a factor of five. The application of a microstructure sensitive creep model shows that these coarsening processes can activate γ-cutting and thus lead to an increasing creep rate. Based on these calculations a threshold value of φ{sub γ/γ'} > 2,5 at 150 MPa is estimated. This ratio of matrix channel to raft thickness has been proofed for multiple positions by microstructure analysis of interrupted creep tests. The mechanism described previously can be decelerated by the enrichment of the γ-matrix with slow diffusing elements. The same principle also increases the solid solution strength of the γ-matrix. Therefore, the present work delivers an additional mechanistic explanation why creep properties of single phase nickel based alloys can be transferred to two phase technical Superalloys with rafted γ'-structure. Following, the best way to substitute both rhenium fundamental properties, namely a slow diffusion coefficient and a small solubility in g', has been investigated by means of CALPHAD-modeling. Only molybdenum and especially

  7. Thermal decomposition of rhenium (5) complexes with 1,2,4-triazole. Termicheskoe razlozhenie kompleksov reniya (5) s 1,2,4-triazolom

    Energy Technology Data Exchange (ETDEWEB)

    Amindzhanov, A A; Gagieva, S Ch; Kotegov, K V [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1991-01-01

    Processes of thermal decomposition of rhenium (5) complexes with 1,2,4-triazole were studied. Thermolysis products were identified on the basis of data of the element analysis, IR spectra, conductometry and other methods. It is ascertained that at the first stage of thermolysis of hydroxyl-containing monomer complexes removal of water molecules occurs, and at the second one - dimerization process with formation of Re-O-Re group. It is shown that the nature of halide ion practically does not affect the temperature of the start of intensive thermal decomposition of the complexes.

  8. 49 CFR 192.939 - What are the required reassessment intervals?

    Science.gov (United States)

    2010-10-01

    ....939 Section 192.939 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas...

  9. 49 CFR 192.947 - What records must an operator keep?

    Science.gov (United States)

    2010-10-01

    ... Section 192.947 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline...

  10. 49 CFR 192.949 - How does an operator notify PHMSA?

    Science.gov (United States)

    2010-10-01

    ... 192.949 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity...

  11. 49 CFR 192.1011 - What records must an operator keep?

    Science.gov (United States)

    2010-10-01

    ... Section 192.1011 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline...

  12. 49 CFR 192.487 - Remedial measures: Distribution lines other than cast iron or ductile iron lines.

    Science.gov (United States)

    2010-10-01

    ... cast iron or ductile iron lines. 192.487 Section 192.487 Transportation Other Regulations Relating to... iron or ductile iron lines. (a) General corrosion. Except for cast iron or ductile iron pipe, each... the purpose of this paragraph. (b) Localized corrosion pitting. Except for cast iron or ductile iron...

  13. 41 CFR 102-192.150 - What are your general responsibilities as a program level mail manager?

    Science.gov (United States)

    2010-07-01

    ... responsibilities as a program level mail manager? 102-192.150 Section 102-192.150 Public Contracts and Property... general responsibilities as a program level mail manager? Your responsibilities at the program level include— (a) Working closely with the agency mail manager and mail center managers who handle significant...

  14. 27 CFR 479.192 - Commerce in firearms and ammunition.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Commerce in firearms and..., AND CERTAIN OTHER FIREARMS Other Laws Applicable § 479.192 Commerce in firearms and ammunition. For provisions relating to commerce in firearms and ammunition, including the movement of destructive devices...

  15. Comparison of 60Cobalt and 192Iridium sources in high dose rate afterloading brachytherapy

    International Nuclear Information System (INIS)

    Richter, J.; Baier, K.; Flentje, M.

    2008-01-01

    Purpose: 60 Co sources with dimensions identical to those of 192 Ir have recently been made available in clinical brachytherapy. A longer half time reduces demands on logistics and quality assurance and perhaps costs. Material and Methods: Comparison of the physical properties of 60 Co and 192 Ir with regard to brachytherapy. Results: Required activities for the same air kerma rate are lower by a factor of 2.8 for 60 Co. Differential absorption in tissues of different densities can be neglected. Monte Carlo calculations demonstrate that integral dose due to radial dose fall off is higher for 192 Ir in comparison to 60 Co within the first 22 cm from the source (normalization at 1 cm). At larger distances this relationship is reversed. Conclusion: Clinical examples for intracavitary and interstitial applications however, show practically identical dose distributions in the treatment volume. (orig.)

  16. CYP2C19*2 status in patients with Stevens-Johnson syndrome and toxic epidermal necrolysis

    Directory of Open Access Journals (Sweden)

    Laska AJ

    2017-05-01

    Full Text Available Amanda J Laska,1 Marie J Han,1 Josh A Lospinoso,2 Patrick J Brown,1 Thomas M Beachkofsky1 1Department of Dermatology, San Antonio Uniformed Services Health Education Consortium, San Antonio, TX, 2780th Military Intelligence Brigade, Ft Meade, MD, USA Purpose: Genetic polymorphisms have been linked to an increased predisposition to developing certain diseases. For example, patients of Han-Chinese descent carrying the HLA-B*1502 allele are at an increased risk of developing Stevens-Johnson syndrome and toxic epidermal necrolysis (SJS/TEN if given carbamazepine. Given the complexity of in vivo drug metabolism, it is plausible that the activity of enzyme systems unrelated to specific drug metabolism may be important. Although multiple biomarkers have been identified in unique ethnic groups, there has yet to be a study investigating the presence of the slow metabolizing allele of CYP2C19, denoted CYP2C19*2, in diverse groups and the risk of developing SJS/TEN. Patients and methods: This study looked into the carrier status of CYP2C19*2, a poor metabolizing variant of CYP2C19, in patients diagnosed with SJS/TEN. We looked at its status in our series as a whole and when patients were divided by ethnicity. Genomic DNA was extracted from formalin-fixed paraffin-embedded tissue of patients with biopsy-proven SJS/TEN and real-time polymerase chain reaction was used to assess for the presence of CYP2C19*2. Results: CYP2C19*2 status was determined in 47 patients. Twenty-nine of these 47 patients had a single medication implicated as causing their disease, and eight of these patients were heterozygous or homozygous for CYP2C19*2. There was insufficient evidence to conclude that the presence of CYP2C19*2 is an independent predictor of risk for developing SJS/TEN in our series as a whole. This analysis also confirmed that the frequency of the CYP2C19*2 polymorphism within the different ethnicities in our series did not vary statistically from reported ethnic

  17. 49 CFR 192.241 - Inspection and test of welds.

    Science.gov (United States)

    2010-10-01

    ... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.241 Inspection and test of welds. (a) Visual inspection of welding must be conducted by an individual qualified by appropriate training and experience to ensure that: (1) The welding is performed in accordance...

  18. Laser-induced breakdown spectroscopy measurement of a small fraction of rhenium in bulk tungsten

    Science.gov (United States)

    Nishijima, D.; Ueda, Y.; Doerner, R. P.; Baldwin, M. J.; Ibano, K.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) of bulk rhenium (Re) and tungsten (W)-Re alloy has been performed using a Q-switched Nd:YAG laser (wavelength = 1064 nm, pulse width ∼4-6 ns, laser energy = 115 mJ). It is found that the electron temperature, Te, of laser-induced Re plasma is lower than that of W plasma, and that Te of W-Re plasma is in between Re and W plasmas. This indicates that material properties affect Te in a laser-induced plasma. For analysis of W-3.3%Re alloy, only the strongest visible Re I 488.9 nm line is found to be used because of the strong enough intensity without contamination with W lines. Using the calibration-free LIBS method, the atomic fraction of Re, cRe, is evaluated as a function of the ambient Ar gas pressure, PAr. At PAr 10 Torr due to spectral overlapping of the Re I 488.9 nm line by an Ar II 488.9 nm line.

  19. Prototype commercial electrooxidation cell for the recovery of molybdenum and rhenium from molybdenite concentrates

    International Nuclear Information System (INIS)

    Scheiner, B.J.; Pool, D.L.; Lindstrom, R.E.; McCleland, G.E.

    1979-01-01

    As part of the goal to maximize minerals and metals recovery from primary domestic resources, design factors associated with minimizing current leakage in bipolar cell configurations were studied as a means of improving the efficiency of bipolar electrooxidation cells. Initial studies that were conducted in a small bipolar cell operating at 140 to 145 volts and 15.4 A indicated how design factors could be employed to minimize current leakage around adjacent electrodes during cell operation. Based on these results, a 40-electrode, 108-kVA prototype of an industrial-sized cell was constructed and tested for extracting metal values from offgrade molybdenite concentrates. The feasibility of recovering molybdenum and rhenium from the oxidized pulp also was determined. Feed to the process sequence consisted of flotation concentrates containing 16 to 35% Mo as molybdenite and 6 to 15% Cu. Electrooxidation in the prototype cell results in 84 to 97% Mo and Re extraction with a corresponding energy consumption of 9 to 13 kWh/lb Mo extracted

  20. Anomalous second ferromagnetic phase transition in Co{sub 0.08}Bi{sub 1.92}Se{sub 3} topological insulator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Min, E-mail: zmzmi1987@163.com; Liu, Ligang; Yang, Hui

    2016-09-05

    We report the observation of ferromagnetism in topological insulator Co{sub 0.08}Bi{sub 1.92}Se{sub 3} single crystal. The structural, magnetic, and microstructure properties of Co{sub 0.08}Bi{sub 1.92}Se{sub 3} are investigated. The existence of complicated ferromagnetic ordering, indicates the anomalous second ferromagnetic phase transition below 30 K. Well-defined ferromagnetic hysteresis in the magnetization was found in the sample. The origin of bulk ferromagnetism in Co{sub 0.08}Bi{sub 1.92}Se{sub 3} is concerned with three aspects: Co cluster, RKKY interactions, and the spin texture of Co impurities. - Highlights: • The bulk ferromagnetism have been found in the C{sub o0.08}Bi{sub 1.92}Se{sub 3} single crystal. • The anomalous second ferromagnetic phase transition is found below 30 K. • The origin of bulk ferromagnetism in Co{sub 0.08}Bi{sub 1.92}Se{sub 3} is concerned with three aspects.

  1. Influence of paraoxonase-1 Q192R and cytochrome P450 2C19 polymorphisms on clopidogrel response

    Directory of Open Access Journals (Sweden)

    Li L

    2012-02-01

    Full Text Available Rolf P Kreutz1,2, Perry Nystrom2, Yvonne Kreutz2, Jia Miao2, Zeruesenay Desta2, Jeffrey A Breall1, Lang Li2, ChienWei Chiang2, Richard Kovacs1, David A Flockhart2, Yan Jin21Krannert Institute of Cardiology, 2Division of Clinical Pharmacology, Indiana University School of Medicine, Indianapolis, IN, USABackground: The metabolic activation of clopidogrel is a two-step process. It has been suggested that paraoxonase-1 (PON1 is a rate-limiting enzyme in the conversion of 2-oxo-clopidogrel to an active thiol metabolite. Conflicting results have been reported in regard to (1 the association of a common polymorphism of PON1 (Q192R with reduced rates of coronary stent thrombosis in patients taking clopidogrel and (2 its effects on platelet inhibition in patient populations of European descent. Methods: Blood samples from 151 subjects of mixed racial background with established coronary artery disease and who received clopidogrel were analyzed. Platelet aggregation was determined with light transmittance aggregometry and VerifyNow® P2Y12 assay. Genotyping for cytochrome P450 2C19 (CYP2C19*2 and *3 and PON1 (Q192R polymorphisms was performed.Results: Carriers of CYP2C19*2 alleles exhibited lower levels of platelet inhibition and higher on-treatment platelet aggregation than noncarriers. There was no significant difference in platelet aggregation among PON1 Q192R genotypes. Homozygous carriers of the wild-type variant of PON1 (QQ192 had similar on-treatment platelet reactivity to carriers of increased-function variant alleles during maintenance clopidogrel dosing, as well as after administration of a clopidogrel 600 mg loading dose.Conclusion: CYP2C19*2 allele is associated with impaired platelet inhibition by clopidogrel and high on-treatment platelet aggregation. PON1 (Q192R polymorphism does not appear to be a significant determinant of clopidogrel response.Keywords: PON1, platelet, aggregation, cytochrome P450 enzymes

  2. Comparison of radiation shielding requirements for HDR brachytherapy using 169Yb and 192Ir sources

    International Nuclear Information System (INIS)

    Lymperopoulou, G.; Papagiannis, P.; Sakelliou, L.; Georgiou, E.; Hourdakis, C. J.; Baltas, D.

    2006-01-01

    169 Yb has received a renewed focus lately as an alternative to 192 Ir sources for high dose rate (HDR) brachytherapy. Following the results of a recent work by our group which proved 169 Yb to be a good candidate for HDR prostate brachytherapy, this work seeks to quantify the radiation shielding requirements for 169 Yb HDR brachytherapy applications in comparison to the corresponding requirements for the current 192 Ir HDR brachytherapy standard. Monte Carlo simulation (MC) is used to obtain 169 Yb and 192 Ir broad beam transmission data through lead and concrete. Results are fitted to an analytical equation which can be used to readily calculate the barrier thickness required to achieve a given dose rate reduction. Shielding requirements for a HDR brachytherapy treatment room facility are presented as a function of distance, occupancy, dose limit, and facility workload, using analytical calculations for both 169 Yb and 192 Ir HDR sources. The barrier thickness required for 169 Yb is lower than that for 192 Ir by a factor of 4-5 for lead and 1.5-2 for concrete. Regarding 169 Yb HDR brachytherapy applications, the lead shielding requirements do not exceed 15 mm, even in highly conservative case scenarios. This allows for the construction of a lead door in most cases, thus avoiding the construction of a space consuming, specially designed maze. The effects of source structure, attenuation by the patient, and scatter conditions within an actual treatment room on the above-noted findings are also discussed using corresponding MC simulation results

  3. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Science.gov (United States)

    2010-10-01

    ... pipe before it is installed. (b) Testing of repairs made by welding. Each repair made by welding in... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line is...

  4. Superdeformation studies in the odd-odd nucleus {sup 192}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S.; Carpenter, M.P.; Janssens, R.V.F. [and others

    1995-08-01

    The study of yrast and near-yrast structures of odd-odd nuclei to high spins is somewhat limited due to the complexity of the spectra resulting from the many proton-neutron couplings near the Fermi surface. In superdeformed nuclei, the number of available protons and neutrons near the Fermi surface is somewhat limited due to the presence of large-shell gaps which stabilize the nuclear shape. A relatively small number of available neutron and proton configurations can lead to fragmentation of the SD intensity into a number of different bands. Two good examples of this phenomenon were found in {sup 192}Tl and {sup 194}Tl where the presence of six superdeformed bands were reported in both nuclei. We reexamined {sup 192}Tl at Gammasphere using the {sup 160}Gd({sup 37}Cl,5n) reaction at 178 MeV to populate states in the superdeformed well of this nucleus. While our previous study on {sup 192}Tl at ATLAS was very successful, a number of questions remained which formed the basis of our objectives in this experiment: obtain better {gamma}-ray energies for the known transitions and identify higher spin members in each band; determine how the bands feed the known yrast states in {sup 192}Tl as well as determine the complete spectrum in coincidence with the SD bands; look for M1 transitions connecting proposed signature partners; and attempt to identify other excitations in the superdeformed well. Analysis is underway and four of the six bands were confirmed. The reasons that two of the reported bands were not observed in this latest work is still under investigation. As of this time, no other superdeformed bands were identified in the data. Two of the confirmed SD bands have a constant moment of inertia and show indications of cross-talk between each other. This observation is not unexpected since the calculated M1 rates for the proposed configuration of the band, {pi}{sub 13/2} x {upsilon}j{sub 15/2}, indicate that M1 transitions linking the two SD bands should be observed.

  5. SPS Fabrication of Tungsten-Rhenium Alloys in Support of NTR Fuels Development

    International Nuclear Information System (INIS)

    Webb, Jonathan A.; Charit, Indrajit; Sparks, Cory; Butt, Darryl P.; Frary, Megan; Carroll, Mark

    2011-01-01

    Tungsten metal slugs were fabricated via Spark Plasma Sintering (SPS) of powdered metals at temperatures ranging from 1575 K to 1975 K and hold times of 5 minutes to 30 minutes, using powders with an average diameter of 7.8 ?m. Sintered tungsten specimens were found to have relative densities ranging from 83 % to 94 % of the theoretical density for tungsten. Consolidated specimens were also tested for their Vickers Hardness Number (VHN), which was fitted as a function of relative density; the fully consolidated VHN was extrapolated to be 381.45 kg/mm2. Concurrently, tungsten and rhenium powders with average respective diameters of 0.5 ?m and 13.3 ?m were pre-processed either by High-Energy-Ball-Milling (HEBM) or by homogeneous mixing to yield W-25at.%Re mixtures. The powder batches were sintered at temperatures of 1975 K and 2175 K for hold times ranging from 0 minutes to 60 minutes yielding relative densities ranging from 94% to 97%. The combination of HEBM and sintering showed a significant decrease in the inter-metallic phases compared to that of the homogenous mixing and sintering.

  6. Rhenium 188 labelling of peptide conjugates

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura

    2001-01-01

    Many human tumours express high levels, of somatostatin receptors. In order to make possible a radiotherapeutic treatment of this kind for tumour a series of somatostatin analogues that can tightly chelate beta emitting isotopes have been developed in recent years. The work carried out for this thesis has been aimed towards development of a new therapeutic radiopharmaceutical for treatment of somatostatin receptor positive tumours. The first chapters describe work with technetium-99m to establish the labelling and analytical conditions for a somatostatin analogue, [Tyr 3 ]-octreotide (TOC), as a precursor to undertaking labelling studies with the beta emitter rhenium-188. 6-Hydrazinopyridine-3-carboxylic acid (HYNIC) was conjugated to TOC and labelled with 99m using different coligands. Then the stability, receptor binding and biodistribution of each complex were assessed. 99m Tc-HYNIC-TOC using EDDA as coligand showed the best characteristics, and was superior for tumour imaging in humans than the commercially available 111 In-DTPA-octreotide. The conditions for labelling the HYNIC-TOC conjugate with 188 Re were then optimised using tricine as a co-ligand. A labelling yield of ∼80% was achieved. After purification however, the stability of the complex was low. The use of other coligand systems which had proved useful for 99m Tc labelling was explored, but yields were very poor. Other chelators such as diethylenetriamine pentaacetic acid (DTPA), dimercaptosuccinic acid (DMSA) and mercaptoacetyltriglycine (MAG 3 ) were studied as potential co-ligand agents to label the HYNIC-TOC conjugate with 188 Re but, again low yields of the labelled peptide complexes were achieved. A novel 188 Re-HYNIC complex was prepared in high yields using N-N-disubstituted dithiocarbamates as coligands. However to date, the specific activities achieved with this system are relatively low. The use of the [ 99m Tc(CO) 3 (H 2 O) 3 ] complex to label the HYNIC-TOC conjugate was investigated

  7. The Expression of miR-192 and Its Significance in Diabetic Nephropathy Patients with Different Urine Albumin Creatinine Ratio

    Directory of Open Access Journals (Sweden)

    Xiaoyu Ma

    2016-01-01

    Full Text Available Objective. To investigate the expression of miR-192 and its significance in diabetic nephropathy (DN patients. Methods. 464 patients with type 2 diabetes mellitus (T2DM were divided into normal albuminuria group (NA, n=157, microalbuminuria group (MA, n=159, and large amount of albuminuria group (LA, n=148. 127 healthy persons were selected as the control group (NC, n=127. The serum miR-192 levels were detected by Real-Time PCR and transforming growth factor-β1 (TGF-β1 and fibronectin (FN were detected by enzyme-linked immunosorbent assay. The relationships among these parameters were analyzed by Pearson correlation analysis and multiple linear regression analysis. Results. The miR-192 in the LA group was significantly lower than other groups, which was lower in the MA group than in the NA group (P<0.01. The TGF-β1 and FN in the LA group were significantly higher than other groups, which were higher in the MA group than in the NA group (P<0.01. The expression of miR-192 was negatively correlated with TGF-β1, FN, and Ln (UACR and miR-192, TGF-β1, and FN were independent relevant factors affecting Ln (UACR in T2DM (P<0.01. Conclusions. These findings indicate that the levels of miR-192 were lower accompanied by the decrease of urine albumin creatinine ratio (UACR and the association between miR-192 and nephritic fibrosis in DN.

  8. 49 CFR 192.123 - Design limitations for plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Design limitations for plastic pipe. 192.123... Design limitations for plastic pipe. (a) Except as provided in paragraph (e) and paragraph (f) of this section, the design pressure may not exceed a gauge pressure of 100 psig (689 kPa) for plastic pipe used...

  9. Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

    International Nuclear Information System (INIS)

    Gay, H A; Allison, R R; Downie, G H; Mota, H C; Austerlitz, C; Jenkins, T; Sibata, C H

    2007-01-01

    A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed

  10. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  11. High-spin states in the 192Pb and 193Pb isotopes

    International Nuclear Information System (INIS)

    Lagrange, J.M.; Pautrat, M.

