WorldWideScience

Sample records for rf-focused interdigital linac

  1. Two-beam interdigital-H-type radio frequency quadrupole linac with direct plasma injection for high intensity heavy ion acceleration

    Directory of Open Access Journals (Sweden)

    T. Ishibashi

    2011-06-01

    Full Text Available We developed a two-beam interdigital-H-type radio frequency quadrupole (IH-RFQ linac as a prototype of a multibeam IH-RFQ for high intensity heavy ion acceleration in the low energy region. This linac has two sets of RFQ electrodes within an IH-type resonant frequency cavity that is a power-efficient structure for low energy beam acceleration. The linac can accelerate two beams in parallel in one cavity with a reduction in the coulomb repulsive force (the space charge effect between the accelerated heavy ion particles. The resonance frequency and the Q factor of the linac were found to be 47 MHz and 5900, respectively. We also developed a two-beam laser ion source with a direct plasma injection scheme as an injection system for the two-beam IH-RFQ linac and built a system to demonstrate the use of the two-beam IH-RFQ linac. Using this linac system, we were able to accelerate carbon ions from 5 to 60  keV/u and generate an output beam current of about 108 mA (2×54  mA/channel. A coherency between the two beams, derived from the imbalance of the beam loading, was observed in the acceleration test with carbon ions.

  2. Low-charge-state linac

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Kim, J.W.

    1995-08-01

    A design is being developed for a low-charge-state linac suitable for injecting ATLAS with a low-charge-state, radioactive beam. Initial work indicates that the existing ATLAS interdigital superconducting accelerating structures, together with the superconducting quadrupole transverse focussing element discussed above, provides a basis for a high-performance low-charge-state linac. The initial 2 or 3 MV of such a linac could be based on a normally-conducting, low-frequency RFQ, possibly combined with 24-MHz superconducting interdigital structures. Beam dynamics studies of the whole low-charge-state post-accelerator section were carried out in early FY 1995.

  3. Interdigital filter design

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2009-10-01

    Full Text Available flexible, and allows design tradeoffs to be evaluated in an intuitive way. Keywords: Cavity resonator filters, microwave filters, coupled transmission lines. 1 Introduction Interdigital filters are popular at the higher microwave frequencies for a... number of reasons. Ideal interdigital filters have perfect symmetry which means that they have better phase and delay characteristics than combline filters [1]. The couplings between the resonators of interdigital filters are also lower than those...

  4. Interdigital erosions: Tinea pedis?

    National Research Council Canada - National Science Library

    Orgaz-Molina, Jacinto; Orgaz-Molina, Maria Carmen; Cotugno, Marilena; Arias-Santiago, Salvador

    2012-01-01

    Interdigital erosions are frequently due to tinea pedis. However, other infectious conditions, such as candidiasis, erythrasma or bacterial infections, can generate lesions that cannot be differentiated at the clinical level...

  5. LINAC 4

    CERN Multimedia

    2013-01-01

    On 13 March, a beam of negative hydrogen ions was injected into the first accelerator module of Linac 4, the linear accelerator which will replace Linac 2. The beam was created in the new source built for Linac 4 and accelerated from 45 kEV to 3 MeV by a radiofrequency quadrupole (RFQ) module, the first link in the Linac 4 accelerator chain. This crucial phase went off without a hitch. The video above shows the new Linac 4 ion source, the low-energy transfer line and the RFQ, with running commentary by Giulia Bellodi and Carlo Rossi from the Beams Department.

  6. Linac 2

    CERN Multimedia

    Photographic Service

    1979-01-01

    It was built to obtain higher intensities and better stability than with the original Linac 1. Construction and running-in were completed in 1979, routine operation began in 1980. One sees its 3 tanks, with, at the top, the electrical connections for the quadrupoles (which are inside the drift-tubes) and watercooling. As Linac 1, Linac 2 is driven at 202.56 MHz and accelerates protons to 50 MeV for injection into the 4 rings of the PS Booster.

  7. LINAC4

    CERN Multimedia

    2017-01-01

    The film illustrates CERN’s new linear accelerator for negative hydrogen ions (H-) Linac4. The klystron hall is shown. In the linac4 tunnel: the H- source, the radiofrequency quadrupole (RFQ), Drift tube (DTL), CCDTL and Pi-mode accelerating structure are shown. The H- dump and transfer line gallery towards the PS-booster are shown. Eventually the bird’s eye view of the booster and PS ring accelerators are shown.

  8. LINAC4 Footage (HD)

    CERN Multimedia

    2017-01-01

    Geneva, 9 May 2017. At a ceremony today, CERN inaugurated its linear accelerator, Linac 4, the newest accelerator acquisition since the Large Hadron Collider (LHC). Linac 4 is due to feed the CERN accelerator complex with particle beams of higher energy, which will allow the LHC to reach higher luminosity by 2021. After an extensive testing period, Linac 4 will be connected to CERN’s accelerator complex during the upcoming long technical shut down in 2019-20. Linac 4 will replace Linac 2, which has been in service since 1978. It will become the first step in CERN’s accelerator chain, delivering proton beams to a wide range of experiments

  9. LINAC4 Footage

    CERN Multimedia

    2017-01-01

    Geneva, 9 May 2017. At a ceremony today, CERN inaugurated its linear accelerator, Linac 4, the newest accelerator acquisition since the Large Hadron Collider (LHC). Linac 4 is due to feed the CERN accelerator complex with particle beams of higher energy, which will allow the LHC to reach higher luminosity by 2021. After an extensive testing period, Linac 4 will be connected to CERN’s accelerator complex during the upcoming long technical shut down in 2019-20. Linac 4 will replace Linac 2, which has been in service since 1978. It will become the first step in CERN’s accelerator chain, delivering proton beams to a wide range of experiments

  10. Superconducting Hadron Linacs

    CERN Document Server

    Ostroumov, Peter

    2013-01-01

    This article discusses the main building blocks of a superconducting (SC) linac, the choice of SC resonators, their frequencies, accelerating gradients and apertures, focusing structures, practical aspects of cryomodule design, and concepts to minimize the heat load into the cryogenic system. It starts with an overview of design concepts for all types of hadron linacs differentiated by duty cycle (pulsed or continuous wave) or by the type of ion species (protons, H-, and ions) being accelerated. Design concepts are detailed for SC linacs in application to both light ion (proton, deuteron) and heavy ion linacs. The physics design of SC linacs, including transverse and longitudinal lattice designs, matching between different accelerating–focusing lattices, and transition from NC to SC sections, is detailed. Design of high-intensity SC linacs for light ions, methods for the reduction of beam losses, preventing beam halo formation, and the effect of HOMs and errors on beam quality are discussed. Examples are ta...

  11. Linac 1, inner structure

    CERN Multimedia

    1968-01-01

    This photo shows the inner structure of Linac 1. As injector to the PS, and later to the Booster, Linac 1 accelerated protons to 50 MeV, but it has also accelerated heavier ions. Fitted with a 520 keV RFQ pre-injector (instead of the original Cockcroft-Walton generator), it delivered protons and heavy ions to LEAR, from 1982 to 1992. After 33 years of faithful service, Linac 1 was dismantled in 1992 to make room for Linac 3 (Pb ions).

  12. Linac pre-injector

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    New accelerating column of the linac pre-injector, supporting frame and pumping system. This new system uses two mercury diffusion pumps (in the centre) and forms part of the modifications intended to increase the intensity of the linac. View taken during assembly in the workshop.

  13. Design of APhF-IH Linac for a Compact Medical Accelerator

    CERN Document Server

    Kapin, V; Iwata, Y

    2003-01-01

    The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the tank is assumed. The total length of the structure is about 4.2 m. F...

  14. Compendium of Scientific Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Clendenin, James E

    2003-05-16

    The International Committee supported the proposal of the Chairman of the XVIII International Linac Conference to issue a new Compendium of linear accelerators. The last one was published in 1976. The Local Organizing Committee of Linac96 decided to set up a sub-committee for this purpose. Contrary to the catalogues of the High Energy Accelerators which compile accelerators with energies above 1 GeV, we have not defined a specific limit in energy. Microtrons and cyclotrons are not in this compendium. Also data from thousands of medical and industrial linacs has not been collected. Therefore, only scientific linacs are listed in the present compendium. Each linac found in this research and involved in a physics context was considered. It could be used, for example, either as an injector for high energy accelerators, or in nuclear physics, materials physics, free electron lasers or synchrotron light machines. Linear accelerators are developed in three continents only: America, Asia, and Europe. This geographical distribution is kept as a basis. The compendium contains the parameters and status of scientific linacs. Most of these linacs are operational. However, many facilities under construction or design studies are also included. A special mention has been made at the end for the studies of future linear colliders.

  15. Brookhaven Linac Isotope Producer

    Data.gov (United States)

    Federal Laboratory Consortium — The Brookhaven Linac Isoptope Producer (BLIP)—positioned at the forefront of research into radioisotopes used in cancer treatment and diagnosis—produces commercially...

  16. Progress in Induction Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Caporaso, G J

    2000-09-27

    This presentation will be a broad survey of progress in induction technology over the past four years. Much work has been done on accelerators for hydrodynamic test radiography and other applications. Solid-state pulsers have been developed which can provide unprecedented flexibility and precision in pulse format and accelerating voltage for both ion and electron induction machines. Induction linacs can now be built which can operate with MHz repetition rates. Solid-state technology has also made possible the development of fast kickers for precision control of high current beams. New insulator technology has been developed which will improve conventional induction linacs in addition to enabling a new class of high gradient induction linacs.

  17. The KEKB injector linac

    Energy Technology Data Exchange (ETDEWEB)

    Abe, I.; Akasaka, N.; Akemoto, M.; Anami, S.; Enomoto, A. E-mail: atsushi.enomoto@kek.jp; Flanagan, J.; Fukuda, S.; Fukuma, H.; Funakoshi, Y.; Furukawa, K.; Hanaki, H.; Honma, H.; Iida, N.; Ikeda, M.; Kakihara, K.; Kamikubota, N.; Kamitani, T.; Katagiri, H.; Kawamoto, T.; Kikuchi, M.; Kobayashi, H.; Koiso, H.; Matsumoto, T.; Michizono, S.; Nakahara, K.; Nakajima, H.; Nakao, K.; Ogawa, Y.; Ohnishi, Y.; Ohsawa, S.; Oide, K.; Oogoe, T.; Otake, Y.; Sato, I.; Satoh, K.; Shidara, T.; Shirakawa, A.; Suetake, M.; Suwada, T.; Urano, T.; Yamaguchi, S.; Yano, Y

    2003-02-21

    An 8-GeV electron/3.5-GeV positron injector for KEKB was completed in 1998 by upgrading the existing 2.5-GeV electron/positron linac. The main goals were to upgrade its accelerating energy from 2.5 to 8 GeV and to increase the positron intensity by about 20 times. This article describes not only the composition and features of the upgraded linac, but also how these goals were achieved, by focusing on an optics design and commissioning issues concerning especially high-intensity single-bunch acceleration to produce positron beams.

  18. Interdigitated Electrophotocatalytic Cell for Water Purification

    OpenAIRE

    Guy Shemer; Yaron Paz

    2011-01-01

    The preparation, characterization, and performance of an electrophotocatalytic cell, made of low-cost, planar interdigitated electrodes is reported hereby. The operation of the cell under small positive bias was demonstrated by photocatalytically degrading the dye rhodamine 6G in solution as well as by monitoring the degradation of self-assembled monolayer chemisorbed on the TiO2 electrode. Results point out to the importance of activated oxygen species formed in the process and suggest that ...

  19. The ISS protontherapy LINAC

    Science.gov (United States)

    Picardi, L.; Ronsivalle, C.; Vignati, A.

    1997-02-01

    The TERA foundation stimulated in the past years a comparative study of compact proton accelerators for therapy and at the end of 1995 the Italian National Institute of Health (Istituto Superiore di Sanità, ISS) decided for the construction of a proton linac for its TOP (Terapia Oncologica con Protoni) project. The TOP-LINAC will be composed of a 7 MeV RFQ+DTL injector followed by a 7-65 MeV section of the innovative 3 GHz SCDTL structure and a 65-200 MeV variable energy SCL 3 GHz structure. A 5-cavity model of the SCDTL has been built and measured on a RF test bench while a 11-cavities prototype (accelerating until 12.5 MeV) is under construction and will be assembled within few months. The TOP LINAC whose construction will start at the end of 1996, will be the first linear accelerator dedicated to proton therapy, and the first 3 GHz proton linac. In this paper the accelerator design and the construction schedule will be presented, and the SCDTL structure RF measurements will be discussed.

  20. Recirculated and Energy Recovered Linacs

    CERN Document Server

    Geoffr-Ey-Kraff

    2003-01-01

    Linacs that are recirculated share many characteristics with ordinary linacs, including the ability to accelerate electron beams FR-om an injector to high energy with relatively little (normalized) emittance growth and the ability to deliver ultrashort bunch duration pulses to users. When such linacs are energy recovered, the additional possibility of accelerating very high average beam current arises. Because this combination of beam properties is not possible FR-om either a conventional linac, or FR-om storage rings where emittance and pulse length are set by the equilibrium between radiation damping and quantum excitation of oscillations about the closed orbit, energy recovered linacs are being considered for an increasing variety of applications. These possibilities extend FR-om high power FR-ee-electron lasers and recirculated linac light sources, to electron coolers for high energy colliders or actual electron-ion colliding- beam machines based on an energy recovered linac for the electrons.

  1. Drift tubes of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV PS Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows Linac 2 drift-tubes, suspended on stems coming from the top, in contrast to Linac 1, where the drift-tubes stood on stems coming from the bottom.

  2. Effects Of Field Distortions In Ih-apf Linac

    CERN Document Server

    Kapin, Valery; Yamada, S

    2004-01-01

    The project on developing compact medical accelera-tors for the tumor therapy using carbon ions has been started at the National Institute of Radiological Sciences (NIRS). Alternating-phase-focused (APF) linac using an interdigital H-mode (IH) cavity has been proposed for the injector linac. The IH-cavity is doubly ridged circular resonator loaded by the drift-tubes mounted on ridges with supporting stems. The effects of intrinsic and random field distortions in a practical design of the 4-MeV/u 200 MHz IH-APF linac are considered. The intrinsic field distortions in IH-cavity are caused by the asymmetry of the gap field due to presence of the drift-tube supporting stems and pair of ridges. The random field distortions are caused by drift-tube misalignments and non-regular deviations of the voltage distribution from programmed law. The RF fields in IH-cavity have been calculated using Microwave Studio (MWS) code. The effects of field distortions on beam dynamics have been simulated numerically.

  3. Beam Loss in Linacs

    CERN Document Server

    Plum, M.A.

    2016-01-01

    Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful, beam loss becomes even more critical. Linacs for H- ion beams, such as the one at the Oak Ridge Spallation Neutron Source, have many more loss mechanisms compared to H+ (proton) linacs, such as the one being designed for the European Spallation Neutron Source. Interesting H- beam loss mechanisms include residual gas stripping, H+ capture and acceleration, field stripping, black-body radiation and the recently discovered intra-beam stripping mechanism. Beam halo formation, and ion source or RF turn on/off transients, are examples of beam loss mechanisms that are common for both H+ and H- accelerators. Machine protection systems play an important role in limiting the beam loss.

  4. Interdigitated Electrophotocatalytic Cell for Water Purification

    Directory of Open Access Journals (Sweden)

    Guy Shemer

    2011-01-01

    Full Text Available The preparation, characterization, and performance of an electrophotocatalytic cell, made of low-cost, planar interdigitated electrodes is reported hereby. The operation of the cell under small positive bias was demonstrated by photocatalytically degrading the dye rhodamine 6G in solution as well as by monitoring the degradation of self-assembled monolayer chemisorbed on the TiO2 electrode. Results point out to the importance of activated oxygen species formed in the process and suggest that the short distance between the two electrodes provides a way to utilize the activated oxygen species formed at the negatively biased electrode.

  5. Superconducting linacs: some recent developments

    Energy Technology Data Exchange (ETDEWEB)

    Bollinger, L.M.

    1985-01-01

    The paper is a review of superconducting linacs that are of interest for heavy-ion acceleration. Most of the paper is concerned with energy boosters for projectiles from tandem electrostatic accelerators, the only application for which superconducting linacs are now used for heavy-ion acceleration. There is also a brief discussion of the concept of a superconducting injector linac being developed as a replacement of the tandem in a multi-stage acceleration system. Throughout, the emphasis is on the technology of the superconducting linac, including some attention to the relationships between resonator design parameters and accelerator performance characteristics. 21 refs., 14 figs., 3 tabs.

  6. Development of a very-low-velocity superconducting linac

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.

    1987-01-01

    Four types of superconducting accelerator structures are being developed for use in a low velocity positive-ion injector linac for the ATLAS heavy-ion accelerator. Prototypes of the first two of these have been tested. The structures are all variants of a quarter-wave line terminated with a four-gap interdigital drift-tube array. The two structure types so far tested operate at 48.5 mHz and have an active length of 10 cm (for the particle velocity - .008c type) and 16.5 cm (for the velocity - .014c type). Effective accelerating fields of 10 MV/m have been achieved with the 10 cm structure, corresponding to an effective accelerating potential of 1 MV. The 16.5 cm structure has been operated at field levels of 6 MV/m, also giving an effective potential of 1 MV. Prototypes of the remaining two resonant geometries are under construction.

  7. High intensity ion beams in rf undulator linac

    Directory of Open Access Journals (Sweden)

    E. S. Masunov

    2008-07-01

    Full Text Available The possibility of using a radio frequency undulator field to accelerate a high intensity ion beam in a linac is discussed. Such an accelerator can be realized using the periodical interdigital H-type resonator structure. The accelerating force is produced by an electric field which is a combination of two or more spatial harmonics, none of them being synchronous with the ion beam. The value of this force is proportional to the squared charge. The equations of motion in Hamiltonian form are derived by means of smooth approximation. The analysis of the 3D effective potential function allows finding the conditions of the beam focusing and acceleration. Two ways to increase ion beam intensity are considered: (i to enlarge beam cross section; (ii to neutralize the beam space charge by accelerating ions with opposite charge signs within the same bunch. The basic results are confirmed by a numerical simulation.

  8. Microwave Electron Linacs for Oncology

    Science.gov (United States)

    Whittum, David H.

    The history and technology of medical linacs are reviewed, focusing on machine requirements for radiotherapy. Configurations used in modern machines are described and operational aspects of a gantry-style linac system are illustrated with reference to the state of the art. Aspects of structure design, modeling and testing are discussed.

  9. Linac4 Technical Design Report

    CERN Document Server

    Arnaudon, L; Baylac, M; Bellodi, G; Body, Y; Borburgh, J; Bourquin, P; Broere, J; Brunner, O; Bruno, L; Carli, C; Caspers, Friedhelm; Cousineau, S M; Cuvet, Y; De Almeida Martins, C; Dobers, T; Fowler, T; Garoby, R; Gerigk, F; Goddard, B; Hanke, K; Hori, M; Jones, M; Kahle, K; Kalbreier, Willi; Kroyer, T; Küchler, D; Lombardi, A M; López-Hernandez, L A; Magistris, M; Martini, M; Maury, S; Page, E; Paoluzzi, M; Pasini, M; Raich, U; Rossi, C; Royer, J P; Sargsyan, E; Serrano, J; Scrivens, R; Silari, M; Timmins, M; Venturini-Delsolaro, W; Vretenar, M; Wegner, R; Weterings, W; Zickler, T

    2006-01-01

    Linac4 is an H- linear accelerator, intended to replace Linac2 as injector to the PS Booster (PSB). By delivering to the PSB a beam at 160 MeV energy, Linac4 will provide the conditions to double the brightness and intensity of the beam from the PSB, thus removing the first bottleneck towards higher brightness for the LHC and simplifying operation. Moreover, this new linac constitutes an essential component of any of the envisaged LHC upgrade scenarios and could open the way to future extensions of the CERN accelerator complex towards higher performance. This Technical Design Report presents a detailed technical overview of the Linac4 design as it stands at end 2006.

  10. Self-Aligned Interdigitated Transducers for Acoustofluidics

    Directory of Open Access Journals (Sweden)

    Zhichao Ma

    2016-11-01

    Full Text Available The surface acoustic wave (SAW is effective for the manipulation of fluids and particles at microscale. The current approach of integrating interdigitated transducers (IDTs for SAW generation into microfluidic channels involves complex and laborious microfabrication steps. These steps often require full access to clean room facilities and hours to align the transducers to the precise location. This work presents an affordable and innovative method for fabricating SAW-based microfluidic devices without the need for clean room facilities and alignment. The IDTs and microfluidic channels are fabricated using the same process and thus are precisely self-aligned in accordance with the device design. With the use of the developed fabrication approach, a few types of different SAW-based microfluidic devices have been fabricated and demonstrated for particle separation and active droplet generation.

  11. MRI/linac integration.

    Science.gov (United States)

    Lagendijk, Jan J W; Raaymakers, Bas W; Raaijmakers, Alexander J E; Overweg, Johan; Brown, Kevin J; Kerkhof, Ellen M; van der Put, Richard W; Hårdemark, Björn; van Vulpen, Marco; van der Heide, Uulke A

    2008-01-01

    In radiotherapy the healthy tissue involvement still poses serious dose limitations. This results in sub-optimal tumour dose and complications. Daily image guided radiotherapy (IGRT) is the key development in radiation oncology to solve this problem. MRI yields superb soft-tissue visualization and provides several imaging modalities for identification of movements, function and physiology. Integrating MRI functionality with an accelerator can make these capacities available for high precision, real time IGRT. The system being built at the University Medical Center Utrecht is a 1.5T MRI scanner, with diagnostic imaging functionality and quality, integrated with a 6MV radiotherapy accelerator. The realization of a prototype of this hybrid system is a joint effort between the Radiotherapy Department of the University of Utrecht, the Netherlands, Elekta, Crawley, U.K., and Philips Research, Hamburg, Germany. Basically, the design is a 1.5 T Philips Achieva MRI scanner with a Magnex closed bore magnet surrounded by a single energy (6 MV) Elekta accelerator. Monte Carlo simulations are used to investigate the radiation beam properties of the hybrid system, dosimetry equipment and for the construction of patient specific dose deposition kernels in the presence of a magnetic field. The latter are used to evaluate the IMRT capability of the integrated MRI linac. A prototype hybrid MRI/linac for on-line MRI guidance of radiotherapy (MRIgRT) is under construction. The aim of the system is to deliver the radiation dose with mm precision based on diagnostic quality MR images.

  12. [Interdigital and foot fungal infection in patients with onychomycosis].

    Science.gov (United States)

    Chanussot, Caroline; Arenas, Roberto

    2007-06-01

    In patients with onychomycosis (OM) 71.5% of them have been reported with plantar fungal infection. The aim of this study was to study the frequency and distribution of plantar and interdigital affection in diabetic patients and in a control group without diabetes, all of them with OM. Diabetic patients with OM were more frequently diagnosed with plantar (61.2%) than interdigital (46.7%) infection. In the control group similar results were obtained; patients with OM in 76.5% had plantar mycotic infection and 67.1% interdigital involvement.

  13. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  14. Installation of the Gbar LINAC

    CERN Multimedia

    Maximilien, Brice

    2017-01-01

    Installation of the GBAR linac in its shielding bunker. The electrons accelerated to 10 MeV toward a target will produce the positrons that are necessary to form anti hydrogen with the antiprotons coming from the ELENA decelerator.

  15. Comparison of LINAC-4 Designs

    CERN Document Server

    Crandall, K; Sargsyan, E; Lallement, J-B; CERN. Geneva. BE Department

    2009-01-01

    We have studied the expected performance of two drift tube linac (DTL) designs proposed for LINAC-4. The two designs use the same cell geometries but are characterized by different phase (φs) and accelerating field (E0) distributions. In addition we have investigated the expected performance of 3 different quadrupole focusing schemes in each design. The expected performance of these 6 variants is compared with respect to their stability and risk of beam loss with alignment errors.

  16. Inner structure of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows the inner structure of Linac 2, with drift-tubes hanging on stems under a rigid support structure, soon to be mounted inside tank 1 (750 keV to 10 MeV, the lowest-energy one of 3). Frank Malthouse is standing in the background.

  17. Testing begins on Linac4

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    On 3 August 2012, the Linac4 radiofrequency quadrupole (RFQ) module was installed at the accelerator test-stand in Building 152. The site will be the module’s home for almost a year, as the linear accelerator enters the assembly and testing stage.   Final module assembly is carried out before installation in Building 152.  Over the next Long Shutdown (LS2), Linac4 will replace the current Linac2 linear accelerator as the first link in CERN’s accelerator chain. It will deliver particles at 160 MeV to the PS Booster, more than triple the energy currently delivered by Linac2. But before the accelerator team can pop the champagne, the various elements of Linac4 will be tested and re-tested in facilities across CERN. “The first Linac4 tests are currently underway, starting with the CERN-built RFQ,” says Carlo Rossi, a physicist in the RF Group of the Beams (BE) Department and the RFQ project coordinator. “It’s an extremely impre...

  18. Cyclic biamperometry at micro-interdigitated electrodes.

    Science.gov (United States)

    Rahimi, Mehdi; Mikkelsen, Susan R

    2011-10-01

    Cyclic biamperometry was studied as an analytical method for use with commercially available, comb-type, coplanar microinterdigitated electrodes (μIDEs), using the ferri-/ferrocyanide redox couple as a model analyte. The μIDEs studied in this work were made of gold that had been deposited onto a Ti/W adhesion layer on borosilicate glass chips and had 5 and 10 μm bands with equal gap sizes. Close proximity of the two working electrodes, and their interdigitation, resulted in signal amplification by redox cycling. Results were compared with those obtained by cyclic voltammetry, where one of the two IDE electrodes was used as the working electrode and external reference and auxiliary electrodes were used. Amplification factors of almost 20 were achieved due to redox cycling. Attempts to apply cyclic voltammetry to the μIDEs, with one of the combs as the working and the other as the auxiliary electrode, were unsuccessful due to corrosion of the auxiliary electrode comb. Results of this study, and the electrochemically unique feature of biamperometry to probe but not change the net contents of the medium under examination, suggest the applicability of scanning biamperometry at μIDEs to the very small volumes and electrochemical cell dimensions that are now of great interest.

  19. Superconducting LINAC booster for the Mumbai pelletron

    Indian Academy of Sciences (India)

    LINAC), to boost the energy of heavy ion beams from the 14UD Pelletron accelerator, at Tata Institute of Fundamental Research, Mumbai. The accelerating structures in the LINAC are quarter wave resonators (QWR) coated with lead which is ...

  20. Linac3 - 1992-1994

    CERN Multimedia

    CERN; A Van der Shueren; Jean-Claude Vialis

    1995-01-01

    This film reports the differents steps of the construction in differents places (Italy, Germany, France) from 29 October 1992 to 29 April 1994. This linac, commissioned in summer 1994, presently provides beams of 208Pb53+. A 14 GHz ECR ion source operating in the "afterglow" mode produces Pb 27+ ions at 2.5 keV/u. This beam is accelerated in an RFQ and a three tank IH linac to 4.2 MeV/u where stripping in a 1 um carbon foil to a charge state distribution centered around Pb53+ takes place. 53+ ions are selected from this mixture in a magnetic filter before being transported to the PS Booster and other circular machines. Linac3, the more common name for this machine, was built by a truly international collaboration involving France, Italy, Germany, Italy, Sweden, Switzerland, India, the Czech Republic and CERN.

  1. SUPERCONDUCTING LINAC FOR THE SPALLATION NEUTRON SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    J. STOVALL; S. NATH; ET AL

    2000-10-01

    The Spallation Neutron Source (SNS) linac is comprised of both normal and superconducting rf (SRF) accelerating structures. The SRF linac accelerates the beam from 186 to 1250 MeV through 117 elliptical, multi-cell niobium cavities. This paper describes the SRF linac architecture, physics design considerations, cavity commissioning, and the expected beam dynamics performance.

  2. Interdigitated electrodes as impedance and capacitance biosensors: A review

    Science.gov (United States)

    Mazlan, N. S.; Ramli, M. M.; Abdullah, M. M. A. B.; Halin, D. S. C.; Isa, S. S. M.; Talip, L. F. A.; Danial, N. S.; Murad, S. A. Z.

    2017-09-01

    Interdigitated electrodes (IDEs) are made of two individually addressable interdigitated comb-like electrode structures. IDEs are one of the most favored transducers, widely utilized in technological applications especially in the field of biological and chemical sensors due to their inexpensive, ease of fabrication process and high sensitivity. In order to detect and analyze a biochemical molecule or analyte, the impedance and capacitance signal need to be obtained. This paper investigates the working principle and influencer of the impedance and capacitance biosensors. The impedance biosensor depends on the resistance and capacitance while the capacitance biosensor influenced by the dielectric permittivity. However, the geometry and structures of the interdigitated electrodes affect both impedance and capacitance biosensor. The details have been discussed in this paper.

  3. Heel erosion and other interdigital disorders in dairy cows

    DEFF Research Database (Denmark)

    Enevoldsen, Carsten; Gröhn, Y.T.; Thysen, Iver

    1991-01-01

    Epidemiologic associations between variables obtainable from dairy cow records and the occurrence of heel erosion, interdigital dermatitis, and interdigital hyperplasia at claw trimmings were estimated with multivariable logistic regression analysis on data from 1170 and 542 cows in lactation 1...... and lactations 2 to 9, respectively. In the 17 herds, heel erosion, interdigital dermatitis, and hyperplasia occurred among 43.8, 4.5, and .9% of cows in lactation 1 and among 69.1, 7.6 and 5.9% of cows in lactations 2 to 9, respectively. Severity of heel erosion increased with parity, and risk increased...... with stage of lactation. Strong seasonal effects were present. Various combinations of veterinary treatments were associated with heel erosion and hyperplasia depending on parity, stage of lactation, and the presence of other claw disorders. In contrast, veterinary treatment had a protective effect...

  4. Microstrip Cross-coupled Interdigital SIR Based Bandpass Filter

    Directory of Open Access Journals (Sweden)

    R. K. Maharjan

    2012-09-01

    Full Text Available A simple and compact 4.9 GHz bandpass filter for C-band applications is proposed. This paper presents a novel microstrip cross-coupled interdigital half-wavelength stepped impedance resonator (SIR based bandpass filter (BPF.The designed structure is similar to that of a combination of two parallel interdigital capacitors. The scattering parameters of the structure are measured using vector network analyzer (VNA. The self generated capacitive and inductive reactances within the interdigital resonators exhibited in a resonance frequency of 4.9 GHz. The resonant frequency and bandwidth of the capacitive cross-coupled resonator is directly optimized from the physical arrangement of the resonators. The measured insertion loss (S21 and return loss (S11 were 0.3 dB and 28 dB, respectively, at resonance frequency which were almost close to the simulation results.

  5. Drift Tube Linac Conditioning of Tank1

    CERN Document Server

    Shafqat, N; Toor, W A

    2014-01-01

    Tank1 of the Drift Tube Linac (DTL) of the Linac4 has been conditioned at the Linac4 tunnel. The tank was tuned for resonance at 352.2 MHz, and stable operation has been achieved with 725 µs long RF pulses at a repetition rate of 1 Hz. The maximum RF level that has been reached is 810 kW with a pulse width of 600 µs. Since this was the first RF structure exclusively conditioned in the Linac4 tunnel with the operation and control software of Linac4, some related issues and limitations had to be taken into account.

  6. The new Linac moves mountains

    CERN Document Server

    2008-01-01

    The civil engineering work has started for Linac 4, one of the major renovation projects for the CERN accelerator complex. The work will be completed at the end of 2010 and the new linear accelerator is scheduled to be commissioned in 2013.

  7. PROGRESS IN DESIGN OF THE SNS LINAC

    Energy Technology Data Exchange (ETDEWEB)

    R. HARDEKOPF

    2000-11-01

    The Spallation Neutron Source (SNS) is a six-laboratory collaboration to build an intense pulsed neutron facility at Oak Ridge, TN. The linac design has evolved from the conceptual design presented in 1997 to achieve higher initial performance and to incorporate desirable upgrade features. The linac will initially produce 2-MW beam power using a combination of radio-frequency quadruple (RFQ) linac, drift-tube linac (DTL), coupled-cavity linac (CCL), and superconducting-cavity linac (SCL). Designs of each of these elements support the high peak intensity and high quality beam required for injection into the SNS accumulator ring. This paper will trace the evolution of the linac design, the cost and performance factors that drove architecture decisions, and the progress made in the R&D program.

  8. A 25.5 MHz double-coaxial lambda/4-resonator as a rebuncher in heavy ion linac system

    CERN Document Server

    Yoshida, K; Hashimoto, Y; Masuda, H; Niki, K

    1999-01-01

    A 25.5 MHz double-coaxial lambda/4-resonator has been constructed to be used as a rebuncher between a 25.5 MHz RFQ linac and a 51 MHz interdigital-H linac for the acceleration of short-lived nuclei. By employing a double coaxial structure, the resonator length is only 130 cm; the length of the natural lambda/4-resonator is 294 cm. The resonator, 69 cm in inner diameter, has six acceleration gaps. The bare shunt impedance is 40.6 M OMEGA/m. The ions with a charge-to-mass ratio 1/10 can be rebunched by feeding an rf power of 1.4 kW.

  9. Water-dispersible nanoparticles via interdigitation of sodium ...

    Indian Academy of Sciences (India)

    The water-dispersible gold nanoparticles have been investigated by UV-Vis spectroscopy, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and Fourier transform infrared spectroscopy (FTIR). These studies indicate the presence of interdigitated bilayers consisting of an ODA primary monolayer ...

  10. Superconducting low-velocity linac for the Argonne positive-ion injector

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Markovich, P.K.; Zinkann, G.P.; Clifft, B.; Benaroya, R.

    1989-01-01

    A low-velocity superconducting linac has been developed as part of a positive-ion injector system, which is replacing a 9 MV tandem as the injector for the ATLAS accelerator. The linac consists of an independently phased array of resonators, and is designed to accelerate various ions over a velocity range .008 < v/c < .06. The resonator array is formed of four different types of superconducting interdigital structures. The linac is being constructed in three phases, each of which will cover the full velocity range. Successive phases will increase the total accelerating potential and permit heavier ions to be accelerated. Assembly of the first phase was completed in early 1989. In initial tests with beam, a five-resonator array provided approximately 3.5 MV of accelerating potential and operated without difficulty for several hundred hours. The second phase is scheduled for completion in late 1989, and will increase the accelerating potential to more than 8 MV. 5 refs., 2 figs., 1 tab.

  11. Effects of Field Distortions in IH-APF Linac for a Compact Medical Accelerator

    CERN Document Server

    Kapin, Valery; Yamada, Satoru

    2004-01-01

    The project on developing compact medical accelerators for the tumor therapy using carbon ions has been started at the National Institute of Radiological Sciences (NIRS). Alternating-phase-focused (APF) linac using an interdigital H-mode (IH) cavity has been proposed for the injector linac. The IH-cavity is a doubly ridged circular resonator loaded by the drift-tubes mounted on ridges with supporting stems. The effects of intrinsic and random field distortions in a practical design of the 4-Mev/u 200-MHz IH-APF linac are considered. The intrinsic field distortions in the IH-cavity are caused by an asymmetry of the gap fields due to presence of the stems and pair of ridges. The random field distortions are caused by drift-tube misalignments and non-regular deviations of the gap voltages from programmed values. The RF fields in the IH-cavity have been calculated using Microwave Studio (MWS) code. The effects of field distortions on beam dynamics have been simulated numerically. The intrinsic field distortions a...

  12. first tank of Linac 1

    CERN Multimedia

    This was the first tank of the linear accelerator Linac1, the injection system for the Proton Synchrotron, It ran for 34 years (1958 - 1992). Protons entered at the far end and were accelerated between the copper drift tubes by an oscillating electromagnetic field. The field flipped 200 million times a second (200 MHz) so the protons spent 5 nanoseconds crossing a drift tube and a gap. Moving down the tank, the tubes and gaps had to get longer as the protons gained speed. The tank accelerated protons from 500 KeV to 10 MeV. Linac1 was also used to accelerate deutrons and alpha particles for the Intersecting Storage Rings and oxygen and sulpher ions for the Super Proton Synchrotron heavy ion programme.

  13. LFSC - Linac Feedback Simulation Code

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Valentin; /Fermilab

    2008-05-01

    The computer program LFSC (<Linac Feedback Simulation Code>) is a numerical tool for simulation beam based feedback in high performance linacs. The code LFSC is based on the earlier version developed by a collective of authors at SLAC (L.Hendrickson, R. McEwen, T. Himel, H. Shoaee, S. Shah, P. Emma, P. Schultz) during 1990-2005. That code was successively used in simulation of SLC, TESLA, CLIC and NLC projects. It can simulate as pulse-to-pulse feedback on timescale corresponding to 5-100 Hz, as slower feedbacks, operating in the 0.1-1 Hz range in the Main Linac and Beam Delivery System. The code LFSC is running under Matlab for MS Windows operating system. It contains about 30,000 lines of source code in more than 260 subroutines. The code uses the LIAR ('Linear Accelerator Research code') for particle tracking under ground motion and technical noise perturbations. It uses the Guinea Pig code to simulate the luminosity performance. A set of input files includes the lattice description (XSIF format), and plane text files with numerical parameters, wake fields, ground motion data etc. The Matlab environment provides a flexible system for graphical output.

  14. The LINAC4 Power Coupler

    CERN Document Server

    Gerigk, F; Montesinos, E; Riffaud, B; Ugena Tirado, P; Wegner, R

    2011-01-01

    Linac4 is employing three types of accelerating structures after the RFQ: a Drift Tube Linac (DTL), a Cell- Coupled DTL (CCDTL), and a Pi-Mode Structure (PIMS) to accelerate the beam up to 160 MeV at 352.2MHz. The structures are designed for a peak power of approximately 1 MW per power coupler, which is transported via rectangular waveguides from the klystron gallery to the RF cavities. The coupler itself consists of two parts: a ceramic window, which separates the cavity vacuum from the air in the waveguides, and a Tuner-adjustablewaveguide Coupler (TaCo), which couples the RF power through an iris to the cavity. In the frame of the Linac4 R&D both devices have been significantly improvedwith respect to their commonly used design. On the coupler side, the waveguide short circuit with its matched length has been replaced by a fixedlength /4 short circuit. The RF matching is done by a simple piston tuner, which allows a quick matching to different cavity quality factors. In the window part, which usually c...

  15. Post-accelerator LINAC design for the VECC RIB project

    Indian Academy of Sciences (India)

    accelerator LINAC design for the VECC RIB project. Arup Bandyopadhyay. Volume 59 Issue 6 December ... and LINAC modules for the post-acceleration. The design aspects of these postaccelerator LINAC modules will be discussed in this paper.

  16. Status of the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Galayda, John N.; /SLAC

    2011-11-04

    The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

  17. Piezoelectric energy harvester having planform-tapered interdigitated beams

    Science.gov (United States)

    Kellogg, Rick A [Tijeras, NM; Sumali, Hartono [Albuquerque, NM

    2011-05-24

    Embodiments of energy harvesters have a plurality of piezoelectric planform-tapered, interdigitated cantilevered beams anchored to a common frame. The plurality of beams can be arranged as two or more sets of beams with each set sharing a common sense mass affixed to their free ends. Each set thus defined being capable of motion independent of any other set of beams. Each beam can comprise a unimorph or bimorph piezoelectric configuration bonded to a conductive or non-conductive supporting layer and provided with electrical contacts to the active piezoelectric elements for collecting strain induced charge (i.e. energy). The beams are planform tapered along the entirety or a portion of their length thereby increasing the effective stress level and power output of each piezoelectric element, and are interdigitated by sets to increase the power output per unit volume of a harvester thus produced.

  18. Interdigital tissue regression in the developing limb of vertebrates

    OpenAIRE

    Lorda Diez, Carlos Ignacio; Montero Simón, Juan Antonio; García-Porrero Pérez, Juan Antonio; Hurlé González, Juan Mario

    2015-01-01

    ABSTRACT Here we we have chosen the regression of the interdigital tissue which sculpts the digits from the hand/foot plate in tetrapod embryos to review the most relevant aspects concerning the regulation and biological significance of programmed cell death. We gather abundant information showing that the initiation of the degenerative process is the result of a complex interplay between the different signaling pathways which are also responsible for limb outgrowth and skeletal tissue differ...

  19. An Induction Linac Test Stand

    CERN Document Server

    De Hope, William; Kihara, Ron; Ong, Mike; Vogtlin, George; Zentler, Jan-Mark

    2005-01-01

    A single-cell test stand has been constructed to facilitate study and guide improvements of the induction electron linac at the FXR radiographic facility at LLNL.* This paper will discuss how modifications in pulse compression and shaping, pulse power transmission, initial ferrite state, and accelerator cell loading have been performed on the test stand and can be applied to the entire accelerator. Some of the specialized diagnostics being used will be described. Finally, the paper will discuss how computer modeling and judicious timing control can be used to optimize accelerator performance by making only selective changes that can be accomplished at minimal cost.

  20. Phase rotation channel design with induction linacs

    CERN Document Server

    Fukui, Y

    2001-01-01

    Two models of the phase rotation channels of the neutrino factory were designed with a solenoid transport system and the induction linac acceleration system. One model has the one stage induction linac channel, and another model has two stages of the induction linac channels and an absorber and drift space in between them. Major figure of merits of the channel are the particle ratio of muons over primary protons, the momentum spread and the muon polarization correlation to the arrival time at the end of the phase rotation channel. The mu/proton ratios were 0.25 and 0.13 for the single stage and the double stage induction linac channels, respectively. The effective muon polarization, radicalradical, was 0.16 and the muon polarization correlation was 0.23/(100 ns) for the single stage induction linac model.

  1. High gradient linac for proton therapy

    Science.gov (United States)

    Benedetti, S.; Grudiev, A.; Latina, A.

    2017-04-01

    Proposed for the first time almost 30 years ago, the research on radio frequency linacs for hadron therapy experienced a sparkling interest in the past decade. The different projects found a common ground on a relatively high rf operating frequency of 3 GHz, taking advantage of the availability of affordable and reliable commercial klystrons at this frequency. This article presents for the first time the design of a proton therapy linac, called TULIP all-linac, from the source up to 230 MeV. In the first part, we will review the rationale of linacs for hadron therapy. We then divided this paper in two main sections: first, we will discuss the rf design of the different accelerating structures that compose TULIP; second, we will present the beam dynamics design of the different linac sections.

  2. High gradient linac for proton therapy

    Directory of Open Access Journals (Sweden)

    S. Benedetti

    2017-04-01

    Full Text Available Proposed for the first time almost 30 years ago, the research on radio frequency linacs for hadron therapy experienced a sparkling interest in the past decade. The different projects found a common ground on a relatively high rf operating frequency of 3 GHz, taking advantage of the availability of affordable and reliable commercial klystrons at this frequency. This article presents for the first time the design of a proton therapy linac, called TULIP all-linac, from the source up to 230 MeV. In the first part, we will review the rationale of linacs for hadron therapy. We then divided this paper in two main sections: first, we will discuss the rf design of the different accelerating structures that compose TULIP; second, we will present the beam dynamics design of the different linac sections.

  3. The DARHT Phase 2 Linac

    Energy Technology Data Exchange (ETDEWEB)

    wolf, Zachary R.

    2000-09-12

    The second phase accelerator for the Dual Axis Hydrodynamic Test facility (DARHT) is designed to provide an electron beam pulse that is 2{mu}s long, 2kA, and 20 MeV in particle energy. The injector provides 3.2 MeV so that the linac need only provide 16.8 MeV. The linac is made with two types of induction accelerator cells. The first block of 8 cells have a 14 in. beam pipe compared to 10 in. in the remaining 80 cells. The other principal difference is that the first 8 cells have reduced volt-sec in their induction cores as a result of a larger diameter beam pipe. The cells are designed for very reliable high voltage operation. The insulator is Mycalex. Results from prototype tests are given including results from solenoid measurements. Each cell contains a solenoid for beam transport and a set of x-y correction coils to reduce corkscrew motion. Details of tests to determine RF mode impedances relevant to BBU generation are given. Blocks of cells are separated by intercells some of which contain transport solenoids. The intercells provide vacuum pumping stations as well. Issues of alignment and installation are discussed.

  4. Design and Fabrication of Interdigital Nanocapacitors Coated with HfO2

    Directory of Open Access Journals (Sweden)

    Gabriel González

    2015-01-01

    Full Text Available In this article nickel interdigital capacitors were fabricated on top of silicon substrates. The capacitance of the interdigital capacitor was optimized by coating the electrodes with a 60 nm layer of HfO2. An analytical solution of the capacitance was compared to electromagnetic simulations using COMSOL and with experimental measurements. Results show that modeling interdigital capacitors using Finite Element Method software such as COMSOL is effective in the design and electrical characterization of these transducers.

  5. 25th anniversary for Linac-2

    CERN Multimedia

    2003-01-01

    On Friday, 3 October 2003, the Linac team celebrated a quarter century of successful operation of one of its linear accelerators: Linac-2, the proton workhorse of the CERN accelerator complex. Linac-2, CERN's linear proton accelerator, has now been running for 25 years - ample reason for a small celebration. About 30 members of the original team (10 of the initially more than 50 are still working at CERN), and other CERN personnel met on 3 October 2003. Linac-2 is the first link in the accelerator chain Linac-2 - PS Booster - PS - SPS and eventually LHC. Beams from Linac-2 are used after further acceleration in the CERN complex for SPS fixed target physics; for antiproton production for the Antiproton Decelerator (AD); for test beams in the East Experimental Hall and in the PS; for nuclear physics at ISOLDE; for LHC test beams and in the past for both ISR physics and Antiproton production (AA/AC) and test beams in LEAR. Linac-2 was built to obtain higher intensities and better stability than with ...

  6. Source and LINAC3 studies

    CERN Document Server

    Bellodi, G

    2017-01-01

    In the framework of the LHC Ion Injector Upgrade pro-gramme (LIU), several activities have been carried out in2016 to improve the ion source and Linac3 performance,with the goal to increase the beam current routinely deliv-ered to LEIR. The extraction region of the GTS-LHC ionsource was upgraded with enlarged vacuum chamber aper-tures and the addition of an einzel lens, yielding highertransmission through the rest of the machine. Also, a seriesof experiments have been performed to study the effects ofdouble frequency mixing on the afterglow performance ofthe source after installation of a Travelling Wave Tube Am-plifier (TWTA) as secondary microwave source at variablefrequency. Measurements have been carried out at a dedi-cated oven test stand for better understanding of the ionsource performance. Finally, several MD sessions werededicated to the study and characterization of the strippingfoils, after evidence of degradation in time was discoveredin the 2015 run.

  7. Development of two-dimensional interdigitated center of pressure sensor

    Science.gov (United States)

    Yoo, Byungseok; Pines, Darryll J.

    2017-12-01

    This paper presents the development of a two-dimensional (2D) flexible patch sensor to detect and monitor the center of pressure (CoP) location and the total magnitude of a spatially distributed pressure to the specific surface areas of engineering structures. The CoP sensor with the contact mode induced by a pressure distribution was formulated by force sensitive resistor technology and was mainly composed of a thin conductive polymer layer, adhesive spacers, and two interdigitated patterned electrode films with unique sensing aperture shadings. By properly mapping the interdigitated electrode patterns to the top and bottom surfaces of the conductive polymer, the proposed sensor ideally enables to measure an overall applied pressure level and its centroid location within a predetermined sensing region in real-time. The CoP sensor containing 36 sensing sections within a dimension of around 3 × 3 inches was prototyped and experimentally investigated to verify its capability to identify the CoP location and magnitude due to the presence of a permanent magnet-based local pressure distribution. Only five electric wires connected to the CoP sensor to inspect the pressure-sensing positions of 36 segments. The evaluation results of the measured sensor data demonstrate good agreements with the actual test parameters such as the total pressure and its centroid position with about 5% locational error. However, to provide accurate information on the overall pressure range, the compensation factors must be determined and applied to the individual sensing sections of the sensor.

  8. Overview of LINAC4 Beam Instrumentation Software

    CERN Document Server

    Jensen, L K; Guerrero, A; Kolad, B; Ludwig, M; Raich, U; Roncarolo, F

    2014-01-01

    This paper presents an overview of results from the recent Linac4 commissioning with H- beam at CERN. It covers beam instrumentation systems acquiring beam intensity, position, transverse and longitudinal profile and transverse emittance

  9. The invention that is shaping Linac4

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Accelerator experts are no strangers to innovative optimizations of existing techniques and to the development of novel solutions. Sometimes, they even come up with ideas that have the potential to revolutionize the field. This is the case with the Tolerance Aligned Cantilever Mounting (TACM) system, a completely new way of supporting the drift tubes, one of the core elements of linear accelerators. The new, patent-pending technique will be implemented at Linac4.   Drift tubes in a prototype for Linac4, assembled using the new TACM technology. “Assemble and adjust” – that was the technique used to build drift-tube linacs before the arrival of the TACM. Now, the inventors’ motto has become ‘adjust and assemble’. The inversion of these two words represents a real revolution for people working in the field. “The drift tubes are a critical element of Linac4 and they have to satisfy several requirements: they have to be mechanically ...

  10. The LINAC4 Project at CERN

    CERN Document Server

    Arnaudon, L; Bertone, C; Body, Y; Broere, J; Brunner, O; Buzio, M; Carli, C; Caspers, F; Corso, JP; Coupard, J; Dallocchio, A; Dos Santos, N; Garoby, R; Gerigk, F; Hammouti, L; Hanke, K; Jones, M; Kozsar, I; Lettry, J; Lallement, JB; Lombardi, A; Lopez-Hernandez, LA; Maglioni, C; Mathot, S; Maury, S; Mikulec, B; Nisbet, D; Noels, C; Paoluzzi, M; Puccio, B; Raich, U; Ramberger, S; Rossi, C; Schwerg, N; Scrivens, R; Vandoni, G; Weisz, S; Vollaire, J; Vretenar, M; Zickler, T

    2011-01-01

    As the first step of a long-term programme aiming at an increase in the LHC luminosity, CERN is building a new 160 MeV H¯ linear accelerator, Linac4, to replace the ageing 50 MeV Linac2 as injector to the PS Booster (PSB). Linac4 is an 86-m long normal-conducting linac made of an H¯ source, a Radio Frequency Quadrupole (RFQ), a chopping line and a sequence of three accelerating structures: a Drift-Tube Linac (DTL), a Cell-Coupled DTL (CCDTL) and a Pi-Mode Structure (PIMS). The civil engineering has been recently completed, and construction of the main accelerator components has started with the support of a network of international collaborations. The low-energy section up to 3 MeV including a 3-m long 352 MHz RFQ entirely built at CERN is in the final construction phase and is being installed on a dedicated test stand. The present schedule foresees beam commissioning of the accelerator in the new tunnel in 2013/14; the moment of connection of the new linac to the CERN accelerator chain will depend on the L...

  11. Gas sensing performance at room temperature of nanogap interdigitated electrodes for detection of acetone at low concentration

    NARCIS (Netherlands)

    Minh, Q. Nguyen; Tong, H.D.; Kuijk, A.; van de Bent, F.; Beekman, Pepijn; Van Rijn, C. J.M.

    2017-01-01

    A facile approach for the fabrication of large-scale interdigitated nanogap electrodes (nanogap IDEs) with a controllable gap was demonstrated with conventional micro-fabrication technology to develop chemocapacitors for gas sensing applications. In this work, interdigitated nanogap electrodes

  12. Numerical analysis on effective electric field penetration depth for interdigital impedance sensor

    Science.gov (United States)

    Kim, Chon-ung; Li, Guofeng; Li, Jie; Jong, Hakchol; Ro, Cholwu; Song, Yunho; Pak, Gilhung; Im, Songil

    2013-03-01

    Interdigital (finger-like) electrodes are widely used for electrical impedance and capacitance tomography of composite dielectric materials and complex insulating structures. Because of their advantages, they are now effectively introduced as capacitance sensors into a variety of industrial branches, agriculture, medical science, biological engineering, military branches, etc. In order to effectively apply the so-called interdigital impedance sensors in practice, of great importance is to optimize the sensor design parameters such as the electric field penetration depth, signal strength and so on. The general design principles of the interdigital capacitance sensor have been discussed for a long time by many researchers. However, there is no consensus on the definition of the effective electric field penetration depth of interdigital electrode. This paper discusses how to determine the effective electric field penetration depth of interdigital sensor on the basis of the refractive principle of electric field intensity and the FEM analyses of electric field distribution and capacitance for the sensor model.

  13. Quantitative analysis of microtubule orientation in interdigitated leaf pavement cells.

    Science.gov (United States)

    Akita, Kae; Higaki, Takumi; Kutsuna, Natsumaro; Hasezawa, Seiichiro

    2015-01-01

    Leaf pavement cells are shaped like a jigsaw puzzle in most dicotyledon species. Molecular genetic studies have identified several genes required for pavement cells morphogenesis and proposed that microtubules play crucial roles in the interdigitation of pavement cells. In this study, we performed quantitative analysis of cortical microtubule orientation in leaf pavement cells in Arabidopsis thaliana. We captured confocal images of cortical microtubules in cotyledon leaf epidermis expressing GFP-tubulinβ and quantitatively evaluated the microtubule orientations relative to the pavement cell growth axis using original image processing techniques. Our results showed that microtubules kept parallel orientations to the growth axis during pavement cell growth. In addition, we showed that immersion treatment of seed cotyledons in solutions containing tubulin polymerization and depolymerization inhibitors decreased pavement cell complexity. Treatment with oryzalin and colchicine inhibited the symmetric division of guard mother cells.

  14. A capacitive biosensor based on an interdigitated electrode with nanoislands.

    Science.gov (United States)

    Jung, Ha-Wook; Chang, Young Wook; Lee, Ga-yeon; Cho, Sungbo; Kang, Min-Jung; Pyun, Jae-Chul

    2014-09-24

    A capacitive biosensor based on an interdigitated electrode (IDE) with nanoislands was developed for label-free detection of antigen-antibody interactions. To enable sensitive capacitive detection of protein adsorption, the nanoislands were fabricated between finger electrodes of the IDE. The effect of the nanoislands on the sensitive capacitive measurement was estimated using horseradish peroxidase (HRP) as a model protein. Additionally, a parylene-A film was coated on the IDE with nanoislands to improve the efficiency of protein immobilization. By using HRP and hepatitis B virus surface antigen (HBsAg) as model analytes, the effect of the parylene-A film on the capacitive detection of protein adsorption was demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Fluid streaming above interdigitated electrodes in dielectrophoresis experiments.

    Science.gov (United States)

    Stanke, Sandra; Bier, Frank F; Hölzel, Ralph

    2011-09-01

    For the investigation of alternating current electrokinetic effects, a system is presented that allows for the simultaneous observation of fluid flow above and around microelectrodes in all three directions in space. Beside the usual microscopical view from top, lateral observation through the same objective is made possible by two small mirrors that are placed next to the electrodes. Fluid flow and movement of fluorescent nanoparticles above interdigitated electrodes are monitored by fluorescence microscopy and digital imaging and are further analysed by image processing. Field frequencies are varied from 10 Hz to 1 GHz at up to 10V(rms) . Electrical conductivity of the fluid is monitored in situ in the actual measuring chamber. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. CERN Linac4. The space charge challenge

    Energy Technology Data Exchange (ETDEWEB)

    Hein, Lutz Matthias

    2013-08-06

    In the first phase of the upgrade program of the CERN accelerator complex the proton injector Linac2 will be replaced by a new, normal-conducting H-ion Linac, Linac4, allowing a significant increase of the proton flux intensity along the downstream accelerator complex. In the design of Linac4 three beam transport sections are implemented to match the beam between the different accelerator elements and to model the longitudinal pulse structure. These three beam transport sections, which are the most critical locations in terms of beam quality preservation, are in the focus of this thesis. During the work of this thesis the Low Energy Beam Transport (LEBT), which is required to match the source beam to the radiofrequency quadrupole (RFQ), has been commissioned and its beam dynamics re-constructed. The measurement campaign used to reconstruct the LEBT beam dynamics was performed with the aim to prepare the RFQ commissioning and to maximise the LEBT performance. Downstream of the Linac4 accelerator the beam is transported along a 180 m long transfer line to the Proton Synchrotron Booster (PS-Booster). The transfer line optics was studied, optimised and sections were completely re-designed. The new transfer line optics is characterised by an improved preservation of the beam emittance, higher stability of the optical solution with respect to alignment errors and field jitters of the transfer line magnets and it is matched to each of the PS-Booster injection schemes. In a concluding ''Start-To-End'' simulation based on the measured beam characteristics at the LEBT exit the beam dynamics of the downstream Linac, including the transfer line, was calculated. To minimise particle losses within acceptable emittance preservation the beam optics of the Medium Energy Beam Transport (MEBT) was adapted to the measured beam parameters. This ''Start-To-End'' simulation was performed to identify critical sections of the Linac4 beam dynamics and

  17. Frequency jump in an ion linac

    Directory of Open Access Journals (Sweden)

    R. Duperrier

    2007-08-01

    Full Text Available Frequency jumps in an ion linac use to be made in order to provide a large transverse acceptance in the low-energy part and a high accelerating gradient in the high-energy part. This frequency jump may induce a discontinuity in the average longitudinal force per focusing period and shrink the longitudinal acceptance of the linac if this transition is not performed carefully. In this paper, three techniques are developed which produce a “certain” continuity of the channel at the transition between. The continuity type is discussed. It is demonstrated that the longitudinal acceptance can be preserved whatever the frequencies of the cavities in the linac. This point is very important when comparisons between different cavity types are made (spoke and elliptical cavities for, instance. A few examples are shown to illustrate the performances of the three techniques.

  18. The Linac Cooherent Light Source (LCLS) Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Juhao; Emma, P.; /SLAC

    2007-03-21

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

  19. Stabilization Strategies for Drift Tube Linacs

    CERN Document Server

    AUTHOR|(CDS)2085420; Lamehi Rashti, Mohammad

    The average axial electric fields in drift tube linac cavities are known to be sensitive with respect to the perturbation errors. Postcoupler is a powerful stabilizer devices that is used to reduce this sensitivity of average axial field. Postcouplers are the cylindrical rod which is extended from cavity wall toward the drift tube without touching the drift tube surface. Postcouplers need to be adjusted to the right length to stabilize the average axial field. Although postcouplers are used successfully in many projects, there is no straightforward procedure for postcouplers adjustment and it has been done almost based on trial and errors. In this thesis, the physics and characteristics of postcouplers has been studied by using an equivalent circuit model and 3D finite element method calculations. Finally, a straightforward and accurate method to adjust postcouplers has been concluded. The method has been verified by using experimental measurements on CERN Linac4 drift tube linac cavities.

