WorldWideScience

Sample records for reversed-phase hplc method

  1. Development of Reverse-Phase HPLC Method for Simultaneous ...

    African Journals Online (AJOL)

    Erah

    Purpose: To develop a simple, sensitive and rapid reverse phase HPLC method for the simultaneous analysis of metoprolol succinate and hydrochlorothiazide in a solid dosage form. Methods: The .... Extraction was carried out three times with.

  2. Validated Reverse Phase HPLC Method for the Determination of Impurities in Etoricoxib

    Directory of Open Access Journals (Sweden)

    S. Venugopal

    2011-01-01

    Full Text Available This paper describes the development of reverse phase HPLC method for etoricoxib in the presence of impurities and degradation products generated from the forced degradation studies. The drug substance was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation of etoricoxib was observed under base and oxidation environment. The drug was found stable in other stress conditions studied. Successful separation of the drug from the process related impurities and degradation products were achieved on zorbax SB CN (250 x 4.6 mm 5 μm particle size column using reverse phase HPLC method. The isocratic method employed with a mixture of buffer and acetonitrile in a ratio of 60:40 respectively. Disodium hydrogen orthophosphate (0.02 M is used as buffer and pH adjusted to 7.20 with 1 N sodium hydroxide solution. The HPLC method was developed and validated with respect to linearity, accuracy, precision, specificity and ruggedness.

  3. Gradient Scouting in Reversed-Phase HPLC Revisited

    Science.gov (United States)

    Alcazar, A.; Jurado, J. M.; Gonzalez, A. G.

    2011-01-01

    Gradient scouting is the best way to decide the most suitable elution mode in reversed-phase high-performance liquid chromatography (RP-HPLC). A simple rule for this decision involves the evaluation of the ratio [delta]t/t[subscript G] (where [delta]t is the difference in the retention time between the last and the first peak and t[subscript G] is…

  4. Reverse-phase HPLC analysis of human alpha crystallin.

    Science.gov (United States)

    Swamy, M S; Abraham, E C

    1991-03-01

    A rapid and highly sensitive reverse-phase HPLC (RP-HPLC) method was used to separate crystallin subunits from human alpha crystallin. Three distinct peaks were separated; by electrophoretic and immunological analyses the first and second peaks were identified as alpha B and alpha A respectively. On the other hand, peak 3 appeared to be a modified form of alpha crystallin. The ratio of alpha A and alpha B proteins was 3:1 in 1 day old lenses which gradually changed to 2:1 in 17 year old lenses and to 1:1 in the 50 and 82 year old whole lenses and 82 year old lens cortex, with a concomitant increase in the modified alpha, suggesting that alpha A subunits are relatively more involved in aggregation. Analysis of the 82 year old lens nucleus also supported this conclusion. The RP-HPLC analysis of the HMW aggregate fraction showed substantial enrichment of the modified alpha. The alpha A and alpha B subunits independently reassociated to form polymeric alpha crystallin whereas the modified alpha reassociated to form HMW aggregates as shown by molecular sieve HPLC. Hence it appears that the HMW aggregate peak was constituted by modified alpha crystallin. Only in the peak 3 material the 280 nm absorbance was about 2-fold higher than what was expected from the actual protein content. The data suggest that the changes induced by post-translational modifications may have some role in the formation of modified alpha. The present RP-HPLC method is useful in separating these modified alpha from the unmodified alpha A and alpha B subunits.

  5. Stability Indicating Reverse Phase HPLC Method for Estimation of Rifampicin and Piperine in Pharmaceutical Dosage Form.

    Science.gov (United States)

    Shah, Umang; Patel, Shraddha; Raval, Manan

    2018-01-01

    High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. The use of dihexyldithiocarbamate in reverse-phase HPLC of metal chelates

    Science.gov (United States)

    Fatimah, S. S.; Bahti, H. H.; Hastiawan, I.; Permanasari, A.

    2018-05-01

    Dialkyldithiocarbamates have long been used as chelating agents in reverse-phase HPLC of transition metals. In the previous study, an alkyl homolog of this type of ligand, namely dihexyldithiocarbamate (DHDTC), was synthesized and characterized. The use of this particular ligand in the revese-phase HPLC of some selected transition metal ions is now reported for the first time. The mobile phase comprising of the flow rate and of the detection, in the separation of the metal chelates of Cd (II), Fe (III), Cu (II), and Co (III), were investigated on a C-18 column. The results showed that dihexylditiocarbamate could be used for separating Cd (II), Fe(III), Cu(II), and Co(III). Therefore, it could be used in simultaneous analysis.

  7. Estimation of Ziprasidone Hydrochloride Monohydrate in Bulk and Capsules by Reverse Phase HPLC

    Directory of Open Access Journals (Sweden)

    B. Sudha Rani

    2006-01-01

    Full Text Available A reverse phase HPLC method is described for the determination of Ziprasidone HCl mono hydrate in bulk and pharmaceutical dosage forms. Chromatography was carried out on an ODS C18 column using a mixture of methanol and phosphate buffer (55:45v/v as the mobile phase at a flow rate of 1mL/min. Detection was carried out at 314nm. The retension time of the drug was 4.522 min. The method produced linear responses in the concentration range of 0.5-30 μg /mL of Ziprasidone HCl mono hydrate.The method was found to be applicable for determination of the drug in capsules.

  8. Development and validation of reversed-phase HPLC gradient method for the estimation of efavirenz in plasma.

    Directory of Open Access Journals (Sweden)

    Shweta Gupta

    Full Text Available Efavirenz is an anti-viral agent of non-nucleoside reverse transcriptase inhibitor category used as a part of highly active retroviral therapy for the treatment of infections of human immune deficiency virus type-1. A simple, sensitive and rapid reversed-phase high performance liquid chromatographic gradient method was developed and validated for the determination of efavirenz in plasma. The method was developed with high performance liquid chromatography using Waters X-Terra Shield, RP18 50 x 4.6 mm, 3.5 μm column and a mobile phase consisting of phosphate buffer pH 3.5 and Acetonitrile. The elute was monitored with the UV-Visible detector at 260 nm with a flow rate of 1.5 mL/min. Tenofovir disoproxil fumarate was used as internal standard. The method was validated for linearity, precision, accuracy, specificity, robustness and data obtained were statistically analyzed. Calibration curve was found to be linear over the concentration range of 1-300 μg/mL. The retention times of efavirenz and tenofovir disoproxil fumarate (internal standard were 5.941 min and 4.356 min respectively. The regression coefficient value was found to be 0.999. The limit of detection and the limit of quantification obtained were 0.03 and 0.1 μg/mL respectively. The developed HPLC method can be useful for quantitative pharmacokinetic parameters determination of efavirenz in plasma.

  9. Development and validation of a rapid reversed-phase HPLC method for the determination of the non-nucleoside reverse transcriptase inhibitor dapivirine from polymeric nanoparticles.

    Science.gov (United States)

    das Neves, José; Sarmento, Bruno; Amiji, Mansoor M; Bahia, Maria Fernanda

    2010-06-05

    The objective of this work was to develop and validate a rapid reversed-phase (RP) high-performance liquid chromatography (HPLC) method for the in vitro pharmaceutical characterization of dapivirine-loaded polymeric nanoparticles. Chromatographic runs were performed on a RP C18 column with a mobile phase comprising acetonitrile-0.5% (w/v) triethanolamine solution in isocratic mode (80:20, v/v) at a flow rate of 1 ml/min. Dapivirine was detected at a wavelength of 290 nm. The method was shown to be specific, linear in the range of 1-50 microg/ml (R(2)=0.9998), precise at the intra-day and inter-day levels as reflected by the relative standard deviation values (less than 0.85%), accurate (recovery rate of 100.17+/-0.35%), and robust to changes in the mobile phase and column brand. The detection and quantitation limits were 0.08 and 0.24 microg/ml, respectively. The method was successfully used to determine the loading capacity and association efficiency of dapivirine in poly(lactic-co-glycolic acid)-based nanoparticles and its in vitro release. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. A Simple and Validated Reverse Phase HPLC Methodfor the Determination of Rabeprazole inPharmaceutical Dosage Forms

    Directory of Open Access Journals (Sweden)

    Uma Mahesh Karra

    2010-01-01

    Full Text Available A simple and rapid reverse phase high performance liquid chromatography (RP-HPLC method was developed and validated for quantitative determination of rabeprazole in bulk drug samples and formulations. Rabeprazole was analyzed by using reverse phase LC-GC column (Inertsil ODS, 4.6 mm x 25 cm, 5 microns, with mobile phase consisting of methanol: water (78:22 v/v. The flow rate was set 1.0 mL/min and analysis was performed at wavelength 288 nm using Photo Diode Array (PDA detector at ambient temperature. The method was validated and stability studies were conducted under different conditions. The retention time for rabeprazole was around 4.12 minutes. The calibration curves were linear (r≥0.9998 over a concentration range from 20.0 to 80.0 μg/mL. Limit of detection (LOD and Limit of quantitation (LOQ were 8 ng/mL and 24 ng/mL respectively. The developed method was successfully applied to estimate the amount of rabeprazole in tablet formulations.

  11. A Standard Addition Method to Assay the Concentration of Biologically Interesting Polyphenols in Grape Berries by Reversed-Phase HPLC

    Directory of Open Access Journals (Sweden)

    Serkos A. Haroutounian

    2007-09-01

    Full Text Available A reversed-phase HPLC method which allows the simultaneous assay of (+- catechin, (–-epicatechin, trans-resveratrol, quercetin and quercetin glycosides in grape berries is described. Kromasil 100 served as stationary phase and a gradient of acetic acid, water and methanol was used. The analytical run requires 42 min for complete sample elution. Satisfactory peak resolution was achieved following a novel extraction process and direct injection of a 20 μL sample. The method was used for the analyses of eighteen samples. Linearities were in the range of 0.98 to 0.999 regression coefficient, for all phenolics, while detection limits ranged from 30 μg mL–1 for trans-resveratrol to 1.5 mg mL–1 for (+-catechin. Recoveries ranged from 95.1 to 98.7% while the method provided good precision, with standard deviations between 3.5 and 6.1%, n=5.

  12. Arsenic-containing fatty acids and hydrocarbons in marine oils - Determination using reversed-phase HPLC-ICP-MS and HPLC-qTOF-MS

    DEFF Research Database (Denmark)

    Sele, Veronika; Sloth, Jens Jørgen; Holmelid, Bjarte

    2014-01-01

    ; dimethylarsinate (DMA), triphenylarsinoxide (Ph3AsO) and a synthesized arsenic-containing hydrocarbon (AsHC) (dimethylarsinoyl nonadecane; C21H43AsO). The observed variation in signal intensity for arsenic during the gradient elution profile in reversed-phase HPLC was compensated for by determining the time...

  13. A rapid hydrolysis method and DABS-Cl derivatization for complete amino acid analysis of octreotide acetate by reversed phase HPLC.

    Science.gov (United States)

    Akhlaghi, Yousef; Ghaffari, Solmaz; Attar, Hossein; Alamir Hoor, Amir

    2015-11-01

    Octreotide as a synthetic cyclic octapeptide is a somatostatin analog with longer half-life and more selectivity for inhibition of the growth hormone. The acetate salt of octreotide is currently used for medical treatment of somatostatin-related disorders such as endocrine and carcinoid tumors, acromegaly, and gigantism. Octreotide contains both cysteine and tryptophan residues which make the hydrolysis part of its amino acid analysis procedure very challenging. The current paper introduces a fast and additive-free method which preserves tryptophan and cysteine residues during the hydrolysis. Using only 6 M HCl, this hydrolysis process is completed in 30 min at 150 °C. This fast hydrolysis method followed by pre-column derivatization of the released amino acids with 4-N,N-dimethylaminoazobenzene-4'-sulfonyl chloride (DABS-Cl) which takes only 20 min, makes it possible to do the complete amino acid analysis of an octreotide sample in a few hours. The highly stable-colored DABS-Cl derivatives can be detected in 436 nm in a reversed phase chromatographic system, which eliminates spectral interferences to a great extent. The amino acid analysis of octreotide acetate including hydrolysis, derivatization, and reversed phase HPLC determination was validated according to International Conference of Harmonization (ICH) guidelines.

  14. Solid-Phase Extraction and Reverse-Phase HPLC: Application to Study the Urinary Excretion Pattern of Benzophenone-3 and its Metabolite 2,4-Dihydroxybenzophenone in Human Urine

    Directory of Open Access Journals (Sweden)

    Helena Gonzalez

    2008-01-01

    Full Text Available Background Benzophenone-3 (BZ-3 is a common ultraviolet (UV absorbing compound in sunscreens. It is the most bioavailable species of all UV-absorbing compounds after topical application and can be found in plasma and urine. Objectives The aim of this study was to develop a reverse-phase high performance liquid chromatography (HPLC method for determining the amounts BZ-3 and its metabolite 2,4-dihydroxybenzophenone (DHB in human urine. The method had to be suitable for handling a large number of samples. It also had to be rapid and simple, but still sensitive, accurate and reproducible. The assay was applied to study the urinary excretion pattern after repeated whole-body applications of a commercial sunscreen, containing 4% BZ-3, to 25 healthy volunteers. Methods Each sample was analyzed with regard to both conjugated/non-conjugated BZ-3 and conjugated/non-conjugated DHB, since both BZ-3 and DHB are extensively conjugated in the body. Solid-phase extraction (SPE with C8 columns was followed by reverse-phase HPLC. For separation a Genesis C18 column was used with an acethonitrile-water mobile phase and the UV-detector was set at 287 nm. Results The assay was linear r 2 > 0.99, with detection limits for BZ-3 and DHB of 0.01 µmol L -1 and 0.16 µmol L -1 respectively. Relative standard deviation (RSD was less than 10% for BZ-3 and less than 13% for DHB. The excretion pattern varied among the human volunteers; we discerned different patterns among the individuals. Conclusions The reverse-phase HPLC assay and extraction procedures developed are suitable for use when a large number of samples need to be analyzed and the method fulfilled our objectives. The differences in excretion pattern may be due to differences in enzyme activity but further studies, especially about genetic polymorphism, need to be performed to verify this finding.

  15. Extraction and determination of biogenic amines in fermented sausages and other meat products using reversed-phase-HPLC.

    Science.gov (United States)

    Straub, B; Schollenberger, M; Kicherer, M; Luckas, B; Hammes, W P

    1993-09-01

    A convenient method is described for the analysis of biogenic amines (BA) by means of reversed-phase-HPLC. The method is characterized by multi-channel UV detection (diodearray), subsequent post-column derivatization with o-phthaldialdehyde and 3-mercaptopropionic acid, and fluorescence detection. For the analysis of meat products and especially fermented sausages an optimized perchloric acid extraction process was introduced to determine putrescine, cadaverine, histamine, tyramine and 2-phenylethylamine. BA recoveries from meat ranged between 96 and 113% with a detection limit for amines of 0.5 mg/kg.

  16. Determination of the Trans-resveratrol content of Champagne wines by reversed-phase HPLC

    Directory of Open Access Journals (Sweden)

    Philippe Jeandet

    2006-06-01

    Full Text Available Levels of trans-resveratrol in Champagne wines were determined by the use of reversed-phase HPLC with UV and fluorometric detection after liquid-liquid extraction with ethyl acetate. Resveratrol concentrations in Champagne wines range from 20 to 77 μg/L except for the Champagne rosé in which resveratrol reaches several hundred micrograms per litre. The resveratrol content of Champagne wines was also shown to decrease with aging on lees.

  17. Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis

    Directory of Open Access Journals (Sweden)

    Moussa Yabré

    2018-05-01

    Full Text Available The greening of analytical methods has gained increasing interest in the field of pharmaceutical analysis to reduce environmental impacts and improve the health safety of analysts. Reversed-phase high-performance liquid chromatography (RP-HPLC is the most widely used analytical technique involved in pharmaceutical drug development and manufacturing, such as the quality control of bulk drugs and pharmaceutical formulations, as well as the analysis of drugs in biological samples. However, RP-HPLC methods commonly use large amounts of organic solvents and generate high quantities of waste to be disposed, leading to some issues in terms of ecological impact and operator safety. In this context, greening HPLC methods is becoming highly desirable. One strategy to reduce the impact of hazardous solvents is to replace classically used organic solvents (i.e., acetonitrile and methanol with greener ones. So far, ethanol has been the most often used alternative organic solvent. Others strategies have followed, such as the use of totally aqueous mobile phases, micellar liquid chromatography, and ionic liquids. These approaches have been well developed, as they do not require equipment investments and are rather economical. This review describes and critically discusses the recent advances in greening RP-HPLC methods dedicated to pharmaceutical analysis based on the use of alternative solvents.

  18. Application of Statistical Thermodynamics To Predict the Adsorption Properties of Polypeptides in Reversed-Phase HPLC.

    Science.gov (United States)

    Tarasova, Irina A; Goloborodko, Anton A; Perlova, Tatyana Y; Pridatchenko, Marina L; Gorshkov, Alexander V; Evreinov, Victor V; Ivanov, Alexander R; Gorshkov, Mikhail V

    2015-07-07

    The theory of critical chromatography for biomacromolecules (BioLCCC) describes polypeptide retention in reversed-phase HPLC using the basic principles of statistical thermodynamics. However, whether this theory correctly depicts a variety of empirical observations and laws introduced for peptide chromatography over the last decades remains to be determined. In this study, by comparing theoretical results with experimental data, we demonstrate that the BioLCCC: (1) fits the empirical dependence of the polypeptide retention on the amino acid sequence length with R(2) > 0.99 and allows in silico determination of the linear regression coefficients of the log-length correction in the additive model for arbitrary sequences and lengths and (2) predicts the distribution coefficients of polypeptides with an accuracy from 0.98 to 0.99 R(2). The latter enables direct calculation of the retention factors for given solvent compositions and modeling of the migration dynamics of polypeptides separated under isocratic or gradient conditions. The obtained results demonstrate that the suggested theory correctly relates the main aspects of polypeptide separation in reversed-phase HPLC.

  19. Chiral chromatography studies of chemical behavior of cinacalcet on polysaccharide chiral reversed-phase HPLC stationary phases.

    Science.gov (United States)

    Dousa, Michal; Brichác, Jirí

    2012-01-01

    A rapid HPLC method for the analytical resolution of cinacalcet enantiomers was developed. Four chiral columns (two amylose and two cellulose type) were evaluated in RP systems. Excellent enantioseparation with a resolution of more than 6 was achieved on Chiralpak AY (amylose 5-chloro-2-methylphenylcarbamate chiral stationary phase) using 10 mM triethylamine (pH 8.0)-acetonitrile (40 + 60, v/v) mobile phase. Validation of the HPLC method, including linearity, LOD, LOQ, precision, accuracy, and selectivity, was performed according to the International Conference on Harmonization guidelines. The method was successfully applied for the determination of (S)-cinacalcet in enantiopure active pharmaceutical ingredient (R)-cinacalcet.

  20. Comparison of Separation of Seed Oil Triglycerides Containing Isomeric Conjugated Octadecatrienoic Acid Moieties by Reversed-Phase HPLC

    OpenAIRE

    Anh Van Nguyen; Victor Deineka; Lumila Deineka; Anh Vu Thi Ngoc

    2017-01-01

    Relative retention analysis and increment approach were applied for the comparison of triglycerides (TGs) retention of a broad set of plant seed oils with isomeric conjugated octadecatrienoic acids (CLnA) by reversed-phase HPLC for “propanol-2-acetonitrile” mobile phases and Kromasil 100-5C18 stationary phase with diode array detection (DAD) and mass spectrometric (MS) detection. The subjects of investigation were TGs of seed oils: Calendula officinalis, Catalpa ovata, Jacaranda mimosifolia, ...

  1. Validated RP-HPLC Method for Quantification of Phenolic ...

    African Journals Online (AJOL)

    Purpose: To evaluate the total phenolic content and antioxidant potential of the methanol extracts of aerial parts and roots of Thymus sipyleus Boiss and also to determine some phenolic compounds using a newly developed and validated reversed phase high performance liquid chromatography (RP-HPLC) method.

  2. Reversed Phase Column HPLC-ICP-MS Conditions for Arsenic Speciation Analysis of Rice Flour.

    Science.gov (United States)

    Narukawa, Tomohiro; Matsumoto, Eri; Nishimura, Tsutomu; Hioki, Akiharu

    2015-01-01

    New measurement conditions for arsenic speciation analysis of rice flour were developed using HPLC-ICP-MS equipped with a reversed phase ODS column. Eight arsenic species, namely, arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), trimethylarsine oxide (TMAO), tetramethylarsonium (TeMA), arsenobetaine (AsB) and arsenocholine (AsC), were separated and determined under the proposed conditions. In particular, As(III) and MMAA and DMAA and AsB were completely separated using a newly proposed eluent containing ammonium dihydrogen phosphate. Importantly, the sensitivity changes, in particular those of As(V) and As(III) caused by coexisting elements and by complex matrix composition, which had been problematical in previously reported methods, were eliminated. The new eluent can be applied to C8, C18 and C30 ODS columns with the same effectiveness and with excellent repeatability. The proposed analytical method was successfully applied to extracts of rice flour certified reference materials.

  3. Reversed Phase HPLC-DAD Profiling of Carotenoids, Chlorophylls and Phenolic Compounds in Adiantum capillus-veneris Leaves

    OpenAIRE

    Zeb, Alam; Ullah, Fareed

    2017-01-01

    Adiantum capillus-veneris is important endangered fern species with several medicinal properties. In this study, the leaves samples were extracted and separated using reversed phase HPLC with DAD for carotenoids, chlorophylls and phenolic compounds. Separation of carotenoids and chlorophylls were carried out using a tertiary gradient system of water, MTBE and methanol-water, while a binary gradient system of methanol-water-acetic acid was used for phenolic profiling. Results revealed eight ca...

  4. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    Science.gov (United States)

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  5. Validation and Application of a New Reversed Phase HPLC Method for In Vitro Dissolution Studies of Rabeprazole Sodium in Delayed-Release Tablets

    Directory of Open Access Journals (Sweden)

    Md. Saddam Nawaz

    2013-01-01

    Full Text Available The purpose of this study was to develop and validate a new reversed phase high performance liquid chromatographic (RP-HPLC method to quantify in vitro dissolution assay of rabeprazole sodium in pharmaceutical tablet dosage form. Method development was performed on C 18, 100×4.6 mm ID, and 10 μm particle size column, and injection volume was 20 μL using a diode array detector (DAD to monitor the detection at 280 nm. The mobile phase consisted of buffer: acetonitrile at a ratio of 60 : 40 (v/v, and the flow rate was maintained at 1.0 mL/min. The method was validated in terms of suitability, linearity, specificity, accuracy, precision, stability, and sensitivity. Linearity was observed over the range of concentration 0.05–12.0 μg/mL, and the correlation coefficient was found excellent >0.999. The method was specific with respect to rabeprazole sodium, and the peak purity was found 99.99%. The method was precise and had relative standard deviations (RSD less than 2%. Accuracy was found in the range of 99.9 to 101.9%. The method was robust in different variable conditions and reproducible. This proposed fast, reliable, cost-effective method can be used as quality control tool for the estimation of rabeprazole sodium in routine dissolution test analysis.

  6. Arsenic-containing fatty acids and hydrocarbons in marine oils - determination using reversed-phase HPLC-ICP-MS and HPLC-qTOF-MS.

    Science.gov (United States)

    Sele, Veronika; Sloth, Jens J; Holmelid, Bjarte; Valdersnes, Stig; Skov, Kasper; Amlund, Heidi

    2014-04-01

    Arsenolipids are the major arsenic species present in marine oils. Several structures of arsenolipids have been elucidated the last 5 years, demonstrating the chemical complexity of this trace element in the marine environment. Several commercial fish oils and marine oils, ranging in total arsenic concentrations from 1.6 to 12.5 mg kg(-1) oil, were analyzed for arsenolipids using reversed-phase high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). The arsenolipids were quantified using three different arsenic-containing calibration standards; dimethylarsinate (DMA), triphenylarsinoxide (Ph₃AsO) and a synthesized arsenic-containing hydrocarbon (AsHC) (dimethylarsinoyl nonadecane; C₂₁H₄₃AsO). The observed variation in signal intensity for arsenic during the gradient elution profile in reversed-phase HPLC was compensated for by determining the time-resolved response factors for the arsenolipids. Isotopes of germanium ((74)Ge) and indium ((115)In) were suited as internal standards for arsenic, and were used for verification of the arsenic signal response factors during the gradient elution. Dimethylarsinate was the most suitable calibration standard for the quantification of arsenolipids, with recoveries between 91% and 104% compared to total arsenic measurements in the same extracts. A range of marine oils was investigated, including oils of several fish species, cod liver and seal, as well as three commercial fish oils. The AsHCs - C₁₇H₃₈AsO, C₁₉H₄₂AsO and C₂₃H₃₈AsO - were identified as the major arsenolipids in the extracts of all oils by HPLC coupled with quadrupole time-of-flight mass spectrometry (qTOF-MS). Minor amounts of two arsenic-containing fatty acids (AsFAs) (C₂₃H₃₈AsO₃ and C₂₄H₃₈AsO₃) were also detected in the oils. The sum of the AsHCs and the AsFAs determined in the present study accounted for 17-42% of the total arsenic in the oils

  7. [Simultaneous Determination of Three Kinds of Effective Constituents in Cannabis Plants by Reversed-phase HPLC].

    Science.gov (United States)

    Fu, Q; Shu, Z; Deng, K; Luo, X; Zeng, C G

    2016-08-01

    To establish a high performance liquid chromatographic (HPLC) method for simultaneous determination of three effective constituents, including tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in Cannabis plants. A C₁₈ column was used in this study, and acetonitrile-phosphate buffer (0.015 mol/L KH₂PO₄) was used as mobile phase at a flow rate of 1.0 mL/min. At a detection wavelength of 220 mm, UV absorption spectra were collected at the wavelength range of 190-400 nm, and the spectra and retention time were counted as qualitative evidence. THC, CBD and CBN could be well separated by this method. Three components had good linear relationship in the range of 0.4-40 μg/mL ( R ²≥0.999 3). The recoveries were over 87%. The limits of detection were 1.8 ng, 2.0 ng and 1.3 ng, respectively. The relative standard deviation (RSD) were less than 5% for both inter-day and intra-day precisions. Reversed-phase HPLC method is simple, rapid and accurate, and it is suitable for the qualitative and quantitative detection of THC, CBD and CBN in Cannabis plants. Copyright© by the Editorial Department of Journal of Forensic Medicine

  8. A Stability Indicating HPLC Method for the Determination of ...

    African Journals Online (AJOL)

    Erah

    stability indicating reverse phase HPLC method for estimating meloxicam (MLX) in bulk ... acetonitrile-water-glacial acetic acid [55:40:5 (% v/v)] at a flow rate of 1ml/min and detection wavelength .... pore and degassed before use. ... determined to assess the effect of small but ... deviation, the standard error of slope, and the.

  9. Method Development for the Analysis of Pharmaceuticals with Acethylcholinesterase Activity in Water Using HPLC-DAD and Solid Phase Extraction

    Directory of Open Access Journals (Sweden)

    Samuel Budi Wardhana

    2014-03-01

    Full Text Available An SPE followed by HPLC-DAD method with ion pair chromatography technique to analyze pharmaceuticals with acethylcholinesterase activity including pyridostigmine (PYR, galathamine (GAL, neostigmine (NEO, eserine (ESE, and donepezil (DON in water samples was developed. Acetylcholinesterase (AChE inhibitors have been used to treat less severe dementias such as Alzheimer’s disease. Chromatographic separation was achieved using reversed-phase SymmetryShield column using gradient system with mobile phase consisting of H2O/ACN (99:1, v/v as mobile phase A with 10 mM sodium 1-hexanesulfonate and 0.1% acetic acid (HAc. The HPLC/DAD method was linear between concentrations of 5 to 100 ng/μL. The IDL and IQL ranged from 0.50 to 1.25 ng/μL and 1.5 to 3.0 ng/μL, respectively. SPE was used to extract and clean up the target substances in spiked pure water, tap water, and wastewater samples. The application of extraction method of 5 target substances in wastewater sample was divided into 2 parts: Oasis WCX (6 mL, 500 mg for PYR and Oasis HLB (6 mL, 200 mg for GAL, NEO, ESE and DON. The developed SPE and HPLC/DAD method is applicable for quantification of the 5 target substances in water samples in a concentration range > 50 µg/L and assumable lower for DON (> 25 µg/L.

  10. Benefits and Limitations of Lab-on-a-Chip Method over Reversed-Phase High-Performance Liquid Chromatography Method in Gluten Proteins Evaluation

    Directory of Open Access Journals (Sweden)

    Dragan Živančev

    2015-01-01

    Full Text Available RP-HPLC (reversed-phase high-performance liquid chromatography is widely used to determine the amounts of the different gluten protein types. However, this method is time-consuming, especially at early stages of wheat breeding, when large number of samples needs to be analyzed. On the other hand, LoaC (Lab-on-a-Chip technique has the potential for a fast, reliable, and automatable analysis of proteins. In the present study, benefits and limitations of Lab-on-a-Chip method over RP-HPLC method in gluten proteins evaluation were explored in order to determine in which way LoaC method should be improved in order to make its results more compliant with the results of RP-HPLC method. Strong correlation (P≤0.001 was found between numbers of HMW glutenin peaks determined by LoaC and RP-HPLC methods. Significant correlations (P≤0.05 were obtained between percentages of HMW and LMW glutenin subunits calculated with regard to total HMW + LMW area. Even more significant correlation (P≤0.001 was found when percentages of individual HMW areas were calculated with regard to total HMW. RP-HPLC method showed superiority in determination of gliadins since larger number and better resolution of gliadin peaks were obtained by this method.

  11. A NEW HPLC METHOD FOR SEPARATION OF PHYTOPLANKTON PIGMENTS IN NATURAL SAMPLES

    Science.gov (United States)

    A new high-performance liquid chromatographic (HPLC) method was developed to analyze, in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a reverse-phase amide C16 (RP-amide C16) column and an elution gradient o...

  12. Simultaneous quantification of porcine myocardial adenine nucleotides and creatine phosphate by ion-pair reverse-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Cordis, G.A.; Das, D.K.

    1987-01-01

    In order to follow the energy metabolism and the levels of high-energy phosphate compounds in porcine myocardium subjected to ischemic insult, it was necessary to develop a high-performance liquid chromatography (HPLC) method where creatine phosphate (CP) and the adenine nucleotides could be measured simultaneously in a single run. Currently available ion-pair reverse-phase HPLC methods require a separate injection with a change in wavelength and mobile phase in order to measure the creatine phosphate, while baseline separation of AMP is lacking. The ion-exchange HPLC method includes a simultaneous determination, but the baseline drifts due to the gradient and baseline separation of AMP is not achieved. In the following ion-pair reverse-phase HPLC method, simultaneous measurements of porcine myocardial adenine nucleotides and creatine phosphate were achieved along with a stable baseline and homogeneous baseline separation of each measured compound, allowing accurate quantification

  13. Development of Direct Reversed-Phase High Performance liquid chromatographic method for quantitative determination of gabapentin in pharmaceutical dosage

    International Nuclear Information System (INIS)

    Hassan, W.; Zaman, B.; Rahman, S.; Rahman, A.U.; Ali, N.; Mohammadzai, I.U.

    2012-01-01

    The objective of the present work was to develop and validate a rapid analytical method for quantitative determination of Gabapentin in pharmaceutical dosage tablets and capsules. An accurate, simple, and sensitive reversed-phase high performance liquid chromatographic (HPLC) method, UV detection at 215 nm and flow rate at 1.0 ml/min has been developed. Isocratic elution was used instead of gradient elution to reduce the time and cost of serial analysis. The mobile phase was a mixture of water and methanol (HPLC grade). The retention time (Rt) of Gabapentin was 4.681 +- 0.013 minutes. Recovery, Precision, accuracy, and linearity were determined for the stated method. The calibration curve was linear and the correlation coefficient was 0.9996. There was no chromatographic interference from other excipients present in dosage form. The method was validated appropriately and successfully used for determination of Gabapentin in Pharmaceutical formulations. (author)

  14. Simultaneous separation and analysis of water- and fat-soluble vitamins on multi-modal reversed-phase weak anion exchange material by HPLC-UV.

    Science.gov (United States)

    Dabre, Romain; Azad, Nazanin; Schwämmle, Achim; Lämmerhofer, Michael; Lindner, Wolfgang

    2011-04-01

    Several methods for the separation of vitamins on HPLC columns were already validated in the last 20 years. However, most of the techniques focus on separating either fat- or water-soluble vitamins and only few methods are intended to separate lipophilic and hydrophilic vitamins simultaneously. A mixed-mode reversed-phase weak anion exchange (RP-WAX) stationary phase was developed in our laboratory in order to address such mixture of analytes with different chemical characteristics, which are difficult to separate on standard columns. The high versatility in usage of the RP-WAX chromatographic material allowed a baseline separation of ten vitamins within a single run, seven water-soluble and three fat-soluble, using three different chromatographic modes: some positively charged vitamins are eluted in ion exclusion and ion repulsion modes whereas the negatively charged molecules are eluted in the ion exchange mechanism. The non-charged molecules are eluted in a classical reversed-phase mode, regarding their polarities. The method was validated for the vitamin analysis in tablets, evaluating selectivity, robustness, linearity, accuracy, and precision. The validated method was finally employed for the analysis of the vitamin content of some commercially available supplement tablets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    Science.gov (United States)

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  16. Reversed Phase HPLC-DAD Profiling of Carotenoids, Chlorophylls and Phenolic Compounds in Adiantum capillus-veneris Leaves

    Science.gov (United States)

    Zeb, Alam; Ullah, Fareed

    2017-04-01

    Adiantum capillus-veneris is important endangered fern species with several medicinal properties. In this study, the leaves samples were extracted and separated using reversed phase HPLC with DAD for carotenoids, chlorophylls and phenolic compounds. Separation of carotenoids and chlorophylls were carried out using a tertiary gradient system of water, MTBE and methanol-water, while a binary gradient system of methanol-water-acetic acid was used for phenolic profiling. Results revealed eight carotenoids, four pheophytins and two chlorophylls. Lutein (806.0 µg/g), chlorophyll b' (410.0 µg/g), chlorophyll a (162.4 µg/g), 9'-Z-neoxanthin (142.8 µg/g) and all-E-violaxanthin (82.2 µg/g)) were present in higher amounts. The relatively high amounts of lutein may be one of the key indicator of beneficial antioxidant properties. The phenolic profile revealed a total of thirteen compounds, namely p-hydroxybenzoic acid, chlorogenic acid, caftaric acid, kaempferol glycosides, p-coumaric acid, rosmarinic acid, 5-caffeoylquinic acid, and quercetin glycosides. Kaempferol-3-sophorotrioside (58.7 mg/g), chlorogenic acid (28.5 mg/g), 5-O-caffeoylquinic acid (18.7 mg/g), coumaric acid (11.2 mg/g) and its derivative (33.1 mg/g) were present in high amounts. These results suggest that the reversed phase HPLC profiling of adiantum leaves provides a better understanding in to the actual composition of bioactive compounds, which may be responsible for possible medicinal properties. Adiantum leaves rich in important bioactive phytochemicals can be used as a potential source of nutraceuticals or as a functional food ingredient.

  17. Leukotriene B4 catabolism: quantitation of leukotriene B4 and its omega-oxidation products by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Shak, S

    1987-01-01

    LTB4 and its omega-oxidation products may be rapidly, sensitively, and specifically quantitated by the methods of solid-phase extraction and reversed-phase high-performance liquid chromatography (HPLC), which are described in this chapter. Although other techniques, such as radioimmunoassay or gas chromatography-mass spectrometry, may be utilized for quantitative analysis of the lipoxygenase products of arachidonic acid, only the technique of reversed-phase HPLC can quantitate as many as 10 metabolites in a single analysis, without prior derivatization. In this chapter, we also reviewed the chromatographic theory which we utilized in order to optimize reversed-phase HPLC analysis of LTB4 and its omega-oxidation products. With this information and a gradient HPLC system, it is possible for any investigator to develop a powerful assay for the potent inflammatory mediator, LTB4, or for any other lipoxygenase product of arachidonic acid.

  18. Reversed Phase HPLC-DAD Profiling of Carotenoids, Chlorophylls and Phenolic Compounds in Adiantum capillus-veneris Leaves

    Directory of Open Access Journals (Sweden)

    Alam Zeb

    2017-04-01

    Full Text Available Adiantum capillus-veneris is important endangered fern species with several medicinal properties. In this study, the leaves samples were extracted and separated using reversed phase HPLC with DAD for carotenoids, chlorophylls and phenolic compounds. Separation of carotenoids and chlorophylls were carried out using a tertiary gradient system of water, MTBE and methanol-water, while a binary gradient system of methanol-water-acetic acid was used for phenolic profiling. Results revealed eight carotenoids, four pheophytins, and two chlorophylls. Lutein (806.0 μg/g, chlorophyll b′ (410.0 μg/g, chlorophyll a (162.4 μg/g, 9′-Z-neoxanthin (142.8 μg/g and all-E-violaxanthin (82.2 μg/g were present in higher amounts. The relatively high amounts of lutein may be one of the key indicator of beneficial antioxidant properties. The phenolic profile revealed a total of 13 compounds, namely 4-hydroxybenzoic acid, chlorogenic acid, caftaric acid, kaempferol glycosides, p-coumaric acid, rosmarinic acid, 5-caffeoylquinic acid, and quercetin glycosides. Kaempferol-3-sophorotrioside (58.7 mg/g, chlorogenic acid (28.5 mg/g, 5-O-caffeoylquinic acid (18.7 mg/g, coumaric acid (11.2 mg/g, and its derivative (33.1 mg/g were present in high amounts. These results suggest that the reversed phase HPLC profiling of Adiantum leaves provides a better understanding in to the actual composition of bioactive compounds, which may be responsible for the potential medicinal properties. Adiantum leaves rich in important bioactive phytochemicals can be used as a possible source of nutraceuticals or as a functional food ingredient.

  19. Pellicular particles with spherical carbon cores and porous nanodiamond/polymer shells for reversed-phase HPLC.

    Science.gov (United States)

    Wiest, Landon A; Jensen, David S; Hung, Chuan-Hsi; Olsen, Rebecca E; Davis, Robert C; Vail, Michael A; Dadson, Andrew E; Nesterenko, Pavel N; Linford, Matthew R

    2011-07-15

    A new stationary phase for reversed-phase high performance liquid chromatography (RP HPLC) was created by coating spherical 3 μm carbon core particles in a layer-by-layer (LbL) fashion with poly(allylamine) (PAAm) and nanodiamond. Unfunctionalized core carbon particles were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and Raman spectroscopy. After LbL of PAAm and nanodiamond, which yields ca. 4 μm core-shell particles, the particles were simultaneously functionalized and cross-linked using a mixture of 1,2-epoxyoctadecane and 1,2,7,8-diepoxyoctane to obtain a mechanically stable C(18)/C(8) bonded outer layer. Core-shell particles were characterized by SEM, and their surface area, pore diameter, and volume were determined using the Brunauer-Emmett-Teller (BET) method. Short stainless steel columns (30 × 4.6 mm i.d.) were packed and the corresponding van Deemter plots obtained. The Supporting Information contains a MATLAB program used to fit the van Deemter data. The retentions of a suite of analytes were investigated on a conventional HPLC at various organic solvent compositions, pH values of mobile phases, including extreme pH values, and column temperatures. At 60 °C, a chromatogram of 2,6-diisopropylphenol showed 71,500 plates/m (N/m). Chromatograms obtained under acidic conditions (pH 2.7) of a mixture of acetaminophen, diazepam, and 2,6-diisopropylphenol and a mixture of phenol, 4-methylphenol, 2-chlorophenol, 4-chlorophenol, 4-bromophenol, and 1-tert-butyl-4-methylphenol are presented. Retention of amitriptyline, cholesterol, and diazinon at temperatures ranging from 35 to 80 °C and at pH 11.3 is reported. A series of five basic drugs was also separated at this pH. The stationary phase exhibits considerable hydrolytic stability at high pH (11.3) and even pH 13 over extended periods of time. An analysis run on a UHPLC with a "sandwich" injection

  20. A Validated Stability-Indicating HPLC Method for Simultaneous Determination of Amoxicillin and Enrofloxacin Combination in an Injectable Suspension

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available The combination of amoxicillin and enrofloxacin is a well-known mixture of veterinary drugs; it is used for the treatment of Gram-positive and Gram-negative bacteria. In the scientific literature, there is no high-performance liquid chromatography (HPLC-UV method for the simultaneous determination of this combination. The objective of this work is to develop and validate an HPLC method for the determination of this combination. In this regard, a new, simple and efficient reversed-phase HPLC method for simultaneous qualitative and quantitative determination of amoxicillin and enrofloxacin, in an injectable preparation with a mixture of inactive excipients, has been developed and validated. The HPLC separation method was performed using a reversed-phase (RP-C18e (250 mm × 4.0 mm, 5 μm column at room temperature, with a gradient mobile phase of acetonitrile and phosphate buffer containing methanol at pH 5.0, a flow rate of 0.8 mL/min and ultraviolet detection at 267 nm. This method was validated in accordance with the Food and Drug Administration (FDA and the International Conference on Harmonisation (ICH guidelines and showed excellent linearity, accuracy, precision, specificity, robustness, ruggedness, and system suitability results within the acceptance criteria. A stability-indicating study was also carried out and indicated that this method can also be used for purity and degradation evaluation of these formulations.

  1. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    Science.gov (United States)

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  2. Quantification of whey proteins by reversed phase-HPLC and effectiveness of mid-infrared spectroscopy for their rapid prediction in sweet whey.

    Science.gov (United States)

    Sturaro, Alba; De Marchi, Massimo; Masi, Antonio; Cassandro, Martino

    2016-01-01

    In the dairy industry, membrane filtration is used to reduce the amount of whey waste and, simultaneously, to recover whey proteins (WP). The composition of WP can strongly affect the filtration treatment of whey, and rapid determination of WP fractions would be of interest for dairy producers to monitor WP recovery. This study aimed to develop mid-infrared spectroscopy (MIRS) prediction models for the rapid quantification of protein in sweet whey, using a validated rapid reversed phase (RP)-HPLC as a reference method. Quantified WP included α-lactalbumin (α-LA), β-lactoglobulin (β-LG) A and B, bovine serum albumin, caseinomacropeptides, and proteose peptone. Validation of RP-HPLC was performed by calculating the relative standard deviation (RSD) in repeatability and reproducibility tests for WP retention time and peak areas. Samples of liquid whey (n=187) were analyzed by RP-HPLC and scanned through MIRS to collect spectral information (900 to 4,000 cm(-1)); statistical analysis was carried out through partial least squares regression and random cross-validation procedure. Retention times in RP-HPLC method were stable (RSD between 0.03 and 0.80%), whereas the RSD of peak area (from 0.25 to 8.48%) was affected by WP relative abundance. Higher coefficients of determination in validation for MIRS model were obtained for protein fractions present in whey in large amounts, such as β-LG (0.58), total identified WP (0.58), and α-LA (0.56). Results of this study suggest that MIRS is an easy method for rapid quantification of detail protein in sweet whey, even if better resolution was achieved with the method based on RP-HPLC. The prediction of WP in sweet whey by MIRS might be used for screening and for classifying sweet whey according to its total and individual WP contents. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed

  4. Isolation and HPLC method development of azafrin from Alectra parasitica var. chitrakutensis.

    Science.gov (United States)

    Agrawal, Poonam; Laddha, Kirti; Tiwari, Ashok

    2014-01-01

    This study was undertaken to isolate and quantify azafrin in Alectra parasitica (Scrophulariaceae) rhizomes. A simple method for the isolation of carotenoid, azafrin, involves solvent extraction of the dried rhizome powder using a single solvent and further purification by recrystallisation. The structure of the compound was elucidated and confirmed by thin-layer chromatography, infrared spectroscopy, mass spectroscopy and nuclear magnetic resonance spectral analysis. A specific and rapid reversed-phase high-performance liquid chromatography (HPLC) method was developed for the analysis of azafrin. The method was validated for accuracy, precision, linearity and specificity. Validation revealed that the method is specific, accurate, precise, reliable and reproducible. The proposed HPLC method can be used for the identification and quantitative analysis of azafrin in A. parasitica rhizomes.

  5. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms

    OpenAIRE

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm ? 4mm ? 5 ?m) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS wa...

  6. Development and validation of reversed-phase high performance liquid chromatographic method for analysis of cephradine in human plasma samples

    International Nuclear Information System (INIS)

    Ahmad, M.; Usman, M.; Madni, A.; Akhtar, N.; Khalid, N.; Asghar, W.

    2010-01-01

    An HPLC method with high precision, accuracy and selectivity was developed and validated for the assessment of cephradine in human plasma samples. The extraction procedure was simple and accurate with single step followed by direct injection of sample into HPLC system. The extracted cephradine in spiked human plasma was separated and quantitated using reversed phase C/sub 18/ column and UV detection wavelength of 254 nm. The optimized mobile phase of new composition of 0.05 M potassium dihydrogen phosphate (pH 3.4)-acetonitrile (88: 12) was pumped at an optimum flow rate of 1 mL.min/sup 1/. The method resulted linearity in the concentration range 0.15- 20 micro g mL/sup -1/. The limit of detection (LOD) and limit of quantification (LOQ) were 0.05 and 0.150 Microg.mL/sup -1/, respectively. The accuracy of method was 98.68 %. This method can 1>e applied for bioequivalence studies and therapeutic drug monitoring as well as for the routine analysis of cephradine. (author)

  7. Determination of organic and inorganic mercury species in Sungai Kinta, Perak by reversed-phase high performance liquid chromatography (HPLC) on-line coupled with ICP-MS

    International Nuclear Information System (INIS)

    Norshidah Baharuddin; Norashikin Saim; Rozita Osman; Sharifuddin Mohd Zain

    2012-01-01

    This paper describes a simple method for mercury speciation in river water samples of Sungai Kinta, Perak. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ ICP-MS). Separation of mercury species was accomplished within 6 minutes on an AQ C18 4.6 mm i.d x 150 mm, 5 μm reversed phase column with 0.1 % (w/ v) L-cysteine as mobile phase. Under the optimum instrumental conditions, recoveries of 101-104 % for MeHg + and 96 - 104 % for Hg 2+ were obtained with experimental detection limits of 1ngL -1 for inorganic mercury and 1.5 μgL -1 for organic mercury. (author)

  8. [Determination of glycyrrhizinic acid in biotransformation system by reversed-phase high performance liquid chromatography].

    Science.gov (United States)

    Li, Hui; Lu, Dingqiang; Liu, Weimin

    2004-05-01

    A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.

  9. NONLINEAR-REGRESSION METHODS FOR MODELING OF HETEROSCEDASTIC RETENTION DATA IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    HENDRIKS, MMWB; COENEGRACHT, PMJ; DOORNBOS, DA

    1994-01-01

    New models have been developed that accurately describe the response surfaces of capacity factors that are a function of changes in the pH and the fraction of organic modifier in reversed-phase high-performance liquid chromatography (RP-HPLC). The purpose of this article is to illustrate one of the

  10. A rapid and validated HPLC method to quantify sphingosine 1-phosphate in human plasma using solid-phase extraction followed by derivatization with fluorescence detection

    NARCIS (Netherlands)

    Butter, Jan J.; Koopmans, Richard P.; Michel, Martin C.

    2005-01-01

    We describe the development and validation of analytical methodology for the determination of sphingosine 1-phosphate (S1P) in plasma. It uses solid-phase extraction (SPE) followed by an automated reversed-phase gradient HPLC column-switching system with a pre-column derivatization with

  11. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.

    Science.gov (United States)

    Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep

    2015-01-01

    A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation

  12. Rapid purification of radioiodinated peptides with Sep-Pak reversed phase cartridges and HPLC

    International Nuclear Information System (INIS)

    Miller, J.J.; Schultz, G.S.; Levy, R.S.

    1984-01-01

    A simple, rapid method is described for the purification of radioiodinated peptides for use in radioimmuno- and in radioreceptor assays. Iodinated reaction mixtures are applied directly onto Sep-Pak disposable, reversed phase cartridges equilibrated with phosphate buffer. Unreacted 125-iodide and other non-peptide reaction components are eluted with buffer. The peptide fraction is then eluted with 70% buffer:30% acetonitrile. The peptide fraction is further purified by reversed phase high pressure liquid chromatography to separate the native peptide and the mono- and diiodo-derivatives. In this study the method is used to prepare 125-iodide-labeled monoiodo-leucine enkephalin and monoiodo-angiotensin II, which are free of the parent peptides and diiodo-derivatives and are of maximum obtainable specific radioactivity. The usefulness of these labeled peptides in radioimmuno- and radioreceptor assays is demonstrated by their binding to specific antibodies and receptors, respectively. (author)

  13. Offline solid-phase extraction for preconcentration of pharmaceuticals and personal care products in environmental water and their simultaneous determination using the reversed phase high-performance liquid chromatography method.

    Science.gov (United States)

    G Archana; Dhodapkar, Rita; Kumar, Anupama

    2016-09-01

    The present study reports a precise and simple offline solid-phase extraction (SPE) coupled with reversed-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous determination of five representative and commonly present pharmaceuticals and personal care products (PPCPs), a new class of emerging pollutants in the aquatic environment. The target list of analytes including ciprofloxacin, acetaminophen, caffeine benzophenone and irgasan were separated by a simple HPLC method. The column used was a reversed-phase C18 column, and the mobile phase was 1 % acetic acid and methanol (20:80 v/v) under isocratic conditions, at a flow rate of 1 mL min(-1). The analytes were separated and detected within 15 min using the photodiode array detector (PDA). The linearity of the calibration curves were obtained with correlation coefficients 0.98-0.99.The limit of detection (LOD), limit of quantification (LOQ), precision, accuracy and ruggedness demonstrated the reproducibility, specificity and sensitivity of the developed method. Prior to the analysis, the SPE was performed using a C18 cartridge to preconcentrate the targeted analytes from the environmental water samples. The developed method was applied to evaluate and fingerprint PPCPs in sewage collected from a residential engineering college campus, polluted water bodies such as Nag river and Pili river and the influent and effluent samples from a sewage treatment plant (STP) situated at Nagpur city, in the peak summer season. This method is useful for estimation of pollutants present in microquantities in the surface water bodies and treated sewage as compared to nanolevel pollutants detected by mass spectrometry (MS) detectors.

  14. Qualitative analysis of MDR-reversing Anastasia Black (Russian black sweet pepper, Capsicum annuum, Solanaceae) extracts and fractions by HPLC and LC-MS-MS methods.

    Science.gov (United States)

    Schelz, Zsuzsanna; Molnár, Joseph; Fogliano, Vincenzo; Ferracane, Rosalia; Pernice, Rita; Shirataki, Yoshiaki; Motohashi, Noboru

    2006-01-01

    In earlier experiments, the MDR (multidrug resistance)-reversal activities of Anastasia Black (Russian black sweet pepper) extracts had been analysed. Recently, the most effective MDR reversing extracts and fractions have been separated by HPLC (high-performance liquid chromatography, for carotenoids) and LC-MS-MS (HPLC combined with mass spectrometry, for phenolic compounds) methods. As a result of the analytical studies, the following flavonoids had been identified: feruloyl glucopyranoside, quercetin rhamnopyranoside glucopyranoside, luteolin glucopyranoside arabinopyranoside, apigenin glucopyranoside arabinopyranoside, quercetin rhamnopyranoside, luteolin arabinopyranoside diglucopy-ranoside, hesperidine and luteolin glucuronide. According to the literature, the aglycones of these phenolic compounds exhibit MDR-reversal activity in vitro, and the connection between the phenolic content of Anastasia Black and MDR-reversal action was therefore studied by different analytical methods. The results of this study revealed that the identified flavonoids of Anastasia Black may be only partially responsible for the modulation of the MDR of mouse lymphoma cells. Other lipophilic compounds, most probably carotenoids, present in Russian black sweet pepper may act as inhibitors of MDR reversal.

  15. Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC

    Science.gov (United States)

    Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.

    2018-04-01

    Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.

  16. Rapid Quantitative Analysis of Naringenin in the Fruit Bodies of Inonotus vaninii by Two-phase Acid Hydrolysis Followed by Reversed Phase-high Performance Liquid Chromatography-ultra Violet.

    Science.gov (United States)

    Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping

    2017-01-01

    Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii

  17. Determination of Dyclonine Hydrochloride by a HPLC Method and Camphor and Menthol by a GC Method in Compound Lotion

    Directory of Open Access Journals (Sweden)

    Suying Ma

    2013-01-01

    Full Text Available A high performance liquid chromatographic (HPLC method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC method with flame ionization detector (FID for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18 reversed-phase column (5 μm, 4.6 mm × 200 mm and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm. The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.

  18. ANALYSIS OF BASIC PSYCHOTROPIC DRUGS IN BIOLOGICAL FLUIDS AND TISSUES BY REVERSED-PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.

    Science.gov (United States)

    Petruczynik, Anna; Waksmundzka-Hajnos, Monika

    2017-03-01

    The review of the RP HPLC analysis of basic psychotropic drugs is presented. It contains sample preparation methods with centrifugation, protein precipitation, liquid-liquid extraction (LLE), dispersive liquid-liquid microextraction (DLLME), solid-phase extraction (SPE), solid-phase microextraction (SPME), microwave-assisted extraction (MAE) and RP-HPLC analysis. Chromatographic behavior of basic drugs in aqueous media - eluents used in reversed phase systems is discussed. Methods of blocking of residue surface silanols' interaction are mentioned. Analytical methods used for the analysis are divided into parts according with the above methods: the use of low-pH eluents, the use of high-pH eluents, the use of silanol blockers, special stationary phases for basic analytes. Literature connected with the sample preparation methods and analytical systems for the drug analysis are cited in details and presented also in Table 1.

  19. Separation and determination of minor photosynthetic pigments by reversed-phase HPLC with minimal alteration of chlorophylls.

    Science.gov (United States)

    Nakamura, A; Watanabe, T

    2001-04-01

    Reversed-phase HPLC conditions for separation of chlorophyll (Chl) a, Chl a' (the C132-epimer of Chl a), pheophytin (Pheo) a (the primary electron acceptor of photosystem (PS) II), and phylloquinone (PhQ) (the secondary electron acceptor of PS 1), have been developed. Pigment extraction conditions were optimized in terms of pigment alteration and extraction efficiency. Pigment composition analysis of light-harvesting complex II, which would not contain Chl a' nor Pheo a, showed the Chl a'/Chl a ratio of 3-4 x 10(-4) and the Pheo a/Chl a ratio of 4-5 x 10(-4), showing that the conditions developed here were sufficiently inert for Chl analysis. Preliminary analysis of thylakoid membranes with this analytical system gave the PhQ/Chl a' ratio of 0.58 +/- 0.03 (n = 4), in line with the stoichiometry of one molecule of Chl a' per PS I.

  20. DETERMINATION AND VALIDATION OF MEBHYDROLINE NAPADISYLATE IN TABLETS BY HPLC

    Directory of Open Access Journals (Sweden)

    Lestyo Wulandari

    2010-06-01

    Full Text Available An accurate and sensitive HPLC method has been developed for the determination of mebhydroline napadisylate in the tablet. The Chromatography was performed on a reversed phase C-18 column, using a mobile phase of acetonitrile : ammonia 25% (80 : 20 v/v at ambient temperature 25±5 °C and UV detection operates at 320 nm in an overall analysis time of about 15 min, based on peak area. This HPLC method is selective, precise, and accurate and can be used for routine analysis of pharmaceutical preparation in industrial quality-control laboratories.   Keywords : HPLC, mebhydroline napadisylate, validation

  1. Reversed-phase thin-layer chromatography of homologs of Antimycin-A and related derivatives

    Science.gov (United States)

    Abidi, Sharon L.

    1989-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  2. Development and Validation of a Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Indole-3-Acetic Acid, Indole-3-Pyruvic Acid, and Abscisic Acid in Barley (Hordeum vulgare L.).

    Science.gov (United States)

    Nakurte, Ilva; Keisa, Anete; Rostoks, Nils

    2012-01-01

    A simple, sensitive, precise, and specific reverse HPLC method was developed and validated for the determination of plant hormones in barley (Hordeum vulgare L.). The method includes extraction in aqueous organic solvent followed by solid-phase extraction, sample evaporation, and reversed-phase HPLC analysis in a general purpose UV-visible (abscisic acid (ABA)) and fluorescence detection (indole-3-acetic acid (IAA) and indole-3-pyruvic acid (IPA)), high-performance liquid chromatography system. The separation was carried out on Zorbax Eclipse XDB C8 column (150  ×  4.6  mm I.D) with a mobile phase composed of methanol and 1% acetic acid (60 : 40 v/v) in isocratic mode at a flow rate of 1 ml min(-1). The detection was monitored at 270 nm (ABA) and at 282 nm (Ex) and 360 nm (Em) (IAA, IPA). The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification, and robustness. The determined validation parameters are in the commonly acceptable ranges for that kind of analysis.

  3. Gas release-based prescreening combined with reversed-phase HPLC quantitation for efficient selection of high-γ-aminobutyric acid (GABA)-producing lactic acid bacteria.