    1991-01-01

    The 193 Pb and 192 Pb isotopes are produced through the 182 W( 16 O, 5n, 6n) reactions. The de-excitation γ-ray and conversion electron spectra lead to the conversion coefficients for most transitions. With the results of the γ-γ and e - -γ coincidences, the half-lives measured for several states, the angular distribution coefficients for the odd isotope and the transition multipolarities, the data on the 192 Pb level scheme has been much enhanced and the 193 Pb one studied for the first time. The experimental schemes are compared to those given by microscopic calculations, in a two or three quasi-particle approximation using a surface delta interaction with a reduced pairing component. The discrepancies between theory and experiment are attributed to the increasing influence of proton configurations

  12. The dose distribution surrounding 192Ir and 137Cs seed sources

    International Nuclear Information System (INIS)

    Thomason, C.; Mackie, T.R.; Wisconsin Univ., Madison, WI; Lindstrom, M.J.; Higgins, P.D.

    1991-01-01

    Dose distributions in water were measured using LiF thermoluminescent dosemeters for 192 Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. Dose distribution was measured for a 137 Cs seed source. In addition, dose distributions surrounding these sources were calculated using the EGS4 Monte Carlo code and were compared to measured data. The two methods are in good agreement for all three sources. Tables are given describing dose distribution surrounding each source as a function of distance and angle. Specific dose constants were also determined from results of Monte Carlo simulation. This work confirms the use of the EGS4 Monte Carlo code in modelling 192 Ir and 137 Cs seed sources to obtain brachytherapy dose distributions. (author)

  13. Phase stability, physical properties of rhenium diboride under high pressure and the effect of metallic bonding on its hardness

    International Nuclear Information System (INIS)

    Zhong, Ming-Min; Kuang, Xiao-Yu; Wang, Zhen-Hua; Shao, Peng; Ding, Li-Ping; Huang, Xiao-Fen

    2013-01-01

    Highlights: •The transition pressure P t between the ReB 2 –ReB 2 and MoB 2 –ReB 2 phases is firstly determinate. •The single-bonded B–B feather remains in ReB 2 compounds. •A semiempirical method to evaluate the hardness of crystals with partial metallic bond is presented. •The large hardness (39.1 GPa) of ReB 2 –ReB 2 indicate that it is a superhard material. •The zigzag interconnected B–Re and B–B covalent bonds underlie the ultraincompressibilities. -- Abstract: Using first-principles calculations, the elastic constants, thermodynamic property and structural phase transition of rhenium diboride under pressure are investigated by means of the pseudopotential plane-waves method, as well as the effect of metallic bond on its hardness. Eight candidate structures of known transition-metal compounds are chosen to probe for rhenium diboride ReB 2 . The calculated lattice parameters are consistent with the experimental and theoretical values. Based on the third order Birch–Murnaghan equation of states, the transition pressure P t between the ReB 2 –ReB 2 and MoB 2 –ReB 2 phases is firstly determinate. Elastic constants, shear modulus, Young’s modulus, Poisson’s ratio and Debye temperature are derived. The single-bonded B–B feather remains in ReB 2 compounds. Furthermore, according to Mulliken overlap population analysis, a semiempirical method to evaluate the hardness of multicomponent crystals with partial metallic bond is presented. Both strong covalency and a zigzag topology of interconnected bonds underlie the ultraincompressibilities. In addition, the superior performance and large hardness (39.1 GPa) of ReB 2 –ReB 2 indicate that it is a superhard material

  14. Computer dosimetry of 192Ir wire

    International Nuclear Information System (INIS)

    Kline, R.W.; Gillin, M.T.; Grimm, D.F.; Niroomand-Rad, A.

    1985-01-01

    The dosimetry of 192 Ir linear sources with a commercial treatment planning computer system has been evaluated. Reference dose rate data were selected from the literature and normalized in a manner consistent with our clinical and dosimetric terminology. The results of the computer calculations are compared to the reference data and good agreement is shown at distances within about 7 cm from a linear source. The methodology of translating source calibration in terms of exposure rate for use in the treatment planning computer is developed. This may be useful as a practical guideline for users of similar computer calculation programs for iridium as well as other sources

  15. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  16. Dosimetry experience of 192IR sources used In HDR brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Daci, Lulzime; Myrku, Rodina Cela

    2013-01-01

    Purpose/Objective: The 192IR Sources are the most commonly used in radiotherapy treatments HDR worldwide. According to international recommendations on quality assurance in HDR brachytherapy, an acceptance test based on the determination of the source strength of any new source shall be carried out before first application to verify the manufacturer’s calibration data. The present paper gives the experimental determination of the source strength for our brachytherapy sources used until now in brachytherapy treatments. Materials/Methods: At Mother Teresa University Hospital we have a cost-effective gynecological brachytherapy unit from Eckert & Ziegler BEBIG named GyneSource® that is a five channel HDR after loader equipped with an 192IR source. The software used is HDR plus™ 2.5 that delivers an optimized treatment plan and makes the process especially fast and we use intracavitary BEBIG applicators. From April 2009 up to December 2012, we have imported nine HDR 192IR Sources. The exchange of the source and acceptance test is done by the physicist of the clinic once the source is imported. The measurements are done with a Well-type ionization chamber HDR1000 Plus and the electrometer used is MAX4000. Only seven sources are compared as we miss the dosimetry data of the first source, and the forth source was not measured and not used because the machine was not working in that time. Results/Conclusions: Eight sources were accepted for clinically use as the measurement were within the tolerance. The source number four with e deviation of -1.92% has been double checked compared with a free in-air measurement with farmer type chamber that gave a deviation to source certificate of 4% that is still inside the tolerance to accept a source for clinical use. The deviations of measured Air Kerma rate to the value of the sources certificates of all our used 192IR sources are less than 2%, which are within the tolerance. The checked value of updated source strength in

  17. Development of an Iridium-192 seed for use in ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos; Moura, Joao A.; Costa, Osvaldo L.; Feher, Anselmo; Moura, Eduardo S.; Souza, Carla D.; Peleias Junior, Fernando S.

    2011-01-01

    The Institute for Energy and Nuclear Research (IPEN), in partnership with the School or Medicine (UNIFESP), created a project that aims to develop and implement an ophthalmic therapeutic treatment for cancer with Iridium-192 seeds. The School of Medicine treats many cancer cases in the SUS (Brazilian Public Health System), and brachytherapy group of IPEN has extensive experience in prototype sources. The seed to be manufactured will perform as follows: a core of Iridium-192 is packaged inside small cylindrical seeds consist of a titanium capsule of 0.8 mm outer diameter, 0.05 mm wall thickness and 4 5 mm in length. The core is an alloy of platinum-iridium (20/80) of 3.0 mm in length and 0.3 mm in diameter. Material analysis, neutron activation and activity measurements were carried out. (author)

  18. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    Science.gov (United States)

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  19. Study and development of an Iridium-192 seed for use in ophthalmic cancer; Estudo e desenvolvimento de uma semente de iridio-192 para aplicacao em cancer oftalmico

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio Rodrigues de

    2013-07-01

    Even ocular tumors are not among the cases with a higher incidence, they affect the population, especially children. The Institute of Energy and Nuclear Research (IPEN-CNEN/SP) in partnership with Escola Paulista de Medicina (UNIFESP), created a project to develop and implement a alternative treatment for ophthalmic cancer that use brachytherapy iridium-192 seeds. The project arose by reason of the Escola Paulista treat many cancer cases within the Unified Health System (SUS) and the research experience of sealed radioactive sources group at IPEN. The methodology was developed from the available infrastructure and the experience of researchers. The prototype seed presents with a core (192-iridium alloy of iridium-platinum) of 3.0 mm long sealed by a capsule of titanium of 0.8 mm outside diameter, 0.05 mm wall thickness and 4,5mm long. This work aims to study and develop a seed of iridium-192 from a platinum-iridium alloy. No study on the fabrication of these seeds was found in available literature. It was created a methodology that involved: characterization of the material used in the core, creation of device for neutron activation irradiation and and seed sealing tests. As a result, proved the feasibility of the method. As a suggestion for future work, studies regarding metrology and dosimetry of these sources and improvement of the methodology should be carried out, for future implementation in national scope. (author)

  20. Extrahepatic bile duct carcinoma treated by intraluminal irradiation with iridium-192 wire

    International Nuclear Information System (INIS)

    Ikeda, Hiro; Kuroda, Tomosumi; Uchida, Hideo

    1980-01-01

    A 57-year-old male with obstructive jaundice was diagnosed extrahepatic bile duct carcinoma at bifurcation by percutaneous transhepatic cholangiography (PTC). He was treated 3,300 rad of external irradiation and then intraluminal irradiation using the Iridium-192 wire by two times with the aid of PTC internal drainage, each was given by the dose of 1,600 rad at 5 mm inside the tumor from the PTC-tube. He had been well for about 1 year and then died because of ascites and cachexia. Autopsy revealed only microscopic tumor cells remaining around the common duct below the cystic junction. It was confirmed that intraluminal irradiation using the Iridium-192 wire was potentially curable and easily applicable to the bile duct carcinoma. (author)

  1. Dose determination in breast tumor in brachytherapy using Iridium-192

    International Nuclear Information System (INIS)

    Okuno, S.F.

    1984-01-01

    Thermoluminescent dosimetry studies in vivo and in vitro aiming to determing radiation dose in the breast tumor, in brachytherapy using Iridium-192 was done. The correlation between radiation doses in tumor and external surface of the breast was investigated for correcting the time interval of radiation source implantation. (author) [pt

  2. 41 CFR 102-192.175 - What types of support does GSA offer to Federal agency mail management programs?

    Science.gov (United States)

    2010-07-01

    ... in mail management and mail operations; (b) Identifying better business practices and sharing them... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What types of support does GSA offer to Federal agency mail management programs? 102-192.175 Section 102-192.175 Public...

  3. 3.3.1. Synthesis, Spectroscopy and Structural Analysis of Technetium and Rhenium Nitrosyl Complexes

    Directory of Open Access Journals (Sweden)

    Terrence\tNicholson*,\tEsther\tChunb, Ashfaq\tMahmood,\tPeter\tMueller,\tAlan\tDavisona\tand\tAlun\tG.\tJones

    2015-11-01

    Full Text Available Here we report an overview of our synthetic, spectroscopic and structural studies of technetium and rhenium nitrosyl complexes. We review the results from various notes and short papers reported over the past 15 years and discuss their significance in terms of radiopharmaceutical design.A single new complex is reported, the ReI-NO complex [ReICl2(NO(py-N(Et-py], in which the tridentate ligand di-(2-picolyl(N-ethylamine, (py-N(Et-py, is coordinated in a meridional manner. This complex was synthesized from the reaction of the ReI-nitrosyl complex ReCl2(NO(NCMe3] and the neutral tri-amine ligand py-N(Et-py in methylene chloride under argon. The bright red species was isolated chromatographically and recrystallized from CH2Cl2/MeOH under diethylether.A review of literature values for nitrosyl complexes with various ligands bound to the coordination sitetrans- to the nitrosyl group shows only minor variations in the M-N-O bond angle.

  4. Differential Fault Analysis on CLEFIA with 128, 192, and 256-Bit Keys

    Science.gov (United States)

    Takahashi, Junko; Fukunaga, Toshinori

    This paper describes a differential fault analysis (DFA) attack against CLEFIA. The proposed attack can be applied to CLEFIA with all supported keys: 128, 192, and 256-bit keys. DFA is a type of side-channel attack. This attack enables the recovery of secret keys by injecting faults into a secure device during its computation of the cryptographic algorithm and comparing the correct ciphertext with the faulty one. CLEFIA is a 128-bit blockcipher with 128, 192, and 256-bit keys developed by the Sony Corporation in 2007. CLEFIA employs a generalized Feistel structure with four data lines. We developed a new attack method that uses this characteristic structure of the CLEFIA algorithm. On the basis of the proposed attack, only 2 pairs of correct and faulty ciphertexts are needed to retrieve the 128-bit key, and 10.78 pairs on average are needed to retrieve the 192 and 256-bit keys. The proposed attack is more efficient than any previously reported. In order to verify the proposed attack and estimate the calculation time to recover the secret key, we conducted an attack simulation using a PC. The simulation results show that we can obtain each secret key within three minutes on average. This result shows that we can obtain the entire key within a feasible computational time.

  5. Effect of source encapsulation on the energy spectra of sup 192 Ir and sup 137 Cs seed sources

    Energy Technology Data Exchange (ETDEWEB)

    Thomason, C [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics; Mackie, T R [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics Wisconsin Univ., Madison, WI (USA). Dept. of Human Oncology; Lindstrom, M J [Wisconsin Univ., Madison, WI (USA). Biostatistics Center

    1991-04-01

    The effect of source encapsulation on the energy spectra of {sup 192}Ir and {sup 137}Cs seed sources, both with stainless steel and with platinum encapsulation, was determined from results of Monte Carlo simulation. The fractional scatter dose around these sources has also been determined from Monte Carlo simulation. The platinum-encapsulated {sup 192}Ir source exhibited greater attenuation of the primary spectrum, as expected, and, consistent with this greater attenuation, exhibited more scattered radiation. Significantly less scatter was seen with the {sup 137}Cs source than with either {sup 192}Ir source, as is consistent with the higher-energy photons from {sup 137}Cs. (author).

  6. Application of rhenium 186 radiosynovectomy in elbow diffuse pigmented villonodular synovitis: Case report with multiple joint involvement

    International Nuclear Information System (INIS)

    Koca, Go Khan; Ozsoy, Ha Kan; Atilgan, Hasan Ikbal; Demirel, Koray; Dincel, Veysel Ercan; Korkmaz, Meliha

    2012-01-01

    After surgical therapy of diffuse pigmented villonodular synovitis (DPVNS), recurrence is seen in almost half of the patients. The effectiveness of radiosynovectomy (RSV)in preventing recurrence and complaints of DPVNS is well known. Elbow involvement in DPVNS is a very rare condition; therefore, RSV in elbow hasn't been experienced widely. The aim of this case report is to show the effectiveness of RSV with rhenium 186 (Re 186)sulfide colloid. We applied Re 186 sulfide colloid to the elbow joint of DPVNS patients six weeks after arthroscopic synovectomy. As a result, the patient did not have any complaints, and our findings are compatible with residue or recurrence on magnetic resonance imaging (MRI)in sixth and twentieth month controls after administration. We concluded that Re 186 is an effective adjuvant therapy for the prevention of recurrence and complaints

  7. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  8. Dosimetric evaluation of a new OneDose MOSFET for Ir-192 energy

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Deshpande, Deepak D

    2006-01-01

    The purpose of this study was to investigate dosimetry (reproducibility, energy correction, relative response with distance from source, linearity with threshold dose, rate of fading, temperature and angular dependence) of a newly designed OneDose TM MOSFET patient dosimetry system for use in HDR brachytherapy with Ir-192 energy. All measurements were performed with a MicroSelectron HDR unit and OneDose MOSFET detectors. All dosimeters were normalized to 3 min post-irradiation to minimize fading effects. All dosimeters gave reproducible readings with mean deviation of 1.8% (SD 0.4) and 2.4% (SD 0.6) for 0 0 and 180 0 incidences, respectively. The mean energy correction factor was found to be 1.1 (range 1.06-1.12). Overall, there was 60% and 40% mean response of the MOSFET at 2 and 3 cm, respectively, from the source. MOSFET results showed good agreement with TLD and parallel plate ion chamber. Linear dose response with threshold voltage shift was observed with applied doses of 0.3 Gy-5 Gy with Ir-192 energy. Linearity (R 2 = 1) was observed in the MOSFET signal with the applied dose range of 0.3 Gy-5 Gy with Ir-192 energy. Fading effects were less than 1% after 10 min and the MOSFET detectors stayed stable (within 5%) over a period of 1 month. The MOSFET response was found to be decreased by approximately 1.5% at 37 deg. C compared to 20 deg. C. The isotropic response of the MOSFET was found to be within ±6%. A maximum deviation of 5.5% was obtained between 0 deg. and 180 deg. for both the axes and this should be considered in clinical applications. The small size, cable-less, instant readout, permanent storage of dose and ease of use make the MOSFET a novel dosimeter and beneficial to patients for skin dose measurements with HDRBT using an Ir-192 source compared to the labour demanding and time-consuming TLDs

  9. Comparison of the hypothetical (57)Co brachytherapy source with the (192)Ir source.

    Science.gov (United States)

    Toossi, Mohammad Taghi Bahreyni; Ghorbani, Mahdi; Rostami, Atefeh; Khosroabadi, Mohsen; Khademi, Sara; Knaup, Courtney

    2016-01-01

    The (57)Co radioisotope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical (57)Co source. A hypothetical (57)Co source was simulated in MCNPX, consisting of an active cylinder with 3.5 mm length and 0.6 mm radius encapsulated in a stainless steel capsule. Three photon energies were utilized (136 keV [10.68%], 122 keV [85.60%], 14 keV [9.16%]) for the (57)Co source. Air kerma strength, dose rate constant, radial dose function, anisotropy function, and isodose curves for the source were calculated and compared to the corresponding data for a (192)Ir source. The results are presented as tables and figures. Air kerma strength per 1 mCi activity for the (57)Co source was 0.46 cGyh(-1) cm 2 mCi(-1). The dose rate constant for the (57)Co source was determined to be 1.215 cGyh(-1)U(-1). The radial dose function for the (57)Co source has an increasing trend due to multiple scattering of low energy photons. The anisotropy function for the (57)Co source at various distances from the source is more isotropic than the (192)Ir source. The (57)Co source has advantages over (192)Ir due to its lower energy photons, longer half-life, higher dose rate constant and more isotropic anisotropic function. However, the (192)Ir source has a higher initial air kerma strength and more uniform radial dose function. These properties make (57)Co a suitable source for use in brachytherapy applications.

  10. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident; Recuperacion de hojuelas de Iridio-192 provenientes de una fuente radiactivas de uso industrial despues de un incidente radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, W.H.; Zapata, L.A., E-mail: wcruz@ipen.gob.pe, E-mail: lzapata@ipen.gob.pe [Instituto Peruano de Energia Nuclear (GRRA/IPEN), Lima (Peru). Division de Gestion de Residuos Radiactivos

    2013-07-01

    The Iridium-192 ({sup 192}Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m{sup 2}, some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  11. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy; Preparacion y determinacion del kerma de fuentes de iridio-192 de baja tasa de dosis para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045-1, Salazar, Esrado de Mexico, D.F. (Mexico)

    2000-07-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 {+-} 0.531 M Bq and kerma in air 0.03200 {+-} 0.00006 m Gy m/h A. (Author)

  12. 41 CFR 102-192.65 - What features must our finance systems have to keep track of mail costs?

    Science.gov (United States)

    2010-07-01

    ... finance systems have to keep track of mail costs? 102-192.65 Section 102-192.65 Public Contracts and... What features must our finance systems have to keep track of mail costs? All agencies must have an... requirement, because the level at which it is cost-beneficial differs widely. The agency's finance system(s...

  13. 49 CFR 192.919 - What must be in the baseline assessment plan?

    Science.gov (United States)

    2010-10-01

    ....919 Section 192.919 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas...

  14. Rhenium (5) and molybdenum (5) complexes with 4',4''(5'')-ditretbutyldibenzo-24-crown-8. Kompleksnye soedineniya reniya (5) i molibdena (5) s 4',4''(5'')-ditretbutildibenzo-24-kraun-8

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G; Basitova, S M; Tashmukhamedova, A K; Sajfullina, N Zh [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (USSR)

    1989-10-01

    Rhenium and molybdenum complexes in +5 oxidation degree with 4',4''(5'')-ditretbutyldibenzo-24-crown-8 (L) are synthesized with 75-95 % yield. Composition and structure of compounds produced are investigated using element analysis, conductometry, IR spectroscopy, thermogravimetry methods. Oxidation degree of complexer metal is determined. It is ascertained that the compound composition corresponds to the MOLX{sub 3} formula, where M-Re, Mo; X-Cl{sup -}, Br{sup -}.

  15. 41 CFR 102-192.45 - How can we request a deviation from these requirements, and who can approve it?

    Science.gov (United States)

    2010-07-01

    ... and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Introduction to this Part § 102-192.45 How can we... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false How can we request a...

  16. 30 CFR 250.192 - What reports and statistics must I submit relating to a hurricane, earthquake, or other natural...

    Science.gov (United States)

    2010-07-01

    ... relating to a hurricane, earthquake, or other natural occurrence? 250.192 Section 250.192 Mineral Resources... statistics must I submit relating to a hurricane, earthquake, or other natural occurrence? (a) You must... tropical storm, or an earthquake. Statistics include facilities and rigs evacuated and the amount of...

  17. 41 CFR 102-192.35 - What definitions apply to this part?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT Introduction to this Part § 102-192.35 What definitions apply to this part? The following... responsible for mail policy implementation, operations, and financial management; the program level... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What definitions apply...

  18. Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir

    Directory of Open Access Journals (Sweden)

    Tarcísio Passos Ribeiro de Campos

    2016-04-01

    Full Text Available Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

  19. Decision model support of severity of injury traffic accident victims care by SAMU 192

    Directory of Open Access Journals (Sweden)

    Rackynelly Alves Sarmento Soares

    2013-01-01

    Full Text Available Traffic accidents produce high morbidity and mortality in several countries, including Brazil. The initial care to victims of accidents, by a specialized team, has tools for evaluating the severity of trauma, which guide the priorities. This study aimed to develop a decision model applied to pre-hospital care, using the Abbreviated Injury Scale, to define the severity of the injury caused by the AT, as well to describe the features of accidents and their victims, occurred in Joao Pessoa, Paraiba. This is a descriptive epidemiological investigation, sectional, which analyzed all victims of traffic accidents attended by the SAMU 192, João Pessoa-PB, in January, April and June 2010. Data were collected in the medical regulation sheets of SAMU 192. Most of victims were male (76%, aged between 20 and 39 years (60%. Most injuries were classified as AIS1 (62.5%. The model of decision support implemented was the decision tree that managed to correctly classify 95.98% of the severity of injuries. By this model, it was possible to extract 29 rules of gravity classification of injury, which may be used for decision-making teams of the SAMU 192.