  20. Beam lines from Linac 1 and Linac 2 to the Booster

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    View against the direction of the beams. Both Linacs are behind the concrete wall at the back of the picture. The 50 MeV proton beam from Linac 1 enters the PS tunnel through the hole at left. The line from Linac 2, in the process of being installed, comes from the hole at right. The lines converge at a switching magnet (prominently in the foreground), which selects which of the 2 beams to send on to the Booster. See also 7802261 and further explanations there.

  1. On the Feasibility of Accelerating Deuterons in Linac4

    CERN Document Server

    Stovall, J; Garcia Tudela, M; Ramberger, S; Crandall, K

    2011-01-01

    The Linac4 normal-conducting linac is comprised of three sections, DTL, CCDTL and PIMS. It is designed to accelerate H-minus ions to a final energy of 160 MeV. The objective of this study is to investigate the feasibility of accelerating deuterons in this linac for injection into the PS Booster.

  2. 4-rod RFQ linac for ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, Hiroshi; Hamamoto, Nariaki; Inouchi, Yutaka [Nisshin Electric Co. Ltd., Kyoto (Japan)

    1997-03-01

    A 34 MHz 4-rod RFQ linac system has been upgraded in both its rf power efficiency and beam intensity. The linac is able to accelerate in cw operation 0.83 mA of a B{sup +} ion beam from 0.03 to 0.91 MeV with transmission of 61 %. The rf power fed to the RFQ is 29 kW. The unloaded Q-value of the RFQ has been improved approximately 61 % to 5400 by copper-plating stainless steel cooling pipes in the RFQ cavity. (author)

  3. Preinjector for Linac 1, accelerating column

    CERN Multimedia

    1974-01-01

    For a description of the Linac 1 preinjector, please see first 7403070X. High up on the wall of the Faraday cage (7403073X) is this drum-shaped container of the ion source (7403083X). It is mounted at the HV end of the accelerating column through which the ions (usually protons; many other types of ions in the course of its long history) proceed through the Faraday cage wall to the low-energy end (at ground potential) of Linac 1. The 520 kV accelerating voltage was supplied by a SAMES generator (7403074X).

  4. Simulation of Redox-Cycling Phenomena at Interdigitated Array (IDA) Electrodes: Amplification and Selectivity

    NARCIS (Netherlands)

    Odijk, Mathieu; Olthuis, Wouter; Dam, T.V.A.; van den Berg, Albert

    2008-01-01

    We present Finite Element Method (FEM) simulations of interdigitated array (IDA) electrode geometries to study and verify redox selectivity and redox cycling amplification factor. The simulations provide an adequate explanation of an earlier found, but poorly understood, high amplification factor

  5. Interdigitation of long-chain sphingomyelin induces coupling of membrane leaflets in a cholesterol dependent manner

    DEFF Research Database (Denmark)

    Róg, Tomasz; Orłowski, Adam; Llorente, Alicia

    2016-01-01

    It has been a long-standing question how the two leaflets in a lipid bilayer modulate each others' physical properties. In this paper, we discuss how this interaction may take place through interdigitation. We use atomistic molecular dynamics simulations to consider asymmetric lipid membrane mode......, and that cholesterol modulates the effect of SM interdigitation by influencing the conformational order of lipid hydrocarbon chains in the opposing (cytosolic) leaflet....

  6. Preparation, Applications, and Digital Simulation of Carbon Interdigitated Array Electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Fei; Kolesov, Grigory; Parkinson, Bruce A.

    2014-12-16

    Carbon interdigitated array (IDA) electrodes with features sizes down to 1.2 μm were fabricated by controlled pyrolysis of patterned photoresist. Cyclic voltam-metry of reversible redox species produced the expected steady-state currents. The collection efficiency depends on the IDA electrode spacing, which ranged from around 2.7 to 16.5 μm, with the smaller dimensions achieving higher collection efficiencies of up to 98%. The signal amplification because of redox cycling makes it possible to detect species at relatively low concentrations (10–5 molar) and the small spacing allows detection of transient electrogenerated species with much shorter lifetimes (submillisecond). Digital simulation software that accounts for both the width and height of electrode elements as well as the electrode spacing was developed to model the IDA electrode response. The simulations are in quantitative agreement with experimental data for both a simple fast one electron redox reaction and an electron transfer with a following chemical reaction at the IDAs with larger gaps whereas currents measured for the smallest IDA electrodes, that were larger than the simulated currents, are attributed to convection from induced charge electrokinetic flow. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the Department of Energy, Office of Science Office of Basic Energy Sciences.

  7. Basic characteristics of quartz crystal sensor with interdigitated electrodes

    Directory of Open Access Journals (Sweden)

    Hiroshi Muramatsu

    2016-03-01

    Full Text Available This paper describes basic characteristics of the quartz crystal sensor with interdigitated electrodes (IDE quartz crystal sensor which is for simultaneous monitoring of mass, viscosity, conductivity and dielectric changes of liquids or thin films. As the IDE quartz crystal sensor has three terminals for a pair of IDEs on the one side and a counter electrode on the other side, the resonance properties have been analyzed using the electrical equivalent circuit models and measured experimentally for all connecting types of electrode pairs. The IDE quartz crystal has shown clear resonance curves for calculating the resonance frequency and resonance resistance values as well as normal quartz crystal in the air and in contact with liquid. Small shifts in the resonance frequency and resonance resistance depending on the connecting types have been obtained and analyzed using the equivalent circuit models. We have found the integrated quartz crystal and IDE sensors could be monitored simultaneously by only one impedance analyzer. Finally, two types of measuring systems have been demonstrated for continuous measuring methods.

  8. Amphotericin B induced interdigitation of apolipoprotein stabilized nanodisk bilayers

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T; Weers, P M; Sulchek, T; Hoeprich, P D; Ryan, R O

    2006-12-07

    Amphotericin B nanodisks (AMB-ND) are ternary complexes of AMB, phospholipid (PL) and apolipoprotein organized as discrete nanometer scale disk-shaped bilayers. In gel filtration chromatography experiments, empty ND lacking AMB elute as a single population of particles with a molecular weight in the range of 200 kDa. AMB-ND formulated at a 4:1 PL:AMB weight ratio, separated into two peaks. Peak 1 eluted at the position of control ND lacking AMB while the second peak, containing all of the AMB present in the original sample, eluted in the void volume. When ND prepared with increased AMB (1:1 phospholipid:AMB molar ratio) were subjected to gel filtration chromatography, an increased proportion of phospholipid and apolipoprotein were recovered in the void volume with the AMB. Prior to gel filtration the AMB-ND sample could be passed through a 0.22 {micro}m filter without loss of AMB while the voided material was lost. Native gel electrophoresis studies corroborated the gel permeation chromatography data. Far UV circular dichroism analyses revealed that apoA-I associated with AMB-ND denatures at a lower guanidine HCl concentration than apoA-I associated with ND lacking AMB. Atomic force microscopy revealed that AMB induces compression of the ND bilayer thickness consistent with bilayer interdigitation, a phenomenon that is likely related to the ability of AMB to induce pore formation in susceptible membranes.

  9. Fabrication of Silver Interdigitated Electrode by a Stamp Method

    Directory of Open Access Journals (Sweden)

    Kan-Sen Chou

    2014-01-01

    Full Text Available A stamp method was developed in this study to fabricate interdigitated electrodes (IDEs on glass substrate from a 37.5 wt% silver ink. This method is simple and fast. A small amount of silver ink was first dripped into an IDE-patterned sponge of a stamp and then one could stamp out the desired IDE pattern made of nanosized silver colloids on a glass substrate, which was subsequently sintered at 280°C for 10 minutes to obtain the final silver IDE. Our brief study showed that when a large stamping force was used, more ink would be stamped out in the beginning and it decreased after each usage. However, if the force was too small, there would not be sufficient ink for a complete IDE. There existed therefore an optimal force to fabricate IDEs with minimal changes from sample to sample. The average dimension of an IDE when the applied force was 102 gm was roughly 403 ± 20 µm in width and 1154 ± 153 nm in height, and the average final electrical resistivity was about 10×10-6 Ω-cm.

  10. Hygroscopic particle behavior studied by interdigitated array microelectrode impedance sensors.

    Science.gov (United States)

    Schindelholz, Eric; Tsui, Lok-kun; Kelly, Robert G

    2014-01-09

    The hygroscopic behavior of soluble salts bears importance in many research fields including atmospheric sciences, corrosion, porous building materials, and pharmaceuticals. Several methods have been used to study deliquescence (solid to liquid) and efflorescence (liquid to solid) phase transitions of these salts. In this study, we measured the deliquescence and efflorescence RH values of single salt microparticles deposited on an interdigitated microelectrode sensor via electrical impedance. The salts examined were NaCl, LiCl, NaBr, KCl, and MgCl2. Measured values were in agreement with in situ optical microscopic observations and, with the exception of MgCl2, literature values. In the case of MgCl2, deliquescence occurred at 33% RH and 12-15% RH, with the latter range being previously unreported. The depressed deliquescence RH was hypothesized to be a result of the formation of a metastable MgCl2 hydrate. Incomplete efflorescence of MgCl2 was also observed after exposure to hygroscopic particles.

  11. Femtosecond laser ablation of gold interdigitated electrodes for electronic tongues

    Science.gov (United States)

    Manzoli, Alexandra; de Almeida, Gustavo F. B.; Filho, José A.; Mattoso, Luiz H. C.; Riul, Antonio; Mendonca, Cleber R.; Correa, Daniel S.

    2015-06-01

    Electronic tongue (e-tongue) sensors based on impedance spectroscopy have emerged as a potential technology to evaluate the quality and chemical composition of food, beverages, and pharmaceuticals. E-tongues usually employ transducers based on metal interdigitated electrodes (IDEs) coated with a thin layer of an active material, which is capable of interacting chemically with several types of analytes. IDEs are usually produced by photolithographic methods, which are time-consuming and costly, therefore, new fabrication technologies are required to make it more affordable. Here, we employed femtosecond laser ablation with pulse duration of 50 fs to microfabricate gold IDEs having finger width from 2.3 μm up to 3.2 μm. The parameters used in the laser ablation technique, such as light intensity, scan speed and beam spot size have been optimized to achieve uniform IDEs, which were characterized by optical and scanning electron microscopy. The electrical properties of gold IDEs fabricated by laser ablation were evaluated by impedance spectroscopy, and compared to those produced by conventional photolithography. The results show that femtosecond laser ablation is a promising alternative to conventional photolithography for fabricating metal IDEs for e-tongue systems.

  12. Trehalose-induced destabilization of interdigitated gel phase in dihexadecylphosphatidylcholine.

    Science.gov (United States)

    Takahashi, H; Ohmae, H; Hatta, I

    1997-01-01

    Trehalose is believed to have the ability to protect some organisms against low temperatures. To clarify the cryoprotective mechanism of trehalose, the structure and the phase behavior of fully hydrated dihexadecylphosphatidylcholine (DHPC) membranes in the presence of various concentrations of trehalose were studied by means of differential scanning calorimetry (DSC), static x-ray diffraction, and simultaneous x-ray diffraction and DSC measurements. The temperature of the interdigitated gel (Lbeta(i))-to-ripple (Pbeta') phase transition of DHPC decreases with a rise in trehalose concentration up to approximately 1.0 M. Above a trehalose concentration of approximately 1.0 M, no Lbeta(i) phase is observed. In this connection, the electron density profile calculated from the lamellar diffraction data in the presence of 1.6 M trehalose indicates that DHPC forms noninterdigitated bilayers below the P beta' phase. It was concluded that trehalose destabilizes the Lbeta(i) phase of DHPC bilayers. This suggests that trehalose reduces the area at the interface between the lipid and water. The relation between this effect of trehalose and a low temperature tolerance was discussed from the viewpoint of cold-induced denaturation of proteins. PMID:9414217

  13. Interdigitated array microelectrode capacitive sensor for detection of paraffinophilic mycobacteria

    Science.gov (United States)

    Sampson, Andrew M.; Peterson, Erik T. K.; Papautsky, Ian

    2008-02-01

    Mycobacterium Avium Complex (MAC) is an opportunistic pathogen that threatens public health and has high clinical relevance. While culture-based and molecular biology techniques for identification are available, these methods are prone to error and require weeks to perform. There is a critical need for improved portable lab-on-a-chip sensor technology which will enable accurate and rapid point-of-care detection of these microorganisms. In this work, a new capacitive sensing strategy is explored utilizing interdigitated array (IDA) microelectrodes and exploiting the paraffinophilic nature of MAC. In this approach, paraffin wax is deposited over IDA microelectrodes to selectively extract these microorganisms from samples. As bacteria consume the dielectric paraffin layer, the charging current of the IDA capacitor changes to facilitate detection. Several IDA geometries were designed and simulated using CFD-ACE+ modeling software and compared with mathematical models. Capacitance of fabricated devices was determined using a charge-based capacitance measurement (CBCM) technique. Modeling and experimental results were in good agreement. Detection of femto-Farad changes in capacitance is possible, making this a feasible technique for sensing small changes in the paraffin for detection of paraffinophilic MAC.

  14. First beam in Linac4 DTL

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    Following the installation of the Linac4 Drift Tube Linac (DTL) earlier this summer (see here), the first DTL tank saw beams at 12 MeV on 5 August.   Transverse emittance measured at 12 MeV after the DTL tank1 using a temporary slit-and-grid emittance device. You never forget your first beam. That was especially true for the Linac4 DTL team, as it followed years of design, construction and vigorous testing. "We performed countless measurements of the geometry, vacuum and magnet polarisation of the DTL tanks while we were in the workshop," says Suitbert Ramberger, project engineer for the Linac4 DTL. "Add that preparation to the excellent RF conditioning that we carried out in the weeks before the beam tests and I was confident that the acceleration with beam would fully meet expectations!" Indeed it did. Beam commissioning tests ran until 21 August and found the DTL operating with nominal transmission. This successful run has confirmed the innovative design ...

  15. Vibrational Stability of NLC Linac Accelerating Structure

    CERN Document Server

    Le Pimpec, F; Bowden, G B; Doyle, E; McKee, B; Seryi, Andrei; Redaelli, S; Adiga, S

    2002-01-01

    The vibration of components of the NLC linac, such as accelerating structures and girders, is being studied both experimentally and analytically. Various effects are being considered including structural resonances and vibration caused by cooling water in the accelerating structure. This paper reports the status of ongoing work.

  16. Preinjector for Linac 1, SAMES generator

    CERN Multimedia

    1974-01-01

    For a description of the Linac 1 preinjector, please see first 7403070x. When the original 520 kV Cockcroft-Walton generator broke down in 1973, it was replaced by this much smaller 520 kV SAMES generator, seen here sitting on the floor of the Faraday cage.

  17. Design of post linac to driver linac transport beam line in rare isotope accelerator.

    Science.gov (United States)

    Kim, Chanmi; Kim, Eun-San

    2015-07-01

    We investigated the design of a beam transport line connecting the post linac to the driver linac (P2DT) in the Rare Isotope Accelerator (RAON). P2DT beam line is designed by 180° bending scheme to send the radioactive isotope separation on-line (ISOL) beams accelerated in the Linac-3 to Linac-2. The beam line is designed as a 180° bend for the transport of a multi-charge state (132)Sn(+45,+46,+47) beam. We used the TRACE 3-D, TRACK, and ORBIT codes to design the optics system, which also includes two bunchers and ten sextupole magnets for chromaticity compensation. The transverse emittance growth is minimized by adopting mirror symmetric optics and by correcting second-order aberrations using sextupoles. We report on the multi-charge state beam transport performance of the designed beam line. The main characteristics of the P2DT line are to minimize beam loss and the growth of emittance, and for charge stripping. Beam optics for P2DT is optimized for reducing beam loss and charge stripping. As Linac-3 may accelerate the stable beam and radioactive beam simultaneously, P2DT line also transports the stable beam and radioactive beam simultaneously. Thus, we need a RF switchyard to send the stable beam to the ISOL target and the radioactive beam to the high-energy experimental area in Linac-2 end.

  18. Argonne superconducting heavy-ion linac

    Energy Technology Data Exchange (ETDEWEB)

    Bollinger, L.M.; Benaroya, R.; Clifft, B.E.; Jaffey, A.H.; Johnson, K.W.; Khoe, T.K.; Scheibelhut, C.H.; Shepard, K.W.; Wangler, Y.Z.

    1976-01-01

    A summary is given of the status of a project to develop and build a small superconducting linac to boost the energy of heavy ions from an existing tandem electrostatic accelerator. The design of the system is well advanced, and construction of major components is expected to start in late 1976. The linac will consist of independently-phased resonators of the split-ring type made of niobium and operating at a temperature of 4.2/sup 0/K. The resonance frequency is 97 MHz. Tests on full-scale resonators lead one to expect accelerating fields of approximately 4 MV/m within the resonators. The linac will be long enough to provide a voltage gain of at least 13.5 MV, which will allow ions with A less than or approximately 80 to be accelerated above the Coulomb barrier of any target. The modular nature of the system will make future additions to the length relatively easy. A major design objective is to preserve the good quality of the tandem beam. This requires an exceedingly narrow beam pulse, which is achieved by bunching both before and after the tandem. Focusing by means of superconducting solenoids within the linac limit the radial size of the beam. An accelerating structure some 15 meters downstream from the linac will manipulate the longitudinal phase ellipse so as to provide the experimenter with either very good energy resolution (..delta..E/E approximately equal to 2 x 10/sup -4/) or very good time resolution (..delta.. t approximately equal to 30 psec).

  19. Fabrication, Tuning, Treatment and Testing of Two 3.5 Cell Photo-Injektor Cavities for the ELBE Linac

    CERN Document Server

    Arnold, A; Teichert, J; Xiang, R; Eremeev, G V; Kneisel, P; Stirbet, M; Turlington, L

    2011-01-01

    As part of a CRADA (Cooperative Research and Development Agreement) between Helmholtz-Zentrum Dresden-Rossendorf (HZDR) and Thomas Jefferson Lab National Accelerator Facility (TJNAF) we have fabricated and tested two 1.3 GHz 3.5 cell photo-injector cavities from polycrystalline RRR niobium and large grain RRR niobium, respectively. The cavity with the better performance will replace the presently used injector cavity in the ELBE linac [1]. The cavities have been fabricated and pre-tuned at TJNAF, while the more sophisticated final field tuning; the adjustment of the external couplings and the field profile measurement of transverse electric modes for RF focusing [2] was done at HZDR. The following standard surface treatment and the vertical test were carried out at TJNAF’s production facilities. A major challenge turned out to be the rinsing of the cathode cell, which has small opening (Ø10 mm) to receive the cathode stalk. Another unexpected problem encountered after etching, since large visible defects a...

  20. Resveratrol induces chain interdigitation in DPPC cell membrane model systems.

    Science.gov (United States)

    Longo, Elena; Ciuchi, Federica; Guzzi, Rita; Rizzuti, Bruno; Bartucci, Rosa

    2016-12-01

    Resveratrol is a natural polyphenol found in various plants with potential therapeutic activity as anti-oxidant, anti-inflammatory, cardioprotective and anti-tumoral. Lipid membranes are among cellular components that are targets of its action. In this work ESR of chain labeled lipids, calorimetry, X-ray diffraction and molecular docking are used to study the interaction of resveratrol with membrane model systems of dipalmitoylphosphatidylcholine (DPPC) as a function of resveratrol concentration (0-30 mol% of the lipid) and temperature (10-50°C). Resveratrol incorporated in DPPC bilayers induces considerable motional restriction at the lipid tail termini, removing the gradient of increasing mobility along the chain found in DPPC bilayers in the gel phase. In contrast, it leaves unperturbed the DPPC chain flexibility profile in the liquid-crystalline phase. At low concentration, resveratrol progressively reduces the pre-transition temperature and eliminates the pre-transition for content ≥5mol%. A reduced cooperativity and a downshift of the main transition temperature are observed, especially at high content. The typical diffraction pattern of DPPC multibilayers in the Lβ' phase is converted to a lamellar pattern with reduced d-spacing of untilted lipid chain in a hexagonal packing at 30 mol% of resveratrol. Molecular docking indicates that the energetically favoured anchoring site is the polar headgroup region, where resveratrol acts as a spacer. The overall results are consistent with the formation in DPPC of an interdigitated Lβi gel phase induced by 30 mol% resveratrol. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Investigation of bulk acoustic microwaves excited by an interdigital transducer

    Directory of Open Access Journals (Sweden)

    Reshotka O. G.

    2015-12-01

    Full Text Available Excitation of bulk and surface acoustic waves with the interdigital transducer (IDT, which is deposited on the surface of piezoelectric crystal, is widely used in the development of devices in acoustoelectronics and in the design of the microwave acousto-optic deflectors. Excitation of bulk acoustic waves by IDT in the devices on surface acoustic waves leads to the appearance of spurious signals. At the same time excitation of bulk acoustic waves with IDT from the surface of lithium niobate crystals allows creating high frequency acousto-optic deflectors, which makes possible to significantly simplify the technology of their production. Therefore, significant attention is paid to the task of excitation and distribution of bulk acoustic waves with IDT including recent times by the method of simulation of their excitation and distribution. The obtained theoretical results require experimental verification. This paper documents the visualization of acoustic beams excited with IDT from the XY-surface of lithium niobate crystals. The Bragg cells with LiNbO3 crystals coated with IDT with a different period of electrodes were manufactured for the experimental research of excitation and distribution of bulk acoustic waves. Visualization results have shown that the acoustic waves excited with IDT distribute in both the Fresnel zone and the Fraunhofer zone. The length of these zones is caused by individual elementary emitters of which consists the IDT (by their size. At the same time the far zone for IDT is located at distances much greater than the actual size of the LiNbO3 crystals. This peculiarity is not always taken into account when calculating diffraction. The achieved results can be used to design high-frequency acousto-optic devices, as well as in the development of devices based on surface acoustic waves.

  2. Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites.

    Science.gov (United States)

    Duan, Jinghao; Meng, Xiangjuan; Liu, Tonghai; Yin, Yong

    2016-06-17

    The aim of this study was to experimentally assess the dosimetric impact of leaf interdigitation using different inverse treatment strategies for representative tumour sites and to identify the situations in which leaf interdigitation can benefit these tumour sites. Sixty previously treated patients (15 nasopharyngeal carcinoma (NPC), 15 multiple brain metastasis (MBM), 15 cervical cancer and 15 prostate cancer) were re-planned for volumetric modulated arc therapy (VMAT), sliding window IMRT (dMLC) and step-and-shoot IMRT (ssIMRT) with and without leaf interdigitation. Various dosimetric variables, such as PTV coverage, OARs sparing, delivery efficiency and planning time, were evaluated for each plan. In addition, a protocol developed by our group was applied to identify the situations in which leaf interdigitation can achieve benefits in clinical practice. Leaf interdigitation produced few benefits in PTV homogeneity for the MBM VMAT plans and NPC ssIMRT plans. For OARs, sparing was equivalent with and without leaf interdigitation. Leaf interdigitation showed an increase in MUs for dMLC plans and a decrease in MUs for ssIMRT plans. Leaf interdigitation resulted in an increase in segments for dMLC plans and a decrease in segments for NPC and MBM ssIMRT plans. For beam on time, leaf interdigitation showed an increase in MBM dMLC, NPC ssIMRT and prostate ssIMRT plans. In addition, leaf interdigitation saved planning time for VMAT and dMLC plans but increased planning time for ssIMRT plans. Leaf interdigitation does not improve plan quality when performing inverse treatment strategies, regardless of whether the target is simple or complex. However, it influences the delivery efficiency and planning time. Based on these observations, our study suggests that leaf interdigitation should be utilized when performing MBM VMAT plans and NPC ssIMRT plans.

  3. High Current Energy Recovery Linac at BNL

    CERN Document Server

    Litvinenko, Vladimir N; Ben-Zvi, Ilan; Blaskiewicz, Michael; Bluem, Hans; Brennan, Joseph M; Burger, Al; Burrill, Andrew; Calaga, Rama; Cameron, Peter; Chang, Xiangyun; Cole, Michael; Connolly, Roger; Delayen, Jean R; Favale, Anthony; Gassner, David M; Hahn, Harald; Hershcovitch, Ady; Holmes, Douglas; Hseuh Hsiao Chaun; Johnson, Peter; Kayran, Dmitry; Kewisch, Jorg; Lambiase, Robert; Mahler, George; McIntyre, Gary; Meng, Wuzheng; Nehring, Thomas; Nicoletti, Tony; Oerter, Brian; Pate, David; Phillips, Larry; Preble, Joseph P; Rank, Jim; Rao, Triveni; Rathke, John; Roser, Thomas; Russo, Thomas; Scaduto, Joseph; Schultheiss, Tom; Smith, Kevin T; Todd, Alan M M; Warren Funk, L; Williams, Neville; Wu, Kuo-Chen; Yakimenko, Vitaly; Yip, Kin; Zaltsman, Alex; Zhao, Yongxiang

    2004-01-01

    We present the design and the parameters of a small Energy Recovery Linac (ERL) facility, which is under construction at BNL. This R&D facility has goals to demonstrate CW operation of ERL with average beam current in the range of 0.1 - 1 ampere, combined with very high efficiency of energy recovery. The possibility for future up-grade to a two-pass ERL is being considered. The heart of the facility is a 5-cell 703.75 MHz super-conducting RF linac with HOM damping. Flexible lattice of ERL provides a test-bed for testing issues of transverse and longitudinal instabilities and diagnostics of intense CW e-beam. We present the status and plans for this facility.

  4. A Superconducting Linac for the Energy Amplifier

    Science.gov (United States)

    Ruggiero, A. G.

    1997-05-01

    Because of the safer and more reliable mode of operation, a Superconducting Linac is proposed here as the proton beam accelerator which drives a nuclear plant based on the concept of the Energy Amplifier. The accelerator has also high electric power efficiency, estimated around 40%. An example based on the net generation of 400 MW (electric) is described here. This requires a proton beam energy of 1 GeV with a continuous beam current of 10 mA, corresponding to a beam power of 10 MW. The study compares the cost and performance of several rf cavity frequencies, namely 350 versus 800 MHz. Higher power values can be obtained with larger beam energy and intensity. A re-circulation configuration mode of the Linac is also proposed and studied.

  5. High Current Energy Recovery Linac at BNL

    Energy Technology Data Exchange (ETDEWEB)

    Vladimir N. Litvinenko; Donald Barton; D. Beavis; Ilan Ben-Zvi; Michael Blaskiewicz; J.M. Brennan; A. Burrill; R. Calaga; P. Cameron; X. Chang; Roger Connolly; D. Gassner; H. Hahn; A. Hershcovitch; H.C. Hseuh; P. Johnson; D. Kayran; J. Kewisch; R. Lambiase; G. McIntyre; W. Meng; T. C. Nehring; A. Nicoletti; D. Pate; J. Rank; T. Roser; T. Russo; J. Scaduto; K. Smith; T. Srinivasan-Rao; N. Williams; K.-C. Wu; Vitaly Yakimenko; K. Yip; A. Zaltsman; Y. Zhao; H. Bluem; A. Burger; Mike Cole; A. Favale; D. Holmes; John Rathke; Tom Schultheiss; A. Todd; J. Delayen; W. Funk; L. Phillips; Joe Preble

    2004-08-01

    We present the design, the parameters of a small test Energy Recovery Linac (ERL) facility, which is under construction at Collider-Accelerator Department, BNL. This R&D facility has goals to demonstrate CW operation of ERL with average beam current in the range of 0.1 - 1 ampere, combined with very high efficiency of energy recovery. A possibility for future up-grade to a two-pass ERL is considered. The heart of the facility is a 5-cell 700 MHz super-conducting RF linac with HOM damping. Flexible lattice of ERL provides a test-bed for testing issues of transverse and longitudinal instabilities and diagnostics of intense CW e-beam. ERL is also perfectly suited for a far-IR FEL. We present the status and our plans for construction and commissioning of this facility.

  6. LINAC4 takes a tour of Europe

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Along the German Autobahnen, a truck carrying 20 tonnes of copper is on its way to Poland. The metal has already made a short tour of Europe, yet the drive across the high-speed highway is only the beginning of its transformation into CERN’s next linear accelerator, LINAC4.   Grzegorz Wrochna (left), director of the Andrzej Soltan Institute for Nuclear Studies (IPJ), and Rolf Heuer (right), CERN DG, sign the framework agreement between the two institutes. By the summer of 2012, the PI-Mode Structures (PIMS) will be constructed and completely installed in the LINAC4 tunnel. The PIMS cavities are the final accelerating structures needed for LINAC4, and have been designed to accelerate protons from 100 to 160MeV. While the first cavity was built entirely at CERN, construction of the remaining cavities has become a larger, multi-national operation. In a 1 million euro framework agreement signed on 11 February by the Director-General, the Andrzej Soltan Institute for Nuclear Studies in Swie...

  7. Status of Linac4 construction at CERN

    CERN Document Server

    Vretenar, M

    2010-01-01

    Linac4 is a 160 MeV normal-conducting H¯ linear accelerator which is being built at CERN in the frame of a program for increasing the luminosity of the LHC. The project started in 2008 and delivery of beam to the CERN accelerator chain is foreseen from early 2015. The new linac will be housed in an underground tunnel close to the present Linac2; a surface building will house RF and other infrastructure. The civil engineering work started in October 2008 will be soon completed. Installation of the infrastructure will take place in 2011, and from 2012 will be installed the main machine elements. The ion source is presently operational on a test stand, where it will be followed in 2011 by a 3 MeV RFQ under construction in the CERN workshops. Prototypes of the three different types of accelerating structures have been tested; construction of the 22 accelerating cavities has started, supported by a network of agreements with external laboratories and institutions. Commissioning will take place in stages, starting...

  8. Future developments in electron linac diagnostics

    CERN Document Server

    Ross, M C

    2004-01-01

    The next generation of electron linacs will fill two different roles: ultra-low emittance, very high power accelerators for linear colliders and ultra-short bunch, high stability accelerators for SASE X-ray production. In either case, precision control based on non-invasive, reliable, beam instrumentation will be required. For the linear collider, low emittance transport is an important concern for both warm and superconducting linacs. Instrumentation will be used to control and diagnostics will be used to validate emittance preserving strategies, such as beam based alignment and dispersion - free steering. Tests at the KEK ATF and the SLAC FFTB have demonstrated the required performance for beam position and beam size monitors. Linacs intended for FEL's will require precision bunch length diagnostics because of expected non-linear micro-bunching processes. A wide variety of devices are now in development at FEL prototypes, including TTF2 at DESY and SPPS at SLAC. We present a review of the new diagnostic ...

  9. Preinjector for Linac 1, Faraday cage

    CERN Multimedia

    1974-01-01

    The 50 MeV Linac 1 started up in 1958 as injector to the 26 GeV PS, with a 520 kV Cockcroft-Walton generator as its preinjector, housed in a vast Faraday cage, visible here. When the Cockcroft-Walton broke down in 1973, it was replaced by a much smaller SAMES generator, of the kind used for electrostatic separators. From 1980 on, Linac 2 took over as injector for the 800 MeV Booster, and Linac 1 continued as injector for LEAR. In 1984, the electrostatic preinjector (i.e. the Faraday cage with its contents, SAMES generator and all) was replaced by a 520 keV RFQ. At the lower left corner we see the HV connectors to the SAMES generator, at the right edge part of the opened electronics-platform. Jean-Luc Vallet sees to it that all parts are properly grounded. See also 7403073X, 7403074X, 7403081X, 7403083X.

  10. Linac4: the final assembly stage is under way

    CERN Multimedia

    CERN Bulletin

    2013-01-01

    The Linac4 radiofrequency quadrupole (RFQ) module was installed at the accelerator test-stand in Building 152 last August. After an assembly phase and tests that concluded last March with the acceleration of a hydrogen beam to 3 MeV, the module has just been permanently installed in the new Linac4 tunnel (Building 400). The installation of the MEBT (Medium Energy Beam Transport) will begin shortly, followed by the start of the first Linac4 commissioning phase.     To find out more about the Linac4 RFQ module, read the previous Bulletin articles published in Nos. 21-22/2010 and 35-36/2012.

  11. Oxygen ion source and RFQ for Linac 1

    CERN Multimedia

    Photographic Service

    1986-01-01

    As injector to the PS Booster, Linac 1 was replaced by Linac 2 in 1980. It continued to be used for the acceleration of oxygen and sulfur ions. In 1984, its Cockcroft-Walton preinjector was replaced by an RFQ. In the foreground at the right is the oxygen ion source. A 90 deg bending magnet selects O6+ ions which are preaccelerated in an RFQ and enter Linac 1, at the far left. In the background is the proton and negative hydrogen ion source, followed by the 520 keV RFQ-1 and a bending magnet towards the entrance of Linac 1.

  12. Crossbar H-mode drift-tube linac design with alternative phase focusing for muon linac

    Science.gov (United States)

    Otani, M.; Futatsukawa, K.; Hasegawa, K.; Kitamura, R.; Kondo, Y.; Kurennoy, S.

    2017-07-01

    We have developed a Crossbar H-mode (CH) drift-tube linac (DTL) design with an alternative phase focusing (APF) scheme for a muon linac, in order to measure the anomalous magnetic moment and electric dipole moment (EDM) of muons at the Japan Proton Accelerator Research Complex (J-PARC). The CH-DTL accelerates muons from β = v/c = 0.08 to 0.28 at an operational frequency of 324 MHz. The design and results are described in this paper.

  13. Low-frequency and wideband vibration energy harvester with flexible frame and interdigital structure

    Energy Technology Data Exchange (ETDEWEB)

    Li, Pengwei, E-mail: lipengwei@tyut.edu.cn; Wang, Yanfen; Luo, Cuixian; Li, Gang; Hu, Jie; Zhang, Wendong [MicroNano System Research Center of College of Information Engineering and Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, Shanxi (China); Liu, Ying [MicroNano System Research Center of College of Information Engineering and Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, Shanxi (China); Baicheng Ordnance Test Center of China, Baicheng 137000, Jilin (China); Liu, Wei [Baicheng Ordnance Test Center of China, Baicheng 137000, Jilin (China)

    2015-04-15

    As an alternative to traditional cantilever beam structures and their evolutions, a flexible beam based, interdigital structure, vibration energy harvester has been presented and investigated. The proposed interdigital-shaped oscillator consists of a rectangular flexible frame and series of cantilever beams interdigitally bonded to it. In order to achieve low frequency and wide-bandwidth harvesting, Young’s modulus of materials, frame size and the amount of the cantilevers have been studied systematically. The measured frequency responses of the designed device (PDMS frame, quintuple piezoelectric cantilever beams) show a 460% increase in bandwidth below 80Hz. When excited at an acceleration of 1.0 g, the energy harvester achieves to a maximum open-circuit voltage of 65V, and the maximum output power 4.5 mW.

  14. Study on band gap characteristics of EBG structures with interdigital and spiral ground plane

    Science.gov (United States)

    Huang, Weili; Wu, Zhaohua

    2017-10-01

    In order to solve the problem that the resonant frequency is too high and the structure is too large when the traditional electromagnetic band gap (EBG) structure is used in the microwave circuit. The paper is based on the equivalent theory of microwave circuit, and an EBG structure with spiral ground plane and interdigital structure is designed. In th e range of 1-10 GHz, interdigitated EBG, spiral ground EBG and interdigitated spiral ground EBG were analyzed by HFSS software. The S21 parameters were obtained and compared with each other. The results show that the band gap frequency of the three structures is 4.8GHz, 2.8GHz and 1.85GHz respectively under the same size.

  15. Low-frequency and wideband vibration energy harvester with flexible frame and interdigital structure

    Directory of Open Access Journals (Sweden)

    Pengwei Li

    2015-04-01

    Full Text Available As an alternative to traditional cantilever beam structures and their evolutions, a flexible beam based, interdigital structure, vibration energy harvester has been presented and investigated. The proposed interdigital-shaped oscillator consists of a rectangular flexible frame and series of cantilever beams interdigitally bonded to it. In order to achieve low frequency and wide-bandwidth harvesting, Young’s modulus of materials, frame size and the amount of the cantilevers have been studied systematically. The measured frequency responses of the designed device (PDMS frame, quintuple piezoelectric cantilever beams show a 460% increase in bandwidth below 80Hz. When excited at an acceleration of 1.0 g, the energy harvester achieves to a maximum open-circuit voltage of 65V, and the maximum output power 4.5 mW.

  16. Flow maldistribution in the anode of a polymer electrolyte membrane electrolysis cell employing interdigitated channels

    DEFF Research Database (Denmark)

    Olesen, Anders Christian; Kær, Søren Knudsen

    2014-01-01

    of liquid water towards the catalytic layer of the electrode. As opposed to the more common serpentine and parallel channels, interdigitated channels force liquid water through the porous gas diffusion layer (GDL) of the electrode. This improves the supply of water, however it increases pressure losses......In this work a macroscopic, steady-state, three-dimensional, computational fluid dynamics model of the anode of a high-pressure polymer electrolyte membrane electrolysis cell (PEMEC) is presented. The developed model is used for studying the effect of employing an interdigitated, planar......-circular cell design on the distribution of water in the anode. In the electrolysis of water using PEMEC the anode is fed by demineralized water. Throughout the anode, oxygen is produced and a two-phase flow develops. Interdigitated channels assist in avoiding that gaseous oxygen obstructs the transport...

  17. Commercial Superconducting Electron Linac for Radioisotope Production

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Terry Lee [Niowave, Inc., Lansing, MI (United States); Boulware, Charles H. [Niowave, Inc., Lansing, MI (United States); Hollister, Jerry L. [Niowave, Inc., Lansing, MI (United States); Jecks, Randall W. [Niowave, Inc., Lansing, MI (United States); Mamtimin, Mayir [Niowave, Inc., Lansing, MI (United States); Starovoitova, Valeriia [Niowave, Inc., Lansing, MI (United States)

    2015-08-13

    The majority of radioisotopes used in the United States today come from foreign suppliers or are generated parasitically in large government accelerators and nuclear reactors. Both of these restrictions limit the availability of radioisotopes and discourage the development and evaluation of new isotopes and for nuclear medicine, science, and industry. Numerous studies have been recommending development of dedicated accelerators for production of radioisotopes for over 20 years (Institute of Medicine, 1995; Reba, et al, 2000; National Research Council, 2007; NSAC 2009). The 2015 NSAC Long Range Plan for Isotopes again identified electron accelerators as an area for continued research and development. Recommendation 1(c) from the 2015 NSAC Isotope report specifically identifies electron accelerators for continued funding for the purpose of producing medical and industrial radioisotopes. Recognizing the pressing need for new production methods of radioisotopes, the United States Congress passed the American Medical Isotope Production Act of 2012 to develop a domestic production of 99Mo and to eliminate the use of highly enriched uranium (HEU) in the production of 99Mo. One of the advantages of high power electron linear accelerators (linacs) is they can create both proton- and neutron-rich isotopes by generating high energy x-rays that knock out protons or neutrons from stable atoms or by fission of uranium. This allows for production of isotopes not possible in nuclear reactors. Recent advances in superconducting electron linacs have decreased the size and complexity of these systems such that they are economically competitive with nuclear reactors and large, high energy accelerators. Niowave, Inc. has been developing a radioisotope production facility based on a superconducting electron linac with liquid metal converters.

  18. Towards breast cancer radiotherapy on the MRI-linac

    NARCIS (Netherlands)

    van Heijst, TCF

    2017-01-01

    With the introduction of the magnetic resonance imaging (MRI)-linear accelerator (linac) at University Medical Center Utrecht, on-line MRI guidance for radiation therapy (RT) treatments is possible. This PhD thesis explores technical implementation of the MRI-linac for local and regional breast

  19. MEIC Proton Beam Formation with a Low Energy Linac

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuhong [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    The MEIC proton and ion beams are generated, accumulated, accelerated and cooled in a new green-field ion injector complex designed specifically to support its high luminosity goal. This injector consists of sources, a linac and a small booster ring. In this paper we explore feasibility of a short ion linac that injects low-energy protons and ions into the booster ring.

  20. Development of an Eddy Current Septum for LINAC4

    CERN Document Server

    Barnes, M; Borburgh, J; Fowler, T; Goddard, B; Ueda, A; Weterings, W

    2008-01-01

    A linear accelerator (linac) is the first stage of the CERN accelerator complex. The linac defines the beam quality for subsequent stages of acceleration and the reliability has to be high as a fault of the linac shuts down all other machines. The existing linacs at CERN were designed 30 or more years ago: recent upgrades allowed the linacs to reach LHC requirements but also showed that they are at the limit of their brightness and intensity capabilities. A replacement Superconducting Proton Linac (SPL) has been proposed; the initial part of the SPL is termed LINAC4. The LINAC4 injection bump would be made up of a set of four pulsed dipole magnets; the first of these magnets (BS1) must act as a septum with a thin element dividing the high-field region of the circulating beam from the field-free region through which injected $H^{-}$ beam must pass. The initial specifications for BS1 required; a deflection of 66 mrad at 160 MeV, achieved with a peak field of 628 mT and a length of 250 mm: the field fall time wa...

  1. An overview of LINAC ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Roderich [Los Alamos National Laboratory

    2008-01-01

    This paper discusses ion sources used in high-duty-factor proton and H{sup -} Linacs as well as in accelerators utilizing multi-charged heavy ions, mostly for nuclear physics applications. The included types are Electron Cyclotron Resonance (ECR) sources as well as filament and rf driven multicusp sources. The paper does not strive to attain encyclopedic character but rather to highlight major lines of development, peak performance parameters and type-specific limitations and problems of these sources. The main technical aspects being discussed are particle feed, plasma generation and ion production by discharges, and plasma confinement.

  2. Range of Possible Beam Current in Linac4

    CERN Document Server

    Lallement, J-B; CERN. Geneva. BE Department

    2009-01-01

    Linac4 is a new accelerator under construction at CERN. It is designed to accelerate H- ions to 160MeV, for injection into the existing Proton Synchrotron Booster (PSB). It is also the front-end of the SPL Linac, a high energy proton driver that will reach the energy of 5GeV. The Linac baseline design has been done for a nominal beam peak current of 70mA but it will certainly have to deal with different currents. 132 out of 155 quadrupoles in the Linac are permanent magnets, this choice of using PMQ having fixed gradient, mainly in the DTL and in the CCDTL may then entail issues concerning the beam transverse matching and quality from current different from the nominal one. In this paper, we present the beam dynamics performances in Linac4 obtained for different currents.

  3. Photon and photoneutron spectra produced in radiotherapy Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Martinez O, S. A. [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, Av. Central del Norte Km. 1, Via Paipa Tunja, Boyaca (Colombia); Benites R, J. L. [Universidad Autonoma de Nayarit, Postgrado CBAP, Carretera Tepic Compostela Km. 9, Xalisco, Nayarit (Mexico); Lallena, A. M., E-mail: fermineutron@yahoo.com [Universida de Granada, Departamento de Fisica Atomica, Molecular y Nuclear, E-18071 Granada (Spain)

    2011-10-15

    A Monte Carlo calculation, using the MCNPX code, was carried out in order to estimate the photon and neutron spectra in two locations of two linacs operating at 15 and 18 MV. Detailed models of both linac heads were used in the calculations. Spectra were estimated below the flattening filter and at the isocenter. Neutron spectra show two components due to evaporation and knock-on neutrons. Lethargy spectra under the filter were compared to the spectra calculated from the function quoted by Tosi et al. that describes reasonably well neutron spectra beyond 1 MeV, though tends to underestimate the energy region between 10{sup -6} and 1 MeV. Neutron and Bremsstrahlung spectra show the same features regardless of the linac voltage. The amount of photons and neutrons produced by the 15 MV linac is smaller than that found for the 18 MV linac. As expected, Bremsstrahlung spectra ends according to the voltage used to accelerate the electrons. (Author)

  4. The Pre-Injector Linac for the Diamond Light Source

    CERN Document Server

    Christou, C

    2004-01-01

    The Diamond Light Source is a new medium-energy high brightness synchrotron light facility which is under construction on the Rutherford Appleton Laboratory site in the U.K. The accelerator facility can be divided into three major components; a 3 GeV 561 m circumference storage ring, a full-energy booster synchrotron and a 100 MeV pre-injector linac. This paper describes the linac design and plans for operation. The linac is supplied by ACCEL Instruments GmbH under a turn-key contract, with Diamond Light Source Ltd. providing linac beam diagnostics, control system hardware and standard vacuum components. Commissioning of the linac will take place in early 2005 and user operation of the facility will commence in 2007.

  5. Prussian Blue-coated interdigitated array electrodes for possible analytical application

    NARCIS (Netherlands)

    Hartmann, M.; Grabner, E.W.; Bergveld, Piet

    1991-01-01

    Thin films of iron(III) hexacyanoferrate(II) (Prussian Blue) were electrochemically deposited on interdigitated array (IDA) electrodes, yielding systems which can be considered as chemiresistors in sensing alkali metal ion concentrations in an adjacent electrolyte. This is due to the fact that the

  6. The interdigitated gel phase in mixtures of cationic and zwitterionic phospholipids.

    Science.gov (United States)

    Smith, Eric A; Dea, Phoebe K

    2015-01-01

    To examine the phase behavior of mixtures of zwitterionic and cationic lipids we used three derivatives of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC). All three lipids are uniquely capable of spontaneously forming the interdigitated gel phase (LβI) under typical hydration conditions. The P-O-ethyl derivative, 1,2-dipalmitoyl-sn-glycero-3-ethylphosphocholine (EDPPC), was chosen as the cationic lipid. For the zwitterionic lipids, we use the ether-linked 1,2-di-O-hexadecyl-sn-glycero-3-phosphocholine, (DHPC) and the fluorine substituted 1-palmitoyl-2-(16-fluoropalmitoyl)-sn-glycero-3-phosphocholine (F-DPPC). Differential scanning calorimetry (DSC) and fluorescence spectroscopy were used to analyze the lipid mixtures. The F-DPPC/EDPPC mixtures are interdigitated at all lipid ratios below the main transition temperature (Tm). In addition, EDPPC stabilizes the interdigitated gel phase of DHPC until the ripple gel phase (Pβ') is eliminated and only the LβI to liquid crystalline phase (Lα) main transition remains. These results demonstrate that mixtures of cationic and zwitterionic lipids can be compatible with the interdigitated phase. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. DNA damage precedes apoptosis during the regression of the interdigital tissue in vertebrate embryos

    Science.gov (United States)

    Montero, Juan A.; Sanchez-Fernandez, Cristina; Lorda-Diez, Carlos I.; Garcia-Porrero, Juan A.; Hurle, Juan M.

    2016-01-01

    DNA damage independent of caspase activation accompanies programmed cell death in different vertebrate embryonic organs. We analyzed the significance of DNA damage during the regression of the interdigital tissue, which sculpts the digits in the embryonic limb. Interdigit remodeling involves oxidative stress, massive apoptosis and cell senescence. Phosphorylation of H2AX mediated by ATM precedes caspase dependent apoptosis and cell senescence during interdigit regression. The association of γH2AX with other downstream DNA repair factors, including MDC1, Rad50 and 53BP1 suggests a defensive response of cells against DNA damage. The relative distribution of cells γH2AX-only positive, TUNEL-only positive, and cells double positive for both markers is consistent with a sequence of degenerative events starting by damage of the DNA. In support of this interpretation, the relative number of γH2AX-only cells increases after caspase inhibition while the relative number of TUNEL-only cells increases after inhibition of ATM. Furthermore, cultured interdigits survived and maintained intense chondrogenic potential, even at advanced stages of degeneration, discarding a previous commitment to die. Our findings support a new biological paradigm considering embryonic cell death secondary to genotoxic stimuli, challenging the idea that considers physiological cell death a cell suicide regulated by an internal death clock that pre-programmes degeneration. PMID:27752097

  8. Cement interdigitation and bone-cement interface after augmenting fractured vertebrae: A cadaveric study

    Science.gov (United States)

    Krüger, Antonio; Oberkircher, Ludwig; Kratz, Marita; Baroud, Gamal; Becker, Stephan; Ruchholtz, Steffen

    2012-01-01

    Background The treatment of painful osteoporotic vertebral compression fractures with transpedicular cement augmentation has grown significantly over the last 20 years. There is still uncertainty about long-term and midterm effects of polymethyl methacrylate in trabecular bone. Preservation of the trabecular structures, as well as interdigitation of the cement with the surrounding bone, therefore has been gaining increasing attention. Interdigitation of cement is likely relevant for biological healing and the biomechanical augmentation process. In this study a cutting and grinding technique was used to evaluate the interdigitation for 4 augmentation techniques. Methods By use of a standardized protocol, wedge fractures were created in vertebrae taken from a fresh-frozen spine. Thereafter the vertebrae were assigned to 1 of 4 similar groups with regard to the vertebral size and force required to produce the fracture. The 4 groups were randomized to the following augmentation techniques: balloon kyphoplasty, radiofrequency (RF) kyphoplasty, shield kyphoplasty, and vertebral stenting. Histologic analysis was designed to examine the bone structure and interdigitation after the augmentation. Results For the void-creating procedures, the distance between bone and cement was 341.4 ± 173.7 µm and 413.6 ± 167.6 µm for vertebral stenting and balloon kyphoplasty, respectively. Specifically, the trabecular bone was condensed around the cement, forming a shield of condensed bone. The procedures without a balloon resulted in shorter distances of 151.2 ± 111.4 µm and 228.1 ± 183.6 µm for RF and shield kyphoplasty, respectively. The difference among the groups was highly significant (P kyphoplasty, 20.5% ± 12.9% for vertebral stenting, 66.45% ± 12.35% for RF kyphoplasty, and 48.61% ± 20.56% for shield kyphoplasty. The difference among the groups was highly significant (P < .00001). Conclusions Cavity-creating procedures reduce the cement interdigitation significantly

  9. Beam commissioning for a superconducting proton linac

    Science.gov (United States)

    Wang, Zhi-Jun; He, Yuan; Jia, Huan; Dou, Wei-ping; Chen, Wei-long; Zhang, X. L.; Liu, Shu-hui; Feng, Chi; Tao, Yue; Wang, Wang-sheng; Wu, Jian-qiang; Zhang, Sheng-hu; Zhao, Hong-Wei

    2016-12-01

    To develop the next generation of safe and cleaner nuclear energy, the accelerator-driven subcritical (ADS) system emerges as one of the most attractive technologies. It will be able to transmute the long-lived transuranic radionuclides produced in the reactors of today's nuclear power plants into shorter-lived ones, and also it will provide positive energy output at the same time. The prototype of the Chinese ADS (C-ADS) proton accelerator comprises two injectors and a 1.5 GeV, 10 mA continuous wave (CW) superconducting main linac. The injector scheme II at the C-ADS demo facility inside the Institute of Modern Physics is a 10 MeV CW superconducting linac with a designed beam current of 10 mA, which includes an ECR ion source, a low-energy beam transport line, a 162.5 MHz radio frequency quadrupole accelerator, a medium-energy beam transport line, and a superconducting half wave resonator accelerator section. This demo facility has been successfully operating with an 11 mA, 2.7 MeV CW beam and a 3.9 mA, 4.3 MeV CW beam at different times and conditions since June 2014. The beam power has reached 28 kW, which is the highest record for the same type of linear accelerators. In this paper, the parameters of the test injector II and the progress of the beam commissioning are reported.

  10. Production of Medical Isotopes with Electron Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Rotsch, D A; Alford, K.; Bailey, J. L.; Bowers, D. L.; Brossard, T.; Brown, M. A.; Chemerisov, S. D.; Ehst, D.; Greene, J.; Gromov, R. G.; Grudzinski, J.J.; Hafenrichter, L.; Hebden, A. S.; Henning, W.; Heltemes, T. A.; Jerden, J.; Jonah, C. D.; Kalensky, M.; Krebs, J. F.; Makarashvili, V.; Micklich, B.; Nolen, J.; Quigley, K. J.; Schneider, J. F.; Smith, N. A.; Stepinski, D. C.; Sun, Z.; Tkac, P.; Vandegrift, G. F.; Virgo, M J; Wesolowski, K. A.; Youker, A. J.

    2017-06-01

    Radioisotopes play important roles in numerous areas ranging from medical treatments to national security and basic research. Radionuclide production technology for medical applications has been pursued since the early 1900s both commercially and in nuclear science centers. Many medical isotopes are now in routine production and are used in day-to-day medical procedures. Despite these advancements, research is accelerating around the world to improve the existing production methodologies as well as to develop novel radionuclides for new medical appli-cations. Electron linear accelerators (linacs) represent a unique method for the production of radioisotopes. Even though the basic technology has been around for decades, only recently have electron linacs capable of producing photons with sufficient energy and flux for radioisotope production become available. Housed in Argonne Nation-al Laboratory’s Low Energy Accelerator Facility (LEAF) is a newly upgraded 55 MeV/25-kW electron linear ac-celerator, capable of producing a wide range of radioiso-topes. This talk will focus on the work being performed for the production of the medical isotopes 99Mo (99Mo/99mTc generator), 67Cu, and 47Sc.

  11. RIA Superconducting Drift Tube Linac R & D

    Energy Technology Data Exchange (ETDEWEB)

    J. Popielarski; J. Bierwagen; S. Bricker; C. Compton; J. DeLauter; P. Glennon; T. Grimm; W. Hartung; D. Harvell; M. Hodek; M. Johnson; F. Marti; P. Miller; A. Moblo; D. Norton; L. Popielarski; J. Wlodarczak; R. C. York; A. Zeller

    2009-05-22

    Cavity and cryomodule development work for a superconducting ion linac has been underway for several years at the National Superconducting Cyclotron Laboratory. The original application of the work was the proposed Rare Isotope Accelerator. At present, the work is being continued for use with the Facility for Rare Isotope Beams (FRIB). The baseline linac for FRIB requires 4 types of superconducting cavities to cover the velocity range needed to accelerate an ion beam to 200 MeV/u: 2 types of quarter-wave resonator (QWR) and 2 types of half-wave resonator (HWR). Superconducting solenoids are used for focussing. Active and passive shielding is required to ensure that the solenoids’ field does not degrade the cavity performance. First prototypes of both QWR types and one HWR type have been fabricated and tested. A prototype solenoid has been procured and tested. A test cryomodule has been fabricated and tested. The test cryomodule contains one QWR, one HWR, one solenoid, and one super-ferric quadrupole. This report covers the design, fabrication, and testing of this cryomodule

  12. PHYSICS RESULTS OF THE NSLS-II LINAC FRONT END TEST STAND

    Energy Technology Data Exchange (ETDEWEB)

    Fliller R. P.; Gao, F.; Yang, X.; Rose, J.; Shaftan, T.; Piel, C

    2012-05-20

    The Linac Front End Test Stand (LFETS) was installed at the Source Development Laboratory (SDL) in the fall of 2011 in order to test the Linac Front End. The goal of these tests was to test the electron source against the specifications of the linac. In this report, we discuss the results of these measurements and the effect on linac performance.

  13. First Linac4 DTL & CCDTL cavities installed in tunnel

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    On 5 June, the first Drift Tube Linac (DTL) was successfully transported to its forever home in the Linac4 tunnel. Similarly, the first Cell-Coupled Drift Tube Linac (CCDTL) was installed on 6 June. These moves marked the end of years of design and manufacturing by Linac4 teams.   Although it may seem like a relatively routine transport operation, the DTL's move was a landmark event for the entire Linac4 collaboration. "Along with the first four Cell-Coupled DTL modules, which were installed on the following two working days, these are the first accelerating structures after front-end commissioning to be installed in the tunnel," says Frank Gerigk, who is responsible for all Linac4 accelerating structures. "It is a major milestone, because work on all these structures started well over a decade ago." The transport operation was also quite a victory for the Linac4 DTL team, whose journey to a complete DTL structure has been a bit of a wild ride. &qu...

  14. Linac4 crosses the 100 MeV threshold

    CERN Multimedia

    Corinne Pralavorio

    2016-01-01

    The new linear accelerator, which from 2020 will be the first link in the accelerator chain, has entered a new stage of its commissioning.   Members of the team in charge of the commissioning of Linac4 in the accelerator’s control room. A few hours earlier, Linac4 accelerated a beam to 107 MeV for the first time. We couldn’t have imagined a more appropriate date: on 1 July (1.07), Linac4 reached an energy of 107 MeV. Having crossed the 100 MeV barrier, the linear accelerator is now on the home straight of its commissioning. “This stage was very quick – it took less than two weeks,” says Alessandra Lombardi, deputy project leader of Linac4, in charge of the commissioning. In 2020, Linac4 will replace the existing Linac2 as the first link in the accelerator chain. It will accelerate beams of H- ions (protons surrounded by two electrons) to 160 MeV, compared to 50 MeV with Linac2. The new machine is particularly sophisticated as it comprises...

  15. Update of the Linac4-PSB Transfer Line

    CERN Document Server

    HEIN, Lutz

    2010-01-01

    The installation of Linac4 represents the first step of the upgrade plans of the CERN accelerator complex for the future in order to raise the available proton flux to attain amongst others the LHC ultimate luminosity. This linac is capable to accelerate H--ions from 45keV to 160MeV, which will be injected into the Proton Synchrotron Booster (PSB). The increase of energy from 50MeV (Linac2) to 160MeV (Linac4) allows to overcome the space charge limitations at the PSB injection, which is the main bottleneck towards higher beam brightness in the downstream accelerator chain. In order to preserve beam quality from the outlet of Linac4 to PSB injection the design of the transfer line becomes crucial. As the location of Linac4 was chosen in view of upgrade scenarios, the construction of a new transfer line is foreseen, see ref.[1] and ref.[2]. Here part of the Linac2-PSB transfer line will be re-used. In the new part of the transfer line the beam is horizontally and vertically adjusted towards the bending magnet B...

  16. Injection schemes for the TOP Linac; Schemi di iniezione per il TOP Linac

    Energy Technology Data Exchange (ETDEWEB)

    Picardi, L.; Ronsivalle, C. [ENEA, Centro Ricerche Frascati, Frascati, RM (Italy). Dipt. Innovazione; Bartolini, R. [Istituto Superiore di Sanita' , Rome (Italy)

    1999-07-01

    In this report two schemes are studied for the injection in the SCDTL section of the TOP Linac of the proton beam produced by a 7 MeV linear accelerator. The project derives by an agreement between ENEA (National Agency for New Technology, Energy and Environment) and ISS. In these new versions of the design the constraint of a synchronization of the radio frequencies of the two accelerators is suppressed. [Italian] In questo rapporto sono studiati due schemi di iniezione nella sezione accelerante SCDTL a 3 GHz del TOP (terapia oncologica con protoni) linac del fascio di protoni generato da un acceleratore lineare di 7 MeV. L'acceleratore e' frutto di una convenzione tra L'ENEA e l'Istituto Superiore di Sanita'. Rispetto a versioni precedenti del progetto, viene eliminato il vincolo della sincronizzazione delle radiofrequenze dei due acceleratori.