    Science.gov (United States)

    Wu, Qinglong; Shah, Nagendra P

    2015-02-01

    High γ-aminobutyric acid (GABA)-producing lactobacilli are promising for the manufacture of GABA-rich foods and to synthesize GRAS (generally recognized as safe)-grade GABA. However, common chromatography-based screening is time-consuming and inefficient. In the present study, Korean kimchi was used as a model of lactic acid-based fermented foods, and a gas release-based prescreening of potential GABA producers was developed. The ability to produce GABA by potential GABA producers in de Man, Rogosa, and Sharpe medium supplemented with or without monosodium glutamate was further determined by HPLC. Based on the results, 9 isolates were regarded as high GABA producers, and were further genetically identified as Lactobacillus brevis based on the sequences of 16S rRNA gene. Gas release-based prescreening combined with reversed-phase HPLC confirmation was an efficient and cost-effective method to identify high-GABA-producing LAB, which could be good candidates for probiotics. The GABA that is naturally produced by these high-GABA-producing LAB could be used as a food additive. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Determination and Quantification of the Vinblastine Content in Purple, Red, and White Catharanthus Roseus Leaves Using RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    Rohanizah Abdul Rahim

    2018-03-01

    Full Text Available Purpose: To determine and quantify vinblastine in different varieties of Catharanthus roseus using reversed-phase HPLC method. Methods: The liquid chromatographic separation was performed using a reversed phase C18, Microsorb - MV column (250 mm x 4.6 mm, 5 µm at room temperature and eluted with a mobile phase containing methanol – phosphate buffer (5 mM, pH 6.0 – acetonitrile with different proportion gradient elution at a flow rate of 2.0 mL min-1 and detection at 254 nm. Results: The HPLC method was utilized for the quantification of vinblastine in purple, red and white varieties of Catharanthus roseus leaves. The separation was achieved in less than 8 min. The peak confirmation was done based on the retention times and UV spectra of the reference substance. The method was validated with respect to linearity, precision, recovery, limit of detection and quantification. Results showed that the purple variety gives 1.2 and 1.5 times more vinblastine concentration compared to the white and pink varieties, respectively. Conclusion: The obtained results from different varieties are thus useful for the purpose of vinblastine production from Catharanthus roseus plant.

  5. A simple reversed phase high-performance liquid chromatography (RP-HPLC method for determination of curcumin in aqueous humor of rabbit

    Directory of Open Access Journals (Sweden)

    Akhilesh Mishra

    2014-01-01

    Full Text Available This article describes a simple and rapid method for determination of curcumin (diferuloylmethane in aqueous humor of rabbit using high-performance liquid chromatography (HPLC. Analysis was performed using a C-18 column (250 × 4.6 mm, 5 μ luna by isocratic elution with a mobile phase containing 25 mM potassium dihydrogen orthophosphate (pH 3.5: Acetonitrile (40:60 and detection at 424 nm using a photodiode array (PDA detector for curcumin. The regression data for curcumin showed a good linear relationship with r 2 > 0.998 over the concentration range of 0.1-10 μg ml−1 . Relative standard deviations (RSD for the intraday and interday coefficient of variations for the assay were less than 5.0 and 8.5, respectively. The recovery of the method was between 79.8-83.6%. The quantification limit of the method for curcumin was 0.01 μg ml−1 . This method has good accuracy, precision, and quantitation limit. It is also concluded that the method is useful for measuring very low curcumin concentrations in aqueous humor.

  6. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    Science.gov (United States)

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  7. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    OpenAIRE

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and...

  8. Development and validation of a RP- HPLC method for the quantitation studies of bromadiolone in Ratitox F

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean

    2011-12-01

    Full Text Available An isocratic high-performance liquid chromatography (HPLC procedure was developed for the quantitative determination of bromadiolone (hydroxycoumarins in Ratitox F product – rodenticide. HPLC separation was carried out by reversed phase chromatography ODS 2 Hypersil C18 (250 mm x 4.6 mm i.e.; 5 ìm particle size, held in thermostat at 25°C. The mobile phase consisted of methanol/0.1% aqueous solution phosphoric acid (90/10v/v, with a flow rate of 1 ml/min and with UV detection at 265 nm. In order to validate the method, the following parameters have been investigated- linearity (r2 = 0.9999, range, precision, accuracy, specificity, limit of detection and limit of quantification. The described method can be successfully applied for the analysis of Ratitox F – rodenticide.

  9. Rapid separation of lanthanides and actinides on small particle based reverse phase supports

    Energy Technology Data Exchange (ETDEWEB)

    Datta, A.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R. [Chemistry Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2010-07-01

    This paper presents the results on the use of short columns (3-5 cm long) with small particle size (1.8 {mu}m) for high performance liquid chromatographic separation of individual lanthanides and uranium from plutonium as well as uranium from thorium to achieve rapid separations i.e. separation time as short as 3.6 min for individual lanthanides, 1 min for thorium-uranium and 4.2 min for uranium from plutonium. These advantages can be exploited to significantly reduce analysis time, liquid waste generation as well as dose to operator when radioactive samples are analysed e.g. burn-up determination. In the present work, a dynamic ion-exchange chromatographic separation technique was employed using camphor-10-sulfonic acid (CSA) as the ion-pairing reagent and {alpha}-hydroxy isobutyric acid ({alpha}-HIBA) as the complexing reagent for the isolation of individual lanthanides as well as the separation of uranium from thorium. Uranium was separated from Pu(III) as well as Pu(IV) by reverse phase HPLC technique. The reverse phase HPLC was also investigated for the isolation and quantitative determination of uranium from thorium as well as lanthanide group from uranium. The dynamic ion-exchange technique using small particle support was demonstrated for measuring the concentrations of lanthanide fission products such as La, Ce, Pr, Nd and Sm in the dissolver solution of fast reactor fuel. Similarly, the assay of uranium in the dissolver solution of fast reactor was carried out using reverse phase HPLC technique. The rapid separation technique using reverse phase HPLC was also demonstrated for separation of lanthanides as a group from uranium matrix; samples of LiCl-KCl eutectic salt containing chlorides of lanthanides in uranium matrix (typically 1: 2000) were analysed. (orig.)

  10. Determination of 5-fluorouracil in plasma with HPLC-tandem mass spectrometry

    NARCIS (Netherlands)

    van Kuilenburg, A. B. P.; van Lenthe, H.; Maring, J. G.; van Gennip, A. H.

    2006-01-01

    In this article, we describe a fast and specific method to measure 5FU with HPLC tandem-mass spectrometry. Reversed-phase HPLC was combined with electrospray ionization tandem mass spectrometry and detection was performed by multiple-reaction monitoring. Stable-isotope-labeled 5FU (1,3-15N2-5FU) was

  11. Optimized Analytical Method to Determine Gallic and Picric Acids in Pyrotechnic Samples by Using HPLC/UV (Reverse Phase)

    International Nuclear Information System (INIS)

    Garcia Alonso, S.; Perez Pastor, R. M.

    2013-01-01

    A study on the optimization and development of a chromatographic method for the determination of gallic and picric acids in pyrotechnic samples is presented. In order to achieve this, both analytical conditions by HPLC with diode detection and extraction step of a selected sample were studied. (Author)

  12. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Validation of a dissolution method with RP-HPLC analysis for Perindopril erbumine and Indapamide combination tablet

    Directory of Open Access Journals (Sweden)

    Jain P.S.

    2012-01-01

    Full Text Available A Dissolution method with high performance liquid chromatography (HPLC analysis was validated for perindopril erbumine and indapamide in combination tablet formulation. The method was validated to meet requirements for a global regulatory filing and this validation included specificity, linearity, accuracy, precision, range, robustness and solution stability studies. The dissolution method, which uses USP apparatus 1 with basket rotating at 100 rpm, 1000 ml of phosphate buffer pH 6.8 as the dissolution medium, and reversed-phased HPLC was carried out at 50⁰C on a 4.6mm×250mm 5μm cyano column that contained USP packing L1 with acetonitrile: buffer pH 2.8::40:60 (v/v, as mobile phase. UV detector was set at 225 nm. A method was found to be selective, linear, accurate and precise in the specified ranges. Intra-day and inter-day variability for method was <2% RSD. This method was successfully used for quantification of perindopril erbumine and indapamide combination tablet formulations.

  14. A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

    Science.gov (United States)

    Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan

    2017-01-01

    Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806

  15. Analysis of Theobromine and Related Compounds by Reversed Phase High-Performance Liquid Chromatography with Ultraviolet Detection: An Update (1992–2011

    Directory of Open Access Journals (Sweden)

    Sandra Aparecida de Assis

    2011-01-01

    Full Text Available Theobromine and its related compounds, such as caffeine and theophylline, are secondary metabolites that belong to the alkaloids and have economic and cultural importance. These alkaloids have demonstrated stimulatory effects on the central nervous, gastrointestinal, cardiovascular, renal and respiratory systems, resulting in 'energy arousal', increased motivation to work, increased alertness and increased cognitive function. Several analytical methods have been used to analyse these compounds, but reversed phase high-performance liquid chromatography (RP-HPLC is the most commonly applied because of its efficiency, sensitivity, specificity and speed. This review describes the analyses of theobromine-related compounds by RP-HPLC with ultraviolet detection (UV in four sources: food, beverages, biological fluids and plants. Many RP-HPLC methods have been developed and optimized for the detection and quantification of these natural compounds. Elution under isocratic conditions is the most frequent method, with a water, methanol and acetonitrile mixture modified with acetic, phosphoric or formic acid as the mobile phase. For xanthine analysis, the use of reversed phase high-performance liquid chromatography with an ultraviolet/diode array detector (UV/DAD is particularly suitable as derivation is not required; it allows the analysis of absorbance at all wavelengths, it is simple and rapid.

  16. Rapid determination of human globin chains using reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wan, Jun-Hui; Tian, Pei-Ling; Luo, Wei-Hao; Wu, Bing-Yi; Xiong, Fu; Zhou, Wan-Jun; Wei, Xiang-Cai; Xu, Xiang-Min

    2012-07-15

    Reversed-phase high-performance liquid chromatography (RP-HPLC) of human globin chains is an important tool for detecting thalassemias and hemoglobin variants. The challenges of this method that limit its clinical application are a long analytical time and complex sample preparation. The aim of this study was to establish a simple, rapid and high-resolution RP-HPLC method for the separation of globin chains in human blood. Red blood cells from newborns and adults were diluted in deionized water and injected directly onto a micro-jupiter C18 reversed-phase column (250 mm × 4.6 mm) with UV detection at 280 nm. Under the conditions of varying pH or the HPLC gradient, the globin chains (pre-β, β, δ, α, (G)γ and (A)γ) were denatured and separated from the heme groups in 12 min with a retention time coefficient of variation (CV) ranging from 0.11 to 1.29% and a peak area CV between 0.32% and 4.86%. Significant differences (P<0.05) among three groups (normal, Hb H and β thalassemia) were found in the area ratio of α/pre-β+β applying the rapid elution procedure, while P≥0.05 was obtained between the normal and α thalassemia silent/trait group. Based on the ANOVA results, receiver operating characteristic (ROC) curve analysis of the δ/β and α/pre-β+β area ratios showed a sensitivity of 100.0%, and a specificity of 100.0% for indicating β thalassemia carriers, and a sensitivity of 96.6% and a specificity of 89.6% for the prediction of hemoglobin H (Hb H) disease. The proposed cut-off was 0.026 of δ/β for β thalassemia carriers and 0.626 of α/pre-β+β for Hb H disease. In addition, abnormal hemoglobin hemoglobin E (Hb E) and Hb Westmead (Hb WS) were successfully identified using this RP-HPLC method. Our experience in developing this RP-HPLC method for the rapid separation of human globin chains could be of use for similar work. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Development and validation of RP-HPLC method for analysis of multicomponent cough-cold syrup formulation

    OpenAIRE

    Ivković, Branka; Marković, Bojan; Vladimirov, Sote

    2014-01-01

    In this study a reversed phase HPLC method for rapid and simultaneous identification and quantification of doxylamine succinate, ephedrine sulfate, dextrometorphane hydrobromide, paracetamole and sodium benzoate in cough-cold syrup formulation was described. Separation was carried out on XTerraTM RP 18, Waters (150 mm x 4.6 mm column, 5 μm particle size). For the analysis of investigated substances gradient elution was used employing water, pH adjusted at 2.5 with 85 % ortophosphoric acid as ...

  18. Phase retrieval with the reverse projection method in the presence of object's scattering

    International Nuclear Information System (INIS)

    Wang, Zhili; Gao, Kun; Wang, Dajiang

    2017-01-01

    X-ray grating interferometry can provide substantially increased contrast over traditional attenuation-based techniques in biomedical applications, and therefore novel and complementary information. Recently, special attention has been paid to quantitative phase retrieval in X-ray grating interferometry, which is mandatory to perform phase tomography, to achieve material identification, etc. An innovative approach, dubbed “Reverse Projection” (RP), has been developed for quantitative phase retrieval. The RP method abandons grating scanning completely, and is thus advantageous in terms of higher efficiency and reduced radiation damage. Therefore, it is expected that this novel method would find its potential in preclinical and clinical implementations. Strictly speaking, the reverse projection method is applicable for objects exhibiting only absorption and refraction. In this contribution, we discuss the phase retrieval with the reverse projection method for general objects with absorption, refraction and scattering simultaneously. Especially, we investigate the influence of the object's scattering on the retrieved refraction signal. Both theoretical analysis and numerical experiments are performed. The results show that the retrieved refraction signal is the product of object's refraction and scattering signals for small values. In the case of a strong scattering, the reverse projection method cannot provide reliable phase retrieval. Those presented results will guide the use of the reverse projection method for future practical applications, and help to explain some possible artifacts in the retrieved images and/or reconstructed slices. - Highlights: • Accurate phase retrieval by the reverse projection method without object's scattering. • Retrieved refraction signal contaminated by the object's scattering. • Refraction signal underestimated by the reverse projection method. • Guide the use of the reverse projection method for

  19. Development and validation of an HPLC method for simultaneous determination of trimethoprim and sulfamethoxazole in human plasma.

    Science.gov (United States)

    Sayar, Esin; Sahin, Selma; Cevheroglu, Semsettin; Hincal, A Atilla

    2010-09-01

    The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used in the treatment of many common infections such as urinary, respiratory and gastrointestinal tract infections. The aim of this study was to determine TMP and SMX simultaneously in human plasma samples by high performance liquid chromatography (HPLC) using antipyrine as the internal standard. Separation of the compounds was achieved on a reverse-phase C8 column packed with 5 microm dimethyl octadecylsilyl bonded amorphous silica (4.6 mm x 250 mm) column using a mobile phase consisted of potassium hydrogen phosphate, acetonitrile, methanol and water adjusted to pH 6.2. The mobile phase was delivered at a flow rate of 1 mL min- and the effluent was monitored using Max plot technique at 25 derees C. Retention times were 5 min for TMP, 7 min for antipyrine and 9 min for SMX. Quantitation limits were 10 ng mL(-1) for TMP and 50 ng mL(-1) for SMX. Our findings indicated that the developed HPLC method was precise, accurate, specific and sensitive for simultaneous determination of TMP and SMX. Proposed HPLC method was successfully applied for the analysis of TMP and SMX in human plasma after oral administration of a co-trimoxazole tablet to human volunteers.

  20. HPLC WITH SOLID PHASE EXTRACTION FOR IDENTIFICATION AND DIAGNOSIS OF ORGANOPHOSPHOROUS POISONING IN GOATS

    Directory of Open Access Journals (Sweden)

    S. Manna

    2014-12-01

    Full Text Available High performance liquid chromatographic determination of organophosphorous compound has been done by reverse phase chromatography in goats. The goats were dying showing the symptoms of organophosphorous poisoning. The viscera and stomach contents sample were received from Project Co-Ordinator, Animal Disease Research Institute, Phulnakhara, Cuttack, Orissa. The analysis of samples by HPLC with UV detector after cleaning up in Solid Phase Extraction (SPE revealed presence of malathion that was later quantified.

  1. An improved HPLC method for determination of colocynthin in colocynth

    Directory of Open Access Journals (Sweden)

    M. Shekarchi

    2015-10-01

    Full Text Available Background and objectives: Colocynthin is the major active secondary metabolite of colocynth, Citrullus colocynthis (L. Schrad, which has been used in traditional and ethno medicine of many countries.  It could be considered as an active marker for quality control of colocynth and its herbal products. Analysis and standardization of colocynth and its herbal preparations are a critical issue for their safe applications in phytotherapy and traditional medicine. In the present work, a simple and efficient sample preparation was developed and optimized through combination of matrix solid phase dispersion and ultrasonic assisted extraction. In addition, analytical reversed-phase HPLC method was optimized for analyzing the concentration of colocynthin in colocynth pulp. Methods: Powdered colocynth pulp was grinded with diatomaceous earth to obtain a homogenous mixture. The blend was mixed with methanol and extracted by sonication, followed by centrifugation and filtration. The analytical chromatographic separation was carried out using Luna C18 in isocratic elution with methanol: isopropanol: water: triflouroacetic acid (30:10:60:0.1 v/v. The method was validated as well.  Results: The validation parameters were determines as follows, linear range (r2 = 0.999, 75-500 μg/mL, precision (intra-day < 2.7%, inter-day = 4.4% and accuracy measured via determination of recovery (90-107%. The limit of detection and quantization were calculated 8.5 and 25.7 μg/mL, respectively. Conclusion: Regarding the relatively high content of colocynthin in colocynth pulp, the validated HPLC method could be applied for quality control of colocynth pulp used in Traditional Persian Medicine.

  2. Separation, purification and identification of flavonoid glycosides using reversed phase hplc

    International Nuclear Information System (INIS)

    Hasan, A.; Khan, M.A.

    2002-01-01

    Optimal high performance liquid chromatography (HPLC) separation conditions and semi-preparative scale isolation of flavonoid glycosides from three plant species namely Vitex nagunda, Rubus ulmifolious and Malotus philipensis is reported. Identification of purified flavonoid glycoside was achieved using spiking technique in HPLC. (author)

  3. A simple micro-batch ion-exchange resin extraction method coupled with reverse-phase HPLC (MBRE-HPLC) to quantify lactoferrin in raw and heat-treated bovine milk.

    Science.gov (United States)

    Pochet, Sylvie; Arnould, Céline; Debournoux, Perrine; Flament, Jocelyne; Rolet-Répécaud, Odile; Beuvier, Eric

    2018-09-01

    Lactoferrin is an iron-binding cationic glycoprotein (pI = 8.7) beneficial for mammal health, especially udder and milk preservation. A new simple two-step method of quantification was developed. Lactoferrin in 1 mL of bovine skim milk was first adsorbed onto 100 mg of macroporous sulfonated-resin at pH 6.8 by rotary stirring for 90 min at 20-25 °C. After washing the resin, lactoferrin was desorbed using 1 mL of 2 M NaCl containing phenylalanine as a dilution marker, then fully resolved and quantified by RP-HPLC at 220 nm using a wide-bore C4 silica column. This robust, inexpensive and flexible method improves selectivity (no protein interference) and sensitivity compared to previous HPLC methods. In-laboratory validation demonstrated its linearity (25 to 514 µg Lf mL -1 ), accuracy (110 to 98% recovery), and precision (<4%), which were comparable to immuno-based methods. The results for individual raw cow's milk were strongly correlated with results using an ELISA test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Stability-Indicating RP-HPLC Method for Assay of Silver Lactate

    Directory of Open Access Journals (Sweden)

    V. Srinivasan

    2011-01-01

    Full Text Available A simple, economic and time-efficient stability-indicating, reverse-phase high-performance liquid chromatographic (RP-HPLC method has been developed for analysis of silver lactate in the presence of degradation products generated by decomposition. When silver lactate was subjected to acid hydrolysis, base hydrolysis, oxidative, photolytic, humidity and thermal stress, degradation was observed during base hydrolysis, oxidation, humidity and thermal stress. The drug was found to be stable to other stress conditions. Successful chromatographic condition of the drug from the degradation products formed under stress conditions was achieved on a phenomenex Gemini column with potassium dihydrogen phosphate buffer, pH adjusted to 2.2 with orthophosphoric acid, as mobile phase. The method was validated for linearity, precision, specificity and robustness and can be used for quality-control during manufacture and assessment of the stability of samples of silver lactate. To the best of our knowledge, a validated stability-indicating LC assay method for silver lactate based on lactic acid is reported for the first time.

  5. Comparison of Separation of Seed Oil Triglycerides Containing Isomeric Conjugated Octadecatrienoic Acid Moieties by Reversed-Phase HPLC

    Directory of Open Access Journals (Sweden)

    Anh Van Nguyen

    2017-12-01

    Full Text Available Relative retention analysis and increment approach were applied for the comparison of triglycerides (TGs retention of a broad set of plant seed oils with isomeric conjugated octadecatrienoic acids (CLnA by reversed-phase HPLC for “propanol-2-acetonitrile” mobile phases and Kromasil 100-5C18 stationary phase with diode array detection (DAD and mass spectrometric (MS detection. The subjects of investigation were TGs of seed oils: Calendula officinalis, Catalpa ovata, Jacaranda mimosifolia, Centranthus ruber, Momordica charantia, Trichosanthes anguina, Punica granatum, Thladiantha dubia, Valeriana officinalis, and Vernicia montana. It was found that a sequence of elution of TGs of the same types is the same without any inversions for full range of mobile phase compositions: punicic (C18:39Z11E13Z < jacaric (C18:38Z10E12Z < catalpic (C18:39E11E13Z < α-eleostearic (C18:39Z11E13E < calendic (C18:38E10E12Z < β-eleostearic (C18:39E11E13E < all-E calendic (C18:38E10E12E acids. TGs and fatty acid compositions were calculated for all oil samples. Regularities of solute retentions as a function of isomeric conjugated octadecatrienoic acid moiety structure are discussed. Thus, it was proven that it is possible to differentiate TGs of complex composition with moieties of all natural CLnA by retention control accomplished by electronic spectra comparison, even though there are only three types of electronic-vibration spectra for seven isomeric CLnA.

  6. Stability-Indicating RP-HPLC Methods for the Determination of Fluorometholone in Its Mixtures with Sodium Cromoglycate and Tetrahydrozoline Hydrochloride.

    Science.gov (United States)

    El-Bagary, Ramzia I; Fouad, Marwa A; El-Shal, Manal A; Tolba, Enas H

    2016-07-01

    Two stability-indicating reversed-phase liquid chromatographic methods were developed and validated for the determination of fluorometholone (FLU) in its mixtures with sodium cromoglycate (SCG) and tetrahydrozoline hydrochloride (THZ). The first HPLC method (Method 1) was based on isocratic elution of FLU and SCG along with their alkaline degradation products on a reversed phase C18 column (250 × 4.6 mm id)-ACE Generix 5, using a mobile phase consisting of methanol-water (70 : 30, v/v), pH adjusted to 2.5 using orthophosphoric acid at a flow rate of 1.2 mL min(-1) Quantitation was achieved with UV detection at 240 nm. The second HPLC method (Method 2) was based on isocratic elution of FLU, its alkaline degradation product and THZ on a reversed phase C8 column (250 × 4.6 mm)-ACE Generix 5, using a mobile phase consisting of acetonitrile-50 mM potassium dihydrogen orthophosphate (40 : 60, v/v) at a flow rate of 2 mL min(-1) Quantitation was achieved by applying dual-wavelength detection, where FLU and its alkaline degradation product were detected at 240 nm and THZ was detected at 215 nm at ambient temperatures. Linearity, accuracy and precision were found to be acceptable over the concentration range of 5-50 and 10-500 μg mL(-1) for FLU and SCG (Method 1) and over the concentration range of 5-80 and 5-60 μg mL(-1) for FLU and THZ (Method 2), respectively. Besides, the FLU alkaline degradation product was verified using IR, NMR and LC-MS spectroscopy. The two proposed methods could be successfully applied for the routine analysis of the studied drugs either in their pure bulk powders or in their pharmaceutical preparations without any preliminary separation step. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Development and validation of a stability-indicating RP–HPLC method for estimation of atazanavir sulfate in bulk

    Directory of Open Access Journals (Sweden)

    S. Dey

    2017-04-01

    Full Text Available A stability-indicating reverse phase–high performance liquid chromatography (RP–HPLC method was developed and validated for the determination of atazanavir sulfate in tablet dosage forms using C18 column Phenomenix (250 mm×4.6 mm, 5 μm with a mobile phase consisting of 900 mL of HPLC grade methanol and 100 mL of water of HPLC grade. The pH was adjusted to 3.55 with acetic acid. The mobile phase was sonicated for 10 min and filtered through a 0.45 μm membrane filter at a flow rate of 0.5 mL/min. The detection was carried out at 249 nm and retention time of atazanavir sulfate was found to be 8.323 min. Linearity was observed from 10 to 90 μg/mL (coefficient of determination R2 was 0.999 with equation, y=23.427x+37.732. Atazanavir sulfate was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation, and the results showed that it was more sensitive towards acidic degradation. The method was validated as per ICH guidelines.

  8. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  9. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies.

    Science.gov (United States)

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-06-01

    The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.

  10. Solid-phase extraction and HPLC assay of nicotine and cotinine in plasma and brain.

    Science.gov (United States)

    Dawson, Ralph; Messina, S M; Stokes, C; Salyani, S; Alcalay, N; De Fiebre, N C; De Fiebre, C M

    2002-01-01

    The aim of this study was to develop a simple and reliable assay for nicotine (NIC) and its major metabolite, cotinine (COT), in plasma and brain. A method was developed that uses an extraction method compatible with reverse-phase high-performance liquid chromatography (HPLC) separation and ultraviolet (UV) detection. Sequential solid-phase extraction on silica columns followed by extraction using octadecyl (C18) columns resulted in mean percent recovery (n = 5) of 51 +/- 5, 64 +/- 10, and 52 +/- 10% for NIC, COT, and phenylimidazole (PI), respectively, in spiked 1-mL serum samples. Recovery (mean +/- SEM) of the internal standard (PI) from spiked samples of nicotine-injected rats averaged 64.1 +/- 1.5% (n = 138) from plasma, and 20.7+/-0.8% (n = 128) from brain. The limits of detection of NIC in plasma samples were approximately 8 ng per mL, and of COT, 13.6 ng per mL. Further optimization of our extraction method, using slower flow rates and solid-phase extraction on silica columns, followed by C18 column extraction, yielded somewhat better recoveries (38 +/-3%) for 1-mL brain homogenates. Interassay precision (coefficient of variation) was determined on the basis of daily calibrations for 2 months and was found to be 7%, 9%, and 9% for NIC, COT, and PI, respectively, whereas intra-assay variability was 3.9% for both NIC and COT. Limited studies were performed on analytical columns for comparison of retention, resolution, asymmetry, and column capacity. We concluded that a simple two-step solid-phase extraction method, coupled with HPLC separation and UV detection, can be used routinely to measure NIC and COT in biological fluids and tissues.

  11. Reversed-phase high-performance liquid chromatographic method for the determination of peptidoglycan monomers and structurally related peptides and adamantyltripeptides.

    Science.gov (United States)

    Krstanović, Marina; Frkanec, Ruza; Vranesić, Branka; Ljevaković, Durdica; Sporec, Vesna; Tomasić, Jelka

    2002-06-25

    The reversed-phase HPLC method using UV detection was developed for the determination of (a) immunostimulating peptidoglycan monomers represented by the basic structure GlcNAc-MurNAc-L-Ala-D-isoGln-meso-DAP(omegaNH(2))-D-Ala-D-Ala (PGM) and two more lipophilic derivatives, Boc-Tyr-PGM and (Ada-1-yl)-CH(2)-CO-PGM, (b) two diastereomeric immunostimulating adamantyltripeptides L- and D-(adamant-2-yl)-Gly-L-Ala-D-isoGln and (c) peptides obtained by the enzyme hydrolyses of peptidoglycans and related peptides. The enzymes used, N-acetylmuramyl-L-alanine amidase and an L,D-aminopeptidase are present in mammalian sera and are involved in the metabolism of peptidoglycans and related peptides. Appropriate solvent systems were chosen with regard to structure and lipophilicity of each compound. As well, different gradient systems within the same solvent system had to be applied in order to achieve satisfactory separation and retention time. HPLC separation was developed with the aim to use this method for the study of the stability of the tested compounds, the purity during preparation and isolation and for following the enzyme hydrolyses.

  12. Monitoring of chloropesticide methoxychlor preconcentration from waste water using hplc - solid phase extraction (abstract)

    International Nuclear Information System (INIS)

    Butt, S.B.; Saqlin, M.; Riaz, M.

    2011-01-01

    The method involves preconcentration of methoxychlor by solid phase extraction (SPE) with 1 mL silica based C-18 and 3 mL polymer based C-18 cartridge and then quantification by high performance liquid chromatography with UV detector (HPLC-UV). Optimization of HPLC parameters was done by determining max of methoxychlor on a double beam UV/Visible spectrophotometer, flow rate of mobile phase on reversed phase columns. Lowest detection limit for methoxychlor dissolved in water and methanol was 0.2ppm and 0.1ppm respectively. For solid phase extraction recovery studies and effect of different parameters such as initial concentration of analyte 0.01 to 0.05 ppm, loading rate 1 and 2mL/min, nature of desorbing solvent (methanol, ethyl acetate and acetonitrile) were investigated. Periodic self degradation of methoxychlor, and reusing potential of both SPE materials was also explored. Lower initial concentrations and slower loading rate of methoxychlor solutions gave improved recoveries. Recoveries were in the range of 80 to 90% for new SPE cartridge and reduced to 35 to 57% for once used silica based C-18 tubes. It was around 73 % for HLB C18 on their second use, and decreased on their repeated reuse. Lastly recoveries for stimulant and real waste water samples were determined to be 77 and 60% respectively. (author)

  13. Development and validation of an HPLC method for tetracycline-related USP monographs.

    Science.gov (United States)

    Hussien, Emad M

    2014-09-01

    A novel reversed-phase HPLC method was developed and validated for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline hydrochloride impurity in tetracycline hydrochloride commercial bulk and pharmaceutical products. The method employed L1 (3 µm, 150 × 4.6 mm) columns, a mobile phase of 0.1% phosphoric acid and acetonitrile at a flow rate of 1.0 mL/min, and detection at 280 nm. The separation was performed in HPLC gradient mode. Forced degradation studies showed that tetracycline eluted as a spectrally pure peak and was well resolved from its degradation products. The fast degradation of tetracycline hydrochloride and 4-epianhydrotetracycline hydrochloride in solution was retarded by controlling the autosampler temperature at 4 °C and using 0.1% H3 PO4 as diluent. The robustness of the method was tested starting with the maximum variations allowed in the US Pharmacopeia (USP) general chapter Chromatography . The method was linear over the range 80-120% of the assay concentration (0.1 mg/mL) for tetracycline hydrochloride and 50-150% of the acceptance criteria specified in the individual USP monographs for 4-epianhydrotetracycline hydrochloride. The limit of quantification for 4-epianhydrotetracycline hydrochloride was 0.1 µg/mL, 20 times lower than the acceptance criteria. The method was specific, precise, accurate and robust. Copyright © 2014 John Wiley & Sons, Ltd.

  14. RP-HPLC Method for the Estimation of Nebivolol in Tablet Dosage Form

    Directory of Open Access Journals (Sweden)

    M. K. Sahoo

    2009-01-01

    Full Text Available A reverse phase HPLC method is described for the determination of nebivolol in tablet dosage form. Chromatography was carried on a Hypersil ODS C18 column using a mixture of methanol and water (80:20 v/v as the mobile phase at a flow rate of 1.0 mL/min with detection at 282 nm. Chlorzoxazone was used as the internal standard. The retention times were 3.175 min and 4.158 min for nebivolol and chlorzoxazone respectively. The detector response was linear in the concentration of 1-400 μg/mL. The limit of detection and limit of quantification was 0.0779 and 0.2361 μg/mL respectively. The percentage assay of nebivolol was 99.974%. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control of nebivolol in bulk and tablet dosage form.

  15. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    Science.gov (United States)

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  16. Molecular-level characterization of crude oil compounds combining reversed-phase high-performance liquid chromatography with off-line high-resolution mass spectrometry

    Science.gov (United States)

    Sim, Arum; Cho, Yunju; Kim, Daae; Witt, Matthias; Birdwell, Justin E.; Kim, Byung Ju; Kim, Sunghwan

    2014-01-01

    A reversed-phase separation technique was developed in a previous study (Loegel et al., 2012) and successfully applied to the de-asphalted fraction of crude oil. However, to the best of our knowledge, the molecular-level characterization of oil fractions obtained by reversed-phase high-performance liquid chromatography (HPLC) coupled with high-resolution mass spectrometry (MS) has not yet been reported. A detailed characterization of the oil fractions prepared by reversed-phase HPLC was performed in this study. HPLC fractionation was carried out on conventional crude oil and an oil shale pyrolysate. The analyses of the fractions showed that the carbon number of alkyl chains and the double bond equivalent (DBE) value were the major factors determining elution order. The compounds with larger DBE (presumably more condensed aromatic structures) and smaller carbon number (presumably compounds with short side chains) were eluted earlier but those compounds with lower DBE values (presumably less aromatic structures) and higher carbon number (presumably compounds with longer alkyl chains) eluted later in the chromatograms. This separation behavior is in good agreement with that expected from the principles of reversed-phase separation. The data presented in this study show that reversed-phase chromatography is effective in separating crude oil compounds and can be combined with ultrahigh-resolution MS data to better understand natural oils and oil shale pyrolysates.

  17. Speciation of As(III) and As(V) in water and sediment using reverse-phase ion-pair high-performance liquid chromatography-neutron activation analysis (HPLC-NAA).

    Science.gov (United States)

    Tulasi, Delali; Adotey, Dennis; Affum, Andrews; Carboo, Derick; Serfor-Armah, Yaw

    2013-10-01

    Total As content and the As species distribution in water and sediments from the Kwabrafo stream, a major water body draining the Obuasi gold mining community in southwestern Ghana, have been investigated. Total As content was determined by instrumental neutron activation analysis (INAA). Ion-pair reverse phase high-performance liquid chromatography-neutron activation analysis (HPLC-NAA) was used for speciation of As species. Solid phase extraction with phosphate buffer was used to extract soluble As species from lyophilized sediment. The mass balance after phosphate extraction of soluble As species in sediment varied from 89 to 96 %. Compositionally appropriate reference material International Atomic Energy Agency (IAEA)-Lake Sediment (SL)-1 was used to check the validity of INAA method for total As determination. The measured values are in good agreement with the IAEA recommended value and also within the 95 % confidence interval. The accuracy of the measurement in terms of relative deviation from the IAEA recommended value was ±0.83 %. "In-house" prepared As(III) and As(V) standards were used to validate the HPLC-INAA method used for the As species determination. Total As concentration in the water samples ranged from 1.15 to 9.20 mg/L. As(III) species in water varied from 0.13 to 0.7 mg/L, while As(V) species varied from 0.79 to 3.85 mg/L. Total As content in sediment ranged from 2,134 to 3,596 mg/kg dry mass. The levels of As(III) and As(V) species in the sediment ranges from 138 to 506 mg/kg dry mass and 156 to 385 mg/kg dry mass, respectively.

  18. Development and validation of a RP–HPLC method for the quantization studies of metronidazole in tablets and powders dosage forms

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean,

    2011-12-01

    Full Text Available An isocratic high-performance liquid chromatography (HPLC procedure was developed for the quantitative determination of metronidazole in tablets and powders. HPLC separation was carried out by reversed phasechromatography on Kromasil C18 (250 mm x 4.6 mm i.e.; 5 ìm particle size, held in thermostat at 25°C. The mobile phase consisted of methanol/ 0.1% phosphoric acid aq. (20/80v/v, with a flow rate of 1 ml/min and with UV detection at 317 nm. In order to validate the method, the following parameters have been investigated: linearity (r2=0.9999, range, precision, accuracy, specificity, limit of detection and limit of quantification. The described method can be successfully applied for the analysis of the active pharmaceuticalcompound in tablets and powders. This paper aimed to develop and validate an HPLC sensitive applicable method to determine the quantity of metronidazole in tablets and powders, contributing to the quality and safety control of these types of pharmaceutical preparations.

  19. DETERMINATION OF RELATED IMPURITIES IN THE ANILOCAINE SUBSTANCE BY HPLC METHOD

    Directory of Open Access Journals (Sweden)

    D. R. Sabirzyanov

    2017-01-01

    Full Text Available Anilocaine is a local anesthetic from the group of substituted amides, synthesized in the Perm State Pharmaceutical Academy. Anilocaine shows high surface anesthetic, infiltration and conduction anesthesia and shows the high efficiency in the various fields of medical practice. The quality of produced medicines depends on the quality of pharmaceutical substances. The purity is one of the most important parameters of the quality of pharmaceutical substances. The aim of this work was the development and validation of methods for identification of specific impurities in the substance of anilocaine by high-performance liquid chromatography (HPLC. Materials and methods. Studies were performed on liquid chromatography LC-20 Prominence (Shimadzu, Japan equipped with a diode-array detector (SPD-M20A. Chromatographic column was Zorbax SB-C18 (4.6 mm × 250 mm, 5 μm. Validation assessment of the developed method conducted in accordance with the requirements of FP XIII and international requirementsICH (International Conference on Harmonization. Results and discussion. An experiment on the selection of the conditions of chromatographically showed that optimal separation of anilocaine and possible impurities (identified and unidentified by the method of reversed-phase HPLC is observed in isocratic mode, using an eluent based on phosphate buffer pH 3 and acetonitrile. The flow rate of mobile phase is 1 ml/min; wavelength detection is 210 nm. Time check chromatogram is 20 minutes. Conclusion. The method for the quantitative determination of impurities in the substance of anilocaine by high-performance liquid chromatography was developed as the result of the research. The validation procedure of the analytical methods established its specificity, linearity, precision and accuracy. This method is included in the project monograph on substance of anilocaine.

  20. [Determination of ciprofloxacin in human serum and urine by reversed-phase HPLC].

    Science.gov (United States)

    Qin, Y; Liang, D

    1993-03-01

    A sensitive and rapid method for the determination of ciprofloxacin using enoxacin as the internal standard was reported. High-performance liquid chromatograph model 344 (Beckman, USA) with a variable wavelength UV detector and reversed-phase Ultrasphere-ODS column (5 microns, 250 x 4.6 mm) was used. Serum or urine sample preparation involved addition phosphate buffer (pH 7.5) and aqueous solution of sodium lauryl sulfate, followed by chloroform extraction. The organic layer was removed and evaporated to dryness under an air stream in a 37 degrees C water bath. The residue was dissolved in 50 microliters mobile phase and 20 microliters injected. The mobile phase of 0.02 mol/L acetate buffer (pH 3.0) -acetonitril-dimethylformamide-10% aqueous solution of tetrabutyl ammonium hydroxide (88:6.5:5:0.5) was pumped at 0.9 ml/min through the column. The detector operated at 0.01 aufs and the wavelength was set at 276 nm. The retention times for ciprofloxacin and enoxacin were 7.31 min and 5.59 min, respectively. In serum, standard curve was linear in the concentration range of 0.75 to 24 mumol/L, the detective limit was 0.2 mumol/L, extraction recovery was 69-74%, within-day CV was less than 5%, and inter-day CV was less than 6%.

  1. Development and validation of reverse phase high performance liquid chromatography for citral analysis from essential oils.

    Science.gov (United States)

    Gaonkar, Roopa; Yallappa, S; Dhananjaya, B L; Hegde, Gurumurthy

    2016-11-15

    Citral is a widely used monoterpene aldehyde in aromatherapy, food and pesticide industries. A new validated reverse phase high performance liquid chromatography (RP - HPLC) procedure for the detection and quantification of cis-trans isomers of citral was developed. The RP-HPLC analysis was carried out using Enable C - 18G column (250×4.6mm, 5μ), with acetonitrile and water (70: 30) mobile phase in isocratic mode at 1mL/min flow. A photodiode array (PDA) detector was set at 233nm for the detection of citral. The method showed linearity, selectivity and accuracy for citral in the range of 3-100μg/mL. In order to compare the new RP-HPLC method with the available methods, one of the commercially available essential oil from Cymbopogon flexuosus was analyzed using new RP-HPLC method and the same was analyzed using GC-MS for the comparison of the method for the detection of citral. The GC-MS analysis was done using mass selective detector (MSD) showed citral content to be of 72.76%; wherein the new method showed to contain that same at 74.98%. To prove the application of the new method, essential oils were extracted from lemongrass, lemon leaves and mosambi peels by steam distillation. The citral content present in the essential and also in the condensate was analyzed. The method was found to be suitable for the analysis of citral in essential oils and water based citral formulations with a very good resolution of its components geranial and neral. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Reverse isotope dilution method for determining benzene and metabolites in tissues

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.

    1988-01-01

    A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of the radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue

  3. Simplified RP-HPLC method for multi-residue analysis of abamectin, emamectin benzoate and ivermectin in rice.

    Science.gov (United States)

    Xie, Xianchuan; Gong, Shu; Wang, Xiaorong; Wu, Yinxing; Zhao, Li

    2011-01-01

    A rapid, reliable and sensitive reverse-phase high-performance liquid chromatography method with fluorescence detection (RP-FLD-HPLC) was developed and validated for simultaneous analysis of the abamectin (ABA), emamectin (EMA) benzoate and ivermectin (IVM) residues in rice. After extraction with acetonitrile/water (2 : 1) with sonication, the avermectin (AVMs) residues were directly derivatised by N-methylimidazole (N-NMIM) and trifluoroacetic anhydride (TFAA) and then analysed on RP-FLD-HPLC. A good linear relationship (r(2 )> 0.99) was obtained for three AVMs ranging from 0.01 to 5 microg ml(-1), i.e. 0.01-5.0 microg g(-1) in rice matrix. The limit of detection (LOD) and the limit of quantification (LOQ) were between 0.001 and 0.002 microg g(-1) and between 0.004 and 0.006 microg g(-1), respectively. Recoveries were from 81.9% to 105.4% and precision less than 12.4%. The proposed method was successfully applied to routine analysis of the AVMs residues in rice.

  4. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  5. Chemometrics-Assisted UV Spectrophotometric and RP-HPLC Methods for the Simultaneous Determination of Tolperisone Hydrochloride and Diclofenac Sodium in their Combined Pharmaceutical Formulation.

    Science.gov (United States)

    Gohel, Nikunj Rameshbhai; Patel, Bhavin Kiritbhai; Parmar, Vijaykumar Kunvarji

    2013-01-01

    Chemometrics-assisted UV spectrophotometric and RP-HPLC methods are presented for the simultaneous determination of tolperisone hydrochloride (TOL) and diclofenac sodium (DIC) from their combined pharmaceutical dosage form. Chemometric methods are based on principal component regression and partial least-square regression models. Two sets of standard mixtures, calibration sets, and validation sets were prepared. Both models were optimized to quantify each drug in the mixture using the information included in the UV absorption spectra of the appropriate solution in the range 241-290 nm with the intervals λ = 1 nm at 50 wavelengths. The optimized models were successfully applied to the simultaneous determination of these drugs in synthetic mixture and pharmaceutical formulation. In addition, an HPLC method was developed using a reversed-phase C18 column at ambient temperature with a mobile phase consisting of methanol:acetonitrile:water (60:30:10 v/v/v), pH-adjusted to 3.0, with UV detection at 275 nm. The methods were validated in terms of linearity, accuracy, precision, sensitivity, specificity, and robustness in the range of 3-30 μg/mL for TOL and 1-10 μg/mL for DIC. The robustness of the HPLC method was tested using an experimental design approach. The developed HPLC method, and the PCR and PLS models were used to determine the amount of TOL and DIC in tablets. The data obtained from the PCR and PLS models were not significantly different from those obtained from the HPLC method at 95% confidence limit.

  6. Reversed-phase HPLC analysis of levetiracetam in tablets using monolithic and conventional C18 silica columns.

    Science.gov (United States)

    Can, Nafiz O; Arli, Goksel

    2010-01-01

    Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.

  7. Application of artificial neural networks for response surface modelling in HPLC method development

    Directory of Open Access Journals (Sweden)

    Mohamed A. Korany

    2012-01-01

    Full Text Available This paper discusses the usefulness of artificial neural networks (ANNs for response surface modelling in HPLC method development. In this study, the combined effect of pH and mobile phase composition on the reversed-phase liquid chromatographic behaviour of a mixture of salbutamol (SAL and guaiphenesin (GUA, combination I, and a mixture of ascorbic acid (ASC, paracetamol (PAR and guaiphenesin (GUA, combination II, was investigated. The results were compared with those produced using multiple regression (REG analysis. To examine the respective predictive power of the regression model and the neural network model, experimental and predicted response factor values, mean of squares error (MSE, average error percentage (Er%, and coefficients of correlation (r were compared. It was clear that the best networks were able to predict the experimental responses more accurately than the multiple regression analysis.

  8. A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2011-01-01

    Full Text Available This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid in Meropenem active pharmaceutical ingredient (API. EDTA was derivatized with Ferric chloride solution by heating at 70 ° C in water bath for about 20 minutes and the chromatographic separation achieved by injecting 100 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a Phenomenex Luna C18(2 column (250 × 4.6 mm, 5 μ, The mobile phase consisting of 5% methanol and 95% of 0.7 g/L solution of Tetra butyl ammonium bromide and 4.6 g/L solution of sodium acetate trihydrate in water (pH adjusted to 4.0 with the help of acetic acid glacial and a flow rate of 1 milliliter/minute. EDTA eluted at approximately 6 minutes. The method was suitably validated with respect to specificity, linearity of response, precision, accuracy, ruggedness, stability in analytical solution, limit of quantitation and detection and robustness for its intended use.

  9. Simultaneous determination of related substances of telmisartan and hydrochlorothiazide in tablet dosage form by using reversed phase high performance liquid chromatographic method

    Directory of Open Access Journals (Sweden)

    Sutirtho Mukhopadhyay

    2011-01-01

    Full Text Available Objective : Telmisartan is a potent, long-lasting, nonpeptide antagonist of the angiotensin II type-1 (AT 1 receptor that is indicated for the treatment of essential hypertension. Hydrochlorothiazide is a widely prescribed diuretic and it is indicated for the treatment of edema, control of essential hypertension and management of diabetes insipidus. In the current article a new, accurate, sensitive, precise, rapid, reversed phase high performance liquid chromatography (RP-HPLC method was developed for determination of related substances of Telmisartan and Hydrochlorthiazide in tablet dosage form. Materials and Methods : Simultaneous determination of related substances was performed on Kromasil C 18 analytical column (250 × 4.6 mm; 5΅m pertical size column at 40°C employing a gradient elution. Mobile phase consisting of solvent A (solution containing 2.0 g of potassium dihydrogen phosphate anhydrous and 1.04 g of Sodium 1- Hexane sulphonic acid monohydrate per liter of water, adjusted to pH 3.0 with orthophosphoric acid and solvent B (mixture of Acetonitrile: Methanol in the ratio 80:20 v/v was used at a flow rate of 1.0 ml min−1 . UV detection was performed at 270 nm. Results : During method validation parameter such as precision, linearity, accuracy, specificity, limit of detection and quantification were evaluated, which remained within acceptable limits. Conclusions : HPLC analytical method is linear, accurate, precise, robust and specific, being able to separate the main drug from its degradation products. It may find application for the routine analysis of the related substances of both Telmisartan and Hydrochlorthiazide in this combination tablets.

  10. Analytical method development and validation of simultaneous estimation of rabeprazole, pantoprazole, and itopride by reverse-phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Senthamil Selvan Perumal

    2014-12-01

    Full Text Available A simple, selective, rapid, and precise reverse-phase high-performance liquid chromatography (RP-HPLC method for the simultaneous estimation of rabeprazole (RP, pantoprazole (PP, and itopride (IP has been developed. The compounds were well separated on a Phenomenex C18 (Luna column (250 mm × 4.6 mm, dp = 5 μm with C18 guard column (4 mm × 3 mm × 5 μm with a mobile phase consisting of buffer containing 10 mM potassium dihydrogen orthophosphate (adjusted to pH 6.8: acetonitrile (70:30 v/v at a flow rate of 1.0 mL/min and ultraviolet detection at 288 nm. The retention time of RP, PP, and IP were 5.35, 7.92, and 11.16 minutes, respectively. Validation of the proposed method was carried out according to International Conference on Harmonisation (ICH guidelines. Linearity range was obtained for RP, PP, and IP over the concentration range of 2.5–25, 1–30, and 3–35 μg/mL and the r2 values were 0.994, 0.978, and 0.991, respectively. The calculated limit of detection (LOD values were 1, 0.3, and 1 μg/mL and limit of quantitation (LOQ values were 2.5, 1, and 3 μg/mL for RP, PP, and IP correspondingly. Thus, the current study showed that the developed reverse-phase liquid chromatography method is sensitive and selective for the estimation of RP, PP, and IP in combined dosage form.

  11. Analytical method development and validation of simultaneous estimation of rabeprazole, pantoprazole, and itopride by reverse-phase high-performance liquid chromatography.

    Science.gov (United States)

    Perumal, Senthamil Selvan; Ekambaram, Sanmuga Priya; Raja, Samundeswari

    2014-12-01

    A simple, selective, rapid, and precise reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of rabeprazole (RP), pantoprazole (PP), and itopride (IP) has been developed. The compounds were well separated on a Phenomenex C 18 (Luna) column (250 mm × 4.6 mm, dp = 5 μm) with C 18 guard column (4 mm × 3 mm × 5 μm) with a mobile phase consisting of buffer containing 10 mM potassium dihydrogen orthophosphate (adjusted to pH 6.8): acetonitrile (70:30 v/v) at a flow rate of 1.0 mL/min and ultraviolet detection at 288 nm. The retention time of RP, PP, and IP were 5.35, 7.92, and 11.16 minutes, respectively. Validation of the proposed method was carried out according to International Conference on Harmonisation (ICH) guidelines. Linearity range was obtained for RP, PP, and IP over the concentration range of 2.5-25, 1-30, and 3-35 μg/mL and the r 2 values were 0.994, 0.978, and 0.991, respectively. The calculated limit of detection (LOD) values were 1, 0.3, and 1 μg/mL and limit of quantitation (LOQ) values were 2.5, 1, and 3 μg/mL for RP, PP, and IP correspondingly. Thus, the current study showed that the developed reverse-phase liquid chromatography method is sensitive and selective for the estimation of RP, PP, and IP in combined dosage form. Copyright © 2014. Published by Elsevier B.V.

  12. Stability indicating RP-HPLC method for simultaneous determination of pantoprazole sodium and itopride hydrochloride in bulk and capsule

    Directory of Open Access Journals (Sweden)

    Krishna R. Gupta

    2011-03-01

    Full Text Available A stability indicating reversed-phase HPLC method has been developed and subsequently validated for simultaneous estimation of pantoprazole present as pantoprazole sodium sesquihydrate (PSS, and itopride hydrochloride from their combination product. The proposed RP-HPLC method utilizes a Phenomenex® C18, 5 µm, 250 mm X 4.6 mm i.d. column, mobile phase consisting of phosphate buffer and acetonitrile in the proportion of 55:45 (v/v with apparent pH adjusted to 5.0, and UV detection at 289.0 nm using a UV detector. PAN, ITH and their combination drug product were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 4-20 µg/mL for PAN and 15-75 µg/mL for ITH. The mean recoveries were 100.02 and 99.88 for PAN and ITH, respectively. Chromatographic peak purity data of PAN and ITH indicated no co-eluting peaks with the main peaks of drugs which demonstrated the specificity of assay method for their estimation in presence of degradation products. The proposed method can be useful in the quality control of combination drug products.

  13. Theoretical aspects of gradient reversed-phase high performance liquid chromatography of styrene-butylacrylate block copolymers

    NARCIS (Netherlands)

    Kolarova, L.; Jandera, P.; Vonk, E.C.; Claessens, H.A.

    2004-01-01

    Butylacrylate – styrene co-polymers prepared by atom transfer radical polymeratization were separated on an octadecyl silica column by gradient elution with tetrahydrofuran in water, up to the molar masses 10,000. In reversed-phase high performance liquid chromatography (RP-HPLC), the retention of

  14. Optimalizace HPLC metody pro separaci tetracyklinových antibiotik

    OpenAIRE

    Kučerová, Gabriela

    2011-01-01

    The aim of this work is to develop and to optimize HPLC method for separation of a set of four tetracycline antibiotics - tetracycline, chlortetracycline, oxytetracycline, and doxycycline. Four different reversed octadecyl-silica stationary phases in various mobile phase compositions were examined in isocratic elution. The baseline resolution of all the analytes was obtained by using two columns - Astec C18 and Atlantis C18 I. The optimized separation system consisted of Atlantis C18 I. colum...

  15. Development of a new rapid HPLC method for the fractionation of histones

    International Nuclear Information System (INIS)

    Gurley, L.R.; Valdez, J.G.; Prentice, D.A.; Spall, W.D.

    1983-01-01

    To study histone functions, it is necessary to fractionate the histones into their five classes (H1, H2A, H2B, H3 and H4) and then to subfractionate these classes into variants having slightly different primary structures and into different phosphorylated and acetylated forms. With the advent of high-performance liquid chromatography (HPLC), it was hoped that laborious and time-consuming conventional methods could be replaced by a simple, rapid, high-resolving HPLC method for fractionating histones. However, problems of irreversible adsorption of the histones to HPLC column packings discouraged this development. Our laboratory has now determined that the strong adsorption of histones to HPLC columns results from two different forces: (1) polar interactions between the histones and the silanol groups of silica-based HPLC column packing, and (2) hydrophobic interactions between the histones and the bound organic phase of the column packings. By minimizing these forces, we have succeeded in developing an HPLC method suitable for histone studies

  16. Reverse phase high performance liquid chromatographic method development based on ultravioletvisible detector for the analysis of 1-hydroxypyrene (PAH biomarker) in human urine.

    Science.gov (United States)

    Kamal, Atif; Gulfraz, Mohammad; Anwar, Mohammad Asad; Malik, Riffat Naseem

    2015-01-01

    1-hydroxypyrene is an important biomarker of exposure to polycyclic aromatic hydrocarbons (PAHs), which appears in the urine of exposed human subjects. In developing countries, where advanced instruments are not available, the importance of this biomarker demands convenient and sensitive methods for determination purposes. This study aimed at developing a methodology to quantify 1-hydroxypyrene (a biomarker of PAHs exposure) based on the UV-visible detector in the reverse phase high pressure liquid chromatography (HPLC). A 20 μl injection of sample was used for manual injection into the HPLC Shimadzu, equipped with the SPD-20 A UV-visible detector, the LC-20AT pump and the DGU-20A5 degasser. The C-18 column was used for the purpose of the analysis. The method showed a good linearity (the range: R2 = 0.979-0.989), and high detectability up to the nmol level. The average retention was 6.37, with the accuracy of 2%, and the percentage of recovery remained 108%. The overall performance of this method was comparable (in terms of detection sensitivity) and relatively better than previously reported studies using the HPLC system equipped with the UV-detector. This method is suitable and reliable for the detection/quantification of the 1-OHP in human urine samples, using the UV-detector, however, it is less sensitive as compared to the results of a florescence detector. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. HPLC-DAD determination of imidacloprid in onion

    OpenAIRE

    Mandić Aljoša; Lazić Sanja; Inđić Dušanka

    2003-01-01

    Imidacloprid is an insecticide most commonly used on vegetables, potato sugar beet, fruit, cereal, maize and rice. Imidacloprid residue has been determined in spiked onion and in onion samples. Sample preparation consisted of dichlormethane extraction of imidacloprid from onion, followed by purification of the obtained extract on a LC-Florisil disposable cartridge. The HPLC-DAD method bas been developed on reversed-phase for separation of imidacloprid with a mixture of 0.01 M phosphate buffer...

  18. Simultaneous determination of F-beta-alanine and beta-alanine in plasma and urine with dual-column reversed-phase high-performance liquid chromatography

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; Stroomer, A. E.; Peters, G. J.; van Gennip, A. H.

    2001-01-01

    F-beta-Alanine and beta-alanine were detected in plasma and urine samples with fluorescence detection of orthophthaldialdehyde derivatives of F-beta-alanine and beta-alanine after separation with dual-column reversed-phase HPLC. The detection limits of F-beta-alanine and beta-alanine in the HPLC

  19. Stability Indicating HPLC Method for Simultaneous Quantification of Trihexyphenidyl Hydrochloride, Trifluoperazine Hydrochloride and Chlorpromazine Hydrochloride from Tablet Formulation

    Directory of Open Access Journals (Sweden)

    P. Shetti

    2010-01-01

    Full Text Available A new, simple, precise, rapid, selective and stability indicating reversed-phase high performance liquid chromatographic (HPLC method has been developed and validated for simultaneous quantification of trihexyphenidyl hydrochloride, trifluoperazine hydrochloride and chlorpromazine hydrochloride from combined tablet formulation. The method is based on reverse-phase using C-18 (250×4.6 mm, 5 μm particle size column. The separation is achieved using isocratic elution by methanol and ammonium acetate buffer (1% w/v, pH 6.5 in the ratio of 85:15 v/v, pumped at flow rate 1.0 mL/min and UV detection at 215 nm. The column is maintained at 30 °C through out the analysis. This method gives baseline resolution. The total run time is 15 min. Stability indicating capability is established buy forced degradation experiment. The method is validated for specificity, accuracy, precision and linearity as per International conference of harmonisation (ICH. The method is accurate and linear for quantification of trihexyphenidyl hydrochloride, trifluoperazine hydrochloride and Chlorpromazine hydrochloride between 5 - 15 μg/mL, 12.5- 37.5 μg/mL and 62.5 - 187.5 μg/mL respectively.

  20. Measurements of urinary kinins by HPLC-radioimmunoassay

    International Nuclear Information System (INIS)

    Fejes-Toth, G.; Naray-Fejes-Toth, A.; Froelich, J.C.

    1984-01-01

    In this paper the authors describe a method for the individual determination of urinary kinins. Extraction from the urine is performed on an Amberlite CG-50 column and kinins are eluted with formic acid. The samples are further purified and kinins are separated by reversed phase HPLC. Bradykinin and lysylbradykinin are quantified by a sensitive radioimmunoassay capable of detecting 0.1 fmol of either peptide. Procedural losses are monitored by measuring the recovery of [ 3 H]bradykinin and [ 3 H]lysylbradykinin. Simple methods for labeling of bradykinin and lysylbradykinin with tritium are also presented. Recoveries of [ 3 H]bradykinin and [ 3 H]lysylbradykinin from biological material ranged between 77 and 91%. The combination of HPLC with radioimmunoassay makes it possible to determine kinin concentrations of biological samples with a higher sensitivity and greater specificity than previous methods. (Auth.)

  1. Characterizing the selectivity of stationary phases and organic modifiers in reversed-phase high-performance liquid chromatographic systems by a general solvation equation using gradient elution.