  20. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq 192Ir source

    International Nuclear Information System (INIS)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A.

    1995-01-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate 192 Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq 192 Ir source for patients with gynaecological tumors

  1. Association of Paraoxonase-1 Q192R (rs662 Single Nucleotide Variation with Cardiovascular Risk in Coffee Harvesters of Central Colombia

    Directory of Open Access Journals (Sweden)

    Fernando Siller-López

    2017-01-01

    Full Text Available Paraoxonase 1 (PON1, a high-density lipoprotein-associated antioxidant enzyme, hydrolyzes several organophosphate pesticides and oxidized lipids. The PON1 Q192R polymorphism affects the catalytic efficiency and is considered a risk factor for pesticide intoxication and cardiovascular disease (CVD but the association is not consistent between individuals or populations. We aimed to study the association of PON1 Q192R polymorphism with CVD risk in coffee harvesters of central Colombia. Demographics were collected from 205 subjects via standardized questionnaires. Lipid profiles and serum butyrylcholinesterase (BChE were measured by standard procedures. The calculated 10-year atherosclerotic CVD (ASCVD risk was used as the cardiovascular risk estimate. Q192R genotype was determined by real-time PCR. Prevalence of hypertension, hypercholesterolemia, and the 10-year ASCVD risk was 33%, 62%, and 22%, respectively. BChE levels were no indicative of recent pesticide exposure, although a positive correlation was observed with BChE and hypercholesterolemia. The Q192R genotype frequencies were 38% (QQ, 44% (QR, and 18% (RR. We found an association of the 192Q genotype with hypertension. The results of this study signal the importance to evaluate the influence and potential interactions of BChE and PON1 192Q allele with known genetic and environmental factors implicated in the pathogenesis of CVD.

  2. Iridium-192 sources production for brachytherapy use

    International Nuclear Information System (INIS)

    Rostelato, Maria Elisa Chuery Martins

    1997-01-01

    The incidence of cancer increases every year in Brazil and turns out to be one of the most important causes of mortality. Some of the patients are treated with brachytherapy, a form of lesion treatment which is based on the insertion of sources into tumors, in this particular case, activated iridium wires. During this process, the ionizing radiation efficiently destroys the malignant cells. These iridium wires have a nucleus made out of an iridium-platinum alloy 20-30/70-80 of 0,1 mm in diameter either coated by platinum or encased in a platinum tube. The technique consists in irradiating the wire in the reactor neutron flux in order to produce iridium-192. The linear activity goes from 1 mCi/cm to 4 mCi/cm and the basic characteristic, which is required, is the homogeneity of the activation along the wire. It should not present a dispersion exceeding 5% on a wire measuring 50 cm in length, 0.5 mm or 0.3 mm in diameter. Several experiments were carried out in order to define the activation parameters. Wires from different origins were analyzed. It was concluded that United States of America and France wires were found to be perfectly adequate for brachytherapy purposes and have therefore been sent to specialized hospitals and successfully applied to cancer patients. Considering that the major purpose of this work is to make this product more accessible in Brazil, at a cost reflecting the Brazilian reality, the IPEN is promoting the preparation of iridium-192 sources to be used in brachytherapy, on a national level. (author)

  3. 49 CFR 192.931 - How may Confirmatory Direct Assessment (CDA) be used?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.931 How may Confirmatory Direct Assessment (CDA) be used? An...

  4. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident

    International Nuclear Information System (INIS)

    Cruz, W.H.; Zapata, L.A.

    2013-01-01

    The Iridium-192 ( 192 Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m 2 , some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  5. 49 CFR 192.285 - Plastic pipe: Qualifying persons to make joints.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Plastic pipe: Qualifying persons to make joints... Materials Other Than by Welding § 192.285 Plastic pipe: Qualifying persons to make joints. (a) No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure...

  6. The dose distribution surrounding sup 192 Ir and sup 137 Cs seed sources

    Energy Technology Data Exchange (ETDEWEB)

    Thomason, C [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics; Mackie, T R [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics Wisconsin Univ., Madison, WI (USA). Dept. of Human Oncology; Lindstrom, M J [Wisconsin Univ., Madison, WI (USA). Biostatistics Center; Higgins, P D [Cleveland Clinic Foundation, OH (USA). Dept. of Radiation Oncology

    1991-04-01

    Dose distributions in water were measured using LiF thermoluminescent dosemeters for {sup 192}Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. Dose distribution was measured for a {sup 137}Cs seed source. In addition, dose distributions surrounding these sources were calculated using the EGS4 Monte Carlo code and were compared to measured data. The two methods are in good agreement for all three sources. Tables are given describing dose distribution surrounding each source as a function of distance and angle. Specific dose constants were also determined from results of Monte Carlo simulation. This work confirms the use of the EGS4 Monte Carlo code in modelling {sup 192}Ir and {sup 137}Cs seed sources to obtain brachytherapy dose distributions. (author).

  7. PON1 L55M and Q192R gene polymorphisms and CAD risks in patients with hyperlipidemia : Clinical study of possible associations.

    Science.gov (United States)

    Chen, H; Ding, S; Zhou, M; Wu, X; Liu, X; Liu, J; Wu, Y; Liu, D

    2017-08-23

    A decreased plasma high density lipoprotein (HDL) cholesterol level is a strong risk factor for coronary artery disease (CAD). Antioxidant activity of HDL mainly lies in the activity of paraoxonase (PON). This study aimed to investigate the relationships between PON1 L55M and Q192R polymorphisms, and the risks of CAD in patients with hyperlipidemia. From January 2014 to January 2016, 244 patients were divided into hyperlipidemia, hyperlipidemia + CAD, and control groups. The hyperlipidemia and hyperlipidemia + CAD groups were designated as the case group. Serum PON1 concentrations were measured using the enzyme-linked immunosorbent assay. After isolating genomic DNA, the PON1 L55M and Q192R genes were amplified by polymerase chain reaction and sequenced. In the case group, the genotypes LM and LL were detected significantly more often than in the control group, as were the alleles R (33.33%, 42.12%) and L (22.78%, 29.11%). The frequency of QR and RR genotypes was significantly higher in the hyperlipidemia + CAD group than in the hyperlipidemia group; the allele R in the hyperlipidemia + CAD group (42.77%) was more frequent than in the hyperlipidemia group (23.78%). The Q192R polymorphism was associated with low serum PON1 concentrations, and the lowest concentration was observed in the 192QR + 192RR genotype (P = 0.03). Logistic regression analysis showed a significant correlation between the 192R allele and smoking (P = 0.03), body mass index (P = 0.02), systolic blood pressure (P = 0.004), total cholesterol (P = 0.03), triglycerides (P = 0.01), HDL (P = 0.004), and low density lipoprotein (P = 0.02). The PON1 alleles 192R and 55L are associated with CAD, and the Q192R polymorphism may be a risk factor for CAD.

  8. PON1Q192R genetic polymorphism modifies organophosphorous pesticide effects on semen quality and DNA integrity in agricultural workers from southern Mexico

    International Nuclear Information System (INIS)

    Perez-Herrera, N.; Polanco-Minaya, H.; Salazar-Arredondo, E.; Solis-Heredia, M.J.; Hernandez-Ochoa, I.; Rojas-Garcia, E.; Alvarado-Mejia, J.; Borja-Aburto, V.H.; Quintanilla-Vega, B.

    2008-01-01

    Pesticide exposure, including organophosphorous (OP) insecticides, has been associated with poor semen quality, and paraoxonase (PON1), an enzyme involved in OP deactivation, may have a role on their susceptibility, due to PON1 polymorphisms. Our objective was to evaluate the role of PON1Q192R polymorphism on the susceptibility to OP toxicity on semen quality and DNA integrity in agricultural workers. A cross-sectional study was conducted in farmers with Mayan ascendancy from southeastern Mexico chronically exposed to pesticides; mostly OP. Fifty four agricultural workers (18-55 years old) were included, who provided semen and blood samples. Semen quality was evaluated according to WHO, sperm DNA damage by in situ-nick translation (NT-positive cells), PON1Q192R polymorphism by real-time PCR and serum PON1 activity by using phenylacetate and paraoxon. Two OP exposure indexes were created: at the month of sampling and during 3 months before sampling, representing the exposure to spermatids-spermatozoa and to cells at one spermatogenic cycle, respectively. PON1 192R and 192Q allele frequencies were 0.54 and 0.46, respectively. Significant associations were found between OP exposure at the month of sampling and NT-positive cells and sperm viability in homozygote 192RR subjects, and dose-effect relationships were observed between OP exposure during 3 months before sampling and sperm quality parameters and NT-positive cells in homozygote 192RR farmers. This suggests that cells at all stages of spermatogenesis are target of OP, and that there exists an interaction between OP exposure and PON1Q192R polymorphism on these effects; farmers featuring the 192RR genotype were more susceptible to develop reproductive toxic effects by OP exposure

  9. Paraoxonase polymorphisms PON1 192 and 55 and longevity in Italian centenarians and Irish nonagenarians. A pooled analysis.

    Science.gov (United States)

    Rea, Irene M; McKeown, Pascal P; McMaster, Dorothy; Young, Ian S; Patterson, Chris; Savage, Maurice J; Belton, Christine; Marchegiani, Francesca; Olivieri, Fabiola; Bonafe, Massimiliano; Franceschi, Claudio

    2004-04-01

    PON1, an arylesterase, associated with high density lipoprotein (HDL), protects low density lipoprotein (LDL) against oxidative modification. Common polymorphisms PON1 55 (L/M) and 192 (Q/R) in the PON1 gene associate with atherosclerosis and heart disease. Because long-lived people seem protected from premature vascular death, we conducted a pooled statistical analysis to assess any association between these polymorphisms and longevity in a large combined group of Italian centenarians and octo/nonagenarians from Northern Ireland (NI). Separated DNA was available from 1479 subjects from Italy and Northern Ireland (NI). In Italy 308 centenarians (males 67, females 241, mean age 100.8, SD2.1 years) and 579 young controls (males 347, females 232, mean age 40.7, SD 12.7 years) were included in the study. In NI, 296 octo/nonagenarians (males 92, females 204, mean age 89.8, SD 5.7 years) and 296 young sex-matched subjects (mean age 13.0, SD 1.4 years) had available DNA. PON1 55 (L/M) and 192 (Q/R) polymorphisms were studied using a PCR-RFLP approach. There was a significant difference in PON1 192 genotypes in Italian centenarians compared to younger controls (X(2)= 6.8, df = 2 p= 0.03) and a similar but non significant trend between octo/nonagenarian and young subjects in NI (X(2) = 4.0, df=2, p=0.14). Using logistic regression analysis on the combined Italian and Irish datasets, there was a small survival advantage for centenarian and octo/nonagenarian subjects who were heterozygous for PON1 192 R allele, (OR 1.3, CI 1-1.6; p=0.04 with a stepwise increase for RR homozygous subjects (OR 1.7, CI 1.1-2.6; p = 0.02) compared to QQ subjects. Comparing R and Q alleles there was a survival advantage for octo/nonagenarian/centenarian subjects who carried the R allele (OR 1.3, CI 1.1-1.5; p = 0.007) but there was no sex-specific effect p =0.77) LL, LM and MM genotypes of PON 55 polymorphisms showed similar frequencies in Italy (39.9, 47.0, 13.1%) and Ireland (39.5, 48.6, 11

  10. Dissecting the Re-Os molybdenite geochronometer.

    Science.gov (United States)

    Barra, Fernando; Deditius, Artur; Reich, Martin; Kilburn, Matt R; Guagliardo, Paul; Roberts, Malcolm P

    2017-11-22

    Rhenium and osmium isotopes have been used for decades to date the formation of molybdenite (MoS 2 ), a common mineral in ore deposits and the world's main source of molybdenum and rhenium. Understanding the distribution of parent 187 Re and radiogenic daughter 187 Os isotopes in molybdenite is critical in interpreting isotopic measurements because it can compromise the accurate determination and interpretation of mineralization ages. In order to resolve the controls on the distribution of these elements, chemical and isotope mapping of MoS 2 grains from representative porphyry copper-molybdenum deposits were performed using electron microprobe and nano-scale secondary ion mass spectrometry. Our results show a heterogeneous distribution of 185,187 Re and 192 Os isotopes in MoS 2 , and that both 187 Re and 187 Os isotopes are not decoupled as previously thought. We conclude that Re and Os are structurally bound or present as nanoparticles in or next to molybdenite grains, recording a complex formation history and hindering the use of microbeam techniques for Re-Os molybdenite dating. Our study opens new avenues to explore the effects of isotope nuggeting in geochronometers.

  11. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  12. Thermal transformations of oxohalide complexes of rhenium(5) and molybdenum(5) with diazo-18-crown-6 in solid phase. Termicheskie prevrashcheniya oksogalogenidnykh kompleksov reniya(5) i molibdena(5) s diaza-18-kraun-6 v tverdoj faze

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1992-11-01

    Methods for synthesis and separation in solid state of the rhenium(5) and molybdenum(5) onium complexes with diaza-18-crown-6(L), the content of which according to the data of elementary analysis, IRS in the close and remote areas, thermogravimetry, conductometry and potentiometry corresponds to the (H[sub 2]L)[EOX[sub 5

  13. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq {sup 192}Ir source

    Energy Technology Data Exchange (ETDEWEB)

    Cuepers, S; Piessens, M; Verbeke, L; Roelstraete, A [Onze-Lieve-Vrouw Hospitaal, Aalst (Belgium). Dept. of Radiotherapy and Oncology

    1995-12-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate {sup 192}Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq {sup 192}Ir source for patients with gynaecological tumors.

  14. Shapes of the $^{192,190}$Pb ground states from beta decay studies using the total absorption technique

    CERN Document Server

    Estevez Aguado, M.E.; Agramunt, J.; Rubio, B.; Tain, J.L.; Jordan, D.; Fraile, L.M.; Gelletly, W.; Frank, A.; Csatlos, M.; Csige, L.; Dombradi, Zs.; Krasznahorkay, A.; Nacher, E.; Sarriguren, P.; Borge, M.J.G.; Briz, J.A.; Tengblad, O.; Molina, F.; Moreno, O.; Kowalska, M.; Fedosseev, V.N.; Marsh, B.A.; Fedorov, D.V.; Molkanov, P.L.; Andreyev, A.N.; Seliverstov, M.D.; Burkard, K.; Huller, W.

    2015-01-01

    The beta decay of $^{192,190}$Pb has been studied using the total absorption technique at the ISOLDE(CERN) facility. The beta-decay strength deduced from the measurements, combined with QRPA theoretical calculations, allow us to infer that the ground states of the $^{192,190}$Pb isotopes are spherical. These results represent the first application of the shape determination method using the total absorption technique for heavy nuclei and in a region where there is considerable interest in nuclear shapes and shape effects.

  15. Medium-spin levels and a 360 ns Isup(π)=19-/2 isomer in the N=80 nucleus 137La

    International Nuclear Information System (INIS)

    Kortelahti, M.; Pakkanen, A.; Piiparinen, M.; Komppa, T.; Komu, R.

    1981-03-01

    The level structure of 137 La has been studied using the 138 Ba(p,2n) reaction and methods of in-beam γ-ray and conversion-electron spectroscopy. The 137 La level scheme has been established with 21 new levels with spins up to (19/2) - . A 360 ns (19/2) - isomer at 1870 keV has been identified and a (πgsub(7/2)(νhsub(11/2)sup(-1)dsub(3/2)sup(-1)sub(7 - ))sub(19/2) - configuration is suggested for it. The level ordering of the πhsub(11/2)x2 + multiplet has been discussed on the basis of the triaxial rotor-plus-particle model which suggests a slightly oblate triaxial shape to the 137 La nucleus. (author)

  16. Recovery of Ir-192 sources during emergency situations

    International Nuclear Information System (INIS)

    Quadros, C.L.; Conceicao, M.A. da

    1988-01-01

    During operations for the carrying out of services through the utilization of Ir-192 radio sources in radiographic tests of equipment, emergency situations may occur due to various causes and which bring radiologic accidents with doses exceeding the maximum alloewd. This work has the purpose to submit and analyze the major types of radiological accidents and its consequences for the installations and the procedures for the recuperation of sources during such situations. Another aspect to be mentioned shall be the interruption of services - such as production - and which is to be the lowest possible during the emergency. (author) [pt

  17. Study and development of an Iridium-192 seed for use in ophthalmic cancer

    International Nuclear Information System (INIS)

    Mattos, Fabio Rodrigues de

    2013-01-01

    Even ocular tumors are not among the cases with a higher incidence, they affect the population, especially children. The Institute of Energy and Nuclear Research (IPEN-CNEN/SP) in partnership with Escola Paulista de Medicina (UNIFESP), created a project to develop and implement a alternative treatment for ophthalmic cancer that use brachytherapy iridium-192 seeds. The project arose by reason of the Escola Paulista treat many cancer cases within the Unified Health System (SUS) and the research experience of sealed radioactive sources group at IPEN. The methodology was developed from the available infrastructure and the experience of researchers. The prototype seed presents with a core (192-iridium alloy of iridium-platinum) of 3.0 mm long sealed by a capsule of titanium of 0.8 mm outside diameter, 0.05 mm wall thickness and 4,5mm long. This work aims to study and develop a seed of iridium-192 from a platinum-iridium alloy. No study on the fabrication of these seeds was found in available literature. It was created a methodology that involved: characterization of the material used in the core, creation of device for neutron activation irradiation and and seed sealing tests. As a result, proved the feasibility of the method. As a suggestion for future work, studies regarding metrology and dosimetry of these sources and improvement of the methodology should be carried out, for future implementation in national scope. (author)

  18. Radiolabeling and biotinylation of internalizing monoclonal antibody chimeric BR96: Potential use of extracorporeal immunoadsorption with enhanced tumor radioactivity retention of Iodine, Indium and Rhenium

    International Nuclear Information System (INIS)

    Chen, JianQing.

    1997-01-01

    In this thesis, methodology of radiolabeling and simultaneous biotinylation for internalizing monoclonal antibody chimeric BR96 have been investigated by using three element groups of potential therapeutic radionuclides iodine, indium and rhenium, and their different labeling methods. The biodistribution and kinetics of biotinylated and radiolabeled chiBR96 have been studied in colon carcinoma isografted rats. The potential use of ECIA, based on the biotin-avidin concept, has been evaluated and compared with the approach of avidin 'chase' in the same animal tumor model with respect to an enhancement of tumor-to-normal tissue (T/N) activity ratio. 131 refs

  19. Radiolabeling and biotinylation of internalizing monoclonal antibody chimeric BR96: Potential use of extracorporeal immunoadsorption with enhanced tumor radioactivity retention of Iodine, Indium and Rhenium

    Energy Technology Data Exchange (ETDEWEB)

    Chen, JianQing

    1997-01-01

    In this thesis, methodology of radiolabeling and simultaneous biotinylation for internalizing monoclonal antibody chimeric BR96 have been investigated by using three element groups of potential therapeutic radionuclides iodine, indium and rhenium, and their different labeling methods. The biodistribution and kinetics of biotinylated and radiolabeled chiBR96 have been studied in colon carcinoma isografted rats. The potential use of ECIA, based on the biotin-avidin concept, has been evaluated and compared with the approach of avidin `chase` in the same animal tumor model with respect to an enhancement of tumor-to-normal tissue (T/N) activity ratio. 131 refs.

  20. Iridium-192 implants in the treatment of tonsillar region malignancies

    International Nuclear Information System (INIS)

    Puthawala, A.A.; Syed, A.M.; Gates, T.C.

    1985-01-01

    A total of 127 patients with histologically proved diagnosis of carcinoma of the tonsillar region and soft palate were treated over the past ten years utilizing interstitial iridium-192 implants. Eighty patients were treated for primary tumors and 47 patients for either recurrent or persistent tumors after definitive irradiation and/or surgery. All patients with primary tumors were treated by a combination of external megavoltage irradiation and interstitial iridium-192 implants, whereas patients with recurrent tumors were treated by interstitial implants alone. In the primary group, 95% of patients with T1 and T2 lesions and 79% with T3 and T4 lesions achieved complete local tumor control. The three-year absolute disease-free survival rate was 72%. Seventy-five percent local tumor control was obtained in patients with recurrent disease, with two-year absolute disease-free survival of 42%. Treatment-related complications such as soft-tissue necrosis or osteoradionecrosis occurred in 6% of patients in the primary group and 23% in recurrent group. This treatment regimen offers an excellent locoregional control with no significant functional or esthetic impairment. Most patients with primary lesions who fail this regimen can be salvaged by surgery or reirradiation using interstitial implants

  1. Determination of the chemical yield on the Fricke dosimetry for 192Ir sources used in brachytherapy

    International Nuclear Information System (INIS)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de; Rosado, P.H.

    2015-01-01

    With the aim of developing a primary standard for the absorbed dose to water, for the 192 Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe +3 ), using Fricke dosimetry, for the energy of those sources . The G(Fe +3 ) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for 60 Co energy. The G(Fe +3 ) value for the average energy of 192 Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  2. 49 CFR 192.1009 - What must an operator report when compression couplings fail?

    Science.gov (United States)

    2010-10-01

    ... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1009 What must an operator report when compression...

  3. 49 CFR 192.943 - When can an operator deviate from these reassessment intervals?