  17. Initial operation of the Argonne superconducting heavy-ion linac

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K. W.

    1979-01-01

    Initial operation and recent development of the Argonne superconducting heavy-ion linac are discussed. The linac has been developed in order to demonstrate a cost-effective means of extending the performance of electrostatic tandem accelerators. The results of beam acceleration tests which began in June 1978 are described. At present 7 of a planned array of 22 resonators are operating on-line, and the linac system provides an effective accelerating potential of 7.5 MV. Although some technical problems remain, the level of performance and reliability is sufficient that appreciable beam time is becoming available to users.

  18. Present status of the Tohoku 300 MeV linac

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Akira; Oyamada, Masayuki; Hama, Hiroyuki; Hinode, Fujio; Shinto, Katsuhiro; Takahashi, Shigenobu; Shibasaki, Yohsinobu [Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science

    2000-07-01

    The TOHOKU linac has been operated since 1967, and the integrated operation time reaches 3,000 hours par year in these years. The construction of the Stretcher-Booster (STB) ring was completed in 1996 and the beam commissioning was started from October 1997. Beam supply for the nuclear experiment was started from 1998. Because the linac is getting too old, many components have to be repaired and/or replaced for further continuously stable operation. Present status and improvements for the linac during last year are reported. (author)

  19. Energy Recovery Linacs for Light Source Applications

    Energy Technology Data Exchange (ETDEWEB)

    George Neil

    2011-04-01

    Energy Recovery Linacs are being considered for applications in present and future light sources. ERLs take advantage of the continuous operation of superconducting rf cavities to accelerate high average current beams with low losses. The electrons can be directed through bends, undulators, and wigglers for high brightness x ray production. They are then decelerated to low energy, recovering power so as to minimize the required rf drive and electrical draw. When this approach is coupled with advanced continuous wave injectors, very high power, ultra-short electron pulse trains of very high brightness can be achieved. This paper will review the status of worldwide programs and discuss the technology challenges to provide such beams for photon production.

  20. Beam commissioning for a superconducting proton linac

    Directory of Open Access Journals (Sweden)

    Zhi-Jun Wang

    2016-12-01

    Full Text Available To develop the next generation of safe and cleaner nuclear energy, the accelerator-driven subcritical (ADS system emerges as one of the most attractive technologies. It will be able to transmute the long-lived transuranic radionuclides produced in the reactors of today’s nuclear power plants into shorter-lived ones, and also it will provide positive energy output at the same time. The prototype of the Chinese ADS (C-ADS proton accelerator comprises two injectors and a 1.5 GeV, 10 mA continuous wave (CW superconducting main linac. The injector scheme II at the C-ADS demo facility inside the Institute of Modern Physics is a 10 MeV CW superconducting linac with a designed beam current of 10 mA, which includes an ECR ion source, a low-energy beam transport line, a 162.5 MHz radio frequency quadrupole accelerator, a medium-energy beam transport line, and a superconducting half wave resonator accelerator section. This demo facility has been successfully operating with an 11 mA, 2.7 MeV CW beam and a 3.9 mA, 4.3 MeV CW beam at different times and conditions since June 2014. The beam power has reached 28 kW, which is the highest record for the same type of linear accelerators. In this paper, the parameters of the test injector II and the progress of the beam commissioning are reported.

  1. The invention that shapes Linac4: Tolerance Aligned Cantileaver Mounting (TACM) system to build drift tube linacs

    CERN Multimedia

    CERN Video Productions

    2010-01-01

    Accelerator experts are no new to original optimizations of existing techniques and to the development of novel solutions. Sometimes, they even come up with ideas that have the potential to revolutionize the field. This was indeed the case for the Tolerance Aligned Cantilever Mounting (TACM) system, a completely new way of supporting the drift tubes, one of the core elements of linear accelerators. The new, patent-pending technique will be implemented at Linac4.Interview with Suitbert Ramberger, Project engineer for the Linac4 Drift Tube Linac (DTL).

  2. Interdigitated electrode-induced phase grating with an electrically switchable and tunable period.

    Science.gov (United States)

    Kulishov, M

    1999-12-20

    A new design for an adjustable electro-optic phase grating inside a waveguide is proposed. The electric field and the refractive-index distribution induced inside a waveguide by voltage applied to double-sided periodic interdigitated electrode arrays are calculated rigorously on the basis of an original analytical technique. The modeling was carried out with the Mathcad software. It is shown that the fundamental periodicity of the induced grating inside the waveguide can be switched between l and 2l by application of the appropriate voltage, where l is the spatial periodicity of the interdigitated electrodes. One can also fine tune the peak grating reflectivity by changing the constant component of the induced refractive index with the help of the constant component of the electric field inside the waveguide. The suggested design can be used as a basic idea for a variety of optical communication networking applications, including switching, modulation, deflection, and data processing.

  3. A nanoporous thin-film miniature interdigitated capacitive impedance sensor for measuring humidity

    Directory of Open Access Journals (Sweden)

    T. Islam

    2014-07-01

    Full Text Available This paper presents a development of a low-cost miniature humidity sensor with an interdigitated aluminium electrode connected in parallel on quartz substrate. Interdigitated capacitive device has been fabricated using the photolithography method. The aluminium electrode was covered with sensitive film of a nanoporous thin film of γ-Al2O3 made from novel sol–gel technique. Nanostructured thin film offers very high surface to volume ratio with distribution of micro pores for moisture detection. Pore morphologies of the film have been studied by field emission electron microscope and X-ray diffraction methods. Impedance measurement of the miniature capacitive humidity sensor toward relative humidity was investigated at room temperature by Agilent 4294A impedance analyzer (Agilent, Santa Clara, CA, USA. The device exhibits short response and recovery times and good repeatability.

  4. An Inter-digital Capacitive Electrode Modified as a Pressure Sensor

    Directory of Open Access Journals (Sweden)

    T. J. GINSON

    2008-12-01

    Full Text Available Inter-digital capacitive electrodes working as electric field sensors have been developed for touch panel applications. Evaluation circuits to convert variations in electric fields in such sensors into computer compatible data are commercially available. We report development of an Interdigital capacitive electrode working as a sensitive pressure sensor in the range 0-120 kPa. Essentially it is a touch/proximity sensor converted into a pressure sensor with a suitable elastomer buffer medium acting as the pressure transmitter. The performance of the sensor has been evaluated and reported. Such sensors can be made very economical in comparison to existing pressure sensors. Moreover, they are very convenient to be fabricated into sensor arrays involving a number of sensors for distributed pressure sensing applications such as in biomedical systems.

  5. Interdigitated Electrode-Induced Phase Grating with an Electrically Switchable and Tunable Period

    Science.gov (United States)

    Kulishov, Mykola

    1999-12-01

    A new design for an adjustable electro-optic phase grating inside a waveguide is proposed. The electric field and the refractive-index distribution induced inside a waveguide by voltage applied to double-sided periodic interdigitated electrode arrays are calculated rigorously on the basis of an original analytical technique. The modeling was carried out with the Mathcad software. It is shown that the fundamental periodicity of the induced grating inside the waveguide can be switched between l and 2 l by application of the appropriate voltage, where l is the spatial periodicity of the interdigitated electrodes. One can also fine tune the peak grating reflectivity by changing the constant component of the induced refractive index with the help of the constant component of the electric field inside the waveguide. The suggested design can be used as a basic idea for a variety of optical communication networking applications, including switching, modulation, deflection, and data processing.

  6. A Radiation shielding study for the Fermilab Linac

    Energy Technology Data Exchange (ETDEWEB)

    Rakhno, I.; Johnstone, C.; /Fermilab

    2006-02-01

    Radiation shielding calculations are performed for the Fermilab Linac enclosure and gallery. The predicted dose rates around the access labyrinth at normal operation and a comparison to measured dose rates are presented. An accident scenario is considered as well.

  7. HOM Dampers or not in Superconducting RF Proton Linacs

    CERN Document Server

    Tückmantel, Joachim

    2009-01-01

    Circular machines are plagued by Coupled Bunch Instabilities, driven by impedance peaks, irrespectively of their frequency relation to machine lines; hence all cavity Higher Order Modes are possible drivers. This is the fundamental reason that all superconducting RF cavities in circular machines are equipped with HOM dampers. This raises the question if HOM damping would not be imperative also in high current proton linacs where a mechanism akin to CBI might exist. To clarify this question we have simulated the longitudinal bunched beam dynamics in linacs, allowing bunch-to-bunch variations in time-of-arrival. Simulations were executed for a generic proton linac with properties close to SNS or the planned SPL at CERN. It was found that for monopole HOMs with high Qext large beam scatter or even beam loss cannot be excluded. Therefore omitting HOM dampers on superconducting RF cavities in high current proton linacs, even pulsed ones, is a very risky decision.

  8. HOM Dampers or not in SUPERCONDUCTING RF Proton Linacs

    CERN Document Server

    Tückmantel, Joachim

    2009-01-01

    Circular machines are plagued by Coupled Bunch Instabilities, driven by impedance peaks, irrespectively of their frequency relation to machine lines; hence all cavity Higher Order Modes are possible drivers. This is the fundamental reason that all superconducting RF cavities in circular machines are equipped with HOM dampers. This raises the question if HOM damping would not be imperative also in high current proton linacs where a mechanism akin to CBI might exist. To clarify this question we have simulated the longitudinal bunched beam dynamics in linacs, allowing bunch-to-bunch variations in time-of-arrival. Simulations were executed for a generic proton linac with properties close to SNS or the planned SPL at CERN. It was found that for monopole HOMs with high Qext large beam scatter or even beam loss cannot be excluded. Therefore omitting HOM dampers on superconducting RF cavities in high current proton linacs, even pulsed ones, is a very risky decision.

  9. Proposal for a new proton injector for LINAC2

    CERN Document Server

    Couturier, B

    1997-01-01

    The CERN proton Drift Tube LINAC (LINAC2) has been serving as proton injector to the PS Booster for over 20 years. In 1992 the pre-accelerator (composed of a 750 keV column and a double buncher system) has been replaced by a Radio Frequency Quadrupole (RFQ2) able to be accelerated excess of 200 mA of protons. 160 mA-proton beam are delivered to the booster during normal operation, 180mA during high intensity operation. Although this value is satisfying for the future LHC operation, a larger margin would be welcome ( 180mA for production beam, 200 mA for high intensity operation). In this note we propose a solution to improve the overall performance of the CERN proton LINAC (LINAC2).

  10. Dense high-aspect ratio 3D carbon pillars on interdigitated microelectrode arrays

    DEFF Research Database (Denmark)

    Amato, Letizia; Heiskanen, Arto; Hansen, Rasmus

    2015-01-01

    In this work we present high-aspect ratio carbon pillars (1.4 μm in diameter and ∼11 μm in height) on top of interdigitated electrode arrays to be used for electrochemical applications. For this purpose, different types of 2D and 3D pyrolysed carbon structures were fabricated and characterised...... of pyrolysed carbon films with increased film resistance due to oxidation during storage....

  11. Interdigitated Back-Surface-Contact Solar Cell Modeling Using Silvaco Atlas

    Science.gov (United States)

    2015-06-01

    photovoltaic device, back surface contact, Silvaco Atlas, Interdigitated, silicon 15. NUMBER OF PAGES 89 16. PRICE CODE 17. SECURITY CLASSIFICATION OF...can be viewed in Tonyplot and show many parameters of the device. Early on in the thesis work there were issues with plotting a basic IV curve...Michalopoulos, “A novel approach for the development and optimization of state-of-the-art photovoltaic devices using Silvaco,” M.S. thesis, Dept. of

  12. Detection of bacterial endotoxin in food: New planar interdigital sensors based approach

    KAUST Repository

    Abdul Rahman, Mohd Syaifudin

    2013-02-01

    Food poisoning caused by endotoxins or Lipopolysaccharide (LPS) are associated with Gram-negative bacteria. Two major food-borne pathogens, Escherichia coli and Salmonella are examples of Gram-negative bacteria which cause a large number of outbreaks of food poisoning. New types of planar interdigital sensors have been fabricated with different coating materials to assess their response to endotoxins. A carboxyl-functional polymer, APTES (3-Aminopropyltriethoxysilane) and Thionine were chosen to be coated onto FR4 interdigital sensors. The chosen coating materials have carboxylic or amine functional groups, which were optimized to be stable in water. All coated sensors were immobilized with PmB (Polymyxin B) which has specific binding properties to LPS. The sensors were tested with different concentrations of LPS O111:B4, ranging from 0.1 to 1000 μg/ml. Analyses of sensors\\' performance were based on the impedance spectroscopy method. The impedance spectra were modeled using a constant phase-element (CPE) equivalent circuit, and a principal component analysis (PCA) was used for data classification. Sensor coated with APTES has shown better selectivity for LPS detection. The experiments were repeated by coating APTES and immobilizing PmB to a new improve designed of novel interdigital sensors (thin film silicon based sensors). These sensors were observed to have better sensitivity and selectivity to the target biomolecules of LPS. Further experiments were conducted to study the effect of different coating thickness on sensor sensitivity, selectivity and stability. Different food samples contaminated with endotoxin were also tested to verify that the interdigital sensing approach is able to be used for endotoxin detection. © 2012 Elsevier Ltd. All rights reserved.

  13. Optimization of Thick Negative Photoresist for Fabrication of Interdigitated Capacitor Structures

    Science.gov (United States)

    2015-04-01

    the PR chemical. After exposure, a postexposure bake step using a hot plate or oven heating is used to complete the chemical transformations ...interdigitated capacitor (IDC) structures by lift-off process for use in high-frequency electrical characterization measurements. Target feature resolution was...spin-coat application, a soft-bake step is required to evaporate solvents and harden the PR layer. This can be performed either by hot plate or oven

  14. Spin-polarized transport in a two-dimensional electron gas with interdigital-ferromagnetic contacts

    DEFF Research Database (Denmark)

    Hu, C.-M.; Nitta, Junsaku; Jensen, Ane

    2001-01-01

    Ferromagnetic contacts on a high-mobility, two-dimensional electron gas (2DEG) in a narrow gap semiconductor with strong spin-orbit interaction are used to investigate spin-polarized electron transport. We demonstrate the use of magnetized contacts to preferentially inject and detect specific spin...... orientations. Spin dephasing and spin precession effects are studied by temperature and 2DEG channel length dependent measurements. Interdigital-ferromagnetic contacts suppress unwanted effects due to ferromagnetic microstrip inhomogeneities by averaging....

  15. Evolution of the 400 MeV linac design

    Energy Technology Data Exchange (ETDEWEB)

    MacLachlan, J.A.

    1987-11-09

    The basic premises of the conceptual design for the linac upgrade are pursued to establish lengths, gradients, power dissipation, etc., for the 400 MeV linac and matching section. The discussion is limited to accelerating and focusing components. Wherever values depend on the choice of the accelerating structure, the disk-and-washer structure is emphasized; the results are generally relevant to the side coupled cavity choice also.

  16. High power operational experience with the LANSCE Linac

    Energy Technology Data Exchange (ETDEWEB)

    Rybarcyk, Lawrence J [Los Alamos National Laboratory

    2008-01-01

    The heart of the Los Alamos Neutron Science Center (LANSCE) is a pulsed linear accelerator that is used to simultaneously provide H+ and H- beams to several user facilities. This accelerator contains two Cockcroft-Walton style injectors, a 100-MeV drift tube linac and an 800-MeV coupled cavity linac. This presentation will touch on various aspects of the high power operation including performance, tune-up strategy, beam losses and machine protection.

  17. Effect of cooling water on stability of NLC linac components

    Energy Technology Data Exchange (ETDEWEB)

    F. Le Pimpec et al.

    2003-02-11

    Vertical vibration of linac components (accelerating structures, girders and quadrupoles) in the NLC has been studied experimentally and analytically. Effects such as structural resonances and vibration caused by cooling water both in accelerating structures and quadrupoles have been considered. Experimental data has been compared with analytical predictions and simulations using ANSYS. A design, incorporating the proper decoupling of structure vibrations from the linac quadrupoles, is being pursued.

  18. Effect of Cooling Water on Stability of NLC Linac Components

    Energy Technology Data Exchange (ETDEWEB)

    Le Pimpec, Frederic

    2002-11-01

    Vertical vibration of linac components (accelerating structures, girders and quadrupoles) in the NLC has been studied experimentally and analytically. Effects such as structural resonances and vibration caused by cooling water both in accelerating structures and quadrupoles have been considered. Experimental data has been compared with analytical predictions and simulations using ANSYS. A design, incorporating the proper decoupling of structure vibrations from the linac quadrupoles, is being pursued.

  19. Linac 1 in the process of being pulled back

    CERN Multimedia

    Photographic Service; CERN PhotoLab

    1985-01-01

    As injector to the PS Booster, Linac 1 was replaced by Linac 2 in 1980. It continued to be used for the acceleration of oxygen and sulfur ions and, from 1981 to 1996, of protons and negative hydrogen ions for LEAR. In 1984, its Cockcroft-Walton preinjector was replaced by a much smaller RFQ, which allowed it to be moved to a more convenient location.

  20. Ultrashort X-ray pulse generation using subpicosecond electron linac

    CERN Document Server

    Harano, H; Yoshii, K; Ueda, T; Okita, S; Uesaka, M

    2000-01-01

    As a promising tool for ultrafast material analyses, we propose to utilize the X-ray pulse which may be generated in a quite simple manner using subpicosecond electron linacs. The properties of the X-ray were numerically studied with the EGS4 code. Verification of the X-ray generation was also conducted at the Nuclear Engineering Research Laboratory (NERL) linac and clear diffraction patterns of characteristic X-ray were obtained for typical single crystals.

  1. Vibrational Stability of NLC Linac and Final Focus Components

    Energy Technology Data Exchange (ETDEWEB)

    Le Pimpec, Frederic

    2002-09-25

    Vertical vibration of linac components (accelerating structures, girders and quadrupoles) in the NLC has been studied experimentally and analytically. Effects such as structural resonances and vibration caused by cooling water both in accelerating structure and quadrupoles have been considered. Experimental data has been compared with analytical predictions and simulations using ANSYS. Design to properly decouple the structure vibrations from the linac quadrupoles is being pursued.

  2. Thermal stress in flexible interdigital transducers with anisotropic electroactive cellulose substrates

    Science.gov (United States)

    Yoon, Sean J.; Kim, Jung Woong; Kim, Hyun Chan; Kang, Jinmo; Kim, Jaehwan

    2017-12-01

    Thermal stress in flexible interdigital transducers a reliability concern in the development of flexible devices, which may lead to interface delamination, stress voiding and plastic deformation. In this paper, a mathematical model is presented to investigate the effect of material selections on the thermal stress in interdigital transducers. We modified the linear relationships in the composite materials theory with the effect of high curvature, anisotropic substrate and small substrate thickness. We evaluated the thermal stresses of interdigital transducers, fabricated with various electrodes, insulators and substrate materials for the comparison. The results show that, among various insulators, organic polymer developed the highest stress level while oxide showed the lowest stress level. Aluminium shows a higher stress level and curvature as an electrode than gold. As substrate materials, polyimide and electroactive cellulose show similar stress levels except the opposite sign convention to each other. Polyimide shows positive curvatures while electroactive cellulose shows negative curvatures, which is attributed to the stress and thermal expansion state of the metal/insulator composite. The results show that the insulator is found to be responsible for the confinement across the metal lines while the substrate is responsible for the confinement along the metal lines.

  3. Pathogenesis of canine interdigital palmar and plantar comedones and follicular cysts, and their response to laser surgery.

    Science.gov (United States)

    Duclos, David D; Hargis, Ann M; Hanley, Patrick W

    2008-06-01

    This study documents the presence of comedones and follicular cysts of palmar and plantar interdigital skin as an underlying cause of recurrent dermatitis, and describes the use of a carbon dioxide laser to surgically remove lesions. The 28 dogs included in the study had: (i) recurrent lameness, pain, and nodules, or draining sinuses in the dorsal interdigital skin, (ii) failed to respond to antibiotic therapy, and (iii) were negative for Demodex mites and dermatophytes. All 28 had laser surgery; nine dogs had two surgical procedures and two dogs had three surgical procedures for lesion recurrence. Fifteen dogs had skin samples collected for histopathology. Clinical features in ventral interdigital skin included alopecia, callus-like thickening, and comedones. Histological features included hyperkeratosis, acanthosis, comedones and follicular cysts, furunculosis, draining sinuses, and scarring. Surface trauma to the ventral interdigital skin appeared to contribute to lesion development. Laser surgery allowed removal of multiple layers of cysts and adjacent hair follicles and the tracking and removal of sinuses. One dog was euthanized for orthopaedic lameness 1 month after laser surgery, but post-surgical follow-up (1.0-8.0 years - mean 3 years) from the remaining 27 dogs revealed that laser therapy of affected skin and adjacent hair follicles resulted in resolution of interdigital lesions in 25. Two dogs continued to develop interdigital cysts.

  4. Influence of the interdigitated gel phase in mixtures of ether-linked and monofluorinated ester-linked phospholipids.

    Science.gov (United States)

    Smith, Eric A; Dea, Phoebe K

    2012-12-01

    To evaluate the influence of the hydrocarbon chain linkage on the thermodynamic phase behavior of spontaneously interdigitating lipids, mixtures of ether-linked 1,2-di-O-hexadecyl-phosphocholine (DHPC) and ester-linked 1-palmitoyl-2-[16-fluoropalmitoyl]sn-glycero-3-phosphocholine (F-DPPC) were studied. A combination of differential scanning calorimetry (DSC), fluorescence spectroscopy, and transmittance spectrophotometry was used. Small amounts of F-DPPC increase the pretransition temperature (T(p)) between the interdigitated gel phase (L(β)I) and the ripple gel phase (P(β)'). There are some signs of immiscibility where the non-interdigitated lipid is present in the phase diagram. However, at around 20mol.% F-DPPC, the pretransition merges with the main transition and is no longer detectable as a separate entity. Additionally, the T(m) hysteresis increases steadily with higher mole fractions of F-DPPC. These results support that incorporating F-DPPC progressively stabilizes the L(β)I phase of DHPC until the membrane is fully interdigitated below the main transition temperature (T(m)). The mixtures of F-DPPC and DHPC are miscible once the membrane is entirely interdigitated in the gel phase. Therefore, the ability of both lipids to interdigitate is an important factor controlling gel phase miscibility. Our results also demonstrate that the gel phase behavior of DHPC is highly sensitive to changes in its environment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Progress in the Construction of Linac4 at CERN

    CERN Document Server

    Vretenar, M; Baudrenghien, P; Bertone, C; Body, Y; Broere, J; Brunner, O; Bellodi, G; Buzio, M; Carli, C; Roncarolo, F; Ramberger, S; Raich, U; Puccio, B; Paoluzzi, M; Nisbet, D; Mikulec, B; Mathot, S; Maglioni, C; Lopez-Hernandez, LA; Lombardi, A; Lallement, J B; Lettry, J; Kozsar, I; Hansen, J; Hanke, K; Hammouti, L; Gerigk, F; Garoby, R; Funken, A; Fuchs, J F; Dos Santos, N; Dallocchio, A; Coupard, J; Corso, JP; Scrivens, R; Schwerg, N; Vollaire, J; Zickler, T; Weisz, S; Wegner, R; Vandoni, G; Rossi, C

    2013-01-01

    As first step of the LHC luminosity upgrade program CERN is building a new 160 MeV H¯ linear accelerator, Linac4, to replace the ageing 50 MeV Linac2 as injector to the PS Booster (PSB). Linac4 is an 86-m long normalconducting linac made of a 3 MeV injector followed by 22 accelerating cavities of three different types. The general service infrastructure has been installed in the new tunnel and surface building and its commissioning is progressing; high power RF equipment is being installed in the hall and installations in the tunnel will start soon. Construction of the accelerator parts is in full swing involving industry, the CERN workshops and a network of international collaborations. The injector section including a newly designed and built H¯ source, a 3-m long RFQ and a chopping line is being commissioned in a dedicated test stand. Beam commissioning of the linac will take place in steps of increasing energy between 2013 and 2015. From end of 2014 Linac4 could deliver 50 MeV protons i...

  6. Beam lines from Linac 1 to PS and Booster

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    View against the direction of the proton beams. The 50 MeV Linac 1 is behind the concrete wall. Its beam emerges from the hole near the centre of the picture. A switching magnet directs the beam either to the PS (to the right in the sense of the beam; original injection line), or lets it go straight on to the Booster (originally 800 MeV, now 1.4 GeV). The huge drum in the line to the Booster is a "debuncher", driven by the 200 MHz RF of the linac. It reduces the beam's momentum spread. This was the last year of Linac 1 as provider of protons to the Booster. Linac 2, nearly completed at the time of this picture, took up trial delivery at the end of 1978, and routine delivery in 1979. The beam line from Linac 2, barely visible here, can be clearly seen on 7802260. Linac 1 had a second life as an ion accelerator.

  7. Physics design of APT linac with normal conducting rf cavities

    Energy Technology Data Exchange (ETDEWEB)

    Nath, S.; Billen, J.H.; Stovall, J.E.; Takeda, Harunori; Young, L.M.

    1996-09-01

    The accelerator based production of tritium calls for a high-power, cw proton linac. Previous designs for such a linac use a radiofrequency quadrupole (RFQ), followed by a drift-tube linac (DTL) to an intermediate energy and a coupled-cavity linc (CCL) to the final energy. The Los Alamos design uses a high-energy (6.7 MeV) RFQ followed by the newly developed coupled-cavity drift-tube linac (CCDTL) and a CCL. This design accommodates external electromagnetic quadrupole lenses which provide a strong uniform focusing lattice from the end of the RFQ to the end of the CCL. The cell lengths in linacs of traditional design are typically graded as a function of particle velocity. By making groups of cells symmetric in both the CCDTL and CCL, the cavity design as well as mechanical design and fabrication is simplified without compromising the performance. At higher energies, there are some advantages of using superconducting rf cavities. Currently, such schemes are under vigorous study. This paper describes the linac design based on normal conducting cavities and presents simulation results.

  8. Status and plans for Linac4 installation and commissioning

    CERN Document Server

    Vretenar, M; Arnaudon, L; Baudrenghien, P; Bellodi, G; Broere, J; Brunner, O; Comblin, J F; Coupard, J; Dimov, V A; Fuchs, J F; Funken, A; Gerigk, F; Granemann Souza, E; Hanke, K; Hansen, J; Yarmohammadi Satri, M; Kozsar, I; Lallement, J B; Lenardon, F; Lettry, J; Lombardi, A M; Maglioni, C; Midtun, O; Mikulec, B; Nisbet, D; Paoluzzi, M; Raich, U; Ramberger, S; Roncarolo, F; Rossi, C; Sanchez Alvarez, J L; Scrivens, R; Tan, J; Valerio-Lizarraga, C A; Vollaire, J; Wegner, R; Weisz, S; Zocca, F

    2014-01-01

    Linac4 is a normal conducting 160 MeV Hˉ linear accelerator presently being installed and progressively commissioned at CERN. It will replace the ageing 50 MeV Linac2 as injector of the PS Booster (PSB), increasing at the same time its brightness by a factor of two thanks to the higher injection energy. This will be the first step of a program to increase the beam brightness in the LHC injectors for the needs of the High-Luminosity LHC project. After a series of beam measurements on a dedicated test stand the 3 MeV Linac4 front-end, including ion source, RFQ and a beam chopping line, has been recommissioned at its final position in the Linac4 tunnel. Commissioning of the following section, the Drift Tube Linac, is starting. Beam commissioning will take place in steps of increasing energy, to reach the final 160 MeV in 2015. An extended beam measurement phase including testing of stripping equipment for the PSB and a year-long test run to assess and improve Linac4 reliability will take place in 2016, prior to...

  9. HELIOS, the Linac Injector of SOLEIL Installation and First Results

    CERN Document Server

    Pottin, Bruno; Jousse, Dominique; Pastre, Jean-Luc; Pollina, Jean-Pierre; Setty, Andrew; Tordeux, Marie-Agnès

    2005-01-01

    HELIOS is the Hundred MeV Electron Linac Injector Of SOLEIL the new French SR facility. The Linac is constructed by THALES as a “turn key” equipment on the basis of SOLEIL's APD design. The Linac injector is composed of a triode gun (90 kV, 500 mA), a prebuncher (10 kV, 200 W), a buncher (SW, 15 MeV, 5 MW) focalised by a solenoid and two accelerating sections (TW, 2pi/3, 45 MeV, 12 MW) feeded by 2 klystrons (35 MW). The major Linac components have been previously tested at THALES factory and the installation on the site has begun from October 2004. After a brief description of the building construction, the tests of the Linac components and operating modes will be detailed. The commissioning with beam is planned on March; the results on beam qualities will be presented: energy spread, emittance, and beam dynamics along the Linac.

  10. Beam dynamics studies of the HIE-LINAC at CERN

    CERN Document Server

    Fraser, MA

    2008-01-01

    We present a beam dynamics study of the superconducting (SC) HIE-LINAC proposed to replace the existing normal conducting REX-ISOLDE accelerating infrastructure at CERN. The Linear Accelerator Numerical Analysis (LANA) code was used to run first-order simulations of the HIE-LINAC in order to study the beam quality during acceleration. A resonance in the transverse emittance growth at ejection from the HIE-LINAC was discovered and understood as a parametric coupling between the longitudinal and transverse dynamics. The dangerous effect of this resonance can be avoided for all mass-to-charge states in the range 2.5 ≤ A/q ≤ 4.5, if the linac is operated with a transverse phase advance higher than 70 degrees. The transverse emittance growth is minimised along the HIE-LINAC if operated above a transverse phase advance of 90 degrees per focusing period. Without a dedicated matching region between the two sections of the HIE-LINAC a solution for matching the beam was found by using the solenoids in the low-energ...

  11. A novel electron gun for inline MRI-linac configurations.

    Science.gov (United States)

    Constantin, Dragoş E; Holloway, Lois; Keall, Paul J; Fahrig, Rebecca

    2014-02-01

    This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Simple electron gun geometry modifications of a Varian 600 C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600 C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ± 15 cm along the axis of the 0.5 T magnet without capture

  12. Linac design for intense hadron beams

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chuan

    2009-12-14

    Based on the RFQ and H-type DTL structures, this dissertation is dedicated to study the beam dynamics in the presence of significantly strong space-charge effects while accelerating intense hadron beams in the low- and medium-{beta} region. Besides the 5 mA/30 mA, 17 MeV proton injector (RFQ+DTL) and the 125 mA, 40 MeV deuteron DTL of the EUROTRANS and IFMIF facilities, a 200 mA, 700 keV proton RFQ has been also intensively studied for a small-scale but ultra-intense neutron source FRANZ planned at Frankfurt University. The most remarkable properties of the FRANZ RFQ and the IFMIF DTL are the design beam intensities, 200 mA and 125 mA. A new design approach, which can provide a balanced and accelerated beam bunching at low energy, has been developed for intense beams. To design the IFMIF DTL and the injector DTL part of the EUROTRANS driver linac, which have been foreseen as the first real applications of the novel superconducting CH-DTL structure, intensive attempts have been made to fulfill the design goals under the new conditions. For the IFMIF DTL, the preliminary IAP design has been considerably improved with respect to the linac layout as well as the beam dynamics. By reserving sufficient drift spaces for the cryosystem, diagnostic devices, tuner and steerer, introducing SC solenoid lenses and adjusting the accelerating gradients and accordingly other configurations of the cavities, a more realistic, reliable and efficient linac system has been designed. On the other hand, the specifications and positions of the transverse focusing elements as well as the phase- and energy-differences between the bunch-center particle and the synchronous particle at the beginning of the {phi}{sub s}=0 sections have been totally redesigned. For the EUROTRANS injector DTL, in addition to the above-mentioned procedures, extra optimization concepts to coordinate the beam dynamics between two intensities have been applied. In the beam transport simulations for both DTL designs

  13. Delta undulator for Cornell energy recovery linac

    Directory of Open Access Journals (Sweden)

    Alexander B. Temnykh

    2008-12-01

    Full Text Available In anticipation of a new era of synchrotron radiation sources based on energy recovery linac techniques, we designed, built, and tested a short undulator magnet prototype whose features make optimum use of the unique conditions expected in these facilities. The prototype has pure permanent magnet (PPM structure with 24 mm period, 5 mm diameter round gap, and is 30 cm long. In comparison with conventional undulator magnets it has the following: (i full x-ray polarization control.—It may generate varying linear polarized as well as left and right circular polarized x rays with photon flux much higher than existing Apple-II–type devices. (ii 40% stronger magnetic field in linear and approximately 2 times stronger in circular polarization modes. This advantage translates into higher x-ray flux. (iii Compactness.—The prototype can be enclosed in a ∼20  cm diameter cylindrical vacuum vessel. These advantages were achieved through a number of unconventional approaches. Among them is control of the magnetic field strength via longitudinal motion of the magnet arrays. The moving mechanism is also used for x-ray polarization control. The compactness is achieved using a recently developed permanent magnet soldering technique for fastening PM blocks. We call this device a “Delta” undulator after the shape of its PM blocks. The presented article describes the design study, various aspects of the construction, and presents some test results.

  14. Status of the SNS Linac An Overview

    CERN Document Server

    Holtkamp, N

    2004-01-01

    The Spallation Neutron Source SNS is a second generation pulsed neutron source and under construction at Oak Ridge National Laboratory. The SNS is funded by the U.S. Department of Energy?s Office of Basic energy Sciences and is dedicated to the study of the structure and dynamics of materials by neutron scattering. A collaboration composed of six national laboratories (ANL, BNL, TJNAF, LANL, LBNL, ORNL) is responsible for the design and construction of the various subsystems. With the official start in October 1998, the operation of the facility will begin in 2006 and deliver a 1.0 GeV, 1.4 MW proton beam with a pulse length of approximately 700 nanoseconds on a liquid mercury target. The multi-lab collaboration allowed access to a large variety of expertise in order to enhance the delivered beam power by almost an order of magnitude compared to existing neutron facilities. The SNS linac consists of a combination of room temperature and superconducting structures and will be the first pulsed high power sc lin...

  15. Linac4 chopper line commissioning strategy

    CERN Document Server

    Bellodi, G; Lombardi, A M; Posocco, P A; Sargsyan, E

    2010-01-01

    The report outlines the strategy for beam-based commissioning of the Linac4 3 MeV chopper line as currently scheduled to start in the second half of 2011 in the Test Stand Area. A dedicated temporary diagnostics test bench will complement the measurement devices foreseen for permanent installation in the chopper line. A commissioning procedure is set out as a series of consecutive phases, each one supposed to meet a well- defined milestone in the path to fully characterise the beam-line. Specific set-ups for each stage are defined in terms of beam characteristics, machine settings and diagnostics used. Operational guidelines are given and expected results at the relative points of measurements are shown for simulated scenarios (on the basis of multi-particle tracking studies carried out with the codes PATH and TRACEWin). These are then interpreted in the light of the resolution limits of the available diagnostics instruments to assess the precision reach on individual measurements and the feasibility of techn...

  16. Industrial RF Linac Experiences and Laboratory Interactions

    CERN Document Server

    Peiniger, M

    2004-01-01

    Since more than two decades ACCEL Instruments GmbH at Bergisch Gladbach (formerly Siemens/Interatom) is supplying the worldwide accelerator labs with key components like rf cavities and power couplers, s.c. magnets, insertion devices, vacuum chambers and x-ray beamline equipment. Starting with the design and production of turn key SRF accelerating modules in the late 80th, meanwhile ACCEL is engineering, manufacturing, on site commissioning and servicing complete accelerators with guaranteed beam performance. Today, with a staff of more than 100 physicists and engineers and about the same number of manufacturing specialists in our dedicated production facilities, ACCEL's know how and sales volume in this field has accumulated to more than 2000 man years and several hundred Mio €, respectively. Basis of our steady development is a cooperative partnership with the world leading research labs in the respective fields. As an example, for the supply of a turn key 100 MeV injector linac for the Swiss Ligh...

  17. Emittance and Phase Space Tomography for the Fermilab Linac

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, F.G.G.; Johnstone, C.; Kobilarcik, T.; Koizumi, G.M.; Moore, C.D.; /Fermilab; Newhart, D.L.; /Fermilab

    2012-05-01

    The Fermilab Linac delivers a variable intensity, 400-MeV beam to the MuCool Test Area experimental hall via a beam line specifically designed to facilitate measurements of the Linac beam emittance and properties. A 10 m, dispersion-free and magnet-free straight utilizes an upstream quadrupole focusing triplet in combination with the necessary in-straight beam diagnostics to fully characterize the transverse beam properties. Since the Linac does not produce a strictly elliptical phase space, tomography must be performed on the profile data to retrieve the actual particle distribution in phase space. This is achieved by rotating the phase space distribution using different waist focusing conditions of the upstream triplet and performing a deconvolution of the profile data. Preliminary measurements using this diagnostic section are reported here. These data represent a first-pass measurement of the Linac emittance based on various techniques. It is clear that the most accurate representation of the emittance is given by the 3-profile approach. Future work will entail minimizing the beam spot size on MW5 to test and possibly improve the accuracy of the 2-profile approach. The 95% emittance is {approx} 18{pi} in the vertical and {approx} 13{pi} in the horizontal, which is especially larger than anticipated - 8-10{pi} was expected. One possible explanation is that the entire Linac pulse is extracted into the MTA beamline and during the first few microseconds, the feed forward and RF regulation are not stable. This may result in a larger net emittance observed versus beam injected into Booster, where the leading part of the Linac beam pulse is chopped. Future studies will clearly entail a measurement of the emittance vs. pulse length. One additional concern is that the Linac phase space is most likely aperture-defined and non-elliptical in nature. A non-elliptical phase-space determination would require a more elaborate analysis and provide another explanation of the

  18. Deliverable D3 - Low- and Medium-beta linac

    CERN Document Server

    A. Facco, A. Balabin, R. Paparella, D. Zenere, INFN-Laboratori Nazionali di Legnaro, Padova, Italy; D. Berkovits, J. Rodnizki, SOREQ, Yavne, Israel; J. L. Biarrotte, S. Bousson, A. Ponton, G. Olry, IPN Orsay, France; R. Duperrier, D. Uriot, CEA/Saclay, France; V. Zvyagintsev, TRIUMF, Vancouver, Canada.

    The present document describes the Low- and Medium-beta section of the EURISOL DS Driver Accelerator. This section consists of a superconducting linac, based on Half-Wave (HWR) and SPOKE type resonators, preceded by a short, normal-conducting MEBT (Medium Energy Beam Transport) section that performs input beam matching. The scope of this linac is to bring the beams of H-, D+ and 3He++ produced by the Ion Injector (Deliverable D-5) to the energy and beam parameters required for injection in the superconducting High-beta linac (Deliverable D4-High beta linac). The present beam dynamics design reaches the goal of accelerating the required high current beams to the design energy (about 100 MeV/A, depending on the ion species), with minimum emittance growth and with low losses, using realistic and cost-effective, although innovative, technological solutions. The Low- and Medium-beta linac layout is described, together with the fundamental parameters and characteristics of its components and the system performance.

  19. Deliverable D3 - Low- and Medium-beta linac

    CERN Document Server

    A. Facco, A. Balabin, R. Paparella, D. Zenere, INFN-Laboratori Nazionali di Legnaro, Padova, Italy; D. Berkovits, J. Rodnizki, SOREQ, Yavne, Israel; J. L. Biarrotte, S. Bousson, A. Ponton, G. Olry, IPN Orsay, France; R. Duperrier, D. Uriot, CEA/Saclay, France; V. Zvyagintsev, TRIUMF, Vancouver, Canada.

    The present document describes the Low- and Medium-beta section of the EURISOL DS Driver Accelerator. This section consists of a superconducting linac, based on Half-Wave (HWR) and SPOKE type resonators, preceded by a short, normal-conducting MEBT (Medium Energy Beam Transport) section that performs input beam matching. The scope of this linac is to bring the beams of H-, D+ and 3He++ produced by the Ion Injector (Deliverable D-5) to the energy and beam parameters required for injection in the superconducting High-beta linac (Deliverable D4-High beta linac). The present beam dynamics design reaches the goal of accelerating the required high current beams to the design energy (about 100 MeV/A, depending on the ion species), with minimum emittance growth and with low losses, using realistic and cost-effective, although innovative, technological solutions. The Low- and Medium-beta linac layout is described, together with the fundamental parameters and characteristics of its components and the system performanc...

  20. Emittance reconstruction technique for the Linac4 high energy commissioning

    CERN Document Server

    Lallement, JB; Posocco, PA

    2012-01-01

    Linac4 is a new 160 MeV linear accelerator for negative Hydrogen ions (H-) presently under construction which will replace the 50 MeV proton Linac2 as injector for the CERN proton accelerator complex. Linac4 is 80 meters long and comprises a Low Energy Beam Transport line, a 3 MeV RFQ, a MEBT, a 50 MeV DTL, a 100 MeV CCDTL and a PIMS up to 160 MeV. The commissioning of the Linac is scheduled to start in 2013. It will be divided into several steps corresponding to the commissioning of the different accelerating structures. A temporary measurement bench will be dedicated to the high energy commissioning from 30 to 100 MeV (DTL tanks 2 and 3, and CCDTL). The commissioning of the PIMS will be done using the permanent equipment installed in between the end of the Linac and the main dump. This note describes the technique we will use for reconstructing the transverse emittances and the expected results.

  1. Fabrication and characterization of spiral interdigitated electrodes based biosensor for salivary glucose detection

    Science.gov (United States)

    Adelyn, P. Y. P.; Hashim, U.; Arshad, M. K. Md; Voon, C. H.; Liu, Wei-Wen; Kahar, S. M.; Huda, A. R. N.; Lee, H. Cheun

    2017-03-01

    This work introduces the non-invasive glucose monitoring technique by using the Complementary Metal Oxide Semiconductor (CMOS) technologically fabricated spiral Interdigitated Electrodes (IDE) based biosensor. Scanning Electron Microscopy (SEM) image explores the morphology of spiral IDE while Energy Dispersive X-Ray (EDX) determines the elements induced in spiral IDE. Oral saliva of two patients are collected and tested on the spiral IDE sensor with electrical characterization as glucose detection results. However, both patients exhibit their glucose level characteristics inconsistently. Therefore, this work could be extended and enhanced by adding Glutaraldehyde in between 3-Aminoproply)triethoxysilane (APTES) modified and glucose oxidase (GOD) enzyme immobilized layer with FTIR validation for bonding attachment.

  2. One-Dimensional Contact Mode Interdigitated Center of Pressure Sensor (CMIPS)

    Science.gov (United States)

    Xu, Tian-Bing; Kang, Jinho; Park, Cheol; Harrison, Joycelyn S.; Guerreiro, Nelson M.; Hubbard, James E.

    2009-01-01

    A one dimensional contact mode interdigitated center of pressure sensor (CMIPS) has been developed. The experimental study demonstrated that the CMIPS has the capability to measure the overall pressure as well as the center of pressure in one dimension, simultaneously. A theoretical model for the CMIPS is established here based on the equivalent circuit of the configuration of the CMIPS as well as the material properties of the sensor. The experimental results match well with theoretical modeling predictions. A system mapped with two or more pieces of the CMIPS can be used to obtain information from the pressure distribution in multi-dimensions.

  3. A Compact Multiband BPF Using Step-impedance Resonators with Interdigital Capacitors

    OpenAIRE

    Meesomklin, S.; P. Chomtong; P. Akkaraekthalin

    2016-01-01

    A compact multiband band-pass filter design for applications of GSM, Wi-MAX and WLAN systems is presented. The design is based on the resonant characteristics of step-impedance and interdigital capacitor resonators with overlap cross coupling structure. The fabricated filter has been operated at the fundamental, first and second harmonic resonant frequencies of 1.8 GHz, 3.7 GHz, and 5.2 GHz, respectively. The experimental results of the fabricated filter agree very well with the simulation ex...

  4. Characterizations and performance evaluations of thin film interdigital sensors for Gram-negative bacteria detection

    KAUST Repository

    Mohd. Syaifudin, A. R.

    2011-11-01

    Thin film interdigital sensors have been designed and fabricated. The sensors were fabricated using different substrates and using different fabrication technology. The initial design was fabricated on glass slide and fabricated using IDT (Intergrated Device Technology). The new sensors were fabricated on silicon/silicon dioxide wafer. All sensors were coated with APTES, a cross-linker bind to certain bio-molecules and then were immobilized with Polymyxin B, a specific bio-molecules that bind to endotoxin (Lipopolysaccharide, LPS). Sensors were tested for different concentrations of LPS. The impedance characteristics were presented using Impedance Spectroscopy method. A principle component analysis (PCA) was used for better data classification method. © 2011 IEEE.

  5. Boronate-Modified Interdigitated Electrode Array for Selective Impedance-Based Sensing of Glycated Hemoglobin

    DEFF Research Database (Denmark)

    Boonyasit, Yuwadee; Laiwattanapaisal, Wanida; Chailapakul, Orawon

    2016-01-01

    -aminophenylboronic acid (APBA), which selectively binds HbA1c via cis-diol interactions. Impedance sensing was demonstrated to be highly responsive to the clinically relevant HbA1c levels (0.1%-8.36%) with a detection limit of 0.024% (3σ). The specificity of the assay was evaluated with non-glycated hemoglobin (Hb......An impedance-based label-free affinity sensor was developed for the recognition of glycated hemoglobin (HbA1c). Interdigitated gold microelectrode arrays (IDA) were first modified with a self-assembled monolayer of cysteamine followed by cross-linking with glutaraldehyde and subsequent binding of 3...

  6. Analytical solutions of the dielectrophoretic and travelling wave forces generated by interdigitated electrode arrays

    Energy Technology Data Exchange (ETDEWEB)

    Sun Tao; Morgan, Hywel; Green, Nicolas G [Nanoscale Systems Integration Group, School of Electronics and Computer Science, University of Southampton, SO17 1BJ (United Kingdom)], E-mail: ts04r@ecs.soton.ac.uk, E-mail: ng2@ecs.soton.ac.uk

    2008-12-01

    In AC electrokinetics, the application of an AC electric field to a suspension of particles results in the manipulation and separation of the particles also the movement of the fluid. One application is dielectrophoresis (DEP). The second effect is travelling wave dielectrophoresis (twDEP). This paper presents the analytical solutions of the dielectrophoretic and travelling wave forces for the interdigitated electrode arrays energised with either a two- or four-phase signal, respectively. The torque that rotates the particle in the four-phase travelling wave arrays is also analytically solved.

  7. Low stoichiometry operation of a polymer electrolyte membrane fuel cell employing the interdigitated flow field design

    DEFF Research Database (Denmark)

    Berning, Torsten; Odgaard, Madeleine; Kær, Søren Knudsen

    2011-01-01

    Fuel cell operation on dry reactant gases under low stoichiometry conditions employing the interdigitated flow field is investigated using a multi-fluid model. It is assumed that the MEA contains a water uptake layer which facilitates water absorption to the membrane and hence prevents the anode...... stoichiometry may even be as low as 1.05. The effect of operation pressure and temperature on the membrane water content is studied. Finally, experiments are suggested to determine the kinetic absorption coefficient and the specific surface area of the electrolyte inside the catalyst layers....

  8. Real-Time Wireless Moisture Sensing in Concrete Using Interdigitated Stick-on Sensors

    Directory of Open Access Journals (Sweden)

    Rashed H. Bhuiyan

    2015-12-01

    Full Text Available The analyses, design, and performance of an interdigitated moisture sensor are presented. The analytical results clearly delineate the scope of the design in terms of the expected electric field penetration depth and interelectrode capacitance when the sensor is placed on top of a Material Under Test (MUT for a simple two electrode sensor. A multielectrode circular sensor was fabricated, instrumented, and used to measure concrete moisture content. Real-time moisture measurement results in both fresh concrete (when curing and dry concrete (when moisture intrusion is occurring are presented in a wireless system level measurement scenario where the measured results are relayed to a distant receiver using a wireless transmitter.

  9. Optimization of interdigitated electrode (IDE) arrays for impedance based evaluation of Hs 578T cancer cells

    Science.gov (United States)

    Alexander, Frank, Jr.; Price, Dorielle T.; Bhansali, Shekhar

    2010-04-01

    This paper examines the effect of electrode width and spacing of interdigitated electrodes (IDEs) for impedance-based cancer detection and characterization. IDEs are desired for bioimpedance measurements because their fabrication process is simple and inexpensive, and the geometry presents a potential for improved sensitivity over other microelectrode designs. Optimizing the geometry will eliminate this problem and increase the sensitivity of these devices for bioimpedance measurement applications. This paper evaluates the effect of IDE geometry on the sensitivity of breast cancer cell impedance measurements. Equivalent circuit data analysis was conducted to quantify and characterize the cells.

  10. High-Performance Beam Simulator for the LANSCE Linac

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Xiaoying [Los Alamos National Laboratory; Rybarcyk, Lawrence J. [Los Alamos National Laboratory; Baily, Scott A. [Los Alamos National Laboratory

    2012-05-14

    A high performance multiparticle tracking simulator is currently under development at Los Alamos. The heart of the simulator is based upon the beam dynamics simulation algorithms of the PARMILA code, but implemented in C++ on Graphics Processing Unit (GPU) hardware using NVIDIA's CUDA platform. Linac operating set points are provided to the simulator via the EPICS control system so that changes of the real time linac parameters are tracked and the simulation results updated automatically. This simulator will provide valuable insight into the beam dynamics along a linac in pseudo real-time, especially where direct measurements of the beam properties do not exist. Details regarding the approach, benefits and performance are presented.

  11. Reliability and Availability Studies in the RIA Linac Driver

    CERN Document Server

    Schnirman-Lessner, Eliane

    2005-01-01

    The RIA facility will include various complex systems and must provide radioactive beams to many users simultaneously. The availability of radioactive beams for most experiments at the fully-commissioned facility should be as high as possible within design cost limitations. To make a realistic estimate of the achievable reliability a detailed analysis is required. The RIA driver linac is a complex machine containing a large number of SC resonators and capable of accelerating multiple-charge-state beams. At the pre-CDR stage of the design it is essential to identify critical facility subsystem failures that can prevent the driver linac from operating. The reliability and availability of the driver linac are studied using expert information and data from operating machines such as ATLAS, APS, JLab, and LANL. Availability studies are performed with a Monte-Carlo simulation code previously applied to availability assessments of the NLC facility [http://www.slac.stanford.edu/xorg/accelops/Full/LCoptsfull] and the ...

  12. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; O’Neil, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Steyaert, D; Thaus, N; Hatayama, A; Nishida, K; Shibata, T; Yamamot, T; Otha, M

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the LEBT, RFQ and chopper of Linac4.

  13. 400-MeV upgrade for the Fermilab linac

    Energy Technology Data Exchange (ETDEWEB)

    Young, D.E.; Noble, R.J.

    1989-09-01

    Fermilab plans to upgrade the Tevatron to expand the physics research program in both the fixed target and the collider operating modes. The first phase of this program is to increase the energy of the H{sup -} linac from 200 to 400 MeV in order to reduce the incoherent space change tuneshift at injection into the Booster which can limit either the brightness or the total intensity of the beam. The linac upgrade will be achieved by replacing the last four 201 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of about 8 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. 4 refs., 3 figs., 1 tab.

  14. Progress in the Development of the TOP Linac

    CERN Document Server

    Picardi, L

    2004-01-01

    The TOP Linac (Oncological Therapy with Protons), under development by ENEA and ISS is a sequence of three pulsed (5 msec, 300 Hz) linear accelerators: a 7 MeV, 425 MHz RFQ+DTL (AccSys Model PL-7), a 7–65 MeV, 2998 MHz Side Coupled Drift Tube Linac (SCDTL) and a 65–200 MeV, variable energy 2998 MHz Side Coupled Linac (SCL). The first SCDTL module is composed by 11 DTL tanks coupled by 10 side cavities. The tanks has modified to overcome vacuum leakage that occurred during brazing, and now the module has been completed, and is ready to be tested with protons. The 7 MeV injector has been recently installed in the ENEA Frascati laboratories for preliminary test, before being transferred to the main Oncologycal Hospital in Rome, Istituto Regina Elena.

  15. TLD determination of neutron dose contribution in medical linac

    Energy Technology Data Exchange (ETDEWEB)

    Cano, A.; Rivera, T.; Calderon A, J. A. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Villasenor N, L. F. [Hospital General de Mexico, Dr. Balmis No. 148, Col. Doctores, 06726 Mexico D. F. (Mexico); Vega C, H. R., E-mail: azorin@xanum.uam.m [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-02-15

    The increased use of Linacs with accelerating voltage higher than 10 MV in clinical radiotherapy is producing and increasing demand of accurate dosimetric measurements of the photon induced neutron contamination of the radiotherapy beams, due that the associated Bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. Thermal neutron fluences can be measured with TLD-600/TLD-700 pairs arranged in both a bare and a cadmium (Cd) foil covered methacry-late box. Neutron response of Tl dosemeters irradiated with two different neutron sources has been investigated. The shape of the glow curve of these TLDs after irradiation in a medical Linac and in a Pu Be neutron source has been studied to verify the contribution of neutrons to an additional dose to staff, patients and the general public, due to photonuclear reactions generating neutrons from medical Linacs. (Author)

  16. Development of Intense Beam Proton Linac in China

    CERN Document Server

    Fu, S; Ouyang Hua Fu; Zhao, S

    2004-01-01

    Study on intense beam proton linac was started about four years ago in a national program for the basic research on ADS in China. This ADS program is meant for the future development of the clean nuclear power generation. Another important application of HPPA for Chinese Spallation Neutron Source was also proposed recently in China, and it is financially supported by Chinese Academy of Sciences. In this paper, the research progress on intense beam proton linac in these two application fields will be outlined. It involves the test result of an high-current ECR proton source, construction status of a 3.5 MeV RFQ accelerator and the design of a DTL linac.

  17. Finite Element Thermal Study of the Linac4 Plasma Generatora

    CERN Document Server

    Faircloth, D; Kuchler, D; Lettry, L; Scrivens, R; CERN. Geneva. BE Department

    2010-01-01

    The temperature distribution and heat flow at equilibrium of the plasma generator of the RF-powered non-cesiated Linac4 H- ion source have been studied with a finite element model. It is shown that the equilibrium temperatures obtained in the Linac4 nominal operation mode (100 kW RF power, 2 Hz, 0.4 ms pulse duration) are within material specifications except for the magnet cage, where a redesign may be necessary. To assess the upgrade of the Linac4 source for operation in the high-power operation mode of SPL, an extrapolation of the heat load towards 100 kW RF power, 50 Hz repetition rate and 0.4 ms pulse duration has been performed. The results indicate that a significant improvement of the source cooling is required to allow for operation in HP-SPL.

  18. Physics design of a CW high-power proton Linac for accelerator ...

    Indian Academy of Sciences (India)

    The accelerator for ADS should have high efficiency and reliability and very low beam losses to allow hands-on maintenance. With these criteria, the beam dynamics simulations for a 1 GeV, 30 mA proton Linac has been done. The Linac consists of normal-conducting radio-frequency quadrupole (RFQ), drift tube linac (DTL) ...

  19. Estimates of dispersive effects in a bent NLC Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Michael Syphers and Leo Michelotti

    2000-10-31

    An alternative being considered for the Next Linear Collider (NLC) is not to tunnel in a straight line but to bend the Main Linac into an arc so as to follow a gravitational equipotential. The authors begin here an examination of the effects that this would have on vertical dispersion, with its attendant consequences on synchrotron radiation and emittance growth by looking at two scenarios: a gentle continuous bending of the beam to follow an equipotential surface, and an introduction of sharp bends at a few sites in the linac so as to reduce the maximum sagitta produced.

  20. Status of the BNL 200 MeV Linac

    Energy Technology Data Exchange (ETDEWEB)

    McNerney, A.; Brennan, J.M.; Briscoe, B.; Brodowski, J.; Horton, R.; LoDestro, V.; Montemurro, P.; Zhang, S.Y.

    1986-01-01

    The BNL 200 MeV Linac normally accelerates H/sup -/ ions during its operating schedule. During selected periods, typically of six to ten weeks duration, polarized H/sup -/ ions are accelerated. Since linac H/sup -/ commissioning, longer 7835 tube lives have been recorded and after initial operating bugs were eliminated, preinjector reliability has improved. Hardware components in the Preinjector, rf system, and ion source have been replaced or upgraded, and plans are being implemented for future system improvements. BLIP operations were initially curtailed during polarized beam running and a pulsed magnet has been installed in LEBT to restore BLIP running time to original levels.

  1. Beam position monitor for energy recovered linac beams

    Science.gov (United States)

    Powers, Thomas; Evtushenko, Pavel

    2017-06-06

    A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.

  2. Design of the LINAC4 Transfer Line Quadrupole Electromagnets

    CERN Document Server

    Vanherpe, L

    2013-01-01

    Beam focusing in the various segments of the Linac4 Transfer Line is provided by quadrupole electromagnets. In total seventeen pulsed, air-cooled quadrupole electromagnets are required. They are made of laminated electrical steel yokes and coils wound from solid copper wire. All magnets have an aperture radius of 50 mm and are required to provide an integrated field gradient of 1.8 T over a magnetic length of 300 mm. This design report summarizes the main magnetic, electrical and mechanical design parameters of the Linac4 Transfer Line Quadrupole Magnets. The effect of the vacuum chamber on the magnetic field quality and the field delay is studied.

  3. Micro-SHINE Uranyl Sulfate Irradiations at the Linac

    Energy Technology Data Exchange (ETDEWEB)

    Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States); Kalensky, Michael [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Schneider, John [Argonne National Lab. (ANL), Argonne, IL (United States); Byrnes, James [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-08-01

    Peroxide formation due to water radiolysis in a uranyl sulfate solution is a concern for the SHINE Medical Technologies process in which Mo-99 is generated from the fission of dissolved low enriched uranium. To investigate the effects of power density and fission on peroxide formation and uranyl-peroxide precipitation, uranyl sulfate solutions were irradiated using a 50-MeV electron linac as part of the micro-SHINE experimental setup. Results are given for uranyl sulfate solutions with both high and low enriched uranium irradiated at different linac powers.

