WorldWideScience

Sample records for reversible perfusion defects

  1. Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

    International Nuclear Information System (INIS)

    Kim, D. E.; Park, S. A.; Kim, C. K.; Chang, J. A.; Jeong, J. W.; Oh, S. G.; Lee, C.

    2007-01-01

    It appears logical that myocardial perfusion should be fixed and not reversible, in the territory supplied by a dilated coronary artery. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Sixty-six patients that underwent M-SPECT within 24 hours of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis. This study shows that the predictive value of reversible perfusion defects on M-SPECT early after stent implantation with respect to the incidence of late restenosis was 47% in patients with a reversible defect, and 18% in those without it

  2. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  3. Reversible cold-induced abnormalities in myocardial perfusion and function in systemic sclerosis

    International Nuclear Information System (INIS)

    Alexander, E.L.; Firestein, G.S.; Weiss, J.L.; Heuser, R.R.; Leitl, G.; Wagner, H.N. Jr.; Brinker, J.A.; Ciuffo, A.A.; Becker, L.C.

    1986-01-01

    The effects of peripheral cold exposure on myocardial perfusion and function were studied in 13 patients with scleroderma without clinically evident myocardial disease. Ten patients had at least one transient, cold-induced, myocardial perfusion defect visualized by thallium-201 scintigraphy, and 12 had reversible, cold-induced, segmental left ventricular hypokinesis by two-dimensional echocardiography. The 10 patients with transient perfusion defects all had anatomically corresponding ventricular wall motion abnormalities. No one in either of two control groups (9 normal volunteers and 7 patients with chest pain and normal coronary arteriograms) had cold-induced abnormalities. This study is the first to show the simultaneous occurrence of cold-induced abnormalities in myocardial perfusion and function in patients with scleroderma. The results suggest that cold exposure in such patients may elicit transient reflex coronary vasoconstriction resulting in reversible myocardial ischemia and dysfunction. Chronic recurrent episodes of coronary spasm may lead to focal myocardial fibrosis

  4. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  5. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika; Monbaron, David; Ruiz, Juan; Koehli, Melanie

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, 99m Tc-sestamibi, 201 Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS≥4) was observed in 49 (37%) patients (SSS=4.9±8.4, SDS=2.4±4.7), reversible perfusion defects (SDS≥2) in 40 (30%) patients [SSS=13.3±10.9; SDS=8.0±5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9±11.3; SDS=7.4±1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify these patients with a

  6. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  7. Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan

    2012-01-01

    OBJECTIVESWe wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG).METHODSNinety-two patients with stable angina...... in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects...... that reversible or partly reversible perfusion defects at a preoperative MPS have a high chance of normalized myocardial perfusion assessed by MPS 6 months after operation. Normal perfusion is obtained almost exclusively in territories with reversible ischaemia. Symptoms improved in nearly all patients and LVEF...

  8. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    Science.gov (United States)

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.

  9. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  10. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    International Nuclear Information System (INIS)

    Bobba, K.; Botvinick, E.H.; Sciammarella, M.G.; Starsken, N.F.; Zhu, Y.Y.; Lapidus, A.; Dae, M.W.

    1998-01-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible SPET perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1.25±0.50 on the 4-h images, and of 3.00 on the 24-h images. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50±0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80±0.84 at 4-h to 3.30±0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility at 24 h. Two patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% had recent acute ischemic syndrome, compared with only 13% in group A. Among 11 patients with unstable angina, six had evidence of delayed 24-h reversibility, compared with 2 of 35 patients without clinically acute ischemia. On follow-up, there were seven cardiac

  11. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    Energy Technology Data Exchange (ETDEWEB)

    Bobba, K.; Botvinick, E.H.; Sciammarella, M.G.; Starsken, N.F.; Zhu, Y.Y.; Lapidus, A.; Dae, M.W. [Nuclear Medicine Section, Department of Radiology, Cardiovascular Division, Department of Medicine, and the Cardiovascular Research Institute, University of California, San Francisco (United States)

    1998-05-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible SPET perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1.25{+-}0.50 on the 4-h images, and of 3.00 on the 24-h images. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50{+-}0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80{+-}0.84 at 4-h to 3.30{+-}0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility at 24 h. Two patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% had recent acute ischemic syndrome, compared with only 13% in group A. Among 11 patients with unstable angina, six had evidence of delayed 24-h reversibility, compared with 2 of 35 patients without clinically acute ischemia. On follow-up, there were seven

  12. Reproducibility of quantitative planar thallium-201 scintigraphy: quantitative criteria for reversibility of myocardial perfusion defects

    International Nuclear Information System (INIS)

    Sigal, S.L.; Soufer, R.; Fetterman, R.C.; Mattera, J.A.; Wackers, F.J.

    1991-01-01

    Fifty-two paired stress/delayed planar 201 TI studies (27 exercise studies, 25 dipyridamole studies) were processed twice by seven technologists to assess inter- and intraobserver variability. The reproducibility was inversely related to the size of 201 Tl perfusion abnormalities. Intraobserver variability was not different between exercise and dipyridamole studies for lesions of similar size. Based upon intraobserver variability, objective quantitative criteria for reversibility of perfusion abnormalities were defined. These objective criteria were tested prospectively in a separate group of 35 201 Tl studies and compared with the subjective interpretation of quantitative circumferential profiles. Overall, exact agreement existed in 78% of images (kappa statistic k = 0.66). We conclude that quantification of planar 201 Tl scans is highly reproducible, with acceptable inter- and intraobserver variability. Objective criteria for lesion reversibility correlated well with analysis by experienced observers

  13. The incidence and functional consequences of RT-associated cardiac perfusion defects

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Yu Xiaoli; Prosnitz, Robert G.; Zhou Sumin; Hardenbergh, Patricia H.; Blazing, Michael; Hollis, Donna; Lind, Pehr; Tisch, Andrea; Wong, Terence Z.; Borges-Neto, Salvador

    2005-01-01

    Purpose: Radiation therapy (RT) for left-sided breast cancer has been associated with cardiac dysfunction. We herein assess the temporal nature and volume dependence of RT-induced left ventricular perfusion defects and whether these perfusion defects are related to changes in cardiac wall motion or alterations in ejection fraction. Methods: From 1998 to 2001, 114 patients were enrolled onto an IRB-approved prospective clinical study to assess changes in regional and global cardiac function after RT for left-sided breast cancer. Patients were imaged 30 to 60 minutes after injection of technetium 99m sestamibi or tetrofosmin. Post-RT perfusion scans were compared with the pre-RT studies to assess for RT-induced perfusion defects as well as functional changes in wall motion and ejection fraction. Two-tailed Fisher's exact test and the Cochran-Armitage test for linear trends were used for statistical analysis. Results: The incidence of new perfusion defects 6, 12, 18, and 24 months after RT was 27%, 29%, 38%, and 42%, respectively. New defects occurred in approximately 10% to 20% and 50% to 60% of patients with less than 5%, and greater than 5%, of their left ventricle included within the RT fields, respectively (p = 0.33 to 0.00008). The rates of wall motion abnormalities in patients with and without perfusion defects were 12% to 40% versus 0% to 9%, respectively; p values were 0.007 to 0.16, depending on the post-RT interval. Conclusions: Radiation therapy causes volume-dependent perfusion defects in approximately 40% of patients within 2 years of RT. These perfusion defects are associated with corresponding wall-motion abnormalities. Additional study is necessary to better define the long-term functional consequences of RT-induced perfusion defects

  14. Clinical investigation of large perfusion defect cases with 201Tl exercise myocardial scintigraphy

    International Nuclear Information System (INIS)

    Morota, Motoi; Kobayashi, Yasuhiko

    1999-01-01

    We investigated retrospectively the clinical significance of large perfusion defect on 201 Thallium myocardial scintigraphy from the records of 833 patients during the past 3 years from 1991 to 1994. The patients were divided into 3 groups according to the extent of perfusion defect; cases with normal perfusion (n=561), with small perfusion defect (n=211) and with large perfusion defect (n=61). We found that the proportions of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in myocardial disease (MD; hypertrophic cardiomyopathy, dilated cardiomyopathy, and post myocarditis combined) (P 201 Thallium myocardial scintigraphy and that complication of diabetes mellitus and clinical symptoms may be useful in differentiating IHD from MD. (author)

  15. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    Science.gov (United States)

    Bobba, K; Botvinick, E H; Sciammarella, M G; Starsken, N F; Zhu, Y Y; Lapidus, A; Dae, M W

    1998-05-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible single-photon emission tomography (SPET) perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients (82%) 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients (17%) demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1. 25+/-0.50 on the 4-h images, and of 3.00 on the 24-h images, where normal is 4. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50+/-0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80+/-0.84 at 4-h to 3.30+/-0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours, with a mean score improvement of 4. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility with a score of 4 at 24 h. Two (4%) patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% (6/8) had recent acute ischemic syndrome, compared with only 13% (5/38) in group A (P = 0. 001). Among 11 patients with unstable angina

  16. Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

    International Nuclear Information System (INIS)

    Zakavi, Seyed Rasoul; Taherpour, Mehdi; Moossavi, Zohreh; Sadeghi, Ramin; Kakhki, Vahidreza Dabbagh; Rokni, Haleh

    2013-01-01

    Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. One hundred thirty consecutive asymptomatic patients, aged 35-65 years with type 2 diabetes mellitus and with no history of CAD and no cardiac symptoms were recruited in the study. Echocardiography, electrocardiography (ECG), routine laboratory tests and exercise treadmill test (ETT) were performed and patients with weakly positive or negative ETT underwent Dipyridamole MPI. Patients with positive ETT were referred to coronary angiography. Patients were followed for at least 17 months (mean 21.7 months) and any cardiac event was recorded. We studied 81 female and 49 male patients with mean age of 51.8 years. Negative, weakly positive and positive ETT result was noted in 74.3%, 15% and 10.7% respectively. 75% of patients with positive ETT had coronary artery disease in angiography. Gated myocardial perfusion SPECT was done in 106 patients. MPI showed reversible defect in 26.9% of the patients with a mean summed stress score of 3.3±1.8. Follow up completed in 112 patients and only one patient with abnormal MPI underwent coronary angiography followed by PTCA. No cardiac death, MI, UA or hospital admission occurred among our patients during follow up (17-26 months). Mean stress end diastolic volume (EDV) was significantly higher in patients with reversible defect compared to patients without reversible defect based on MPI findings (62.0±31.6 Vs 48.5±18.4 ml, P=0.04). Blood glucose and HbA1c were significantly higher in patients with ischemia compared to patients without ischemia (P<0.05). Meanwhile the ratio of TG to HDL was 6.06±3.2 in ischemic patients compared to 4.8±2.3 in normal

  17. Dynamic CT of portal hypertensive gastropathy: significance of transient gastric perfusion defect sign

    International Nuclear Information System (INIS)

    Kim, T.U.; Kim, S.; Woo, S.K.; Lee, J.W.; Lee, T.H.; Jeong, Y.J.; Heo, J.

    2008-01-01

    Aim: To evaluate the 'transient gastric perfusion defect' sign as a way of diagnosing portal hypertensive gastropathy (PHG) on multidetector computed tomography (CT). Materials and methods: Ninety-two consecutive patients with cirrhosis underwent three-phase CT and endoscopy. Endoscopy was performed within 3 days of the CT examination. As controls, 92 patients without clinical evidence of chronic liver diseases who underwent CT and endoscopy were enrolled; the findings at endoscopy were used as a reference standard for patients with PHG. Two radiologists who were unaware of the results of the endoscopy retrospectively interpreted the CT images. PHG was diagnosed on dynamic CT if the transient gastric perfusion defect sign was present. The transient gastric perfusion defect was defined as the presence of transient, segmental or subsegmental hypo-attenuating mucosa in the fundus or body of the stomach on hepatic arterial imaging that returned to normal attenuation on portal venous or equilibrium-phase imaging. The frequency of the transient gastric perfusion defect sign was compared between these two groups using Fisher's exact test. The frequency, sensitivity, specificity, positive predictive values, and negative predictive values of the transient gastric perfusion defect sign were also compared between patients with PHG and without PHG in the cirrhosis group. Results: Nine patients of 92 patients with cirrhosis were excluded because of previous procedure or motion artifact; the remaining 83 patients with cirrhosis were evaluated. In the cirrhosis group, 40 (48.1%) of 83 patients showed the transient gastric perfusion defect sign. In the control group, none of the 92 patients showed the transient gastric perfusion defect sign. In the cirrhotic group, the frequency of the transient gastric perfusion defect sign was significantly higher in the patients with PHG (75%, 36/48) than in patients without PHG (11.4%, 4/35). The sensitivity, specificity, positive predictive

  18. ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease

    International Nuclear Information System (INIS)

    Galli, M.; Marcassa, C.; Bosimini, E.; Zoccarato, O.; Comazzi, F.; Giannuzzi, P.

    1997-01-01

    To investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor ≥1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0.001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion. (orig./MG). With 5 figs., 4 tabs

  19. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae

    2005-01-01

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 ± 8.5%, range:3 ∼ 35%) and mild to moderate severity (-71 ± 42.7%, range:-217 ∼ -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome

  20. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-02-15

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 {+-} 8.5%, range:3 {approx} 35%) and mild to moderate severity (-71 {+-} 42.7%, range:-217 {approx} -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

  1. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    Science.gov (United States)

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  2. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  3. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  4. Role of adenosine 99MTc sestamibi myocardial perfusion spect in evaluation of symptomatic hypertensives with recent onset left bundle branch block

    International Nuclear Information System (INIS)

    Padma, S.; Sundaram, P.S.; Zachariah, M.; Hariads, K.K.

    2004-01-01

    Objectives: Adenosine pharmacological stress Myocardial Perfusion Imaging (AMPI) is the preferred imaging modality for IHD evaluation in pts with Left Bundle Branch Block (LBBB). Good prognosis has been reported in recent onset LBBB pts with normal MPI. Our aim was to evaluate the utility and analyze the predictive value of SestaMIBI AMPI in symptomatic recent onset LBBB hypertensives for coronary artery disease evaluation. Methods: 29 hypertensive pts, age range 36-72yrs, mean 54+ 6 yrs, M:F- 21:8 with recent onset complete LBBB, under evaluation for typical/atypical angina who had AMPI between Nov 02-Nov 03, were retrospectively analyzed. LBBB was diagnosed ECG wise if there is prolonged QRS complex i.e. 0.125sec or more in sinus/supraventricular rhythm, a QS or rS complex in lead 1, and an R-wave peak time of 0.06sec in leads 1, V5 or V6 with no Q wave in same lead. Pts with prior Myocardial Infarct / revasularisation, pacemaker induced LBBB were excluded. Single day 6 min. Adenosine infusion Stress-rest 99m Tc MIBI gated MPI was performed with a dual head variable angle Gamma Camera at 76-degree angle. Coronary Angiogram (CAG) correlation was available in 24 pts. Results: Myocardial perfusion SPECT images were assessed visually and by a 20-segment model. Location, extent and severity of the LV perfusion defects were evaluated. 6/29 pts (20.7%) had normal stress-rest perfusion in all LV segments.12 (41.4%) had isolated septal fixed defect with normal perfusion in rest of the segments.3 pts (10.3%)showed isolated reversible septal defects while 8(27.6%) had reversible septal defects with reversible defects in other LV segments also. Pts with fixed septal perfusion defect showed moderate to good septal wall thickening in gated SPECT images. While all pts with multiple reversible perfusion defects had angiographically proven coronary artery disease (i.e. 3pts had LAD lesion, 2 had Triple vessel and 3 showed double vessel lesions), 1 out of 3 pts with isolated

  5. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    Energy Technology Data Exchange (ETDEWEB)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui [Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr {approx} 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1{approx}9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI.

  6. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    International Nuclear Information System (INIS)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui

    2007-01-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr ∼ 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1∼9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI

  7. Extended Islanded Reverse Sural Artery Flap for Staged Reconstruction of Foot Defects Proximal to Toes

    International Nuclear Information System (INIS)

    Yousaf, M.A.; Abidin, Z.U.; Khalid, K.; Haq, A.U.; Tarar, F.A.; Asif, M.U.; Tarar, M.N.

    2018-01-01

    To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Study Design:Case series. Place and Duration of Study:Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Methodology:Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Results:Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 +12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Conclusion:Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area. (author)

  8. Extended Islanded Reverse Sural Artery flap for Staged Reconstruction of Foot Defects Proximal to Toes.

    Science.gov (United States)

    Yousaf, Muhammad Amin; Abidin, Zain Ul; Khalid, Kamran; Haq, Ata Ul; Khalid, Farrukh Aslam; Tarar, Faraz Ahmad; Asif, Muhammad Umar; Tarar, Moazzam Nazeer

    2018-02-01

    Obective:To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Case series. Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area.

  9. Significance of abnormal myocardial perfusion scintigraphy in young adult patients with SLE

    International Nuclear Information System (INIS)

    Zakavi, S.R.; Kakhki, V.R.D.; Sadeghi, R.; Jokar, M.H.; Khazaei, G.

    2009-01-01

    Detection of subclinical coronary artery disease (CAD) is a potential challenge in patients with systemic lupus erythematosus (SLE) and it is suggested that myocardial perfusion single photon emission computerized tomography (SPECT) is more sensitive than exercise test in this setting. However, the significance of perfusion abnormalities in SLE patients is not well known. In this study, we evaluated the prognostic significance of myocardial perfusion defects in patients with SLE. Patients with proven diagnosis of SLE admitted to the hospital due to noncardiac problems with no history of CAD were studied. All patients underwent 99m Tc-methoxyisobutylisonitrile (MIBI) myocardial perfusion scan using dipyridamole as pharmacological stress. All patients were followed up by reviewing patients file in lupus clinic and any minor or major cardiac events were recorded. Eighteen female and two male patients with mean age of 28.2±12.05 years were included. Six patients had mild reversible perfusion defects with mean summed difference score of 2.5±1.0. Pattern of reverse redistribution (reverse fill-in) was noted in three patients. Eleven patients had normal myocardial perfusion. Hypokinesia was noted in three patients on gated images. One patient with abnormal perfusion died 21 days after imaging due to on-cardiac cause. Nineteen patients were followed for a mean time of 39.2±16.0 months. No major or minor cardiac events were noted during follow-up. Three patients (one with abnormal perfusion) had at least one readmission during follow-up period. Our study showed that myocardial perfusion abnormalities are fairly frequent in SLE patients but the defects are generally mild and do not advocate an adverse prognosis. (author)

  10. Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability

    International Nuclear Information System (INIS)

    Kiat, H.; Berman, D.S.; Maddahi, J.; De Yang, L.; Van Train, K.; Rozanski, A.; Friedman, J.

    1988-01-01

    Twenty-one patients were studied who underwent thallium-201 stress-redistribution single photon emission computed tomography (SPECT) both before and after coronary artery bypass grafting (n = 15) or transluminal coronary angioplasty (n = 6). All patients underwent thallium imaging 15 min, 4 h and late (18 to 72 h) after stress as part of the preintervention thallium-201 scintigram. In a total of 201 tomographic myocardial segments with definite post-stress thallium-201 perfusion defects in which the relevant coronary arteries were subsequently successfully reperfused, the 4 h redistribution images did not predict the postintervention scintigraphic improvement: 67 (85%) of the 79 4 h reversible as well as 88 (72%) of the 122 4 h nonreversible segments improved (p = NS). The 18 to 72 h late redistribution images effectively subcategorized the 4 h nonreversible segments with respect to postintervention scintigraphic improvement: 70 (95%) of the 74 late reversible segments improved after intervention, whereas only 18 (37%) of the 48 late nonreversible segments improved (p less than 0.0001). The frequency of late reversible defects and the frequency of postrevascularization improvement of late nonreversible defects are probably overestimated by this study because of referral biases. The cardiac counts and target to background ratios from late redistribution studies resulted in satisfactory cardiac images for visual interpretation. For optimal assessment of the extent of viable myocardium by thallium-201 scintigraphic studies, late redistribution imaging should be performed when nonreversible defects are observed on 4 h redistribution images

  11. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  12. Detection of myocardial stunning with gated SPECT and its relationship with location, extension and severity of perfusion defects induced by exercise or pharmacologic stress

    International Nuclear Information System (INIS)

    Mut, F.; Beretta, M.; Vidal, I.; Rener, A.; Alonso, O.

    2002-01-01

    Aim: To investigate the relationship between transient ventricular dysfunction detected by gated SPECT with the location, extension and severity of ischemic areas in patients with reversible perfusion defects. Material and Methods: We retrospectively studied 83 patients (61±11 yrs., 61 men, 27 with previous MI) submitted for coronary artery disease (CAD) evaluation with 99mTc-MIBI gated SPECT using a 2-day protocol whose perfusion imaging pattern had been reported positive for myocardial ischemia. Stress test was exercise in 54 cases, dipyridamole in 28 and dobutamine in 1. Previous work from our group demonstrated up to 12% change in LVEF from rest to post-stress in a population with low likelihood of CAD and a normal perfusion pattern. Thus, according to % variation of left ventricular ejection fraction (LVEF) from rest to post-stress we further divided the population into 2 subgroups, (A) with less than 12% change in LVEF (n=56) and (B) with more than 12% negative variation (n=27). For evaluation of perfusion, a simplified 7-segment division of the myocardium was used and a combined ischemic score was obtained by multiplying the number of segments with reversible defects by the 1-4 assigned severity score. Results: There was no significant difference between the two groups regarding age, gender, stress result (clinical or ECG), number of fixed perfusion defects or rest LVEF. Dipyridamole test was more frequent among patients of group B. Post-stress LVEF was 49±14% for group A and 41±15% for group B, p=0.0125. Combined ischemic score was 6.82±6.5 vs. 11.96±12 respectively, p=0.014. In patients of group A, defects corresponding to the right coronary territory were more frequent, while the left descending artery territory was more commonly affected in group B patients, however this was not statistically significant. Left circumflex territory was equally affected in both groups. Conclusion: Transient ventricular dysfunction after a stress test can be

  13. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  14. Analysis of hip perfusion at early and reversible stages of aseptic hip necrosis

    International Nuclear Information System (INIS)

    Predic, P.; Dodig, D.; Karner, I.

    2002-01-01

    Aim: A proper early diagnosis of aseptic hip necrosis is very important for further therapy.Since there has always been a question of the amount of perfusion in hips at different stages of aseptic hip necrosis we tried to impartially examine the perfusion in hips at early and reversible stages of aseptic hip necrosis. Material and Methods:Study included 143 patients with aseptic hip necrosis.The 550-740 MBq of Tc-99m-DPD were on bolus injected.All patients were subjected to 3-phase scintigraphy of hips and quantitative calculation of relative perfusion in the artery phase (3T) at early and repeated at reversible stages of aseptic hip necrosis. Results: At the early stage of aseptic hip necrosis the obtained 3T was decreased from 0.94-0.69 (3T=0.80).Scintigrams showed a moderate increase or diffuse accumulation. At the reversible stages we obtained 3T decreased from 0.92-0.71 (3T=0.79) thus evidencing hypoperfusion.Scintigrams showed an diffuse increased accumulation. Conclusion: With the aseptic hip necrosis quantitative analysis of perfusion in the artery phase-3T indicates that the perfusion is decreased at all stages of the process which however shows a significantly falling trend with the progress of the disease

  15. Myocardial perfusion imaging with thalium 201 during and after exercise in patients with coronary heart

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, P B; Villacorta, E V; Monzon, O P; Torres, Jr, J F; Guzman, S V

    1977-07-01

    A unique, non-invasive technique for the evaluation of the regional myocardial perfusion of patients with coronary heart disease has been developed. This entails the use of radionuclide, like thallium (Tl-201), which concentrates in the normal myocardium, leaving areas of ischemia or scarring or ''cold'' perfusion defects. Myocardial perfusion imaging in conjunction with graded exercise testing significantly increases the positivity of the stress test alone among patients with classic angina from 80% to 95%. It gives invaluable information as to the site and extent of the lesion and its reversibility. Among the patients with ECG Q waves indicative of previous infarction, image defects were detected in 93.7%; reversible ischemia co-existing with the infarction was also demonstrated.

  16. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    1986-01-01

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined

  17. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    International Nuclear Information System (INIS)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P.; Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Holt, Wik L. ten

    2006-01-01

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of ≥3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  18. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P. [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Verberne, Hein J.; Eck-Smit, Berthe L.F. van [Academic Medical Center Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); Holt, Wik L. ten [Amstelland Hospital, Department of Cardiology, Amstelveen (Netherlands)

    2006-12-15

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of {>=}3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  19. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  20. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.; Haines, J.E.; Specht, H.D.; Bennett, R.M.; Kloster, F.E.

    1984-01-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment, major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined

  1. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  2. Improvement of myocardial perfusion status in response to indian vedic breathing

    International Nuclear Information System (INIS)

    Anand, Y.N.I.; Muthu, G.S.

    2004-01-01

    Introduction: Yoga is the buzz word all over the world today. Amidst their busy schedule, people tend to ignore their personal health. Management of various disorders, especially those involving interventions, surgical or radiological, is very expensive. The Indian Vedic Exercises, of which Pranaayaama is one, emphasize on prevention of the diseases in order to keep the individual in good health. It is equally applicable to those who have already suffered from various disorders and in whom both improvement and/or avoidance of further deterioration are required. However, no Objective assessment of the disease status in response to these exercises has been reported so far. Objectives: This pilot study has been undertaken on patients with reversible myocardial perfusion defects to Objectively monitor the improvements in the myocardial perfusion in response to a breathing exercise, Pranayama, a breathing technique prescribed in the Indian Vedic Sciences. Methods: Two patients who were found to have reversible myocardial perfusion defects were taken up in this study. These defects were diagnosed from the myocardial perfusion SPECT done in stressed (on Tread Mill) and resting states with 99m Technetium labeled MIBI.These patients were taught the pranayama technique which is done for about 30 minutes every day. At the end of four months from the commencement of this technique, the myocardial perfusion SPECT studies were repeated. Details of the exercise in the form of a CD are available on request. Results: Overall good improvements were observed in all the quantitative parameters in the TMT and SPECT studies in the studies done after the pranayama procedures in both the patients. Perfusion defects seen in the stress images of the initial studies have almost completely reversed in the stress images of the later study. Patients are asymptomatic and are leading a comfortable life. Conclusion: This is only a study of two cases to Objectively evaluate the effects of pranayama

  3. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  4. Detection of myocardial ischemia of hypertrophic cardiomyopathy with gated 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Du Minghua; Gao Ling

    2010-01-01

    Objective: To evaluate the value of gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in detection of myocardial ischemia in hypertrophic cardiomyopathy. Methods: Sixty-nine patients with clinically proven hypertrophic cardiomyopathy were divided into 2 groups using coronary angiogram as 'gold standard': positive group (n=19, narrowing ≥ 50%) and negative group (n=50, narrowing 99 Tc m -MIBI myocardial perfusion imaging was performed and positive in all 69 patients (41 males, 28 females, aged 35-75 years). Comparative analysis between the two groups was carried out using t-test. Results: In the positive group, reversible and irreversible perfusion defects were detected in 9 and 10 patients, respectively. Left ventricular ejection fraction (LVEF) increased to (69.1 ± 2.8)% in 8 patients and decreased to (42.8 ± 2.1)% in 11 patients. In the negative group, reversible and irreversible perfusion defects were found in 37 and 13 patients, respectively. LVEF increased to (70.8 ± 4.0)% in 38 patients and decreased to (48.9 ± 2.7)% in 12 patients. The values of ischemic area, severity and extent of perfusion defect, and LVEF were significantly different between the two groups (t=9.28, 16.51, 2.65; P 99 Tc m -MIBI myocardial perfusion imaging is valuable in assessing patients with hypertrophic cardiomyopathy. Detection for the presence or absence of coexisting coronary artery disease and myocardial ischemia has an important prognostic indication and management indication for these patients. (authors)

  5. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young [Dept. of Radiology, Chonbuk National University Medical School and Hospital, Research Institute of Clinical Medicine, Jeonju (Korea, Republic of); Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Hwang, Hye Jeon [Dept. of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Young Kyung [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of)

    2014-04-15

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  6. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    International Nuclear Information System (INIS)

    Kim, Eun Young; Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min; Hwang, Hye Jeon; Lee, Young Kyung

    2014-01-01

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  7. CT perfusion imaging in the management of posterior reversible encephalopathy

    International Nuclear Information System (INIS)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L.

    2004-01-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  8. Impairment of myocardial perfusion in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Acar, P.; Montalembert, M. de

    2003-01-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 ± 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  9. Lung scans with significant perfusion defects limited to matching pleural effusions have a low probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Datz, F.L.; Bedont, R.A.; Taylor, A.

    1985-01-01

    Patients with a pleural effusion on chest x-ray often undergo a lung scan to exclude pulmonary embolism (PE). According to other studies, when the scan shows a perfusion defect equal in size to a radiographic abnormality on chest x-ray, the scan should be classified as indeterminate or intermediate probability for PE. However, since those studies dealt primarily with alveolar infiltrates rather than pleural effusions, the authors undertook a retrospective study to determine the probability of PE in patients with pleural effusion and a matching perfusion defect. The authors reviewed 451 scans and x-rays of patients studied for suspected PE. Of those, 53 had moderate or large perfusion defects secondary to pleural effusion without other significant (>25% of a segment) effusion without other significant (>25% of a segment) defects on the scan. Final diagnosis was confirmed by pulmonary angiography (16), thoracentesis (40), venography (11), other radiographic and laboratory studies, and clinical course. Of the 53 patients, only 2 patients had venous thrombotic disease. One patient had PE on pulmonary angiography, the other patient had thrombophlebitis on venography. The remainder of the patients had effusions due to congestive heart failure (12), malignancy (12), infection (7), trauma (7), collegen vascular disease (7), sympathetic effusion (3) and unknown etiology (3). The authors conclude that lung scans with significant perfusion defects limited to matching pleural effusions on chest x-ray have a low probability for PE

  10. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    Science.gov (United States)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  11. Myocardial perfusion abnormality and chest pain in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1991-01-01

    To investigate the role of myocardial ischemia in the development of chest pain in patients with hypertrophic cardiomyopathy (HCM), exercise stress (Ex) redistribution myocardial single photon emission CT's (SPECT's) with thallium-201 (Tl) were obtained in 27 patients with HCM. In all patients, coronary arteries were normal arteriographically. Patients were classified into NYHA Class I, II and III according to the frequency and severity of the chest pain during daily life. In these 3 groups, age, sex and intraventricular septal thickness measured by echocardiography were not different. Types of myocardial perfusion obtained by myocardial SPECT's were divided into 5: (1) normal perfusion, (2) no perfusion defect with abnormal myocardial Tl washout rate (WOR) during 3 hours (<30%) [Def(-)/WORabn], (3) reversible perfusion defect (RD), (4) fixed defect with abnormal WOR (FD/WORabn), and (5) fixed defect with normal WOR (FD/WORnl). In 14 patients of Class I, 9 patients (64%) showed normal perfusion but the rest showed perfusion abnormality (def(-)/WORabn in 3 and RD in 2). In Class II and III, all patients showed perfusion abnormalities of RD, FD/WORabn or FD/WORnl. As the functional class progressed from Class II to III, the ratio of fixed defect (both WORnl and WORabn) to RD increased, but it was not statistically significant. In 2 patients in whom Ex SPECT's were repeated because of the progression of the chest pain, the severity of the perfusion abnormality also progressed. Perfusion abnormalities were observed most frequently in anterior (35%), then inferior/posterior (20%) and septal wall (18%). The frequency of Ex induced ECG abnormalities (ST-depression or T wave changes) increased as the NYHA Class progressed (Class III vs I p<0.05). These findings suggested the following: chest pain in patients with HCM relates to the myocardial ischemia which may originate in the myocardial small arteries, and when the lesions progress myocardial necrosis may ensue. (author)

  12. Prognostic significance of large perfusion defects on thallium-201 myocardial scintigraphy in dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Takata, Jun; Doi, Yoshinori; Chikamori, Taishiro; Yonezawa, Yoshihiro; Hamashige, Naohisa; Kuzume, Osamu; Ozawa, Toshio

    1989-01-01

    To evaluate the prognostic significance of perfusion abnormalities, particularly large defects, in dilated cardiomyopathy (DCM), we performed thallium-201 myocardial scintigraphy and 24-hour ambulatory ECG monitoring in 27 patients. The abnormal scintigraphic patterns and the presence of ventricular tachycardia (VT) were correlated with causes of death during a follow-up period of 30.0±19.4 months. Eight patients had large defects (LD), 11 had multiple small defects (MSD), and eight had no defects (NL). The patients with LD had extensive ventricular akinesis in the region of the perfusion defect, significantly elevated LVEDP (LD 20.6±7.4 mmHg, MSD 15.5±7.6 mmHg, NL 10.3±2.3 mmHg: LD vs NL; p<0.01, MSD vs NL; p<0.05), and reduced ejection fraction (LD 23.9±9.1%, MSD 32.7±7.2%, NL 40.3±7.7%: LD vs MSD; p<0.05, MSD vs NL; p<0.01). VT was detected in 11 patients; among whom three had LD, six had MSD, and two had no defects. Among seven patients who died during follow-up (five of heart failure, one sudden death, and one non-cardiac death), five had LD and two had MSD. There were no deaths among patients without defects. Among 11 patients with VT, only one died suddenly. In conclusion, large scintigraphic defects correlated well with severe LV dysfunction, and this is an important variable in predicting outcomes in DCM. (author)

  13. Assessment of relationship between regional perfusion and ventricular function in patients with severely depressed ejection fraction

    International Nuclear Information System (INIS)

    Teresinska, A.; Konieczna, S.; Szumilak, B.; Gosiewska-Marcinkowska, E.; Potocka, J.

    1998-01-01

    Patients with low ventricular (LV) ejection fraction (EF) and with regional or global LV dysfunction, considered for myocardial revascularization, are often submitted to myocardial perfusion study to ptrove perfusion preserved and to approximate viability. The aim of this work is to evaluate, to what extent SPECT with Tc-99m-MIBI (SPECT-MIBI) additionally differentiatesa and enlarges the information on LV contractility achieved from radioisotopic ventriculography (RNV). Seventy-three patients with EF=0.11-0.35 (mean: 0.26 ± 0.06, calculated from RNV) were studied. Planar gated RNV and SPECT-MIBI were performed within 2 months (mean: 15 ± 14 days). RNV, after in vivo red cells labeling with Tc-99m, was recorded in rest in LAO45 and RAO30 views. Global EF and contractility of 5 regions (anterior, posterior, lateral walls, septum and apex) were evaluated. Assessment was performed by means of LV in 'cine' mode,m ED and ES outlines and amplitude-phase images. Regional contractility abnormalities were classified as dyskinesis, akinesis and hypokinesis. SPECT-MIBI was performed in rest and stress. Perfusion abnormalities in 5 above mentioned regions was classified as large (more intense than 50% of myocardial maximum) or small persistent defects (DEFpers), large or small partially reversible defects (DEFpart-rev), large or small completely reversible defects (DEFrev). Hypokinesis was detected in 23-35 regions (65%) , dyskinesis - in 63 (17%), akinesis - in 37 (10%), normokinesis - in 27 (7%). In dyskinetic regions, there existed large DEFpers (79%) or large DEFpart-rev (21%). In akinetic regions, there also existed large DEFpers (68%) or large DEFpart-rev (32%). In hypokinetic regions, there were no perfusion defects (31% of regions), small DEFpers, DEFrev and DEFpart-rev (42%) and also large DEFpers (27%). In most of normokinetic regions, different types of perfusion defects were observed (large DEFpers existed in 26% of regions). In summary: In dyskinetic and akinetic

  14. Repair of segmental bone defect using Totally Vitalized tissue engineered bone graft by a combined perfusion seeding and culture system.

    Directory of Open Access Journals (Sweden)

    Lin Wang

    Full Text Available BACKGROUND: The basic strategy to construct tissue engineered bone graft (TEBG is to combine osteoblastic cells with three dimensional (3D scaffold. Based on this strategy, we proposed the "Totally Vitalized TEBG" (TV-TEBG which was characterized by abundant and homogenously distributed cells with enhanced cell proliferation and differentiation and further investigated its biological performance in repairing segmental bone defect. METHODS: In this study, we constructed the TV-TEBG with the combination of customized flow perfusion seeding/culture system and β-tricalcium phosphate (β-TCP scaffold fabricated by Rapid Prototyping (RP technique. We systemically compared three kinds of TEBG constructed by perfusion seeding and perfusion culture (PSPC method, static seeding and perfusion culture (SSPC method, and static seeding and static culture (SSSC method for their in vitro performance and bone defect healing efficacy with a rabbit model. RESULTS: Our study has demonstrated that TEBG constructed by PSPC method exhibited better biological properties with higher daily D-glucose consumption, increased cell proliferation and differentiation, and better cell distribution, indicating the successful construction of TV-TEBG. After implanted into rabbit radius defects for 12 weeks, PSPC group exerted higher X-ray score close to autograft, much greater mechanical property evidenced by the biomechanical testing and significantly higher new bone formation as shown by histological analysis compared with the other two groups, and eventually obtained favorable healing efficacy of the segmental bone defect that was the closest to autograft transplantation. CONCLUSION: This study demonstrated the feasibility of TV-TEBG construction with combination of perfusion seeding, perfusion culture and RP technique which exerted excellent biological properties. The application of TV-TEBG may become a preferred candidate for segmental bone defect repair in orthopedic and

  15. Myocardial viability in cases with persistent perfusion defects on the dipyridamole thallium-201 scintigram. A comparative study with autopsy findings

    International Nuclear Information System (INIS)

    Nakayama, Masafumi; Mashima, Saburo; Ohkawa, Shin-ichiro; Tanno, Munehiko; Yamada, Hideo.

    1996-01-01

    The aim of this study was to assess the incidence of myocardial infarction among persistent perfusion defects in dipyridamole-stress thallium scintigraphy by inspecting autopsied hearts and to evaluate whether the regional thallium activity of a scintigraphic defect can predict the presence of infarction. Autopsied hearts were compared with dipyridamole myocardial scintigrams undertaken during life in 27 patients (mean age 85±8 years). The time interval from stress testing until death was 428±351 days. Regional thallium uptake of delayed perfusion defect was calculated on the short axis images. The grade of regional myocardial fibrosis in autopsy specimens was also quantified to correlate with the corresponding regional thallium uptake. In 6 of 15 (40%) regions with persistent defects on the scintigram, myocardial infarction was not found at autopsy. Regional thallium-201 uptake of delayed defects < 50% diagnosed infarction with a sensitivity of 82% and a specificity of 80%. A linear correlation (r=-0.67) was observed between percent thallium-201 uptake and the degree of myocardial fibrosis. In conclusion, perfusion defects at 4-hour imaging in dipyridamole-stress testing may overestimate the presence of myocardial infarction and regional thallium-201 activity is helpful in distinguishing between defects with and without infarction. (author)

  16. From monster to twin reversed arterial perfusion: a history of acardiac twins.

    Science.gov (United States)

    Obladen, Michael

    2010-05-01

    A human being born without heart and head, i.e., the acardius/acranius malformation, has been described since antiquity. Superstition and fear made it a mystical disorder, a sign of God's wrath. The inquisition ruled that acranic infants should not be baptized and located the soul in the brain. Acardia was not associated with twin gestation until the reports of Mery in 1720 and Winslow in 1740. In 1850, Meckel identified the pathogenetic mechanism as reversed perfusion due to large arterio-arterial and veno-venous anastomoses; he believed the heart would fail to develop or arrest during development, and the acardiac fetus would be maintained by arterial perfusion from the pump twin. In 1859, Claudius articulated that after normal initial development, the heart degenerates when reversed flow in the aorta leads to thrombosis. Today, it is assumed that both mechanisms may exist. With the advent of prenatal ultrasound diagnosis and radiofrequency ablation of the acardiac twin's circulation, it became possible to save the pump twin.

  17. Altered myocardial perfusion during dobutamine stress testing in silent versus symptomatic myocardial ischaemia assessed by quantitative MIBI SPET imaging

    International Nuclear Information System (INIS)

    Elhendy, A.; Geleijnse, M.L.; Roelandt, J.R.T.C.; Cornel, J.H.; Domburg, R.T van; Reijs, A.E.M.; Nierop, P.R.; Fioretti, P.M.

    1996-01-01

    The aim of the study was to compare the extent and severity of reversible underperfusion in silent versus painful myocardial ischaemia during the dobutamine stress test. A consecutive series of 85 patients with significant coronary artery disease and reversible perfusion defects on technetium-99m methoxyisobutylisonitrile single-photon emission tomography performed at rest and during high-dose dobutamine stress (up to 40 μg kg -1 min -1 ) were studied. The left ventricle was divided into six segments. An ischaemic perfusion score was derived quantitatively by subtracting the rest from the stress defect score. Patients with multivessel disease had a higher ischaemic score (610±762 vs 310±411, P<0.05) and a higher number of reversible perfusion defects (2.1±1.2 vs 1.1±0.8, P<0.01) than patients with single-vessel disease. Typical angina occurred in 37 patients (44%) during the test. There was no significant difference between patients with and patients without angina with respecft to age, gender, peak rate-pressure product, prevalence of previous myocardial infarction, diabetes mellitus, multivessel disease or number of stenotic coronary arteries. Stress, rest and ischaemic scores as well as the number and distribution of reversible defects were not different in patients with and patients without angina. Patients with angina more frequently had a history of typical angina before the test (43% vs 17%, P<0.01) and ST-segment depression during the test (54% vs 25%, P<0.01). It is concluded that in patients with coronary artery disease and ischaemia detected by dobutamine scintigraphy, the extent and severity of coronary artery disease and myocardial perfusion abnormalities are similar with or without angina during stess testing. (orig.)

  18. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  19. Application of Three-Class ROC Analysis to Task-Based Image Quality Assessment of Simultaneous Dual-Isotope Myocardial Perfusion SPECT (MPS)

    OpenAIRE

    He, Xin; Song, Xiyun; Frey, Eric C.

    2008-01-01

    The diagnosis of cardiac disease using dual-isotope myocardial perfusion SPECT (MPS) is based on the defect status in both stress and rest images, and can be modeled as a three-class task of classifying patients as having no, reversible, or fixed perfusion defects. Simultaneous acquisition protocols for dual-isotope MPS imaging have gained much interest due to their advantages including perfect registration of the 201Tl and 99mTc images in space and time, increased patient comfort, and higher...

  20. Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Kim, Jeong Ho; Hwang, Kyung Hoon; Choi, In Suck; Choi, Soo Jin; Choe, Won Sick [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of)

    2010-06-15

    The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EMG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

  1. Diagnosis of severe and extensive coronary artery disease using gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Lee, Hyoung Woo; Won, Kyu Chang; Park, Jong Sun; Sin, Dog Gu; Kim, Young Jo; Shim, Bong Sub [College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

    1999-07-01

    Left ventricular volumes and ejection fractions constitute important informations in the diagnosis and prognosis of cardiac disease. Aim of the study is to verify if the assessment of left ventricular function and perfusion together by gated myocardial perfusion SPECT is useful for diagnosing severe and extensive CAD. We examined 27 consecutive patients (17 males and 10 females, mean age : 60.1 years) who underwent two day rest/stress Tc-99m MIBI gated SPECT. Stress was done with adenosine. Post-stress gated SPECT was done at 1 hour after an injection of Tc-99m MIBI (740 MBq). All patients underwent coronary angiography after gated SPECT within 1 month. We divided them three groups with single vessel disease, double vessel disease and triple vessel disease or severe proximal left coronary artery stenosis. Extent of Defect (ED), Reversibility of Extent (RE), Severity of Defect (SD) and Severity of Reversibility (SR) were calculated by CEqual program. Post-stress LVEF, Rest LVEF, End-diastolic volume(EDV), End-systolic volume(ESV), Transient Ischemic Dilation (TID) of left ventricle (Post-stress EDV/Rest EDV) were calculated using gated SPECT quantification program. Left ventricle is divided with 18 segments and wall motion was scored (normal=0, mild hypokinesia =1, severe hypokinesia =2, akinesia =3 and dyskinesia =4), and then post-stress summed wall motion score was calculated. Post-stress summed wall motion score and post-stress LVEF were significant differences between three groups ( P <0.01). Extent of defect, Extent of reversibility, Severity of defect and severity of reversibility in Polar map were significant differences between three groups ( P <0.01). Post-stress Transient left ventricular dilatation and test LVEF were not significant differences between three groups ( P > 0.05). The gated SPECT pattern (low post-stress LVEF and post-stress summed wall motion score) add important diagnostic information over ungated perfusion data (high ED, ER and SR and

  2. Reverse re-distribution in the myocardial perfusion scan with 201 Ti

    International Nuclear Information System (INIS)

    Eftekhari, M.; Sadeghi, R.; Fard-Esfahani, A.; Beiki, D.; Fallahi, B.; Saghari, M.

    2004-01-01

    Reverse re-distribution pattern id defined as decreased activity in the myocardium in the rest phase of the myocardial perfusion scan in comparison with the stress images. There are many studies concerning the etiology and clinical significance of this phenomenon in nuclear medicine literature. The dominant idea about etiology of reserve redistribution is early wash out of the radiotracer from the myocardium. There is rather unanimous agreement among researchers about viability of the areas of reverse redistribution and the majority of the studies point to existence of viable tissue in these regions. However from prognostic point of view, this issue is much more controversial. In this review, we tried to summarize the current literature and reach a guideline for practical significance of reverse redistribution in every day work of nuclear medicine specialists

  3. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  4. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  5. Prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Lin JInghui; Zhang Chunli; Nie Tao; Wang Yanfu

    1998-01-01

    Purpose: To evaluate the prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease (CAD). Methods: 69 patients with CAD underwent exercise myocardial perfusing imaging and exercise ECG test. The images of all of them were abnormal. 45 patients were angiographically proved CAD. Follow-up period ranged from 6∼110 months and even longer than 12 months for patients with no cardiac events (CE). Results: CE occurred in 15 patients during the follow-up period. The CE incidence was 8.7% per year. Cox regression analysis revealed that there was a good correlation between the number of myocardial segments with reversible defects and future CE. Comparing the results of 13 patients with small extent irreversible defects with the data obtained from normal subjects reported previously, there was no significant difference between two no-CE rates (x 2 = 0.09, P>0.05). Conclusions: Normal myocardial images and irreversible defects involving rather small areas predicted an excellent prognosis. The better predictor of future CE is the quantity of myocardial segments with reversible defect

  6. Quantification of reversible perfusion abnormality using exercise-stress thallium SPECT before and after coronary revascularization

    International Nuclear Information System (INIS)

    Nagao, Kazuhiko; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1994-01-01

    Reversible myocardial perfusion abnormality was quantified by bull's eye and unfolded surface mapping methods in exercise thallium SPECT before and after coronary revascularization in 47 patients with angina pectoris, including 34 patients with previous myocardial infarction (PMI) and 13 with effort angina (AP). There was no difference in the incidence or extent of myocardial ischemia between the 2 groups before revascularization. However, the ischemic scores were significantly smaller in PMI group preoperatively than the reductions of the ischemic scores after revascularization. The ischemic scores, preoperatively estimated reversible perfusion abnormality was 32%, 69% and 48% of the improvement of the ischemic score (extent score, severity score, and ischemic area, respectively). Using the 3 ischemic scores, the improvement of perfusion abnormality was well predicted in 70-89% of AP patients but 35-57% of PMI patients. Thus, quantitative analysis in stress thallium SPECT is useful for detecting myocardial ischemia and evaluating the effect of coronary revascularization. However, about a half of myocardial viability was underestimated in one third of PMI patients by the conventional exercise-stress thallium SPECT study. (author)

  7. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  8. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection

    Science.gov (United States)

    Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.

    2009-05-01

    The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

  9. The Myocardial Perfusion Scintigraphy in Predicting Risk for Coronary Artery Disease in Patients with Anxiety and Depression Symptoms

    Directory of Open Access Journals (Sweden)

    Billur Çalışkan

    2016-06-01

    Full Text Available INTRODUCTION: An association between psychological factors and cardiovascular disease, has long been suspected. However it is not clear whether chest pain is caused by emotional distress or whether coronary spasms are caused by the onset of coronary artery disease (CAD. We aimed to predict the risk for CAD in patients referred to myocardial perfusion imaging (MPI with chest pain using depression, stress, and anxiety symptoms. METHODS: The emotional status of all patients was evaluated using the Hospital Anxiety and Depression Scale (HADS-A and HADS-D, the State and Trait Anxiety Inventory (STAI-1 and STAI-2, the Perceived Stress Scale (PSS, and the Anxiety Sensitivity Index-3 (ASI. Myocardial perfusion was measured using a 17-segment model and 5-point scoring system (0: normal perfusion; 4: no perfusion. RESULTS: MPI revealed reversible perfusion defects in 24 of 141 patients and no perfusion defects in 117 patients. The STAI-2 and HADS-A and HADS-D scores were significantly higher in patients with myocardial ischemia than in those without (STAI-2: 50.8 ± 7.5 vs. 46.3 ± 7.1, respectively; p = 0.008; HADS-A: 9.5 ± 3.9 vs. 7.8 ± 3.4, respectively; p = 0.033; HADS-D: 8.7 ± 3.0 vs. 7.3 ± 3.0, respectively; p = 0.05. Unadjusted correlation analysis showed that there was statistically significant correlation between reversible perfusion defects and anxiety scores (r=0.186, p= 0.029. DISCUSSION AND CONCLUSION: The patients with symptoms of depression and high-trait anxiety may be at higher risk of myocardial ischemia than patients without such symptoms. Thus, the emotional status of patients should be taken into consideration during clinical evaluation for CAD.

  10. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    Energy Technology Data Exchange (ETDEWEB)

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  11. Reverse Abdominoplasty Flap in Reconstruction of Post-Bilateral Mastectomies Anterior Chest Wall Defect

    Directory of Open Access Journals (Sweden)

    William HC Tiong

    2014-01-01

    Full Text Available Reverse abdominoplasty was originally described for epigastric lift. Since the work by Baroudi and Huger in the 1970s, it has become clear that reverse abdominoplasty application can be extended beyond just aesthetic procedure. Through the knowledge of anterior abdominal wall vascularity, its application had included reconstructive prospect in the coverage of various chest wall defects. To date, reverse abdominoplasty flap has been used to reconstruct unilateral anterior chest wall defect or for larger defect but only in combination with other reconstructive techniques. Here, we presented a case where it is used as a standalone flap to reconstruct bilateral anterior chest wall soft tissue defect post-bilateral mastectomies in oncological resection. In conclusion, reverse abdominoplasty flap provided us with a simple, faster, and satisfactory reconstructive outcome.