    Science.gov (United States)

    2010-10-01

    ... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.943 When can an operator deviate from these reassessment...

  4. 49 CFR 192.909 - How can an operator change its integrity management program?

    Science.gov (United States)

    2010-10-01

    ... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.909 How can an operator change its integrity management...

  5. 49 CFR 192.911 - What are the elements of an integrity management program?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.911 What are the elements of an integrity management program...

  6. Unexpected Modulation of Recall B and T Cell Responses after Immunization with Rotavirus-like Particles in the Presence of LT-R192G

    Directory of Open Access Journals (Sweden)

    Christelle Basset

    2010-08-01

    Full Text Available LT-R192G, a mutant of the thermolabile enterotoxin of E. coli, is a potent adjuvant of immunization. Immune responses are generally analyzed at the end of protocols including at least 2 administrations, but rarely after a prime. To investigate this point, we compared B and T cell responses in mice after one and two intrarectal immunizations with 2/6 rotavirus-like particles (2/6-VLP and LT-R192G. After a boost, we found, an unexpected lower B cell expansion measured by flow cytometry, despite a secondary antibody response. We then analyzed CD4+CD25+Foxp3+ regulatory T cells (Tregs and CD4+CD25+Foxp3− helper T cells after in vitro (restimulation of mesenteric lymph node cells with the antigen (2/6-VLP, the adjuvant (LT-R192G or both. 2/6-VLP did not activate CD4+CD25+Foxp3− nor Foxp3+ T cells from non-immunized and 2/6-VLP immunized mice, whereas they did activate both subsets from mice immunized with 2/6-VLP in the presence of adjuvant. LT-R192G dramatically decreased CD4+CD25+Foxp3+ T cells from non-immunized and 2/6-VLP immunized mice but not from mice immunized with 2/6-VLP and adjuvant. Moreover, in this case, LT-R192G increased Foxp3 expression on CD4+CD25+Foxp3+ cells, suggesting specific Treg activation during the recall. Finally, when both 2/6-VLP and LT-R192G were used for restimulation, LT-R192G clearly suppressed both 2/6-VLP-specific CD4+CD25+Foxp3− and Foxp3+ T cells. All together, these results suggest that LT-R192G exerts different effects on CD4+CD25+Foxp3+ T cells, depending on a first or a second contact. The unexpected immunomodulation observed during the recall should be considered in designing vaccination protocols.

  7. 37 CFR 2.192 - Business to be conducted with decorum and courtesy.

    Science.gov (United States)

    2010-07-01

    ... Correspondence in Trademark Cases § 2.192 Business to be conducted with decorum and courtesy. Trademark... attorneys or agents are required to conduct their business with decorum and courtesy. Documents presented in... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Business to be conducted with...

  8. 49 CFR 192.489 - Remedial measures: Cast iron and ductile iron pipelines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Remedial measures: Cast iron and ductile iron... for Corrosion Control § 192.489 Remedial measures: Cast iron and ductile iron pipelines. (a) General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a...

  9. Empirical model with independent variable moments of inertia for triaxial nuclei applied to 76Ge and 192Os

    Science.gov (United States)

    Sugawara, M.

    2018-05-01

    An empirical model with independent variable moments of inertia for triaxial nuclei is devised and applied to 76Ge and 192Os. Three intrinsic moments of inertia, J1, J2, and J3, are varied independently as a particular function of spin I within a revised version of the triaxial rotor model so as to reproduce the energy levels of the ground-state, γ , and (in the case of 192Os) Kπ=4+ bands. The staggering in the γ band is well reproduced in both phase and amplitude. Effective γ values are extracted as a function of spin I from the ratios of the three moments of inertia. The eigenfunctions and the effective γ values are subsequently used to calculate the ratios of B (E 2 ) values associated with these bands. Good agreement between the model calculation and the experimental data is obtained for both 76Ge and 192Os.

  10. Balloon-based adjuvant radiotherapy in breast cancer: comparison between {sup 99m}Tc and HDR {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio Passos Ribeiro de; Lima, Carla Flavia de; Cuperschmid, Ethel Mizrahy, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2016-03-15

    Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with {sup 99m}Tc and balloon brachytherapy with high-dose-rate (HDR) {sup 192}Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and methods: simulations of implants with {sup 99m}Tc-filled and HDR {sup 192}Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: the {sup 99m}Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h{sup -1}.mCi{sup -1} and 0.190 cGyh{sup -1} at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh{sup -1}.mCi{sup -1}, respectively, for the HDR {sup 192}Ir balloon. An exposure time of 24 hours was required for the {sup 99m}Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR {sup 192}Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: temporary {sup 99m}Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR {sup 192}Ir balloon implantation, which is the current standard in clinical practice. (author)

  11. Radiation accident caused by an iridium-192 radiographic source

    International Nuclear Information System (INIS)

    Kumatori, T.; Hirashima, K.; Ishihara, T.; Kurisu, A.; Sugiyama, H.; Hashizume, T.

    1977-01-01

    Owing to the carelessness of a radiographer, six construction workers, aged from twenty to thirty, were accidentally exposed to gamma rays of a 192 Ir source for a non-destructive radiography. These exposed persons were not directly involved with radiographic work. One case revealed severe leucopenia and thrombopenia accompanied by moderate anaemia. In three cases including the case considered, skin lesions were observed on hands and hips, arising from close contact with a 192 Ir rod. The effects to the gonads consisted of impaired spermatogenesis in all cases and elevation of follicle-stimulating hormone in the sera of four cases. The ratio of one metabolite to another seemed to be more indicative of the injuries than the level of any given metabolite itself. In the physical estimate of the dose, the thermoluminescence intensity of rubies in the wrist watches of the exposed persons was measured, which was useful for the determination of the location of the source. The mean whole-body absorbed doses ranged from 10 to 133 rads. Local radiation doses were approximately 3000 to 9000 rads to the skin and 175 rads to the gonads of one case, respectively. The biological dose estimates were made by using the dose-response relations for 60 Co gamma rays and for Linac X-rays on the basis of the yields of dicentrics and rings. The doses were in the range of about 10 to 150 rads. Skin lesions and chromosome aberrations are still observed. (author)

  12. 49 CFR 192.907 - What must an operator do to implement this subpart?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.907 What must an operator do to implement this subpart? (a...

  13. 49 CFR 192.923 - How is direct assessment used and for what threats?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.923 How is direct assessment used and for what threats? (a...

  14. 49 CFR 192.905 - How does an operator identify a high consequence area?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.905 How does an operator identify a high consequence area? (a...

  15. 49 CFR 192.933 - What actions must be taken to address integrity issues?

    Science.gov (United States)

    2010-10-01

    ...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.933 What actions must be taken to address integrity issues? (a...

  16. 49 CFR 192.621 - Maximum allowable operating pressure: High-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... STANDARDS Operations § 192.621 Maximum allowable operating pressure: High-pressure distribution systems. (a) No person may operate a segment of a high pressure distribution system at a pressure that exceeds the... segment of a distribution system otherwise designed to operate at over 60 p.s.i. (414 kPa) gage, unless...

  17. Trinuclear rhenium(III) halide clusters with carboxylate ligands

    Science.gov (United States)

    Dougan, Jeffrey Steven

    Four mono(carboxylato)trirhenium complexes and three bis(carboxylato)trirhenium complexes have been synthesized and characterized, principally by mass spectrometry, with supporting evidence from X-ray diffraction. These compounds represent the first trinuclear rhenium carboxylate complexes. The reactions generally proceed readily under comparatively mild conditions. Mass spectrometry has again proved its usefulness as a technique in the field of metal cluster chemistry, having provided the initial identification of the products of the reactions studied. These compounds provide a further base to which future mass spectra of metal cluster compounds can be compared. Re-examination of a reaction reported by Taha and Wilkinson has also cast considerable doubt onto the validity of a conversion widely reported in the literature that transforms (Re3Cl9) x into [Re2(O2CCH3)4Cl 2]. We believe that the literature result is a consequence of the purity of the metal precursor, and suggest that the starting material in the earlier work may have contained ReCl4 or ReCl5. The importance of mass spectrometry in the characterization of the new compounds synthesized in this project has led to a thorough study of calculated isotopic distributions. The information gathered suggests that for isotopically simple molecules, the choice of algorithm for computing an isotopic distribution is unimportant. However, it is important to compute the mass spectrum of an isotopically complex molecule using an algorithm that can, if desired, show the underlying isotopic fine structure of a peak of interest. In the last chapter of this thesis, the results of a project in chemistry education research are presented. Predicting the success of students in general chemistry has long been of interest to the chemistry education community, and several factors have been identified as contributing factors. An off-hand comment by a student inspired an examination of whether continuity with the same instructor for

  18. Analysis of extreme ultraviolet spectra from laser produced rhenium plasmas

    Science.gov (United States)

    Wu, Tao; Higashiguchi, Takeshi; Li, Bowen; Suzuki, Yuhei; Arai, Goki; Dinh, Thanh-Hung; Dunne, Padraig; O'Reilly, Fergal; Sokell, Emma; Liu, Luning; O'Sullivan, Gerry

    2015-08-01

    Extreme ultraviolet spectra of highly-charged rhenium ions were observed in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a number of laser power densities. The maximum focused peak power density was 2.6 × 1014 W cm-2 for the former and 5.5 × 1012 W cm-2 for the latter. The Cowan suite of atomic structure codes and unresolved transition array (UTA) approach were used to calculate and interpret the emission properties of the different spectra obtained. The results show that n = 4-n = 4 and n = 4-n = 5 UTAs lead to two intense quasi-continuous emission bands in the 4.3-6.3 nm and 1.5-4.3 nm spectral regions. As a result of the different ion stage distributions in the plasmas induced by ps and ns laser irradiation the 1.5-4.3 nm UTA peak moves to shorter wavelength in the ps laser produced plasma spectra. For the ns spectrum, the most populated ion stage during the lifetime of this plasma that could be identified from the n = 4-n = 5 transitions was Re23+ while for the ps plasma the presence of significantly higher stages was demonstrated. For the n = 4-n = 4 4p64dN-4p54dN+1 + 4p64dN-14f transitions, the 4d-4f transitions contribute mainly in the most intense 4.7-5.5 nm region while the 4p-4d subgroup gives rise to a weaker feature in the 4.3-4.7 nm region. A number of previously unidentified spectral features produced by n = 4-n = 5 transitions in the spectra of Re XVI to Re XXXIX are identified.

  19. Double blocking in the superdeformed {sup 192}Tl nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Y; Carpenter, M P; Janssens, R V.F.; Ahmad, I; Henry, R; Khoo, T L; Lauritsen, T [Argonne National Lab., IL (United States); Soramel, F [Padova University, Padova (Italy); Pilotte, S [Ottawa Univ., ON (Canada); Lewis, J M; Riedinger, L L; Yu, C H [Tennessee Univ., Knoxville, TN (United States); Garg, U; Reviol, W [Notre Dame Univ., IN (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States)

    1992-08-01

    Six superdeformed bands have been found in the nucleus {sup 192}Tl. For two of the bands, the dynamic moment of inertia J{sup (2)} is found to be constant with the rotational frequency {Dirac_h}{omega}. This result can be understood in terms of Pauli blocking of quasiparticle alignments in intruder orbitals, and represents the first experimental evidence that the alignment of these intruders is responsible for the smooth rise in J{sup (2)} seen in other superdeformed nuclei of this mass region. (author). 18 refs., 2 figs.

  20. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Koudelkova, M.; Vinsova, H.; Konirova, R.; Ernestova, M.; Jedinakova-Krizova, V.; Tereesha, M.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing condition. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ ) with bentonite, the effect of solid: aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. The 8 days kinetics of the perrhenate and pertechnetate sorption on bentonite was described mathematically with a tendency to predict long-term behavior of studied systems. (authors)

  1. Clinical studies on the lymph flow of the esophagus by injecting sup(99m)Tc-rhenium colloid into the esophageal wall

    International Nuclear Information System (INIS)

    Baba, Masamichi; Tanabe, Gen; Nishi, Mitsumasa

    1985-01-01

    Using 29 operative cases lymph flow of the esophagus was investigated by injecting endoscopically sup(99m)Tc-Rhenium colloid. Rhenium colloid lymphoscintigraphy was made, and 30 -- 32 hours after injection RI up take (cpm/g) of resected lymph nodes was counted by scintillation counter. 1. RI up take of resected lymph nodes correspond with the lymphoscintigraphy of resected lymph nodes therefore, RI up take count was available to study the extra-mural lymph flow of the esophagus. 2. In the cases injected at upper part of the esophagus, the high counted RI up take was noted in bifurcation lymph nodes, upper mediastinal lymph nodes and bilateral supraclavicular lymph nodes. In the cases injected at middle part of the esophagus, bilateral supraclavicular lymph nodes, upper mediastinal lymph nodes and left gastric artery lymph nodes revealed the high RI up takes. In the cases injected at lower part of the esophagus, RI up take was highly noted in bifurcation lymph nodes, left gastric artery lymph nodes and celiac axis lymph nodes. In the cases injected at esophago-gastric junction, the high counted RI up take was noted in left gastric artery lymph nodes, celiac axis lymph nodes and the lymph nodes around the left renal vein. 3. In the cases injected at upper, middle parts of the esophagus, bilateral supraclavicular lymph nodes revealed the high RI up take. Some of these lymph nodes are regarded as directly connected with the extra-mural lymph vessls of the esophagus. Therefore, it was suggested that existence of ''direct lymph flow'' from which upper, middle intrathoracic esophagus directly connected to right supraclavicular lymph nodes. 4. It is important to perform bilateral modified neck dissection in case of upper, middle intrathoracic esophageal cancer and is important to dissect the lymph nodes around the left renal vein in case of esophago-gastric cancer and lower intrathoracic esophageal cancer. (J.P.N.)

  2. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  3. Comparison of air-kerma strength determinations for HDR 192Ir sources

    International Nuclear Information System (INIS)

    Rasmussen, Brian E.; Davis, Stephen D.; Schmidt, Cal R.; Micka, John A.; DeWerd, Larry A.

    2011-01-01

    Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) 192 Ir brachytherapy sources maintained by University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. Methods: The improved, laser-aligned seven-distance apparatus of University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR 192 Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the 192 Ir air-kerma calibration coefficient from the NIST air-kerma standards at 137 Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A wall for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. Results: The average measurements when using the inverse N K interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Conclusions: Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that

  4. Comparison of air-kerma strength determinations for HDR (192)Ir sources.

    Science.gov (United States)

    Rasmussen, Brian E; Davis, Stephen D; Schmidt, Cal R; Micka, John A; Dewerd, Larry A

    2011-12-01

    To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) (192)Ir brachytherapy sources maintained by the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. The improved, laser-aligned seven-distance apparatus of the University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR (192)Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the (192)Ir air-kerma calibration coefficient from the NIST air-kerma standards at (137)Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A(wall) for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. The average measurements when using the inverse N(K) interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to

  5. Downregulation of miR-192 causes hepatic steatosis and lipid accumulation by inducing SREBF1: Novel mechanism for bisphenol A-triggered non-alcoholic fatty liver disease.

    Science.gov (United States)

    Lin, Yi; Ding, Dongxiao; Huang, Qiansheng; Liu, Qiong; Lu, Haoyang; Lu, Yanyang; Chi, Yulang; Sun, Xia; Ye, Guozhu; Zhu, Huimin; Wei, Jie; Dong, Sijun

    2017-09-01

    Exposure to Bisphenol A (BPA) has been associated with the development of nonalcoholic fatty liver disease (NAFLD) but the underlying mechanism remains unclear. Given that microRNA (miRNA) is recognized as a key regulator of lipid metabolism and a potential mediator of environmental cues, this study was designed to explore whether exposure to BPA-triggered abnormal steatosis and lipid accumulation in the liver could be modulated by miR-192. We showed that male post-weaning C57BL/6 mice exposed to 50μg/kg/day of BPA by oral gavage for 90days displayed a NAFLD-like phenotype. In addition, we found in mouse liver and human HepG2 cells that BPA-induced hepatic steatosis and lipid accumulation were associated with decreased expression of miR-192, upregulation of SREBF1 and a series of genes involved in de novo lipogenesis. Downregulation of miR-192 in BPA-exposed hepatocytes could be due to defective pre-miR-192 processing by DROSHA. Using HepG2 cells, we further confirmed that miR-192 directly acted on the 3'UTR of SREBF1, contributing to dysregulation of lipid homeostasis in hepatocytes. MiR-192 mimic and lentivirus-mediated overexpression of miR-192 improved BPA-induced hepatic steatosis by suppressing SREBF1. Lastly, we noted that lipid accumulation was not a strict requirement for developing insulin resistance in mice after BPA treatment. In conclusion, this study demonstrated a novel mechanism in which NAFLD associated with BPA exposure arose from alterations in the miR-192-SREBF1 axis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Synthesis and investigation of CrB{sub 4}, MnB{sub 4} and new ternary chromium and rhenium manganese borides; Synthese und Untersuchung von CrB{sub 4}, MnB{sub 4} sowie neuen ternaeren Chrom- und Rheniummanganboriden

    Energy Technology Data Exchange (ETDEWEB)

    Knappschneider, Arno

    2014-10-13

    In the present work single crystals of the tetraborides of chromium and manganese have been grown and allowed a structure refinement of the compounds. Furthermore the physical characteristics for example hardness, electronic properties and magnetism were been determined. Also the ternary tetraboride phase of chromium and manganese was synthesized and a new ternary rhenium manganese diboride could be obtained.

  7. 49 CFR 192.476 - Internal corrosion control: Design and construction of transmission line.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Design and... STANDARDS Requirements for Corrosion Control § 192.476 Internal corrosion control: Design and construction... the risk of internal corrosion. At a minimum, unless it is impracticable or unnecessary to do so, each...

  8. Development and characterisation of iridium-192 seeds for brachytherapy treatment of ocular tumors

    International Nuclear Information System (INIS)

    Peleias Jr, F.S.; Zeituni, C.A.; Souza, C.D.; Rostelato, M.E.CM.; Mattos, F.R.; Banega, M.A.G.; Rodrigues, B.T.; Tiezzi, R.; Oliveira, T.B.; Feher, A.; Moura, J.A.; Costa, O.L.

    2014-01-01

    Even ocular tumors are not amongst the cases with a high incidence, they affect the population, particularly children. The Institute of Energy and Nuclear Research (IPEN-CNEN/SP) in partnership with Escola Paulista de Medicina (UNIFESP), created a project to develop an alternative treatment for ophthalmic cancer that uses iridium-192 seeds in brachytherapy. This work aims to study and develop a seed of iridium-192 from a platinum-iridium alloy The prototype seed has a 3.0 mm long core sealed by a titanium capsule of 0.8 mm of outer diameter, 0.05 mm of wall thickness and 4.5 mm long. We developed a methodology that covered: characterisation of the material used in the core, creation of a device for neutron activation of the cores and leakage tests. The results show that this methodology is feasible. As a suggestion for future work, studies regarding metrology and dosimetry of these sources should be carried out. (authors)

  9. Comparison of the cost between 60Co and 192Ir, as the sources for high-dose-rate remote control afterloading systems (HDR-RALS)

    International Nuclear Information System (INIS)

    Ogata, Hitoshi

    1994-01-01

    High-Dose-Rate remote control afterloading systems (HDR-RALS) installing 60 Co sources have been prevailing currently in Japan. The survey conducted by Japan Isotope Association (JIA) reports that 180 machines are at working condition. Although the wide prevalence of the HDR-RALS, the stable supply of 60 Co is becoming difficult because of the short availability of raw materials. The supply of 60 Co is planned to be terminated in March 1996. In place of 60 Co, 192 Ir is going to be produced in 1996. The size of 192 Ir, which is much smaller than that of 60 Co, may facilitate broader clinical usability. On the other hand, for the reason that the half life of 192 Ir (73.8 days) is much shorter than that of 60 Co (5.27 years), several exchanges of the sources in a year are necessary. This report analyses the difference of the cost between 60 Co and 192 Ir as the sources for HDR-RALS. As the cost of the 60 Co sources is dependent on the distance from Tokyo. Radiation activity, etc., the cost-calculation was done on the basis the 60 Co sources were installed for the HDR-RALS systems in Yamanashi Central Hospital. The total cost of 60 Co is 3,377,000 yen on the data from JIA. According to the half life of 5.27 years, the available duration can be thought as 7 years and the monthly cost be calculated as about 40,000 yen. In case of 192 Ir, the prices for Buchler' system and Nucletron's system are 800,000 yen and 990,000 yen respectively. Concerning the shortness of the half life, an exchange in every 3 months is ideal. Therefore the monthly cost of 192 Ir would be 260,000-330,000 yen. Consequently the cost-ratio for 192 Ir and 60 Co would become 6.7-8.3. The cost of intracavitary irradiation is controlled by the government as 10,000 yen per treatment in Japan. If this setting remains the same for HDR-RALS installing 192 Ir, almost all the facilities of radiation therapy would suffer from the cost-income inbalance in the near future. (author)

  10. 49 CFR 192.935 - What additional preventive and mitigative measures must an operator take?

    Science.gov (United States)

    2010-10-01

    ... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.935 What additional preventive and mitigative...