    Science.gov (United States)

    Du, C M; Valko, K; Bevan, C; Reynolds, D; Abraham, M H

    2000-11-01

    Retention data for a set of 69 compounds using rapid gradient elution are obtained on a wide range of reversed-phase stationary phases and organic modifiers. The chromatographic stationary phases studied are Inertsil (IN)-ODS, pentafluorophenyl, fluoro-octyl, n-propylcyano, Polymer (PLRP-S 100), and hexylphenyl. The organic solvent modifiers are 2,2,2-trifluoroethanol (TFE); 1,1,1,3,3,3-hexafluoropropan-2-ol (HFIP); isopropanol; methanol (MeOH); acetonitrile (AcN); tetrahydrofuran; 1,4-dioxane; N,N-dimethylformamide; and mixed solvents of dimethylsulfoxide (DMSO) with AcN and DMSO with MeOH (1:1). A total of 25 chromatographic systems are analyzed using a solvation equation. In general, most of the systems give reasonable statistics. The selectivity of the reversed phase-high-performance liquid chromatographic (HPLC) systems with respect to the solute's dipolarity-polarity, hydrogen-bond acidity, and basicity are reflected in correspondingly large coefficients in the solvation equation. We wanted to find the most orthogonal HPLC systems, showing the highest possible selectivity difference in order to derive molecular descriptors using the gradient retention times of a compound. We selected eight chromatographic systems that have a large range of coefficients of interest (s, a, and b) similar to those found in water-solvent partitions used previously to derive molecular descriptors. The systems selected are IN-ODS phases with AcN, MeOH, TFE, and HFIP as mobile phase, PLRP-S 100 phase with AcN, propylcyano phase with AcN and MeOH, and fluorooctyl phase with TFE. Using the retention data obtained for a compound in the selected chromatographic systems, we can estimate the molecular descriptors with the faster and simpler gradient elution method.

  2. Simultaneous determination of secondary metabolites from Vinca rosea plant extractives by reverse phase high performance liquid chromatography

    Science.gov (United States)

    Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari; Saidan, Noor Hafizoh

    2011-01-01

    Background: Vinca rosea (Apocynaceae) is one of the most important and high value medicinal plants known for its anticancer alkaloids. It is the iota of the isolated secondary metabolites used in chemotherapy to treat diverse cancers. Several high performance liquid chromatography (HPLC) methods have been developed to quantify the active alkaloids in the plant. However, this method may serve the purpose in quantification of V. rosea plant extracts in totality. Objective: To develop and validate the reverse phase (RP)-HPLC method for simultaneous determination of secondary metabolites, namely alkaloids from V. rosea plant extracts. Materials and Methods: The quantitative determination was conducted by RP-HPLC equipped with ultraviolet detector. Optimal separation was achieved by isocratic elution with mobile phase consisting of methanol:acetonitrile:ammonium acetate buffer (25 mM) with 0.1% triethylamine (15:45:40 v/v) on a column (Zorbax Eclipse plus C18, 250 mm % 4.6 mm; 5 μm). The standard markers (vindoline, vincristine, catharanthine, and vinblastine) were identified by retention time and co-injected with reference standard and quantified by external standard method at 297 nm. Results: The precision of the method was confirmed by the relative standard deviation (R.S.D.), which was lower than 2.68%. The recoveries were in the range of 98.09%-108%. The limits of detection (LOD) for each marker alkaloids were lower than 0.20 μg. Different parts of the V. rosea extracts shows different concentrations of markers, flower samples were high in vinblastine content, while methanol extract from the leaves contains all the four alkaloids in good yield, and there is no significant presence of markers in water extracts. Conclusion: HPLC method established is appropriate for the standardization and quality assurance of V. rosea plant extracts. PMID:21716929

  3. A Comparative Evaluation of Methods for the Determination of ...

    African Journals Online (AJOL)

    Ultraviolet/Visible (UV/Vis) methods, a normal phase High Pressure Liquid Chromatographic (HPLC) method and a reverse phase HPLC method for vitamin A were compared and subsequently used to analyze samples of margarine, edible oil milk and milk drinks purchased from the Abule Egba and Oke Odo market in ...

  4. A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.

    Science.gov (United States)

    Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca

    2005-02-15

    A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.

  5. A validated stability-indicating RP-HPLC method for paracetamol and lornoxicam: Application to pharmaceutical dosage forms

    Directory of Open Access Journals (Sweden)

    Karunakaran Kulandaivelu

    2014-01-01

    Full Text Available A new method for the simultaneous determination of paracetamol (PR and lornoxicam (LR has been developed by reversed phase HPLC from the combination drug product. The separation achieved on C18 column using acetonitrile and 0.02 M potassium dihydrogen phosphate was in the ratio of 35:65 (v/v as mobile phase at a flow rate of 1.0 mL/min. Both the components were monitored at a single wavelength at 260 nm and the column temperature was maintained at 30°C throughout the analysis. A linear response was found in the concentration range of 125-375 μg/mL for PR and 2-6 μg/mL for LR, with the correlation coefficient of more than 0.999. Although the tablet contained a high dose of PR (500 mg and a low dose of LR (8 mg, the single HPLC method was developed and the intra as well as inter day precision was obtained at less than 2% of RSD. The accuracy results obtained were between 98% and 102%. The drug was intentionally degraded under acidic, basic, peroxide, thermal, and photolytic conditions. The major degradation observed for both PR and LR under peroxide condition indicated that the drug product is susceptible to oxidation. The degraded peaks were properly resolved from PR and LR. Hence, the method is stability indicating.

  6. Multiresidue confirmatory method for determination of quinolones in milk by HPLC: method development and validation according to the criteria of Commission Decision 2002/657/EC

    Directory of Open Access Journals (Sweden)

    Federica Ostorero

    2013-04-01

    Full Text Available Veterinary drugs have become an integral part of the livestock production and play an important role in maintaining animal welfare. The use of veterinary medicines may be cause of the presence of drug residues in animal food products if appropriate withdrawal periods are not respected or if contaminated feeds are used. This work presents the development of an high performance liquid chromatography with postcolumn fluorescence derivatization (HPLC-FLD method for the quantitative detection of eight quinolones – norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, oxolinic acid, nalidixic acid, and flumequine – in bovine milk. After deproteination and extraction with a metaphosphoric acid 1% w/v/methanol/acetonitrile (60/20/20 v/v/v solution, the sample is partially evaporated and cleaned up on a reversed phase solid phase extraction (SPE cartridge. The extract is analyzed using an HPLC-FLD. Mean recovery ranged between 65-88%. The method is validated as a confirmatory method according to Decision 2002/657/EC. All the verified parameters (linearity, selectivity/specificity, trueness, precision, CC, ruggedness and stability were satisfactory and the method is able to quantify all the analytes in milk in the concentration range 15-60 μg/Kg for danofloxacin and 25-150 μg/Kg for the other quinolones.

  7. Utility of reversed phase high performance liquid chromatography for on-line yield determination of radiochemical separations: Studies with cobalt

    International Nuclear Information System (INIS)

    Subramanian, S.; Woittiez, J.R.W.

    1993-01-01

    This article indicates the potentials of high performance liquid chromatography (HPLC) as a radiochemical technique for multielement separation of neutron irradiated samples. The focus lies on the convenience to use the detector signal of the eluted components to indicate the chemical yield of the analyte, which has often proved to be a crucial step in radiochemical separations. Two signals have been utilized. The UV signal of the metal-ligand complexes separated by reversed phase HPLC and the radioactive response as a result of sample irradiation of carrier-tracer addition. Change in ratio is discussed between the two signals, if any, for a specific sample. Losses of metal as much as 65% were simulated and corrected using the individual UV response. The method promises improved accuracy for elemental analysis despite losses suffered during the various chemical steps. The procedure omits the necessity of additional analytical steps for yield determination. The present article aims at the chromatographic part of the study. Cobalt as cobalt diethyldithiocarbamate has been used to demonstrate the viability of the concept. The separation was developed on c C18 reverse phase analytical column and optimized on a semi preparative one

  8. A Validated Reverse Phase HPLC Analytical Method for Quantitation of Glycoalkaloids in Solanum lycocarpum and Its Extracts

    Directory of Open Access Journals (Sweden)

    Renata Fabiane Jorge Tiossi

    2012-01-01

    Full Text Available Solanum lycocarpum (Solanaceae is native to the Brazilian Cerrado. Fruits of this species contain the glycoalkaloids solasonine (SN and solamargine (SM, which display antiparasitic and anticancer properties. A method has been developed for the extraction and HPLC-UV analysis of the SN and SM in different parts of S. lycocarpum, mainly comprising ripe and unripe fruits, leaf, and stem. This analytical method was validated and gave good detection response with linearity over a dynamic range of 0.77–1000.00 μg mL−1 and recovery in the range of 80.92–91.71%, allowing a reliable quantitation of the target compounds. Unripe fruits displayed higher concentrations of glycoalkaloids (1.04% ± 0.01 of SN and 0.69% ± 0.00 of SM than the ripe fruits (0.83% ± 0.02 of SN and 0.60% ± 0.01 of SM. Quantitation of glycoalkaloids in the alkaloidic extract gave 45.09% ± 1.14 of SN and 44.37% ± 0.60 of SM, respectively.

  9. Development and validation of HPLC analytical method for quantitative determination of metronidazole in human plasma

    International Nuclear Information System (INIS)

    Safdar, K.A.; Shyum, S.B.; Usman, S.

    2016-01-01

    The objective of the present study was to develop a simple, rapid and sensitive reversed-phase high performance liquid chromatographic (RP-HPLC) analytical method with UV detection system for the quantitative determination of metronidazole in human plasma. The chromatographic separation was performed by using C18 RP column (250mm X 4.6mm, 5 meu m) as stationary phase and 0.01M potassium dihydrogen phosphate buffered at pH 3.0 and acetonitrile (83:17, v/v) as mobile phase at flow rate of 1.0 ml/min. The UV detection was carried out at 320nm. The method was validated as per the US FDA guideline for bioanalytical method validation and was found to be selective without interferences from mobile phase components, impurities and biological matrix. The method found to be linear over the concentration range of 0.2812 meu g/ml to 18.0 meu g/ml (r2 = 0.9987) with adequate level of accuracy and precision. The samples were found to be stable under various recommended laboratory and storage conditions. Therefore, the method can be used with adequate level of confidence and assurance for bioavailability, bioequivalence and other pharmacokinetic studies of metronidazole in human. (author)

  10. A simple RP-HPLC method for related substances of zoledronic acid in pharmaceutical products

    Directory of Open Access Journals (Sweden)

    L. Maheswara Reddy

    2017-02-01

    Full Text Available A novel, selective and sensitive reverse phase-high performance liquid chromatography (RP-HPLC method has been developed for the validated estimation of imidazol-1-yl-acetic acid in zoledronic acid formulations. The separation was achieved on a 5 μ C18 column (250 × 4.6 mm using a mobile phase that consists of the buffer (4.5 g of di-potassium hydrogen phosphate anhydrous and 2.0 g of tetra butyl ammonium hydrogen sulphate (TBAHS in 1000 mL of water and methanol in the ratio of 900:100 v/v. The flow rate was maintained at 1.0 mL min−1. The detection of the constituents was done at 215 nm using a UV detector. The retention times of imidazol-1-yl-acetic acid and zoledronic acid were 7.2 and 10.2 min respectively. Recovery studies were satisfactory and the correlation coefficient, 0.999 indicates linearity of the method within the limits. The developed method can be applicable for regular qualitative analysis.

  11. Simultaneous determination of linagliptin and metformin by reverse phase-high performance liquid chromatography method: An application in quantitative analysis of pharmaceutical dosage forms

    Directory of Open Access Journals (Sweden)

    Prathyusha Vemula

    2015-01-01

    Full Text Available To enhance patient compliance toward treatment in diseases like diabetes, usually a combination of drugs is prescribed. Therefore, an anti-diabetic fixed-dose combination of 2.5 mg of linagliptin 500 mg of metformin was taken for simultaneous estimation of both the drugs by reverse phase-high performance liquid chromatography (RP-HPLC method. The present study aimed to develop a simple and sensitive RP-HPLC method for the simultaneous determination of linagliptin and metformin in pharmaceutical dosage forms. The chromatographic separation was designed and evaluated by using linagliptin and metformin working standard and sample solutions in the linearity range. Chromatographic separation was performed on a C 18 column using a mobile phase of 70:30 (v/v mixture of methanol and 0.05 M potassium dihydrogen orthophosphate (pH adjusted to 4.6 with orthophosphoric acid delivered at a flow rate of 0.6 mL/min and UV detection at 267 nm. Linagliptin and metformin shown linearity in the range of 2-12 μg/mL and 400-2400 μg/mL respectively with correlation co-efficient of 0.9996 and 0.9989. The resultant findings analyzed for standard deviation (SD and relative standard deviation to validate the developed method. The retention time of linagliptin and metformin was found to be 6.3 and 4.6 min and separation was complete in <10 min. The method was validated for linearity, accuracy and precision were found to be acceptable over the linearity range of the linagliptin and metformin. The method was found suitable for the routine quantitative analysis of linagliptin and metformin in pharmaceutical dosage forms.

  12. A rapid monitoring method for inorganic arsenic in rice flour using reversed phase-high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg

    2017-01-06

    A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO 3 -H 2 O 2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    OpenAIRE

    Adi-Dako, Ofosua; Oppong Bekoe, Samuel; Ofori-Kwakye, Kwabena; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5??m, 4.6 ? 150?mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol?:?water?:?acetic acid (60?:?30?:?10, v/v/v) at ...

  14. Isolation and quantitation of metallothionein isoforms using reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Richards, M.P.; Darcey, S.E.; Steele, N.C.

    1986-01-01

    Reversed-phase HPLC (RP-HPLC) was used to isolate and quantify metallothionein (MT) isoforms from a variety of animal species and tissues. Separations were performed on C 18 radially compressed cartridge columns, eluted with a 2-step linear gradient of acetonitrile in 10 mM sodium phosphate, pH 7.0. Isoforms were detected by UV absorbance (214 nm) and by on-line interfacing with an atomic absorption spectrophotometer (HPLC-AA) to determine bound Zn, Cd and Cu. Rabbit liver and horse kidney MT's exhibited 7 distinct peaks on RP-HPLC, 2 of which were predominant (MT1 and 2). Pig liver and kidney MT2 yielded 2 subspecies on RP-HPLC, while MT1 yielded a single peak. Avian liver MT was unique from mammalian MT's in that MT2 was about tenfold more abundant than MT1. RP-HPLC and HPLC-AA were used to isolate and quantitate MT isoforms and their Zn content directly from cytosol. Quantitation was achieved by peak area integration and extrapolation from a standard curve of purified avian liver MT2. Both RP-HPLC and HPLC-AA had a lower detection limit of 1 + g of peptide and .1 μg of Zn. Recoveries (92-98%) were determined with labeled ( 35 S) MT and MT of known Zn content. Cytoplasmic MT-Zn in avian embryo hepatocytes cultured with added Zn was quantitated using HPLC-AA. In conclusion, both RP-HPLC and HPLC-AA are rapid and powerful separation techniques for the isolation, quantitation and characterization of the isoproteins comprising the MT gene family

  15. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    Science.gov (United States)

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  16. An industry consensus study on an HPLC fluorescence method for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products.

    Science.gov (United States)

    Shumow, Laura; Bodor, Alison

    2011-07-05

    This manuscript describes the results of an HPLC study for the determination of the flavan-3-ol monomers, (±)-catechin and (±)-epicatechin, in cocoa and plain dark and milk chocolate products. The study was performed under the auspices of the National Confectioners Association (NCA) and involved the analysis of a series of samples by laboratories of five member companies using a common method. The method reported in this paper uses reversed phase HPLC with fluorescence detection to analyze (±)-epicatechin and (±)-catechin extracted with an acidic solvent from defatted cocoa and chocolate. In addition to a variety of cocoa and chocolate products, the sample set included a blind duplicate used to assess method reproducibility. All data were subjected to statistical analysis with outliers eliminated from the data set. The percent coefficient of variation (%CV) of the sample set ranged from approximately 7 to 15%. Further experimental details are described in the body of the manuscript and the results indicate the method is suitable for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products and represents the first collaborative study of this HPLC method for these compounds in these matrices.

  17. Structure-retention and mobile phase-retention relationships for reversed-phase high-performance liquid chromatography of several hydroxythioxanthone derivatives in binary acetonitrile-water mixtures

    International Nuclear Information System (INIS)

    Amiri, Ali Asghar; Hemmateenejad, Bahram; Safavi, Afsaneh; Sharghi, Hashem; Beni, Ali Reza Salimi; Shamsipur, Mojtaba

    2007-01-01

    The reversed-phase high-performance liquid chromatographic (RP-HPLC) behavior of some newly synthesized hydroxythioxanthone derivatives using binary acetonitrile-water mixtures as mobile phase has been examined. First, the variation in the retention time of each molecule as a function of mobile phase properties was studied by Kamlet-Taft solvatochromic equations. Then, the influences of molecular structure of the hydroxythioxanthone derivatives on their retention time in various mobile phase mixtures were investigated by quantitative structure-property relationship (QSPR) analysis. Finally, a unified model containing both the molecular structure parameters and mobile phase properties was developed to describe the chromatographic behavior of the systems studied. Among the solvent properties, polarity/polarizability parameter (π * ) and hydrogen-bond basicity (β), and among the solute properties, the most positive local charge (MPC), the sum of positive charges on hydrogen atoms contributing in hydrogen bonding (SPCH) and lipophilicity index (log P) were identified as controlling factors in the RP-HPLC behavior of hydroxythioxanthone derivatives in actonitrile-water binary solvents

  18. Analysis of metallic nanoparticles and their ionic counterparts in complex matrix by reversed-phase liquid chromatography coupled to ICP-MS.

    Science.gov (United States)

    Yang, Yuan; Luo, Li; Li, Hai-Pu; Wang, Qiang; Yang, Zhao-Guang; Qu, Zhi-Peng; Ding, Ru

    2018-05-15

    Developing quantification and characterization methodology for metallic nanoparticles (MNPs) and their ionic component in complex matrix are crucial for the evaluation of their environmental behavior and health risks to humans. In this study, reversed phase high performance liquid chromatography combined ICP-MS was established for the characterization of MNPs in complex matrix. The ionic component could be separated from NPs with the optimized parameters of aqueous mobile phase. Good linear relationship between average diameter and retention time of NPs was obtained using HPLC-ICP-MS and the size smaller than 40 nm could be determined with this method, the detected results were in accordance with TEM results. The low detection limit of AuNPs and Au(Ⅲ) (both in sub-μg/L level) showed that this method was promising for the characterization of AuNPs and Au(Ⅲ) in environmental water. The mass concentration of ionic Au(Ⅲ) in environmental water could be detected using the proposed HPLC-ICP-MS and the concentration of AuNPs was obtained by subtracting the Au(Ⅲ) concentration from the total Au (The concentration of total Au was detected by ICP-MS after microwave digestion). Furthermore this proposed HPLC-ICP-MS method and single particle-ICPMS (SP-ICP-MS) was used for the analysis of the Ag speciation in commercial antibacterial products. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. High-performance liquid chromatography using reversed-phase stationary phases dynamically modified with organophosphorus compound for the separation and determination of lanthanoid elements

    International Nuclear Information System (INIS)

    Tsuyoshi, Akira; Akiba, Kenichi

    2000-01-01

    An acidic organophosphorus compound, 2-ethylhexylphosphonic acid mono-2-ethlhexyl ester (EHPA), has been applied to reversed-phase high-performance liquid chromatography (RP-HPLC). The reversed-phase stationary phase was dynamically modified with EHPA by flowing the mobile phase of an acetone-water mixture containing the extracting regent. The retention of lanthanoid elements was widely varied by changing the conditions of the mobile phase, i.e., the pH, the EHPA concentration and the acetone content. The selectivity of EHPA is well reflected to the chromatographic systems, and a precise separation of lanthanoid elements was achieved with sufficient resolution. The determination of Sm was examined in the presence of a large amount of Nd. A linear calibration graph was obtained for Sm at the level of 10 -7 mol dm -3 , in the presence of 1x10 -4 mol dm -3 of Nd. (author)

  20. Simultaneous determination of 18α-glycyrrhetinic acid and 18β-glycyrrhetinic acid in Glycyrrhiza glabra root by reversed phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Ambika Chamoli

    2016-01-01

    Full Text Available Background: The aim of the present research work is to develop a high-performance liquid chromatography (HPLC method for simultaneous analysis of 18α-glycyrrhetinic acid (18α-GA and 18β-GA (18β-GA of Glycyrrhiza glabra. Materials and Methods: About 20 μL aliquots of each 18α-GA and 18β-GA were analyzed using reversed-phase C-18 column. The mobile phase was acetonitrile:tetrahydrofuran:water (10:80:10, v/v/v. The run time was 10 min at flow rate of 1 ml/min. Ultraviolet detection was carried out at 254 nm. Results: 18α-GA and 18β-GA were well resolved in reversed phase C-18 column using mobile phase acetonitrile: tetrahydrofuran: water (10:80:10, v/v/v, pH 7.9. The Rtof 18α-GA and 18β-GA was detected at 2.091 and 2.377 min, respectively. Conclusion: The developed chromatography method could be extended for potential quantification or simultaneous determination of these markers in plant as well as in herbal formulation.

  1. Development of a validated HPLC method for the determination of sennoside A and B, two major constituents of Cassia obovata Coll.

    Directory of Open Access Journals (Sweden)

    Ghassemi-Dehkordi Nasrollah

    2014-04-01

    Full Text Available Introduction: Cassia obovata Coll is the only Senna species which grows wild in Iran. In the present study, an optimised reverse High Performance Liquid Chromatography (HPLC validated method was established for quantification of sennosides A and B, the major constituents of C. obovata with a simple and accurate method. Methods: HPLC analysis was done using Waters 515 pump on a Nova-Pak C18 (3.9 × 150 mm. Millennium software was used for the determination of the sennoside A and B in Cassia species and processing the information. The method was validated according to USP 32 requirements. Results: The solvent impact on the selectivity factor and partition coefficient parameters evaluated. Using a conventional RP-18 L1 column, 3.9 × 150 mm, the mobile phase was selected after several trials with different mixtures of water and acetonitrile. Sennosides A and B were determined using the external standard calibration method. Using USP 35-NF 30, the LOD and LOQ were calculated. The reliability of the HPLC-method for analysis of sennoside A + B was validated through its linearity, reproducibility, repeatability, and recovery. Fina1ly ethanol:water (1:1 extracts of Cassia obovata and Cassia angustifolia were standardized by assay of sennoside A and B through above HPLC validated method. Conclusion: Through the above method, determination of sennosides in Cassia species are completely possible. Moreover, through comparing the results, even though sennosides are rich in Cassia angustifolia but, the results shows that C. obovata could be considered as an alternative source for sennosides A and B.

  2. HPLC ‘Multi-Analyte’ Detection Method

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticides carrying chromophoric structures by HPLC is described. Details are given on the materials and methods used. Recorded UV spectra of active substances are presented for allowing the verification of purity and the confirmation of substances eluting from the HPLC column. (author)

  3. Development and validation of a reversed-phase HPLC method for simultaneous estimation of clotrimazole and beclomethasone dipropionate in lotion and cream dosage form

    Directory of Open Access Journals (Sweden)

    Komal R Dhudashia

    2013-01-01

    Full Text Available Background: The combination of Clotrimazole and Beclomethasone dipropionate is used as anti-fungal and anti-inflammatory for external use in the form of cream and lotion. Aim: A simple, specific, economic, precise, and accurate reversed-phase high performance liquid chromatographic method development for the simultaneous estimation of clotrimazole (CT and beclomethasone dipropionate (BD in lotion and cream formulations. Materials and Methods: The chromatographic separation was achieved on a Kromasil C18 (150 mm × 4.6 mm, 5 μm analytical column. A mixture of acetonitrile-water (70:30, v/v was used as the mobile phase, at a flow rate of 1 ml/min and detector wavelength at 254 nm. The validation of the proposed method was carried out for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation, and system suitability test as per ICH guideline. Results: The retention time of CT and BD was found to be 5.4 and 4 min, respectively. The linear dynamic ranges were from 2-16 μg/ml and 80-640 μg/ml for BD and CT, respectively. Limit of detection and quantification for BD were 0.039 and 0.12 μg/ml, for CT 1.24 and 3.77 μg/ml, respectively. Conclusions: The developed method was validated and found to be simple, specific, accurate and precise and can be used for routine quality control analysis of titled drugs in combination in lotion and cream formulation.

  4. Development and Validation of an HPLC Method for the Analysis of Sirolimus in Drug Products

    Directory of Open Access Journals (Sweden)

    Hadi Valizadeh

    2012-05-01

    Full Text Available Purpose: The aim of this study was to develop a simple, rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC method for quantification of sirolimus (SRL in pharmaceutical dosage forms. Methods: The chromatographic system employs isocratic elution using a Knauer- C18, 5 mm, 4.6 × 150 mm. Mobile phase consisting of acetonitril and ammonium acetate buffer set at flow rate 1.5 ml/min. The analyte was detected and quantified at 278nm using ultraviolet detector. The method was validated as per ICH guidelines. Results: The standard curve was found to have a linear relationship (r2 > 0.99 over the analytical range of 125–2000ng/ml. For all quality control (QC standards in intraday and interday assay, accuracy and precision range were -0.96 to 6.30 and 0.86 to 13.74 respectively, demonstrating the precision and accuracy over the analytical range. Samples were stable during preparation and analysis procedure. Conclusion: Therefore the rapid and sensitive developed method can be used for the routine analysis of sirolimus such as dissolution and stability assays of pre- and post-marketed dosage forms.

  5. An HPLC method for determination of azadirachtin residues in bovine muscle.

    Science.gov (United States)

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  6. Impurity profiling of liothyronine sodium by means of reversed phase HPLC, high resolution mass spectrometry, on-line H/D exchange and UV/Vis absorption.

    Science.gov (United States)

    Ruggenthaler, M; Grass, J; Schuh, W; Huber, C G; Reischl, R J

    2017-09-05

    For the first time, a comprehensive investigation of the impurity profile of the synthetic thyroid API (active pharmaceutical ingredient) liothyronine sodium (LT 3 Na) was performed by using reversed phase HPLC and advanced structural elucidation techniques including high resolution tandem mass spectrometry (HRMS/MS) and on-line hydrogen-deuterium (H/D) exchange. Overall, 39 compounds were characterized and 25 of these related substances were previously unknown to literature. The impurity classification system recently developed for the closely related API levothyroxine sodium (LT 4 Na) could be applied to the newly characterized liothyronine sodium impurities resulting in a wholistic thyroid API impurity classification system. Furthermore, the mass-spectrometric CID-fragmentation of specific related substances was discussed and rationalized by detailed fragmentation pathways. Moreover, the UV/Vis absorption characteristics of the API and selected impurities were investigated to corroborate chemical structure assignments derived from MS data. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method

    Directory of Open Access Journals (Sweden)

    Semahat Kucukkolbasi

    2013-01-01

    Full Text Available In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione in multivitamin tablets. The linearity of the method was excellent (R² > 0.999 over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.

  8. Complete separation of racemic p-boronophenylalanine by high performance liquid chromatography with crown ether-coated reversed-phase packings

    International Nuclear Information System (INIS)

    Yoshino, K.; Mieda, S.; Maruyama, T.; Mori, Y.; Mishima, Y.; Ichihashi, M.

    1992-01-01

    Since the L-form of p-boronophenylalanine (p-bpa) has been shown to be more efficiently incorporated into melanoma cells than racemic p-bpa separation of racemic p-bpa into its stereoisomers is an important subject. One of the preparative methods used to resolve racemic p-bpa involves the use of α-chymotrypsin. However, there has been a problem in that optical purity of resolved L- or D-p-bpa products was not easily determined. In this paper, the authors describe a method which can be used to confirm the optical purity of b-pba using high performance liquid chromatography (HPLC) with crown ether-coated reversed-phase packings

  9. Carotenoids from Foods of Plant, Animal and Marine Origin: An Efficient HPLC-DAD Separation Method

    Directory of Open Access Journals (Sweden)

    Irini F. Strati

    2012-12-01

    Full Text Available Carotenoids are important antioxidant compounds, present in many foods of plant, animal and marine origin. The aim of the present study was to describe the carotenoid composition of tomato waste, prawn muscle and cephalothorax and avian (duck and goose egg yolks through the use of a modified gradient elution HPLC method with a C30 reversed-phase column for the efficient separation and analysis of carotenoids and their cis-isomers. Elution time was reduced from 60 to 45 min without affecting the separation efficiency. All-trans lycopene predominated in tomato waste, followed by all-trans-β-carotene, 13-cis-lutein and all-trans lutein, while minor amounts of 9-cis-lutein, 13-cis-β-carotene and 9-cis-β-carotene were also detected. Considering the above findings, tomato waste is confirmed to be an excellent source of recovering carotenoids, especially all-trans lycopene, for commercial use. Xanthophylls were the major carotenoids of avian egg yolks, all-trans lutein and all-trans zeaxanthin in duck and goose egg yolk, respectively. In the Penaeus kerathurus prawn, several carotenoids (zeaxanthin, all-trans-lutein, canthaxanthin, cryptoxanthin, optical and geometrical astaxanthin isomers were identified in considerable amounts by the same method. A major advantage of this HPLC method was the efficient separation of carotenoids and their cis-isomers, originating from a wide range of matrices.

  10. Comparison of direct injection nebulizer and desolvating microconcentric nebulizer for analysis of chlorine-, bromine- and iodine-containing compounds by reversed phase HPLC with ICP-MS detection

    DEFF Research Database (Denmark)

    Jensen, B.P.; Gammelgaard, Bente; Hansen, S.H.

    2003-01-01

    the direct injection nebulizer at flow rates of 25 and 50 mul min(-1), the influence of 0-50% methanol and 0-25% acetonitrile on the sensitivity was studied. For chlorine and bromine, the relative sensitivity decreased with increasing amounts of organic solvent. For iodine, the relative sensitivity reached...... structure. Many chlorine-, bromine-, and iodine-containing compounds were partially lost in the desolvating unit. For those chlorine- and iodine-containing compounds that were not lost, the sensitivity was independent of methanol concentration in the solvent when a 0-100% methanol gradient was applied......With the purpose of finding ways to combine micro-bore reversed phase HPLC with ICP-MS detection for analysis of drug substances containing chlorine, bromine and iodine, the suitability of a direct injection nebulizer and an Aridus desolvating microconcentric nebulizer was compared. Using...

  11. An HPLC method for the determination of digoxin in dissolution samples

    Directory of Open Access Journals (Sweden)

    Milenković Miroslav Ž.

    2010-01-01

    Full Text Available An HPLC method for digoxin quantification in dissolution samples obtained as per the official British Pharmacopeia (BP method is presented in this paper. The chromatography was performed at 20 °C on a Symmetry C18; 3.5 ìm, 75 x 4.6 mm column with water - acetonitrile (72 : 28, v/v, as the mobile phase and UV detection at 220 nm. The method was found to be selective, linear, accurate and precise in the specified ranges. The LOD and LOQ were 0.015 μg mL-1 and 0.050 μg mL-1, respectively. Robustness testing was conducted to evaluate the impact of minor changes in the chromatographic parameters (i.e., acetonitrile fraction, flow rate of the mobile phase, column temperature and column length on the characteristics of the digoxin peak. A. full factorial design (24 was used to investigate the influence of the four variables The presented HPLC method was applied in quality and stability testing of Digoxin tablets 0.25 mg.

  12. Stability-Indicating RP-HPLC Method for Determination of Guanfacine Hydrochloride in Bulk Drugs and in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    Vinod K. Ahirrao

    2011-04-01

    Full Text Available A novel stability-indicating RP-HPLC method was developed and validated for quantitative determination of guanfacine hydrochloride in bulk drug and in pharmaceutical dosage form. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using Apollo, C18 (250mm x 4.6mm, 5µm column with mobile phase of 50mM Ammonium acetate (volatile buffer and acetonitrile (65:35, v/v. UV detection has been done at wavelength 220 nm. The guanfacine hydrochloride was subjected to the stress conditions of hydrolysis (acid, base, oxidation, photolysis and thermal degradation. The stressed samples were analyzed by the proposed method. The analyte peak shape was excellent. The described method shows excellent linearity over a range of 30 – 450 µg/mL. The correlation coefficient for guanfacine hydrochloride was 0.999. The limit of detection for Guanfacine hydrochloride is 0.011 µg/mL and the limit of quantification is 0.038 µg/mL respectively.Degradation was observed for guanfacine hydrochloride in base, thermal and in 30% H2O2 conditions. The drug was found to be stable in the other stress conditions attempted. The degradation products were well resolved from main peak. The percentage recovery of guanfacine hydrochloride was ranged from (99.2% to 100.5% in pharmaceutical dosage form. The developed method was validated with respect to the linearity, accuracy (recovery, precision, specificity and robustness. The forced degradation studies prove the stability indicating power of the method.

  13. Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    V. Rajesh

    2011-01-01

    Full Text Available A new reverse phase high performance liquid chromatography (RP-HPLC method has been developed for the simultaneous estimation of gemcitabine hydrochloride and capecitabine hydrochloride in combined tablet dosage form. An inertsil ODS-3 C-18 column having dimensions of 250×4.6 mm and particle size of 5 µm, with mobile phase containing a mixture of acetonitrile : water : triethyelamine in the ratio of (70 : 28 : 2v/v was used. The pH of mobile phase was adjusted to 4.0 with ortho-phosphoric acid. The flow rate was 1 mL/min and the column effluents were monitored at 260 nm. The retention time for gemcitabine hydrochloride and capecitabine hydrochloride was found to be 2.76 and 2.3 min respectively. The proposed method was validated in terms of linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The method was found to be linear in the range of 10-50 µg/mL and 4-24 µg/mL for gemcitabine hydrochloride and capecitabine hydrochloride, with regression coefficient r = 0.999 and r = 0.999, respectively.

  14. A validated bioanalytical HPLC method for pharmacokinetic evaluation of 2-deoxyglucose in human plasma.

    Science.gov (United States)

    Gounder, Murugesan K; Lin, Hongxia; Stein, Mark; Goodin, Susan; Bertino, Joseph R; Kong, Ah-Ng Tony; DiPaola, Robert S

    2012-05-01

    2-Deoxyglucose (2-DG), an analog of glucose, is widely used to interfere with glycolysis in tumor cells and studied as a therapeutic approach in clinical trials. To evaluate the pharmacokinetics of 2-DG, we describe the development and validation of a sensitive HPLC fluorescent method for the quantitation of 2-DG in plasma. Plasma samples were deproteinized with methanol and the supernatant was dried at 45°C. The residues were dissolved in methanolic sodium acetate-boric acid solution. 2-DG and other monosaccharides were derivatized to 2-aminobenzoic acid derivatives in a single step in the presence of sodium cyanoborohydride at 80°C for 45 min. The analytes were separated on a YMC ODS C₁₈ reversed-phase column using gradient elution. The excitation and emission wavelengths were set at 360 and 425 nm. The 2-DG calibration curves were linear over the range of 0.63-300 µg/mL with a limit of detection of 0.5 µg/mL. The assay provided satisfactory intra-day and inter-day precision with RSD less than 9.8%, and the accuracy ranged from 86.8 to 110.0%. The HPLC method is reproducible and suitable for the quantitation of 2-DG in plasma. The method was successfully applied to characterize the pharmacokinetics profile of 2-DG in patients with advanced solid tumors. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Dual-mode gradient HPLC procedure for the simultaneous determination of chloroquine and proguanil.

    Science.gov (United States)

    Paci, A; Caire-Maurisier, A-M; Rieutord, A; Brion, F; Clair, P

    2002-01-01

    In order to assay the antipaludic capsule of the Service de Santé des Armées (SSA), that contains two antimalarial drugs, i.e. chloroquine sulfate (CQS, cp1) and proguanil hydrochloride (PGH, cp5), a HPLC procedure was developed. A reversed-phase ion-pair high-performance liquid chromatography (HPLC) method with an ultraviolet detection at 254 nm was set up and validated. Elution system includes programming of both organic concentration and flow-rate known as 'dual-mode gradient'. This method allows the simultaneous determination of both active compounds and separation of four process related substances. The method is simple, rapid, selective and accurate, and the precision is good with an inter- and intra-assay of <2%. The sensitivity is particularly suitable for pharmaceutical quality control.

  16. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  17. Validated RP-HPLC/DAD Method for the Quantification of Insect Repellent Ethyl 2-Aminobenzoate in Membrane-Moderated Matrix Type Monolithic Polymeric Device.

    Science.gov (United States)

    Islam, Johirul; Zaman, Kamaruz; Chakrabarti, Srijita; Sharma Bora, Nilutpal; Mandal, Santa; Pratim Pathak, Manash; Srinivas Raju, Pakalapati; Chattopadhyay, Pronobesh

    2017-07-01

    A simple, accurate and sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the estimation of ethyl 2-aminobenzoate (EAB) in a matrix type monolithic polymeric device and validated as per the International Conference on Harmonization guidelines. The analysis was performed isocratically on a ZORBAX Eclipse plus C18 analytical column (250 × 4.4 mm, 5 μm) and a diode array detector (DAD) using acetonitrile and water (75:25 v/v) as the mobile phase by keeping the flow-rate constant at 1.0 mL/min. Determination of EAB was not interfered in the presence of excipients. Inter- and intra-day relative standard deviations were not higher than 2%. Mean recovery was between 98.7 and 101.3%. Calibration curve was linear in the concentration range of 0.5-10 µg/mL. Limits of detection and quantification were 0.19 and 0.60 µg/mL, respectively. Thus, the present report put forward a novel method for the estimation of EAB, an emerging insect repellent, by using RP-HPLC technique. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Elution behavior of N-heterocyclic derivatives of mixed ruthenium(II)-sulfoxide complexes in reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Toma, H.E.; Silva, D.O.

    1991-01-01

    The elution behaviour of a series of dichlorobis-(dimethylsulfoxide)bis(N-heterocyclic) ruthenium(II) complexes has been investigated using reversed-phase HPLC. Similar trends as those displayed by the free N-heterocyclic bases have been observed for the complexes, essentially reflecting the hydrophobic properties of the aromatic ligands. (orig.)

  19. Determination of free urinary cortisol in cushing's syndrome using reversed-phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Eduardo Kinio Sugawara

    2010-01-01

    Full Text Available Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS. A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v, with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

  20. A general method for the purification of synthetic oligodeoxyribonucleotides containing strong secondary structure by reversed-phase high-performance liquid chromatography on PRP-1 resin.

    Science.gov (United States)

    Germann, M W; Pon, R T; van de Sande, J H

    1987-09-01

    Synthetic 5'-dimethoxytritylated oligodeoxyribonucleotides, which contained strong secondary structure, were satisfactorily denatured and purified by reversed-phase HPLC on PRP-1 columns when strongly alkaline conditions (0.05 M NaOH) were employed. This procedure was suitable for the purification of hairpin structures, e.g., d(CG)nT4(CG)n (n = 4, 5, 6), and oligo(dG) sequences, e.g., d(G)24, as well as oligodeoxyribonucleotide probes which contained degenerate base sites. Oligodeoxyribonucleotides as long as 50 bases in length were purified. Recovery of injected oligonucleotides was typically 90% or better. The high capacity of the PRP-1 resin also allowed purification to be performed on a preparative scale (2-8 mg per injection). Enzymatic degradation and HPLC analysis indicated that no modification of the heterocyclic bases occurred under the alkaline conditions described.

  1. HPTLC and reverse phase HPLC methods for the simultaneous quantification and in vitro screening of antioxidant potential of isolated sesquiterpenoids from the rhizomes of Cyperus rotundus.

    Science.gov (United States)

    Priya Rani, M; Padmakumari, K P

    2012-09-01

    Three sesquiterpenoids solavetivone, aristolone and nootkatone were isolated from the acetone extract of Cyperus rotundus by silica gel column chromatography and identified by spectral studies. Solavetivone has been isolated for the first time from the species. Simple, sensitive and selective HPTLC and HPLC methods with ultraviolet detection (245 nm) were developed and validated for the simultaneous quantification. HPTLC method was validated in terms of their linearity, LOD, LOQ, precision, accuracy and compared with RP-HPLC-UV method. Among the three sesquiterpenoids isolated, nootkatone possessed the highest radical scavenging potential (IC(50) 4.81 μg/ml) followed by aristolone (IC(50) 5.28 μg/ml) and solavetivone (IC(50) 6.82 μg/ml) by DPPH radical scavenging assay. Total antioxidant activity against phosphomolybdenum reagent was also studied. The methods described in this paper were able to identify and quantify sesquiterpenoids from the complex mixtures of phytochemicals and could be extended to the marker based standardization of polyherbal formulations containing C. rotundus. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. High-Performance Liquid Chromatography (HPLC)-Based Detection and Quantitation of Cellular c-di-GMP.

    Science.gov (United States)

    Petrova, Olga E; Sauer, Karin

    2017-01-01

    The modulation of c-di-GMP levels plays a vital role in the regulation of various processes in a wide array of bacterial species. Thus, investigation of c-di-GMP regulation requires reliable methods for the assessment of c-di-GMP levels and turnover. Reversed-phase high-performance liquid chromatography (RP-HPLC) analysis has become a commonly used approach to accomplish these goals. The following describes the extraction and HPLC-based detection and quantification of c-di-GMP from Pseudomonas aeruginosa samples, a procedure that is amenable to modifications for the analysis of c-di-GMP in other bacterial species.

  3. Preparation and characterization of a new microwave immobilized poly(2-phenylpropyl)methylsiloxane stationary phase for reversed phase high-performance liquid chromatography.

    Science.gov (United States)

    Begnini, Fernanda R; Jardim, Isabel C S F

    2013-07-05

    A new reversed phase high-performance liquid chromatography (RP-HPLC) stationary phase was prepared and its chromatographic and physical-chemical properties were evaluated. The new stationary phase was prepared with a silica support and poly(2-phenylpropyl)methylsiloxane (PPPMS), a phenyl type polysiloxane copolymer. Since this is a new copolymer and there is little information in the literature, it was submitted to physical-chemical characterization by infrared spectroscopy and thermogravimetry. The chromatographic phase was prepared through sorption and microwave immobilization of the copolymer onto a silica support. The chromatographic performance was evaluated by employing test procedures suggested by Engelhardt and Jungheim, Tanaka and co-workers, Neue, and Szabó and Csató. These test mixtures provide information about the hydrophobic selectivity, silanophilic activity, ion-exchange capacity, shape selectivity and interaction with polar analytes of the new Si-PPPMS reversed phase. Stability tests were developed using accelerated aging tests under both basic and acidic conditions to provide information about the lifetime of the packed columns. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-01-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 μ, The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105 ° C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70-130 μg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  5. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-07-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 µL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 µ. The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105°C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70–130 µg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  6. Development and Validation of a Stability-Indicating HPLC Method for the Simultaneous Determination of Florfenicol and Flunixin Meglumine Combination in an Injectable Solution

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-01-01

    Full Text Available The combination of the powerful antimicrobial agent florfenicol and the nonsteroidal anti-inflammatory flunixin meglumine is used for the treatment of bovine respiratory disease (BRD and control of BRD-associated pyrexia, in beef and nonlactating dairy cattle. This study describes the development and validation of an HPLC-UV method for the simultaneous determination of florfenicol and flunixin, in an injectable preparation with a mixture of excipients. The proposed RP-HPLC method was developed by a reversed phase- (RP- C18e (250 mm × 4.6 mm, 5 μm column at room temperature, with an isocratic mobile phase of acetonitrile and water mixture, and pH was adjusted to 2.8 using diluted phosphoric acid, a flow rate of 1.0 mL/min, and ultraviolet detection at 268 nm. The stability-indicating method was developed by exposing the drugs to stress conditions of acid and base hydrolysis, oxidation, photodegradation, and thermal degradation; the obtained degraded products were successfully separated from the APIs. This method was validated in accordance with FDA and ICH guidelines and showed excellent linearity, accuracy, precision, specificity, robustness, LOD, LOQ, and system suitability results within the acceptance criteria.

  7. Ultrasound extracted flavonoids from four varieties of Portuguese red grape skins determined by reverse-phase high-performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria

    2008-12-23

    Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.

  8. Development and Validation of a Rapid RP-HPLC Method for the Determination of Venlafaxine Hydrochloride in Pharmaceutical Dosage forms using Experimental Design

    Directory of Open Access Journals (Sweden)

    Vanita Somasekhar

    2009-01-01

    Full Text Available The objective of the current study was to develop a simple, accurate, precise and rapid reversed-phase HPLC method and subsequent validation as per ICH guidelines for the determination of venlafaxine hydrochloride in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a 5 μm Varian® Microsorb-MV 100 C18 column (250 mmx4.6 mm at ambient temperature. A 23 factorial design consisting of 3 factors at 2 levels was set up to standardize the chromatographic conditions. A numerical optimization technique employing the desirability approach was used to locate the optimum chromatographic conditions. The optimum mobile phase consisted of acetonitrile, 0.04 M potassium dihydrogen phosphate buffer and methanol (45:25:30, v/v, with pH adjusted to 5.5 using 10% phosphoric acid solution. The mobile phase was delivered isocratically at a flow rate of 1 mL/min with UV detection at 224 nm. The calibration plots constructed using the optimized chromatographic conditions displayed good linear relationship in the concentration range of 1-50 μg/mL with r=0.9992. The method was validated for precision, accuracy, robustness and recovery. The minimum detectable and minimum quantifiable amounts were found to be 0.568 and 1.72 μg/mL, respectively and the method was found to be reproducible from the statistical data generated. Venlafaxine hydrochloride was eluted at 3.43 min

  9. Investigation of folic acid stability in fortified instant noodles by use of capillary electrophoresis and reversed-phase high performance liquid chromatography.

    Science.gov (United States)

    Hau Fung Cheung, Rodney; Morrison, Paul D; Small, Darryl M; Marriott, Philip J

    2008-12-05

    A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).

  10. Cluster analysis of historical and modern hard red spring wheat cultivars based on parentage and HPLC analysis of gluten forming proteins

    Science.gov (United States)

    In this study, 30 hard red spring (HRS) wheat cultivars released between 1910 and 2013 were analyzed to determine how they cluster in terms of parentage and protein data, analyzed by reverse-phase HPLC (RP-HPLC) of gliadins, and size-exclusion HPLC (SE-HPLC) of unreduced proteins. Dwarfing genes in...

  11. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Quantitative determination for cytotoxic Friedo-nor-oleanane derivatives from five morphological types of Maytenus ilicifolia (Celastraceae) by reverse-phase high-performance liquid chromatography.

    Science.gov (United States)

    Buffa Filho, Waldemar; Corsino, Joaquim; Bolzani, da Silva Vanderlan; Furlan, Maysa; Pereira, Ana Maria S; França, Suzelei Castro

    2002-01-01

    Five different morphological types of Maytenus ilicifolia of the same age and harvested under the same conditions showed distinct accumulations of some friedo-nor-oleananes. A rapid, sensitive and reliable reverse-phase HPLC method (employing an external standard) was used for the determination of the cytotoxic triterpenoids, 20 alpha-hydroxymaytenin, 22 beta-hydroxymaytenin, maytenin, celastrol and pristimerin in each of the five types. Well resolved peaks with good detection response and linearity in the range 1.0-100 micrograms/mL were obtained.

  13. Efficient preparation of incensole and incensole acetate, and quantification of these bioactive diterpenes in Boswellia papyrifera by a RP-DAD-HPLC method.

    Science.gov (United States)

    Paul, Michael; Jauch, Johann

    2012-03-01

    Incensole and incensole acetate, found in incense, are encouraging potent bioactive diterpenic cembrenoids, inhibiting Nuclear Factor-kappaB activation. Furthermore, incensole acetate elicits psycho-activity in mice by activating the TRPV3 channels in the brain. Starting from crude extracts of the incense species Boswellia papyrifera Hochst., a convenient procedure for the efficient large-scale synthesis of incensole and its acetate is presented. Additionally, a reversed-phase, diode-array-detection, high-performance liquid chromatography (RP-DAD-HPLC) method for the quantification of incensole and incensole acetate is reported, indicating that these two compounds are typical biomarkers for B. papyrifera.

  14. Estimation of Rabeprazole Sodium and Itopride Hydrochloride in Tablet Dosage Form Using Reverse Phase High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Shaik Harum Rasheed

    2011-01-01

    Full Text Available A reversed phase high performance liquid chromatography (RP-HPLC method was developed, validated and used for the quantitative determination of rabeprazole sodium (RP and itopride hydrochloride (IH, from its tablet dosage form. Chromatographic separation was performed on a Phenomenex C18 column (250 mm × 4.6 mm, 5 μm, with a mobile phase comprising of a mixture of 50 mM ammonium acetate buffer and methanol (20:80v/v, pH 4.5 adjusted with acetic acid, at a flow rate of 1.3 mL/min with detection at 286 nm. Separation was completed in less than 10 min. As per International Conference on Harmonization (ICH guidelines the method was validated for linearity, accuracy, precision, limit of quantitation and limit of detection. Linearity of RP was found to be in the range of 37.5-375 μg/mL and IH was found to be in the range of 5-50 μg/mL. The correlation coefficients were 0.9997 and 0.9995 for RB and IH respectively. The accuracy of the developed method was found to be 98.6-100.7 for RP and 99.42 -100.81 for IH. The experiment shows the developed method is free from interference of excipients. It indicates the developed RP-HPLC method is simple, linear, precise and accurate and it can be conveniently adopted for the routine quality control analysis of the tablet dosage form.

  15. Reversible, on-demand generation of aqueous two-phase microdroplets

    Science.gov (United States)

    Collier, Charles Patrick; Retterer, Scott Thomas; Boreyko, Jonathan Barton; Mruetusatorn, Prachya

    2017-08-15

    The present invention provides methods of on-demand, reversible generation of aqueous two-phase microdroplets core-shell microbeads, microparticle preparations comprising the core-shell microbeads, and drug delivery formulation comprising the microparticle preparations. Because these aqueous microdroplets have volumes comparable to those of cells, they provide an approach to mimicking the dynamic microcompartmentation of biomaterial that naturally occurs within the cytoplasm of cells. Hence, the present methods generate femtoliter aqueous two-phase droplets within a microfluidic oil channel using gated pressure pulses to generate individual, stationary two-phase microdroplets with a well-defined time zero for carrying out controlled and sequential phase transformations over time. Reversible phase transitions between single-phase, two-phase, and core-shell microbead states are obtained via evaporation-induced dehydration and water rehydration.

  16. PURIFICATION OF Cd-BINDING PROTEIN FROM MAIZE ROOTS BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    何笃修; 罗建沅; 全胜

    1991-01-01

    An efficient procedure of purification of Cd-binding protein in roots of maize has been established. Young seedlings of maize were exposed to a medium containing CdCl2 to induce the production of Cd-binding protein in their roots. The protein was purified after heat treatment by ion-exchange chromatography and reverse-phase HPLC. The resulting protein was identified as a purified product by N-terminal amino acid with the dansyl method. Its molecular weight was 3200 dalton, the cysteine content was 29.5%, about 3 Cd atoms were bound to one molecule of the protein and the Cd : cystine ratio was 1 : 2.3. According to its character, this protein could be a kind of plant metallothionein-like protein.

  17. Determination of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations by HPLC.

    Science.gov (United States)

    Almeida, M M; Alves, J M P; Patto, D C S; Lima, C R R C; Quenca-Guillen, J S; Santoro, M I R M; Kedor-Hackmann, E R M

    2009-12-01

    A rapid HPLC method was developed for the assay of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations. The validated method was applied for quantitative determination of these vitamins in simulated emulsion formulation. Samples were analysed directly on a RP-18 reverse phase column with UV detection at 222 nm. A mixture of methanol and isopropanol (25 : 75 v/v) was used as mobile phase. The retention time of tocopheryl acetate and ascorbyl tetraisopalmitate were 3.0 min and 5.9 min, respectively. Recovery was between 95% and 104%. In addition, the excipients did not interfere in the analysis. The method is simple, reproducible, selective and is suitable for routine analyses of commercial products.

  18. Stability-indicating HPLC determination of pramipexole dihydrochloride in bulk drug and pharmaceutical dosage form

    OpenAIRE

    Panditrao, Vedavati M; Sarkate, Aniket P; Sangshetti, Jaiprakash N; Wakte, Pravin S; Shinde, Devanand B

    2011-01-01

    A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for quantitative determination of pramipexole dihydrochloride in bulk drugs and in pharmaceutical dosage form in the presence of degradation products. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using an Ace5-C18 (250×4.6 mm, 5 µm) advance chromatography column, and 10 mmol L-1 ammonium acetate and acetonitrile (75:25 v/v)...

  19. Development of a validated HPLC method for the determination of sennoside A and B, two major constituents of Cassia obovata Coll.

    OpenAIRE

    Ghassemi-Dehkordi Nasrollah; Ghanadian Mustafa; Arabha Sajjad

    2014-01-01

    Introduction: Cassia obovata Coll is the only Senna species which grows wild in Iran. In the present study, an optimised reverse High Performance Liquid Chromatography (HPLC) validated method was established for quantification of sennosides A and B, the major constituents of C. obovata with a simple and accurate method. Methods: HPLC analysis was done using Waters 515 pump on a Nova-Pak C18 (3.9 × 150 mm). Millennium software was used for the determination of the sennoside A and B in Cassia s...

  20. Development and validation of RP-HPLC and UV-spectrophotometric methods for rapid simultaneous estimation of amlodipine and benazepril in pure and fixed dose combination

    Directory of Open Access Journals (Sweden)

    Abhi Kavathia

    2017-05-01

    Full Text Available High-performance liquid chromatographic (HPLC and UV spectrophotometric methods were developed and validated for the quantitative determination of amlodipine besylate (AM and benazepril hydrochloride (BZ. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD and limit of quantification (LOQ were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Shodex C-18 5e column. The retention time for AM and BZ was 4.43 min and 5.70 min respectively. The UV spectrophotometric determinations were performed at 237 nm and 366 nm for AM and at 237 nm for BZ. Correlation between absorbance of AM at 237 nm and 366 nm was established and based on developed correlation equation estimation of BZ at 237 nm was carried out. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 > 0.999 by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 5%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation.

  1. Validation of an HPLC method for the determination of fleroxacin and its photo-degradation products in pharmaceutical forms.

    Science.gov (United States)

    Djurdjevic, Predrag; Laban, Aleksandra; Jelikic-Stankov, Milena

    2004-01-01

    HPLC determination of fleroxacin in dosage forms was carried out using either reversed-phase column YMC pack ODS-AQ or Supelco LC Hisep shielded hydrophobic phase column, with UV detection at 280 nm. The mobile phase for ODS column consisted of 50:50:0.5 v/v/v and for Hisep column 15:85:0.5 v/v/v acetonitrile-water-triethylamine. The pH of the mobile phase was adjusted to 6.30 for ODS column and to 6.85 for Hisep column, with H3PO4. Linear response was obtained in the concentration range of fleroxacin between 0.01 and 1.30 micrograms/mL. Detection limit was 4.8 ng/mL. Recovery test in the determination of fleroxacin in "Quinodis" tablets (Hoffmann La Roche, nominal mass 400 or 200 mg) was 98-101% for both columns. The effect of the composition and pH of the mobile phase on spectra, retention time and dissociation constants of fleroxacin was discussed. The proposed method could be also used for separation of the photo-degradation products of fleroxacin. Ten degradation products were separated on the ODS-AQ column, thus confirming the suitability of the proposed method for stability study of fleroxacin in pharmaceuticals.

  2. Chromatographic Analysis of a Multicomponent Mixture of B1, B6, B12, Benfotiamine, and Diclofenac; Part I: HPLC and UPLC Methods for the Simultaneous Quantification of These Five Components in Tablets and Capsules.

    Science.gov (United States)

    Fayed, Ahmed Salah; Hegazy, Maha Abdel-Monem; Wahab, Nada Sayed Abdel

    2016-11-01

    New, simple, highly sensitive, precise, and accurate gradient reversed-phase chromatographic methods were developed using HPLC and ultra-HPLC (UPLC) systems for the determination of five components, namely thiamine, pyridoxine, cyanocobalamin, benfotiamine, and diclofenac in tablets and capsules. The methods were compared for their efficiency in the separation and determination of these five compounds using two different C18 columns (250 × 4.6 mm, 5 μm; and 100 × 4.6 mm, 2.6 μm) for HPLC and UPLC, respectively. Chromatographic separation was performed with a mobile phase containing acetonitrile and 0.025 M phosphate buffer (pH 3.5), with a gradient program and a flow rate of 1.5 and 1.0 mL/min for both methods, respectively. The methods were validated according to International Conference on Harmonization guidelines. Linearity was achieved in the range of 5.00 to 150.00 μg/mL for each of the five compounds. Ruggedness and intermediate precision were confirmed by different analysts on different columns on different days. Moreover, the components were subjected to an accelerated stability study under acidic, alkaline, and oxidative stress conditions and no interfering peaks were observed. The five compounds were efficiently separated in <20 min by HPLC, whereas for UPLC, separation was achieved in <8 min, which dramatically decreased the consumption of organic solvents.

  3. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    Science.gov (United States)

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  4. Characterization of fatty acid and triacylglycerol composition in animal fats using silver-ion and non-aqueous reversed-phase high-performance liquid chromatography/mass spectrometry and gas chromatography/flame ionization detection

    Czech Academy of Sciences Publication Activity Database

    Lísa, M.; Netušilová, K.; Franěk, L.; Dvořáková, H.; Vrkoslav, Vladimír; Holčapek, M.

    2011-01-01

    Roč. 1218, č. 42 (2011), s. 7499-7510 ISSN 0021-9673 R&D Projects: GA ČR GA203/09/0139 Institutional research plan: CEZ:AV0Z40550506 Keywords : silver-ion HPLC * non-aqueous reversed-phase HPLC * triacylglycerol Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.531, year: 2011

  5. Reversed phase HPLC analysis of stability and microstructural effects on degradation kinetics of β-carotene encapsulated in freeze-dried maltodextrin-emulsion systems.