  12. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  13. ST-vector orientation and location of myocardial perfusion defects during exercise

    International Nuclear Information System (INIS)

    Simoons, M.L.; Withagen, A.; Vinke, R.; Kooy, P.; Bakker, W.; Erasmus Universiteit, Rotterdam

    1978-01-01

    In 34 patients with chest pain the spatial orientation of the ST-vectors in the exercise electrocardiogramm 30 and 80 msec after the end of QRS were compared with the location of exercise induced local defects of myocardial uptake of 201 Tl. The following results were obtained: 1. The sensitivity and specifity of myocardial perfusion imaging after exercise were the same as those of exercise electrocardiograms; 2. No relation could be observed beween the location of reduced 201 Tl uptake during exercise and the spatial orientation of the ST-vectors. (orig.) [de

  14. CT perfusion during delayed cerebral ischemia after subarachnoid hemorrhage: distinction between reversible ischemia and ischemia progressing to infarction

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, Charlotte H.P. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vos, Pieter C. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Schaaf, Irene C. van der; Velthuis, Birgitta K.; Dankbaar, Jan Willem [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Vergouwen, Mervyn D.I.; Rinkel, Gabriel J.E. [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, PO Box 85500, Utrecht, Utrecht (Netherlands)

    2015-09-15

    Delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH) can be reversible or progress to cerebral infarction. In patients with a deterioration clinically diagnosed as DCI, we investigated whether CT perfusion (CTP) can distinguish between reversible ischemia and ischemia progressing to cerebral infarction. From a prospectively collected series of aSAH patients, we included those with DCI, CTP on the day of clinical deterioration, and follow-up imaging. In qualitative CTP analyses (visual assessment), we calculated positive and negative predictive value (PPV and NPV) with 95 % confidence intervals (95%CI) of a perfusion deficit for infarction on follow-up imaging. In quantitative analyses, we compared perfusion values of the least perfused brain tissue between patients with and without infarction by using receiver-operator characteristic curves and calculated a threshold value with PPV and NPV for the perfusion parameter with the highest area under the curve. In qualitative analyses of 33 included patients, 15 of 17 patients (88 %) with and 6 of 16 patients (38 %) without infarction on follow-up imaging had a perfusion deficit during clinical deterioration (p = 0.002). Presence of a perfusion deficit had a PPV of 71 % (95%CI: 48-89 %) and NPV of 83 % (95%CI: 52-98 %) for infarction on follow-up. Quantitative analyses showed that an absolute minimal cerebral blood flow (CBF) threshold of 17.7 mL/100 g/min had a PPV of 63 % (95%CI: 41-81 %) and a NPV of 78 % (95%CI: 40-97 %) for infarction. CTP may differ between patients with DCI who develop infarction and those who do not. For this purpose, qualitative evaluation may perform marginally better than quantitative evaluation. (orig.)

  15. Effect of thallium-201 blood levels on reversible myocardial defects

    International Nuclear Information System (INIS)

    Nelson, C.W.; Wilson, R.A.; Angello, D.A.; Palac, R.T.

    1989-01-01

    To determine if 201 Tl plasma blood levels correlate with the presence of reversible myocardial defects during exercise testing, 14 patients with stable coronary artery disease underwent two separate exercise 201 Tl stress tests. Between initial and delayed imaging, on one test the patients drank an instant breakfast drink (eating) and on the other they drank an equivalent volume of water as a control (H 2 O). Thallium-201 imaging was performed immediately postexercise, immediately after eating/H 2 O and 210 min after eating/H 2 O. Between initial and immediate post eating/H 2 O images 201Tl reversible defects occurred in 27/38 regions in the H 2 O test versus 15/38 regions in the eating test (p = 0.02). Over this early time period, plasma 201 Tl activity was significantly higher in the H 2 O test than eating test (p less than 0.05). In conclusion, early reversal of 201 Tl defects may, in part, be the result of higher plasma 201 Tl activity early after initial postexercise 201 Tl imaging

  16. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    International Nuclear Information System (INIS)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli; Zhou Sumin; Hollis, Donna R.; Wong, Terence Z.; Light, Kim L.; Hardenbergh, Patricia H.; Blazing, Michael A.; Marks, Lawrence B.

    2006-01-01

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI ≥25 kg/m 2 compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI ≥25 kg/m 2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT

  17. A Baseline-Free Defect Imaging Technique in Plates Using Time Reversal of Lamb Waves

    International Nuclear Information System (INIS)

    Jeong, Hyunjo; Cho, Sungjong; Wei, Wei

    2011-01-01

    We present an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A 0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional sidebands that contain the time-of-flight information on the defect location. One of the side-band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free imaging of a defect. (fundamental areas of phenomenology(including applications))

  18. Withholding or Continuing Beta-Blocker Treatment Before Dipyridamole Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease? a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Babak Fallahi

    2013-01-01

    Full Text Available Although it has been shown that acute beta-blocker administration may reduce the presence or severity of myocardial perfusion defects with dipyridamole stress, little information is available about the potential effect of chronic beta-blocker treatment on the sensitivity of dipyridamole myocardial perfusion imaging (DMPI.Methods As a randomized clinical trial, one hundred twenty patients (103 male and 17 female with angiographically confirmed CAD who were on long-term beta blocker therapy ([greater than or equal to]3 months enrolled in a randomized clinical trial study. The patients were allocated into two groups: Group A (n=60 in whom the beta-blocker agent was discontinued for 72h before DMPI and Group B (n=60 without discontinuation of beta-blockers prior to DMPI.ResultsNo significant difference was noted between the groups concerning age, sex, type of the injected radiotracer and number of involved coronary vessels. The mean rank of total perfusion scores for whole myocardium (irrespective of reversibility or irreversibility in group B was not significantly different from that of group A, (65.75 vs. 55.25, P=0.096. Regarding the only irreversible perfusion defects, the mean rank of perfusion score in group B was higher than that of group A for whole myocardium (72 vs. 49, P=0.0001; however, no difference was noted between two groups for only reversible perfusion defects (61.0 vs. 60.0, P=0.898. The overall sensitivity of DMPI for the diagnosis of CAD in group A (91.7% was not statistically different from group B (90%.ConclusionBeta-blocker withholding before DMPI did not generally affect the sensitivity of the test for the diagnostic purposes in our study. Thus, beta-blocker withdrawal for just the purpose of diagnostic imaging is not mandatory particularly when medication discontinuation may cause the patients to face increased risk of heart events.

  19. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J T; Kim, C K; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1973-09-15

    Pulmonary perfusion scan with radioactive {sup 113m}In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  20. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    International Nuclear Information System (INIS)

    Lee, J. T.; Kim, C. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Pulmonary perfusion scan with radioactive 113m In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  1. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  2. Diffusion- and perfusion-weighted MRI in a patient with a prolonged reversible ischaemic neurological deficit

    International Nuclear Information System (INIS)

    Neumann-Haefelin, T.; Wittsack, H.J.; Wenserski, F.; Li, T.Q.; Moseley, M.E.; Siebler, M.; Freund, H.J.

    2000-01-01

    We report acute and follow-up diffusion- and perfusion-weighted MRI (DWI, PWI) findings in a patient with a prolonged reversible ischaemic neurological deficit. PWI 12 h after the patient was last seen to be without symptoms revealed a large perfusion deficit in the left posterior MCA territory with a relatively inconspicuous and much smaller abnormality on DWI. Follow-up showed resolution of abnormalities on both DWI and PWI, and conventional MRI was normal, apart from a very slight abnormality, visible only on FLAIR images, at the centre of the initially DWI-positive region. These findings demonstrate the utility of PWI when be used in combination with DWI to investigate the pathophysiology of transient ischemic syndromes. (orig.)

  3. Thallium-201 myocardial scintigraphy and left ventricular function at rest in patients with rest angina pectoris

    International Nuclear Information System (INIS)

    Hakki, A.H.; Iskandrian, A.S.; Kane, S.A.; Amenta, A.

    1984-01-01

    The purpose of this study was to examine the rest thallium-201 perfusion pattern during angina-free periods in 40 patients with rest angina pectoris secondary to coronary artery disease (greater than or equal to 70% diameter narrowing). Seventeen patients had previous Q wave myocardial infarction. The perfusion defects were considered fixed or reversible, depending on the absence or presence of redistribution in the 4-hour delayed images. There were 40 perfusion defects (26 fixed and 14 reversible) in 27 patients whereas 13 patients had normal scans. Reversible perfusion defects were present in 10 patients (25%). Of the 26 fixed perfusion defects, 17 did not have corresponding Q waves. Occluded vessels (63%) had more perfusion defects than vessels with subtotal occlusion (30%) (p less than 0.01). The perfusion defect size was larger in patients with lower ejection fraction than in patients with higher ejection fraction. We conclude: (1) perfusion defects are common in patients with rest angina and are reversible in 25% of patients indicating reduced regional coronary blood flow; (2) the degree of stenosis affects the presence of perfusion defect; (3) fixed defects may be present without corresponding Q waves; and (4) global left ventricular function is related to the size of perfusion defects

  4. Covering the Dorsal Finger Defect with Reverse Cross Finger Flap

    Directory of Open Access Journals (Sweden)

    Kaan Gurbuz

    2014-12-01

    Full Text Available Reconstruction of finger extensor zone defects with or without tendon gaps still remains a challenge for surgeons. Although surgical treatments may differ, and range from the use of local, regional, to free flaps, the outcomes for all cases are not satisfactory. In this case report, we present a case of a 3rd finger extensor side crush injury including a defect of Dd (Digit Dorsal 1, Dd2 and Dd3 defects of extensor zones with tendon gap. Tendon gap was reconstructed using m. palmaris longus tendon graft and the defect was covered with reversed cross-finger flap (random pattern with good cosmetic and excellent functional results.

  5. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  6. Reduced myocardial perfusion reserve in myocardium having coronary artery aneurysm of Kawasaki disease

    International Nuclear Information System (INIS)

    Yoon, S. N.; Lee, D. S.; Choi, J. Y.; Kil, H. R.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Kawasaki disease is a systemic vasculitis involving the coronary arteries at early childhood and cause coronary artery aneurysms and thrombotic occlusions. These coronary artery aneurysms were usually transformed later into stenotic or obstructive lesions, however, the majority of these aneurysms, even the giant ones, are known to be associated with normal epicardial coronary flow. Flow reserve is difficult to assess in aneurysmal arteries with echo or angiography. We performed this study to question if there are abnormalities in flow reserve in myocardial tissue with normal epicardial arterial flow on angiography in patients with Kawasaki disease, dipyridamole stress and rest Tc-99m-sestamibi SPECT were performed in 37 patients (28 boys, 9 girls, mean age 6.6 years). We compared SPECT findings with coronary angiography (CAG) findings in 21 patients who did both studies after finding abnormality on echocardiaography. On CAG, aneurysms were found in 26 arteries of 16 patients, i.e., 10 left main arteries, 6 left anterior descending arteries (LAD), 2 left circumflex arteries (LCX), and 8 right coronary arteries (RCA). Localized and segmental stenotic lesions were found in 11 arteries in 9 patients (LAD: 4, LCX: 1, RCA: 6). Eight of the 10 patients with aneurysms had no obvious stenosis. On stress-rest SPECT, 16(43%) out of 37 patients showed normal perfusion and the other 21(57%) showed reversible or persistent decrease. Among 11 stenotic artery territories, 3(27%) showed persistent and/or reversible perfusion defects. The other 8 were normal. Among 26 aneurysmal artery territories, 12 artery territories showe perfusion decrease. Three of the 5 patients with normal CAG showed persistent and/or transient perfusion defects. Among 14 artery territories with perfusion decrease in the 16 patients, 3(21%) could be localized to vascular territory having stenosis of supplying coronary arteries, 12(86%) were related to the coronary artery aneurysms. Two were not related to

  7. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  8. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism

  9. Reversible ventilation and perfusion abnormalities in unilateral obstructed lung

    International Nuclear Information System (INIS)

    Ward, H.E.; Jones, R.L.; King, E.G.; Sproule, B.J.; Fortune, R.L.

    1982-01-01

    An intraluminal carcinoid tumor obstructing the left mainstem bronchus produced hypoxemia through alteration in ventilation/perfusion matching. Studies of regional lung function using 133-xenon (/sup 133/Xe) and a multiprobe computerized instrumentation system documented a reduction of perfusion to 22 percent and ventilation to 6 percent of the total. There was negligible washout of intravenously injected /sup 133/Xe from the left lung consistent with air trapping. Four days after left mainstem bronchial sleeve resection, perfusion, ventilation and washout of injected xenon had significantly improved and by four months postresection, all measurements were virtually normal, although complete restoration of perfusion in relation to ventilation was delayed. Regional lung function studied with a multiprobe system in this patient provided a clinical model for the study of ventilation and perfusion inter-relationships in large airway obstruction and demonstrated that a prolonged time may be required for return of perfusion to normal

  10. Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients

    DEFF Research Database (Denmark)

    Minarik, David; Senneby, Martin; Wollmer, Per

    2015-01-01

    Background The interpretation of myocardial perfusion scintigraphy (MPS) largely relies on visual assessment by the physician of the localization and extent of a perfusion defect. The aim of this study was to introduce the concept of the perfusion vector as a new objective quantitative method...

  11. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    Science.gov (United States)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  12. Time-course of myocardial perfusion and fatty acid metabolism after coronary reperfusion

    International Nuclear Information System (INIS)

    Sochor, H.; Pachinger, O.; Ogris, E.; Probst, P.; Kaindl, F.

    1985-01-01

    To investigate the relationship and time-course of myocardial perfusion and behaviour of fatty acid uptake and clearance following reperfusion, the authors studied 19 patients after successful intracoronary thrombolysis with Tl-201 and I-123 hepta-decanoic acid (HDA) and planar imaging. Pts were studied acute (A: 48 hours), early (E:6-8 days) and late (L:6-12 months). %-defect size and relative tracer uptake were determined for both markers as well as t1/2 of the early clearance phase for HDA. Late Tl was done as stress test study after dipyridamole infusion. As in a previous report acute HDA uptake-defects were larger than Tl (38 +- 10% vs 24 +- 9%, p<0.05) suggesting a larger area of metabolic impairment than outlined by perfusion. HDA and Tl uptake at A correlated significantly (p<0.01, r=0.86) but HDA uptake was 19% lower than Tl and not different at E and L. Tl stress studies exhibited in 74% reversible ischemia in the area of ''metabolic recovery''. The authors conclude that early after reperfusion uptake of HDA is frequently impaired despite improved perfusion suggesting metabolic derangement showing a slow recovery over time. A multiple tracer approach including metabolic markers may improve the characterization of reperfused myocardium

  13. The prognostic value of 99MTc-MIBI stress-rest myocardial perfusion imaging in patients suspected with coronary artery disease

    International Nuclear Information System (INIS)

    Wu Zhifang; Li Sijin; Liu Jianzhong; Zhang Wanchun

    2004-01-01

    Objective: To evaluate the prognostic value of 99mTc-MIBI stress-rest myocardial perfusion imaging (MPI) for patients suspected with coronary artery disease (CAD). Methods: 206 consecutive patients suspected with CAD (165 males, 41 females; age range 16-90 years, mean age 55.94±12.46 years) underwent 99mTc-MIBI stress-rest myocardial perfusion imaging (two days protocol), 57 pts with hypertension, 68 pts with hyperlipemia, 39 pts with diabetes and 62 pts with the family history of CAD. According to the imaging results, the 206 patients were divided into 3 groups. G1, normal, 135 pts; G2, reversible defects, 20 pts; G3, fixed defects, 51 pts. The mean time of follow-up was 33.25±14.95 (1-56) months. Results: The rate of cardiac events (CE) occurrence of the three groups was 1.5% (2/135), 65% ( 13/20) and 7.8% (4/51) respectively and there was significant difference between them. Kaplan-Meier survival curves analyzing the no-CE rates in the three groups, ischemic patients demonstrated a more significantly lower than normal and infarction ones in the no-CE rates(Log-rank statistic, chi-square 124.89, P <0.0001). The better predictor of future cardiac events is the reversible defect. Over all, 23.9% of the patients with abnormal stress MPI occurred cardiac events, but only 7.5% of the patients with abnormal rest ones did(chi-square 5.80, P =0.016). The prognoses of patients with normal stress MPI result were better than those with normal rest ones (1.5% versus 9.7%, chi-square 8.94, P =0.0028). Compared with rest MPI, the stress one is a better predictable method to analyze the patient' s condition and evaluate the prognosis. Conclusions: 99mTc-MIBI stress-rest myocardial perfusion imaging is a better Methods to evaluate the prognosis of patients suspected with CAD, and the rate of CE occurrence was 65% in reversible defects patients in this study. (authors)

  14. Use of myocardial perfusion imaging to predict the effectiveness of coronary revascularisation in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Johansen, Allan; Hoeilund-Carlsen, Poul Flemming; Moeldrup, Mette; Christensen, Henrik Wulff; Vach, Werner; Haghfelt, Torben

    2005-01-01

    Coronary revascularisation is the treatment of choice in patients with stable angina who have significant stenoses. From a pathophysiological point of view, however, mitigation of angina is to be expected only in the presence of reversible ischaemia. Therefore it was the aim of this study to examine the effect of revascularisation on stable angina in relation to the myocardial perfusion imaging (MPI) pattern prior to intervention. Three hundred and eighty-four patients (58.0±8.8 years) referred for angiography underwent MPI. Prior to MPI and at 2-year follow-up, patients were classified as having typical angina, atypical angina, non-cardiac chest pain or no pain, and the severity of chest pain was graded according to the Canadian Cardiovascular Society (CCS) criteria. The patients themselves estimated their pain on a visual analogue scale. Management was based on symptoms and angiographic findings, since the results of MPI were not communicated. Among the 240 patients who were not revascularised, 79% had typical or atypical angina at study entrance versus 40% at follow-up. In comparison, 93% of the 144 revascularised patients had typical or atypical angina before intervention versus only 36% at follow-up. This additional advantage of invasive therapy was present only in patients with reversible defects; revascularisation had no additional effect in patients with normal perfusion or irreversible defects. Similarly, additional, significant reductions in CCS class and visual analogue score were observed exclusively in patients with reversible defects. In patients referred for coronary angiography owing to known or suspected stable angina, revascularisation was significantly more effective than medical treatment exclusively in patients with reversible ischaemia. (orig.)

  15. Vulval defect after pelvic trauma and its repair with reverse TRAM flap

    African Journals Online (AJOL)

    Introduction: In trauma, a vulval defect may result from avulsion injury or develops after a wound infection with or without necrosis in the event of infected heamatoma formation. Patient: We present a case report of a patient who had a vulval defect following pelvic trauma and its subsequent successful repair with a reversed ...

  16. Ventilation perfusion radionuclide imaging in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Bourke, S.J.; Hawkins, T.; Keavey, P.M.; Gascoigne, A.D.; Corris, P.A.

    1993-01-01

    There is increasing interest in ventilation perfusion (V/Q) imaging in cryptogenic fibrosing alveolitis because of the data these scans provide on the dynamic V/Q relationships in such patients undergoing single lung transplantation. We analysed the V/Q scans of 45 consecutive patients with advanced cryptogenic fibrosing alveolitis being considered for single lung transplantation. Scans were classified according to the presence, severity and degree of matching of defects in ventilation and perfusion images and the results were compared with the data obtained from lung function tests. Ventilation images showed defects in 13 (29%) and ''washout delay'' in 15 (33%) patients; 10 (22%) patients had asymmetric distribution of ventilation with one lung receiving >60% of total ventilation. Perfusion images showed normal perfusion in 8 (18%), mild defects in 18 (40%) and major defects in 19 (42%) patients. The distribution of perfusion between lungs was significantly asymmetric in 20 (45%) patients. V/Q images were matched in 15 (33%), mildly mismatched in 15 (33%) and severely mismatched in 15 (33%) patients, but the degree of V/Q mismatch did not show a relationship to KCO, PaO 2 or A-aO 2 gradient. The appearances were atypical of pulmonary embolism in eight patients. (Author)

  17. Localization of coronary artery disease with exercise electrocardiography: correlation with thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.F.; Freedman, B.; Bailey, I.K.; Uren, R.F.; Kelly, D.T.

    1981-01-01

    In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery

  18. Myocardial perfusion after prolonged submaximal exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Flotats, A.; Mena, E.; Camacho, V.; Tembl, A.; Hernandez, M.A.; Estorch, M.; Carrio, I.; Serra-Grima, R.

    2002-01-01

    Aim: Exercise training in patients with coronary artery disease (CAD) has established benefits. We assessed myocardial perfusion after submaximal but prolonged exercise in patients with CAD, who were enrolled in supervised exercise rehabilitation programs. Material and Methods: Nine patients with CAD enrolled in supervised exercise rehabilitation programs (7 men, 2 women; mean age 54±9 years), 7 with prior AMI and 2 with re-vascularized (CABG) multiple vessel disease, were encouraged to walk/run actively around the perimeter of our Hospital during the annual social sporting event organised in our Institution. Patients were studied by means of perfusion Tc-99m tetrofosmin SPECT imaging after prolonged exercise and at rest (gated SPECT), for two consecutive years. All patients remained symptom free during this interval period. Quantitative analysis was performed dividing polar map images in 13 segments. Tracer activity 9% in the resting image. The analysis was focused on those segments showing perfusion defects. Results: No symptoms other than fatigue were registered during prolonged exercise (range 1-2 hr). There were no significant differences in distance covered (7,462±3,031 m vs. 8,456±2,998 m), heart rate (92±11 bpm vs. 85±13 bpm) and rate-pressure product at the end of exercise (10,804±2,467 vs. 10,403±2,955) or gated SPECT calculated LVEF (44%±19 vs. 46%±20) between the two consecutive annual sporting events. Tracer activity in segments with perfusion defects did not significantly differ between both events. Overall agreement between both examinations regarding patient classification as having scar/ischemia was 77% (kappa=0.49). There was one patient who showed partial reversibility in three segments, consistent with mild anteroapical ischemia, only in the first examination. On the other hand, another patient showed reversibility in one segment (medium septum), only in the second examination, when he covered a distance 1.3 times superior. Conclusions

  19. Tl-201 myocardial perfusion scanning in patients with right bundle branch block coronary artery disease

    International Nuclear Information System (INIS)

    Shirani, J.; Malpani, A.R.; Blend, M.J.; Bekerman, C.

    1990-01-01

    This paper evaluates the specificity of stress T1-201 myocardial perfusion studies (T1-201 MPS) for coronary artery disease (CAD) in patients with right bundle branch block (RBBB). Twenty-four patients with RBBB and atypical chest pain with ECG findings limited to RBBB, adequate stress test (ie, >85% of maximal heart rate for age), and no clinical, hemodynamic, or ECG evidence of ischemia during exercise underwent T1-201 MPS. These perfusion patterns were compared with an equal number of age- and gender-matched controls with a normal ECG who met all other criteria mentioned above. Patients with RBBB showed a significantly higher frequency of reversible inferoposterior T1-201 defects (62.5% vs 20.8%)

  20. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  1. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    International Nuclear Information System (INIS)

    Bryant, Mark; Kauczor, Hans-Ulrich; Ley, Sebastian; Eberhardt, Ralf; Herth, Felix; Menezes, Ravi; Sedlaczek, Oliver; Ley-Zaporozhan, Julia

    2015-01-01

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  2. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Mark; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley, Sebastian [Chirurgische Klinik Dr. Rinecker, Department of Diagnostic and Interventional Radiology, Munich (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); Eberhardt, Ralf; Herth, Felix [Thoraxklinik University of Heidelberg, Department of Pneumology and Critical Care Medicine, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Menezes, Ravi [University of Toronto, Medical Imaging, Toronto (Canada); Sedlaczek, Oliver [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley-Zaporozhan, Julia [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany)

    2015-01-15

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  3. [Acute stent thrombosis and reverse transient left ventricular dilatation after performing a single-photon emission computed tomography myocardial perfusion].

    Science.gov (United States)

    Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J

    2015-01-01

    A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  4. Three-dimensional surface display with [sup 123]I-IMP brain perfusion imaging in patients with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Tomino, Yoshio; Tachibana, Hisao; Sugita, Minoru [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    1994-04-01

    We reconstructed three-dimensional (3D) surface images from SPECT data with N-isopropyl-p [[sup 123]I]-iodo-amphetamine ([sup 123]I-IMP) in 27 patients with Parkinson's disease (group 1), 16 patients with Alzheimer's disease (group 2), 9 patients with Binswanger's disease (group 3), and 11 elderly normal subjects (control group). Three-D reconstruction was performed using distance-shaded method at the threshold levels at intervals of 5% from 45% to 80%. In the control group, no perfusion defects were found in any region at threshold values below 60%, although the frontal and temporal cortices occasionally showed perfusion defects at threshold levels from 60% to 80%. In the group 1 of patients with dementia, perfusion defects were diffuse, particularly in the parietal and temporal cortices even at a threshold of 45%. The group 2 also showed diffuse perfusion defects, particularly in parietal and temporal cortices even at threshold levels as low as 45%. The primary visual cortex was less affected in this group. The demented patients in the group 1 demonstrated perfusion defects similar to those of patients in the group 2, although perfusion defects were more prominent in the group 2. In the group 3, patchy perfusion defects were found most frequently in the frontal region. Perfusion defects in the cerebellum and sensory motor cortex were more frequent in the group 3 than the other two groups, as well as the control group. The demented patients in the group 1 showed perfusion defects in the temporal and parietal cortices and demonstrated a perfusion pattern similar to those in the group 2. The patterns of brain perfusion in the group 3 were obviously different from those in the other two groups. In conclusion, 3D surface display of brain perfusion imaging may be useful for evaluating the cortical hypoperfusion regions in patients with dementia. It may also be of value in the differential diagnosis of cognitive disorders. (J.P.N.).

  5. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  6. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  7. Value of chest X-ray combined with perfusion scan versus ventilation/perfusion scan in acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Turkstra, F.; van Marwijk Kooy, M.; Oostdijk, A. H.; van Beek, E. J.; Büller, H. R.

    2000-01-01

    The main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this

  8. The natural history of takotsubo syndrome: a two-year follow-up study with myocardial sympathetic and perfusion G-SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sestini, Stelvio; Mazzeo, Christian; Castagnoli, Antonio [Nuclear Medicine Unit, N.O.P. - S. Stefano, U.S.L. Toscana Centro, Deptartment of Diagnostic Imaging, Prato (Italy); Pestelli, Francesco; Leoncini, Mario; Bellandi, Francesco [Cardiovascular Unit, N.O.P. - S. Stefano, U.S.L, Toscana Centro, Deptartment of Internal Medicine, Prato (Italy); Mansi, Luigi [Nuclear Medicine Unit, University II Naples, Deptartment of Diagnostic Imaging, Naples (Italy); Carrio, Ignasi [Hospital Sant Pau, Nuclear Medicine, Barcelona (Spain)

    2017-02-15

    To investigate changes in sympathetic activity, perfusion, and left ventricular (LV) functionality in takotsubo cardiomyopathy (TTC) patients from onset (T{sub 0}) to post-onset conditions at 1 month (T{sub 1}), 1-2 years (T{sub 2}, T{sub 3}). Twenty-two patients (70 ± 11 years) underwent serial gated single photon emission tomography (G-SPECT) studies with {sup 123}I-mIBG and {sup 99m}Tc-Sestamibi. Statistics were performed using ANOVA/Sheffe post-hoc, correlation test, and receiver operating characteristic (ROC) curve analysis (p < 0.05). Patients presented at T{sub 0} with LV ballooning and reduced early-late mIBG uptake (95%, 100%), left ventricular ejection fraction (LVEF){sub G-SPECT} (86%) and perfusion (77 %). Adrenergic dysfunction was greater in apex, it overlaps with contractile impairment, and both were more severe than perfusion defect. During follow-up, LVEF{sub G-SPECT}, contractility, and perfusion were normal, while 82% and 90% of patients at T{sub 1} and 50% at T{sub 2} and T{sub 3} continued to show a reduced apical early-late mIBG distribution. These patients presented at T{sub 0}-T{sub 1} with greater impairment of adrenergic function, contractility, and perfusion. A relationship was present within innervation and both perfusion and contractile parameters at T{sub 0} and T{sub 1}, and between the extent of adrenergic defect at T{sub 3} and both the defect extent and age at T{sub 0} (cut-off point 42.5%, 72 years). Outcome for TTC is not limited to a reversible contractile and perfusion abnormalities, but it includes residual adrenergic dysfunction, depending on the level of adrenergic impairment and age of patients at onset. The number of patients, as well as degree of perfusion abnormalities were found to be higher than those previously reported possibly depending on the time-interval between hospital admission and perfusion scan. (orig.)

  9. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  10. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  11. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  12. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  13. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography

    International Nuclear Information System (INIS)

    Nekolla, S.G.; Miethaner, C.; Nguyen, N.; Ziegler, S.I.; Schwaiger, M.

    1998-01-01

    The purpose of this study was to determine the reliability of new software developed for the analysis of cardiac tomographic data. The algorithm delineates the long axis and defines the basal plane and subsequently generates polar maps to quantitatively and reproducibly assess the size and severity of perfusion defects. The developed technique requires an initial manual estimate of the left ventricular long axis and calculates the volumetric maximum myocardial activity distribution. This surface is used to map three-dimensional tracer accumulation onto a two-dimensional representation (polar map), which is the basis for further processing. The spatial information is used to compute geometrical and mechanical properties of a solid model of the left ventricle including the left heart chamber. A new estimate of the axis is determined from this model, and the previously outlined procedure is repeated together with an automated definition of the valve plane until differences between the polar maps can be neglected. This quantitative analysis software was validated in phantom studies with defects of known masses and in ten data sets from normals and patients with coronary artery disease of various severity. We investigated the reproducibility of the maps with the introduction of a similarity criterion where the ratio of two corresponding polar map elements lies within a 10% interval. The maps were also used to measure intra-and interobserver variability in respect of defect size and severity. In the phantom studies, it was possible to reliably assess mass information over a wide range of defects from 5 to 60 g (slope: 1.02, offset -0.68, r = 0.972). Patient studies revealed a statistically significant increase in the reproducibility of the automatic technique compared with the manual approach: 54%±19% (manual) compared with 88%±9% (automatic) for observer 1 and 61%±20% vs 82%±5% for observer 2, respectively. The intervariability analysis showed a significant

  14. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  15. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  16. Increased Regional Epicardial Fat Volume Associated with Reversible Myocardial Ischemia in Patients with Suspected Coronary Artery Disease

    Science.gov (United States)

    Khawaja, Tuba; Greer, Christine; Thadani, Samir R.; Kato, Tomoko S.; Bhatia, Ketan; Shimbo, Daichi; Konkak, Andrew; Bokhari, Sabahat; Einstein, Andrew J.; Schulze, P. Christian

    2015-01-01

    Epicardial adipose tissue is a source of pro-inflammatory cytokines and has been linked to the development of coronary artery disease. No study has systematically assessed the relationship between local epicardial fat volume (EFV) and myocardial perfusion defects. We analyzed EFV in patients undergoing SPECT myocardial perfusion imaging combined with computed tomography (CT) for attenuation correction. Low-dose CT without contrast was performed in 396 consecutive patients undergoing SPECT imaging for evaluation of coronary artery disease. Regional thickness, cross-sectional areas, and total EFV were assessed. 295 patients had normal myocardial perfusion scans and 101 had abnormal perfusion scans. Mean EFVs in normal, ischemic, and infarcted hearts were 99.8 ± 82.3 cm3, 156.4 ± 121.9 cm3, and 96.3 ± 102.1 cm3, respectively (P < 0.001). Reversible perfusion defects were associated with increased local EFV compared to normal perfusion in the distribution of the right (69.2 ± 51.5 vs 46.6 ± 32.0 cm3; P = 0.03) and left anterior descending coronary artery (87.1 ± 76.4 vs 46.7 ± 40.6 cm3; P = 0.005). Our results demonstrate increased regional epicardial fat in patients with active myocardial ischemia compared to patients with myocardial scar or normal perfusion on nuclear perfusion scans. Our results suggest a potential role for cardiac CT to improve risk stratification in patients with suspected coronary artery disease. PMID:25339129

  17. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  18. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  19. Myocardial perfusion assessment at rest and after dipyridamole: MR signal intensity characteristics of reversible and persistent hypoperfusion

    International Nuclear Information System (INIS)

    Wintersperger, B.J.; Penzkofer, H.V.; Huber, A.; Meininger, M.; Scheidler, J.; Reiser, M.; Knez, A.; Haberl, R.; Kerner, M.; Knesewitsch, P.

    2000-01-01

    Methods: Sixteen patients with CAD underwent MR myocardial perfusion assessment at rest and after dipyridamole-induced hyperemia. Qualitative parameters (SI increase, SI upslope) of the SI time-curves were evaluated and characteristics of normal, reversible and persistent hypoperfused myocardium as assessed by 99m TC-SestaMIBI SPECT were compared. Results: Compared with the rest values, normal myocardium showed a significant increase of the SI upslope during hyperemia (P [de

  20. Enhanced magnetic resonance pulmonary perfusion imaging in diagnosing pulmonary embolism: preliminary investigation

    International Nuclear Information System (INIS)

    Huang Xiaoyong; Du Jing; Zhang Zhaoqi; Guo Xi; Yan Zixu; Jiang Hong; Wang Wei

    2005-01-01

    Objective: This study was designed to investigate the sensitivity and specificity of magnetic resonance pulmonary perfusion imaging (MRPP) in diagnosing pulmonary embolism (PE) compared with enhanced magnetic resonance pulmonary angiography (MRPA) and pulmonary radionuclide perfusion imaging. Methods: Fourteen patients were definitely diagnosed as PE, whose ages were from 19 to 71 years old and mean 45.5 ± 19.8 years old. All patients under went MRPA and MRPP and 3 patients were examined again after thrombolytic treatment. Five patients underwent pulmonary radionuclide perfusion imaging. Setting ROI in top, middle, bottom of lung area and abnormal area respectively, we detected signal intensity and time-signal curve to obtain the transformation rate of signal (TROS) during perfusion peak value. Results: In 14 pulmonary embolism patients, MRPA found 62 branches of pulmonary artery obstruction. Fifty-five abnormal pulmonary perfusion zones were found by MRPP, and the above results were very alike. The coincidence was 88.71%. In 14 cases, MRPP could show 25 subsegments lesion below segments. In 5 patients who had both results Of MRPP and ECT at the same time. MRPP shows 33 perfusion defect zones and 37 segments were found by ECT, the sensitivity was 89.19%. After thrombolytic treatment, both the status of the affected pulmonary artery improved markedly and perfusion defect zones reduced obviously in 3 cases by MRPP and MRPA. TROS in normal perfusion zones perfusion defect zones and low perfusion zones had significant difference (t=22.882, P<0.01). Conclusion: Contrast enhanced MR pulmonary perfusion can show both perfusion defect zones and low perfusion zones in pulmonary embolism. Time-signal curve can show the period of maximum no perfusion zones in pulmonary artery embolism zones. And the amplitude of fluctuation is small with miminum TROS. MRPP has significant values especially in showing pulmonary artery embolism in segments and subsegments. Using both MRPP and

  1. Clinical significance of 201Tl reverse redistribution in patients with aorto-coronary bypass surgery

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Tashiisa; Hayashida, Kohei; Kozuka, Takahira

    1987-01-01

    Detection of myocardial ischemia by the stress thallium scan has traditionally been performed using transient defect analysis on exercise, followed by redistribution studies. Worsening of the 201 Tl myocardial image from exercise to redistribution is referred to as reverse redistribution. In this study, we found reverse redistribution in 10 (21%) of 48 angina pectoris patients who had undergone aortocoronary bypass surgery. The clinical significance of this phenomenon in these patients was investigated in relation to angiographic and surgical findings. Reverse redistribution was found to occur in regions which were supplied by bypass grafts. These areas showed increased coronary blood flow and rapid thallium washout. Our results indicate that a perfusion defect in the bypass region of the redistribution image might be caused by relatively rapid washout in the bypass graft region compared to the adjacent normal myocardium. These results should be considered in the clinical interpretation of stress thallium scans. (orig.)

  2. Assessment of the effect of revascularization early after CABG using ECG-gated perfusion single-photon emission tomography

    International Nuclear Information System (INIS)

    Kubo, Shigeto; Tadamura, Eiji; Kudoh, Takashi; Inubushi, Masayuki; Konishi, Junji; Ikeda, Tadashi; Koshiji, Takaaki; Nishimura, Kazunobu; Komeda, Masashi; Tamaki, Nagara

    2001-01-01

    When an arterial graft is used, reversible perfusion defects on single-photon emission tomography (SPET) perfusion images are occasionally observed early after coronary artery bypass graft surgery (CABG), owing to the restricted flow capacity. The purpose of this study was to determine whether the functional information obtained with electrocardiography (ECG)-gated perfusion SPET could be helpful in evaluating the effect of revascularization early after CABG. Twenty-three patients (18 men and 5 women, mean age 65±9 years) underwent stress/re-injection thallium-201 ECG-gated SPET before and 4 weeks after CABG (13 with exercise and 10 with dipyridamole). Patency of all grafts was confirmed by coronary angiography 1 month after CABG. Cardiac functional data including the left ventricular ejection fraction (LVEF) and the transient ischaemic dilatation (TID) ratio were analysed using a commercially available automated program. The conventional stress and re-injection tomograms were interpreted by means of a five-point scoring system in a nine-segment model. Stress-induced reversible 201 Tl perfusion defects were present in 64% of the myocardial segments bypassed by patent arterial grafts, in contrast to 42% of the myocardial segments bypassed by patent venous grafts (χ 2 =7.8, P=0.005). Of the 23 patients, 12 showed improvement in summed ischaemic scores (group 1), while 11 had no change or deterioration (group 2), although all grafts were patent on postoperative catheterization. The TID ratio improved in both group 1 and group 2 before and after CABG (1.14±0.13 vs 0.99±0.07, P=0.001 and 1.09±0.07 vs 0.94±0.05, P=0.002, respectively). However, LVEF did not significantly improve in group 1 or group 2 after CABG (42.5%±9.9% vs 47.5%±11.8%, and 52.1%±7.5% vs 53.1%±5.9%, respectively). Perfusion imaging or LVEF assessment is of limited value early after CABG. The TID ratio obtained with ECG-gated perfusion SPET may be a useful marker to evaluate the effect of

  3. GAMMAGRAFÍA DE PERFUSIÓN MIOCÁRDICA EN MUJERES POSMENOPÁUSICAS CON ANGINA Y CORONARIAS EPICÁRDICAS ANGIOGRÁFICAMENTE NORMALES / Myocardial perfusion scintigraphy in postmenopausal women with angina and angiographically normal epicardial coronary

    Directory of Open Access Journals (Sweden)

    Sherien Sixto Fernández

    2011-03-01

    Full Text Available Introduction and Objectives: Microvascular angina is common in postmenopausal women. Myocardial ischemia was induced by stress testing, and reports have been published about the relationship between endothelial dysfunction and myocardial perfusion. The objective of this research was to determine whether myocardial ischemia can be evidenced by abnormalities in perfusion and function, as detected by myocardial scintigraphy in women with typical angina, normal coronary angiography and endothelial dysfunction. Methods: 59 women underwent lipid and endothelial function measurements by brachial artery ultrasound, in addition, a 24-hour ECG study (Holter. During the scintigraphy a stress-rest protocol was applied. Patients were divided into two groups according to presence (group I or absence (group II of myocardial perfusion defects. Results: 21 patients showed perfusion defects. 57 % of group I exhibited greater endothelial dysfunction. Only twelve patients showed reversible perfusion defects, and 75 % of the cases was associated with a reduction of post-stress left ventricular ejection fraction, greater than 5 %, and regional abnormalities of wall motion. Three patients in group I showed evidence of ischemia compared with four in Group II. Conclusions: The stress-induced ischemia was associated with a reduced post-stress ejection fraction and endothelial dysfunction in the studied women, and no ischemic changes in the Holter were found.

  4. Regional cortical hyper perfusion on perfusion CT during postical motor deficit: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Hye Jin [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2013-08-15

    Postictal neurologic deficit is a well-known complication mimicking the manifestation of a stroke. We present a case of a patient with clinical evidence of Todd's paralysis correlating with reversible postictal parenchymal changes on perfusion CT and magnetic resonance (MR) imaging. In this case, perfusion CT and MR imaging were helpful in the differential diagnosis of stroke-mimicking conditions.

  5. A comparison of adenosine and arbutamine for myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Anagnostopoulos, C.; Pennell, D.; Francis, J.; Serup-Hansen, K.; Davies, G.; Underwood, R.

    1998-01-01

    We have compared our standard stress protocol (adenosine combined with exercise) with the new stress agent arbutamine, for thallium-201 myocardial perfusion imaging (MPI) in order to assess the comparative value of arbutamine. We studied 23 patients referred for MPI, and each patient had two studies (18 males, median age 66 years, five with previous myocardial infarction). Uptake scores were assigned to each of nine segments, and the extent and severity of defects were measured using a polar plot. Haemodynamic changes were greater with arbutamine (rate-pressure product increase 78% vs 51%, P = 0.003). Symptoms were experienced by 21 patients with arbutamine and 16 with adenosine (P = 0.07). Agreement between the techniques for classification of patients as normal or as having reversible, fixed or mixed defects was good (19 of 23 studies, 83%, κ = 0.76). Agreement for similar classification of segments was also good (82%, κ = 0.71). Segmental agreement for stress scores was good (86%, κ = 0.77). However, mean size of stress defect was larger with adenosine (83±52 pixels vs 65±48 pixels, P<0.05), though severity and reversibility were similar (P = NS). We conclude that arbutamine provides comparable results to those obtained with adenosine and exercise and that the observed differences are not clinically significant. (orig.)

  6. Reverse peroneal artery flap for large defects of ankle and foot: A reliable reconstructive technique

    Directory of Open Access Journals (Sweden)

    Jose Tharayil

    2012-01-01

    Full Text Available Background: Large soft tissue defects around the lower third of the leg, ankle and foot always have been challenging to reconstruct. Reverse sural flaps have been used for this problem with variable success. Free tissue transfer has revolutionised management of these problem wounds in selected cases. Materials and Methods: Twenty-two patients with large defects around the lower third of the leg, ankle and foot underwent reconstruction with reverse peroneal artery flap (RPAF over a period of 7 years. The mean age of these patients was 41.2 years. Results: Of the 22 flaps, 21 showed complete survival without even marginal necrosis. One flap failed, where atherosclerotic occlusion of peroneal artery was evident on the table. Few patients had minor donor site problems that settled with conservative management. Conclusions: RPAF is a very reliable flap for the coverage of large soft tissue defects of the heel, sole and dorsum of foot. This flap adds versatility in planning and execution of this extended reverse sural flap.

  7. Evaluation in dogs of a new double-dose technique for imaging changes in myocardial perfusion

    International Nuclear Information System (INIS)

    Rothendler, J.A.; Okada, R.D.; Strauss, H.W.; Chesler, D.A.; Pohost, G.M.

    1984-01-01

    Assessment of myocardial perfusion with thallium immediately before and after an intervention that alters blood flow has been difficult due to presence of residual activity from the first tracer dose at the time of the second imaging. In a canine model the authors investigated a technique using two separate thallium injections during an intervention and after its reversal. Images were obtained after each injection, and a difference image was obtained by subtracting the first from the second image to correct for tracer persisting from the first injection. Interventions on coronary blood flow included: transient occlusion, subcritical stenosis with dipyridamole infusion, and permanent occlusion. The first images showed defects corresponding to the occlusion or stenosis, while the ''difference'' images correlated with myocardial perfusion at the time of the second injection

  8. Decreased perfusion in myocardial region of normal donor artery secondary to collateral development

    International Nuclear Information System (INIS)

    Koga, Y.; Takahashi, M.; Kojima, A.; Takaki, Y.; Tomiguchi, S.; Hirota, Y.; Kugiyama, K.; Yasue, H.; Hayasaki, K.; Kumamoto Saiseikai Hospital

    1992-01-01

    Thirty-one patients suffering from single vessel exertional angina with collaterals (Group A) were evaluated by stress 201 Tl myocardial emission CT (Tl-SPECT) with 16 controls of severely stenotic single vessel exertional angina without collaterals (Group B). Group A included 21 patients (68%) who showed an extensive perfusion defect in double artery myocardial regions, including the normal donor artery myocardial region (DMR). However, there were no such cases in Group B, giving a significant difference between these 2 groups (p < 0.001). Four patients in Group A, having a perfusion defect both in DMR and in the collateral dependent myocardial region (CMR) underwent a successful percutaneous transluminal coronary angioplasty (PTCA) with disappearance of collaterals. Tl-SPECT findings after PTCA showed no perfusion defect either in CMR or in DMR. This has been explained on the basis that the coronary collaterals stole blood and produced perfusion defect in DMR. (orig.)

  9. Regional glucose utilization in infarcted and remote myocardium: its relation to coronary anatomy and perfusion.

    Science.gov (United States)

    Fragasso, G; Chierchia, S L; Landoni, C; Lucignani, G; Rossetti, E; Sciammarella, M; Vanoli, G E; Fazio, F

    1998-07-01

    We studied the relationship between coronary anatomy, perfusion and metabolism in myocardial segments exhibiting transient and persistent perfusion defects on stress/rest 99Tcm-MIBI single photon emission tomography in 35 patients (31 males, 4 females, mean age 56 +/- 7 years) with a previous myocardial infarction. Quantitative coronary angiography and assessment of myocardial perfusion reserve and glucose metabolism were performed within 1 week of one another. Perfusion was assessed by SPET after the intravenous injection of 740 MBq of 99Tcm-MIBI at rest and after exercise. Regional myocardial glucose metabolism was assessed by position emission tomography at rest (200 MBq of 18F-2-deoxyglucose, FDG) after an overnight fast with no glucose loading. All 35 patients exhibited persistent perfusion defects consistent with the clinically identified infarct site, and 27 (77%) also showed various degrees of within-infarct FDG uptake; 11 patients developed exercise-induced transient perfusion defects within, or in the vicinity of, 15 infarct segments and resting FDG uptake was present in 10 of these segments (67%). Five patients also showed exercise-induced transient perfusion defects in nine segments remote from the site of infarct: resting FDG uptake was present in six of these regions (67%). Finally, nine patients had increased glucose uptake in non-infarcted regions not showing transient perfusion defects upon exercise testing and perfused by coronary arteries with only minor irregularities. Our results confirm the presence of viable tissue in a large proportion of infarct sites. Moreover, FDG uptake can be seen in regions perfused by coronary arteries showing minor irregularities, not necessarily resulting in detectable transient perfusion defects on a MIBI stress scan. Since the clinical significance of such findings is not clear, further studies should be conducted to assess the long-term evolution of perfusion, function and metabolism in non

  10. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X

    International Nuclear Information System (INIS)

    Saghari, Mohsen; Assadi, Majid; Eftekhari, Mohammad; Yaghoubi, Mohammad; Fard-Esfahani, Armaghan; Malekzadeh, Jan-Mohammad; Sichani, Babak Fallhi; Beiki, Davood; Takavar, Abbas

    2006-01-01

    Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed

  11. Computer program for regional assessment of lung perfusion defect. Part II - verification of the algorithm

    International Nuclear Information System (INIS)

    Stefaniak, B.

    2002-01-01

    As described earlier, a dedicated computer program was developed for quantitative evaluation of regional lung perfusion defects, visualized by pulmonary scintigraphy. The correctness of the basic assumptions accepted to construct the algorithms and of the all program functions needed to be checked, before application of the program into the clinical routine. The aim of this study was to verified the program using various software instruments and physical models. Evaluation of the proposed method was performed using software procedures, physical lung phantom, and selected lung image.The reproducibility of lung regions, defined by the program was found excellent. No significant distortion of registered data was observed after ROI transformation into the circle and retransformation into the original shape. The obtained results comprised parametric presentation of activity defects as well as a set of numerical indices which defined extent and intensity of decreased counts density. Among these indices PD2 and DM* were proved the most suitable for the above purposes. The obtained results indicate that the algorithms used for the program construction were correct and suitable for the aim of the study. The above algorithms enable function under study to be presented graphically with true imaging of activity distribution, as well as numerical indices, defining extent and intensity of activity defects to calculated. (author)

  12. Augmentation of limb perfusion and reversal of tissue ischemia produced by ultrasound-mediated microbubble cavitation.

    Science.gov (United States)

    Belcik, J Todd; Mott, Brian H; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J; Ammi, Azzdine; Linden, Joel M; Lindner, Jonathan R

    2015-04-01

    Ultrasound can increase tissue blood flow, in part, through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation and sought to characterize the biological mediators. Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in nonischemic mice after unilateral 10-minute exposure to intermittent ultrasound alone (mechanical index, 0.6 or 1.3) or ultrasound with lipid microbubbles (2×10(8) IV). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (Pultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3- and 10-fold higher than control for mechanical index 0.6 and 1.3, respectively; Pultrasound and microbubbles by 70% (Pultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40%-50% reduction in flow), ultrasound (mechanical index, 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control nonischemic limb. Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of endothelial nitric oxide synthase. © 2015 American Heart Association, Inc.

  13. Role of myocardial perfusion scintigraphy post invasive coronary angiography in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Harisankar, C.N.B.; Mittal, Bhagwant Rai; Kamaleshwaran, K.K.; Bhattacharya, Anish; Singh, Baljinder; Mahajan, Rajiv

    2010-01-01

    The presence of severe hypokinesia or akinesia and near complete stenotic lesions on coronary angiography, in a patient with acute myocardial infarction raises a question of viability in the involved territory and its response to revascularization. The decision of revascularization can be effectively taken after myocardial perfusion scintigraphy (MPS). Aim: To evaluate the role of MPS in patients with acute or recent myocardial infarction after invasive coronary angiography. Materials and Methods: Thirty-five patients (27 Males, 8 Females; Mean age 54 years) with acute myocardial infarction, who underwent invasive angiography, were included prospectively. Invasive angiography was attempted during the episode of acute chest pain in 20 patients. Fifteen patients underwent angiography without MPS because of non-availability of MPS at the time of initial presentation in the referring hospital. Revascularization was deferred because of complete/near complete block of artery with hypokinesia/akinesia of the distal LV segments in 32/35 patients and 50 to 70% block in 3/35. These patients were subjected to MPS. Results: Twenty patients underwent stress MPS and 15 underwent nitrate-augmented rest re-distribution study (RR study). Imaging was performed using the hybrid SPECT/CT system. The average defect size of the perfusion defect was 34% (5 - 57% range). Sixteen patients (46%) had fixed perfusion defects. Reversible ischemia was present in 19 (54%). Ten patients had a 10% of the LV myocardium, and underwent the invasive revascularization procedure. Conclusion: MPS is invaluable in patients who have total/near total occlusion of the coronary artery and distal segment hypokinesia or akinesia on invasive angiography. One in four patients, deemed to have non-viable myocardium, underwent an invasive revascularization after undergoing MPS. (author)

  14. Brain Perfusion Changes in Intracerebral Hemorrhage

    International Nuclear Information System (INIS)

    Mititelu, R.; Mazilu, C.; Ghita, S.; Rimbu, A.; Marinescu, G.; Codorean, I.; Bajenaru, O.