  11. Pharmacokinetic properties of new antitumor radiopharmaceutical on the basis of diamond nanoporous composites labeled with rhenium-188

    International Nuclear Information System (INIS)

    Petriev, V M; Tishchenko, V K; Kuril’chik, A A; Skvortsov, V G

    2017-01-01

    Today the development of address therapeutic radionuclide delivery systems directly to tumor tissue is of current interest. It can be achieved by the design of drug containers of specific sizes and shapes from carbon-based composite materials. It will be allowed to enhance the efficacy of anticancer therapy and avoid serious side effects. In this work we studied the pharmacokinetic properties of nanodiamond nanoporous composite labeled with rhenium-188 in rats with hepatocholangioma PC-1 after intratumoral injection. It was established that substantial part of injected radioactivity remained in tumor tissue. Within three hours after 188 Re-nanoporous composites injection activity in tumor constituted 79.1–91.3% of injected dose (ID). Then activity level declined to 45.9% ID at 120 hours. No more than 1.34% ID entered the bloodstream. In soft organs and tissues, except thyroid gland, the content of compound didn’t exceed 0.3% ID/g. The highest activity in thyroid gland was 6.95% ID/g. In conclusion, received results suggest 188 Re-nanoporous composites can be promising radionuclide delivery systems for cancer treatment. (paper)

  12. 49 CFR 192.112 - Additional design requirements for steel pipe using alternative maximum allowable operating...

    Science.gov (United States)

    2010-10-01

    ... (incorporated by reference, see § 192.7); or (ii) American Society of Mechanical Engineers (ASME) B31.8.... Certification must address material properties such as chemistry, minimum yield strength and minimum wall...

  13. 49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.

    Science.gov (United States)

    2010-10-01

    ... (SCADA) system, other leak detection system, or an alternative method of control. (iii) Remote valve... outs, leakage, or other activities or conditions affecting the safety operation of the pipeline. (ii... requirements of § 192.707(d) except in agricultural areas, large water crossings or swamp, steep terrain, or...

  14. Iridium-192 curietherapy for T1 and T2 epidermoid carcinomas of the floor of mouth

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Grimard, L.; Raynal, M.; Haddad, E.; Piedbois, P.; Martin, M.; Marinello, G.; Nair, R.C.; Le Bourgeois, J.P.; Pierquin, B.

    1990-01-01

    From 1970 to 1986, 117 patients with T1 (47) or T2 (70) epidermoid carcinomas of the floor of the mouth (SCC) were treated by iridium-192 implantation (192 Ir). The dose was prescribed according to the Paris System and varied over those years. Follow-up information was available on 116 patients. There were 46 T1N0, 47 T2N0, and 23 T2N1-3. Neck management varied for the 93 N0 patients consisting of surveillance (24 T1, 17 T2) or elective neck dissection (22 T1:all pN-, 30 T2: 20 pN-, 10 pN+). Cause specific survival rates were 94% for T1N0, 61.5% for T2N0, and 28% for T2N1-3 at 5 years. Primary local control was 93.5%, 74.5%, and 65%, respectively, and 98%, 79%, and 65% after salvage. Patients with gingival extension or a tumor size over 3 cm (T2b) had a local control of 50% (9/18) and 58% (15/26), respectively. Nodal control was 93.5% for Stage I, 85% for Stage II, and 48% for T2N1-3 patients. There was no difference in nodal control with regard to treatment policy for Stage I-II patients. There were few complications including three deaths: two from surgery and one from 192 Ir. Nodal status, tumor size defined as T1, T2a (less than or equal to 3 cm), T2b (greater than 3 cm), and gingival extension were the only independent prognostic factors. The management of T1N0 and T2N0 SCC by 192 Ir to a dose of 65 or 70 Gy, using the Paris System, is recommended for lesions 3 cm or less and without gingival extension

  15. 49 CFR 192.945 - What methods must an operator use to measure program effectiveness?

    Science.gov (United States)

    2010-10-01

    ... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.945 What methods must an operator use to measure program...

  16. Syntheses and structures of technetium(V) and rhenium(V) oxo complexes of peptide having KYC-sequence

    International Nuclear Information System (INIS)

    Takayama, T.; Suzuki, K.; Sekine, T.; Kudo, H.

    2000-01-01

    Technetium(V) and rhenium(V) oxo complexes of a peptide having a KYC-sequence such as KYCAR (H 3 L 5 ) and KYCAREPPTRTNAYQGQG-NH 2 (H 3 L 18 ) were synthesized, and structures of the complexes were characterized by spectroscopic techniques. All of the complexes were synthesized by the ligand exchange reaction of [(n-C 4 H 9 ) 4 N][MOCl 4 ] (M = 99 Tc, Re) with peptide in methanol or dimethylformamide solution. These complexes have a square pyramidal structure with an oxo ligand at the apical position. The peptide is coordinated to a metal atom through N amine of lysine. S thiol of cysteine, and N amide of tyrosine and cysteine in the equatorial plane. A lysine (CH 2 ) 4 NH 2 group of the L 5 ligand has the syn conformation with respect to metal-oxo bonding in the complex. The syn isomer was selectively formed in the ligand exchange reaction. The conversion of the syn isomer to the anti isomer was observed only for syn-[ReO(L 5 )], in which the coordination of water to the trans position of the oxo ligand was involved. (orig.)

  17. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    International Nuclear Information System (INIS)

    Kucera, J.; Lucanikova, M.; Czech Technical Univ., Prague

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng x g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng x g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of ∼ 10 ng x g -1 was found. Significantly elevated values of Re, up to 90 ng x g -1 were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggested possible competition between Re and Tc in the accumulation process. (author)

  18. Radiation levels in Cath Lab and occupational exposures during manual 192Ir intracoronary brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Tripathi, U.B.; Bhatt, B.C.

    2001-01-01

    Intracoronary brachytherapy is a new modality of radiation therapy and is being used to reduce the rate of restenosis after angioplasty. Clinical trials for evaluation of safety and efficacy of manually implanted 192 Ir seed ribbons are underway at various cardiology centres in India. 192 Ir emits high energy gamma rays (0.136 -1.06 MeV), which causes concern regarding safety of the personnel when these sources are manually used in the cardiac catheterization laboratory (Cath Lab) for intracoronary irradiation. Radiation levels in Cath Lab and exposures to personnel have been measured at 6 different cardiology centres in the country during 8 different clinical trials using radiation survey meter, personnel monitoring badges and pocket dosimeters. Activities of 192 Ir seed ribbons used in these clinical trials were in the range of 5.55 - 14.8 GBq. Measured radiation levels behind the mobile lead shields, at the top of lead shields, near the patient head, near the patient toes and at the main door of the Cath Lab were in the range of 2.6-20, 50-256, 385-450, 22-225 and 2-16 μSv/hr/3.7GBq, respectively. Measured effective doses to occupational workers were in range of 14-100 μSv/procedure/3.7GBq. Based on these measurements, user institutions have been advised to use lead glass mounted L-shaped mobile lead shields with proper orientation during clinical trials, avoid unwanted occupancy in the Cath Lab and around the patient during irradiation and use conveniently long forceps or tongs for implantation and removal of sources. (author)

  19. 41 CFR 102-192.15 - How are “I”, “you”, “me”, “we”, and “us” used in this part?

    Science.gov (United States)

    2010-07-01

    ... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION ADMINISTRATIVE PROGRAMS 192-MAIL MANAGEMENT Introduction to this Part § 102-192.15 How are “I”, “you”, “me”, “we... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false How are âIâ, âyouâ, âmeâ...

  20. Safety and Efficacy of 188-Rhenium-Labeled Antibody to Melanin in Patients with Metastatic Melanoma

    Directory of Open Access Journals (Sweden)

    M. Klein

    2013-01-01

    Full Text Available There is a need for effective “broad spectrum” therapies for metastatic melanoma which would be suitable for all patients. The objectives of Phase Ia/Ib studies were to evaluate the safety, pharmacokinetics, dosimetry, and antitumor activity of 188Re-6D2, a 188-Rhenium-labeled antibody to melanin. Stage IIIC/IV metastatic melanoma (MM patients who failed standard therapies were enrolled in both studies. In Phase Ia, 10 mCi 188Re-6D2 were given while unlabeled antibody preload was escalated. In Phase Ib, the dose of 188Re-6D2 was escalated to 54 mCi. SPECT/CT revealed 188Re-6D2 uptake in melanoma metastases. The mean effective half-life of 188Re-6D2 was 12.4 h. Transient HAMA was observed in 9 patients. Six patients met the RECIST criteria for stable disease at 6 weeks. Two patients had durable disease stabilization for 14 weeks and one for 22 weeks. Median overall survival was 13 months with no dose-limiting toxicities. The data demonstrate that 188Re-6D2 was well tolerated, localized in melanoma metastases, and had antitumor activity, thus warranting its further investigation in patients with metastatic melanoma.

  1. Rhenium(5) and molybdenum(5) complexes with 4',4[sup (]5[sup )]-divaleryldibenzo-18-crown-6. Kompleksnye soedineniya reniya(5) i molibdena(5) s 4',4[sup (]5[sup )]-divalerildibenzo-18-kraun-6

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G; Tashmukhamedova, A K; Basitova, S M [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1993-02-01

    Methods for synthesizing oxohalide complexes of rhenium and molybdenum with +5 oxidation degree with 4',4[sup (5)]-divaleryldibenzo-18-crown-6 were developed. Content and composition of prepared compounds were investigated by the methods of element analysis, crystal optics, conductometry, IR spectroscopy in the near and far regions, thermogravimetry. Oxidation degree of the complex-forming metal was determined. It was established that composition of the compounds coressponded to the general formula MOLX [sub [center dot

  2. Water equivalency evaluation of PRESAGE® dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sources

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Baldock, Clive

    2010-11-01

    A major challenge in brachytherapy dosimetry is the measurement of steep dose gradients. This can be achieved with a high spatial resolution three dimensional (3D) dosimeter. PRESAGE® is a polyurethane based dosimeter which is suitable for 3D dosimetry. Since an ideal dosimeter is radiologically water equivalent, we have investigated the relative dose response of three different PRESAGE® formulations, two with a lower chloride and bromide content than original one, for Cs-137 and Ir-192 brachytherapy sources. Doses were calculated using the EGSnrc Monte Carlo package. Our results indicate that PRESAGE® dosimeters are suitable for relative dose measurement of Cs-137 and Ir-192 brachytherapy sources and the lower halogen content PRESAGE® dosimeters are more water equivalent than the original formulation.

  3. Extrahepatic bile duct carcinoma treated by intraluminal irradiation with iridium-192 wire. Report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, H; Kuroda, T; Uchida, H [Osaka Univ. (Japan). Faculty of Medicine

    1980-08-01

    A 57-year-old male with obstructive jaundice was diagnosed extrahepatic bile duct carcinoma at bifurcation by percutaneous transhepatic cholangiography (PTC). He was treated 3,300 rad of external irradiation and then intraluminal irradiation using the Iridium-192 wire by two times with the aid of PTC internal drainage, each was given by the dose of 1,600 rad at 5 mm inside the tumor from the PTC-tube. He had been well for about 1 year and then died because of ascites and cachexia. Autopsy revealed only microscopic tumor cells remaining around the common duct below the cystic junction. It was confirmed that intraluminal irradiation using the Iridium-192 wire was potentially curable and easily applicable to the bile duct carcinoma.

  4. Variable-temperature sample system for ion implantation at -192 to +5000C

    International Nuclear Information System (INIS)

    Fuller, C.T.

    1978-04-01

    A variable-temperature sample system based on exchange-gas coupling was developed for ion-implantation use. The sample temperature can be controlled from -192 0 C to +500 0 C with rapid cooling. The system also has provisions for focusing and alignment of the ion beam, electron suppression, temperature monitoring, sample current measuring, and cryo-shielding. Design considerations and operating characteristics are discussed. 5 figures

  5. Maternal exposure to floricultural work during pregnancy, PON1 Q192R polymorphisms and the risk of low birth weight

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Banda, G.; Blanco-Munoz, J. [Population Health Research Center, National Institute of Public Health, Avenida Universidad 655, Colonia Santa Maria Ahuacatitlan, 62508 Cuernavaca, Morelos (Mexico); Lacasana, M., E-mail: marina.lacasana.easp@juntadeandalucia.es [Andalusian School of Public Health, Campus Universitario de la Cartuja, Cuesta del Observatorio, 4, 18080 Granada (Spain); CIBER of Epidemiology and Public Health (CIBERESP) (Spain); Rothenberg, S.J. [Population Health Research Center, National Institute of Public Health, Avenida Universidad 655, Colonia Santa Maria Ahuacatitlan, 62508 Cuernavaca, Morelos (Mexico); Center of Research and Advanced Studies, National Institute Polytechnic, Department of Toxicology, Av, Instituto Politecnico Nacional No. 2508, Col. San Pedro Zacatenco, Deleg. Gustavo A. Madero, 07360 Mexico, D.F. (Mexico); Aguilar-Garduno, C. [Andalusian School of Public Health, Campus Universitario de la Cartuja, Cuesta del Observatorio, 4, 18080 Granada (Spain); Andalusian Observatory of Environmental Health, Campus Universitario de la Cartuja, Cuesta del Observatorio, 4, 18080 Granada (Spain); Gamboa, R. [Department of Physiology, National Institute of Cardiology ' Ignacio Chavez' , Juan Badiano 4, Section XVI, 14080, Mexico DF (Mexico); Perez-Mendez, O. [Department of Molecular Biology and cardiovascular Diseases Genomic and Proteomic, National Institute of Cardiology ' Ignacio Chavez' , Juan Badiano 4, Section XVI, 14080, Mexico DF (Mexico)

    2009-10-15

    Background: Although there is evidence from animal studies of impaired reproductive function by exposure to organophosphates (OP), the effects on birth weight have not been sufficiently evaluated in epidemiological studies. Paraoxonase (PON1) detoxifies organophosphates by cleavage of active oxons. Some PON1 gene polymorphisms could reduce the enzyme activity and increase susceptibility to OP toxicity. Objective: To assess the association between maternal exposure to floriculture during pregnancy and the risk of low birth weight (< 2500 g) in their offspring, as well as to evaluate the interaction between this exposure and maternal genotype for PON1 Q192R polymorphisms. Materials and methods: A cross sectional study was carried out in two Mexican states (States of Mexico and Morelos) with high frequencies of greenhouse activity. We interviewed and collected blood samples from 264 females (floriculturists or partners of floricultural workers) who became pregnant during the 10 years prior to the interview. The questionnaire measured socioeconomic characteristics, tobacco and alcohol consumption, diseases and occupational and reproductive history. We also applied a food frequency questionnaire. Information was obtained pertaining to 467 pregnancies. DNA was extracted from white cells, and PON1 genotype was determined by Restriction Fragment Length Polymorphism for Q192R polymorphisms. Results were analyzed with generalized estimating equations models. Results: After adjusting for potential confounders, we detected a statistically significant interaction between maternal exposure to flower growing work during pregnancy and PON1 Q192R polymorphisms on risk of low birth weight. The risk of having a baby with LBW is nearly six times higher if a mother is a floriculture worker during pregnancy and has PON1 192RR genotype (OR 5.93, 95% CI 1.28, 27.5). Conclusion: These results suggest that the interaction between maternal floriculture work during pregnancy and 192RR PON1

  6. Maternal exposure to floricultural work during pregnancy, PON1 Q192R polymorphisms and the risk of low birth weight

    International Nuclear Information System (INIS)

    Moreno-Banda, G.; Blanco-Munoz, J.; Lacasana, M.; Rothenberg, S.J.; Aguilar-Garduno, C.; Gamboa, R.; Perez-Mendez, O.

    2009-01-01

    Background: Although there is evidence from animal studies of impaired reproductive function by exposure to organophosphates (OP), the effects on birth weight have not been sufficiently evaluated in epidemiological studies. Paraoxonase (PON1) detoxifies organophosphates by cleavage of active oxons. Some PON1 gene polymorphisms could reduce the enzyme activity and increase susceptibility to OP toxicity. Objective: To assess the association between maternal exposure to floriculture during pregnancy and the risk of low birth weight (< 2500 g) in their offspring, as well as to evaluate the interaction between this exposure and maternal genotype for PON1 Q192R polymorphisms. Materials and methods: A cross sectional study was carried out in two Mexican states (States of Mexico and Morelos) with high frequencies of greenhouse activity. We interviewed and collected blood samples from 264 females (floriculturists or partners of floricultural workers) who became pregnant during the 10 years prior to the interview. The questionnaire measured socioeconomic characteristics, tobacco and alcohol consumption, diseases and occupational and reproductive history. We also applied a food frequency questionnaire. Information was obtained pertaining to 467 pregnancies. DNA was extracted from white cells, and PON1 genotype was determined by Restriction Fragment Length Polymorphism for Q192R polymorphisms. Results were analyzed with generalized estimating equations models. Results: After adjusting for potential confounders, we detected a statistically significant interaction between maternal exposure to flower growing work during pregnancy and PON1 Q192R polymorphisms on risk of low birth weight. The risk of having a baby with LBW is nearly six times higher if a mother is a floriculture worker during pregnancy and has PON1 192RR genotype (OR 5.93, 95% CI 1.28, 27.5). Conclusion: These results suggest that the interaction between maternal floriculture work during pregnancy and 192RR PON1

  7. Effect of the lead screen in the radiographic image using iridium 192 as a source

    International Nuclear Information System (INIS)

    Garate Rojas, M.

    1983-01-01

    It's presented the effect of the lead screen in the image obtained on an impressionable film used in industrial gammagraphy. The source used was Iridium 192 and the tests were simulated like a real inspection. (E.G.) [pt

  8. Comparison of air-kerma strength determinations for HDR {sup 192}Ir sources

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Brian E.; Davis, Stephen D.; Schmidt, Cal R.; Micka, John A.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2011-12-15

    Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) {sup 192}Ir brachytherapy sources maintained by University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. Methods: The improved, laser-aligned seven-distance apparatus of University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR {sup 192}Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the {sup 192}Ir air-kerma calibration coefficient from the NIST air-kerma standards at {sup 137}Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A{sub wall} for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. Results: The average measurements when using the inverse N{sub K} interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Conclusions: Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well

  9. A new amperometric glucose biosensor based on screen printed carbon electrodes with rhenium(IV - oxide as a mediator

    Directory of Open Access Journals (Sweden)

    ALBANA VESELI

    2012-11-01

    Full Text Available Rhenium(IV-oxide, ReO2, was used as a mediator for carbon paste (CPE and screen printed carbon (SPCE electrodes for the catalytic amperometric determination of hydro-gen peroxide, whose overpotential for the reduction could be lowered to -0.1 V vs. Ag/AgCl in flow injection analysis (FIA using phosphate buffer (0.1 M, pH=7.5 as a carrier. For hydrogen peroxide a detection limit (3σ of 0.8 mg L-1 could be obtained.ReO2-modified SPCEs were used to design biosensors with a template enzyme, i.e. glucose oxidase, entrapped in a Nafion membrane. The resulting glucose sensor showed a linear dynamic range up to 200 mg L-1 glucose with a detection limit (3σ of 0.6 mg L-1. The repeatability was 2.1 % RSD (n = 5 measurements, the reproducibility 5.4 % (n = 5 sensors. The sensor could be applied for the determination of glucose in blood serum in good agreement with a reference method.

  10. Analysis of extreme ultraviolet spectra from laser produced rhenium plasmas

    International Nuclear Information System (INIS)

    Wu, Tao; Dunne, Padraig; O’Reilly, Fergal; Sokell, Emma; Liu, Luning; O’Sullivan, Gerry; Higashiguchi, Takeshi; Suzuki, Yuhei; Arai, Goki; Dinh, Thanh-Hung; Li, Bowen

    2015-01-01

    Extreme ultraviolet spectra of highly-charged rhenium ions were observed in the 1–7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a number of laser power densities. The maximum focused peak power density was 2.6 × 10 14 W cm −2 for the former and 5.5 × 10 12 W cm −2 for the latter. The Cowan suite of atomic structure codes and unresolved transition array (UTA) approach were used to calculate and interpret the emission properties of the different spectra obtained. The results show that n = 4-n = 4 and n = 4-n = 5 UTAs lead to two intense quasi-continuous emission bands in the 4.3–6.3 nm and 1.5–4.3 nm spectral regions. As a result of the different ion stage distributions in the plasmas induced by ps and ns laser irradiation the 1.5–4.3 nm UTA peak moves to shorter wavelength in the ps laser produced plasma spectra. For the ns spectrum, the most populated ion stage during the lifetime of this plasma that could be identified from the n = 4-n = 5 transitions was Re 23+ while for the ps plasma the presence of significantly higher stages was demonstrated. For the n = 4-n = 4 4p 6 4d N -4p 5 4d N+1  + 4p 6 4d N−1 4f transitions, the 4d-4f transitions contribute mainly in the most intense 4.7–5.5 nm region while the 4p-4d subgroup gives rise to a weaker feature in the 4.3–4.7 nm region. A number of previously unidentified spectral features produced by n = 4-n = 5 transitions in the spectra of Re XVI to Re XXXIX are identified. (paper)

  11. 49 CFR 192.925 - What are the requirements for using External Corrosion Direct Assessment (ECDA)?

    Science.gov (United States)

    2010-10-01

    ... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.925 What are the requirements for using...

  12. 49 CFR 192.927 - What are the requirements for using Internal Corrosion Direct Assessment (ICDA)?

    Science.gov (United States)

    2010-10-01

    ... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.927 What are the requirements for using...