    Science.gov (United States)

    Harnkarnsujarit, Nathdanai; Charoenrein, Sanguansri; Roos, Yrjö H

    2012-09-26

    Degradation of dispersed lipophilic compounds in hydrophilic solids depends upon matrix stability and lipid physicochemical properties. This study investigated effects of solid microstructure and size of lipid droplets on the stability of dispersed β-carotene in freeze-dried systems. Emulsions of β-carotene in sunflower oil were dispersed in maltodextrin systems (M040/DE6, M100/DE11, and M250/DE25.5) (8% w/w oil) and prefrozen at various freezing conditions prior to freeze-drying to control nucleation and subsequent pore size and structural collapse of freeze-dried solids. The particle size, physical state, and β-carotene contents of freeze-dried emulsions were measured during storage at various water activity (a(w)) using a laser particle size analyzer, differential scanning calorimeter, and high performance liquid chromatography (HPLC), respectively. The results showed that M040 stabilized emulsions in low temperature freezing exhibited lipid crystallization. Collapse of solids in storage at a(w) which plasticized systems to the rubbery state led to flow and increased the size of oil droplets. Degradation of β-carotene analyzed using a reversed-phase C(30) column followed first-order kinetics. Porosity of solids had a major effect on β-carotene stability; however, the highest stability was found in fully plasticized and collapsed solids.

  6. Analysis of proinsulin and its conversion products by reversed-phase high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Linde, S; Welinder, B S; Nielsen, Jens Høiriis

    1993-01-01

    . Most mammals produce a single insulin, but in rodents two non-allelic insulin genes are expressed. There is an inverse ratio between the two insulins in rats and mice, the reason for this being unknown. It has been suggested that differences in transcription, translation (biosynthesis) and...... PIM (intact proinsulin or its intermediates) has been incompletely determined. Studies of the biosynthesis of proinsulins and their conversion with the purpose of revealing some of these points depend on accessible reversed-phase high-performance liquid chromatographic (RP-HPLC) analyses capable...

  7. A Modified Method for Determination of Lumefantrine in Human Plasma by HPLC-UV and Combination of Protein Precipitation and Solid-Phase Extraction: Application to a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Liusheng Huang

    2010-03-01

    Full Text Available An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid followed by solid-phase extraction with Hypersep C8 cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 × 150 mm, 3.5 μm with water/methanol (0.1% TFA as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at λ = 335 nm. The method showed to be linear over a range of 50–10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether—lumefantrine and antiretroviral therapy.

  8. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    Science.gov (United States)

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    Science.gov (United States)

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.

  10. Utilization of Photochemically Induced Fluorescence Detection for HPLC Determination of Genotoxic Impurities in the Vortioxetine Manufacturing Process.

    Science.gov (United States)

    Douša, Michal; Doubský, Jan; Srbek, Jan

    2016-07-01

    An analytical reversed-phase high-performance liquid chromatography (HPLC) method for the detection and quantitative determination of two genotoxic impurities at ppm level present in the vortioxetine manufacturing process is described. Applying the concept of threshold of toxicological concern, a limit of 75 ppm each for both genotoxic impurities was calculated based on the maximum daily dose of active pharmaceutical ingredients. The novel reversed-phase HPLC method with photochemically induced fluorescence detection was developed on XSELECT Charged Surface Hybrid Phenyl-Hexyl column using the mobile phase consisted a mixture of 10 mM ammonium formate pH 3.0 and acetonitrile. The elution was performed using an isocratic composition of 48:52 (v/v) at a flow rate of 1.0 mL/min. The photochemically induced fluorescence detection is based on the use of UV irradiation at 254 nm through measuring the fluorescence intensity at 300 nm and an excitation wavelength of 272 nm to produce fluorescent derivatives of both genotoxic impurities. The online photochemical conversion and detection is easily accomplished for two expected genotoxic impurities and provides a sufficiently low limit detection and quantification for the target analysis. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. [Determination method of polysorbates in powdered soup by HPLC].

    Science.gov (United States)

    Takeda, Y; Abe, Y; Ishiwata, H; Yamada, T

    2001-04-01

    A method for qualitative and quantitative analyses of polysorbates in powdered soup by HPLC was studied. Polysorbates in samples were extracted with acetonitrile after rinsing with n-hexane to remove fats and oils. The extract was cleaned up using a Bond Elut silica gel cartridge (500 mg). The cartridge was washed with ethyl acetate and polysorbates were eluted with a small amount of acetonitrile-methanol (1:2) mixture. The eluate was treated with cobalt thiocyanate solution to form a blue complex with polysorbate. In order to determine polysorbate, the complex was subjected to HPLC with a GPC column, using a mixture of acetonitrile-water (95:5) as a mobile phase, with a detection wavelength of 620 nm. The recoveries of polysorbate 80 added to powdered soups were more than 75% and the determination limit was 0.04 mg/g. When the proposed method was applied to the determination of polysorbates in 16 commercial samples of powdered soup for instant noodles and seasoning consomme, no polysorbates were detected in any sample.

  12. Use of HPLC with flow-through radiometric detection for low level environmental analysis

    International Nuclear Information System (INIS)

    Mao, J.; Fackler, P.H.

    1992-01-01

    High Performance Liquid Chromatography with flow-through radiometric detection (HPLC-RAM) is increasingly becoming a standard analytical technique in pharmaceutical, agricultural and chemical industries for monitoring radiolabeled analytes. This paper focuses on the applications of this flow-through radiochromatographic technique for low level aquatic toxicology and environmental fate testing. Examples include parts per billion water, sediment/soil and fish tissue analyses using reverse phase as well as normal phase HPLC. The applications of both homogeneous (liquid) and heterogeneous (solid) flow cell scintillation counting are addressed. Compounds discussed are primarily pesticides and pharmaceuticals

  13. A convenient method for the quantitative determination of elemental sulfur in coal by HPLC analysis of perchloroethylene extracts

    Science.gov (United States)

    Buchanan, D.H.; Coombs, K.J.; Murphy, P.M.; Chaven, C.

    1993-01-01

    A convenient method for the quantitative determination of elemental sulfur in coal is described. Elemental sulfur is extracted from the coal with hot perchloroethylene (PCE) (tetrachloroethene, C2Cl4) and quantitatively determined by HPLC analysis on a C18 reverse-phase column using UV detection. Calibration solutions were prepared from sublimed sulfur. Results of quantitative HPLC analyses agreed with those of a chemical/spectroscopic analysis. The HPLC method was found to be linear over the concentration range of 6 ?? 10-4 to 2 ?? 10-2 g/L. The lower detection limit was 4 ?? 10-4 g/L, which for a coal sample of 20 g is equivalent to 0.0006% by weight of coal. Since elemental sulfur is known to react slowly with hydrocarbons at the temperature of boiling PCE, standard solutions of sulfur in PCE were heated with coals from the Argonne Premium Coal Sample program. Pseudo-first-order uptake of sulfur by the coals was observed over several weeks of heating. For the Illinois No. 6 premium coal, the rate constant for sulfur uptake was 9.7 ?? 10-7 s-1, too small for retrograde reactions between solubilized sulfur and coal to cause a significant loss in elemental sulfur isolated during the analytical extraction. No elemental sulfur was produced when the following pure compounds were heated to reflux in PCE for up to 1 week: benzyl sulfide, octyl sulfide, thiane, thiophene, benzothiophene, dibenzothiophene, sulfuric acid, or ferrous sulfate. A sluury of mineral pyrite in PCE contained elemental sulfur which increased in concentration with heating time. ?? 1993 American Chemical Society.

  14. Simultaneous quantification of flavonoids and triterpenoids in licorice using HPLC.

    Science.gov (United States)

    Wang, Yuan-Chuen; Yang, Yi-Shan

    2007-05-01

    Numerous bioactive compounds are present in licorice (Glycyrrhizae Radix), including flavonoids and triterpenoids. In this study, a reversed-phase high-performance liquid chromatography (HPLC) method for simultaneous quantification of three flavonoids (liquiritin, liquiritigenin and isoliquiritigenin) and four triterpenoids (glycyrrhizin, 18alpha-glycyrrhetinic acid, 18beta-glycyrrhetinic acid and 18beta-glycyrrhetinic acid methyl ester) from licorice was developed, and further, to quantify these 7 compounds from 20 different licorice samples. Specifically, the reverse-phase HPLC was performed with a gradient mobile phase composed of 25 mM phosphate buffer (pH 2.5)-acetonitrile featuring gradient elution steps as follows: 0 min, 100:0; 10 min, 80:20; 50 min, 70:30; 73 min, 50:50; 110 min, 50:50; 125 min, 20:80; 140 min, 20:80, and peaks were detected at 254 nm. By using our technique, a rather good specificity was obtained regarding to the separation of these seven compounds. The regression coefficient for the linear equations for the seven compounds lay between 0.9978 and 0.9992. The limits of detection and quantification lay in the range of 0.044-0.084 and 0.13-0.25 microg/ml, respectively. The relative recovery rates for the seven compounds lay between 96.63+/-2.43 and 103.55+/-2.77%. Coefficient variation for intra-day and inter-day precisions lay in the range of 0.20-1.84 and 0.28-1.86%, respectively. Based upon our validation results, this analytical technique is a convenient method to simultaneous quantify numerous bioactive compounds derived from licorice, featuring good quantification parameters, accuracy and precision.

  15. Determination of amphotericin B in PLA-PEG blend nanoparticles by HPLC-PDA

    Directory of Open Access Journals (Sweden)

    Caroline Danziato Rodrigues

    2014-12-01

    Full Text Available In this work, we developed and validated an effective reversed-phase HPLC method with photodiode array (PDA detection for the quantitative analysis of amphotericin B (AmB in poly(lactide-poly(ethylene glycol (PLA-PEG blend nanoparticles. Chromatographic runs were performed on a reverse phase C18 column using a mobile phase comprising a 9% acetic acid and acetonitrile mixture (40:60, v/v under isocratic elution with a flow rate of 1 mL/min. AmB was detected at a wavelength of 408 nm. The validation process was performed considering the selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD and limit of quantitation (LOQ of the method. A concentration range of 1-20 µg/mL was used to construct a linear calibration curve. The LOQ and LOD were 55 and 18 ng/mL, respectively. The mean recovery of AmB from the samples was 99.92% (relative standard deviation (RSD = 0.34%, n=9, and the method was robust for changes in the flow rate of the mobile phase (maximum RSD=4.82%. The intra- and inter-assay coefficients of variation were less than 0.59%. The method was successfully used to determine the entrapment efficiency of AmB in PLA-PEG blend nanoparticles.

  16. RP-HPLC-DAD method for the determination of phenylepherine, paracetamol, caffeine and chlorpheniramine in bulk and marketed formulation

    Directory of Open Access Journals (Sweden)

    A.P. Dewani

    2014-11-01

    Full Text Available A simple, specific and accurate isocratic RP-HPLC-DAD method was developed for the simultaneous determination of phenylephrine, paracetamol, caffeine and chlorpheniramine in bulk and tablet dosage form. The four contents are present in variable concentrations and have variable chromatographic behavior making the process of analysis very difficult. For present studies a reversed-phase C-18 column (150 mm × 4.5 mm i.d., particle size 5 μm with mobile phase consisting of acetonitrile, methanol and 10 Mm phosphate buffer 16:22:62 (v/v (pH of buffer 2.5 ± 0.02, adjusted with ortho phosphoric acid was used. The flow rate was 1.0 ml/min and eluents were monitored at 280 nm. The mean retention times of phenylephrine, paracetamol, caffeine and chlorpheniramine were found to be 1.8, 3.1, 5.2 and 10.9 min, respectively. The method was validated in terms of linearity, range, specificity, accuracy, precision and robustness. The proposed method was successfully applied to the estimation of phenylephrine, paracetamol, caffeine and chlorpheniramine in combined tablet dosage form.

  17. Effect of the mobile phase on the RP-HPLC analysis of 99mTc-ECD

    International Nuclear Information System (INIS)

    Almeida, Erika V.; Monteiro, Elisiane G.; Mengatti, Jair; Fukumori, Neuza T.O.; Silva, Constancia P.G. da; Matsuda, Margareth M.N.

    2009-01-01

    Technetium-99m labeled L,L-ethylene cysteine dimer ( 99m Tc-ECD) is a neutral, lipophilic complex and brain perfusion imaging agent. The aim of this study was to investigate the effect of the mobile phase on the reversed phase high performance liquid chromatography (RP-HPLC) analysis of 99m Tc-ECD. The HPLC system was LC20AT Prominence model and a Shim-Pack VP-ODS column (250 x 4.6 mm i.d., 5 μm). 99m Tc-ECD was prepared by adding 1 mL of 0.9% NaCl, 1 mL of phosphate buffer (pH 7.5) and 1 mL of Na 99m TcO 4 . The radioactive concentration was 55.5 MBq mL -1 . 20 μL sample volume was injected and 1.0 mL min -1 flow rate was applied. A linear gradient was performed separately with a mixture of ethanol with three different solvents: 12.5 mmol L -1 phosphate buffer (pH 2.5) (solvent A), 0.2 % PIC A (w/v) (pH 6.0) (solvent B) and 0.2 % PIC B5 (w/v) (pH 4.0) (solvent C). 99m Tc-ECD retention times for the mixture of ethanol with solvent A, B and C were 17.38, 17.65 and 17.60 minutes, respectively. These results suggested that the ion pairing reagents (PIC A and PIC B5) did not influence the 99m Tc-ECD analysis, but affected the retention time of impurities as 99m Tc-EC (ethylene dicysteine) and 99m TcO 4 -. 99m Tc-ECD radiochemical purity determined by RP-HPLC was higher than 96% for the mixture of ethanol with the three solvents. The results indicated that the retention time of 99m Tc-ECD was not influenced by the nature of the mobile phase. (author)

  18. [[Chiral separation of five arylpropionic acid drugs and determination of their enantiomers in pharmaceutical preparations by reversed-phase high performance liquid chromatography with cellulose-tris-(4-methylbenzoate) stationary phase

    Science.gov (United States)

    Luo, An; Wan, Qiang; Fan, Huajun; Chen, Zhi; Wu, Xuehao; Huang, Xiaowen; Zang, Linquan

    2014-09-01

    Chromatographic behaviors for enantiomeric separation of arylpropionic acid drugs were systematically developed by reversed phase-high performance liquid chromatography (RP-HPLC) using cellulose-tris-(4-methylbenzoate) (CTMB) as chiral stationary phase (CSP). The effects of the composition of the mobile phase, additives and temperature on chiral separation of flurbiprofen, pranoprofen, naproxen, ibuprofen and loxoprofen were further investigated. The enantiomers had been successfully separated on CSP of CTMB by the mobile phase of methanol-0.1% (v/v) formic acid except naproxen by acetonitrile-0.1% (v/v) formic acid at 25 °C. The mechanisms of the racemic resolution for the above mentioned five drugs are discussed thermodynamically and structurally. The resolutions between respective enantiomers for arylpropionic acid drugs on CTMB had significant differences due to their chromatographic behaviors. The order of resolutions ranked pranoprofen, loxoprofen, flurbiprofen, ibuprofen and naproxen. The method established has been successfully applied to the determination of the enantiomers of the five drugs in commercial preparations under the optimized conditions. It proved that the method is simple, reliable and accurate.

  19. A new method for high yield purification of type beta transforming growth factor from human platelets

    NARCIS (Netherlands)

    Eijnden-van Raaij, A.J.M. van den; Koornneef, I.; Zoelen, E.J.J. van

    1988-01-01

    A new method was developed for the purification of type beta transforming growth factor from human platelets. This method is a three-step procedure including gel filtration, weak cation exchange HPLC and reverse phase HPLC. All steps are carried out at low pH using exclusively volatile acidic buffer

  20. Characterization of Jamaican agro-industrial wastes. Part II, fatty acid profiling using HPLC: precolumn derivatization with phenacyl bromide.

    Science.gov (United States)

    Bailey-Shaw, Y A; Golden, K D; Pearson, A G M; Porter, R B R

    2012-09-01

    This paper describes the determination of fatty acid composition of coffee, citrus and rum distillery wastes using reversed-phase high-performance liquid chromatography (RP-HPLC). Lipid extracts of the waste samples are derivatized with phenacyl bromide and their phenacyl esters are separated on a C8 reversed-phase column by using continuous gradient elution with water and acetonitrile. The presence of saturated and unsaturated fatty acids in quantifiable amounts in the examined wastes, as well as the high percentage recoveries, are clear indications that these wastes have potential value as inexpensive sources of lipids. The HPLC procedures described here could be adopted for further analysis of materials of this nature.

  1. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph

    Directory of Open Access Journals (Sweden)

    Emad M. Hussien

    2014-12-01

    Full Text Available This paper is a continuation to our previous work aiming at development and validation of a reversed-phase HPLC for modernization of tetracycline-related USP monographs and the USP general chapter . Previous results showed that the method is accurate and precise for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline impurity in the drug substance and oral suspension monographs. The aim of the current paper is to examine the feasibility of the method for modernization of USP tetracycline hydrochloride capsule monograph. Specificity, linearity, accuracy and precision were examined for tetracycline hydrochloride assay and 4-epianhydrotetracycline limit. The method was linear in the concentration range from 80% to 160% (r>0.9998 of the assay concentration (0.1 mg/mL for tetracycline hydrochloride and from 50% to 150% (r>0.997 of the acceptance criteria specified in tetracycline hydrochloride capsule monograph for 4-epianhydrotetracycline (NMT 3.0%. The recovery at three concentration levels for tetracycline hydrochloride assay was between 99% and 101% and the RSD from six preparations at the concentration 0.1 mg/mL is less than 0.6%. The recovery for 4-epianhydrotetracycline limit procedure over the concentration range from 50% to 150% is between 96% and 102% with RSD less than 5%. The results met the specified acceptance criteria.

  2. Enantioseparation of dansyl amino acids by HPLC on a monolithic column dynamically coated with a vancomycin derivative.

    Science.gov (United States)

    Pittler, Elfriede; Schmid, Martin G

    2010-11-01

    In this work a chiral stationary phase was prepared by dynamically coating a monolithic reversed-phase HPLC column with a vancomycin-derivative as chiral selector. A hydrophobic alkyl-chain was attached to the vancomycin molecule, providing the immobilization of the chiral selector on the reversed-phase material. Dansyl amino acids were chosen as model analytes for testing the separation power of the dynamically coated phase. All investigated compounds were separated into their enantiomers. Compared with a conventionally packed vancomycin-CSP, a reversal of the enantiomer elution order was obtained. Copyright © 2010 John Wiley & Sons, Ltd.

  3. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  4. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Aschi, Massimiliano; D'Archivio, Angelo Antonio; Maggi, Maria Anna; Mazzeo, Pietro; Ruggieri, Fabrizio

    2007-01-01

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability

  5. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Aschi, Massimiliano [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)]. E-mail: darchivi@univaq.it; Maggi, Maria Anna [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Mazzeo, Pietro [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2007-01-23

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability.

  6. Determination of vitamin E acid succinate in biodegradable microspheres by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Martínez Sancho, C; Herrero Vanrell, R; Negro, S

    2004-01-01

    A simple, rapid, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method is applied to the routine assay of vitamin E acid succinate in biodegradable microspheres. Vitamin E acid-succinate-containing poly-(D,L-lactic-co-glycolic acid) microspheres are prepared by the solvent evaporation method. The starting drug-polymer ratio is 1:10 (w/w) and the total amount of drug and polymer processed is always 440 mg. The content of vitamin E acid succinate in the microspheres is evaluated by HPLC. Chromatography is carried out isocratically at 25 degrees C +/- 0.5 degrees C on an Extrasil ODS-2 column with a mobile phase composed of methanol-water (97:3, v/v) (pH 5.6) at a flow rate of 2 mL/min and UV detection at 284 nm. Parameters such as linearity, limits of quantitation (LOQ) and detection (LOD), precision, accuracy, recovery, specificity, and ruggedness are studied as reported in the International Conference on Harmonization guidelines. The stability of vitamin E acid succinate is also studied with satisfactory results after 48 h at 25 degrees C. The method is selective and linear for drug concentrations in the range 15-210 micro g/mL. The LOQ and LOD are 15 and 3 micro g/mL, respectively. The results for accuracy studies are good. Values for coefficient of variation for intra- and interassay are 2.08% and 2.32%, respectively. The mean percentage of vitamin E acid succinate in the recovery studies is 99.52% +/- 0.81%. The mean loading efficiency for microspheres is 96.53% +/- 1.31%.

  7. Analysis of glutathione in supernatants and lysates of a human proximal tubular cell line from perfusion culture upon intoxication with cadmium chloride by HPLC and LC-ESI-MS

    NARCIS (Netherlands)

    Hahn, Hans; Huck, Christian W; Rainer, Matthias; Najam-ul-Haq, Muhammad; Bakry, Rania; Abberger, Thomas; Jennings, Paul; Pfaller, Walter; Bonn, Günther K

    A simple and highly effective reversed-phase (RP) high-performance liquid chromatography (HPLC) method is described for analysing glutathione (GSH) and glutathione disulfide (GSSG) in out-flowing supernatants and lysates of perfusion cell cultures of human kidney cells (HK-2 cells) continuously

  8. Authentication and Quantitation of Fraud in Extra Virgin Olive Oils Based on HPLC-UV Fingerprinting and Multivariate Calibration

    Science.gov (United States)

    Carranco, Núria; Farrés-Cebrián, Mireia; Saurina, Javier

    2018-01-01

    High performance liquid chromatography method with ultra-violet detection (HPLC-UV) fingerprinting was applied for the analysis and characterization of olive oils, and was performed using a Zorbax Eclipse XDB-C8 reversed-phase column under gradient elution, employing 0.1% formic acid aqueous solution and methanol as mobile phase. More than 130 edible oils, including monovarietal extra-virgin olive oils (EVOOs) and other vegetable oils, were analyzed. Principal component analysis results showed a noticeable discrimination between olive oils and other vegetable oils using raw HPLC-UV chromatographic profiles as data descriptors. However, selected HPLC-UV chromatographic time-window segments were necessary to achieve discrimination among monovarietal EVOOs. Partial least square (PLS) regression was employed to tackle olive oil authentication of Arbequina EVOO adulterated with Picual EVOO, a refined olive oil, and sunflower oil. Highly satisfactory results were obtained after PLS analysis, with overall errors in the quantitation of adulteration in the Arbequina EVOO (minimum 2.5% adulterant) below 2.9%. PMID:29561820

  9. Potency determination of follitropin, lutropin And thyrotropin: a comparison between the quantification by reversed-phase high-performance liquid chromatography and in vivo bioassay

    International Nuclear Information System (INIS)

    Almeida, Beatriz Elane de

    2013-01-01

    With the intention of setting up physico-chemical methods as an alternative to in vivo bioassay for determining biological activity, the hFSH, hTSH and hLH content of native and recombinant preparations was determined by reversed-phase high-performance liquid chromatography (RP-HPLC) and compared with the data obtained by the classical mouse or rat in vivo bioassays (BA). A linear relationship between the two methods was found for these hormones: hFSH BA U= 0.9925 RP-HPLC U– 1.3165, r = 0.9371, p IU = 0.8771 RP-HPLC IU + 12.41, r = 0.9786, p < 0.01, n = 5. For nine other hFSH and eleven hTSH preparations, the mean difference ( ) between the bioactivity predicted from RP-HPLC data via these equations and the mean of the bioactivities obtained with the two methods was as follows. For hLH this difference could not be estimated due to lack of different samples. In the case of hFSH, ± SD = -2.11 ± 3.49% with a precision of 1.16% and in the case of hTSH, ± SD = -2.01 ± 5.56 %, with precision of 1.68%. Partly-degraded hFSH, hTSH and hLH samples presented different activity degrees that could be predicted by RP-HPLC, with an acceptable agreement with the in vivo bioassays. These results demonstrate that the employment of a non-animal physico-chemical assay, such as RP-HPLC, is a viable alternative to the use of an in vivo bioassay for hFSH and hTSH potency determination, thus reducing the number of animals currently used for assuring quality and efficacy of a pharmaceutical product. (author)

  10. Determination of Efavirenz in Human Dried Blood Spots by Reversed-Phase High Performance Liquid Chromatography with UV Detection

    Science.gov (United States)

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-01-01

    Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446

  11. A validated HPLC-PDA method for identification and quantification of two bioactive alkaloids, ephedrine and cryptolepine, in different Sida species.

    Science.gov (United States)

    Chatterjee, Arnab; Kumar, Satyanshu; Chattopadhyay, Sunil K

    2013-12-01

    A simple, rapid, accurate and reproducible reverse-phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP-18 X-terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10-250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra-day and inter-day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Characterization of retentivity of reversed phase liquid chromatography columns.

    Science.gov (United States)

    Ying, P T; Dorsey, J G

    1991-03-01

    There are dozens of commercially available reversed phase columns, most marketed as C-8 or C-18 materials, but with no useful way of classifying their retentivity. A useful way of ranking these columns in terms of column "strength" or retentivity is presented. The method utilizes a value for ln k'(w), the estimated retention of a solute from a mobile phase of 100% water, and the slope of the plot of ln k' vsE(T)(30), the solvent polarity. The method is validated with 26 solutes varying in ln k'(w) from about 2 to over 20, on 14 different reversed phase columns. In agreement with previous work, it is found that the phase volume ratio of the column is the most important parameter in determining retentivity. It is strongly suggested that manufacturers adopt a uniform method of calculating this value and that it be made available in advertising, rather than the uninterpretable "% carbon".

  13. Optimization and validation of a reversed-phase high performance liquid chromatography method for the measurement of bovine liver methylmalonyl-coenzyme a mutase activity.

    Science.gov (United States)

    Ouattara, Bazoumana; Duplessis, Mélissa; Girard, Christiane L

    2013-10-16

    Methylmalonyl-CoA mutase (MCM) is an adenosylcobalamin-dependent enzyme that catalyses the interconversion of (2R)-methylmalonyl-CoA to succinyl-CoA. In humans, a deficit in activity of MCM, due to an impairment of intracellular formation of adenosylcobalamin and methylcobalamin results in a wide spectrum of clinical manifestations ranging from moderate to fatal. Consequently, MCM is the subject of abundant literature. However, there is a lack of consensus on the reliable method to monitor its activity. This metabolic pathway is highly solicited in ruminants because it is essential for the utilization of propionate formed during ruminal fermentation. In lactating dairy cows, propionate is the major substrate for glucose formation. In present study, a reversed-phase high performance liquid chromatography (RP-HPLC) was optimized and validated to evaluate MCM activity in bovine liver. The major aim of the study was to describe the conditions to optimize reproducibility of the method and to determine stability of the enzyme and its product during storage and processing of samples. Specificity of the method was good, as there was no interfering peak from liver extract at the retention times corresponding to methylmalonyl-CoA or succinyl-CoA. Repeatability of the method was improved as compared to previous RP-HPLC published data. Using 66 μg of protein, intra-assay coefficient of variation (CV) of specific activities, ranged from 0.90 to 8.05% and the CV inter-day was 7.40%. Storage and processing conditions (frozen homogenate of fresh tissue vs. fresh homogenate of tissue snapped in liquid nitrogen) did not alter the enzyme activity. The analyte was also stable in liver crude extract for three frozen/thawed cycles when stored at -20°C and thawed to room temperature. The improved method provides a way for studying the effects of stages of lactation, diet composition, and physiology in cattle on MCM activity over long periods of time, such as a complete lactation period

  14. Development of a new extraction technique and HPLC method for the analysis of non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp).

    Science.gov (United States)

    Brighenti, Virginia; Pellati, Federica; Steinbach, Marleen; Maran, Davide; Benvenuti, Stefania

    2017-09-05

    The present work was aimed at the development and validation of a new, efficient and reliable technique for the analysis of the main non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp) inflorescences belonging to different varieties. This study was designed to identify samples with a high content of bioactive compounds, with a view to underscoring the importance of quality control in derived products as well. Different extraction methods, including dynamic maceration (DM), ultrasound-assisted extraction (UAE), microwave-assisted extraction (MAE) and supercritical-fluid extraction (SFE) were applied and compared in order to obtain a high yield of the target analytes from hemp. Dynamic maceration for 45min with ethanol (EtOH) at room temperature proved to be the most suitable technique for the extraction of cannabinoids in hemp samples. The analysis of the target analytes in hemp extracts was carried out by developing a new reversed-phase high-performance liquid chromatography (HPLC) method coupled with diode array (UV/DAD) and electrospray ionization-mass spectrometry (ESI-MS) detection, by using an ion trap mass analyser. An Ascentis Express C 18 column (150mm×3.0mm I.D., 2.7μm) was selected for the HPLC analysis, with a mobile phase composed of 0.1% formic acid in both water and acetonitrile, under gradient elution. The application of the fused-core technology allowed us to obtain a significant improvement of the HPLC performance compared with that of conventional particulate stationary phases, with a shorter analysis time and a remarkable reduction of solvent usage. The analytical method optimized in this study was fully validated to show compliance with international requirements. Furthermore, it was applied to the characterization of nine hemp samples and six hemp-based pharmaceutical products. As such, it was demonstrated to be a very useful tool for the analysis of cannabinoids in both the plant material and its derivatives for

  15. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Erah

    Methods: Reverse phase (RP) chromatographic separation and estimation was achieved ... Recently, the use of natural products in ... one of the major consequences of herb-drug ... assurance and routine analysis of the blend. .... The robustness of the method was evaluated .... compliance with regulatory requirements) of.

  16. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    Energy Technology Data Exchange (ETDEWEB)

    Peter W. Carr; K.M. Fuller; D.R. Stoll; L.D. Steinkraus; M.S. Pasha; Glenn G. Hardin

    2005-12-30

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.

  17. HPLC purification and re-evaluation of chemical identity of two circular bacteriocins, gassericin A and reutericin 6.

    Science.gov (United States)

    Arakawa, K; Kawai, Y; Ito, Y; Nakamura, K; Chujo, T; Nishimura, J; Kitazawa, H; Saito, T

    2010-04-01

    The study aimed for the complete purification and recharacterization of the highly hydrophobic circular bacteriocins, gassericin A and reutericin 6. Gassericin A and reutericin 6 were purified to homogeneity using previously described method and reverse-phase HPLC with an octyl column and eluents of aqueous acetonitrile and 2-propanol. Mass analysis, N-terminal sequencing and bacteriocin assay of the HPLC-purified bacteriocins showed the two bacteriocins had identical seamless circular structures with the same m/z value (5651) of [M + H](+) and both had the same specific activity. D/L-amino acid composition analysis using two distinct methods with the chiral fluorescent derivatization reagents (+)-1-(9-fluorenyl)ethyl chloroformate and O-phthalaldehyde/N-acetyl-L-cystein revealed neither gassericin A nor reutericin 6 contained D-alanine residues contrary to our previous results. Purified gassericin A and reutericin 6 are chemically identical circular molecules containing no D-alanine residues. The HPLC conditions developed in this study will facilitate advanced purification and correct characterization of other highly hydrophobic bacteriocins.

  18. An Isocratic Toxic Chemical-Free Mobile Phase HPLC-PDA Analysis of Malachite Green and Leuco-Malachite Green

    OpenAIRE

    Furusawa, Naoto

    2014-01-01

    This paper describes a reserved-phase high-performance liquid chromatographic (HPLC) method for detecting malachite green (MG) and leuco-malachite green (LMG) using an isocratic toxic organic solvent/reagent-free mobile phase. Chromatographic separations were performed an Inertsil® WP300 C4 with 0.02 mol/L octane sulfonic acid–ethanol mobile phase and a photodiode-array detector. The total run time was <5 min. The system suitability was well within the international acceptance criteria. A...

  19. LC-H-1 NMR used for determination of the elution order of S-naproxen glucuronide isomers in two isocratic reversed-phase LC-systems

    DEFF Research Database (Denmark)

    Mortensen, R. W.; Corcoran, O.; Cornett, Claus

    2001-01-01

    . In both systems the elution order for the 2-, 3- and 4-O-acyl isomers corresponded with previously published results for 2-, 3-, and 4-fluorobenzoic acid glucuronide isomers determined by reversed phase HPLC-H-1 NMR [U.G. Sidelmann, S.H. Hansen, C. Gavaghan, A.W. Nicholls, H.A.J. Carless, J.C. Lindon, I...

  20. An Isocratic Toxic Chemical-Free Mobile Phase HPLC-PDA Analysis of Malachite Green and Leuco-Malachite Green

    Directory of Open Access Journals (Sweden)

    Naoto Furusawa

    2014-05-01

    Full Text Available This paper describes a reserved-phase high-performance liquid chromatographic (HPLC method for detecting malachite green (MG and leuco-malachite green (LMG using an isocratic toxic organic solvent/reagent-free mobile phase. Chromatographic separations were performed an Inertsil® WP300 C4 with 0.02 mol/L octane sulfonic acid–ethanol mobile phase and a photodiode-array detector. The total run time was <5 min. The system suitability was well within the international acceptance criteria. A harmless method for simultaneously detecting MG and LMG was developed and may be further applied to the quantification in foods.

  1. HPLC/Fluorometric Detection of Carvedilol in Real Human Plasma Samples Using Liquid-Liquid Extraction.

    Science.gov (United States)

    Yilmaz, Bilal; Arslan, Sakir

    2016-03-01

    A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed to quantify carvedilol in human plasma using an isocratic system with fluorescence detection. The method included a single-step liquid-liquid extraction with diethylether and ethylacetate mixture (3 : 1, v/v). HPLC separation was carried out by reversed-phase chromatography with a mobile phase composed of 20 mM phosphate buffer (pH 7)-acetonitrile (65 : 35, v/v), pumped at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 240 nm (excitation) and 330 nm (emission). The calibration curve for carvedilol was linear from 10 to 250 ng/mL. Intra- and interday precision values for carvedilol in human plasma were plasma averaged out to 91.8%. The limits of detection and quantification of carvedilol were 3.0 and 10 ng/mL, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 25 mg carvedilol. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  3. Development and Validation of HPLC Method for the Simultaneous Determination of Five Food Additives and Caffeine in Soft Drinks

    Directory of Open Access Journals (Sweden)

    Bürge Aşçı

    2016-01-01

    Full Text Available Box-Behnken design was applied to optimize high performance liquid chromatography (HPLC conditions for the simultaneous determination of potassium sorbate, sodium benzoate, carmoisine, allura red, ponceau 4R, and caffeine in commercial soft drinks. The experimental variables chosen were pH (6.0–7.0, flow rate (1.0–1.4 mL/min, and mobile phase ratio (85–95% acetate buffer. Resolution values of all peak pairs were used as a response. Stationary phase was Inertsil OctaDecylSilane- (ODS- 3V reverse phase column (250 × 4.6 mm, 5 μm dimensions. The detection was performed at 230 nm. Optimal values were found 6.0 pH, 1.0 mL/min flow rate, and 95% mobile phase ratio for the method which was validated by calculating the linearity (r2>0.9962, accuracy (recoveries ≥ 95.75%, precision (intraday variation ≤ 1.923%, interday variation ≤ 1.950%, limits of detection (LODs, and limits of quantification (LOQs parameters. LODs and LOQs for analytes were in the range of 0.10–0.19 μg/mL and 0.33–0.63 μg/mL, respectively. The proposed method was applied successfully for the simultaneous determination of the mixtures of five food additives and caffeine in soft drinks.

  4. [Reversed-phase high-performance liquid chromatograph--application to serum aluminium monitoring].

    Science.gov (United States)

    Hoshino, H; Kaneko, E

    1996-01-01

    High-Performance Liquid Chromatography (HPLC) with the reversed-phase partition mode separation (including ion-pair one) towards metal chelate compounds prepared in an off-line fashion (precolumn chelation) is most versatile in terms of high sensitivity with base-line flatness, unique selectivity and cost effectiveness. The extraordinary toughness to the complicated matrices encountered in clinical testing is exemplified by the successful application to the aluminium monitoring of human serum samples. The A1 chelate with 2,2'-dihydroxyazobenzene is efficiently chromatographed on a LiChroCART RP-18 column using an aqueous methanol eluent (63.6 wt%) containing tetrabutylammonium bromide as an ion-pair agent. The serum concentration level of A1 down to 6 micrograms dm-3 is readily monitored without influences from iron, chyle and haemolysis.

  5. Development and validation of a HPLC method for the assay of dapivirine in cell-based and tissue permeability experiments.

    Science.gov (United States)

    das Neves, José; Sarmento, Bruno; Amiji, Mansoor; Bahia, Maria Fernanda

    2012-12-12

    Dapivirine, a non-nucleoside reverse transcriptase inhibitor, is being currently used for the development of potential anti-HIV microbicide formulations and delivery systems. A new high-performance liquid chromatography (HPLC) method with UV detection was developed for the assay of this drug in different biological matrices, namely cell lysates, receptor media from permeability experiments and homogenates of mucosal tissues. The method used a reversed-phase C18 column with a mobile phase composed of trifluoroacetic acid solution (0.1%, v/v) and acetonitrile in a gradient mode. Injection volume was 50μL and the flow rate 1mL/min. The total run time was 12min and UV detection was performed at 290nm for dapivirine and the internal standard (IS) diphenylamine. A Box-Behnken experimental design was used to study different experimental variables of the method, namely the ratio of the mobile phase components and the gradient time, and their influence in responses such as the retention factor, tailing factor, and theoretical plates for dapivirine and the IS, as well as the peak resolution between both compounds. The optimized method was further validated and its usefulness assessed for in vitro and ex vivo experiments using dapivirine or dapivirine-loaded nanoparticles. The method showed to be selective, linear, accurate and precise in the range of 0.02-1.5μg/mL. Other chromatographic parameters, namely carry-over, lower limit of quantification (0.02μg/mL), limit of detection (0.006μg/mL), recovery (equal or higher than 90.7%), and sample stability at different storage conditions, were also determined and found adequate for the intended purposes. The method was successfully used for cell uptake assays and permeability studies across cell monolayers and pig genital mucosal tissues. Overall, the proposed method provides a simple, versatile and reliable way for studying the behavior of dapivirine in different biological matrices and assessing its potential as an anti

  6. Determination of two capsaicinoids in analgesic transdermal patches using RP-HPLC and UV spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Kobarfard

    2017-11-01

    Full Text Available Background and objectives: At the present time, a considerable frontier in the administration of therapeutic medications is transdermal drug delivery. Methods: In this study, a rapid, precise, sensitive and selective reversed-phasehigh performance liquid chromatography (RP-HPLC method has been evaluated, developed and validated to separate and quantitate capsaicin and dihydrocapsaicin (main active agents in analgesic dermal patches produced in Iran. Results: After isolation from laminated adhesive patches, capsaicinoids were analyzed on Lichrospher C18 analytical columns with reversed phase, using a mobile phase composition of methanol and distilled water (70:30 v/v and without any buffer (pH=6.5. The flow rate was 1 mL/min and the UV detector was operating at 281 nm. The assay was found to be linear over the range of 0.1-1.0 mg/mL. All validation parameters were within the acceptable range. Conclusion: It seems that the developed method was fairly sensitive and reliable in measuring capsaicinoids in commercially available analgesic transdermal patches in Iran.

  7. Buffer-Free High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, economical and reproducible high performance liquid chromatographic (HPLC) method for the determination of theophylline in pharmaceutical dosage forms. Method: Caffeine was used as the internal standard and reversed phase C-18 column was used to elute the drug and ...

  8. Measurement of the modification and interference rate of urinary albumin detected by size-exclusion HPLC

    International Nuclear Information System (INIS)

    Markó, Lajos; Molnár, Gergő Attila; Wagner, Zoltán; Szijártó, István; Mérei, Ákos; Wittmann, István; Böddi, Katalin; Szabó, Zoltán; Matus, Zoltán; Kőszegi, Tamás; Nagy, Géza

    2009-01-01

    The measurement of the excretion of urinary albumin (albuminuria) is an important and well-established method to assess clinical outcomes. A high-performance liquid chromatography (HPLC) method has been introduced to measure albuminuria. Using this method, it was found that commonly used immunological methods do not measure a fraction of urinary albumin. Some authors presumed that the reason of immuno-unreactivity is the modification of urinary albumin; some others presumed that the difference is merely because of interference. In order to decide this question, we established an HPLC method equipped with tandem UV and fluorescent detection to assess the changes in the detectability of albumin with the rate of modification. For this measurement, differently modified forms of albumin were used. Urine samples of diabetic patients were also measured to find a potential connection between the modification rate and clinical parameters. Secondly, we have established a reversed phase HPLC method to assess the interference rate. We conclude that albumin modification does not affect immunoreactivity. The modification rate of urinary albumin in diabetic patients showed a correlation with renal function. The interference rate of the albumin peak was found to be 12.7% on average, which does not explain the difference between the two methods

  9. Determination of organic acids evolution during apple cider fermentation using an improved HPLC analysis method

    NARCIS (Netherlands)

    Zhang, H.; Zhou, F.; Ji, B.; Nout, M.J.R.; Fang, Q.; Zhang, Z.

    2008-01-01

    An efficient method for analyzing ten organic acids in food, namely citric, pyruvic, malic, lactic, succinic, formic, acetic, adipic, propionic and butyric acids, using HPLC was developed. Boric acid was added into the mobile phase to separate lactic and succinic acids, and a post-column buffer

  10. High-performance liquid chromatography method with radiochemical detection for measurement of nitric oxide synthase, arginase, and arginine decarboxylase activities

    DEFF Research Database (Denmark)

    Volke, A; Wegener, Gregers; Vasar, E

    2006-01-01

    regulate NOS activity. We aimed to develop a HPLC-based method to measure simultaneously the products of these three enzymes. Traditionally, the separation of amino acids and related compounds with HPLC has been carried out with precolumn derivatization and reverse phase chromatography. We describe here...

  11. Determination of Arctiin and Arctigenin Contents in Arctium Tomentosum Mill. by HPLC Method

    OpenAIRE

    Xiaoying Zhou; Haoke Zhang; Liang Ge; Haiyan Gong; Shuge Tian

    2011-01-01

    A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in the Arctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18 column (250×4.6 mm, 5 μm, with pre-column), the mobile phase consists of methanol and water (55: 45). Detection wavelength was 280 nm. The speed of flow was 1....

  12. Influence of variation in mobile phase pH and solute pK(a) with the change of organic modifier fraction on QSRRs of hydrophobicity and RP-HPLC retention of weakly acidic compounds.

    Science.gov (United States)

    Han, Shu-ying; Liang, Chao; Zou, Kuan; Qiao, Jun-qin; Lian, Hong-zhen; Ge, Xin

    2012-11-15

    The variation in mobile phase pH and ionizable solute dissociation constant (pK(a)) with the change of organic modifier fraction in hydroorganic mobile phase has seemingly been a troublesome problem in studies and applications of reversed phase high performance liquid chromatography (RP-HPLC). Most of the early studies regarding the RP-HPLC of acid-base compounds have to measure the actual pH of the mixed mobile phase rigorously, sometimes bringing difficulties in the practices of liquid chromatographic separation. In this paper, the effect of this variation on the apparent n-octanol/water partition coefficient (K(ow)″) and the related quantitative structure-retention relationship (QSRR) of logK(ow)″ vs. logk(w), the logarithm of retention factor of analytes in neat aqueous mobile phases, was investigated for weakly acidic compounds. This QSRR is commonly used as a classical method for K(ow) measurement by RP-HPLC. The theoretical and experimental derivation revealed that the variation in mobile phase pH and solute pK(a) will not affect the QSRRs of acidic compounds. This conclusion is proved to be suitable for various types of ion-suppressors, i.e., strong acid (perchloric acid), weak acid (acetic acid) and buffer salt (potassium dihydrogen phosphate/phosphoric acid, PBS). The QSRRs of logK(ow)″ vs. logk(w) were modeled by 11 substituted benzoic acids using different types of ion-suppressors in a binary methanol-water mobile phase to confirm our deduction. Although different types of ion-suppressor all can be used as mobile phase pH modifiers, the QSRR model obtained by using perchloric acid as the ion-suppressor was found to have the best result, and the slightly inferior QSRRs were obtained by using acetic acid or PBS as the ion-suppressor. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. HPLC-DAD-ESI/MS Identification of Light Harvesting and Light Screening Pigments in the Lake Sediments at Edmonson Point

    OpenAIRE

    Giovannetti, Rita; Alibabaei, Leila; Zannotti, Marco; Ferraro, Stefano; Petetta, Laura

    2013-01-01

    The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC) with electrospray-mass spectrometry (ESI-MS) detection and diode array detection (DAD) has been used to identify light screeni...

  14. Methods and applications of HPLC-AMS

    International Nuclear Information System (INIS)

    Buchholz, Bruce A.; Dueker, Stephen R.; Lin, Yumei; Clifford, Andrew J.; Vogel, John S.

    2000-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a 14 C-labeled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the 14 C content above the control predose tissue and converting to equivalents of the parent compound. High performance liquid chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are tentatively identified by co-elution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the 14 C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of 14 C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected 14 C activity <0.17 Bq (4.5 pCi) on the HPLC column

  15. Establishment of analytical methods for analysis of pesticides and organic chlorides by hplc

    International Nuclear Information System (INIS)

    Ghaffar, A.; Mashiatullah, A.; Javed, T.

    2012-01-01

    Methods for the analysis of organic chlorides and pesticides like dichlorophenol (DCP), DDT, Chlorpyrifos, Cypermethrin, Melathion, Diazinon and Pendimathalin by HPLC equipped with UV detector were established. The methods were optimized by applying different wavelengths and by changing the composition of mobile phase and flow rates. A series of analysis were performed to optimize the solvent composition, flow rate and wave length for analysis. The standard solutions with different concentration were prepared and run on HPLC. The calibration curves constructed from the peak area versus concentrations were linear (r = 0. 99). Efficiency of the developed methods was tested by taking known quantities of compounds in sample media by spiking separate portions of samples and repeating the analysis. The accuracy of the established methods was checked by interference and spiking the samples with the standard solution. The sample was analyzed and spiked with equal volume of standard solution. The calculated and actual analyzed concentrations were compared for the accuracy of method. The recoveries of samples ranged between 96-98 %, which prove the accuracy of the established methods. (orig./A.B.)

  16. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    Science.gov (United States)

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were vitamins. Recovery percentages ranged from 93% to 100%.

  17. A VALIDATED STABILITY INDICATED RP-HPLC METHOD FOR DUTASTERIDE

    OpenAIRE

    D. Pavan Kumar a, b *, Naga Jhansi a, G. Srinivasa Rao b, Kirti Kumar Jain a

    2018-01-01

    ABSTRACT A Simple, Stability indicating, Isocratic, reverse phase High Performance Liquid Chromatographic (RPLC) related substance method was developed for Dutasteride in API. This method separates the impurities which are co-eluting in the pharmacopeia method. Successful separation of degradation impurities and synthetic impurities was achieved by YMC Triat phenyl column. Chromatographic was carried out on YMC Triat phenyl (150 X 4.6 mm, 3.0µm) column using 0.01M Potassium Dihydrogen Pho...

  18. A REVERSED PHASE HPLC METHOD FOR THE ANALYSIS OF ...

    African Journals Online (AJOL)

    Preferred Customer

    2009-04-10

    2Department of Chemistry and Chemical Engineering, Hunan Institute of Science and. Technology, 414000 Yueyang, China. (Received April 10, 2009; revised .... acid, methanol, acetonitrile (gradient grade for chromatography), perchloric acid 70%, sodium dihydrogen phosphatemonohydrate, and sodium hydroxide were ...

  19. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method

    OpenAIRE

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, MahmoudReza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 ?L of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase con...

  20. A Simple and Effective Isocratic HPLC Method for Fast Identification and Quantification of Surfactin

    International Nuclear Information System (INIS)

    Muhammad Qadri Effendy Mubarak; Abdul Rahman Hassan; Aidil Abdul Hamid; Sahaid Khalil; Mohd Hafez Mohd Isa

    2015-01-01

    The aim of this study was to establish a simple, accurate and reproducible method for the identification and quantification of surfactin using high-performance liquid chromatography (HPLC). Previously reported method of identification and quantification of surfactin were time consuming and requires a large quantity of mobile phase. The new method was achieved by application of Chromolith® high performance RP-18 (100 x 4.6 mm, 5 μm) as the stationary phase and optimization of mobile phase ratio and flow rate. Mobile phase consisted of acetonitrile (ACN) and 3.8 mM trifluroacetic acid (TFA) solution of 80:20 ratio at flow rate of 2.2 mL/ min was obtained as the optimal conditions. Total elution time of the obtained surfactin peaks was four times quicker than various methods previously reported in the literature. The method described here allowed for fine separation of surfactin in standard sample (98 % purity) and surfactin in fermentation broth. (author)

  1. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.

    Science.gov (United States)

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.

  2. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    Science.gov (United States)

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  3. The use of Fourier reverse transforms in crystallographic phase refinement

    Energy Technology Data Exchange (ETDEWEB)

    Ringrose, Sharon [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Often a crystallographer obtains an electron density map which shows only part of the structure. In such cases, the phasing of the trial model is poor enough that the electron density map may show peaks in some of the atomic positions, but other atomic positions are not visible. There may also be extraneous peaks present which are not due to atomic positions. A method for determination of crystal structures that have resisted solution through normal crystallographic methods has been developed. PHASER is a series of FORTRAN programs which aids in the structure solution of poorly phased electron density maps by refining the crystallographic phases. It facilitates the refinement of such poorly phased electron density maps for difficult structures which might otherwise not be solvable. The trial model, which serves as the starting point for the phase refinement, may be acquired by several routes such as direct methods or Patterson methods. Modifications are made to the reverse transform process based on several assumptions. First, the starting electron density map is modified based on the fact that physically the electron density map must be non-negative at all points. In practice a small positive cutoff is used. A reverse Fourier transform is computed based on the modified electron density map. Secondly, the authors assume that a better electron density map will result by using the observed magnitudes of the structure factors combined with the phases calculated in the reverse transform. After convergence has been reached, more atomic positions and less extraneous peaks are observed in the refined electron density map. The starting model need not be very large to achieve success with PHASER; successful phase refinement has been achieved with a starting model that consists of only 5% of the total scattering power of the full molecule. The second part of the thesis discusses three crystal structure determinations.

  4. Methodology for determination of benzimidazolic fungicides residues in strawberry and lettuce by HPLC-DAD

    International Nuclear Information System (INIS)

    Dangond Araujo, Jose Jairo; Guerrero dallos, Jairo Arturo

    2006-01-01

    systemic fungicides like benzimidazolic compounds are used to protect several crops of fruits and vegetables. in this work a new method for analysis of Benomyl, carbendazim and thiabendazol in strawberry and lettuce by high performance liquid chromatography with diode array detector (HPLC-DAD) was validated. benomyl residues were determined after its conversion to carbendazim. pesticide residues were extracted from strawberry and lettuce samples with ethyl acetate and these extracts were cleaned up by gel permeation chromatography (GPC). final determination was carried out by HPLC-DAD in reverse phase column. the method is selective, specific, precise and accurate. the calibration curves show linearity over concentration range of 1.24 to 6.19 mg/kg, with detection limits of 0.40 and 0.27 mg/kg and quantification limits of 1.35 and 0.81 mg/kg for carbendazim and thiabendazole respectively. the recovery experiments yielding averages of 90 %. n o residues of these compounds were found in collected samples from specific areas of Cundinamarca, Colombia

  5. Simultaneous Determination of TetracyclinesResidues in Bovine Milk Samples by Solid Phase Extraction and HPLC-FL Method

    Directory of Open Access Journals (Sweden)

    Mehra Mesgari Abbasi

    2011-06-01

    Full Text Available Introduction:Tetracyclines (TCs are widely used in animal husbandry and their residues in milk may resultinharmful effects on human. The aim of this study was to investigate the presence of TCs residues in various bovine milk samples from local markets of Ardabil, Iran. Methods:One hundred and fourteen pasteurized, sterilized and raw milk samples were collected from markets of Ardabil. Tetracycline, Oxytetracycline and Chlortetracycline (TCs residues extraction carried out by Solid Phase Extraction method. Determination of TCs residues were performed by high performance liquid chromatography (HPLC method using Fluorescence detector.Results: The mean of total TCs residues in all samples (114 samples was 97.6 ±16.9ng/g and that of pasteurized, sterilized and raw milk samples were 87.1 ± 17.7, 112.0 ± 57.3 and 154.0 ± 66.3ng/g respectively. Twenty five point four percent of the all samples, and24.4%, 30% and 28.6% of the pasteurized, sterilized and raw milk samples, respectively had higher TCs residues than the recommended maximum levels (100ng/g. Conclusion:This study indicates the presence of tetracycline residues more than allowed amount. Regulatory authorities should ensure proper withdrawal period before milking the animals and definite supervisions are necessary on application of these drugs.

  6. Development and validation of a reversed phase High Performance ...

    African Journals Online (AJOL)

    A simple, rapid, accurate and economical isocratic Reversed Phase High Performance Liquid Chromatography (RPHPLC) method was developed, validated and used for the evaluation of content of different brands of paracetamol tablets. The method was validated according to ICH guidelines and may be adopted for the ...

  7. Identification of ionic chloroacetanilide-herbicide metabolites in surface water and groundwater by HPLC/MS using negative ion spray

    Science.gov (United States)

    Ferrer, I.; Thurman, E.M.; Barcelo, D.

    1997-01-01

    Solid-phase extraction (SPE) was combined with high-performance liquid chromatography/high-flow pneumatically assisted electrospray mass spectrometry (HPLC/ESP/MS) for the trace analysis of oxanilic and sulfonic acids of acetochlor, alachlor, and metolachlor. The isolation procedure separated the chloroacetanilide metabolites from the parent herbicides during the elution from C18 cartridges using ethyl acetate for parent compounds, followed by methanol for the anionic metabolites. The metabolites were separated chromatographically using reversed-phase HPLC and analyzed by negative-ion MS using electrospray ionization in selected ion mode. Quantitation limits were 0.01 ??g/L for both the oxanilic and sulfonic acids based on a 100-mL water sample. This combination of methods represents an important advance in environmental analysis of chloroacetanilide-herbicide metabolites in surface water and groundwater for two reasons. First, anionic chloroacetanilide metabolites are a major class of degradation products that are readily leached to groundwater in agricultural areas. Second, anionic metabolites, which are not able to be analyzed by conventional methods such as liquid extraction and gas chromatography/mass spectrometry, are effectively analyzed by SPE and high-flow pneumatically assisted electrospray mass spectrometry. This paper reports the first HPLC/MS identification of these metabolites in surface water and groundwater.

  8. Metabolite profiling with HPLC-ICP-MS as a tool for in vivo characterization of imaging probes.

    Science.gov (United States)

    Boros, Eszter; Pinkhasov, Omar R; Caravan, Peter

    2018-01-01

    Current analytical methods for characterizing pharmacokinetic and metabolic properties of positron emission tomography (PET) and single photon emission computed tomography (SPECT) probes are limited. Alternative methods to study tracer metabolism are needed. The study objective was to assess the potential of high performance liquid chromatography - inductively coupled plasma - mass spectrometry (HPLC-ICP-MS) for quantification of molecular probe metabolism and pharmacokinetics using stable isotopes. Two known peptide-DOTA conjugates were chelated with nat Ga and nat In. Limit of detection of HPLC-ICP-MS for 69 Ga and 115 In was determined. Rats were administered 50-150 nmol of Ga- and/or In-labeled probes, blood was serially sampled, and plasma analyzed by HPLC-ICP-MS using both reverse phase and size exclusion chromatography. The limits of detection were 0.16 pmol for 115 In and 0.53 pmol for 69 Ga. Metabolites as low as 0.001 %ID/g could be detected and transchelation products identified. Simultaneous administration of Ga- and In-labeled probes allowed the determination of pharmacokinetics and metabolism of both probes in a single animal. HPLC-ICP-MS is a robust, sensitive and radiation-free technique to characterize the pharmacokinetics and metabolism of imaging probes.

  9. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine: A Validation Study and Application

    Directory of Open Access Journals (Sweden)

    Margherita Grotzkyj Giorgi

    2012-01-01

    Full Text Available An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12 in biological matrices (plasma and urine. Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males. Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  10. Simultaneous measurement of cholesterol 7 alpha-hydroxylase activity by reverse-phase high-performance liquid chromatography using both endogenous and exogenous [4-14C]cholesterol as substrate

    International Nuclear Information System (INIS)

    Hylemon, P.B.; Studer, E.J.; Pandak, W.M.; Heuman, D.M.; Vlahcevic, Z.R.; Chiang, J.Y.

    1989-01-01

    The HPLC-spectrophotometric method for measuring cholesterol 7 alpha-hydroxylase activity was modified by using a C-18 reverse-phase column to separate 7 alpha-hydroxy-4-cholesten-3-one and 4-cholesten-3-one and by adding 7 beta-hydroxycholesterol to each reaction mixture as an internal recovery standard. With this method, we were able to simultaneously measure cholesterol 7 alpha-hydroxylase activity using endogenous cholesterol and exogenous [4- 14 C]cholesterol as substrate. Rat liver cytosol differentially stimulated (286%) the 7 alpha-hydroxylation of exogenous [4- 14 C]-cholesterol. In contrast, total cholesterol 7 alpha-hydroxylase activity was stimulated only 35% by cytosol. This method should prove useful for studying mechanisms of cholesterol delivery to cholesterol 7 alpha-hydroxylase

  11. Ion-pairing reversed-phase chromatography coupled to inductively coupled plasma mass spectrometry as a tool to determine mercurial species in freshwater fish.