    2006-01-01

    Full text: Purpose: Despite the latest advances in medical treatment and neuro critical care, patients suffering spontaneous intracerebral hemorrhage (SICH) still have a very poor prognosis, with a greater mortality and larger neurological deficits at the survivors than for ischemic stroke. Many authors have shown that there are many mechanisms involved in the pathology of SICH: edema, ischemia, inflammation, apoptosis. All of these factors are affecting brain tissue surrounding hematoma and are responsible of the progressive neurological deterioration; most of these damages are not revealed by anatomical imaging techniques. The aim of our study was to asses the role of brain perfusion SPECT in demonstrating perfusion changes in SICH patients. Method: 17 SICH pts were studied. All pts underwent same day CT and brain SPECT with 99mTcHMPAO, 24h-5d from onset of stroke. Results: 14/17 pts showed a larger perfusion defect than expected after CT. In 2 pts hematoma diameter was comparable on CT and SPECT; 1pt had quasinormal aspect of SPECT study. In pts with larger defects, SPECT revealed a large cold spot with similar size compared with CT, and a surrounding hypo perfused area. 6/17 pts revealed cortical hyper perfusion adjacent to hypo perfused area and corresponding to a normal-appearing brain tissue on CT. In 3 pts we found crossed cerebellar diaskisis.In 2 pts we found cortical hypo perfused area in the contralateral cortex, with normal appearing brain tissue on CT. Conclusions: Brain perfusion SPECT revealed different types of perfusion changes in the brain tissue surrounding hematoma. These areas contain viable brain tissue that may be a target for future ne uroprotective strategies. Further studies are definitely required to demonstrate prognostic significance of these changes, but we can conclude that brain perfusion SPECT can play an important role in SICH, by early demonstrating functional changes responsible of clinical deterioration, thus allowing prompt

  15. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  16. The clinical significance of abnormal 99Tcm-MIBI myocardial perfusion tomography in patients with hypertension

    International Nuclear Information System (INIS)

    Yang Yongzhen; Li Zhaoping; Liu Yimin; Zhang Weifang; Zhang Yanyan; Zhang Songlin; Wang Xin; Mao Yuan

    2000-01-01

    Objective: To evaluate the clinical significance of abnormal myocardial perfusion tomography in the hypertensive patients with normal coronary angiography. Methods: Qualitative diagnosis, the average counts ratio of lateral to septal segments (L/S) and the ratio of stress L/S to rest L/S from stress and rest 99 Tc m -sestamibi myocardial perfusion tomography (MPT), and every clinical characteristic and the results from other examinations were compared between hypertensive patients (HP) and normotensive controls (NC). Every risk factor leading to coronary artery disease and related indexes in patients with positive MPT were compared with the results of patients with negative MPT. Results: 1) The positive rate of MPT in HP was obviously higher than that of NC,which was 61.9% vs 9.1%, respectively. Most focuses of MPT were reversible defects (RD), a few of them accompanied by reverse reversible defects (RRD). There were many more angina pectoris and heart arrhythmia attacks in HP than in NC. 2) The ratio of stress L/S to rest L/S of HP was lower than that of NC (P<0.05). 3) The ratio of stress L/S to rest L/S of the patients with positive MPT in HP significantly decreased compared with that of the patients with negative MPT (P<0.01). There were more patients being addicted to smoking and drinking in those with a positive than in those with a negative MPT (53.8% versus 12.5%, P<0.05). 4) The abnormal defects of MPT in HP were almost seen in any segment of left ventricle and most of the patients had no left ventricular hypertrophy, but did smoke and drink. Conclusions: 1)Abnormal MPT exist in the HP with normal coronary angiography and not necessarily with left ventricular hypertrophy. 2)The long-term addiction of smoking and drinking was one of the risk factors leading to arouse myocardial ischemia in HP

  17. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  18. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  19. Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hedén Bo

    2009-08-01

    Full Text Available Abstract Background It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem. Methods In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR with delayed-enhancement technique to confirm or exclude myocardial infarction. Results There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR. Conclusion Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.

  20. Role of myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Aleem, M.

    2007-01-01

    Full text: In the cardiac emergency department, a number of patients present with acute chest pain. In case of non diagnostic ECG and enzymes, accurately categorizing the patient in high and low probability is difficult. Aim of study was to evaluate the role of resting myocardial perfusion imaging (MPI) in patients with acute coronary syndrome (ACS) and then to compare the results with subsequent stress imaging. Material and Methods. A total of 34 patients were selected for the study, which were divided into three groups on the basis of respective probabilities of having ACS. This probability was decided on the basis of nature of chest pain, ECG findings, enzymes levels, and age and sex. Arbitrary score was given to patient's condition. This score ranged from 1 to 14. Patients with score between 1-6 were assigned low probability, from 7-10 were assigned intermediate probability and patients having score greater than 11 were placed in high probability groups. Patients in the low and intermediate probability groups were injected with Tc 99 m- MIBI within 6 hours of onset of chest pain and were undergone resting myocardial perfusion imaging (MPI) 3 to five hours after injection.. Imaging in high probability group was performed at discharge. Four weeks after the acute event all the patients underwent stress myocardial perfusion imaging. Results: All patients (100%) with low probability of ACS (n=10) showed negative resting scans. On stress MPI two patients (20%) showed new defects. Patient with high probability of ACS (n=12), all were positive 100% on resting MPI. On stress MPI, three showed (25%) no change from rest MPI, while nine patients (75%) showed augmentation of defects and four out of these nine patients (33%) also showed new perfusion defects. Patients with intermediate probability of ACS (n=12), three showed positive rest MPI (25%). On stress MPI out of these three cases, one showed (8%) no change from rest MPI and two showed (17%) augmentation of defect

  1. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  2. Evaluation of renal transplant perfusion by functional imaging

    International Nuclear Information System (INIS)

    Nicoletti, R.

    1990-01-01

    Radionuclide angiography (RNA) is used as a noninvasive method for the evaluation of renal transplant perfusion. The computer processing method generally used, based on regions of interest, is unsatisfactory because it does not permit the regional differentiation of perfusion defects. Furthermore, the subjective delineation of the regions of interest introduces considerable inter-observer variation of results. We developed a processing method which is less operator-dependent and permits the evaluation of local defects; it is based on the concept of functional imaging. The method was evaluated in 62 patient examinations, which were subdivided into four groups: Normal transplant perfusion (23 examinations), acute tubular necrose (ATN) (16), cellular rejection (13), and vascular rejection (10). Quantitative results derived from profile curves were combined with visual estimation of the functional images and yielded a synoptic graph which allowed differentiation into three groups: Normal transplant perfusion (sensitivity 0.78, specificity 0.97), ATN or cellular rejection (sens. 0.83, spec. 0.82), and vascular rejection (sens. 0.90, spec. 0.92). (orig.)

  3. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  4. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  5. THYROID HORMONE REVERSES AGING-INDUCED MYOCARDIAL FATTY ACID OXIDATION DEFECTS AND IMPROVES THE RESPONSE TO ACUTELY INCREASED AFTERLOAD

    Energy Technology Data Exchange (ETDEWEB)

    Ledee, Dolena; Portman, Michael A.; Kajimoto, Masaki; Isern, Nancy G.; Olson, Aaron

    2013-06-07

    Background: Subclinical hypothyroidism occurs during aging in humans and mice and may contribute to development of heart failure. Aging also impairs myocardial fatty acid oxidation, causing increased reliance on flux through pyruvate dehydrogenase (PDH) to maintain function. We hypothesize that the metabolic changes in aged hearts make them less tolerant to acutely increased work and that thyroid hormone reverses these defects. Methods: Studies were performed on young (Young, 4-6 months) and aged (Old, 22-24 months) C57/BL6 mice at standard (50 mmHg) and high afterload (80 mmHg). Another aged group received thyroid hormone for 3 weeks (Old-TH, high afterload only). Function was measured in isolated working hearts along with substrate fractional contributions (Fc) to the citric acid cycle (CAC) using perfusate with 13C labeled lactate, pyruvate, glucose and unlabeled palmitate and insulin. Results: Cardiac function was similar between Young and Old mice at standard afterload. Palmitate Fc was reduced but no individual carbohydrate contributions differed. CAC and individual substrate fluxes decreased in aged. At high afterload, -dP/dT was decreased in Old versus Young. Similar to low afterload, palmitate Fc was decreased in Old. Thyroid hormone reversed aging-induced changes in palmitate Fc and flux while significantly improving cardiac function. Conclusion: The aged heart shows diminished ability to increase cardiac work due to substrate limitations, primarily impaired fatty acid oxidation. The heart accommodates slightly by increasing efficiency through oxidation of carbohydrate substrates. Thyroid hormone supplementation in aged mice significantly improves cardiac function potentially through restoration of fatty acid oxidation.

  6. Three-dimensional surface display of brain perfusion with 123I-IMP in Parkinson's disease

    International Nuclear Information System (INIS)

    Tachibana, H.; Kawabata, K.; Tomino, Y.; Sugita, M.; Fukuchi, M.

    1994-01-01

    We reconstructed three-dimensional (3D) surface images from single-photon emission computed tomography (SPECT) data using N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) in 27 patients with Parkinson's disease and 11 normal control subjects. The 3D reconstruction was performed using distance-shaded methods at threshold levels with an interval of 5% from 45-80%. Any area of decreased perfusion at each threshold level was visualised as a defect area by the algorithm. In nondemented patients with Parkinson's disease, perfusion defects were frequently found in the parietal cortex at a threshold value of 65%. In demented patients, perfusion defects were frequently seen at thresholds of 45-65%, and were more marked in the temporal and parietal cortex bilaterally. This suggests that dementia in Parkinson's disease is related to a reduction of perfusion in the temporoparietal cortex. (orig.)

  7. Reversal of diaschisis by zolpidem

    International Nuclear Information System (INIS)

    Claus, R.P.; Nel, H.W.; Sathekge, M.

    2004-01-01

    Full text: Introduction: Recent literature has reported on clinical improvement after zolpidem, a GABAergic anti insomnia drug, in brain injury and stroke patients. In this study, the effect of zolpidem on crossed cerebellar diaschisis was investigated in such patients. Method: Four patients with crossed cerebellar diaschisis after brain injury or stroke were investigated before and after application of 10 mg zolpidem by 99mTc HMPAO brain SPECT. Result: Apart from clinical improvements, 99mTc HMPAO brain SPECT studies showed reversal of the crossed cerebellar diaschisis and improvement of perfusion defects after zolpidem. Conclusion: 99mTc HMPAO brain SPECT may have a role to pre-select brain injury and stroke patients who will benefit clinically from zolpidem therapy. (author)

  8. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    Science.gov (United States)

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  9. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-01-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy

  10. Myocardial perfusion changes in patients irradiated for left-sided breast cancer and correlation with coronary artery distribution

    International Nuclear Information System (INIS)

    Lind, Pehr A.; Pagnanelli, Robert; Marks, Lawrence B.; Borges-Neto, Salvador; Hu, Caroline; Zhou, S.-M.; Light, Kim; Hardenbergh, Patricia H.

    2003-01-01

    Purpose: To evaluate postradiation regional heart perfusion changes with single photon emission tomography (SPECT) myocardial perfusion imaging in 69 patients treated with tangential photon beams radiation therapy (RT) for left-sided breast cancer. To correlate SPECT changes with percent irradiated left ventricle (LV) volume and risk factors for coronary artery disease (CAD). Methods and Materials: Rest SPECT of the LV was acquired pre-RT and at 6-month intervals post-RT. The extent of defects (%) with a severity > 1.5 standard deviations below the mean was quantitatively analyzed for the distributions of the left anterior descending (LAD) artery, left circumflex (LCX) artery, and right coronary artery (RCA) based on computer assisted polar map reconstruction (i.e., bull's-eye-view). Changes in perfusion were correlated with percent irradiated LV receiving > 25 Gy (range 0-32%). Data on patient- and treatment-related factors were collected prospectively (e.g., cardiac premorbidity, risk factors for CAD, chemotherapy, and hormonal treatment). Results: In the LAD distribution, there were increased perfusion defects at 6 months (median 11%; interquartile range 2-23) compared with baseline (median 5%; interquartile range 1-14) (p<0.001). There were no increases in perfusion defects in the LCX or RCA distributions. In multivariate analysis, the SPECT perfusion changes in the LAD distribution at 6 months were independently associated with percent irradiated LV (p<0.001), hormonal therapy (p=0.005), and pre-RT hypercholesterolemia (p=0.006). The SPECT defects in the LAD distribution at 12 and 18 months were not statistically different from those at 6 months. The perfusion defects in the LAD distribution were limited essentially to the regions of irradiated myocardium. Conclusion: Tangential photon beam RT in patients with left-sided breast cancer was associated with short-term SPECT defects in the vascular distribution corresponding to the radiation portals. Factors

  11. Assessment of myocardial perfusion using a new scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M.N

    1987-01-01

    This work assessed a new compound: Tc-99m tertiary butyl isonitrile (T-BIN) in scanning the normal myocardium in dogs. Experimentally induced myocardial infarcts (M.I.) were detected. The compound cleared significantly from the blood within 15 minutes and from the lungs within an hour after intravenous administration. Liver uptake was high and remained so. Cardiac uptake occurred quickly and continued for 6 hours. Comparable results were obtained in normal humans and patients. Myocardial scanning was best after 60 minutes at rest or 30 minutes after exercise. Liver uptake sometimes obscured the detection of inferior M.I. but this problem was reduced using a 45/sup 0/ left anterior oblique view with a 20/sup 0/ cranial tilt. At rest 9/10 patients with M.I. showed defects corresponding to the infarct sites. In 20 patients with angina pectoris 16 had perfusion defects on exercise. In 15/16 patients reversible ischaemia was demonstrated. The reperfusion scans were best obtained at 4 hours post exercise. Both Tl-201 and T-BIN detected equally the infarcts (3/3) but in patients with angina 8/10 with T-BIN and 6/10 with Tl-201 showed defects. ECG gating of the T-BIN scans was also studied.

  12. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  13. Three-dimensional surface display of brain perfusion with [sup 123]I-IMP in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tachibana, H [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Kawabata, K [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Tomino, Y [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Sugita, M [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Fukuchi, M [Dept. of Nuclear Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan)

    1994-05-01

    We reconstructed three-dimensional (3D) surface images from single-photon emission computed tomography (SPECT) data using N-isopropyl-p[[sup 123]I]-iodoamphetamine ([sup 123]I-IMP) in 27 patients with Parkinson's disease and 11 normal control subjects. The 3D reconstruction was performed using distance-shaded methods at threshold levels with an interval of 5% from 45-80%. Any area of decreased perfusion at each threshold level was visualised as a defect area by the algorithm. In nondemented patients with Parkinson's disease, perfusion defects were frequently found in the parietal cortex at a threshold value of 65%. In demented patients, perfusion defects were frequently seen at thresholds of 45-65%, and were more marked in the temporal and parietal cortex bilaterally. This suggests that dementia in Parkinson's disease is related to a reduction of perfusion in the temporoparietal cortex. (orig.)

  14. Fabrication and perfusion culture of anatomically shaped artificial bone using stereolithography

    International Nuclear Information System (INIS)

    Du, Dajiang; Asaoka, Teruo; Ushida, Takashi; Furukawa, Katsuko S

    2014-01-01

    Because patient bone defects are usually varied and complicated in geometry, it would be preferred to fabricate custom-made artificial bone grafts that are anatomically specific to individual patient defects. Using a rabbit femoral segment as a bone reconstruction model, we successfully produced customized ceramic scaffolds by stereolithography, which not only had an anatomically correct external shape according to computed tomography data but also contained an interconnecting internal network of channels designed for perfusion culture. Rabbit bone marrow stromal cells were isolated and cultured with these scaffolds using a novel oscillatory perfusion system that was stereolithographically fabricated to fit well to the unique scaffold shapes. After five days of three-dimensional culture with oscillatory perfusion, the cells attached and proliferated homogenously in the scaffolds. However, control cells inside the scaffolds cultured under static conditions were dead after prolonged in vitro culture. Cellular DNA content and alkaline phosphatase activities were significantly higher in the perfusion group versus the static group. Therefore, anatomically correct artificial bone can be successfully constructed using stereolithography and oscillatory culture technology, and could be useful for bone engraftment and defect repair. (paper)

  15. Myocardial perfusion in patients with left bundle branch block and without coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1992-01-01

    For the evaluation of myocardial perfusion in patients with left bundle branch block (LBBB), we performed exercise stress (Ex)-redistribution (RD) myocardial tomography with thallium-201 ( 201 Tl) in 23 patients with LBBB and without coronary artery disease (CAD). Myocardial images in patients with LBBB were compared with those of 9 patients with CAD who showed Ex induced transient septal defect. Bull'-eye maps ( 201 Tl distribution maps at Ex and RD and 201 Tl washout rate [WOR] map) were made from myocardial tomograms. In 23 patients with LBBB, 15 patients (65%) developed myocardial perfusion abnormality. In 10 (67%) of these 15 patients, transient perfusion defect appeared in the entire septum (diffuse type). On the other hand in 5 patients (33%), localized fixed perfusion defect developed at the boundary between septum and anterior wall (focal type). In focal type, every patient had other disease such as hypertension, aortic stenosis or sick sinus syndrome. While in patients with diffuse type, other diseases were observed in 30% (p 201 Tl WOR and 201 Tl uptake ratio of septum to lateral wall indicated that exercise induced septal defect was slighter in diffuse type than CAD. These points might be useful to differentiate whether CAD participates in the septal defect or not in patients with LBBB. (author)

  16. MR-based assessment of pulmonary ventilation-perfusion in animal models

    International Nuclear Information System (INIS)

    Yang Jian; Wan Mingxi; Guo Youmin

    2003-01-01

    Objective: To show the feasibility and value in the diagnosis of airway obstruction and pulmonary embolism with MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging. Methods: Eight canines were implemented for peripheral pulmonary embolism by intravenous injection of gelfoam granules at pulmonary segmental arterial level, and five of them were formed airway obstruction models by inserting self-made balloon catheter at second-bronchia. The oxygen-enhanced MR ventilation imaging was introduced by subtracting the images of pre- and post- inhaled pure oxygen. The MR pulmonary perfusion imaging was achieved by the first-pass contrast agent method. Moreover, the manifestation of MR ventilation and perfusion imaging was observed and contradistinguished with that of general pathologic anatomy, ventilation-perfusion scintigraphy, and pulmonary angiography. Results: The manifestations of airway obstruction regions in MR ventilation and perfusion imaging were matched, but those of pulmonary embolism regions were dismatched. The defect range of airway obstruction in MR ventilation image was smaller than that in ventilation scintigraphy. The abnormal perfusion regions of pulmonary embolism were divided into defect regions and reduce regions based on the time courses of signal intensity changes. The sensitivity and specificity of diagnosis on pulmonary embolism by MR ventilation combined with perfusion technique were 75.0% and 98.1%. The diagnostic results were in good coherence with ventilation-perfusion scintigraphy and pulmonary angiography (K=0.743, 0.899). Conclusion: The MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging can be used to diagnose the airway and vascular abnormity in lung. This technique resembles the ventilation-perfusion scintigraphy. It can provide quantitative functional information and better spatial and temporal resolution, and possesses the value of clinical application

  17. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  18. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  19. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  20. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  1. The value of right lateral decubitus position to decrease artificial defect of cardiac anterior wall in 99Tcm-MIBI SPECT myocardial perfusion imaging for women

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; Wen Guanghua; Liang Weitang; Yu Fengwen; Liu Dejun

    2013-01-01

    Objective: To explore the value of right lateral decubitus position MPI for differentiating myocardial perfusion defect from cardiac anterior wall attenuation artificial defect, caused by breast of woman. Methods: Forty-nine patients(average age (61.5±8.4) years) who had low likelihood of coronary artery disease and had perfusion defect in the anterior wall after exercise stress 99 Tc m -MIBI MPI were included. All underwent supine and right lateral decubitus position during resting SPECT images. The myocardial perfusion SPECT images at left ventricle were reconstructed and were measured by Bull's-eye, based on the counts. Results from both supine position imaging and right lateral decubitus position imaging were compared. Paired t test was used to statistically analyse the data by SPSS 13.0. Results: Compared with supine position, the counts of the anterior, inferior, apex and lateral wall in right lateral decubitus position were significantly higher: (71.30±3.53)% vs (66.50±3.85)%, (70.06±4.45)% vs (65.44±4.16)%, (77.90±3.00)% vs (75.81±4.08)%,(79.30±2.26)% vs (72.60±3.87)% (t=6.731, 5.286, 3.555, 10.885, all P<0.01). The counts of septal wall were significantly lower ((66.60±3.98)% vs (70.06±4.51)%, t=-4.625, P<0.01) in right lateral decubitus position than that in supine position. Among the different regions of anterior wall, the counts of the anterior-middle ((76.40 ± 3.80)% vs (68.60 ± 4.76)%) and anterior-apex region ((77.10±3.24)% vs (69.00±3.54)%) were significantly higher (t=9.916, 8.870, both P<0.01) in right lateral decubitus position than those in supine position, but there was insignificance ((56.94±6.06)% vs (58.50±4.98)%, t=-1.493, P>0.05) at anterior-basal region. The artificial defect of different degrees in anterior wall was observed in all patients in supine position, 23 cases (46.9%, 23/49) showed artificial defect in the anterior-middle region and 16 cases (32.7%, 16/49) in the anterior-apex region. All artificial defect

  2. Assessment of the myocardial perfusion pattern in patients with multivessel coronary artery disease

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Kane, S.A.; Amenta, A.

    1983-01-01

    A total of 42 symptomatic patients with coronary artery disease involving two or three vessels were studied using exercise thallium-201 myocardial scintigraphy. Qualitative analysis of the images predicted multivessel disease in 75% of the patients with two-vessel disease and in 82% of the patients with three-vessel disease. Quantitative analysis of the size of the perfusion defect indicated that approximately 40% of the left ventricular perimeter showed abnormal perfusion pattern during stress in these patients, and there was no significant difference in the size of the defect in patients with two-vessel disease or three-vessel disease (41 +/- 17% vs 42 +/- 14%, respectively, mean +/- SD). The exercise heart rate, exercise ECG response, and severity of narrowing did not correlate with the size of the perfusion defect. Patients with anterior infarction had larger defects in the distribution of the left anterior descending artery than those without infarction. Collaterals offered partial protection during exercise only when they were not jeopardized. This study confirms the value of qualitative analysis of exercise thallium-201 imaging in predicting multivessel disease, and describes a simple method of assessing the extent of perfusion abnormalities during stress in patients with multivessel disease. The results may be important in patient management and prognosis

  3. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    International Nuclear Information System (INIS)

    Noel, Cory V.; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh; Moffett, Brady

    2017-01-01

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  4. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  5. The benefits of prone SPECT myocardial perfusion imaging in reducing both artifact defects and patient radiation exposure; Beneficio da aquisicao de imagem na posicao Prona em perfusao miocardica com SPECT para reducao de artefatos e exposicao do paciente a radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Stathaki, Maria; Koukouraki, Sophia; Papadaki, Emmanouela; Tsaroucha, Angeliki; Karkavitsas, Nikolaos, E-mail: mariast_cha@yahoo.gr [Department of Nuclear Medicine, University Hospital of Heraklion, Crete (Greece)

    2015-10-15

    Background: Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation. Objectives: To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure. Methods: We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the 'gold standard' for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings. Results: Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects. Conclusion: Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed. (author)

  6. Utility of Deep Inspiration Breath Hold for Left-Sided Breast Radiation Therapy in Preventing Early Cardiac Perfusion Defects: A Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Zagar, Timothy M., E-mail: zagar@med.unc.edu [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Kaidar-Person, Orit [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Tang, Xiaoli [Memorial Sloan Kettering Cancer Center, West Harrison, New York (United States); Jones, Ellen E.; Matney, Jason; Das, Shiva K.; Green, Rebecca L. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Sheikh, Arif [Department of Radiology, Columbia University, New York, New York (United States); Khandani, Amir H.; McCartney, William H.; Oldan, Jorge Daniel; Wong, Terence Z. [Department of Radiology, University of North Carolina, Chapel Hill, North Carolina (United States); Marks, Lawrence B. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States)

    2017-04-01

    Purpose: To evaluate early cardiac single photon computed tomography (SPECT) findings after left breast/chest wall postoperative radiation therapy (RT) in the setting of deep inspiration breath hold (DIBH). Methods and Materials: We performed a prospective single-institution single-arm study of patients who were planned for tangential RT with DIBH to the left breast/chest wall (± internal mammary nodes). The DIBH was done by use of a controlled surface monitoring technique (AlignRT, Vision RT Ltd, London, UK). The RT was given with tangential fields and a heart block. Radiation-induced cardiac perfusion and wall motion changes were assessed by pre-RT and 6-month post-RT SPECT scans. A cumulative SPECT summed-rest score was used to quantify perfusion in predefined left ventricle segments. The incidence of wall motion abnormalities was assessed in each of these same segments. Results: A total of 20 patients with normal pre-RT scans were studied; their median age was 56 years (range, 39-72 years). Seven (35%) patients also received irradiation to the left internal mammary chain, and 5 (25%) received an additional RT field to supraclavicular nodes. The median heart dose was 94 cGy (range, 56-200 cGy), and the median V25{sub Gy} was zero (range, 0-0.1). None of the patients had post-RT perfusion or wall motion abnormalities. Conclusions: Our results suggest that DIBH and conformal cardiac blocking for patients receiving tangential RT for left-sided breast cancer is an effective means to avoid early RT-associated cardiac perfusion defects.

  7. Numerical Simulation of Ultrasonic Time Reversal Mirror in a Plate with Defect

    Czech Academy of Sciences Publication Activity Database

    Převorovský, Zdeněk; Krofta, Josef

    2008-01-01

    Roč. 13, č. 3 (2008), s. 1-5 ISSN 1435-4934. [NDT in Progress. Praha, 05.11.2007-07.11.2007] R&D Projects: GA ČR GA106/07/1393; GA ČR GA103/06/1711 Institutional research plan: CEZ:AV0Z20760514 Keywords : defect detection * nonlinear ultrasonic spectroscopy * time reversal mirror Subject RIV: BI - Acoustics http://www.ndt.net/ search /docs.php3?showForm=off&edit=1&MainSource=53&AuthorID=2812

  8. Compression of the Right Pulmonary Artery by a Massive Defects on Pulmonary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Makis, William [Brandon Regional Health Centre, Brandon (Canada); Derbekyan, Vilma [McGill Univ. Health Centre, Montreal (Canada)

    2012-03-15

    A 67 year old woman, who presented with a 2 month history of dyspnea, had a vectilation and perfusion lung scan that showed absent perfusion of the entire right lung scan that showed absent perfusion of the entire right lung with normal ventilation, as well as a rounded matched defect in the left lower lung adjacent to mialine, suspicious for an aortic aneurysm or dissection. CT pulmonary angiography revealed a massive descending aortic aneurysm compressing the right pulmonary artery as well as the left lung parenchyma, accounting for the bilateral perfusion scan defects. We present the Xe 133 ventilation, Tc 99m MAA perfusion and CT pulmonary angiography imaging findings of this rare case.

  9. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  10. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  11. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  12. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  13. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability

    International Nuclear Information System (INIS)

    He Xin; Links, Jonathan M; Frey, Eric C

    2010-01-01

    Quantum noise as well as anatomic and uptake variability in patient populations limits observer performance on a defect detection task in myocardial perfusion SPECT (MPS). The goal of this study was to investigate the relative importance of these two effects by varying acquisition time, which determines the count level, and assessing the change in performance on a myocardial perfusion (MP) defect detection task using both mathematical and human observers. We generated ten sets of projections of a simulated patient population with count levels ranging from 1/128 to around 15 times a typical clinical count level to simulate different levels of quantum noise. For the simulated population we modeled variations in patient, heart and defect size, heart orientation and shape, defect location, organ uptake ratio, etc. The projection data were reconstructed using the OS-EM algorithm with no compensation or with attenuation, detector response and scatter compensation (ADS). The images were then post-filtered and reoriented to generate short-axis slices. A channelized Hotelling observer (CHO) was applied to the short-axis images, and the area under the receiver operating characteristics (ROC) curve (AUC) was computed. For each noise level and reconstruction method, we optimized the number of iterations and cutoff frequencies of the Butterworth filter to maximize the AUC. Using the images obtained with the optimal iteration and cutoff frequency and ADS compensation, we performed human observer studies for four count levels to validate the CHO results. Both CHO and human observer studies demonstrated that observer performance was dependent on the relative magnitude of the quantum noise and the patient variation. When the count level was high, the patient variation dominated, and the AUC increased very slowly with changes in the count level for the same level of anatomic variability. When the count level was low, however, quantum noise dominated, and changes in the count level

  14. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  15. Analysis of perfusion defects by causes other than acute pulmonary thromboembolism on contrast-enhanced dual-energy CT in consecutive 537 patients

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Chaehun

    2012-01-01

    Objective: To assess causes, incidence and patterns of perfusion defects (PDs) on dual-energy perfusion CT angiography (DECTA) in clinically suspected acute pulmonary thromboembolisms (PTE). Materials and methods: Consecutive 537 patients who underwent DECTA for suspicion of PTE were retrospectively reviewed. After excluding patients with possible PTE or unsatisfactory perfusion map quality, 299 patients with 1697 lobes were included. The DECTA (Somatom Definition, Siemens) was performed at 140 kV and 80 kV. Color-coded perfusion images were obtained with a lung PBV application of the workstation software (Syngo Dual Energy). The presence, incidence, three patterns of PDs (wedge-shaped, heterogeneous, and regionally homogeneous), pulmonary diseases, and the matchedness between the PD and the disease extent were studied. Results: 315 of 1697 lobes (18.6%) in 156 of 299 patients (81.3%) showed PDs. Among them, 51 (3%), 257 (15.1%), and 7 (0.4%) lobes had PDs due to vascular, nonvascular, and unidentifiable causes, respectively. Vascular causes include: pulmonary arterial (PA) hypertension (0.7%), extrinsic occlusion of PA by fibrosis (0.6%), PA hypoplasia (0.6%), vasculitis (0.5%), cancer mass compressing PA, venous occlusion, AVM, and pulmonary angiosarcoma. Most of PDs were wedge-shaped and well-matched. Nonvascular causes include: mosaic attenuation (4.1%), emphysema (3.2%), interstitial fibrosis (1.6%), bronchitis (1.4%), GGO (1.2%), cellular bronchiolitis (1%), bronchiectasis, airway obstruction, compensaroty lung hyperinflation, air trapping, cor-pulmonale, bronchopneumonia, physiologic decreased ventilation, and segmental bronchial atresia. Most of PDs showed heterogeneous pattern and were not matched. Conclusions: Various vascular and nonvascular diseases cause PDs on DECTA. Each disease shows different pattern of PD depending on pathophysiology and physiologic compensation.

  16. Nuclear cardiology: Myocardial perfusion and function

    International Nuclear Information System (INIS)

    Seldin, D.W.

    1991-01-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical; two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references

  17. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  18. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  19. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  20. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    International Nuclear Information System (INIS)

    Flacke, S.; Keller, E.; Urbach, H.; Wuellner, U.; Hamzei, F.

    2000-01-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  1. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, S; Keller, E; Urbach, H [Dept. of Radiology, Univ. of Bonn (Germany); Wuellner, U; Hamzei, F [Dept. of Neurology, Univ. of Bonn (Germany)

    2000-02-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  2. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  3. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  4. Relations among impaired coronary flow reserve, left ventricular hypertrophy and thallium perfusion defects in hypertensive patients without obstructive coronary artery disease

    International Nuclear Information System (INIS)

    Houghton, J.L.; Frank, M.J.; Carr, A.A.; von Dohlen, T.W.; Prisant, L.M.

    1990-01-01

    Invasive Doppler catheter-derived coronary flow reserve, echocardiographic measurements of left ventricular hypertrophy and intravenous dipyridamole-limited stress thallium-201 scintigraphy were compared in 48 patients (40 were hypertensive or diabetic) with clinical ischemic heart disease and no or minor coronary artery disease. Abnormal vasodilator reserve (ratio less than 3:1) occurred in 50% of the study group and markedly abnormal reserve (less than or equal to 2:1) occurred in 27%. Coronary vasodilator reserve was significantly lower (2.2 +/- 0.8 versus 3.5 +/- 1.3, p = 0.003) and indexed left ventricular mass significantly higher (152.6 +/- 42.2 versus 113.6 +/- 24.0 g, p = 0.0007) in patients with a positive (n = 11) versus a negative (n = 32) thallium perfusion scan. Coronary flow reserve was linearly related in coronary basal flow velocity as follows: y = -0.17x + 4.59; r = -0.57; p = 0.00002. The decrement in flow reserve was not linearly related to the degree of left ventricular hypertrophy. Abnormal vasodilator reserve subsets found in hypertensive patients were defined on the basis of basal flow velocity, indexed left ventricular mass and clinical factors. In this series, diabetes did not cause a detectable additional decrement in flow reserve above that found with hypertension alone. These findings demonstrate that thallium perfusion defects are associated with depressed coronary vasodilator reserve in hypertensive patients without obstructive coronary artery disease. Left ventricular hypertrophy by indexed mass criteria is predictive of which hypertensive patients are likely to have thallium defects

  5. Value of T1-201 myocardial perfusion scan for predicting prognosis in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yutaka; Tomoda, Haruo [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine; Sugihara, Masami

    1983-05-01

    The extent of Tl-201 perfusion defects was determined in three views by the average ratio of perfusion defects to that of the left ventricle. As the percent Tl-201 defect index increased, the peak value of creatine phosphokinase, the grade of Peel index, incidence of congestion on the initial chest X-ray, and pulmonary artery end-diastolic pressure all gradually increased. In 48 patients followed for 23 months on the average after discharge, the incidence of congestive heart failure and ventricular premature beat also increased. The prognosis was particulary poor in patients who had the percent Tl-201 defect index greater than 40%.

  6. 99mTc-ECD brain SPECT in patients with Moyamoya disease: a reflection of cerebral perfusion status at tissue level in the disease process

    International Nuclear Information System (INIS)

    Kashyap, Raghava; Mittal, Bhagwant Rai; Sunil, Hejjaji Venkataramarao; Bhattacharya, Anish; Singh, Baljinder; Mukherjee, Kanchan Kumar; Gupta, Sunil Kumar

    2011-01-01

    Moyamoya disease is a rare, progressive cerebrovascular disorder caused by intracranial stenosis of the circle of Willis, resulting in successive ischemic events. Computed tomography (CT) and magnetic resonance imaging (MRI) play a major role in diagnosis. The aim of the study was to describe the spectrum of findings on brain SPECT in patients with Moyamoya disease and to compare the findings with other investigations. 99m Tc-ECD SPECT scans of seventeen patients (7 children and 10 adults) were analysed to study the brain perfusion. Features of Moyamoya disease were detected on DSA in 11 patients, CTA in one, MR angiography in one patient. Brain perfusion SPECT analysis showed unilateral perfusion defects in 11 patients, normal perfusion in 2 and bilateral defects in 4 patients. No perfusion defects despite bilateral vascular changes were noted in one patient. Cerebral infarcts were detected on MRI unilaterally in three subjects while multiple infarcts were identified in one. 99m Tc-ECD Brain SPECT showed perfusion defects that were more extensive compared to those detected on MRI. Post acetazolamide studies for assessment of cerebrovascular reserve were done in three patients. Two of them showed good cerebrovascular reserve (>1). Follow-up studies post-surgical procedures (Myo-dura synangiosis) done in two patients showed partial resolution of perfusion defects in the involved areas. Brain perfusion scintigraphy is an important adjunct in evaluation of patients with Moyamoya disease yielding information about the direct end results of the pathology in the vessels and also prognostic information. (author)

  7. Perfusion imaging with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Holman, B.L.; Hill, T.C.

    1987-01-01

    SPECT with perfusion tracers is useful in a number of circumstances: (1) In acute cerebral infarction while the CT scan may be normal for several days after onset of symptoms, the uptake of SPECT perfusion tracers will be altered immediately after the onset of the stroke. Even when the CT scan has become abnormal, the physiologic abnormality may exceed the anatomic abnormality. One may, therefore be able to measure the extent of the reversibly ischemic tissue early enough to justify more agressive therapeutic interventions. (2) For endarterectomy and other surgical and medical therapies serial measurements of regional cerebral perfusion with SPECT may provide a readily available tool to assess their efficacy. (3) SPECT perfusion imaging may become the method of choice for the diagnosis and evaluation of Alzheimer's disease. (4) In patients with epilepsy, the extent and location of the abnormally perfused focus may be important to medical and surgical management. Follow-up examination may be useful in documenting the effectiveness of therapy

  8. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  9. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    Science.gov (United States)

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  10. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  11. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  12. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  13. Quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    Energy Technology Data Exchange (ETDEWEB)

    Miyanaga, Hajime [Kyoto Prefectural Univ. of Medicine (Japan)

    1982-08-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes.

  14. [Are Visual Field Defects Reversible? - Visual Rehabilitation with Brains].

    Science.gov (United States)

    Sabel, B A

    2017-02-01

    local activation of the visual cortex and global reorganisation of neuronal brain networks. Because modulation of neuroplasticity can strengthen residual vision, the brain deserves a better reputation in ophthalmology for its role in visual rehabilitation. For patients, there is now more light at the end of the tunnel, because vision loss in some areas of the visual field defect is indeed reversible. Georg Thieme Verlag KG Stuttgart · New York.

  15. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  16. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  17. Study of lung perfusion in colagenosis

    Energy Technology Data Exchange (ETDEWEB)

    Macedo de Carvalho, A C; Calegaro, J U.M. [Fundacao Hospitalar do Distrito Federal, Distrito Federal (Brazil). Unidade de Medicina Nuclear

    1982-07-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized.

  18. Study of lung perfusion in colagenosis

    International Nuclear Information System (INIS)

    Macedo de Carvalho, A.C.; Calegaro, J.U.M.

    1982-01-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized. (author) [es

  19. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  20. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  1. Demonstration of cerebral abnormalities in cocaine abusers with SPECT perfusion brain scans

    International Nuclear Information System (INIS)

    Nagel, J.S.; Tumeh, S.S.; English, R.J.; Moore, M.; Lee, V.W.; Holman, L.B.

    1989-01-01

    This paper reports I-123 isopropyl iodoamphetamine (IMP) single-photon emission CT (SPECT) brain scans performed on cocaine users to investigate the effects of cocaine on the cerebral perfusion in a manner similar to previous CT, angiographic and positron-emission tomographic (PET) studies. Ten asymptomatic or mildly symptomatic cocaine users, two users with major neurovascular complications, and five normal subjects were studied with IMP SPECT. Rotating-brain images of the cerebral IMP uptake were displayed by using a distance-weighted surface-projection technique and were visually analyzed for focal cortical perfusion deficits. Eleven cocaine users had multiple scattered cortical IMP defects. Frontal lobe defects were most prominent. One user had confluent defects resembling swiss cheese. Concurrent CT scans available in nine patients were negative in seven and showed infarcts in two. No similar focal findings were visible in normals

  2. Influence of ocular perfusion pressure fluctuation on glaucoma

    Directory of Open Access Journals (Sweden)

    Min-Zi Ren

    2015-12-01

    Full Text Available AIM:To investigate the influence of ocular perfusion pressure fluctuation on glaucoma. METHODS:Forty patients with primary open angle glaucoma from January 2013 to June 2015 in our hospital were used as observation group and 40 families were used as control group. Circadian fluctuation of intraocular pressure, blood pressure and ocular perfusion pressure in 24h were determined to obtain systolic ocular perfusion pressure(SOPP, diastolic ocular perfusion pressure(DOPPand mean ocular perfusion pressure(MOPP. Pearson linear correlation was used to analyze the correlation of circadian MOPP fluctuation with cup-disc ratio, mean defect(MDand the picture standard deviation(PSD. RESULTS:The fluctuation of MOPP, SOPP and DOPP of observation group were significantly higher than those of control group(Pr=-0.389, 95%CI:-0.612~-0.082; P=0.011, was positively correlated with PSD(r=0.512, 95%CI:0.139 ~0.782; P=0.008; no correlation was found between it and the vertical cup-disc ratio(r=0.115, 95%CI:0.056~0.369; P=0.355. CONCLUSION:Ocular perfusion pressure fluctuations in patients with primary open angle glaucoma may reflect the severity of the disease and may make the situation aggravating. Therefore through perfusion pressure monitor in 24h may help us understand the ocular blood flow and the development of primary open-angle glaucoma.

  3. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  4. Hyperventilation, cerebral perfusion, and syncope

    DEFF Research Database (Denmark)

    Immink, R V; Pott, F C; Secher, N H

    2014-01-01

    dioxide (PaCO2) and oxygen (PaO2) partial pressures so that hypercapnia/hypoxia increases and hypocapnia/hyperoxia reduces global cerebral blood flow. Cerebral hypoperfusion and TLOC have been associated with hypocapnia related to HV. Notwithstanding pronounced cerebrovascular effects of PaCO2...... the contribution of a low PaCO2 to the early postural reduction in middle cerebral artery blood velocity is transient. HV together with postural stress does not reduce cerebral perfusion to such an extent that TLOC develops. However when HV is combined with cardiovascular stressors like cold immersion or reduced...... cardiac output brain perfusion becomes jeopardized. Whether, in patients with cardiovascular disease and/or defect, cerebral blood flow cerebral control HV-induced hypocapnia elicits cerebral hypoperfusion, leading to TLOC, remains to be established....

  5. A quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    International Nuclear Information System (INIS)

    Miyanaga, Hajime

    1982-01-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes. (J.P.N.)

  6. Assessment of non-typical worsening of myocardial perfusion in rest in comparison to stress in 99mTc-MIBI SPECT studies. Preliminary report

    International Nuclear Information System (INIS)

    Dabrowski, A.; Szumilak, B.; Wnuk, J.; Konieczna, S.; Teresinska, A.

    2002-01-01

    Worsening of regional rest perfusion in comparison to stress perfusion, observed in a few percentage of myocardial perfusion 99m Tc-MIBI SPECT studies, does not have an easy clinical interpretation. Also, no reports evaluating the relationship between worsening and technical SPECT study conditions are available. The goal of our study is: 1) to assess the reproducibility of this non-typical effect - by repeating the rest study on separate day after new MIBI injection; 2) to assess reproducibility of this effect in rest perfusion images performed at different time points after one MIBI injection; 3) to propose the most probable clinical explanation for this effect. Up to now, 20 patients (100 predicted altogether) with rest perfusion worsening in routine stress-rest 99m Tc-MIBI SPECT perfusion imaging were studied. The group was clinically in homogeneous (7 patients with suspected coronary artery disease (CAD), 4 patients with CAD and no myocardial infarction (MI), 8 patients after MI, and 1 patient with developmental anomaly). Within 14 days, rest study was repeated, with data acquisition performed at 1 h and 3 hrs after MIBI injection. Regional myocardial perfusion was evaluated qualitatively, in 17 segments of the LV and compared among stress and all the three rest (BAD-I, BAD-II, BAD-III) studies. In 175 segments there was perfusion worsening in at least one of the three rest studies. In the highest percentage of these segments (n=53, 30%, ), worsening was present in all rest studies. Among stress defects with perfusion worsening in BAD-I, the highest percentage (55%, ) presented worsening also in BAD-II (performed after separate injection of MIBI, but like in BAD-I also 1 h after injection), significantly lower percentage - persistent defect in BAD-II (25%, ), and some smaller percentage - transient defect in BAD-II (20%, ). In segments with perfusion worsening present in one of the rest studies, our preliminary results show: 1) the highest probability of

  7. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  8. Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction

    International Nuclear Information System (INIS)

    Park, Soon Ah; Kim, Dae Weung; Kim, Chang Guhn; Jeong, Jin Won; Kim, Nam Ho; Yun, Kyeong Ho

    2009-01-01

    This study was performed to investigate the clinical significance of reverse redistribution (RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography (SPECT) in patients with acute myocardial infarction after revascularization. A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography (CAG) were performed 9 months later. On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments (31%) and in 43 patients (64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR (p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR (p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium

  9. Transient mitral regurgitation: An adjunctive sign of myocardial ischemia during dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Lette, J.; Gagnon, A.; Lapointe, J.; Cerino, M.

    1989-01-01

    A patient developed transient exacerbation of a mitral insufficiency murmur and a reversible posterior wall perfusion defect during dipyridamole-thallium imaging. Coronary angiography showed significant stenoses of both the right and the circumflex coronary arteries that supply the posterior papillary muscle. Cardiac auscultation for transient mitral incompetence, a sign of reversible papillary muscle dysfunction, is a simple and practical adjunctive test for myocardial ischemia during dipyridamole-thallium imaging. It may confirm that an isolated reversible posterior wall myocardial perfusion defect is truly ischemic in nature as opposed to an artifact resulting from attenuation by the diaphragm

  10. Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.

    Science.gov (United States)

    Fuglevand, A J; Segal, S S

    1997-10-01

    Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.

  11. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  12. Comparison of ventilation-perfusion single-photon emission computed tomography (V/Q SPECT) versus dual-energy CT perfusion and angiography (DECT) after 6 months of pulmonary embolism (PE) treatment

    Energy Technology Data Exchange (ETDEWEB)

    Meysman, M., E-mail: marc.meysman@uzbrussel.be [Respiratory Division, Department of Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Everaert, H., E-mail: nucgeth@gmail.com [Department of Nuclear Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Buls, N., E-mail: nico.buls@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Nieboer, K., E-mail: koenraad.nieboer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Mey, J. de, E-mail: Johan.deMey@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium)

    2015-09-15

    Highlights: • Incomplete resolution of pulmonary emboli occurs frequently. • Residual V/Q-SPECT defects correspond in the majority of cases with defects seen on DECT. • Some (11.1%) defects on V/Q-SPECT are not present on comparable DECT images. - Abstract: Background: The natural evolution of treated symptomatic pulmonary embolism shows often incomplete resolution of pulmonary thrombi. The prevalence of perfusion defects depend on the image modality used. This study directly compares V/Q SPECT with DECT. Methods: A single-center prospective observational cohort study of patients with intermediate risk PE, reassessed at the end of treatment with V/Q SPECT. Abnormal V/Q SPECT images were compared with DECT. Results: We compared DECT en V/Q SPECT in 28 consecutive patients with persistent V/Q mismatch on V/Q SPECT, 13 men and 15 woman, mean age 60 (+17), range 23–82 year. One patient was excluded from the final analysis due to inferior quality DECT. In 18/27 (66.7%) the results were concordant between CTPA (persistent embolus visible), DECT (segmentary defects on iodine map) and V/Q SPECT (segmentary ventilation–perfusion mismatch). In 3/18 (11.1% of the total group) the partialy matched V/Q SPECT defect could be explained on DECT lung images by lung infarction. In 6/27 (22.1%) only hypoperfusion was seen on DECT iodine map. In 3/27 (11.1%) results were discordant between V/Q SPECT and DECT images. Conclusion: Six months after diagnosis of first or recurrent PE, residual pulmonary perfusion-defects encountered on V/Q-SPECT corresponds in the majority of patients with chronic thromboembolic disease seen on DECT. In 22.1% of patients V/Q SPECT mismatch only corresponds with hypoperfusion on iodine map DECT scan. Some (11.1%) of the chronic thromboembolic lesions seen on V/Q SPECT can not be explained by DECT results.

  13. Defect thiospinels: a new class of reversible cathode material

    Science.gov (United States)

    James, A. C. W. P.; Goodenough, J. B.

    1989-05-01

    The defect thiospinel Cu 0.07[Ti 2]S 4 was prepared by low-temperature oxidative extraction of copper from Cu[Ti 2]S 4. Up to two equivalents of lithium can be inserted into Cu 0.07[Ti 2]S 4 reversibly with fast electrochemical kinetics at room temperature; the defect thiospinel is, therefore, a highly promising alternative to layered TiS 2 as a cathode material for lithium secondary batteries. Samples of Cu 1- x [Ti 2]S 4 (0⩽ x ⩽ 0.93) and Li xCu 0.07[Ti 2]S 4 (0 < x < 2) were prepared and characterised by 65Cu and 7Li solid-state NMR, neutron powder diffraction, and electrochemical measurements. Cu 0.07[Ti 2]S 4 is a semimetal with the residual copper located on the normal spinel A-cation sites. The lithium in Li xCu 0.07[Ti 2]S 4 is located only in the 16c octahedral sites of the spinel framework at all lithium compositions. The open-circuit voltage of Li xCu 0.07[Ti 2]S 4versus lithium metal is nearly identical to that of layered Li xTiS 2 over the whole lithium-composition range. The chemical diffusion constant of lithium in Li xCu 0.07[Ti 2]S 4 (0.5 ⩽ x⩽ 1.5) was found to be 1 × 10 -9 cm 2 s -1, which is comparable with that in layered Li xTiS 2.

  14. Basal hyperaemia is the primary abnormality of perfusion in Takotsubo cardiomyopathy

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Ahtarovski, Kiril Aleksov; Bang, Lia Evi

    2015-01-01

    AIMS: Takotsubo cardiomyopathy (TTC) is characterized by acute completely reversible regional left ventricle (LV) akinesia and decreased tracer uptake in the akinetic region on semi-quantitative perfusion imaging. The latter may be due to normoperfusion of the akinetic mid/apical area and basal...... hyperperfusion. Our aim was to examine abnormalities of perfusion in TTC, and we hypothesized that basal hyperperfusion is the primary perfusion abnormality in the acute state. METHOD AND RESULTS: Twenty-five patients were diagnosed with TTC due to (i) acute onset of symptoms, (ii) typical apical ballooning......-on follow-up. Patients initially had severe heart failure, mid/apical oedema but no infarction, and a rise in cardiac biomarkers. On initial perfusion PET imaging, eight patients appeared to have normal, whereas 17 patients had impaired LV perfusion. In the latter, flow in the basal region was increased...

  15. The reverse sural artery fasciomusculocutaneous flap for small lower-limb defects: the use of the gastrocnemius muscle cuff as a plug for small bony defects following debridement of infected/necrotic bone.

    Science.gov (United States)

    Al-Qattan, M M

    2007-09-01

    The reverse sural artery fasciomusculocutaneous flap is a modification of the original fasciocutaneous flap in which a midline gastrocnemius muscle cuff around the buried sural pedicle is included in the flap. This modification was done to improve the blood supply of the distal part of the flap, which is harvested from the upper leg. The aim of this paper is to demonstrate that there is another important advantage of the modified flap: the use of the muscle cuff as a "plug" for small lower limb defects following debridement of infected/necrotic bone. A total of 10 male adult patients with small complex lower-limb defects with underlying bone pathology were treated with the modified flap using the muscle component to fill up the small bony defects. The bony pathology included necrotic exposed bone without evidence of osteomyelitis or wound infection (n = 1), an underlying neglected tibial fracture with wound infection (n = 4), and a sinus at the heel with underlying calcaneal osteomyelitis (n = 5). Primary wound healing of the flap into the defect was noted in all patients. No recurrence of calcaneal osteomyelitis was seen and all tibial fractures united following appropriate orthopedic fixation. It was concluded that the reverse sural artery fasciomusculocutaneous flap is well suited for small complex lower-limb defects with underlying bone pathology.