  13. Quality assurance of HDR 192Ir sources using a Fricke dosimeter.

    Science.gov (United States)

    Austerlitz, C; Mota, H; Almeida, C E; Allison, R; Sibata, C

    2007-04-01

    A prototype of a Fricke dosimetry system consisting of a 15 x 15 x 15 cm3 water phantom made of Plexiglas and a 11.3-ml Pyrex balloon fitted with a 0.2 cm thick Pyrex sleeve in its center was created to assess source strength and treatment planning algorithms for use in high dose rate (HDR) 192Ir afterloading units. In routine operation, the radioactive source is positioned at the end of a sleeve, which coincides with the center of the spherical balloon that is filled with Fricke solution, so that the solution is nearly isotropically irradiated. The Fricke system was calibrated in terms of source strength against a reference well-type ionization chamber, and in terms of radial dose by means of an existing algorithm from the HDR's treatment planning system. Because the system is based on the Fricke dosimeter itself, for a given type and model of 192Ir source, the system needs initial calibration but no recalibration. The results from measurements made over a 10 month period, including source decay and source substitutions, have shown the feasibility of using such a system for quality control (QC) of HDR afterloading equipment, including both the source activity and treatment planning parameters. The benefit of a large scale production and the use of this device for clinical HDR QC audits via mail are also discussed.

  14. An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.

    Science.gov (United States)

    Toye, W C; Das, K R; Todd, S P; Kenny, M B; Franich, R D; Johnston, P N

    2007-09-07

    The dose anisotropy around a (192)Ir HDR source in a water phantom has been measured using MOSFETs as relative dosimeters. In addition, modeling using the EGSnrc code has been performed to provide a complete dose distribution consistent with the MOSFET measurements. Doses around the Nucletron 'classic' (192)Ir HDR source were measured for a range of radial distances from 5 to 30 mm within a 40 x 30 x 30 cm(3) water phantom, using a TN-RD-50 MOSFET dosimetry system with an active area of 0.2 mm by 0.2 mm. For each successive measurement a linear stepper capable of movement in intervals of 0.0125 mm re-positioned the MOSFET at the required radial distance, while a rotational stepper enabled angular displacement of the source at intervals of 0.9 degrees . The source-dosimeter arrangement within the water phantom was modeled using the standardized cylindrical geometry of the DOSRZnrc user code. In general, the measured relative anisotropy at each radial distance from 5 mm to 30 mm is in good agreement with the EGSnrc simulations, benchmark Monte Carlo simulation and TLD measurements where they exist. The experimental approach employing a MOSFET detection system of small size, high spatial resolution and fast read out capability allowed a practical approach to the determination of dose anisotropy around a HDR source.

  15. Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy

    International Nuclear Information System (INIS)

    Ures, Ma Cristina; Savio, Eduardo; Malanga, Antonio; Fernández, Marcelo; Paolino, Andrea; Gaudiano, Javier

    2002-01-01

    Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium ( 188 Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188 Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188 Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188 Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans

  16. Interstitial hyperthermia and iridium-192 treatment alone vs. interstitial iridium-192 treatment/hyperthermia and low dose cisplatinum infusion in the treatment of locally advanced head and neck malignancies

    International Nuclear Information System (INIS)

    Schreiber, David P.; Overett, Thomas K.

    1995-01-01

    Purpose: To determine whether the addition of low dose platinum infusional chemotherapy adds to the effectiveness of interstitial hyperthermia/iridium-192 management of locally advanced head and neck malignancies. Methods and Materials: From 1987 to 1993, 36 patients with locally advanced head and neck malignancies were treated locally with interstitial hyperthermia and iridium-192 as part or all of their management. Twenty-two of the above-mentioned patients also received low dose infusional cisplatinum chemotherapy at 20 mg/M 2 per day during the time of the implant. No patient received greater than 100 mg/M 2 total dose. Implant times ranged from 38.5 to 134 h and total doses delivered with the radiation implants ranged from 15 to 39.9 Gy. Average implant volume was 50 cc. Twenty-three patients received external beam irradiation supplementation in a dose range from 25.2 to 64 Gy. Results: Median follow-up for the entire group was 8, months with 7 months for the chemotherapy group vs. 12 months for the no-chemotherapy group. Freedom from relapse rates for the chemotherapy group vs. the no-chemotherapy group were 70% at 41 months vs. 63% at 60 months, p not significant (p = NS). Overall survival by Life Table Analysis was 28% for the chemotherapy group at 41 months vs. 31% for the no-chemotherapy group at 60 months (p = NS). Complete response (CR) rates were 93% for the chemotherapy group vs. 86% for the no-chemotherapy group. Seven patients in the chemotherapy group had recurrent disease and four patients in the no-chemotherapy group were being treated for recurrent disease. Complication rates were similar in both groups, with two patients in the chemotherapy arm requiring hyperbaric oxygen treatments and one patient in the no-chemotherapy arm requiring hyperbaric oxygen treatments (for soft tissue necrosis). Conclusion: It appears that low dose platinum infusional chemotherapy can be added safely to patients receiving interstitial iridium-192 implants along with

  17. Syntheses and structures of technetium(V) and rhenium(V) oxo complexes of peptide having KYC-sequence

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, T.; Suzuki, K.; Sekine, T.; Kudo, H. [Dept. of Chemistry, Tohoku Univ., Sendai (Japan)

    2000-07-01

    Technetium(V) and rhenium(V) oxo complexes of a peptide having a KYC-sequence such as KYCAR (H{sub 3}L{sup 5}) and KYCAREPPTRTNAYQGQG-NH{sub 2} (H{sub 3}L{sup 18}) were synthesized, and structures of the complexes were characterized by spectroscopic techniques. All of the complexes were synthesized by the ligand exchange reaction of [(n-C{sub 4}H{sub 9}){sub 4}N][MOCl{sub 4}] (M = {sup 99}Tc, Re) with peptide in methanol or dimethylformamide solution. These complexes have a square pyramidal structure with an oxo ligand at the apical position. The peptide is coordinated to a metal atom through N{sub amine} of lysine. S{sub thiol} of cysteine, and N{sub amide} of tyrosine and cysteine in the equatorial plane. A lysine (CH{sub 2}){sub 4}NH{sub 2} group of the L{sup 5} ligand has the syn conformation with respect to metal-oxo bonding in the complex. The syn isomer was selectively formed in the ligand exchange reaction. The conversion of the syn isomer to the anti isomer was observed only for syn-[ReO(L{sup 5})], in which the coordination of water to the trans position of the oxo ligand was involved. (orig.)

  18. Bone marrow adsorbed dose of rhenium-186-HEDP and the relationship with decreased platelet counts

    International Nuclear Information System (INIS)

    Klerk, J.M.H. de; Dieren, E.B. van; Schip, A.D. van het

    1996-01-01

    Rhenium-186(Sn)-1,1-hydroxyethylidene diphosphonate ( 186 Re-HEDP) has been used for palliation of metastatic bone pain. The purpose of this study was to find a relationship between the bone marrow absorbed dose and the toxicity, expressed as the percentage decrease in the peripheral blood platelet count. The bone marrow absorbed dose was calculated according to the MIRD model using data obtained from ten treatments of patients suffering from metastatic prostate cancer; noninvasive and pharmacokinetic method were used. The bone marrow doses were related to toxicity using the pharmacodynamic sigmoid E max model. The mean bone marrow absorbed doses using the noninvasive and pharmacokinetic methods were in a close range to each other (1.07 mGy/MBq and 1.02 mGy/MBq, respectively). There was a good relationship between the toxicity and the bone marrow absorbed dose (r = 0.80). Furthermore, the EDrm 50 (i.e., the bone marrow absorbed dose producing a 50% platelet decrease) to bone marrow for 186 Re-HEDP was on the order of 2 Gy. Although the function of normal bone marrow is affected by metastases in patients with metastatic bone disease, the MIRD model can be used to relate toxicity to the bone marrow absorbed dose after a therapeutic dosage of 186 Re-HEDP. 33 refs., 1 fig., 1 tab

  19. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  20. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Aasa

    2007-11-01

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192 Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192 Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the ±3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192 Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  1. Flushing-free film test of "1"9"2Ir accuracy of position and step distance for afterloading systems

    International Nuclear Information System (INIS)

    Lu Feng; Chen Rui; Shang Yunying; Chen Yue; Min Nan; Chen Yingmin; Deng Daping

    2014-01-01

    Objective: To study the method of measuring the position accuracy and the step distance accuracy of afterloading system with "1"9"2Ir source by using flushing-free film. Methods: The position accuracy and the step distance accuracy of a China-made afterloading system with "1"9"2Ir source was measured by using GAFCHROMIC"® EBT"3 flushing-free film. The film was scanned to proper image format, required by dose analysis software, by EPSON PREFACTION V700 PHOTO scanner. Then images are analyzed by using film dose analysis software in SNC Patient 5.2. Results: With focus on the center of active section of source, the position accuracy of this afterloading system with "1"9"2Ir source was -0.75 mm. Using film analysis could make the step point to tell apart if the step distance was 5 mm away by the method of film analysis, but couldnot make it to tell apart if the step distance was 2.5 mm away. The 2.5 mm step distance accuracy could be judged if the distance between the 1"s"t point and the 3"r"d point was 5 mm, then the 2.5 mm step distance could be deemed to no deviation. The 5 mm step distance of this afterloading system had no deviation in continuous 9 step points measured by flushing-free film. The indirect measuring results of the 2.5 mm step distance had no deviation as well. The position accuracy of this afterloading system measured with the flushing-free film accorded with the national standards. Conclusions: The method of measuring the position accuracy and the step distance accuracy of the afterloading system with "1"9"2Ir source by using flushing-free film is technically feasible. (authors)

  2. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  3. 49 CFR 192.1013 - When may an operator deviate from required periodic inspections under this part?

    Science.gov (United States)

    2010-10-01

    ... to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1013 When may an operator...

  4. Calculation of radiation production of high specific activity isotopes 192Ir and 60Co

    International Nuclear Information System (INIS)

    Zhou Quan; Zhong Wenfa; Xu Xiaolin

    1997-01-01

    The high specific activity isotopes: 192 Ir and 60 Co in the high neutron flux reactor are calculated with the method of reactor physics. The results of calculation are analyzed in two aspects: the production of isotopes and the influence to parameters of the reactor, and hence a better case is proposed as a reference to the production

  5. Measurement of the electromagnetic lifetimes of the first four excited states of /sup 192/Pt

    Energy Technology Data Exchange (ETDEWEB)

    Butt, D K; Raoof, M A; Raoof, S A [Birkbeck Coll., London (UK)

    1976-11-01

    Measurements of the electromagnetic lifetimes of the first four excited states of /sup 192/Pt have been made by the self-comparison method using electron-electron coincidences. The partial lifetimes of the gamma transitions involved have been interpreted in terms of the pairing-plus-quadrupole model of Kumar and Baranger.

  6. Testing of electroformed deposited iridium/powder metallurgy rhenium rockets

    Science.gov (United States)

    Reed, Brian D.; Dickerson, Robert

    1996-01-01

    High-temperature, oxidation-resistant chamber materials offer the thermal margin for high performance and extended lifetimes for radiation-cooled rockets. Rhenium (Re) coated with iridium (Ir) allow hours of operation at 2200 C on Earth-storable propellants. One process for manufacturing Ir/Re rocket chambers is the fabrication of Re substrates by powder metallurgy (PM) and the application of Ir coatings by using electroformed deposition (ED). ED Ir coatings, however, have been found to be porous and poorly adherent. The integrity of ED Ir coatings could be improved by densification after the electroforming process. This report summarizes the testing of two 22-N, ED Ir/PM Re rocket chambers that were subjected to post-deposition treatments in an effort to densify the Ir coating. One chamber was vacuum annealed, while the other chamber was subjected to hot isostatic pressure (HIP). The chambers were tested on gaseous oxygen/gaseous hydrogen propellants, at mixture ratios that simulated the oxidizing environments of Earth-storable propellants. ne annealed ED Ir/PM Re chamber was tested for a total of 24 firings and 4.58 hr at a mixture ratio of 4.2. After only 9 firings, the annealed ED Ir coating began to blister and spall upstream of the throat. The blistering and spalling were similar to what had been experienced with unannealed, as-deposited ED Ir coatings. The HIP ED Ir/PM Re chamber was tested for a total of 91 firings and 11.45 hr at mixture ratios of 3.2 and 4.2. The HIP ED Ir coating remained adherent to the Re substrate throughout testing; there were no visible signs of coating degradation. Metallography revealed, however, thinning of the HIP Ir coating and occasional pores in the Re layer upstream of the throat. Pinholes in the Ir coating may have provided a path for oxidation of the Re substrate at these locations. The HIP ED Ir coating proved to be more effective than vacuum annealed and as-deposited ED Ir. Further densification is still required to

  7. Evaluation of Wall Correction Factor of INER's Air-Kerma Primary Standard Chamber and Dose Variation by Source Displacement for HDR 192Ir Brachytherapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2013-01-01

    Full Text Available The aim of the present study was to estimate the wall effect of the self-made spherical graphite-walled cavity chamber with the Monte Carlo method for establishing the air-kerma primary standard of high-dose-rate (HDR 192Ir brachytherapy sources at the Institute of Nuclear Energy Research (INER, Taiwan. The Monte Carlo method established in this paper was also employed to respectively simulate wall correction factors of the 192Ir air-kerma standard chambers used at the National Institute of Standards and Technology (NIST, USA and the National Physical Laboratory (NPL, UK for comparisons and verification. The chamber wall correction calculation results will be incorporated into INER's HDR 192Ir primary standard in the future. For the brachytherapy treatment in the esophagus or in the bronchi, the position of the isotope may have displacement in the cavity. Thus the delivered dose would differ from the prescribed dose in the treatment plan. We also tried assessing dose distribution due to the position displacement of HDR 192Ir brachytherapy source in a phantom with a central cavity by the Monte Carlo method. The calculated results could offer a clinical reference for the brachytherapy within the human organs with cavity.

  8. Dosimetry of iridium-192 sources used in brachytherapy

    International Nuclear Information System (INIS)

    Henn, Keli Cristina

    1999-09-01

    The use of high dose rate brachytherapy (HDR) has been increasing in recent years, due to several advantages relative to conventional low dose rate brachytherapy, such as: shorter treatment times, the ability to fractionate treatment (and thus perform many treatments on an outpatient basis) and reduced worker exposures. Most HDR equipment uses small, high activity 192 Ir sources, which are introduced into the patient using a remote system. The dose distribution around these sources is strongly dependent on the size and shape of the active volume and on the encapsulation of the source. The objective of this work is to compare two methods of calibrating sources of 192 Ir, mamely, measurements in air with an ionization thimble chamber or with a well-type ionization chamber. In addition, we measured the anisotropy of the sources and made comparisons with values supplied by the manufacturer, since this factor is taken into account in the planning system algorithm when dose distributions are calculated. The dose was also evaluated at points of clinical interest (i.e. in the rectum and bladder) and compared to values obtained with the Nucletron PLATO-BPS planning system. The use of lead for rectal protection was evaluated in a cylindrical applicator, aiming the further development of a gynecological applicator. The results of the calibration of seven sources showed that the uncertainty in the calibration in a 'jig' system is smaller than 1%, compared to the value supplied by the source manufacturer. The differences between the results obtained with the well-type ionization camera and the 'jig' system were around 2%. The anisotropy showed good agreement with the values supplied by the manufacturer. The results show that the anisotropy factors, in air and water, are approximately constant and equal to 1.0, for angles between 70 deg and 150 deg. For angles smaller than 70 deg the anisotropy factor in water is larger than in air. Results are also presented for 180 deg, which

  9. Development of the double encapsulated sources of Ir 192 for industrial applications

    International Nuclear Information System (INIS)

    Munoz, C; Sabio Calvete, M; Bianchi, D; Banchik, D; Gonzalez, A; Mender, A

    2004-01-01

    The steps are described that were followed for carrying out the scientific and technological development of the double encapsulated sources for the Iridium-192 to be used in industrial gammagraphy. This development arises from an agreement between INVAP and the CNEA as part of the EGIPTO Project. Each step is outlined in the development together with the different experiences undertaken to obtain the source, whose construction meets the local and international standards for safety and radiological protection (ARN, IRAM, ISO standards) (Cw)

  10. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  11. Dosimetric study of a brachytherapy treatment of esophagus with Brazilian 192Ir sources using an anthropomorphic phantom

    Science.gov (United States)

    Neves, Lucio P.; Santos, William S.; Gorski, Ronan; Perini, Ana P.; Maia, Ana F.; Caldas, Linda V. E.; Orengo, Gilberto

    2014-11-01

    Several radioisotopes are produced at Instituto de Pesquisas Energéticas e Nucleares for the use in medical treatments, including the activation of 192Ir sources. These sources are suitable for brachytherapy treatments, due to their low or high activity, depending on the concentration of 192Ir, easiness to manufacture, small size, stable daughter products and the possibility of re-utilization. They may be used for the treatment of prostate, cervix, head and neck, skin, breast, gallbladder, uterus, vagina, lung, rectum, and eye cancer treatment. In this work, the use of some 192Ir sources was studied for the treatment of esophagus cancer, especially the dose determination of important structures, such as those on the mediastinum. This was carried out utilizing a FASH anthropomorphic phantom and the MCNP5 Monte Carlo code to transport the radiation through matter. It was possible to observe that the doses at lungs, breast, esophagus, thyroid and heart were the highest, which was expected due to their proximity to the source. Therefore, the data are useful to assess the representative dose specific to brachytherapy treatments on the esophagus for radiation protection purposes. The use of brachytherapy sources was studied for the treatment of esophagus cancer. FASH anthropomorphic phantom and MCNP5 Monte Carlo code were employed. The doses at lungs, breast, esophagus, thyroid and heart were the highest. The data is useful to assess the representative doses of treatments on the esophagus.

  12. Descriptive study of 192 adults with speech and language disturbances

    Directory of Open Access Journals (Sweden)

    Letícia Lessa Mansur

    Full Text Available CONTEXT: Aphasia is a very disabling condition caused by neurological diseases. In Brazil, we have little data on the profile of aphasics treated in rehabilitation centers. OBJECTIVE: To present a descriptive study of 192 patients, providing a reference sample of speech and language disturbances among Brazilians. DESIGN: Retrospective study. SETTING: Speech Pathology Unit linked to the Neurology Division of the Hospital das Clínicas of the Faculdade de Medicina da Universidade de São Paulo. SAMPLE: All patients (192 referred to our Speech Pathology service from 1995 to 2000. PROCEDURES: We collected data relating to demographic variables, etiology, language evaluation (functional evaluation, Boston Diagnostic Aphasia Examination, Boston Naming and Token Test, and neuroimaging studies. MAIN MEASUREMENTS: The results obtained in language tests and the clinical and neuroimaging data were organized and classified. Seventy aphasics were chosen for constructing a profile. Fourteen subjects with left single-lobe dysfunction were analyzed in detail. Seventeen aphasics were compared with 17 normal subjects, all performing the Token Test. RESULTS: One hundred subjects (52% were men and 92 (48% women. Their education varied from 0 to 16 years (average: 6.5; standard deviation: 4.53. We identified the lesion sites in 104 patients: 89% in the left hemisphere and 58% due to stroke. The incidence of aphasia was 70%; dysarthria and apraxia, 6%; functional alterations in communication, 17%; and 7% were normal. Statistically significant differences appeared when comparing the subgroup to controls in the Token Test. CONCLUSIONS: We believe that this sample contributes to a better understanding of neurological patients with speech and language disturbances and may be useful as a reference for health professionals involved in the rehabilitation of such disorders.

  13. 49 CFR 192.929 - What are the requirements for using Direct Assessment for Stress Corrosion Cracking (SCCDA)?

    Science.gov (United States)

    2010-10-01

    ... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.929 What are the...

  14. Dosimetry audit on the accuracy of {sup 192}Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in {sup 192}Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an {sup 192}Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the {+-}3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The {sup 192}Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI.

  15. The 257 MeV 19/2/sup -/ two-phonon octupole state in /sup 147/Gd

    CERN Document Server

    Kleinheinz, P; Kortelahti, M; Piiparinen, M; Styczen, J

    1981-01-01

    The half-life of the (vf/sub 7/2/*3/sup -/*3/sup -/)/sub 19/2-/ two- phonon octupole states at 2.572 MeV in /sup 147/Gd was measured as T /sub 1/2/=0.37(8) ns, which gives a transition strength of 52(15) WU for the 1525 keV E3 transition to the 0.997 MeV (vf/sub 7/2/*3/sup -/) /sub 13/2+/ one transition to the 0.997 MeV ( nu f/sub 7/2/*3/sup -/) /sub 13/2+/ one phonon excitation. The nu i/sub 13/2/ admixture in the 13/2/sup +/ one-phonon state, as well as the dominant pi h/sub 11/2/d /sub 5//sup -1/2/ component of the /sup 146/Gd 3/sup -/ state give rise to large anharmonicities for the two-phonon excitation. An estimate of the energy shifts based on empirical coupling matrix elements gives 2.66 MeV excitation for the 19/2/sup -/ two-phonon state, in good agreement with the observed energy of that state. (9 refs).

  16. Chemonuclear studies for identification for new production routes for the therapeutically useful radionuclides {sup 140}Nd, {sup 192}Ir, {sup 191}Pt, {sup 193m}Pt, und {sup 195m}Pt; Kernchemische Studien zur Entwicklung neuerer Produktionsverfahren fuer die therapierelevanten Radionuklide {sup 140}Nd, {sup 192}Ir, {sup 191}Pt, {sup 193m}Pt, und {sup 195m}Pt

    Energy Technology Data Exchange (ETDEWEB)

    Hilgers, K.