    Science.gov (United States)

    Cheng, Heyong; Chen, Xiaopan; Shen, Lihuan; Wang, Yuanchao; Xu, Zigang; Liu, Jinhua

    2018-01-05

    Most of analytical community is focused on reversed phase high performance liquid chromatography (RP-HPLC) for mercury speciation by employing mobile phases comprising of high salts and moderate amounts of organic solvents. This study aims at rapid mercury speciation analysis by ion-pairing RP-HPLC with inductively coupled plasma mass spectrometry (ICP-MS) detection only using low salts for the sake of green analytical chemistry. Two ion-pairing HPLC methods were developed on individual usage of positively and negatively charged ion-pairing reagents (tetrabutylammonium hydroxide -TBAH and sodium dodecylbenzene sulfonate -SDBS), where sodium 3-mercapto-1-propysulfonate (MPS) and l-cysteine (Cys) were individually added in mobile phases to transform mercury species into negative and positive Hg-complexes for good resolution. Addition of phenylalanine was also utilized for rapid baseline separation in combination of short C 18 guard columns. Optimum mobile phases of 2.0mM SDBS+2.0mM Cys+1.0mM Phe (pH 3.0) and 4.0mM TBAH+2.0mM MPS+2.0mM Phe (pH 6.0) both achieved baseline separation of inorganic mercury (Hg 2+ ), methylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) on two consecutive 12.5-mm C 18 columns. The former mobile phase was selected for mercury speciation in freshwater fish because of short separation time (3.0min). Detection limits of 0.015 for Hg 2+ , 0.014 for MeHg, 0.028 for EtHg and 0.042μgL -1 for PhHg were obtained along with satisfactory precisions of peak height and area (1.0-2.8% for 5.0μgL -1 Hg-mixture standard). Good accordance of determined values of MeHg and total mercury in certified reference materials of fish tissue (GBW 10029) and tuna fish (BCR-463) with certified values as well as good recoveries (91-106%) proved good accuracy of the proposed method. An example application to freshwater fish indicated its potential in routine analysis, where MeHg was presented at 3.7-20.3μgkg -1 as the dominate species. Copyright © 2017

  12. Determination of Arctiin and Arctigenin Contents in Arctium Tomentosum Mill. by HPLC Method

    Directory of Open Access Journals (Sweden)

    Xiaoying Zhou

    2011-01-01

    Full Text Available A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in the Arctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18 column (250×4.6 mm, 5 μm, with pre-column, the mobile phase consists of methanol and water (55: 45. Detection wavelength was 280 nm. The speed of flow was 1.0 mL/min. The specimen handing quantity was 10 μL. The arctiin’s linearity range was 1.575∼4.725 μg (r=0.9995. The arctigenin’s linearity range was 0.613, 3.063 μg (r = 0.9998 and the linear relationship was accurate. The average recovery (n=5 of arctiin and arctigenin were 101.55% (RSD=2.23% 101.63% (RSD =1.49 % respectively. The contents of arctiin and arctigenin in Arctium tomentosum Mill. were 10.69 mg/g and 0.15 mg/g, respectively. Therefore, the developed HPLC method can be applied to both in vitro studies of arctiin and arctigenin formulations as well as drug estimation in biological samples.

  13. Validation of an HPLC method for determination of chemical purity of [18F]fluoromisonidazole ([18F]FMISO)

    International Nuclear Information System (INIS)

    Nascimento, Natalia C.E.S.; Oliveira, Mércia L.; Lima, Fernando R.A.; Silveira, Marina B.; Ferreira, Soraya Z.; Silva, Juliana B.

    2017-01-01

    [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) is a nitroimidazole derivative labelled with fluorine-18 that selectively binds to hypoxic cells. It has been shown to be a suitable PET tracer for imaging hypoxia in tumors as well as in noncancerous tissues. [ 18 F]FMISO was prepared using a TRACERlabMX FDG ® module (GE) with cassettes, software sequence and reagents kits from ABX. In this work, we aimed to develop and to validate a new high performance liquid chromatography (HPLC) method for determination of chemical purity of [ 18 F]FMISO. Analyses were performed with an Agilent chromatograph equipped with radioactivity and UV detectors. [ 18 F]FMISO and impurities were separated on a C18 column by gradient elution with water and acetonitrile. Selectivity, linearity, detection limit (DL), quantification limit (LQ), precision, accuracy and robustness were assessed to demonstrate that the HPLC method is adequate for its intended purpose. The HPLC method showed a good precision, as all RSD values were lower than 5%. Robustness was evaluated considering a variation on parameters such mobile phase gradient and flow rate. Results evidenced that the HPLC method is validated and is suitable for radiochemical purity evaluation of [ 18 F]FMISO, considering operational conditions of our laboratory. As an extension of this work, other analytical methods used for [ 18 F]FMISO quality control should be evaluated, in compliance with good manufacture practice. (author)

  14. Analytical Method Development and Validation of Solifenacin in Pharmaceutical Dosage Forms by RP-HPLC

    OpenAIRE

    Shaik, Rihana Parveen; Puttagunta, Srinivasa Babu; Kothapalli Bannoth, Chandrasekar; Challa, Bala Sekhara Reddy

    2014-01-01

    A new, accurate, precise, and robust HPLC method was developed and validated for the determination of solifenacin in tablet dosage form. The chromatographic separation was achieved on an Inertsil ODS 3V C18 (150 mm × 4.6 mm, 5 μm) stationary phase maintained at ambient temperature with a mobile phase combination of monobasic potassium phosphate (pH 3.5) containing 0.1% triethylamine and methanol (gradient mode) at a flow rate of 1.5 mL/min, and the detection was carried out by using UV detect...

  15. Measurement of purine derivatives and creatinine in urine by HPLC

    International Nuclear Information System (INIS)

    Piani, B.; Fabro, C.; Susmel, P.

    2004-01-01

    Two HPLC methods to measure the purine derivatives (PD, including allantoin, uric acid, hypoxanthine and xanthine) and creatinine content in urine are described. PD separation and quantification were achieved using two Spherisorb ODS 2 reversed phase columns connected in series (4.6 x 250 mm) and a Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), which was used at a flow rate of 0.8 ml/min and the detection wavelength was at 190 nm. The average recoveries of standard compounds added to urine samples were satisfactory (92-106%) and the low detection limits (0.7-3.4 μM) permitted the precise determination of these compounds in urine. Separation and quantification of creatinine was achieved using one Spherisorb ODS 2 reversed phase column (4.6 x 250 mm) and one Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), used at a flow rate of 1.00 ml/min and the detection was at 190 nm. The mean recovery (3 measurements) of standard solution added to urine samples was 101%; detection limit was 7.9 μM. (author)

  16. Reverse Schreinemakers Method for Experimental Analysis of Mixed-Solvent Electrolyte Systems

    DEFF Research Database (Denmark)

    Fosbøl, Philip Loldrup; Thomsen, Kaj; Stenby, Erling Halfdan

    2009-01-01

    the reverse Schreinemakers (RS) method. The method is based on simple mass balance principles similar to the wet residues method. It allows for accurate determination of the mixed-solvent phase composition even though part of the solvent may precipitate as complexes between solvent and salt. Discrepancies......A method based on Schreinemakers's tie-line theory of 1893 is derived for determining the composition and phase amounts in solubility experiments for multi-solvent electrolyte systems. The method uses the lever rule in reverse compared to Schreinemakers's wet residue method, and is therefore called...... from determining the composition of salt mixtures by pH titration are discussed, and the derived method significantly improves the obtained result from titration. Furthermore, the method reduces the required experimental work needed for analysis of phase composition. The method is applicable to multi...

  17. Dual Wavelength RP-HPLC Method for Simultaneous Determination of Two Antispasmodic Drugs: An Application in Pharmaceutical and Human Serum

    Directory of Open Access Journals (Sweden)

    Najmul Hasan

    2013-01-01

    Full Text Available A reverse phase stability indicating HPLC method for simultaneous determination of two antispasmodic drugs in pharmaceutical parenteral dosage forms (injectable and in serum has been developed and validated. Mobile phase ingredients consist of Acetonitrile : buffer : sulfuric acid 0.1 M (50 : 50 : 0.3 v/v/v, at flow rate 1.0 mL/min using a Hibar μBondapak ODS C18 column monitored at dual wavelength of 266 nm and 205 nm for phloroglucinol and trimethylphloroglucinol, respectively. The drugs were subjected to stress conditions of hydrolysis (oxidation, base, acid, and thermal degradation. Oxidation degraded the molecule drastically while there was not so much significant effect of other stress conditions. The calibration curve was linear with a correlation coefficient of 0.9999 and 0.9992 for PG and TMP, respectively. The drug recoveries fall in the range of 98.56% and 101.24% with 10 pg/mL and 33 pg/mL limit of detection and limit of quantification for both phloroglucinol and trimethylphloroglucinol. The method was validated in accordance with ICH guidelines and was applied successfully to quantify the amount of trimethylphloroglucinol and phloroglucinol in bulk, injectable form and physiological fluid. Forced degradation studies proved the stability indicating abilities of the method.

  18. HPLC studies of aquatic humic compounds and complexes from the Drigg Research Site, Cumbria

    International Nuclear Information System (INIS)

    Smith, B.

    1991-01-01

    This report describes an investigation into the applicability of high performance liquid chromatographic techniques for the separation of the complex mixtures of organic acids commonly found in groundwaters. This work has shown that reverse phase ion-pair chromatography using a large pore stationary phase can be successfully applied to humic material in both natural and concentrated groundwater from the Drigg Research Site. The methodology separates the organic species into a number of well resolved components the majority of which have a molecular weight of greater than 500 Dalton. Separations obtained have been qualitatively and quantitatively analysed using a Diode array spectrophotometer. The components in excess of 500 Dalton show UV absorption spectra similar to humic and fulvic acids where as the component with a molecular weight of less than 500 Dalton shows a sharp UV absorption cutoff at 230 nm. It was noted that this component was not removed by passage through DEAEA cellulose. Reverse phase HPLC was also investigated, and results were found to be consistent with a separation based on an ion-repulsion/size exclusion mechanism. It was concluded that any separation based on this mechanism is likely to suffer from poor inter run reproducibility and must therefore be discounted as a suitable method. Similarly, ion-suppression reverse phase was shown to be equally impracticable, requiring a mobile phase pH of less than 2 to obtain separation (this low pH renders a silica based stationary phase unstable). (author)

  19. Optimized Analytical Method to Determine Gallic and Picric Acids in Pyrotechnic Samples by Using HPLC/UV (Reverse Phase); Optimizacion del Metodo Analitico mediante HPLC/UV Operando en Fase Inversa para la Determinacion de Acido Galico y Acido Picrico en Muestras de Origen Pirotecnico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Alonso, S.; Perez Pastor, R. M.

    2013-10-01

    A study on the optimization and development of a chromatographic method for the determination of gallic and picric acids in pyrotechnic samples is presented. In order to achieve this, both analytical conditions by HPLC with diode detection and extraction step of a selected sample were studied. (Author)

  20. Develop and validation of an analytic method for the histamine determination in fish, using chromatography liquidates of high efficiency in reverse phase with ultraviolet detection

    International Nuclear Information System (INIS)

    Valverde Chavarria, J. C.

    1997-01-01

    There were determined and optimized the reaction and conditions analysis, for the derivation of the histamine with the reagent of or-ftalaldehido (OPA), it was proven that it is possible to quantify the one derived formed at 333nm. The good conditions crhomatografics settled down for the determination of the histamine in fish by means of the analytic technique of chromatography it liquidates of high efficiency (HPLC) in reverse phase, using the derivatizacion in precolumn of the histamine with the reagent of OPA, with ultraviolet detection at 333nm. The conditions of the proposed methodology were optimized and the variables of analytic acting were validated, for the analytic quantification of the histamine in the mg g-1 environment. The applicability of the methodology was demonstrated in the histamine determination in samples of fresh fish [es

  1. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods

    Science.gov (United States)

    Dragoi, D.; Kanik, I.; Bar-Cohen, Y.; Sherrit, S.; Tsapin, A.; Kulleck, J.

    2004-01-01

    In this work we describe an analytical method for determining the presence of organic compounds in rocks, limestone, and other composite materials. Our preliminary laboratory experiments on different rocks/limestone show that the organic component in mineralogical matrices is a minor phase on order of hundreds of ppm and can be better detected using high precision liquid chromatography (HPLC). The matrix, which is the major phase, plays an important role in embedding and protecting the organic molecules from the harsh Martian environment. Some rocks bear significant amounts of amino acids therefore, it is possible to identify these phases using powder x-ray diffraction (XRD) by crystallizing the organic. The method of detection/analysis of organics, in particular amino acids, that have been associated with life will be shown in the next section.

  2. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  3. Simultaneous determination of triple therapy for Helicobacter pylori in human plasma by reversed phase chromatography with online wavelength switching

    Science.gov (United States)

    Ahmed, Sameh; Atia, Noha N.

    2015-02-01

    The infection of gastric mucosa by Helicobacter pylori (HP) is an essential cofactor in the aetiology of gastroduodenal ulcer and gastric carcinoma. Because of the bacterial resistance, combination therapy containing omeprazole (OME), tinidazole (TNZ) and clarithromycin (CLA) is commonly used for eradication of HP. However, the simultaneous determination of the triple therapy in human plasma was not reported. A simple, reproducible, and selective HPLC method was developed for the simultaneous determination of the triple therapy mixture used for management of HP infections in human plasma. An HPLC procedure based on a liquid-liquid extraction, enrichment of the analytes and subsequent reversed-phase chromatography with UV detection was used. To enable sensitive and selective detection, the method involved the use of online wavelength switching detection, with two different detection wavelengths; 280 nm for detection of OME and TNZ and 210 nm for detection of CLA. Separations were performed on C18 analytical column with acetonitrile-10 mM phosphate buffer of pH = 3.0 at flow rate of 1.0 mL min-1. The linear ranges in human plasma were 0.05-10 μg mL-1 with correlation coefficients >0.9990. The detection limits in human plasma were 0.02-0.07 μg mL-1. Validation parameters were assessed in compliance with US-FDA guidelines. The method proved to be valuable for the therapeutic drug monitoring after oral administration of triple therapy tablets.

  4. Estimation of Duloxetine Hydrochloride in Pharmaceutical Formulations by RP-HPLC Method

    OpenAIRE

    Patel, Sejal K.; Patel, N. J.; Patel, K. M.; Patel, P. U.; Patel, B. H.

    2008-01-01

    Simple, specific, accurate and precise method, namely, reverse phase high performance liquid chromatography was developed for estimation of duloxetine HCl in pharmaceutical formulations. For the high performance liquid chromatography method, Phenomenox C-18, 5 µm column consisting of 250x4.6 mm i.d. in isocratic mode, with mobile phase containing 0.01M 5.5 pH phosphate buffer: acetonitrile (60:40 v/v) and final pH adjust to 5.5±0.02 with phosphoric acid was used. The flow rate w...

  5. Ultrasound-assisted extraction of azadirachtin from dried entire fruits of Azadirachta indica A. Juss. (Meliaceae) and its determination by a validated HPLC-PDA method.

    Science.gov (United States)

    de Paula, Joelma Abadia Marciano; Brito, Lucas Ferreira; Caetano, Karen Lorena Ferreira Neves; de Morais Rodrigues, Mariana Cristina; Borges, Leonardo Luiz; da Conceição, Edemilson Cardoso

    2016-01-01

    Azadirachta indica A. Juss., also known as neem, is a Meliaceae family tree from India. It is globally known for the insecticidal properties of its limonoid tetranortriterpenoid derivatives, such as azadirachtin. This work aimed to optimize the azadirachtin ultrasound-assisted extraction (UAE) and validate the HPLC-PDA analytical method for the measurement of this marker in neem dried fruit extracts. Box-Behnken design and response surface methodology (RSM) were used to investigate the effect of process variables on the UAE. Three independent variables, including ethanol concentration (%, w/w), temperature (°C), and material-to-solvent ratio (gmL(-1)), were studied. The azadirachtin content (µgmL(-1)), i.e., dependent variable, was quantified by the HPLC-PDA analytical method. Isocratic reversed-phase chromatography was performed using acetonitrile/water (40:60), a flow of 1.0mLmin(-1), detection at 214nm, and C18 column (250×4.6mm(2), 5µm). The primary validation parameters were determined according to ICH guidelines and Brazilian legislation. The results demonstrated that the optimal UAE condition was obtained with ethanol concentration range of 75-80% (w/w), temperature of 30°C, and material-to-solvent ratio of 0.55gmL(-1). The HPLC-PDA analytical method proved to be simple, selective, linear, precise, accurate and robust. The experimental values of azadirachtin content under optimal UAE conditions were in good agreement with the RSM predicted values and were superior to the azadirachtin content of percolated extract. Such findings suggest that UAE is a more efficient extractive process in addition to being simple, fast, and inexpensive. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Development and Validation of a UV Spectrophotometric and a RP-HPLC Methods for Moexipril Hydrochloride in Pure Form and Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Mastiholimath, V.S.; Gupte, P.P.; Mannur, V.S.

    2012-01-01

    A simple and reliable UV spectrophotometric and high-performance liquid chromatography (HPLC) methods were developed and validated for Moexipril hydrochloride in pure form and pharmaceutical dosage form. The RP-HPLC method was developed on agilant eclipse C 18 , (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of 60 % (methanol:acetonitrile (70:30 % v/v)) : 40 % 20 mM ammonium acetate buffer pH 4.5 (v/v) and UV spectrophotometric method was developed in phosphate buffer pH 6.8. The effluent was monitored by SPD-M20A, prominence PDA detector at 210 nm. Calibration curve was linear over the concentration range of 10-35 μg/ml and 1-9 μg/ml for RP-HPLC and UV with a regression coefficient of 0.999. For RP-HPLC method Inter-day and intra-day precision % RSD values were found to be 1.00078 % and 1.49408 % respectively. For UV method 0.73386 % to 1.44111 % for inter day 0.453864 to 1.15542 intra-day precision. Recovery of Moexipril hydrochloride was found to be in the range of 99.8538 % to 101.5614 % and 100.5297586 % to 100.6431587 % for UV and RP-HPLC respectively. The limits of detection (LOD) and quantification (LOQ) for HPLC were 0.98969 and 2.99907 μg/ml, respectively. The developed RP-HPLC and UV spectrophotometric method was successfully applied for the quantitative determination of Moexipril hydrochloride in pharmaceutical dosage. (author)

  7. Stability Indicating RP-HPLC Method for Simultaneous Determination of Aspirin and Clopidrogel in Dosage Form

    International Nuclear Information System (INIS)

    Mohd Gousuddin; Sengupta, P.; Tripathi, V.D.; Das, A.

    2016-01-01

    Stability-indicating High Performance Liquid Chromatographic (HPLC) method was developed for simultaneous Aspirin and Clopidogrel, A Phenomenex Gemini C-18, 5 μm column having 250 mm x 4.6 mm i.d. in isocratic mode, with mobile phase containing buffer solution 0.3 % orthophosphoric acid : acetonitrile (65:35, v/v). The flow rate was 1 ml/ min and effluents were monitored at 266 nm. For linearity seven points calibration curve were obtained in a concentration range from 0.030-0.120 mg/ ml for aspirin and 0.015-0.060 mg/ ml for clopidogrel with correlation coefficient 0.9999. In the present study stability indicating HPLC method for the combination was tested by degrading the drugs together under various stress conditions like acid hydrolysis, base hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH guideline. (author)

  8. Analysis of nine food additives in red wine by ion-suppression reversed-phase high-performance liquid chromatography using trifluoroacetic acid and ammonium acetate as ion-suppressors.

    Science.gov (United States)

    Zhao, Yong-Gang; Chen, Xiao-Hong; Yao, Shan-Shan; Pan, Sheng-Dong; Li, Xiao-Ping; Jin, Mi-Cong

    2012-01-01

    A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in red wine. The effects of ion-suppressors, i.e., trifluoroacetic acid (TFA) and ammonium acetate (AmAc) on retention behavior of nine food additives in RP-HPLC separation were discussed in detail. The relationships between retention factors of solutes and volume percent of ion-suppressors in the mobile-phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, respectively. The results showed that the ion suppressors had not only an ion suppression effect, but also an organic modification effect on the acidic analytes. The baseline separation of nine food additives was completed by a gradient elution with acetonitrile-TFA(0.01%, v/v)-AmAc(2.5 mmol L(-1)) aqueous solution as the mobile phase. The recoveries were between 80.2 - 99.5% for all analytes with RSDs in the range of 1.5 - 8.9%. The linearities were in the range of 0.2 - 100.0 mg L(-1) with determination coefficients (r(2)) higher than 0.9991 for all analytes. The limits of quantification (LOQs) were between 0.53 - 0.99 mg L(-1). The applicability of the proposed method to detect and quantify food additives has been demonstrated in the analysis of 30 real samples.

  9. HPLC-DAD-ESI/MS identification of light harvesting and light screening pigments in the lake sediments at Edmonson Point.

    Science.gov (United States)

    Giovannetti, Rita; Alibabaei, Leila; Zannotti, Marco; Ferraro, Stefano; Petetta, Laura

    2013-01-01

    The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC) with electrospray-mass spectrometry (ESI-MS) detection and diode array detection (DAD) has been used to identify light screening and light harvesting pigments. The results are discussed in terms of local environmental conditions.

  10. Analysis of Wheat Prolamins, the Causative Agents of Celiac Sprue, Using Reversed Phase High Performance Liquid Chromatography (RP-HPLC and Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS

    Directory of Open Access Journals (Sweden)

    Jaime H. Mejías

    2014-04-01

    Full Text Available Wheat prolamins, commonly known as “gluten”, are a complex mixture of 71–78 proteins, which constitute ~80% of the proteins in the wheat grains and supply 50% of the global dietary protein demand. Prolamins are also responsible for numerous gluten-induced disorders and determine the unique visco-elastic properties of the wheat dough. These properties necessitate the reliable determination of the prolamin composition in wheat grains and their derived products. Therefore, this study examined the impact of HPLC conditions, including column type, column temperature, flow rate, and the gradient of polar and non-polar solvents in the mobile phase, to improve the analytical resolution of prolamins. The following conditions were found optimal for analyses: column temperature 60 °C, flow rate 1.0 mL/min and an elution gradient of 20%–60% of 0.1% trifluoroacetic acid + acetonitrile in 60 min. For further improvement of resolution, gliadin and glutenin extracts were analyzed using MALDI-TOF-MS in combination with HPLC fractionation. Two semi-quantitative methods, densitometry of stained polyacrylamide gels and HPLC, were used to determine relative prolamin quantities and the correspondence between the methods was established. The combinatorial gluten analyses approach developed during the present study was used to analyze prolamin profiles of wheat transformants expressing DEMETER silencing artificial microRNA, and the results are discussed.

  11. The concentration of trans-lycopene in postharvest watermelon: An evaluation of analytical data obtained by direct methods

    NARCIS (Netherlands)

    Dimitrovski, D.; Bicanic, D.D.; Luterotti, S.; Twisk, van C.; Buijnsters, J.G.; Doka, O.

    2010-01-01

    The performance of the newly proposed laser-based optothermal window (OW) method and colorimetry for quantification of trans -lycopene in 10 watermelon homogenates has been evaluated. Reverse phase HPLC served as an established reference method. Both, OW and colorimetry are direct methods as they,

  12. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    International Nuclear Information System (INIS)

    Jitaru, Petru; Goenaga-Infante, Heidi; Vaslin-Reimann, Sophie; Fisicaro, Paola

    2010-01-01

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  13. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jitaru, Petru, E-mail: Petru.Jitaru@lne.fr [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France); Goenaga-Infante, Heidi [LGC Limited, Queens Road, Teddington, TW11 OLY, Middlesex (United Kingdom); Vaslin-Reimann, Sophie; Fisicaro, Paola [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France)

    2010-01-11

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  14. Simultaneous determination of bioactive constituents in Danggui Buxue Tang for quality control by HPLC coupled with a diode array detector, an evaporative light scattering detector and mass spectrometry.

    Science.gov (United States)

    Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun

    2007-09-01

    Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.

  15. HPLC Separation of Sulforaphane Enantiomers in Broccoli and Its Sprouts by Transformation into Diastereoisomers Using Derivatization with (S)-Leucine.

    Science.gov (United States)

    Okada, Makiko; Yamamoto, Atsushi; Aizawa, Sen-Ichi; Taga, Atsushi; Terashima, Hiroyuki; Kodama, Shuji

    2017-01-11

    Racemic sulforaphane, which was derivatized with (S)-leucine (l-leucine), was resolved by reversed phase HPLC with UV detection. The optimum mobile phase conditions were found to be 10 mM citric acid (pH 2.8) containing 22% methanol at 35 °C using detection at 254 nm. Sulforaphane enantiomers in florets and stems of five brands of broccoli and leaves and stems of three brands of broccoli sprouts were analyzed by the proposed HPLC method. Both sulforaphane enantiomers were detected in all of the samples. The S/R ratios of sulforaphane in broccoli samples were 1.5-2.6/97.4-98.5% for florets and 5.0-12.1/87.9-95.0% for stems. The S/R ratios in broccoli sprout samples were higher than those in broccoli samples and were found to be 8.3-19.7/80.3-91.7% for leaves and 37.0-41.8/58.2-63.0% for stems. (S)-Sulforaphane detected in the broccoli and its sprout samples was positively identified by separately using an HPLC with a chiral column (Chiralpak AD-RH) and mass spectrometry.

  16. Ion-pairing reversed-phased chromatography/mass spectrometry of heparin

    DEFF Research Database (Denmark)

    Henriksen, Jens; Roepstorff, Peter; Ringborg, Lene H.

    2006-01-01

    not well characterised. In order to further characterise such mixtures, two on-line ion-pairing reverse-phased chromatography electrospray ionisation (ESI) mass spectrometry methods have been developed. One of the systems allows the determination of more than 200 components in a medium molecular weight...

  17. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    phase high performance liquid chromatography (RP-HPLC) to determine mitragynine (MG) in rat and human urine, and to investigate the influence of caffeine (CF) on urinary excretion of MG in rats. Methods: A two-dimensional wash-elute ...

  18. RP-HPLC Determination of vitamins B1, B3, B6, folic acid and B12 in multivitamin tablets

    Directory of Open Access Journals (Sweden)

    SOTE VLADIMIROV

    2005-10-01

    Full Text Available Abstract:Asimple and sensitive reversed-phase, ion-pair HPLC method was developed and validated for the simultaneous determination of B-group vitamins, thiamine chloride hydrochloride (B1, nicotinamide (B3, pyridoxine hydrochloride (B6 and folic acid in Pentovit® coated tablets. The cyanocobalamine (B12 was determined separately, because of its low concentration in the investigated multivitamin preparation. RP-HPLC analysis was performed with a LKB 2150 HPLC system, equipped with a UV/VIS Waters M484 detector. The procedures for the determination of B1, B2, B6 and folic acid were carried out on a Supelcosil ABZ+ (15 cm 4.6 mm; 5 µm column with methanol-5mM heptanesulphonic acid sodium salt 0.1%triethylamine TEA(25:75 V/V; pH 2.8 as themobile phase. For the determination of B12 a Suplex pKb-100 (15 cm 4.6 mm; 5 µm column andmethanol–water (22:78 V/V as themobile phase were used. The column effluentsweremonitored at 290 nm for B 1, B3, B6 and folic acid, and at 550 nm for B12. The obtained results and statistical parameters for all the investigated vitamins of the B-group in Pentovit® coated tablets were satisfactory and ranged from 90.4 % to 108.5 % (RSD. from 0.5% to 4.1 %. The parameters for the validation of the methods are given.

  19. Recent developments in HPLC analysis of β-blockers in biological samples.

    Science.gov (United States)

    Saleem, Kishwar; Ali, Imran; Kulsum, Umma; Aboul-Enein, Hassan Y

    2013-09-01

    β-Adrenergic blockers represent a very important class of drugs that are used worldwide for treating various cardiac diseases. The present article describes the state-of-the art of analyses of β-adrenergic blockers using high-performance liquid chromatography (HPLC). Sample preparation techniques such as liquid-liquid extraction, solid-phase extraction and solid-phase microextraction have been discussed, which are essential prior to HPLC analysis. Additionally, applications of liquid chromatography coupled with tandem mass spectrometry are included. HPLC methods have been reported to include 0.6-26 min as the run times and 0.01 ng/mL to 25 µg/mL as detection limits. The most commonly used columns were C18 with various buffers as the mobile phases, along with various organic modifiers. The optimization of HPLC conditions has been discussed. It has been observed that the reported methods are quite satisfactory for the analyses of β-adrenergic blockers in biological samples. Future perspectives in the hyphenation of solid-phase microextraction-nano-liquid chromatography-tandem mass spectrometry have also been highlighted to achieve detections at nanogram and picogram levels. The present article is very useful for academicians, scientists, drug and pharmaceutical personnel and government regulatory authorities.

  20. Development and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma

    Directory of Open Access Journals (Sweden)

    Shahnaz Gauhar

    2009-03-01

    Full Text Available Objective(sDeveloping and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and MethodsA shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, pH 2.9 adjusted with KOH were used. The flow rate was 1 ml/min and the analyses performed using ultraviolet (UV detector at a wavelength of 275 nm using acetaminophen as an internal standard.ResultsThe developed method showed good resolution between pefloxacin and acetaminophen. It was selective to pefloxacin and able to resolve the drug peak from internal standard and from formulation excipients. The percentage of coefficient variation (CV of the retention times and peak areas of pefloxacin from the six consecutive injections were 0.566% and 0.989%, respectively. The results showed that the peak area responses are linear within the concentration range of 0.125 µg/ml-12 µg/ml (R2= 0.9987. The limits of detection (LOD and limits of quantitation (LOQ for pefloxacin were 0.03125 µg/ml and 0.125 µg/ml. The intra-day and inter-day variation, RSD were 0.376-0.9056 and 0.739-0.853 respectively; also, inter-day variation with relative standard deviation (RSD were 0.1465-0.821 in plasma. The accuracy results of 70%, 100%, and 130% drugs were 100.72%, 100.34%, and 100.09%, respectively.ConclusionThe method is linear, quantitative, reproducible and could be used as a more convenient, efficient and economical method for the trace analysis of drug in biological fluids, in raw material and tablets.

  1. Determination of boron in uranium and aluminium by high pressure liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Rao, Radhika M.; Aggarwal, S.K.

    2003-01-01

    Experiments were conducted for the determination of boron in U 3 O 8 powder and aluminium metal using dynamically modified reversed phase high pressure liquid chromatography (RP-HPLC) and using precolumn chromogenic agent viz. curcumin for complexing boron. The complex was separated from the excess of reagent and determined by HPLC. The boron curcumin complex (rosocyanin) was formed after extraction of boron with 2-ethyl-1,3-hexane diol (EHD). Linear calibration curves for boron amounts in the range of 0.02 μg to 0.5 μg were developed and used for the determination of boron in aluminium and uranium samples. (author)

  2. The effect of various S-alkylating agents on the chromatographic behavior of cysteine-containing peptides in reversed-phase chromatography.

    Science.gov (United States)

    Jiang, Xuehui; Shamshurin, Dmitry; Spicer, Vic; Krokhin, Oleg V

    2013-02-01

    We investigate the influence of various alkylation chemistries on the reversed phase (RP) HPLC behavior of Cys-containing peptides under the most popular RP-HPLC conditions used in proteomics: C18 phases with trifluoroacetic acid (TFA) or formic acid (FA) as the ion pairing modifiers, and separation at pH 10. Akylating agents studied are iodoacetamide (IAM), iodoacetic acid (IAA), 4-vinylpyridine (4-VP), acrylamide (AA) and methyl methanethiosulfonate (MMTS). These were compared against the retention of identical peptides without alkylation, i.e. free cysteines. The intrinsic hydrophobicity values of the Cys residue under formic acid conditions for these modifications were found to increase in the following order: 4-VPalkylated Cys using TFA eluent. Switching to a basic condition dramatically decreases the retention of free cysteine and IAA-alkylated analytes due to the ionization of side-chains. The opposite effect is observed for 4-VP, which become neutral at basic pHs. The careful measurement of the hydrophobic contributions for these residues is vital to the development of accurate peptide retention prediction models; the incorporation of these modifications into our Sequence Specific Retention Calculator model is presented. Copyright © 2013. Published by Elsevier B.V.

  3. HPLC-DAD-ESI/MS Identification of Light Harvesting and Light Screening Pigments in the Lake Sediments at Edmonson Point

    Directory of Open Access Journals (Sweden)

    Rita Giovannetti

    2013-01-01

    Full Text Available The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC with electrospray-mass spectrometry (ESI-MS detection and diode array detection (DAD has been used to identify light screening and light harvesting pigments. The results are discussed in terms of local environmental conditions.

  4. Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies

    Directory of Open Access Journals (Sweden)

    Bo Wei

    2008-01-01

    Full Text Available A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5 to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C 18 reversed phase column (4.6 x 150 mm, 3.5 µm, using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5 delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (λ excitation = 300 nm, λ emission = 418 nm. The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD and the limit of quantification (LOQ of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.

  5. Method development for determination of herbicides and insecticides in surface waters using solid-phase extraction and high performance liquid chromatography

    International Nuclear Information System (INIS)

    Lebre, Daniel Temponi

    2000-01-01

    Determination of low concentrations of pesticides in surface and ground waters requires high sensitivity analytical techniques. Solid-Phase Extraction (SPE) has been successfully employed to pre concentrate and extract pesticides compounds from water samples. High Performance Liquid Chromatography (HPLC) coupled with UV/Vis detector was used to separate and quantify the extracted compounds. In this work, samples of surface waters with known concentrations of herbicides (atrazine, simazine and trifluralin) and insecticides (aldicarb, carbofuran and carbaryl) were extracted by using SPE off-line technique. The compounds were separated and quantified by reverse phase HPLC with UV detection at 220 ηm. The extraction efficiency was compared between two columns filled with different materials: C 18 -bonded silica phase (500 mg) and copolymer styrenedivynilbenzene resin (250 mg). The results were evaluated as the percent recovery of compounds obtained using different solvents at different concentrations. The results showed that recovery of the analytes greater than 80 % were obtained in SPE columns filled with C 18 bonded silica phase with 6 mL of acetonitrile. Once the optimum conditions were chosen for simulate water samples, the method was validated through analytical and statistical procedures and applied for surface waters. The suitability of the method was verified for the studied compounds showing good sensitivity, i. e., concentrations within the range of 0.4 to 4.0 μgL -1 of pesticides could be quantified attending the limits proposed by official regulations. (author)

  6. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  7. Analysis of electrophoretic soil humic acids fractions by reversed-phase high performance liquid chromatography with on-line absorbance and fluorescence detection.

    Science.gov (United States)

    Trubetskoj, Oleg A; Richard, Claire; Guyot, Ghislain; Voyard, Guillaume; Trubetskaya, Olga E

    2012-06-22

    A combination of reversed-phase high performance liquid chromatography (RP HPLC) with on-line absorbance and fluorescence detection was used for analysis of chernozem soil humic acids (HAs) and their fractions A, B and C+D with different electrophoretic mobility (EM) and molecular size (MS). Samples were injected onto the column at the identical volume and absorbance. All chromatograms exhibit the resolution of seven peaks. The estimation of relative recovery of HAs and fractions from the reverse-phase column has been done. High MS fraction A, which possesses the low EM, is essentially more hydrophobic (73% of the fraction amount remained adsorbed on the column) and aliphatic than medium MS and EM fraction B (33% of the fraction amount remained adsorbed on the column). The most hydrophilic and aromatic properties belong to low MS fraction C+D, which possess the highest EM and practically was not adsorbed on the column. The hydrophobicity of the bulk HAs lies within the range of fractions hydrophobicity. The absorption spectra of bulk HAs, electrophoretic fractions A, B, C+D and corresponding RP HPLC peaks were featureless but had differences in the values of absorbance ratio at 300 and 400 nm (A3/A4). For fractions A and B this ratio gradually decreased from peak 1 to 7 (from 3.05 to 2.80 and 3.00 to 2.40, respectively). This trend was less pronounced in HAs and practically absent in fraction C+D, where ratio A3/A4 varied within a small range. The strong relationship between fluorescence properties, EM, MS, polarity and aliphaticity/aromaticity of HAs fractions was found. Humic and protein-like fluorescence had different polarity nature. The protein-like fluorescence is located in humic material which irreversibly adsorbed on the reverse-phase column and not subjected to RP HPLC characterization. The humic-like fluorescence at Ex/Em 270/450 nm is mostly located in the hydrophilic peak of low MS fraction C+D. Taking into account that high MS fraction A consisted

  8. Simultaneous determination of atorvastatin calcium and olmesartan medoxomil in a pharmaceutical formulation by reversed phase high-performance liquid chromatography, high-performance thin-layer chromatography, and UV spectrophotometric methods.

    Science.gov (United States)

    Soni, Hiral; Kothari, Charmy; Khatri, Deepak; Mehta, Priti

    2014-01-01

    Validated RP-HPLC, HPTLC, and UV spectrophotometric methods have been developed for the simultaneous determination of atorvastatin calcium (ATV) and olmesartan medoxomil (OLM) in a pharmaceutical formulation. The RP-HPLC separation was achieved on a Kromasil C18 column (250 x 4.6 mm, 5 microm particle size) using 0.01 M potassium dihydrogen o-phosphate (pH 4 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1.5 mL/min. Quantification was achieved by UV detection at 276 nm. The HPTLC separation was achieved on precoated silica gel 60F254 plates using chloroform-methanol-acetonitrile (4 + 2+ 4, v/v/v) mobile phase. Quantification was achieved with UV detection at 276 nm. The UV-Vis spectrophotometric method was based on the simultaneous equation method that involves measurement of absorbance at two wavelengths, i.e., 255 nm (lambda max of OLM) and 246.2 nm (lambda max of ATV) in methanol. All three methods were validated as per International Conference on Harmonization guidelines. The proposed methods were simple, precise, accurate, and applicable for the simultaneous determination of ATV and OLM in a marketed formulation. The results obtained by applying the proposed methods were statistically analyzed and were found satisfactory.

  9. Validation of an HPLC method for the simultaneous determination of eletriptan and UK 120.413

    Directory of Open Access Journals (Sweden)

    LJILJANA ZIVANOVIC

    2006-11-01

    Full Text Available Arapid and sensitive RPHPLCmethod was developed for the routine control analysis of eletriptan hydrobromide and its organic impurity UK 120.413 in Relpax® tablets. The chromatography was performed at 20 °Cusing a C18 XTerraTM (5 m, 150 × 4,6 mm column at a flow rate 1.0 ml/min. The drug and its impurity were detected at 225 nm. The mobile phase consisted of TEA (1 % – methanol (67.2:32.8 v/v, the pH of which was adjusted to 6.8 with 85 % orthophosphoric acid. Quantification was accomplished by the internal standard method. The developed RP HPLC method was validated by testing: accuracy, precision, repeatibility, specificity, detection limit, quantification limit, linearity, robustness and sensitivity. High linearity of the analytical procedure was confirmed over the concentration range of 0.05 – 1.00 mg/ml for eletriptan hydrobromide and from 0.10 – 1.50 µg/ml for UK 120.413, with correlation coefficients greater than r = 0.995. The low value of the RSD expressed the good repeatability and precision of the method. Experimental design and a response surface method were used to test robustness of the analytical procedure and to evaluate the effect of variation of the method parameters, namely the mobile phase composition, pH and temperature. They showed small deviations from the method setting. The good recovery and low RSD confirm the suitability of the proposed RP HPLC method for the routine determination of eletriptan hydrobromide and its impurity UK 120.413 in Relpax® tables.

  10. Methods and applications of HPLC-AMS (WBio 5)

    International Nuclear Information System (INIS)

    Bucholz, B A; Clifford, A J; Duecker, S R; Lin, Y; Vogel, J S

    1999-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a(sup 14)C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the(sup 14)C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the(sup 14)C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of(sup 14)C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected(sup 14)C activity and lt;0.17 Bq (4.5 pCi) on the HPLC column

  11. A size exclusion-reversed phase two dimensional-liquid chromatography methodology for stability and small molecule related species in antibody drug conjugates.

    Science.gov (United States)

    Li, Yi; Gu, Christine; Gruenhagen, Jason; Zhang, Kelly; Yehl, Peter; Chetwyn, Nik P; Medley, Colin D

    2015-05-08

    Antibody drug conjugates (ADCs) are complex therapeutic agents combining the specific targeting properties of antibodies and highly potent cytotoxic small molecule drugs to selectively eliminate tumor cells while limiting the toxicity to normal healthy tissues. One unique critical quality attribute of ADCs is the content of unconjugated small molecule drug present from either incomplete conjugation or degradation of the ADC. In this work, size exclusion chromatography (SEC) was coupled with reversed-phase (RP) HPLC in an online 2-dimensional chromatography format for identification and quantitation of unconjugated small molecule drugs and related small molecule impurities in ADC samples directly without sample preparation. The SEC method in the 1st dimension not only separated the small molecule impurities from the intact ADC, but also provided information about the size variants (monomer, dimer, aggregates, etc.) of the ADC. The small molecule peak from the SEC was trapped and sent to a RP-HPLC in the 2nd dimension to further separate and quantify the different small molecule impurities present in the ADC sample. This SEC-RP 2D-LC method demonstrated excellent precision (%RSDmolecule degradation products and aggregation of the conjugate were observed in the stability samples and the degradation pathways of the ADC were investigated. This 2D-LC method offers a powerful tool for ADC characterization and provides valuable information for conjugation and formulation development. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Quantitative determination of reserpine, ajmaline, and ajmalicine in Rauvolfia serpentina by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Srivastava, A; Tripathi, A K; Pandey, R; Verma, R K; Gupta, M M

    2006-10-01

    A sensitive and reproducible reversed-phase high-performance liquid chromatography (HPLC) method using photodiode array detection is established for the simultaneous quantitation of important root alkaloids of Rauvolfia serpentina, namely, reserpine, ajmaline, and ajmalicine. A Chromolith Performance RP-18e column (100 x 4.6-mm i.d.) and a binary gradient mobile phase composed of 0.01 M (pH 3.5) phosphate buffer (NaH(2)PO(4)) containing 0.5% glacial acetic acid and acetonitrile are used. Analysis is run at a flow rate of 1.0 mL/min with the detector operated at a wavelength of 254 nm. The calibration curves are linear over a concentration range of 1-20 microg/mL (r = 1.000) for all the alkaloids. The various other aspects of analysis (i.e., peak purity, similarity, recovery, and repeatability) are also validated. For the three components, the recoveries are found to be 98.27%, 97.03%, and 98.38%, respectively. The limits of detection are 6, 4, and 8 microg/mL for ajmaline, ajmalicine, and reserpine, respectively, and the limits of quantitation are 19, 12, and 23 microg/mL for ajmaline, ajmalicine, and reserpine, respectively. The developed method is simple, reproducible, and easy to operate. It is useful for the evaluation of R. serpentina.

  13. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    Science.gov (United States)

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  14. Pungency Quantitation of Hot Pepper Sauces Using HPLC

    Science.gov (United States)

    Betts, Thomas A.

    1999-02-01

    A class of compounds known as capsaicinoids are responsible for the "heat" of hot peppers. To determine the pungency of a particular pepper or pepper product, one may quantify the capsaicinoids and relate those concentrations to the perceived heat. The format of the laboratory described here allows students to collectively develop an HPLC method for the quantitation of the two predominant capsaicinoids (capsaicin and dihydrocapsaicin) in hot-pepper products. Each small group of students investigated one of the following aspects of the method: detector wavelength, mobile-phase composition, extraction of capsaicinoids, calibration, and quantitation. The format of the lab forced students to communicate and cooperate to develop this method. The resulting HPLC method involves extraction with acetonitrile followed by solid-phase extraction clean-up, an isocratic 80:20 methanol-water mobile phase, a 4.6 mm by 25 cm C-18 column, and UV absorbance detection at 284 nm. The method developed by the students was then applied to the quantitation of capsaicinoids in a variety of hot pepper sauces. Editor's Note on Hazards in our April 2000 issue addresses the above.

  15. Development and Validation of HPLC-PDA Assay method of Frangula emodin

    Directory of Open Access Journals (Sweden)

    Deborah Duca

    2016-03-01

    Full Text Available Frangula emodin, (1,3,8-trihydroxy-6-methyl-anthraquinone, is one of the anthraquinone derivatives found abundantly in the roots and bark of a number of plant families traditionally used to treat constipation and haemorrhoids. The present study describes the development and subsequent validation of a specific Assay HPLC method for emodin. The separation was achieved on a Waters Symmetry C18, 4.6 × 250 mm, 5 μm particle size, column at a temperature of 35 °C, with UV detection at 287 and 436 nm. An isocratic elution mode consisting of 0.1% formic acid and 0.01% trifluoroacetic acid as the aqueous mobile phase, and methanol was used. The method was successfully and statistically validated for linearity, range, precision, accuracy, specificity and solution stability.

  16. HPLC characterization of clinically used sup(99m)Tc bone agents. Relative tissue distribution of fractionated components in mice

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.E.; Richards, P.; Ford, L.A.; Benson, W.R.

    1982-01-01

    A study was undertaken to separate and characterize the components of clinically used (kit produced) 99m-Tc-Sn-MDP and 99m-Tc-Sn-EHDP preparations by high performance liquid chromatography (HPLC) using radioactivity detection mode. Tissue distribution studies of the HPLC fractionated species were carried out in mice in order to define the in vivo behavior of the individual components. Effect of many variables such as time, oxygen, pH, temperature, etc. on the above two systems was also studied in relation to the composition as determined by HPLC and changes, if any, in the biological behavior. The results demonstrate the unique capabilities of reverse phase HPLC for rapid and high resolution analysis of complex 99mTc radiopharmaceutical mixtures

  17. A Thermal Degradation (Thermolysis) Study of Rotenone Extracted from Derris elliptica Roots Using Reverse-Phase High Performance Liquid Chromatography (RP-HPLC)

    International Nuclear Information System (INIS)

    Saiful Irwan Zubairi; Mohamad Roji Sarmidi; Ramlan Abdul Aziz

    2015-01-01

    Bio-pesticides are becoming increasingly important as pest management tools in various cropping systems in the tropics essentially to remedy problems associated with the indiscriminate use of hard and non-environmental friendly inorganic pesticide. In these past few decades, many bio-pesticidal products, both microbial-based (bacteria, fungi, microsprodia, entomopathogenic nematodes and viruses) and plant-based botanicals (rotenone and azadiracthin) have been studied for their use against insect pests in the tropics. In this study, the effects of the concentration process with respect to the yield of rotenone (mg) and its concentration (mg/mL) are presented extensively. The raw plants were collected from Kota Johor Lama, Johor and sorted to obtain the roots and stems. Only the roots and stems were utilized as raw materials of the extraction process. The rotenone from roots and stems was extracted using the normal soaking extraction (NSE) at 28 to 30 degree Celsius with 95 % (v/v) of acetone as a solvent and the solvent-to-solid ratio of 10 mL/ g. The extraction was carried out for 24 h. Next, the liquid crude extract was concentrated using the rotary evaporator at 50 degree Celsius and 80 mbar of vacuum pressure to remove approximately 90 % of solvent. The fractions of the liquid crude extract were collected (15 min/ mL/ fraction), diluted (1/100 with acetone) and cleaned up (to remove any fine debris) prior to determination of rotenone content (mg) and concentration (mg/mL) by using the reverse-phase high performance liquid chromatography (RP-HPLC). Finally, the results showed that there was a significant effect of thermal degradation or dissipation of rotenone content at higher operating temperature (greater than 40 degree Celsius) with a rapid rotenone reduction for the first 15 min of exposure. The possibilities for better exploitation and identification of the effective operating parameters based on the above mentioned results will be perhaps discussed in the

  18. STABILITY-INDICATING RP-HPLC METHOD FOR SIMULTANEOUS ...

    African Journals Online (AJOL)

    B. S. Chandravanshi

    pharmacopoeia, a careful and thorough literature review also showed absence of any reversed phase LC .... cetostearyl alcohol, petroleum jelly) of the ointment and human serum. Synthetic ... acid/base hydrolysis and oxidation. Acid-stress ...

  19. [Determination of biphenyl ether herbicides in water using HPLC with cloud-point extraction].

    Science.gov (United States)

    He, Cheng-Yan; Li, Yuan-Qian; Wang, Shen-Jiao; Ouyang, Hua-Xue; Zheng, Bo

    2010-01-01

    To determine residues of multiple biphenyl ether herbicides simultaneously in water using high performance liquid chromatography (HPLC) with cloud-point extraction. The residues of eight biphenyl ether herbicides (including bentazone, fomesafen, acifluorfen, aclonifen, bifenox, fluoroglycofenethy, nitrofen, oxyfluorfen) in water samples were extracted with cloud-point extraction of Triton X-114. The analytes were separated and determined using reverse phase HPLC with ultraviolet detector at 300 nm. Optimized conditions for the pretreatment of water samples and the parameters of chromatographic separation applied. There was a good linear correlation between the concentration and the peak area of the analytes in the range of 0.05-2.00 mg/L (r = 0.9991-0.9998). Except bentazone, the spiked recoveries of the biphenyl ether herbicides in the water samples ranged from 80.1% to 100.9%, with relative standard deviations ranging from 2.70% to 6.40%. The detection limit of the method ranged from 0.10 microg/L to 0.50 microg/L. The proposed method is simple, rapid and sensitive, and can meet the requirements of determination of multiple biphenyl ether herbicides simultaneously in natural waters.

  20. Identification and quantitation of asparagine and citrulline using high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Bai, Cheng; Reilly, Charles C; Wood, Bruce W

    2007-03-28

    High-performance liquid chromatography (HPLC) analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates). Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (microMol ml(-1)/microMol ml(-1))], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh.) K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  1. Identification and Quantitation of Asparagine and Citrulline Using High-Performance Liquid Chromatography (HPLC

    Directory of Open Access Journals (Sweden)

    Cheng Bai

    2007-01-01

    Full Text Available High-performance liquid chromatography (HPLC analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates. Asparagine alone is eluted earlier than citrulline alone, but when both of them are present in biological samples they may co-elute. HPLC retention times for asparagine and citrulline were influenced by other ureides in the mixture. We found that at various asparagines and citrulline ratios [= 3:1, 1:1, and 1:3; corresponding to 75:25, 50:50, and 25:75 (μMol ml–1/μMol ml–1], the resulting peak exhibited different retention times. Adjustment of ureide ratios as internal standards enables peak identification and quantification. Both chemicals were quantified in xylem sap samples of pecan [Carya illinoinensis (Wangenh. K. Koch] trees. Analysis revealed that tree nickel nutrition status affects relative concentrations of Urea Cycle intermediates, asparagine and citrulline, present in sap. Consequently, we concluded that the HPLC methods are presented to enable qualitative and quantitative analysis of these metabolically important ureides.

  2. Simple and Selective HPLC-UV/Vis Bioanalytical Method to Determine Aluminum Phthalocyanine Chloride in Skin Permeation Studies

    Directory of Open Access Journals (Sweden)

    Thaiene Avila Reis

    2018-01-01

    Full Text Available Considering the feasibility of the aluminum phthalocyanine chloride (AlPcCl application in the topical photodynamic therapy of cutaneous tumors and the lack of HPLC methods capable of supporting skin permeation experiments using this compound, the aim of this study was to obtain a simple and selective chromatographic method for AlPcCl determination in skin matrices. A HPLC-UV/Vis method was developed using a normal-phase column operating at 30°C, an isocratic mobile phase of methanol : phosphoric acid (0.01 M at 1.5 mL/min, and detection at 670 nm. The method exhibited (i selectivity against various contaminants found in the different skin layers, (ii high drug extraction capacity from the hair follicle (>70% and remaining skin (>80%, and (iii low limits of detection and of quantification (0.03 and 0.09 μg/mL, resp.. The method was also linear in the range from 0.1 to 5.0 µg/mL (r = 0.9994 and demonstrated robustness with regard to experimental chromatographic parameters according to a factorial design. Lastly, the developed method was successfully tested in in vitro skin permeation studies of AlPcCl, proving its effectiveness in the development of pharmaceutical delivery systems containing this drug for topical photodynamic therapy of skin cancers.

  3. Principles of Developing Multi-Pesticide Methods Based on HPLC Determination

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    Principles for the development of multi-pesticide methods based on HPLC determination are outlined. Flow charts and block diagrams give guidance on how to proceed stepwise in the set-up of respective analytical methods. Detailed information is provided on what to take into consideration for setting up a pesticide formulation analysis method. HPLC variables like the types of column, solvents and their strength, pH value, eluent modifiers, column temperature, etc, and the influence on the separation and resolution of chromatographic peaks are discussed as well as the necessity and benefits of internal standardization. Examples of system suitability testing experiments are given for illustration. (author)

  4. Development and Validation of Stability Indicating HPTLC and HPLC Methods for Simultaneous Determination of Telmisartan and Atorvastatin in Their Formulations

    Directory of Open Access Journals (Sweden)

    Kaliappan Ilango

    2013-01-01

    Full Text Available The present study describes development and subsequent validation of stability indicating HPLC and HPTLC methods for simultaneous estimation of Telmisartan (TLM and Atorvastatin (ATV in their combined formulation. The proposed RP-HPLC method utilizes a Phenomenex Luna C18 column using acetonitrile: 0.025 M ammonium acetate (38 : 52%, v/v as mobile phase (pH 3.8, flow rate of 1.0 mL/min. Quantification was achieved with UV detection at 281 nm over concentration range of 12 to 72 μg/mL for TLM and 3 to 18 μg/mL for ATV respectively. In HPTLC, separations were performed on silica gel 60 F254 using toluene-methanol-ethyl acetate-acetic acid (5 : 1 : 1 : 0.3, v/v as mobile phase. The compact bands of TLM and ATV at 0.37 ± 0.02 and 0.63 ± 0.01 respectively were scanned at 279 nm. Linear regression analysis revealed linearity in the range of 40 to 240 ng/band for TLM and 10 to 60 ng/band for ATV respectively. For both the methods, dosage form was exposed to thermal, photolytic, acid, alkali and oxidative stress. The methods distinctly separated the drugs and degradation products even in actual samples. In conclusion, the proposed HPLC and HPTLC methods were appropriate for routine quantification of TLM and ATV in tablet formulation.

  5. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  6. [Comparative data regarding two HPLC methods for determination of isoniazid].

    Science.gov (United States)

    Gârbuleţ, Daniela; Spac, A F; Dorneanu, V

    2009-01-01

    For the determination of isoniazide (isonicotinic acid hydrazide - HIN) two different HPLC methods were developed and validated. Both experiments were performed using a Waters 2695 liquid chromatograph and a UV - Waters 2489 detector. The first method (I) used a Nucleosil 100-10 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of acetonitrile/10(-2) M oxalic acid (80/20) and a flow of 1.5 mL/ min; detection was done at 230 nm. The second method (II) used a Luna 100-5 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of methanol/acetate buffer, pH = 5.0 (20/ 80), a flow of 1 mL/min; detection was done at 270 nm. Both methods were validated, the correlation coefficients were 0.9998 (I) and 0.9999 (II), the detection limits were 0.6 microg/mL (I) and 0.055 microg/mL (II), the quantitation limits were 1.9 microg/mL (I) and 0.2 microg/ mL (II). There were also studied: the system precision (RSD = 0.1692% (I) and 0.2000% (II)), the method precision (RSD = 1.1844% (I) and 0.6170% (II)) and the intermediate precision (RSD = 1.8058% (I) and 0.5970% (II)). The accuracy was good, the calculated recoveries were 102.66% (I) and 101.36 (II). Both validated methods were applied for HIN determination from tablets with good and comparable results.

  7. A Simple HPLC Bioanalytical Method for the Determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, accurate, and precise high performance chromatography (HPLC) method with spectrophotometric detection for the determination of doxorubicin hydrochloride in rat plasma. Methods: Doxorubicin hydrochloride and daunorubicin hydrochloride (internal standard, IS) were separated on a C18 ...

  8. Diazonium modification of porous graphitic carbon with catechol and amide groups for hydrophilic interaction and attenuated reversed phase liquid chromatography.

    Science.gov (United States)

    Iverson, Chad D; Zhang, Ya; Lucy, Charles A

    2015-11-27

    Porous graphitic carbon (PGC) is an increasingly popular and attractive phase for HPLC on account of its chemical and thermal stability, and its unique separation mechanism. However, native PGC is strongly hydrophobic and in some instances excessively retentive. As part of our effort to build a library of hydrophilic covalently modified PGC phases, we functionalized PGC with catechol and amide groups by means of aryl diazonium chemistry to produce two new phases. Successful grafting was confirmed by X-ray photoelectron spectroscopy (XPS). Under HILIC conditions, the Catechol-PGC showed up to 5-fold increased retention relative to unmodified PGC and selectivity that differed from four other HILIC phases. Under reversed phase conditions, the Amide-PGC reduced the retentivity of PGC by almost 90%. The chromatographic performance of Catechol-PGC and Amide-PGC is demonstrated by separations of nucleobases, nucleosides, phenols, alkaline pharmaceuticals, and performance enhancing stimulants. These compounds had retention factors (k) ranging from 0.5 to 13. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Brief on -Hyphenated Methods of HPLC for Determining the Presence of Solutes.

    Directory of Open Access Journals (Sweden)

    Mohamad Taleuzzaman

    2017-02-01

    Full Text Available HPLC is the tool in liquid chromatography is unique because of particle size, smaller particle in the stationary phase, increase efficiency of a separation. However, if the particles are made smaller, capillary action increases and it becomes more difficult to drain the column under gravity. For quantitative analysis different types of detector is used in conjunction with HPLC which give precise and accurate result and it is apply according to the nature of the substance. Various types of detectors used in HPLC are mass spectrometry, infrared spectroscopy, visible spectroscopy, ultraviolet spectroscopy, fluorescence spectroscopy, nuclear magnetic resonance, conductivity measurement, and refractive index measurement. Each detector has its assets, limitations and sample types for which it is most effective. The recent development of the so-called hyphenated techniques has improved the ability to separate and identify multiple entities within a mixture.

  11. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    Science.gov (United States)

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  12. Doping reversed-phase media for improved peptide purification.