  16. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  17. MRI findings in multifetal pregnancies complicated by twin reversed arterial perfusion sequence (TRAP)

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Carolina V.A.; Kline-Fath, Beth M.; Linam, Leann E.; Calvo Garcia, Maria A.; Rubio, Eva I. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lim, Foong-Yen [Cincinnati Children' s Hospital Medical Center, Division of Pediatric Surgery, Cincinnati, OH (United States)

    2011-06-15

    Twin reversed arterial perfusion sequence (TRAP) is a rare complication in multifetal monochorionic pregnancies in which a normal ''pump'' twin provides circulation to an abnormal acardiac co-twin, resulting in high-output cardiac dysfunction in the pump twin. To define fetal MRI findings of TRAP sequence. Fetal MR images were retrospectively reviewed in 35 pregnancies complicated by TRAP sequence. Abnormalities of the pump twin, acardiac twin, umbilical cord, placenta and amniotic fluid were reviewed. Acardiac twins were classified as: acephalus (51%), anceps (40%), amorphus (9%), acormus (0%). Common findings in acardiac twins include subcutaneous edema (77%), absent cardiac structures (86%), absent or abnormal thoracic cavity (100%), abnormal abdominal organs (100%), superior limbs absent (46%) or abnormal (51%), and inferior limbs present but abnormal (83%). There were pump twin findings of cardiac dysfunction in 43% and intracranial ischemic changes in 3%. Umbilical cord anomalies were present in 97%. Acardiac twins present with a predictable pattern of malformation with poorly developed superior structures, more normally formed inferior structures and absent or rudimentary heart. Although usually absent, abnormal heart structures can be seen and do not exclude TRAP sequence. Pump twins are commonly normal with exception of findings of cardiac dysfunction and possible brain ischemia. (orig.)

  18. Influence of defect size and localization on the engagement of reverse Hill-Sachs lesions.

    Science.gov (United States)

    Moroder, Philipp; Runer, Armin; Kraemer, Manuel; Fierlbeck, Johann; Niederberger, Alfred; Cotofana, Sebastian; Vasvari, Imre; Hettegger, Bernhard; Tauber, Mark; Hurschler, Christof; Resch, Herbert

    2015-03-01

    Reverse Hill-Sachs (RHS) lesions can cause recurrent posterior shoulder instability because of engagement with the posterior glenoid rim; however, the effect of defect size and localization have yet to be determined. Both size and localization are critical for the engagement of an RHS defect with the posterior glenoid rim. Controlled laboratory study. Ten RHS defects with predefined extent and localization were created through an anterolateral rotator cuff sparing approach in 10 fresh-frozen cadaveric shoulder specimens using a custom-made saw guide. Computed tomography scans of all specimens were completed, and standardized measurements were performed to determine the size (alpha angle) and localization (beta angle) of the defect as well as a combination of both parameters (gamma angle). Internal rotation motions were imposed on the shoulder joint in different arm positions and with varying amount of posterior translation by means of a robot-assisted shoulder simulator. The association between engagement of the defects and the defined parameters (alpha, beta, and gamma angles) was analyzed. In 0° of abduction, a cutoff value between engaging and nonengaging defects of 37.5° for the alpha angle (100% sensitivity; 75% specificity; area under the curve [AUC], 0.875; P = .055) and 36.5° for the beta angle (100% sensitivity; 25% specificity; AUC, 0.708; P = .286) was determined. The gamma angle showed the highest discriminatory power (AUC, 0.938; P = .025) with a cutoff value of 85.5° rendering 100% sensitivity and 75% specificity in the prediction of engagement. An increase in the applied posterior translation force decreased the degrees of internal rotation necessary before engagement occurred. No engagement occurred during internal rotation with the arm in 60° of abduction or 60° of flexion. The size and localization of RHS defects are both critical factors for engagement. The combination of both parameters in terms of the gamma angle measurement might be a

  19. Regional ventilation/perfusion mismatch pattern in patient with Swyer James (MacLeod′s syndrome

    Directory of Open Access Journals (Sweden)

    Sait Sager

    2014-01-01

    Full Text Available Swyer James (McLeod′s syndrome (SJMS is an uncommon disease, which occurs as a result of childhood bronchiolitis obliterans. Patients may not be diagnosed until later in their life. A 46-year-old man underwent ventilation/perfusion scintigraphy for acute onset of dyspnea. The scan showed markedly diminished ventilation and perfusion unilaterally on the right middle and inferior lobes. However, mismatched ventilation-perfusion pattern was shown on the upper right lobe, which was consistent with pulmonary embolism. Unilaterally matched ventilation/perfusion defect can see in SJMS in lung scintigraphy; however, when pulmoner embolism may accompany, scintigraphy should be carefully examined.

  20. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  1. Gated SPECT evaluation of myocardial perfusion defects and left ventricular function in chronic atrial fibrillation (CAF) patients - a prevalence study between a General Hospital (GH) and a referral Cardiology Hospital (CH)

    International Nuclear Information System (INIS)

    Rocha, G.; Guimaraes, M.; Marroni, B.; Zagoury, E.; Sprinz, C.; Andrea, S.; Louzada, A.; Ludwig, R.; Graef, C.

    2002-01-01

    Aims: to evaluate myocardial perfusion defects (MPD) prevalence and left ventricular function in CAF patients from a distinct referral basis (a GH and CH populations). Materials and Methods: a retrospective cross-sectional survey including 171 CAF (43 from GH and 128 from CH) and 5415 control patients (2222 from GH and 3193 from CH) submitted to rest/stress myocardial perfusion gated SPECT with Tc99m-MIBI. The following items were collected from CAF patients: the percentage of patients with MPD, the type (fixed, reversible or mixed) and number of segments with MPD and left ventricular ejection fraction (LVEF). The control patients percentage of MPD, their type and number were also collected. Results: CAF from GH and CH were not significantly different in the number of patients with MPD, mean number of segments affected, and LVEF. In GH patients, the CAF group had more segments with MPD (2,4x1,6 p<0,01) and lower LVEF (37%x52% p<0,01) than control group. CAF patients from CH also showed lower LVEF (40%x58% p<0,01) and more fixed MPD (40%x18% p<0,01) than their control group population. Conclusion: our data showed similar prevalence of MPD and reduced LVEF values between CAF patients from a GH and referral CH. The CAF group from CH seemed to have more fixed MPD perhaps reflecting more severe coronary artery disease population or referral bias. The data appears to support the evaluation of myocardial ischemia as a part of CAF possible etiologies. Caution is advised in LVEF evaluation of CAF patients due to increased variability of R-R interval

  2. Late gadolinium uptake demonstrated with magnetic resonance in patients where automated PERFIT analysis of myocardial SPECT suggests irreversible perfusion defect

    International Nuclear Information System (INIS)

    Rosendahl, Lene; Blomstrand, Peter; Ohlsson, Jan L; Björklund, Per-Gunnar; Ahlander, Britt-Marie; Starck, Sven-Åke; Engvall, Jan E

    2008-01-01

    Myocardial perfusion single photon emission computed tomography (MPS) is frequently used as the reference method for the determination of myocardial infarct size. PERFIT ® is a software utilizing a three-dimensional gender specific, averaged heart model for the automatic evaluation of myocardial perfusion. The purpose of this study was to compare the perfusion defect size on MPS, assessed with PERFIT, with the hyperenhanced volume assessed by late gadolinium enhancement magnetic resonance imaging (LGE) and to relate their effect on the wall motion score index (WMSI) assessed with cine magnetic resonance imaging (cine-MRI) and echocardiography (echo). LGE was performed in 40 patients where clinical MPS showed an irreversible uptake reduction suggesting a myocardial scar. Infarct volume, extent and major coronary supply were compared between MPS and LGE as well as the relationship between infarct size from both methods and WMSI. MPS showed a slightly larger infarct volume than LGE (MPS 29.6 ± 23.2 ml, LGE 22.1 ± 16.9 ml, p = 0.01), while no significant difference was found in infarct extent (MPS 11.7 ± 9.4%, LGE 13.0 ± 9.6%). The correlation coefficients between methods in respect to infarct size and infarct extent were 0.71 and 0.63 respectively. WMSI determined with cine-MRI correlated moderately with infarct volume and infarct extent (cine-MRI vs MPS volume r = 0.71, extent r = 0.71, cine-MRI vs LGE volume r = 0.62, extent r = 0.60). Similar results were achieved when wall motion was determined with echo. Both MPS and LGE showed the same major coronary supply to the infarct area in a majority of patients, Kappa = 0.84. MPS and LGE agree moderately in the determination of infarct size in both absolute and relative terms, although infarct volume is slightly larger with MPS. The correlation between WMSI and infarct size is moderate

  3. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    Science.gov (United States)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-11-21

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  4. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects

    International Nuclear Information System (INIS)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-01-01

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest 99m Tc-sestamibi/ 123 I-BMIPP imaging protocol in place of the commonly used sequential rest/stress 99m Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  5. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  6. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  7. Defect mediated reversible ferromagnetism in Co and Mn doped zinc oxide epitaxial films

    Energy Technology Data Exchange (ETDEWEB)

    Mal, Siddhartha; Nori, Sudhakar; Narayan, J. [Department of Material Science and Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Mula, Suhrit [Department of Material Science and Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Department of Metallurgical and Materials Engineering, National Institute of Technology, Rourkela 769008 (India); Prater, J. T. [Materials Science Division, Army Research Office, Research Triangle Park, North Carolina 27709 (United States)

    2012-12-01

    We have introduced defects in ZnO (undoped and doped with Co and Mn) epitaxial thin films using laser irradiation from nanosecond laser pulses and thermal annealing in oxygen ambient. In contrast to the as grown samples, the laser irradiated films show a significant increase in conductivity, enhancement in UV emission, while maintaining the same wurtzite crystal structure. Room-temperature ferromagnetism (RTFM) is observed in laser-irradiated samples, which increased with the number of laser pulses up to a certain value where magnetic moment saturates. The induced ferromagnetism as well as the enhanced electrical conductivity can be reversed with thermal annealing in oxygen ambient. The magnetization in Co and Mn doped films was found to be strong function of growth conditions and defect concentration. X-ray diffraction and optical absorption experiments suggested a 2+ valance state and tetrahedral coordination for both Co and Mn ions. There is a simultaneous increase in n-type electrical conductivity with the number of laser pulses and continue to exhibit semiconducting behavior in both undoped and doped films. The saturation magnetization was found to be 0.08 {mu}{sub B}/Co and 0.05 {mu}{sub B}/Mn, much lower than 3.0 {mu}{sub B}/Co and 5.0 {mu}{sub B}/Mn, indicating the prominent role of intrinsic defects in RTFM with some contribution from Co{sup 2+}-oxygen vacancy complexes. We propose a unified mechanism based upon introduction of intrinsic defects to explain RTFM and n-type conductivity enhancements during pulsed laser and thermal annealing.

  8. Thallium - 201 miocardial perfusion scintigraphy in patients with mitral valve prolapse, with and without coronary artery disease

    International Nuclear Information System (INIS)

    Moraes, A.G. de; Sousa, J.E.M.R.; Thom, A.F.; Martins, L.R.F.; Meneghelo, R.S.; Pimentel Filho, W.A.; Marioni Filho, H.; Gimenes, V.M.L.; Pontes Junior, S.C.

    1981-01-01

    Thirty patients with precordial pain and mitral valve prolapse diagnosed by cineangiography and M-mode echocardiography were submitted to Thallium-201 myocardial stress perfusion scintillography. They were divided into two groups: group I - eighteen patients with mitral valve prolapse and normal coronary arteries, of which ten presented positive exercise stress test (55.6%); eight patients had a negative exercise test. Thallium-201 myocardial stress perfusion scintillagraphy was normal in 14 (77.8%) patients, and four with positive stress perfursion scintillography, (three with inferior perfusion defects and one with a lateral one); group II - twelve patients with mitral valve prolapse and severe coronary artery disease (stenosis >= 60% in at least one main vessel of the coronary circulation), of which nine presented positive exercise stress test (75%) and three negative. Thallium-201 exercise myocardial perfusion scintillography was abnormal in nine (75%), six with stress induced ischemia and three with resting defect. Myocardial perfusion scintillography with Thallium-201 was more sensitive to detect the presence of coronary artery disease in patients with mitral valve prolapse (MVP) than the exercise stress test in spite of the fact that a small number of patients (22%) with MVP and normal coronary arteries exhibited abnormal myocardial stress perfusion during scintillography. (Author) [pt

  9. Evaluation of patients with coronary artery disease during exercise: the relation between extent of disease and perfusion deficit

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.; Iskandrian, A.S.

    1984-01-01

    The purpose of this study was to assess the relation between the extent of coronary artery disease (CAD) and size of exercise-induced myocardial hypoperfusion in 79 patients with angiographically documented CAD. None of the patients had Q-wave myocardial infarction. Fifty patients had one-vessel disease, ten had two-vessel disease, and 19 patients had three-vessel or left main disease. From a scintigraphic functional standpoint, patients were classified into two groups: 28 patients (35%) had large perfusion defects and 51 patients (65%) had small defects. The size of the thallium-201 perfusion defect during exercise was assessed as the perimeter of the defect in each projection expressed as a percentage abnormality of the total left ventricular perimeter in that projection. The average abnormality from the three projections was used in the final analysis. Eleven patients with large defects (39%) had one-vessel disease and 12 patients with small defects (24%) had multivessel disease. Stepwise multivariate discriminate analysis identified the number of diseased vessels (F . 13.9), the change in systolic blood pressure from rest to exercise (F . 10.8), the exercise heart rate (F . 9.1), and exercise electrocardiographic response (F . 7.8) as significant associates of the size of the perfusion defect (predictive accuracy . 70%). We conclude that the size of hypoperfused myocardium during exercise is variable in patients with CAD. Discriminate analysis identified the extent of CAD, exercise heart rate, change in systolic pressure from rest to exercise, and exercise electrocardiographic response as significant associates of the size of the defect

  10. Myocardial function and perfusion in the CREST syndrome variant of progressive systemic sclerosis. Exercise radionuclide evaluation and comparison with diffuse scleroderma

    International Nuclear Information System (INIS)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.; Owens, G.R.; Steen, V.D.; Rodnan, G.P.

    1984-01-01

    Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patients with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease

  11. Optimization of perfusion studies using Atropine

    International Nuclear Information System (INIS)

    Alvarado, A.N.; Valle, V.M.; Montoya, M.J.; Eskenazi, E.S.; Montiel, M.L.; Cueto, C.C.

    2002-01-01

    The studies of myocardial perfusion require an adequate stress; exercise or pharmacological. Every day, more pharmacological studies are performed, specially in some group of patients (women, AMI, etc). There some drugs that are used for this purpose, as adenosine and dobutamine. However, their cost and the lack of availability and infrastructure in our country do not allow there routinely use. We performed dipyridamol as a pharmacological stress, however in some patients there is a doubt regarding if the pharmacological effect was adequate. Atropine is a drug that is frequently used for different purpose and it is well know its tachycardic response. We present and alternative technique, using dipyridamol-atropine as a protocol of stress perfusion study. Our goal was to correlate the standard dipyridamol -thallium perfusion study and the dipyridamol -atropine-perfusion in patients with chronic coronary disease. We evaluated 6 patients (5 males) with stable angina and chronic coronary disease. A standard dipyridamol-thallium study was performed in all of them. Dipyridamole was administered intravenously at a rate of 0.14 mg/kg/min over 6 min for a total of 0.84 mg/kg body weight. Blood pressure, heart rate, EKG and symptoms were monitored before, during and after the pharmacological infusion. Two minutes after the infusion was completed, the radiotracer was injected intravenously. In the next 6 months, without any modification of the clinical situation (symptoms and therapy) a new dipyridamol study was performed, using 1 mg of atropine after the administration of dipyridamol. There were no differences in the collateral effects and we observed and average increase of 30% in the heart rate in relation with the study using dipyridamol alone. The addition of atropine to the standard dipyridamol perfusion study is safe, cheaper and improved the detection of perfusion defects in patients with coronary artery disease

  12. Diabetes patients show different time-course of myocardial perfusion improvement after coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Lee, J. J.; Seok, J. W.; Eo, J. S.

    2005-01-01

    Diabetes mellitus is an independent risk factor of cardiovascular disease. Diabetes is known to cause microangiopathy. The microangiopathy is hardly detectable on the coronary angiography. Myocardial perfusion imaging shows the resultant perfusion status which reflects the microangiopathy. For patients who underwent revascularization, the microangiopathy could affect the myocardial perfusion improvement. Diabetes patients probably experience the different myocardial perfusion improvement as compared to the non-diabetes patients although they have similar angiographic findings. The aim of this study is to find out whether there is a time-course difference of perfusion improvement between the diabetes and non diabetes patients who showed patent angiographic findings after coronary artery grafting surgery (CABG). A total of 129 patients who underwent coronary artery bypass grafting surgery were enrolled in this study. Myocardial SPECTs performed at previous, short-term (3 month), and mid-term (1 year) to CABG. One-year follow up angiography was done 411±121 days after surgery. Graft patency was determined according to the FitzGibbon et al. Segments were assigned to vascular territories using a 20 segment model. The segments of excellent patency were included in this study. Time course differences of concerned segments were analyzed using RMANOVA. The number of segments enrolled was 764 of diabetes and 1083 of non-diabetes. At short-term follow up, reversibility score was 2.8±8.1% in diabetes and 0.3±7.5% in non-diabetes. At long-term follow up, reversibility score was 1.8±8.0% in diabetes and 0.1±7.3% in non-diabetes. The time-course of reversibility score was significantly different between the diabetes and non diabetes (p<0.001) Diabetic segments showed high residual reversibility score than non-diabetic segments after CABG although the angiographic finding was patent in both groups. This result is maybe attributable to microangiopathy induced by diabetes

  13. Characteristics of myocardial perfusion imaging and coronary artery angiography in patients of NIDDM complicated with AMI

    International Nuclear Information System (INIS)

    Zhao Peiqin; Zhao Jinhua; Qin Mingzhao; Dai HaoJie; Zhang Runwu; Xiao Fen

    2001-01-01

    Objective: To investigate the characteristic changes of myocardial perfusion imaging and coronary artery angiography in patients of acute myocardial infarction (AMI) with underlined type 2 diabetes mellitus. Methods: 25 type 2 diabetes mellitus patients were enrolled for having clinical manifestation of AMI. Ten inpatients with AMI of simple coronary heart disease origin were served as controls. All subjects underwent both myocardial perfusion imagings (resting and nitroglycerine invention) and coronary artery angiography. Results: Compared to controls (40%), type 2 diabetes mellitus + AMI group had higher rate of multivessel disease (60%). For type 2 diabetes mellitus + AMI patients, 129/400 segments (32.25%) showed fixed defect, 25/160 segments (15.62%) in controls. Conclusions: For type 2 diabetes mellitus + AMI group, myocardial perfusion defects are widely distributed and multivessel or severe stenosis is more often presented. Good correlation exists between abnormal segments and angiographic lesions in both the number of segments involved and the severity of the lesions. Radionuclide myocardial perfusion is therefore considered a useful screening test not inferior to angiography, especially for those who are not tolerant enough to undergoing angiography

  14. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    Directory of Open Access Journals (Sweden)

    Daniela Muenzel

    Full Text Available OBJECTIVE: To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI by using motion compensation and a spatio-temporal filter. METHODS: Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT. Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved. Three datasets for each patient were generated: (i original data (ii motion compensated data and (iii motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. RESULTS: The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. CONCLUSION: The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  15. Visceral Perfusion Scintigraphy with {sup 131}I-Labelled Albumin Macroaggregates

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, H.; Yamada, H.; Kitani, K.; Nagatani, M.; Takeda, T.; Migita, T.; Iio, M; Kameda, H. [University of Tokyo, Tokyo (Japan)

    1969-05-15

    The blood supply through the hepatic artery, superior mesenteric artery and portal vein to the visceral organs was studied in 60 cases of various hepatic disorders by scintigraphy after the selective introduction of {sup 131}I MAA by means of visceral arterial catheterization or percutaneous splenic puncture. A comparison of the radioactivities of the liver and the spleen after celiac arterial infusion (celiac perfusion scanning) indicated how much blood in the celiac artery was distributed to the two major arterial branches - the hepatic and splenic. Dominant perfusion was found through the hepatic branch in liver cirrhosis, whereas significantly dominant splenic blood perfusion was found in idiopathic non-cirrhotic portal hypertension. This remarkable contrast of the mode of celiac perfusion in two disorders indicated the etiological difference of these diseases. In malignant neoplasm of the liver, the dominant or exclusive celiac arterial perfusion was found in the tumour region. In these cases, liver scanning by the splenic injection of MAA (portal perfusion scanning) delineated the tumour region as a negative defect similar to the conventional {sup 198}Au colloid scanning. Consequently, from these two perfusion scintigrams the 'key and key-hole' pattern was demonstrated. It was concluded that a neoplastic lesion, primary or metastatic, has the predominant blood supply through the hepatic artery rather than through the portal vein. Celiac perfusion scanning of liver cystosis revealed multiple negative defects. This information was useful for differentiating a malignant tumour, which is usually impossible by conventional liver scanning. Celiac perfusion scanning was also useful for the diagnosis of arterial venous communication. In one case of liver .cancer with cirrhosis and another case with stomach varices, the arterial-v.enous communication was indicated by the appearance of the lung contour in the celiac perfusion scan. In both cases, the combined presence

  16. Pulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department

    Directory of Open Access Journals (Sweden)

    J. G. Santos

    2016-01-01

    Full Text Available Introduction: Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE. Acquiring tomographic images (V/QS-SPECT is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. Patients and methods: We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95CI for the respective difference. Results: We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be −0.75 (95CI of −1.0 to −0.5; p-value = 9.6 × 10−7, expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. Discussion: The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. Conclusion: V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up. Keywords: Pulmonary thromboembolism, Lung, Scintigraphy, Single-photon emission-computed tomography (SPECT

  17. Perfusion imaging using rubidium-82 ((82)Rb) PET in rats with myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, Andreas Ettrup; Ghotbi, Adam Ali; Bodholdt, Rasmus Poul

    2017-01-01

    Assessing myocardial perfusion using 82Rb-PET is emerging as a valuable clinical tool.1,2 The rapid decay (T½ = 76 s) allows for absolute quantification of both rest and stress perfusion within 30 minutes. In addition to evaluation of epicardial disease with perfusion defects, also evaluation...... of balanced coronary and small vessel disease is possible. For further evaluation of how 82Rb-PET can be used clinically, pre-clinical application of the method would be valuable. However, so far no data on the use of 82Rb-PET in small animals have been published nor has the use of 82Rb-PET, to the best...

  18. Specific perfusion pattern in stress 201Tl myocardial scintigraphy of left main coronary artery disease

    International Nuclear Information System (INIS)

    Wakasugi, Shigetoshi; Shibata, Nobuhiko; Kobayashi, Tohru; Fudemoto, Yoshiyuki; Hasegawa, Yoshihisa; Nakano, Shunichi

    1986-01-01

    The usefulness of stress 201 Tl myocardial scintigraphy for identifying left main coronary artery disease was evaluated with data from 23 patients with 50% or more narrowing of the left main coronary artery and 56 patients with 75% or more narrowing of the major coronary arteries but without left main coronary artery involvement (no left main coronary artery disease). Quantitative evaluation of stress perfusion scintigrams in all five patients with narrowing of the left main coronary artery of 90% or more showed a characteristic perfusion pattern (left main pattern) of extensive homogeneous defect over the whole anterolateral segment and simultaneous defects in all radii of the high anteroseptal and high posterolateral segments. On the other hand, such a perfusion pattern was noted in only 1 of 18 patients with less than 90% stenosis of the left main coronary artery and in only 1 of 56 patients with no left coronary artery disease. (orig.)

  19. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Nuutinen, Juho; Liu, Yawu; Laakso, Mikko P.; Karonen, Jari O.; Vanninen, Esko J.; Kuikka, Jyrki T.; Aronen, Hannu J.; Vanninen, Ritva L.

    2009-01-01

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and 99m Tc-labeled ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. 99m TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  20. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nuutinen, Juho [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Liu, Yawu; Laakso, Mikko P. [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland); Karonen, Jari O. [Mikkeli Central Hospital, Department of Radiology, Mikkeli (Finland); Vanninen, Esko J. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Kuikka, Jyrki T. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Niuvanniemi Hospital, Kuopio (Finland); Aronen, Hannu J. [University of Turku, Department of Radiology, Turku (Finland); Vanninen, Ritva L. [Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland)

    2009-10-15

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and {sup 99m}Tc-labeled ethylcysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. {sup 99m}TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  1. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  2. Homocysteine plasma levels in patients suspected coronary artery disease: Relation to myocardial perfusion image

    International Nuclear Information System (INIS)

    Yao, Z.Y.; He, Q.; Qu, W.

    2002-01-01

    Purpose: Although there is considerable epidemiologic evidence for a relationship between plasma homocysteine (Hcy) levels and coronary artery disease (CAD), not all studies, especially prospective ones have shown such a relationship. The purpose of this study was to investigate a possible association between Hcy plasma levels and myocardial perfusion defect by SPECT in patients suspected CAD. Methods and Materials: A cohort of 238 patients suspected CAD (age: 60.65±10.43, male to female: 172: 66) was examined for Hcy, tetrahydrofolic acid (FH4), vitamine B12 and coronary angiography (CAG). Furthermore, 42 patients also underwent 99m Tc-MIBI myocardial perfusion images (MPI) to assess the myocardial perfusion. Results: There were 69 patients with normal CAG and 63, 60, 42 and 4 patients with 1 vessel, two vessel, 3 vessel and left main coronary stenosis. The plasma Hcy of this group was significantly increased, p 0.05. In patients with >=3 segments myocardial perfusion defect, 10 of them had normal Hcy, and 7 with hyperhomocysteinemia, in patients with 0.05). Conclusion: Our data may indicate that hyperhomocysteinemia represents an independent risk factor in patients with high possibility of CAD rather than a mark of myocardial ischemia or coronary stenosis

  3. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  4. Cardiac events in patients with positive exercise ECG and normal myocardial perfusion scan - a retrospective study

    International Nuclear Information System (INIS)

    Marshman, K.; Thomson, L.E.J.; Rowe, C.C.; Burns, A.J.; Woon, F.S.

    2002-01-01

    Full text: The low risk of future cardiac events following a normal myocardial perfusion study with normal stress ECG has been well documented. However, there is little literature regarding the prognosis in patients with a positive stress ECG (PosETT) and normal myocardial perfusion scan (MPS). A search of our database over an eighteen month period identified 21 patients who fitted study criteria. A PosETT was defined as stress induced horizontal or downsloping ST depression > 1mm in one or more leads with a normal baseline 12 lead ECG. Patients were divided into two subgroups depending on the severity of ST depression. A mildly PosETT was defined as ST depression of 1-1.5mm (n=10) and strongly PosETT was defined as ST depression of >2mm in at least one lead with depression in other leads (n=l 1). A normal MPS was defined as absence of reversible perfusion defects on SPECT imaging. Technetium 99m Tetrofosmin was the imaging agent used in 18/21 patients. All 21 patients exercised using the Bruce protocol for 3-12 minutes, and 9 experienced chest pain 12 months after the MPS, referring physicians were contacted. Cardiac events were defined as cardiac death, myocardial infarction, unstable angina, cardiac failure, revascularisation or a coronary angiogram demonstrating >70% stenosis. To date, follow up is complete in 11 patients with one confirmed case of single vessel revascularisation 3 months post MPS. Full follow up data will be presented. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Predictors of abnormal heart rate response to dipyridamole in patients undergoing myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    De Souza Leao Lima, R.; Machado, L.; Azevedo, A.B.; De Lorenzo, A.

    2011-01-01

    The objective of this study was to identify predictors of abnormal HR response to dipyridamole (DIP) in patients undergoing myocardial perfusion SPECT (MPS). Patients with a reduced heart rate (HR) response to DIP have higher cardiac mortality, but the mechanism is unknown. We studied 432 patients who underwent dual-isotope gated MPS. DIP (0.56 mg/kg) was infused over 4 min, and Tc-99m tetrofosmin was injected 3 min after the end of the infusion. MPS was semiquantitatively interpreted. Left ventricular ejection fraction (LVEF) and volumes were automatically calculated. The population was categorized into quartiles according to HR ratio, and characteristics in each quartile were compared. Logistic regression analysis was performed to identify predictors of abnormal HR response, using the lowest quartile as the independent variable. Patients with abnormal HR response were more frequently without chest pain, with a history of chronic renal failure and taking digoxin. Baseline HR was higher and had fewer symptoms during stress. The stress and rest perfusion defects were greater, but reversibility was not; in addition, LVEF was lower. Multivariable logistic regression analysis demonstrated that the independent predictors of abnormal HR response were baseline HR and low LVEF. LV dysfunction is an independent predictor of abnormal HR response to DIP, and the association between low LVEF and low HR ratio may explain the link between abnormal HR ratio and increased mortality. (author)

  6. Prospective assessment of regional myocardial perfusion before and after coronary revascularization surgery by quantitative thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.; Taylor, G.J.; Crosby, I.K.; Wellons, H.L.; Holt, N.D.; Beller, G.A.

    1983-01-01

    Because thallium-201 uptake relates directly to the amount of viable myocardium and nutrient blood flow, the potential for exercise scintigraphy to predict response to coronary revascularization surgery was investigated in 47 consecutive patients. All patients underwent thallium-201 scintigraphy and coronary angiography at a mean (+/- standard deviation) of 4.3 +/- 3.1 weeks before and 7.5 +/- 1.6 weeks after surgery. Thallium uptake and washout were computer-quantified and each of six segments was defined as normal, showing total or partial redistribution or a persistent defect. Persistent defects were further classified according to the percent reduction in regional thallium activity; PD25-50 denoted a 25 to 50% constant reduction in relative thallium activity and PD greater than 50 denoted a greater than 50% reduction. Of 82 segments with total redistribution before surgery, 76 (93%) showed normal thallium uptake and washout postoperatively, versus only 16 (73%) of 22 with partial redistribution (probability [p] . 0.01). Preoperative ventriculography revealed that 95% of the segments with total redistribution had preserved wall motion, versus only 74% of those with partial redistribution (p . 0.01). Of 42 persistent defects thought to represent myocardial scar before surgery, 19 (45%) demonstrated normal perfusion postoperatively. Of the persistent defects that showed improved thallium perfusion postoperatively, 75% had normal or hypokinetic wall motion before surgery, versus only 14% of those without improvement (p less than 0.001). Whereas 57% of the persistent defects that showed a 25 to 50% decrease in myocardial activity demonstrated normal thallium uptake and washout postoperatively, only 21% of the persistent defects with a decrease in myocardial activity greater than 50% demonstrated improved perfusion after surgery (p . 0.02)

  7. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism—Influence of window settings on the diagnosis of underlying pathologies of perfusion defects

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Kerl, J. Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.

    2011-01-01

    Purpose: On lung perfusion analysis with dual energy CT (DECT) in patients with suspected pulmonary embolism (PE) commonly three patterns of perfusion defects (PD) are observed: wedge-shaped, circumscribed but not wedge-shaped, and patchy. We investigated the influence of different window settings on the identification of the underlying pathologies for these types of PD. Materials and methods: 3724 segments in 196 consecutive patients who underwent pulmonary DECT angiography for clinically suspected acute PE were analyzed. Iodine distribution in the lung parenchyma was calculated from the dual energy data and displayed as color map in axial, sagittal and coronal view. Afterwards, lung and angiography window were applied separately and assessed for pulmonary embolism and pathologies of the lung parenchyma. Results: 1420 segments in 141 patients showed PD, of which 276 were wedge-shaped, 287 circumscribed and 857 patchy. Circumscribed PD were associated in 99% with interstitial or alveolar fluid collections and in 1% with located bullae. Patchy PD were associated in 65% with emphysematous or fibrotic changes, in 38% with diffuse infiltrations or interstitial fluid collections and in 0.2% with PE. The underlying pathologies for wedge-shaped PD were in 78% PE, in 3% tumors compressing pulmonary arteries, in another 3% located bullae and in further 3% infiltrations. 13% (n = 15) of the segments in this group did not show vascular or parenchymal pathologies, but in 80% (n = 10) of these cases patients had PE in another segment. Totally n = 6 of wedge-shaped PD in 5 patients remained with unclear direct cause. Conclusion: Whereas patchy and circumscribed PD are almost exclusively associated with pathologies of the lung parenchyma, wedge-shaped PD are mostly associated with PE. For a small number of wedge-shaped PD the underlying cause cannot be detected with DECT. Very small peripherally situated micro-emboli may be discussed as a reason. However, prospective trials are

  8. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  9. Exercise thallium-201 scintigraphy in men with nondiagnostic exercise electrocardiograms. Prognostic implications

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane-Marsch, S.

    1986-01-01

    We studied the prognostic value of exercise thallium-201 imaging in 196 men with suspected or known coronary artery disease who had nondiagnostic exercise electrocardiograms. The perfusion images in each of three projections were divided into three segments; each segment was assessed for perfusion defects (fixed or reversible). There were 12 cardiac events at a mean follow-up of 15 months (range, one to 66 months). Of those, five patients died of cardiac causes and seven had nonfatal acute myocardial infarctions (MIs). Only the number of perfusion defects significantly predicted cardiac events; clinical presentation, history of MI, presence of Q-wave MI, exercise duration, and exercise heart rate and double product did not predict cardiac events or add to information provided by the number of defects. Furthermore, actuarial life-table analysis showed that patients with three or more perfusion defects had significantly worse prognoses than patients with fewer than three defects. Exercise thallium-201 imaging helps in risk stratification of men with nondiagnostic exercise electrocardiograms

  10. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  11. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  12. Channelized relevance vector machine as a numerical observer for cardiac perfusion defect detection task

    Science.gov (United States)

    Kalayeh, Mahdi M.; Marin, Thibault; Pretorius, P. Hendrik; Wernick, Miles N.; Yang, Yongyi; Brankov, Jovan G.

    2011-03-01

    In this paper, we present a numerical observer for image quality assessment, aiming to predict human observer accuracy in a cardiac perfusion defect detection task for single-photon emission computed tomography (SPECT). In medical imaging, image quality should be assessed by evaluating the human observer accuracy for a specific diagnostic task. This approach is known as task-based assessment. Such evaluations are important for optimizing and testing imaging devices and algorithms. Unfortunately, human observer studies with expert readers are costly and time-demanding. To address this problem, numerical observers have been developed as a surrogate for human readers to predict human diagnostic performance. The channelized Hotelling observer (CHO) with internal noise model has been found to predict human performance well in some situations, but does not always generalize well to unseen data. We have argued in the past that finding a model to predict human observers could be viewed as a machine learning problem. Following this approach, in this paper we propose a channelized relevance vector machine (CRVM) to predict human diagnostic scores in a detection task. We have previously used channelized support vector machines (CSVM) to predict human scores and have shown that this approach offers better and more robust predictions than the classical CHO method. The comparison of the proposed CRVM with our previously introduced CSVM method suggests that CRVM can achieve similar generalization accuracy, while dramatically reducing model complexity and computation time.

  13. Creation of a Bioengineered Skin Flap Scaffold with a Perfusable Vascular Pedicle.

    Science.gov (United States)

    Jank, Bernhard J; Goverman, Jeremy; Guyette, Jacques P; Charest, Jon M; Randolph, Mark; Gaudette, Glenn R; Gershlak, Joshua R; Purschke, Martin; Javorsky, Emilia; Nazarian, Rosalynn M; Leonard, David A; Cetrulo, Curtis L; Austen, William G; Ott, Harald C

    2017-07-01

    Full-thickness skin loss is a challenging problem due to limited reconstructive options, demanding 75 million surgical procedures annually in the United States. Autologous skin grafting is the gold standard treatment, but results in donor-site morbidity and poor aesthetics. Numerous skin substitutes are available on the market to date, however, none truly functions as full-thickness skin due to lack of a vascular network. The creation of an autologous full-thickness skin analogue with a vascular pedicle would result in a paradigm shift in the management of wounds and in reconstruction of full-thickness skin defects. To create a clinically relevant foundation, we generated an acellular skin flap scaffold (SFS) with a perfusable vascular pedicle of clinically relevant size by perfusion decellularization of porcine fasciocutaneous flaps. We then analyzed the yielded SFS for mechanical properties, biocompatibility, and regenerative potential in vitro and in vivo. Furthermore, we assessed the immunological response using an in vivo model. Finally, we recellularized the vascular compartment of an SFS and reconnected it to a recipient's blood supply to test for perfusability. Perfusion decellularization removed all cellular components with preservation of native extracellular matrix composition and architecture. Biaxial testing revealed preserved mechanical properties. Immunologic response and biocompatibility assessed via implantation and compared with native xenogenic skin and commercially available dermal substitutes revealed rapid neovascularization and complete tissue integration. Composition of infiltrating immune cells showed no evidence of allorejection and resembled the inflammatory phase of wound healing. Implantation into full-thickness skin defects demonstrated good tissue integration and skin regeneration without cicatrization. We have developed a protocol for the generation of an SFS of clinically relevant size, containing a vascular pedicle, which can be

  14. The expression of myocardial injury in cold induced myocardial imaging and echocardiography of systematic scleroderma

    International Nuclear Information System (INIS)

    Liang Jiugen; Zhu Xiaojun; Jiang Ningyi; Chen Shaoxiong

    1999-01-01

    The study was performed with cold-induced 99m Tc(MIBI) myocardial imaging (MI) in 23 patients with systematic scleroderma. The left ventricular function and wall motion were also observed by dimensional echocardiography (UCG). 14 patients had myocardial perfusion abnormalities visualized by MI, including 5 cases with fixed defects of 9 segments, 3 cases with reversible defects of 6 segments and 6 cases with both fixed and reversible one of 14 segments. The positive rate in myocardial imaging had no significant differences between patients with and without Raynaud's phenomenon (0.5>P>0.25). Compared with baseline, the ejection fraction, stroke volume, cardiac output were significantly decreased during cold-induced in patients with abnormal myocardial scintigraphy (P<0.05), and had significant difference compared with normal group (P<0.05). 4 cases with cold-induced reversible perfusion defects had anatomically correlated regional ventricular hypokinesia in UCG

  15. The use of radioisotope techniques for the diagnosis of obstructive airway disease

    International Nuclear Information System (INIS)

    Furudate, Masatsugu; Itoh, Kazuo; Shida, Akira; Minami, Yukisato

    1981-01-01

    Perfusion scintigraphy, radioaerosol inhalation scintigraphy, 133 Xe studies and sup(81m)Kr studies are useful radioisotope techniques for the detection of regional pulmonary abnormalities in obstructive airway disease. The patient during asthmatic attack shows the perfusion defects with indefinite boundary, which may change during the following several days. Decreased ventilation are seen on the regions with perfusion defects, and ventilatory defects are more marked than those of perfusion. On the other hand, these abnomal findings is reversible. In chronic emphysema or chronic bronchitis, the regions with decreased perfusion usually cannot be correlated with any specific segments, and scintigraphys done repeatedly fail to show re-vascularization on the regions. In the radioaerosol inhalation scintigraphy, deposition pattern reveal the severity of COPD. In addition, xenon studies in the diseases show marked or moderate prolongation of wash-out from the abnormal region, and the abnormalities of ventilation are equal to or exceed the abnormalities of perfusion. (author)

  16. Use of radioisotope techniques for the diagnosis of obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Furudate, M; Itoh, K; Shida, A; Minami, Y [Hokkaido Univ., Sapporo (Japan). School of Medicine

    1981-07-01

    Perfusion scintigraphy, radioaerosol inhalation scintigraphy, /sup 133/Xe studies and sup(81m)Kr studies are useful radioisotope techniques for the detection of regional pulmonary abnormalities in obstructive airway disease. The patient during asthmatic attack shows the perfusion defects with indefinite boundary, which may change during the following several days. Decreased ventilation are seen on the regions with perfusion defects, and ventilatory defects are more marked than those of perfusion. On the other hand, these abnomal findings are reversible. In chronic emphysema or chronic bronchitis, the regions with decreased perfusion usually cannot be correlated with any specific segments, and scintigraphys done repeatedly fail to show re-vascularization on the regions. In the radioaerosol inhalation scintigraphy, deposition pattern reveal the severity of COPD. In addition, xenon studies in the diseases show marked or moderate prolongation of wash-out from the abnormal region, and the abnormalities of ventilation are equal to or exceed the abnormalities of perfusion.

  17. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  18. Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: rationale and design of a prospective, randomized, multicenter study.

    Science.gov (United States)

    Tejani, Furqan H; Thompson, Randall C; Iskandrian, Ami E; McNutt, Bruce E; Franks, Billy

    2011-02-01

    Caffeine attenuates the coronary hyperemic response to adenosine by competitive A₂(A) receptor blockade. This study aims to determine whether oral caffeine administration compromises diagnostic accuracy in patients undergoing vasodilator stress myocardial perfusion imaging (MPI) with regadenoson, a selective adenosine A(2A) agonist. This multicenter, randomized, double-blind, placebo-controlled, parallel-group study includes patients with suspected coronary artery disease who regularly consume caffeine. Each participant undergoes three SPECT MPI studies: a rest study on day 1 (MPI-1); a regadenoson stress study on day 3 (MPI-2), and a regadenoson stress study on day 5 with double-blind administration of oral caffeine 200 or 400 mg or placebo capsules (MPI-3; n = 90 per arm). Only participants with ≥ 1 reversible defect on the second MPI study undergo the subsequent stress MPI test. The primary endpoint is the difference in the number of reversible defects on the two stress tests using a 17-segment model. Pharmacokinetic/pharmacodynamic analyses will evaluate the effect of caffeine on the regadenoson exposure-response relationship. Safety will also be assessed. The results of this study will show whether the consumption of caffeine equivalent to 2-4 cups of coffee prior to an MPI study with regadenoson affects the diagnostic validity of stress testing (ClinicalTrials.gov number, NCT00826280).

  19. Tc-99m macroaggregate albumin perfusion studies in the therapeutically embolized liver

    International Nuclear Information System (INIS)

    Hall, J.T.; Kim, E.E.; Charnsangavej, C.; Haynie, T.P.; Wallace, S.

    1988-01-01

    This paper discusses the authors' study of 15 patients who underwent 21 hepatic arterial chemoembolizations and hepatic arterial chemotherapy infusions. The arteriograms and the hepatic perfusion studies using Tc-99m macroaggregates of human serum albumin (MAA) particles were reviewed and correlated. Early perfusion studies (within 4 hours of embolization) often revealed flow reversal or MAA reflux into an undesirable location. Scans obtained at 24 hours revealed restoration of flow to the embolized lobe, confirming the proper position of the catheter for hepatic arterial chemotherapy infusion

  20. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  1. Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A. [Wesley Research Inst., The Wesley Hospital, Brisbane (Australia); Brighton and Sussex Medical School, Univ. of Sussex, Falmer, Brighton (United Kingdom)

    2003-12-01

    Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and blood attenuation during a rapid series of images acquired without table movement following an intravenous bolus of contrast medium to generate images of mean transit time (MTT) cerebral blood volume (CBV) and perfusion. Reduced perfusion with preserved CBV is indicative of reversible ischaemia, whereas a matched reduction in perfusion and CBV implies infarction. The CT perfusion imaging can positively identify patients with non-haemorrhagic stroke in the presence of a normal conventional CT, provide an indication as to prognosis and potentially select those patients for whom thrombolysis is appropriate. Perfusion CT offers a powerful adjunct to MDCT based imaging of cerebrovascular disease, but further clinical validation is required. (orig.)

  2. Assessment of myocardial perfusion and metabolism for assessment of myocardial viability

    International Nuclear Information System (INIS)

    Beller, G.

    1996-01-01

    Identifying preserved myocardial viability in the presence of severe regional left ventricular dysfunction is becoming increasingly more important for clinical decision-making to better select those patients with coronary artery disease who will benefit most from revascularization. 201 Tl remains the most commonly employed radionuclide for detecting both ischemia and viability. A severe persistent defect with 201 Tl uptake compared to peak to improved perfusion and corresponding improved function after revascularisation. Detection of defect reversibility on 201 Tl imaging is enhanced by 'reinjection' of a second 201 Tl dose after acquisition of redistribution images. Initial and 4-hour rest/redistribution imaging has proven most usefull for detection of viability in the resting state in patients with ischemic cardiomyopathy. The greater the extent of preoperative viability, the greater is the improvement in regional and global function after revascularisation. 99 Tc sestamibi has also been demonstrated to be extracted by myocardial cells in proportion to regional blood flow in the presence of viable myocities. Although this agrnt does not redistribute after intravenous injection, its >50% uptake of the tracer implies viablility and predicts improved regional function after revascularisation. Finally positron emission tomography with 18 F fluorodeoxoglucose (FDG) is perhaps the most sensitive noninvasive imaging technique for detection of viability in stunned or hibernating myocardium. A mismatch pattern between regional flow and FDG uptake as approximately an 80-85% positive preicted value for predicting improved function in asynergic myocardial regions after revascualarisation

  3. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  4. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal d...... defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality....

  5. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results

    International Nuclear Information System (INIS)

    Garcia C, S.E.; Garcia O, R.

    2005-01-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  6. Reevaluation of lung perfusion scintigrams with 99mTc-macroaggregated albumin (Tc-MAA) as a tool of diagnostic procedures of chronic pulmonary emphysema

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Maruyama, Masao; Takamoto, Masahiro; Tanaka, Yasushi; Harada, Susumu; Harada, Yasuko; Ishibashi, Tsuneo; Shinoda, Atsushi

    1991-01-01

    We performed scintiscanning with Tc-MAA lung perfusion in thirty cases of chronic pulmonary emphysema (CPE) and thirty cases of bronchial asthma. In the former group, all of the cases showed the definite emphysematous changes on computed tomography (CT). It seemed that the whole impression to scintigram could diagnose CPE almost correctly. As the most important abnormality in scintigrams of CPE was their filling defects, we examined the characteristics of the defect-lesions. The results were as follows: firstly, the main lesions extended to the lobar to half-lobar size; secondly, defects were multiple in general; and thirdly, the distribution of defects was diffuse. Whereas the lesion in the scintigram is nonspecific for diagnosis of CPE in contrast to CT, we conclude that perfusion scintigram is valuable to evaluate the severity of CPE. (author)

  7. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    International Nuclear Information System (INIS)

    Mathews, Marlon S.; Binder, Devin K.; Smith, Wade S.; Wintermark, Max; Dillon, William P.

    2008-01-01

    Postictal (''Todd's'') paralysis, or ''epileptic hemiplegia,'' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  8. Perfusion-induced changes in cardiac contractility depend on capillary perfusion.

    Science.gov (United States)

    Dijkman, M A; Heslinga, J W; Sipkema, P; Westerhof, N

    1998-02-01

    The perfusion-induced increase in cardiac contractility (Gregg phenomenon) is especially found in heart preparations that lack adequate coronary autoregulation and thus protection of changes in capillary pressure. We determined in the isolated perfused papillary muscle of the rat whether cardiac muscle contractility is related to capillary perfusion. Oxygen availability of this muscle is independent of internal perfusion, and perfusion may be varied or even stopped without loss of function. Muscles contracted isometrically at 27 degrees C (n = 7). During the control state stepwise increases in perfusion pressure resulted in all muscles in a significant increase in active tension. Muscle diameter always increased with increased perfusion pressure, but muscle segment length was unaffected. Capillary perfusion was then obstructed by plastic microspheres (15 microns). Flow, at a perfusion pressure of 66.6 +/- 26.2 cmH2O, reduced from 17.6 +/- 5.4 microliters/min in the control state to 3.2 +/- 1.3 microliters/min after microspheres. Active tension developed by the muscle in the unperfused condition before microspheres and after microspheres did not differ significantly (-12.8 +/- 29.4% change). After microspheres similar perfusion pressure steps as in control never resulted in an increase in active tension. Even at the two highest perfusion pressures (89.1 +/- 28.4 and 106.5 +/- 31.7 cmH2O) that were applied a significant decrease in active tension was found. We conclude that the Gregg phenomenon is related to capillary perfusion.

  9. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  10. Unusual ventilation perfusion scintigram in a case of immunologic pulmonary edema clinically simulating pulmonary embolism

    International Nuclear Information System (INIS)

    Campeau, R.J.; Faust, J.M.; Ahmad, S.

    1987-01-01

    A case of immunologic pulmonary edema secondary to hydrochlorothiazide allergy developed in a 55-year-old woman that clinically simulated pulmonary embolism. The patient had abnormal washin images with normal washout images on an Xe-133 ventilation study. On the perfusion study, large bilateral central and posterior perfusion defects were present that showed an unusual mirror image pattern on the lateral and posterior oblique views. Resolution of radiographic and scintigraphic abnormalities occurred over a 3-day period in conjunction with corticosteroid therapy

  11. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  12. Important parameters in the detection of left main trunk disease using stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Shiba, Chie; Chikamori, Taishiro; Hida, Satoshi

    2009-01-01

    We sought noninvasively to diagnose left main trunk (LMT) disease using myocardial perfusion imaging (MPI). Five hundred and eight patients with suspected coronary artery disease (CAD) underwent both stress MPI and coronary angiography. The extent and severity of perfusion abnormalities were assessed using a 20-segment model. In addition, perfusion defects in both left anterior descending and left circumflex arterial territories were defined as a left main (LM) pattern defect, and those in 3-coronary arterial territories as a 3-vessel pattern defect. In 42 patients with LMT disease, a summed stress score (19.4±10.0 vs. 13.5±10.0; p<0.0001) and a summed rest score (12.1±9.7 vs. 7.0±7.8; p=0.002) were greater than in 466 patients without LMT disease, while a summed difference score was similar (7.3±7.7 vs. 6.5±6.1; p=NS). The prevalence of an LM-pattern defect was low in both groups (12% vs. 8%; p=NS). However, a 3-vessel pattern defect (33% vs. 7%; p<0.0001), lung uptake of radiotracers (38% vs. 11%; p<0.0001), and transient ischemic dilation (31% vs. 13%; p=0.003) were more frequently observed in patients with LMT disease than in those without. Logistic regression analysis showed that a 3-vessel pattern defect (odds ratio (OR)=3.5, 95% confidence interval (CI)=1.4-8.8; p=0.007), lung uptake of radiotracers (OR=2.5, 95% CI=1.1-5.7; p=0.03), and previous myocardial infarction (MI) (OR=2.4, 95% CI=1.0-5.7; p=0.05) were the most important parameters to detect LMT disease. After excluding 163 patients with previous MI, a repeat analysis revealed that lung uptake of radiotracers (OR=8.2, 95% CI=2.3-29.2; p=0.001) and an LM-pattern defect (OR=6.3, 95% CI=1.4-27.2; p<0.02) were independent predictors for LMT disease. In the identification of LMT disease, lung uptake of radiotracers was a single best parameter, which was independent of the presence or absence of previous MI. (author)

  13. Application of myocardial perfusion quantitative imaging for the evaluation of therapeutic effect in canine with myocardial infarction

    International Nuclear Information System (INIS)

    Liang Hong; Chen Ju; Liu Sheng; Zeng Shiquan

    2000-01-01

    Myocardial blood perfusion (MBP) ECT and quantitative analysis were performed in 10 canines with experimental acute myocardial infarct (AMI). The accuracy of main myocardial quantitative index, including defect volume (DV) and defect fraction (DF), was estimated and correlated with histochemical staining (HS) of infarcted area. Other 21/AMI canines were divided into Nd:YAG laser trans-myocardial revascularization treated group LTMR and control group. All canines were performed MBP ECT after experimental AMI. Results found that the infarcted volume (IV) measured by HS has well correlated (r 0.88) with DV estimated by myocardial quantitative analysis. But the DF values calculated by both methods was not significantly different (t = 1.28 P > 0.05). In LTMR group 27.5% +- 3.9%, the DF is smaller than control group 32.1% +- 4.6% (t = 2.49 P 99m Tc-MIBI myocardial perfusion SPECT and quantitative study can accurately predict the myocardial blood flow and magnitude of injured myocardium. Nd:YAG LTMR could improve myocardial blood perfusion of ischemic myocardium and decrease effectively the infarct areas

  14. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, I.; Sonmez, B. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Nuclear Medicine; Sezen, O.; Zengin, A.Y.; Bahat, Z. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Radiation Oncology; Yenilmez, E.; Yulug, E. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Histology and Embryology; Abidin, I. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Biophysics

    2010-07-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ({sup 99m}Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  15. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    International Nuclear Information System (INIS)

    Dogan, I.; Sonmez, B.; Sezen, O.; Zengin, A.Y.; Bahat, Z.; Yenilmez, E.; Yulug, E.; Abidin, I.