    2005-12-15

    New production routes for the therapeutically useful radionuclides {sup 140}Nd, {sup 192}Ir, {sup 191}Pt, {sup 193m}Pt and {sup 195m}Pt were investigated. Cross section data were measured using the stacked-foil technique and compared with theoretical calculations. A production method for the platinum nuclides was developed. The {sup 141}Pr(p, 2n){sup 140}Nd and {sup nat}Ce({sup 3}He, xn){sup 140}Nd reactions were investigated for production of {sup 140}Nd. Cross section data of nuclear reactions leading to the side products {sup 141}Nd, {sup 139}Nd and {sup 139}Ce could also be achieved. The experimental data were compared with theoretical calculations using the code ALICE-IPPE. A comparison of the calculated thick target yields showed that the {sup 141}Pr(p, 2n){sup 140}Nd reaction gives a higher yield. The {sup 192}Os(p, n){sup 192}Ir reaction was examined in the context of the production of {sup 192}Ir. Cross section data were determined and compared with theoretical calculations using the codes ALICE-IPPE and EMPIRE II. The yield of this reaction was compared with the yield of the reactor production of this nuclide. The reactor production seems to be more suitable because of a higher purity and yield. Cross section data were measured for the {sup 192}Os({alpha}, n){sup 195m}Pt, {sup 192}Os({alpha}, 3n){sup 193m}Pt and {sup 192}Os({sup 3}He, 4n){sup 191}Pt reactions. The activity of {sup 193m}Pt and {sup 195m}Pt was determined by X-ray spectroscopy after a chemical separation procedure. The ALICE-IPPE code was found to be inappropriate to reproduce the experimental values. The calculated yields were compared with the yields of other reactions, especially the reactor production of {sup 195m}Pt. The yield of the {sup 192}Os({alpha}, n){sup 195m}Pt reaction is lower compared to the yield of the reactor production, but offers lower target costs and higher specific activity. A production method for {sup 193m}Pt and {sup 195m}Pt was developed. Batch yields of 0.9 MBq

  17. Muscle invasive bladder cancer treated by transurethral resection, followed by external beam radiation and interstitial iridium-192

    NARCIS (Netherlands)

    A. Wijnmaalen (Arendjan); P.A. Helle (Peter); P.C.M. Koper (Peter); P.P. Jansen (Peter); P. Hanssens (Patrick); C.G.G. Boeken Kruger (Cornelis); W.L.J. van Putten (Wim)

    1997-01-01

    textabstractPurpose: To evaluate the results of transurethral resection (TUR), external beam radiotherapy (EBRT), and interstitial radiation (IRT) with iridium-192, using the afterloading technique in patients with muscle invasive bladder cancer. Methods and Materials: From May 1989 until September

  18. 49 CFR 192.913 - When may an operator deviate its program from certain requirements of this subpart?

    Science.gov (United States)

    2010-10-01

    ... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.913 When may an operator deviate its program...

  19. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  20. Dosimetric measurements of an 192Ir HDR source with a diamond detector

    International Nuclear Information System (INIS)

    Rustgi, Surendra N.

    1996-01-01

    Purpose: To study the feasibility of using a diamond detector for the dosimetry of a high dose rate (HDR) 192 Ir source and to compare the measurement results with published data and calculations from a commercial treatment planning system. Materials and methods: The sensitive volume of the diamond detector consists of a disk of 0.26 mm thickness and 3 mm diameter. The detector was applied an external bias of +100 V and was preirradiated to a dose of 500 cGy to stabilize its response. The 192 Ir source from the Nucletron microSelectron unit has an active diameter of 0.6 mm and a length of 3.5 mm. Photon fluence anisotropy factors in air were measured at distances of 5 and 10 cm from two sources and compared with TLD measurements. Dose profiles and isodose distributions were measured at several distances from the source and compared with calculations from a Nucletron treatment planning system. These dose calculations in water use a point source approximation with the anisotropy factors independent of the radial distance from the source. Results: The photon fluence around the 192 Ir HDR source, measured with a diamond detector at distances of 5 and 10 cm from the source, is very anisotropic. Compared to the source transverse direction, the photon fluence intensity along the source axis reduces to approximately 60%. Measurements performed on two sources indicate that the photon anisotropy does not change with distance in air. Within experimental uncertainty, similar results were obtained with TLD rods and are in excellent agreement with published anisotropy factors 1 . Dose profiles, measured with the diamond detector in a water phantom, at distances of 1,2,3 and 5 cm from the source, are found to be in excellent agreement with the Nucletron planning system calculations. Similar excellent agreement is observed between the measured and calculated isodose curves in planes parallel to the source plane. Conclusion: The diamond detector has been demonstrated to be suitable

  1. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  2. Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Sarabiasl, Akbar; Ayoobian, Navid; Jabbari, Iraj; Poorbaygi, Hossein; Javanshir, Mohammad Reza

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR 192 Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h −1 U −1 . The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR 192 Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.

  3. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Konirova, R.; Vecernik, P.; Jedinakova-Krizova, V.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. It is generally known that bentonite materials show an excellent cation-exchange capacity and, on the other hand, a poor uptake of anions. Technetium occurs under aerobic conditions in its most stable oxidation state (+VII) as pertechnetate, which makes a question of its sorption on bentonite more complex when compared with e.g. Cs + or Sr 2+ . To increase the K d values for technetium sorption on bentonite, it is necessary to carry out the experiments under anaerobic conditions in the presence of reducing agent, which is capable to lower the oxidation state of technetium which enables its successful immobilization. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing conditions. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ , Fe) with bentonite, the effect of solid:aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. (authors)

  4. 49 CFR 192.917 - How does an operator identify potential threats to pipeline integrity and use the threat...

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192...

  5. 49 CFR 192.915 - What knowledge and training must personnel have to carry out an integrity management program?

    Science.gov (United States)

    2010-10-01

    ... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.915 What knowledge...

  6. 49 CFR 192.7 - What documents are incorporated by reference partly or wholly in this part?

    Science.gov (United States)

    2010-10-01

    ... “Recommended Practice 1165 “Recommended Practice for Pipeline SCADA Displays,” (API RP 1165) (First edition..., effective March 1, 1997) § 192.65(b). (4) ANSI/API Specification 6D, “Specification for Pipeline Valves..., Appendix B. (7) API Recommended Practice 1162, “Public Awareness Programs for Pipeline Operators,” (1st...

  7. Studies on 192Ir afterloading irradiation of the canine prostate with special consideration of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Reuter, M.

    1986-01-01

    A method for high dose rate afterloading irradiation of the prostate with iridium 192 was developed. The isodoses of the urethra and rectum, which were measured by means of thermoluminescent dosimetry, showed deviations from the doses pre-calculated by computer (BRACHY), because this calculation is based on an anatomically ideal condition. (MBC) [de

  8. Comparative study of the anchorage and the catalytic properties of nanoporous TiO2 films modified with ruthenium (II) and rhenium (I) carbonyl complexes

    Science.gov (United States)

    Oyarzún, Diego P.; Chardon-Noblat, Sylvie; Linarez Pérez, Omar E.; López Teijelo, Manuel; Zúñiga, César; Zarate, Ximena; Shott, Eduardo; Carreño, Alexander; Arratia-Perez, Ramiro

    2018-02-01

    In this article we study the anchoring of cis-[Ru(bpyC4pyr)(CO)2(CH3CN)2]2+, cis-[Ru(bpy)2(CO)2]2+ and cis-[Ru(bpyac)(CO)2Cl2], onto nanoporous TiO2 employing electropolymerization, electrostatic interaction and chemical bonding. Also, the [Re(bpyac)(CO)3Cl] rhenium(I) complex for chemical anchorage was analyzed. The characterization of TiO2/Ru(II) and TiO2/Re(I) nanocomposite films was performed by field emission scanning electron microscopy (FESEM), electron dispersive X-ray spectroscopy (EDS) and Raman spectroscopy. In addition, for the more stable nanocomposites obtained, the catalytic properties (solar energy conversion and CO2 reduction) were evaluated. The efficiency improvement in redox process derived from the (photo)electrochemical evidence indicates that modified nanoporous TiO2 structures enhance the rate of charge transfer reactions.

  9. Rotavirus 2/6 Viruslike Particles Administered Intranasally with Cholera Toxin, Escherichia coli Heat-Labile Toxin (LT), and LT-R192G Induce Protection from Rotavirus Challenge

    Science.gov (United States)

    O’Neal, Christine M.; Clements, John D.; Estes, Mary K.; Conner, Margaret E.

    1998-01-01

    We have shown that rotavirus 2/6 viruslike particles composed of proteins VP2 and VP6 (2/6-VLPs) administered to mice intranasally with cholera toxin (CT) induced protection from rotavirus challenge, as measured by virus shedding. Since it is unclear if CT will be approved for human use, we evaluated the adjuvanticity of Escherichia coli heat-labile toxin (LT) and LT-R192G. Mice were inoculated intranasally with 10 μg of 2/6-VLPs combined with CT, LT, or LT-R192G. All three adjuvants induced equivalent geometric mean titers of rotavirus-specific serum antibody and intestinal immunoglobulin G (IgG). Mice inoculated with 2/6-VLPs with LT produced significantly higher titers of intestinal IgA than mice given CT as the adjuvant. All mice inoculated with 2/6-VLPs mixed with LT and LT-R192G were totally protected (100%) from rotavirus challenge, while mice inoculated with 2/6-VLPs mixed with CT showed a mean 91% protection from challenge. The availability of a safe, effective mucosal adjuvant such as LT-R192G will increase the practicality of administering recombinant vaccines mucosally. PMID:9525668

  10. Interstitial brachytherapy with 192-IR in treatment of recurrent malignant primary brain tumors. Braquiterapia intersticial con iridio-192 en el tratamiento de recidivas de tumores cerebrales tras cirugia y radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Cardenes, R.; Martinez, R.; Victoria, C.; Nuez, L.; Clavo, B.; Sancedo, G. (Clinica Puerta de Hierro. Madrid (Spain))

    1994-01-01

    Seven patients with recurrent malignant primary brain tumors after surgery and radiation therapy were treated at the Clinica Puerta de Hierro (Madrid) by interstitial brachytherapy with 192-Ir sources. Implantations were performed using computerized tomography and dose prescription were determined following the Paris system rules for interstitial implants. The means dose deliberated was 50 to 65 Gy to the reference isodoses. At the last follow-up all patients except for one are alive and without evidence of progression of the disease. (Author) 35 refs.

  11. Lifetimes of an excited superdeformed band in {sup 192}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Blumenthal, D.; Carpenter, M.P. [and others

    1995-08-01

    An excited superdeformed band was identified in {sup 192}Hg and the lifetimes of its levels measured with the Doppler-shift attenuation method from data taken with the Eurogam spectrometer. The band is proposed to be based on the two-quasineutron (v[642]3/2 [512]5/2) configuration, which after a band crossing, becomes the (v[642]3/2 [752]5/2) configuration. The transition quadrupole moment Q{sub t} of the excited band is the same as that of the yrast SD band, within experimental errors. This suggests that the deformation of the SD minimum is robust with respect to quasiparticle excitation, despite the occupation of the deformation-driving v[752]5/2 level (from the j{sub 15/2} shell) after the band crossing.

  12. 49 CFR 192.937 - What is a continual process of evaluation and assessment to maintain a pipeline's integrity?

    Science.gov (United States)

    2010-10-01

    ... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.937 What is a...

  13. Novel Approaches to Extraction Methods in Recovery of Capsaicin from Habanero Pepper (CNPH 15.192).

    Science.gov (United States)

    Martins, Frederico S; Borges, Leonardo L; Ribeiro, Claudia S C; Reifschneider, Francisco J B; Conceição, Edemilson C

    2017-07-01

    The objective of this study was to compare three capsaicin extraction methods: Shoxlet, Ultrasound-assisted Extraction (UAE), and Shaker-assisted Extraction (SAE) from Habanero pepper, CNPH 15.192. The different parameters evaluated were alcohol degree, time extraction, and solid-solvent ratio using response surface methodology (RSM). The three parameters found significant ( p Soxhlet increased the extraction in 10-25%; however, long extraction times (45 minutes) degraded 2% capsaicin. The extraction of capsaicin was influenced by extraction method and by the operating conditions chosen. The optimized conditions provided savings of time, solvent, and herbal material. Prudent choice of the extraction method is essential to ensure optimal yield of extract, thereby making the study relevant and the knowledge gained useful for further exploitation and application of this resource. Habanero pepper , line CNPH 15.192, possess capsaicin in higher levels when compared with others speciesHigher levels of ethanolic strength are more suitable to obtain a higher levels of capsaicinBox-Behnken design indicates to be useful to explore the best conditions of ultrasound assisted extraction of capsaicin. Abbreviations used: Nomenclature UAE: Ultrasound-assisted Extraction; SAE: Shaker-assisted Extraction.

  14. Residency of rhenium and osmium in a heavy crude oil

    Science.gov (United States)

    DiMarzio, Jenna M.; Georgiev, Svetoslav V.; Stein, Holly J.; Hannah, Judith L.

    2018-01-01

    Rhenium-osmium (Re-Os) isotope geochemistry is an emerging tool for the study of oil formation and migration processes, and a new technology for petroleum exploration. Little is known, however, about the residency of Re and Os within asphaltene and maltene sub-fractions of crude oil. This information is crucial for understanding the 187Re-187Os radiometric clock held in petroleum systems and for interpreting geochronology for key processes such as oil formation, migration, and biodegradation. In this study, a heavy crude oil was separated into soluble (maltene, MALT) and insoluble (asphaltene, ASPH) fractions using n-heptane as the asphaltene-precipitating agent. The asphaltenes were separated sequentially into sub-fractions using two different solvent pairs (heptane-dichloromethane and acetone-toluene), and the bulk maltenes were separated into saturate, aromatic, and resin (SAR) fractions using open column chromatography. Each asphaltene and maltene sub-fraction was analyzed for Re and Os. The asphaltene sub-fractions and the bulk ASPH, MALT, and crude oil were analyzed for a suite of trace metals by ICP-MS. Our results show that Re and Os concentrations co-vary between the asphaltene sub-fractions, and that both elements are found mostly in the more polar and aromatic sub-fractions. Significant Re and Os are also present in the aromatic and resin fractions of the maltenes. However, each asphaltene and maltene sub-fraction has a distinct isotopic composition, and sub-fractions are not isochronous. This suggests that asphaltene sub-fractionation separates Re-Os complexes to the point where the isotopic integrity of the geochronometer is compromised. The mobility of individual Re and Os isotopes and the decoupling possibilities between radiogenic 187Os produced from 187Re remain elusive, but their recognition in this study is a critical first step. Re and Os correlate strongly with Mo and Cd in the asphaltene sub-fractions, suggesting that these metals occupy

  15. Fabrication of Tungsten-Rhenium Cladding materials via Spark Plasma Sintering for Ultra High Temperature Reactor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Charit, Indrajit; Butt, Darryl; Frary, Megan; Carroll, Mark

    2012-11-05

    This research will develop an optimized, cost-effective method for producing high-purity tungsten-rhenium alloyed fuel clad forms that are crucial for the development of a very high-temperature nuclear reactor. The study will provide critical insight into the fundamental behavior (processing-microstructure- property correlations) of W-Re alloys made using this new fabrication process comprising high-energy ball milling (HEBM) and spark plasma sintering (SPS). A broader goal is to re-establish the U.S. lead in the research field of refractory alloys, such as W-Re systems, with potential applications in very high-temperature nuclear reactors. An essential long-term goal for nuclear power is to develop the capability of operating nuclear reactors at temperatures in excess of 1,000K. This capability has applications in space exploration and some special terrestrial uses where high temperatures are needed in certain chemical or reforming processes. Refractory alloys have been identified as being capable of withstanding temperatures in excess of 1,000K and are considered critical for the development of ultra hightemperature reactors. Tungsten alloys are known to possess extraordinary properties, such as excellent high-temperature capability, including the ability to resist leakage of fissile materials when used as a fuel clad. However, there are difficulties with the development of refractory alloys: 1) lack of basic experimental data on thermodynamics and mechanical and physical properties, and 2) challenges associated with processing these alloys.

  16. Dissimilar behavior of technetium and rhenium in borosilicatewaste glass as determined by X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lukens, Wayne W.; McKeown, David A.; Buechele, Andrew C.; Muller,Isabelle S.; Shuh, David K.; Pegg, Ian L.

    2006-11-09

    Technetium-99 is an abundant, long-lived (t1/2 = 213,000 yr)fission product that creates challenges for the safe, long-term disposalof nuclear waste. While 99Tc receives attention largely due to its highenvironmental mobility, it also causes problems during its incorporationinto nuclear waste glass due to the volatility of Tc(VII) compounds. Thisvolatility decreases the amount of 99Tc stabilized in the waste glass andcauses contamination of the waste glass melter and off-gas system. Theapproach to decrease the volatility of 99Tc that has received the mostattention is reduction of the volatile Tc(VII) species to less volatileTc(IV) species in the glass melt. On engineering scale experiments,rhenium is often used as a non-radioactive surrogate for 99Tc to avoidthe radioactive contamination problems caused by volatile 99Tc compounds.However, Re(VII) is more stable towards reduction than Tc(VII), so morereducing conditions would be required in the glass melt to produceRe(IV). To better understand the redox behavior of Tc and Re in nuclearwaste glass, a series of glasses were prepared under different redoxconditions. The speciation of Tc and Re in the resulting glasses wasdetermined by X-ray absorption fine structure spectroscopy. Surprisingly,Re and Tc do not behave similarly in the glass melt. Although Tc(0),Tc(IV), and Tc(VII) were observed in these samples, only Re(0) andRe(VII) were found. In no case was Re(IV) (or Re(VI))observed.

  17. Interstitial brachytherapy with 192-IR in treatment of recurrent malignant primary brain tumors

    International Nuclear Information System (INIS)

    Cardenes, R.; Martinez, R.; Victoria, C.; Nunez, L.; Clavo, B.; Sancedo, G.

    1994-01-01

    Seven patients with recurrent malignant primary brain tumors after surgery and radiation therapy were treated at the Clinica Puerta de Hierro (Madrid) by interstitial brachytherapy with 192-Ir sources. Implantations were performed using computerized tomography and dose prescription were determined following the Paris system rules for interstitial implants. The means dose deliberated was 50 to 65 Gy to the reference isodoses. At the last follow-up all patients except for one are alive and without evidence of progression of the disease. (Author) 35 refs

  18. Development of the doubly sealed Ir192 sources for industrial applications

    International Nuclear Information System (INIS)

    Munoz, C.; Sabio Calvett, Manuel; Bianchi, Daniel R.; Banchik, Abraham D.; Mender, Alberto; Gonzalez, Alfredo J.

    2003-01-01

    A Program for Developing Double Sealed Irradiation Sources for industrial and medical applications is in progress at the Argentine Atomic Energy Commission. The present work describes the mechanical and metallurgical procedures for designing and welding dummy capsules of the two types that are required for making double sealed Ir 192 industrial sources with the designation ISO/98/C43515 according to ISO 2919 and leak tight according to ISO/98/9978 standards. That is part of a Project with INVAP company. Four different models, including the typical international model, were designed, machined and TIG-welded. Both the internal and external capsules and the end caps were made from AISI 316L stainless steel. Two types of welding station were made. In the first one the 'end cap' was welded to the capsule keeping the torch and the capsule fixed (stationary process), while in the second type the capsule rotates around its own axes during the process (out of cell dynamic semiautomatic controlled process). The welding parameters for the second welding process were selected from the different parameters used to process 120 'international type' capsules. All the processed units were subject to a visual inspection, 85% of them were considered acceptable, while the rest were rejected because of having, at naked eyes and/or under magnification glasses, different types of welding defects. Metallographic examination of the microstructure at the welding seam and the matrix were made in welded unit selected at random from different lots of all processed units in order to determine the penetration of the weld and the microstructure of the weld seam. Present results are encouraging enough to consider to start with the next step, where the capsules are process inside a 'hot cell' and with a Ir 192 foil inside the inner capsule to reproduce actual fabrication conditions. (author)

  19. Human Paraoxonase1 Hydrolysis of Nanomolar Chlorpyrifos-oxon Concentrations is Unaffected by Phenotype or Q192R Genotype

    Science.gov (United States)

    Coombes, R. Hunter; Meek, Edward C.; Dail, Mary Beth; Chambers, Howard W.; Chambers, Janice E.

    2016-01-01

    The organophosphorus insecticide chlorpyrifos has been widely used. Its active metabolite chlorpyrifos-oxon (CPO) is a potent anticholinesterase and is detoxified by paraoxonase-1 (PON1). PON1 activity is influenced by numerous factors including a Q192R polymorphism. Using forty human blood samples bearing homozygous genotypes and either high or low activity phenotypes (as determined by high concentration assays of paraoxon and diazoxon hydrolysis) the serum PON1 hydrolysis of high (320 μM) and low (178 nM) CPO concentrations was assessed using direct or indirect spectrophotometric methods, respectively. PON1 activity at high CPO concentration reflected the phenotype and genotype differences; subjects with the high activity phenotype and homozygous for the PON1R192 alloform hydrolyzed significantly more CPO than subjects with the low activity phenotype and/or PON1Q192 alloform (High RR=11023±722, Low RR=9467±798, High QQ=8809±672, Low QQ=6030±1015 μmoles CPO hydrolyzed/min/L serum). However, PON1 hydrolysis of CPO at the lower, more environmentally relevant concentration showed no significant differences between the PON1192 genotypes and/or between high and low activity phenotypes (High RR=231±27, Low RR=219±52, High QQ=193±59, Low QQ=185±43 nmoles CPO/min/L serum). Low CPO concentrations were probably not saturating, so PON1 did not display maximal velocity and the PON1 genotype/phenotype might not influence the extent of metabolism at environmental exposures. PMID:25093614

  20. Influence of the 192Ir source decay on biological effect

    International Nuclear Information System (INIS)

    Wang Shunbao; Feng Ningyuan; Niu Wenzhe; Yang Yuhui; Guo Lei

    1994-01-01

    Biological effect of the 192 Ir high activity source on LA 795 tumor of mice and HCT-8 cells have been investigated when decay of the source power from 340.4 GBq to 81.4 GBq no marked difference was found between the two cell survival curves of HCT-8 cells and both of them compared with that of the X-ray irradiation the value of relative biological effect (0.1 survival) was 0.43. On the experiment of tumor LA 795 of mice, when the source power was 293.3 GBq and 96.2 GBq, no different biological effect can be seen between the two series of figures. The relative biological effect was 0.55-0.60 (tumor growth delay) comparing with those of X-ray irradiation

  1. 192Ir high dose rate (HDR) interstitial brain implant: optimisation

    International Nuclear Information System (INIS)

    Tyagi, Anuj; Singh, Dinesh; Chitra, S.; Gupta, J.P.