  4. Influence of the Microchannel Height on the Impedance of a Flow Electrochemical Cell with Planar Interdigitated Electrodes

    Science.gov (United States)

    Kozlov, A. G.; Fadina, E. A.

    2018-01-01

    The article considers an analytical approach for determining the impedance of an electrochemical cell with planar interdigitated microelectrodes located in a microchannel and for estimation of the effect on the impedance characteristics of the microchannel height. The proposed approach is based on the use of an electric equivalent circuit of the electrochemical cell for determining its impedance and a mathematical simulation of the distribution of the electrical potential in the structure of interdigital microelectrodes located in a microchannel to determine the constant electrochemical cell. Using this approach, the analysis of impedance dependencies is performed and the frequency dependences of the real and imaginary parts, the modulus and the argument of the impedance of the electrochemical cell with the specific geometry of the interdigital microelectrodes for different microchannel heights are determined.

  5. Neutron reflectivity as a tool to study the interdigitation of grafted polymer chains and its dynamics

    Science.gov (United States)

    Leger, Liliane; Restagno, Frédéric; Cousin, Fabrice; Boue, François; Chenneviere, Alexis

    Three series of experiments aimed at characterizing the interdigitation between a brush and a melt, and based on neutron reflectivity, are presented and discussed. The density profile of brush chains has been analysed for series of annealing times, on h-PS brushes in contact with d-PS melts, as a function of molecular weights and grafting densities. We show that the relaxation dynamics of the brush chains can be modelled taking into account the long relaxation time of end tethered chains along with the reptation of the melt chains which accelerates the arm retraction process. Using a non-grafted layer with a thickness smaller than the equilibrium size of the brush when immersed into a thick melt allows one to apply chosen degrees of confinement to the brush. We show that the interdigitation dynamics is affected by such confinements, in a way reminiscent of the change of the glass transition temperature in nanometric PS films. Finally, when the upper d-PS layer is sheared above Tg, flow with large slip at the wall has been observed and interpreted in terms of stretching and expulsion of the grafted chains from the melt. We show how neutron reflectivity directly evidence this expulsion.

  6. Surface versus lateral illumination effects on an interdigitated Si planar PIN photodiode

    Science.gov (United States)

    Menon, P. S.; Shaari, Sahbudin

    2005-08-01

    The planar PIN Photodiode (PD) has profound advantages compared to the vertical surface/edge illuminated PIN PD. A two dimensional interdigitated silicon PIN PD with a 58 microns × 80 microns active area and finger width of 2 microns and finger spacing of 10 microns respectively was modeled and simulated in a novel approach using Silvaco ATHENA and ATLAS software. The device was illuminated from the surface and laterally and comparison analysis was performed. At a reverse bias of -10 V, the dark current was 1 ps. Photocurrent of 500 nA was obtained for a 5 Wcm-2 optical beam power for both the surface and lateral illumination at a -10 V reverse bias. The total quantum efficiency of the laterally illuminated PIN PD at a wavelength of 850 nm was 95% (responsivity=0.65 A/W) and 75% (responsivity=0.52 A/W) for the surface illuminated PIN PD respectively. The -3dB cutoff frequency of the surface illuminated device was at ~10 kHz and for the laterally illuminated PIN PD, the frequency was at ~0.1 MHz. Lateral illumination in an interdigitated Si planar PIN PD produces higher photocurrent contributing to higher quantum efficiency, responsivity and frequency response as compared to surface illumination.

  7. Indirect voltammetric detection of fluoride ions in toothpaste on a comb-shaped interdigitated microelectrode array.

    Science.gov (United States)

    Cernanská, Monika; Tomcík, Peter; Jánosíková, Zuzana; Rievaj, Miroslav; Bustin, Dusan

    2011-02-15

    A novel technique based on dynamic electrochemistry for the detection of fluoride ions was developed. It is based on its strong complexation with ferric ion. Formed fluoroferric complex is cathodically inactive at the potential of the reduction of free ferric aquo ion. The voltammetric and amperometric response of platinum comb-shaped interdigitated microelectrode array is decreased after fluoride addition. This decrease serves for the quantification of fluoride ions added to the solution. The detection limit of 4.5×10(-5) mol dm(-3) was achieved when one of the segments of interdigitated microelectrode array (IDA) was used as an indicating electrode. The detection limit is about one order of magnitude lower than in the case of conventional platinum macroelectrode. In comparison with ISE electrodes this method is faster and also avoiding large error resulting from the antilogarithmization of ISE Nerstian response. The method was applied to the analysis of toothpaste. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Development of Multi-Degree-Of-Freedom Piezoelectric Energy Harvester Using Interdigital Shaped Cantilevers.

    Science.gov (United States)

    Cho, Hyunok; Park, Jongcheol; Park, Jae Yeong

    2016-05-01

    A piezoelectric vibration energy harvester with interdigital shaped cantilever was developed by using silicon bulk micromachining technology. The proposed energy harvester was designed to obtain multi degree-of-freedom (m-DOF). Most of the piezoelectric vibration energy harvesters are comprised of mass-loaded cantilever beams having several resonant frequencies. The second resonant frequency of such a device has lower amplitude compared to its first resonant frequency (fundamental frequency). Therefore, the interdigital shaped cantilever has been proposed for multiple fundamental resonant frequencies. The fabricated piezoelectric vibration energy harvester is composed of main cantilever (MC), sub-main cantilever (SMC), and secondary cantilevers (SC). MC surrounds SMC and SC which have same dimension of 5600 x 800 x 10 μm3. The fabricated piezoelectric energy harvester can generate 51.4 mV(p-p) and 11 mV(p-p) of output voltages at 24.2 Hz and 33 Hz of its resonant frequencies by MC. Moreover, it can generate 8 mV(p-p) and 6.6 mV(p-p) of output voltages at 24.2 Hz and 33.2 Hz of its resonant frequencies by SMC; and 364 mV(p-p) of output voltage at 33.6 Hz of its resonant frequency by SC.

  9. Syndactyly in a novel Fras1(rdf) mutant results from interruption of signals for interdigital apoptosis.

    Science.gov (United States)

    Hines, Elizabeth A; Verheyden, Jamie M; Lashua, Amber J; Larson, Sarah C; Branchfield, Kelsey; Domyan, Eric T; Gao, Juan; Harvey, Julie F; Herriges, John C; Hu, Linghan; Mcculley, David J; Throckmorton, Kurt; Yokoyama, Shigetoshi; Ikeda, Akihiro; Xu, Guoliang; Sun, Xin

    2016-04-01

    Fras1 encodes an extracellular matrix protein that is critical for the establishment of the epidermal basement membrane during gestation. In humans, mutations in FRAS1 cause Fraser Syndrome (FS), a pleiotropic condition with many clinical presentations such as limb, eye, kidney, and craniofacial deformations. Many of these defects are mimicked by loss of Fras1 in mice, and are preceded by the formation of epidermal blisters in utero. In this study, we identified a novel ENU-derived rounded foot (rdf) mouse mutant with highly penetrant hindlimb soft-tissue syndactyly, among other structural defects. Mapping and sequencing revealed that rdf is a novel loss-of-function nonsense allele of Fras1 (Fras1(rdf)). Focusing on the limb, we found that the Fras1(rdf) syndactyly phenotype originates from loss of interdigital cell death (ICD). Despite normal expression of bone morphogenetic protein (BMP) ligands and their receptors, the BMP downstream target gene Msx2, which is also necessary and sufficient to promote ICD, was down-regulated in the interdigital regions of Fras1(rdf) hindlimb buds. The close correlation between limb bud epidermal blistering, decreased Msx2 expression, and reduced ICD in the Fras1(rdf) hindlimb buds suggests that epithelium detachment from the mesenchyme may create a physical gap that interrupts the transmission of BMP, among other signals, resulting in soft tissue syndactyly. © 2016 Wiley Periodicals, Inc.

  10. Dielectric capacitors with three-dimensional nanoscale interdigital electrodes for energy storage.

    Science.gov (United States)

    Han, Fangming; Meng, Guowen; Zhou, Fei; Song, Li; Li, Xinhua; Hu, Xiaoye; Zhu, Xiaoguang; Wu, Bing; Wei, Bingqing

    2015-10-01

    Dielectric capacitors are promising candidates for high-performance energy storage systems due to their high power density and increasing energy density. However, the traditional approach strategies to enhance the performance of dielectric capacitors cannot simultaneously achieve large capacitance and high breakdown voltage. We demonstrate that such limitations can be overcome by using a completely new three-dimensional (3D) nanoarchitectural electrode design. First, we fabricate a unique nanoporous anodic aluminum oxide (AAO) membrane with two sets of interdigitated and isolated straight nanopores opening toward opposite planar surfaces. By depositing carbon nanotubes in both sets of pores inside the AAO membrane, the new dielectric capacitor with 3D nanoscale interdigital electrodes is simply realized. In our new capacitors, the large specific surface area of AAO can provide large capacitance, whereas uniform pore walls and hemispheric barrier layers can enhance breakdown voltage. As a result, a high energy density of 2 Wh/kg, which is close to the value of a supercapacitor, can be achieved, showing promising potential in high-density electrical energy storage for various applications.

  11. Full power to the first Linac4 module

    CERN Multimedia

    Francesco Poppi

    2010-01-01

    Since last week the first of a total of 23 accelerating structures for Linac4 has been undergoing high-power tests. Although still a prototype, this structure is destined to be the first of the 12 PIMS cavities to be installed in the Linac4 tunnel and it has been completely designed, developed and constructed at CERN.   The PIMS prototype. The new Linac4 has 4 different types of accelerating structures. The PI-Mode Structures (PIMS) are the last stage and are designed to accelerate protons up to 160 MeV. “PIMS have never before been used to accelerate protons”, explains Frank Gerigk, the project engineer responsible for the Linac4 accelerating structures. “In LEP, they were used to accelerate electrons, and now we have modified them and improved several design features to make them suitable for protons”. The first prototype was entirely manufactured in the CERN workshop. Due to the size of the pieces it was difficult to achieve and preserve the required to...

  12. Study on the section-division of superconducting proton linac

    CERN Document Server

    Ouyang Hua Fu

    2002-01-01

    Study on the section-division of superconducting proton linac is carried out in detail, which includes the discussion on the principles of the division, the discussion on the symmetric division and non-symmetric division, the determination of the cell number of the superconducting cavity and the value of the geometric beta sub G

  13. Towards adaptive IMRT sequencing for the MR-linac

    NARCIS (Netherlands)

    Kontaxis, C|info:eu-repo/dai/nl/413754162; Bol, G H|info:eu-repo/dai/nl/343084309; Lagendijk, J J W|info:eu-repo/dai/nl/07011868X; Raaymakers, B W|info:eu-repo/dai/nl/229639410

    2015-01-01

    The MRI linear accelerator (MR-linac) that is currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to track the patient's target(s) and Organ(s) At Risk during radiation delivery. In this paper, we present a treatment planning system for

  14. Linac4: injecting new life into the LHC

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    Construction work is nearing completion on the ion source for Linac4, the new linear accelerator that forms part of the LHC injector upgrade programme. Here we find out more about this essential component of the accelerator chain, designed and built at CERN.     The image shows the Linac4 H- source. The red light is the alpha line of the visible hydrogen emission spectrum. The ion source is a key component of Linac4, the linear accelerator that from 2018 will supply H- ions (hydrogen atoms with an extra electron) at 160 MeV for injection into the accelerator complex. As the only ion source at CERN, Linac4 must be highly reliable, which requires a full understanding of the production mechanisms, the simulation of physical processes and the validation of those processes through experimentation. “This source is the result of much fruitful collaboration,” says Jacques Lettry of the BE department. “Its design was inspired by the many sources of th...

  15. Design and analysis of X-band femtosecond linac

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, M.; Kozawa, T.; Takeshita, A.; Kobayashi, T.; Ueda, T.; Miya, K. [Tokyo Univ., Tokai, Ibaraki (Japan). Nuclear Engineering Research Lab.

    1997-03-01

    Femtosecond quantum phenomena research project is proposed at Nuclear Engineering Research Laboratory, University of Tokyo. The research facility consists of an X-band (11.424GHz) femtosecond electron linac, a femtosecond wavelength tunable laser, two S-band (2.856GHz) picosecond electron linacs and measuring equipments. Especially, we aim to generate a 100 fs (FWHM) electron single bunch with more than 1 nC at the X-band femtosecond linac. Ultrafast processes in radiation physics, chemistry, material science and microscopic electromagnetic phenomena are going to be analyzed there. Here the design and analysis of an X-band femtosecond linac is presented. The simulation of electron dynamics is carried out including magnetic pulse compression by using PARMELA and SUPERFISH. It is found by the simulation that the 600 ps (tail-to-tail) electron emission from a 200 kV thermionic gun can be bunched and compressed to 110 fs (FWHM) with the charge of 0.8 nC which gives 7.3 kA. We plan to use one high power X-band klystron which can supply 60 MW with more than 200 ns pulse duration. The flatness of plateau of the pulse should be 0.2% for stable ultrashort bunch generation. (author)

  16. Conceptual Design of the Linac4 Main Dump

    CERN Document Server

    Leitao, I V; Maglioni, C

    2012-01-01

    Linac4 is the new CERN linear accelerator intended to replace the ageing Linac2 as the injector to the Proton Synchrotron Booster (PSB) for increasing the luminosity of the Large Hadron Collider (LHC). By delivering a 160MeV H- beam, Linac4 will provide the necessary conditions to double the brightness and intensity of the beam extracted from the PSB. This paper describes the conceptual design of the Linac4 Main Dump, where two different concepts relying respectively on water and air cooling were compared and evaluated. Based on the application of analytical models for the energy deposited by the beam, heat conduction and cooling concepts, a parametric study was performed. This approach allowed the identification of the “optimal” configuration for these two conceptual geometries and their relative comparison. Besides giving the theoretical guidelines for the design of the new dump, this work also contributes to the development of analytical tools to allow a better understanding of the influence of the se...

  17. SRF LINAC FOR FUTURE EXTENSION OF THE PEFP

    Directory of Open Access Journals (Sweden)

    HAN-SUNG KIM

    2014-04-01

    Full Text Available A study on the superconducting RF linac is underway in order to increase the beam energy up to 1 GeV by extending the Proton Engineering Frontier Project (PEFP 100-MeV linac. The operating frequency of the PEFP superconducting linac (SCL is 700 MHz, which is determined by the fact that the frequency of the existing normal conducting linac is 350 MHz. A preliminary study on the beam dynamics showed that two types of cavities with geometrical betas of 0.50 and 0.74 could cover the entire energy range from 100 MeV to 1 GeV. An inductive output tube (IOT based RF system is under consideration as a high-power RF source for the SCL due to its low operating voltage and high efficiency. As a prototyping activity for a reduced beta cavity, a five-cell cavity with a geometrical beta of 0.42 was designed and fabricated. A vertical test of the prototype cavity at low temperatures was performed to check the performance of the cavity. The design study and the prototyping activity for the PEFP SCL will be presented in this paper.

  18. Failure Modes Analysis for the MSU-RIA Driver Linac

    CERN Document Server

    Wu, Xiaoyu; Gorelov, Dmitry; Grimm, Terry L; Marti, Felix; York, Richard

    2005-01-01

    Previous end-to-end beam dynamics simulation studies* using experimentally-based input beams including alignment and rf errors and variation in charge-stripping foil thickness have indicated that the Rare Isotope Accelerator (RIA) driver linac proposed by MSU has adequate transverse and longitudinal acceptances to accelerate light and heavy ions to final energies of at least 400 MeV/u with beam powers of 100 to 400 kW. During linac operation, equipment loss due to, for example, cavity contamination, availability of cryogens, or failure of rf or power supply systems, will lead to at least a temporary loss of some of the cavities and focusing elements. To achieve high facility availability, each segment of the linac should be capable of adequate performance even with failed elements. Beam dynamics studies were performed to evaluate the linac performance under various scenarios of failed cavities and focusing elements with proper correction schemes, in order to prove the flexibility and robustness of the driver ...

  19. Conceptual Design for the New RPI 2020 Linac

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, C.; Bane, K.; Dolgashev, V.; Jensen, A.; Haase, A.; Jongewaard, E.; Kemp, M.; Krasnykh, A.; Lewandowski, J.; Li, Z.; Neilson, J.; Pearson, C.; Tantawi, S.; Wang, J.; Yeremian, A.D.; /SLAC; Brand, P.; Danon, Y.; /Rensselaer Polytech. Inst.; Epping, B.; Donovan, T.; Block, R.; Leinweber, G.; /Knolls Atomic Power Lab.

    2014-10-29

    The Rensselaer Polytechnic Institute (RPI) spectrometer is an installation based on an L-band linear accelerator designed and installed many decades ago. While this installation has served many important experiments over the decades, a new more powerful and more flexible linac to serve a wider range of experiments is envisioned as an upgrade to the existing installation by 2020.

  20. Beam dynamics of alternating-phase-focused linac

    CERN Document Server

    Iwata, Y; Kapin, V

    2004-01-01

    A simple method to find an array of synchronous phases for alternating-phase-focused (APF) linacs is presented. The phase array is described with a smooth function having free parameters. With a set of the parameters, a simulation on the beam dynamics was made and distributions of the six-dimensional phase spaces were calculated for each set of the parameters. The parameters were varied, and numbers of the simulations have been performed. An optimum set of the parameters were determined so that the simulations of the beam dynamics yield large acceptances and small emittances of the extracted beams. Since the APF linac can provide both axial and radial stability of beams just with the rf acceleration-field, no additional focusing element inside of drift tubes are necessary. Comparing with conventional linacs having focusing elements, it has advantage in construction and operation costs as well as its acceleration rate. Therefore, the APF linacs would be suited for an injector of medical synchrotrons. A practic...

  1. Post-accelerator LINAC design for the VECC RIB project

    Indian Academy of Sciences (India)

    Post-accelerator LINAC design for the VECC RIB project. ARUP BANDYOPADHYAY. Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700 064, India. Abstract. Variable Energy Cyclotron Centre (VECC) is presently developing an ISOL post- acclerator type of RIB facility. The scheme utilises the existing K.

  2. SRF LINAC for future extension of the PEFP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Sung; Kwon, Hyeok Jung; Seol, Kyoung Tae; Jang, Ji Ho; Cho, Yong Sub [Proton Engineering Frontier Project, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-04-15

    A study on the superconducting RF linac is underway in order to increase the beam energy up to 1 GeV by extending the Proton Engineering Frontier Project (PEFP) 100-MeV linac. The operating frequency of the PEFP superconducting linac (SCL) is 700 MHz, which is determined by the fact that the frequency of the existing normal conducting linac is 350 MHz. A preliminary study on the beam dynamics showed that two types of cavities with geometrical betas of 0.50 and 0.74 could cover the entire energy range from 100 MeV to 1 GeV. An inductive output tube (IOT) based RF system is under consideration as a high-power RF source for the SCL due to its low operating voltage and high efficiency. As a prototyping activity for a reduced beta cavity, a five-cell cavity with a geometrical beta of 0.42 was designed and fabricated. A vertical test of the prototype cavity at low temperatures was performed to check the performance of the cavity. The design study and the prototyping activity for the PEFP SCL will be presented in this paper.

  3. Heavy-ion LINAC development for the US RIA project

    Indian Academy of Sciences (India)

    Particle Accelerator Conference, Chicago, IL, 18–22 June 2001 (to be published) http://pacwebserver.fnal.gov/papers/Thursday/PM Oral/ROPA002.pdf. [5] K W Shepard, The U.S. RIA Project SRF LINACS, presented in the 10th Int. Workshop on RF. Superconductivity, Paper TA003, Tsukuba, Japan, 6–11 September 2001.

  4. Frequency choice of eRHIC SRF linac

    Energy Technology Data Exchange (ETDEWEB)

    Xu, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roser, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-01-05

    eRHIC is a FFAG lattice-based multipass ERL. The eRHIC SRF linac has been decided to change from 422 MHz 5-cell cavity to 647 MHz 5-cell cavity. There are several considerations affecting the frequency choice for a high-current multipass-ERL: the beam structure, bunch length, energy spread, beam-break-up (BBU) threshold, SRF loss considerations. Beyond the physics considerations, cost and complexity or risk is an important consideration for the frequency choice, especially when we are designing a machine to be built in a few years. Although there are some benefits of using a 422 MHz cavity for eRHIC ERL, however, there are some very critical drawbacks, including lack of facilities to fabricate a 422 MHz 5-cell cavity, very few facilities to process such a cavity and no existing facility to test the cavity anywhere. As the cavity size is big and its weight is large, it is difficult to handle it during fabrication, processing and testing, and no one has experience in this area. As the cavity size is large, the cryomodule becomes big as well. All of these considerations drive the risk of building eRHIC ERL with 422 MHz cavities to a very high level. Therefore, a decision was made to change the frequency of main linac to be 647 MHz 5-cell cavities. This note will compare these two linacs: 422MHz 5-cell cavity linac and 647Mz 5-cell cavity SRF linac, from both practical point of view and physics point of view.

  5. Beam halo in high-intensity hadron linacs

    Energy Technology Data Exchange (ETDEWEB)

    Gerigk, F.

    2006-12-21

    This document aims to cover the most relevant mechanisms for the development of beam halo in high-intensity hadron linacs. The introduction outlines the various applications of high-intensity linacs and it will explain why, in the case of the CERN Superconducting Proton Linac (SPL) study a linac was chosen to provide a high-power beam, rather than a different kind of accelerator. The basic equations, needed for the understanding of halo development are derived and employed to study the effects of initial and distributed mismatch on high-current beams. The basic concepts of the particle-core model, envelope modes, parametric resonances, the free-energy approach, and the idea of core-core resonances are introduced and extended to study beams in realistic linac lattices. The approach taken is to study the behavior of beams not only in simplified theoretical focusing structures but to highlight the beam dynamics in realistic accelerators. All effects which are described and derived with simplified analytic models, are tested in realistic lattices and are thus related to observable effects in linear accelerators. This approach involves the use of high-performance particle tracking codes, which are needed to simulate the behavior of the outermost particles in distributions of up to 100 million macro particles. In the end a set of design rules are established and their impact on the design of a typical high-intensity machine, the CERN SPL, is shown. The examples given in this document refer to two different design evolutions of the SPL study: the first conceptual design report (SPL I) and the second conceptual design report (SPL II). (orig.)

  6. Slot-finger superconducting structure with rf focusing

    Directory of Open Access Journals (Sweden)

    Yu. Senichev

    2005-07-01

    Full Text Available The linear accelerator based on a superconducting structure with a high accelerating gradient accordingly has a strong rf defocusing factor. Usually, a quadrupole or solenoid focusing system is used in such accelerators. Both of these systems complicate the linear accelerator. The quadrupoles are located outside the cavity and a transition between the cold and the warm systems is required. Therefore an additional drift space between cryostats is needed, which can cause parametric resonance in the longitudinal plane in the energy range of (3–20  MeV. In the system with the solenoid the high magnetic field can affect the superconductivity. We consider the novel superconducting H resonator based on the TE211 mode with a slot and rf finger, providing the high-intensity beam focusing in the large range of low energy of (3–50  MeV. Above 50 MeV we suggest using the slot structure with the external quadrupoles.

  7. Exogenous Cellulase Switches Cell Interdigitation to Cell Elongation in an RIC1-dependent Manner in Arabidopsis thaliana Cotyledon Pavement Cells.

    Science.gov (United States)

    Higaki, Takumi; Takigawa-Imamura, Hisako; Akita, Kae; Kutsuna, Natsumaro; Kobayashi, Ryo; Hasezawa, Seiichiro; Miura, Takashi

    2017-01-01

    Pavement cells in cotyledons and true leaves exhibit a jigsaw puzzle-like morphology in most dicotyledonous plants. Among the molecular mechanisms mediating cell morphogenesis, two antagonistic Rho-like GTPases regulate local cell outgrowth via cytoskeletal rearrangements. Analyses of several cell wall-related mutants suggest the importance of cell wall mechanics in the formation of interdigitated patterns. However, how these factors are integrated is unknown. In this study, we observed that the application of exogenous cellulase to hydroponically grown Arabidopsis thaliana cotyledons switched the interdigitation of pavement cells to the production of smoothly elongated cells. The cellulase-induced inhibition of cell interdigitation was not observed in a RIC1 knockout mutant. This gene encodes a Rho-like GTPase-interacting protein important for localized cell growth suppression via microtubule bundling on concave cell interfaces. Additionally, to characterize pavement cell morphologies, we developed a mathematical model that considers the balance between cell and cell wall growth, restricted global cell growth orientation, and regulation of local cell outgrowth mediated by a Rho-like GTPase-cytoskeleton system. Our computational simulations fully support our experimental observations, and suggest that interdigitated patterns form because of mechanical buckling in the absence of Rho-like GTPase-dependent regulation of local cell outgrowth. Our model clarifies the cell wall mechanics influencing pavement cell morphogenesis. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Risk factors for interdigital dermatitis and heel erosion in dairy cows kept in cubicle houses in The Netherlands

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2005-01-01

    Risk factors concerning both the pasture and housing seasons for interdigital dermatitis and heel-horn erosion (IDHE) were studied in dairy cows in a cross-sectional study in The Netherlands. The study population included 2326 cows (41 herds) and 2751 cows (46 herds) for the pasture and housing

  9. Circuit modeling on polyaniline functionalized nanowire-templated micro-interdigital capacitors for pH sensing

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, A.; Mátéfi-Tempfli, Stefan

    2011-01-01

    This study presents an improved alternative current (ac) circuit modeling of a highly sensitive capacitive pH-sensing element based on polyaniline (PANI) functionalized nanowire-templated micro-interdigited electrodes (NWs μIDEs). While electrical resonance measurements deal with a total equivalent...

  10. The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts.

    Science.gov (United States)

    van Kesteren, Z; Janssen, T M; Damen, E; van Vliet-Vroegindeweij, C

    2012-05-21

    To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10 mm leaf width MLCs, with and without interdigitating leafs, and a 5 mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10 mm leaf width MLC with and without leaf interdigitation. When comparing the 10 mm leaf width MLC with the 5 mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V(95%) was reduced by 0.02 using the thin MLC. The V(65%) of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V(95%) was equivalent for the 10 and 5 mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5 mm generates better treatment plans although the clinical relevance remains

  11. Lipid nanotube formation using space-regulated electric field above interdigitated electrodes.

    Science.gov (United States)

    Bi, Hongmei; Fu, Dingguo; Wang, Lei; Han, Xiaojun

    2014-04-22

    Lipid nanotubes have great potential in biology and nanotechnology. Here we demonstrate a method to form lipid nanotubes using space-regulated AC electric fields above coplanar interdigitated electrodes. The AC electric field distribution can be regulated by solution height above the electrodes. The ratio of field component in x axis (Ex) to field component in z axis (Ez) increases dramatically at solution height below 50 μm; therefore, at lower solution height, the force from Ex predominantly drives lipids to form lipid nanotubes along with the electric field direction. The forces exerted on the lipid nanotube during its formation were analyzed in detail, and an equation was obtained to describe the relationship among nanotube length and field frequency, amplitude, and time. We believe that the presented approach opens a way to design and prepare nanoscale materials with unique structural and functional properties using space-regulated electric fields.

  12. Improved detection limits of bacterial endotoxins using new type of planar interdigital sensors

    KAUST Repository

    Syaifudin, A. R Mohd

    2012-10-01

    New types of planar interdigital sensors were fabricated by photolithography and etching techniques on a Silicon/Silicon Dioxide (Si/SiO2) wafer (single side polished). The sensors were then coated with APTES (3-aminopropyltrietoxysilane) a cross linker used to bind Polymyxin B (PmB) molecules on electrodes surface. PmB is an antimicrobial peptide produced by the Gram-positive bacterium-Bacillus which has specific binding properties to Lipopolysaccharide (LPS). This paper will discuss the fabrication process, coating and immobilization procedures and analysis of sensors\\' performance based on Impedance Spectroscopy method. The sensor sensitivity was compared to standard ToxinSensor Chromogenic LAL Endotoxin Assay Kit for verification. © 2012 IEEE.

  13. Post annealing performance evaluation of printable interdigital capacitive sensors by principal component analysis

    KAUST Repository

    Zia, Asif Iqbal

    2015-06-01

    The surface roughness of thin-film gold electrodes induces instability in impedance spectroscopy measurements of capacitive interdigital printable sensors. Post-fabrication thermodynamic annealing was carried out at temperatures ranging from 30 °C to 210 °C in a vacuum oven and the variation in surface morphology of thin-film gold electrodes was observed by scanning electron microscopy. Impedance spectra obtained at different temperatures were translated into equivalent circuit models by applying complex nonlinear least square curve-fitting algorithm. Principal component analysis was applied to deduce the classification of the parameters affected due to the annealing process and to evaluate the performance stability using mathematical model. Physics of the thermodynamic annealing was discussed based on the surface activation energies. The post anneal testing of the sensors validated the achieved stability in impedance measurement. © 2001-2012 IEEE.

  14. Interdigitated electrode (IDE) for porcine detection based on titanium dioxide (TiO2) thin films

    Science.gov (United States)

    Nordin, N.; Hashim, U.; Azizah, N.

    2016-07-01

    Interdigited Electrode (IDE) porcine detection can be accomplished to authenticate the halal issue that has been a concern to Muslim not only in Malaysia but all around the world. The method used is photolithography that used the p-type photoresist on the spin coater with 2500 rpm. Bare IDEs device is deposited with Titanium Dioxide (TiO2) to improve the performance of the device. The result indicates that current-voltage (I-V) measurement of porcine probe line slightly above porcine target due to negative charges repelled each other. The IDE device can detect the porcine presence in food as lowest as 1.0 µM. Better performance of the device can be achieved with the replacement of gold deposited to trigger more sensitivity of the device.

  15. PECVD growth of high quality graphene on interdigital electrodes of MEMS supercapacitor

    Science.gov (United States)

    Zainal Abidin, Hafzaliza Erny; Hamzah, Azrul Azlan; Mohamed, Mohd Ambri; Majlis, Burhanuddin Yeop

    2017-08-01

    In the field of science, there is a significant interest in graphene due to its extraordinary properties such as high electrical conductivity, good electrochemical stability and excellent mechanical behavior. This paper presents the direct graphene growth on interdigital electrodes by plasma enhanced chemical vapor deposition (PECVD) using Ni catalyst and methane (CH4) as the carbon source. The 100 nm of Ni was deposited on the top of SiO2 substrate functional as catalyst and electrode of MEMS supercapacitor. The growth of graphene was investigated at temperature 1000°C at 10 minutes and at fix power of 40 Watt. The morphology and structure of as- grown graphene were characterized by Raman spectroscopy, Field Emission Scanning Electron Microscope (FESEM) and Atomic Force Microscopy (AFM). From Raman spectra, it is observed that the intensity ratio of the 2D band to G band produced a good quality bilayer graphene.

  16. Extranodal interdigitating dendritic cell sarcoma presenting in the pleura: a case report.

    Science.gov (United States)

    Han, Hye-Suk; Lee, Ok-Jun; Lim, Sung-nam; An, Jin Young; Lee, Ki Man; Choe, Kang Hyeon; Lee, Ki Hyeong; Kim, Seung Taik

    2011-02-01

    Interdigitating dendritic cell sarcoma (IDCS) is an extremely rare neoplasm arising from the antigen-presenting cells of the immune system. This disease usually involves the lymph nodes, and rarely, extranodal sites may be affected. The authors report a case of extranodal IDCS presenting in the pleura. A 32-yr-old man presented with progressive chest pain. Imaging studies showed diffuse pleural thickening with pleural effusion. Morphological and immunohistochemical analysis of an incisional biopsy of the pleura were consistent with a diagnosis of IDCS; tumor cells were positive for S100 and CD45, but negative for CD1a, CD21, CD35, B cell and T cell markers. The patient was administered chemotherapy, but died of progressive disease. Although its incidence is extremely rare, this case suggests that extranodal IDCS should be considered in the differential diagnosis of undifferentiated neoplasms and that immunohistochemical staining be performed using appropriate markers.

  17. Impedance Characterization of the Degradation of Insulating Layer Patterned on Interdigitated Microelectrode.

    Science.gov (United States)

    Lee, Gihyun; Kim, Sohee; Cho, Sungbo

    2015-10-01

    Life-time and functionality of planar microelectrode-based devices are determined by not only the corrosion-resistance of the electrode, but also the durability of the insulation layer coated on the transmission lines. Degradation of the insulating layer exposed to a humid environment or solution may cause leakage current or signal loss, and a decrease in measurement sensitivity. In this study, degradation of SU-8, an epoxy-based negative photoresist and insulating material, patterned on Au interdigitated microelectrode (IDE) for long-term (>30 days) immersion in an electrolyte at 37 °C was investigated by electrical impedance spectroscopy and theoretical equivalent circuit modeling. From the experiment and simulation results, it was found that the degradation level of the insulating layer of the IDE electrode can be characterized by monitoring the resistance of the insulating layer among the circuit parameters of the designed equivalent circuit modeling.

  18. S Sensors: Fumarate-Based fcu-MOF Thin Film Grown on a Capacitive Interdigitated Electrode

    KAUST Repository

    Yassine, Omar

    2016-10-31

    Herein we report the fabrication of an advanced sensor for the detection of hydrogen sulfide (H2S) at room temperature, using thin films of rare-earth metal (RE)-based metal-organic framework (MOF) with underlying fcu topology. This unique MOF-based sensor is made via the insitu growth of fumarate-based fcu-MOF (fum-fcu-MOF) thin film on a capacitive interdigitated electrode. The sensor showed a remarkable detection sensitivity for H2S at concentrations down to 100ppb, with the lower detection limit around 5ppb. The fum-fcu-MOF sensor exhibits a highly desirable detection selectivity towards H2S vs. CH4, NO2, H2, and C7H8 as well as an outstanding H2S sensing stability as compared to other reported MOFs. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A new multifunctional platform based on high aspect ratio interdigitated NEMS structures.

    Science.gov (United States)

    Ghatnekar-Nilsson, S; Karlsson, I; Kvennefors, A; Luo, G; Zela, V; Arlelid, M; Parker, T; Montelius, L; Litwin, A

    2009-04-29

    A multifunctional NEMS platform based on a mass-producible, surface relief grating has been developed and fabricated directly in polymer materials. The pattern consists of high aspect ratio interdigitated nanometer-sized pairs of walls and can be produced in a low-complexity one-step patterning process with nanoimprint lithography. In this paper, we demonstrate the usefulness of the platform primarily by showing an application as a high-sensitivity mass sensor in air. The sensors, which are based on the high frequency resonant response of around 200 MHz, show a mass responsivity of the order of 0.1 Hz/zg per wall at room temperature and in ambient air. Their ability to selectively adsorb airborne target molecules, such as thiols, is also demonstrated. We also show that the same device can function as a varactor for electronic circuits based on its large tunable capacitive range.

  20. A Compact Multiband BPF Using Step-impedance Resonators with Interdigital Capacitors

    Directory of Open Access Journals (Sweden)

    S. Meesomklin

    2016-06-01

    Full Text Available A compact multiband band-pass filter design for applications of GSM, Wi-MAX and WLAN systems is presented. The design is based on the resonant characteristics of step-impedance and interdigital capacitor resonators with overlap cross coupling structure. The fabricated filter has been operated at the fundamental, first and second harmonic resonant frequencies of 1.8 GHz, 3.7 GHz, and 5.2 GHz, respectively. The experimental results of the fabricated filter agree very well with the simulation expectations using IE3D package. The proposed filter has good performances, while the resonator size can be reduced from λ/2 to λ/8, resulting in the most compact multiband band-pass filter compared with the others using transmission line resonators .

  1. A clamp fixture with interdigital capacitive sensor for in situ evaluation of wire insulation

    Science.gov (United States)

    Sheldon, Robert T.; Bowler, Nicola

    2014-02-01

    An interdigital capacitive sensor has been designed and optimized for testing aircraft wires by applying a quasinumerical model developed and reported previously. The sensor consists of two patches of interdigitated electrodes, connected by a long signal bus strip, that are intended to conform to two sides of an insulated wire. The electrodes are deposited using photolithography upon a 25.4-μm-thick Kapton® polyimide film. The two electrode patches are attached to the two jaws of a plastic spring-loaded clamp, with each jaw having a milled groove designed such that the electrodes conform to the curved surface of the insulated wire. An SMA connector and cable connect between the electrodes on the clamp and an LCR meter. Segments of pristine M5086/2 aircraft wire, each 10 cm long, were immersed in fluids commonly found in aircraft environments, to cause accelerated chemical degradation. The effects of Jet A fuel, deicing fluid, hydraulic fluid, aircraft cleaner, isopropyl alcohol and distilled water were studied. The frequency-dependent capacitance and dissipation factor of one pristine wire segment and of those degraded in the six fluid environments were measured within the frequency range 100 Hz to 1 MHz. Significant changes in capacitance and dissipation factor were observed for all degraded wires, compared with results for the pristine sample, suggesting the feasibility of detecting insulation degradation in the field. The results were also consistent with those of a similar experiment performed on sheets of Nylon 6, the material that comprises the outermost layer of M5086/2 wire.

  2. Differential expression of Toll-like receptors and inflammatory cytokines in ovine interdigital dermatitis and footrot

    Science.gov (United States)

    Davenport, Rebecca; Heawood, Christopher; Sessford, Kate; Baker, Melissa; Baiker, Kerstin; Blacklaws, Barbara; Kaler, Jasmeet; Green, Laura; Tötemeyer, Sabine

    2014-01-01

    Footrot is a common inflammatory bacterial disease affecting the health and welfare of sheep worldwide. The pathogenesis of footrot is complex and multifactorial. The primary causal pathogen is the anaerobic bacterium Dichelobacter nodosus, with Fusobacterium necrophorum also shown to play a key role in disease. Since immune-mediated pathology is implicated, the aim of this research was to investigate the role of the host response in interdigital dermatitis (ID) and footrot. We compared the expression of Toll-like receptors (TLRs) and pro-inflammatory cytokines and the histological appearance of clinically normal in comparison to ID and footrot affected tissues. Severe ID and footrot were characterised by significantly increased transcript levels of pro-inflammatory cytokines TNFα and IL1β and the pattern recognition receptors TLR2 and TLR4 in the interdigital skin. This was reflected in the histopathological appearance, with ID and footrot presenting progressive chronic-active pododermatitis with a mixed lymphocytic and neutrophilic infiltration, gradually increasing from a mild form in clinically normal feet, to moderate in ID and to a focally severe form with frequent areas of purulence in footrot. Stimulation with F. necrophorum and/or D. nodosus extracts demonstrated that dermal fibroblasts, the resident cell type of the dermis, also contribute to the inflammatory response to footrot bacteria by increased expression of TNFα, IL1β and TLR2. Overall, ID and footrot lead to a local inflammatory response given that expression levels of TLRs and IL1β were dependent on the disease state of the foot not the animal. PMID:25124770

  3. Treatment of Signs and Symptoms (Pruritus) of Interdigital Tinea Pedis With Econazole Nitrate Foam, 1.

    Science.gov (United States)

    Hoffman, Lauren K; Raymond, Isabelle; Kircik, Leon

    2018-02-01

    Tinea pedis is the most common dermatophyte infection. Treatment is critical to alleviate pruritic symptoms, to reduce the risk for secondary bacterial infection, and to limit the spread of infection to other body sites or other individuals. The objective of this study was to compare the abilities of econazole nitrate topical foam, 1% and ketoconazole cream (2%) to reduce pruritus, thus improving quality of life, and to determine patient preference for the foam product versus the cream product in patients with interdigital tinea pedis. A single-center, investigator-blinded, observational pilot study was conducted to compare econazole nitrate topical foam (1%) to ketoconazole cream (2%). In this split-body study, 20 subjects received both econazole nitrate topical foam and ketoconazole cream and applied the medications daily to either the right or left foot for 14 days. Improvements in patient quality of life (pruritus) and patient preference were measured using the pruritus visual analog scale (VAS), Skindex-16, and patient preference questionnaires. Nineteen subjects completed the study and one subject was lost to follow-up. Reductions in VAS scores of econazole nitrate topical foam were significantly greater than those of ketoconazole cream, indicating the superiority of the econazole nitrate foam in reducing pruritus. Skindex-16 data showed significant reductions in total scores and individual domains, including patient symptom, emotional, and functional domains, by the final visit. Since each subject received both medications the questionnaire was not medication-specific. Responses to patient preference questionnaires showed that econazole nitrate topical foam,1% was rated as "good" or "excellent" in all measures assessed. One adverse event was noted. In patients with interdigital tinea pedis, application of econazole nitrate topical foam 1% twice daily for two weeks was clinically effective and significantly superior to ketoconazole cream 2% in reducing

  4. Leak Propagation Dynamics for the HIE-ISOLDE Superconducting Linac

    CERN Document Server

    Ady, M; Kersevan, R; Vandoni, G; Ziemianski, D

    2014-01-01

    In order to cope with space limitations of existing infrastructure, the cryomodules of the HIE-ISOLDE superconducting linac feature a common insulation and beam vacuum, imposing the severe cleanliness standard of RF cavities to the whole cryostat. Protection of the linac vacuum against air-inrush from the three experimental stations through the HEBT (High Energy Beam Transport) lines relies on fast valves, triggered by fast cold cathode gauges. To evaluate the leak propagation velocity as a function of leak size and geometry of the lines, a computational and experimental investigation is being carried out at CERN. A 28 m long tube is equipped with cold-cathode gauges. A leak is opened by the effect of a cutting pendulum, equipped with an accelerometer for data acquisition triggering, on a thin aluminium window. The air inrush dynamics is simulated by Finite Elements fluid dynamics in the viscous regime.

  5. The CLIC Positron Capture and Acceleration in the Injector Linac.

    CERN Document Server

    Vivoli, Alessandro; Chehab, Robert; Dadoun, Olivier; Lepercq, Pierre; Poirier, Freddy; Rinolfi, Louis; Strakhovenko, Vladimir; Variola, Alessandro

    2010-01-01

    The baseline of the CLIC study considers non-polarized e+ for the 3 TeV centre of mass energy. The e+ source is based on the hybrid targets scheme, where a crystal-radiator target is followed by an amorphous-converter target. Simulations have been performed from the exit of the amorphous target up to the entrance of the Pre-Damping Ring. Downstream the amorphous target, there is an Adiabatic Matching Device (AMD) followed by a Pre-Injector Linac accelerating the e+ beam up to around 200 MeV. Then a common Injector Linac (for both e+ and e-) accelerates the beams up to 2.86 GeV before being injected into the Pre-Damping Ring. In this note, the characteristics of the AMD and the other sections are described and the beam parameters at the entrance of the Pre-Damping Ring are given.

  6. PROSPECTS FOR A VERY HIGH POWER CW SRF LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Robert Rimmer

    2010-06-01

    Steady development in SRF accelerator technology combined with the success of large scale installations such as CEBAF at Jefferson Laboratory and the SNS Linac at ORNL gives credibility to the concept of very high average power CW machines for light sources or Proton drivers. Such machines would be powerful tools for discovery science in themselves but could also pave the way to reliable cost effective drivers for such applications as neutrino factories, an energy-frontier muon collider, nuclear waste transmutation or accelerator driven subcritical reactors for energy production. In contrast to machines such as ILC that need maximum accelerating gradient, the challenges in these machines are mainly in efficiency, reliability, beam stability, beam loss and of course cost. In this paper the present state of the art is briefly reviewed and options for a multi-GeV, multi-MW CW linac are discussed.

  7. Development of RF System Model for CERN Linac2 Tanks

    CERN Document Server

    Joshi, G; Vretenar, M; Kumar, G; Agarwal, V

    2010-01-01

    An RF system model has been created for the CERN Linac2 Tanks. RF systems in this linac have both single and double feed architectures. The main elements of these systems are: RF power amplifier, main resonator, feed-line and the amplitude and phase feedback loops. The model of the composite system is derived by suitably concatenating the models of these individual sub-systems. For computational efficiency the modeling has been carried out in the base band. The signals are expressed in in-phase - quadrature domain, where the response of the resonator is expressed using two linear differential equations, making it valid for large signal conditions. MATLAB/SIMULINK has been used for creating the model. The model has been found useful in predicting the system behaviour, especially during the transients. In the paper we present the details of the model, highlighting the methodology, which could be easily extended to multiple feed RF systems.

  8. Commissioning of the LINAC4 Ion Source Transverse Emittance Meter

    CERN Document Server

    Bravin, E; Dutriat, C; Lokhovitsky, A; Raich, U; Roncarolo, F; Scrivens, R; Zorin, E

    2010-01-01

    LINAC4 is the first step in the upgrade of the injector chain for the LHC, and will accelerate H- ions from 45 keV to 160 MeV. Currently the ion source is installed in a test setup and its commissioning started at the end of 2009. A slit-grid system is used to measure the transverse emittance of the beam at the exit of the source. The results of the measurements have been compared with analytical and numerical predictions of the performance of the emittance meter, addressing the system resolution, accuracy and sensitivity. The outcome of this analysis has been used to improve the design of a new slit-grid system foreseen for the commissioning of LINAC 4 at higher energy locations.

  9. Linac4 Low Energy Beam Measurements with Negative Hydrogen

    CERN Document Server

    Scrivens, R; Crettiez, O; Dimov, V; Gerard, D; Granemann Souza, E; Guida, R; Hansen, J; Lallement, J B; Lettry, J; Lombardi, A; Midttun, O; Pasquino, C; Raich, U; Riffaud, B; Roncarolo, F; Valerio-Lizarraga, C A; Wallner, J; Yarmohammadi Satri, M; Zickler, T

    2014-01-01

    Linac4, a 160 MeV normal-conducting H- linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H- beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

  10. Minimizing Energy Spread In The REX/HIE-ISOLDE Linac

    CERN Document Server

    Yucemoz, Mert

    2017-01-01

    This report tries to minimize the energy spread of the beam at the end of the REX-HIE-ISOLDE Linac using the last RF cavity as a buncher. Beams with very low energy spread are often required by the users of the facility In addition, one of the main reason to have minimum energy spread in longitudinal phase space is that higher beam energy spread translates in to a position spread after interacting with target. This causes an overlap in the position of different particles that makes it difficult to distinguish them. Hence, in order to find the operation settings for minimum energy spread at the end of the REX-HIE-ISOLDE linac and to inspect the ongoing physics, several functions on Matlab were created that runs beam dynamics program called “TRACKV39” that provides some graphs and values as a result for analysis.

  11. Depolarization in the ILC Linac-To-Ring Positron beamline

    Energy Technology Data Exchange (ETDEWEB)

    Kovalenko, Valentyn; Ushakov, Andriy [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Moortgat-Pick, Gudrid [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Riemann, Sabine [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2012-02-15

    To achieve the physics goals of future Linear Colliders, it is important that electron and positron beams are polarized. The positron source planned for the International Linear Collider (ILC) is based on a helical undulator system and can deliver a polarised beam with vertical stroke Pe{sup +} vertical stroke {>=} 60%. To ensure that no significant polarization is lost during the transport of the electron and positron beams from the source to the interaction region, spin tracking has to be included in all transport elements which can contribute to a loss of polarization. These are the positron source, the damping ring, the spin rotators, the main linac and the beam delivery system. In particular, the dynamics of the polarized positron beam is required to be investigated. The results of positron spin tracking and depolarization study at the Positron-Linac-To-Ring (PLTR) beamline are presented. (orig.)

  12. High Voltage Installation of PS Linac 1 Preinjector

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The high-voltage installation of the linac 1 preinjector in its house-sized Faraday cage. Originally driven by a 520 kV Cockcroft-Walton generator, at the time of this picture the HV came from a 520 kV SAMES generator. The column in the front carries a capacitor. The cubicle in the right background is the electronics platform (see 7403120). The round structure at left houses the ion source, from where the protons (and sometimes other ions), electrostatically accelerated to 520 keV, enter the Alvarez structure of linac 1, to be accelerated to 50 MeV. Jean-Luc Vallet is busy with servicing the installation. See also 7403064X, 7403066X.

  13. Suppression of microbunching instability in the linac coherent light source

    Directory of Open Access Journals (Sweden)

    Z. Huang

    2004-07-01

    Full Text Available A microbunching instability driven by longitudinal space charge, coherent synchrotron radiation, and linac wakefields is studied for the linac coherent light source (LCLS accelerator system. Since the uncorrelated (local energy spread of electron beams generated from a photocathode rf gun is very small, the microbunching gain may be large enough to significantly amplify rf-gun generated modulations or even shot-noise fluctuations of the electron beam. The uncorrelated energy spread can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the free-electron laser performance. We study different damping options in the LCLS and discuss an effective laser heater to minimize the impact of the instability on the quality of the electron beam.

  14. Energy feedback system for the PLS-II linac

    Science.gov (United States)

    Kim, Changbum; Kim, Mungyung; Hwang, Ilmoon; Choi, Jae-Young; Shin, Seunghwan; Kim, Sung Chul; Park, Chongdo

    2017-12-01

    The upgraded Pohang-Light-Source (PLS-II) was opened to the public in 2012. Among many improvements of the PLS-II, a top-up operation was one of the highlights of them, and the stability of the electron beam was improved significantly. For the top-up operation, a stable injection from the linac to the storage ring was critically important, so that an energy feedback system was introduced to reduce the energy jitter of the linac electron beam. The result of the feedback system was successful and the measured energy jitter was less than ±0.1% (rms). In this work, the details of the energy feedback system are presented. It includes the setup for the energy feedback system, measurement results in the optimization process, and the future work for a better performance.

  15. Spectral fluence of neutrons generated by radiotherapeutic linacs.

    Science.gov (United States)

    Králík, Miloslav; Šolc, Jaroslav; Vondráček, Vladimir; Šmoldasová, Jana; Farkašová, Estera; Tichá, Ivana

    2015-02-01

    Spectral fluences of neutrons generated in the heads of the radiotherapeutic linacs Varian Clinac 2100 C/D and Siemens ARTISTE were measured by means of the Bonner spheres spectrometer whose active detector of thermal neutrons was replaced by an activation detector, i.e. a tablet made of pure manganese. Measurements with different collimator settings reveal an interesting dependence of neutron fluence on the area defined by the collimator jaws. The determined neutron spectral fluences were used to derive ambient dose equivalent rate along the treatment coach. To clarify at which components of the linac neutrons are mainly created, the measurements were complemented with MCNPX calculations based on a realistic model of the Varian Clinac. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. High-Energy Ion Linacs Based on Spoke Cavities

    CERN Document Server

    Shephard, K W; Ostromov, P N

    2003-01-01

    The applicability of superconducting TEM-class spoke cavities to high-energy ion linacs is discussed, and detailed designs for two TEM-class, triple-spoke-loaded superconducting niobium resonant cavities are presented. The 345 MHz cavities have a velocity range of 0.4linac is discussed in detail.

  17. Assessment of Alternative RF Linac Structures for APT

    Energy Technology Data Exchange (ETDEWEB)

    None

    1997-03-26

    The APT program has been examining both normal and superconducting variants of the APT linac for the past two years. A decision on which of the two will be the selected technology will depend upon several considerations including the results of ongoing feasibility experiments, the performance and overall attractiveness of each of the design concepts, and an assessment of the system-level features of both alternatives. The primary objective of the Assessment of Alternative RF Linac Structures for APT study reported herein was to assess and compare, at the system-level, the performance, capital and life cycle costs, reliability/availability/maintainability (RAM) and manufacturing schedules of APT RF linear accelerators based upon both superconducting and normal conducting technologies. A secondary objective was to perform trade studies to explore opportunities for system optimization, technology substitution and alternative growth pathways and to identify sensitivities to design uncertainties.

  18. Beam forming system modernization at the MMF linac proton injector

    CERN Document Server

    Derbilov, V I; Nikulin, E S; Frolov, O T

    2001-01-01

    The isolation improvements of the beam forming system (BFS) of the MMF linac proton injector ion source are reported. The mean beam current and,accordingly, BFS electrode heating were increased when the MMF linac has began to operate regularly in long beam sessions with 50 Hz pulse repetition rate. That is why the BFS electrode high-voltage isolation that was made previously as two consequently and rigidly glued solid cylinder insulators has lost mechanical and electric durability. The substitution of large (160 mm) diameter cylinder insulator for four small diameter (20 mm) tubular rods has improved vacuum conditions in the space of beam forming and has allowed to operate without failures when beam currents being up to 250 mA and extraction and focusing voltage being up to 25 and 40 kV respectively. Moreover,the construction provides the opportunity of electrode axial move. The insulators are free from electrode thermal expansion mechanical efforts in a transverse direction.

  19. Control system by the technological electron Linac KUT-20

    CERN Document Server

    Akchurin, Y I; Gurin, V A; Demidov, N V

    2001-01-01

    The high-power technological electron linac KUT-20 was developed at the Science Research Complex 'Accelerator' of NSC KIPT. The linac consists of two 1.2 m length accelerating structures with a variable geometry and an injector. The latter comprises a diode electron gun,a klystron type buncher and an accelerating cavity.With a RF supply power at accelerating structure entries of 11 MW and with a current at the accelerator exit of 1A,the beam energy will be up to 20 MeV.An average beam power is planned to be 20 kW.All systems of the accelerator are controlled by a computerised control system. The program and technical complex consist of PC equipped with fast ADC control console, synchronization unit, microprocessor-operated complexes.

  20. An intense ECR ion source for proton linac

    CERN Document Server

    Cui Bao Qun; Bao Yi We; Jiang Wei; Wang Rong

    2002-01-01

    An intense electron cyclotron resonance ion source for proton linac has been developed. At 30 keV, 100 mA hydrogen beam is extracted from the source. The proton ratio is greater than 85% and the beam density of 340 mA/Cm sup 2 is achieved. The rms emittance of the beam is around 0.11 pi mm centre dot mrad. The source has passed 100 h reliability test

  1. Linac Coherent Light Source (LCLS) Design Study Report

    Energy Technology Data Exchange (ETDEWEB)

    Cornacchia, Massimo

    1998-12-04

    The Stanford Linear Accelerator Center, in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. Starting in FY 1998, the first two-thirds of the SLAC linac will be used for injection into the B factory. This leaves the last one-third free for acceleration to 15 GeV. The LCLS takes advantage of this opportunity, opening the way for the next generation of synchrotron light sources with largely proven technology and cost effective methods. This proposal is consistent with the recommendations of the Report of the Basic Energy Sciences Advisory Committee (Synchrotron Radiation Light Source Working Group, October 18-19, 1997). The report recognizes that ''fourth-generation x-ray sources...will in all likelihood be based on the free electron laser concepts. If successful, this technology could yield improvements in brightness by many orders of magnitude.'' This Design Study, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac. Although this design is based on a consistent and feasible set of parameters, some components require more research and development to guarantee the performance. Given appropriate funding, this R and D phase can be completed in 2 years.

  2. High duty factor plasma generator for CERN's Superconducting Proton Linac.

    Science.gov (United States)

    Lettry, J; Kronberger, M; Scrivens, R; Chaudet, E; Faircloth, D; Favre, G; Geisser, J-M; Küchler, D; Mathot, S; Midttun, O; Paoluzzi, M; Schmitzer, C; Steyaert, D

    2010-02-01

    CERN's Linac4 is a 160 MeV linear accelerator currently under construction. It will inject negatively charged hydrogen ions into CERN's PS-Booster. Its ion source is a noncesiated rf driven H(-) volume source directly inspired from the one of DESY and is aimed to deliver pulses of 80 mA of H(-) during 0.4 ms at a 2 Hz repetition rate. The Superconducting Proton Linac (SPL) project is part of the luminosity upgrade of the Large Hadron Collider. It consists of an extension of Linac4 up to 5 GeV and is foreseen to deliver protons to a future 50 GeV synchrotron (PS2). For the SPL high power option (HP-SPL), the ion source would deliver pulses of 80 mA of H(-) during 1.2 ms and operate at a 50 Hz repetition rate. This significant upgrade motivates the design of the new water cooled plasma generator presented in this paper. Its engineering is based on the results of a finite element thermal study of the Linac4 H(-) plasma generator that identified critical components and thermal barriers. A cooling system is proposed which achieves the required heat dissipation and maintains the original functionality. Materials with higher thermal conductivity are selected and, wherever possible, thermal barriers resulting from low pressure contacts are removed by brazing metals on insulators. The AlN plasma chamber cooling circuit is inspired from the approach chosen for the cesiated high duty factor rf H(-) source operating at SNS.

  3. Design and Construction of the Linac4 Accelerating Structures

    CERN Document Server

    Gerigk, F; Dallocchio, A; Favre, G; Vretenar, M; Wegner, R; Tirado, P Ugena; Rossi, C; Riffaud, B; Ramberger, S; Polini, M; Gentini, L; Geisser, JM; Giguet, JM; Mathot, S; Naumenko, M; Kendjebulatov, E; Tribendis, A; Kryuchkov, Ya

    2013-01-01

    The Linac4 project at CERN is at an advanced state of construction. Prototypes and/or operational modules of the different types of accelerating structures (RFQ, buncher, DTL, CCDTL, and PIMS) have been built and are presently tested. This paper gives the status of the cavity production and reviews the RF and mechanical design of the various structure types. Furthermore the production experience and the first test results shall be presented.

  4. Linac Coherent Light Source (LCLS) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Nuhn, Heinz-Dieter

    2002-11-25

    The Stanford Linear Accelerator Center, in collaboration with Argonne National Laboratory, Brookhaven National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, have collaborated to create a conceptual design for a Free-Electron-Laser (FEL) R&D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. The first two-thirds of the SLAC linac are used for injection into the PEP-II storage rings. The last one-third will be converted to a source of electrons for the LCLS. The electrons will be transported to the SLAC Final Focus Test Beam (FFTB) Facility, which will be extended to house a 122-m undulator system. In passing through the undulators, the electrons will be bunched by the force of their own synchrotron radiation to produce an intense, spatially coherent beam of x-rays, tunable in energy from 0.8 keV to 8 keV. The LCLS will include two experiment halls as well as x-ray optics and infrastructure necessary to make use of this x-ray beam for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac.

  5. ANU LINAC upgrade using multi-stub resonators

    Indian Academy of Sciences (India)

    A proposal has been prepared to upgrade the LINAC at ANU, using re-plated PbSn split loop resonators performing at 3.6 MV/m, and the addition of two- and three-stub resonators. The system is designed to provide 6 MeV/a.m.u. 107Ag starting with gas-stripped beam from the 14 UD, which is then foil-stripped before the ...