    2010-01-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ( 99m Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  16. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    In SPECT imaging, collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. In this paper, we seek the collimator with the optimal tradeoff between image noise and resolution with respect to performance on two tasks related to myocardial perfusion SPECT: perfusion defect detection and joint detection and localization. We used the Ideal Observer (IO) operating on realistic background-known-statistically (BKS) and signal-known-exactly (SKE) data. The areas under the receiver operating characteristic (ROC) and localization ROC (LROC) curves (AUCd, AUCd+l), respectively, were used as the figures of merit for both tasks. We used a previously developed population of 54 phantoms based on the eXtended Cardiac Torso Phantom (XCAT) that included variations in gender, body size, heart size and subcutaneous adipose tissue level. For each phantom, organ uptakes were varied randomly based on distributions observed in patient data. We simulated perfusion defects at six different locations with extents and severities of 10% and 25%, respectively, which represented challenging but clinically relevant defects. The extent and severity are, respectively, the perfusion defect’s fraction of the myocardial volume and reduction of uptake relative to the normal myocardium. Projection data were generated using an analytical projector that modeled attenuation, scatter, and collimator-detector response effects, a 9% energy resolution at 140 keV, and a 4 mm full-width at half maximum (FWHM) intrinsic spatial resolution. We investigated a family of eight parallel-hole collimators that spanned a large range of sensitivity-resolution tradeoffs. For each collimator and defect location, the IO test statistics were computed using a Markov Chain Monte Carlo (MCMC) method for an ensemble of 540 pairs of defect-present and -absent images that included the aforementioned anatomical and uptake variability. Sets of test statistics were

  17. Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

    Science.gov (United States)

    He, Xin; Song, Xiyun; Frey, Eric C

    2008-11-01

    The diagnosis of cardiac disease using dual-isotope myocardial perfusion SPECT (MPS) is based on the defect status in both stress and rest images, and can be modeled as a three-class task of classifying patients as having no, reversible, or fixed perfusion defects. Simultaneous acquisition protocols for dual-isotope MPS imaging have gained much interest due to their advantages including perfect registration of the (201)Tl and (99m)Tc images in space and time, increased patient comfort, and higher clinical throughput. As a result of simultaneous acquisition, however, crosstalk contamination, where photons emitted by one isotope contribute to the image of the other isotope, degrades image quality. Minimizing the crosstalk is important in obtaining the best possible image quality. One way to minimize the crosstalk is to optimize the injected activity of the two isotopes by considering the three-class nature of the diagnostic problem. To effectively do so, we have previously developed a three-class receiver operating characteristic (ROC) analysis methodology that extends and unifies the decision theoretic, linear discriminant analysis, and psychophysical foundations of binary ROC analysis in a three-class paradigm. In this work, we applied the proposed three-class ROC methodology to the assessment of the image quality of simultaneous dual-isotope MPS imaging techniques and the determination of the optimal injected activity combination. In addition to this application, the rapid development of diagnostic imaging techniques has produced an increasing number of clinical diagnostic tasks that involve not only disease detection, but also disease characterization and are thus multiclass tasks. This paper provides a practical example of the application of the proposed three-class ROC analysis methodology to medical problems.

  18. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  19. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    International Nuclear Information System (INIS)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio; Takeuchi, Yoshihito.

    1998-01-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  20. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio [Aichi Cancer Center, Nagoya (Japan); Takeuchi, Yoshihito

    1998-02-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  1. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  2. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    International Nuclear Information System (INIS)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J.; Higashigaito, Kai; Jung, Andreas

    2018-01-01

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  3. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J. [University Children' s Hospital Zuerich, Department of Diagnostic Imaging, Zuerich, CH (Switzerland); University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); Higashigaito, Kai [University Hospital Zuerich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Jung, Andreas [University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); University Children' s Hospital Zuerich, Division of Pneumology, Zuerich (Switzerland)

    2018-02-15

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  4. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan [Changzheng Hospital of the Second Military Medical University, Department of Radiology, Shanghai (China); Zhang, Tie-feng; Li, Bing [Changzheng Hospital of the Second Military Medical University, Department of Respiration Medicine, Shanghai (China)

    2013-05-15

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R{sub SI}) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R{sub SI,} MSI, PEI and MSD. Differences were found in R{sub SI} between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  5. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    International Nuclear Information System (INIS)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan; Zhang, Tie-feng; Li, Bing

    2013-01-01

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R SI ) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R SI, MSI, PEI and MSD. Differences were found in R SI between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  6. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  7. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  8. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    Science.gov (United States)

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  9. The value of regional wall motion abnormalities on gated mycardiac perfusion imaging in perfusion imaging in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Yao Lixin; Liu Binbin

    2007-01-01

    Objective: To determine the possible level of angiographic stenoses of coronary artery at which reversible regional wall motion abnormalities (RWMA) are present on 99m Tc-sestamibi ( 99m Tc-MIBI)-gated myocardial perfusion imaging (MPI). Methods: ninty patients undergoing coronary angiography MPI within two weeks were recruited. A five grades and nine segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 64%,with a specificity of 95% and positive predictive value of 97%. The presence of reversible RWMA was able to stratify patients with severe angiographic stenoses of 75% or more from those less than 75% with high positive predictive value. A good correlation was noted between the presence of reversible RWMA and the coronary artery jeopardy score. Multivariate analysis showed that the post-stress RWMA and reversible RWMA scores and positive dipyridamole-stress exercise electrocardiogram(ECG) were significant predictors of angiographic severity. Conclusions: Reversible RWMA, as shown by dipyridamole stress 99m Tc-MIBI MPI, is a significant predictor of angiographic disease with very high specificity and adds incremental value to MPI for the assessment of angiographic severity. (authors)

  10. The effect of captopril on thallium 201 myocardial perfusion in systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.; Menkes, C.J.; Weber, S.; Venot, A.; Strauch, G.

    1990-01-01

    In systemic sclerosis, abnormalities of myocardial perfusion are common and may be caused by a disturbance of the coronary microcirculation. We evaluated the long-term effect of captopril (75 to 150 mg per day) on thallium 201 myocardial perfusion in 12 normotensive patients with systemic sclerosis. Captopril significantly decreased the mean (+/- SD) number of segments with thallium 201 myocardial perfusion defects (6.5 +/- 1.9 at baseline and 4.4 +/- 2.7 after 1 year of treatment with captopril; p less than 0.02) and increased the mean global thallium score (9.6 +/- 1.7 at baseline and 11.4 +/- 2.1 after captopril; p less than 0.05). In a control group of eight normotensive patients with systemic sclerosis who did not receive captopril, no significant modification in thallium results occurred. Side effects with captopril included hypotension (six patients), taste disturbances (one patient), and skin rash (one patient). These side effects subsided when the dosage was reduced. These findings demonstrate that captopril improves thallium 201 myocardial perfusion in patients with systemic sclerosis and may therefore have a beneficial effect on scleroderma myocardial disease

  11. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. POSTEROLATERAL DEFECT OF THE NORMAL HUMAN HEART INVESTIGATED WITH NITROGEN-13-AMMONIA AND DYNAMIC PET

    NARCIS (Netherlands)

    DEJONG, RM; BLANKSMA, PK; WILLEMSEN, ATM; ANTHONIO, RL; MEEDER, JG; PRUIM, J; VAALBURG, W; LIE, KI

    The posterolateral defect is a common artifact seen when static N-13-ammonia imaging with PET is used to assess myocardial perfusion. The aim of this study was to compare dynamic and static N-13-ammonia PET and to obtain more insight into the cause of the posterolateral defect. Methods: Dynamic

  13. Quantitative myocardial perfusion PET parametric imaging at the voxel-level

    International Nuclear Information System (INIS)

    Mohy-ud-Din, Hassan; Rahmim, Arman; Lodge, Martin A

    2015-01-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82 Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves. (paper)

  14. Effects of isoproterenol on distribution of perfusion in embolized dog lungs

    International Nuclear Information System (INIS)

    Shepard, J.W. Jr.; Hauer, D.; Sgroi, V.; Moser, K.M.

    1979-01-01

    In 19 mechanically ventilated, anesthetized dogs, autologous venous thrombi were formed in the inferior vena cava and subsequently released. Serial perfusion lung scintigrams revealed the postembolic distribution of pulmonary blood flow before, during, and after the infusion of isoproterenol at 2.2 μg/min. Isoproterenol failed to restore perfusion to embolically occluded regions. When reperfusion occurred it was attributable to clot resolution. Gas exchange and hemodynamic measurements obtained in seven thromboembolized animals showed no scan evidence of reperfusion during the isoproterenol infusion. After embolization, cardiac output increased from 1.7 to 2.6 liter/min (p 2 from 38.0 to 45.3 mm Hg (p 2 to 50.7 mm Hg, along with a decrease in pulmonary vascular resistance from the postembolic mean of 448 to 246 dynes.sec.cm -5 (p < 0.05). Perfusion defects following acute pulmonary thromboembolization are not altered by the infusion of the potent pulmonary vasodilator, isoproterenol. Infusion of this drug following thromboembolization may have potential therapeutic benefit by reducing pulmonary vascular resistance, increasing cardiac output, and elevating the mixed-venous oxygen tension

  15. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET

    International Nuclear Information System (INIS)

    Yoshinaga, Keiichiro; Tamaki, Nagara; Katoh, Chietsugu; Kuge, Yuji; Noriyasu, Kazuyuki; Yamada, Satoshi; Ito, Yoshinori; Kohya, Tetsuro; Kitabatake, Akira; Kawai, Yuko

    2002-01-01

    The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67±7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake ≥50%) was employed as the gold standard. One-day stress-rest 99m Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 μg kg -1 min -1 of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments (P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress

  17. Phosphorus NMR of isolated perfused morris hepatomas

    International Nuclear Information System (INIS)

    Graham, R.A.; Meyer, R.A.; Brown, T.R.; Sauer, L.A.

    1986-01-01

    The authors are developing techniques for the study of perfused solid tumors by NMR. Tissue-isolated solid hepatomas were grown to 1-2 cm diameter as described previously. The arterial supply was isolated and the tumors perfused (0.5 - 1.0 ml/min) in vitro at 25 C with a 15% suspension of red blood cells in Krebs-Henseliet solution. 31 P-NMR spectra were acquired at 162 MHz in a specially-designed NMR probe using a solenoidal coil. Intracellular pH (monitored from the chemical shift of inorganic phosphate) and ATP levels were stable for up to 6 hrs during perfusion. During 30 min of global ischemia, ATP decreased by 75% and pH fell from 7.0 to 6.7. These changes were reversed by 1 hr reperfusion. In addition to ATP and phosphate, the spectra included a large resonance due to phosphomonoesters, as well as peaks consistent with glycerylphosphocholine, glyceryl-phosphoethanolamine, phosphocreatine, NAD, and UDPG. However, the most novel feature of the spectra was the presence of an unidentified peak in the phosphonate region (+ 16.9 ppm). The peak was not present in spectra of muscle, liver, brain, kidney, or fat tissues excised from the same animals. They are presently attempting to identify the compound that gives rise to this peak and to establish its metabolic origin

  18. Evaluation of cerebral perfusion imaging with N-isopropyl-p-[123I]iodoamphetamine (IMP) in the cases of antiphospholipid syndrome

    International Nuclear Information System (INIS)

    Kato, Toru; Nanbu, Ichiro; Tohyama, Junko; Ohba, Satoru

    1995-01-01

    Five cases of antiphospholipid syndrome with mild headache, but without any neurological deficits and abnormal findings by CT and MRI, were examined by cerebral blood perfusion SPECT using N-isopropyl-p-[ 123 I] iodoamphetamine (IMP). Although three cases were performed quantification of cerebral blood flow with a microsphere method simultaneously, their values were within normal limits. Two of them showed focal low perfusion areas. One case had relatively low perfusion areas in the bilateral occipital lobes and the right temporal lobe, which improved after treatment. One of two had low perfusion in the bilateral occipital lobes. Other three cases only showed ununiformity of radioisotope uptake on the cerebral blood perfusion SPECT. Low perfusion areas in antiphospholipid syndrome might be caused by microarterial thrombosis, microvenous thrombosis or spasms, although they could be reversible. As early irreversible progress of cerebral blood flow, cerebral blood flow SPECT should be performed in cases of antiphospholipid syndrome with neurological complainments. (author)

  19. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  20. Collateral Function in Patients with Coronary Occlusion Evaluated by 201Thallium Scintigraphy

    Directory of Open Access Journals (Sweden)

    Aida Hasanović

    2008-11-01

    Full Text Available The present study evaluated the impact of the angiographically documented collaterals on regional myocardial perfusion measured by 201thallium scintigraphy in patients with a chronic total occlusion.The study included 60 patients with chronic total occlusion who underwent rest-stress myocardial perfusion scintigraphy and coronary angiography. All patients had angiographic evidence of coronary collaterals. Patients were divided into two groups: group one had well-developed coronary collateral vessels (n=35 and group II had poor coronary collateral development (n=25.Patients with chronic total occlusion had severe and extensive stress-induced myocardial perfusion defects regardless of the grade of angiographic coronary collaterals. The perfusion defects in the group with good collaterals were predominantly reversible, suggesting that coronary collaterals preserved myocardial viability in the regions subtended by a total coronary occlusion. A significant correlation between good collaterals with complete protection and poor collaterals with no protection was noted.Our results demonstrate a protective effect of collaterals on myocardial perfusion during coronary occlusion. The effective angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defect.

  1. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, Marlon S.; Binder, Devin K. [University of California, Department of Neurological Surgery, Irvine, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Wintermark, Max; Dillon, William P. [University of California, Department of Radiology, San Francisco, CA (United States)

    2008-05-15

    Postictal ('Todd's') paralysis, or 'epileptic hemiplegia,' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  2. Herpes simplex encephalitis: increased retention of Tc-99m HMPAO on acetazolamide enhanced brain perfusion SPECT

    International Nuclear Information System (INIS)

    Choi, Yun Young; Kim, Kwon Hyung; Kim, Seung Hyun; Cho, Suk Shin

    1998-01-01

    We present an interesting case of herpes simplex encephalitis, which showed increased upta unilateral temporal cortex on brain perfusion SPECT using Tc-99m HMPAO, but in bilateral tem cortex after acetazolamide administration. A 42-year-old man was admitted via emergency room, due to rapidly progressing hea disorientation and mental changes. On neurologic examination, neck stiffness and Kernig sign noted. CSF examination showed pleocytosis with lymphcyte predominance. MRI showed swelling bilateral temporal lobe with left predominance, suggestive of herpes simplex encephalitis. Baseline/ Acetazolamide brain perfusion SPECT were acquired consecutively at the same position IV administration of 740MBq and additional 1480 MBq of Tc-99m HMPAO respectively. The temporal and inferior frontal cortex showed markedly increased perfusion on the baseline acetazolamide-enhanced SPECT images. The right temporal cortex showed normal uptake on the b SPECT images, and markedly increased uptake after acetazolamide administration, which seemed to the abundant vascularity at the acute inflammation site without marked brain damage. The fo brain perfusion SPECT after 6 months showed perfusion defect in left temporal cortex but norm perfusion in right temporal cortex. Therefore, we can conclude that baseline SPECT is helpful for the prediction of the prognosis acetazolamide SPECT for the evaluation of the extent of herpes simples encephalitis

  3. Value of myocardial perfusion SPECT in pediatric population

    International Nuclear Information System (INIS)

    Massardo, T.; Coll, C.; Prat, H.; Gonzalez, P.; Doggenweiller, P.; Castillo, M.E.; Solis, A.

    2002-01-01

    Isotopic myocardial perfusion studies are less frequently used in children than in adults and their indications are also different. Our goal was to analyze retrospectively the experience with stress perfusion myocardial SPECT in pediatric population. Method: Since 1998 to 2001, ten studies were performed to 5 girls and 3 boys. Their mean age was 7±3 years ranging from 1-11. Three of them presented abnormal coronary arteries pre and post surgical intervention with or without coil; three had Kawasaki disease with coronary aneurysms and the other two, congenital cardiopathies (Cantrell pentalogy and great vessel transposition,both with posterior left ventricular hypokinesia post surgery). Stress was obtained using dipyridamole infusion (0.56 mg/kg) in 6 cases and treadmill exercise using Bruce protocol in 4. All those tests were well tolerated. Sestamibi Tc99m was selected in 80% of the cases and Tl 201 in the rest. Only 2 small children required anesthesia during SPECT acquisition. Results: Stress EKG did not demonstrated ischemia in any case. Coronary angiography was performed only in 50% of the patients, it was concordant with SPECT features in all, two of those patients presented transient perfusion defects (one Kawasaki and one abnormal coronary artery with a fistulae).The repaired pentalogy presented ischemia and septal infarction; in that patient echocardiographic hipokinesia was concordant with fixed hypoperfusion. One case with abnormal coronary plus mitral regurgitation (without isotopic ischemia) was submitted to embolization posteriorly, obtaining motion improvement. Clinical outcome was concordant with the presence or absence of isotopic ischemia in the rest of the patients. Conclusion: SPECT myocardial perfusion was helpful in the therapeutic approach and in prediction of outcome in children

  4. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Keiichiro; Miyamae, Tatsuya

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful. (author)

  5. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients

    Energy Technology Data Exchange (ETDEWEB)

    Le Faivre, Julien; Khung, Suonita; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Duhamel, Alain [University of Lille, Department of Biostatistics, Lille (France); Lamblin, Nicolas [University of Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2016-11-15

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. (orig.)

  6. Myocardial SPECT in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Hallaj, I.; Barritault, L.; Acar, P.; Montalembert, M. de

    2002-01-01

    Aim: While cerebral and bones strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Conventional techniques such as exercise testing and echocardiography have a low sensitivity and specificity to detect myocardial ischemia in patients with SCD. The aim of this prospective study was to assess myocardial perfusion with 201 Tl SPECT in children with SCD. Materials and Methods: Twenty-two patients, aged 12 ± 4 years, were included. Myocardial perfusion was assessed by 201 Tl SPECT after stress and 3 hours later after reinjection on a single head gammacamera equipped with a LEAP collimator (64x64 matrix size format, 30 projections over 180 0 , 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Results: Myocardial perfusion was impaired in 13/22 patients: 8 had reversible defects and 5 had fixed defects. The left ventricular cavity was dilated in 13/22 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. Conclusion: Myocardial perfusion is frequently impaired in children with SCD. Treatment with hydroxyurea should be considered in SCD patients with perfusion defects

  7. Vasodilator stress impairs the left ventricular function obtained with gated single-photon emission computed tomography in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Odagiri, Keiichi; Uehara, Akihiko; Kurata, Chinori

    2010-01-01

    Transient ischemic dilatation (TID) and post-stress dysfunction of the left ventricle (LV) are important markers of severe coronary artery disease (CAD). To clarify the effects of stressor type on TID and post-stress LV dysfunction, changes in LV measurements were compared between patients with exercise- or vasodilator-induced stress. The 689 patients referred for technetium-99m tetrofosmin myocardial perfusion imaging were included. Patients were stressed with either a vasodilator (n=236) or exercise (n=453). LV measurements were obtained with electrocardiogram (ECG)-gated single photon emission computed tomography (SPECT). LV end-diastolic and end-systolic volume indexes (LVEDVI, LVESVI) increased and LV ejection fraction (LVEF) decreased after stress in the vasodilator-stress group. Vasodilator-stress and the summed difference score (SDS) were independent variables that decreased LVEF after stress. Even in patients without reversible defects, vasodilator-stress impaired LV function. There were no differences in the stress-to-rest ratios of LVEDVI (rEDV) and LVESVI (rESV) among patients with normal myocardial perfusion, fixed defects and reversible defects in the vasodilator-stress group, whereas in the exercise-stress group, rESV was significantly higher in the patients with reversible defects than in those without reversible defects. Within the vasodilator-stress group, neither rEDV nor rESV correlated with the SDS. Vasodilator-stress by itself decreases LVEF after stress. TID should be carefully interpreted when vasodilator-stress is used to detect severe CAD. (author)

  8. Evaluation of cerebral perfusion imaging with N-isopropyl-p-[{sup 123}I]iodoamphetamine (IMP) in the cases of antiphospholipid syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Toru; Nanbu, Ichiro; Tohyama, Junko; Ohba, Satoru [Nagoya City Univ. (Japan). Faculty of Medicine

    1995-01-01

    Five cases of antiphospholipid syndrome with mild headache, but without any neurological deficits and abnormal findings by CT and MRI, were examined by cerebral blood perfusion SPECT using N-isopropyl-p-[{sup 123}I] iodoamphetamine (IMP). Although three cases were performed quantification of cerebral blood flow with a microsphere method simultaneously, their values were within normal limits. Two of them showed focal low perfusion areas. One case had relatively low perfusion areas in the bilateral occipital lobes and the right temporal lobe, which improved after treatment. One of two had low perfusion in the bilateral occipital lobes. Other three cases only showed ununiformity of radioisotope uptake on the cerebral blood perfusion SPECT. Low perfusion areas in antiphospholipid syndrome might be caused by microarterial thrombosis, microvenous thrombosis or spasms, although they could be reversible. As early irreversible progress of cerebral blood flow, cerebral blood flow SPECT should be performed in cases of antiphospholipid syndrome with neurological complainments. (author).

  9. Role of redistribution and 24 hour reinjection images to assess myocardial viability in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yoon, Seok Nam; Pai, Moon Sun; Park, Chan H.; Yoon, Myung Ho; Choi, Byung Il

    1998-01-01

    We evaluated the importance of redistribution and 24 hour reinjection images in Tl-201 SPECT assessment of myocardial viability after acute myocardial infarction (AMI). We performed dipyridamole stress-4 hour redistribution-24 hour reinjection Tl-201 SPECT in 43 patients with recent AMI (4-16 days). The myocardium was divided into 16 segments and perfusion grade was measured visually with 4 point score from 0 to 3 (absent uptake to normal uptake). A perfusion defect with stress score 2 was considered moderate. A defect was considered severe if the stress score was 0 or 1 (absent uptake or severe perfusion decrease). Moderate defect on stress image were considered viable and and segments with severe defect were considered viable if they showed improvement of 1 score or more on redistribution or reinjection images. We compared the results of viability assessment in stress-redistribution and stress-reinjection images. On visual analysis, 344 of 688 segments (50%) had abnormal perfusion. Fify two (15%) had moderate perfusion defects and 292 (85%) had severe perfusion defects on stress image. Of 292 severe stress defects, 53 were irreversible on redistribution and reversible on reinjection images, and 15 were reverseble on redistribution and irreversible on reinjection images. Two hundred twenty four of 292 segments (76.7%) showed concordant results on stress-redistribution and stress- reinjection images. Therefore 24 hour reinjection image changed viability status from necrotic to viable in 53 segments of 292 severe stress defect (18%). However, myocardial viability was underestimated in only 5% (15/292) of severe defects by 24 hour reinjection. The 24 hour reinjection imaging is useful in the assessment of myocardial viability. It is more sensitive than 4 hour redistribution imaging. However, both redistribution and reinjection images are needed since they complement each other

  10. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients.

    Science.gov (United States)

    Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine

    2016-11-01

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.

  11. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  12. Myocardial perfusion scintigraphy with technetium99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, A.T.; Chacon, D.; Ponce, F.; Torres, M.; Llerena, L.; Lopez, A.; Cabrera, O.; Maltas, A.M.; Carrillo, R.

    2002-01-01

    Aim: To assess the value of myocardial perfusion scintigraphy for coronary artery disease (CAD) in women, we compared the results of a technetium99m-methoxy-isobutyl-isonitrile ( 99m Tc-MIBI) scintigraphy with those of a coronary angiography in a group of women referred for evaluation of chest pain. Material and Methods: Twenty women, 15 of them postmenopausal, were included. A 99m Tc-MIBI myocardial scintigraphy with one-day protocol (rest-stress) was performed. When needed, a combined stress (ergometric plus dipyridamole) was used. Both qualitative and quantitative regional uptake analysis was done. In patients with normal coronary arteries and positive myocardial scintigraphies, measurements were made of serum cholesterol and triglycerides (CHOD-PAD enzymatic colorimetric test), and lipoprotein(a) -Lp(a)- (BioSCREEN Lp(a) method). Results: Change in regional uptake (stress/rest) was as follows: during stress 99m Tc-MIBI, 116 segments had normal uptake (from 93±9% to 94±7%), 52 had moderately reduced uptake (from 67±9% to 75±17%), and 12 had severely reduced uptake (from 33±9% to 64±28%). Qualitative and quantitative analysis coincided in 18 cases. The two non-coincident cases were patients in whom qualitative analysis and coronary angiography were normal, but on quantitative analysis it appeared a reversible defect in one case and a 'reverse redistribution' pattern in the other. Breast attenuation defects were detected in four cases. Myocardial scintigraphy and coronary angiography coincided in 70% cases (figure). The remainder 30% was constituted by patients with positive scintigraphy and normal coronary arteries; among these cases, the 71% were postmenopausal and had systolic hypertension, chest pain at rest, positive ergometric test and hypercholesterolemia (table). Conclusion: We concluded that 99m Tc-MIBI myocardial scintigraphy can help in the CAD diagnosis in postmenopausal women

  13. Cerebral abnormalities in cocaine abusers: Demonstration by SPECT perfusion brain scintigraphy. Work in progress

    International Nuclear Information System (INIS)

    Tumeh, S.S.; Nagel, J.S.; English, R.J.; Moore, M.; Holman, B.L.

    1990-01-01

    Single photon emission computed tomography (SPECT) perfusion brain scans with iodine-123 isopropyl iodoamphetamine (IMP) were obtained in 12 subjects who acknowledged using cocaine on a sporadic to a daily basis. The route of cocaine administration varied from nasal to intravenous. Concurrent abuse of other drugs was also reported. None of the patients were positive for human immunodeficiency virus. Brain scans demonstrated focal defects in 11 subjects, including seven who were asymptomatic, and no abnormality in one. Among the findings were scattered focal cortical deficits, which were seen in several patients and which ranged in severity from small and few to multiple and large, with a special predilection for the frontal and temporal lobes. No perfusion deficits were seen on I-123 SPECT images in five healthy volunteers. Focal alterations in cerebral perfusion are seen commonly in asymptomatic drug users, and these focal deficits are readily depicted by I-123 IMP SPECT

  14. Preliminary studies of pulmonary perfusion scanning in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Shi Rongfang; Liu Xiujie; Wang Yanqun

    1986-01-01

    A comparative analysis of pulmonary perfusion scanning through cardiac catheterization of 57 patients including 32 patients with congenital heart disease, 8 patients with chronic pulmonary thromboembolism and 7 patients with primary pulmonary hypertension is reported. The lung scintigram obtained with In-113m or Tc-99m-MAA represents the distribution of pulmonary blood. It has been found that the lung scintigram was abnormal in patients of congenital heart disease with pulmonary hypertension (i. e. pulmonary artery pressure between 41-80 mmHg) and the extent of radoiactive regional defects is proportional to the level of pulmonary hypertension. The results of the analysis indicated that pulmonary perfusion scanning being a noninvasive technique would be a useful method in evaluating the level of pulmonary hypertension in patients with left to right shunt before and after surgical operation

  15. Noninvasive detection of regional myocardial perfusion abnormality with /sup 201/Tl and /sup 81/Rb

    Energy Technology Data Exchange (ETDEWEB)

    Narita, M; Usami, M; Kurihara, T; Kawararadani, H; Kanao, K

    1977-05-01

    Myocardial scintigrams were performed at rest and during exercise using /sup 201/Tl and /sup 81/Rb. Patients underwent graded ergometer exercise stress tests. In normals, myocardial images were horse-shoe or O-shaped and concentration of radionuclide was relatively uniform throughout the myocardium. In 13 patients with old myocardial infarctions, and abnormal Q waves, regional myocardial perfusion defects (cold area) were detected. Their locations correlated with sites of the abnormal Q waves. Two patients had no abnormal Q waves at the examination, but their scintigrams showed cold areas, the locations of which coincided with coronary angiographic findings. Exercise stress ECG and stress scintigrams were performed. Myocardial perfusion defects, which developed from exercise stress, were detected in 9 of 10 positive exercise ECG patients, 2 of 4 equivocal exercise ECG patients, and 2 of 10 negative exercise ECG patients. These 2 patients (exercise ECG (-), stress scintigram (+)) had typical angina. Findings of exercise stress scintigrams coincided better with clinical findings than did those of exercise ECG. These scintigraphic methods appear to be excellent for detection of noninvasive coronary heart disease noninvasively.

  16. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  17. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy

    International Nuclear Information System (INIS)

    Rubini, G.; Sebastiani, M.

    2000-01-01

    It is here reported on the importance of the integration of data obtained from digital coronary angiography and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography in evaluationing the hemodynamic significance of coronary arteriovenous fistulae. Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, trans thoracic echocardiography, stress electrocardiogram and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography. Stress/rest 99m Tc sestamibi myocardial perfusion single photon tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a seclusive stenosis of the right coronary artery and anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic results were obtained

  18. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  19. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  20. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    International Nuclear Information System (INIS)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-01-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques

  1. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  2. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  3. Myocardial perfusion and left ventricular function early after successful PTCA in 1-vessel coronary artery diseases

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Kaiser, W.; Hanke, H.; Mueller-Schauenburg, W.; Karsch, K.R.; Seipel, L.

    1994-01-01

    Myocardial perfusion ( 201 Tl-ECT) and contractile function ( 99m Tc-ventriculography) were studied during exercise and rest 3 to 6 days after PTCA in 20 patients (11 with stable and 9 with unstable angina pectoris). All patients had single vessel disease and no previous myocardial infarction. During exercise after PTCA the ejection fraction increased for 3 to 5% and no regional wall motion abnormalities, ST-segment depression or perfusion defects occurred (with exception in one patient with very early restenosis). Therefore, perfusion and wall motion were completely normalized at test and during exercise within days after technically successful PTCA even in patients with previously unstable angina pectoris. Pathological stress test results after this time should thus be attributed to other causes e.g. early restenosis, multivessel disease, false positive tests) and are not due to the specific situation early after PTCA. (orig.) [de

  4. Improvement of myocardial perfusion detected by 201Tl scintigraphy on cardiac rehabilitation for patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li, Linxue; Nohara, Ryuji; Makita, Shigeru

    1996-01-01

    The effect of cardiac rehabilitation (mean 70±48 months) on myocardial perfusion was assessed using thallium-201 ( 201 Tl) exercise study in 63 patients with coronary artery disease (CAD). Subjects were those in a rehabilitation group (Rh=42) participating in supervised sports training two to three times per week and the control group (Ct=21) not taking active daily exercise. The interval between two 201 Tl SPECT studies was 19±16 months. After physical training, total duration of the exercise test increased from 443±112 to 536±121 seconds (+19%) in the Rh group, and from 484±129 to 432±115 seconds in the Ct group (-10.7%) (p 2 to 269.8±58 x 10 2 in the Rh group and decreased from 218.7±40 x 10 2 to 216.6±76 x 10 2 (p 201 Tl myocardial perfusion defect on exercise improved more in 54.8% (stress 59.5%, rest 35.7%) in the Rh group than in the Ct group (9.5%, p 201 Tl perfusion defect decreased from 68 (23.1%) to 49 regions (16.7%) of 294 total myocardial regions in the Rh group on exercise. However. it increased from 39 (26.5%) to 44 (29.9%) regions of 147 regions in the Ct group (p<0.01). Thus, cardiac rehabilitation increases exercise tolerance with improvement of myocardial perfusion. suggesting that cardiac rehabilitation is an advisable and effective treatment for patients with ischemic heart disease. (author)

  5. A diagnostic strategy for pulmonary embolism based on standardised pretest probability and perfusion lung scanning: a management study

    International Nuclear Information System (INIS)

    Miniati, Massimo; Monti, Simonetta; Bauleo, Carolina; Scoscia, Elvio; Tonelli, Lucia; Dainelli, Alba; Catapano, Giosue; Formichi, Bruno; Di Ricco, Giorgio; Prediletto, Renato; Carrozzi, Laura; Marini, Carlo

    2003-01-01

    Pulmonary embolism remains a challenging diagnostic problem. We developed a simple diagnostic strategy based on combination of assessment of the pretest probability with perfusion lung scan results to reduce the need for pulmonary angiography. We studied 390 consecutive patients (78% in-patients) with suspected pulmonary embolism. The pretest probability was rated low ( 10%, ≤50%), moderately high (>50%, ≤90%) or high (>90%) according to a structured clinical model. Perfusion lung scans were independently assigned to one of four categories: normal; near-normal; abnormal, suggestive of pulmonary embolism (wedge-shaped perfusion defects); abnormal, not suggestive of pulmonary embolism (perfusion defects other than wedge shaped). Pulmonary embolism was diagnosed in patients with abnormal scans suggestive of pulmonary embolism and moderately high or high pretest probability. Patients with normal or near-normal scans and those with abnormal scans not suggestive of pulmonary embolism and low pretest probability were deemed not to have pulmonary embolism. All other patients were allocated to pulmonary angiography. Patients in whom pulmonary embolism was excluded were left untreated. All patients were followed up for 1 year. Pulmonary embolism was diagnosed non-invasively in 132 patients (34%), and excluded in 191 (49%). Pulmonary angiography was required in 67 patients (17%). The prevalence of pulmonary embolism was 41% (n=160). Patients in whom pulmonary embolism was excluded had a thrombo-embolic risk of 0.4% (95% confidence interval: 0.0%-2.8%). Our strategy permitted a non-invasive diagnosis or exclusion of pulmonary embolism in 83% of the cases (95% confidence interval: 79%-86%), and appeared to be safe. (orig.)

  6. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  7. Normalization of reverse redistribution of thallium-201 with procainamide pretreatment in Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Nii, T.; Nakashima, Y.; Nomoto, J.; Hiroki, T.; Ohshima, F.; Arakawa, K.

    1991-01-01

    Stress thallium-201 myocardial perfusion imaging was performed in a patient with Wolff-Parkinson-White syndrome. Reverse redistribution phenomenon was observed in the absence of coronary artery disease. This seems to be the first report of normalization of this phenomenon in association with reversion of accessory pathway to normal atrioventricular conduction after pretreatment with procainamide

  8. Normalization of reverse redistribution of thallium-201 with procainamide pretreatment in Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nii, T.; Nakashima, Y.; Nomoto, J.; Hiroki, T.; Ohshima, F.; Arakawa, K. (Fukuoka Univ. School of Medicine (Japan))

    1991-03-01

    Stress thallium-201 myocardial perfusion imaging was performed in a patient with Wolff-Parkinson-White syndrome. Reverse redistribution phenomenon was observed in the absence of coronary artery disease. This seems to be the first report of normalization of this phenomenon in association with reversion of accessory pathway to normal atrioventricular conduction after pretreatment with procainamide.

  9. Rest/stress myocardial perfusion imaging: A means to prevent missed acute ischemic coronary syndrome diagnoses

    International Nuclear Information System (INIS)

    Fink-Bennett, D.; Pattekar, A.M.

    2002-01-01

    Aim: The sensitivity and specificity of rest/stress (R/S) myocardial perfusion imaging (MPI) in detecting an acute ischemic coronary syndrome (AICS) was determined in 100 consecutive patients (pts) admitted to the Chest Pain Clinic-Observation Unit (CPC-OU) with chest pain (CP) of suspected cardiac etiology and a negative (neg) or non diagnostic (dx) EKG. There were 57 females and 43 males, 30-83 years of age. 50 studies were performed from 1/15/98 to 4/2/98; 50 from 11/19/99 to 1/10/00. Material and Methods: An AICS was deemed present if a reversible perfusion defect was demonstrated scintigraphically; a ?50% luminal narrow angiographically. No AICS if the pt had a normal R/S MPI, a fixed defect with normal wall motion and thickening, a neg cardiac catheterization, or was free of cardiac symptoms and had no history of a vascular event for 2-3 years post CPC-OU admission. 13 pts with a positive MPI had a cardiac catheterization, none with a neg MPI. SPECT rest MPI's were performed 30-90 minutes (mins) post 10.0 mCi of technetium 99m Sestamibi. SPECT stress MPI's were performed following a 6-8 hour acute myocardial infarction enzyme (CP-MB/Troponin 1) rule out and 30-90 mins post 30.0 mCi of technetium 99m Sestamibi. Results: 29 pts were lost to follow-up. There were 12 true positive, 5 false positive, 54 true negative and 0 false negative studies. The sensitivity, specificity, positive and negative predictive value of a R/S MPI in detecting an AICS is 100%, 91%, 70% and 100%, respectively. An AICS was detected in 12% of pts admitted to the CPC-OU; a finding that correlates with its reported incidence of 2-12%. 6 were managed medically, 3 required emergent bypass surgery, 3 were stented. Conclusion: R/S MPI should be included in the CPC-OU dx work-up of pts with CP of suspected cardiac etiology to prevent missed AICS diagnoses. Patient care will be optimized and health care and medical malpractice awards for failure to diagnosis an acute myocardial infarction

  10. Brain perfusion abnormalities associated to drug abuse in recent abstinent patients using SPECT 99m Tc-ethylen-cysteinate-dimer (ECD)

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [University of Chile Clinical Hospital Nuclear Medicine Section, Department of Medicine, Santiago (Chile); Pallavicini, Julio [Addiction Unit, Psychiatric Clinic. University of Chile Clinical Hospital (Chile); Gonzalez, Patricio; Jaimovich, Rodrigo [University of Chile Clinical Hospital Nuclear Medicine Section, Department of Medicine, Santiago (Chile); Servat, Monica [Addiction Unit, Psychiatric Clinic. University of Chile Clinical Hospital (Chile); Lavados, Hugo [University of Chile Clinical Hospital Nuclear Medicine Section, Department of Medicine, Santiago (Chile); Arancibia, Pablo [Addiction Unit, Psychiatric Clinic. University of Chile Clinical Hospital (Chile); Padilla, Pamela [University of Chile Clinical Hospital Nuclear Medicine Section, Department of Medicine, Santiago (Chile)

    2009-04-15

    Several substances may produce brain perfusion abnormalities in drug-dependent patients. Their mechanism is unclear and several causes might be involved, especially vasospasm in cocaine consumption. Goal: To characterize residual brain perfusion abnormalities in substance-dependent population. We analyzed brain perfusion in 100 dependant patients (DSM-IV criteria) following a month of strict in-hospital abstinence (age:35{+-}12 y.o.; 86% men); 55% corresponded to poly-drug dependents, mainly to cocaine, alcohol and cannabis; 44% mono-drug users, mostly to alcohol. Results: Single Photon Emission Computed Tomography (SPECT) with 99mTc-ethylen-cysteinate-dimer (ECD) was abnormal in 54% of the cases, with bilateral cortical hypo-perfusion in 89%, focal in 54% and diffuse in 46% of them, with moderate or severe intensity in 61%. The abnormal perfusion group's age was 38{+-}12 versus 31{+-}10 years in the normal SPECT group (P=0.005) with a consumption period of 16{+-}11 versus 11{+-}8 years, respectively (P=0.043). Only 29% of women had abnormal perfusion versus 58% of men (P=0.047). Abnormal brain perfusion in 64% of mono and 45% in poly-drug dependents (P=0.07). Psychometric tests performed in 25 patients demonstrated association between perfusion defects and cognitive abnormalities. Relative risk for abnormal psychometric test was 2.5 [95%;CI=1.1-5.6] for abnormal SPECT. Conclusion: Dependent population after a month of abstinence persists with cortical brain perfusion abnormalities, associated to age, sex and type of drug consumption.

  11. Comparison of parathyroid hormone and G-CSF treatment after myocardial infarction on perfusion and stem cell homing.

    Science.gov (United States)

    Huber, Bruno C; Fischer, Rebekka; Brunner, Stefan; Groebner, Michael; Rischpler, Christoph; Segeth, Alexander; Zaruba, Marc M; Wollenweber, Tim; Hacker, Marcus; Franz, Wolfgang-Michael

    2010-05-01

    Mobilization of stem cells by granulocyte colony-stimulating factor (G-CSF) was shown to have protective effects after myocardial infarction (MI); however, clinical trials failed to be effective. In search for alternative cytokines, parathyroid hormone (PTH) was recently shown to promote cardiac repair by enhanced neovascularization and cell survival. To compare the impact of the two cytokines G-CSF and PTH on myocardial perfusion, mice were noninvasively and repetitively investigated by pinhole single-photon emission computed tomography (SPECT) after MI. Mobilization and homing of bone marrow-derived stem cells (BMCs) was analyzed by fluorescence-activated cell sorter (FACS) analysis. Mice (C57BL/6J) were infarcted by left anterior descending artery ligation. PTH (80 mug/kg) and G-CSF (100 mug/kg) were injected for 5 days. Perfusion defects were determined by (99m)Tc-sestamibi SPECT at days 6 and 30 after MI. The number of BMCs characterized by Lin(-)/Sca-1(+)/c-kit(+) cells in peripheral blood and heart was analyzed by FACS. Both G-CSF and PTH treatment resulted in an augmented mobilization of BMCs in the peripheral blood. Contrary to G-CSF and controls, PTH and the combination showed significant migration of BMCs in ischemic myocardium associated with a significant reduction of perfusion defects from day 6 to day 30. A combination of both cytokines had no additional effects on migration and perfusion. In our preclinical model, SPECT analyses revealed the functional potential of PTH reducing size of infarction together with an enhanced homing of BMCs to the myocardium in contrast to G-CSF. A combination of both cytokines did not improve the functional outcome, suggesting clinical applications of PTH in ischemic heart diseases.

  12. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Lee, Won Woo; So, Young; Kim, Ki Bong; Lee, Dong Soo

    2014-01-01

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), 201 Tl perfusion status at rest, 201 Tl 24 hours redistribution and systolic wall thickening of 99m Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p 201 Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  13. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease

    International Nuclear Information System (INIS)

    Bailey, I.K.; Griffith, L.S.C.; Rouleau, J.; Strauss, H.W.; Pitt, B.

    1977-01-01

    The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise studies in any of the normal subjects. Fifty-six percent of patients with CAD developed new perfusion defects with exercise compared to 38 percent who developed ischemic ST-segment depression (P < 0.02). However, when chest pain and/or ST depression were considered indices of ischemia, the sensitivity of exercise testing and thallium-201 MPI was similar. The increased sensitivity of MPI compared to ST-segment depression on the ECG was due to patients with baseline ECG abnormalities and those who failed to achieve 85 percent of predicted maximum heart rate with exercise. Analysis of the exercise results according to the extent of coronary artery disease revealed a progressive increase in both positive ECGs and MPI with the number of vessels involved. In patients with single vessel disease the MPI was more sensitive than the ECG (P < 0.02). The combination of the rest and exercise ECG, MPI and chest pain during exercise failed to identify 11 percent of patients with CAD. Exercise thallium-201 MPI is a useful adjunct to conventional exercise testing particularly when evaluating patients with abnormal resting ECGs, those who develop ventricular conduction defects or arrhythmias during exercise, and those who fail to achieve their predicted heart rate because of fatigue or breathlessness

  14. Reversibility of Defective Hematopoiesis Caused by Telomere Shortening in Telomerase Knockout Mice.

    Directory of Open Access Journals (Sweden)

    Aparna Raval

    Full Text Available Telomere shortening is common in bone marrow failure syndromes such as dyskeratosis congenita (DC, aplastic anemia (AA and myelodysplastic syndromes (MDS. However, improved knowledge of the lineage-specific consequences of telomere erosion and restoration of telomere length in hematopoietic progenitors is required to advance therapeutic approaches. We have employed a reversible murine model of telomerase deficiency to compare the dependence of erythroid and myeloid lineage differentiation on telomerase activity. Fifth generation Tert-/- (G5 Tert-/- mice with shortened telomeres have significant anemia, decreased erythroblasts and reduced hematopoietic stem cell (HSC populations associated with neutrophilia and increased myelopoiesis. Intracellular multiparameter analysis by mass cytometry showed significantly reduced cell proliferation and increased sensitivity to activation of DNA damage checkpoints in erythroid progenitors and in erythroid-biased CD150hi HSC, but not in myeloid progenitors. Strikingly, Cre-inducible reactivation of telomerase activity restored hematopoietic stem and progenitor cell (HSPC proliferation, normalized the DNA damage response, and improved red cell production and hemoglobin levels. These data establish a direct link between the loss of TERT activity, telomere shortening and defective erythropoiesis and suggest that novel strategies to restore telomerase function may have an important role in the treatment of the resulting anemia.

  15. Interdependence between measures of extent and severity of myocardial perfusion defects provided by automatic quantification programs

    DEFF Research Database (Denmark)

    El-Ali, Henrik Hussein; Palmer, John; Carlsson, Marcus

    2005-01-01

    To evaluate the accuracy of the values of lesion extent and severity provided by the two automatic quantification programs AutoQUANT and 4D-MSPECT using myocardial perfusion images generated by Monte Carlo simulation of a digital phantom. The combination between a realistic computer phantom and a...

  16. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  17. Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software

    Energy Technology Data Exchange (ETDEWEB)

    Ebersberger, Ullrich [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Marcus, Roy P.; Nikolaou, Konstantin; Bamberg, Fabian [University of Munich, Institute of Clinical Radiology, Munich (Germany); Schoepf, U.J.; Gray, J.C.; McQuiston, Andrew D. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Lo, Gladys G. [Hong Kong Sanatorium and Hospital, Department of Diagnostic and Interventional Radiology, Hong Kong (China); Wang, Yining [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Department of Radiology, Beijing (China); Blanke, Philipp [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany); Geyer, Lucas L. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University of Munich, Institute of Clinical Radiology, Munich (Germany); Cho, Young Jun [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Konyang University College of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Scheuering, Michael; Canstein, Christian [Siemens Healthcare, CT Division, Forchheim (Germany); Hoffmann, Ellen [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany)

    2014-01-15

    To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. (orig.)

  18. Quantitative Assessment of Free Flap Viability with CEUS Using an Integrated Perfusion Software.

    Science.gov (United States)

    Geis, S; Klein, S; Prantl, L; Dolderer, J; Lamby, P; Jung, E-M

    2015-12-01

    New treatment strategies in oncology and trauma surgery lead to an increasing demand for soft tissue reconstruction with free tissue transfer. In previous studies, CEUS was proven to detect early flap failure. The aim of this study was to detect and quantify vascular disturbances after free flap transplantation using a fast integrated perfusion software tool. From 2011 to 2013, 33 patients were examined by one experienced radiologist using CEUS after a bolus injection of 1-2.4 ml of SonoVue(®). Flap perfusion was analysed qualitatively regarding contrast defects or delayed wash-in. Additionally, an integrated semi-quantitative analysis using time-intensity curve analysis (TIC) was performed. TIC analysis of the transplant was conducted on a centimetre-by-centimetre basis up to a penetration depth of 4 cm. The 2 perfusion parameters "Time to PEAK" and "Area under the Curve" were compared in patients without complications vs. patients with minor complications or complete flap loss to figure out significant differences. TtoPk is given in seconds (s) and Area is given in relative units (rU) Results: A regular postoperative process was observed in 26 (79%) patients. In contrast, 5 (15%) patients with partial superficial flap necrosis, 1 patient (3%) with complete flap loss and 1 patient (3%) with haematoma were observed. TtoPk revealed no significant differences, whereas Area revealed significantly lower perfusion values in the corresponding areas in patients with complications. The critical threshold for sufficient flap perfusion was set below 150 rU. In conclusion, CEUS is a mobile and cost-effective opportunity to quantify tissue perfusion and can even be used almost without any restrictions in multi-morbid patients with renal and hepatic failure. © Georg Thieme Verlag KG Stuttgart · New York.

  19. The effect of patent ductus arteriosus on pre-ductal and post-ductal perfusion index in preterm neonates.

    Science.gov (United States)

    Nitzan, Itamar; Hammerman, Cathy; Fink, Daniel; Nitzan, Meir; Koppel, Robert; Bromiker, Ruben

    2018-06-26

    The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus - PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA - hsPDA), which may lead to severe neonatal morbidity. The study objective was to find the relationship between hsPDA and perfusion index (PI), a photoplethysmographic parameter, related to systemic perfusion. Approach. PI measures the relative systolic increase in tissue light absorption due to the systolic increase in the tissue blood volume. PI has been found to be directly related to tissue perfusion, and is therefore expected to be affected by hsPDA. Main results. PI was found to be higher in preterm neonates with hsPDA after first week of life, in comparison to those with closed DA, despite the lower systemic perfusion, probably due to reverse flow during diastole. Significance. In our study, perfusion index increased despite the lower systemic perfusion, indicating that in neonates with hsPDA, perfusion index is not necessarily a measure of perfusion. Nevertheless, PI can be used as a screening tool for suspicious PDA, in order to select a relatively small group of neonates for a more definitive examination by echocardiography, which is not suitable for universal screening. . © 2018 Institute of Physics and Engineering in Medicine.

  20. Assessment of residual tissue viability by exercise testing in recent myocardial infarction: comparison of the electrocardiogram and myocardial perfusion scintigraphy.

    Science.gov (United States)

    Margonato, A; Ballarotto, C; Bonetti, F; Cappelletti, A; Sciammarella, M; Cianflone, D; Chierchia, S L

    1992-04-01

    The assessment of residual myocardial viability in infarcted areas is relevant for subsequent management and prognosis but requires expensive technology. To evaluate the possibility that simple, easily obtainable clinical markers may detect the presence of within-infarct viable tissue, the significance of exercise-induced ST elevation occurring in leads exploring the area of a recent Q wave myocardial infarction was assessed. Twenty-five patients with recent (less than 6 months) myocardial infarction were studied. All had angiographically documented coronary artery disease, diagnostic Q waves (n = 24) or negative T waves (n = 25) on the rest 12-lead electrocardiogram and exhibited during exercise greater than or equal to 1.5 mm ST segment elevation (n = 17) or isolated T wave pseudonormalization (n = 8) in the infarct-related leads. ST-T wave changes were reproduced in all patients during thallium-201 exercise myocardial scintigraphy. A fixed perfusion defect was observed in 24 of the 25 patients. A reversible defect was seen in 16 (94%) of 17 patients who exhibited transient ST elevation during exercise but in only 4 (50%) of the 8 patients who had only T wave pseudonormalization. In conclusion, in patients with recent myocardial infarction, analysis of simple ST segment variables obtained during exercise testing may allow a first-line discrimination of those who may potentially benefit from a revascularization procedure.