    Science.gov (United States)

    Khalaf, Rushd; Forrer, Nicola; Buffolino, Gianluca; Gétaz, David; Bernardi, Susanna; Butté, Alessandro; Morbidelli, Massimo

    2015-06-05

    The purification of therapeutic peptides is most often performed using one or more reversed phase chromatography steps. This ensures high purities while keeping the costs of purification under control. In this paper, a doped reversed phase chromatographic material is tested and compared to traditional reversed phase materials. The doping consists of adding limited amounts of ion exchange ligands to the surface of the material to achieve orthogonal separation and increase the non-hydrophobic interactions with the surface. These ionic groups can either be attractive (opposite charge), or repulsive (same charge) to the peptide. The benefit of this new doped reversed phase material is shown through increases in selectivity in diluted conditions and yield and productivity in overloaded (i.e. industrial) conditions. It is the conjectured that all performance characteristics should increase using repulsive doping groups, whereas these characteristics should decrease when using attractive doping groups. This conjecture is shown to be true through several examples, including purifications of industrially relevant peptide crudes, in industrially relevant conditions. Moreover, the effect of ionic strength and organic modifier concentration was explored and shown to be in line with the expected behavior. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. A rapid and efficient preparation of [{sup 123}I]radiopharmaceuticals using a small HPLC Rocket[reg] column

    Energy Technology Data Exchange (ETDEWEB)

    Katsifis, Andrew [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia)]. E-mail: akx@ansto.gov.au; Papazian, Vahan [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia); Jackson, Timothy [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia); Loc' h, Christian [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia)

    2006-01-01

    A simplified method for the rapid and efficient preparation of [{sup 123}I]radiopharmaceuticals is described. Three radiopharmaceuticals, [{sup 123}I]{beta}-CIT, [{sup 123}I]MIBG and [{sup 123}I]clioquinol, were synthesised and purified as model compounds. The radiotracers were labelled with iodine-123 using electrophilic oxidative conditions and purified by a compact semi-preparative reverse phase column (C-18, 3 {mu}m, 7x53 mm, Alltima Rocket[reg, Alltech] using aqueous-ethanol as HPLC solvents that were directly used for radiopharmaceutical formulation. The radiochemical purity of the radioiodinated tracers as assessed by analytical HPLC was higher than 99% with specific activity higher than 3 GBq/nmol. The total preparation time of a radiotracer ranged from 40 to 60 min and, starting from 3.7 GBq of iodine-123, more than 2.5 GBq of formulated radiopharmaceuticals were available for clinical investigations.

  14. Validation of an HPLC method for determination of chemical purity of [{sup 18}F]fluoromisonidazole ([{sup 18}F]FMISO)

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Natalia C.E.S.; Oliveira, Mércia L.; Lima, Fernando R.A., E-mail: nataliafleming@hotmail.com, E-mail: mercial@cnen.gov.br, E-mail: falima@cnen.gov.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Silveira, Marina B.; Ferreira, Soraya Z.; Silva, Juliana B., E-mail: mbs@cdtn.br, E-mail: zandims@cdtn.br, E-mail: silvajb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    [{sup 18}F]Fluoromisonidazole ([{sup 18}F]FMISO) is a nitroimidazole derivative labelled with fluorine-18 that selectively binds to hypoxic cells. It has been shown to be a suitable PET tracer for imaging hypoxia in tumors as well as in noncancerous tissues. [{sup 18}F]FMISO was prepared using a TRACERlabMX{sub FDG}® module (GE) with cassettes, software sequence and reagents kits from ABX. In this work, we aimed to develop and to validate a new high performance liquid chromatography (HPLC) method for determination of chemical purity of [{sup 18}F]FMISO. Analyses were performed with an Agilent chromatograph equipped with radioactivity and UV detectors. [{sup 18}F]FMISO and impurities were separated on a C18 column by gradient elution with water and acetonitrile. Selectivity, linearity, detection limit (DL), quantification limit (LQ), precision, accuracy and robustness were assessed to demonstrate that the HPLC method is adequate for its intended purpose. The HPLC method showed a good precision, as all RSD values were lower than 5%. Robustness was evaluated considering a variation on parameters such mobile phase gradient and flow rate. Results evidenced that the HPLC method is validated and is suitable for radiochemical purity evaluation of [{sup 18}F]FMISO, considering operational conditions of our laboratory. As an extension of this work, other analytical methods used for [{sup 18}F]FMISO quality control should be evaluated, in compliance with good manufacture practice. (author)

  15. Sensitive detectors in HPLC

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Detection of sample components in HPLC is difficult for many reasons; the key difficulty is the mobile phase which usually has properties similar to the solute. A variety of detectors have been developed for use in HPLC based on one of the above approaches; however, the search is still continuing for an ideal or universal detector. A universal detector should have the following characteristics: (1) responds to all solutes or has predictable specificity; (2) high detectability and the same predictable response; (3) fast response; (4) wide range of linearity; (5) unaffected by changes in temperature and mobile-phase flow; (6) responds independently of the mobile phase; (7) makes no contribution to extracolumn band broadening; (8) reliable and convenient to use; (9) nondestructive to the solute; (10) provides qualitative information on the detected peak. Unfortunately, no available HPLC detector possesses all these properties. 145 refs

  16. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  17. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    Md. Sarowar Jahan

    2014-01-01

    Full Text Available A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH. For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8 and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS, 150 × 4.6 mm, 5 μm, Phenomenex Inc. column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient ( R 2 values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient ( R 2 > 0.995. The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%. Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH, while paracetamol showed <20% degradation in oxidation and basic condition.

  18. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    Science.gov (United States)

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed degradation in oxidation and basic condition.

  19. HPLC-UV Polyphenolic Profiles in the Classification of Olive Oils and Other Vegetable Oils via Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Mireia Farrés-Cebrián

    2016-12-01

    Full Text Available High performance liquid chromatography-ultraviolet (HPLC-UV was applied to the analysis and characterization of olive oils and other vegetable oils. A chromatographic separation on a Zorbax Eclipse XDB-C8 reversed-phase column was proposed under gradient elution, employing 0.1% formic acid aqueous solution and methanol as mobile phase, for the determination of 14 polyphenols and phenolic acids, allowing us to obtain compositional profiles in less than 20 min. Acceptable sensitivity (limit of detection (LOD values down to 80 µg/L in the best of cases, linearity (r2 higher than 0.986, good run-to-run and day-to-day precisions (relative standard deviation (RSD values lower than 11.5%, and method trueness (relative errors lower than 6.8% were obtained. The proposed HPLC-UV method was then applied to the analysis of 72 oil samples (47 olive oils and 27 vegetable oils including sunflower, soy, corn, and mixtures of them. Analytes were recovered using a liquid–liquid extraction method employing ethanol:water 70:30 (v/v solution and hexane as extracting and defatting solvents, respectively. HPLC-UV polyphenolic profiles using peak areas were then analysed by principal component analysis (PCA to extract information from the most significant data contributing to the characterization and classification of olive oils against other vegetable oils, as well as among Arbequina and Picual olive oil varieties. PCA results showed a noticeable difference between olive oils and the other classes. In addition, a reasonable discrimination of olive oils as a function of fruit varieties was also encountered.

  20. A rapid solid-phase extraction method for measurement of non-metabolised peripheral benzodiazepine receptor ligands, [18F]PBR102 and [18F]PBR111, in rat and primate plasma

    International Nuclear Information System (INIS)

    Katsifis, Andrew; Loc'h, Christian; Henderson, David; Bourdier, Thomas; Pham, Tien; Greguric, Ivan; Lam, Peter; Callaghan, Paul; Mattner, Filomena; Eberl, Stefan; Fulham, Michael

    2011-01-01

    Objectives: To develop a rapid and reliable method for estimating non-metabolised PBR ligands fluoroethoxy ([ 18 F]PBR102)- and fluoropropoxy ([ 18 F]PBR111)-substituted 2-(6-chloro-2-phenyl)imidazo[1,2-a]pyridine-3-yl)-N,N-diethylacetamides in plasma. Methods: Rats and baboons were imaged with PET up to 2 h postinjection of [ 18 F]PBR102 and [ 18 F]PBR111 under baseline conditions, after pre-blocking or displacement with PK11195. Arterial plasma samples were directly analysed by reverse-phase solid-phase extraction (RP-SPE) and RP-HPLC and by normal-phase TLC. SPE cartridges were successively washed with acetonitrile/water mixtures. SPE eluant radioactivity was measured in a γ-counter to determine the parent compound fraction and then analysed by HPLC and TLC for validation. Results: In SPE, hydrophilic and lipophilic radiolabelled metabolites were eluted in water and 20% acetonitrile/water. All non-metabolised [ 18 F]PBR102 and [ 18 F]PBR111 were in SPE acetonitrile fraction as confirmed by HPLC and TLC analysis. Unchanged (%) [ 18 F]PBR102 and [ 18 F]PBR111 from SPE analysis in rat and baboon plasma agreed with those from HPLC and TLC analysis. In rats and baboons, the fraction of unchanged tracer followed a bi-exponential decrease, with half-lives of 7 to 10 min for the fast component and >80 min for the slow component for both tracers. Conclusions: Direct plasma SPE analysis of [ 18 F]PBR102 and [ 18 F]PBR111 can reliably estimate parent compound fraction. SPE was superior to HPLC for samples with low activity; it allows rapid and accurate metabolite analysis of a large number of plasma samples for improved estimation of metabolite-corrected input function during quantitative PET imaging studies.

  1. Rapid HPLC-MS method for the simultaneous determination of tea catechins and folates.

    Science.gov (United States)

    Araya-Farias, Monica; Gaudreau, Alain; Rozoy, Elodie; Bazinet, Laurent

    2014-05-14

    An effective and rapid HPLC-MS method for the simultaneous separation of the eight most abundant tea catechins, gallic acid, and caffeine was developed. These compounds were rapidly separated within 9 min by a linear gradient elution using a Zorbax SB-C18 packed with sub 2 μm particles. This methodology did not require preparative and semipreparative HPLC steps. In fact, diluted tea samples can be easily analyzed using HPLC-MS as described in this study. The use of mass spectrometry detection for quantification of catechins ensured a higher specificity of the method. The percent relative standard deviation was generally lower than 4 and 7% for most of the compounds tested in tea drinks and tea extracts, respectively. Furthermore, the method provided excellent resolution for folate determination alone or in combination with catechins. To date, no HPLC method able to discriminate catechins and folates in a quick analysis has been reported in the literature.

  2. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  3. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    Science.gov (United States)

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  4. Determination of modafinil in plasma and urine by reversed phase high-performance liquid-chromatography.

    Science.gov (United States)

    Schwertner, Harvey A; Kong, Suk Bin

    2005-03-09

    Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.

  5. [Application of HPLC-UV method for aripiprazole determination in serum].

    Science.gov (United States)

    Synowiec, Anna; Gomółka, Ewa; Zyss, Tomasz; Zieba, Andrzej; Florek, Ewa; Piekoszewski, Wojciech

    2012-01-01

    Aripiprazole is a new drug applied in schizophrenia treatment. There are not strict indications for aripiprazole therapeutic drug monitoring. Despite, serum aripiprazole measuring would help control the drug doses effectiveness. The drug monitoring can eliminate overdosing, adverse effects and let control proper drug ingestion. The aim of the paper was to develop a simple method for aripiprazole determination in serum for therapeutic drug monitoring. High performance liquid chromatography with spectrophotometric detection (HPLC-UV) was used. Resolution was performed on LC-8 column; moving phase was solution 0,025M trimethylammonium buffer: acetonitrile (62:38). Isocratic flow was 1,2 ml/min; internal standard (IS) was promazine; monitored wavelength was lambda=214 nm. The validation parameters were: limits of linearity (LOL) 100-800 ng/ml, limit of detection (LOD) 10 ng/ml, limit of quantity (LOQ) 100 ng/ml. Coefficient of variation (CV) describing accuracy and precision didn't cross 10%. The method was useful for therapeutic drug monitoring in serum of patients treated with aripiprazole.

  6. Development and validation of a stability-indicating RP-HPLC method for assay of betamethasone and estimation of its related compounds.

    Science.gov (United States)

    Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M

    2010-02-05

    Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.

  7. Development of HPLC and UV spectrophotometric methods for the determination of ascorbic acid using hydroxypropyl-β-cyclodextrin and triethanolamine as photostabilizing agents

    International Nuclear Information System (INIS)

    Garnero, Claudia; Longhi, Marcela

    2010-01-01

    In this study, the effect of complex formation with triethanolamine (TEA) alone and in combination with hydroxypropyl-β-cyclodextrin (HP-β-CD) on the photostability of ascorbic acid was evaluated for exposure to artificial and diffuse daylight. The first-order rate constants for the photodegradation reactions were determined. The data obtained showed that these complexes strongly reduced the photodegradation process with an 11- and 35-fold increase in the photostability of ascorbic acid, depending of the ligand concentration and the irradiation source. The multicomponent complex gave a significantly better stabilization for exposure to light than TEA alone. Due to the fact that the complexation extended the exposure of ascorbic acid to light (without molecular changes), UV spectrophotometric and reversed phase high performance liquid chromatographic (HPLC) methods were developed for the quantitative determination of the vitamin in pure form and in pharmaceutical preparations. These methods were statistically validated, all the validation parameters were found to be within the acceptance range. These results demonstrate that the proposed methods are suitable for the quality control of ascorbic acid, providing simple, rapid, precise, accurate and convenient approaches for routine analysis of bulk drug and pharmaceutical formulations.

  8. Identification and Quantitation of Asparagine and Citrulline Using High-Performance Liquid Chromatography (HPLC)

    OpenAIRE

    Bai, Cheng; Reilly, Charles C.; Wood, Bruce W.

    2007-01-01

    High-performance liquid chromatography (HPLC) analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates). Asparagine alone is eluted earlier than citrulline alone, but when both of them...

  9. HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

    Directory of Open Access Journals (Sweden)

    Lee Fung Ang

    2014-12-01

    Full Text Available Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v (pH 2.6 at a flow rate of 1.3 mL/minutes, a column temperature of 35°C, and ultraviolet (UV detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of 0.00488 ─ 200 μg/mL, 0.625 ─ 320 μg/mL, 0.07813 ─ 320 μg/mL and 0.03906 ─ 320 μg/mL, respectively. The limits of detection and quantification, respectively, were 0.00488 and 0.03906 μg/mL for quercetin, 0.62500 and 2.50000 μg/mL for bisdemethoxycurcumin, 0.07813 and 0.31250 μg/mL for demethoxycurcumin, and 0.03906 and 0.07813 μg/mL for curcumin. The percent relative intra day standard deviation (% RSD values were 0.432 ─ 0.806 μg/mL, 0.576 ─ 0.723 μg/ mL, 0.635 ─ 0.752 μg/mL and 0.655 ─ 0.732 μg/mL for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were 0.323 ─ 0.968 μg/mL, 0.805 ─ 0.854 μg/mL, 0.078 ─ 0.844 μg/mL and 0.275 ─ 0.829 μg/mL, respectively. The intra day accuracies were 99.589% ─ 100.821%, 98.588% ─ 101.084%, 9.289% ─ 100.88%, and 98.292% ─ 101.022% for quercetin, bisdemethoxycurcumin

  10. Quantitative analysis of the major constituents of St John's wort with HPLC-ESI-MS.

    Science.gov (United States)

    Chandrasekera, Dhammitha H; Welham, Kevin J; Ashton, David; Middleton, Richard; Heinrich, Michael

    2005-12-01

    A method was developed to profile the major constituents of St John's wort extracts using high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS). The objective was to simultaneously separate, identify and quantify hyperforin, hypericin, pseudohypericin, rutin, hyperoside, isoquercetrin, quercitrin and chlorogenic acid using HPLC-MS. Quantification was performed using an external standardisation method with reference standards. The method consisted of two protocols: one for the analysis of flavonoids and glycosides and the other for the analysis of the more lipophilic hypericins and hyperforin. Both protocols used a reverse phase Luna phenyl hexyl column. The separation of the flavonoids and glycosides was achieved within 35 min and that of the hypericins and hyperforin within 9 min. The linear response range in ESI-MS was established for each compound and all had linear regression coefficient values greater than 0.97. Both protocols proved to be very specific for the constituents analysed. MS analysis showed no other signals within the analyte peaks. The method was robust and applicable to alcoholic tinctures, tablet/capsule extracts in various solvents and herb extracts. The method was applied to evaluate the phytopharmaceutical quality of St John's wort preparations available in the UK in order to test the method and investigate if they contain at least the main constituents and at what concentrations.

  11. Role of Reversible Phase Transformation for Strong Piezoelectric Performance at the Morphotropic Phase Boundary

    Science.gov (United States)

    Liu, Hui; Chen, Jun; Huang, Houbing; Fan, Longlong; Ren, Yang; Pan, Zhao; Deng, Jinxia; Chen, Long-Qing; Xing, Xianran

    2018-01-01

    A functional material with coexisting energetically equivalent phases often exhibits extraordinary properties such as piezoelectricity, ferromagnetism, and ferroelasticity, which is simultaneously accompanied by field-driven reversible phase transformation. The study on the interplay between such phase transformation and the performance is of great importance. Here, we have experimentally revealed the important role of field-driven reversible phase transformation in achieving enhanced electromechanical properties using in situ high-energy synchrotron x-ray diffraction combined with 2D geometry scattering technology, which can establish a comprehensive picture of piezoelectric-related microstructural evolution. High-throughput experiments on various Pb /Bi -based perovskite piezoelectric systems suggest that reversible phase transformation can be triggered by an electric field at the morphotropic phase boundary and the piezoelectric performance is highly related to the tendency of electric-field-driven phase transformation. A strong tendency of phase transformation driven by an electric field generates peak piezoelectric response. Further, phase-field modeling reveals that the polarization alignment and the piezoelectric response can be much enhanced by the electric-field-driven phase transformation. The proposed mechanism will be helpful to design and optimize the new piezoelectrics, ferromagnetics, or other related functional materials.

  12. OPTIMIZATION AND VALIDATION OF HPLC METHOD FOR TETRAMETHRIN DETERMINATION IN HUMAN SHAMPOO FORMULATION.

    Science.gov (United States)

    Zeric Stosic, Marina Z; Jaksic, Sandra M; Stojanov, Igor M; Apic, Jelena B; Ratajac, Radomir D

    2016-11-01

    High-performance liquid chromatography (HPLC) method with diode array detection (DAD) were optimized and validated for separation and determination of tetramethrin in an antiparasitic human shampoo. In order to optimize separation conditions, two different columns, different column oven temperatures, as well as mobile phase composition and ratio, were tested. Best separation was achieved on the Supelcosil TM LC-18- DB column (4.6 x 250 mm), particle size 5 jim, with mobile phase methanol : water (78 : 22, v/v) at a flow rate of 0.8 mL/min and at temperature of 30⁰C. The detection wavelength of the detector was set at 220 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity [r2 = 0.9997]. Accuracy of the method defined as a mean recovery of tetramethrin from shampoo matrix was 100.09%. The advantages of this method are that it can easily be used for the routine analysis of drug tetramethrin in pharmaceutical formulas and in all pharmaceutical researches involving tetramethrin.

  13. Development and validation of an HPLC-FLD method for milbemectin quantification in dog plasma.

    Science.gov (United States)

    Xu, Qianqian; Xiang, Wensheng; Li, Jichang; Liu, Yong; Yu, Xiaolei; Zhang, Yaoteng; Qu, Mingli

    2010-07-15

    Milbemectin is a widely used veterinary antiparasitic agent. A high-performance liquid chromatography with fluorescent detection (HPLC-FLD) method is described for the determination of milbemectin in dog plasma. The derivative procedure included mixing 1-methylimizole [MI, MI-ACN (1:1, v/v), 100 microL], trifluoroacetic anhydride [TFAA, TFAA-ACN (1:2, v/v), 150 microL] with a subsequent incubation for 3s at the room temperature to obtain a fluorescent derivative, which is reproducible in different blood samples and the derivatives proved to be stable for at least 80 h at room temperature. HPLC method was developed on C18 column with FLD detection at an excitation wavelength of 365 nm and emission wavelength of 475 nm, with the mobile phase consisting of methanol and water in the ratio of 98:2 (v/v). The assay lower limit of quantification was 1 ng/mL. The calibration curve was linear over concentration range of 1-200 ng/mL. The intra- and inter-day accuracy was >94% and precision expressed as % coefficient of variation was <5%. This method is specific, simple, accurate, precise and easily adaptable to measure milbemycin in blood of other animals. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.

  14. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms

    OpenAIRE

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2012-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. ...

  15. Validated HPLC method for identification and quantification of p-hydroxy benzoic acid and agnuside in Vitex negundo and Vitex trifolia

    Directory of Open Access Journals (Sweden)

    Sonal Shah

    2013-12-01

    Full Text Available A high performance liquid chromatography coupled with photodiode array detection method was developed for the identification and quantification of p-hydroxy benzoic acid and agnuside in the extracts of Vitex negundo and Vitex trifolia. The separation was achieved using acetonitrile and O-phosphoric acid–water (0.5%, v/v as the mobile phase in an isocratic elution mode. Mean retention times of standard p-hydroxy benzoic acid and agnuside were 6.14 and 11.90 min respectively. The developed method was validated as per the ICH guidelines for limit of detection, limit of quantification, linearity, accuracy and precision. Good linearity (r2≥0.999 was observed for both the compounds in wide concentration range. Relative standard deviation values for intra-day and inter-day precision studies were less than 2%. The analytical recoveries of p-hydroxy benzoic acid and agnuside by the developed HPLC method were 93.07% and 106.11% respectively. Two compounds were identified and quantified in leaves and bar extracts of V. negundo and V. trifolia using the developed HPLC method. Keywords: Vitex negundo, Vitex trifolia, HPLC-PDA, p-Hydroxy benzoic acid, Agnuside

  16. OPTIMIZATION OF A HPLC ANALYSIS METHOD FOR TAURINE AND CAFFEINE IN ENERGY DRINKS

    Directory of Open Access Journals (Sweden)

    RALUCA-IOANA [CHIRITA] TAMPU

    2018-03-01

    Full Text Available This paper presents the optimization of a rapid, inexpensive, reliable and selective isocratic high performance liquid chromatographic (HPLC method for the simultaneous determination of caffeine and taurine in energy drinks with two common detectors in series: evaporating light scattering detector (ELSD and an ultraviolet (UV detector. Satisfactory analysis results were obtained on an Astec apHera NH2 column using methanol/water (30:70 v/v as mobile phase. The optimized method was used for the analysis of commercial energy drinks containing large amounts of carbohydrates (100 g·L-1 and considerably lower amounts of taurine and caffeine (4 and 0.6 g·L-1, respectively. The advantages of this method consist of its lack of preliminary samples treatment and also the fact that basic LC instrumentation was employed.

  17. Development of a two-dimensional high-performance liquid chromatography system coupled with on-line reduction as a new efficient analytical method of 3-nitrobenzanthrone, a potential human carcinogen.

    Science.gov (United States)

    Hasei, Tomohiro; Nakanishi, Haruka; Toda, Yumiko; Watanabe, Tetsushi

    2012-08-31

    3-Nitrobenzanthrone (3-NBA) is an extremely strong mutagen and carcinogen in rats inducing squamous cell carcinoma and adenocarcinoma. We developed a new sensitive analytical method, a two-dimensional HPLC system coupled with on-line reduction, to quantify non-fluorescent 3-NBA as fluorescent 3-aminobenzanthrone (3-ABA). The two-dimensional HPLC system consisted of reversed-phase HPLC and normal-phase HPLC, which were connected with a switch valve. 3-NBA was purified by reversed-phase HPLC and reduced to 3-ABA with a catalyst column, packed with alumina coated with platinum, in ethanol. An alcoholic solvent is necessary for reduction of 3-NBA, but 3-ABA is not fluorescent in the alcoholic solvent. Therefore, 3-ABA was separated from alcohol and impurities by normal-phase HPLC and detected with a fluorescence detector. Extracts from surface soil, airborne particles, classified airborne particles, and incinerator dust were applied to the two-dimensional HPLC system after clean-up with a silica gel column. 3-NBA, detected as 3-ABA, in the extracts was found as a single peak on the chromatograms without any interfering peaks. 3-NBA was detected in 4 incinerator dust samples (n=5). When classified airborne particles, that is, those 7.0 μm in size, were applied to the two-dimensional HPLC system after purified using a silica gel column, 3-NBA was detected in those particles with particle sizes NBA in airborne particles and the detection of 3-NBA in incinerator dust. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Comparison of the phenolic composition of fruit juices by single step gradient HPLC analysis of multiple components versus multiple chromatographic runs optimised for individual families.

    Science.gov (United States)

    Bremner, P D; Blacklock, C J; Paganga, G; Mullen, W; Rice-Evans, C A; Crozier, A

    2000-06-01

    After minimal sample preparation, two different HPLC methodologies, one based on a single gradient reversed-phase HPLC step, the other on multiple HPLC runs each optimised for specific components, were used to investigate the composition of flavonoids and phenolic acids in apple and tomato juices. The principal components in apple juice were identified as chlorogenic acid, phloridzin, caffeic acid and p-coumaric acid. Tomato juice was found to contain chlorogenic acid, caffeic acid, p-coumaric acid, naringenin and rutin. The quantitative estimates of the levels of these compounds, obtained with the two HPLC procedures, were very similar, demonstrating that either method can be used to analyse accurately the phenolic components of apple and tomato juices. Chlorogenic acid in tomato juice was the only component not fully resolved in the single run study and the multiple run analysis prior to enzyme treatment. The single run system of analysis is recommended for the initial investigation of plant phenolics and the multiple run approach for analyses where chromatographic resolution requires improvement.

  19. A novel evaluation method for extrapolated retention factor in determination of n-octanol/water partition coefficient of halogenated organic pollutants by reversed-phase high performance liquid chromatography.

    Science.gov (United States)

    Han, Shu-ying; Liang, Chao; Qiao, Jun-qin; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan

    2012-02-03

    The retention factor corresponding to pure water in reversed-phase high performance liquid chromatography (RP-HPLC), k(w), was commonly obtained by extrapolation of retention factor (k) in a mixture of organic modifier and water as mobile phase in tedious experiments. In this paper, a relationship between logk(w) and logk for directly determining k(w) has been proposed for the first time. With a satisfactory validation, the approach was confirmed to enable easy and accurate evaluation of k(w) for compounds in question with similar structure to model compounds. Eight PCB congeners with different degree of chlorination were selected as a training set for modeling the logk(w)-logk correlation on both silica-based C(8) and C(18) stationary phases to evaluate logk(w) of sample compounds including seven PCB, six PBB and eight PBDE congeners. These eight model PCBs were subsequently combined with seven structure-similar benzene derivatives possessing reliable experimental K(ow) values as a whole training set for logK(ow)-logk(w) regressions on the two stationary phases. Consequently, the evaluated logk(w) values of sample compounds were used to determine their logK(ow) by the derived logK(ow)-logk(w) models. The logK(ow) values obtained by these evaluated logk(w) were well comparable with those obtained by experimental-extrapolated logk(w), demonstrating that the proposed method for logk(w) evaluation in this present study could be an effective means in lipophilicity study of environmental contaminants with numerous congeners. As a result, logK(ow) data of many PCBs, PBBs and PBDEs could be offered. These contaminants are considered to widely exist in the environment, but there have been no reliable experimental K(ow) data available yet. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Intra-specific genetic relationship analyses of Elaeagnus angustifolia based on RP-HPLC biochemical markers

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Elaeagnus angustifolia Linn. has various ecological, medicinal and economical uses. An approach was established using RP-HPLC (reversed-phase high-performance liquid chromatography) to classify and analyse the intra-specific genetic relationships of seventeen populations of E. angustifolia, collected from the Xinjiang areas of China. Chromatograms of alcohol-soluble proteins produced by seventeen populations ofE. angustifolia, were compared. Each chromatogram of alcohol-soluble proteins came from a single seed of one wild plant only. The results showed that when using a Waters Delta Pak. C18, 5 μm particle size reversed phase column (150 mm×3.9 mm), a linear gradient of 25%~60% solvent B with flow rate of 1 ml/min and run time of 67 min, the chromatography yielded optimum separation ofE. angustifolia alcohol-soluble proteins. Representative peaks in each population were chosen according to peak area and occurrence in every seed. The converted data on the elution peaks of each population were different and could be used to represent those populations. GSC (genetic similarity coefficients) of 41% to 62% showed a medium degree of genetic diversity among the populations in these eco-areas. Cluster analysis showed that the seventeen populations ofE. angustifolia could be divided into six clusters at the GSC=0.535 level and indicated the general and unique biochemical markers of these clusters. We suggest that E. angustifolia distribution in these eco-areas could be classified into six variable species. RP-HPLC was shown to be a rapid, repeatable and reliable method for E. angustifolia classification and identification and for analysis of genetic diversity.

  1. HPLC method for simultaneous quantitative detection of quercetin and curcuminoids in traditional chinese medicines.

    Science.gov (United States)

    Ang, Lee Fung; Yam, Mun Fei; Fung, Yvonne Tan Tze; Kiang, Peh Kok; Darwin, Yusrida

    2014-12-01

    Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of 35°C, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of 0.00488 ─ 200 μg/mL, 0.625 ─ 320 μg/mL, 0.07813 ─ 320 μg/mL and 0.03906 ─ 320 μg/mL, respectively. The limits of detection and quantification, respectively, were 0.00488 and 0.03906 μg/mL for quercetin, 0.62500 and 2.50000 μg/mL for bisdemethoxycurcumin, 0.07813 and 0.31250 μg/mL for demethoxycurcumin, and 0.03906 and 0.07813 μg/mL for curcumin. The percent relative intra day standard deviation (% RSD) values were 0.432 ─ 0.806 μg/mL, 0.576 ─ 0.723 μg/mL, 0.635 ─ 0.752 μg/mL and 0.655 ─ 0.732 μg/mL for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were 0.323 ─ 0.968 μg/mL, 0.805 ─ 0.854 μg/mL, 0.078 ─ 0.844 μg/mL and 0.275 ─ 0.829 μg/mL, respectively. The intra day accuracies were 99.589% ─ 100.821%, 98.588% ─ 101.084%, 9.289% ─ 100.88%, and 98.292% ─ 101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the

  2. The use of HPLC in the control of Neem commercial products quality: reproduction of the insecticide action

    International Nuclear Information System (INIS)

    Forim, Moacir Rossi; Matos, Andreia Pereira; Silva, Maria Fatima das Gracas Fernandes da; Cass, Quezia Bezerra; Vieira, Paulo Cezar; Fernandes, Joao Batista

    2010-01-01

    The Neem tree, Azadirachta indica, provides many useful compounds that are used as pesticides. However, the efficiency in field of products like neem oil can be committed because they have not been observed reproductive content of secondary metabolic like azadirachtin. Based on reverse-phase high-performance liquid chromatography (HPLC) a new method was developed to permit the rapid quantitative analysis of azadirachtin from seeds, extracts and oil of Neem. In the present study it was evaluated the azadirachtin quantitative variation among various Neem's extracts and seeds showing the importance of quality control for reproduction of the insecticide efficiency, using S. frugiperda as target insect. (author)

  3. Quantitative analysis of d,1-HMPAO and its freeze-dried kit with HPLC

    International Nuclear Information System (INIS)

    Chen Suzhen

    1993-05-01

    A quantitative analysis method, which uses RP-HPLC (reversed phase-high performance liquid chromatography), has been established to determine the stereoisomeric purity of HMPAO and d,1-HMPAO content for d,l-HMPAO freeze-dried kit. An opitmal mobile phase is selected for obtaining chromatographic parameters that are better than those published in the references. The theoretical tray height is less than 0.06 mm. At the flowrate of 1 ml/min the total separation time is 5.5. The resolution is greater than 5. The detectable limits of meso-HMPAO and d,l-HMPAO are 1 x 10 -8 g and 5 x 10 -7 g respectively. The precision is 5% and the additional recovery is 94% ∼ 107%. This method has many advantages such as accuracy, simplicity, rapidity and stability, and it is suitable for routine inspection. It has been successfully used to determine the HMPAO stereoisomer and d,1-HMPAO of freeze-dried kit produced by China Institute of Atomic Energy and same products imported from Amersham Company of United Kingdom

  4. Multi-Analyte Separation Methods for HPLC Determination of the Active Ingredients of Pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Virtics, I.; Korsós, I.; Homoki, E.; Lantos, J. [Plant Protection and Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The practical quality control of selected pesticides, such as carbamates, organophosphorous compounds, phthalimides, pyrethroids, with HPLC is described. Detailed descriptions are given of materials and methods used, including sample preparation and HPLC operating conditions. The relationship between pH value of the HPLC eluent and the logP{sub ow} is discussed, illustrated by chromatograms, graphics and tables. The results are also compared with those elaborated by. E. Dudar and presented above. (author)

  5. Optimization and validation of bioanalytical SPE – HPLC method for the simultaneous determination of carbamazepine and its main metabolite, carbamazepine-10, 11-epoxide, in plasma

    Directory of Open Access Journals (Sweden)

    Jasmina Tonic – Ribarska

    2012-03-01

    Full Text Available Carbamazepine is widely used as an antiepileptic drug in the treatment of partial and generalized tonic-clonic seizures. Carbamazepine 10,11-epoxide is the most important metabolite of carbamazepine, because it is a pharmacologically active compound with anticonvulsant properties. According to that, the routine analysis of carbamazepine 10,11-epoxide along with carbamazepine may provide optimal therapeutic monitoring of carbamazepine treatment. The aim of this study was to optimize and validate a simple and reliable solid - phase extraction method followed by RP-HPLC for the simultaneous determination of plasma levels of carbamazepine and carbamazepine-10,11-epoxide, in order to assure the implementation of the method for therapeutic monitoring. The extraction of the analytes from the plasma samples was performed by means of a solid-phase extraction procedure. The separation was carried out on a reversed-phase column using isocratic elution with acetonitrile and water (35:65, v/v as a mobile phase. The temperature was 30°C and UV detection was set at 220 nm. The extraction yield values were more than 98% for all analytes, measured at four concentration levels of the linear concentration range. The method displayed excellent selectivity, sensitivity, linearity, precision and accuracy. Stability studies indicate that stock solutions and plasma samples were stabile under different storage conditions at least during the observed period. The method was successfully applied to determine the carbamazepine and carbamazepine-10,11-epoxide in plasma of epileptic patients treated with carbamazepine as monotherapy and in polytherapy. In conclusion, the proposed method is suitable for application in therapeutic drug monitoring of epileptic patients undergoing treatment with carbamazepine.

  6. Nonlinear Time Reversal Acoustic Method of Friction Stir Weld Assessment, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the project is demonstration of the feasibility of Friction Stir Weld (FSW) assessment by novel Nonlinear Time Reversal Acoustic (TRA) method. Time...

  7. Development of an analytical method for the determination of histamine in fish by liquid chromatography of high performance in reverse phase

    International Nuclear Information System (INIS)

    Valverde Chavarria, Juan Carlos; Barquero Quiros, Mirian

    2004-01-01

    The histamine is a biogenic amine able to promote allergic intoxications in sensitive persons. For this reason is necessary to have a method of analysis with sensitivity, precision and accuracy able to quantify lower amounts than actual FDA Normative sets. A reverse phase chromatographic method was developed. To identify and quantify histamine through automatic generation of histamine derivative of OPA, using an ultraviolet detector, performance parameters of developed method were adequate to quantification of histamine amount lower than FDA Normative. (Author) [es

  8. Quantitative determination of triterpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    Science.gov (United States)

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  9. Quantitative determination of triperpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    Science.gov (United States)

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  10. Application of perfluorinated acids as ion-pairing reagents for reversed-phase chromatography and retention-hydrophobicity relationships studies of selected beta-blockers.

    Science.gov (United States)

    Flieger, J

    2010-01-22

    The addition of the homologous series of perfluorinated acids-trifluoroacetic acid (TFAA), pentafluoropropionic acid (PFPA), heptafluorobutyric acid (HFBA) to mobile phases for reversed-phase high-performance liquid chromatography (RP-HPLC) of beta-blockers was tested. Acidic modifiers were responsible for acidification of mobile phase (pH 3) ensuring the protonation of the beta-blockers and further ion pairs creation. The effect of the type and concentration of mobile phase additives on retention parameters, the efficiency of the peaks, their symmetry and separation selectivity of the beta-blockers mixture were all studied. It appeared that at increasing acid concentration, the retention factor, for all compounds investigated, increased to varying degrees. It should be stressed that the presence of acids more significantly affected the retention of the most hydrophobic beta-blockers. Differences in hydrophobicity of drugs can be maximized through variation of the hydrophobicity of additives. Thus, the relative increase in the retention depends on either concentration and hydrophobicity of the anionic mobile phase additive or hydrophobicity of analytes. According to QSRR (quantitative structure retention relationship) methodology, chromatographic lipophilicity parameters: isocratic log k and log k(w) values (extrapolated retention to pure water) were correlated with the molecular (log P(o/w)) and apparent (log P(app)) octanol-water partition coefficients obtained experimentally by countercurrent chromatography (CCC) or predicted by Pallas software. The obtained, satisfactory retention-hydrophobicity correlations indicate that, in the case of the basic drugs examined in RP-HPLC systems modified with perfluorinated acids, the retention is mainly governed by their hydrophobicity. Copyright 2009 Elsevier B.V. All rights reserved.

  11. [HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].

    Science.gov (United States)

    Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan

    2014-11-01

    To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.

  12. Determination of benzodiazepines in beverages using green extraction methods and capillary HPLC-UV detection.

    Science.gov (United States)

    Piergiovanni, Maurizio; Cappiello, Achille; Famiglini, Giorgio; Termopoli, Veronica; Palma, Pierangela

    2018-05-30

    Dispersive liquid-liquid microextraction with and without ultrasound assistance (DLLME, UA-DLLME) and microextraction with packed sorbent (MEPS) methods for the extraction and determination of eight different benzodiazepines (BDZ) (chlordiazepoxide, flurazepam, bromazepam, oxazepam, lorazepam, clobazam, clonazepam, and flunitrazepam) in three commercial non-alcoholic and light alcoholic beverages were optimized and compared. Benzodiazepines are frequently used for their extensive diffusion and strong numbing effect in drug-facilitated crimes (DFC). The tiny small amount of sample required for DLLME and MEPS extraction makes them very suitable for specimens collected at the crime scene of DFCs. Microextraction techniques are of increasing interest thanks to their accordance to green analytical chemistry (GAC) guidelines providing good recovery values. Ultrasound assistance (UA-DLLME) was used to investigate whether this type of energy can improve the recoveries of the analytes. Analyses of the extracts were performed with reverse-phase capillary high-performance liquid chromatography with UV detection (HPLC - UV), thanks to low environmental impact, robustness, diffusion, and affordability. Recovery percentages at three different concentrations in the three beverages were between 14.30% and 103.28% with intraday and interday RSD lower than ±2.78%. The same samples were extracted using a MEPS protocol, and the results were compared with those obtained with DLLME. MEPS gave recoveries between 20.90% and 101.88% for all matrices showing a better performance than DLLME at higher concentrations, though lower recoveries were observed with diluted samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Radiation degradation of waste waters. Reverse phase-high performance liquid chromatography and multicomponent UV-VIS analysis of gamma-irradiated aqueous solutions of nitrobenzene Pt.1

    International Nuclear Information System (INIS)

    Kuruc, J.; Sahoo, M.K.; Locaj, J.; Hutta, M.

    1994-01-01

    Saturated aqueous solutions of nitrobenzene (in water, 0.1M nitric acid and 0.1M potassium hydroxide) were irradiated with 60 Co γ-rays in deaerated condition. Radiolytic products were analyzed using reverse phase-high performance liquid chromatography (RP-HPLC) and multicomponent UV-VIS spectrometry. With the aid of RP-HPLC retention times of the radiolytic products were found to be identical with those of isomeric nitrophenols, aminophenols and dinitrophenols. According to the primary information obtained from RP-HPLC and literature, we have chosen ten standards and eleven wavelengths for multicomponent UV-VIS analysis (linear multiparametric regression analysis) and the concentrations of nitrobenzene, nitrophenols, aminophenols and dinitrophenols in water, HNO 3 and KOH solutions were calculated. G-values (molecules/100 eV) of the radiolytic products and decomposition of nitrobenzene in aqueous solutions G(-nitrobenzene) were calculated from the dependence of their concentrations with dose. Ph has relatively little influence on the decrease of concentration of nitrobenzene, but has strong influence on the product composition. (author) 7 refs.; 5 figs.; 5 tabs

  14. Synthesis and HPLC evaluation of carboxylic acid phases on a hydride surface.

    Science.gov (United States)

    Pesek, Joseph J; Matyska, Maria T; Gangakhedkar, Surekha; Siddiq, Rukhsana

    2006-04-01

    Three organic moieties containing carboxylic acid functional groups are attached to a particulate silica surface through silanization/hydrosilation. Two compounds (undecylenic acid and 10-undecynoic acid) have 11 carbon chains and the other is a five-carbon acid (pentenoic acid). Bonding is confirmed through carbon elemental analysis, diffuse reflectance infrared fourier transform spectroscopy, and carbon-13 and silicon-29 CP-MAS NMR spectroscopy. The bonded phases are tested by HPLC using PTH amino acids, nucleic acids, theophylline-related compounds, anilines, benzoic acid compounds, choline, and tobramycin. The latter two compounds are used to investigate the aqueous normal phase properties of the three bonded materials.

  15. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    Science.gov (United States)

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Advanced analytical methods for the structure elucidation of polystyrene-b-poly(n-butyl acrylate) block copolymers prepared by reverse iodine transfer polymerisation

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Trevor Gavin; Pfukwa, Helen; Pasch, Harald, E-mail: hpasch@sun.ac.za

    2015-09-10

    Reverse iodine transfer polymerisation (RITP) is a living radical polymerisation technique that has shown to be feasible in synthesising segmented styrene-acrylate copolymers. Polymers synthesised via RITP are typically only described regarding their bulk properties using nuclear magnetic resonance spectroscopy and size exclusion chromatography. To fully understand the complex composition of the polymerisation products and the RITP reaction mechanism, however, it is necessary to use a combination of advanced analytical methods. In the present RITP procedure, polystyrene was synthesised first and then used as a macroinitiator to synthesise polystyrene-block-poly(n-butyl acrylate) (PS-b-PBA) block copolymers. For the first time, these PS-b-PBA block copolymers were analysed by a combination of SEC, in situ{sup 1}H NMR and HPLC. {sup 1}H NMR was used to determine the copolymer composition and the end group functionality of the samples, while SEC and HPLC were used to confirm the formation of block copolymers. Detailed information on the living character of the RITP process was obtained. - Highlights: • Comprehensive analysis of novel block copolymers. • Polymers were prepared for the first time by reverse iodine transfer polymerisation. • Combination of SEC, NMR, kinetic NMR, HPLC and comprehensive 2D-HPLC was used. • Detailed information about complex molecular composition and polymerisation kinetics was obtained.

  17. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    Science.gov (United States)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  18. Applications of the solvation parameter model in reversed-phase liquid chromatography.

    Science.gov (United States)

    Poole, Colin F; Lenca, Nicole

    2017-02-24

    The solvation parameter model is widely used to provide insight into the retention mechanism in reversed-phase liquid chromatography, for column characterization, and in the development of surrogate chromatographic models for biopartitioning processes. The properties of the separation system are described by five system constants representing all possible intermolecular interactions for neutral molecules. The general model can be extended to include ions and enantiomers by adding new descriptors to encode the specific properties of these compounds. System maps provide a comprehensive overview of the separation system as a function of mobile phase composition and/or temperature for method development. The solvation parameter model has been applied to gradient elution separations but here theory and practice suggest a cautious approach since the interpretation of system and compound properties derived from its use are approximate. A growing application of the solvation parameter model in reversed-phase liquid chromatography is the screening of surrogate chromatographic systems for estimating biopartitioning properties. Throughout the discussion of the above topics success as well as known and likely deficiencies of the solvation parameter model are described with an emphasis on the role of the heterogeneous properties of the interphase region on the interpretation and understanding of the general retention mechanism in reversed-phase liquid chromatography for porous chemically bonded sorbents. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Analysis of Dithiocarbamate Fungicides in Vegetable Matrices Using HPLC-UV Followed by Atomic Absorption Spectrometry.

    Science.gov (United States)

    Al-Alam, Josephine; Bom, Laura; Chbani, Asma; Fajloun, Ziad; Millet, Maurice

    2017-04-01

    A simple method combining ion-pair methylation, high-performance liquid chromatography (HPLC) analysis with detection at 272 nm and atomic absorption spectrometry was developed in order to determine 10 dithiocarbamate fungicides (Dazomet, Metam-sodium, Ferbam, Ziram, Zineb, Maneb, Mancozeb, Metiram, Nabam and Propineb) and distinguish ethylenbisdithiocarbamates (EBDTCs) Zineb, Maneb and Mancozeb in diverse matrices. This method associates reverse phase analysis by HPLC analysis with detection at 272 nm, with atomic absorption spectrometry in order to distinguish, with the same extraction protocol, Maneb, Mancozeb and Zineb. The limits of detection (0.4, 0.8, 0.5, 1.25 and 1.97) and quantification (1.18, 2.5, 1.52, 4.2 and 6.52) calculated in injected nanogram, respectively, for Dazomet, Metam-Na, dimethyldithiocarbamates (DMDTCs), EBDTCs and propylenebisdithiocarbamates (PBDTCs) justify the sensitivity of the method used. The coefficients of determination R2 were 0.9985, 0.9978, 0.9949, 0.988 and 0.9794, respectively, for Dazomet, Metam-Na, DMDTCs, EBDTCs and PBDTCs, and the recovery from fortified apple and leek samples was above 90%. Results obtained with the atomic absorption method in comparison with spectrophotometric analysis focus on the importance of the atomic absorption as a complementary specific method for the distinction between different EBDTCs fungicides. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Rapid determination of flavonoids and phenolic acids in grape juices and wines by RP-HPLC/DAD: Method validation and characterization of commercial products of the new Brazilian varieties of grape.

    Science.gov (United States)

    Padilha, Carla Valéria da Silva; Miskinis, Gabriela Aquino; de Souza, Marcelo Eduardo Alves Olinda; Pereira, Giuliano Elias; de Oliveira, Débora; Bordignon-Luiz, Marilde Terezinha; Lima, Marcos Dos Santos

    2017-08-01

    A method for rapid determination of phenolic compounds by reversed-phase high-performance liquid chromatography (RP-HPLC), using a new column of faster resolution was validated and used to characterize commercial products produced with new grape Brazilian varieties of Northeast of Brazil. The in vitro antioxidant activity was also measured. The method showed linearity (R>0.9995), good precision (CV%<2.78), recovery (91.8-105.1%) and limits of detection (0.04-0.85mgL -1 ) and quantification (0.04-1.41mgL -1 ) according to other methods previously published with the difference of a run time of only 25min. The results obtained in the characterization of the samples differed for juices and wines from other world regions, mainly because of the high values of (-)-epigallocatechin and trans-caftaric acid. The products analyzed showed high antioxidant activity, especially the wine samples with values higher than those from wines of different regions of the world. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    Science.gov (United States)

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  3. HPLC determination of chloride, bromide and iodide ions in drinking water and industrial effluents using trifluoromethylmercuric nitrate as derivatizing reagent

    International Nuclear Information System (INIS)

    Arain, M.A.; Bhanger, M.I.; Khuhawar, M.Y.

    1997-01-01

    A simple procedure for the simultaneous determination of various halides in drinking water and industrial effluents of Hyderabad and Iodized salt is reported. The method utilizes derivatization of halides through trifluoromethylmercuric nitrate in aqueous solution, extraction in petroleum ether followed by reverse phase HPLC separation using c-18 Lichrosorb column, 150 x 4 mm i.d., mobile phase methanol : water (20: 80) and UV detection at 225 nm. Linear calibration ranges for chloride, bromide and iodide (0-10 ug/mL) with correlation coefficient 0.996, 0.998 and 0.989 have been determined with lowest possible detection limit as 1.0, 0.25 and 1.5 Mu g/ml, respectively. The effect of various interfering ions is also discussed. (author)

  4. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  5. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Development and Validation of a RP-HPLC Method for the Simultaneous Determination of Rifampicin and a Flavonoid Glycoside - A Novel ... range, accuracy, precision, limit of detection, limit of quantification, robustness and specificity.

  6. Diversity oriented high-throughput screening of 1,3,4-oxadiazole modified chlorophenylureas and halogenobenzamides by HPLC with peptidomimetic calixarene-bonded stationary phases.

    Science.gov (United States)

    Bazylak, Grzegorz; Malak, Anna; Ali, Imran; Borowiak, Teresa; Dutkiewicz, Grzegorz

    2008-06-01

    Retention profiles in series of the neutral and highly hydrophobic 1,3,4-oxadiazoles containing chlorophenylurea and halogenobenzamide moiety and indicating analgesic activity were determined in the isocratic standard- and narrow-bore HPLC systems employing, respectively, various octadecylsilica and different calixarene bonded stationary phases. When acetonitrile - 2.65 mM phosphoric acid (55 : 45, %, v/v), pH* 3.25, mobile phase was applied retention of these compounds increased with decline of their overall hydrophobicity according to the general preference of more polar compounds by calixarene cavity in time of its non-specific host-guest supramolecular interactions with halogenated substances. The size of calixarene nanocavity and its upper-rim substitution did not change the observed retention order, resolution and selectivity of separation for oxadiazoles. Compared to the retention on the non-end-capped and the highly-end-capped octadecylsilica HPLC column a most improved separation of some regioisomers of halogenated 1,3,4-oxadiazoles were observed on both used calixarene-type HPLC supports. In addition, preliminary data on the self-assembled supramolecular crystal structure of exemplary 1,3,4-oxadiazolchlorophenylurea with cis-elongated conformation was reported and formation of the monovalent inclusion host-guest complexes between 1,3,4-oxadiazoles and each calixarene-type stationary phase was studied with molecular modelling MM+ and AM1 methods. The structural, isomeric and energetic factors leading to the hydrogen bond stabilized inclusion complexes between these species were considered and used for explanation of observed retention sequence and selectivity of 1,3,4-oxadiazoles separation in applied calixarene-based HPLC systems. All these data would be useful in future development of optimized procedures enabling encapsulation of 1,3,4-oxadiazolurea-type drugs with calixarenes.

  7. A Validated RP-HPLC Method for the Determination of Atazanavir in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    K. Srinivasu

    2011-01-01

    Full Text Available A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5 with acetonitrile (55:45 v/v. Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.

  8. RP-HPLC Determination of Atomoxetine Hydrochloride in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    H. R. Prajapati

    2011-01-01

    Full Text Available A reversed phase high performance liquid chromatographic (RP–HPLC method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm using methanol: 50 mM KH2PO2 buffer (PH adjusted to 6.8 with 0.1 M NaOH, 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.

  9. RP-HPLC assay method development for Paracetamol and Lornoxicam in combination and characterization of oxidative degradation products of Lornoxicam

    OpenAIRE

    Jain Pritam S.; Patel Miketa A.; Chaudhari Amar J.; Surana Sanjay J.

    2013-01-01

    A simple, specific, accurate and precise reverse phase high pressure liquid chromatographic method has been developed for the simultaneous determination of Paracetamol and Lornoxicam from tablets and to characterize degradation products of Lornoxicam by reverse phase C18 column (Inertsil ODS 3V C-18, 250 x 4.6 mm, 5 μ). The sample was analyzed using Buffer (0.02504 Molar): Methanol in the ratio of 45:55, as a mobile phase at a flow rate of 1.5 mL/min and de...

  10. Application of spectrophotometric, densitometric, and HPLC techniques as stability indicating methods for determination of Zaleplon in pharmaceutical preparations

    Science.gov (United States)

    Metwally, Fadia H.; Abdelkawy, M.; Abdelwahab, Nada S.

    2007-12-01

    Spectrophotometric, spectrodensitometric and HPLC are stability indicating methods described for determination of Zaleplon in pure and dosage forms. As Zaleplon is easily degradable, the proposed techniques in this manuscript are adopted for its determination in presence of its alkaline degradation product, namely N-[4-(3-cyano-pyrazolo[1,5a]pyridin-7-yl)-phenyl]- N-ethyl-acetamide. These approaches are successfully applied to quantify Zaleplon using the information included in the absorption spectra of appropriate solutions. The second derivative (D 2) spectrophotometric method, allows determination of Zaleplon without interference of its degradate at 235.2 nm using 0.01N HCl as a solvent with obedience to Beer's law over a concentration range of 1-10 μg ml -1 with mean percentage recovery 100.24 ± 0.86%. The first derivative of the ratio spectra ( 1DD) based on the simultaneous use of ( 1DD) and measurement at 241.8 nm using the same solvent and over the same concentration range as (D 2) spectrophotometric method, with mean percentage recovery 99.9 ± 1.07%. The spectrodensitometric analysis allows the separation and quantitation of Zaleplon from its degradate on silica gel plates using chloroform:acetone:ammonia solution (9:1:0.2 by volume) as a mobile phase. This method depends on quantitave densitometric evaluation of thin layer chromatogram of Zaleplon at 338 nm over a concentration range of 0.2-1 μg band -1, with mean percentage recovery 99.73 ± 1.35. Also a reversed-phase liquid chromatographic method using 5-C8 (22 cm × 4.6 mm i.d. 5 μm particle size) column was described and validated for quantitation of Zaleplon using acetonitrile:deionised water (35:65, v/v) as a mobile phase using Paracetamol as internal standard and a flow rate of 1.5 ml min -1 with UV detection of the effluent at 232 nm at ambient temperature over a concentration range of 2-20 μg ml -1 with mean percentage recovery 100.19 ± 1.15%. The insignificance difference of the proposed

  11. Development and Validation of a HPLC Method for the Determination of Lacidipine in Pure Form and in Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Vinodh, M.; Vinayak, M.; Rahul, K.; Pankaj, P.

    2012-01-01

    A simple and reliable high-performance liquid chromatography (HPLC) method was developed and validated for Lacidipine in pure form and pharmaceutical dosage form. The method was developed on X bridge C-18 column (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of ammonium acetate and acetonitrile. The effluent was monitored by PDA detector at 240 nm. Calibration curve was linear over the concentration range of 50-250 μg/ml. For Intra-day and inter-day precision % RSD values were found to be 0.83 % and 0.41 % respectively. Recovery of Lacidipine was found to be in the range of 99.78-101.76 %. The limits of detection (LOD) and quantification (LOQ) were 1.0 and 7.3 μg/ml respectively. The developed RP-HPLC method was successfully applied for the quantitative determination of lacidipine in pharmaceutical dosage. (author)

  12. Stainless austenitic steels strengthened due to reversible phase transformations and by ageing

    International Nuclear Information System (INIS)

    Sagaradze, V.V.; Kositsyna, I.I.; Ozhiganov, A.V.

    1981-01-01

    The effect of the reversible phase transformations, consisting in the conduction of the direct and reverse martensite transformations and aging, during which the intermetallide γ'-phase of the composition Ni 3 Ti is formed, on the streng-thening of alloys in the Fe-Cr-Ni-Ti system is considered. Stainless austenitic steels Kh12N12T3 and Kh12N14T3, which acquire high mechanical properties: σsub(0.2)=685-785 MPa, σsub(B)=1275 MPa, delta >= 20%, as a result of reversible phase transformations and aging, are suggested. After the reversible phase transformations and ageing the steels possess a high resistance to γ-α-transformation during cold treatment [ru

  13. Stability-Indicating HPLC Method for Simultaneous Determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in Ophthalmic Solution.

    Science.gov (United States)

    AlAani, Hashem; Alnukkary, Yasmin

    2016-03-01

    A simple stability-indicating RP-HPLC assay method was developed and validated for quantitative determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in ophthalmic solution in the presence of 2-amino-1-(4-nitrophenyl)propane-1,3-diol, a degradation product of Chloramphenicol, and Dexamethasone, a degradation product of Dexamethasone Sodium Phosphate. Effective chromatographic separation was achieved using C18 column (250 mm, 4.6 mm i.d., 5 μm) with isocratic mobile phase consisting of acetonitrile - phosphate buffer (pH 4.0; 0.05 M) (30:70, v/v) at a flow rate of 1 mL/minute. The column temperature was maintained at 40°C and the detection wavelength was 230 nm. The proposed HPLC procedure was statistically validated according to the ICH guideline, and was proved to be stability-indicating by resolution of the APIs from their forced degradation products. The developed method is suitable for the routine analysis as well as stability studies.

  14. Tandem solid-phase extraction followed by HPLC-ESI/QTOF/MS/MS for rapid screening and structural identification of trace diterpenoids in flowers of Rhododendron molle.

    Science.gov (United States)

    Zou, Hong-Yan; Luo, Jun; Xu, De-Ran; Kong, Ling-Yi

    2014-01-01

    'Naoyanghua', composed of the flowers of Rhododendron molle G. Don, is a traditional Chinese medicine that is widely known for its toxicity. Grayanane-type diterpenoids are the main active ingredients in R. molle, as well as possibly their toxicity: they are, however, difficult to isolate and analyse using common chromatographic methods, due to their small amounts and absence of conjugated groups, such as phenyl and α, β-unsaturated ketone. To establish a highly sensitive, selective and reliable method for the qualitative evaluation of trace diterpenoids in the flowers of R. molle by using tandem solid-phase extraction followed by high-performance liquid chromatography with electrospray ionisation quadrupole-time-of-flight mass spectrometry (HPLC-ESI/QTOF/MS/MS). Tandem solid phase extraction (SPE) was undertaken using a polyamide cartridge and a C18E cartridge in succession to enrich the trace diterpenoids. HPLC-ESI/QTOF/MS/MS was used to determine the fragmentation patterns of diterpenoids and to tentatively characterise their fragmentation pathways. HPLC-ESI/QTOF/MS/MS detected a total of 14 diterpenoids, eight of which were identified by comparison with literature sources and six based on fragmentation analysis. Among the latter six, rhodojaponin VI-3-glucoside was tentatively identified as a new diterpenoid glycoside and rhodojaponin VII, rhodojaponin IV and rhodojaponin I were reported from R. molle for the first time. By qualitative research of diterpenoids in this plant by HPLC-ESI/QTOF/MS/MS, a reliable methodology for the analysis of these active constituents of R. molle was established for the first time. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    S. K. Patro

    2010-01-01

    Full Text Available A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/mL using 0.01 M NH4H2PO4 (pH 3.5 buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 mL/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.