  6. Linac4 Beam Characterization before Injection into the CERN PS Booster

    CERN Document Server

    Mikulec, B; Eshraqi, M; Hanke, K; Hermanns, T; Lombardi, A M; Raich, U

    2010-01-01

    Construction work for the new CERN linear accelerator, Linac4, started in October 2008. Linac4 will replace the existing Linac2 and provide an H− beam at 160 MeV (as opposed to the present 50 MeV proton beam) for injection into the CERN PS Booster (PSB). The charge-exchange H− injection combined with the higher beam energy will allow for an increase in beam brightness required for reaching the ultimate LHC luminosity. Commissioning of Linac4 and of the transfer line to the PSB is planned for the last quarter of 2012. Appropriate beam instrumentation is foreseen to provide transverse and longitudinal beam characterization at the exit of Linac4 and in two dedicated measurement lines located before injection into the PSB. A detailed description of the diagnostics set, especially of spectrometer and emittance meter, and the upgrade of the measurement lines for Linac4 commissioning and operation is presented.

  7. Design development of the SCDTL structure for the TOP linac

    CERN Document Server

    Picardi, L; Spataro, B

    1999-01-01

    The Side Coupled Drift Tube Linac (SCDTL) is an attractive 3 GHz accelerating structure composed of short DTL tanks coupled together by side coupling cavities, in the course of development of the 200 MeV proton linear accelerator for proton therapy planned for the Terapia Oncologica con Protoni (TOP) program of the Italian National Institute of Health (Istituto Superiore di Sanita, ISS). The TOP Linac will be used to boost to 70 MeV the 7 MeV proton beam from a linac injector. Our main concern is to investigate in detail the characteristics of the structure in terms of RF properties of the accelerating mode, like longitudinal and transverse shunt impedance and quality factor, and of the other modes that cause the origin of the tank dispersion curve, in order to stabilize the behaviour under operating conditions. Calculations performed with the computer three-dimensional (3D) codes MAFIA and SOPRANO on the smallest unit of the system (a single DTL tank without coupling cavities) and experimental measurements m...

  8. Recent improvements to software used for optimization of SRF linacs

    Energy Technology Data Exchange (ETDEWEB)

    Powers, Tom J. [JLAB

    2014-12-01

    This work describes a software tool that allows one to vary parameters and understand the effects on the optimized costs of construction plus 10 year operations of an SRF linac, where operation costs includes the cost of the electrical utilities but not the labor or other costs. The program includes estimates for the associated cryogenic facility, and controls hardware. The software interface provides the ability to vary the cost of the different aspects of the machine as well as to change the cryomodule and cavity types. Additionally, this work will describe the recent improvements to the software that allow one to estimate the costs of energy-recovery based linacs and to enter arbitrary values of the low field Q0 and Q0 slope. The initial goal when developing the software was to convert a spreadsheet format to a graphical interface and to allow the ability to sweep different parameter sets. The tools also allow one to compare the cost of the different facets of the machine design and operations so as to better understand tradeoffs. An example of how it was used to independently investigate cost optimization tradeoffs for the LCLS-II linac will also be presented.

  9. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Hatayama, A; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; Nishida, K; O’Neil, M; Ohta, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Shibata, T; Steyaert, D; Thaus, N; Yamamoto, T

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator and chopper of Linac4.

  10. Design development of the SCDTL structure for the TOP linac

    Science.gov (United States)

    Picardi, L.; Ronsivalle, C.; Spataro, B.

    1999-04-01

    The Side Coupled Drift Tube Linac (SCDTL) is an attractive 3 GHz accelerating structure composed of short DTL tanks coupled together by side coupling cavities, in the course of development of the 200 MeV proton linear accelerator for proton therapy planned for the Terapia Oncologica con Protoni (TOP) program of the Italian National Institute of Health (Istituto Superiore di Sanità, ISS). The TOP Linac will be used to boost to 70 MeV the 7 MeV proton beam from a linac injector. Our main concern is to investigate in detail the characteristics of the structure in terms of RF properties of the accelerating mode, like longitudinal and transverse shunt impedance and quality factor, and of the other modes that cause the origin of the tank dispersion curve, in order to stabilize the behaviour under operating conditions. Calculations performed with the computer three-dimensional (3D) codes MAFIA and SOPRANO on the smallest unit of the system (a single DTL tank without coupling cavities) and experimental measurements made on a prototype have shown good agreement. Two possible supporting stem configurations (single stem and two stems 180° apart for each drift tube) were examined and a comparison of the results in both cases are discussed.

  11. Optimization of Steering Elements in the RIA Driver Linac

    CERN Document Server

    SchnirmanLessner, Eliane; Ostroumov, Peter

    2005-01-01

    The driver linac of the projected RIA facility is a versatile accelerator, a 1.4-GV, CW superconducting linac designed to simultaneously accelerate several heavy-ion charge states, providing beams from protons at about 1 GeV to uranium at 400 MeV/u at power levels at a minimum of 100 kW and up to 400 kW for most beams. Acceleration of multiple-charge-state uranium beams places stringent requirements on the linac design. A steering algorithm was derived that fulfilled the driver’s real estate requirements, such as placement of steering dipole coils on SC solenoids and of beam position monitors outside cryostats, and beam-dynamics requirements, such as coupling effects induced by the focusing solenoids.* The algorithm has been fully integrated in the tracking code TRACK** and is used to study and optimize the number and position of steering elements that minimize the multiple-beam centroid oscillations and preserve the beam emittance under misalignments of accelerating and transverse focusing elements...

  12. Optimization of Beam Transmission of PAL-PNF Electron Linac

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kim, S. K.; Kim, E. A. [Pohang University of Science and Technology, Pohang (Korea, Republic of)

    2012-05-15

    The PNF (Pohang Neutron Facility) electron Linac is providing converted neutrons and photons from electron beams to users for nuclear physics experiments and high energy gamma-ray exposures. This linac is capable of producing 100 MeV electron beams with a beam current of pulsed 100 mA. The pulse length is 2 {mu}s and the pulse repetition rate is typically 30 Hz. This linac consists of two SLAC-type S-band accelerating columns and the thermionic RF gun. They are powered by one klystron and the matching pulse modulator. The electron beams emitted from the RF gun are bunched as they pass through the alpha magnet and are injected into the accelerating column thereafter. In this paper, we discuss procedures and results of the beam transmission optimization with technical details of the accelerator system. We also briefly discuss the future upgrade plan to obtain short-pulse or electron beams for neutron TOF experiments by adopting a triode type thermionic DC electron gun

  13. Linac Coherent Light Source (LCLS) Conceptual Design Report

    CERN Document Server

    Nuhn, H D

    2002-01-01

    The Stanford Linear Accelerator Center, in collaboration with Argonne National Laboratory, Brookhaven National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, have collaborated to create a conceptual design for a Free-Electron-Laser (FEL) RandD facility operating in the wavelength range 1.5-15 (angstrom). This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. The first two-thirds of the SLAC linac are used for injection into the PEP-II storage rings. The last one-third will be converted to a source of electrons for the LCLS. The electrons will be transported to the SLAC Final Focus Test Beam (FFTB) Facility, which will be extended to house a 122-m undulator system. In passing through the undulators, the electrons will be bunched by the force of their own synchrotron radiatio...

  14. Electron linac for medical isotope production with improved energy efficiency and isotope recovery

    Science.gov (United States)

    Noonan, John; Walters, Dean; Virgo, Matt; Lewellen, John

    2015-09-08

    A method and isotope linac system are provided for producing radio-isotopes and for recovering isotopes. The isotope linac is an energy recovery linac (ERL) with an electron beam being transmitted through an isotope-producing target. The electron beam energy is recollected and re-injected into an accelerating structure. The ERL provides improved efficiency with reduced power requirements and provides improved thermal management of an isotope target and an electron-to-x-ray converter.

  15. Alternative Main Linac BNS Configuration for Reduced IP Energy Spread (LCC-0139)

    Energy Technology Data Exchange (ETDEWEB)

    Tenenbaum, P

    2004-05-24

    We present a series of alternate BNS phase configurations for the 500 GeV CM NLC main linac in which the energy spread at the end of the linac is reduced from its nominal 0.25% value. The energy spectrum, achievable IP beam energy, energy bias, and linac stability are evaluated for the alternate cases. We conclude that the RMS energy spread and energy bias in the NLC can easily be reduced but that modest reductions in CM energy are required.

  16. Numerical simulations of stripping effects in high-intensity hydrogen ion linacs

    Directory of Open Access Journals (Sweden)

    J.-P. Carneiro

    2009-04-01

    Full Text Available Numerical simulations of H^{-} stripping losses from blackbody radiation, electromagnetic fields, and residual gas have been implemented into the beam dynamics code TRACK. Estimates of the stripping losses along two high-intensity H^{-} linacs are presented: the Spallation Neutron Source linac currently being operated at Oak Ridge National Laboratory and an 8 GeV superconducting linac currently being designed at Fermi National Accelerator Laboratory.

  17. Stereotactic LINAC radiosurgery for the treatment of brainstem cavernomas

    Energy Technology Data Exchange (ETDEWEB)

    Fuetsch, M.; El Majdoub, F.; Hoevels, M.; Sturm, V.; Maarouf, M. [Koeln Univ. (Germany). Dept. of Stereotaxy and Functional Neurosurgery; Mueller, R.P. [Koeln Univ. (Germany). Dept. of Radiation Oncology

    2012-04-15

    Background: The management of deep-seated cerebral cavernous malformations (CCMs) is still controversial. Although surgery remains the treatment of choice in patients with recurrent hemorrhage, patients with CCMs located in the brainstem are in many cases not eligible for resection due to high procedure-related morbidity and mortality. We evaluated the long-term outcome of LINAC radiosurgery (LINAC-RS) for the treatment of brainstem CCMs. Patients and methods: Between December 1992 and March 2008, 14 patients (6 men, 8 women) harboring brainstem CCMs underwent LINAC-RS. Pretreatment neuroimaging showed no associated developmental venous angiomas (DVAs) in any of our patients. Prior to treatment, all patients suffered at least from one symptomatic hemorrhage (median 1.8, range 1-3). A median follow-up of 7.1 years (range 2.0-16.8 years) could be obtained in 12 patients. We applied a median tumor surface dose of 13.9 Gy (range 11-18 Gy; median tumor volume 1.6 ml, range 0.4-4.3 ml). Results: Following LINAC-RS, neurological outcome improved in 4 (33.3%) and remained unchanged in 8 patients (66.7%). Rebleeding with subsequent transient neurological status deterioration occurred in 4 patients (33.3%), leading to additional surgical resection in 2 patients (16.7%). The corresponding annual hemorrhage rate was 4.8% (4/82.8 patient-years). Adverse radiation effects (ARE, defined by perilesional hyperintensity on T{sub 2}-weighted MR images) were revealed in 3 patients (25%), leading to transient neurological deficits in 2 patients (16.7%). There were no procedure-related complications leading to either permanent morbidity or mortality. Conclusion: Our results support the role of LINAC-RS as an efficient and safe treatment to significantly reduce the annual hemorrhage rate in patients suffering from brainstem CCMs not eligible to microsurgery. Compared with radiosurgery for arteriovenous malformations (AVMs), the intervention-related morbidity is higher. (orig.)

  18. High Power test for the first PIMS Cavity for LINAC4

    CERN Document Server

    Gerigk, F; Giguet, J M; Wegner, R

    2011-01-01

    The first cavity of the PI Mode Structure (PIMS) section of Linac4 has been high power tested at Linac4 conditions and under high average power to simulate the operating conditions of Linac4 as a high duty cycle injector for the SPL. The PIMS section consists of 12 seven cell cavities, which accelerate the Linac4 beam from 102 MeV to 160 MeV at an RF frequency of 352.2 MHz. The cell length is constant per cavity but is adapted to the particle speed from cavity to cavity.

  19. Technical Note: A novel interdigital transparent thin-film detector for medical dosimetry.

    Science.gov (United States)

    Brivio, Davide; Sajo, Erno; Zygmanski, Piotr

    2017-05-01

    A new type of thin-film interdigital detector (TFID) for medical dosimetry is investigated. The focus of this study was to characterize the detector response as a function of detector geometry in an attempt to optimize it and to understand the underlying radio-electrical effects leading to signal formation. We characterize the detector response to kilovoltage x-ray beams used in fluoroscopy and computed tomography. Each element (pixel) of the detector is composed of conductive intercombing digits deposited on a thin-film dielectric substrate by nanofabrication or using a printing process. The detector is practically transparent to x-ray radiation, yet it generates sufficient signal for many types of medical dosimetry and quality assurance tasks. The thin-film detector has negligible surface mass density (about 2.5 mg/cm2 for a 1-μm-thick Cu TFID on 12.5-μm-thick Kapton substrate) and it is conformable to curved geometries found in the medical x-ray equipment or on patient skin surface. The prototype detectors were made using glass and Kapton substrates with copper-copper and copper-aluminum interdigits. Although in principle the detector can be operated without any external bias voltage when the digits are made of disparate materials (e.g., Cu-Al), we also characterized the detector properties under small electric fields via its current-voltage curve (IV curve). Using 120 kVp, 25 mA x-ray beam with 10V external bias, the Cu-Cu detector response was about 0.2 nA/cm2 . We also measured a one-dimensional transmitted dose profile for a phantom under fluoroscopic x-rays and found relatively good agreement with a commercial photodiode (XR R12-0191, IBA Dosimetry). We demonstrated the potential of TFID detectors for kilovoltage dosimetry and we defined its optimal geometry. For digits made of the same material and for digit width equal to the separation between them, we found that the thin-film detector has optimal performance when the distance between the digit centers

  20. Preliminary design studies of a 100 MeV $H^{-}H^{+}$ LINAC as injector for SNS synchrotron/ADS LINAC

    CERN Document Server

    Pande, S A; Kulkarni, N S; Hannurkar, P R

    2002-01-01

    It is proposed to construct a spallation neutron source (SNS) at Centre for Advanced Technology (CAT) based on a 1 GeV proton synchrotron with 100 MeV H/sup -/ LINAC as injector. Additionally, the LINAC can form the first 100 MeV part of a 1 GeV proton LINAC to be built in future for accelerator driven system (ADS) applications. We are exploring a configuration of the 100 MeV LINAC which will consist of an H/sup -/ ion source, a 4-6 MeV RFQ followed either by a 20 MeV drift tube LINAC (DTL) and 100 MeV separated function drift tube LINAC (SDTL) or a coupled cavity drift tube LINAC (CCDTL) structure. In this paper, we present the results of our preliminary physics design studies of the RFQ-SDTL, RFQ-CCDTL and RFQ-DTL-SDTL configurations. The design of the 4.5 MeV RFQ is discussed along with the matching sections between the RFQ-SDTL/DTL and RFQ-CCDTL. The choice of the accelerator configuration and that of various parameters of the individual accelerator structures under consideration are discussed. The design...

  1. Expression of Fas, FasL, caspase-8 and other factors of the extrinsic apoptotic pathway during the onset of interdigital tissue elimination

    Czech Academy of Sciences Publication Activity Database

    Budišová Švandová, Eva; Veselá, Barbora; Lesot, Hervé; Poliard, A.; Matalová, Eva

    2017-01-01

    Roč. 147, č. 4 (2017), s. 497-510 ISSN 0948-6143 Institutional support: RVO:67985904 Keywords : interdigital * forelimb development * apoptosis Subject RIV: ED - Physiology Impact factor: 2.553, year: 2016

  2. Titanium Dioxide Nanoparticle-Based Interdigitated Electrodes: A Novel Current to Voltage DNA Biosensor Recognizes E. coli O157:H7

    National Research Council Canada - National Science Library

    Nadzirah, Sh; Azizah, N; Hashim, Uda; Gopinath, Subash C B; Kashif, Mohd

    2015-01-01

    .... In the present study, we have generated and examined the potential of titanium dioxide (TiO2) crystalline nanoparticles with aluminium interdigitated electrode biosensor to specifically detect single-stranded E.coli O157:H7 DNA...

  3. Humidity sensing using vertically oriented arrays of ReS2 nanosheets deposited on an interdigitated gold electrode

    Science.gov (United States)

    Yang, Aijun; Gao, Jian; Li, Baichang; Tan, Jiawei; Xiang, Yu; Gupta, Tushar; Li, Lu; Suresh, Shravan; Idrobo, Juan Carlos; Lu, Toh-Ming; Rong, Mingzhe; Koratkar, Nikhil

    2016-12-01

    We report a novel humidity sensor featuring vertically oriented arrays of ReS2 nanosheets grown on an interdigitated gold electrode by chemical vapor deposition. The vertical orientation of the nanosheets is important since it maximizes the exposed surface area for water adsorption/desorption. We find that the resistance of the ReS2 film decreases sensitively with increasing relative humidity, which we attribute to charge transfer from the absorbed H2O molecules to the n-doped ReS2 nanosheets. In addition to high sensitivity, the ReS2 sensors exhibit fast response/recovery time and excellent reversibility with minimal hysteresis. Moreover, our fabrication approach involving the direct (1-step) growth of the ReS2 films on an interdigitated electrode (without any transfer using wet chemistry or lithography) greatly simplifies the device architecture and has important practical benefits for the low-cost and scalable deployment of such sensor devices.

  4. Micro-supercapacitors based on interdigital electrodes of reduced graphene oxide and carbon nanotube composites with ultrahigh power handling performance

    Energy Technology Data Exchange (ETDEWEB)

    Beidaghi, Majid; Wang, Chunlei [Department of Mechanical and Materials Engineering, Florida International University, 10555 W. Flagler St., EC 3463, FL 33174 (United States)

    2012-11-07

    A novel method for fabricating micro-patterned interdigitated electrodes based on reduced graphene oxide (rGO) and carbon nanotube (CNT) composites for ultra-high power handling micro-supercapacitor application is reported. The binder-free microelectrodes were developed by combining electrostatic spray deposition (ESD) and photolithography lift-off methods. Without typically used thermal or chemical reduction, GO sheets are readily reduced to rGO during the ESD deposition. Electrochemical measurements show that the in-plane interdigital design of the microelectrodes is effective in increasing accessibility of electrolyte ions in-between stacked rGO sheets through an electro-activation process. Addition of CNTs results in reduced restacking of rGO sheets and improved energy and power density. Cyclic voltammetry (CV) measurements show that the specific capacitance of the micro-supercapacitor based on rGO-CNT composites is 6.1 mF cm{sup -2} at 0.01 V s{sup -1}. At a very high scan rate of 50 V s{sup -1}, a specific capacitance of 2.8 mF cm{sup -2} (stack capacitance of 3.1 F cm{sup -3}) is recorded, which is an unprecedented performance for supercapacitors. The addition of CNT, electrolyte-accessible and binder-free microelectrodes, as well as an interdigitated in-plane design result in a high-frequency response of the micro-supercapacitors with resistive-capacitive time constants as low as 4.8 ms. These characteristics suggest that interdigitated rGO-CNT composite electrodes are promising for on-chip energy storage application with high power demands. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. [Comparison of the effects of two walk-through footbaths on the prevalence of digital dermatitis and interdigital dermatitis on a commercial dairy farm].

    Science.gov (United States)

    Jorritsm, R; Lansink, B J G; Döpfer, D

    2007-01-01

    This field trial was designed to evaluate the effect of treatment with copper chelate or formalin walk-through footbaths on the prevalence of digitalis dermatitis and interdigital dermatitis on a dairy farm. Although there was no difference in effect between the two types of footbath, the probability that interdigital dermatitis improved or remained stable was lower with the copper chelate footbath than with the formalin footbath.

  6. ROP GTPase-mediated auxin signaling regulates pavement cell interdigitation in Arabidopsis thaliana.

    Science.gov (United States)

    Lin, Deshu; Ren, Huibo; Fu, Ying

    2015-01-01

    In multicellular plant organs, cell shape formation depends on molecular switches to transduce developmental or environmental signals and to coordinate cell-to-cell communication. Plants have a specific subfamily of the Rho GTPase family, usually called Rho of Plants (ROP), which serve as a critical signal transducer involved in many cellular processes. In the last decade, important advances in the ROP-mediated regulation of plant cell morphogenesis have been made by using Arabidopsis thaliana leaf and cotyledon pavement cells. Especially, the auxin-ROP signaling networks have been demonstrated to control interdigitated growth of pavement cells to form jigsaw-puzzle shapes. Here, we review findings related to the discovery of this novel auxin-signaling mechanism at the cell surface. This signaling pathway is to a large extent independent of the well-known Transport Inhibitor Response (TIR)-Auxin Signaling F-Box (AFB) pathway, and instead requires Auxin Binding Protein 1 (ABP1) interaction with the plasma membrane-localized, transmembrane kinase (TMK) receptor-like kinase to regulate ROP proteins. Once activated, ROP influences cytoskeletal organization and inhibits endocytosis of the auxin transporter PIN1. The present review focuses on ROP signaling and its self-organizing feature allowing ROP proteins to serve as a bustling signal decoder and integrator for plant cell morphogenesis. © 2014 Institute of Botany, Chinese Academy of Sciences.

  7. Mathematical Modeling of an Active-Fiber Composite Energy Harvester with Interdigitated Electrodes

    Directory of Open Access Journals (Sweden)

    A. Jemai

    2014-01-01

    Full Text Available The use of active-fiber composites (AFC instead of traditional ceramic piezoelectric materials is motivated by flexibility and relatively high actuation capacity. Nevertheless, their energy harvesting capabilities remain low. As a first step toward the enhancement of AFC’s performances, a mathematical model that accurately simulates the dynamic behavior of the AFC is proposed. In fact, most of the modeling approaches found in the literature for AFC are based on finite element methods. In this work, we use homogenization techniques to mathematically describe piezoelectric properties taking into consideration the composite structure of the AFC. We model the interdigitated electrodes as a series of capacitances and current sources linked in parallel; then we integrate these properties into the structural model of the AFC. The proposed model is incorporated into a vibration based energy harvesting system consisting of a cantilever beam on top of which an AFC patch is attached. Finally, analytical solutions of the dynamic behavior and the harvested voltage are proposed and validated with finite element simulations.

  8. Analysis of different coating thickness on new type of planar interdigital sensors for endotoxin detection

    KAUST Repository

    Syaifudin, A. R Mohd

    2013-05-01

    New types of planar interdigital sensors have been fabricated on Silicon/Silicon Dioxide (Si/SiO2) wafers. The sensors were coated with pre-cursor silica functionalized with APTES (3-aminopropyltrietoxysilane) at different thicknesses. All sensors were then immobilized with Polymyxin, B (PmB). PmB is an antimicrobial peptide produced by the Gram-positive bacterium-Bacillus, has been immobilized on the coated sensors because of its specific binding properties to endotoxin. Studies were conducted to analyze the effect of different thicknesses of coatings on the sensitivity and selectivity of the sensors. It was observed sensors coated with 3 layers of coating has better sensitivity and selectivity to the target molecules (endotoxin) compared to sensors with 5 layers of coating. The repeatability and stability of the coated sensors were tested by multiple standard endotoxin measurement and it was observed that the sensors give a good reproducibility and stability up to six continuous measurements before the coating degrades. © 2013 IEEE.

  9. Lasing in a nematic liquid crystal cell with an interdigitated electrode system

    Energy Technology Data Exchange (ETDEWEB)

    Shtykov, N M; Palto, S P; Umanskii, B A; Geivandov, A R [Shubnikov Institute of Crystallography, Russian Academy of Sciences, Moscow (Russian Federation)

    2015-04-30

    Waveguide lasing in a layer of a dye-doped nematic liquid crystal has been observed. The liquid-crystal layer was sandwiched between a quartz substrate and a glass cover plate on whose surface was deposited an interdigitated electrode system. This system had a period of 3.75 μm and played a dual role, namely, it created a spatial periodicity of the waveguide medium refractive index (thus creating distributed feedback) and served as a diffraction grating coupling out a part of waveguide radiation into the glass cover plate. The distributed feedback ensured lasing in the 18th diffraction order for the TE modes and in the 19th order for the TM modes of the waveguide. The generated radiation was observed at the exit from the glass plate end face at the angles to the waveguide plane of 33.1 ± 1.5° for TM modes and 21.8 ± 1.8° for TE modes. The intensity and position of the TE emission line showed no regular dependence on the voltage on the electrodes. In the case of TM radiation, an increase in the voltage led to a short-wavelength shift of the laser line and to a decrease in its intensity. (lasers)

  10. Single Interdigital Transducer Approach for Gravimetrical SAW Sensor Applications in Liquid Environments

    Directory of Open Access Journals (Sweden)

    Vu Hoa Nguyen

    2017-12-01

    Full Text Available Surface acoustic wave (SAW devices are well known for mass-sensitive sensor applications. In biosensing applications, chemical and biochemically evoked binding processes on surfaces are detected in liquid environments using delay line or resonator sensor configurations, preferably in combination with the appropriate microfluidic devices. All configurations share the common feature of analyzing the transmission characteristic of the propagating SAW. In this paper, a novel SAW-based impedance sensor type is introduced which uses only one interdigital transducer (IDT, simultaneously as the SAW generator and the sensor element. Here, the input port reflection coefficient S11 is measured at the IDT instead of the commonly used S21 transmission forward gain parameter. Thus, a sharp and distinct peak of the S11 spectrum is obtained, enabling a comfortable direct readout of the sensor signal. Proof of the concept was gained by analyzing the specific binding of the 4-mercaptophenylacetic acid gold nanoparticles (MPA–AuNP directly to the IDT surface. The corresponding binding kinetic of the MPA–AuNP on the functionalized gold surface has been analyzed and a sensitivity of 7.4 mΩ nM−1 has been determined.

  11. Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon Seok; Niazi, Javed H. [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of); Gu, Man Bock [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of)], E-mail: mbgu@korea.ac.kr

    2009-02-23

    An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates.

  12. Interdigitation between Triglycerides and Lipids Modulates Surface Properties of Lipid Droplets.

    Science.gov (United States)

    Bacle, Amélie; Gautier, Romain; Jackson, Catherine L; Fuchs, Patrick F J; Vanni, Stefano

    2017-04-11

    Intracellular lipid droplets (LDs) are the main cellular site of metabolic energy storage. Their structure is unique inside the cell, with a core of esterified fatty acids and sterols, mainly triglycerides and sterol esters, surrounded by a single monolayer of phospholipids. Numerous peripheral proteins, including several that were previously associated with intracellular compartments surrounded by a lipid bilayer, have been recently shown to target the surface of LDs, but how they are able to selectively target this organelle remains largely unknown. Here, we use atomistic and coarse-grained molecular dynamics simulations to investigate the molecular properties of the LD surface and to characterize how it differs from that of a lipid bilayer. Our data suggest that although several surface properties are remarkably similar between the two structures, key differences originate from the interdigitation between surface phospholipids and core neutral lipids that occurs in LDs. This property is extremely sensitive to membrane undulations, unlike in lipid bilayers, and it strongly affects both lipid-packing defects and the lateral pressure profile. We observed a marked change in overall surface properties for surface tensions >10 mN/m, indicative of a bimodal behavior. Our simulations provide a comprehensive molecular characterization of the unique surface properties of LDs and suggest how the molecular properties of the surface lipid monolayer can be modulated by the underlying neutral lipids. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  13. Plasma Immersion Ion Implantation for Interdigitated Back Passivated Contact (IBPC) Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    Young, David L.; Nemeth, William; LaSalvia, Vincenzo; Page, Matthew R.; Theingi, San; Young, Matthew; Aguiar, Jeffery; Lee, Benjamin G.; Stradins, Paul

    2016-11-21

    We present progress to develop low-cost interdigitated back contact solar cells with pc-Si/SiO2/c-Si passivated contacts formed by plasma immersion ion implantation (PIII). PIII is a lower-cost implantation technique than traditional beam-line implantation due to its simpler design, lower operating costs, and ability to run high doses (1E14-1E18 cm-2) at low ion energies (20 eV-10 keV). These benefits make PIII ideal for high throughput production of patterned passivated contacts, where high-dose, low-energy implantations are made into thin (20-200 nm) a-Si layers instead of into the wafer itself. For this work symmetric passivated contact test structures grown on n-Cz wafers with PH3 PIII doping gave implied open circuit voltage (iVoc) values of 730 mV with Jo values of 2 fA/cm2. Samples doped with B2H6 gave iVoc values of 690 mV and Jo values of 24 fA/cm2, outperforming BF3 doping, which gave iVoc values in the 660-680 mV range. Samples were further characterized by photoluminescence and SIMS depth profiles. Initial IBPC cell results are presented.

  14. Simulations of Interdigitated Electrode Interactions with Gold Nanoparticles for Impedance-Based Biosensing Applications

    Directory of Open Access Journals (Sweden)

    Scott MacKay

    2015-09-01

    Full Text Available In this paper, we describe a point-of-care biosensor design. The uniqueness of our design is in its capability for detecting a wide variety of target biomolecules and the simplicity of nanoparticle enhanced electrical detection. The electrical properties of interdigitated electrodes (IDEs and the mechanism for gold nanoparticle-enhanced impedance-based biosensor systems based on these electrodes are simulated using COMSOL Multiphysics software. Understanding these properties and how they can be affected is vital in designing effective biosensor devices. Simulations were used to show electrical screening develop over time for IDEs in a salt solution, as well as the electric field between individual digits of electrodes. Using these simulations, it was observed that gold nanoparticles bound closely to IDEs can lower the electric field magnitude between the digits of the electrode. The simulations are also shown to be a useful design tool in optimizing sensor function. Various different conditions, such as electrode dimensions and background ion concentrations, are shown to have a significant impact on the simulations.

  15. Reduced Graphene Oxide Modified the Interdigitated Chain Electrode for an Insulin Sensor

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Yagati

    2016-01-01

    Full Text Available Insulin is a key regulator in glucose homeostasis and its deficiency or alternations in the human body causes various types of diabetic disorders. In this paper, we present the development of a reduced graphene oxide (rGO modified interdigitated chain electrode (ICE for direct capacitive detection of insulin. The impedance properties of rGO-ICE were characterized by equivalent circuit modeling. After an electrochemical deposition of rGO on ICE, the electrode was modified with self-assembled monolayers and insulin antibodies in order to achieve insulin binding reactions. The impedance spectra and capacitances were measured with respect to the concentrations of insulin and the capacitance change (ΔC was analyzed to quantify insulin concentration. The antibody immobilized electrode showed an increment of ΔC according to the insulin concentration in human serum ranging from 1 ng/mL to 10 µg/mL. The proposed sensor is feasible for label-free and real-time measuring of the biomarker and for point-of-care diagnosis.

  16. Reduced Graphene Oxide Modified the Interdigitated Chain Electrode for an Insulin Sensor.

    Science.gov (United States)

    Yagati, Ajay Kumar; Park, Jinsoo; Cho, Sungbo

    2016-01-15

    Insulin is a key regulator in glucose homeostasis and its deficiency or alternations in the human body causes various types of diabetic disorders. In this paper, we present the development of a reduced graphene oxide (rGO) modified interdigitated chain electrode (ICE) for direct capacitive detection of insulin. The impedance properties of rGO-ICE were characterized by equivalent circuit modeling. After an electrochemical deposition of rGO on ICE, the electrode was modified with self-assembled monolayers and insulin antibodies in order to achieve insulin binding reactions. The impedance spectra and capacitances were measured with respect to the concentrations of insulin and the capacitance change (ΔC) was analyzed to quantify insulin concentration. The antibody immobilized electrode showed an increment of ΔC according to the insulin concentration in human serum ranging from 1 ng/mL to 10 µg/mL. The proposed sensor is feasible for label-free and real-time measuring of the biomarker and for point-of-care diagnosis.

  17. Design and fabrication of capacitive interdigitated electrodes for smart gas sensors

    KAUST Repository

    Omran, Hesham

    2016-09-05

    In this paper, we study the design parameters of capacitive interdigitated electrodes (IDEs) and the effect of these parameters on the sensitivity of the IDEs when employed as a capacitive gas sensor. Finite element simulations using COMSOL Multiphysics were carried out to evaluate the sensitivity of the capacitive sensor. Simulations show that for permittivity-based sensing, the optimum thickness of the sensing film is slightly more than half the wavelength of the IDEs structure. On the other hand, sensing films that are thinner than half wavelength should be used if the required sensing mechanism is based on structural swelling. Increasing the IDEs metal thickness can increase the sensitivity by increasing the sidewall electric field, but this is only true if the sensing film is thick enough to completely fill the spacing between the electrodes. A simple and reliable IDEs structure and fabrication process are proposed. Physical dry etching provides good yield and fine resolution compared to liftoff technique. Fabricated and packaged prototype sensors are presented. © 2015 IEEE.

  18. Self-assembled three-dimensional and compressible interdigitated thin-film supercapacitors and batteries

    Science.gov (United States)

    Nyström, Gustav; Marais, Andrew; Karabulut, Erdem; Wågberg, Lars; Cui, Yi; Hamedi, Mahiar M.

    2015-05-01

    Traditional thin-film energy-storage devices consist of stacked layers of active films on two-dimensional substrates and do not exploit the third dimension. Fully three-dimensional thin-film devices would allow energy storage in bulk materials with arbitrary form factors and with mechanical properties unique to bulk materials such as compressibility. Here we show three-dimensional energy-storage devices based on layer-by-layer self-assembly of interdigitated thin films on the surface of an open-cell aerogel substrate. We demonstrate a reversibly compressible three-dimensional supercapacitor with carbon nanotube electrodes and a three-dimensional hybrid battery with a copper hexacyanoferrate ion intercalating cathode and a carbon nanotube anode. The three-dimensional supercapacitor shows stable operation over 400 cycles with a capacitance of 25 F g-1 and is fully functional even at compressions up to 75%. Our results demonstrate that layer-by-layer self-assembly inside aerogels is a rapid, precise and scalable route for building high-surface-area 3D thin-film devices.

  19. Characterization methodology for lead zirconate titanate thin films with interdigitated electrode structures

    Science.gov (United States)

    Nigon, R.; Raeder, T. M.; Muralt, P.

    2017-05-01

    The accurate evaluation of ferroelectric thin films operated with interdigitated electrodes is quite a complex task. In this article, we show how to correct the electric field and the capacitance in order to obtain identical polarization and CV loops for all geometrical variants. The simplest model is compared with corrections derived from Schwartz-Christoffel transformations, and with finite element simulations. The correction procedure is experimentally verified, giving almost identical curves for a variety of gaps and electrode widths. It is shown that the measured polarization change corresponds to the average polarization change in the center plane between the electrode fingers, thus at the position where the electric field is most homogeneous with respect to the direction and size. The question of maximal achievable polarization in the various possible textures, and compositional types of polycrystalline lead zirconate titanate thin films is revisited. In the best case, a soft (110) textured thin film with the morphotropic phase boundary composition should yield a value of 0.95Ps, and in the worst case, a rhombohedral (100) textured thin film should deliver a polarization of 0.74Ps.

  20. Interdigitated microelectrode based impedance biosensor for detection of salmonella enteritidis in food samples

    Science.gov (United States)

    Kim, G.; Morgan, M.; Hahm, B. K.; Bhunia, A.; Mun, J. H.; Om, A. S.

    2008-03-01

    Salmonella enteritidis outbreaks continue to occur, and S. enteritidis-related outbreaks from various food sources have increased public awareness of this pathogen. Conventional methods for pathogens detection and identification are labor-intensive and take days to complete. Some immunological rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown great potential for the rapid detection of foodborne pathogens. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on avidin-biotin binding on the surface of the IME to form an active sensing layer. To increase the sensitivity of the sensor, three types of sensors that have different electrode gap sizes (2 μm, 5 μm, 10 μm) were fabricated and tested. The impedimetric biosensor could detect 103 CFU/mL of Salmonella in pork meat extract with an incubation time of 5 minutes. This method may provide a simple, rapid and sensitive method to detect foodborne pathogens.

  1. Direct protein detection with a nano-interdigitated array gate MOSFET.

    Science.gov (United States)

    Tang, Xiaohui; Jonas, Alain M; Nysten, Bernard; Demoustier-Champagne, Sophie; Blondeau, Franoise; Prévot, Pierre-Paul; Pampin, Rémi; Godfroid, Edmond; Iñiguez, Benjamin; Colinge, Jean-Pierre; Raskin, Jean-Pierre; Flandre, Denis; Bayot, Vincent

    2009-08-15

    A new protein sensor is demonstrated by replacing the gate of a metal oxide semiconductor field effect transistor (MOSFET) with a nano-interdigitated array (nIDA). The sensor is able to detect the binding reaction of a typical antibody Ixodes ricinus immunosuppressor (anti-Iris) protein at a concentration lower than 1 ng/ml. The sensor exhibits a high selectivity and reproducible specific detection. We provide a simple model that describes the behavior of the sensor and explains the origin of its high sensitivity. The simulated and experimental results indicate that the drain current of nIDA-gate MOSFET sensor is significantly increased with the successive binding of the thiol layer, Iris and anti-Iris protein layers. It is found that the sensor detection limit can be improved by well optimizing the geometrical parameters of nIDA-gate MOSFET. This nanobiosensor, with real-time and label-free capabilities, can easily be used for the detection of other proteins, DNA, virus and cancer markers. Moreover, an on-chip associated electronics nearby the sensor can be integrated since its fabrication is compatible with complementary metal oxide semiconductor (CMOS) technology.

  2. RF reference distribution system for J-PARC linac

    Science.gov (United States)

    Kobayashi, T.; Chishiro, E.; Anami, S.; Yamaguchi, S.; Michizono, S.

    2008-01-01

    The linac used by the Japan Proton Accelerator Research Complex (J-PARC) is a high-intensity proton linac with a peak current of 50 mA. The error in the accelerating field needs to be maintained within ±1% in amplitude and ±1° in phase. Thus, high phase stability is required for the RF reference distribution system. Our objective is to maintain the phase stability of the reference to less than ±0.3°. The beam quality or intensity of a proton linac strongly depends on the stability of the accelerating fields of each cavity; therefore, the stability of the RF reference distribution system is essential for the performance of the J-PARC linac. A highly stable and unique RF reference distribution system was developed for the J-PARC linac. A 12-MHz RF reference signal is converted into an optical signal and amplified by an optical amplifier. Then it is distributed through optical fiber links to 60 low-level RF control systems comprising klystron and solid-state amplifier driving systems. Phase-stabilized optical fiber (PSOF) is employed in the optical transfer line. The thermal coefficient of the PSOF transmission time was measured: its value was 0.4 ppm/°C. This property is insufficient for the required stability; accordingly, the temperature change in the PSOF should be controlled to be within ±0.5 °C by means of a cooling water system. New stable and low-jitter optical-to-electric (O/E) and electric-to-optical (E/O) converters were developed for this linac. The O/E converter is so compact that is can be mounted on a compact PCI board: its temperature is maintained constant by a Peltie device. A pulse driver (limiting amplifier) is introduced in the E/O and O/E converters for signal modulation to reduce the detection jitters. It transforms the 12-MHz signal into a rectangular wave: its the rise time is shorter than 200 ps. Then, a low-transfer jitter of 0.8 ps (rms) was obtained in the optical link of the E/O and O/E converters. The installation of the RF

  3. Dedicated Linac for Radioneurosurgery at the National Institute of Neurology and Neurosurgery of Mexico

    Science.gov (United States)

    Celis-López, Miguel A.; Lárraga-Gutiérrez, José M.

    2003-09-01

    The objective is to present a description and the main clinical applications of this dedicated Linac for benign and malignant tumors in the central nervous system. The Novalis (BrainLab, Germany) is a 6 MV dedicated linac for a single high dose Radiosurgery (RS) and for fractionated doses in Stereotactic Radiotherapy with a high level of precision at the isocenter.

  4. Nuclear burning-up of RAW in blanket of linac-driven

    Energy Technology Data Exchange (ETDEWEB)

    Beljakov, M.S.; Logashev, O.N.; Lopatkin, A.V.; Tocheny, L.V.; Khrjastov, H.A.; Blagovolin, P.P.; Kazaritsky, V.D.

    1993-12-31

    The progress in the field of designing and constructing a heavy-current proton linear accelerator became noticeable last year and allows one to count on large-scale industrial linac application. Symbiosis of linac and subcritical reactor as target has new opportunities for energetics. This accelerator concept is described.

  5. Preliminary design studies of a 100 MeV H-/H+LINAC as injector for ...

    Indian Academy of Sciences (India)

    Preliminary design studies of a 100 MeV H-/H+LINAC as injector for SNS synchrotron/ADS LINAC. S A PANDE, MOONOOKU PRASAD, NITA KULKARNI and P R HANNURKAR. Centre for Advanced Technology, Indore 452 013, India. Abstract. It is proposed to construct a spallation neutron source (SNS) at Centre for ...

  6. WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

    Energy Technology Data Exchange (ETDEWEB)

    Xing, L [Stanford University, Stanford, CA (United States); Wong, J [Johns Hopkins University, Baltimore, MD (United States); Li, R [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

  7. Beam dynamics studies in the driver LINAC pre-stripper section of ...

    Indian Academy of Sciences (India)

    ) indepen- dently phased rf cavities. The LINAC is designed to accelerate simultaneously several charge-state beams to generate as much as 400 kW of uranium beam power. The LINAC beam dynamics is most sensitive to the focusing and ...

  8. Preliminary design studies of-/H+LINAC as injector for SNS ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 59; Issue 5. Preliminary design studies of a 100 MeV H-/H+ LINAC as injector for SNS synchrotron/ADS LINAC ... In this paper, we present the results of our preliminary physics design studies of the RFQ–SDTL, RFQ–CCDTL and RFQ–DTL–SDTL configurations.

  9. Release the beams! - Linac4 ready to hit the 50 MeV mark

    CERN Document Server

    Katarina Anthony

    2015-01-01

    The Linac4 accelerator is now prepared to reach 50 MeV. This milestone energy - expected in the coming weeks - will allow the machine to act as a replacement for the ageing Linac2, four years before it takes over at the head of the accelerator chain in 2020.    Inside the Linac4 tunnel, the final DTL cavities will guide beams to 50 MeV.  (Image: Stephan Russenschuck.) The Linac4 accelerator will bring H- ion beams (hydrogen atoms with an extra electron) up to 160 MeV for injection into the PS Booster. As a key part of the LHC injector upgrade programme, Linac4 will allow the PS Booster to double its beam brightness, which will contribute to increasing the LHC’s luminosity. Linac4 will soon bring beams up to 50 MeV - the current energy delivered by the Linac2 accelerator. This milestone follows on from another recent accomplishment: the installation and commissioning of the final Drift Tube Linac (DTL) tank. Using an innovati...

  10. Preinjector for Linac 1, inside the Faraday cage

    CERN Multimedia

    1974-01-01

    For a description of the Linac 1 preinjector, please see first 7403070X. Here, the view is towards the upper level of the Faraday cage. Far to the right, a technician is peering through the service door. The huge box-shaped cubicle is the electronics platform, at 520 kV potential during operation. The "bull eye" at the left back sits at the top end of the accelerating column (see 7403081X) and houses the ion source with its electronics (see 7403083X). The SAMES generator, providing the 520 kV HV (7403074) sits on the floor and is not visible here.

  11. On structure design for the CLIC Booster Linac

    CERN Document Server

    Darvish, Esmat

    2015-01-01

    Using the SUPERFISH code we present a design for a traveling wave (TW) structure of the Booster Linac for CLIC. The structure, consisting of thirty asymmetric cells attached to the beam pipes at two ends, works in 2π/3 operating mode at working frequency 2 GHz. For the corresponding operating mode and frequency, the RF field configuration transmitted through the cavity is obtained. The results are prepared in an RF field data file to be used in the PARMELA code for further beam dynamic study.

  12. RADIATION PROTECTION OF LINAC BUNKERS. A USER-FRIENDLY APPROACH

    DEFF Research Database (Denmark)

    Holten Sørensen, Thyge; Olsen, Kjeld Jørgen; Behrens, Claus Flensted

    2015-01-01

    A well-known but complex formalism for the calculation of the leakage dose at the entrance of the linac maze was considered and simplified. These simplifications were based partly on the literature and partly on the authors' own measurements. The authors have included photon scatter originating f...... from the irradiated patient in the formalism. A formalism for two different types of bunkers was developed, and the authors have obtained simple formulas to calculate the dose at the maze entrance for both bunker types....

  13. Energy-Recovery Linacs for Commercial Radioisotope Production

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Muplus, Inc., Newport News, VA (United States)

    2016-11-19

    Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently, a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities

  14. Data systems for the Linac coherent light source.

    Science.gov (United States)

    Thayer, J; Damiani, D; Ford, C; Dubrovin, M; Gaponenko, I; O'Grady, C P; Kroeger, W; Pines, J; Lane, T J; Salnikov, A; Schneider, D; Tookey, T; Weaver, M; Yoon, C H; Perazzo, A

    2017-01-01

    The data systems for X-ray free-electron laser (FEL) experiments at the Linac coherent light source (LCLS) are described. These systems are designed to acquire and to reliably transport shot-by-shot data at a peak throughput of 5 GB/s to the offline data storage where experimental data and the relevant metadata are archived and made available for user analysis. The analysis and monitoring implementation (AMI) and Photon Science ANAlysis (psana) software packages are described. Psana is open source and freely available.

  15. Improved Overhead Accounting in the NLC Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Tenenbaum, P.

    2004-06-10

    The NLC main linac contains 1,116 RF power units, of which 5% are considered ''spares'' for replacement of failed power units, make-up of the energy gain during an RF breakdown, and energy feedback. A more careful accounting for the effects of beam loading indicates that the NLC can operate with less BNS overhead and a smaller mean phase offset than was originally specified, and that as a consequence the total number of spares is actually about 7.9% of the total.

  16. Low-{beta} SC linacs : past, present, and future.

    Energy Technology Data Exchange (ETDEWEB)

    Bollinger, L. M.

    1998-11-18

    This paper is a general review of superconducting low-{beta} technology and applications from its beginning in 1969 into the near-term future. The emphasis is on studies of accelerating resonators and on SC linacs that boost the energy of heavy-ion beams from tandem electrostatic accelerators used for nuclear-physics research. Other topics are positive-ion SC injectors to replace tandems and the need for accelerating structures with {beta} outside of the present proven range, 0.008 < {beta} < 0.2.

  17. A simulation study on the electrical structure of interdigitated back-contact silicon solar cells

    Science.gov (United States)

    Kang, Min Gu; Song, Hee-eun; Kim, Soo Min; Kim, Donghwan

    2015-05-01

    In this paper, a simulation for interdigitated back-contact (IBC) silicon solar cells was performed by using Silvaco TCAD ATLAS to investigate the cell's electrical properties. The impacts of various parameters, including the depth of the front surface field(FSF), the FSF peak doping concentration, the depths of the emitter and the back surface field(BSF), the peak doping concentrations of the emitter and BSF, the base doping, and the bulk lifetime on the output characteristics like the light current-voltage curves and the internal quantum efficiency of the IBC solar cell, were investigated. The light absorption was determined by adjusting the antireflection coating and the Al thickness. The FSF must be thin and have a low doping concentration for high-efficiency IBC cells. If the conversion efficiency is to be improved, a thick emitter and a high doping concentration are needed. Because of the low resistivity of the Si substrate, the series resistance was reduced, but recombination was increased. With a high-resistivity Si substrate, the opposite trends were observed. By counter-balancing the series resistance and the recombination, we determined by simulation that the optimized resistivity for the IBC cells was 1 Ω·cm. Because all metal electrodes in the IBC cells are located on the back side, a higher minority carrier lifetime showed a higher efficiency. After the various parameters had been optimized, texturing and surface recombination were added into the simulation. The simulated IBC cells showed a short-circuit current density of 42.89 mA/cm2, an open-circuit voltage of 714.8 mV, a fill factor of 84.04%, and a conversion efficiency of 25.77%.

  18. Electrical DNA biosensor using aluminium interdigitated electrode for E.Coli O157:H7 detection

    Science.gov (United States)

    Natasha, N. Z.; Rajapaksha, R. D. A. A.; Uda, M. N. A.; Hashim, U.

    2017-09-01

    Escherichia Coli (E.Coli) O157:H7 is the one of the most dangerous foodborne pathogens based diseases that presence in our daily life that causes illness and death increase every year. Aluminum Interdigitated Electrode (Al IDE) biosensor was introduced to detect E.Coli O157:H7 in earlier stage. In this paper we investigated ssDNA of E.Coli O157:H7 bacteria detection through electrical behavior of Al IDE sensor. The physical properties of Al IDE biosensor has been characterized using Low Power Microscope (LPM), High Power Microscope (HPM), Scanning Electron Microscope (SEM) and 3D Nano Profiler. The bare Al IDE was electrical characterized by using I-V measurement. The surface modification was accomplished by salinization using APTES and immobilization using Carboxylic Probe E.Coli which was the first step in preparing Al IDE biosensor. Geared up prepared biosensor was hybridized with complementary, non-complementary and single based mismatch ssDNA to confirmed specificity detection of E Coli O157:H7 ssDNA target. The Current - Voltage was performed for each step such as bare Al IDE, surface modification, immobilization and hybridization. Sensitivity measurement was accomplished using different concentration of complementary ssDNA target from 1 fM - 10 µM. Selectivity measurements was achieved using same concentration which was 10 µM concentration for complement, non-complement and mismatch E.Coli O157:H7 ssDNA target. It's totally proved that the Al IDE able to detect specific and small current down to Femtomolar concentration.

  19. Retinoblastoma-binding Protein 1 Has an Interdigitated Double Tudor Domain with DNA Binding Activity*

    Science.gov (United States)

    Gong, Weibin; Wang, Jinfeng; Perrett, Sarah; Feng, Yingang

    2014-01-01

    Retinoblastoma-binding protein 1 (RBBP1) is a tumor and leukemia suppressor that binds both methylated histone tails and DNA. Our previous studies indicated that RBBP1 possesses a Tudor domain, which cannot bind histone marks. In order to clarify the function of the Tudor domain, the solution structure of the RBBP1 Tudor domain was determined by NMR and is presented here. Although the proteins are unrelated, the RBBP1 Tudor domain forms an interdigitated double Tudor structure similar to the Tudor domain of JMJD2A, which is an epigenetic mark reader. This indicates the functional diversity of Tudor domains. The RBBP1 Tudor domain structure has a significant area of positively charged surface, which reveals a capability of the RBBP1 Tudor domain to bind nucleic acids. NMR titration and isothermal titration calorimetry experiments indicate that the RBBP1 Tudor domain binds both double- and single-stranded DNA with an affinity of 10–100 μm; no apparent DNA sequence specificity was detected. The DNA binding mode and key interaction residues were analyzed in detail based on a model structure of the Tudor domain-dsDNA complex, built by HADDOCK docking using the NMR data. Electrostatic interactions mediate the binding of the Tudor domain with DNA, which is consistent with NMR experiments performed at high salt concentration. The DNA-binding residues are conserved in Tudor domains of the RBBP1 protein family, resulting in conservation of the DNA-binding function in the RBBP1 Tudor domains. Our results provide further insights into the structure and function of RBBP1. PMID:24379399

  20. Retinoblastoma-binding protein 1 has an interdigitated double Tudor domain with DNA binding activity.

    Science.gov (United States)

    Gong, Weibin; Wang, Jinfeng; Perrett, Sarah; Feng, Yingang

    2014-02-21

    Retinoblastoma-binding protein 1 (RBBP1) is a tumor and leukemia suppressor that binds both methylated histone tails and DNA. Our previous studies indicated that RBBP1 possesses a Tudor domain, which cannot bind histone marks. In order to clarify the function of the Tudor domain, the solution structure of the RBBP1 Tudor domain was determined by NMR and is presented here. Although the proteins are unrelated, the RBBP1 Tudor domain forms an interdigitated double Tudor structure similar to the Tudor domain of JMJD2A, which is an epigenetic mark reader. This indicates the functional diversity of Tudor domains. The RBBP1 Tudor domain structure has a significant area of positively charged surface, which reveals a capability of the RBBP1 Tudor domain to bind nucleic acids. NMR titration and isothermal titration calorimetry experiments indicate that the RBBP1 Tudor domain binds both double- and single-stranded DNA with an affinity of 10-100 μM; no apparent DNA sequence specificity was detected. The DNA binding mode and key interaction residues were analyzed in detail based on a model structure of the Tudor domain-dsDNA complex, built by HADDOCK docking using the NMR data. Electrostatic interactions mediate the binding of the Tudor domain with DNA, which is consistent with NMR experiments performed at high salt concentration. The DNA-binding residues are conserved in Tudor domains of the RBBP1 protein family, resulting in conservation of the DNA-binding function in the RBBP1 Tudor domains. Our results provide further insights into the structure and function of RBBP1.

  1. Effect of BST film thickness on the performance of tunable interdigital capacitors grown by MBE

    Science.gov (United States)

    Meyers, Cedric J. G.; Freeze, Christopher R.; Stemmer, Susanne; York, Robert A.

    2017-12-01

    Voltage-tunable, interdigital capacitors (IDCs) were fabricated on Ba0.29Sr0.71TiO3 grown by hybrid molecular beam epitaxy (MBE). In this growth technique, we utilize the metal-organic precursor titanium tetraisopropoxide rather than solid-source Ti as with conventional MBE. Two samples of varying BaxSr(1-x)TiO3 (BST) thicknesses were fabricated and analyzed. High-quality, epitaxial Pt electrodes were deposited by sputtering from a high-purity Pt target at 825 °C. The Pt electrodes were patterned and etched by argon ion milling, passivated with reactively sputtered SiO2, and then metallized with lift-off Ti/Au. The fabricated devices consisted of two-port IDCs embedded in ground-signal-ground, coplanar waveguide (CPW) transmission lines to enable radio-frequency (RF) probing. The sample included open and thru de-embedding structures to remove pad and CPW parasitic impedances. Two-port RF scattering (S) parameters were measured from 100 MHz to 40 GHz while DC bias was stepped from 0 V to 100 V. The IDCs exhibit a high zero-bias radio-frequency (RF) quality factor (Q) approaching 200 at 1 GHz and better than 2.3:1 capacitance tuning for the 300-nm-thick sample. Differences in the Q(V) and C(V) response with varying thicknesses indicate that unknown higher order material phenomena are contributing to the loss and tuning characteristics of the material.

  2. Low pH induces an interdigitated gel to bilayer gel phase transition in dihexadecylphosphatidylcholine membrane.

    Science.gov (United States)

    Furuike, S; Levadny, V G; Li, S J; Yamazaki, M

    1999-10-01

    We have investigated the influence of pH on the structures and phase behaviors of multilamellar vesicles of the ether-linked dihexadecylphosphatidylcholine (DHPC-MLV). This phospholipid is known to be in the interdigitated gel (L(beta)I) phase in excess water at 20 degrees C at neutral pH. The results of X-ray diffraction experiments indicate that a phase transition from L(beta)I phase to the bilayer gel phase occurred in DHPC-MLV in 0.5 M KCl around pH 3.9 with a decrease in pH, and that at low pH values, less than pH 2.2, DHPC-MLVs were in L(beta') phase. The results of fluorescence and light scattering method indicate that the gel to liquid-crystalline phase transition temperature (T(m)) of DHPC-MLV increased with a decrease in pH. On the basis of a thermodynamic analysis, we conclude that the main mechanism of the low-pH induced L(beta)I to bilayer gel phase transition in DHPC-MLV and the increase in its T(m) is connected with the decrease in the repulsive interaction between the headgroups of these phospholipids. As pH decreases, the phosphate groups of the headgroups begin to be protonated, and as a result, the apparent positive surface charges appear. However, surface dipoles decrease and the interaction free energy of the hydrophilic segments with water increases. The latter effect dominates the pure electrostatic repulsion between the charged headgroups, and thereby, the total repulsive interaction in the interface decreases.

  3. Response of Solid He-4 to External Stress: Interdigital Capacitor Solid Level Detector and Optical Interferometer

    Science.gov (United States)

    Fay, J.; Wada, Y.; Masutomi, R.; Elkholy, T.; Kojima, H.

    2003-01-01

    Two experiments are being conducted to observe the liquid/solid interface of He-4 near 1 K. Interesting instabilities are expected to occur when the solid is non-hydrostatically stressed. (1)A compact interdigital capacitor is used as a level detector to observe solid He-4 to which stresses are applied externally. The capacitor consists of 38 interlaced 50 m wide and 3.8 mm long gold films separated by 50 m and deposited onto a 5 mm by 5 mm sapphire substrate. The capacitor is placed on one flat end wall of a cylindrical chamber (xx mm diameter and xx mm long). The solid is grown to a known height and a stress is applied by a tubular PZT along the cylindrical axis. The observed small change in height of the solid at the wall is linearly proportional to the applied stress. The solid height decreases under compressive stress but does not change under tensile stress. The response of the solid on compressive stress is consistent with the expected quadratic dependence on strain. (2)Interferometric techniques are being developed for observing the solid He-4 surface profile. A laser light source is brought into the low temperature region via single mode optical fiber. The interference pattern is transmitted back out of the low temperature apparatus via optical fiber bundle. The solid He-4 growth chamber will be equipped with two PZT's such that stress can be applied from orthogonal directions. Orthogonally applied stress is expected to induce surface instability with island-like deformation on a grid pattern. Apparatus design and progress of its construction are described.

  4. AC electrokinetic drug delivery in dentistry using an interdigitated electrode assembly powered by inductive coupling.

    Science.gov (United States)

    Ivanoff, Chris S; Wu, Jie Jayne; Mirzajani, Hadi; Cheng, Cheng; Yuan, Quan; Kevorkyan, Stepan; Gaydarova, Radostina; Tomlekova, Desislava

    2016-10-01

    AC electrokinetics (ACEK) has been shown to deliver certain drugs into human teeth more effectively than diffusion. However, using electrical wires to power intraoral ACEK devices poses risks to patients. The study demonstrates a novel interdigitated electrode arrays (IDE) assembly powered by inductive coupling to induce ACEK effects at appropriate frequencies to motivate drugs wirelessly. A signal generator produces the modulating signal, which multiplies with the carrier signal to produce the amplitude modulated (AM) signal. The AM signal goes through the inductive link to appear on the secondary coil, then rectified and filtered to dispose of its carrier signal, and the positive half of the modulating signal appears on the load. After characterizing the device, the device is validated under light microscopy by motivating carboxylate-modified microspheres, tetracycline, acetaminophen, benzocaine, lidocaine and carbamide peroxide particles with induced ACEK effects. The assembly is finally tested in a common dental bleaching application. After applying 35 % carbamide peroxide to human teeth topically or with the IDE at 1200 Hz, 5 Vpp for 20 min, spectrophotometric analysis showed that compared to diffusion, the IDE enhanced whitening in specular optic and specular optic excluded modes by 215 % and 194 % respectively. Carbamide peroxide absorbance by the ACEK group was two times greater than diffusion as measured by colorimetric oxidation-reduction and UV-Vis spectroscopy at 550 nm. The device motivates drugs of variable molecular weight and structure wirelessly. Wireless transport of drugs to intraoral targets under ACEK effects may potentially improve the efficacy and safety of drug delivery in dentistry.