  1. Pulmonary artery perfusion versus no pulmonary perfusion during cardiopulmonary bypass in patients with COPD

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Sundskard, Martin M; Jonassen, Thomas

    2016-01-01

    INTRODUCTION: Absence of pulmonary perfusion during cardiopulmonary bypass (CPB) may be associated with reduced postoperative oxygenation. Effects of active pulmonary artery perfusion were explored in patients with chronic obstructive pulmonary disease (COPD) undergoing cardiac surgery. METHODS: 90...... perfusion with normothermic oxygenated blood during cardiopulmonary bypass appears to improve postoperative oxygenation in patients with COPD undergoing cardiac surgery. Pulmonary artery perfusion with hypothermic HTK solution does not seem to improve postoperative oxygenation. TRIAL REGISTRATION NUMBER...

  2. Improved repair of bone defects with prevascularized tissue-engineered bones constructed in a perfusion bioreactor.

    Science.gov (United States)

    Li, De-Qiang; Li, Ming; Liu, Pei-Lai; Zhang, Yuan-Kai; Lu, Jian-Xi; Li, Jian-Min

    2014-10-01

    Vascularization of tissue-engineered bones is critical to achieving satisfactory repair of bone defects. The authors investigated the use of prevascularized tissue-engineered bone for repairing bone defects. The new bone was greater in the prevascularized group than in the non-vascularized group, indicating that prevascularized tissue-engineered bone improves the repair of bone defects. [Orthopedics. 2014; 37(10):685-690.]. Copyright 2014, SLACK Incorporated.

  3. Reverse redistribution in dipyridamole-loading thallium-201 images using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Mori, Kiyoo; Masuda, Masanosuke; Bunko, Hisashi.

    1986-01-01

    Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and a stress image was obtained 10 min after the injection of two mCi 201 Tl. The myocardial image of Tl was analyzed by single photon emission computed tomography and its washout rate was calculated by the segmental ROI method. Myocardial function and the motion of the left ventricular wall were analyzed by 99m Tc-RBC-gated cardiac pool imaging. Reverse redistribution was noted in 27 (21.6 %) of 125 consecutive Tl dipyridamole and redistribution myocardial imaging studies. The stress image demonstrated normal perfusion (group 1) and reduced perfusion (group 2) of Tl. Group 1 consisted of 17 patients with diabetes mellitus, supraventricular arrhythmias, hypertension, and others. Group 2 consisted of 10 patients with subendocardial infarction, diabetes mellitus, and hypertension, and others. The percentage prevalence of reverse redistribution among patients with supraventricular arrhythmia was 62.5 % (five of eight patients), with subendocardial infarction 60.0 % (three of five), with hypertension 42.8 % (six of 14), and with diabetes mellitus 40.0 % (eight of 20), while in those with transmyocardial infarction and angina pectoris no reverse redistribution percentage was found. The washout rate of Tl in normal perfusion areas was 44.0 ± 12.8 %, the reverse redistribution of group 1 was 47.4 ± 12.8 %, and of group 2 was 51.2 ± 8.2 %. The washout rate of the reverse redistribution of group 2 was significantly greater than that of the normal areas. In gated cardiac pool imaging, patients in group 2 had significantly larger areas showing abnormal contraction of the left ventricular wall and significantly lower ejection fraction than did group 1. In the electrocardiogram ST segment depression was noted more frequently in group 2 than group 1. No Q wave was present in the corresponding reverse redistribution area. (J.P.N.)

  4. Thallium-201 myocardial perfusion scintigraphy to evaluate patients with chest pain (preliminary study)

    International Nuclear Information System (INIS)

    Mahfouz, M.; Elhaddad, S.; Elghoneimy, I.; Elmesidy, S.; Haggag, F.; Sbdou, S.; Dayem, K.A.; Ezzeldiy, H.

    1985-01-01

    201 Tl perfusion scintigraphy for the diagnosis of coronary artery disease was carried out in 25 patients of mean age years, presenting with chest pain. Scintiscan were obtained at rest and after exercise and were compared with ECG studies at rest and after exercise. In all patients with previous myocardial infarctions, perfusion defects were present at rest, two of these patients showed abnormal stress scintigraphy consistent with a new ischemic response which was not detected by the stress ECG. In 3 out of the 8 patients with normal ECG, in 2 out of the 4 patients with response suggesting ischemia and in 4 out of the 7 patients with definite ECG proof of ischemia infarction was detected by 201 Tl. In all the previous, resting and exercise ECG failed to show evidence of infarction.1 fig.,2 tab

  5. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  6. Effects of steroids and sex reversal on intestinal absorption of L-[14C]leucine in vivo, in rainbow trout, Salmo gairdneri

    International Nuclear Information System (INIS)

    Habibi, H.R.; Ince, B.W.

    1983-01-01

    The effects of steroids (17 alpha-methyltestosterone (MT), 17 beta-oestradiol (E2)), and of sex reversal (XX male) on intestinal absorption and accumulation of L-[ 14 C]leucine (5 mM), were investigated in unanaesthetized rainbow trout (Salmo gairdneri), using an in vivo gut perfusion technique. Each steroid was luminally perfused through the gut at a concentration of 50 micrograms/ml perfusate, during five separate perfusions carried out on the same fish at 30-min intervals (perfusion periods 1 to 5), for a total of 120 min at 14 degrees. Experiments were also conducted on masculinized, genetically female trout (XX male) with steroid-free perfusate. MT treatment significantly increased the intestinal absorption of radioleucine during periods 1 and 2, whilst E2 was without effect. Neither MT nor E2 influenced intestinal accumulation (mid- and hindgut) of radioleucine, and accumulation of 14 C-solutes in skeletal muscle. Sex reversal, however, whilst having no effect on leucine absorption, nevertheless significantly increased intestinal accumulation of radioleucine, and accumulation of 14 C-solutes in skeletal muscle. The effects observed in the present study are in agreement with previous work in trout using everted gut sac preparations. It is suggested that the growth-promoting effects of anabolic-androgenic steroids in fish may be partly explained by their action on gastrointestinal function

  7. Perfusion dyssynchrony analysis

    NARCIS (Netherlands)

    Chiribiri, A.; Villa, A.D.M.; Sammut, E.; Breeuwer, M.; Nagel, E.

    2015-01-01

    AIMS: We sought to describe perfusion dyssynchrony analysis specifically to exploit the high temporal resolution of stress perfusion CMR. This novel approach detects differences in the temporal distribution of the wash-in of contrast agent across the left ventricular wall. METHODS AND RESULTS:

  8. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  9. Reversible hemispheric hypoperfusion in two cases of SMART syndrome.

    Science.gov (United States)

    Wai, Karmen; Balabanski, Anna; Chia, Nicholas; Kleinig, Timothy

    2017-09-01

    Stroke-like migraine attacks after radiation therapy (SMART) syndrome manifests as prolonged episodes of cortical dysfunction, years after cranial irradiation. We present two cases demonstrating reversible hemispheric hypoperfusion. Case 1 presented with left hemispheric symptoms following previous similar episodes. CT perfusion (CTP) demonstrated reversible hemispheric hypoperfusion; subsequent investigations were consistent with SMART syndrome. Case 2 presented following the third episode of a hemispheric syndrome with near-identical CTP abnormalities. L-arginine was administered with rapid reversal of clinical and CTP abnormalities. We conclude that SMART syndrome may demonstrate significant hypoperfusion on hyperacute CTP without subsequent infarction. Impaired cerebrovascular autoregulation probably contributes to cortical dysfunction in SMART syndrome. L-arginine warrants investigation as a potential treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Koehli, M. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Monbaron, D.; Gaillard, R.C.; Ruiz, J. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Prior, J.O.; Bischof Delaloye, A. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Calcagni, M.L. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Dept. of Cardiology, Univ. Hospital Lausanne (Switzerland); Fivaz-Arbane, M.; Stauffer, J.C. [Inst. of Nuclear Medicine, Univ. Cattolica del Sacro Cuore, Roma (Italy)

    2006-07-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 {+-} 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had on excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  11. Observer variability in the evaluation of dual-isotope Tl-201/Tc-99m sestamibi rest/stress myocardial perfusion SPECT in men and women with known or suspected stable angina pectoris

    DEFF Research Database (Denmark)

    Johansen, Allan; Høilund-Carlsen, Poul Flemming; Christensen, Henrik Wulff

    2004-01-01

    BACKGROUND: Observer variability of dual-isotope myocardial perfusion imaging (MPI) with single photon emission computed tomography has rarely been investigated. The aim of our study was to evaluate the interpretive reproducibility with this technique. METHODS AND RESULTS: We report on 507 patients...... rate of abnormal MPI was 49% (59% in men and 34% in women). The interobserver agreement for the whole group (kappa = 0.85) and for men and women separately (kappa = 0.86 and 0.82, respectively) was excellent with regard to the overall diagnosis (normal, reversible, or fixed defects) as well as left...... anterior descending and left circumflex artery vascular territories (kappa = 0.85 and 0.82, respectively). However, in the right coronary artery territory, agreement was excellent in men (kappa = 0.83) but moderate in women (kappa = 0.57). CONCLUSIONS: In a relatively large group of men and women...

  12. Defect engineering of ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.H. [Center for Materials Research and Department of Physics and Astronomy, Washington State University, Pullman, WA 99164-2711 (United States)], E-mail: m_weber@wsu.edu; Selim, F.A.; Solodovnikov, D.; Lynn, K.G. [Center for Materials Research and Department of Physics and Astronomy, Washington State University, Pullman, WA 99164-2711 (United States)

    2008-10-31

    The defect responsible for the transparent to red color change of nominally undoped ZnO bulk single crystals is investigated. Upon annealing in the presence of metallic Zn as reported by Halliburton et al. and also Ti and Zr a native defect forms with an energy level about 0.7 eV below the conduction band. This change is reversible upon annealing in oxygen. Optical transmission data along with positron depth profiles and annealing studies are combined to identify the defect as oxygen vacancies. Vacancy clustering occurs at about 500 deg. C if isolated zinc and oxygen vacancies. In the absence of zinc vacancies, clusters form at about 800 deg. C.

  13. Defect engineering of ZnO

    International Nuclear Information System (INIS)

    Weber, M.H.; Selim, F.A.; Solodovnikov, D.; Lynn, K.G.

    2008-01-01

    The defect responsible for the transparent to red color change of nominally undoped ZnO bulk single crystals is investigated. Upon annealing in the presence of metallic Zn as reported by Halliburton et al. and also Ti and Zr a native defect forms with an energy level about 0.7 eV below the conduction band. This change is reversible upon annealing in oxygen. Optical transmission data along with positron depth profiles and annealing studies are combined to identify the defect as oxygen vacancies. Vacancy clustering occurs at about 500 deg. C if isolated zinc and oxygen vacancies. In the absence of zinc vacancies, clusters form at about 800 deg. C

  14. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  15. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  16. A capillary-based perfusion phantom for simulation of brain perfusion for MRI

    International Nuclear Information System (INIS)

    Maciak, A.; Kronfeld, A.; Mueller-Forell, W.; Wille, C.; Kempski, O.; Stoeter, P.

    2010-01-01

    Purpose: The measurement of the CBF is a non-standardized procedure and there are no reliable gold standards. This abstract shows a capillary-based perfusion-phantom for CE-DSC-MRI. It has equivalent flow properties to those within the tissue capillary system of the human brain and allows the validation of the Siemens Perfusion (MR) software. Materials and Methods: The perfusion phantom consists of a dialyzer for the simulation of the capillary system, a feeding tube for simulation of the AIF and a pulsatile pump for simulation of the heart. Using this perfusion phantom, the exact determination of the gold standard CBF due to the well-known geometry of the phantom is easy. It was validated based on different perfusion measurements. These measurements were investigated with standard software (Siemens Perfusion MR). The software determined the CBF within the capillary system. Based on this CBF, a comparison to the gold standard was made with several different flow speeds. After AIF selection, a total of 726 CBF data points were automatically extracted by the software. Results: This results in a comparison of the gold standard CBF to these 726 CBF values. Therefore, a reproducible and reliable deviation estimation between gold standard CBF and measured CBF using the software was computed. It can be shown that the deviation between gold standard and software-based evaluation ranges between 1 and 31 %. Conclusion: There is no significance for any correlation between flow speed and amount of deviation. The mean measured CBF is 11.4 % higher than the gold standard CBF (p-value < 0.001). Using this kind of perfusion-phantom, the validation of different software systems allows reliable conclusions about their quality. (orig.)

  17. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  18. Effects of steroids and sex reversal on intestinal absorption of L-(/sup 14/C)leucine in vivo, in rainbow trout, Salmo gairdneri

    Energy Technology Data Exchange (ETDEWEB)

    Habibi, H.R.; Ince, B.W.

    1983-12-01

    The effects of steroids (17 alpha-methyltestosterone (MT), 17 beta-oestradiol (E2)), and of sex reversal (XX male) on intestinal absorption and accumulation of L-(/sup 14/C)leucine (5 mM), were investigated in unanaesthetized rainbow trout (Salmo gairdneri), using an in vivo gut perfusion technique. Each steroid was luminally perfused through the gut at a concentration of 50 micrograms/ml perfusate, during five separate perfusions carried out on the same fish at 30-min intervals (perfusion periods 1 to 5), for a total of 120 min at 14 degrees. Experiments were also conducted on masculinized, genetically female trout (XX male) with steroid-free perfusate. MT treatment significantly increased the intestinal absorption of radioleucine during periods 1 and 2, whilst E2 was without effect. Neither MT nor E2 influenced intestinal accumulation (mid- and hindgut) of radioleucine, and accumulation of /sup 14/C-solutes in skeletal muscle. Sex reversal, however, whilst having no effect on leucine absorption, nevertheless significantly increased intestinal accumulation of radioleucine, and accumulation of /sup 14/C-solutes in skeletal muscle. The effects observed in the present study are in agreement with previous work in trout using everted gut sac preparations. It is suggested that the growth-promoting effects of anabolic-androgenic steroids in fish may be partly explained by their action on gastrointestinal function.

  19. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  20. Diagnosis and prognosis of elderly patients with coronary artery disease. Assessment with dipyridamole thallium imaging

    International Nuclear Information System (INIS)

    Yamasaki, Fumiyasu; Takata, Jun; Seo, Hiromi; Chikamori, Taishiro; Yamada, Mitsutoshi; Yabe, Toshikazu; Doi, Yoshinori

    1995-01-01

    The diagnostic and prognostic value of dipyridamole perfusion scintigraphy was assessed in 147 patients with coronary artery disease aged 65 years and older. All patients underwent coronary angiography. Dipyridamole perfusion scintigraphy was performed safely in all patients. Multiple regression analysis showed that fixed defect and reversible defect were powerful detectors of coronary lesions, all patients with fixed disease and 94% of patients with only reversible defects had significant coronary lesion. Diffuse slow washout and ST depression were statistically significant for detection multivessel coronary lesions in patients with fixed disease, the sensitivity and specificity of diffuse slow washout and/or ST depression for detecting multivessel coronary lesions were 85% and 74%, respectively. Cox survival analysis identified diffuse slow washout as the best predictor of future cardiac events among the scintigraphic variables. Univariate analysis showed the best predictors were age (≥70), diffuse slow washout, and severe coronary lesions. Multivariate analysis showed diffuse slow washout and severe coronary lesions were the best predictors. Dividing the patients by age (≥70) showed that age and diffuse slow washout were good predictors. Scintigraphic and angiographic parameters found diffuse slow washout was the only good predictor. Dipyridamole perfusion scintigraphy is useful for the noninvasive detection of significant coronary artery disease in the elderly, and for predicting future cardiac events with similar predictability to angiographic findings. (S.Y.)

  1. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  2. 201 thallium scintiscanning during exercise in patients with coronary diseases following administration of the cardioselective beta-blocker atenolol

    International Nuclear Information System (INIS)

    Chlup, J.

    1982-01-01

    Changes of regional myocardial perfusion before and after administration of Atenolol (AT) (5 mg i.v.) were investigated by 201-Tl stress-imaging in 14 patients (PAT) with >= 70% coronary obstructions. Scintigrams were performed in 4 projections; scintigraphic defects (SD) in one of the six LV segments had to be identified in at least 2 projections and to show a decrease of activity >= 25%. All PAT had at least one reversible SD. Results: After AT, stress-induced SDs were unchanged in 11 of the 14 PAT at identical work loads (131 Watt). The total number of reversible defects was 33 before and 28 after AT (n.s.). However, not only the 3 PAT with improved stress scintigrams, but also 6 of the 11 PAT with unchanged abnormal stress scintigrams were clinically improved (ECG normalized, no angina). Thus in almost half of the patients (6/14), the stress ECG was normalized without normalisation of perfusion pattern of thallium scintigrams. We conclude that in these patients subendocardial perfusion was enough improved to meet the reduced metabolic needs but not enough to normalise stress images. (orig./MG) [de

  3. Third-party Reverse logistics platform and method Based on Bilateral Resource Integration

    Directory of Open Access Journals (Sweden)

    Zheng Hong Zhen

    2016-01-01

    Full Text Available Dispersion of reverse logistics resources makes it difficult to create relationships between demanders and providers, thereby the personalized demand for the construction of enterprise reverse logistics cannot be satisfied and the service quality cannot be guaranteed. Aiming at these problems, this paper presents a platform and method of enterprise reverse logistics based on bilateral resource integration (RLBRI. The method creates a third-party reverse logistics platform to accumulate a mass of reverse logistics demanders and providers together. And the platform integrates bilateral resources and acts as an intermediary to establish relationships between two sides. Through the platform, a complete and high-quality business chain for enterprise reverse logistics will be built efficiently. Finally put forward an effective strategy of non-defective reverse logistics depends on the integrity checking service provided by third-party logistics. By using this strategy it can short the distance of non-defective reverse transportation. Computational tests validate the strategy.

  4. Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

    Energy Technology Data Exchange (ETDEWEB)

    Djuric-Stefanovic, A., E-mail: avstefan@eunet.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Saranovic, Dj., E-mail: crvzve4@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Sobic-Saranovic, D., E-mail: dsobic2@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia); Masulovic, D., E-mail: draganmasulovic@yahoo.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Artiko, V., E-mail: veraart@beotel.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

    2015-03-15

    Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (r{sub S}). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (r{sub S} = 0.484, p = 0.002), BV (r{sub S} = 0.637, p < 0.001) and PS (r{sub S} = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (r{sub S} = 0.573, p < 0.001), BV (r{sub S} = 0.849, p < 0.001) and PS (r{sub S} = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy

  5. Nuclear magnetic resonance of perfused tissue

    International Nuclear Information System (INIS)

    Harpen, M.D.; Allison, R.C.

    1986-01-01

    The effect of perfusion on the NMR signal observed in NMR imaging is studied in a phantom and in two isolated perfused canine lungs. It is observed that perfusion in tissue has little effect on longitudinal relaxation times. Transverse relaxation rates are observed to correlate linearly with rates of perfusion, in accordance with a model presented. (author)

  6. Dynamic CT myocardial perfusion imaging identifies early perfusion abnormalities in diabetes and hypertension : Insights from a multicenter registry

    NARCIS (Netherlands)

    Vliegenthart, Rozemarijn; De Cecco, Carlo N.; Wichmann, Julian L.; Meinel, Felix G.; Pelgrim, Gert Jan; Tesche, Christian; Ebersberger, Ullrich; Pugliese, Francesca; Bamberg, Fabian; Choe, Yeon Hyeon; Wang, Yining; Schoepf, U. Joseph

    2016-01-01

    Background: To identify patients with early signs of myocardial perfusion reduction, a reference base for perfusion measures is needed. Objective: To analyze perfusion parameters derived from dynamic computed tomography perfusion imaging (CTPI) in patients with suspected coronary artery disease

  7. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  8. Role of glycolysis in maintenance of the action potential duration and contractile activity in isolated perfused rat heart.

    Science.gov (United States)

    Opie, L H; Tuschmidt, R; Bricknell, O; Girardier, L

    1980-01-01

    1. Changing substrates from glucose to pyruvate in paced isolated rat hearts, perfused by the Langendorff technique at 65 cm H2O with a Krebs-Henseleit bicarbonate buffer, produced effects which are opposite to those of ouabain treatment: negative inotropy, decreased work efficiency, hyperpolarization, increased maximum rate of rise and amplitude of the action potential, increased conduction velocity. 2. All the effects resulting from perfusion with pyruvate can be reversed by adding ouabain at a concentration of 100 microM. 3. The correlation between various tissue metabolises and change in contractile force (delta F), rate of tension development [maximum + (dF/dt)] and rate of relaxation [maximum -(dF/dt)] was studied by multiple linear regression. No significant correlation was found with either glycogen content and tissue lactate or with cAMP and cGMP. A weak negative correlation was found with ATP and phosphocreatine. The strongest correlation was found 76 to 807 nM/g in passing from glucose- to pyruvate-containing perfusion solution. 4. In vitro tests performed with a solution containing high energy phosphates and magnesium at concentrations equal to their calculated values in the cytosol (pH 7.0) showed that a significant negative correlation exists between citrate concentration (range: 1 and 1500 M) and free calcium concentration in the micromole range. 5. It is concluded that the effects of pyruvate (non glucose substrate) perfusion could be mediated by a decrease in cytosolic-free calcium resulting from an increase in intracellular citrate. The observation that all these effects can be reversed by ouabain is taken as a circumstantial evidence of a common mechanism.

  9. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  10. Hydrostatic determinants of cerebral perfusion

    International Nuclear Information System (INIS)

    Wagner, E.M.; Traystman, R.J.

    1986-01-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the radiolabeled microsphere technique. Despite 30-mm Hg reductions in mean arterial pressure or increases in CSF or JV pressure, CBF did not change as long as the perfusion pressure remained greater than approximately 60 mm Hg. However, whenever perfusion pressure was reduced to an average of 48 mm Hg, cerebral blood flow decreased 27% to 33%. These results demonstrate the capacity of the cerebral vascular bed to respond similarly to changes in the perfusion pressure gradient obtained by decreasing mean arterial pressure, increasing JV pressure or increasing CSF pressure, and thereby support the above definition of cerebral perfusion pressure

  11. Induced Pluripotent Stem Cell Models of Progranulin-Deficient Frontotemporal Dementia Uncover Specific Reversible Neuronal Defects

    Science.gov (United States)

    Almeida, Sandra; Zhang, Zhijun; Coppola, Giovanni; Mao, Wenjie; Futai, Kensuke; Karydas, Anna; Geschwind, Michael D.; Tartaglia, M. Carmela; Gao, Fuying; Gianni, Davide; Sena-Esteves, Miguel; Geschwind, Daniel H.; Miller, Bruce L.; Farese, Robert V.; Gao, Fen-Biao

    2012-01-01

    SUMMARY The pathogenic mechanisms of frontotemporal dementia (FTD) remain poorly understood. Here we generated multiple induced pluripotent stem cell (iPSC) lines from a control subject, a patient with sporadic FTD, and an FTD patient with a novel GRN mutation (PGRN S116X). In neurons and microglia differentiated from PGRN S116X iPSCs, the levels of intracellular and secreted progranulin were reduced, establishing patient-specific cellular models of progranulin haploinsufficiency. Through a systematic screen of inducers of cellular stress, we found that PGRN S116X neurons, but not sporadic FTD neurons, exhibited increased sensitivity to staurosporine and other kinase inhibitors. Moreover, the serine/threonine kinase S6K2, a component of the PI3K and MAPK pathways, was specifically downregulated in PGRN S116X neurons. Both increased sensitivity to kinase inhibitors and reduced S6K2 were rescued by progranulin expression. Our findings identify cell-autonomous, reversible defects in patient neurons with progranulin deficiency and provide a new model for studying progranulin-dependent pathogenic mechanisms and testing potential therapies. PMID:23063362

  12. Visualization of hypertrophied papillary muscle mimicking left ventricular mass on gated blood pool and T1-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Bunko, H.; Nakajima, K.; Tonami, N.; Asanoi, H.; Hisada, K.

    1981-01-01

    A sixty-year old man with acute myocardial infarction was incidentally found to have a hypertrophied anterolateral papillary muscle (ALPPM) of the left ventricle on gated blood pool (GBP) and T1-201 myocardial perfusion images. Hypertrophy of the ALPPM was visualized as a movable defect in the lateral basal area on GBP imaging throughout the cardiac cycle and on the TI-201 study as a radionuclide accumulating structure, consistent with the defect in the GBP. A combination of these findings may suggest the presence of a hypertrophied papillary muscle of the left ventricle

  13. Increased accuracy of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy using iterative reconstruction of images

    Directory of Open Access Journals (Sweden)

    Stević Miloš

    2016-01-01

    Full Text Available Background/Aim. Filtered back projection (FBP is a common way of processing myocardial perfusion imaging (MPI studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG, 77 man and 30 woman, aged 32−82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01 and between IR and CAG 0.784 (p < 0.01. The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01. Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  14. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  15. Airways obstruction in survivors of thoracoplasty: reversibility is greater in non-smokers.

    LENUS (Irish Health Repository)

    O'Connor, Terence M

    2012-02-03

    OBJECTIVE: Before the advent of antituberculous chemotherapy, thoracoplasty (TPL) was the definitive form of therapy for cavitary pulmonary tuberculosis. This study aimed to characterize the late functional sequelae of TPL, and to establish the degree of reversibility of any consequent airway obstruction. METHODOLOGY: Pulmonary function was studied in 21 long-term (mean 35 years) survivors of TPL between the years 1990-2001. RESULTS: A mixed obstructive\\/restrictive defect was found in this patient cohort. After inhalation of bronchodilator, marginal increases in FEV(1) and FVC and marginal decreases in FRC, RV and TLC were observed. Maximum mid-expiratory flow rate was severely reduced (28.8% of predicted), but reversibility after inhaled beta(2)-agonist was highest for this parameter of pulmonary function (mean 11%). Smokers had a higher RV (P = 0.04), suggesting hyperinflation, while non-smokers had a larger increase in FEV(1)\\/FVC ratio postbronchodilator (P = 0.004), suggesting more marked reversibility of airways obstruction in this group. CONCLUSIONS: Long-term survivors of TPL have an obstructive as well as a restrictive ventilatory defect. These patients have partial reversibility of the obstructive defect. The degree of reversibility found suggests that bronchodilator therapy may help these patients.

  16. Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction

    International Nuclear Information System (INIS)

    Blood, D.K.; McCarthy, D.M.; Sciacca, R.R.; Cannon, P.J.

    1978-01-01

    Thallium-201 myocardial perfusion scintigraphy was performed after exercise, 4 hours after exercise (redistribution) and after a separate rest injection in 87 patients undergoing coronary arteriography. Significant coronary lesions were present in 62 of the patients. Interpretation of the rest and redistribution scintiscans was the same in 69 patients, 45 of whom had coronary artery disease (CAD). In 16 of the 17 patients with CAD and differing interpretations, defects were present on redistribution scintiscans but not on rest scintiscans; 11 of these patients had evidence of prior transmural myocardial infarction and the other five had an occluded coronary artery supplying the region of the defect. Redistribution scintiscans were more sensitive than rest scintiscans for the detection of prior myocardial infarction (93% vs 54%; P < 0.01). The increased sensitivity was confined to the detection of prior inferior myocardial infarctions. In 36 of 38 patients with persistent perfusion defects on 4-hour redistribution scintiscans, either a prior infarction or an occluded coronary vessel was present. These data demonstrate that redistribution thallium-201 scintiscans may be substituted for conventional rest scintiscans, resulting in reduced cost and radiation exposure to the patients

  17. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    to hold breath on end expiration may help in detection of perfusion defects.

  18. Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening. Comparison with F-18 FDG-PET

    International Nuclear Information System (INIS)

    Maruyama, Atsushi; Hasegawa, Shinji; Paul, A.K.; Xiuli, M.; Yoshioka, Jun; Maruyama, Kaoru; Hori, Masatsugu; Nishimura, Tsunehiko

    2002-01-01

    This study was designed to assess the value of gated SPECT Tc-99m-tetrofosmin (TF) wall thickening (WT) in addition to TF exercise (Ex)/rest myocardial SPECT, in comparison with F-18 fluorodeoxyglucose (FDG)-PET. The study population consisted of 33 patients with old myocardial infarction (27 men and 6 women; mean age, 62±8 years old). All patients underwent Ex/rest TF SPECT and glucose loading FDG-PET. Polar map images of Ex/rest TF were generated and divided into 24 segments for further analysis. We classified LV segments according to the exercise-rest perfusion scintigraphy. LV segments with less than 70% of the maximum TF activity on the exercise image were defined as stress-induced defects. Among these, the segments whose TF acitvity increased by 10% from exercise to rest images or exceeded 70% of the maximum uptake were defined as reversible (viable) defects. The remaining defects on the rest image were irreversible (non-viable) defect segments, and were considered for viability study on the basis of %WT. %WT was calculated according to the standard method: {(counts ES-counts ED)/ counts ED} x 100. A viable segment on gated SPECT was defined as a segment whose %WT exceeded the lower limit of the normal value (mean-SD). PET viability was defined as FDG uptake exceeding 50% of the maximum count. Among the 792 segments evaluated in the 33 patients studied, there were 689 PET viable segments. Of the 689 segments analyzed, 198 (29%) were identified as having defects on Ex images. Among these defects, 55 (8%) were reversible or partially reversible, as evidenced by rest images, and 143 (21%) were irreversible. Of the irreversible segments on Ex/rest images, 106 (15%) demonstrated no apparent WT by gated TF SPECT, whereas 37 (6%) segments with irreversible defects did have apparent WT. Overall, the sensitivity of Ex/rest TF perfusion imaging was 79%. Sensitivity was improved from 79% to 85% by combining %WT and perfusion data, but specificity was reduced from 70

  19. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Niboyet, Jean; Mundler, Olivier

    2007-01-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  20. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)]. E-mail: eric.guedj@ap-hm.fr; Taieb, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Cammilleri, Serge [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Lussato, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Laforte, Catherine de [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Niboyet, Jean [Unite d' Etude et de Traitement de la Douleur, Clinique La Phoceanne, Marseille (France); Mundler, Olivier [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)

    2007-02-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  1. Ordered synthesis and mobilization of glycogen in the perfused heart

    International Nuclear Information System (INIS)

    Brainard, J.R.; Hutson, J.Y.; Hoekenga, D.E.; Lenhoff, R.

    1989-01-01

    The molecular order of synthesis and mobilization of glycogen in the perfused heart was studied by 13 C NMR. By varying the glucose isotopomer ([1- 13 C]glucose or [2- 13 C]glucose) supplied to the heart, glycogen synthesized at different times during the perfusion was labeled at different carbon sites. Subsequently, the in situ mobilization of glycogen during ischemia was observed by detection of labeled lactate derived from glycolysis of the glucosyl monomers. When [1- 13 C]glucose was given initially in the perfusion and [2- 13 C]glucose was given second, [2- 13 C]lactate was detected first during ischemia and [3- 13 C]lactate second. This result, and the equivalent result when the glucose labels were given in the reverse order, demonstrates that glycogen synthesis and mobilization are ordered in the heart, where glycogen is found morphologically only as β particles. Previous studies of glycogen synthesis and mobilization in liver and adipocytes have suggested that the organization of β particles into α particles was partially responsible for ordered synthesis and mobilization. The observations reported here for cardiac glycogen suggest that another mechanism is responsible. In addition to examine the ordered synthesis and mobilization of cardiac glycogen, the authors have selectively monitored the NMR properties of 13 C-labeled glycogen synthesized early in the perfusion during further glycogen synthesis from a second, differently labeled substrate. During synthesis from the second labeled glucose monomer, the glycogen resonance from the first label decreased in integrated intensity and increased in line width. These results suggest either that there is significant isotopic exchange of glucosyl monomers in glycogen during net synthesis or that glucosyl residues incorporated into glycogen undergo motional restrictions as further glycogen synthesis occurs

  2. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  3. Quantification of myocardial perfusion SPECT for the assessment of coronary artery disease: should we apply scatter correction?

    International Nuclear Information System (INIS)

    Hambye, A.S.; Vervaet, A.; Dobbeleir, A.

    2002-01-01

    Compared to other non invasive testings for CAD diagnosis, myocardial perfusion imaging (MPI) is considered as a very sensitive method which accuracy is however often dimmed by a certain lack of specificity, especially in patients with a small heart. With gated SPECT MPI, use of end-diastolic instead of summed images has been presented as an interesting approach for increasing specificity. Since scatter correction is reported to improve image contrast, it might potentially constitute another way to ameliorate MPI accuracy. We aimed at comparing the value of both approaches, either separate or combined, for CAD diagnosis. Methods. Hundred patients addressed for gated 99m-Tc sestamibi SPECT MPI were prospectively included (Group A). Thirty-five had an end-systolic volume <30ml by QGS-analysis (Group B). All had a coronary angiogram within 3 months of the MPI. Four polar maps (non-corrected and scatter-corrected summed, and non-corrected and scatter-corrected end-diastolic) were created to quantify the extent (EXT) and severity (TDS) of the perfusion defects if any. ROC-curve analysis was applied to define the optimal thresholds of EXT and TDS separating non-CAD from CAD-patients, using a 50%-stenosis on coronary angiogram as cutoff for disease positivity. Results. Significant CAD was present in 86 patients (25 in Group B). In Group A, assessment of EXT and TDS of perfusion defects on scatter-corrected summed images demonstrated the highest accuracy (76% for EXT; sens: 77%; spec: 71%, and 74% for TDS, sens: 73%, spec: 79%). Accuracy of EXT and TDS calculated from the other data sets was slightly but not significantly lower, especially because of a lower sensitivity. As a comparison, visual analysis was 90% accurate for the diagnosis of CAD (sens: 94%, spec: 64%). In group B, overall results were worse mainly due to a decreased sensitivity, with accuracies ranging between 51 and 63%. Again scatter-corrected summed data were the most accurate (EXT: 60%, TDS: 63%, visual

  4. Optical techniques for perfusion monitoring of the gastric tube after esophagectomy: a review of technologies and thresholds.

    Science.gov (United States)

    Jansen, S M; de Bruin, D M; van Berge Henegouwen, M I; Strackee, S D; Veelo, D P; van Leeuwen, T G; Gisbertz, S S

    2018-04-26

    Anastomotic leakage is one of the most severe complications after esophageal resection with gastric tube reconstruction. Impaired perfusion of the gastric fundus is seen as the main contributing factor for this complication. Optical modalities show potential in recognizing compromised perfusion in real time, when ischemia is still reversible. This review provides an overview of optical techniques with the aim to evaluate the (1) quantitative measurement of change in perfusion in gastric tube reconstruction and (2) to test which parameters are the most predictive for anastomotic leakage.A Pubmed, MEDLINE, and Embase search was performed and articles on laser Doppler flowmetry (LDF), near-infrared spectroscopy (NIRS), laser speckle contrast imaging (LSCI), fluorescence imaging (FI), sidestream darkfield microscopy (SDF), and optical coherence tomography (OCT) regarding blood flow in gastric tube surgery were reviewed. Two independent reviewers critically appraised articles and extracted the data: Primary outcome was quantitative measure of perfusion change; secondary outcome was successful prediction of necrosis or anastomotic leakage by measured perfusion parameters.Thirty-three articles (including 973 patients and 73 animals) were selected for data extraction, quality assessment, and risk of bias (QUADAS-2). LDF, NIRS, LSCI, and FI were investigated in gastric tube surgery; all had a medium level of evidence. IDEAL stage ranges from 1 to 3. Most articles were found on LDF (n = 12), which is able to measure perfusion in arbitrary perfusion units with a significant lower amount in tissue with necrosis development and on FI (n = 12). With FI blood flow routes could be observed and flow was qualitative evaluated in rapid, slow, or low flow. NIRS uses mucosal oxygen saturation and hemoglobin concentration as perfusion parameters. With LSCI, a decrease of perfusion units is observed toward the gastric fundus intraoperatively. The perfusion units (LDF, LSCI), although

  5. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    Purpose: The aim of this study is to evaluate a possible correlation between areas of lung attenuation, found in minimum intensity projection (Min-IP) reconstruction images performed with high resolution computed tomography without contrast medium (HRCT), and areas of lung perfusion alteration, found in lung perfusion scintigraphy (LPS). Materials and methods: Two independent radiologists, unaware of LPS results, evaluated retrospectively a group of 113 patients affected by pulmonary hypertension (HP) of different aetiology. These have been examined in a period of two years in our centre both by spiral computed tomography (CT) with and without contrast-medium and by LPS. The final diagnosis was determined on clinical data, right heart catheterisation and contrast enhanced CT in angiographic phase (CTPA). We reconstructed the Min-IP images of lung parenchyma in all the cases both in HRCT without contrast-medium, and in contrast enhanced CT in angiographic phase (CTPA) in axial, sagittal and coronal planes. The obtained images were qualitatively graded into three categories of pulmonary attenuation: homogeneous, inhomogeneous with non-segmental patchy defects, inhomogeneous with segmental defects. The same criteria of classification were used also for LPS images. In the group of patients with chronic thromboembolic pulmonary hypertension (CTEPH) we also compared the number of areas of lung attenuation found in Min-IP images in HRCT without contrast-medium, and their exact localization, with not perfused areas in LPS. Gold standard for the diagnosis of pulmonary embolism was spiral contrast enhanced CT in angiographic phase (CTPA). Results: In all cases we found exact correspondence between the Min-IP images in HRCT with and without contras agent. The attenuation pattern seen on Min-IP images was concordant with those of LPS in 96 out of 113 patients (85%). In the remaining 17 cases (15%) it was discordant: in 12 cases inhomogeneous in Min-IP images (7 with non

  6. Perfusion MDCT enables early detection of therapeutic response to antiangiogenic therapy.

    Science.gov (United States)

    Sabir, Adeel; Schor-Bardach, Rachel; Wilcox, Carol J; Rahmanuddin, Syed; Atkins, Michael B; Kruskal, Jonathan B; Signoretti, Sabina; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2008-07-01

    The objective of our study was to determine whether perfusion CT can be used to detect early changes in therapeutic response to antiangiogenic therapy in an animal tumor model. Twenty-five rats implanted with R3230 mammary adenocarcinoma (diameter, 1.2-2.0 cm) randomly received 7.5 or 30 mg/kg of an antiangiogenic agent, sorafenib, by daily gavage for 4 (n = 4), 9 (n = 9), or 14 (n = 5) days. Seven untreated animals served as a control group. Perfusion MDCT was performed at days 0, 4, 9, and 14 with 0.4 mL of ioversol (350 mg/mL) and included four 5-mm slices covering the entire tumor volume. Changes in tumor growth were determined by volumetric analysis of CT data. Serial changes in tumor volume and blood flow were assessed and correlated with pathology findings. All control tumors grew larger (from 2.0 +/- 0.7 cm(3) at day 0 to 5.9 +/- 1.0 cm(3) at day 14), whereas all treated tumors shrank (from 2.5 +/- 1.1 to 2.1 +/- 1.0 cm(3)), with a statistically significant rate of growth or shrinkage in both groups (p histopathologic viability despite the fact that these tumors were shrinking in size from day 4 onward (day 4, 2.18 +/- 0.8 cm(3); day 9, 1.98 +/- 0.8 cm(3)). Perfusion MDCT can detect focal blood flow changes even when the tumor is shrinking, possibly indicating early reversal of tumor responsiveness to antiangiogenic therapy. Given that changes in tumor volume after antiangiogenic therapy do not necessarily correlate with true treatment response, physiologic imaging of tumor perfusion may be necessary.

  7. Myocardial perfusion SPECT in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery

    International Nuclear Information System (INIS)

    Padma, Subramanyam; Sundaram, Palaniswamy Shanmuga

    2014-01-01

    Pediatric myocardial perfusion imaging (MPI) is not a routine investigation in an Indian setting due to under referrals and logistic problems. However, MPI is a frequently performed and established modality of investigation in adults for the identification of myocardial ischemia and viability. We report myocardial perfusion scintigraphy in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery. Adenosine stress MPI revealed a large infarct involving anterior segment with moderate reversible ischemia of the lateral left ventricular segment. Coronary angiogram later confirmed left main coronary artery ostial occlusion with retrograde collateral supply from dilated right coronary artery

  8. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    International Nuclear Information System (INIS)

    Tutcu, Semra; Serter, Selim; Kaya, Yavuz; Kara, Eray; Nese, Nalan; Pekindil, Goekhan; Coskun, Teoman

    2010-01-01

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  9. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tutcu, Semra [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Serter, Selim, E-mail: serterselim@gmail.co [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Kaya, Yavuz; Kara, Eray [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Nese, Nalan [Department of Pathology, Celal Bayar University, School of Medicine, Manisa (Turkey); Pekindil, Goekhan [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Coskun, Teoman [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey)

    2010-08-15

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  10. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  11. Magnetic resonance perfusion imaging without contrast media

    International Nuclear Information System (INIS)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz; Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D.

    2010-01-01

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  12. Hepatic arterial perfusion increases in the early stage of severe acute pancreatitis patients: Evaluation by perfusion computed tomography

    International Nuclear Information System (INIS)

    Koyasu, Sho; Isoda, Hiroyoshi; Tsuji, Yoshihisa; Yamamoto, Hiroshi; Matsueda, Kazuhiro; Watanabe, Yuji; Chiba, Tsutomu; Togashi, Kaori

    2012-01-01

    Purpose: Although hepatic perfusion abnormalities have been reported in patients with acute pancreatitis, hepatic perfusion with severe acute pancreatitis (SAP) has not been quantitatively evaluated in humans. Therefore, we investigated hepatic perfusion in patients with SAP using perfusion CT. Materials and methods: Hepatic perfusion CT was performed in 67 patients with SAP within 3 days after symptom onset. The patients were diagnosed as having SAP according to the Atlanta criteria. Fifteen cases were established as a control group. Perfusion CT was obtained for 54 s beginning with a bolus injection of 40 ml of contrast agent (600–630 mgI/kg) at a flow rate of 4 ml/s. Perfusion data were analyzed by the dual-input maximum slope method to obtain hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP). Finally, we compared HAP and HPP in SAP patients with those in the control group, respectively. Results: Average HAP was significantly higher in SAP patients than in the control group (75.1 ± 38.0 vs. 38.2 ± 9.0 ml/min/100 ml; p < 0.001). There was no significant difference in average HPP between SAP patients and the control group (206.7 ± 54.9 vs. 204.4 ± 38.5 ml/min/100 ml; p = 0.92). Conclusion: Using quantitative analysis on perfusion CT, we first demonstrated an increase of HAP in the right hepatic lobe in SAP patients.

  13. The role of pharmacological stress Tc-99m sestamibi myocardial perfusion imaging in an Australian population

    International Nuclear Information System (INIS)

    Howarth, D.M.; Booker, J.A.; Tan, T.S.K.; Bellamy, G.R.; Hardy, D.B.; Howarth, G.C.

    2003-01-01

    This observational study was performed in order to assess the exercise-related incremental diagnostic accuracy of Tc-99m sestamibi myocardial perfusion imaging (MPI) in a hospital-based Australian population, and to assess the relative roles of exercise and pharmacological stress in myocardial perfusion imaging (MPI). Two hundred and eight adult patients who had both Tc-99m sestamibi myocardial perfusion imaging and coronary angiography within a median time of 16 weeks were studied. The diagnostic end-point was coronary artery lesions of ≥50% and >70% stenosis detected on angiography. Using receiver operating characteristic curve analysis, the overall diagnostic accuracy was calculated, as well as the comparative accuracies in patients who undertook various levels of exercise stress testing (n=130) and those who received pharmacological (dipyridamole) stress testing (n=78). The overall respective diagnostic accuracy of Tc-99m sestamibi MPI for the diagnosis of coronary artery disease (>70% stenosis) was 81% and 76% when using the diagnostic criterion of ≥50% stenosis. On direct comparison of perfusion defects with angiographic stenoses, the respective sensitivity and specificity for the detection of >70% stenosis in each coronary artery territory was 73% and 79%. Pharmacological MPI showed a significantly greater sensitivity for the detection of localised stenoses compared to the overall group who had exercise MPI performed. Consequently, exercise stress MPI showed significantly more false negative lesions compared to dipyridamole stress imaging (p<0.003). However, a large proportion of patients were unable to perform to adequate exercise levels in this patient sample. We conclude that Tc-99m sestamibi myocardial perfusion imaging is an accurate non-invasive test for the diagnosis of coronary artery disease. Where any doubt exists as to the patient's ability to achieve exercise levels at or above 85% of the predicted value for age and gender, pharmacological

  14. Arterial spin labelling MRI for detecting pseudocapsule defects and predicting renal capsule invasion in renal cell carcinoma.

    Science.gov (United States)

    Zhang, H; Wu, Y; Xue, W; Zuo, P; Oesingmann, N; Gan, Q; Huang, Z; Wu, M; Hu, F; Kuang, M; Song, B

    2017-11-01

    To evaluate prospectively the performance of combining morphological and arterial spin labelling (ASL) magnetic resonance imaging (MRI) for detecting pseudocapsule defects in renal cell carcinoma (RCC), and to predict renal capsule invasion confirmed histopathologically. Twenty consecutive patients with suspicious renal tumours underwent MRI. Renal ASL imaging was performed and renal blood flow was measured quantitatively. The diagnostic performance of T2-weighted images alone, and a combination of T2-weighted and ASL images for predicting renal capsule invasion were assessed. Twenty renal lesions were evaluated in 20 patients. All lesions were clear cell RCCs (ccRCCs) confirmed at post-surgical histopathology. Fifteen ccRCCs showed pseudocapsule defects on T2-weighted images, of which 12 cases showed existing blood flow in defect areas on perfusion images. To predict renal capsule invasion, the sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 71.4%, 86.7%, 100%, respectively, for T2-weighted images alone, and 92.3%, 100%, 100%, 87.5%, respectively, for the combination of T2-weighted and ASL images. ASL images can reflect the perfusion of pseudocapsule defects and as such, the combination of T2-weighted and ASL images produces promising diagnostic accuracy for predicting renal capsule invasion. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  16. Automatic assessment of cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Stegmann, Mikkel Bille; Larsson, Henrik B.W.

    2004-01-01

    In this paper, a method based on Active Appearance Models (AAM) is applied for automatic registration of myocardial perfusion MRI. A semi-quantitative perfusion assessment of the registered image sequences is presented. This includes the formation of perfusion maps for three parameters; maximum up...

  17. Thallium 201 Exercise Scintigraphy for Detection of Multivessel Coronary Artery Disease After Transmural Myocardial Infarction

    Science.gov (United States)

    Ahmadpour, Hedayatolah; Siegel, Michael E.; Colletti, Patrick; Haywood, L. Julian

    1984-01-01

    Fifty patients with prior transmural myocardial infarction were studied with cardiac catheterization, coronary angiography, and thallium 201 exercise perfusion scintigraphy. Obstructive coronary disease involved two or three vessels in 37 patients. The sensitivity of a positive electrocardiographic test during exercise for detecting multivessel coronary disease was only 40 percent (15/37), and the sensitivity of a reversible defect on 201Tl perfusion scintigraphy was 48 percent (18/37). The combination of exercise testing and 201Tl scintigraphy detected multivessel coronary disease in 75 percent (28/37) (P < .05). New perfusion defects occurred in 61 percent (13/21) of patients with inferior myocardial infarction and multivessel coronary disease whereas it occurred in only 35 percent (5/14) of patients with prior anterior infarction and multivessel coronary disease (P < .05). 201Tl exercise perfusion scintigraphy appears to be more sensitive for detecting significant multivessel coronary disease in the presence of previous inferior infarction compared with previous anterior infarction. Combined graded exercise testing and 201Tl perfusion scintigraphy can reliably detect the presence of significant multivessel coronary disease after transmural myocardial infarction. ImagesFigure 3 PMID:6512876

  18. Transformation between divacancy defects induced by an energy pulse in graphene.

    Science.gov (United States)

    Xia, Jun; Liu, XiaoYi; Zhou, Wei; Wang, FengChao; Wu, HengAn

    2016-07-08

    The mutual transformations among the four typical divacancy defects induced by a high-energy pulse were studied via molecular dynamics simulation. Our study revealed all six possible mutual transformations and found that defects transformed by absorbing energy to overcome the energy barrier with bonding, debonding, and bond rotations. The reversibility of defect transformations was also investigated by potential energy analysis. The energy difference was found to greatly influence the transformation reversibility. The direct transformation path was irreversible if the energy difference was too large. We also studied the correlation between the transformation probability and the input energy. It was found that the transformation probability had a local maxima at an optimal input energy. The introduction of defects and their structural evolutions are important for tailoring the exceptional properties and thereby performances of graphene-based devices, such as nanoporous membranes for the filtration and desalination of water.

  19. Diffusion and Perfusion Characteristics of MELAS (Mitochondrial Myopathy, Encephalopathy, Lactic Acidosis, and Stroke-Like Episode) in Thirteen Patients

    International Nuclear Information System (INIS)

    Kim, Ji Hye; Jeon, Tae Yeon; Eo, Hong; Yoo, So Young; Lim, Myung Kwan; Rha, Jung Ho; Shu, Chang Hae

    2011-01-01

    We analyzed the diffusion and perfusion characteristics of acute MELAS (mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episode) lesions in a large series to investigate the controversial changes of the apparent diffusion coefficient (ADC) that were reported in prior studies. We analyzed 44 newly appearing lesions during 28 stroke-like episodes in 13 patients with MELAS. We performed a visual assessment of the MR images including the ADC and perfusion maps, comparison of the ADC between the normal and abnormal areas, comparison of % ADC between the 44 MELAS lesions and the 30 acute ischemic infarcts. In addition, the patterns of evolution on follow-up MR images were analyzed. Decreased, increased, and normal ADCs were noted in 16 (36%), 16 (36%), and 12 (27%) lesions, respectively. The mean % ADC was 102 ± 40.9% in the MELAS and 64 ± 17.8% in the acute vascular infarcts (p < 0.001), while perfusion imaging demonstrated hyper-perfusion in six acute MELAS lesions. On follow-up images, resolution, progression, and tissue loss were noted in 10, 4, and 17 lesions, respectively. The cytotoxic edema gradually evolves following an acute stroke-like episode in patients with MELAS, and this may overlap with hyper-perfusion and vasogenic edema. The edematous swelling may be reversible or it may evolve to encephalomalacia, suggesting irreversible damage

  20. REM sleep enhancement and behavioral cataplexy following orexin (hypocretin)-II receptor antisense perfusion in the pontine reticular formation.

    Science.gov (United States)

    Thakkar, M M; Ramesh, V; Cape, E G; Winston, S; Strecker, R E; McCarley, R W

    1999-01-01

    Orexin (hypocretin)-containing neurons of the hypothalamus project to brainstem sites that are involved in the neural control of REM sleep, including the locus coeruleus, the dorsal raphe nucleus, the cholinergic zone of the mesopontine tegmentum, and the pontine reticular formation (PRF). Orexin knockout mice exhibit narcolepsy/cataplexy, and a mutant and defective gene for the orexin type II receptor is present in dogs with an inherited form of narcolepsy/cataplexy. However, the physiological systems mediating these effects have not been described. We reasoned that, since the effector neurons for the majority of REM sleep signs, including muscle atonia, were located in the PRF, this region was likely implicated in the production of these orexin-related abnormalities. To test this possibility, we used microdialysis perfusion of orexin type II receptor antisense in the PRF of rats. Ten to 24 hours after antisense perfusion, REM sleep increased two- to three-fold during both the light period (quiescent phase) and the dark period (active phase), and infrared video showed episodes of behavioral cataplexy. Moreover, preliminary data indicated no REM-related effects following perfusion with nonsense DNA, or when perfusion sites were outside the PRF. More work is needed to provide precise localization of the most effective site of orexin-induced inhibition of REM sleep phenomena.