  16. Differential screening and mass mapping of proteins from premalignant and cancer cell lines using nonporous reversed-phase HPLC coupled with mass spectrometric analysis.

    Science.gov (United States)

    Chong, B E; Hamler, R L; Lubman, D M; Ethier, S P; Rosenspire, A J; Miller, F R

    2001-03-15

    Nonporous (NPS) RP-HPLC has been used to rapidly separate proteins from whole cell lysates of human breast cell lines. The nonporous separation involves the use of hard-sphere silica beads of 1.5-microm diameter coated with C18, which can be used to separate proteins ranging from 5 to 90 kDa. Using only 30-40 microg of total protein, the protein molecular weights are detectable on-line using an ESI-oaTOF MS. Of hundreds of proteins detected in this mass range, approxinately 75-80 are more highly expressed. The molecular weight profiles can be displayed as a mass map analogous to a virtual "1-D gel" and differentially expressed proteins can be compared by image analysis. The separated proteins can also be detected by UV absorption and differentially expressed proteins quantified. The eluting proteins can be collected in the liquid phase and the molecular weight and peptide maps determined by MALDI-TOF MS for identification. It is demonstrated that the expressed protein profiles change during neoplastic progression and that many oncoproteins are readily detected. It is also shown that the response of premalignant cancer cells to estradiol can be rapidly screened by this method, demonstrating significant changes in response to an external agent. Ultimately, the proteins can be studied by peptide mapping to search for posttranslational modifications of the oncoproteins accompanying progression.

  17. Temperature induced reversible polymorphic phase transformations in a bis-hydrazone compound

    Science.gov (United States)

    Jayant, Vikrant; Das, Dinabandhu

    2018-03-01

    Two reversible polymorphic phase transformation of 2,3-butanedione, 2,3- bis[4,4‧-bis(diethylamino)benzophenone hydrazone] (DEBH) have been identified in DSC experiment. Topotactic phase transformation of three polymorphs has been observed in variable temperature Single Crystal X-ray Diffraction experiment. The reversible phase transformation of bulk material has been confirmed by Powder X-ray diffraction study.

  18. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found...... essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method...

  19. Determination of Picloram in Soil and Water by Reversed-Phase Liquid Chromatography

    Science.gov (United States)

    M.J.M. Wells; J.L. Michael; D.G. Neary

    1984-01-01

    A reversed-phase liquid chromatographic method is presneted for the determination of picloram in the parts per billion (ppb) range in soil, soil solution, and stream samples. Quanitification is effected by UV absorpation at 254 nm. Derivatization is not necessary. The method permits 92% ± 7.1 recovery from water samples and 61.8% ± 11.1 recovery from soil samples....

  20. Rapid and Reliable HPLC Method for the Determination of Vitamin ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantitation of vitamin C in pharmaceutical samples. Method: The drug and the standard were eluted from Superspher RP-18 (250 mm x 4.6 mm, 10ìm particle size) at 20 0C.

  1. Development and Validation of RP-HPLC Method for Simultaneous Estimation of Aspirin and Esomeprazole Magnesium in Tablet Dosage Form

    Directory of Open Access Journals (Sweden)

    Dipali Patel

    2013-01-01

    Full Text Available A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of aspirin and esomeprazole magnesium in tablet dosage forms. The separation was achieved by HyperChrom ODS-BP C18 column (200 mm × 4.6 mm; 5.0 μm using acetonitrile: methanol: 0.05 M phosphate buffer at pH 3 adjusted with orthophosphoric acid (25 : 25 : 50, v/v as eluent, at a flow rate of 1 mL/min. Detection was carried out at wavelength 230 nm. The retention times of aspirin and esomeprazole magnesium were 4.29 min and 6.09 min, respectively. The linearity was established over the concentration ranges of 10–70 μg/mL and 10–30 μg/mL with correlation coefficients (r2 0.9986 and 0.9973 for aspirin and esomeprazole magnesium, respectively. The mean recoveries were found to be in the ranges of 99.80–100.57% and 99.70–100.83% for aspirin and esomeprazole magnesium, respectively. The proposed method has been validated as per ICH guidelines and successfully applied to the estimation of aspirin and esomeprazole magnesium in their combined tablet dosage form.

  2. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    Science.gov (United States)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  3. Martensite shear phase reversion-induced nanograined/ultrafine-grained Fe-16Cr-10Ni alloy: The effect of interstitial alloying elements and degree of austenite stability on phase reversion

    Energy Technology Data Exchange (ETDEWEB)

    Misra, R.D.K., E-mail: dmisra@louisiana.edu [Center for Structural and Functional Materials, University of Louisiana at Lafayette, Madison Hall Room 217, P.O. Box 44130, Lafayette, LA 70504-1430 (United States); Zhang, Z.; Venkatasurya, P.K.C. [Center for Structural and Functional Materials, University of Louisiana at Lafayette, Madison Hall Room 217, P.O. Box 44130, Lafayette, LA 70504-1430 (United States); Somani, M.C.; Karjalainen, L.P. [Department of Mechanical Engineering, University of Oulu, P.O. Box 4200, Oulu 90014 (Finland)

    2010-11-15

    Research highlights: {yields} Development of a novel process involving phase-reversion annealing process. {yields} Austensite stability strongly influences development of nanograined structure. {yields} Interstitial elements influence microstructural evolution during annealing. - Abstract: We describe here an electron microscopy study of microstructural evolution associated with martensitic shear phase reversion-induced nanograined/ultrafine-grained (NG/UFG) structure in an experimental Fe-16Cr-10Ni alloy with very low interstitial content. The primary objective is to understand and obtain fundamental insights on the influence of degree of austenite stability (Fe-16Cr-10Ni, 301LN, and 301 have different austenite stability index) and interstitial elements (carbon and nitrogen) in terms of phase reversion process, microstructural evolution during reversion annealing, and temperature-time annealing sequence. A relative comparison of Fe-16Cr-10Ni alloy with 301LN and 301 austenitic stainless steels indicated that phase reversion in Fe-16Cr-10Ni occurred by shear mechanism, which is similar to that observed for 301, but is different from the diffusional mechanism in 301LN steel. While the phase reversion in the experimental Fe-16Cr-10Ni alloy and 301 austenitic stainless steel occurred by shear mechanism, there were fundamental differences between these two alloys. The reversed strain-free austenite grains in Fe-16Cr-10Ni alloy were characterized by nearly same crystallographic orientation, where as in 301 steel there was evidence of break-up of martensite laths during reversion annealing resulting in several regions of misoriented austenite grains in 301 steel. Furthermore, a higher phase reversion annealing temperature range (800-900 deg. C) was required to obtain a fully NG/UFG structure of grain size 200-600 nm. The difference in the phase reversion and the temperature-time sequence in the three stages is explained in terms of Gibbs free energy change that

  4. [Study on HPLC-FPS of raw and processed fructus polygoni orientalis].

    Science.gov (United States)

    Zhai, Yanjun; Zhao, Min; Zhang, Hui; Chu, Zhengyun; Kang, Tingguo

    2010-03-01

    To establish the HPLC fingerprint method of Fructus Polygoni Orientalis before and after processed by choosing taxifolin as reference to compare the changes of chemical composition. HPLC method was emplyed with a gradient elution phase in a flow rate of 1 mL x min(-1) and the detection wavelength of 270 nm. Twenty marker peaks were marked out in the raw samples and 33 marker peaks in the processed product. Methodology met was consistent with the requirement, similarity was exceeded 0.9. This method is stationary, precise and feasible, which provide references of quality control for Fructus Polygoni Orientalis.

  5. Carrier mediated hollow fiber liquid phase microextraction combined with HPLC-UV for preconcentration and determination of some tetracycline antibiotics.

    Science.gov (United States)

    Shariati, Shahab; Yamini, Yadollah; Esrafili, Ali

    2009-02-01

    In the present study, a simple and efficient preconcentration method was developed using carrier mediated three phase liquid phase microextraction prior to HPLC-UV for simultaneous extraction and determination of trace amounts of highly hydrophilic tetracycline antibiotics including tetracycline (TCN), oxytetracycline (OTCN) and doxycycline (DCN) in bovine milk, human plasma and water samples. For extraction, 11.0 mL of the aqueous sample containing TCNs and 0.05 M Na(2)HPO(4) (9.10.995). Finally, applicability of the proposed method was successfully confirmed by extraction and determination of the drugs in water and plasma samples as well as in bovine milk samples with low and high fat contents. Comparing to the traditional methods, the proposed method exhibits high sensitivity and high preconcentration factors as well as good precision. The extraction setup is simple and due to active transport of analytes, high cleanup effect and good selectivity are obtained in extraction process.

  6. Simultaneous determination of ascorbic acid and caffeine in commercial soft drinks using reversed-phase ultraperformance liquid chromatography.

    Science.gov (United States)

    Turak, Fatma; Güzel, Remziye; Dinç, Erdal

    2017-04-01

    A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C 18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H 3 PO 4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances. Copyright © 2016. Published by Elsevier B.V.

  7. Simultaneous determination of ascorbic acid and caffeine in commercial soft drinks using reversed-phase ultraperformance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Fatma Turak

    2017-04-01

    Full Text Available A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA and caffeine (CAF in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C18 column (100 mm × 2.1 mm, 1.7 μm i.d., using a mobile phase consisting of acetonitrile and 0.2M H3PO4 (11:89, v/v with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances.

  8. Authenticity analysis of citrus essential oils by HPLC-UV-MS on oxygenated heterocyclic components

    Directory of Open Access Journals (Sweden)

    Hao Fan

    2015-03-01

    Full Text Available Citrus essential oils are widely applied in food industry as the backbone of citrus flavors. Unfortunately, due to relatively simple chemical composition and tremendous price differences among citrus species, adulteration has been plaguing the industry since its inception. Skilled blenders are capable of making blends that are almost indistinguishable from authentic oils through conventional gas chromatography analysis. A reversed-phase high performance liquid chromatography (HPLC method was developed for compositional study of nonvolatile constituents in essential oils from major citrus species. The nonvolatile oxygenated heterocyclic components identified in citrus oils were proved to be more effective as markers in adulteration detection than the volatile components. Authors are hoping such an analysis procedure can be served as a routine quality control test for authenticity evaluation in citrus essential oils.

  9. Study of the separation of fluoroquinolones using HPLC: Application to the study of their degradation by gamma radiation

    International Nuclear Information System (INIS)

    Ben Saad, Latifa

    2013-01-01

    A method of high performance liquid chromatography (HPLC) in reverse phase was developed for the separation of a mixture of five fluoroquinolones (lomefloxacin, ciprofloxacin, levofloxacin, enoxacin and enrofloxacin). The optimum operating conditions are: the wavelength of detection is fixed at 282nm DAD detector, the stationary phase consists of silica type X scratched Terra RP-18 (250mm x 4, 6 mm, 5μm) and the mobile phase consisted of acetonitrile and phosphate buffer (0.02 M) (20: 80 v: v), pH equal to flow rate of 1ml/M/Xin 3etde. This optimized method was applied to analyze the solutions of different concentrations of each fluoroquinolone (100 and 20 ppm) after irradiation with doses of gamma radiation (5 and 25 kGry). The study of the effect of such radiation on fluoroquinolones shows that with a dose of 5 kGry these radiations allow complete degradation of these active ingredients at a concentration of 20 ppm and the appearance of other degradation products. But a dose of 5 kGry is insufficient to degrade the active ingredients (100ppm).

  10. Arsenic speciation in biological environmental samples of aquatic ecosystems by using HPLC-ICP-MS; Speciation von Arsen in biologischen Umweltproben aus aquatischen Oekosystemen mittels HPLC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Falk, K.

    1999-09-01

    The physicochemical forms of arsenic (arsenic species) which are present in the environment vary significantly with respect to toxicity, bioavailability, stability and transport behaviour. Therefore, it is necessary for an assessment of the toxic potential to humans and the environment to investigate not only the total arsenic concentrations but also to differentiate the single species. By that the knowledge about ecological correlations and pathways will be increased. The present thesis reports the results of a Ph.D. study on the development and optimisation of analytical methods for arsenic speciation and their application to biological samples from different aquatic ecosystems in Germany. The method development included separation of 12 naturally occurring arsenic species by high-performance liquid chromatography (HPLC) followed by an arsenic selective detection by inductively coupled plasma-mass spectrometry (ICP-MS). The arsenic species As (III), As (V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AB), arsenocholine (AC), trimethylarsine oxid (TMAO) and tetramethylarsonium (Tetra) were separated with ion-exchange chromatography, whereas reversed-phase chromatography was used for the separation of four arsenosugars. Because of the partly low arsenic concentration in biological samples a very good detection power was required. Therefore, an HPLC-ICP-MS system was tested with different nebulizers. Using the high efficiency nebulizer HHPN (Hydraulic High Pressure Nebulizer), detection limits in the low pg-range could be achieved. The developed analytical methods were applied to arsenic speciation in four marine matrices, which are representative of different trophic levels in the food chain. All samples originated from an ecosystem in the North Sea.

  11. Determination of gouty arthritis' biomarkers in human urine using reversed-phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Lei-Wen Xiang

    2014-04-01

    Full Text Available Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography (RP-HPLC with ultraviolet (UV detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26 (5:95. Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957–0.9993. The proposed analytical method has satisfactory repeatability (the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49–97.90%, 95.38–96.45%, 112.46–115.78% and 90.82–97.13% with standard deviation of <5%, respectively and the limits of detection (LODs, S/N≥3 for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L, respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis. Keywords: Gouty arthritis, Creatinine, Uric acid, Hypoxanthine, Xanthine, High-performance liquid chromatography

  12. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Ofosua Adi-Dako

    2017-01-01

    Full Text Available An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18, 5 μm, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98–101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD were 0.19–0.55% and 0.33–0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference (p>0.05 at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations.

  13. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms.

    Science.gov (United States)

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2013-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. The buffer consisted of 0.01 M potassium dihydrogen phosphate with the pH adjusted to 8.0 by using diethylamine. In the developed HPLC method, the resolution between Tolperisone and its four potential impurities was found to be greater than 2.0. Regression analysis showed an R value (correlation coefficient) of greater than 0.999 for the Tolperisone impurities. This method was capable of detecting all four impurities of Tolperisone at a level of 0.19 μg/mL with respect to the test concentration of 1000 μg/mL for a 10 µl injection volume. The tablets were subjected to the stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in base hydrolysis, water hydrolysis, and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 100%. The established method was validated and found to be linear, accurate, precise, specific, robust, and rugged.

  14. HPLC method for rapidly following biodiesel fuel transesterification reaction progress using a core-shell column.

    Science.gov (United States)

    Allen, Samuel J; Ott, Lisa S

    2012-07-01

    There are a wide and growing variety of feedstocks for biodiesel fuel. Most commonly, these feedstocks contain triglycerides which are transesterified into the fatty acid alkyl esters (FAAEs) which comprise biodiesel fuel. While the tranesterification reaction itself is simple, monitoring the reaction progress and reaction products is not. Gas chromatography-mass spectrometry is useful for assessing the FAAE products, but does not directly address either the tri-, di-, or monoglycerides present from incomplete transesterification or the free fatty acids which may also be present. Analysis of the biodiesel reaction mixture is complicated by the solubility and physical property differences among the components of the tranesterification reaction mixture. In this contribution, we present a simple, rapid HPLC method which allows for monitoring all of the main components in a biodiesel fuel transesterification reaction, with specific emphasis on the ability to monitor the reaction as a function of time. The utilization of a relatively new, core-shell stationary phase for the HPLC column allows for efficient separation of peaks with short elution times, saving both time and solvent.

  15. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    All rights reserved. ... 1Department of Pharmacology, 2Department of Applied Science, 3Police Forensic Science Center 10, Yala 95000, 4Natural ... Purpose: To develop a solid phase extraction (SPE) method that utilizes reverse-phase high.

  16. Optimization of a reversed-phase-high-performance thin-layer chromatography method for the separation of isoniazid, ethambutol, rifampicin and pyrazinamide in fixed-dose combination antituberculosis tablets.

    Science.gov (United States)

    Shewiyo, D H; Kaale, E; Risha, P G; Dejaegher, B; Smeyers-Verbeke, J; Vander Heyden, Y

    2012-10-19

    This paper presents the development of a new RP-HPTLC method for the separation of pyrazinamide, isoniazid, rifampicin and ethambutol in a four fixed-dose combination (4 FDC) tablet formulation. It is a single method with two steps in which after plate development pyrazinamide, isoniazid and rifampicin are detected at an UV wavelength of 280 nm. Then ethambutol is derivatized and detected at a VIS wavelength of 450 nm. Methanol, ethanol and propan-1-ol were evaluated modifiers to form alcohol-water mobile phases. Systematic optimization of the composition of each alcohol in the mobile phase was carried out using the window diagramming concept to obtain the best separation. Examination of the Rf distribution of the separated compounds showed that separation of the compounds with the mobile phase containing ethanol at the optimal fraction was almost situated within the optimal Rf-values region of 0.20-0.80. Therefore, ethanol was selected as organic modifier and the optimal mobile phase composition was found to be ethanol, water, glacial acetic acid (>99% acetic acid) and 37% ammonia solution (70/30/5/1, v/v/v/v). The method is new, quick and cheap compared to the actual method in the International Pharmacopoeia for the assay of the 4 FDC tablets, which involves the use of two separate HPLC methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Quantitative analysis of PMR-15 polyimide resin by HPLC

    Science.gov (United States)

    Roberts, Gary D.; Lauver, Richard W.

    1987-01-01

    The concentration of individual components and of total solids of 50 wt pct PMR-15 resin solutions was determined using reverse-phase HPLC to within + or - 8 percent accuracy. Acid impurities, the major source of impurities in 3,3', 4,4'-benzophenonetetracarboxylic acid (BTDE), were eliminated by recrystallizing the BTDE prior to esterification. Triester formation was not a problem because of the high rate of esterification of the anhydride relative to that of the carboxylic acid. Aging of PMR-15 resin solutions resulted in gradual formation of the mononadimide and bisnadimide of 4,4'-methylenedianiline, with the BTDE concentration remaining constant. Similar chemical reactions occurred at a reduced rate in dried films of PMR-15 resin.

  18. Reclaimable Thermally Reversible Polymers for AM Feedstock, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — CRG proposes to continue efforts from the 2016 NASA SBIR Phase I topic H5.04 Reclaimable Thermally Reversible Polymers for AM Feedstock. In Phase II, CRG will refine...

  19. An HPLC method to determine sennoside A and sennoside B in Sennae fructus and Sennae folium.

    Science.gov (United States)

    Rosenthal, Immanuel; Wolfram, Evelyn; Meier, Beat

    2014-01-01

    The current Ph. Eur. monographs for senna pods, senna leaf and senna leaf dry extract standardised describe a photometric assay based on the Bornträger reaction to determine hydroxyanthracene glycosides, calculated as sennoside B. The method is timeconsuming, unspecific for sennosides and the precision is not adequate for a modern assay. The photometric method shall therefore be replaced by a modern HPLC method. About 70 % of the total anthrachinone content in herbal drugs of senna species is due to sennoside A and sennoside B. These substances are therefore suitable for the standardisation of Senna products. The Japanese Pharmacopoeia (JP) already describes an HPLC method to determine sennoside A and sennoside B in the monograph for senna leaf. It uses ion-pair chromatography with tetraheptylammoniumbromide. The procedure described in the monograph has a runtime of 70 min. The adapted and validated method described here uses solid-phase extraction (SPE) which allows a selective sample preparation by using an anion exchange phase. A conventional RP C18 column Tosh TSKgel ODS-80TS (4.6 mm × 150 mm), 5 μm, was used as stationary phase and acetonitrile for chromatography R, water R, phosphoric acid R (200:800:1 V/V/V) as mobile phase. The flow rate was 1.2 mL/min, the column temperature 40 °C, the detection wavelength 380 nm, and the injection volume 20 μL. The runtime is 10 min, the chromatogram shows 2 peaks due to sennoside A/B and 2 additional smaller compounds. One of them is rhein-8-O-glucoside. The procedure has been successfully validated according to ICH guidelines. We analysed 6 batches of Senna. The pods (Senna angustifolia) showed a total content of sennoside A and B of 1.74-2.76 % m/m and the content of senna leaves was clearly lower with 1.07-1.19 % m/m, respectively. The suggested method is considered to be suitable to determine sennoside A and sennoside B in senna leaves and senna pods. The consideration is based on the performed validation and on

  20. Development and validation of a stability-indicating RP-HPLC method for determination of atomoxetine hydrochloride in tablets.

    Science.gov (United States)

    Patel, Sejal K; Patel, Natvarlal J

    2010-01-01

    This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.

  1. Determination of GABA and vigabatrin in human plasma by a rapid and simple HPLC method: correlation between clinical response to vigabatrin and increase in plasma GABA.

    Science.gov (United States)

    Löscher, W; Fassbender, C P; Gram, L; Gramer, M; Hörstermann, D; Zahner, B; Stefan, H

    1993-03-01

    The novel antiepileptic drug vigabatrin (Sabril) acts by inhibiting degradation of the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), increasing the GABA concentrations in the brain. Because the GABA degrading enzyme GABA aminotransferase (GABA-T) is also present in peripheral tissues, including blood platelets, measurement of plasma GABA levels might be a useful indication of the pharmacological response to vigabatrin during therapeutic monitoring. However, because of the very low concentrations of GABA in plasma, the few methods available for plasma GABA analysis are time-consuming, difficult to perform and/or not selective enough because of potential interference with other plasma constituents. In the present study, a rapid, selective and sensitive amino acid analysis HPLC method has been developed for plasma GABA determination with fluorescence detection, using o-phthaldialdehyde as a precolumn derivatizing agent. By employing a 3 microns particle size reversed-phase column and a multi-step gradient system of two solvents, the very low endogenous concentration of GABA in human plasma could be reproducibly quantitated without interference of other endogenous compounds. Incubation of human plasma samples with GABA degrading enzyme(s) resulted in an almost total loss of the GABA peak, thus demonstrating the specificity of the method for GABA analysis. In addition to GABA and other endogenous amino acids, the HPLC method could be used to quantitate plasma levels of vigabatrin. Thus, this improved HPLC amino acid assay might be used to examine whether concomitant monitoring of plasma GABA and vigabatrin is useful for clinical purposes. This was examined in 20 epileptic patients undergoing chronic treatment with vigabatrin. The average plasma GABA level of these 20 patients did not differ significantly from non-epileptic controls. However, when epileptic patients were subdivided according to their clinical response to vigabatrin, vigabatrin responders

  2. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A reversed-phase high-performance liquid chromatography method for the determination of cotrimoxazole (trimethoprim/ sulphamethoxazole) in children treated for malaria

    DEFF Research Database (Denmark)

    Rønn, A M; Mutabingwa, T K; Kreisby, S

    1999-01-01

    A high-performance liquid chromatography (HPLC) method was developed for the simultaneous analysis of trimethoprim (TMP), sulphamethoxazole (SMX), and acetylsulphamethoxazole (AcSMX) in small amounts of blood. The method involved precipitation with 50 microL trichloracetic acid (1M) to 125 micro...

  4. Determination of boron in nuclear materials at subppm levels by high pressure liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Rao, Radhika M.; Aggarwal, S.K.

    2002-11-01

    Experiments were conducted for the determination of boron in U 3 O 8 powder, aluminium metal and milliQ water using dynamically modified Reversed Phase High Pressure Liquid Chromatography (RP-HPLC) and using two precolumn chromogenic agents viz. chromotropic acid and curcumin for complexing boron. The complex was separated from the excess of reagent and determined by HPLC. When present in subppm levels, chromotropic acid was used successfully only for determination boron in water samples. For determination of boron at subppm levels in uranium and aluminium samples, curcumin was used as the precolumn chromogenic agent. The boron curcumin complex (rosocyanin) was formed after extraction of boron with 2-ethyl-l, 3-hexane diol (EHD). The rosocyanin complex was then separated from excess curcumin by displacement chromatography. Linear calibration curves for boron amounts in the range of 0.02 μg to 0.5 μg were developed with correlation coefficients varying from 0.997 to 0.999 and were used for the determination of boron in aluminium and uranium samples. Precision of about 10% was achieved in samples containing less than 1 ppmw of boron. Detection limit of this method is 0.01 μg boron. (author)

  5. Stability-Indicating Validated HPLC Method for Analysis of Berberine Hydrochloride and Trimethoprim in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    Jing-Chun Wang

    2013-01-01

    Full Text Available A stability-indicating HPLC method was developed and validated for the determination of berberine hydrochloride and trimethoprim in pharmaceutical dosage form in the presence of degradation products. The proposed RP-HPLC method utilizes an Agilent TC-C18, 4.6 mm × 250 mm, 5 μm, column using a mobile phase consisting of acetonitrile-50 mM potassium dihydrogen phosphate (30 : 70, v/v, pH adjusted to 3 with orthophosphoric acid at a flow rate of 1.0 mL/min and UV detection at 271 nm. The linearity of berberine hydrochloride and trimethoprim was in the range of 2 to 60 μg/mL (r=0.9996 and 1 to 30 μg/mL (r=0.9995, respectively. Repeatability and intermediate precisions were also determined with percentage relative standard deviation (% RSD less than 2.0%. The limits of detection were found to be 9.8 ng/mL for berberine hydrochloride and 2.5 ng/mL for trimethoprim. The mean recoveries for berberine hydrochloride and trimethoprim were 99.8 and 98.8%, respectively. The stability of the two drugs was determined under different conditions and the proposed method has shown effective separation for their degradation products. And the proposed assays method can thus be considered stability-indicating.

  6. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry); Verma, K.K. (Rani Durgavati Univ., Jabalpur (India). Dept. of Chemistry)

    1993-11-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 [mu]g mL[sup -1] chlorine; the limit of detection found to be 0.01 [mu]g mL[sup -1]. The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  7. HPLC determination of chlorine in air and water samples following precolumn derivatization to 4-bromoacetanilide

    International Nuclear Information System (INIS)

    Jain, A.; Verma, K.K.

    1993-01-01

    Chlorine has been determined in air and water samples by a rapid and sensitive method entailing precolumn derivatization to 4-bromoacetanilide. A mixed potassium bromide - acetanilide reagent was used as a trapping agent for chlorine in air, and for its derivatization. The 4-bromoacetanilide formed was determined by reversed-phase HPLC on an ODS column, using methanol-water, 65:35 (v/v) as mobile phase; detection was at 240 nm. A rectilinear calibration graph was obtained for the range 0.1-30 μg mL -1 chlorine; the limit of detection found to be 0.01 μg mL -1 . The precolumn derivative has been found to have a shelf-life of at least 21 days; this enables the use of the method for samples transported from the field to the analytical laboratory, or the testing of a variety of conditions for chlorine scrubbing studies without the need for immediate analysis of samples. Humic substances do not cause any interference with the proposed method and the presence of nitrite does not lead to artificially high results and consequent misleading conclusions of the presence of high levels of chlorine. (orig.)

  8. A reversed-phase high performance liquid chromatography coupled with resonance Rayleigh scattering detection for the determination of four tetracycline antibiotics

    International Nuclear Information System (INIS)

    Wang Lifeng; Peng Jingdong; Liu Limin

    2008-01-01

    A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm x 4.6 mm; 4 μm) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min -1 . Column temperature was 30 deg. C. The RRS signal was detected at λ ex = λ em = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 μg mL -1 was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 μg mL -1 for oxytetracycline (OTC), 12.11-605.5 μg mL -1 for tetracycline (TC), 11.79-589.5 μg mL -1 for chlortetracycline (CTC) and 10.32-516.0 μg mL -1 for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability

  9. A reversed-phase high performance liquid chromatography coupled with resonance Rayleigh scattering detection for the determination of four tetracycline antibiotics

    Energy Technology Data Exchange (ETDEWEB)

    Lifeng, Wang [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Peng Jingdong [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)], E-mail: hxpengjd@swu.edu.cn; Limin, Liu [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2008-12-07

    A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm x 4.6 mm; 4 {mu}m) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min{sup -1}. Column temperature was 30 deg. C. The RRS signal was detected at {lambda}{sub ex} = {lambda}{sub em} = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 {mu}g mL{sup -1} was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 {mu}g mL{sup -1} for oxytetracycline (OTC), 12.11-605.5 {mu}g mL{sup -1} for tetracycline (TC), 11.79-589.5 {mu}g mL{sup -1} for chlortetracycline (CTC) and 10.32-516.0 {mu}g mL{sup -1} for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability.

  10. A modified HPLC method improves the simultaneous determination of plasma kynurenine and tryptophan concentrations in patients following maintenance hemodialysis

    Science.gov (United States)

    XIAO, CHENGGEN; CHEN, YUANHAN; LIANG, XINLING; XIE, ZHEN; ZHANG, MIN; LI, RUIZHAO; LI, ZHILIAN; FU, XIA; YU, XIYONG; SHI, WEI

    2014-01-01

    The ratio between plasma kynurenine (Kyn) and tryptophan (Trp) serves as a marker of indoleamine 2,3-dioxygenase, a critical immunomodulatory molecule. Simultaneous detection of the two markers may be performed using high-pressure liquid chromatography (HPLC). However, for uremic patients, the conventional detection method may be affected by a range of accumulated toxins. The current study aimed to establish a method for the simultaneous measurement of Kyn and Trp in patients following maintenance hemodialysis via HPLC-ultraviolet detection. The procedure involved the use of a SinoChrom ODS-BP C18 column (4.6×150 mm; inner diameter, 4.5 μm) and a mobile phase of 15 mmol/l sodium acetate acetic acid solution (containing 5% acetonitrile, pH 4.8). The modified method was verified using plasma samples from 10 healthy controls and 91 maintenance hemodialysis patients. The results demonstrated that the modified method was successful in simultaneously detecting the concentrations of Trp and Kyn in the healthy controls and maintenance hemodialysis patients. The method is simple, fast, accurate and suitable for clinical and research purposes in maintenance hemodialysis patients. PMID:24669249

  11. A reverse phased high-pressure liquid chromatographic method for the estimation of a poisonous matter in Strychnos nux-vomica

    Directory of Open Access Journals (Sweden)

    Achu Hashim

    2015-01-01

    Full Text Available Seeds of Strychnos nux-vomica were subjected to preliminary phytochemical tests and its presence was confirmed by thin layer chromatography (TLC method. The TLC profile of the methanolic extract of seeds of S. nux-vomica was developed using the solvent system toluene:chloroform:methanol in the ratio 8:2:1. The plate was observed in visible light after spraying with Dragendorff′s reagent (specific method. High-performance liquid chromatography (HPLC profile of the methanolic extracts of S. nux-vomica was developed, and the amount of strychnine seems to be 0.36% (w/w in the seeds. The TLC and HPLC profiles developed are very valuable for the identification of the original drug from their adulterants. The TLC profile identifies the presence of strychnine in the plant material. The quantification method for the strychnine in the seeds can be used for the quality standardization of the raw drug because the strychnine is reported to have some toxicity.

  12. Graphene/phase change material nanocomposites: light-driven, reversible electrical resistivity regulation via form-stable phase transitions.

    Science.gov (United States)

    Wang, Yunming; Mi, Hongyi; Zheng, Qifeng; Ma, Zhenqiang; Gong, Shaoqin

    2015-02-04

    Innovative photoresponsive materials are needed to address the complexity of optical control systems. Here, we report a new type of photoresponsive nanomaterial composed of graphene and a form-stable phase change material (PCM) that exhibited a 3 orders of magnitude change in electrical resistivity upon light illumination while retaining its overall original solid form at the macroscopic level. This dramatic change in electrical resistivity also occurred reversibly through the on/off control of light illumination. This was attributed to the reversible phase transition (i.e., melting/recrystallization) behavior of the microscopic crystalline domains present in the form-stable PCM. The reversible phase transition observed in the graphene/PCM nanocomposite was induced by a reversible temperature change through the on/off control of light illumination because graphene can effectively absorb light energy and convert it to thermal energy. In addition, this graphene/PCM nanocomposite also possessed excellent mechanical properties. Such photoresponsive materials have many potential applications, including flexible electronics.

  13. Solid cation exchange phase to remove interfering anthocyanins in the analysis of other bioactive phenols in red wine.

    Science.gov (United States)

    da Silva, Letícia Flores; Guerra, Celito Crivellaro; Klein, Diandra; Bergold, Ana Maria

    2017-07-15

    Bioactive phenols (BPs) are often targets in red wine analysis. However, other compounds interfere in the liquid chromatography methods used for this analysis. Here, purification procedures were tested to eliminate anthocyanin interference during the determination of 19 red-wine BPs. Liquid chromatography, coupled to a diode array detector (HPLC-DAD) and a mass spectrometer (UPLC-MS), was used to compare the direct injection of the samples with solid-phase extractions: reversed-phase (C18) and strong cation-exchange (SCX). The HPLC-DAD method revealed that, out of 13BPs, only six are selectively analyzed with or without C18 treatment, whereas SCX enabled the detection of all BPs. The recovery with SCX was above 86.6% for eight BPs. Moreover, UPLC-MS demonstrated the potential of SCX sample preparation for the determination of 19BPs. The developed procedure may be extended to the analysis of other red wine molecules or to other analytical methods where anthocyanins may interfere. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Stability-indicating HPLC-DAD methods for determination of two binary mixtures: Rabeprazole sodium-mosapride citrate and rabeprazole sodium-itopride hydrochloride.

    Science.gov (United States)

    El-Fatatry, Hamed M; Mabrouk, Mokhtar M; Hewala, Ismail I; Emam, Ehab H

    2014-08-01

    Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)-mosapride citrate (MR) and RZ-itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ-MR mixture consisted of acetonitrile: 0.025 M KH 2 PO 4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ-IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log  A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.

  15. A new method to describe two-phase solvent extraction based on net transport potential derived as linear combinations of forward and reverse constituents

    International Nuclear Information System (INIS)

    Nabeshima, Masahiro

    1998-01-01

    With the view to avoiding the difficulties encountered in estimating thermodynamic activities of the multiple chemical species in two-phase liquid system, a set of forward, reverse, net and total transport potentials are defined to represent the chemical state of a transferring solute during transient using bulk concentrations. The net transport potential corresponds to that in the conventional two-film model of diffusion-controlled processes. The overall driving forces of mass transport are redefined as the derivatives of the relevant transport potentials differentiated with respect to a state variable newly defined in terms of the bulk concentrations of the solute contained in both phases. Net and total quantities, i.e. transport potentials, overall driving forces and the molar fluxes are obtained as linear combinations of those for forward and reverse directions. The topical features presented by these quantities and their mutual relations are discussed in detail. The experimental new overall transport coefficient for U(VI) varied in accord with the changes in the theoretical net transport potential and overall driving force. The present method permits describing the extractive mass transport consistently both to forward and reverse directions of transport. (author)

  16. [Simultaneous determination of principal components and related substances of raw material drug of ammonium glycyrrhizinate by reversed-phase high performance liquid chromatography].

    Science.gov (United States)

    Zhao, Yanyan; Liu, Liyan; Han, Yuanyuan; Li, Yueqiu; Wang, Yan; Shi, Minjian

    2013-09-01

    An analytical method for the simultaneous determination of 18alpha-glycyrrhizic acid, 18beta-glycyrrhizinic acid, related substances A and B and drug quality standard by reversed-phase high performance liquid chromatography (RP-HPLC) was established. The assay was carried out on a Durashell-C18 column (250 mm x 4.6 mm, 5 microm) with 10 mmol/L ammonium perchlorate (the pH value was adjusted to 8.20 with ammonia)-methanol (48:52, v/v) as mobile phase at a flow rate of 0.80 mL/min, and the detection wavelength was set at 254 nm. The column temperature was 50 degrees C and the injection volume was 10 microL. Under the separation conditions, the calibration curves of the analytes showed good linearities within the mass concentrations of 0.50 -100 mg/L (r > 0.999 9). The detection limits for 18alpha-glycyrrhizic acid, 18beta-glycyrrhizinic acid, related substances A and B were 0.15, 0.10, 0.10, 0.15 mg/L, respectively. The average recoveries were between 97.32% and 99.33% (n = 3) with the relative standard deviations (RSDs) between 0.05% and 1.06%. The method is sensitive, reproducible, and the results are accurate and reliable. The method can be used for the determination of principal components and related substances of ammonium glycyrrhizinate for the quality control of raw material drug of ammonium glycyrrhizinate.

  17. Development and validation of a dissolution test with reversed-phase high performance liquid chromatographic analysis for Candesartan cilexetil in tablet dosage forms

    Directory of Open Access Journals (Sweden)

    Vairappan Kamalakkannan

    2016-09-01

    Full Text Available A simple, rapid, selective and reproducible reversed-phase high performance liquid chromatographic (RP-HPLC method has been developed and validated for the estimation of release of Candesartan cilexetil (CC in tablets. Analysis was performed on an Agilent, Zorbax C8 column (150mm × 4.6mm, 5μm with the mobile phase consisting of phosphate buffer (pH2.5–acetonitrile (15:85, v/v at a flow rate of 1.0mL/min. UV detection was performed at 215nm and the retention time for CC was 2.2. The calibration curve was linear (correlation coefficient = 1.000 in the selected range of analyte. The optimized dissolution conditions include the USP apparatus 2 at a paddle rotation rate of 50rpm and 900mL of phosphate buffer (pH7.2 with 0.03% of polysorbate 80 as dissolution medium, at 37.0 ± 0.5°C. The method was validated for precision, linearity, specificity, accuracy, limit of quantitation and ruggedness. The system suitability parameters, such as theoretical plate, tailing factor and relative standard deviation (RSD between six standard replicates were well within the limits. The stability result shows that the drug is stable in the prescribed dissolution medium. Three different batches (A, B and C of the formulation containing 8mg of Candesartan cilexetil was performed with the developed method and the results showed no significant differences among the batches.

  18. Stress degradation studies of Telmisartan and Metoprolol extended release tablets by a validated stability indicating reverse phase-high performance liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Kabeer Ahmed Shaikh

    2014-01-01

    Full Text Available Background and Aim: A sensitive reverse phase high-performance liquid chromatographic method has been developed for the simultaneous determination of Telimisartan and Metoprolol in tablet dosage form. Materials and Method: The chromatographic separation was achieved on Inertsil ODS 3V, 150 x 4.6 mm, 5μ analytical column. Mobile phase consisting of mobile phase A- 0.05M sodium dihydrogen phosphate buffer pH 3.0 and mobile phase B-Acetonitrile, with gradient program time in min /Mobile phase B% 0/22, 4/45, 6/45,18/22, 20/22. Detector was set at 222nm. Results and Conclusion: The described method shows excellent linearity over a range of 80-2 μg mL−1 for Telmisartan and 100-4 μg mL−1 for Metoprolol. The correlation coefficient for Telmisartan is 0.9998 and Metoprolol is 0.9999. The proposed method was found to be suitable for determination of Telmisartan and Metoprolol in tablet dosage form. Forced degradation of the drug product was conducted in accordance with the ICH guideline. Acidic, basic, hydrolytic, oxidative, thermal and photolytic degradation was used to assess the stability indicating power of the method. The drug product was found to be stable in acid, oxidation, thermal and photolytic stress condition and found degradation in base hydrolysis stress condition.

  19. Validation of histamine determination Method in yoghurt using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    M Jahedinia

    2014-02-01

    Full Text Available Biogenic amines are organic, basic nitrogenous compounds of low molecular weight that are mainly generated by the enzymatic decarboxylation of amino acids by microorganisms. Dairy products are among the foods with the highest amine content. A wide variety of methods and procedures for determination of histamine and biogenic amines have been established. Amongst, HPLC method is considered as reference method. The aim of this study was to validate Reversed Phase HPLC method determination of histamine in yoghurt. The mobile phase consisted of acetonitrile/water (18:88 v/v and the flow rate was set at 0.5 ml/min using isocratic HPLC. Detection was carried out at 254 nm using UV-detector. Calibration curve that was constructed using peak area of standards was linear and value of correlation coefficient (r2 was estimated at 0.998. Good recoveries were observed for histamine under investigation at all spiking levels and average of recoveries was 84%. The RSD% value from repeatability test was found to be %4.4. Limit of detection and limit of quantitation were 0.14 and 0.42 µ/ml, respectively. The results of validation tests showed that the method is reliable and rapid for quantification of histamine in yoghurt.

  20. Three-phase hollow-fiber liquid-phase microextraction combined with HPLC-UV for the determination of isothiazolinone biocides in adhesives used for food packaging materials.

    Science.gov (United States)

    Rosero-Moreano, Milton; Canellas, Elena; Nerín, Cristina

    2014-02-01

    The present study deals with the development of a liquid microextraction procedure for enhancing the sensitivity of the determination of 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one in adhesives. The procedure involves a three-phase hollow-fiber liquid-phase microextraction using a semipermeable polypropylene membrane, which contained 1-octanol as the organic phase in the pores of the membrane. The donor and acceptor phases are aqueous acidic and alkaline media, respectively, and the final liquid phase (acceptor) is analyzed by HPLC coupled with diode array detection. The most appropriate conditions were extraction time 20 min, stirring speed 1400 rpm, extraction temperature 50°C. The quantification limits of the method were 0.123 and 0.490 μg/g for 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one, respectively. Three different adhesive samples were successfully analyzed. The procedure was compared to direct analysis using ultra high pressure liquid chromatography coupled with TOF-MS, where the identification of the compounds and the quantification values were confirmed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    International Nuclear Information System (INIS)

    Park, Sang Il; Park, Sang Cheol; Kim, So Ra; Jang, Young Pyo

    2016-01-01

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E

  2. Two-step Purification Method for Aging Pigments A2E and Iso-A2E Using Medium Pressure Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Il; Park, Sang Cheol [Kyunghee Univ., Seoul (Korea, Republic of); Kim, So Ra; Jang, Young Pyo [Seoul National Univ., Seoul (Korea, Republic of)

    2016-09-15

    A newly modified method for the efficient purification of A2E and iso-A2E using reverse phase silica gel resin with medium pressure liquid chromatography (MPLC) was suggested. MPLC is one of the various preparative column chromatography techniques and separation under pressure renders the use of smaller particle size resins possible and increases the diversity of available stationary phases. A simplified two-step purification method was developed for the purification of aging pigments in eye, A2E and iso-A2E. With simple two-step elution of mobile phase in reverse phase MPLC, A2E and iso-A2E were successfully purified with great efficiency compare with previous column chromatography and HPLC method. This method provides more simple, convenient, cost-effective, and less time-consuming procedure for mass purification of aging pigments A2E and iso-A2E.

  3. HPLC determination of caffeine in coffee beverage

    Science.gov (United States)

    Fajara, B. E. P.; Susanti, H.

    2017-11-01

    Coffee is the second largest beverage which is consumed by people in the world, besides the water. One of the compounds which contained in coffee is caffeine. Caffeine has the pharmacological effect such as stimulating the central nervous system. The purpose of this study is to determine the level of caffeine in coffee beverages with HPLC method. Three branded coffee beverages which include in 3 of Top Brand Index 2016 Phase 2 were used as samples. Qualitative analysis was performed by Parry method, Dragendorff reagent, and comparing the retention time between sample and caffeine standard. Quantitative analysis was done by HPLC method with methanol-water (95:5v/v) as mobile phase and ODS as stationary phasewith flow rate 1 mL/min and UV 272 nm as the detector. The level of caffeine data was statistically analyzed using Anova at 95% confidence level. The Qualitative analysis showed that the three samples contained caffeine. The average of caffeine level in coffee bottles of X, Y, and Z were 138.048 mg/bottle, 109.699 mg/bottle, and 147.669 mg/bottle, respectively. The caffeine content of the three coffee beverage samples are statistically different (pcoffee beverage samples were not meet the requirements set by the Indonesian Standard Agency of 50 mg/serving.

  4. Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.

    Science.gov (United States)

    Valto, Piia; Knuutinen, Juha; Alén, Raimo

    2011-04-01

    A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  6. A rapid and simple determination of A77 1726 in human serum by high-performance liquid chromatography and its application for optimization of leflunomide therapy

    NARCIS (Netherlands)

    van Roon, EN; Yska, JP; Raemaekers, J; Jansen, TLTA; van Wanrooy, M; Brouwers, JRBJ

    2004-01-01

    Leflunomide is a disease-modifying antirheumatic drug, which is bioactivated by fort-nation of A77 1726. In this study a rapid and simple quantitative assay using a reversed phase HPLC-UV method is validated for detection of A77 1726 in human serum. The HPLC-UV method uses a mobile phase consisting

  7. Method 447.0 - Determination of Chlorophylls a and b and Identification of Other Pigments of Interest in Marine and Freshwater Algae Using High Performance Liquid Chromatography with Visible Wavelength Detection

    Science.gov (United States)

    This method provides a procedure for determination of chlorophylls a (chl a) and b (chl b) found in marine and freshwater phytoplankton. Reversed phase high performance liquid chromatography (HPLC) with detection at 440 nm is used to separate the pigments from a complex pigment ...

  8. Stability-indicating RP-HPLC method for simultaneous determination of gatifloxacin and flurbiprofen in binary combination

    Directory of Open Access Journals (Sweden)

    Islam Ullah Khan

    2014-04-01

    Full Text Available A stability-indicating RP-HPLC method is presented for determination of gatifloxacin and flurbiprofen in binary combination. Gatifloxacin, flurbiprofen and their degradation products were detected at 254 nm using a BDS Hypersil C8 (250 X 4.6 mm, 5 µm column and mixture of 20 mM phosphate buffer (pH 3.0 and methanol 30:70 v/v as mobile phase. Response was linear over the range of 15-105 mg mL-1 for gatifloxacin (r² > 0.998 and of 1.5-10.5 mg mL-1 for flurbiprofen (r² > 0.999. The developed method efficiently separated the analytical peaks from degradation products (peak purity index > 0.9999. The method developed can be applied successfully for determination of gatifloxacin and flurbiprofen in human serum, urine, pharmaceutical formulations, and their stability studies.

  9. Two complementary reversed-phase separations for comprehensive coverage of the semipolar and nonpolar metabolome.

    Science.gov (United States)

    Naser, Fuad J; Mahieu, Nathaniel G; Wang, Lingjue; Spalding, Jonathan L; Johnson, Stephen L; Patti, Gary J

    2018-02-01

    Although it is common in untargeted metabolomics to apply reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) methods that have been systematically optimized for lipids and central carbon metabolites, here we show that these established protocols provide poor coverage of semipolar metabolites because of inadequate retention. Our objective was to develop an RPLC approach that improved detection of these metabolites without sacrificing lipid coverage. We initially evaluated columns recently released by Waters under the CORTECS line by analyzing 47 small-molecule standards that evenly span the nonpolar and semipolar ranges. An RPLC method commonly used in untargeted metabolomics was considered a benchmarking reference. We found that highly nonpolar and semipolar metabolites cannot be reliably profiled with any single method because of retention and solubility limitations of the injection solvent. Instead, we optimized a multiplexed approach using the CORTECS T3 column to analyze semipolar compounds and the CORTECS C 8 column to analyze lipids. Strikingly, we determined that combining these methods allowed detection of 41 of the total 47 standards, whereas our reference RPLC method detected only 10 of the 47 standards. We then applied credentialing to compare method performance at the comprehensive scale. The tandem method showed more than a fivefold increase in credentialing coverage relative to our RPLC benchmark. Our results demonstrate that comprehensive coverage of metabolites amenable to reversed-phase separation necessitates two reconstitution solvents and chromatographic methods. Thus, we suggest complementing HILIC methods with a dual T3 and C 8 RPLC approach to increase coverage of semipolar metabolites and lipids for untargeted metabolomics. Graphical abstract Analysis of semipolar and nonpolar metabolites necessitates two reversed-phase chromatography (RPLC) methods, which extend metabolome coverage more

  10. HPLC a možnost jejího využití při vzdělávání budoucích učitelů chemie

    OpenAIRE

    Gabriel, Štěpán

    2017-01-01

    This diploma thesis is focused on theoretical and practical aspects of High performance liquid chromatography (HPLC). This method is introduced as one of the most frequently used current analytical methods. The theoretical part of thesis is focused on instrumentation of HPLC and particular components of HPLC analytical system. The most often used mobile phases and static phases are described as well. Based on these theoretical aspects, laboratory exercise using HPLC for future teachers is des...

  11. Development and validation of analytical method for the estimation of nateglinide in rabbit plasma

    Directory of Open Access Journals (Sweden)

    Nihar Ranjan Pani

    2012-12-01

    Full Text Available Nateglinide has been widely used in the treatment of type-2 diabetics as an insulin secretogoga. A reliable, rapid, simple and sensitive reversed-phase high performance liquid chromatography (RP-HPLC method was developed and validated for determination of nateglinide in rabbit plasma. The method was developed on Hypersil BDSC-18 column (250 mm×4.6 mm, 5 mm using a mobile phase of 10 mM phosphate buffer (pH 2.5 and acetonitrile (35:65, v/v. The elute was monitored with the UV–vis detector at 210 nm with a flow rate of 1 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of nateglinide and internal standard (gliclazide were 9.608 min and 11.821 min respectively. The developed RP-HPLC method can be successfully applied to the quantitative pharmacokinetic parameters determination of nateglinide in rabbit model. Keywords: HPLC, Nateglinide, Rabbit plasma, Pharmacokinetics

  12. Modified saponification and HPLC methods for analyzing carotenoids from the retina of quail: implications for its use as a nonprimate model species.

    Science.gov (United States)

    Toomey, Matthew B; McGraw, Kevin J

    2007-09-01

    To investigate carotenoid content in the retina of Japanese quail (Coturnix japonica), for comparison with carotenoids in human retina, and to assess the effects of different saponification procedures on the recovery of quail retinal carotenoids. Extracted retinal carotenoids were saponified with methods adapted from recent studies, then identified and quantified with reverse-phase high-performance liquid chromatography (HPLC). To assess the effects of saponification conditions on carotenoid recovery from quail retina, we varied base concentration and the total time of saponification across a wide range and again used HPLC to compare carotenoid concentrations among conditions. Astaxanthin and galloxanthin were the dominant carotenoids recovered in the quail retina, along with smaller amounts of five other carotenoids (lutein, zeaxanthin, 3'-epilutein, epsilon-carotene, and an unidentified carotenoid). Astaxanthin was sensitive to saponification conditions; recovery was poor with strong bases (0.2 and 0.5 M KOH) and best with weak bases (0.01 and 0.2 M KOH). In contrast, xanthophyll carotenoids (galloxanthin, zeaxanthin, lutein, 3'-epilutein, and the unknown) were best recovered with strong base after 6 hours of saponification at room temperature. The recovery of epsilon-carotene was not affected by saponification conditions. Separate chemical hydrolysis procedures--using a strong base to recover xanthophylls and a weak base to recover astaxanthin--should be used for maximizing recovery of quail retinal carotenoids. Because the dominant carotenoids in quail retina are absent in human retina, and because of their different packaging (e.g., esterified in oil droplets) and light-absorbance properties compared with xanthophylls in the human eye, use of the quail as a model organism for studying human retinal carotenoids should be approached with caution.

  13. Supercritical fluid reverse micelle separation

    Science.gov (United States)

    Fulton, J.L.; Smith, R.D.

    1993-11-30

    A method of separating solute material from a polar fluid in a first polar fluid phase is provided. The method comprises combining a polar fluid, a second fluid that is a gas at standard temperature and pressure and has a critical density, and a surfactant. The solute material is dissolved in the polar fluid to define the first polar fluid phase. The combined polar and second fluids, surfactant, and solute material dissolved in the polar fluid is maintained under near critical or supercritical temperature and pressure conditions such that the density of the second fluid exceeds the critical density thereof. In this way, a reverse micelle system defining a reverse micelle solvent is formed which comprises a continuous phase in the second fluid and a plurality of reverse micelles dispersed in the continuous phase. The solute material is dissolved in the polar fluid and is in chemical equilibrium with the reverse micelles. The first polar fluid phase and the continuous phase are immiscible. The reverse micelles each comprise a dynamic aggregate of surfactant molecules surrounding a core of the polar fluid. The reverse micelle solvent has a polar fluid-to-surfactant molar ratio W, which can vary over a range having a maximum ratio W[sub o] that determines the maximum size of the reverse micelles. The maximum ratio W[sub o] of the reverse micelle solvent is then varied, and the solute material from the first polar fluid phase is transported into the reverse micelles in the continuous phase at an extraction efficiency determined by the critical or supercritical conditions. 27 figures.

  14. Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography.

    Science.gov (United States)

    Mallik, Abul K; Noguchi, Hiroki; Rahman, Mohammed Mizanur; Takafuji, Makoto; Ihara, Hirotaka

    2018-06-22

    The synthesis of a new alternating copolymer-grafted silica phase is described for the separation of shape-constrained isomers of polycyclic aromatic hydrocarbons (PAHs) and tocopherols in reversed-phase high-performance liquid chromatography (RP-HPLC). Telomerization of the monomers (octadecyl acrylate and N-methylmaleimide) was carried out with a silane coupling agent; 3-mercaptopropyltrimethoxysilane (MPS), and the telomer (T) was grafted onto porous silica surface to prepare the alternating copolymer-grafted silica phase (Sil-alt-T). The new hybrid material was characterized by elemental analyses, diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy, and solid-state 13 C and 29 Si cross-polarization magic-angle spinning (CP/MAS) NMR spectroscopy. The results of 13 C CP/MAS NMR demonstrated that the alkyl chains of the grafted polymers in Sil-alt-T remained disordered, amorphous, and mobile represented by gauche conformational form. Separation abilities and molecular-shape selectivities of the prepared organic phase were evaluated by the separation of PAHs isomers and Standard Reference Material 869b, Column Selectivity Test Mixture for Liquid Chromatography, respectively and compared with commercially available octadecylsilylated silica (ODS) and C 30 columns as well as previously reported alternating copolymer-based column. The effectiveness of this phase is also demonstrated by the separation of tocopherol isomers. Oriented functional groups along the polymer main chains and cavity formations are investigated to be the driving force for better separation with multiple-interactions with the solutes. One of the advantages of the Sil-alt-T phase to that of the previously reported phase is the synthesis of the telomer first and then immobilized onto silica surface. In this case, the telomer was characterized easily with simple spectroscopic techniques and the molecular mass and polydispersity index of the telomer were determined by size exclusion

  15. Mixed-mode reversed phase/positively charged repulsion chromatography for intact protein separation.

    Science.gov (United States)

    Ding, Ling; Guo, Zhimou; Hu, Zhuo; Liang, Xinmiao

    2017-05-10

    A mixed-mode reversed phase/positively charged repulsion stationary phase C8PN composed of octyl and amino group has been developed for separation of intact protein. Before the separation of proteins, a set of probe compounds were employed to evaluate the chromatographic properties of C8PN, demonstrating typical reversed phase/positively charged repulsion interaction on this stationary phase as estimated. Then the new C8PN stationary phase was used to separate a standard protein mixture on the reversed phase mode. Compared with a commercial C4 stationary phase, it showed different selectivity for some proteins. In order to better understand the properties of C8PN, the effect of acetonitrile content was investigated based on retention equation. Higher values of the equation parameters on C8PN demonstrated that the protein retentions were more sensitive to the change of acetonitrile content. Besides, the influences of buffer salt additives on the protein retentions were also studied. The retention factors of the proteins got larger with the increase of buffer salt concentration, which confirmed the positively charged repulsion interaction on the column. Finally, the C8PN was further applied to separate oxidized- and reduced- forms of Recombinant Human Growth Hormone. Our study indicated the advantages and application potential of mixed-mode reversed phase/positively charged repulsion stationary phase for intact protein separation. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  17. A time-reversal invariant topological phase at the surface of a 3D topological insulator

    International Nuclear Information System (INIS)

    Bonderson, Parsa; Nayak, Chetan; Qi, Xiao-Liang

    2013-01-01

    A 3D fermionic topological insulator has a gapless Dirac surface state protected by time-reversal symmetry and charge conservation symmetry. The surface state can be gapped by introducing ferromagnetism to break time-reversal symmetry, introducing superconductivity to break charge conservation, or entering a topological phase. In this paper, we construct a minimal gapped topological phase that preserves both time-reversal and charge conservation symmetries and supports Ising-type non-Abelian anyons. This phase can be understood heuristically as emerging from a surface s-wave superconducting state via the condensation of eight-vortex composites. The topological phase inherits vortices supporting Majorana zero modes from the surface superconducting state. However, since it is time-reversal invariant, the surface topological phase is a distinct phase from the Ising topological phase, which can be viewed as a quantum-disordered spin-polarized p x + ip y superconductor. We discuss the anyon model of this topological phase and the manner in which time-reversal symmetry is realized in it. We also study the interfaces between the topological state and other surface gapped phases. (paper)

  18. Comparison of calorimetric and HPLC methods in measuring nitrate content of meat products: An economic evaluation

    Directory of Open Access Journals (Sweden)

    M moradi

    2014-02-01

    Full Text Available Nitrate is a flavors compound, color stabilizer and growth inhibitor of anaerobic microorganisms in meat products. High concentration of nitrate in food can cause methaemoglobinaemia and is recognized as carcinogenic. Therefore, accurate determination of nitrate is crucial to ensure consumers’ health. Regularly, nitrate is estimated by colorimetric and HPLC methods. In measurement of nitrate, the efficiency, accuracy, speed and amount of material are important from economical point of view. In this study, the cost of initial investment, staff, consumable material and equipments used by the two methods were calculated and finally Net Present Value (NPV was estimated for each of them. The rate of interest was considered from 4 until 30%. According to the results the amount of initial investment, annual cost of staff and consumable materials for colorimetric method were determined as 274000000, 379080000 and 214289130 Rials, respectively. These costs for HPLC method were 342000000, 252720000 and 7633080 Rials, respectively. NPV in minimum and maximum rates of interest (4 and 30% for colorimetric method were 8368344000 and 2242330000 Rials and for HPLC method were estimated at 4035848000 and 1207544000 Rials. As a consequence, HPLC is more economical and could be recommended for the routine measurement of nitrate in of food safety laboratories.