  5. Interdigitated back contact solar cells with polycrystalline silicon on oxide passivating contacts for both polarities

    Science.gov (United States)

    Haase, Felix; Kiefer, Fabian; Schäfer, Sören; Kruse, Christian; Krügener, Jan; Brendel, Rolf; Peibst, Robby

    2017-08-01

    We demonstrate an independently confirmed 25.0%-efficient interdigitated back contact silicon solar cell with passivating polycrystalline silicon (poly-Si) on oxide (POLO) contacts that enable a high open circuit voltage of 723 mV. We use n-type POLO contacts with a measured saturation current density of J 0n = 4 fA cm-2 and p-type POLO contacts with J 0p = 10 fA cm-2. The textured front side and the gaps between the POLO contacts on the rear are passivated by aluminum oxide (AlO x ) with J 0AlO x = 6 fA cm-2 as measured after deposition. We analyze the recombination characteristics of our solar cells at different process steps using spatially resolved injection-dependent carrier lifetimes measured by infrared lifetime mapping. The implied pseudo-efficiency of the unmasked cell, i.e., cell and perimeter region are illuminated during measurement, is 26.2% before contact opening, 26.0% after contact opening and 25.7% for the finished cell. This reduction is due to an increase in the saturation current density of the AlO x passivation during chemical etching of the contact openings and of the rear side metallization. The difference between the implied pseudo-efficiency and the actual efficiency of 25.0% as determined by designated-area light current-voltage (I-V) measurements is due to series resistance and diffusion of excess carriers into the non-illuminated perimeter region.

  6. A 3D Faraday Shield for Interdigitated Dielectrometry Sensors and Its Effect on Capacitance.

    Science.gov (United States)

    Risos, Alex; Long, Nicholas; Hunze, Arvid; Gouws, Gideon

    2016-12-31

    Interdigitated dielectrometry sensors (IDS) are capacitive sensors investigated to precisely measure the relative permittivity ( ϵ r ) of insulating liquids. Such liquids used in the power industry exhibit a change in ϵ r as they degrade. The IDS ability to measure ϵ r in-situ can potentially reduce maintenance, increase grid stability and improve safety. Noise from external electric field sources is a prominent issue with IDS. This paper investigates the novelty of applying a Faraday cage onto an IDS as a 3D shield to reduce this noise. This alters the spatially distributed electric field of an IDS affecting its sensing properties. Therefore, dependency of the sensor's signal with the distance to a shield above the IDS electrodes has been investigated experimentally and theoretically via a Green's function calculation and FEM. A criteria of the shield's distance s = s 0 has been defined as the distance which gives a capacitance for the IDS equal to 1 - e - 2 = 86.5 % of its unshielded value. Theoretical calculations using a simplified geometry gave a constant value for s 0 / λ = 1.65, where λ is the IDS wavelength. In the experiment, values for s 0 were found to be lower than predicted as from theory and the ratio s 0 / λ variable. This was analyzed in detail and it was found to be resulting from the specific spatial structure of the IDS. A subsequent measurement of a common insulating liquid with a nearby noise source demonstrates a considerable reduction in the standard deviation of the relative permittivity from σ unshielded = ± 9.5% to σ shielded = ± 0.6%. The presented findings enhance our understanding of IDS in respect to the influence of a Faraday shield on the capacitance, parasitic capacitances of the IDS and external noise impact on the measurement of ϵ r .

  7. Alternate Tunings for the Linac Coherent Light Source Photoinjector

    CERN Document Server

    Limborg-Deprey, Cecile

    2005-01-01

    The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10 ps long electron bunches of 1nC with a normalized transverse emittance of less than 1 mm.mrad for 80% of the slices constituting the core of the bunch at 135 MeV. Tolerances and regulation requirements are tight for this tuning. The main contribution to emittance is the "cathode emittance which counts for 0.72 mm.mrad for the nominal tuning. As the "cathode emittance" scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2nC, we believe we can achieve an emittance closer to 0.4 mm.mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the nominal one. In this paper, we also discuss how emittance could be further reduced by using the appropriate laser pulse shaping.

  8. IOT RF Power Sources for Pulsed and CW Linacs

    CERN Document Server

    Bohlen, H P

    2004-01-01

    For many years, klystrons have been the preferred RF power amplifiers for both pulsed and CW linacs at UHF and higher frequencies. Their properties have earned them that position. But in recent years in UHF terrestrial television transmitters the earlier predominant klystron has been replaced the Inductive Output Tube (IOT) because the IOT provides higher efficiency and, due to its excellent linearity, can handle the simultaneous amplification of both the vision and the sound signal. Its robustness and life expectancy equals that of a klystron, and it more than compensates its lower gain by a lower price and a smaller size. For linac operation, derivates of UHF TV IOTs, capable of up to 80 kW CW output power, are already available and operating. In L-Band, they are presently joined by recently developed 15 to 30 kW CW IOTs. HOM-IOTs are expected to extend the CW range in UHF to 1 MW and beyond. Pulsed operation of an IOT can be achieved without a high-voltage modulator. Since the beam current is grid-controll...

  9. Superconducting RF Linac Technology for ERL Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Tennant, Chris

    2005-08-01

    Energy Recovering Linacs (ERLs) offer an attractive alternative as drivers for light sources as they combine the desirable characteristics of both storage rings (high efficiency) and linear accelerators (superior beam quality). Using superconducting RF technology allows ERLs to operate more efficiently because of the inherent characteristics of SRF linacs, namely that they are high gradient-low impedance structures and their ability to operate in the long pulse or CW regime. We present an overview of the physics challenges encountered in the design and operation of ERL based light sources with particular emphasis on those issues related to SRF technology. These challenges include maximizing a cavity's Qo to increase cryogenic efficiency, maintaining control of the cavity field in the presence of the highest feasible loaded Q and providing adequate damping of the higher-order modes (HOMs). If not sufficiently damped, dipole HOMs can drive the multipass beam breakup (BBU) instability which ERLs are particularly susceptible to. Another challenge involves efficiently extracting the potentially large amounts of HOM power that are generated when a bunch traverses the SRF cavities and which may extend over a high range of frequencies. We present experimental data from the Jefferson Lab FEL Upgrade, a 10 mA ERL light source presently in operation, aimed at addressing some of these issues. We conclude with an outlook towards the future of ERL based light sources.

  10. First Full Beam Loading Operation with the CTF3 Linac

    CERN Multimedia

    Corsini, R; Bienvenu, G; Braun, H; Carron, G; Ferrari, A; Forstner, O; Garvey, Terence; Geschonke, Günther; Groening, L; Jensen, E; Koontz, R; Lefèvre, T; Miller, R; Rinolfi, Louis; Roux, R; Ruth, Ronald D; Schulte, Daniel; Tecker, F A; Thorndahl, L; Yeremian, A D

    2004-01-01

    The aim of the CLIC (Compact Linear Collider) Study is to investigate the feasibility of a high luminosity, multi-TeV linear e+e- collider. CLIC is based on a two-beam method, in which a high current drive beam is decelerated to produce 30 GHz RF power needed for high-gradient acceleration of the main beam running parallel to it. To demonstrate the outstanding feasibility issues of the scheme a new CLIC Test Facility, CTF3, is being constructed at CERN by an international collaboration. In its final configuration CTF3 will consist of a 150 MeV drive beam linac followed by a 42 m long delay loop and an 84 m combiner ring. The installation will include a 30 GHz high power test stand, a representative CLIC module and a test decelerator. The first part of the linac was installed and commissioned with beam in 2003. The first issue addressed was the generation and acceleration of a high-current drive beam in the "full beam loading" condition where RF power is converted into beam power with an efficiency of more tha...

  11. Status of the Superconducting Proton Linac (SPL) Cryo-Module

    CERN Document Server

    Parma, V; Capatina, O; Chambrillon, J; Montesinos, E; Schirm, K; Vande Craen, A; Vandoni, G; Van Weelderen, R

    2014-01-01

    The Superconducting Proton Linac (SPL) is an R&D effort conducted by CERN in partnership with other international laboratories, aimed at developing key technologies for the construction of a multi-megawatt proton linac based on state-of-the-art SRF technology. Such an accelerator could serve as a driver in new physics facilities for neutrinos and/or radioactive ion beams [1]. Amongst the main objectives of this effort, are the development of 704 MHz bulk niobium beta=1 elliptical cavities (operating at 2 K and providing an accelerating gradient of 25 MV/m) and the test of a string of cavities integrated in a machine-type cryo-module. In an initial phase, only four out of the eight cavities of the SPL cryo-module will be tested in a half-length cryo-module developed for this purpose, which nonetheless preserves the main features of the full size module. This paper presents the final design of the cryo-module and the status of the construction of the main cryostat parts. Preliminary plans for the assembly a...

  12. Energy-Spread-Feedback System for the KEKB Injector Linac

    CERN Document Server

    Satoh, Masanori; Suwada, Tsuyoshi

    2005-01-01

    New energy-spread feedback system using nondestructive energy-spread monitors have been developed in order to control and stabilize the energy spreads of single-bunch electron and positron beams in the KEKB injector linac. The well-controlled feedback systems of the injector linac are successfully working in dairy operation not only for keeping the injection rate higher along with the beam-orbit and energy feedback systems but also for reducing a background level to the high-energy B-factory experiment. The energy spreads of the injection beams are well stabilized within 0.2%, 0.5% and 0.3% for the electron beam, the positron beam, and the high-current primary electron beam for positron production, respectively, through the energy-spread feedback system under the nominal operation condition. In this paper, we will report in detail the energy-spread feedback system using the nondestructive energy-spread monitors with multi-strip-line electrodes and their performance in the KEKB operation.

  13. Linac4 45 keV Proton Beam Measurements

    CERN Document Server

    Bellodi, G; Hein, L M; Lallement, J-B; Lombardi, A M; Midttun, O; Scrivens, R; Posocco, P A

    2013-01-01

    Linac4 is a 160 MeV normal-conducting H- linear accelerator, which will replace the 50 MeV proton Linac2 as injector for the CERN proton complex. Commissioning of the low energy part - comprising the H - source, a 45 keV Low Energy Beam Transport line (LEBT), a 3 MeV Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) - will start in fall 2012 on a dedicated test stand installation. In preparation to this, preliminary measurements were taken using a 45 keV proton source and a temporary LEBT setup, with the aim of characterising the output beam by comparison with the predictions of simulations. At the same time this allowed a first verification of the functionalities of diagnostics instrumentation and acquisition software tools. Measurements of beam profile, emittance and intensity were taken in three different setups: right after the source, after the first and after the second LEBT solenoids respectively. Particle distributions were reconstructed from emittance scan...

  14. Dosimetric Algorithm to Reproduce Isodose Curves Obtained from a LINAC

    Directory of Open Access Journals (Sweden)

    Julio Cesar Estrada Espinosa

    2014-01-01

    Full Text Available In this work isodose curves are obtained by the use of a new dosimetric algorithm using numerical data from percentage depth dose (PDD and the maximum absorbed dose profile, calculated by Monte Carlo in a 18 MV LINAC. The software allows reproducing the absorbed dose percentage in the whole irradiated volume quickly and with a good approximation. To validate results an 18 MV LINAC with a whole geometry and a water phantom were constructed. On this construction, the distinct simulations were processed by the MCNPX code and then obtained the PDD and profiles for the whole depths of the radiation beam. The results data were used by the code to produce the dose percentages in any point of the irradiated volume. The absorbed dose for any voxel’s size was also reproduced at any point of the irradiated volume, even when the voxels are considered to be of a pixel’s size. The dosimetric algorithm is able to reproduce the absorbed dose induced by a radiation beam over a water phantom, considering PDD and profiles, whose maximum percent value is in the build-up region. Calculation time for the algorithm is only a few seconds, compared with the days taken when it is carried out by Monte Carlo.

  15. Ultrashort Optical Pulses in the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Bharadwaj, V.

    2005-01-31

    The Linac Coherent Light Source (LCLS) project at the Stanford Linear Accelerator Center (SLAC) will produce intense, coherent 0.15 nm x-rays, with an expected peak brightness many orders of magnitude greater than existing x-ray sources and energy density as high as 4 x 10{sup 25} watts/cm{sup 2}. These x-rays are produced by a single pass of a 15 GeV electron beam through a long undulator. The 15 GeV electron beam is generated using the last one third of the existing SLAC linac. This paper describes how to extend the present design of the LCLS to generate even shorter x-ray pulses than the nominal 255 femtoseconds FWHM. The goal of this study is to obtain pulse lengths as short as 50 femtoseconds. The scientific need for the shorter bunches is outlined, and electron and x-ray pulse compression options are reviewed. The analysis concludes that there are paths, albeit difficult, to obtaining shorter bunches and that the present LCLS design has the flexibility and range to test these paths.

  16. Dosimetric algorithm to reproduce isodose curves obtained from a LINAC.

    Science.gov (United States)

    Estrada Espinosa, Julio Cesar; Martínez Ovalle, Segundo Agustín; Pereira Benavides, Cinthia Kotzian

    2014-01-01

    In this work isodose curves are obtained by the use of a new dosimetric algorithm using numerical data from percentage depth dose (PDD) and the maximum absorbed dose profile, calculated by Monte Carlo in a 18 MV LINAC. The software allows reproducing the absorbed dose percentage in the whole irradiated volume quickly and with a good approximation. To validate results an 18 MV LINAC with a whole geometry and a water phantom were constructed. On this construction, the distinct simulations were processed by the MCNPX code and then obtained the PDD and profiles for the whole depths of the radiation beam. The results data were used by the code to produce the dose percentages in any point of the irradiated volume. The absorbed dose for any voxel's size was also reproduced at any point of the irradiated volume, even when the voxels are considered to be of a pixel's size. The dosimetric algorithm is able to reproduce the absorbed dose induced by a radiation beam over a water phantom, considering PDD and profiles, whose maximum percent value is in the build-up region. Calculation time for the algorithm is only a few seconds, compared with the days taken when it is carried out by Monte Carlo.

  17. Linac Coherent Light Source (LCLS) design study report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 {angstrom}. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues.

  18. X-ray detectors at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella, E-mail: carini@slac.stanford.edu; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; Herrmann, Sven; Kenney, Chris; Markovic, Bojan; Nishimura, Kurtis; Osier, Shawn; Pines, Jack; Reese, Benjamin; Segal, Julie; Tomada, Astrid; Weaver, Matt [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-21

    This paper offers an overview of area detectors developed for use at the Linac Coherent Light Source (LCLS) with particular emphasis on their impact on science. The experimental needs leading to the development of second-generation cameras for LCLS are discussed and the new detector prototypes are presented. Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

  19. Beam tests on a proton linac booster for hadron therapy

    CERN Document Server

    De Martinis, C; Berra, P; Birattari, C; Calabretta, L; Crandall, K; Giove, D; Masullo, M R; Mauri, M; Rosso, E; Rovelli, A; Serafini, L; Szeless, Balázs; Toet, D Z; Vaccaro, Vittorio G; Weiss, M; Zennaro, R

    2002-01-01

    LIBO is a 3 GHz modular side-coupled proton linac booster designed to deliver beam energies up to 200 MeV, as required for the therapy of deep seated tumours. The injected beam of 50 to 70 MeV is produced by a cyclotron like those in several hospitals and research institutes. A full-scale prototype of the first module with an input/output energy of 62/74 MeV, respectively, was designed and built in 1999 and 2000. Full power RF tests were carried out successfully at CERN using a test facility at LIL at the end of the year 2000. In order to prove the feasibility of the acceleration process, an experimental setup with this module was installed at the INFN Laboratorio Nazionale del Sud (LNS) in Catania during 2001. The superconducting cyclotron provided the 62 MeV test beam. A compact solid-state RF modulator with a 4 MW klystron, made available by IBA-Scanditronix, was put into operation to power the linac. In this paper the main features of the accelerator are reviewed and the experimental results obtained duri...

  20. Spiral 2 Cryogenic System for The Superconducting LINAC

    Science.gov (United States)

    Ghribi, A.; Bernaudin, P.-E.; Bert, Y.; Commeaux, C.; Houeto, M.; Lescalié, G.

    2017-02-01

    SPIRAL 21 is a rare isotope accelerator dedicated to the production of high intensity beams (E = 40 MeV, I = 5 mA). The driver is a linear accelerator (LINAC) that uses bulk Niobium made quarter wave RF cavities. 19 cryomodules inclose one or two cavities respectively for the low and the high energy sections. To supply the 1300 W at 4.2 K required to cool down the LINAC, a cryogenic system has been set up. The heart of the latter is a 3 turbines geared HELIAL®LF (ALAT2) cold box that delivers both the liquid helium for the cavities and the 60 K Helium gaz for the thermal screens. 19 valve-boxes insure cryogenic fluid distribution and management. Key issues like cool down speed or cavity RF frequency stability are closely linked to the cryogenic system management. To overcome these issues, modelling and simulation efforts are being undertaken prior to the first cool down trials. In this paper, we present a status update of the Spiral 2 cryogenic system and the cool down strategy considered for its commissioning.

  1. Spatial and temporal beam profile monitor with nanosecond resolution for CERN's Linac4 and Superconducting Proton Linac

    CERN Document Server

    Hori, M

    2008-01-01

    The Linac4, now being developed at CERN, will provide 160-MeV H- beams of high intensity . Before this beam can be injected into the CERN Proton Synchrotron Booster or future Superconducting Proton Linac for further acceleration, some sequences of 500-ps-long micro-bunches must be removed from it, using a beam chopper. These bunches, if left in the beam, would fall outside the longitudinal acceptance of the accelerators and make them radioactive. We developed a monitor to measure the time structure and spatial profile of this chopped beam, with respective resolutions and . Its large active area and dynamic range also allows investigations of beam halos. The ion beam first struck a carbon foil, and secondary electrons emerging from the foil were accelerated by a series of parallel grid electrodes. These electrons struck a phosphor screen, and the resulting image of the scintillation light was guided to a thermoelectrically cooled, charge-coupled device camera. The time resolution was attained by applying high-...

  2. Radiological safety around a Linac of 18 MV; Seguridad radiologica alrededor de un LINAC de 18 MV

    Energy Technology Data Exchange (ETDEWEB)

    Ceron R, P.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Calz. Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Sanchez, A. [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, Edif. 9, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico); Vega C, H. R., E-mail: victceronr@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 09868 Zacatecas (Mexico)

    2014-10-15

    There are now several neutron detection systems, such as proportional counters based on BF{sub 3}, He{sub 3} and Bonner sphere spectrometers. However, the cost and complexity of the implementation of such systems makes them inaccessible for dosimetry purposes in radiotherapy rooms (Rt) and other facilities with this type of radiation fields. For these reasons the use of a neutron detection system is proposed composed by a paraffin moderator media forming an array 4π (spheres) and several pairs of thermoluminescent dosimeters TLD 600/TLD 700 inside, in order to make useful measurements for radiation protection around high-energy lineal accelerators (Linacs). In the first part of this work the system response when irradiated with a source of Pu Be and their corresponding calibration factor is displayed. In the second part are presented the ambient dose equivalent (H(10)) due to neutrons at various points of a living of Rt with a Linac of 18 MV, which are in the order mSv/Gy by X-ray treatment. The measurements made are similar to those taken in the memories of the accelerator and in previous work for this type of facility. (Author)

  3. CERN Linac4 Beam Dynamics Studies and Commissioning up to 12 MeV

    CERN Document Server

    Yildiz, Veli; Dimov, Veliko Atanasov; Ozcan, Erkcan; Arik, Metin

    Linac4 is a normal conducting, 160 MeV H ions accelerator that is being constructed within the scope of the LHC Injectors Upgrade project. Linac4 will be connected to the Proton Synchrotron Booster during the next long LHC shutdown and it will replace the current 50 MeV proton linac, Linac2. Linac4 is being commissioned progressively with the installation of the accelerating structures into the Linac4 tunnel. Movable diagnostic benches, with various instruments, are used at each step to allow the detailed characterization of operational parameters that will play a key role in the overall future performance. The rst three stages of the commissioning, up to 12 MeV beam energy, were completed by the end of 2014 with a temporary version of the ion source. Using the permanent diagnostic instruments and a movable diagnostic bench, the Low Energy Beam Transport (LEBT) at 45 keV, the Radio Frequency Quadrupole (RFQ) and Medium Energy Beam Transport (MEBT) at 3 MeV, as well as the rst tank of the Drift Tube Linac ...

  4. Interdigitating dendritic cell sarcoma presenting in the kidney combined with retroperitoneal leiomyosarcoma: A case report and literature review.

    Science.gov (United States)

    Zhang, Jiexiu; Liu, Bianjiang; Song, Ninghong; Hua, Lixin; Wang, Zengjun; Yin, Changjun

    2014-02-01

    Interdigitating dendritic cell sarcoma (IDCS) and retroperitoneal leiomyosarcoma are rare tumors. The optimal diagnosis, treatment and prognosis remain unknown. The current case report presents a 46-year-old male who exhibited with a left renal mass combined with a periprostatic mass. The patient underwent surgery twice, respectively for the resection of the two masses. The postoperative pathological examination confirmed the diagnosis of IDCS presenting in the kidney and retroperitoneal leiomyosarcoma in the pelvis. To the best of our knowledge, it is the first report of IDCS in the kidney and of the combined appearance of IDCS and retroperitoneal leiomyosarcoma in the same patient.

  5. Interdigital infections caused by non-dermatophytic fungi Infecciones interdigitales por hongos no dermatofíticos

    OpenAIRE

    Herta Vélez

    1990-01-01

    Between 1983 and 1989 twelve cases of interdigital lesions of the feet due to non-dermatophytic fungi (NDF) were diagnosed at the Medical Mycology Laboratory, University of Antioquia, School of Medicine, Medellín,

    Colombia; the agents respons...

  6. Pulsed-focusing recirculating linacs for muon acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland [Muons, Inc., Batavia, IL (United States)

    2014-12-31

    Since the muon has a short lifetime, fast acceleration is essential for high-energy applications such as muon colliders, Higgs factories, or neutrino factories. The best one can do is to make a linear accelerator with the highest possible accelerating gradient to make the accelerating time as short as possible. However, the cost of such a single linear accelerator is prohibitively large due to expensive power sources, cavities, tunnels, and related infrastructure. As was demonstrated in the Thomas Jefferson Accelerator Facility (Jefferson Lab) Continuous Electron Beam Accelerator Facility (CEBAF), an elegant solution to reduce cost is to use magnetic return arcs to recirculate the beam through the accelerating RF cavities many times, where they gain energy on each pass. In such a Recirculating Linear Accelerator (RLA), the magnetic focusing strength diminishes as the beam energy increases in a conventional linac that has constant strength quadrupoles. After some number of passes the focusing strength is insufficient to keep the beam from going unstable and being lost. In this project, the use of fast pulsed quadrupoles in the linac sections was considered for stronger focusing as a function of time to allow more successive passes of a muon beam in a recirculating linear accelerator. In one simulation, it was shown that the number of passes could be increased from 8 to 12 using pulsed magnet designs that have been developed and tested. This could reduce the cost of linac sections of a muon RLA by 8/12, where more improvement is still possible. The expense of a greater number of passes and corresponding number of return arcs was also addressed in this project by exploring the use of ramped or FFAG-style magnets in the return arcs. A better solution, invented in this project, is to use combined-function dipole-quadrupole magnets to simultaneously transport two beams of different energies through one magnet string to reduce costs of return arcs by almost a factor of

  7. Estudo clínico com o uso do itraconazol em tinha crural, tinha do corpo e tinha do pé interdigital Clinical trial with itraconazole in the treatment of Tinea cruris, Tinea corporis and tinea pedis interdigital

    Directory of Open Access Journals (Sweden)

    Clarisse Zaitz

    1990-08-01

    Full Text Available Os autores estudaram 31 pacientes portadores de tinhas crural, do corpo e do pé interdigital, tratados com 100 mg de itraconazol, administrados junto com o almoço, durante 15 dias. Foram realizadas 3 avaliações clínicas e micológicas: no pré-tratamento, no final do tratamento e 2 semanas após o tratamento. O itraconazol mostrou-se eficaz para o tratamento das dermatofitoses estudadas, na dose empregada, com 100% de cura micológica. Em relação a evolução clínica, houve diminuição estatística significante (teste de Friedman - p The authors studied 31 patients with Tinea cruris, corporis or pedis interdigital. The patients were treated with 100 mg of itraconazole, once a day, during the lunch, for 15 days. Mycological and clinical evaluations were performed at the pre-treatment, by the end of treatment and 2 weeks after finishing the treatment. The results showed that itraconazole is effective for the treatment of dermatophytosis, at the studied posology. with 100% of mycological cure. Clinical evaluation showed a significant reduction (Friedman test - p < 0.001 of signs and symptoms. No side-effect was registered.

  8. Linac4 RFQ assembly is carried out before installation in Building 152

    CERN Multimedia

    Anna Pantelia

    2012-01-01

    This series of pictures documents the assembly phase of the Linac4 RFQ (Radio Frequency Quadrupole), performed at the end of July 2012. The Linac4 RFQ is made of 3 modules, 1 meter each, assembled together to accelerate the H- or proton beam from the ion source extraction at 45 kV to the energy of 3 MeV. The RFQ is the first of the Linac4 accelerating structures, which will increase to 160 MeV the beam injection energy into the PS Booster as from the end of LS2.

  9. Simultaneous optimization of the cavity heat load and trip rates in linacs using a genetic algorithm

    Directory of Open Access Journals (Sweden)

    Balša Terzić

    2014-10-01

    Full Text Available In this paper, a genetic algorithm-based optimization is used to simultaneously minimize two competing objectives guiding the operation of the Jefferson Lab’s Continuous Electron Beam Accelerator Facility linacs: cavity heat load and radio frequency cavity trip rates. The results represent a significant improvement to the standard linac energy management tool and thereby could lead to a more efficient Continuous Electron Beam Accelerator Facility configuration. This study also serves as a proof of principle of how a genetic algorithm can be used for optimizing other linac-based machines.

  10. Status of the Argonne superconducting-linac heavy-ion energy booster

    Energy Technology Data Exchange (ETDEWEB)

    Aron, J.; Benaroya, R.; Bollinger, L.M.; Clifft, B.E.; Henning, W.; Johnson, K.W.; Nixon, J.M.; Markovich, P.; Shepard, K.W.

    1979-01-01

    A superconducting linac is being constructed to provide an energy booster for heavy ions from an FN tandem. By late 1980 the linac will consist of 24 independently-phased superconducting resonators, and will provide an effective accelerating potential of more than 25 MV. While the linac is under construction, completed sections are being used to provide useful beam for nuclear physics experiments. In the most recent run with beam (June 1979), an eight resonator array provided an effective accelerating potential of 9.3 MV. Operation of a 12 resonator array is scheduled to begin in October 1979.

  11. Linac Coherent Light Source Undulator RF BPM System

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.; Walters, D.R.; /Argonne; Johnson, R.; Li, Z.; Smith, S.; Straumann, T.; /SLAC

    2007-04-17

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, and prototype test results.

  12. High Power CW Superconducting Linacs for EURISOL and XADS

    CERN Document Server

    Biarrotte, J L

    2004-01-01

    A multi-MW superconducting proton linac is proposed as the baseline solution for the EURISOL and the XADS driver accelerators. In the EURISOL project, which studies the design of the next-generation European ISOL facility, it is used to produce both neutron-deficient and neutron-rich exotic nuclei far from the valley of stability. In the PDS-XADS project, which aims to the demonstration of the feasibility of an ADS system for nuclear waste transmutation, it is used to produce the neutron flux required by the associated sub-critical reactor. In this paper, we report the main results and conclusions reached within these preliminary design studies. A special emphasis is given on the on-going and future R&D to be done to accomplish the demonstration of the full technology.

  13. Overview of the CERN Linac4 beam instrumentation

    CERN Document Server

    Roncarolo, F; Bravin, E; Dehning, B; Duraffourg, M; Gerard, D; Holzer, E B; Lenardon, F; Focker, G; Raich, U; Soby, L; Sordet, M; Tan, J; Tranquille, G; Vuitton, C; Zamantzas, C; Cheymol, B

    2010-01-01

    The CERN LINAC4 will represent the first upgrade of the LHC injection chain, by accelerating H- ions from 45 KeV to 160 MeV for charge-exchange injection into the PS Booster. In order to provide its safe and efficient commissioning and operation, a wide variety of beam diagnostics devices has been designed for installation at convenient locations all over the accelerator length and in the transfer line to the PS Booster. This paper gives an overview of all instrumentation devices, including those to measure beam position, transverse and longitudinal profile, beam current and beam loss. The well advanced status of the system design and the main instrument features are discussed

  14. A 300-nm compact mm-wave linac FEL design

    Energy Technology Data Exchange (ETDEWEB)

    Nassiri, A.; Kustom, R.L.; Kang, Y.W. [Argonne National Lab., IL (United States)

    1995-12-31

    Microfabrication technology offers an alternative method for fabricating precision, miniature-size components suitable for use in accelerator physics and commercial applications. The original R&D work at Argonne, in collaboration with the University of Illinois at Chicago, has produced encouraging results in the area of rf accelerating structure design, optical and x-ray masks production, deep x-ray lithography (LIGA exposures), and precision structural alignments. In this paper we will present a design study for a compact single pass mm-linac FEL to produce short wavelength radiation. This system will consists of a photocathode rf gun operated at 30 GHz, a 50-MeV superconducting constant gradient structure operated at 60 GHz, and a microundulator with 1-mm period. Initial experimental results on a scale model rf gun and microundulator will be presented.

  15. Design study of a medical proton linac for neutron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Machida, S.; Raparia, D.

    1988-08-26

    This paper describes a design study which establishes the physical parameters of the low energy beam transport, radiofrequency quadrupole, and linac, using computer programs available at Fermilab. Beam dynamics studies verify that the desired beam parameters can be achieved. The machine described here meets the aforementioned requirements and can be built using existing technology. Also discussed are other technically feasible options which could be attractive to clinicians, though they would complicate the design of the machine and increase construction costs. One of these options would allow the machine to deliver 2.3 MeV protons to produce epithermal neutrons for treating brain tumors. A second option would provide 15 MeV protons for isotope production. 21 refs., 33 figs.

  16. High Gradient Accelerating Structures for Carbon Therapy Linac

    Energy Technology Data Exchange (ETDEWEB)

    Kutsaev, Sergey; Agustsson, R.; Faillace, L.; Goel, A.; Mustapha, B.; Nassiri, A.; Ostroumov, P.; Plastun, A.; Savin, E.

    2016-05-01

    Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

  17. RF Plasma modeling of the Linac4 H− ion source

    CERN Document Server

    Mattei, S; Hatayama, A; Lettry, J; Kawamura, Y; Yasumoto, M; Schmitzer, C

    2013-01-01

    This study focuses on the modelling of the ICP RF-plasma in the Linac4 H− ion source currently being constructed at CERN. A self-consistent model of the plasma dynamics with the RF electromagnetic field has been developed by a PIC-MCC method. In this paper, the model is applied to the analysis of a low density plasma discharge initiation, with particular interest on the effect of the external magnetic field on the plasma properties, such as wall loss, electron density and electron energy. The use of a multi-cusp magnetic field effectively limits the wall losses, particularly in the radial direction. Preliminary results however indicate that a reduced heating efficiency results in such a configuration. The effect is possibly due to trapping of electrons in the multi-cusp magnetic field, preventing their continuous acceleration in the azimuthal direction.

  18. Fast ferroelectric phase shifters for energy recovery linacs

    Directory of Open Access Journals (Sweden)

    S. Yu Kazakov

    2010-11-01

    Full Text Available Fast phase shifters are described that use a novel barium strontium titanate ceramic that can rapidly change its dielectric constant as an external bias voltage is changed. These phase shifters promise to reduce by ∼10 times the power requirements for the rf source needed to drive an energy recovery linac (ERL. Such phase shifters will be coupled with superconducting radiofrequency cavities so as to tune them to compensate for phase instabilities, whether beam-driven or those caused by microphonics. The most promising design is presented, which was successfully cold tested and demonstrated a switching speed of ∼30  ns for 77 deg, corresponding to <0.5  ns per deg of rf phase. Other crucial issues (losses, phase shift values, etc. are discussed.

  19. Visual verification of linac light and radiation fields coincidence.

    Science.gov (United States)

    Monti, Angelo F; Frigerio, Milena; Frigerio, Giovanna

    2003-01-01

    X-ray and light field alignment evaluation is carried out during linac quality assurance programs. In this paper, we compare the size of the light field measured by a photodiode and by a more traditional visual observation with the size of the x-ray field. The comparison between actual light field size, measured with the photodiode, and light field size measured by human eye allow us to verify the reliability of human eye in the evaluation of this parameter. The visual field is always larger than real light field; however, it agrees better with the x-ray field. It matches the light field if we take into account the 25% (+/- 1%) of the decrement line of the maximum central lightening; however, this method simulates better the actual field employed in radiation treatments.

  20. A medical facility proposal to use the SSC linac

    Science.gov (United States)

    Warren Funk, L.

    1995-05-01

    A consortium organized by the Texas National Research Laboratory Commission (TNRLC) under a Department of Energy (DOE) grant proposes to build and operate a Regional Medical Technology Center (RMTC) to function as a combined medical radioisotope production complex and proton cancer therapy facility using the linear accelerator (linac) assets of the cancelled Superconducting Super Collider (SSC). The radioisotope production complex will serve as a domestic source of radioisotopes critically needed by the U.S. pharmaceutical industry and nuclear medicine facilities throughout North America. Presently, more than 70 percent of radioisotopes used in U.S. nuclear medicine procedures are produced outside the country. The Center's state-of-the-art proton cancer therapy facility will serve the Central United States, providing advanced capabilities and augmenting facilities in California and Massachusetts. Long-term, it is anticipated that the RMTC also will stimulate nuclear medicine research, advance medical diagnostic technologies, and generate new industrial applications of linear accelerator technology.

  1. Phase Noise Measurement in PEP II and the Linac

    Energy Technology Data Exchange (ETDEWEB)

    Getaneh, Mesfin

    2003-09-05

    The Goal of this project is to provide a measurement of the phase of the radio frequency (RF) relative to electron beam traveling down the Stanford Linear Accelerator Center (SLAC). Because the Main Drive Line (MDL) supplies the RF drive and phase reference for the entire accelerator system, the phase accuracy and amount of phase noise present in the MDL are very critical to the functionality of the accelerator. Therefore, a Phase Noise Measurement System was built to measure the phase noise in the liner accelerator (Linac) and PEP II. The system was used to determine the stability of the PEP II RF reference system. In this project a low noise Phase Locked Loop system (PLL) was built to measure timing jitter about sub picoseconds level. The phase noise measured in Master Oscillator using PLL indicates that phase noise is low enough for PEP II to run.

  2. SRF and RF systems for LEReC Linac

    Energy Technology Data Exchange (ETDEWEB)

    Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Brutus, J. C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fedotov, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); McIntyre, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Polizzo, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Smith, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Than, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tuozzolo, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Veshcherevich, V. [Cornell Univ., Ithaca, NY (United States); Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xiao, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xu, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Zaltsman, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The Low Energy RHIC electron Cooling (LEReC) is under development at BNL to improve RHIC luminosity at low energies. It will consist of a short electron linac and two cooling sections, one for blue and one for yellow rings. For the first stage of the project, LEReC-I, we will install a 704 MHz superconducting RF cavity and three normal conducting cavities operating at 9 MHz, 704 MHz and 2.1 GHz. The SRF cavity will boost the electron beam energy up to 2 MeV. The warm cavities will be used to correct the energy spread introduced in the SRF cavity. The paper describes layouts of the SRF and RF systems, their parameters and status.

  3. A study of multi-phase flow through the cathode side of an interdigitated flow field using a multi-fluid model

    DEFF Research Database (Denmark)

    Berning, Torsten; Odgaard, Madeleine; Kær, Søren Knudsen

    2010-01-01

    in the form of latent heat which reduces the load on the coolant. Finally we see that the micro-porous layer might help keep the gas diffusion layer substrate dry due to a potentially higher evaporation rate caused by a combination of the Kelvin effect and a larger specific surface area compared......This work presents a study of multi-phase flow through the cathode side of a polymer electrolyte membrane fuel cell employing an interdigitated flow field plate. A previously published model has been extended in order to account for phase change kinetics, and a comparison between the interdigitated...... flow field design and a conventional straight channel design has been conducted. It is found that the parasitic pressure drop in the interdigitated design is in the range of a few thousand Pa and could be reduced to a few hundred Pa by choosing diffusion media with high in-plane permeability...

  4. Autopilot regulation for the Linac4 H- ion source

    Science.gov (United States)

    Voulgarakis, G.; Lettry, J.; Mattei, S.; Lefort, B.; Costa, V. J. Correia

    2017-08-01

    Linac4 is a 160 MeV H- linear accelerator part of the upgrade of the LHC injector chain. Its cesiated surface H- source is designed to provide a beam intensity of 40-50mA. It is operated with periodical Cs-injection at typically 30 days intervals [1] and this implies that the beam parameters will slowly evolve during operation. Autopilot is a control software package extending CERN developed Inspector framework. The aim of Autopilot is to automatize the mandatory optimization and cesiation processes and to derive performance indicators, thus keeping human intervention minimal. Autopilot has been developed by capitalizing on the experience from manually operating the source. It comprises various algorithms running in real-time, which have been devised to: • Optimize the ion source performance by regulation of H2 injection, RF power and frequency. • Describe the performance of the source with performance indicators, which can be easily understood by operators. • Identify failures, try to recover the nominal operation and send warning in case of deviation from nominal operation. • Make the performance indicators remotely available through Web pages.Autopilot is at the same level of hierarchy as an operator, in the CERN infrastructure. This allows the combination of all ion source devices, providing the required flexibility. Autopilot is executed in a dedicated server, ensuring unique and centralized control, yet allowing multiple operators to interact at runtime, always coordinating between them. Autopilot aims at flexibility, adaptability, portability and scalability, and can be extended to other components of CERN's accelerators. In this paper, a detailed description of the Autopilot algorithms is presented, along with first results of operating the Linac4 H- Ion Source with Autopilot.

  5. Highly-wrinkled reduced graphene oxide-conductive polymer fibers for flexible fiber-shaped and interdigital-designed supercapacitors

    Science.gov (United States)

    Li, Bo; Cheng, Jianli; Wang, Zhuanpei; Li, Yinchuan; Ni, Wei; Wang, Bin

    2018-02-01

    Flexible supercapacitors have attracted great interest due to outstanding flexibility and light weight. Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) fibers have the great potential in using as electrodes for flexible supercapacitors due to the good flexibility. However, the reported conductivity and specific capacitance of these PEDOT: PSS fibers are not very high, which limit their electrochemical performances. In this work, composite fibers of reduced graphene oxide(rGO)-PEDOT: PSS with a highly-wrinkled structure on the surface and pores inside are prepared by wet spinning. The fibers with different ratios of graphene to PEDOT:PSS show a distinctly enhanced conductivity up to ca. 590 S·cm-1 and high strength up to ca. 18.4 MPa. Meanwhile, the composite fibers show an improved electrochemical performances, including a high specific areal capacitance of 131 mF cm-2 and high specific areal energy density of 4.55 μWh·cm-2. The flexible supercapacitors including fiber-shaped supercapacitors and interdigital designed supercapacitors not only could work in different bending states without obvious capacitance decay, but also have small leakage current. The interdigital design can further improve the performances of composite fibers with high capacitance and high utilization compared with traditional parallel connected structure.

  6. Interdigitated microelectrode array-coupled bipolar semiconductor photodiode array (IMEA-PDA) microchip for on-chip electrochemiluminescence detection.

    Science.gov (United States)

    Pal, Sukdeb; Kim, Min Jung; Tak, Yu Kyung; Kwon, Ho Taik; Song, Joon Myong

    2009-10-01

    This paper reports the design, fabrication and testing of a microchip wherein interdigitated microelectrode arrays (IMEA) were integrated with bipolar semiconductor photodiode array (PDA) chip to fabricate a highly compact embodiment for on-chip handling of solutions and electrochemiluminescence (ECL) detection. A 12 x 12 micro array of photodiodes, each coupled with an interdigitated microelectrode array (IMEA), an array of current amplifiers, and a photodiode element-addressing circuit were integrated into a single 2 x 2 cm² IC chip. Each photodiode had dimensions of 300 x 300 μm² and the photodiode-to-photodiode distance was 100 μm. The chip was successfully applied to the on-chip quantification of electro-chemiluminescing probe-labeled single stranded oligonucleotides. The minimum detectable limit at signal/noise ≥ 3 was found to be 5 x 10⁻¹⁴ moles of oligonucleotides with a sample volume as low as 5 microl (i.e., 10 fmole/μl). The attractive features of the developed IMEA-PDA microchip are that a plurality of samples can be analyzed simultaneously using a chip and that for a given sample the data can be averaged from values obtained from multiple, individually addressed pixels. These in turn bring in speed and statistical confidence in analysis. The IMEA-PDA microchip system has the potential to be used as a versatile and highly compact chemical analysis tool for chemical sensing and metrology applications.

  7. Stereotactic radiosurgery for intracranial metastases: linac-based and gamma-dedicated unit approach.

    Science.gov (United States)

    Alongi, Filippo; Fiorentino, Alba; Mancosu, Pietro; Navarria, Pierina; Giaj Levra, Niccolò; Mazzola, Rosario; Scorsetti, Marta

    2016-07-01

    For intracranial metastases, the role of stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy is well recognized. Historically, the first technology, for stereotactic device able to irradiate a brain tumor volume, was Gamma Knife® (GK). Due to the technological advancement of linear accelerator (Linac), there was a continuous increasing interest in SRS Linac-based applications. In those decades, it was assumed a superiority of GK compared to SRS Linac-based for brain tumor in terms of dose conformity and rapid fall-off dose close to the target. Expert commentary: Recently, due to the Linac technologic advancement, the choice of SRS GK-based is not necessarily so exclusive. The current review discussed in details the technical and clinical aspects comparing the two approaches for brain metastases.

  8. Transverse beam resonance in the superconducting linac of the Spallation Neutron Source

    Directory of Open Access Journals (Sweden)

    Y. Zhang

    2010-04-01

    Full Text Available A weak transverse resonance in the Spallation Neutron Source (SNS superconducting linac is identified in computer simulations, and is believed to be one of the mechanisms behind measured beam losses. This weak resonance is induced by the nonlinear dodecapole component of the linac quadrupole magnets. It occurs when the linac focusing lattice has a transverse phase advance close to 60°. By reducing the phase advance to approximately 50° to avoid the resonance, we observe significant reduction in beam loss in the SNS superconducting linac. We present theory and computer simulation results supporting the notion that a suppression of the 60° resonance may contribute to reduction in the beam loss.

  9. Time-Resolved Emittance Characterization of an Induction Linac Beam using Optical Transition Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Le Sage, G P

    2002-11-05

    An induction linac is used by Lawrence Livermore National Laboratory to perform radiographic testing at the Flash X-ray Radiography facility. Emittance characterization is important since x-ray spot size impacts the resolution of shadow-graphs. Due to the long pulse length, high current, and beam energy, emittance measurement using Optical Transition Radiation is an attractive alternative for reasons that will be described in the text. The utility of OTR-based emittance measurement has been well demonstrated for both RF and induction linacs. We describe the time-resolved emittance characterization of an induction linac electron beam. We have refined the optical collection system for the induction linac application, and have demonstrated a new technique for probing the divergence of a subset of the beam profile. The experimental apparatus, data reduction, and conclusions will be presented. Additionally, a new scheme for characterizing the correlation between beam divergence and spatial coordinates within the beam profile will be described.

  10. X-band Linac for a 6 MeV dual-head radiation therapy gantry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hyun; Shin, Seung-Wook; Lee, Jongchul; Kim, Hui-Su [WCU Department of Energy Science, Suwon 440-746 (Korea, Republic of); Lee, Byeong-No; Lee, Byung-Chul [Radiation Instrumentation Research Division, Korea Atomic Energy Research Institute, Jeongeup 56212 (Korea, Republic of); Park, Hyung-dal; Song, Ki-back [Radiation Technology eXcellence (RTX), Daejeon 305-500 (Korea, Republic of); Song, Ho-seung; Mun, Sangchul; Ha, Donghyup [School of Information and Communication Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Chai, Jong-Seo, E-mail: jschai@skku.edu [School of Information and Communication Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2017-04-21

    We developed a design for a 6 MeV X-band linear accelerator for radiation therapy in a dual-head gantry layout. The dual-head gantry has two linacs that can be operated independently. Each X-band linac accelerates electron bunches using high-power RF and generates X-rays for radiation therapy. It requires a versatile RF system and pulse sequence to accomplish various radiation therapy procedures. The RF system consists of 9.3 GHz, 2 MW X-band magnetron and associated RF transmission components. A test linac was assembled and operated to characterize its RF performance without beam. This paper presents these results along with a description of the gantry linacs and their operational requirements.

  11. First Considerations Concerning an Optimized Cavity Design for the Main Linac of BERLinPro

    Energy Technology Data Exchange (ETDEWEB)

    B. Riemann, T. Weis, W. Anders, J. Knobloch, A. Neumann, H.-W. Glock, C. Potratz, U. van Rienen, F. Marhauser

    2011-09-01

    The Berlin Energy Recovery Linac Project (BERLinPro) is designed to develop and demonstrate CW linac technology and expertise required to drive next-generation Energy Recovery Linacs. Strongly HOM-damped multicell 1.3 GHz cavities are required for the main linac. The optimization of the cavities presented here is primarily based on the CEBAF 1.5 GHz 5-cell high-current cavity design, including HOM waveguide couplers. The cavity was scaled to 1.3 GHz and extended to 7 cells. Modifications to the end group design have also been studied. An effort was also made to reduce the ratio Epk/Eacc while still permitting HOMs to propagate.

  12. Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN

    CERN Document Server

    Zocca, F; Duraffourg, M; Focker, G J; Gerard, D; Kolad, B; Lenardon, F; Ludwig, M; Raich, U; Roncarolo, F; Sordet, M; Tan, J; Tassan-Viol, J; Vuitton, C; Feshenko, A

    2014-01-01

    As part of the CERN LHC injector chain upgrade, LINAC4 [1, 2] will accelerate H- ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, have been commissioned in the LINAC4 tunnel. Diagnostic devices are installed in the LEBT and MEBT line and in a movable diagnostics test bench which is temporarily added to the MEBT exit. The paper gives an overview of all the instruments used, including beam current transformers, beam position monitors, wire scanners and wire grids for transverse profile measurements, a longitudinal bunch shape monitor and a slit-and-grid emittance meter. The instrumentation performance is discussed and the measurement results that allowed characterizing the 3 MeV beam in the LINAC4 tunnel are summarized.

  13. DESIGN AND FABRICATION OF THE BEAM POSITION MONITOR FOR THE PEFP LINAC

    Directory of Open Access Journals (Sweden)

    HYEOK-JUNG KWON

    2013-08-01

    Full Text Available The beam position monitor (BPM is an essential component for the PEFP 100-MeV linac's commissioning. A prototype stripline-type linac BPM was designed for this purpose. The electrode aperture is 20 mm in diameter, and the electrode is 25 mm long, so it can be installed between Drift Tube Linac (DTL101 and DTL102, which is the shortest distance. One end of the electrode is connected to the Sub Miniature Type A (SMA feed through for signal measurement, and the other end is terminated as a short. The signal amplitude of the fundamental component was calculated and compared with that of the second harmonic component. The designed BPM was fabricated and a low-power RF test was conducted. In this paper, the design, fabrication and low power test of the BPM for the PEFP linac are presented.

  14. On the beam dynamics optimization problem for an alternating-phase focusing linac

    Science.gov (United States)

    Ovsyannikov, D. A.; Altsybeyev, V. V.

    2016-12-01

    A new algorithm for generation a synchronous phase sequence in alternating-phase focusing (APF) linacs is proposed. The optimization of the intense deuteron beam is considered. The results of the numerical optimization are presented.

  15. Time-Resolved Emittance Characterization of an Induction Linac Beam using Optical Transition Radiation

    CERN Document Server

    Le Sage, G P

    2002-01-01

    An induction linac is used by Lawrence Livermore National Laboratory to perform radiographic testing at the Flash X-ray Radiography facility. Emittance characterization is important since x-ray spot size impacts the resolution of shadow-graphs. Due to the long pulse length, high current, and beam energy, emittance measurement using Optical Transition Radiation is an attractive alternative for reasons that will be described in the text. The utility of OTR-based emittance measurement has been well demonstrated for both RF and induction linacs. We describe the time-resolved emittance characterization of an induction linac electron beam. We have refined the optical collection system for the induction linac application, and have demonstrated a new technique for probing the divergence of a subset of the beam profile. The experimental apparatus, data reduction, and conclusions will be presented. Additionally, a new scheme for characterizing the correlation between beam divergence and spatial coordinates within the b...

  16. HOM Consideration of 704 MHz and 2.1 GHz Cavities for LEReC Linac

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Binping [RIKEN BNL; Belomestnykh, Sergey [SUNY, Stony Brook; Ben-Zvi, Ilan [RIKEN BNL; Blaskiewicz, Michael [RIKEN BNL; Brennan, Joseph [RIKEN BNL; Brutus, Jean Clifford [RIKEN BNL; Fedotov, Alexei [RIKEN BNL; Hahn, Harald [RIKEN BNL; McIntyre, Gary [RIKEN BNL; Pai, Chien [RIKEN BNL; Smith, Kevin [RIKEN BNL; Tuozzolo, Joseph [RIKEN BNL; Veshcherevich, Vadim [Cornell U., CLASSE; Wu, Qiong [RIKEN BNL; Xin, Tianmu [RIKEN BNL; Xu, Wencan [RIKEN BNL; Zaltsman, Alex [RIKEN BNL

    2016-06-01

    To improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, the Low Energy RHIC electron Cooler (LEReC) is currently under development at BNL. The Linac of LEReC is designed to deliver 2 MV to 5 MV electron beam, with rms dp/p less than 5·10⁻⁴. The HOM in this Linac is carefully studied to ensure this specification.

  17. Simulations and cold-test results of a prototype plane wave transformer linac structure

    Directory of Open Access Journals (Sweden)

    Arvind Kumar

    2002-03-01

    Full Text Available We have built a 4-cell prototype plane wave transformer (PWT linac structure. We discuss here details of the design and fabrication of the PWT linac structure. We present results from superfish and gdfidl simulations as well as cold tests, which are in good agreement with each other. We also present detailed tolerance maps for the PWT structure. We discuss beam dynamics simulation studies performed using parmela.

  18. Longitudinal Space Charge Effects in the JLAB IR FEL SRF Linac

    CERN Document Server

    Hernandez-Garcia, Carlos; Behre, Chris; Benson, S V; Herman-Biallas, George; Boyce, James; Douglas, David; Dylla, Fred; Evans, Richard; Grippo, A; Gubeli, Joe; Hardy, David; Jordan, Kevin; Merminga, Lia; Neil, George; Preble, Joe; Shinn, Michelle D; Siggins, Tim; Walker, Richard; Williams, Gwyn; Yunn, Byung; Zhang, Shukui

    2004-01-01

    Observations of energy spread asymmetry when operating the Linac on either side of crest and longitudinal emittance growth have been confirmed by extending PARMELA simulations from the injector to the end of the first SRF Linac module. The asymmetry can be explained by the interaction of the accelerating electric field with that from longitudinal space charge effects within the electron bunch. This can be a major limitation to performance in FEL accelerators.

  19. Choke-Mode Damped Structure Design for the CLIC Main Linac

    OpenAIRE

    Zha, Hao; Chen, Huaibi; Tang, Chuanxiang; Huang, Wenhui; Shi, Jiaru; Grudiev, Alexej; Wuensch, Walter

    2012-01-01

    Choke-mode damped structures are being studied as an alternative design for the accelerating structures of main linacs of the compact linear collider (CLIC). Choke-mode structures have the potential for much lower pulsed temperature rise, and lower cost of manufacture and fabrication. A new kind of choke-mode structure was proposed and simulated by Gdfidl. This structures has comparable wakefield damping effect as the baseline design of CLIC main linacs.

  20. Superconducting resonator used as a phase and energy detector for linac setup

    Directory of Open Access Journals (Sweden)

    Nikolai R. Lobanov

    2016-07-01

    Full Text Available Booster linacs for tandem accelerators and positive ion superconducting injectors have matured into standard features of many accelerator laboratories. Both types of linac are formed as an array of independently-phased resonators operating at room temperature or in a superconducting state. Each accelerating resonator needs to be individually set in phase and amplitude for optimum acceleration efficiency. The modularity of the linac allows the velocity profile along the structure to be tailored to accommodate a wide range charge to mass ratio. The linac setup procedure, described in this paper, utilizes a superconducting resonator operating in a beam bunch phase detection mode. The main objective was to derive the full set of phase distributions for quick and efficient tuning of the entire accelerator. The phase detector was operated in overcoupling mode in order to minimize de-tuning effects of microphonic background. A mathematical expression was derived to set a limit on resonator maximum accelerating field during the crossover search to enable extracting unambiguous beam phase data. A set of equations was obtained to calculate the values of beam phase advance and energy gain produced by accelerating resonators. An extensive range of linac setting up configurations was conducted to validate experimental procedures and analytical models. The main application of a superconducting phase detector is for fast tuning for beams of ultralow intensities, in particular in the straight section of linac facilities.

  1. Beam dynamics and commissioning of low and medium energy H- beam at Linac4

    CERN Document Server

    Satri, Masoomeh Yarmohammadi; Lombardi, Alessandra; Lamehi-Rachti , Mohammad

    The First step of the CERN Large Hadron Collider injectors upgrade (LIU) project is Linac4. It accelerates H- ions to 160 MeV in an 80 m long accelerator housed in a tunnel 12 m underground, presently under construction. It will replace the present 50 MeV proton Linac2 as injector of the proton accelerator complex to increase the LHC luminosity. It consists of a 45 keV RF volume source, a twosolenoid Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ) accelerating the beam to 3 MeV, a Medium Energy Beam Transport (MEBT) line. The MEBT houses a fast chopper to selectively remove unwanted micro-bunches in the 352 MHz sequence and avoid losses at capture in the CERN PSB (1 MHz). After chopping, the beam acceleration continues by a 50 MeV Drift Tube Linac (DTL), a 100 MeV Cell-Coupled Drift Tube Linac and a Pi-Mode Structure bringing the beam to the final energy of 160 MeV. Linac4 has been commissioned with a temporary source up to 12 MeV. The beam commissioning stages of Linac4 in LEBT...

  2. Design of the NSLS-II Linac Front End Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Fliller III, R.; Johanson, M.; Lucas, M.; Rose, J.; Shaftan, T.

    2011-03-28

    The NSLS-II operational parameters place very stringent requirements on the injection system. Among these are the charge per bunch train at low emittance that is required from the linac along with the uniformity of the charge per bunch along the train. The NSLS-II linac is a 200 MeV linac produced by Research Instruments Gmbh. Part of the strategy for understanding to operation of the injectors is to test the front end of the linac prior to its installation in the facility. The linac front end consists of a 100 kV electron gun, 500 MHz subharmonic prebuncher, focusing solenoids and a suite of diagnostics. The diagnostics in the front end need to be supplemented with an additional suite of diagnostics to fully characterize the beam. In this paper we discuss the design of a test stand to measure the various properties of the beam generated from this section. In particular, the test stand will measure the charge, transverse emittance, energy, energy spread, and bunching performance of the linac front end under all operating conditions of the front end.

  3. Proposal for Reduction of Transverse Emittance of BNL 200 MeV Linac

    CERN Document Server

    Alessi, J; Raparia, D; Weng, W T

    2004-01-01

    BNL plans to upgrade the AGS proton beam from the current 0.14 MW to higher than 1.0 MW and beyond for such a neutrino facility which consists of two major subsystems. First is a 1.2 GeV super-conducting linac (SCL) to replace the booster as injector for the AGS. Second is the performance upgrade for the AGS itself for the higher intensity and repetition rate. For high intensity proton accelerators, such as the upgraded AGS, there are very stringent limitations on uncontrolled beam losses. A direct effect of linac beam emittance is the halo/tail generation in the circulating beam. Studies show the estimated halo/tail generation in the beam for present normalized RMS emittance of linac beam is unacceptable. To reduce the transverse emittance of 200 MeV linac, the existing radio frequency quadrupole linac (RFQ) has to be relocated closer to drift tube linac (DTL) tank 1 to meet emittance requirement for the AGS injection with low loss. This paper will present the various options of matching between RFQ and DTL,...

  4. submitter Radiation Protection Studies for CERN LINAC4/SPL Accelerator Complex

    CERN Document Server

    Mauro, Egidio; Silari, Marco

    2009-01-01

    CERN is presently designing a new chain of accelerators to replace the present Proton Synchrotron (PS) complex: a 160 MeV room-temperature H$^-$ linac (Linac4) to replace the present 50 MeV proton linac injector, a 3.5 GeV Superconducting Proton Linac (SPL) to replace the 1.4 GeV PS booster (PSB) and a 50 GeV synchrotron (named PS2) to replace the 26 GeV PS. Linac4 has been funded and the civil engineering work started in October 2008, whilst the SPL is in an advanced stage of design. Beyond injecting into the future 50 GeV PS, the ultimate goal of the SPL is to generate a 4 MW beam for the production of intense neutrino beams. The radiation protection design is driven by the latter requirement. This thesis summarizes the radiation protection studies conducted for Linac4. FLUKA Monte Carlo simulations, complemented by analytical estimates, were performed 1) to evaluate the propagation of neutrons through the waveguide, ventilation and cable ducts placed along the accelerator, 2) to estimate the radiological i...

  5. Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system.