  1. Role of perfusion SPECT in prediction and measurement of pulmonary complications after radiotherapy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Katherina P.; Khalil, Azza A.; Grau, Cai [Aarhus University Hospital, Department of Oncology, Aarhus C (Denmark); Kramer, Stine; Morsing, Anni [Aarhus University Hospital, Department of Nuclear Medicine and PET Centre, Aarhus C (Denmark)

    2015-07-15

    The purpose of the study was to evaluate the ability of baseline perfusion defect score (DS) on SPECT to predict the development of severe symptomatic radiation pneumonitis (RP) and to evaluate changes in perfusion on SPECT as a method of lung perfusion function assessment after curative radiotherapy (RT) for non-small-cell lung cancer (NSCLC). Patients with NSCLC undergoing curative RT were included prospectively. Perfusion SPECT/CT and global pulmonary function tests (PFT) were performed before RT and four times during follow-up. Functional activity on SPECT was measured using a semiquantitative perfusion DS. Pulmonary morbidity was graded by the National Cancer Institute's Common Terminology Criteria for Adverse Events version 4 for pneumonitis. Patients were divided into two groups according to the severity of RP. A total of 71 consecutive patients were included in the study. Baseline DS was associated with chronic obstructive pulmonary disease. A significant inverse correlation was found between baseline DS and forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide. Patients with severe RP had significantly higher baseline total lung DS (mean 5.43) than those with no or mild symptoms (mean DS 3.96, p < 0.01). PFT results were not different between these two groups. The odds ratio for total lung DS was 7.8 (95 % CI 1.9 - 31) demonstrating the ability of this parameter to predict severe RP. Adjustment for other potential confounders known to be associated with increased risk of RP was performed and did not change the odds ratio. The median follow-up time after RT was 8.4 months. The largest DS increase of 13.3 % was associated with severe RP at 3 months of follow-up (p < 0.01). The development of severe RP during follow-up was not associated with changes in PFT results. Perfusion SPECT is a valuable method for predicting severe RP and for assessing changes in regional functional perfusion after curative RT comparable with

  2. Ex-vivo machine perfusion for kidney preservation.

    Science.gov (United States)

    Hamar, Matyas; Selzner, Markus

    2018-06-01

    Machine perfusion is a novel strategy to decrease preservation injury, improve graft assessment, and increase organ acceptance for transplantation. This review summarizes the current advances in ex-vivo machine-based kidney preservation technologies over the last year. Ex-vivo perfusion technologies, such as hypothermic and normothermic machine perfusion and controlled oxygenated rewarming, have gained high interest in the field of organ preservation. Keeping kidney grafts functionally and metabolically active during the preservation period offers a unique chance for viability assessment, reconditioning, and organ repair. Normothermic ex-vivo kidney perfusion has been recently translated into clinical practice. Preclinical results suggest that prolonged warm perfusion appears superior than a brief end-ischemic reconditioning in terms of renal function and injury. An established standardized protocol for continuous warm perfusion is still not available for human grafts. Ex-vivo machine perfusion represents a superior organ preservation method over static cold storage. There is still an urgent need for the optimization of the perfusion fluid and machine technology and to identify the optimal indication in kidney transplantation. Recent research is focusing on graft assessment and therapeutic strategies.

  3. Noninvasive evaluation of regional myocardial perfusion in 112 patients using a mobile scintillation camera and intravenous nitrogen-13 labeled ammonia

    International Nuclear Information System (INIS)

    Walsh, W.F.; Harper, P.V.; Resnekov, L.; Fill, H.

    1976-01-01

    The short half-life positron emitter 13 N, as labeled ammonia ( 13 NH 4 + ), was evaluated as a myocardial imaging agent. Regional myocardial uptake of 13 NH 4 correlated with the distribution of labeled microspheres in experimental myocardial infarction. Using intravenous 13 NH 4 + , myocardial scintigraphy was performed in 85 cardiac patients and 27 normal subjects. Ninety-five scintigrams were suitable for analysis. Eighteen of 24 normal subjects had homogeneous myocardial images; six had inhomogeneous images attributable to early technical problems. Perfusion defects were observed in the scintigrams of 82% (57/65) of patients with coronary artery disease, being most common in patients with myocardial infarction (27/28). Six sequential studies showed changes in perfusion consistent with the clinical course of each patient. Scintigraphic abnormalities were also observed in 4/6 patients with valvular heart disease. 13 NH 4 + myocardial scintigraphy is a valid and sensitive method of assessing regional myocardial perfusion and is especially useful for sequential imaging at short intervals

  4. Assessment of myocardial viability by exercise stress myocardial tomography with 201Tl

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1992-01-01

    Exercise stress (Ex) and redistribution (RD) myocardial tomography with Tl-201 has been widely used for evaluating myocardial viability. But recent studies have demonstrated that reinjection (ReI) study following RD study is necessary for detecting reversible ischemic myocardium. On the other hand, decreased myocardial washout of Tl-201 after Ex is an indicator of myocardial ischemia. So we have studied the usefulness of myocardial Tl-201 washout rate (WOR) for the evaluation of myocardial viability by comparing it with ReI images. Ex and RD myocardial tomographies were obtained immediately after Ex and 3 hours later. After RD study a small amount of Tl-201 was injected and ReI imaging was repeated. We studied 64 myocardial segments (in 58 patients with coronary artery disease) in which Ex-induced perfusion defects persisted in RD images. According to the changes of perfusion defects between Ex, RD and ReI images, they were classified into 3 types: Type I; perfusion defect on the RD image was identical to ReI image (75%). Type I was divided into 2 subgroups whether perfusion defect at Ex was unchanged (Ia, 42%) or improved (Ib, 33%) on the RD image. Type II; perfusion defect at Ex was reduced on the RD image and it improved furthermore at ReI image (17%). Type III; perfusion defect was the same at Ex and RD but it was reduced on the ReI image (8%). WOR less than 30% was defined as abnormal when Ex heart rate exceeded 120 bpm and lung-myocardial Tl-201 uptake ratio was less than 0.45. The differentiation between Type Ia and Type III is of great importance. History of myocardial infarction, effort angina and Ex induced ST depression could not differentiate these 2 groups. WOR abnormality was observed in all of Type III, but WOR was normal in Type Ia. In conclusion, WOR abnormality in Ex-RD myocardial imaging is useful for evaluating myocardial viability. ReI imaging is necessary for the precise evaluation of viable muscle mass and for inadequate Ex. (author)

  5. A model that accounts for the interdependence of extent and severity in the automatic evaluation of myocardial defects

    DEFF Research Database (Denmark)

    El-Ali, Henrik Hussein; Palmer, John; Edenbrandt, Lars

    2006-01-01

    The extent and severity are two important parameters when describing a regional defect in myocardial single-photon emission computed tomography (SPECT) perfusion imaging. Intuitively, these two parameters should be independent of each other, but we have shown in a previous study that there is an ...

  6. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

    Science.gov (United States)

    Armstrong, Ian S; Saint, Kimberley J; Tonge, Christine M; Arumugam, Parthiban

    2017-04-01

    There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.

  7. Perfusion based cell culture chips

    DEFF Research Database (Denmark)

    Heiskanen, Arto; Emnéus, Jenny; Dufva, Martin

    2010-01-01

    Performing cell culture in miniaturized perfusion chambers gives possibilities to experiment with cells under near in vivo like conditions. In contrast to traditional batch cultures, miniaturized perfusion systems provide precise control of medium composition, long term unattended cultures...... and tissue like structuring of the cultures. However, as this chapter illustrates, many issues remain to be identified regarding perfusion cell culture such as design, material choice and how to use these systems before they will be widespread amongst biomedical researchers....

  8. Thallium imaging in management of post-revascularization patients

    International Nuclear Information System (INIS)

    Alazraki, N.; Krawczynska, E.

    1996-01-01

    The role of myocardial perfusion imaging in the evaluation of post revascularization patients has not been well defined. Published data with special emphasis on the results from the Emory Angioplasty versus Surgery Trial (EAST) indicate that the frequency of adverse cardiac events (death, MI, repeat revascularization) following PTCA or CABG is equal in symptomatic and asymptomatic patients with ischemic thallium defects. Current American Heart Association Guidelines recommend radionuclide studies only in symptomatic patients. Recently reported data support the need for non invasive testing in asymptomatic as well as symptomatic patients at 1 year postrevascularization. Prognostic variables including transient and permanent left ventricular dilatation and thallium lung uptake in addition to stress perfusion defect reversibility on myocardial thallium SPECT scans are important prognostic indicators in post revascularization patients

  9. Developing a Benchmarking Process in Perfusion: A Report of the Perfusion Downunder Collaboration

    Science.gov (United States)

    Baker, Robert A.; Newland, Richard F.; Fenton, Carmel; McDonald, Michael; Willcox, Timothy W.; Merry, Alan F.

    2012-01-01

    Abstract: Improving and understanding clinical practice is an appropriate goal for the perfusion community. The Perfusion Downunder Collaboration has established a multi-center perfusion focused database aimed at achieving these goals through the development of quantitative quality indicators for clinical improvement through benchmarking. Data were collected using the Perfusion Downunder Collaboration database from procedures performed in eight Australian and New Zealand cardiac centers between March 2007 and February 2011. At the Perfusion Downunder Meeting in 2010, it was agreed by consensus, to report quality indicators (QI) for glucose level, arterial outlet temperature, and pCO2 management during cardiopulmonary bypass. The values chosen for each QI were: blood glucose ≥4 mmol/L and ≤10 mmol/L; arterial outlet temperature ≤37°C; and arterial blood gas pCO2 ≥ 35 and ≤45 mmHg. The QI data were used to derive benchmarks using the Achievable Benchmark of Care (ABC™) methodology to identify the incidence of QIs at the best performing centers. Five thousand four hundred and sixty-five procedures were evaluated to derive QI and benchmark data. The incidence of the blood glucose QI ranged from 37–96% of procedures, with a benchmark value of 90%. The arterial outlet temperature QI occurred in 16–98% of procedures with the benchmark of 94%; while the arterial pCO2 QI occurred in 21–91%, with the benchmark value of 80%. We have derived QIs and benchmark calculations for the management of several key aspects of cardiopulmonary bypass to provide a platform for improving the quality of perfusion practice. PMID:22730861

  10. Induced Pluripotent Stem Cell Models of Progranulin-Deficient Frontotemporal Dementia Uncover Specific Reversible Neuronal Defects

    Directory of Open Access Journals (Sweden)

    Sandra Almeida

    2012-10-01

    Full Text Available The pathogenic mechanisms of frontotemporal dementia (FTD remain poorly understood. Here we generated multiple induced pluripotent stem cell lines from a control subject, a patient with sporadic FTD, and an FTD patient with a novel heterozygous GRN mutation (progranulin [PGRN] S116X. In neurons and microglia differentiated from PGRN S116X induced pluripotent stem cells, the levels of intracellular and secreted PGRN were reduced, establishing patient-specific cellular models of PGRN haploinsufficiency. Through a systematic screen of inducers of cellular stress, we found that PGRN S116X neurons, but not sporadic FTD neurons, exhibited increased sensitivity to staurosporine and other kinase inhibitors. Moreover, the serine/threonine kinase S6K2, a component of the phosphatidylinositol 3-kinase and mitogen-activated protein kinase pathways, was specifically downregulated in PGRN S116X neurons. Both increased sensitivity to kinase inhibitors and reduced S6K2 were rescued by PGRN expression. Our findings identify cell-autonomous, reversible defects in patient neurons with PGRN deficiency, and provide a compelling model for studying PGRN-dependent pathogenic mechanisms and testing potential therapies.

  11. Non-contrast MRI perfusion angiosome in diabetic feet

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jie [Cardiovascular Imaging Lab, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Hastings, Mary K.; Mueller, Michael J. [Washington University School of Medicine, The Program in Physical Therapy, St. Louis, MO (United States); Muccigross, David; Hildebolt, Charles F. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Fan, Zhaoyang [Cedars-Sinai Medical Center, Biomedical Imaging Research Institute, Los Angeles, CA (United States); Gao, Fabao [West China Hospital, Sichuan University, Department of Radiology, Chengdu (China); Curci, John [Washington University School of Medicine, The Department of Surgery, St. Louis, MO (United States)

    2015-01-15

    The purpose of this study is to develop a non-contrast magnetic resonance imaging (MRI) approach to evaluate skeletal muscle perfusion in the diabetic foot based on the concept of angiosomes of the foot. Five healthy volunteers and five participants with diabetes (HbA1c = 7.2 ± 1.8 %) without a history of peripheral artery disease were examined. The non-contrast perfusion measurements were performed during a toe flexion challenge. Absolute perfusion maps were created and two regions (medial and lateral) on the maps were segmented based on angiosomes. Regional difference in the perfusion of foot muscle was readily visualized in the MRI perfusion angiosomes during the challenge. In the participants with diabetes, the perfusion during toe flexion challenge was significantly lower than in healthy volunteers (P < 0.01). The average perfusion for the medial plantar region of the right foot was lower in subjects with diabetes (38 ± 9 ml/min/100 g) than in healthy subjects (93 ± 33 ml/min/100 g). Non-contrast MRI perfusion angiosome maps demonstrate the feasibility of determining regional perfusion in foot muscles during toe challenge and may facilitate evaluation of muscle perfusion in diabetic feet. (orig.)

  12. Non-contrast MRI perfusion angiosome in diabetic feet

    International Nuclear Information System (INIS)

    Zheng, Jie; Hastings, Mary K.; Mueller, Michael J.; Muccigross, David; Hildebolt, Charles F.; Fan, Zhaoyang; Gao, Fabao; Curci, John

    2015-01-01

    The purpose of this study is to develop a non-contrast magnetic resonance imaging (MRI) approach to evaluate skeletal muscle perfusion in the diabetic foot based on the concept of angiosomes of the foot. Five healthy volunteers and five participants with diabetes (HbA1c = 7.2 ± 1.8 %) without a history of peripheral artery disease were examined. The non-contrast perfusion measurements were performed during a toe flexion challenge. Absolute perfusion maps were created and two regions (medial and lateral) on the maps were segmented based on angiosomes. Regional difference in the perfusion of foot muscle was readily visualized in the MRI perfusion angiosomes during the challenge. In the participants with diabetes, the perfusion during toe flexion challenge was significantly lower than in healthy volunteers (P < 0.01). The average perfusion for the medial plantar region of the right foot was lower in subjects with diabetes (38 ± 9 ml/min/100 g) than in healthy subjects (93 ± 33 ml/min/100 g). Non-contrast MRI perfusion angiosome maps demonstrate the feasibility of determining regional perfusion in foot muscles during toe challenge and may facilitate evaluation of muscle perfusion in diabetic feet. (orig.)

  13. Exercise thallium-201 imaging in complete left bundle branch block and the prevalence of septal perfusion defects

    International Nuclear Information System (INIS)

    Jazmati, B.; Sadaniantz, A.; Emaus, S.P.; Heller, G.V.

    1991-01-01

    To determine the prevalence of septal defects in a generalized referral population, the records of 93 consecutive patients with complete left bundle branch block (BBB) who underwent symptom-limited treadmill exercise testing with thallium-201 myocardial imaging over a 3-year period were reviewed. Segmental analysis of the planar thallium-201 images was performed in a blinded fashion with agreement by consensus. Computerized quantitative analysis of the images also was independently performed, and was correlated with the visual interpretations. Forty-seven patients (51%) had normal images, and 46 (49%) had defects of greater than or equal to 2 segments. In the abnormal studies, only 13 patients (14% of the total population) had septal defects, while a much higher number of patients, 33 (39%), had inferior or apical defects, or both. Coronary angiography was performed in 6 patients with septal defects: Significant narrowing of the left anterior descending coronary artery was found in 4 patients, a narrowed right coronary artery was found in 1, and normal coronary arteries were seen in the other patient. In conclusion, whereas previous studies have suggested a high percentage of false-positive septal defects in patients with left BBB, this study demonstrates a low prevalence (14%) of septal defects in a large population of unselected patients presenting for exercise thallium-201 imaging. Therefore, exercise thallium-201 imaging remains a useful procedure for evaluating patients with complete left BBB

  14. Dual-energy perfusion-CT of pancreatic adenocarcinoma

    International Nuclear Information System (INIS)

    Klauß, M.; Stiller, W.; Pahn, G.; Fritz, F.; Kieser, M.; Werner, J.; Kauczor, H.U.; Grenacher, L.

    2013-01-01

    Purpose: To evaluate the feasibility of dual-energy CT (DECT)-perfusion of pancreatic carcinomas for assessing the differences in perfusion, permeability and blood volume of healthy pancreatic tissue and histopathologically confirmed solid pancreatic carcinoma. Materials and methods: 24 patients with histologically proven pancreatic carcinoma were examined prospectively with a 64-slice dual source CT using a dynamic sequence of 34 dual-energy (DE) acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). 80 kV p , 140 kV p , and weighted average (linearly blended M0.3) 120 kV p -equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (Body-PCT, Siemens Medical Solutions, Erlangen, Germany) for estimating perfusion, permeability, and blood volume values. Color-coded parameter maps were generated. Results: In all 24 patients dual-energy CT-perfusion was. All carcinomas could be identified in the color-coded perfusion maps. Calculated perfusion, permeability and blood volume values were significantly lower in pancreatic carcinomas compared to healthy pancreatic tissue. Weighted average 120 kV p -equivalent perfusion-, permeability- and blood volume-values determined from DE image data were 0.27 ± 0.04 min −1 vs. 0.91 ± 0.04 min −1 (p −1 vs. 0.67 ± 0.05 *0.5 min −1 (p = 0.06) and 0.49 ± 0.07 min −1 vs. 1.28 ± 0.11 min −1 (p p the standard deviations of the kV p 120 kV p -equivalent values were manifestly smaller. Conclusion: Dual-energy CT-perfusion of the pancreas is feasible. The use of DECT improves the accuracy of CT-perfusion of the pancreas by fully exploiting the advantages of enhanced iodine contrast at 80 kV p in combination with the noise reduction at 140 kV p . Therefore using dual-energy perfusion data could improve the delineation of pancreatic carcinomas

  15. Myocardial perfusion assessment by dual-energy computed tomography in patients with intermediate to high likelihood of coronary artery disease

    International Nuclear Information System (INIS)

    De Zam, M.C.; Capunay, C.; Rodriguez Granillo, G.A.; Deviggiano, A.; Campisi, R.; Munain, M. López de; Vallejos, J.; Carrascosa, P.M.

    2015-01-01

    Objectives. We sought to explore the feasibility and diagnostic performance of dual-energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD), and to assess the impact of beam hardening artifacts (HAE). Methods. The present prospective study involved patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT). Twenty patients were included in the study protocol, and scanned using DECT imaging (n = 20). The same pharmacological stress was used for DECT and SPECT scans. Results. A total of 680 left ventricular segments were evaluated by DECT and SPECT. The contrast to noise ratio was 8.8±2.9. The diagnostic performance of DECT was very good in identifying perfusion defects [area under ROC curve (AUC) of DECT 0.90 (0.86-0.94)] compared with SPECT, and remained unaffected when including only segments affected by beam hardening artifacts (BHA) [AUC= DECT 0.90 (0.84-0.96)]. Conclusions. In this pilot investigation, myocardial perfusion assessment by DECT imaging in patients with intermediate to high likelihood of CAD was feasible and remained unaffected by the presence of BHA. (authors) [es

  16. In-vivo quantitative evaluation of perfusion zones and perfusion gradient in the deep inferior epigastric artery perforator flap

    Science.gov (United States)

    Saint-Cyr, Michel; Lakhiani, Chrisovalantis; Cheng, Angela; Mangum, Michael; Liang, Jinyang; Teotia, Sumeet; Livingston, Edward H.; Zuzak, Karel J.

    2013-03-01

    The selection of well-vascularized tissue during DIEP flap harvest remains controversial. While several studies have elucidated cross-midline perfusion, further characterization of perfusion to the ipsilateral hemiabdomen is necessary for minimizing rates of fat necrosis or partial fat necrosis in bilateral DIEP flaps. Eighteen patients (29 flaps) underwent DIEP flap harvest using a prospectively designed protocol. Perforators were marked and imaged with a novel system for quantitatively measuring tissue oxygenation, the Digital Light Hyperspectral Imager. Images were then analyzed to determine if perforator selection influenced ipsilateral flap perfusion. Flaps based on a single lateral row perforator (SLRP) were found to have a higher level of hemoglobin oxygenation in Zone I (mean %HbO2 = 76.1) compared to single medial row perforator (SMRP) flaps (%HbO2 = 71.6). Perfusion of Zone III relative to Zone I was similar between SLRP and SMRP flaps (97.4% vs. 97.9%, respectively). These differences were not statistically significant (p>0.05). Perfusion to the lateral edge of the flap was slightly greater for SLRP flaps compared SMRP flaps (92.1% vs. 89.5%, respectively). SMRP flaps had superior perfusion travelling inferiorly compared to SLRP flaps (88.8% vs. 83.9%, respectively). Overall, it was observed that flaps were better perfused in the lateral direction than inferiorly. Significant differences in perfusion gradients directed inferiorly or laterally were observed, and perforator selection influenced perfusion in the most distal or inferior aspects of the flap. This suggests broader clinical implications for flap design that merit further investigation.

  17. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    International Nuclear Information System (INIS)

    Bauman, Grzegorz; Puderbach, Michael; Heimann, Tobias; Kopp-Schneider, Annette; Fritzsching, Eva; Mall, Marcus A.; Eichinger, Monika

    2013-01-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis

  18. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, Grzegorz, E-mail: g.bauman@dkfz.de [German Cancer Research Center, Division of Medical Physics in Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Puderbach, Michael, E-mail: m.puderbach@dkfz.de [Chest Clinics at the University of Heidelberg, Clinics for Interventional and Diagnostic Radiology, Amalienstr. 5, 69126 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); Heimann, Tobias, E-mail: t.heimann@dkfz.de [German Cancer Research Center, Division of Medical and Biological Informatics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Kopp-Schneider, Annette, E-mail: kopp@dkfz.de [German Cancer Research Center, Division of Biostatistics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Fritzsching, Eva, E-mail: eva.fritzsching@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Mall, Marcus A., E-mail: marcus.mall@med.uni-heidelberg.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Eichinger, Monika, E-mail: m.eichinger@dkfz.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); German Cancer Research Center, Division of Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany)

    2013-12-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis.

  19. Fatty acid metabolism in symptomatic patients with mitral valve prolapse but without coronary artery disease - comparison with 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Voth, E.; Schicha, H.; Neumann, P.; Emrich, D.; Tebbe, U.

    1987-01-01

    Using 123 I-ω-heptadecanoic acid (HDA) and 201 Tl, respectively, myocardial fatty acid metabolism and perfusion were studied in 51 symptomatic patients with mitral valve prolapse (MVP) as diagnosed by ventriculography, and no evidence of coronary artery disease. Twelve subjects with normal coronary arteries and normal ventriculogram served as a control group for the evaluation of elimination kinetics of HDA. In the control group, the mean elimination half-life was 26.1±3.6 min, whereas the patients with MVP had a mean value of 25.0±6.4 min. In patients with MVP, a high incidence concerning abnormalities of accumulation and/or elimination of HDA occurred, namely accumulation defects in 31% and both prolonged and shortened elimination half-lives in 16% and 29%, respectively. Myocardial perfusion scintigraphy using 201 Tl showed abnormalities in 76%. Correlations were found between decreased uptake of HDA and prolonged elimination half-life as well as defects by 201 Tl, presumably due to ischemia based on small-vessel disease or abnormalities of cellular metabolism. (orig.) [de

  20. Placental perfusion - a human alternative

    DEFF Research Database (Denmark)

    Mose, Tina; Knudsen, Lisbeth E

    2006-01-01

    Foetal exposures to environmental and medicinal products have impact on the growth of the foetus (e.g. cigarette smoke) and development of organs (e.g. methylmercury and Thalidomide). Perfusion studies of the human term placenta enable investigation of placental transport of chemical substances...... between the mother and foetus. Dual perfusion of a single cotyledon in the human placenta can contribute to a better understanding of the placental barrier, transport rate and mechanisms of different substances and placental metabolism. The perfusion system has recently been established in Copenhagen...

  1. Cytoskeletal defects in Bmpr2-associated pulmonary arterial hypertension.

    Science.gov (United States)

    Johnson, Jennifer A; Hemnes, Anna R; Perrien, Daniel S; Schuster, Manfred; Robinson, Linda J; Gladson, Santhi; Loibner, Hans; Bai, Susan; Blackwell, Tom R; Tada, Yuji; Harral, Julie W; Talati, Megha; Lane, Kirk B; Fagan, Karen A; West, James

    2012-03-01

    The heritable form of pulmonary arterial hypertension (PAH) is typically caused by a mutation in bone morphogenic protein receptor type 2 (BMPR2), and mice expressing Bmpr2 mutations develop PAH with features similar to human disease. BMPR2 is known to interact with the cytoskeleton, and human array studies in PAH patients confirm alterations in cytoskeletal pathways. The goal of this study was to evaluate cytoskeletal defects in BMPR2-associated PAH. Expression arrays on our Bmpr2 mutant mouse lungs revealed cytoskeletal defects as a prominent molecular consequence of universal expression of a Bmpr2 mutation (Rosa26-Bmpr2(R899X)). Pulmonary microvascular endothelial cells cultured from these mice have histological and functional cytoskeletal defects. Stable transfection of different BMPR2 mutations into pulmonary microvascular endothelial cells revealed that cytoskeletal defects are common to multiple BMPR2 mutations and are associated with activation of the Rho GTPase, Rac1. Rac1 defects are corrected in cell culture and in vivo through administration of exogenous recombinant human angiotensin-converting enzyme 2 (rhACE2). rhACE2 reverses 77% of gene expression changes in Rosa26-Bmpr2(R899X) transgenic mice, in particular, correcting defects in cytoskeletal function. Administration of rhACE2 to Rosa26-Bmpr2(R899X) mice with established PAH normalizes pulmonary pressures. Together, these findings suggest that cytoskeletal function is central to the development of BMPR2-associated PAH and that intervention against cytoskeletal defects may reverse established disease.

  2. The Groningen hypothermic liver perfusion pump : Functional evaluation of a new machine perfusion system

    NARCIS (Netherlands)

    van der Plaats, A.; Maathuis, M. H. J.; Hart, N. A. 't; Bellekom, A. A.; Hofker, H. S.; van der Houwen, E. B.; Verkerke, G. J.; Leuvenink, H. G. D.; Verdonck, P.; Ploeg, R. J.; Rakhorst, G.

    2006-01-01

    To improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion,

  3. Vicarious audiovisual learning in perfusion education.

    Science.gov (United States)

    Rath, Thomas E; Holt, David W

    2010-12-01

    Perfusion technology is a mechanical and visual science traditionally taught with didactic instruction combined with clinical experience. It is difficult to provide perfusion students the opportunity to experience difficult clinical situations, set up complex perfusion equipment, or observe corrective measures taken during catastrophic events because of patient safety concerns. Although high fidelity simulators offer exciting opportunities for future perfusion training, we explore the use of a less costly low fidelity form of simulation instruction, vicarious audiovisual learning. Two low fidelity modes of instruction; description with text and a vicarious, first person audiovisual production depicting the same content were compared. Students (n = 37) sampled from five North American perfusion schools were prospectively randomized to one of two online learning modules, text or video.These modules described the setup and operation of the MAQUET ROTAFLOW stand-alone centrifugal console and pump. Using a 10 question multiple-choice test, students were assessed immediately after viewing the module (test #1) and then again 2 weeks later (test #2) to determine cognition and recall of the module content. In addition, students completed a questionnaire assessing the learning preferences of today's perfusion student. Mean test scores from test #1 for video learners (n = 18) were significantly higher (88.89%) than for text learners (n = 19) (74.74%), (p audiovisual learning modules may be an efficacious, low cost means of delivering perfusion training on subjects such as equipment setup and operation. Video learning appears to improve cognition and retention of learned content and may play an important role in how we teach perfusion in the future, as simulation technology becomes more prevalent.

  4. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  5. Unsuccessful lung scan due to major right-to-left shunt through a sinus venosus septal defect

    International Nuclear Information System (INIS)

    Brendel, A.J.; Larnaudie, B.; Lambert, B.; Leccia, F.; Barat, J.L.; Ducassou, D.; Fontan, F.

    1985-01-01

    In a patient with a prior history of cerebral abscess and cerebral ischemia, an unsuccessful perfusion lung scan led to a radionuclide angiocardiogram using an arm vein injection. This showed a total right-to-left (R-L) shunt from the superior vena cava (SVC) to the left atrium. Repeat radionuclide study, through a leg vein, demonstrated a moderate R-L shunt and an interpretable lung scan could be obtained. Catheterization and contrast cineangiogram did not provide the exact diagnosis, the preoperative conclusion being anomalous drainage of the SVC into the left atrium, with atrial septal defect (ASD) and partial anomalous pulmonary venous connection to the SVC. The operative diagnosis was high atrial (sinus venosus) septal defect. This example of major but clinically unsuspected R-L shunt emphasizes the value of performing a perfusion lung scan, preferably in conjunction with radionuclide angiocardiography in patients with a prior history of unexplained cerebral abscess or systemic ischemia. Implications of the site of an ASD on quantitation of L-R shunts by radionuclide methods are also discussed

  6. Pattern-reversal electroretinograms in unilateral glaucoma.

    Science.gov (United States)

    Wanger, P; Persson, H E

    1983-06-01

    Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means from glaucomatous and opposite eyes was statistically significant. No differences were observed in flash ERGs or OPs. The histopathologic correlate to the visual field defects in glaucoma is retinal ganglion cell degeneration. The present electrophysiologic findings support the view, based on results from animal experiments, that the pattern-reversal ERG reflects ganglion cell activity.

  7. Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery

    Directory of Open Access Journals (Sweden)

    Schnackenburg Bernhard

    2010-05-01

    Full Text Available Abstract Background Adenosine first pass perfusion cardiovascular magnetic resonance (CMR yields excellent results for the detection of significant coronary artery disease (CAD. In patients with coronary artery bypass grafts (CABG the kinetics of a contrast bolus may by altered only due to different distances through the bypass grafts compared to native vessels, thereby possibly imitating a perfusion defect. The aim of the study was to evaluate semiquantitative perfusion parameters in order to assess possible differences in epicardial contrast kinetics in areas supplied by native coronaries and CABG, both without significant stenosis. Methods Twenty patients with invasive exclusion of significant CAD (control group and 38 patients with CABG without angiographically significant (≥50% stenosis in unbypassed coronaries or grafts were retrospectively included in the study. They underwent adenosine first pass (0.05 mmol/kg Gd-DTPA perfusion (3 short axis views/heart beat and late gadolinium enhancement (LGE imaging 1 day before invasive coronary angiography. Areas perfused by native coronaries and/or the different bypasses were identified in X-ray angiography using the 16 segment model. In each of these areas upslope and maximal signal intensity (SImax relative to the left ventricular parameters, time to 50% maximal signal intensity (TSI50%max and time to maximal signal intensity (TSImax were calculated. Results In areas perfused by coronary arteries with bypasses compared to native coronaries relative upslope and relative SImax did not show a significant difference. TSI50%max and TSImax in native coronaries and bypasses were 7.2s ± 1.9s vs. 7.5s ± 1.9s (p max resulted in a significant (p Conclusion Adenosine perfusion CMR in patients post CABG may be associated with a short delay in contrast arrival. However, once the contrast is in the myocardium there is similar wash-in kinetics and peak enhancement. Therefore, since the delay is only short

  8. Clinical evaluation of brain perfusion scintigraphy using N-isopropyl-p-[123I]-iodoamphetamine

    International Nuclear Information System (INIS)

    Shimbo, Shin-ichiro; Yamamoto, Itsuo; Yagi, Kenji; Misaki, Takashi; Dokoh, Shigeharu

    1989-01-01

    The present study includes 16 patients with symptoms related to cerebrovascular insufficiency, who were randomly selected from out outpatient clinic of internal medicine. Single photon emission computed tomography (SPECT) with 111∼185 MBq (3∼5 mCi) of N-isopropyl-p-[ 123 I]-iodoamphetamine (IMP) was performed 20 min and 3 hr after intravenous administration of the tracer, and compared to the image of conventional X-ray computed tomography (X-CT). Out of twelve cases with significant findings in X-CT, 9 showed corresponding changes in perfusion in SPECT with IMP, and the remaining 3 did not. In a patient with cerebral infarction, SPECT revealed a perfusion defect whereas her X-CT was negative, thereby proved to be useful in determining the focus of clinically suspected stroke. There were some other cases in which findings in SPECT and X-CT were discordant. From our series of scans, SPECT seemed useful in detecting responsible sites of neurological deficits in early and, occasionally, remote phases of cerebrovascular accidents, while X-CT appeared superior in finding smaller lesions. (author)

  9. Regional distribution of ventilation-perfusion ratio in patients with interstitial pneumonia using Kr-81m

    International Nuclear Information System (INIS)

    Sekine, Hiroshi; Kawakami, Kenji; Shimada, Takao

    1983-01-01

    In order to know the pathophysiological change of interstitial pneumonia, it is important to detect the morphological change of vascular and air way systems in the lung. The study group consisted of 12 patients of interstitial pneumonia including IIP, PSS, RA, sarcoidosis, and hypersensitive pneumonia. The Kr-81m bolus inhalation from 3 different lung volumes were analyzed to detect regional ventilation abnormalities. The regional distribution of ventilation-perfusion ratio (V/Q) in the lung was obtained from the continuous inhalation and infusion Kr-81 m. In 7 patients, regional distribution of V/Q was also measured at rest and during exercise. In advanced stage of interstitial pneumonia, radioactivity in lower lung fields was decreased in bolus inhalation from TLC-400 ml lung volume, and present in lower lung in bolus inhalation from RV level. These findings are representing air way rigidity especially in lower lung fields. However, in early stage or reversible cases, it is difficult to detect the abnormal distribution of radioactivity in lung, in spite of decreased PO 2 . So it seems impossible to screen early stage or reversible cases of interstitial pneumonia by bolus inhalation method alone. At rest for normal subjects in the upright position, the apical zone had a high V/Q, but in the lower parts two third of V/Q distribution was relatively homogeneous. During exercise at 50W, the distribution became more uniform. In most cases of the disease, weak exercise (less than 40W) produced the same uniform V/Q distribution. It should be noted that in the disease not only was perfusion in upper lung fields increased, but that perfusion of lower lung fields was reduced. So late in the cource of extension of the disease, pulmonary vascular bed in the lower lung fields is restricted.(J.P.N.)

  10. Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Achenbach, Stephan; Marwan, Mohamed; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2010-07-15

    To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). Thirty-eight patients with non-ST segment elevation myocardial infarction (NSTEMI) or unstable angina (UA) and scheduled for percutaneous coronary intervention underwent dual-source CT immediately before catheterisation. CT images were analysed for the presence of any PD by using a 17-segment model. Results were compared with peak cardiac troponin-I (cTnI) and angiography findings. PD were seen in 21 of the 24 patients with NSTEMI (median peak cTnI level 7.07 ng/mL; range 0.72-37.07 ng/mL) and in 2 of 14 patients with UA. PD corresponded with the territory of the infarct-related artery in 20 out of 22 patients. In a patient-based analysis, sensitivity, specificity, negative and positive predictive values of any PD for predicting NSTEMI were 88%, 86%, 80% and 91%. Per culprit artery, the respective values were 86%, 75%, 80% and 83%. In patients with non-ST segment elevation ACS, first-pass myocardial PD in contrast-enhanced MDCT correlate closely with the presence of myocardial necrosis, as determined by increases in cTnI levels. (orig.)

  11. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Dowdle, S.C.; Human, D.G.; Mann, M.D. (Univ. of Cape Town (South Africa))

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  12. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    International Nuclear Information System (INIS)

    Dowdle, S.C.; Human, D.G.; Mann, M.D.

    1990-01-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis

  13. Effect of maintenance oral theophylline on dipyridamole-thallium-201 myocardial imaging using SPECT and dipyridamole-induced hemodynamic changes

    International Nuclear Information System (INIS)

    Daley, P.J.; Mahn, T.H.; Zielonka, J.S.; Krubsack, A.J.; Akhtar, R.; Bamrah, V.S.

    1988-01-01

    To evaluate the effect of maintenance oral theophylline therapy on the diagnostic efficacy of dipyridamole-thallium-201 single photon emission computed tomography (SPECT) imaging for coronary artery disease, dipyridamole-thallium-201 SPECT imaging was performed in eight men with documented coronary artery disease before initiation of theophylline treatment and repeated while these patients were receiving therapeutic doses of oral theophylline. Before theophylline treatment, intravenous dipyridamole caused a significant increase in heart rate, decrease in blood pressure, angina in seven of eight patients, and ST segment depression in four of eight patients. While they were being treated with theophylline, none of the patients had angina or ST segment depression, and there were no hemodynamic changes with intravenous dipyridamole. Before theophylline treatment, dipyridamole-thallium-201 SPECT imaging showed reversible perfusion defects in myocardial segments supplied by stenotic coronary arteries. With theophylline treatment, dipyridamole-thallium-201 SPECT showed total absence of reversible perfusion defects. Treatment with theophylline markedly reduced the diagnostic accuracy of dipyridamole-thallium-201 imaging for coronary artery disease

  14. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  15. Dipyridamole thallium imaging for detecting cardiac involvement in patients with systemic sclerosis (scleroderma)

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Matsubara, Noboru; Tani, Akihiro; Morozumi, Takakazu; Hori, Masatsugu; Kitabatake, Akira; Kamada, Takenobu; Kimura, Kazufumi; Kozuka, Takahiro (Osaka Univ. (Japan). Faculty of Medicine)

    1990-02-01

    Dipyridamole thallium-201 imaging was carried out in 21 patients with progressive systemic sclerosis (PSS) to assess its value in detecting impaired myocardium and coronary microcirculation associated with PSS. Depending upon the degree of cardiac function, the patients were classified as having either ejection fraction of 50% or more (Group I, n=17) or less than 50% (Group II, n=4). In Group I, four patients had transient defect in which perfusion defects were seen on early images but not seen on delayed images; three had reverse redistribution in which defects were not seen on early images but seen on delayed images; and three had persistent defects which were seen on both early and delayed images. A decreased washout of thallium-201 was seen in 9 patients. In an analysis of both perfusion defects and washout rate, 13 patients (76%) in Group I were found to have abnormal findings. This suggests that disturbed coronary microcirculation or impaired myocardium may frequently develop even when EF is normal. All of the patients categorized as having a decreased cardiac function (Group II) had perfusion defect, suggesting the presence of myocardial fibrosis. In PSS, deterioration of cardiac function seemed to be associated with progression of myocardial fibrosis. Dipyridamole thallium imaging may be a sensitive method for detecting cardiac lesions in PSS. It also has the potential for detecting decreased coronary flow reserve or slightly impaired myocardium even without decreased EF. (N.K.).

  16. Clinical application of cerebral dynamic perfusion studies

    International Nuclear Information System (INIS)

    DeLand, F.H.

    1975-01-01

    Radionuclide cerebral perfusion studies are assuming a far greater importance in the detection and differential diagnosis of cerebral lesions. Perfusion studies not only contribute to the differential diagnosis of lesions but in certain cases are the preferred methods by which more accurate clinical interpretations can be made. The characteristic blood flow of arterio-venous malformations readily differentiates this lesion from neoplasms. The decreased perfusion or absent perfusion observed in cerebral infarctions is diagnostic without concurrent evidence from static images. Changes in rates and direction of blood flow contribute fundamental information to the status of stenosis and vascular occlusion and, in addition, offer valuable information on the competency and routes of collateral circulation. The degree of cerebral perfusion after cerebral vascular accidents appears to be directly related to patient recovery, particularly muscular function. Cerebral perfusion adds a new parameter in the diagnosis of subdural haematomas and concussion and in the differentiation of obscuring radioactivity from superficial trauma. Although pictorial displays of perfusion blood flow will offer information in most cerebral vascular problems, the addition of computer analysis better defines temporal relationships of regional blood flow, quantitative changes in flow and the detection of the more subtle increases or decreases in cerebral blood flow. The status of radionuclide cerebral perfusion studies has taken on an importance making it the primary modality for the diagnosis of cerebral lesions. (author)

  17. Ventricular premature contraction in hypertrophic cardiomyopathy and essential hypertension with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Kobiki, Naoki

    1989-01-01

    In order to investigate the relationship of different morbid states of the hypertrophied myocardium to the appearance of ventricular premature contraction (VPC), we compared the VPC findings from Holter ECG with those of UCG and stress thallium-201 myocardial SPECT scintigraphy (stress scinti) in 31 patients with hypertrophic cardiomyopathy (HCM) and 20 with essential hypertension (HT). The HCM patients consisted of 21 with asymmetric hypertrophy (ASH), 3 with symmetric hypertrophy (SH), and 7 with apical hypertrophy (APH). We recognized positive findings on the stress scinti such as fixed perfusion defect (FD) or reversible perfusion defect (RD) in 11 patients (ASH 10, APH 1) out of 31 patients with HCM (35%). Positive findings were observed in only one patient out of 20 with HT (5%). We recognized a high grade VPC (grade 4a and 4b of Lown's criteria) in 8 of 11 scinti positive patients with HCM (ASH 7, APH 1)(73%), while high grade VPC appeared in 5 (all of them are ASH) out of 20 scinti negative patients with HCM (25%). Therefore, these findings suggest that high grade VPCs in HCM occur in relation to a myocardial perfusion defect. (author)

  18. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy. With special reference to the 'mismatch' patterns and their significance

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Keiichiro; Miyamae, Tatsuya [Saitama Medical School (Japan)

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful.

  19. Post-operative monitoring of tissue transfers: advantages using contrast enhanced ultrasound (CEUS) and contrast enhanced MRI (ceMRI) with dynamic perfusion analysis?

    Science.gov (United States)

    Lamby, P; Prantl, L; Fellner, C; Geis, S; Jung, E M

    2011-01-01

    The immediate evaluation of microvascular tissue flaps with respect to microcirculation after transplantation is crucial for optimal monitoring and outcome. The purpose of our investigation was to evaluate the clinical value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced MRI (ceMRI) for monitoring the integrity of tissue flaps in plastic surgery. To this end, we investigated 10 patients (47 ± 16 a) between postoperative day 7 and 14 who underwent flap surgery in order to cover tissue defects in various body regions. For CEUS we utilized the GE LOGIQ E9 equipped with a linear transducer (6-9 MHz). After application of 2.4 ml SonoVue, the tissue perfusion was detected in Low MI-Technique (MI present, both technologies provide an optimal assessment of perfusion in cutaneous, subcutaneous and muscle tissue layers, whereby the detection of fatty tissue perfusion is currently more easily detected using CEUS compared to ceMRI.

  20. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy; Valutazione del significato emodinamico di fistole coronariche artero-venose. Integrazione diagnostica tra angiografia coronarica e scintigrafia miocardica a riposo e sotto sforzo

    Energy Technology Data Exchange (ETDEWEB)

    Rubini, G.; Sebastiani, M. [Bari Univ., Bari (Italy). Cattedra di Medicina Nucleare; Ettorre, G. C. [Foggia Univ., Foggia (Italy). Cattedra di Radiologia; Bovenzi, F. [Ospedale Policlinico, Unita' Operativa di Cardiologia, Bari (Italy)

    2000-12-01

    It is here reported on the importance of the integration of data obtained from digital coronary angiography and stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography in evaluationing the hemodynamic significance of coronary arteriovenous fistulae. Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, trans thoracic echocardiography, stress electrocardiogram and stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography. Stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a suocclusive stenosis of the right coronary artery and anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic

  1. Scintigraphy with Tc99m-MIBI to annual prediction the evolution of women referred for evaluation of precordial pain

    International Nuclear Information System (INIS)

    Peix, Amalia; Chacon, Deylis; Ponce, Felizardo; Lopez, Adlin; Cabrera, Omar; Maltas, Ana Ma.; Carrillo, Regla

    2002-01-01

    In order to evaluate the capacity of myocardial perfusion scintigraphy with Tc99m-MIBI to predict the evolution of women referred for evaluation of precordial pain, the rates of cardiovascular events at one year were studied in a group of patients with normal scintigraphy (group 1: 17 patients) and in another with reversible perfusion defects (group 2: 17 patients). The one-day protocol was applied for scintigraphy with Tc99m-MIBI (rest/stress) with combined stress (ergometrin bicycle plus 0.28 mg/Ig of dipyridamole) in those cases where it was necessary. A quantitative and qualitative analysis of the regional uptake was made. Patients from group 1 were younger than those from group 2 (average age: 49 vs 55, respectively, p = 0.04) and they had less hypercholesterolemia (112 % vs 59 %, respectively, p = 0.01). The rates of appearance of cardiovascular events at one year were calculated for patients from group 2 by using the Kaplan-Meier's method. The rates of appearance of clinical events (myocardial infarction and unstable angina) and of revascularization procedures (percutaneous transluminal coronary angioplasty and aortocoronary bypass surgery) were 0.24 in both cases. Only a patient from group 1 presented varying angina at 5 months. No deaths were reported in any of the groups. 94 % of the patients with normal perfusion scintigraphy were free of events after a one-year follow-up, whereas only 53 % of those with reversible perfusion defects showed a similar behavior. It was concluded that myocardial perfusion scintigraphy with Tc99m-MIBI is a useful tool to predict the evolution of women referred for evaluation of precordial pain at one year

  2. Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaemena, Andreas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)], E-mail: andreas.kaemena@charite.de; Streitparth, Florian; Grieser, Christian; Lehmkuhl, Lukas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany); Jamil, Basil [Department of Radiotherapy, Charite-Medical University Berlin, Schumannstr. 20/21, D-10117 Berlin (Germany); Wojtal, Katarzyna; Ricke, Jens; Pech, Maciej [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)

    2007-10-15

    Purpose: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. Material and methods: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7 s, two adjacent 10 mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4 s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. Results: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1 s. Conclusion: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.

  3. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  4. Correlation between melphalan pharmacokinetics and hepatic toxicity following hyperthermic isolated liver perfusion for unresectable metastatic disease.

    Science.gov (United States)

    Mocellin, Simone; Pilati, Pierluigi; Da Pian, Pierpaolo; Forlin, Marco; Corazzina, Susanna; Rossi, Carlo Riccardo; Innocente, Federico; Ori, Carlo; Casara, Dario; Ujka, Francesca; Nitti, Donato; Lise, Mario

    2007-02-01

    In the present work, we report on the results of our pilot study of hyperthermic isolated hepatic perfusion (IHP) with melphalan alone for patients with unresectable metastatic liver tumors refractory to conventional treatments, with particular regard to the correlation between pharmacokinetic findings and hepatic toxicity. Inclusion criteria were unresectable liver metastases, hepatic parenchyma replacement perfusion circuit were assessed by a radiolabeled albumin-based method. Drug concentrations in perfusate and plasma were measured by means of high-performance liquid chromatography (HPLC). Twenty patients with unresectable liver metastases underwent IHP. No intraoperative mortality occurred. Treatment-related systemic toxicity was minimal and reversible. Three patients (15%) experienced grade 4 hepatic toxicity and died due to liver failure and subsequent multiorgan failure. Other six patients had significant (grade 3-4) but transitory hepatic toxicity. Complete and partial responses were observed in three and nine out of 17 evaluable patients, respectively (overall response rate = 70%). The pharmacokinetics study showed a 3% mean perfusate-to-plasma drug leakage (range 1-6%). Logistic regression analysis showed that drug concentration in the perfusate circuit, but not preoperative tests, significantly and independently correlated with hepatic toxicity (P = 0.028). Following melphalan-based IHP, objective tumor regression could be observed in a remarkable percentage of patients refractory to standard treatments. However, hepatic toxicity and related mortality were significant. Our findings suggest that drug dosage personalization based on the measurement of drug distribution volumes might minimize

  5. Characteristics of Brain Perfusion in Patients of Parkinson's Disease

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Park, Min Jung; Kim, Jae Woo; Kang, Young Kang

    2008-01-01

    It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Two hundred nineteen patients (M: 70, F: 149, mean age: 62.9±6.9 y/o) who were diagnosed as PD without dementia clinically and 55 patients (M: 15, F: 40, mean age: 61.4±9.2 y/o) as normal controls who had no past illness history were performed 99m Tc-HMPAO brain perfusion SPECT and neuropsychological test. At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal cerebral blood

  6. Hybrid Algorithms for Fuzzy Reverse Supply Chain Network Design

    Science.gov (United States)

    Che, Z. H.; Chiang, Tzu-An; Kuo, Y. C.

    2014-01-01

    In consideration of capacity constraints, fuzzy defect ratio, and fuzzy transport loss ratio, this paper attempted to establish an optimized decision model for production planning and distribution of a multiphase, multiproduct reverse supply chain, which addresses defects returned to original manufacturers, and in addition, develops hybrid algorithms such as Particle Swarm Optimization-Genetic Algorithm (PSO-GA), Genetic Algorithm-Simulated Annealing (GA-SA), and Particle Swarm Optimization-Simulated Annealing (PSO-SA) for solving the optimized model. During a case study of a multi-phase, multi-product reverse supply chain network, this paper explained the suitability of the optimized decision model and the applicability of the algorithms. Finally, the hybrid algorithms showed excellent solving capability when compared with original GA and PSO methods. PMID:24892057

  7. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Nylander Eva

    2008-03-01

    Full Text Available Abstract Background Myocardial perfusion imaging (MPI, using single photon emission computed tomography (SPECT is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82, with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.

  8. Alternating Wolff-Parkinson-White syndrome associated with attack of angina

    International Nuclear Information System (INIS)

    Mangiafico, R.A.; Petralito, A.; Grimaldi, D.R.

    1990-01-01

    In a patient with Wolff-Parkinson-White syndrome and an inferior-posterior bypass tract, transient restoration of normal conduction occurred during an attack of angina. The ECG pattern of inferior posterior ischemia was present when the conduction was normal. Thallium scintigraphy showed a reversible posterolateral perfusion defect. The possible mechanisms for production of intermittent preexcitation are discussed

  9. Alternating Wolff-Parkinson-White syndrome associated with attack of angina

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, R.A.; Petralito, A.; Grimaldi, D.R. (Univ. of Catania (Italy))

    1990-07-01

    In a patient with Wolff-Parkinson-White syndrome and an inferior-posterior bypass tract, transient restoration of normal conduction occurred during an attack of angina. The ECG pattern of inferior posterior ischemia was present when the conduction was normal. Thallium scintigraphy showed a reversible posterolateral perfusion defect. The possible mechanisms for production of intermittent preexcitation are discussed.