    2001-01-01

    The new modality of stepping source dosimetry system (SSDs) illustrates a remarkable improvement in attaining the uniform and homogeneous dose distribution within the target volume. The technique enables the physicist to correct for a certain amount of misplacement or curvature of implant geometry. The short course of brachytherapy provides good palliation in terms of functional improvements with low and acceptable toxicity in high-grade glioma. With continual refinements of the technique, brachytherapy performed by a skilled brachytherapy team offers an opportunity to improve patient survival and quality of life. Since 1997, micro selectron HDR 192 Ir treatments are done including gynecological, oesophageal, breast, surface mould, soft tissue sarcoma (STS) and brain in our hospital. In this paper, procedure of interstitial brain implant in glioma as implant technique, simulation and treatment planning will be discussed

  2. 192Ir Preservation, radiation protection and its application in the Hermanos Ameijeiras Hospital

    International Nuclear Information System (INIS)

    Perez Guevara, A.; Leonard Valhuerdi, M.; Silvestre Patallo, I.; Bernal Rodriguez, M.; Gonzalez Quintana, J.

    1996-01-01

    Since the beginning of 1990 the first steps were taken in our Hospital for the use of the 192I r radioisotope in the treatment of malignant tumors. In order to use this radioisotope it has been necessary tomanufacture different instruments to manipulate it as the building the place for its storage preservation and preparation ( HOT ROOM). The radiation protection prerequisites established by standards and decrees issued were taken into account for the design and construction thus allowing to obtain the license granted by the Regulations Organization (Centro Nacional de Seguridad Nuclear)

  3. Influence on serum asymmetric dimethylarginine (ADMA) concentrations of human paraoxonase 1 polymorphism (Q192R) and exposure to polycyclic aromatic hydrocarbons (PAHs) in Mexican women, a gene-environment interaction.

    Science.gov (United States)

    Ochoa-Martínez, Ángeles C; Ruíz-Vera, Tania; Almendarez-Reyna, Claudia I; Orta-García, Sandra T; Pérez-Maldonado, Iván N

    2017-11-01

    It has been demonstrated that Cardiovascular Diseases (CVD) are a consequence of the combination of genetic and environmental factors and/or the interaction between them. Therefore, the aim of this study was to evaluate the impact of polycyclic aromatic hydrocarbon (PAHs) exposure and PON1 Q192R polymorphism (genetic susceptibility) on serum asymmetric dimethylarginine (ADMA) levels in Mexican women (n = 206). Urinary 1-hydroxypyrene concentrations (1-OHP; exposure biomarker for PAHs) were quantified using a high-performance liquid chromatography technique, PON1 Q192R polymorphism was genotyped using TaqMan probes and serum ADMA concentrations were evaluated using a commercially available ELISA kit. Urinary 1-OHP levels detected in this study ranged from 0.07 to 9.37 μmol/mol of creatinine (0.13-18.0 μg/g of creatinine). Regarding allele frequency (PON1 Q192R polymorphism), the 192Q-allele frequency was 0.43 and for the 192R-allele it was 0.57. In relation to serum ADMA levels, the levels ranged from 0.06 to 1.46 μmol/L. Moreover, multiple linear regression analysis was performed and associations between urinary 1-OHP levels (β = 0.05, p = 0.002), PON1 Q192R polymorphism (β = 0.04, p = 0.003) and serum ADMA concentrations were found. Besides, an interaction (gene-environment interaction) of both independent variables (1-OHP and PON1 polymorphism) on serum ADMA levels was found (β = 0.04, p = 0.02) in the constructed multiple linear model. Therefore, according to the significance of this research, it is necessary to execute health programs to reduce cardiovascular risk in the assessed population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Electronic structures and properties of the rhenium alkoxy derivatives Re2O3(OMe)6, Re4O6(OMe)12, and ReMoO2(OMe)7

    International Nuclear Information System (INIS)

    Ermakov, A.I.; Belousov, V.V.; Drobot, D.V.; Shcheglov, P.A.

    2006-01-01

    The geometrical structures, charge distributions, dipole moments, frequencies of normal vibrations, NMR spectra, and total energies of the chemical bonds for the rhenium alkoxy derivatives Re 2 O 3 (OMe) 6 , Re 4 O 6 (OMe) 12 , and ReMoO 2 (OMe) 7 were calculated by the DFT-B3LYP and Hartree-Fock ab initio methods based on the effective core potential theory (LANL2DZ approximation) and the semiempirical PM3(tm) method. Two optimized structures of Re 2 O 3 (OMe) 6 with close energies were found to substantially differ in geometry, 1 H, 13 C, and 17 O NMR spectra, and dipole moment. Various characteristics of the electronic structures and the trans-effect of the ligands in the compounds under consideration were discussed [ru

  5. Intercomparison of calibration procedures of high dose rate 192 Ir sources in Brazil and a proposal of a new methodology

    International Nuclear Information System (INIS)

    Marechal, M.H.; Almeida, C.E. de

    1998-01-01

    The objective of this paper is to report the results of an intercomparison of the calibration procedures for 192 Ir sources presently in use in Brazil and to proposal a calibration procedure to derive the N k for a Farmer type ionization chamber for 192 Ir energy by interpolating from a 60 Co gamma-rays and 250 kV x-rays calibration factors. the intercomparison results were all within ± 3.0 % except one case where 4.6 % was observed and latter identified as a problem with N-k value for X-rays. The method proposed by the present work make possible the improvement of the metrological coherence among the calibration laboratories and their users once the N k values could then provided by any of the members of SSDL network. (Author)

  6. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  7. Radioactivity measurements of metallic 192Ir sources by calorimetric methods

    International Nuclear Information System (INIS)

    Genka, Tsuguo; Iwamoto, Seikichi; Takeuchi, Norio

    1992-01-01

    The necessity of establishing the traceability of dose measurement in brachytherapy 192 Ir sources is realized by physicians and researchers in the medical field. Standard sources of various shapes such as open-quotes hairpin,close quotes open-quotes single pin,close quotes open-quotes thin wire,close quotes and open-quotes seedclose quotes for calibrating ionization chambers in hospitals are being demanded. Nominal activities of not only these source products but also the standard sources have been so far specified by open-quotes apparentclose quotes values. Determination of open-quotes absoluteclose quotes activity by an established means such as 4pi-beta-gamma coincidence counting is not practical because quantitative dissolution of metallic iridium is very difficult. We tried to determine the open-quotes absoluteclose quotes activity by a calorimetric method in a fully nondestructive way

  8. Estimation of distance error by fuzzy set theory required for strength determination of HDR (192)Ir brachytherapy sources.

    Science.gov (United States)

    Kumar, Sudhir; Datta, D; Sharma, S D; Chourasiya, G; Babu, D A R; Sharma, D N

    2014-04-01

    Verification of the strength of high dose rate (HDR) (192)Ir brachytherapy sources on receipt from the vendor is an important component of institutional quality assurance program. Either reference air-kerma rate (RAKR) or air-kerma strength (AKS) is the recommended quantity to specify the strength of gamma-emitting brachytherapy sources. The use of Farmer-type cylindrical ionization chamber of sensitive volume 0.6 cm(3) is one of the recommended methods for measuring RAKR of HDR (192)Ir brachytherapy sources. While using the cylindrical chamber method, it is required to determine the positioning error of the ionization chamber with respect to the source which is called the distance error. An attempt has been made to apply the fuzzy set theory to estimate the subjective uncertainty associated with the distance error. A simplified approach of applying this fuzzy set theory has been proposed in the quantification of uncertainty associated with the distance error. In order to express the uncertainty in the framework of fuzzy sets, the uncertainty index was estimated and was found to be within 2.5%, which further indicates that the possibility of error in measuring such distance may be of this order. It is observed that the relative distance li estimated by analytical method and fuzzy set theoretic approach are consistent with each other. The crisp values of li estimated using analytical method lie within the bounds computed using fuzzy set theory. This indicates that li values estimated using analytical methods are within 2.5% uncertainty. This value of uncertainty in distance measurement should be incorporated in the uncertainty budget, while estimating the expanded uncertainty in HDR (192)Ir source strength measurement.

  9. Intercomparison of calibration procedures of high dose rate {sup 192} Ir sources in Brazil and a proposal of a new methodology; Intercomparacao de procedimientos de calibracao de fontes de {sup 192} Ir de alta taxa de dose no Brasil e proposta de uma nova metodologia

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M.H.; Almeida, C.E. de [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes IRD/CNEN. Caixa Postal 37750 CEP 22780-160 Rio de Janeiro (Brazil)

    1998-12-31

    The objective of this paper is to report the results of an intercomparison of the calibration procedures for {sup 192} Ir sources presently in use in Brazil and to proposal a calibration procedure to derive the N{sub k} for a Farmer type ionization chamber for {sup 192} Ir energy by interpolating from a {sup 60} Co gamma-rays and 250 kV x-rays calibration factors. the intercomparison results were all within {+-} 3.0 % except one case where 4.6 % was observed and latter identified as a problem with N-k value for X-rays. The method proposed by the present work make possible the improvement of the metrological coherence among the calibration laboratories and their users once the N{sub k} values could then provided by any of the members of SSDL network. (Author)

  10. Evaluation of radiation dose on people adjacent to implant patients during brachytherapy for prostate cancer using {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Ko, Seong Jin; Kang, Se Sik; Kim, Chang Soo [Catholic University, Busan (Korea, Republic of)

    2009-10-15

    The incidence of prostate cancer is rapidly increasing due to aging of the population and westernization of dietary habits, etc. As a result, the frequency of prostate cancer has become the fifth highest among all male cancers and the first among urological cancers. Brachytherapy is commonly used for locally progressing prostate cancers. Since the mid 1980s, therapies using radio-isotopes, such as low-invasive {sup 125}I, {sup 103}Pd and {sup 192}Ir, have been widely performed in the U.S. and Europe. However, brachytherapy involves implanting radio-isotopes into the human body which is of concern because it may expose the health care professionals administering the therapy to unnecessary radiation. Accordingly, this study intends to predict the radiation dose that people adjacent to patients implanted with a radio-isotope are exposed to during prostate cancer radiation therapy by using a mathematical anthropomorphic phantom and {sup 192}Ir.

  11. Determination of rhenium content in molybdenite by ICP-MS after separation of the major matrix by solvent extraction with N-benzoyl-N-phenylhydroxalamine.

    Science.gov (United States)

    Li, Jie; Zhong, Li-feng; Tu, Xiang-lin; Liang, Xi-rong; Xu, Ji-feng

    2010-05-15

    A simple and rapid analytical method for determining the concentration of rhenium in molybdenite for Re-Os dating was developed. The method used isotope dilution-inductively coupled plasma-mass spectrometry (ID-ICP-MS) after the removal of major matrix elements (e.g., Mo, Fe, and W) from Re by solvent extraction with N-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform solution. The effect on extraction efficiency of parameters such as pH (HCl concentration), BPHA concentration, and extraction time were also assessed. Under the optimal experimental conditions, the validity of the separation method was accessed by measuring (187)Re/(185)Re values for a molybdenite reference material (JDC). The obtained values were in good agreement with previously measured values of the Re standard. The proposed method was applied to replicate Re-Os dating of JDC and seven samples of molybdenite from the Yuanzhuding large Cu-Mo porphyry deposit. The results demonstrate good precision and accuracy for the proposed method. The advantages of the method (i.e., simplicity, efficiency, short analysis time, and low cost) make it suitable for routine analysis.

  12. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology

    International Nuclear Information System (INIS)

    Desbouis, D.

    2007-01-01

    cell uptake in transfected cancer cells this technetium thymidine complex revealed a low internalisation of 0.03 ± 0.01%ID/(mg/mL). Under the same conditions the [ 3 H]thymidine exhibited an uptake of 1.50 ± 0.02%lD/(mg/mL). In order to gain potency and selectivity for HSV1-TK, the corresponding 5'-carboxamide 5-ethyl-2', 5'-dideoxyuridine was synthesized. The synthesis of the ligand was performed in seven steps from 2'-deoxyuridine. This ligand was then successfully labelled with the fac-M(CO) 3 -core (M = 99m Tc, Re). The rhenium complex was found to be a selective competitive inhibitor of HSV1-TK (K i = 4.56 ± 0.11 μM). Although the cellular uptake of the technetium 2'-deoxyurine complex (0.10 ± 0.01%ID/(mg/mL)) was better than its corresponding technetium thymidine complex, it is still very low compared to thymidine uptake. The second aspect of this work was to develop nucleoside derivatives labelled with technetium-99m/rhenium tricarbonyl core capable of acting as substrates for human cytosolic thymidine kinase (hTKl). hTKl is a target of choice to evaluate cell proliferation due to its overexpression in a variety of cancer cells. [ 18 F]Fluorothymidine [ 18 F]FLT), which acts as a hTKl substrate, has emerged as a very efficient PET tracer for the monitoring of cell proliferation. Our aim was to develop a SPET tracer with the same mode of action as [ 18 F]FLT. We prepared a set of technetium-99m/rhenium complexes of N3 thymidine derivatives with different overall charges (+1, 0 and -1) and variable spacer lengths. The complexes with different overall charges had the same spacer length between chelating system and thymidine moiety (two carbons spacer) while the complexes with different spacer lengths (2, 3, 5 and 10) were all neutral. These compounds were tested for their substrate activity with respect to recombinant hTKl. The phosphorylation rates of neutral and negative complexes were found to be similar, ranging between 15-16% with respect to thymidine

  13. Zambia's participation in past CTBTO activities and the upgrading of AS119 and N192: Experiences and the way forward

    International Nuclear Information System (INIS)

    Lombe, D.K.

    2002-01-01

    This presentation briefly describes the Zambian Seisimic Network (ZSN), Zambia's participation in past CTBTO activities and upgrading of AS119 and N192. It goes on to describe various experiences encountered and makes some suggestions for future considerations

  14. Preliminary results of transarterial Rhenium-188 HDD Lipiodol in treatment of inoperable primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sundram, Felix

    2004-01-01

    Full text: In this paper we present our early experience with a new radio-conjugate, namely rhenium-188 HDD Lipiodol (Re-188 lipiodol). Imported radiopharmaceuticals are generally expensive, particularly for developing countries. A Tungsten (W-188-Re 188) generator obtained from ORNL (Oak Ridge National Laboratory, Tennessee, USA) allows us on-site production of a beta emitting therapeutic isotope (Re-188) for up to 6 months from a single generator. The objectives of this study were to establish the safety of trans-arterial Re-188 lipiodol in patients with inoperable HCC, and determine the adverse effects and efficacy for this radio-conjugate treatment in a multi-center study of patients with advanced HCC. A multi-center study was sponsored by the International Atomic Energy Agency (Vienna) to assess the safety and efficacy of trans-arterial Re-188 HDD conjugated lipiodol (radio-conjugate) in the treatment of patients with inoperable hepatocellular carcinoma (HCC), The radio-conjugate was prepared by using a HDD (4-hexadecyl 1-2, 9, 9-tetramethyl-4, 7-diaza-1, 10-decanethiol) kit developed in Korea, and lipiodol. Over a period of eighteen months seventy patients received at least one treatment of radio-conjugate. Some patients were re-treated if there was no evidence of disease progression. The level of radio-conjugate administered was based on radiation-absorbed dose to critical normal organs, calculated following a 'scout' dose of radio-conjugate. The organs at greatest risk for radiation toxicity are the normal liver, the lung and the bone marrow. A specially designed spreadsheet was used to determine maximum tolerated activity (MTA), defined as the amount of radioactivity calculated to deliver no more than 12 Gray (Gy) to lungs, or 30 Gy to liver, or 1.5 Gy to bone marrow. These doses have been found to be safe in multiple trials using external beam therapy and systemically administered radiopharmaceuticals. Patients were followed for at least twelve weeks

  15. HDR 192Ir source speed measurements using a high speed video camera

    International Nuclear Information System (INIS)

    Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio; Podesta, Mark; Rubo, Rodrigo A.; Sales, Camila P. de; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Purpose: The dose delivered with a HDR 192 Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a 192 Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases

  16. 49 CFR 192.1015 - What must a master meter or small liquefied petroleum gas (LPG) operator do to implement this...

    Science.gov (United States)

    2010-10-01

    ... Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1015 What must...

  17. Fungal endocarditis in paediatrics: a review of 192 cases (1971-2016).

    Science.gov (United States)

    Ganesan, Vithiya; Ponnusamy, Shunmuga Sundaram; Sundaramurthy, Raja

    2017-10-01

    The aims of this article were to review the published literature on fungal endocarditis in children and to discuss the aetiology and diagnosis, with emphasis on non-invasive methods and various treatment regimes. We systematically reviewed published cases and case series of fungal endocarditis in children. We searched the literature, including PubMed and individual references for publications of original articles, single cases, or case series of paediatric fungal endocarditis, with the following keywords: "fungal endocarditis", "neonates", "infants", "child", and "cardiac vegetation". There have been 192 documented cases of fungal endocarditis in paediatrics. The highest number of cases was reported in infants (93/192, 48%) including 60 in neonates. Of the neonatal cases, 57 were premature with a median gestational age of 27 weeks and median birth weight of 860 g. Overall, 120 yeast - fungus that grows as a single cell - infections and 43 mould - fungus that grows in multicellular filaments, hyphae - infections were reported. With increasing age, there was an increased infection rate with moulds. All the yeast infections were detected by blood culture. In cases with mould infection, diagnosis was mainly established by culture or histology of emboli or infected valves after invasive surgical procedures. There have been a few recent cases of successful early diagnosis by non-invasive methods such as blood polymerase chain reaction (PCR) for moulds. The overall mortality for paediatric fungal endocarditis was 56.25%. The most important cause of death was cardiac complications due to heart failure. Among the various treatment regimens used, none of them was significantly associated with better outcome. Non-invasive methods such as PCR tests can be used to improve the chances of detecting and identifying the aetiological agent in a timely manner. Delays in the diagnosis of these infections may result in high mortality and morbidity. No significant difference was noted

  18. Gyromagnetic ratios of low-lying excited states in the even 192-198Pt isotopes; experimental measurements and theoretical predictions

    International Nuclear Information System (INIS)

    Stuchbery, A.E.; Ryan, C.G.; Morrison, I.; Bolotin, H.H.

    1981-01-01

    The gyromagnetic ratios of the 2 2 + and 4 1 + states in 196 Pt were measured relative to that of its 2 1 + level. The thin-foil IMPAC technique was employed utilizing the enhanced transient hyperfine magnetic field present at the nuclei of swiftly recoiling ions traversing magnetized ferromagetic materials. The states of interest were populated by Coulomb excitation using beams of 220-MeV 58 Ni ions. For g(2 1 + ) taken as 0.326+-0.014, the present measurements yielded g(2 2 + ) = 0.30+-0.06 and g(4 1 + ) 0.30+-0.05. These results and those reported by prior workers for the g-factors of corresponding levels in 192 Pt, 194 Pt, 198 Pt are used to trace the systematics of the magnetic moments of these low-lying levels in the even 192 - 198 Pt isotopes. Interacting Boson Approximation model-based calculations of the g-factors of these states were also carried out. The experimental theoretical results are compared

  19. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    International Nuclear Information System (INIS)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J.

    2008-12-01

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials

  20. Oncologic and functional outcome of base of tongue cancer treated with external-beam radiation and I-192 implant

    International Nuclear Information System (INIS)

    Harrison, L.B.; Sessions, R.B.; Strong, E.W.; Fass, D.E.; Armstrong, J.G.; Zelefsky, M.J.

    1991-01-01

    This paper assesses tumor control and functional outcome for squamous cancer of the base of the tongue managed with external irradiation plus Ir-192 implant. Between January 1981 and June 1990, 36 previously untreated patients were treated with 5,000-5,400 cGy of external-beam radiation plus a 2,000-3,000 cGy boost to the base of tongue with an Ir-192 implant. Negative necks were irradiated alone, and positive necks were treated with irradiation followed by neck dissection. Crude local control by T stage are as follows: T1, 10 of 11; T2, 13 of 14; T3, 8 of 10; and T4 1 of 1. Actuarial local control is 87.5%. Of the four local failures, two were salvaged by surgery. Neck control was achieved in 35 of 36 patients. Complications occurred in 25%. When implantation was done with the nonlooping technique, the injury rate was statistically higher than when done with the looping technique (6 of 12 = 50% vs 3 of 24 = 12.5%, P = .02)