    Science.gov (United States)

    Santos, D M; St Aubin, J; Fallone, B G; Steciw, S

    2012-02-01

    In our current linac-magnetic resonance (MR) design, a 6 MV in-line linac is placed along the central axis of the MR's magnet where the MR's fringe magnetic fields are parallel to the overall electron trajectories in the linac waveguide. Our previous study of this configuration comprising a linac-MR SAD of 100 cm and a 0.5 T superconducting (open, split) MR imager. It showed the presence of longitudinal magnetic fields of 0.011 T at the electron gun, which caused a reduction in target current to 84% of nominal. In this study, passive and active magnetic shielding was investigated to recover the linac output losses caused by magnetic deflections of electron trajectories in the linac within a parallel linac-MR configuration. Magnetic materials and complex shield structures were used in a 3D finite element method (FEM) magnetic field model, which emulated the fringe magnetic fields of the MR imagers. The effects of passive magnetic shielding was studied by surrounding the electron gun and its casing with a series of capped steel cylinders of various inner lengths (26.5-306.5 mm) and thicknesses (0.75-15 mm) in the presence of the fringe magnetic fields from a commercial MR imager. In addition, the effects of a shield of fixed length (146.5 mm) with varying thicknesses were studied against a series of larger homogeneous magnetic fields (0-0.2 T). The effects of active magnetic shielding were studied by adding current loops around the electron gun and its casing. The loop currents, separation, and location were optimized to minimize the 0.011 T longitudinal magnetic fields in the electron gun. The magnetic field solutions from the FEM model were added to a validated linac simulation, consisting of a 3D electron gun (using OPERA-3d/scala) and 3D waveguide (using comsol Multiphysics and PARMELA) simulations. PARMELA's target current and output phase-space were analyzed to study the linac's output performance within the magnetic shields. The FEM model above agreed within 1

  6. Unfolding linac photon spectra and incident electron energies from experimental transmission data, with direct independent validation.

    Science.gov (United States)

    Ali, E S M; McEwen, M R; Rogers, D W O

    2012-11-01

    In a recent computational study, an improved physics-based approach was proposed for unfolding linac photon spectra and incident electron energies from transmission data. In this approach, energy differentiation is improved by simultaneously using transmission data for multiple attenuators and detectors, and the unfolding robustness is improved by using a four-parameter functional form to describe the photon spectrum. The purpose of the current study is to validate this approach experimentally, and to demonstrate its application on a typical clinical linac. The validation makes use of the recent transmission measurements performed on the Vickers research linac of National Research Council Canada. For this linac, the photon spectra were previously measured using a NaI detector, and the incident electron parameters are independently known. The transmission data are for eight beams in the range 10-30 MV using thick Be, Al and Pb bremsstrahlung targets. To demonstrate the approach on a typical clinical linac, new measurements are performed on an Elekta Precise linac for 6, 10 and 25 MV beams. The different experimental setups are modeled using EGSnrc, with the newly added photonuclear attenuation included. For the validation on the research linac, the 95% confidence bounds of the unfolded spectra fall within the noise of the NaI data. The unfolded spectra agree with the EGSnrc spectra (calculated using independently known electron parameters) with RMS energy fluence deviations of 4.5%. The accuracy of unfolding the incident electron energy is shown to be ∼3%. A transmission cutoff of only 10% is suitable for accurate unfolding, provided that the other components of the proposed approach are implemented. For the demonstration on a clinical linac, the unfolded incident electron energies and their 68% confidence bounds for the 6, 10 and 25 MV beams are 6.1 ± 0.1, 9.3 ± 0.1, and 19.3 ± 0.2 MeV, respectively. The unfolded spectra for the clinical linac agree with the

  7. Preparation and gas sensing properties of nanocomposite polymers on micro-Interdigitated electrodes for detection of volatile organic compounds at room temperature

    NARCIS (Netherlands)

    Nguyen, Quyen; Kuijk, Anke; Pujari, Sidharam P.; Bent, van de Franc; Baggerman, Jacob; Duy Tong, Hien; Zuilhof, Han; Rijn, van Cees J.M.

    2017-01-01

    A room-temperature chemocapacitive gas sensor based on polymeric nanocomposites (NCs) consisting of amine-terminated silicon nanoparticles (Si NPs-NH2) and poly (4-vinylphenol) was fabricated on a micro-gap interdigitated electrode (M-IDE), and used for the detection of acetone.

  8. Insights on Capacitive Interdigitated Electrodes Coated with MOF Thin Films: Humidity and VOCs Sensing as a Case Study

    KAUST Repository

    Sapsanis, Christos

    2015-07-24

    A prototypical metal-organic framework (MOF), a 2D periodic porous structure based on the assembly of copper ions and benzene dicarboxylate (bdc) ligands (Cu(bdc)·xH2O), was grown successfully as a thin film on interdigitated electrodes (IDEs). IDEs have been used for achieving planar CMOS-compatible low-cost capacitive sensing structures for the detection of humidity and volatile organic compounds (VOCs). Accordingly, the resultant IDEs coated with the Cu(bdc)·xH2O thin film was evaluated, for the first time, as a capacitive sensor for gas sensing applications. A fully automated setup, using LabVIEW interfaces to experiment conduction and data acquisition, was developed in order to measure the associated gas sensing performance.

  9. Insights on Capacitive Interdigitated Electrodes Coated with MOF Thin Films: Humidity and VOCs Sensing as a Case Study

    Directory of Open Access Journals (Sweden)

    Christos Sapsanis

    2015-07-01

    Full Text Available A prototypical metal-organic framework (MOF, a 2D periodic porous structure based on the assembly of copper ions and benzene dicarboxylate (bdc ligands (Cu(bdc·xH2O, was grown successfully as a thin film on interdigitated electrodes (IDEs. IDEs have been used for achieving planar CMOS-compatible low-cost capacitive sensing structures for the detection of humidity and volatile organic compounds (VOCs. Accordingly, the resultant IDEs coated with the Cu(bdc·xH2O thin film was evaluated, for the first time, as a capacitive sensor for gas sensing applications. A fully automated setup, using LabVIEW interfaces to experiment conduction and data acquisition, was developed in order to measure the associated gas sensing performance.

  10. Interdigitated 50 nm Ti electrode arrays fabricated using XeF{sub 2} enhanced focused ion beam etching

    Energy Technology Data Exchange (ETDEWEB)

    Santschi, Ch [Laboratoire de Microsystemes (LMIS), Station 17, CH1015 Lausanne (Switzerland); Jenke, M [Laboratoire d' Optique Appliquee (LOA), Ecole Polytechnique Federale de Lausanne, Station 17, CH1015 Lausanne (Switzerland); Hoffmann, P [Laboratoire d' Optique Appliquee (LOA), Ecole Polytechnique Federale de Lausanne, Station 17, CH1015 Lausanne (Switzerland); Brugger, J [Laboratoire de Microsystemes (LMIS), Station 17, CH1015 Lausanne (Switzerland)

    2006-06-14

    The fabrication of interdigitated titanium nanoelectrode arrays of 50 nm in width and spacing is described in this work. The nanoarrays have been realized using a Ga{sup +} focused ion beam (FIB). FIB milling is typically accompanied by redeposition of removed material, which represents an important hindrance for milling closely spaced nanostructures. Redeposition effects have been reduced by means of XeF{sub 2} gas assistance, which increases the etch yield by a factor of seven compared with pure ion milling. Furthermore, we used a simple adsorption model, which led to the conclusion that dwell time and refresh time should be <500 ns and >30 ms, respectively, for optimized XeF{sub 2} assisted Ti milling. The measured resistance R of the electrodes is higher than 1 G{omega}.

  11. H2S Sensors: Fumarate-Based fcu-MOF Thin Film Grown on a Capacitive Interdigitated Electrode.

    Science.gov (United States)

    Yassine, Omar; Shekhah, Osama; Assen, Ayalew H; Belmabkhout, Youssef; Salama, Khaled N; Eddaoudi, Mohamed

    2016-12-19

    Herein we report the fabrication of an advanced sensor for the detection of hydrogen sulfide (H 2 S) at room temperature, using thin films of rare-earth metal (RE)-based metal-organic framework (MOF) with underlying fcu topology. This unique MOF-based sensor is made via the in situ growth of fumarate-based fcu-MOF (fum-fcu-MOF) thin film on a capacitive interdigitated electrode. The sensor showed a remarkable detection sensitivity for H 2 S at concentrations down to 100 ppb, with the lower detection limit around 5 ppb. The fum-fcu-MOF sensor exhibits a highly desirable detection selectivity towards H 2 S vs. CH 4 , NO 2 , H 2 , and C 7 H 8 as well as an outstanding H 2 S sensing stability as compared to other reported MOFs. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Capacitance Variation Induced by Microfluidic Two-Phase Flow across Insulated Interdigital Electrodes in Lab-On-Chip Devices

    Directory of Open Access Journals (Sweden)

    Tao Dong

    2015-01-01

    Full Text Available Microfluidic two-phase flow detection has attracted plenty of interest in various areas of biology, medicine and chemistry. This work presents a capacitive sensor using insulated interdigital electrodes (IDEs to detect the presence of droplets in a microchannel. This droplet sensor is composed of a glass substrate, patterned gold electrodes and an insulation layer. A polydimethylsiloxane (PDMS cover bonded to the multilayered structure forms a microchannel. Capacitance variation induced by the droplet passage was thoroughly investigated with both simulation and experimental work. Olive oil and deionized water were employed as the working fluids in the experiments to demonstrate the droplet sensor. The results show a good sensitivity of the droplet with the appropriate measurement connection. This capacitive droplet sensor is promising to be integrated into a lab-on-chip device for in situ monitoring/counting of droplets or bubbles.

  13. Insights on Capacitive Interdigitated Electrodes Coated with MOF Thin Films: Humidity and VOCs Sensing as a Case Study.

    Science.gov (United States)

    Sapsanis, Christos; Omran, Hesham; Chernikova, Valeriya; Shekhah, Osama; Belmabkhout, Youssef; Buttner, Ulrich; Eddaoudi, Mohamed; Salama, Khaled N

    2015-07-24

    A prototypical metal-organic framework (MOF), a 2D periodic porous structure based on the assembly of copper ions and benzene dicarboxylate (bdc) ligands (Cu(bdc)·xH2O), was grown successfully as a thin film on interdigitated electrodes (IDEs). IDEs have been used for achieving planar CMOS-compatible low-cost capacitive sensing structures for the detection of humidity and volatile organic compounds (VOCs). Accordingly, the resultant IDEs coated with the Cu(bdc)·xH2O thin film was evaluated, for the first time, as a capacitive sensor for gas sensing applications. A fully automated setup, using LabVIEW interfaces to experiment conduction and data acquisition, was developed in order to measure the associated gas sensing performance.

  14. Interdigitated electrode (IDE) for porcine detection based on titanium dioxide (TiO{sub 2}) thin films

    Energy Technology Data Exchange (ETDEWEB)

    Nordin, N.; Azizah, N. [Institute of Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000 Kangar Perlis (Malaysia); Hashim, U., E-mail: uda@unimap.edu.my [Institute of Electronic Engineering (INEE), Universiti Malaysia Perlis, 01000 Kangar Perlis (Malaysia); School of Microelctronic Engineering, Universiti Malaysia Perlis, 01000 Kangar Perlis (Malaysia)

    2016-07-06

    Interdigited Electrode (IDE) porcine detection can be accomplished to authenticate the halal issue that has been a concern to Muslim not only in Malaysia but all around the world. The method used is photolithography that used the p-type photoresist on the spin coater with 2500 rpm. Bare IDEs device is deposited with Titanium Dioxide (TiO{sub 2}) to improve the performance of the device. The result indicates that current-voltage (I-V) measurement of porcine probe line slightly above porcine target due to negative charges repelled each other. The IDE device can detect the porcine presence in food as lowest as 1.0 µM. Better performance of the device can be achieved with the replacement of gold deposited to trigger more sensitivity of the device.

  15. LINAC4 - Views of the 3 MeV Front-end (H- Source, LEBT, RFQ, MEBT) with Test Bench.

    CERN Multimedia

    Anna Pantelia

    2013-01-01

    The Linac4 is the new linear accelerator that will replace Linac2 as proton low energy injector in the LHC accelerator chain. On 14 November, members of the Linac4 collaboration and the CERN Operation Group were brought together for their first “real day” in the Linac4 Control Room. Together, they successfully accelerated their first hydrogen ion beam to 3 MeV. It was an exciting moment for everyone involved marked the start of one of the most critical commissioning phases for the new accelerator.

  16. MARS15 Simulation of Radiation Environment at the ESS Linac

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N. V. [Fermilab; Eidelman, Yu. I. [Euclid Techlabs, Solon; Rakhno, I. L. [Fermilab; Tchelidze, L. [ESS, Lund; Tropin, I. S. [Fermilab

    2016-12-01

    Comprehensive studies with the MARS15(2016) Monte-Carlo code are described on evaluation of prompt and residual radiation levels induced by nominal and accidental beam losses in the 5-MW, 2-GeV European Spallation Source (ESS) Linac. These are to provide a basis for radiation shielding design verification through the accelerator complex. The calculation model is based on the latest engineering design and includes a sophisticated algorithm for particle tracking in the machine RF cavities as well as a well-established model of the beam loss. Substantial efforts were put in solving the deep-penetration problem for the thick shielding around the tunnel with numerous complex penetrations. It allowed us to study in detail not only the prompt dose, but also component and air activation, radiation loads on the soil outside the tunnel, and skyshine studies for the complicated 3-D surface above the machine. Among the other things, the newest features in MARS15 (2016), such as a ROOT-based beamline builder and a TENDL-based event generator for nuclear interactions below 100 MeV, were very useful in this challenging application

  17. RF-chopper for the JHF proton linac

    CERN Document Server

    Fu Shin Ian

    2000-01-01

    An RF-chopper possesses merits in both its high deflecting field and compactness. For this reason, it is suitable for chopping a high-current beam in a medium-energy beam-transport line (MEBT) of an ion linear accelerator. The JHF linac, as a high-current H sup - accelerator with an average current of up to 0.2 mA or higher in the second phase, took these advantages of the RF-chopper in its design. Two RF-deflecting cavities as the chopper will be used in the MEBT just downward of the 3-MeV 324-MHz RFQ. A 324-MHz RF-chopper cavity has been designed with optimization for a fast rise/fall time, which is an essential requirement for the chopper in a high-current accelerator in order to avoid radioactivity induced by the lost particles due to insufficient chopping during the transient time. The rise time can be less than 8 ns by means of a pair of ports with large coupling loops. In this paper, the details concerning the R and D of the RF-chopper are presented. Some RF properties calculated with MAFIA and HFSS co...

  18. RF Design for the Linac Coherent Light Source (LCLS) Injector

    CERN Document Server

    Dowell, D H; Boyce, Richard F; Hodgson, J A; Li, Zenghai; Limborg-Deprey, C; Xiao, Liling; Yu, Nancy

    2004-01-01

    The Linac Coherent Light Source (LCLS) will be the world’s first free electron laser, and the successful operation of this very short-wavelength FEL will require excellent beam quality from its electron source. Therefore a critical component is the RF photocathode injector. This paper describes the design issues of the LCLS RF gun and accelerator structures. The injector consists of a 1.6 cell s-band gun followed by two 3-meter SLAC sections. The gun and the first RF section will have dual RF feeds both to eliminate transverse RF kicks and to reduce the pulsed heating of the coupling ports. In addition, the input coupler cavity of the first accelerator section will be specially shaped to greatly reduce the RF quadrupole fields. The design for the accelerator section is now complete, and the RF design of the gun’s dual coupler and the full cell shape is in progress. These and other aspects of the gun and structure designs will be discussed.

  19. Vacuum system of the compact Energy Recovery Linac

    Energy Technology Data Exchange (ETDEWEB)

    Honda, T., E-mail: tohru.honda@kek.jp; Tanimoto, Y.; Nogami, T.; Takai, R.; Obina, T.; Asaoka, S.; Uchiyama, T.; Nakamura, N. [High Energy Accelerator Research Organization (KEK) (1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan) (Japan)

    2016-07-27

    The compact Energy Recovery Linac (cERL), a test accelerator to establish important technologies demanded for future ERL-based light sources, was constructed in late 2013 at KEK. The accelerator was successfully commissioned in early 2014, and demonstrated beam circulation with energy recovery. In the cERL vacuum system, low-impedance vacuum components are required to circulate high-intensity, low-emittance and short-bunch electron beams. We therefore developed ultra-high-vacuum (UHV)-compatible flanges that can connect beam tubes seamlessly, and employed retractable beam monitors, namely, a movable Faraday cup and screen monitors. In most parts of the accelerator, pressures below 1×10{sup −7} Pa are required to mitigate beam-gas interactions. Particularly, near the photocathode electron gun and the superconducting (SC) cavities, pressures below 1×10{sup −8} Pa are required. The beam tubes in the sections adjoining the SC cavities were coated with non-evaporable getter (NEG) materials, to reduce gas condensation on the cryo-surfaces. During the accelerator commissioning, stray magnetic fields from the permanent magnets of some cold cathode gauges (CCGs) were identified as a source of the disturbance to the beam orbit. Magnetic shielding was specially designed as a remedy for this issue.

  20. Analytical treatment of single bunch stability in a linac

    CERN Document Server

    Guignard, Gilbert

    1998-01-01

    Single bunch stability is analysed by solving the equation of motion of the particles travelling in a linac, for a Gaussian distribution of charge, a linear variation of the transverse wakefield along the bunch, a smooth focusing and negligible acceleration. The treatment is based on a non-standard perturbation expansion that has been specifically developed for this study and preserves at each order the intrinsic detuning likely to stabilise the resonant beam break-up. It provides a closed expression for the tune shift along the bunch resulting from BNS damping and autophasing, methods proposed in the past to control the emittance, and a first­order solution for the transverse off­sets within the bunch. The analytic result obtained makes it possible to study the behaviour of the solution and compute the emittance dilution in specific cases. The present theory is a useful complement to the numerical simulations done with the MUSTAFA code in the Compact Linear Collider scheme (CLIC). It also gives an interest...

  1. The RF Design of the Linac4 RFQ

    CERN Document Server

    Piquet, Olivier; Desmons, Michel; France, Alain; Lombardi, Alessandra; Rossi, Carlo; Vretenar, Maurizio

    2010-01-01

    In the Linac 4 and the SPL, a 3 MeV RFQ is required to accelerate the Hbeam from the ion source to the DTL input energy. While the 6-meter long IPHI RFQ was initially chosen for this application, a CERN study suggested that a dedicated, shorter 3-meter RFQ might present several advantages. The 2D cross-section is optimized for lower power dissipation, while featuring simple geometrical shape suitable for easy machining. RF stability is evaluated using a 4-wire transmission model and 3D simulations, taking electrode modulation into account. The resulting RFQ is intrinsically stable and does not require rod stabilizers. End circuits are tuned with dedicated rods. RF power is fed via a ridged waveguide and a slot iris. Vacuum port assemblies are positioned prior to brazing to minimize RF perturbation. The 32 tuning slugs form a set of stable sampling, able to tune 9 modes. Tuner parameters are derived from beadpull accuracy specification and fabrication tolerances. Signals delivered by pickup loops inserted in 1...

  2. Outcome of LINAC radiosurgery for a cavernous angioma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Se Mie; Chie, Eui Kyu; Kim, Il Han; Ha, Sung Whan; Park, Charn Il [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of); Park, Suk Won [College of Medicine, Halym Univ., Seoul (Korea, Republic of)

    2003-03-01

    To establish the role of stereotactic radiosurgery using a linear accelerator for the treatment of patients with cavernous angioma. Between February 1995 and May 1997, 11 patients with cavernous angioma were treated with stereotactic radiosurgery using a linear accelerator. Diagnoses were based on the magnetic resonance imaging in 8 patients, and the histological in 3. The vascular lesions were located in the brainstem (5 cases), cerebellum (2 cases) thalamus (1 case) and cerebrum (3 cases), The clinical presentation at onset included previous intracerebral hemorrhages (9 cases) and seizures (2 cases). All patients were treated with a linac-based radiosurgery. The median dose of radiation delivered was 16 Gy ranging from 14 to 24 Gy, which was typically prescribed to the 80% isodose surface (range 50-80%), corresponding to the periphery of the lesion with a single isocenter. Ten patients were followed-up. The median follow-up was 49 months ranging from 8 to 73 months, during which time two patients developed an intracerebral hemorrhage, 1 at 8 months, with the other at 64 months post radiosurgery. One patient developed neurological deficit after radiosurgery, and two developed an edema on the T2 weighted images of the MRI surrounding the radiosurgical target. The use of stereotactic radiosurgery in the treatment of a cavernous angioma may be effective in the prevention of rebleeding, and can be safely delivered. However, a longer follow-up period will be required.

  3. Linac4 H{sup −} ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Lettry, J., E-mail: Jacques.lettry@cern.ch; Aguglia, D.; Andersson, P.; Bertolo, S.; Butterworth, A.; Coutron, Y.; Dallocchio, A.; David, N.; Chaudet, E.; Fink, D. A.; Garlasche, M.; Grudiev, A.; Guida, R.; Hansen, J.; Haase, M.; Jones, A.; Koszar, I.; Lallement, J.-B.; Lombardi, A. M.; Machado, C. [CERN-ABP, 1211 Geneva 23 (Switzerland); and others

    2016-02-15

    CERN’s 160 MeV H{sup −} linear accelerator (Linac4) is a key constituent of the injector chain upgrade of the Large Hadron Collider that is being installed and commissioned. A cesiated surface ion source prototype is being tested and has delivered a beam intensity of 45 mA within an emittance of 0.3 π ⋅ mm ⋅ mrad. The optimum ratio of the co-extracted electron- to ion-current is below 1 and the best production efficiency, defined as the ratio of the beam current to the 2 MHz RF-power transmitted to the plasma, reached 1.1 mA/kW. The H{sup −} source prototype and the first tests of the new ion source optics, electron-dump, and front end developed to minimize the beam emittance are presented. A temperature regulated magnetron H{sup −} source developed by the Brookhaven National Laboratory was built at CERN. The first tests of the magnetron operated at 0.8 Hz repetition rate are described.

  4. THE LINAC LASER NOTCHER FOR THE FERMILAB BOOSTER

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, David E, [Fermilab; Duel, Kevin [Fermilab; Gardner, Matthew [Fermilab; Johnson, Todd [Fermilab; Slimmer, David [Fermilab; Patil, Screenvias [PriTel, Inc; Tafoya, Jason [Optical Engines, Inc

    2016-09-27

    In synchrotron machines, the beam extraction is accomplished by a combination of septa and kicker magnets which deflect the beam from an accelerator into another. Ideally the kicker field must rise/fall in between the beam bunches. However, in reality, an intentional beam-free time region (aka "notch") is created on the beam pulse to assure that the beam can be extracted with minimal losses. In the case of the Fermilab Booster, the notch is created in the ring near injection energy by the use of fast kickers which deposit the beam in a shielded collimation region within the accelerator tunnel. With increasing beam power it is desirable to create this notch at the lowest possible energy to minimize activation. The Fermilab Proton Improvement Plan (PIP) initiated an R&D project to build a laser system to create the notch within a linac beam pulse at 750 keV. This talk will describe the concept for the laser notcher and discuss our current status, commissioning results, and future plans.

  5. Perifoveal interdigitation zone loss in hydroxychloroquine toxicity leads to subclinical bull's eye lesion appearance on near-infrared reflectance imaging.

    Science.gov (United States)

    Chew, Avenell L; Sampson, Danuta M; Chelva, Enid; Khan, Jane C; Chen, Fred K

    2017-11-09

    To characterize the ultrastructural and functional correlates of hydroxychloroquine (HCQ)-induced subclinical bull's eye lesion seen on near-infrared reflectance (NIR) imaging. An asymptomatic 54-year-old male taking HCQ presented with paracentral ring-like scotoma, abnormal multifocal electroretinography (mfERG) and preserved ellipsoid zone on optical coherence tomography (OCT). Dense raster OCT was performed to create en face reflectivity maps of the interdigitation zone. Macular Integrity Assessment (MAIA) microperimetry and mfERG findings were compared with NIR imaging, en face OCT, retinal thickness profiles and wave-guiding cone density maps derived from flood-illumination adaptive optics (AO) retinal photography. The bull's eye lesion is an oval annular zone of increased reflectivity on NIR with an outer diameter of 1450 µm. This region corresponds exactly to an area of preserved interdigitation zone reflectivity in en face OCT images and of normal cone density on AO imaging. Immediately surrounding the bull's eye lesion is an annular zone (3°-12° eccentricity) of depressed retinal sensitivity on MAIA and reduced amplitude density on mfERG. Wave-guiding cone density at 2° temporal was 25,400 per mm2. This declined rapidly to 12,900 and 1200 per mm2 at 3° and 4°. Multimodal imaging illustrated pathology in the area surrounding the NIR bull's eye, characterized by reduced reflectance, wave-guiding cone density and retinal function. Further studies are required to investigate whether the bull's eye on NIR imaging and en face OCT is prominent or consistent enough for diagnostic use.

  6. Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR-Linac.

    Science.gov (United States)

    Chen, Guang-Pei; Ahunbay, Ergun; Li, X Allen

    2016-04-01

    To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data are accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose-volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.

  7. Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR-Linac

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guang-Pei, E-mail: gpchen@mcw.edu; Ahunbay, Ergun; Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States)

    2016-04-15

    Purpose: To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. Methods: The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data are accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose–volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. Conclusions: The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.

  8. Abnormal dip phenomenon: a characteristic electrophysiological marker in interdigital neuropathy of the foot Fenômeno da diminuição de amplitude anormal: um marcador eletrofisiológico característico da neuropatia interdigital do pé

    Directory of Open Access Journals (Sweden)

    Diogo F. de Almeida

    2007-09-01

    Full Text Available OBJECTIVE: The nerve conduction findings in interdigital neuropathy of the foot (IDN; Morton's neuroma have rarely been reported. We analyzed the nerve conduction data in 23 patients with suspected IDN studied between 1982 and 2002. METHOD: Diagnosis of IDN was made on the basis of clinical features. All patients underwent routine nerve conduction studies and a near-nerve needle sensory nerve conduction study of the interdigital nerves by Oh's method in the symptomatic foot. RESULTS:Of the 23 patients, the diagnosis of definite IDN was made in 13 cases and of possible NDN in the others cases. Nineteen were females. Twenty two patients had only one nerve affected. One patient had two nerves affected. The III-IV interdigital nerve was affected in 17 cases and the II-III interdigital nerve in 7 cases. The near-nerve needle nerve conduction showed abnormality in the affected interdigital nerves in all definite IDN cases and confirmed the diagnosis of IDN in 10 cases by the abnormal dip phenomenon (a selective decrease of 50% or more in the sensory CNAP amplitude of the affected nerve compared with that of the preceding interdigital nerve. In 11 possible IDN cases, IDN was identified by the abnormal dip phenomenon. CONCLUSION: The near-nerve needle sensory nerve conduction of the interdigital nerves is a highly sensitive diagnostic test, and abnormal dip phenomenon is the most characteristic electrophysiological marker for the diagnosis of IDN.OBJETIVO: Os achados da condução nervosa na neuropatia interdigital do pé (NIP têm sido raramente descritos. Nós analisamos os dados da condução nervosa de 23 pacientes com suspeita de NIP entre 1982 e 2002. MÉTODO: O diagnóstico de NIP foi clínico. Todos os pacientes foram submetidos a estudos de condução nervosa de rotina e ao estudo de condução sensitiva dos nervos interdigitais com agulha justa-neural pelo método de Oh. RESULTADOS: Dos 23 pacientes, o diagnóstico de NIP foi definitivo em 13

  9. Summary of the Superconducting RF Linac for Muon Collider and Neutrino Factory

    CERN Document Server

    Galambos, J; Geer, S

    2011-01-01

    Project-X is a proposed project to be built at Fermi National Accelerator Laboratory with several potential missions. A primary part of the Project-X accelerator chain is a Superconducting linac, and In October 2009 a workshop was held to concentrate on the linac parameters. The charge of the workshop was to "..focus only on the SRF linac approaches and how it can be used...". The focus of Working Group 2 of this workshop was to evaluate how the different linac options being considered impact the potential realization of Muon Collider (MC) and Neutrino Factory (NF) applications. In particular the working group charge was, "to investigate the use of a multi-megawatt proton linac to target, phase rotate and collect muons to support a muon collider and neutrino factory". To focus the working group discussion, three primary questions were identified early on, to serve as a reference: 1) What are the proton source requirements for muon colliders and neutrino factories? 2) What are the issues with respect to realiz...

  10. 1974 view into the cage of the 520 keV electrostatic preaccelerator of Linac 1

    CERN Multimedia

    1974-01-01

    The condenser of the high voltage circuit (column in the foreground) is being serviced by Jean Luc Vallet. Standing on the electronics platform (the big, open metallic structure on insulating pillars, for details see 7403120) is Bob Nettelton. The column at the right edge of the photo is part of the bouncer (see also 7403066X) which compensated the voltage drop during acceleration of a proton pulse. In the background is the source (open pill box structure) attached to the accelerating column, barely visible) behind. The "old" 50 MeV Linac 1, the original PS injector built in the 1950s, was (since 1976) replaced by a new 50 MeV linac (Linac 2) with a 750 keV "Cockcroft-Walton" pre-injector(see 7602012X), later replaced by a 750 keV Radio Frequency Quadrupole (RFQ) preaccelerator. Linac 1 co-existed until mid 1992 (from 1982 onwards it was mainly used to inject "test-particles" into the Low Energy Antiproton ring LEAR). In 1984 the electrostatic preaccelerator of linac 1 was replaced by a 520 keV RFQ ( 8303511X...

  11. A general photon source model for clinical linac heads in photon mode

    Science.gov (United States)

    González, W.; García-Ferreira, I.-B.; Anguiano, M.; Lallena, A. M.

    2015-12-01

    In this work a general photon source model has been developed to describe clinical linac heads when operating in photon mode. Six different linacs (three operating at 6 MV, one at 15 MV and two at 18 MV) have been studied. The construction of the model as well as its validation have been carried out on the base of the virtual linac approach in which the complete linac geometries have been simulated with the Monte Carlo code PENELOPE. The model includes a primary and a secondary sources whose geometrical characteristics are determined from a set of simulated fluence distributions in air. The photon energy distributions are obtained from the Monte Carlo energy distributions of the photons moving along the beam axis, using a softening function that depends on the nominal energy of the beam and a Compton-like correction. To verify the model, output factors, percentage depth doses and transverse profiles in water obtained from a calculation performed with the complete geometry are compared to those found with the source model. A reasonable agreement is obtained in all cases analyzed except for the 18 MV Mevatron KDS linac for the 20 cm× 20 cm field.

  12. Updated layout of the LINAC4 transfer line to the PS Booster (Green Field Option)

    CERN Document Server

    Bellodi, G; Lallement, J B; Lombardi, A M; CERN. Geneva. AB Department

    2008-01-01

    At the time of defining the site of Linac4 and its integration in the complex of existing infrastructure at CERN (together with the plans for a future Superconducting Proton Linac), a series of radiation protection issues emerged that have since prompted a revision of the Linac4 to PSB transfer line layout, as was described in the document AB‐Note‐2007‐037. For radiological safety reasons the distance between the planned SPL tunnel and the basement of building 513 had to be increased, and this led to the decision to lower the Linac4 machine by 2.5m. A vertical ramp was consequently introduced in the transfer line to raise the beam at the same level of LINAC2/PSB for connection to the existing transfer line. A series of error study runs has been carried out on the modified layout to have an estimate of the losses induced by quadrupole alignment and field errors. The two worst cases of each error family have been used as case studies to test the efficiency of possible steering strategies in...

  13. Progress in the Design of the SPL, an $H ^{-}$ High-Intensity Linac at CERN

    CERN Document Server

    Bongardt, K; Frischholz, Hans; Gerigk, F; Lombardi, A M; Losito, R; Mostacci, A; Paoluzzi, M; Tückmantel, Joachim; Vretenar, Maurizio

    2002-01-01

    The SPL (Superconducting Proton Linac) is a 4 MW 2.2 GeV H- linac, intended to re-use most of the 352 MHz RF equipment from the decommissioned LEP machine. Injecting into the CERN PS, this linac would improve the intensity and quality of the CERN proton beams, while as a stand-alone facility could provide intense beams of radioactive ions or neutrinos (Neutrino Superbeam). Together with accumulator and compressor rings, it would be a suitable driver for a Neutrino Factory. Since the original proposal, many improvements to the design have been introduced, in order to simplify the layout and reduce costs. They include the reduction of the repetition frequency to 50 Hz, the design of a shorter superconducting (SC) linac section that goes up to the full energy with b=0.8 cavities, an improved DTL section including a new CCDTL design, a chopping line based on fast (2 ns rise time) low-voltage choppers and pulser, and a simplified front-end. Moreover, the problem of pulse mode operation of a superconducting linac w...

  14. Progress update on cryogenic system for ARIEL E-linac at TRIUMF

    Energy Technology Data Exchange (ETDEWEB)

    Koveshnikov, A.; Bylinskii, I.; Hodgson, G.; Yosifov, D. [TRIUMF, Vancouver, BC, V6T 2A3 (Canada)

    2014-01-29

    TRIUMF is involved in a major upgrade. The Advanced Rare IsotopeE Laboratory (ARIEL) has become a fully funded project in July 2010. A 10 mA 50 MeV SRF electron linac (e-linac) operating CW at 1.3 GHz is the key component of this initiative. This machine will serve as a second independent photo-fission driver for Rare Isotope Beams (RIB) production at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. The cryogens delivery system requirements are driven by the electron accelerator cryomodule design [1, 2]. Since commencement of the project in 2010 the cryogenic system of e-linac has moved from the conceptual design phase into engineering design and procurement stage. The present document summarizes the progress in cryogenic system development and construction. Current status of e-linac cryogenic system including details of LN{sub 2} storage and delivery systems, and helium subatmospheric (SA) system is presented. The first phase of e-linac consisting of two cryomodules, cryogens storage, delivery, and distribution systems, and a 600 W class liquid helium cryoplant is scheduled for installation and commissioning by year 2014.

  15. Feasibility of using the linac real-time log data for VMAT treatment verification

    Science.gov (United States)

    Midi, N. S.; Zin, Hafiz M.

    2017-05-01

    This study investigates the feasibility of using the real-time log data from a linac to verify Volumetric Modulated Arc Therapy (VMAT) treatment. The treatment log data for an Elekta Synergy linac can be recorded at a sampling rate of 4 Hz using the service graphing tool on the linac control computer. A treatment plan that simulates a VMAT treatment was delivered from the linac and all the dynamic treatment parameters including monitor unit (MU), Multileaf Collimator (MLC) position, jaw position, gantry angle and collimator angle were recorded in real-time using the service graphing tool. The recorded raw data were extracted and analysed using algorithms written in Matlab (MathWorks, Natick, MA). The actual treatment parameters logged using the service graphing tool was compared to the prescription and the deviations were analysed. The MLC position errors travelling at the speed range from -3.25 to 5.92 cm/s were between -1.7 mm to 2.5 mm, well within the 3.5 mm tolerance value (AAPM TG-142). The discrepancies of other delivery parameters were also within the tolerance. The real-time linac parameters logged using the service graphing tool can be used as a supplementary data for patient specific VMAT pre-treatment quality assurance.

  16. Design of a 10 MeV normal conducting CW proton linac based on equidistant multi-gap CH cavities

    Science.gov (United States)

    Li, Zhi-Hui

    2015-09-01

    Continuous wave (CW) high current proton linacs have wide applications as the front end of high power proton machines. The low energy part of such a linac is the most difficult and there is currently no widely accepted solution. Based on the analysis of the focusing properties of the CW low energy proton linac, a 10 MeV low energy normal conducting proton linac based on equidistant seven-gap Cross-bar H-type (CH) cavities is proposed. The linac is composed of ten 7-gap CH cavities and the transverse focusing is maintained by quadrupole doublets located between the cavities. The total length of the linac is less than 6 meters and the average acceleration gradient is about 1.2 MeV/m. The electromagnetic properties of the cavities are investigated by Microwave Studio. At the nominal acceleration gradient the maximum surface electric field in the cavities is less than 1.3 times the Kilpatrick limit, and the Ohmic loss of each cavity is less than 35 kW. Multi-particle beam dynamics simulations are performed with Tracewin code, and the results show that the beam dynamics of the linac are quite stable, the linac has the capability to accelerate up to 30 mA beam with acceptable dynamics behavior. Supported by National Natural Science Foundation of China (11375122, 91126003)

  17. Calibration of the High Resolution Phase Shifter (HRPS) in Linac 3/Rex using a dedicated LabView program

    CERN Document Server

    Winsvold, D

    2013-01-01

    This is a document describing how to calibrate the High Resolution Phase Shifters of Linac 3 and REX. The document also describes how to do tests on the Delay Lines in Linac 2, 3 and REX, but these cannot be calibrated.

  18. Predictive time-series modeling using artificial neural networks for Linac beam symmetry: an empirical study.

    Science.gov (United States)

    Li, Qiongge; Chan, Maria F

    2017-01-01

    Over half of cancer patients receive radiotherapy (RT) as partial or full cancer treatment. Daily quality assurance (QA) of RT in cancer treatment closely monitors the performance of the medical linear accelerator (Linac) and is critical for continuous improvement of patient safety and quality of care. Cumulative longitudinal QA measurements are valuable for understanding the behavior of the Linac and allow physicists to identify trends in the output and take preventive actions. In this study, artificial neural networks (ANNs) and autoregressive moving average (ARMA) time-series prediction modeling techniques were both applied to 5-year daily Linac QA data. Verification tests and other evaluations were then performed for all models. Preliminary results showed that ANN time-series predictive modeling has more advantages over ARMA techniques for accurate and effective applicability in the dosimetry and QA field. © 2016 New York Academy of Sciences.

  19. Induced radioisotopes inside the treatment hall with a Linac for radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    De Leon M, H. A. [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., Fracc. Bona Gens, 20255 Aguascalientes (Mexico); Rivera P, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A., E-mail: asa_15@hotmail.com [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain)

    2014-08-15

    When Linacs operate above 8 MV an undesirable neutron field is produced whose spectrum has three main components: the direct spectrum due to those neutrons leaking out from the Linac head, the scattered spectrum due to neutrons produced in the head that collides with the nuclei in the head losing energy and the third spectrum due to room-return effect; this last are mainly epithermal and thermal neutrons being constant at any location in the treatment hall. These neutrons induce activation mainly in the concrete walls and the Linac components. Here the induced radioisotopes have been identified in concrete samples located in the hall and in one of the wedges. The identification has been carried out using a gamma-ray spectrometer. (Author)

  20. Conceptual study of high power proton linac for accelerator driven subcritical nuclear power system

    CERN Document Server

    Yu Qi; Ouyang Hua Fu; Xu Tao Guang

    2001-01-01

    As a prior option of the next generation of energy source, the accelerator driven subcritical nuclear power system (ADS) can use efficiently the uranium and thorium resource, transmute the high-level long-lived radioactive wastes and raise nuclear safety. The ADS accelerator should provide the proton beam with tens megawatts. The superconducting linac is a good selection of ADS accelerator because of its high efficiency and low beam loss rate. The ADS accelerator presented by the consists of a 5 MeV radio-frequency quadrupole, a 100 MeV independently phased superconducting cavity linac and a 1 GeV elliptical superconducting cavity linac. The accelerating structures and main parameters are determined and the research and development plan is considered

  1. A CONCEPTUAL 3-GEV LANSCE LINAC UPGRADE FOR ENHANCED PROTON RADIOGRAPHY

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, Robert W [Los Alamos National Laboratory; Rybarcyk, Lawrence J. [Los Alamos National Laboratory; Merrill, Frank E. [Los Alamos National Laboratory; O' Hara, James F. [Los Alamos National Laboratory; Rees, Daniel E. [Los Alamos National Laboratory; Walstrom, Peter L. [Los Alamos National Laboratory

    2012-05-14

    A conceptual design of a 3-GeV linac upgrade that would enable enhanced proton radiography at the Los Alamos Neutron Science Center (LANSCE) is presented. The upgrade is based on the use of superconducting accelerating cavities to increase the present LANSCE linac output energy from 800 MeV to 3 GeV. The LANSCE linac currently provides negative hydrogen ion (H{sup -}) and proton (H{sup +}) beams to several user facilities that support Isotope Production, NNSA Stockpile Stewardship, and Basic Energy Science programs. Required changes to the front-end, the accelerating structures, and to the RF systems to meet the new performance goals, and changes to the existing beam switchyard to maintain operations for a robust user program are also described.

  2. Commissioning of the CERN LINAC4 BPM System with 50 Mev Proton Beamns

    CERN Document Server

    Tan, J; Søby, L; Sordet, M; Wendt, M

    2013-01-01

    The new Linac4 at CERN will provide a 160 MeV H- ion beam for charge-exchange injection into the existing CERN accelerator complex. Shorted stripline pick-ups placed in the Linac intertank regions and the transfer lines will measure beam orbit, relative beam current, beam phase, and average beam energy via the time-of-flight between two pickups. A prototype Beam Position Monitor (BPM) system has been installed in the transfer line between the existing Linac2 and the Proton Synchrotron Booster (PSB) in order to study and review the complete acquisition chain. This paper presents measurements and performance of this BPM system operating with 50 MeV proton beams, and compares the results with laboratory measurements and electromagnetic simulations.

  3. BEAM DYNAMICS STUDIES FOR A COMPACT CARBON ION LINAC FOR THERAPY

    Energy Technology Data Exchange (ETDEWEB)

    Plastun, A.; Mustapha, B.; Nassiri, A.; Ostroumov, P.

    2016-05-01

    Feasibility of an Advanced Compact Carbon Ion Linac (ACCIL) for hadron therapy is being studied at Argonne National Laboratory in collaboration with RadiaBeam Technologies. The 45-meter long linac is designed to deliver 109 carbon ions per second with variable energy from 45 MeV/u to 450 MeV/u. S-band structure provides the acceleration in this range. The carbon beam energy can be adjusted from pulse to pulse, making 3D tumor scanning straightforward and fast. Front end accelerating structures such as RFQ, DTL and coupled DTL are designed to operate at lower frequencies. The design of the linac was accompanied with extensive end-to-end beam dynamics studies which are presented in this paper.

  4. Analysis of the microbunching instability in a mid-energy electron linac

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Da-Zhang; Gu, Qiang; Wang, Zhen; Zhang, Meng; Ng, King Yuen

    2015-03-01

    Microbunching instability usually exists in the linear accelerator (linac) of a free electron laser (FEL) facility. If it is not controlled effectively, the beam quality will be damaged seriously and the machine will not operate properly. In the electron linac of a soft X-ray FEL device, because the electron energy is not very high, the problem can become even more serious. As a typical example, the microbunching instability in the linac of the proposed Shanghai Soft X-ray Free Electron Laser facility (SXFEL) is investigated in detail by means of both analytical formulae and simulation tools. In the study, a new mechanism introducing random noise into the beam current profile as the beam passes through a chicane-type bunch compressor is proposed. The higher-order modes that appear in the simulations suggest that further improvement of the current theoretical model of the instability is needed.

  5. First commissioning experience with the LINAC4 3 MeV front-end at CERN

    CERN Document Server

    Lallement, J B; Bellodi, G; Comblin, J F; Dimov, V A; Granemann Souza, E; Lettry, J; Lombardi, A M; Midttun, O; Ovalle, E; Raich, U; Roncarolo, F; Rossi, C; Sanchez Alvarez, R; Scrivens, C A; Valerio-Lizarraga, C A; Vretenar, M; Yarmohammadi Satri, M

    2013-01-01

    Linac4 is a normal-conducting 160 MeV H- linear accelerator presently under construction at CERN. It will replace the present 50 MeV Linac2 as injector of the proton accelerator complex as part of a project to increase the LHC luminosity. The Linac front-end, composed of a 45 keV ion source, a Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) housing a beam chopper, have been commissioned at the 3 MeV test stand during the first half of 2013. The status of the installation and the results of the first commissioning stage are presented in this paper.

  6. Effect of H- stripped electrons on the LINAC4 profile measurements

    CERN Document Server

    Chevallay, E; Duraffourg, M; Focker, GJ; Hessler, C; Raich, U; Roncarolo, F; Vuitton, C; Zocca, F

    2013-01-01

    At CERN's LINAC4 it is foreseen to measure transverse beam profiles by means of Secondary Emission wire grids (normally referred to as SEM monitors or SEM grids) and Beam Wire Scanners (BWS). Following observations at the SNS linac BWS, that showed cross-talk between wire signals attributed to scattering of H- stripped electrons, it was decided to investigate this effect for the LINAC4 case. The interaction of electron beams with Carbon and Tungsten wires was studied through Monte Carlo simulations (FLUKA code), analytical calculations, particle tracking simulations in EM fields (CST Particle Studio) and a laboratory experiment based on a 70 keV electron beam, well reproducing the case of 128 MeV H- ions.

  7. Multi-cell disk-and-ring tapered structure for compact RF linacs

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, A.V.; Boucher, S.; Kutsaev, S. [RadiaBeam Systems LLC, 1713 Stewart Street, Santa Monica, CA 90404, US (United States); Hartzell, J. [RadiaBeam Technologies, LLC, 1717 Stewart Street, Santa Monica, CA 90404, US (United States); Savin, E. [RadiaBeam Technologies, LLC, 1717 Stewart Street, Santa Monica, CA 90404, US (United States); National Research Nuclear University “MEPhI”, Moscow 115409 (Russian Federation)

    2016-09-11

    A tubular disk-and-ring, tapered accelerating structure for small electron linacs and MicroLinacs is considered. It consists of metal and dielectric elements inserted into a metallic tube to eliminate multi-cell, multi-step brazing. The structure enables a wide range of phase velocities (including non-relativistic), a wide bandwidth allowing large number of cells (for standing wave mode) or short filling time (for traveling wave mode), combination of compensated and purely π-mode cells, alternative periodic focusing built-in to the RF structure (the disks), and combining of RF and vacuum windows. RF and accelerating performance of such a long structure having up to four dozens cells is analyzed. Some of beam dynamics, thermal, and vacuum aspects of the structure and MicroLinac performance are considered as well.

  8. An electron front end for the Fermilab multi-species 8 GeV SCRF linac

    Energy Technology Data Exchange (ETDEWEB)

    Philippe R.-G. Piot; G W Foster

    2004-07-08

    Fermilab is considering a 8 GeV superconducting linac whose primary mission is to serve as an intense H{sup -} injector for the main injector. This accelerator is also planned to be used for accelerating various other species (e.g. electrons, protons and muons). In the present paper we investigate the possibility of such a linac to accelerate high-brightness electron beam up to {approx} 7 GeV. We propose a design for the electron front end based on a photoinjector and consider the electron beam dynamics along the linac. Start-to-end simulations of the full accelerator for electrons are presented. Finally the potential applications of such an electron beam are outlined.

  9. Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

    Science.gov (United States)

    Howell, Rebecca M; Kry, Stephen F; Burgett, Eric; Hertel, Nolan E; Followill, David S

    2009-09-01

    Neutrons are a by-product of high-energy x-ray radiation therapy (threshold for [gamma,n] reactions in high-Z material -7 MeV). Neutron production varies depending on photon beam energy as well as on the manufacturer of the accelerator. Neutron production from modern linear accelerators (linacs) has not been extensively compared, particularly in terms of the differences in the strategies that various manufacturers have used to implement multileaf collimators (MLCs) into their linac designs. However, such information is necessary to determine neutron dose equivalents for different linacs and to calculate vault shielding requirements. The purpose of the current study, therefore, was to measure the neutron spectra from the most up-to-date linacs from three manufacturers: Varian 21EX operating at 15, 18, and 20 MV, Siemens ONCOR operating at 15 and 18 MV, and Elekta Precise operating at 15 and 18 MV. Neutron production was measured by means of gold foil activation in Bonner spheres. Based on the measurements, the authors determined neutron spectra and calculated the average energy, total neutron fluence, ambient dose equivalent, and neutron source strength. The shapes of the neutron spectra did not change significantly between accelerators or even as a function of treatment energy. However, the neutron fluence, and therefore the ambient dose equivalent, did vary, increasing with increasing treatment energy. For a given nominal treatment energy, these values were always highest for the Varian linac. The current study thus offers medical physicists extensive information about the neutron production of MLC-equipped linacs currently in operation and provides them information vital for accurate comparison and prediction of neutron dose equivalents and calculation of vault shielding requirements.

  10. RF control at transient beamloading for high-duty-factor linacs

    Energy Technology Data Exchange (ETDEWEB)

    Chernogubovsky, M.A.; Sugimoto, Masayoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-08-01

    An effective RF control with the transient beamloading is the major issue in the operation of the high-duty-factor linacs to suppress the undesirable beam loss. The RF control method is considered to obtain the control principle and the state equation, under the analysis of electrodynamical properties of the excitation in the resonator of the linac due to the transient beamloading. The concept of the directional selective coupling is applied for the RF system to define the main characteristics and to optimize the RF control parameters. (author)

  11. Results of a High-Power Klystron Dip Test in the KEK Linac

    CERN Document Server

    Nakao, Katsumi; Katagiri, Hiroaki; Matsumoto, Toshihiro; Michizono, Shinichiro; Takenaka, Tateru; Yano, Yoshiharu; Yoshida, Mitsuhiro

    2005-01-01

    Dip test, which is the measurement of a klystron heater activity, is recently adopted as the standard measurement to maintain the klystron operation in the KEK electron-positron linac. In 2003, we began to use a dip test as the quick way to measure the emission characteristics from the klystron cathode. After the successful results, we made the dedicated measuring systems and measured the dips of the cathode emission of 60 operating klystrons in KEK electron-positron linac. These data are important to estimate the klystron cathode life and used to select the candidate klystrons of replacement in the summer maintenance period.

  12. Validation of Monte-Carlo Geant4 code for Saturne 43 LINAC

    OpenAIRE

    J. EL Bakkali; El Bardouni, T.; M. Zoubair; H. Boukhal

    2013-01-01

    The aim of this study was to model the 12 MV photon beam from a Saturne 43 LINAC configuring a 10×10 cm2 radiation field, this by finding the required adjustments to the electron source parameters namely the spot size, shape and energy distribution. The MC simulation tool Geant4 version 4.9.4 was used with rocks clustering software and Geant4 MPI Interface to parallelize our Geant4-based application. In this work, we have developed a user code for Saturne 43 LINAC simulation. This code has th...

  13. CTF3 Probe Beam LINAC Commissioning and Operations

    CERN Document Server

    Farabolini, W; Curtoni, A; Girardot, P; Peauger, F; Simon, C S; Chevallay, E; Divall Csatari, M; Lebas, N; Petrarca, M; Palaia, A; Ruber, R J M Y; Ziemann, V G

    2010-01-01

    The probe beam LINAC, CAL­IFES, of the CLIC Test Fa­cil­i­ty (CTF3) has been de­vel­oped by CEA Saclay, LAL Orsay and CERN to de­liv­er trains of short bunch­es (0.75 ps) spaced by 0.666 ps at an en­er­gy around 170 MeV with a charge of 0.6 nC to the TBTS (Two-beam Test Stand) in­tend­ed to test the high gra­di­ent CLIC ac­cel­er­at­ing struc­tures. Based on 3 for­mer LIL ac­cel­er­at­ing struc­tures and on a newly de­vel­oped RF pho­to-in­jec­tor, the whole ac­cel­er­a­tor is pow­ered with a sin­gle 3 GHz klystron de­liv­er­ing puls­es of 45 MW through a RF pulse com­pres­sion cav­i­ty and a net­work of waveg­uides, split­ters, phase-shifters and an at­ten­u­a­tor. We re­late here re­sults col­lect­ed dur­ing the var­i­ous com­mis­sion­ing and op­er­a­tion pe­ri­ods which led to nom­i­nal per­for­mances and sta­ble beam char­ac­ter­is­tics de­liv­ered to the TBTS. Progress has been made in the laser sys­tem for beam charge and sta...

  14. Ozonized autohemotherapy, a new method to treat dairy cow acute interdigital phlegmon. Comparison with ceftiofur and oxytetracycline

    Directory of Open Access Journals (Sweden)

    Bruno Pogliacani

    2010-01-01

    Full Text Available To determine whether ozone (a powerful germicidal agent administered by autohemotherapy would be useful for treat-  ment of acute interdigital phlegmon (foot rot in dairy cows, 60 animals affected by clinical signs of foot rot were used  in this trial. Twenty dairy cows were assigned to one of the three treatment groups: ceftiour sodium 1.0 mg/kg Body  Weight (B.W. i.v. every 12 h; oxytetracycline 6.0 mg/kg B.W. i.v. every 24 h; ozone 60 mg in 1000 ml of blood by i.v.  autohemotherapy every 24 h. Treatments stopped when animals were no longer lame. All the lameness stopped after  three days of ceftiour treatment, three days of oxytetracycline treatment and one day of ozone autohemotherapy treat-  ment. Use of ozone in autohemotherapy for dairy cow foot rot was as effective as ceftiour and oxytetracycline treatments,  and resulted to be the best one because milk and meat obtained from dairy cows treated with ozone were not subject to  withdrawal time. 

  15. Real-time monitoring of strand-displacement DNA amplification by a contactless electrochemical microsystem using interdigitated electrodes.

    Science.gov (United States)

    Fang, Xinxin; Zhang, Huanqian; Zhang, Feng; Jing, Fengxiang; Mao, Hongju; Jin, Qinghui; Zhao, Jianlong

    2012-09-07

    This paper reports the design and implementation of a contactless conductivity detection system which combines a thermal control cell, a data processing system and an electrochemical (EC) cell for label-free isothermal nucleic acid amplification and real-time monitoring. The EC cell consists of a microchamber and interdigitated electrodes as the contactless conductivity biosensor with a cover slip as insulation. In our work, contactless EC measurements, the effects of trehalose on amplification, and chip surface treatment are investigated. With the superior performance of the biosensor, the device can detect the amount of pure DNA at concentrations less than 0.1 pg μl(-1). The EC cell, integrated with a heater and a temperature sensor, has successfully implemented nicking-based strand-displacement amplification at an initial concentration of 2.5 μM and the yields are monitored directly (dismissing the use of probes or labels) on-line. This contactless detector carries important advantages: high anti-interference capability, long detector life, high reusability and low cost. In addition, the small size, low power consumption and portability of the detection cell give the system the potential to be highly integrated for use in field service and point of care applications.

  16. Incorporating the Thiazolo[5,4-d]thiazole Unit into a Coordination Polymer with Interdigitated Structure

    Directory of Open Access Journals (Sweden)

    Simon Millan

    2018-01-01

    Full Text Available The linker 2,5-di(4-pyridylthiazolo[5,4-d]thiazole (Dptztz, whose synthesis and structure is described here, was utilized together with benzene-1,3-dicarboxylate (isophthalate, 1,3-BDC2− for the preparation of the two-dimensional coordination network [Zn(1,3-BDCDptztz]·DMF (DMF = dimethylformamide via a solvothermal reaction. Compound [Zn(1,3-BDCDptztz]·DMF belongs to the class of coordination polymers with interdigitated structure (CIDs. The incorporated DMF solvent molecules can be removed through solvent exchange and evacuation such that the supramolecular 3D packing of the 2D networks retains porosity for CO2 adsorption in activated [Zn(1,3-BDCDptztz]. The first sorption study of a tztz-functionalized porous metal-organic framework material yields a BET surface of 417 m2/g calculated from the CO2 adsorption data. The heat of adsorption for CO2 exhibits a relative maximum with 27.7 kJ/mol at an adsorbed CO2 amount of about 4 cm3/g STP, which is interpreted as a gate-opening effect.

  17. Integrated titanium dioxide (TiO{sub 2}) nanoparticles on interdigitated device electrodes (IDEs) for pH analysis

    Energy Technology Data Exchange (ETDEWEB)

    Azizah, N., E-mail: norazizahparmin84@gmail.com; Gopinath, Subash C. B.; Nadzirah, Sh.; Farehanim, M. A.; Fatin, M. F.; Ruslinda, A. R. [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP) Kangar, Perlis (Malaysia); Hashim, U., E-mail: uda@unimap.edu.my; Arshad, M. K. Md.; Ayub, R. M. [Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP) Kangar, Perlis (Malaysia); School of Microelectronic Engineering Universiti Malaysia Perlis (UniMAP) Kangar, Perlis (Malaysia)

    2016-07-06

    Titanium dioxide (TiO{sub 2}) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO{sub 2} was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to an acid solution. Amine and oxide functionalized TiO{sub 2} based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO{sub 2} based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO{sub 2} based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.

  18. Characterization of Piezoresistive PEDOT:PSS Pressure Sensors with Inter-Digitated and Cross-Point Electrode Structures

    Directory of Open Access Journals (Sweden)

    Jer-Chyi Wang

    2015-01-01

    Full Text Available The piezoresistive characteristics of poly(3,4-ethylenedioxythiophene:polystyrene sulfonate (PEDOT:PSS pressure sensors with inter-digitated (IDE and cross-point electrode (CPE structures have been investigated. A small variation of the resistance of the pressure sensors with IDE without bottom indium-tin-oxide (b-ITO film and with CPE structures was observed owing to the single carrier-conducting pathway. For the IDE pressure sensors with b-ITO, the piezoresistive characteristics at low and high pressure were similar to those of the pressure sensors with IDE without b-ITO and with CPE structures, respectively, leading to increased piezoresistive pressure sensitivity as the PEDOT:PSS film thickness decreased. A maximum sensitivity of more than 42 kΩ/Pa was achieved. When the normal pressure was applied, the increased number of conducting points or the reduced distance between the PEDOT oligomers within the PEDOT:PSS film resulted in a decrease of the resistance. The piezoresistive pressure sensors with a single carrier-conducting pathway, i.e., IDE without b-ITO and CPE structures, exhibited a small relaxation time and a superior reversible operation, which can be advantageous for fast piezoresistive response applications.

  19. Impedance spectral fingerprint of E. coli cells on interdigitated electrodes: A new approach for label free and selective detection

    Directory of Open Access Journals (Sweden)

    Maria Mallén-Alberdi

    2016-03-01

    Full Text Available Impedance-based biosensors for bacterial detection offer a rapid and cost-effective alternative to conventional techniques that are time-consuming and require specialized equipment and trained users. In this work, a new bacteria detection scheme is presented based on impedance measurements with antibody-modified polysilicon interdigitated electrodes (3 μm pitch, IDEs. The detection approach was carried out taking advantage of the E. coli structure which, in electrical terms, is constituted by two insulating cell membranes that separate a conductive cytoplasmatic medium and a more conductive periplasm. Impedance detection of bacteria is usually analyzed using electrical equivalent circuit models that show limitations for the interpretation of such complex cell structure. Here, a differential impedance spectrum representation is used to study the unique fingerprint that arises when bacteria attach to the surface of IDEs. That fingerprint shows the dual electrical behavior, insulating and conductive, at different frequency ranges. In parallel, finite-element simulations of this system using a three-shell bacteria model are performed to explain such phenomena. Overall, a new approach to detect bacteria is proposed that also enables to differentiate viable bacteria from other components non-specifically attached to the IDE surface by just detecting their spectral fingerprints.