  10. Noninvasive evaluation of regional myocardial perfusion in 112 patients using a mobile scintillation camera and intravenous nitrogen-13 labeled ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, W.F.; Harper, P.V.; Resnekov, L.; Fill, H.

    1976-08-01

    The short half-life positron emitter /sup 13/N, as labeled ammonia (/sup 13/NH/sub 4//sup +/), was evaluated as a myocardial imaging agent. Regional myocardial uptake of /sup 13/NH/sub 4/ correlated with the distribution of labeled microspheres in experimental myocardial infarction. Using intravenous /sup 13/NH/sub 4//sup +/, myocardial scintigraphy was performed in 85 cardiac patients and 27 normal subjects. Ninety-five scintigrams were suitable for analysis. Eighteen of 24 normal subjects had homogeneous myocardial images; six had inhomogeneous images attributable to early technical problems. Perfusion defects were observed in the scintigrams of 82% (57/65) of patients with coronary artery disease, being most common in patients with myocardial infarction (27/28). Six sequential studies showed changes in perfusion consistent with the clinical course of each patient. Scintigraphic abnormalities were also observed in 4/6 patients with valvular heart disease. /sup 13/NH/sub 4//sup +/ myocardial scintigraphy is a valid and sensitive method of assessing regional myocardial perfusion and is especially useful for sequential imaging at short intervals.

  11. Regional Cerebral Perfusion in Progressive Supranuclear Palsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Yong; Lee, Ki Hyeong; Yoon, Byung Woo; Lee, Sang Bok; Jeon, Beom S. [Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Han; Lee, Myung Chul [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1996-03-15

    Progressive supranuclear palsy (PSP) is a Parkinson-plus syndrome characterized clinically by supranuclear ophthalmoplegia, pseudobulbar palsy, axial rigidity, bradykinesia, postural instability and dementia. Presence of dementia and lack of cortical histopathology suggest the derangement of cortical function by pathological changes in subcortical structures in PSP, which is supported by the pattern of behavioral changes and measurement of brain metabolism using positron emission tomography. This study was done to examine whether there are specific changes of regional cerebral perfusion in PSP and whether there is a correlation between severity of motor abnormaility and degree of changes in cerebral perfusion. We measured regional cerebral perfusion indices in 5 cortical and 2 subcortical areas in 6 patients with a clinical diagnosis of PSP and 6 healthy age and sex matched controls using Tc-99m-HMPAO SPECT. Compared with age and sex matched controls, only superior frontal regional perfusion index was significantly decreased in PSP (p<0.05). There was no correlation between the severity of the motor abnormality and any of the regional cerebral perfusion indices (p>0.05). We affirm the previous reports that perfusion in superior frontal cortex is decreased in PSP. Based on our results that there was no correlation between severity of motor abnormality and cerebral perfusion in the superior frontal cortex, nonmotoric symptoms including dementia needs to be looked at whether there is a correlation with the perfusion abnormality in superior frontal cortex

  12. Placental perfusion in 3rd trimester pregnancy

    Science.gov (United States)

    Sitepu, M.; Syahriza, A.; Sibuea, D.; Hanafiah, T. M.

    2018-03-01

    The placenta is an organ for transmitting nutrition and oxygen to thefetus; it means if there is a defect in the placenta could make growth restriction to the fetus, even death. Uterine artery flow escalated since the halfway point of the pregnancy or the complete trophoblast invasion of spiralis artery, and keep going in every week. 3D power Doppler examination on placenta could show the uterineplacenta circulation and fetoplacental at once so could give themore accurate result. A cross-sectional study in RSUP HAM and theprivate specialist clinic was conducted in 100 pregnant samples with 28-40 week gestational age, exact last menstrual period date, and no underlying disease to examine the alteration of placental perfusion by gestationalage and placental location. There was a correlation between VI and VFI in placenta toward umbilical artery flow, but no correlation in FI. The placental location also plays a role in interval blood flow, especially FI and VFI, it means the VFI hold the strongest correlation in both ways.

  13. Regional Cerebral Perfusion in Progressive Supranuclear Palsy

    International Nuclear Information System (INIS)

    Lee, Won Yong; Lee, Ki Hyeong; Yoon, Byung Woo; Lee, Sang Bok; Jeon, Beom S.; Lee, Kyung Han; Lee, Myung Chul

    1996-01-01

    Progressive supranuclear palsy (PSP) is a Parkinson-plus syndrome characterized clinically by supranuclear ophthalmoplegia, pseudobulbar palsy, axial rigidity, bradykinesia, postural instability and dementia. Presence of dementia and lack of cortical histopathology suggest the derangement of cortical function by pathological changes in subcortical structures in PSP, which is supported by the pattern of behavioral changes and measurement of brain metabolism using positron emission tomography. This study was done to examine whether there are specific changes of regional cerebral perfusion in PSP and whether there is a correlation between severity of motor abnormaility and degree of changes in cerebral perfusion. We measured regional cerebral perfusion indices in 5 cortical and 2 subcortical areas in 6 patients with a clinical diagnosis of PSP and 6 healthy age and sex matched controls using Tc-99m-HMPAO SPECT. Compared with age and sex matched controls, only superior frontal regional perfusion index was significantly decreased in PSP (p 0.05). We affirm the previous reports that perfusion in superior frontal cortex is decreased in PSP. Based on our results that there was no correlation between severity of motor abnormality and cerebral perfusion in the superior frontal cortex, nonmotoric symptoms including dementia needs to be looked at whether there is a correlation with the perfusion abnormality in superior frontal cortex

  14. Computerized analysis of brain perfusion parameter images

    International Nuclear Information System (INIS)

    Turowski, B.; Haenggi, D.; Wittsack, H.J.; Beck, A.; Aurich, V.

    2007-01-01

    Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i. e., repetitions result in exactly the same output. (orig.)

  15. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Biological characterization of F-18-labeled rhodamine B, a potential positron emission tomography perfusion tracer.

    Science.gov (United States)

    Bartholomä, Mark D; He, Huamei; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; McGowan, Francis X; Cowan, Douglas B; Treves, S Ted; Packard, Alan B

    2013-11-01

    Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an (18)F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on (18)F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of (18)F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake (18)F-labeled rhodamine B by cardiomyocytes. A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100-150 μCi of (18)F-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [(18)F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Small-animal PET showed intense and uniform uptake of [(18)F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [(18)F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [(18)F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Fluorine-18

  17. Biological characterization of F-18-labeled rhodamine B, a potential positron emission tomography perfusion tracer

    International Nuclear Information System (INIS)

    Bartholomä, Mark D.; He, Huamei; Pacak, Christina A.; Dunning, Patricia; Fahey, Frederic H.; McGowan, Francis X.; Cowan, Douglas B.; Treves, S. Ted; Packard, Alan B.

    2013-01-01

    Introduction: Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an 18 F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on 18 F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of 18 F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake 18 F-labeled rhodamine B by cardiomyocytes. Methods: A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100–150 μCi of 18 F-labeled rhodamine B diethylene glycol ester ([ 18 F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1 mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [ 18 F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Results: Small-animal PET showed intense and uniform uptake of [ 18 F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [ 18 F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ∼ 40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [ 18 F]RhoBDEGF in the mitochondria

  18. Relationship between plasma BNP level and perfusion and function of the left ventricle in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Celinski, R.; Cholewinski, W.; Stefaniak, B.; Tarkowska, A.; Grzywa-Celinska, A.

    2004-01-01

    Elevation of the plasma BNP is known to occur in heart failure. However, some observations suggest that in patients with CAD an increase in BNP level may be caused also by the myocardial ischaemia. The study population comprised 79 patients with CAD, aged on average 59.6, and 18 healthy volunteers (CG). In patients with CAD g SPECT was performed using 99mT c tetrofosmin and myocardial perfusion and function were assessed quantitatively. Plasma BNP was measured using immunoradiometric method and was analyzed according to LVEF, EDV, ESV and two perfusion parameters: SCD and TPD. In all patients with CAD perfusion defects were found at rest. BNP concentration was significantly higher in CAD than in CG. In the group with dLVEF plasma BNP was distinctly higher than in that with nVEF but that difference was not significant. In pts with dLVEF significant correlation was found between BNP concentration on one hand and LVEF, EDV and ESV on the other. No significant relationships were observed between plasma BNP and both perfusion parameters. In patients with CAD the increase in plasma BNP level is related to the disorders of the left ventricular contractility, to the systolic function impairment first of all. Myocardial ischaemia without concomitant contractility disorders does not lead to elevation of BNP level. (author)

  19. Clinical evaluation of brain perfusion scintigraphy using N-isopropyl-p-( sup 123 I)-iodoamphetamine

    Energy Technology Data Exchange (ETDEWEB)

    Shimbo, Shin-ichiro; Yamamoto, Itsuo; Yagi, Kenji; Misaki, Takashi; Dokoh, Shigeharu (Kyoto City Hospital (Japan))

    1989-10-01

    The present study includes 16 patients with symptoms related to cerebrovascular insufficiency, who were randomly selected from out outpatient clinic of internal medicine. Single photon emission computed tomography (SPECT) with 111{approx}185 MBq (3{approx}5 mCi) of N-isopropyl-p-({sup 123}I)-iodoamphetamine (IMP) was performed 20 min and 3 hr after intravenous administration of the tracer, and compared to the image of conventional X-ray computed tomography (X-CT). Out of twelve cases with significant findings in X-CT, 9 showed corresponding changes in perfusion in SPECT with IMP, and the remaining 3 did not. In a patient with cerebral infarction, SPECT revealed a perfusion defect whereas her X-CT was negative, thereby proved to be useful in determining the focus of clinically suspected stroke. There were some other cases in which findings in SPECT and X-CT were discordant. From our series of scans, SPECT seemed useful in detecting responsible sites of neurological deficits in early and, occasionally, remote phases of cerebrovascular accidents, while X-CT appeared superior in finding smaller lesions. (author).

  20. Quantitative gated SPECT- a comparative study of two algorithms for parameters of perfusion and LV function

    International Nuclear Information System (INIS)

    Ali, A.Z.

    2007-01-01

    Full text: Aim: To compare the perfusion and LV function parameters as quantified by 4D-MSPECT and ECT in the same patient group and a qualitative comparison of the reconstructed slices by two different experts. Materials and methods: Thirty-one consecutive patients underwent gated myocardial perfusion SPECT using a two-day protocol. The gated and ungated data were reconstructed by back projection method. Quantitative analysis was performed on the same set of reconstructed slices by 4D-MSPECT and Emory Cardiac Tool Box. The reconstructed slices were read qualitatively by two different experts on their respective systems. Polar map and functional analysis was performed in both softwares and the results were compared. Results: The concordance between the two experts qualitatively was seen in 78/93(84%) coronary territories. The polar map defects were comparable in LAD (r-value of 0.87) and LCX (r-value of 0.76) territories whereas RCA defects (r-value of 0.04) were not at all correlating. The defect severity showed concordance in 68/93 (73%) coronary territories. There was concordance between 4DMSPECT and the qualitative interpretation in 84/93 (90%) coronary territories whereas ECT showed concordance in only 70/93(75%) coronary territories. The overall sensitivity is marginally higher for ECT (100% vs. 96%) but the overall specificity is much higher with 4 DMSPECT (88% vs. 65%). ESV showed good correlation(r=0.94) of the two softwares with no significant difference in means. EDV and LVEF although had good correlation(r = 0.96 and 0.89) showed high difference in means (p<0.01). Conclusion: Between 4D-MSPECT and ECT, 4D-MSPECT is marginally superior to ECT with reference to qualitative interpretation in view of better specificity. The LVEF values between the two softwares should also not be used interchangeably. (author)

  1. Effects of isosorbide dinitrate on exertion-induced anomalous myocardial perfusion in coronary diseases studied with the aid of 201Th scintiscanning

    International Nuclear Information System (INIS)

    Wolf, R.; Pretschner, P.; Engel, H.J.; Hundeshagen, H.; Lichtlen, P.R.; Medizinische Hochschule Hannover

    1979-01-01

    The effect of isosorbide dinitrate (ISDN) (10 mg sublingually) on myocardial perfusion under ischemic conditions was analyzed in 14 patients with angiographically severe coronary artery disease and typical angina pectoris, using 201-thallium-myocardial scintiscanning. All patients underwent two identical scintiscans with the same work load during bicycle ergometry; a control scintiscan leading to angina and ST-depressions of > 0.1 mV was followed 4-6 weeks later by a scintiscan after ISDN; all drugs - except sublingual nitroglycerin - were withheld for an entire week. - Results: 25 of 39 new or enlarged, exercise-induced defects (64%) were normalized after ISDN; 14 new or enlarged defects remained unchanged (p [de

  2. Myocardial perfusion assessed by contrast echocardiography and single photon emission computed tomography in the evaluation of patients with acute chest pain and normal electrocardiogram

    International Nuclear Information System (INIS)

    Soares, J. Jr.; Ferreira, S.M.A.; Matias, W. Jr.; Giorgi, M.C.P.; Izaki, M.; Luz, P.L.; Ramires, J.A.F.; Meneghetti, J.C.

    2002-01-01

    Aim : Evaluation of diagnostic accuracy of myocardial contrast echocardiography (MCE) in comparison with single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia in patients with acute chest pain. Material and Methods : Eighteen patients (pts) with chest pain lasting ≥30 minutes, occurring within 6 hours of emergency room presentation and a normal or no diagnostic electrocardiogram were studied. Pts underwent rest MCE and SPECT. For both exams myocardial perfusion was assessed in the same 7 segments (apical, anterior, inferior, anteroseptal, inferoseptal, lateral and posterior) of left ventricle. A total of 126 segments were analyzed. Images were classified as positive for ischemia if they had a perfusion defect. Coronary angiography was performed if MCE or SPECT images were classified as positive for ischemia or by clinical indication. Otherwise the patients underwent stress SPECT. Significant coronary artery disease (CAD) was defined as ≥70% stenosis in a major coronary artery or its branches. Final diagnosis of an acute coronary event (ACE) was established in the presence of positive findings in MCE or SPECT in addition to significant CAD in the corresponding territory. Kappa statistics were calculated to evaluate the concordance between MCE and SPECT. κ values of ≤0.4, >0.4 and >0.7 indicate fair, good and excellent agreement, respectively. Results: Thirteen out of 18 pts underwent coronary angiography (seven pts had positive findings on SPECT, 2 on MCE, 2 on both exams and 1 had clinical indication). Significant CAD was detected on six. Five pts underwent stress SPECT and no perfusion defect was detected. Therefore, six pts (33.3%) had an ACE and 12 (66.6%) had not. There were no statistical differences between groups according to age, gender, duration of pain, free pain interval, presence of risk factors and antecedents. Concordance between MCE and SPECT for evaluation of perfusion defects showed a ? coefficient of 0

  3. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  4. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Moustafa, H; Elhaddad, SH; Wageeh, SH; Samy, A; Abdo, S [Nuclear medicine and radiology department, faculty of medicine and Cairo university, Cairo, (Egypt)

    1995-10-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs.

  5. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Moustafa, H.; Elhaddad, SH.; Wageeh, SH.; Samy, A.; Abdo, S.

    1995-01-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs

  6. Reverse redistribution of thallium-201: a sign of nontransmural myocardial infarction with patency of the infarct-related coronary artery

    International Nuclear Information System (INIS)

    Weiss, A.T.; Maddahi, J.; Lew, A.S.; Shah, P.K.; Ganz, W.; Swan, H.J.; Berman, D.S.

    1986-01-01

    The pattern of reverse redistribution on the day 10 poststreptokinase resting thallium-201 myocardial scintigrams is a common finding in patients who have undergone streptokinase therapy in evolving myocardial infarction. To investigate this phenomenon, 67 patients who underwent streptokinase therapy were studied pre- and 10 days poststreptokinase therapy resting thallium-201 studies, poststreptokinase therapy resting radionuclide ventriculography and coronary arteriography (60 of the 67 patients). Of the 67 patients, 50 (75%) showed the reverse redistribution pattern on the day 10 thallium-201 study (Group I), 9 (13%) had a nonreversible defect (Group II) and the remaining 8 (12%) had a normal study or showed a reversible defect (Group III). The reverse redistribution pattern was associated with patency of the infarct-related artery (100%), quantitative improvement in resting thallium-201 defect size from day 1 to day 10 study (94%) and normal or near normal wall motion on day 10 radionuclide ventriculography (80% of segments with marked and 54% of those with mild reverse redistribution). In contrast, nonreversible defects were associated with significantly less frequent patency of the infarct-related artery (67%, p = 0.01), improvement in defect size (11%, p less than 0.001) and normal or near normal wall motion (21%, p less than 0.05). Group III patients were similar to Group I with respect to these variables. The quantitated thallium-201 percent washout was higher in the regions with the reverse redistribution pattern (49 +/- 15%) compared with the contralateral normal zone (24 +/- 15%, p less than 0.001)

  7. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    Science.gov (United States)

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  8. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  9. Auxílio à detecção de anormalidade perfusional miocárdica utilizando atlas de SPECT e registro de imagens: resultados preliminares Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Directory of Open Access Journals (Sweden)

    Rodrigo Donizete Santana de Pádua

    2008-12-01

    Full Text Available OBJETIVO: Criar um atlas de cintilografia de perfusão miocárdica e verificar sua aplicabilidade no auxílio computadorizado à detecção de defeitos perfusionais miocárdicos em pacientes portadores de cardiopatia isquêmica. MATERIAIS E MÉTODOS: O atlas foi criado com imagens de cintilografia de perfusão miocárdica, em condições de repouso e estresse, de 20 pacientes de ambos os gêneros com baixa probabilidade de doença arterial coronariana e julgadas normais por dois observadores experientes. Técnicas de registro de imagens e operações matemáticas sobre imagens foram utilizadas para obtenção de modelos de média e desvio-padrão da captação miocárdica percentual de cada gênero e condição fisiológica. RESULTADOS: Imagens de um paciente masculino e um feminino foram alinhadas com os atlas correspondentes, e os voxels apresentando valores de captação percentual dois desvios-padrão abaixo da média da respectiva região do atlas foram destacados nos cortes tomográficos e confirmados como defeitos de perfusão por dois observadores experientes. CONCLUSÃO: Demonstramos a criação de um atlas de cintilografia de perfusão miocárdica e obtivemos resultados promissores na sua utilização para auxílio à detecção de defeitos perfusionais. Entretanto, uma validação prospectiva com um número mais representativo de casos é necessária.OBJECTIVE: To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. MATERIALS AND METHODS: The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and

  10. Posterior Reversible Encephalopathy (PRES)

    International Nuclear Information System (INIS)

    Moron E, Fanny E; Diaz Marchan, Pedro

    2005-01-01

    The Posterior Reversible Encephalopathy Syndrome (PRES) is a clinical Syndrome composed of cephalea, alteration in vision and convulsions, usually observed in patients with sudden elevation of arterial pressure. The imagenologic evidence shows reversible vasogenic brain edema without stroke. Its location is predominantly posterior; it affects the cortex and the subcortical white matter of the occipital, parietal and temporal lobes. The treatment with antihypertensive drugs and the removing of immunosupressor medication are generally associated with complete neurological recovery; this is reflected also in the images which return to their basal condition. The untreated hypertension, on the other side, can result in a progressive defect of the autoregulation system of the central nervous system with cerebral hemorrhage, irreversible brain stroke, coma and death

  11. Cerebral perfusion disorders in patients after craniocerebral injury with clinical temporal conus syndrome

    International Nuclear Information System (INIS)

    Prasek, J.; Smrcka, M.; Maca, K.; Juran, V.; Vidlak, M.; Smrcka, V.

    2002-01-01

    Aim: to evaluate the changes of cerebral perfusion in patients after craniocerebral injury with clinical temporal conus syndrome. Material and methods: We present a group of 14 head injured patients admitted to neurosurgery with the syndrome of temporal herniation (Glasgow coma scale 3 - 5, homorateral dilated pupil and disturbed vital functions). There were 7 epidural, 6 subdural and one intracerebral hematomas. Mean age was 42, 7. All patients had urgent surgery and then continuous monitoring of vital functions. Results: Two postoperative CT and SPECT examinations were performed in each patient. Only 2 patients had visible ischemia on the first postoperative CT scan, both diet. 11 patients had ischemia in both the first post-operative and the follow up SPECT. 7 patients had improvement on the follow up SPECT compared to the first one, 6 of them were good results, one died. Conclusions: SPECT is very sensitive to impaired cerebral perfusion and may be helpful as a serial study. This is very mainly in the patients with reversible ischemia which may be influenced therapeutically with good results

  12. Ventilation and perfusion display in a single image

    International Nuclear Information System (INIS)

    Lima, J.J.P. de; Botelho, M.F.R.; Pereira, A.M.S.; Rafael, J.A.S.; Pinto, A.J.; Marques, M.A.T.; Pereira, M.C.; Baganha, M.F.; Godinho, F.

    1991-01-01

    A new method of ventilation and perfusion display onto a single image is presented. From the data on regions of interest of the lungs, three-dimensional histograms are created, containing as parameters X and Y for the position of the pixels, Z for the perfusion and colour for local ventilation. The perfusion value is supplied by sets of curves having Z proportional to the local perfusion count rate. Ventilation modulates colour. Four perspective views of the histogram are simultaneously displayed to allow visualization of the entire organ. Information about the normal ranges for both ventilation and perfusion is also provided in the histograms. (orig.)

  13. Effects of Steroid Hormones on Sex Differences in Cerebral Perfusion.

    Directory of Open Access Journals (Sweden)

    Carmen Ghisleni

    Full Text Available Sex differences in the brain appear to play an important role in the prevalence and progression of various neuropsychiatric disorders, but to date little is known about the cerebral mechanisms underlying these differences. One widely reported finding is that women demonstrate higher cerebral perfusion than men, but the underlying cause of this difference in perfusion is not known. This study investigated the putative role of steroid hormones such as oestradiol, testosterone, and dehydroepiandrosterone sulphate (DHEAS as underlying factors influencing cerebral perfusion. We acquired arterial spin labelling perfusion images of 36 healthy adult subjects (16 men, 20 women. Analyses on average whole brain perfusion levels included a multiple regression analysis to test for the relative impact of each hormone on the global perfusion. Additionally, voxel-based analyses were performed to investigate the sex difference in regional perfusion as well as the correlations between local perfusion and serum oestradiol, testosterone, and DHEAS concentrations. Our results replicated the known sex difference in perfusion, with women showing significantly higher global and regional perfusion. For the global perfusion, DHEAS was the only significant predictor amongst the steroid hormones, showing a strong negative correlation with cerebral perfusion. The voxel-based analyses revealed modest sex-dependent correlations between local perfusion and testosterone, in addition to a strong modulatory effect of DHEAS in cortical, subcortical, and cerebellar regions. We conclude that DHEAS in particular may play an important role as an underlying factor driving the difference in cerebral perfusion between men and women.

  14. Diagnostic value of exercise induced 18F-FDG myocardial metabolism scintigraphy in myocardial ischemia

    International Nuclear Information System (INIS)

    Shen Rui; He Zuoxiang; Shi Rongfang; Liu Xiujie; Tian Yueqin; Guo Feng; Wei Hongxing; Wu Yongjian; Qin Xuewen; Gao Runlin

    2006-01-01

    Objective: To evaluate the feasibility and diagnostic accuracy of exercise induced myocardial imaging with 18 F-fluorodeoxyglucose (FDG) in myocardial ischemia. Methods: Twenty-six patients with known or suspected coronary artery, disease (CAD) and with no prior myocardial infarction underwent simultaneous myocardial perfusion and metabolism imaging following intravenous injection of 99 Tc m -methoxy-isobutylisonitrile ( 99 Tc m -sestamibi) and 18 F-FDG at peak exercise. Subsequently rest perfusion imaging and coronary angiography (CAG) were performed in all patients. Exercise 18 F-FDG myocardial imaging was compared with 99 Tc m -sestamibi imaging and CAG. Results: In 22 patients with ≥50% narrowing over l coronary artery, 18 had perfusion abnormalities (sensitivity 82%), whereas 20 had abnormal myocardial 18 F-FDG uptake (sensitivity 91%, P>0.05). Patients with reversible (12 cases) or partial reversible (3 cases) perfusion abnormalities had increased myocardial 18 F-FDG uptake in abnormal perfusion segments. Compared with CAG, perfusion defect was seen in myocardial segments corresponding to 25 vascular territories of 51 vessels with ≥50% narrowing in 22 patients in 99 Tc m -sestamibi imaging (sensitivity 49%), whereas increased 18 F-FDG uptake was seen in 34 vascular territories (sensitivity 67%, P=0.008). Conclusions: Exercise induced myocardial ischemia can be imaged directly with 18 F-FDG. Combined exercise 18 F-FDG and 99 Tc m -sestamibi imaging provides a better assessment of exercise-induced myocardial ischemia as compared with exercise-rest perfusion imaging. (authors)

  15. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  16. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  17. Perfusion-weighted MR imaging of uterine leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Takase, Hiroyasu; Munechika, Hirotsugu [Showa Univ., Tokyo (Japan). School of Medicine

    2001-06-01

    Serial images of uterine leiomyoma in gradient-echo, echo-planar, magnetic resonance imaging were taken to draw a {delta}R2{sup *} curve after intravenous bolus injection of Gd-DTPA. The {delta}R2{sup *} integral was calculated from a {delta}R2{sup *} curve to have relative perfusion of uterine leiomyoma. We then, evaluated the amount of perfusion correlated with MR findings, size and number of leiomyoma or the clinical symptoms and established that perfusion was correlated positively with the findings of T2 weighted images and clinical symptoms but not with other MR findings or size and number of leiomyoma. In conclusion, we presumed that the clinical symptoms could be reduced by decreasing of an amount of perfusion of uterine leiomyoma in some means. However, it remained uncertain why severe clinical symptoms were associated with a high amount of perfusion in uterine leiomyomas. (author)

  18. Both semiquantitative degree of rest Tl-201 uptake and reversibility at 24 hour-delay were needed to predict wall motion improvement after bypass surgery

    International Nuclear Information System (INIS)

    Lee, D. S.; Yoon, S. N.; Kim, K. B.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Controversy still exists about how to use the uptake at rest and 24 hour delay in rest redistribution Tl-201 SPECT to predict improvement of wall motion abnormality after bypass surgery. To find the best way to combine diagnostic efficacy of Tl-201 SPECT to predict myocardial viability, we studied the predictive values (positive: PPV, negative: NPV) of rest and 24 hour-delay Tl-201 SPECT in 21 patients. Wall motion was assessed comparing preoperative post-stress gated Tc-99m-MIBI SPECT with that of 3 months after surgery. Four point scoring system was used for 17 myocardial segments to asses uptakes ( 0 to 3 for normal to defect) at rest and 24 hour-delay and wall motion ( 0 to 3 for normal to dyskinesia). Ejection fraction improved after surgery (5011% vs 4313%). Intra-observer and inter-observer reproducibility of EF was 7 and 9% respectively when we used 3D Perfusion-Motion Map. Sixty seven segments showed wall motion abnormality before surgery. Predictive values of rest Tl-201 uptake decrease were as follows: 0: 15/15(100%), 1: 30/34(88%), 2: 6/11 (55%), 3: 3/7(43%). So PPV of mild decrease was 88%, and NPV of severe decrease was 50%. Delayed reversibility was evaluated in 37 segments (15 patients). Twenty seven segment had persistence or aggravation, but the other 10 segments improved at 24 hour delay. PPV of reversible 10 segments was 80%, and NPV of reversibility was only 46%. PPV of combination of rest Tl-201 uptake of mild degree and 24 hour reversibility was 86% (38/44) and NPV of neither one was 88%. We concluded that both semi-quantitative degree of Tl-201 uptake at rest and reversibility at 24 hour delay was the best to warrant or abandon postoperative improvement of abnormal wall motion found at preoperative post-stress gated myocardial SPECT

  19. Hepatic sinusoid is not well-stirred: estimation of the degree of axial mixing by analysis of lobular concentration gradients formed during uptake of thyroxine by the perfused rat liver

    International Nuclear Information System (INIS)

    Weisiger, R.A.; Mendel, C.M.; Cavalieri, R.R.

    1986-01-01

    Two general models have been proposed for predicting the effects of metabolism, protein binding, and plasma flow on the removal of drugs by the liver. These models differ in the degree of plasma mixing assumed to exist within each hepatic sinusoid. The venous equilibrium model treats the sinusoid as a single well-stirred compartment, whereas the sinusoidal model effectively breaks up the sinusoid into a large number of sequentially perfused compartments which do not exchange their contents except through plasma flow. As a consequence, the sinusoidal model, but not the venous equilibrium model, predicts that the concentration of highly extracted drugs will decline as the plasma flows through the hepatic lobule. To determine which of these alternative models best describes the hepatic uptake process, we looked for evidence that concentration gradients are formed during the uptake of [ 125 I]thyroxine by the perfused rat liver. Autoradiography of tissue slices after perfusion of the portal vein at physiologic flow rates with protein-free buffer containing [ 125 I]thyroxine demonstrated a rapid exponential fall in grain density with distance from the portal venule, declining by half for each 8% of the mean length of the sinusoid. Reversing the direction of perfusate flow reversed the direction of the autoradiographic gradients, indicating that they primarily reflect differences in the concentration of thyroxine within the hepatic sinusoids rather than differences in the uptake capacity of portal and central hepatocytes. Analysis of the data using models in which each sinusoid was represented by different numbers of sequentially perfused compartments (1-20) indicated that at least eight compartments were necessary to account for the magnitude of the gradients seen

  20. Regional myocardial perfusion of cardioplegic solutions

    International Nuclear Information System (INIS)

    Eugene, J.; Lyons, K.P.; Ott, R.A.; Gelezunas, V.L.; Chang, C.W.; Kowall, M.G.; Haiduc, N.J.

    1987-01-01

    We compared the regional myocardial perfusion of blood cardioplegic solution (BCP) and crystalloid cardioplegic solution (CCP) in 14 mongrel dogs. Cardiopulmonary bypass was established at 28 degrees C, and a hydraulic occluder was placed around the proximal left anterior descending (LAD) coronary artery. In group 1 (N = 7) collateral coronary arteries were ligated; in group 2 (N = 7) collateral coronary arteries were left in situ. After the aorta was clamped, BCP and CCP were alternately perfused at 200 ml/min. The occluder was inflated to produce moderate, severe, and critical LAD stenosis, and regional perfusion was measured by xenon-133 washout with the Silicon Avalanche Radiation Detector. BCP infusion produced a consistently higher aortic pressure, but CCP flow was better than BCP flow under all conditions, particularly without coronary collaterals. Regional myocardial perfusion of CCP is superior to BCP

  1. Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lim, Il Han; Kim, Ki Bong; Lee, Dong Soo

    2008-01-01

    Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F=28:27) of low-likelihood for coronary artery disease were enrolled and 201 Tl rest / 99m Tc-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. 201 Tl rest / 99m Tc-MIBI stress / 201 Tl 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, Q delay (perfusion measurement), Δ delay (Q delay .m) and Z delay ((Q delay .m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was 51.8±6.5 and the highest segmental perfusion was 87.0±5.9, and they are 58.7±8.1 and 87.3±6.0, respectively in women. In the viability assessment, Q delay showed AUC of 0.633, while those for Δ delay and Z delay were 0.735 and 0.716, respectively. The AUCs of Δ delay and Z delay were significantly higher than that of Q delay (p=0.001 and 0.018, respectively). The diagnostic performance of Δ delay , which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. On automatic

  2. Increased sinusoidal volume and solute extraction during retrograde liver perfusion

    International Nuclear Information System (INIS)

    Bass, N.M.; Manning, J.A.; Weisiger, R.A.

    1989-01-01

    Retrograde isolated liver perfusion has been used to probe acinar functional heterogeneity, but the hemodynamic effects of backward flow have not been characterized. In this study, extraction of a long-chain fatty acid derivative, 12-N-methyl-7-nitrobenzo-2-oxa-1,3-diazol-amino stearate (12-NBDS), was greater during retrograde than during anterograde perfusion of isolated rat liver. To determine whether hemodynamic differences between anterograde and retrograde perfused livers could account for this finding, the hepatic extracellular space was measured for both directions of flow by means of [ 14 C]sucrose washout during perfusion as well as by direct measurement of [ 14 C]sucrose entrapped during perfusion. A three- to fourfold enlargement of the total hepatic extracellular space was found during retrograde perfusion by both approaches. Examination of perfusion-fixed livers by light microscopy and morphometry revealed that marked distension of the sinusoids occurred during retrograde perfusion and that this accounts for the observed increase in the [ 14 C]sucrose space. These findings support the hypothesis that maximum resistance to perfusate flow in the isolated perfused rat liver is located at the presinusoidal level. In addition, increased transit time of perfusate through the liver and greater sinusoidal surface area resulting from sinusoidal distension may account for the higher extraction of 12-NBDS and possibly other compounds by retrograde perfused liver

  3. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  4. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  5. Measurement of the efficacy of 2% lipid in reversing bupivacaine- induced asystole in isolated rat hearts

    Science.gov (United States)

    2014-01-01

    Background The reversal efficacy of 2% lipid emulsion in cardiac asystole induced by different concentrations of bupivacaine is poorly defined and needs to be determined. Methods Forty-two male Sprague–Dawley rats were randomly divided into seven groups: B40, B60, B80, B100, B120, B140 and B160, n = 6. The Langendorff isolated heart perfusion model was used, which consisted of a balanced perfusion with Krebs-Henseleit solution for 25 minutes and a continuous infusion of 100 μmol/L bupivacaine until asystole had been induced for 3 minutes. The hearts in the seven groups were perfused with Krebs-Henseleit solution containing a 2% lipid emulsion, and 40, 60, 80, 100, 120, 140 or 160 μmol/L bupivacaine, respectively. Cardiac recovery was defined as a spontaneous and regular rhythm with a rate-pressure product > 10% of the baseline value for more than 1 minute. Our primary outcome was the rate-pressure product 25 minutes after cardiac recovery. Other cardiac function parameters were also recorded. Results All groups demonstrated cardiac recovery. During the recovery phase, heart rate, rate-pressure product, the maximum left ventricular pressure rise and decline in heart rate in the B120-B160 groups was significantly lower than those in the B40-B80 groups (P bupivacaine and the reversal effects of a 2% lipid emulsion showed a typical transoid S-shaped curve, R2 = 0.9983, IC50 value was 102.5 μmol/L (95% CI: 92.44 - 113.6). Conclusions There is a concentration-response relationship between the concentrations of bupivacaine and the reversal effects of 2% lipid emulsion. PMID:25089118

  6. Selective cerebral perfusion prevents abnormalities in glutamate cycling and neuronal apoptosis in a model of infant deep hypothermic circulatory arrest and reperfusion.

    Science.gov (United States)

    Kajimoto, Masaki; Ledee, Dolena R; Olson, Aaron K; Isern, Nancy G; Robillard-Frayne, Isabelle; Des Rosiers, Christine; Portman, Michael A

    2016-11-01

    Deep hypothermic circulatory arrest is often required for the repair of complex congenital cardiac defects in infants. However, deep hypothermic circulatory arrest induces neuroapoptosis associated with later development of neurocognitive abnormalities. Selective cerebral perfusion theoretically provides superior neural protection possibly through modifications in cerebral substrate oxidation and closely integrated glutamate cycling. We tested the hypothesis that selective cerebral perfusion modulates glucose utilization, and ameliorates abnormalities in glutamate flux, which occur in association with neuroapoptosis during deep hypothermic circulatory arrest. Eighteen infant male Yorkshire piglets were assigned randomly to two groups of seven (deep hypothermic circulatory arrest or deep hypothermic circulatory arrest with selective cerebral perfusion for 60 minutes at 18℃) and four control pigs without cardiopulmonary bypass support. Carbon-13-labeled glucose as a metabolic tracer was infused, and gas chromatography-mass spectrometry and nuclear magnetic resonance were used for metabolic analysis in the frontal cortex. Following 2.5 h of cerebral reperfusion, we observed similar cerebral adenosine triphosphate levels, absolute levels of lactate and citric acid cycle intermediates, and carbon-13 enrichment among three groups. However, deep hypothermic circulatory arrest induced significant abnormalities in glutamate cycling resulting in reduced glutamate/glutamine and elevated γ-aminobutyric acid/glutamate along with neuroapoptosis, which were all prevented by selective cerebral perfusion. The data suggest that selective cerebral perfusion prevents these modifications in glutamate/glutamine/γ-aminobutyric acid cycling and protects the cerebral cortex from apoptosis. © The Author(s) 2016.

  7. [An automatic system controlled by microcontroller for carotid sinus perfusion].

    Science.gov (United States)

    Yi, X L; Wang, M Y; Fan, Z Z; He, R R

    2001-08-01

    To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.

  8. Analysis of glutathione in supernatants and lysates of a human proximal tubular cell line from perfusion culture upon intoxication with cadmium chloride by HPLC and LC-ESI-MS

    NARCIS (Netherlands)

    Hahn, Hans; Huck, Christian W; Rainer, Matthias; Najam-ul-Haq, Muhammad; Bakry, Rania; Abberger, Thomas; Jennings, Paul; Pfaller, Walter; Bonn, Günther K

    A simple and highly effective reversed-phase (RP) high-performance liquid chromatography (HPLC) method is described for analysing glutathione (GSH) and glutathione disulfide (GSSG) in out-flowing supernatants and lysates of perfusion cell cultures of human kidney cells (HK-2 cells) continuously

  9. Insulin degradation products from perfused rat kidney

    International Nuclear Information System (INIS)

    Duckworth, W.C.; Hamel, F.G.; Liepnieks, J.; Peavy, D.; Frank, B.; Rabkin, R.

    1989-01-01

    The kidney is a major site for insulin metabolism, but the enzymes involved and the products generated have not been established. To examine the products, we have perfused rat kidneys with insulin specifically iodinated on either the A14 or the B26 tyrosine. Labeled material from both the perfusate and kidney extract was examined by Sephadex G50 and high-performance liquid chromatography (HPLC). In perfusate from a filtering kidney, 22% of the insulin-sized material was not intact insulin on HPLC. With the nonfiltering kidney, 10.6% was not intact insulin. Labeled material from HPLC was sulfitolyzed and reinjected on HPLC. By use of 125 I-iodo(A14)-insulin, almost all the degradation products contained an intact A-chain. By use of 125 I-iodo(B26)-insulin, several different B-chain-cleaved products were obtained. The material extracted from the perfused kidney was different from perfusate products but similar to intracellular products from hepatocytes, suggesting that cellular metabolism by kidney and liver are similar. The major intracellular product had characteristics consistent with a cleavage between the B16 and B17 amino acids. This product and several of the perfusate products are also produced by insulin protease suggesting that this enzyme is involved in the degradation of insulin by kidney

  10. Pulmonary artery perfusion versus no perfusion during cardiopulmonary bypass for open heart surgery in adults

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Grønlykke, Lars; Risom, Emilie C

    2018-01-01

    BACKGROUND: Available evidence has been inconclusive on whether pulmonary artery perfusion during cardiopulmonary bypass (CPB) is associated with decreased or increased mortality, pulmonary events, and serious adverse events (SAEs) after open heart surgery. To our knowledge, no previous systematic...... handsearched retrieved study reports and scanned citations of included studies and relevant reviews to ensure that no relevant trials were missed. We searched for ongoing trials and unpublished trials in the World Health Organization International Clinical Trials Registry Platform (ICTRP) and at clinicaltrials......). We used GRADE principles to assess the quality of evidence. MAIN RESULTS: We included in this review four RCTs (210 participants) reporting relevant outcomes. Investigators randomly assigned participants to pulmonary artery perfusion with blood versus no perfusion during CPB. Only one trial included...

  11. Prognostic value of preoperative dynamic contrast-enhanced MRI perfusion parameters for high-grade glioma patients

    Energy Technology Data Exchange (ETDEWEB)

    Ulyte, Agne [Vilnius University, Faculty of Medicine, Vilnius (Lithuania); Katsaros, Vasileios K. [General Anticancer and Oncological Hospital ' ' St. Savvas' ' , Department of Advanced Imaging Modalities - CT and MRI, Athens (Greece); University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); Liouta, Evangelia; Stranjalis, Georgios [University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); Boskos, Christos [University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); General Anticancer and Oncological Hospital ' ' St. Savvas' ' , Department of Radiation Oncology, Athens (Greece); Papanikolaou, Nickolas [Champalimaud Foundation, Department of Radiology, Centre for the Unknown, Lisbon (Portugal); Usinskiene, Jurgita [National Cancer Institute, Vilnius (Lithuania); Affidea Lietuva, Vilnius (Lithuania); Bisdas, Sotirios [University College London Hospitals, Department of Neuroradiology, The National Hospital for Neurology and Neurosurgery, London (United Kingdom)

    2016-12-15

    The prognostic value of the dynamic contrast-enhanced (DCE) MRI perfusion and its histogram analysis-derived metrics is not well established for high-grade glioma (HGG) patients. The aim of this prospective study was to investigate DCE perfusion transfer coefficient (K{sup trans}), vascular plasma volume fraction (v{sub p}), extracellular volume fraction (v{sub e}), reverse transfer constant (k{sub ep}), and initial area under gadolinium concentration time curve (IAUGC) as predictors of progression-free (PFS) and overall survival (OS) in HGG patients. Sixty-nine patients with suspected anaplastic astrocytoma or glioblastoma underwent preoperative DCE-MRI scans. DCE perfusion whole tumor region histogram parameters, clinical details, and PFS and OS data were obtained. Univariate, multivariate, and Kaplan-Meier survival analyses were conducted. Receiver operating characteristic (ROC) curve analysis was employed to identify perfusion parameters with the best differentiation performance. On univariate analysis, v{sub e} and skewness of v{sub p} had significant negative impacts, while k{sub ep} had significant positive impact on OS (P < 0.05). v{sub e} was also a negative predictor of PFS (P < 0.05). Patients with lower v{sub e} and IAUGC had longer median PFS and OS on Kaplan-Meier analysis (P < 0.05). K{sup trans} and v{sub e} could also differentiate grade III from IV gliomas (area under the curve 0.819 and 0.791, respectively). High v{sub e} is a consistent predictor of worse PFS and OS in HGG glioma patients. v{sub p} skewness and k{sub ep} are also predictive for OS. K{sup trans} and v{sub e} demonstrated the best diagnostic performance for differentiating grade III from IV gliomas. (orig.)

  12. Myocardial ischemia detection by artificial intelligence interpretation of Tl-201 tomograms

    International Nuclear Information System (INIS)

    Herbst, M.D.; Garcia, E.V.; Cooke, C.D.; Folks, R.D.; Ezquerra, N.F.

    1989-01-01

    This paper reports on an expert system environment which automatically assigned certainty factors to abnormal regions in stress and delayed myocardial thallium-201 polar bulls-eye plots. MYCIN-type algorithms propagated certainty factors for the presence, location, and character of each coronary lesion. Ninety-four previously validated rules that considered only stress perfusion defects spawned 91 new rules considering tracer redistribution. Fifteen new rules assessed vascular territories for the presence and location of fixed or reversible defects. This artificial intelligence tool can provide novice readers of cardiac T1-201 studies automatic, consistent, objective, and justified interpretations that consider artifacts, coronary territory overlap, and multiple defects

  13. Myocardial perfusion scintigraphy - possibilities of diagnosing CAD

    International Nuclear Information System (INIS)

    Tsonevska, A.

    1998-01-01

    A reviewing the diagnostic methods used in the intricate process of evaluating CAD patients in a attempt to establish the role played by radionuclide methods in the diagnostic strategy is done. The perfusion cardiotropic radiopharmaceuticals used and the various methods of evaluating myocardial are discussed. Although 210 Tl-chloride is the most widely used myocardial perfusion agent, recently 99m Tc-MIBI is proposed as an alternative because of its advantages. Myocardial perfusion assessment is done by various techniques depending on the specific aim, each of them having its proper advantages and shortcomings. The inference is reached that regardless of the routine practical implementation of myocardial perfusion scintigraphy and comprehensive studies along this line in course, there are problems still not well enough clarified awaiting solution

  14. Tissue-engineered bone constructed in a bioreactor for repairing critical-sized bone defects in sheep.

    Science.gov (United States)

    Li, Deqiang; Li, Ming; Liu, Peilai; Zhang, Yuankai; Lu, Jianxi; Li, Jianmin

    2014-11-01

    Repair of bone defects, particularly critical-sized bone defects, is a considerable challenge in orthopaedics. Tissue-engineered bones provide an effective approach. However, previous studies mainly focused on the repair of bone defects in small animals. For better clinical application, repairing critical-sized bone defects in large animals must be studied. This study investigated the effect of a tissue-engineered bone for repairing critical-sized bone defect in sheep. A tissue-engineered bone was constructed by culturing bone marrow mesenchymal-stem-cell-derived osteoblast cells seeded in a porous β-tricalcium phosphate ceramic (β-TCP) scaffold in a perfusion bioreactor. A critical-sized bone defect in sheep was repaired with the tissue-engineered bone. At the eighth and 16th week after the implantation of the tissue-engineered bone, X-ray examination and histological analysis were performed to evaluate the defect. The bone defect with only the β-TCP scaffold served as the control. X-ray showed that the bone defect was successfully repaired 16 weeks after implantation of the tissue-engineered bone; histological sections showed that a sufficient volume of new bones formed in β-TCP 16 weeks after implantation. Eight and 16 weeks after implantation, the volume of new bones that formed in the tissue-engineered bone group was more than that in the β-TCP scaffold group (P bone improved osteogenesis in vivo and enhanced the ability to repair critical-sized bone defects in large animals.

  15. Goal-directed-perfusion in neonatal aortic arch surgery.

    Science.gov (United States)

    Cesnjevar, Robert Anton; Purbojo, Ariawan; Muench, Frank; Juengert, Joerg; Rueffer, André

    2016-07-01

    Reduction of mortality and morbidity in congenital cardiac surgery has always been and remains a major target for the complete team involved. As operative techniques are more and more standardized and refined, surgical risk and associated complication rates have constantly been reduced to an acceptable level but are both still present. Aortic arch surgery in neonates seems to be of particular interest, because perfusion techniques differ widely among institutions and an ideal form of a so called "total body perfusion (TBP)" is somewhat difficult to achieve. Thus concepts of deep hypothermic circulatory arrest (DHCA), regional cerebral perfusion (RCP/with cardioplegic cardiac arrest or on the perfused beating heart) and TBP exist in parallel and all carry an individual risk for organ damage related to perfusion management, chosen core temperature and time on bypass. Patient safety relies more and more on adequate end organ perfusion on cardiopulmonary bypass, especially sensitive organs like the brain, heart, kidney, liver and the gut, whereby on adequate tissue protection, temperature management and oxygen delivery should be visualized and monitored.

  16. Diagnostic accuracy of exercise thallium-201 single-photon emission computed tomography in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Larcos, G.; Gibbons, R.J.; Brown, M.L.

    1991-01-01

    Recent reports have proposed that abnormal apical or anterior wall perfusion with exercise thallium-201 imaging may increase diagnostic accuracy for disease of the left anterior descending artery in patients with left bundle branch block (LBBB). To evaluate these suggestions, 83 patients with LBBB who underwent thallium-201 single-photon emission computed tomography and coronary angiography within an interval of 3 months were retrospectively reviewed. There were 59 men and 24 women aged 33 to 84 years (mean 65). Myocardial perfusion to the apex, anterior wall and anterior septum were scored qualitatively by consensus of 2 experienced observers and by quantitative analysis in comparison with a normal data base. The sensitivity, specificity and accuracy of perfusion defects in these segments were then expressed according to angiographic findings. Significant stenosis of vessels within the left anterior descending artery territory was present in 38 patients. By receiver-operator characteristic analysis, a fixed or reversible defect within the apex by the qualitative method was the best criterion for coronary artery disease. However, although highly sensitive (79 and 85% by the qualitative and quantitative methods, respectively), an apical defect was neither specific (38 and 16%, respectively), nor accurate (57 and 46%, respectively). Perfusion abnormalities in the anterior wall and septum were also of limited diagnostic accuracy. Thus, modified interpretative criteria in patients with LBBB are not clinically useful in the assessment of left anterior descending artery disease

  17. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W.

    1990-01-01

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making

  18. Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies

    International Nuclear Information System (INIS)

    Murase, Kenya; Nanjo, Takafumi; Ii, Satoshi; Miyazaki, Shohei; Hirata, Masaaki; Sugawara, Yoshifumi; Kudo, Masayuki; Sasaki, Kousuke; Mochizuki, Teruhito

    2005-01-01

    The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation x 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current

  19. Tomographic myocardial perfusion scintigraphy in children with Kawasaki disease

    International Nuclear Information System (INIS)

    Spielmann, R.P.; Nienaber, C.A.; Hausdorf, G.; Montz, R.

    1987-01-01

    Myocardial infarction and stenotic coronary lesions are serious late complications in children with Kawasaki disease. For the noninvasive assessment of myocardial perfusion, dipyridamole-redistribution 201 Tl emission computed tomography (ECT) was performed in seven children (age 2 8/12-8 7/12 yr) 3-20 mo after the acute stage of the disease. In all patients, coronary aneurysms had been demonstrated by cross-sectional echocardiography. The scintigrams of six children showed no significant regional reduction of myocardial thallium uptake. These children had remained asymptomatic since the acute stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with documented myocardial infarction. For this patient, obstruction of corresponding coronary vessels was confirmed by contrast angiography. It is suggested, that 201 Tl ECT after dipyridamole-induced vasodilation may be used as a safe alternative to invasive coronary angiography for follow-up investigations in patients with Kawasaki disease

  20. Gray matter perfusion correlates with disease severity in ALS.

    Science.gov (United States)

    Rule, Randall R; Schuff, Norbert; Miller, Robert G; Weiner, Michael W

    2010-03-09

    The goal of this study is to determine if regional brain perfusion, as measured by arterial spin labeling (ASL) MRI, is correlated with clinical measures of amyotrophic lateral sclerosis (ALS) disease severity. The presence of such a relationship would indicate a possible role for ASL perfusion as a marker of disease severity and upper motor neuron involvement in ALS. Disease severity was assessed in 16 subjects with ALS (age 54 +/- 11) using the Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS) and the pulmonary function measure, forced vital capacity (FVC). Upper motor neuron involvement was assessed by testing rapid tapping of the fingers and feet. Magnetic resonance perfusion images were coregistered with structural T1-weighted MRI, corrected for partial volume effects using the structural images and normalized to a study-specific atlas. Correlations between perfusion and ALS disease severity were analyzed, using statistical parametric mapping, and including age as a factor. Analyses were adjusted for multiple clusters. ALS severity, as measured by the ALSFRS and FVC, was correlated with gray matter perfusion. This correlation was predominantly observed in the hemisphere contralateral to the more affected limbs. ALSFRS scores correlated with perfusion in the contralateral frontal and parietal lobe (p frontal lobe (p frontal lobe (p Upper motor neuron involvement, as measured by rapid finger tapping, correlated bilaterally with perfusion in the middle cingulate gyrus (p < 0.001). Amyotrophic lateral sclerosis (ALS) severity is correlated with brain perfusion as measured by arterial spin labeling (ASL) perfusion. This correlation appears to be independent of brain atrophy. ASL perfusion may be a useful tool for monitoring disease progression and assessing treatment effects in ALS.