  20. Low concentration of DMSO stabilizes the bilayer gel phase rather than the interdigitated gel phase in dihexadecylphosphatidylcholine membrane.

    Science.gov (United States)

    Yamashita, Y; Kinoshita, K; Yamazaki, M

    2000-08-25

    We have investigated effects of dimethylsulfoxide (DMSO) on the phase stability of multilamellar vesicles of the ether-linked 1,2-dihexadecyl-sn-glycero-3-phosphatidylcholine (DHPC-MLV), which is known to be in the interdigitated gel (LbetaI) phase in excess water at 20 degrees C. The results of X-ray diffraction experiments indicate that the DHPC membrane was in the Lbeta, phase at X> or =0.12 (X=mole fraction of DMSO in DMSO/water mixture). The result of differential scanning calorimetry indicate that the gel to liquid-crystalline phase transition temperature increased, but the LbetaI to Pbeta, phase transition temperature decreased with an increase in DMSO concentration. These results show that DMSO stabilizes the bilayer gel phase rather than the LbetaI phase at its low concentration. The solubility of phosphorylcholine, which is the same structure as the headgroup of DHPC, decreased with an increase in DMSO concentration, indicating that the interaction free energy of the hydrophilic segments of the membrane with solvents increases with an increase in DMSO concentration. On the basis of the thermodynamic analysis, the mechanism of the stabilization of the bilayer gel phase of DHPC-MLV by DMSO is discussed. The decrease in the repulsive interaction between the headgroups of the phospholipid induced by the low concentrations of DMSO in water plays an important role in this stabilization.

  1. Interdigitated-electrode-based MEMS-scale piezoelectric energy harvester modeling and optimization using finite element method.

    Science.gov (United States)

    Toprak, Alperen; Tigli, Onur

    2013-10-01

    This paper presents a novel optimization method for interdigitated electrode (IDE)-based, cantilever-type piezoelectric energy harvesters at microelectromechanical system (MEMS) scale. A new two-stage approach based on the finite element method is proposed to examine the performance of such devices. First, detailed electrostatic poling simulations are presented. The results of these poling orientation simulations are used while calculating electrical energy and conversion efficiency in response to a constant external force. The proposed approach is used to find the optimum piezoelectric material thickness and IDE geometry for a cantilever beam which is constructed on top of a 4-μm Si structural layer and a 1-μm SiO2 isolation layer. Cantilever and IDE lengths are fixed at 320 μm and 240 μm, respectively, whereas the lead zirconate titanate (PZT) thickness, IDE finger widths, and number of finger pairs are varied. Maximum output energy of 0.37 pJ for a 15-μN force is obtained at a PZT thickness of 0.6 μm and an IDE consisting of 12 finger pairs. This energy is reduced to 1.5 fJ for 5 μm PZT thickness with 2 electrode finger pairs, which shows that device geometry has a significant impact on device performance. The proposed method presents an accurate framework for the rapid design and performance prediction of novel piezoelectric energy harvester structures.

  2. Beam Effects from an Increase of LINAC Current from 40 ma to 49 Milliamperes

    Energy Technology Data Exchange (ETDEWEB)

    Ray Tomlin

    2002-06-05

    On March 25, 2002 the FNAL Linac had been running at a decreased 40 ma of beam current for some time. Both the 400 MeV Linac and the 8GeV Booster had been tuned to optimum running during that time. Optimum running for the Booster was at 4.1e12 per pulse. Losses at injection and at transition were limiting intensity at the time. By March 26, 2002 the Linac beam current had been increased to 49 ma. The optimum Booster intensity immediately jumped to 4.5e12 per pulse and increased in the next few days to 4.8e12 and 5e12 per pulse. Booster was not retuned until early April when a low-loss 5.0e12 was obtained for stacking operations. Linac current had sagged to 47 ma by then. Measurements were made on the 25th at 40 ma and the 26th and 27th at 49 ma. This is a report and discussion of those measurements.

  3. A new methodology for inter- and intrafraction plan adaptation for the MR-linac

    NARCIS (Netherlands)

    Kontaxis, C|info:eu-repo/dai/nl/413754162; Bol, G H|info:eu-repo/dai/nl/343084309; Lagendijk, J J W|info:eu-repo/dai/nl/07011868X; Raaymakers, B W|info:eu-repo/dai/nl/229639410

    2015-01-01

    The new era of hybrid MRI and linear accelerator machines, including the MR-linac currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to provide the actual anatomy and real-time anatomy changes of the patient's target(s) and organ(s) at risk

  4. Amplitude model for beam oscillations in the main Linac of CLIC

    CERN Document Server

    Pfingstner, Jürgen; Schmickler, Hermann; Hofbaur, Michael

    2010-01-01

    To achieve the challenging goal of ultra-low emittance preservation in the main linac of CLIC, different techniques are used. The according algorithms often rely on an accurate, fast and efficient to compute model of the amplitude behavior of the beam oscillations in the beam line. In this paper such a model is developed, considering the accelerator design as well as the effect of filamentation. Filamentation is especially important, due to the high energy spread of the according beam and the large total phase advance of the lattice. Therefore a general model to describe filamentation is adapted to the properties of the beam in the main linac of CLIC. At the beginning of the linac, where made assumptions are not valid, this basic model is supported by a fit to simulation data. An accuracy evaluation of the produced data shows that the quadratic error is around 4 %. Therefore, the developed model delivers a fast and efficient procedure, to precisely predict the beam envelope behavior in the main linac of CLIC.

  5. High duty factor Plasma Generator for CERN’s Superconducting Proton Linac

    CERN Document Server

    Lettry, J; Scrivens, R; Chaudet, E; Faircloth, D; Favre, G; Geisser, JM; Kuchler, D; Mathot, S; Midttun, O; Paoluzzi, M; Schmitzer, C; Steyaert, D

    2010-01-01

    CERN’s Linac4 is a 160 MeV linear accelerator currently under construction. It will inject negatively charged hydrogen ions into CERN’s PS-Booster. Its ion source is a non-cesiated RF driven H- volume source directly inspired from the one of DESY and is aimed to deliver pulses of 80 mA of H- during 0.4 ms at a 2 Hz repetition rate. The Superconducting Proton Linac (SPL) project is part of the luminosity upgrade of the LHC, it consists of an extension of Linac4 up to 5 GeV and is foreseen to deliver protons to a future 50 GeV Synchrotron (PS2). For the SPL high power option (HP-SPL), the ion source would deliver pulses of 80 mA of H- during 1.2 ms and operate at a 50 Hz repetition rate. This significant upgrade motivates the design of the new water cooled plasma generator presented in this paper. Its engineering is based on the results of a finite element thermal study of the Linac4 H- plasma generator that identified critical components and thermal barriers. A cooling system is proposed which achieves the...

  6. A microcosting study of microsurgery, LINAC radiosurgery, and gamma knife radiosurgery in meningioma patients

    NARCIS (Netherlands)

    S.S. Tan (Siok Swan); A.E. van Putten (Anne); W.M. Nijdam (Wideke); P. Hanssens (Patrick); G.N. Beute (Guus); P.J.C.M. Nowak (Peter); C.M.F. Dirven (Clemens); L. van Hakkaart-van Roijen (Leona)

    2011-01-01

    textabstractThe aim of the present study is to determine and compare initial treatment costs of microsurgery, linear accelerator (LINAC) radiosurgery, and gamma knife radiosurgery in meningioma patients. Additionally, the follow-up costs in the first year after initial treatment were assessed. Cost

  7. Modeling radiation loads in the ILC main linac and a novel approach to treat dark current

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, Nilolai V. [Fermilab; Rakhno, Igor L. [Fermilab; Tropin, Igor S. [Fermilab

    2017-09-11

    Electromagnetic and hadron showers generated by electrons of dark current (DC) can represent a significant radiation threat to the ILC linac equipment and personnel. In this study, a commissioning scenario is analysed which is considered as the worst-case scenario for the main linac regarding the DC contribution to the radiation environment in the tunnel. A normal operation scenario is analysed as well. An emphasis is made on radiation load to sensitive electronic equipment—cryogenic thermometers inside the cryomodules. Prompt and residual dose rates in the ILC main linac tunnels were also calculated in these new high-statistics runs. A novel approach was developed—as a part of general purpose Monte Carlo code MARS15—to model generation, acceleration and transport of DC electrons in electromagnetic fields inside SRF cavities. Comparisons were made with a standard approach when a set of pre-calculated DC electron trajectories is used, with a proper normalization, as a source for Monte Carlo modelling. Results of MARS15 Monte Carlo calculations, performed for the current main linac tunnel design, reveal that the peak absorbed dose in the cryogenic thermometers in the main tunnel for 20 years of operation is about 0.8 MGy. The calculated contact residual dose on cryomodules and tunnel walls in the main tunnel for typical irradiation and cooling conditions is 0.1 and 0.01 mSv/hr, respectively.

  8. Progress in the design of the SPL, an $H^{-}$ high-intensity linac at CERN

    CERN Document Server

    Bongardt, K; Frischholz, Hans; Garoby, R; Gerigk, F; Lombardi, A M; Losito, R; Mostacci, A; Paoluzzi, M; Tückmantel, Joachim; Vretenar, Maurizio

    2002-01-01

    The SPL (Superconducting Proton Linac) is a 4 MW 2.2 GeV H/sup -/ linac, intended to reuse most of the 352 MHz RF equipment from the decommissioned LEP machine. Injecting into the CERN PS, this linac would improve the intensity and quality of the CERN proton beams, while as a stand-alone facility could provide intense beams of radioactive ions or neutrinos (Neutrino Superbeam). Together with accumulator and compressor rings, it would be a suitable driver for a Neutrino Factory. Since the original proposal, many improvements to the design have been introduced, in order to simplify the layout and reduce costs. They include the reduction of the repetition frequency to 50 Hz, the design of a shorter superconducting (SC) linac section that goes up to the full energy with beta =0.8 cavities, an improved DTL section including a new CCDTL design, a chopping line based on fast (2 ns rise time) low-voltage choppers and pulser, and a simplified front-end. Moreover, the problem of pulse mode operation of a superconductin...

  9. The new building for Linac4 is ready ahead of schedule

    CERN Multimedia

    Francesco Poppi

    2010-01-01

    When various teams work together efficiently to achieve a common goal, not only are projects successfully completed but they may ever be ready before the deadline. On 22 October, after two years of civil engineering work and about two months ahead of schedule, the building that will host the new Linac4 was unveiled in the presence of the Director-General and of Steve Myers, Director for Accelerators and Technology.   Entrance to new Linac 4 tunnel. For the time being, the new two-storey 3000 m2 building looks like a huge empty hangar. Very soon, though, the ground floor will start to be filled with the technical equipment and the klystrons. The Linac4 itself will be installed in the tunnel excavated below the ground. “Being 12 metres underground, deep inside what remains of the old “Mount Citron”, the tunnel provides excellent shielding for the new accelerator”, says Maurizio Vretenar, Linac4 Project Leader. The tunnel will be connected to the PS Booster...

  10. Recent results from digital INGA at BARC–TIFR Pelletron Linac ...

    Indian Academy of Sciences (India)

    2014-11-01

    Nov 1, 2014 ... An experimental campaign aimed at studying various high spin phenomena using the Indian National Gamma Array (INGA) at the BARC–TIFR Pelletron Linac Facility has been successfully completed. The array consisting of a large number of Compton-suppressed clover detectors was coupled to a digital ...

  11. Design of the Pi-Mode Structure (PIMS) for Linac4

    CERN Document Server

    Gerigk, F

    2010-01-01

    The PIMS will accelerate an H| − | beam from 100 MeV to 160 MeV, the output energy of Linac4. The cell length is constant within each of the 12 seven-cell cavities, but increases from cavity to cavity according to the increasing beam velocity. Its mechanical design is derived from the five-cell normal conducting LEP cavities, which were in operation at CERN for approximately 15 years. Even though the shunt impedance is around 10% lower than for a Side-Coupled Linac (SCL) operating at 704 MHz, the PIMS has the advantage of using the same RF frequency (352 MHz) as all the other accelerating structures in Linac4, thus simplifying and standardising the linac RF system. Furthermore, the simplified mechanical construction of the PIMS, which uses only 84 cells instead of over 400 for the SCL, also reduces construction costs and tuning effort. In this paper we present the electromagnetic design of the PIMS, including the arguments for the choice of a 5% cell-to-cell coupling factor, the shape of the coupling cells,...

  12. LIGHT SOURCE: Physical design of a 10 MeV LINAC for polymer radiation processing

    Science.gov (United States)

    Feng, Guang-Yao; Pei, Yuan-Ji; Wang, Lin; Zhang, Shan-Cai; Wu, Cong-Feng; Jin, Kai; Li, Wei-Min

    2009-06-01

    In China, polymer radiation processing has become one of the most important processing industries. The radiation processing source may be an electron beam accelerator or a radioactive source. Physical design of an electron beam facility applied for radiation crosslinking is introduced in this paper because of it's much higher dose rate and efficiency. Main part of this facility is a 10 MeV travelling wave electron linac with constant impedance accelerating structure. A start to end simulation concerning the linac is reported in this paper. The codes Opera-3d, Poisson-superfish and Parmela are used to describe electromagnetic elements of the accelerator and track particle distribution from the cathode to the end of the linac. After beam dynamic optimization, wave phase velocities in the structure have been chosen to be 0.56, 0.9 and 0.999 respectively. Physical parameters about the main elements such as DC electron gun, iris-loaded periodic structure, solenoids, etc, are presented. Simulation results proves that it can satisfy the industrial requirement. The linac is under construction. Some components have been finished. Measurements proved that they are in a good agreement with the design values.

  13. R & D on Very-High-Current Superconducting Proton Linac, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook Univ., NY (United States)

    2013-03-31

    The aim of this R&D project was to develop a superconducting cavity for a very-­ high-current proton accelerator. The particular application motivating the proposal was a LHC upgrade called the Superconducting Proton Linac, or SPL. Under the grant awarded to Stony Brook University the cavity was designed, a prototype copper cavity, followed by the niobium cavity, were built. A new set of HOM dampers was developed. The cavity has outstanding RF performance parameters – low surface fields, low power loss and all HOMs are fully damped. In fact, it is a “universal cavity” in the sense that it is suited for the acceleration of high-­current protons and well as high current electrons. Its damping of HOM modes is so good that it can see service in a multi-pass linac or an Energy Recovery Linac in addition to the easier service in a single-pass linac. Extensive measurements were made on the cavities and couplers, with the exception of the cold test of the niobium cavity. At the time of this report the cavity has been chemically processed and is ready for vertical testing which will be carried out shortly.

  14. Dark current and radiation shielding studies for the ILC main linac

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, Nikolai V. [Fermilab; Rakhno, I. L. [Fermilab; Solyak, N. A. [Fermilab; Sukhanov, A. [Fermilab; Tropin, I. S. [Fermilab

    2016-12-05

    Electrons of dark current (DC), generated in high-gradient superconducting RF cavities (SRF) due to field emission, can be accelerated up to very high energies—19 GeV in the case of the International Linear Collider (ILC) main linac—before they are removed by focusing and steering magnets. Electromagnetic and hadron showers generated by such electrons can represent a significant radiation threat to the linac equipment and personnel. In our study, an operational scenario is analysed which is believed can be considered as the worst case scenario for the main linac regarding the DC contribution to the radiation environment in the main linac tunnel. A detailed modelling is performed for the DC electrons which are emitted from the surface of the SRF cavities and can be repeatedly accelerated in the high-gradient fields in many SRF cavities. Results of MARS15 Monte Carlo calculations, performed for the current main linac tunnel design, reveal that the prompt dose design level of 25 μSv/hr in the service tunnel can be provided by a 2.3-m thick concrete wall between the main and service ls.

  15. Recirculating linacs for a neutrino factory--Arc optics design and optimization

    CERN Document Server

    Bogacz, S A

    2001-01-01

    A conceptual lattice design for a muon accelerator based on recirculating linacs (Nucl. Instr. and Meth. A 472 (2001) 499, these proceedings) is presented here. The challenge of accelerating and transporting a large phase space of short-lived muons is answered here by presenting a proof-of-principle lattice design for a recirculating linac accelerator. It is the centerpiece of a chain of accelerators consisting of a 3 GeV linac and two consecutive recirculating linear accelerators, which facilitates acceleration starting after ionization cooling at 190 MeV/c and proceeding to 50 GeV. Beam transport issues for large-momentum-spread beams are accommodated by appropriate lattice design choices. The resulting arc optics is further optimized with a sextupole correction to suppress chromatic effects contributing to the emittance dilution. The presented proof-of-principle design of the arc optics with horizontal separation of multi-pass beams can be extended to all passes in both recirculating linacs.

  16. Physics design of a CW high-power proton Linac for accelerator ...

    Indian Academy of Sciences (India)

    [7] T P Wangler, Principles of RF linear accelerators (John Wiley & Sons Inc., 1998). [8] K Shepard et al, Proceedings of the XIX International Linac Conference (Chicago, Illinois) p. 956. [9] C Pagani et al, Design criteria for elliptical cavities, SRF, 2001. [10] P Singh, S V L S Rao, Rajni Pande, T Basak, Shweta Roy, M Aslam, ...

  17. The design of a radio frequency quadrupole LINAC for the RIB ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 59; Issue 6. The design of a radio frequency quadrupole LINAC for the RIB project at VECC Kolkata. V Banerjee Alok Chakrabarti ... for rf structure design study. The beam dynamics and rf-structure design along with the results of the cold model tests will be presented.

  18. Effect of transverse magnetic fields on a simulated in-line 6 MV linac.

    Science.gov (United States)

    St Aubin, J; Steciw, S; Fallone, B G

    2010-08-21

    The effects of a transverse magnetic field on an in-line side-coupled 6 MV linear accelerator are given. The results are directly applicable to a linac-MR system used for real-time image guided adaptive radiotherapy. Our previously designed end-to-end linac simulation incorporated the results from the axisymmetric 2D electron gun program EGN2w. However, since the magnetic fields being investigated are non-axisymmetric in nature for the work presented here, the electron gun simulation was performed using OPERA-3d/SCALA. The simulation results from OPERA-3d/SCALA showed excellent agreement with previous results. Upon the addition of external magnetic fields to our fully 3D linac simulation, it was found that a transverse magnetic field of 6 G resulted in a 45 +/- 1% beam loss, and by 14 G, no electrons were incident on the target. Transverse magnetic fields on the linac simulation produced a highly asymmetric focal spot at the target, which translated into a 13% profile asymmetry at 6 G. Upon translating the focal spot with respect to the target coordinates, profile symmetry was regained at the expense of a lateral shift in the dose profiles. It was found that all points in the penumbra failed a 1%/1 mm acceptance criterion for fields between 4 and 6 G. However, it was also found that the lateral profile shifts were corrected by adjusting the jaw positions asymmetrically.

  19. LINAC-radiosurgery for nonsecreting pituitary adenomas. Long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Runge, M.J.R.; Maarouf, M.; Hunsche, S.; Ruge, M.I.; El Majdoub, F.; Treuer, H.; Sturm, V. [Koeln Univ. (Germany). Dept. of Stereotaxy and Functional Neurosurgery; Kocher, M.; Mueller, R.P. [Koeln Univ. (Germany). Dept. of Radiation Oncology; Voges, J. [Magdeburg Univ. (Germany). Dept. of Stereotactic Neurosurgery

    2012-04-15

    Stereotactic linear accelerator-based radiosurgery (LINAC-RS) is increasingly used for microsurgically inaccessible or recurrent pituitary adenomas. This single-center study evaluates the long-term follow-up after LINAC-RS of nonsecreting pituitary adenomas (NSA). Patients and methods: Between 1992 and August 2008, 65 patients with NSA were treated. Patient treatment and follow-up were conducted according to a prospective protocol. Indications for LINAC-RS were (1) tumor recurrence or (2) residual tumor. Three patients were treated primarily. For analysis of prognostic factors, patients were grouped according to epidemiological or treatment-associated characteristics. Results: A total of 61 patients with a follow-up {>=} 12 months (median 83 months, range 15-186 months, longest follow-up of published radiosurgery series) were evaluated with regard to their clinical, radiological, and endocrinological course. The median tumor volume was 3.5 ml ({+-} 4.3 ml, range 0.3-17.3 ml) treated with a median surface and maximum dose of 13.0 Gy and 29.7 Gy, respectively. Local tumor control was achieved in 98%. One patient died of unrelated cause after 36 months and 1 patient developed a radiation-induced seizure disorder. Visual complications did not occur. In 37 of 41 patients (90.2%), pituitary function remained stable. Maximum dose to the pituitary {<=} 16 Gy and female gender were positive prognostic factors for the preservation of pituitary function. Conclusion: LINAC-RS is a minimally invasive, safe, and effective treatment for recurrent NSA or microsurgically inaccessible residual tumor. LINAC-RS yielded a high rate of local long-term tumor control with a small number of radiation-induced side effects. (orig.)

  20. SU-E-J-202: Performance of the Patient QA Systems in a Hybrid MRI-Linac

    Energy Technology Data Exchange (ETDEWEB)

    Houweling, A; Vries, W de; Wolthaus, J; Woodings, S; Asselen, B van; Kok, J; Lagendijk, J; Raaymakers, B [University Medical Center Utrecht, Utrecht (Netherlands)

    2015-06-15

    Purpose: The first clinical MR-linac will soon become operational, therefore patient plan QA procedures and equipment have to become MRcompatible. Reference dosimetry is affected by the magnetic field, however, relative dosimetry using patient QA systems haven’t been investigated extensively. The purpose of this study was to examine the performance characteristics of the MR-compatible ArcCHECK and Delta4 systems in a transverse 1.5 T magnetic field. Methods: Recently MR-compatible versions of both ArcCheck (Sun Nuclear) and Delta4 (Scandidos) have been developed. To examine the performance characteristics within the magnetic field, the reproducibility, dose linearity, dose rate dependence, field size and angular dependence were evaluated on the MR-linac (8 MV FFF beam, SAD of 142 cm) and a conventional linac (Elekta, 6MV). To allow comparison of the measurements with and without magnetic field, the measurement setup for the conventional linac is adapted to mimic the setup at the MR-linac if possible (e.g. SAD, dose rate). The results from the MR-linac were benchmarked to the results from the conventional linac as being the clinical reference. Results: At the moment of writing, measurements for the Delta4 are still running. Therefore, only the results of the ArcCheck are presented in this abstract. No significant difference was observed in the reproducibility of the ArcCheck (<0.06%) between both linacs. The maximum dose response difference when measuring the dose linearity was less than 0.4% and the varying dose rate resulted in maximal dose differences of 1.0% for both linacs. Response variation for varying field sizes was <2.6% at the conventional linac, and <1.0% at the MR-linac. Angular response was similar for both linacs. Conclusion: The reproducibility, dose linearity, dose rate dependence, field size and angular dependence of the MR compatible ArcCheck were not influenced by the presence of a transverse 1.5 T magnetic field. The results for the Delta4 are

  1. Predatory functional morphology in raptors: interdigital variation in talon size is related to prey restraint and immobilisation technique.

    Directory of Open Access Journals (Sweden)

    Denver W Fowler

    Full Text Available Despite the ubiquity of raptors in terrestrial ecosystems, many aspects of their predatory behaviour remain poorly understood. Surprisingly little is known about the morphology of raptor talons and how they are employed during feeding behaviour. Talon size variation among digits can be used to distinguish families of raptors and is related to different techniques of prey restraint and immobilisation. The hypertrophied talons on digits (D I and II in Accipitridae have evolved primarily to restrain large struggling prey while they are immobilised by dismemberment. Falconidae have only modest talons on each digit and only slightly enlarged D-I and II. For immobilisation, Falconini rely more strongly on strike impact and breaking the necks of their prey, having evolved a 'tooth' on the beak to aid in doing so. Pandionidae have enlarged, highly recurved talons on each digit, an adaptation for piscivory, convergently seen to a lesser extent in fishing eagles. Strigiformes bear enlarged talons with comparatively low curvature on each digit, part of a suite of adaptations to increase constriction efficiency by maximising grip strength, indicative of specialisation on small prey. Restraint and immobilisation strategy change as prey increase in size. Small prey are restrained by containment within the foot and immobilised by constriction and beak attacks. Large prey are restrained by pinning under the bodyweight of the raptor, maintaining grip with the talons, and immobilised by dismemberment (Accipitridae, or severing the spinal cord (Falconini. Within all raptors, physical attributes of the feet trade off against each other to attain great strength, but it is the variable means by which this is achieved that distinguishes them ecologically. Our findings show that interdigital talon morphology varies consistently among raptor families, and that this is directly correlative with variation in their typical prey capture and restraint strategy.

  2. Predatory Functional Morphology in Raptors: Interdigital Variation in Talon Size Is Related to Prey Restraint and Immobilisation Technique

    Science.gov (United States)

    Fowler, Denver W.; Freedman, Elizabeth A.; Scannella, John B.

    2009-01-01

    Despite the ubiquity of raptors in terrestrial ecosystems, many aspects of their predatory behaviour remain poorly understood. Surprisingly little is known about the morphology of raptor talons and how they are employed during feeding behaviour. Talon size variation among digits can be used to distinguish families of raptors and is related to different techniques of prey restraint and immobilisation. The hypertrophied talons on digits (D) I and II in Accipitridae have evolved primarily to restrain large struggling prey while they are immobilised by dismemberment. Falconidae have only modest talons on each digit and only slightly enlarged D-I and II. For immobilisation, Falconini rely more strongly on strike impact and breaking the necks of their prey, having evolved a ‘tooth’ on the beak to aid in doing so. Pandionidae have enlarged, highly recurved talons on each digit, an adaptation for piscivory, convergently seen to a lesser extent in fishing eagles. Strigiformes bear enlarged talons with comparatively low curvature on each digit, part of a suite of adaptations to increase constriction efficiency by maximising grip strength, indicative of specialisation on small prey. Restraint and immobilisation strategy change as prey increase in size. Small prey are restrained by containment within the foot and immobilised by constriction and beak attacks. Large prey are restrained by pinning under the bodyweight of the raptor, maintaining grip with the talons, and immobilised by dismemberment (Accipitridae), or severing the spinal cord (Falconini). Within all raptors, physical attributes of the feet trade off against each other to attain great strength, but it is the variable means by which this is achieved that distinguishes them ecologically. Our findings show that interdigital talon morphology varies consistently among raptor families, and that this is directly correlative with variation in their typical prey capture and restraint strategy. PMID:19946365

  3. 3D numerical simulation of a lab-on-a-chip--increasing measurement sensitivity of interdigitated capacitors by passivation optimization.

    Science.gov (United States)

    Jungreuthmayer, Christian; Birnbaumer, Gerald M; Zanghellini, Juergen; Ertl, Peter

    2011-04-07

    Interdigital electrode structures (IDES) play a major role in many technical and analytical applications. In particular, they are a key technology in modern lab-on-a-chip (LOC) devices. As high sensitivity is a key component of any (bio)analytical method, the presented work is aimed at designing a novel dielectric sensing system, which exhibits maximum sensor sensitivity using passivated dielectric microsensors. Although the implementation of high-ε(r) dielectric passivation materials such as tantalum oxide or titanium oxide showed increased sensor sensitivity by a factor of 5, simulations revealed that sensor sensitivity is ultimately determined by the dielectric properties of the analyte. Ideally, dielectric properties of the passivation material need to be adjusted to the dielectric properties of the material under investigation and any deviations (e.g. higher or lower dielectric constants) will result in significant loss of sensitivity. To address these shortcomings we have developed a novel dielectric sensing concept based on a dual-material passivation geometry. The novel design consists of electric flux barriers that are layered between the finger electrodes, as well as electric flux guides which are located above the electrode structures that direct the entire generated electric flux to the object under investigation. Our 3D numerical results clearly show that the novel design offers two main advantages: firstly, the measurement sensitivity is further increased by more than a factor of two in comparison to a homogeneous passivation material sensing strategy. Secondly, maximum sensitivity for a given set of finger geometries can be achieved using a single sensor design regardless of the frequency-dependent dielectric properties of the measured objects. Hence, the novel approach is capable of reducing design and manufacturing costs of lab-on-a-chip devices.

  4. III-V/Si Tandem Cells Utilizing Interdigitated Back Contact Si Cells and Varying Terminal Configurations: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Schnabel, Manuel; Klein, Talysa R.; Jain, Nikhil; Essig, Stephanie; Schulte-Huxel, Henning; Warren, Emily; van Hest, Maikel F. A. M.; Geisz, John; Stradins, Paul; Tamboli, Adele; Rienacker, Michael; Merkle, Agnes; Schmidt, Jan; Brendel, Rolf; Peibst, Robby

    2017-07-11

    Solar cells made from bulk crystalline silicon (c-Si) dominate the market, but laboratory efficiencies have stagnated because the current record efficiency of 26.3% is already very close to the theoretical limit of 29.4% for a single-junction c-Si cell. In order to substantially boost the efficiency of Si solar cells we have been developing stacked III-V/Si tandem cells, recently attaining efficiencies above 32% in four-terminal configuration. In this contribution, we use state-of-the-art III-V cells coupled with equivalent circuit simulations to compare four-terminal (4T) to three- and two-terminal (3T, 2T) operation. Equivalent circuit simulations are used to show that tandem cells can be operated just as efficiently using three terminals as with four terminals. However, care must be taken not to overestimate 3T efficiency, as the two circuits used to extract current interact, and a method is described to accurately determine this efficiency. Experimentally, a 4T GaInP/Si tandem cell utilizing an interdigitated back contact cell is shown, exhibiting a 4T efficiency of 31.5% and a 2T efficiency of 28.1%. In 3T configuration, it is used to verify the finding from simulation that 3T efficiency is overestimated when interactions between the two circuits are neglected. Considering these, a 3T efficiency approaching the 4T efficiency is found, showing that 3T operation is efficient, and an outlook on fully integrated high-efficiency 3T and 2T tandem cells is given.

  5. Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac.

    Science.gov (United States)

    St Aubin, J; Santos, D M; Steciw, S; Fallone, B G

    2010-09-01

    Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak

  6. Design and experiments of RF transverse focusing in S-Band, 1 MeV standing wave linac

    Energy Technology Data Exchange (ETDEWEB)

    Mondal, J., E-mail: jmondal@barc.gov.in; Chandan, Shiv; Parashar, S.; Bhattacharjee, D.; Tillu, A.R.; Tiwari, R.; Jayapraksh, D.; Yadav, V.; Banerjee, S.; Choudhury, N.; Ghodke, S.R.; Dixit, K.P.; Nimje, V.T.

    2015-09-21

    S-Band standing wave (SW) linacs in the range of 1–10 MeV have many potential industrial applications world wide. In order to mitigate the industrial requirement it is required to reduce the overall size and weight of the system. On this context a 2856 M Hz, 1 Me V, bi-periodic on axis coupled self transverse focused SW linac has been designed and tested. The RF phase focusing is achieved by introducing an asymmetric field distribution in the first cell of the 1 MeV linac. The pulsed electron beam of 40 keV, 650 mA and 5 µs duration is injected from a LaB{sub 6} thermionic gun. This paper presents the structure design, beam dynamics simulation, fabrication and experimental results of the 1 MeV auto-focusing SW linac.

  7. Observation of a H- Beam at the CERN Linac 4 Test Stand using a Pepper-pot

    CERN Document Server

    Delerue, N; Midttun, O; Scrivens, R; Tsesmelis, E

    2010-01-01

    Pepper-pot based transverse emittance measurement has the advantage of providing a fast (single shot) measurement with a relatively simple hardware. We report on the installation of a pepper-pot at the CERN Linac 4 test stand.

  8. SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, M; Fallone, B [Cross Cancer Institute, Edmonton, AB (Canada)

    2016-06-15

    Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

  9. Improved beam extraction for a negative hydrogen ion source for the LHC injector chain upgrade, Linac4

    CERN Document Server

    Midttun, Øystein; Scrivens, Richard

    In the scope of an upgrade of the injector chain of CERN’s accelerator complex, a new linear accelerator, Linac4, is under construction. This accelerator will replace the existing 50 MeV proton linac, Linac2. By increasing the beam energy to 160 MeV, Linac4 makes it possible to double the brightness in the PSB, and ultimately increase the luminosity in the LHC. Linac4 will accelerate beams of negative hydrogen (H-) to be injected into the PSB by multi-turn, charge exchange injection. The ion source was initially based on the non-caesiated RF-volume source from DESY. However, the beam extraction from this source could not handle the 45 keV beam energy required by the RFQ. A new beam extraction system has therefore been designed, via IBSimu simulations [1], to extract and transport the H- ion beam respecting the Linac4 requirements. Key features of the extraction system is a tuneable puller voltage to adapt the extraction field to the ion and electron beam currents, and a magnetized Einzel lens to dump the co...

  10. First H- beam accelerated at Linac4: 3MeV done, 157 MeV to go!

    CERN Multimedia

    Linac4 Project Team

    2013-01-01

    On 14 November, the first H- (one proton surrounded by two electrons) beam was accelerated to the energy of 3 MeV in the Linac4 - the new linear accelerator that will replace Linac2 as low-energy injector in the LHC accelerator chain.      A view of the Linac4 taken during the recent tests (top image) and the current measured by the instruments at the end of the acceleration line on 14 November (bottom image). Images: Linac4 collaboration. Using the recently installed Radio Frequency Quadrupole (RFQ) accelerator, 13 mA of current were accelerated to the energy of 3 MeV. After the successful commissioning of the Linac4 RFQ at the 3 MeV test stand completed during the first months of 2013, the whole equipment (composed of the RFQ itself, the following Medium Energy Beam Transport line and its diagnostic line) were moved to the Linac4 tunnel during summer and installed in their final position. In the meantime, a new ion source was assembled, installed and successfu...

  11. Design of the Compact Linear Collider main linac accelerating structure made from two halves

    Directory of Open Access Journals (Sweden)

    Hao Zha

    2017-04-01

    Full Text Available Milling on two longitudinally split halves is one method to manufacture accelerating structures. This method is simple and allows one to avoid electromagnetic fields at bonding joints, making it attractive in manufacturing high-gradient accelerating structures. An X-band structure design with strong wakefield damping based on this manufacturing approach is studied in this work as an alternative design for the Compact Linear Collider (CLIC main linac accelerating structures. The geometry of the structure is optimized to greatly reduce the surface fields, improve the efficiency, and suppress the wakefield. This structure features the baseline design of the CLIC main linac with additional advantages. This study may serve as a reference for designing other high frequency-band corrugated structures.

  12. Design and construction of drift tube linac cavities for RIKEN RI Beam Factory

    Science.gov (United States)

    Suda, K.; Sakamoto, N.; Yamada, K.; Arai, S.; Chiba, Y.; Kase, M.; Okuno, H.; Watanabe, Y.; Kamigaito, O.

    2013-09-01

    A new injector linac "RILAC2", has recently been constructed at the RIKEN RI Beam Factory. The main part of the RILAC2 is a drift tube linac that consists of three newly designed cavities. These cavities operate in continuous wave (CW) mode at a fixed frequency of 36.5 MHz. Their structure is based on a quarter-wavelength resonator because this is the smallest resonator available in this frequency range among the available structures. We adopted the direct coupling method in the construction of these cavities. A power amplifier was directly coupled to the cavity without a long transmission line to reduce the installation area and simultaneously reduce construction cost. A detailed cavity and coupler design was carried out via simulation. Our work also describes the design process using three-dimensional electromagnetic simulation software. Construction and operation tests are also shown.

  13. Beam simulations with initial bunch noise in superconducting RF proton linacs

    CERN Document Server

    Tückmantel, J

    2010-01-01

    Circular machines are plagued by coupled bunch instabilities (CBI), driven by impedance peaks, where then all cavity higher order modes (HOMs) are possible drivers. Limiting the CBI growth rate is the fundamental reason that all superconducting rf cavities in circular machines are equipped with HOM dampers. The question arises if for similar reasons HOM damping would not be imperative also in high current superconducting rf proton linacs. Therefore we have simulated the longitudinal bunched beam dynamics in such machines, also including charge and position noise on the injected bunches. Simulations were executed for a generic linac with properties close to the planned SPL at CERN, SNS, or Project X at FNAL. It was found that with strong bunch noise and monopole HOMs with high Qext large beam scatter, possibly exceeding the admittance of a receiving machine, cannot be excluded. A transverse simulation shows similar requirements. Therefore including initial bunch noise in any beam dynamic study on superconducti...

  14. Investigation of the mechanical performance of Siemens linacs components during arc

    DEFF Research Database (Denmark)

    Rowshanfarzad, Pejman; Häring, Peter; Lynggaard Riis, Hans

    2015-01-01

    BACKGROUND: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an a......BACKGROUND: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction...... with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. METHODS: The EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due...

  15. A geometrical model for the Monte Carlo simulation of the TrueBeam linac.

    Science.gov (United States)

    Rodriguez, M; Sempau, J; Fogliata, A; Cozzi, L; Sauerwein, W; Brualla, L

    2015-06-07

    Monte Carlo simulation of linear accelerators (linacs) depends on the accurate geometrical description of the linac head. The geometry of the Varian TrueBeam linac is not available to researchers. Instead, the company distributes phase-space files of the flattening-filter-free (FFF) beams tallied at a plane located just upstream of the jaws. Yet, Monte Carlo simulations based on third-party tallied phase spaces are subject to limitations. In this work, an experimentally based geometry developed for the simulation of the FFF beams of the Varian TrueBeam linac is presented. The Monte Carlo geometrical model of the TrueBeam linac uses information provided by Varian that reveals large similarities between the TrueBeam machine and the Clinac 2100 downstream of the jaws. Thus, the upper part of the TrueBeam linac was modeled by introducing modifications to the Varian Clinac 2100 linac geometry. The most important of these modifications is the replacement of the standard flattening filters by ad hoc thin filters. These filters were modeled by comparing dose measurements and simulations. The experimental dose profiles for the 6 MV and 10 MV FFF beams were obtained from the Varian Golden Data Set and from in-house measurements performed with a diode detector for radiation fields ranging from 3  ×  3 to 40  ×  40 cm(2) at depths of maximum dose of 5 and 10 cm. Indicators of agreement between the experimental data and the simulation results obtained with the proposed geometrical model were the dose differences, the root-mean-square error and the gamma index. The same comparisons were performed for dose profiles obtained from Monte Carlo simulations using the phase-space files distributed by Varian for the TrueBeam linac as the sources of particles. Results of comparisons show a good agreement of the dose for the ansatz geometry similar to that obtained for the simulations with the TrueBeam phase-space files for all fields and depths considered, except for

  16. Commissioning of the Electron Line of the Linac Coherent Light Source. Dose Rate Measurements and Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Santana Leitner, M; Bauer, J.M.; Fasso, A.; Liu, J.C.; Mao, X.S.; Prinz, A.; Rokni, H.; /SLAC; Sanami, T.; /SLAC /KEK, Tsukuba; Vollaire, J.; /SLAC

    2009-05-20

    The Linac Coherent Light Source at the SLAC National Accelerator Laboratory (operated by Stanford University for the US Department of Energy) is the world's first hard X-ray Free Electron Laser machine. It uses high energy electrons delivered by a linac to create ultrafast and brilliant X-ray pulses that can be used as a 'high-speed' camera to obtain images of atoms and molecules. LCLS is a pioneer machine and, as such, its design has encountered unprecedented challenges, the solutions to which will benefit future facilities of its kind across the globe. This article describes the radiation protection aspects of LCLS electron beamlines. Special emphasis is put on the successful commissioning of the LCLS electron line, where, for all examined loss sources, the measured prompt and residual dose rates are in agreement with or below the values predicted through detailed Monte Carlo simulations, used earlier to design the shielding.

  17. Superconducting linac beam dynamics with high-order maps for RF resonators

    CERN Document Server

    Geraci, A A; Pardo, R C; 10.1016/j.nima.2003.11.177

    2004-01-01

    The arbitrary-order map beam optics code COSY Infinity has recently been adapted to calculate accurate high-order ion-optical maps for electrostatic and radio-frequency accelerating structures. The beam dynamics of the superconducting low-velocity positive-ion injector linac for the ATLAS accelerator at Argonne National Lab is used to demonstrate some advantages of the new simulation capability. The injector linac involves four different types of superconducting accelerating structures and has a total of 18 resonators. The detailed geometry for each of the accelerating cavities is included, allowing an accurate representation of the on- and off-axis electric fields. The fields are obtained within the code from a Poisson-solver for cylindrically symmetric electrodes of arbitrary geometry. The transverse focusing is done with superconducting solenoids. A detailed comparison of the transverse and longitudinal phase space is made with the conventional ray-tracing code LINRAY. The two codes are evaluated for ease ...

  18. A geometrical model for the Monte Carlo simulation of the TrueBeam linac

    Science.gov (United States)

    Rodriguez, M.; Sempau, J.; Fogliata, A.; Cozzi, L.; Sauerwein, W.; Brualla, L.

    2015-06-01

    Monte Carlo simulation of linear accelerators (linacs) depends on the accurate geometrical description of the linac head. The geometry of the Varian TrueBeam linac is not available to researchers. Instead, the company distributes phase-space files of the flattening-filter-free (FFF) beams tallied at a plane located just upstream of the jaws. Yet, Monte Carlo simulations based on third-party tallied phase spaces are subject to limitations. In this work, an experimentally based geometry developed for the simulation of the FFF beams of the Varian TrueBeam linac is presented. The Monte Carlo geometrical model of the TrueBeam linac uses information provided by Varian that reveals large similarities between the TrueBeam machine and the Clinac 2100 downstream of the jaws. Thus, the upper part of the TrueBeam linac was modeled by introducing modifications to the Varian Clinac 2100 linac geometry. The most important of these modifications is the replacement of the standard flattening filters by ad hoc thin filters. These filters were modeled by comparing dose measurements and simulations. The experimental dose profiles for the 6 MV and 10 MV FFF beams were obtained from the Varian Golden Data Set and from in-house measurements performed with a diode detector for radiation fields ranging from 3  ×  3 to 40  ×  40 cm2 at depths of maximum dose of 5 and 10 cm. Indicators of agreement between the experimental data and the simulation results obtained with the proposed geometrical model were the dose differences, the root-mean-square error and the gamma index. The same comparisons were performed for dose profiles obtained from Monte Carlo simulations using the phase-space files distributed by Varian for the TrueBeam linac as the sources of particles. Results of comparisons show a good agreement of the dose for the ansatz geometry similar to that obtained for the simulations with the TrueBeam phase-space files for all fields and depths considered, except for the

  19. Misalignment and Error Studies of the High Energy Section of the HIE-ISOLDE Linac

    CERN Document Server

    Fraser, MA

    2009-01-01

    The sensitivity of the beam to misalignment and error is investigated in order to specify design tolerances for the high energy section of the superconducting upgrade to the REXISOLDE linac. Alongside misalignment, the machine errors studied include error in the transverse Twiss parameters at injection, error in the solenoid fields, error in the beam position monitors, as well as fast and static errors in the phase and voltage of the cavities. The tolerances were specified by tracking a single particle representing the beam centroid in a matrix model of the linac, with the realistic fields parameterised in transfer matrices. The matrixmodel was verified using the TRACK code, which carries out the numerical integration of the equations of motion for multi-particle beams in the realistic fields.

  20. Bunch Length Measurements at the SLS Linac Using Electro Optical Sampling

    CERN Document Server

    Steffen, Bernd; Schmüser, Peter; Simrock, Stefan

    2004-01-01

    The temporal profile of the electron bunches in the SLS Linac was determined by means of electro-optical techniques. In a first experiment a mode locked Ti:Sa Laser with 15 fs pulse width (FWHM) was used for coincidence and sampling measurements between the laser pulse and the coherent transition radiation (CTR) generated by short electron bunches. A synchronization accuracy of 70 fs rms between the 3 GHz Linac RF and the 81 MHz repetition frequency of the laser was achieved, which is important for the optimum time resolution of the applied electro-optical sampling technique. In a second experiment a mode locked Nd:YAG laser with 400 ps long pulses will be used for electro-optical autocorrelation measurements between the CTR and the laser pulses. This alternative technique promises single shot capability and requires much relaxed synchronization stability between laser and electron beam.

  1. PIC Simulations in Low Energy Part of PIP-II Proton Linac

    Energy Technology Data Exchange (ETDEWEB)

    Romanov, Gennady

    2014-07-01

    The front end of PIP-II linac is composed of a 30 keV ion source, low energy beam transport line (LEBT), 2.1 MeV radio frequency quadrupole (RFQ), and medium energy beam transport line (MEBT). This configuration is currently being assembled at Fermilab to support a complete systems test. The front end represents the primary technical risk with PIP-II, and so this step will validate the concept and demonstrate that the hardware can meet the specified requirements. SC accelerating cavities right after MEBT require high quality and well defined beam after RFQ to avoid excessive particle losses. In this paper we will present recent progress of beam dynamic study, using CST PIC simulation code, to investigate partial neutralization effect in LEBT, halo and tail formation in RFQ, total emittance growth and beam losses along low energy part of the linac.

  2. New injectors the Linac4 project and the new H− source

    CERN Document Server

    Lettry, J

    2015-01-01

    Linac4 is a new 160 MeV linear accelerator designed to improve by a factor of 2 the beam brightness out of the LHC injection chain for the needs of the LHC luminosity upgrade. The project started in 2008 and beam commissioning takes place in 2014–2015. The new linac accelerates H− ions that are then stripped at injection into the PS Booster; production of the H− beam takes place in a state-of-the-art ion source of the RF-driven caesiated surface type. Acceleration is provided by four different accelerating sections matched to the increasing beam velocity, including two of novel designs, and focusing is provided by a combination of permanent-magnet and electromagnetic quadrupoles.

  3. CAS on Free-Electron Lasers and Energy Recovery Linacs in Hamburg

    CERN Multimedia

    CERN Accelerator School

    2016-01-01

    The CERN Accelerator School (CAS) and DESY held a jointly-organised specialised course on Free-Electron Lasers and Energy Recovery Linacs (FELs and ERLs) in Hamburg, Germany, from 31 May to 10 June 2016.      The course was held in the Hotel Scandic Emporio in Hamburg and was attended by 68 participants of 13 nationalities, coming from countries as far away as China, Iran and Japan. The intensive programme comprised 44 lectures and one seminar. Following introductory lectures on electromagnetism, relativity and synchrotron radiation issues, the basic requirements of linacs and ERLs were discussed. Detailed lectures on the theory of FEL science followed. Undulators and the process of lasing and seeding were covered in some detail along with lectures on various beam dynamics and beam control issues. Case studies, for which seven hours were allocated, completed the academic programme. For these, the students were divided into small groups and tasked with completing the basic desig...

  4. Alternating Phase Focusing in Low-Velocity Heavy-Ion Superconducting Linac

    CERN Document Server

    Ostroumov, P N

    2004-01-01

    The low-charge-state injector linac of the RIA post-accelerator is based on ~60 independently phased SC resonators providing total ~70 MV accelerating potential. The low charge-state beams, however, require stronger transverse focusing, particularly at low velocities, than is used in existing SC ion linacs. For the charge-to-mass ratios considered here (q/A = 1/66) the proper focusing can be reached by the help of strong SC solenoid lenses with the field up to 15 T. Magnetic field of the solenoids can be reduced to 9 T applying an Alternating Phase Focusing (APF). A method to set the rf field phases has been developed and studied both analytically and by the help of the three-dimensional ray tracing code. The paper discusses the results of these studies.

  5. The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Alonso-Mori, Roberto; Caronna, Chiara; Chollet, Matthieu; Curtis, Robin; Damiani, Daniel S.; Defever, Jim; Feng, Yiping; Flath, Daniel L.; Glownia, James M. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Lee, Sooheyong [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Hasylab at DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Lemke, Henrik T.; Nelson, Silke; Bong, Eric; Sikorski, Marcin; Song, Sanghoon; Srinivasan, Venkat; Stefanescu, Daniel; Zhu, Diling; Robert, Aymeric, E-mail: aymeric@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-14

    A description of the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source is presented. Recent highlights illustrate the coherence properties of the source as well as some recent dynamics measurements and future directions. The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4–25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. A description of the instrument capabilities and recent achievements is presented.

  6. Comparison of coaxial higher order mode couplers for the CERN Superconducting Proton Linac study

    CERN Document Server

    AUTHOR|(CDS)2085329; Gerigk, Frank; Van Rienen, Ursula

    2017-01-01

    Higher order modes (HOMs) may affect beam stability and refrigeration requirements of superconducting proton linacs such as the Superconducting Proton Linac, which is studied at CERN. Under certain conditions beam-induced HOMs can accumulate sufficient energy to destabilize the beam or quench the superconducting cavities. In order to limit these effects, CERN considers the use of coaxial HOM couplers on the cutoff tubes of the 5-cell superconducting cavities. These couplers consist of resonant antennas shaped as loops or probes, which are designed to couple to potentially dangerous modes while sufficiently rejecting the fundamental mode. In this paper, the design process is presented and a comparison is made between various designs for the high-beta SPL cavities, which operate at 704.4 MHz. The rf and thermal behavior as well as mechanical aspects are discussed. In order to verify the designs, a rapid prototype for the favored coupler was fabricated and characterized on a low-power test-stand.

  7. Single pass electron beam cooling of gold ions between EBIS LINAC and booster is theoretically possible!

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, A.

    2011-01-01

    Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Many issues, regarding a low energy high current electron beam that is needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, were examined. Computations and some experimental data indicate that none of these issues is a show stopper. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in about one meter. Hence, this option cooling deserves further more serious considerations.

  8. Imperfection Tolerances For On-line Dipsersion Free Steering in the Main LINAC of CLIC

    CERN Document Server

    Pfingstner, J; Schulte, D

    2013-01-01

    Long-term ground motion misaligns the elements of the main linac of CLIC over time. Especially the misaligned quadrupoles create dispersion and hence the beam quality is decreased gradually due to an effect called chromatic dilution. Over longer time periods, orbit feedback systems are not capable to fully recover the beam quality and have to be supplemented by dispersion correction algorithms. In this paper, such and dispersion correction algorithm is presented, which is an extended version of the well-known dispersion free steering algorithm. This extended algorithm can recover the beam quality over long time scaled without stopping the accelerator operation (on-line). Tolerances for different imperfections of the system have been identified and a strong sensitivity to the resolution of the wake field monitors of the main linac accelerating structures has been identified. This problem can be mitigated by using a local excitation scheme as will be shown in this work.

  9. Niobium coaxial quarter-wave cavities for the New Delhi booster linac

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W. [Argonne National Lab., IL (United States); Roy, A.; Potukuchi, P.N. [Nuclear Science Centre, New Delhi (India)

    1993-07-01

    This paper reports the design and construction status of a prototype superconducting niobium accelerating structure consisting of a pair of quarter-wave coaxial-line cavities which are strongly coupled with a superconducting loop. Quarter-wave resonators are two-gap accelerating structures and are relatively short, so that a large number of independently-phased cavities is required for a linac. Strongly coupling several cavities can reduce the number of independently-phased elements, but at the cost of reducing the range of useful velocity acceptance for each element. Coupling two cavities splits the accelerating rf eigenmode into two resonant modes each of which covers a portion of the full velocity acceptance range of the original single cavity mode. Using both of these resonant modes makes feasible the use of coupled cavity pairs for a linac with little loss m velocity acceptance. Design details for the niobium cavity pair and the results of preliminary tests of multipacting behavior are discussed.

  10. First operation of ATLAS using the PII linac and a comparison to tandem injection

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, R.C.; Bollinger, L.M.; Billquist, P.J.; Bogaty, J.M.; Clifft, B.E.; Markovich, P.; Munson, F.H.; Shepard, K.W.; Zinkann, G.P.

    1991-01-01

    The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 kV platform and a very low-velocity superconducting linac. The PII project is nearing completion. First beam from the complete system is expected in early 1992. Beam tests and experiments using a partially completed PII linac have demonstrated that the technical design goals are being met. The results of the early beam tests and first experiments will be discussed and compared to the performance of ATLAS with tandem injection. 10 refs., 2 figs.

  11. First operation of ATLAS using the PII linac and a comparison to tandem injection

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, R.C.; Bollinger, L.M.; Billquist, P.J.; Bogaty, J.M.; Clifft, B.E.; Markovich, P.; Munson, F.H.; Shepard, K.W.; Zinkann, G.P.

    1991-12-31

    The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 kV platform and a very low-velocity superconducting linac. The PII project is nearing completion. First beam from the complete system is expected in early 1992. Beam tests and experiments using a partially completed PII linac have demonstrated that the technical design goals are being met. The results of the early beam tests and first experiments will be discussed and compared to the performance of ATLAS with tandem injection. 10 refs., 2 figs.

  12. Preliminary RF Test in PLS 2.5GeV Linac for PAL-XFEL

    CERN Document Server

    Hwang, W H; Han, Y J; Huang, J Y; Kim, H G; Lee, W W

    2005-01-01

    In PALXFEL [1], the specification of the beam energy spread and rf phase is tighter than PLS Linac. We examined the rf performance in the present PLS 2.5GeV Linac. The beam energy is changed by cooling temperature, air condition, and modulator high voltage jitter. The main factor to change the beam energy is the rf phase drift by environmental conditions. We measured rf phase drift according to the variation of environmental condition and cooling temperature. We reduced the beam energy drift and the rf phase drift in long-term by improvement of cooling and air conditioning control system. Also, rf phase compensation system is needed for stable beam quality. This paper describes the microwave system for the PALXFEL the rf phase measurement and phase compensation system.

  13. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions.

    Science.gov (United States)

    Valerio-Lizarraga, Cristhian A; Lallement, Jean-Baptiste; Leon-Monzon, Ildefonso; Lettry, Jacques; Midttun, Øystein; Scrivens, Richard

    2014-02-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H(-) beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  14. Stabilization of the Beam Intensity in the Linac at the CTF3 CLIC Test Facility

    CERN Document Server

    Dubrovskiy, A; Bathe, BN; Srivastava, S

    2013-01-01

    A new electron beam stabilization system has been introduced in CTF3 in order to open new possibilities for CLIC beam studies in ultra-stable conditions and to provide a sustainable tool to keep the beam intensity and energy at its reference values for long term operations. The stabilization system is based on a pulse-to-pulse feedback control of the electron gun to compensate intensity deviations measured at the end of the injector and at the beginning of the linac. Thereby it introduces negligible beam distortions at the end of the linac and it significantly reduces energy deviations. A self-calibration mechanism has been developed to automatically configure the feedback controller for the optimum performance. The residual intensity jitter of 0.045% of the stabilized beam was measured whereas the CLIC requirement is 0.075%.

  15. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Valerio-Lizarraga, Cristhian A., E-mail: cristhian.alfonso.valerio.lizarraga@cern.ch [CERN, Geneva (Switzerland); Departamento de Investigación en Física, Universidad de Sonora, Hermosillo (Mexico); Lallement, Jean-Baptiste; Lettry, Jacques; Scrivens, Richard [CERN, Geneva (Switzerland); Leon-Monzon, Ildefonso [Facultad de Ciencias Fisico-Matematicas, Universidad Autónoma de Sinaloa, Culiacan (Mexico); Midttun, Øystein [CERN, Geneva (Switzerland); University of Oslo, Oslo (Norway)

    2014-02-15

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H{sup −} beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  16. Septa and Distributor Developments for H- Injection into the Booster from LINAC4

    CERN Document Server

    Borburgh, J; Fowler, T; Hourican, M; Weterings, W

    2008-01-01

    The construction of Linac4 requires the modification of the existing injection system of the CERN PS Booster. A new transfer line will transport 160 MeV H- ions to this machine. A system of 5 pulsed magnets (BIDIS) and 3 vertical septa (BISMV) will distribute and inject the Linac pulses into the four-vertically separated Booster rings. Subsequently the beam will be injected horizontally, using a local bump created with bumpers (BS magnets) to bring the injected H- beam together with the orbiting proton beam onto the stripper foil. To accommodate the injected H- beam, the first of the BS magnets will have to be a septum-like device, deflecting only the orbiting beam. This paper highlights the requirements and technical issues and describes the solutions to be adopted for both the BIDIS and BISMV. The results of initial prototype testing of the BIDIS magnet will also be presented.

  17. An improvement in IMRT QA results and beam matching in linacs using statistical process control.

    Science.gov (United States)

    Gagneur, Justin D; Ezzell, Gary A

    2014-09-08

    The purpose of this study is to apply the principles of statistical process control (SPC) in the context of patient specific intensity-modulated radiation therapy (IMRT) QA to set clinic-specific action limits and evaluate the impact of changes to the multileaf collimator (MLC) calibrations on IMRT QA results. Ten months of IMRT QA data with 247 patient QAs collected on three beam-matched linacs were retrospectively analyzed with a focus on the gamma pass rate (GPR) and the average ratio between the measured and planned doses. Initial control charts and action limits were calculated. Based on this data, changes were made to the leaf gap parameter for the MLCs to improve the consistency between linacs. This leaf gap parameter is tested monthly using a MLC sweep test. A follow-up dataset with 424 unique QAs were used to evaluate the impact of the leaf gap parameter change. The initial data average GPR was 98.6% with an SPC action limit of 93.7%. The average ratio of doses was 1.003, with an upper action limit of 1.017 and a lower action limit of 0.989. The sweep test results for the linacs were -1.8%, 0%, and +1.2% from nominal. After the adjustment of the leaf gap parameter, all sweep test results were within 0.4% of nominal. Subsequently, the average GPR was 99.4% with an SPC action limit of 97.3%. The average ratio of doses was 0.997 with an upper action limit of 1.011 and a lower action limit of 0.981. Applying the principles of SPC to IMRT QA allowed small differences between closely matched linacs to be identified and reduced. Ongoing analysis will monitor the process and be used to refine the clinical action limits for IMRT QA.

  18. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

    DEFF Research Database (Denmark)

    Zhu, Diling; Feng, Yiping; Stoupin, Stanislav

    2014-01-01

    A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High...... the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance. © 2014 AIP Publishing LLC....

  19. Analysis of HOM Problems in the C-ADS Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Burn [Chinese Academy of Sciences (CAS), Lanzhou (China). Inst. of Modern Physics; Ng, King Yuen [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-05-18

    Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.

  20. The design of a radio frequency quadrupole LINAC for the RIB ...

    Indian Academy of Sciences (India)

    2The Institute of Physical and Chemical Research (RIKEN), Hirosawa 2-1, Saitama 351-0198, Japan. £Email: vaishali@veccal.ernet.in. Abstract. A radio frequency quadrupole LINAC has been designed for the VECC-RIB project for an input beam energy of 1.0 keV/u and q A. 1 16. The output energy will be about 90 keV/u ...