  19. A validated HPLC determination of the flavone aglycone diosmetin in human plasma.

    Science.gov (United States)

    Kanaze, Feras Imad; Bounartzi, Melpomeni I; Niopas, Ioannis

    2004-12-01

    Diosmetin, 3',5,7-trihydroxy-4'-methoxy flavone, is the aglycone of the flavonoid glycoside diosmin that occurs naturally in foods of plant origin. Diosmin exhibits antioxidant and anti-inflammatory activities, improves venous tone and it is used for the treatment of chronic venous insufficiency. Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the determination of diosmetin in human plasma was developed and validated. Diosmetin and the internal standard 7-ethoxycoumarin were isolated from plasma by liquid-liquid extraction and separated on a C8 reversed-phase column with methanol-water-acetic acid (55:43:2, v/v/v) as the mobile phase at 43 degrees C. Peaks were monitored at 344 nm. The method was linear in the 10-300 ng/mL concentration range (r > 0.999). Recovery for diosmetin and internal standard was greater than 89.7 and 86.8%, respectively. Intra-day and inter-day precision for diosmetin ranged from 1.6 to 4.6 and from 2.2 to 5.3%, respectively, and accuracy was better than 97.9%. Copyright 2004 John Wiley & Sons, Ltd.

  20. Determination of La and Nd by thermal ionization mass spectrometry (TIMS) pre-separated by high performance liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Jaison, P.G.; Raut, N.M.; Parab, A.R.; Khodade, P.S.; Govindan, R.; Aggarwal, S.K.

    2003-01-01

    Determination of La and Nd by TIMS is required for accurate determination of burn-up of nuclear fuels. During their thermal ionization mass spectrometric (TIMS) analysis, 138 Ce and 142 Ce show spectroscopic isobaric interferences at 138 La and 142 Nd, respectively. Hence, it is essential to remove Ce from La and Nd for their accurate isotopic composition determination. Reversed phase high performance liquid chromatography (HPLC) is a promising technique for rapid and effective separation

  1. Magnetic molecularly imprinted polymer nanoparticles for the solid-phase extraction of paracetamole from plasma samples, followed its determination by HPLC

    International Nuclear Information System (INIS)

    Azodi-Deilami, Saman; Najafabadi, Alireza Hassani; Asadi, Ebadullah; Abdouss, Majid; Kordestani, Davood

    2014-01-01

    We are presenting magnetic molecularly imprinted polymer nanoparticles (m-MIPs) for solid-phase extraction and sample clean-up of paracetamole. The m-MIPs were prepared from magnetite (Fe 3 O 4 ) as the magnetic component, paracetamole as the template, methacrylic acid as a functional monomer, and 2-(methacrylamido) ethyl methacrylate as a cross-linker. The m-MIPs were then characterized by transmission electron microscopy, FT-IR spectroscopy, X-ray diffraction and vibrating sample magnetometry. The m-MIPs were applied to the extraction of paracetamole from human blood plasma samples. Following its elution from the column loaded with the m-MIPs with an acetonitrile-buffer (9:1) mixture, it was submitted to HPLC analysis. Paracetamole can be quantified by this method in the 1 μg L −1 to 300 μg L −1 concentration range. The limit of detection and limit of quantification in plasma samples are 0.17 and 0.4 μg L −1 . The preconcentration factor of the m-MIPs is 40. The HPLC method shows good precision (4.5 % at 50 μg L −1 levels) and recoveries (between 83 and 91 %) from spiked plasma samples. (author)

  2. Development and Validation of RP-HPLC Method for the Determination of Adefovir Dipivoxil in Bulk and in Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    Zaheer Ahmed

    2009-01-01

    Full Text Available A rapid and sensitive RP-HPLC method with UV detection (262 nm for routine analysis of adefovir dipivoxil in bulk and in pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and phosphate buffer (50:50, v/v with flow rate 1.0 mL min-l. In the range of 5.0-100 µg/mL, the linearity of adefovir dipivoxil shows a correlation co-efficient of 0.9999. The proposed method was validated by determining sensitivity accuracy, precision, robustness stability, specificity, selectivity and system suitability parameters.

  3. Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed.

    Science.gov (United States)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2012-05-04

    Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. [Determination of genkwanin in flos Genkwa by HPLC].

    Science.gov (United States)

    Zhang, B; Yuan, S; Xia, K

    1996-04-01

    In this paper, the method for determining genkwanin in Flos Genkwa was established by HPLC. Detected at 332nm on a Lichrosorb 5 RP-18 column with a mobile phase of methanol-water-acetic acid (65:35:5), the content of genkwanin in Flos Genkwa was determined to be 0.16%. The recovery rate was 95.46% and RSD 1.15%.

  5. Quantitative determination of quinolones residues in milk by HPLC-FLD

    Directory of Open Access Journals (Sweden)

    Marilena Gili

    2012-10-01

    Full Text Available Veterinary drugs have become an integral part of the livestock production and play an important role in maintenance of animal welfare. The use of veterinary medicines may be cause of the presence of drug residues in animal food products if appropriate withdrawal periods are not respected or if contaminated feeds are used. This work presents the development of an HPLC-FLD method for the quantitative de-tection of eight quinolones – norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, oxolinic acid, nalidixic acid, flumequine– in bovine milk. After deproteination and extraction with a metaphos-phoric acid 1% w/v / methanol / acetonitrile (60/20/20 v/v/v solution, the sample is partially evaporated and cleaned up on a reversed phase SPE cartridge.The extract is analyzed using an high performance liquid chromatograph with fluorescence detector. Mean recovery ranged between 65% - 88%. All the an-alytes can be identified and quantified in the concentration range 15 - 60 μg/Kg for danofloxacin and 25 - 150 μg/Kg for the other quinolones.

  6. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  7. Assessment of radiochemical purity of [18F]fludeoxyglucose by high pressure liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Lacerda, Aline E.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z.

    2011-01-01

    The quality control of [ 18 F]fludeoxyglucose ( 18 FDG) has received attention due to its increasing clinical use. Although the quality requirements of 18 FDG are established in various pharmacopoeia, the suitability of all testing methods used should be verified under actual conditions of use and documented. The aim of this study was to develop a high pressure liquid chromatography (HPLC) method for radiochemical purity evaluation of 18 FDG, based on pharmacopoeia references, and to verify its suitability for routine quality control in our centre. HPLC analysis was performed with an Agilent HPLC. 18 FDG and impurities were separated on an anion-exchange column by isocratic elution with 0.1 M NaOH as the mobile phase. Detection was accomplished with refractive index and NaI (Tl) scintillation detectors. The flow rate of the mobile phase was set at 0.8 mL/min and the column temperature was kept at 35 deg C. Specificity, linearity, precision and robustness were assessed to verify if the method was adequate for its intended purpose. Retention time of 18 FDG was not affected by the presence of other components of the formulation and a good peak resolution was achieved. The analytical curve of 18 FDG was linear, with a correlation coefficient value of 0.9995. Intraday repeatable precision, reported as the relative standard deviation, was 0.11%. Analytical procedure remained unaffected by small variations in mobile phase flow rate. Results evidenced that HPLC is suitable for radiochemical purity evaluation of 18 FDG, considering operational conditions of our laboratory. (author)

  8. Salting-Out Assisted Liquid-Liquid Extraction for Quantification of Febuxostat in Plasma Using RP-HPLC and Its Pharmacokinetic Application.

    Science.gov (United States)

    Tandel, Devang; Shah, Purvi; Patel, Kalpana; Thakkar, Vaishali; Patel, Kirti; Gandhi, Tejal

    2016-11-01

    A rapid and sensitive reversed-phase high-performance liquid chromatography (HPLC) method using novel salting-out assisted liquid-liquid extraction technique has been developed for the quantitative determination of febuxostat (FEB), used for the treatment of gout, in rat plasma. The method was validated according to US FDA guideline. Separation was achieved using a Phenomenex Luna-C 18 (250 × 4.60 mm, 5 µm) column and mobile phase composed of potassium dihydrogen orthophosphate buffer 25 mM, adjusted to pH 6.8 with triethylamine:methanol in a ratio of 35:65 (v/v) showing retention time 5.56 and 8.86 min for FEB and internal standard, respectively. The optimal salting-out parameters; 1 mL of acetonitrile and 200 µL of 2 M ammonium acetate salt showed extraction recovery >90% for FEB from plasma. This extraction procedure afforded clear samples resulting in convenient and cost-saving procedure and showed good linear relationship (r > 0.9997) between peak area ratio and concentration from 0.3 to 20 µg/mL. The results of pharmacokinetic study showed that absorption profile of spherical agglomerate of FEB compared to marketed formulation was higher indicating greater systemic absorption. In conclusion, the developed SALLE-HPLC method with simple ultraviolet detection offered a number of advantages including good quantitative ability, wide linear range, high recovery, short analysis time as well as low cost. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Determination of impurities and degradation products from veterinary medicinal products by HPLC method

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean

    2014-06-01

    Full Text Available The organic or inorganic impurities in the veterinary medicinal product can derive from starting materials, manufacturing process, incomplete purification, inappropriate storage. The acceptable levels of impurities in pharmaceuticals are estimated by comparison with standard solutions, according to the appropriate monographs. Forced degradation studies determine the stability of the method of dosage for the active compounds and for the entire finished product under excessive accelerated degradation conditions. They also provide information on degradation pathways and selectivity of analytical methods applied. The information provided by the degradation studies on the active compound and finished pharmaceutical product should demonstrate the specificity of the analytical method regarding impurities. Forced degradation studies should demonstrate that the impurities and degradation products generated do not interfere with the active compound. The current forced degradation methods consist of acid hydrolysis, basic hydrolysis, oxidation, exposure of the medicinal product to temperature and light. HPLC methods are an integral analytical instrument for the analysis of the medicinal product. The HPLC method should be able to separate, detect and quantify various specific degradation products that can appear after manufacture or storage of the medicinal product, as well as new elements appearing after synthesis. FDA and ICH guidelines recommend the enclosure of the results, including the chromatograms specific to the forced degradation-subjected medicinal product, in the documentation for marketing authorization. Using HPLC methods in forced degradation studies on medicinal products provides relevant information on the method of determination for the formulation of the medicinal product, synthesis product, packaging methods and storage.

  10. Stability Indicating HPLC Method for the Determination of Chiral Purity of R-(-)-5-[2-aminopropyl]-2-methoxybenzene Sulfonamide

    OpenAIRE

    Kasawar, G. B.; Farooqui, M. N.

    2009-01-01

    A chiral reverse phase liquid chromatographic method was developed for the enantiomeric resolution of racemic mixture of (-)-5-[2-aminopropyl]-2-methoxybenzene sulfonamide in bulk drug. The enantiomeric separation of sulfonamide was resolved on a Crownpak CR (+) column using perchloric acid buffer of pH 1.0 as mobile phase and with UV detection at 226 nm. The method is validated and proved to be robust. The limit of detection and quantification of S (-)-(5)-[2-aminopropyl]-2-methoxyben...

  11. Separation of Chloroplast Pigments Using Reverse Phase Chromatography.

    Science.gov (United States)

    Reese, R. Neil

    1997-01-01

    Presents a protocol that uses reverse phase chromatography for the separation of chloroplast pigments. Provides a simple and relatively safe procedure for use in teaching laboratories. Discusses pigment extraction, chromatography, results, and advantages of the process. (JRH)

  12. Analysis of quaternary ammonium and phosphonium ionic liquids by reversed-phase high-performance liquid chromatography with charged aerosol detection and unified calibration.

    Science.gov (United States)

    Stojanovic, Anja; Lämmerhofer, Michael; Kogelnig, Daniel; Schiesel, Simone; Sturm, Martin; Galanski, Markus; Krachler, Regina; Keppler, Bernhard K; Lindner, Wolfgang

    2008-10-31

    Several hydrophobic ionic liquids (ILs) based on long-chain aliphatic ammonium- and phosphonium cations and selected aromatic anions were analyzed by reversed-phase high-performance liquid chromatography (RP-HPLC) employing trifluoroacetic acid as ion-pairing additive to the acetonitrile-containing mobile phase and adopting a step-gradient elution mode. The coupling of charged aerosol detection (CAD) for the non-chromophoric aliphatic cations with diode array detection (DAD) for the aromatic anions allowed their simultaneous analysis in a set of new ILs derived from either tricaprylmethylammonium chloride (Aliquat 336) and trihexyltetradecylphosphonium chloride as precursors. Aliquat 336 is a mix of ammonium cations with distinct aliphatic chain lengths. In the course of the studies it turned out that CAD generates an identical detection response for all the distinct aliphatic cations. Due to lack of single component standards of the individual Aliquat 336 cation species, a unified calibration function was established for the quantitative analysis of the quaternary ammonium cations of the ILs. The developed method was validated according to ICH guidelines, which confirmed the validity of the unified calibration. The application of the method revealed molar ratios of cation to anion close to 1 indicating a quantitative exchange of the chloride ions of the precursors by the various aromatic anions in the course of the synthesis of new ILs. Anomalies of CAD observed for the detection of some aromatic anions (thiosalicylate and benzoate) are discussed.

  13. Micellar HPLC and derivative spectrophotometric methods for the simultaneous determination of fluconazole and tinidazole in pharmaceuticals and biological fluids.

    Science.gov (United States)

    Belal, F; Sharaf El-Din, M K; Eid, M I; El-Gamal, R M

    2014-04-01

    Micellar high-performance liquid chromatography (HPLC) and first-derivative ultraviolet spectrophotometry were used to simultaneously determine fluconazole (FLZ) and tinidazole (TNZ) in combined pharmaceutical dosage forms. The derivative procedure is based on the linear relationship between the drug concentration and the first derivative amplitudes at 220 and 288 nm for FLZ and TNZ, respectively. The calibration graphs were linear in the range of 1.5-9.0 µg/mL for FLZ and 10.0-60.0 µg/mL for TNZ. Furthermore, an HPLC procedure with ultraviolet detection at 210 nm was developed. For the HPLC procedure, good chromatographic separation was achieved using an ODS C18 column (250 × 4.6 mm i.d.). The mobile phase containing 0.15M sodium dodecyl sulphate, 0.3% triethylamine and 12% n-propanol in 0.02M orthophosphoric acid at pH 5.5 was pumped at a flow rate of 1 mL/min. Indapamide was used as an internal standard. The method showed good linearity over the concentration ranges of 1.5-30.0 and 10.0-200.0 µg/mL, with limits of detection of 0.36 and 2.70 µg/mL and limits of quantification of 1.1 and 8.2 µg/mL for FLZ and TNZ, respectively. The suggested methods were successfully applied for the simultaneous analysis of the drugs in their laboratory prepared mixture, co-formulated tablet and single dosage forms. Moreover the second method was also extended to the determination of the drugs in biological fluids.

  14. Separating DDTs in edible animal fats using matrix solid-phase dispersion extraction with activated carbon filter, Toyobo-KF.

    Science.gov (United States)

    Furusawa, Naoto

    2006-09-01

    A technique is presented for the economical, routine, and quantitative analysis of contamination by dichloro-diphenyl-trichloroethanes (DDTs) [pp'-DDT, pp'-dichlorodiphenyl dichloroethylene, and pp'-dichlorodiphenyl dichloreothane in beef tallow and chicken fat samples, based on their separation using matrix solid-phase dispersion (MSPD) extraction with Toyobo-KF, an activated carbon fiber. Toyobo-KF is a newly applied MSPD sorbent, and it is followed by reversed-phase high-performance liquid chromatography (HPLC) with a photodiode array detector. The resulting analytical performance parameters [recoveries of spiked DDTs (0.1, 0.2, and 0.4 microg/g) > or = 81%, with relative standard deviations of < or = 8% (n = 5), and quantitation limits < or = 0.03 microg/g], with minimal handling and cost-efficiency, indicate that the present MSPD-HPLC method may be a useful tool for routine monitoring of DDT contamination in meat.

  15. Enantiomeric separation of iridium (III) complexes using HPLC chiral stationary phases based on amylose derivatives

    International Nuclear Information System (INIS)

    Kim, Hee Eun; Seo, Na Hyeon; Hyun, Myung Ho

    2016-01-01

    Cyclometalated iridium (III) complexes formed with three identical cyclometalating (C-N) ligands (homoleptic) or formed with two cyclometalating (C-N) ligands and one ancillary (LX) ligand (heteroleptic) have been known as highly phosphorescent materials and, thus, they have been utilized as efficient phosphorescent dopants in organic light emitting diodes (OLEDs) 1–3 or as effective phosphorescent chemosensors. 4–7 Cylometalated iridium (III) complexes are chiral compounds consisting of lambda (Λ, left-handed) and delta (Δ, right-handed) isomers. Racemic cyclometa- lated iridium (III) complexes emit light with no net polarization, but optically active cyclometalated iridium (III) complexes emit circularly polarized light. 8,9 Circularly polarized light can be used in various fields including highly efficient three dimensional electronic devices, photo nic devices for optical data storage, biological assays, and others. 8,9 In order to obtain optically active cylometalated iridium (III) complexes and to determine the enantiomeric composition of optically active cylometalated iridium (III) complexes, liquid chromatogr aphic enantiomer separation method on chiral stationary phases (CSPs) has been used. For example, Okamoto and coworkers first reported the high performance liquid chromatographic (HPLC) direct enantiomeric separation of two homoleptic cylometalated iridium (III) complexes on immobilized amylose tris(3,5- dimethylphenylcarbamate) (Chiralpak IA), coated cellulose tris(3,5-dimethylphenylcarbamate) (Chiralc el OD), and coated cellulose tris(4-methylbenzoate) (Chiralce l OJ). 10 Supercritical fluid chromatography (SFC) was also used by Bernhard and coworkers for the enantiomeric separation of cylometalated iridium (III) complexes on coated amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD-H). 8 However, the general use of the HPLC method for the direct enantiomeric separation of homoleptic

  16. Enantiomeric separation of iridium (III) complexes using HPLC chiral stationary phases based on amylose derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee Eun; Seo, Na Hyeon; Hyun, Myung Ho [Dept. of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan (Korea, Republic of)

    2016-12-15

    Cyclometalated iridium (III) complexes formed with three identical cyclometalating (C-N) ligands (homoleptic) or formed with two cyclometalating (C-N) ligands and one ancillary (LX) ligand (heteroleptic) have been known as highly phosphorescent materials and, thus, they have been utilized as efficient phosphorescent dopants in organic light emitting diodes (OLEDs) 1–3 or as effective phosphorescent chemosensors. 4–7 Cylometalated iridium (III) complexes are chiral compounds consisting of lambda (Λ, left-handed) and delta (Δ, right-handed) isomers. Racemic cyclometa- lated iridium (III) complexes emit light with no net polarization, but optically active cyclometalated iridium (III) complexes emit circularly polarized light. 8,9 Circularly polarized light can be used in various fields including highly efficient three dimensional electronic devices, photo nic devices for optical data storage, biological assays, and others. 8,9 In order to obtain optically active cylometalated iridium (III) complexes and to determine the enantiomeric composition of optically active cylometalated iridium (III) complexes, liquid chromatogr aphic enantiomer separation method on chiral stationary phases (CSPs) has been used. For example, Okamoto and coworkers first reported the high performance liquid chromatographic (HPLC) direct enantiomeric separation of two homoleptic cylometalated iridium (III) complexes on immobilized amylose tris(3,5- dimethylphenylcarbamate) (Chiralpak IA), coated cellulose tris(3,5-dimethylphenylcarbamate) (Chiralc el OD), and coated cellulose tris(4-methylbenzoate) (Chiralce l OJ). 10 Supercritical fluid chromatography (SFC) was also used by Bernhard and coworkers for the enantiomeric separation of cylometalated iridium (III) complexes on coated amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD-H). 8 However, the general use of the HPLC method for the direct enantiomeric separation of homoleptic.

  17. Behavior of new complexes of tetrakis(4-methoxylphenyl)porphyrin with heavy rare earth elements in reversed-phase high performance liquid chromatography.

    Science.gov (United States)

    Zhang, Jun-Feng; Wang, Hong; Hou, An-Xin; Wang, Chang-Fa; Zhang, Hua-Shan

    2004-08-01

    An HPLC method has been developed for the separation of new complexes of tetrakis(4-methoxylphenyl)porphyrin (TMOPP) with four heavy rare earth elements (RE = Y, Er, Tm, and Yb). The function of amine and acid in the mobile phase has been investigated and a reasonable explanation is presented. Successful separation of the RE-TMOPP-Cl complexes is accomplished in 10 min with a mobile phase consisting of methanol-water-acetic acid-triethanolamine. The detection limits (S/N= 3) for the four complexes are 0.01 microg/mL. This method is rapid, sensitive, and simple.

  18. MODELS OF PROJECT REVERSE ENGINEERING

    Directory of Open Access Journals (Sweden)

    Віктор Володимирович ІВАНОВ

    2017-03-01

    Full Text Available Reverse engineering decided important scientific and technical problems of increasing the cost of the existing technical product by transforming it into a product with other features or design. Search ideas of the new application of existing products on the base of heuristic analysis were created. The concept of reverse engineering and its division into three types: conceptual, aggregate and complete was expanded. The use of heuristic methods for reverse engineering concept was showed. The modification model of Reverse engineering based on the model of РМВОК was developed. Our model includes two new phases: identification and transformation. At the identification phase, technical control is made. At the transformation phase, search heuristic idea of the new applied existing technical product was made. The model of execution phase that included heuristic methods, metrological equipment, and CAD/CAM/CAE program complex was created. The model that connected economic indicators of reverse engineering project was developed.

  19. Analysis of ribo- and deoxyribonucleic acids using ionpair-reversed-phase liquid-chromatography electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    Hoelzl, G.

    2002-10-01

    The fast progress in natural sciences like biology, biochemistry, medicine or genetics make high demands on the analytical chemistry. The on-line coupling of ionpair-reversed phase-liquid chromatography (IP-RP-HPLC) to mass spectrometry (MS) becomes more and more the method of choice for the analysis of biomolecules. The success is based on the introduction of soft ionization methods, like electrospray ionization (ESI), which allows the transfer of intact biopolymers into the gasphase. This combination enables the on-line separation of complex biological mixtures with additional identification of the compounds by their molecular mass. The first part describes the development of a new ionsource, which combines the advantages of a micro-ESI- and a nanospray-source. In combination with additional optimization of the chromatographic conditions the new ionsource showed an improvement of the quality of the spectra by a factor of 5 and a stability of the ionspray by a factor of 2, which resulted in an overall improvement of sensitivity by a factor of 10 for the HPLC-MS system. The second part describes the quality control of synthetic RNA molecules. Using IP-RP-HPLC-ESI-MS it was possible to separate failure sequences and derivatives in raw products of short synthetic RNAs. The derivatives were formed of protecting groups, which were not removed during the deprotection step. The analysis of coupling products of the synthesis of aminoacylated transfer RNAs showed a derivative, which was formed by the addition of the used coupling reagent N-(3-dimethylaminopropyl)N'-ethylcarbodiimide (EDC). The identification of the derivatives led to the optimization of the reaction conditions which resulted in the synthesis of the wanted transfer RNA without any additional derivatives. Another experiment involved the fragmentation of RNA molecules. Tandem mass spectrometry provides the opportunity to determine the sequence of nucleic acids. Fragmentation experiments showed different

  20. X-ray phase radiography and tomography with grating interferometry and the reverse projection technique

    International Nuclear Information System (INIS)

    Wang, Zhili; Gao, Kun; Ge, Xin; Wu, Zhao; Chen, Heng; Wang, Shenghao; Wu, Ziyu; Zhu, Peiping; Yuan, Qingxi; Huang, Wanxia; Zhang, Kai

    2013-01-01

    X-ray grating interferometry provides substantially increased contrast over conventional absorption-based imaging methods, and therefore new and complementary information. Compared with other phase-contrast imaging techniques, x-ray grating interferometry can overcome some of the problems that have impaired the applications of x-ray phase-contrast radiography and phase tomography. Recently, special attention has been paid to the development of quantitative phase retrieval methods, which is mandatory to perform x-ray phase tomography, to achieve material identification, to differentiate distinct tissues, etc. Typically, the phase-stepping approach has been utilized for phase retrieval in grating interferometry. This method requires a grating scanning and acquisition of multiple radiographic projections, and therefore is disadvantageous in terms of imaging speed and radiation damage. Here we present an innovative, highly sensitive approach, dubbed ‘reverse projection’ (RP), for quantitative phase retrieval. Compared with the phase-stepping approach, the present RP method abandons grating scanning completely, and thus is advantageous due to its much higher efficiency and the reduced radiation dose, without the degradation of reconstruction quality. This review presents a detailed explanation of the principle of the RP method. Both radiography and phase tomography experiments are performed to validate the RP method. We believe that this new technique will find widespread applications in biomedical imaging and in vivo studies. (paper)

  1. Determination of sulfonamides and trimethoprim using high temperature HPLC with simultaneous temperature and solvent gradient.

    Science.gov (United States)

    Giegold, Sascha; Teutenberg, Thorsten; Tuerk, Jochen; Kiffmeyer, Thekla; Wenclawiak, Bernd

    2008-10-01

    A fast HPLC method for the analysis of eight selected sulfonamides (SA) and trimethoprim has been developed with the use of high temperature HPLC. The separation could be achieved in less than 1.5 min on a 50 mm sub 2 microm column with simultaneous solvent and temperature gradient programming. Due to the lower viscosity of the mobile phase and the increased mass transfer at higher temperatures, the separation could be performed on a conventional HPLC system obtaining peak widths at half height between 0.6 and 1.3 s.

  2. Simultaneous quantitative determination of zidovudine and ...

    African Journals Online (AJOL)

    Methods: Standard stock solutions for HPLC analysis were prepared by ... In the HPLC measurement, sample detection was carried out at 246 nm using an ... Human plasma, Reverse phase high- performance liquid chromatography. Tropical ...

  3. Potency determination of follitropin, lutropin And thyrotropin: a comparison between the quantification by reversed-phase high-performance liquid chromatography and in vivo bioassay; Determinacao de potencia de diferentes preparacoes de foliculotrofina, luteotrofina e tireotrofina: comparacao entre a quantificacao por cromatografia liquida em fase reversa e por bioensaio in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Beatriz Elane de

    2013-07-01

    With the intention of setting up physico-chemical methods as an alternative to in vivo bioassay for determining biological activity, the hFSH, hTSH and hLH content of native and recombinant preparations was determined by reversed-phase high-performance liquid chromatography (RP-HPLC) and compared with the data obtained by the classical mouse or rat in vivo bioassays (BA). A linear relationship between the two methods was found for these hormones: hFSH BA{sub U=} 0.9925 RP-HPLC{sub U–} 1.3165, r = 0.9371, p < 0.001, n = 24; hTSH BAμg = 0.9790 RP-HPLCμg - 0.052, r = 0.8725, p < 0.001, n = 14; hLH BA{sub IU} = 0.8771 RP-HPLC{sub IU} + 12.41, r = 0.9786, p < 0.01, n = 5. For nine other hFSH and eleven hTSH preparations, the mean difference ( ) between the bioactivity predicted from RP-HPLC data via these equations and the mean of the bioactivities obtained with the two methods was as follows. For hLH this difference could not be estimated due to lack of different samples. In the case of hFSH, ± SD = -2.11 ± 3.49% with a precision of 1.16% and in the case of hTSH, ± SD = -2.01 ± 5.56 %, with precision of 1.68%. Partly-degraded hFSH, hTSH and hLH samples presented different activity degrees that could be predicted by RP-HPLC, with an acceptable agreement with the in vivo bioassays. These results demonstrate that the employment of a non-animal physico-chemical assay, such as RP-HPLC, is a viable alternative to the use of an in vivo bioassay for hFSH and hTSH potency determination, thus reducing the number of animals currently used for assuring quality and efficacy of a pharmaceutical product. (author)

  4. Simultaneous determination of naphthalene and anthraquinone derivatives in Rumex nepalensis Spreng. roots by HPLC: comparison of different extraction methods and validation.

    Science.gov (United States)

    Gautam, Raju; Srivastava, Amit; Jachak, Sanjay M

    2011-01-01

    Rumex nepalensis contains mainly anthraquinone and naphthalene derivatives. Although HPLC methods have been reported for the analysis of anthraquinones, neither a phytochemical analysis of Rumex species nor the simultaneous determination of anthraquinone and naphthalene derivatives in other samples has been reported so far. To develop and validate a HPLC method for the simultaneous determination of anthraquinone and naphthalene derivatives in R. nepalensis roots. Anthraquinones and naphthalenes were extracted from R. nepalensis roots by three methods (reflux, ultrasonication and pressurized liquid extraction) using methanol. Separation was achieved on an RP C₁₈ column with a gradient mobile phase consisting of 0.05% orthophosphoric acid in water (solvent A) and methanol (solvent B) using a UV detector (254 nm). Small differences were observed in the contents of anthraquinone and naphthalene derivatives extracted by the three methods. Chrysophanol-8-O-β-D-glucopyranoside and nepodin were detected as major constituents. The method showed a good linearity (r² > 0.9992), high precision (RSD anthraquinones and naphthalenes in R. nepalensis and other Rumex species for both quality control as well as routine analytical purposes. Copyright © 2010 John Wiley & Sons, Ltd.

  5. HPLC, NMR and MALDI-TOF MS Analysis of Condensed Tannins from Lithocarpus glaber Leaves with Potent Free Radical Scavenging Activity

    OpenAIRE

    Zhang, Liang Liang; Lin, Yi Ming

    2008-01-01

    Using acid-catalyzed degradation in the presence of cysteamine, the condensed tannins from Lithocarpus glaber leaves were characterized, following thiolysis, by means of reversed-phase HPLC, 13C-NMR and matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) analyses. The thiolysis reaction products showed the presence of the procyanidin (PC) and prodelphinidin (PD) structures. The 13C-NMR spectrum revealed that the condensed tannins were comprised of PD (7...

  6. Ionisation constants of radiopharmaceuticals by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Stylli, C.G.; Theobald, A.E.

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation.

  7. Ionisation constants of radiopharmaceuticals by HPLC

    International Nuclear Information System (INIS)

    Stylli, C.G.; Theobald, A.E.

    1986-01-01

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation. (author)

  8. A reversed-phase compatible thin-layer chromatography autography for the detection of acetylcholinesterase inhibitors.

    Science.gov (United States)

    Ramallo, I Ayelen; García, Paula; Furlan, Ricardo L E

    2015-11-01

    A dual readout autographic assay to detect acetylcholinesterase inhibitors present in complex matrices adsorbed on reversed-phase or normal-phase thin-layer chromatography plates is described. Enzyme gel entrapment with an amphiphilic copolymer was used for assay development. The effects of substrate and enzyme concentrations, pH, incubation time, and incubation temperature on the sensitivity and the detection limit of the assay were evaluated. Experimental design and response surface methodology were used to optimize conditions with a minimum number of experiments. The assay allowed the detection of 0.01% w/w of physostigmine in both a spiked Sonchus oleraceus L. extract chromatographed on normal phase and a spiked Pimenta racemosa (Mill.) J.W. Moore leaf essential oil chromatographed on reversed phase. Finally, the reversed-phase thin-layer chromatography assay was applied to reveal the presence of an inhibitor in the Cymbopogon citratus (DC.) Stapf essential oil. The developed assay is able to detect acetylcholinesterase inhibitors present in complex matrixes that were chromatographed in normal phase or reversed-phase thin-layer chromatography. The detection limit for physostigmine on both normal and reversed phase was of 1×10(-4) μg. The results can be read by a change in color and/or a change in fluorescence. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

    Science.gov (United States)

    Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G

    2001-10-01

    Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P manual, single-component analyses.

  10. Research on Linux Trusted Boot Method Based on Reverse Integrity Verification

    Directory of Open Access Journals (Sweden)

    Chenlin Huang

    2016-01-01

    Full Text Available Trusted computing aims to build a trusted computing environment for information systems with the help of secure hardware TPM, which has been proved to be an effective way against network security threats. However, the TPM chips are not yet widely deployed in most computing devices so far, thus limiting the applied scope of trusted computing technology. To solve the problem of lacking trusted hardware in existing computing platform, an alternative security hardware USBKey is introduced in this paper to simulate the basic functions of TPM and a new reverse USBKey-based integrity verification model is proposed to implement the reverse integrity verification of the operating system boot process, which can achieve the effect of trusted boot of the operating system in end systems without TPMs. A Linux operating system booting method based on reverse integrity verification is designed and implemented in this paper, with which the integrity of data and executable files in the operating system are verified and protected during the trusted boot process phase by phase. It implements the trusted boot of operation system without TPM and supports remote attestation of the platform. Enhanced by our method, the flexibility of the trusted computing technology is greatly improved and it is possible for trusted computing to be applied in large-scale computing environment.

  11. [Determination of triterpenoic acids in fruits of Ziziphus jujuba using HPLC-MS with polymeric ODS column].

    Science.gov (United States)

    Zhang, Yong; Zhou, An; Xie, Xiao-Mei

    2013-03-01

    A simple and sensitive method has been developed to simultaneously determine betunilic acid, oleanolic acid and ursolic acid in the fruits of Ziziphus jujuba from different regions by HPLC-MS. This HPLC assay was performed on PAH polymeric C18 bonded stationary phase column with mobile phase contained acetonitrile-water (90: 10) and with negative ESI detection mode. The developed approach was characterized by short time consumption for chromatographic separation, high sensitivity and good reliability so as to meet the requirements for rapid analysis of large-batch fruits of Z. jujuba from different habitats.

  12. New validated method for piracetam HPLC determination in human plasma.

    Science.gov (United States)

    Curticapean, Augustin; Imre, Silvia

    2007-01-10

    The new method for HPLC determination of piracetam in human plasma was developed and validated by a new approach. The simple determination by UV detection was performed on supernatant, obtained from plasma, after proteins precipitation with perchloric acid. The chromatographic separation of piracetam under a gradient elution was achieved at room temperature with a RP-18 LiChroSpher 100 column and aqueous mobile phase containing acetonitrile and methanol. The quantitative determination of piracetam was performed at 200 nm with a lower limit of quantification LLQ=2 microg/ml. For this limit, the calculated values of the coefficient of variation and difference between mean and the nominal concentration are CV%=9.7 and bias%=0.9 for the intra-day assay, and CV%=19.1 and bias%=-7.45 for the between-days assay. For precision, the range was CV%=1.8/11.6 in the intra-day and between-days assay, and for accuracy, the range was bias%=2.3/14.9 in the intra-day and between-days assay. In addition, the stability of piracetam in different conditions was verified. Piracetam proved to be stable in plasma during 4 weeks at -20 degrees C and for 36 h at 20 degrees C in the supernatant after protein precipitation. The new proposed method was used for a bioequivalence study of two medicines containing 800 mg piracetam.

  13. C18, C8, and perfluoro reversed phases on diamond for solid-phase extraction.

    Science.gov (United States)

    Saini, Gaurav; Wiest, Landon A; Herbert, David; Biggs, Katherine N; Dadson, Andrew; Vail, Michael A; Linford, Matthew R

    2009-04-17

    In spite of advances in solid-phase extraction (SPE) technology there are certain disadvantages to current SPE silica-based, column packings. The pH range over which extraction can occur is limited and each column is generally only used once. New diamond-based reversed SPE phases (C(18), C(8), and perfluorinated) were developed in our laboratories. Studies were done which show that these phases do not have the same limitations as traditional silica-based stationary phases. The synthesis and properties of these diamond-based phases are presented, and the stability, percent recovery, and column capacity are given for the C(18) phase.

  14. Stability indicating RP-HPLC method for simultaneous determination of piroxicam and ofloxacin in binary combination.

    Science.gov (United States)

    John, Peter; Azeem, Waqar; Ashfaq, Muhammad; Khan, Islam Ullah; Razzaq, Syed Naeem

    2015-09-01

    A simple and precise RP-HPLC method was developed for simultaneous determination of piroxicam and ofloxacin in pharmaceutical formulations and human serum. Optimum separations of piroxicam, ofloxacin and stress-induced degradation products were achieved by use of Hypersil BDS C8 column (250 x 4.6mm, 5 μm). The mobile phase was a mixture of acetonitrile: 0.012M K2HPO4: 0.008M sodium citrate (both buffers mixed and pH adjusted to 2.8) (50:25:25 v/v/v) delivered at flow rate of 1.5 mL min⁻¹ using DAD at 254 nm. Response was linear function of concentration over the ranges of 70-130 mg mL⁻¹ for piroxicam and ofloxacin (r² ≥ 0.999). The method efficiently separated the analytical peaks from degradation products with acceptable tailing and resolution. The developed method was successfully used for concurrent analysis of piroxicam and ofloxacin in pharmaceutical formulations, human serum and in vitro drug interaction studies.

  15. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    Science.gov (United States)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  16. Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods

    Directory of Open Access Journals (Sweden)

    Milovanović Vesna

    2012-01-01

    Full Text Available Background/Aim. Saliva represents an alternative specimen for substances abuse determination in toxicology. Hence, the aim of this study was to optimize a method for saliva specimen preparation for heroin metabolites, morphine and 6-monoacetylmorphine (6-mam, and codeine determination by liquid chromatography-mass spectrometry (LC/MS, and to apply this method on saliva samples taken from the patients. Methods. Saliva specimen was prepared using liqiud/liquid extraction of morphine, codeine and 6- mam by mixture of chloroform and isopropanol (9 : 1; v/v. Extracts were analysed by HPLC/MS technique: separation column Waters Spherisorb® 5 μm, ODS2, 4.6 × 100 mm; mobile phase: ammonium acetate : acetonitile (80 : 20; v/v, mobile phase flow rate 0.3 mL/min; mass detection range: 100-400 m/z. Regression and correlation analyses were performed with the probalility level of 0.05. Concentrations of morphine, codeine and 6-mam were determined in saliva samples of the patients with “opiates” in urine identified by the test strips. Results. Calibration for each analysed substance was done in the concentration range from 0.1 to 1 mg/L and the coefficient of correlation was R2 > 0.99. We obtained following calibration curves: y = 385531x + 14584; y = 398036x + 31542; and y = 524162x - 27105, for morphine, codeine and 6-mam, respectively. Recovery for morphine and codeine determination was 99%, while for 6- mam it was 94%. Limits of detection and quantification of a proposed method were 0.01 mg/L and 0.05 mg/L, respectively. Concentration of morphine in the saliva of the heroin users ranged between 0.54 and 5.82 mg/L, concentration of codeine between 0.05 and 5.33, and 6-mam between 0.01 and 0.68 mg/L. A statistically significant correlation between codeine and 6-mam concentrations was obtained. Conclusion. A proposed HPLC/MS method for morphine, codeine and 6-mam determination in saliva is accurate, simple, cheap and suitable for routine analysis and

  17. Analysis of phosphorus herbicides by ion-pairing reversed-phase liquid chromatography coupled to inductively coupled plasma mass spectrometry with octapole reaction cell.

    Science.gov (United States)

    Sadi, Baki B M; Vonderheide, Anne P; Caruso, Joseph A

    2004-09-24

    A reversed phase ion-pairing high performance liquid chromatographic (RPIP-HPLC) method is developed for the separation of two phosphorus herbicides, Glufosinate and Glyphosate as well as Aminomethylphosphonic acid (AMPA), the major metabolite of Glyphosate. Tetrabutylammonium hydroxide is used as the ion-pairing reagent in conjunction with an ammonium acetate/acetic acid buffering system at pH 4.7. An inductively coupled plasma mass spectrometer (ICP-MS) is coupled to the chromatographic system to detect the herbicides at m/z = 31P. Historically, phosphorus has been recognized as one of the elements difficult to analyze in argon plasma. This is due to its relatively high ionization potential (10.5 eV) as well as the inherent presence of the polyatomic interferences 14N16O1H+ and 15N16O+ overlapping its only isotope at m/z = 31. An octapole reaction cell is utilized to minimize the isobaric polyatomic interferences and to obtain the highest signal-to-background ratio. Detection limits were found to be in the low ppt range (25-32 ng/l). The developed method is successfully applied to the analysis of water samples collected from the Ohio River and spiked with a standard compounds at a level of 20 microg/l.

  18. Design of simple UV Spectrophotometric and HPLC methods for assay of artesunate and amodiaquine in fixed dose tablet formulations

    International Nuclear Information System (INIS)

    Ashie, Agatha Dei

    2013-07-01

    Artesunate and Amodiaquine combination is one of the first line drugs for the treatment of uncomplicated malaria. To prevent treatment failures and emergence of resistant strains of the Plasmodium parasite, patients are entreated to comply with treatment regimens. Thus fixed dose tablet formulations came as a relieve to patients, ensuring proper compliance as the number of tablets to be taken was reduced. It is therefore important to develop simple methods of assay for these formulations to ensure that quality drugs are available and to prevent resistance to these drugs. This thesis describes Ultraviolet (UV) and High Performance Liquid Chromatographic (HPLC) methods of assay for Artesunate (AS) and Amodiaduine Hydrochloride (AMQ) in fixed dose tablet formulations. The UV absorption spectroscopy was used to establish a wavelength of maximum absorption and the Beer’s plot generated. At 339nm, Amodiaquine Hydrochloride was assayed accurately in methanol with a high r"2 value of 0.998, an intra and inter day precision of Relative Standard Deviation (RSD) of 1.52% and 1.86% respectively. The Beer’s plot was obeyed in a concentration range of 3.5 - 24.8(µg/mL). The limit of detection and limit of quantification was 1.23(µg/mL) and 3.73(µg/mL) respectively. However the UV method could not be used to assay AS simultaneously with AMQ. A mobile phase of 60% acetonitrile and 40% of 0.05% trifluoroacetic acid, flow rate of 1ml/min, wavelength of detection of 225nm and a C_1_8 stationary phase are the parameters for the HPLC method. The r"2 for the HPLC method was 0.996 and 0.995 for Amodiaquine hydrochloride and Artesunate respectively. The intra and inter day precision were 1.07% and 1.42% respectively. The limit of detection and limit of quantification were 0.015%w/v and 0.0465%w/v for Amodiaquine hydrochloride and 0.054%w/v and 0.019%w/v for Artesunate respectively. The concentration ranges were 0.01 - 0.16%w/v for Amodiaquine hydrochloride and 0.01 – 0.2%w/v for

  19. Determination of n-octanol/water partition coefficient for DDT-related compounds by RP-HPLC with a novel dual-point retention time correction.

    Science.gov (United States)

    Han, Shu-ying; Qiao, Jun-qin; Zhang, Yun-yang; Yang, Li-li; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan

    2011-03-01

    n-Octanol/water partition coefficients (P) for DDTs and dicofol were determined by reversed-phase high performance liquid chromatography (RP-HPLC) on a C(18) column using methanol-water mixture as mobile phase. A dual-point retention time correction (DP-RTC) was proposed to rectify chromatographic retention time (t(R)) shift resulted from stationary phase aging. Based on this correction, the relationship between logP and logk(w), the logarithm of the retention factor extrapolated to pure water, was investigated for a set of 12 benzene homologues and DDT-related compounds with reliable experimental P as model compounds. A linear regression logP=(1.10±0.04) logk(w) - (0.60±0.17) was established with correlation coefficient R(2) of 0.988, cross-validated correlation coefficient R(cv)(2) of 0.983 and standard deviation (SD) of 0.156. This model was further validated using four verification compounds, naphthalene, biphenyl, 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (p,p'-DDD) and 2,2-bis(4-chlorophenyl)-1,1-dichloroethene (p,p'-DDE) with similar structure to DDT. The RP-HPLC-determined P values showed good consistency with shake-flask (SFM) or slow-stirring (SSM) results, especially for highly hydrophobic compounds with logP in the range of 4-7. Then, the P values for five DDT-related compounds, 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1,1-trichloroethane (o,p'-DDT), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethane (o,p'-DDD), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene (o,p'-DDE), and 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its main degradation product 4,4'-dichlorobenzophenone (p,p'-DBP) were evaluated by the improved RP-HPLC method for the first time. The excellent precision with SD less than 0.03 proved that the novel DP-RTC protocol can significantly increases the determination accuracy and reliability of P by RP-HPLC. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Determination of antibiotics such as macrolides, ionophores and tiamulin in liquid manure by HPLC-MS/MS.

    Science.gov (United States)

    Schlüsener, Michael P; Bester, Kai; Spiteller, Michael

    2003-04-01

    A method for the analysis of several macrolide and ionophore antibiotics as well as tiamulin in liquid manure was developed. Reversed-phase liquid chromatography and atmospheric pressure chemical ionisation (APCI) tandem mass spectrometry was used for detection.High-performance liquid chromatographic (HPLC) separation of the antibiotics was achieved in 35 min. The analytes were extracted with ethyl acetate and the extracts were cleaned up by solid-phase extraction on a diol SPE cartridge. Recovery experiments with spiked liquid manure concentrations varying from 6 to 2,000 microg kg(-1) gave constant recovery rates. The recovery rates for the macrolides erythromycin, roxithromycin and oleandomycin were 75-94%, that for the ionophore salinomycin was 119%, while that for the pleuromutilin tiamulin was 123%, when using a macrolide internal standard. The relative standard deviation was found to be 15-36% and the limits of detection were 0.4-11.0 micro g kg(-1). The maximum concentrations found in manure samples were 43 micro g kg(-1) for tiamulin and 11 micro g kg(-1) for salinomycin.

  1. Quantitation of fumonisin B1 and B2 in feed using FMOC pre-column derivatization with HPLC and fluorescence detection.

    Science.gov (United States)

    Smith, Lori L; Francis, Kyle A; Johnson, Joseph T; Gaskill, Cynthia L

    2017-11-01

    Pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was determined to be effective for quantitation of fumonisins B 1 and B 2 in feed. Liquid-solid extraction, clean-up using immunoaffinity solid phase extraction chromatography, and FMOC-derivatization preceded analysis by reverse phase HPLC with fluorescence. Instrument response was unchanged in the presence of matrix, indicating no need to use matrix-matched calibrants. Furthermore, high method recoveries indicated calibrants do not need to undergo clean-up to account for analyte loss. Established method features include linear instrument response from 0.04-2.5µg/mL and stable derivatized calibrants over 7days. Fortified cornmeal method recoveries from 0.1-30.0μg/g were determined for FB 1 (75.1%-109%) and FB 2 (96.0%-115.2%). Inter-assay precision ranged from 1.0%-16.7%. Method accuracy was further confirmed using certified reference material. Inter-laboratory comparison with naturally-contaminated field corn demonstrated equivalent results with conventional derivatization. These results indicate FMOC derivatization is a suitable alternative for fumonisins B 1 and B 2 quantitation in corn-based feeds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Stability-Indicating RP-HPLC Method for Analysis of Paracetamol and Tramadol in a Pharmaceutical Dosage Form

    OpenAIRE

    Kamble, Rajesh M.; Singh, Shrawan G.

    2012-01-01

    A simple, isocratic, rapid and accurate reversed phase high performance liquid chromatography method was developed for the quantitative determination of paracetamol and tramadol in commercial medicinal tablets. The chromatographic separation was achieved on an Intersil C18 (250 mm x 4.6 mm, 5μm) column using water pH 3.4 with orthophosphoric acid: methanol (60:40, v/v) as a mobile phase, and UV detection at 228 nm. The chromatographic resolutions between paracetamol and tramadol were found gr...

  3. 檀香叶中的γ-氨基丁酸的HPLC测定研究%Determination of γ-Aminobutyric Acid in Leaves of Santalum album L.by HPLC

    Institute of Scientific and Technical Information of China (English)

    杨艳; 贺丽苹; 高向阳

    2013-01-01

    A method was established by reversed-phase high performance liquid chromatography for determining the content of y-aminobutyric acid ( GABA) in leaves of Santalum album L. The sample was pretreated by soxhlet extraction to eliminate the pigments with ether, and then by water extraction and alcohol precipitation to eliminate sugar and protein. GABA was derivatized with dansyl chloride (Dns-Cl) and isolated by reversed-phase HPLC. GABA was detected quantitatively by HPLC with fluorescence detection. Nice linear relationship between peak area and concentration was obtained with the linear regression equation as y=475 211x+69 037,R2 =0.999 8. The recovery of standard addition was in the range of 112% to 120%. The detection limit of GABA was 7 μg/g. The established HPLC method is simple, economic, stable and accurate with good reproducibility. It can be applied on determination of GABA in leaves of Santalum album L.%建立了檀香叶中γ-氨基丁酸(GABA)含量的高效液相色谱检测方法.以乙醚为溶剂,采用索氏提取除去色素,水提醇沉去除糖类和蛋白质的净化方法,以丹酰氯为衍生剂,高效液相色谱法分离,荧光检测器测定,外标法定量.峰面积与浓度之间线性关系良好,回归方程为y=475 211x+ 69 037,R2=0.999 8,加标回收率为112 %~120%,检测限为7μg/g.该方法操作步骤简单,灵敏度高,用于檀香叶中GABA的检测,方法简便、准确、高效.

  4. Validation of HPLC method for the simultaneous and quantitative determination of 12 UV-filters in cosmetics.

    Science.gov (United States)

    Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O

    2010-02-01

    The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.

  5. A Simple and Sensitive HPLC Method for Simultaneous Analysis of Nabumetone and Paracetamol in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Prafulla Kumar Sahu

    2011-01-01

    Full Text Available This paper describes a high-performance liquid chromatographic method for simultaneous estimation of nabumetone and paracetamol in binary mixture. The method was based on RP-HPLC separation and quantitation of the two drugs on hypersil C-18 column (250 mm × 4.6 mm using a mobile phase consisting of acetonitrile and 0.05% aqueous acetic acid (70:30v/v at flow rate of 1 mL min-1. Quantitation was achieved with PDA detector at 238 nm based on peak area with linear calibration curves at concentration ranges 5-25 µg mL-1 for both the drugs. Naproxen sodium was used as internal standard. The method has been successively applied to pharmaceutical formulation. No chromatographic interference from the tablet excipients was found. The method was validated in terms of precision, robustness, recovery and limits of detection and quantitation. The intra and inter-day precision and accuracy values were in the acceptance range as per ICH guidelines.

  6. Development of a simple, rapid and reproducible HPLC assay for the simultaneous determination of hypericins and stabilized hyperforin in commercial St. John's wort preparations.

    Science.gov (United States)

    de los Reyes, G C; Koda, R T

    2001-12-01

    A reversed-phase HPLC method was developed and validated for the simultaneous determination of hypericins and stabilized hyperforin in St. John's wort extract. The sample solution was prepared by extraction of the finely powdered extract with methanol-water (80:20, v/v) containing 5% HP-beta-cyclodextrin, and adjusted to pH 2.5 with orthophosphoric acid. Diluted extract solutions, maintained at 0 degrees C, were injected into a C18 column. The samples were eluted isocratically using a mobile phase consisting of acetonitrile and 0.3% v/v phosphoric acid (90:10, v/v) at a 1.5 ml/min flow rate with simultaneous fluorescence (315/590 nm, excitation/emission) and UV (273 nm) detection. Quantification of the marker compounds (hypericin, pseudohypericin, hyperforin) was achieved by use of standard curves generated by plotting peak heights versus concentrations. Validation studies demonstrated that this HPLC method is simple, rapid, reliable, and reproducible. The standard curves were linear over the concentration ranges, 0.5-2.5 microg/ml (hypericin), 0.35-1.6 microg/ml (pseudohypericin) and 5-50 microg/ml (hyperforin). The intra-day coefficients of variation obtained for hypericin, pseudohypericin and hyperforin were < or = 4.4%, < or = 5.4%, and < or = 2.8%, respectively; inter-day CVs were < or = 5.8%, < or = 4.9%, and < or = 2.5%, respectively. This method may be applied for the routine standardization of St. John's wort products against hyperforin and the hypericins, the putative antidepressant principles in the herbal.

  7. Analytical method development and Validation of Aml odipine Besylate and Nebivolol in their Dosage Form

    OpenAIRE

    Patel Jignesh; Patel Mandev

    2014-01-01

    This work is concerned with application of simple, economical, precise, accurate and reproducible reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of Nebivolol hydrochloride(NBH) and S-Amlodipine besylate (AMB) on thermo Hypersil C18 (Thermo Electron Corporation) (250 x 4.6 mm, 5 μm) using Acetonitrile and Phosphate buffer (pH 2.5 ± 0.1) in ratio of 60:40 as mobile phase. pH of buffer adjusted to 2.5 ± 0.1 with O-phosphoric acid. The flow rate...

  8. Forensic intoxication with clobazam: HPLC/DAD/MSD analysis.

    Science.gov (United States)

    Proença, Paula; Teixeira, Helena; Pinheiro, João; Marques, Estela P; Vieira, Duarte Nuno

    2004-07-16

    Clobazam (Castillium, Urbanil), a benzodiazepine often used as an anxiolytic and in the treatment of epilepsy, is considered a relatively safe drug. The authors present a fatal case with a 49-year-old female, found dead at home. She had been undergoing psychiatric treatment and was a chronic alcoholic. The autopsy findings were unremarkable, except for multivisceral congestion, steatosis and a small piece of a plastic blister pack in the stomach. Bronchopneumonia, bronchitis and bronchiolitis were also diagnosed. Anhigh-performance liquid chromatography (HPLC)/diode array detector (DAD)/mass spectrometry detection (MSD) with electrospray method was developed in order to detect, confirm and quantify clobazam in the post-mortem samples. In the chromatographic separation, a reversed-phase column C18 (2.1 x 150 mm, 3.5 microm) was used with a mobile phase of methanol and water, at a 0.25 ml/min flow rate. Carbonate buffer (pH 10.5) and 20 microl of prazepam (100 microg/ml) as internal standard were added to the samples. A simple and reliable liquid-liquid extraction method for the determination of clobazam in post-mortem samples was described. Calibration curves for clobazam were performed in blood, achieving linearity between 0.01 and 10 microg/ml and a detection limit of 1.0 ng/ml. The clobazam concentration found in post-mortem blood was 3.9 microg/ml, higher than the reported therapeutic concentration (0.1-0.4 microg/ml). The simultaneous acquisition by photodiode array detection and mass spectrometry detection results allowed benzodiazepines to be identified with sufficient certainty. An examination of all the available information suggested that death resulted from respiratory depression due to clobazam toxicity.

  9. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    Science.gov (United States)

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  10. [Determination of content and entrapment efficiency of 20 (S)-protopanaxadiol in pharmacosomes by RP-HPLC method].

    Science.gov (United States)

    Han, Meihua; Chen, Jing; Chen, Shilin; Wang, Xiangtao

    2009-05-01

    To establish a RP-HPLC method for content and entrapment efficiency of 20 (S)-protopanaxadiol in pharmacosomes. The separation was performed with a COSMOSIL 5 C18-MS-II column (4.6 mm x 250 mm, 5 mmicrom) using methanol-water (95:5) as the mobile phase and detected at 203 nm. The flow rate was 1.0 mL x min(-1) and 50 microL sample solution was injected for each time. The calibration curve was linear within the range 0.1-0.5 mg x mL(-1) (r = 0. 9999) , the intra-day RSD and inter-day RSD were less than 2% and the average recovery was between 101.44%-103.11% (n = 3). The method is simple, accurate, sensitive and applicable for determination of content and entrapment efficiency of 20 (S)-protopanaxadiol pharmacosomes.

  11. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids.

    Science.gov (United States)

    Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing

    2008-07-11

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method developed was successfully applied for primary screening of RTILs (>20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media.

  12. Attractive interactions between reverse aggregates and phase separation in concentrated malonamide extractant solutions

    International Nuclear Information System (INIS)

    Erlinger, C.; Belloni, L.; Zemb, T.; Madic, C.

    1999-01-01

    Using small angle X-ray scattering, conductivity, and phase behavior determination, the authors show that concentrated solutions of malonamide extractants, dimethyldibutyltetradecylmalonamide (DMDBTDMA), are organized in reverse oligomeric aggregates which have many features in common with reverse micelles. The aggregation numbers of these reverse globular aggregates as well as their interaction potential are determined from absolute scattering curves. An attractive interaction is responsible for the demixing of the oil phase when in equilibrium with excess oil. Prediction of conductivity as well as the formation conditions for the third phase is possible using standard liquid theory applied to the extractant aggregates. The interactions, modeled with the sticky sphere model proposed by Baster, are shown to be due to steric interactions resulting from the hydrophobic tails of the extractant molecule and van der Waals forces between the highly polarizable water core of the reverse micelles. The attractive interaction in the oil phase, equilibrated with water, is determined as a function of temperature, extractant molecule concentration, and proton and neodynium(III) cation concentration. It is shown that van der Waals interactions, with an effective Hamaker constant of 3kT, quantitatively explain the behavior of DMDBTDMA in n-dodecane in terms of scattering as well as phase stability limits

  13. Resveratrol-Loaded Polymeric Nanoparticles: Validation of an HPLC-PDA Method to Determine the Drug Entrapment and Evaluation of Its Antioxidant Activity

    OpenAIRE

    da Rocha Lindner, Gabriela; Khalil, Najeh Maissar; Mainardes, Rubiana Mara

    2013-01-01

    Poly(lactic acid) (PLA) and PLA-poly(ethylene glycol) (PLA-PEG) nanoparticles containing resveratrol (RVT) were developed, and their antioxidant activity was evaluated. An analytical method using high performance liquid chromatography (HPLC)/photodiode array (PDA) detection was also developed and validated for RVT determination in nanoparticles. The mobile phase consisted of methanol : water (51 : 49, v/v) flowed at 0.9 mL/min, and the PDA detector was set at wavelength of 306 nm. The mean di...

  14. New rapid methods for determination of total LAS in sewage sludge by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE)

    International Nuclear Information System (INIS)

    Villar, M.; Callejon, M.; Jimenez, J.C.; Alonso, E.; Guiraum, A.

    2009-01-01

    Linear alkylbenzene sulfonates (LAS) are the most common synthetic anionic surfactant used in domestic and industrial detergents, with a global production of 2.4 x 10 6 t year -1 . After use and disposal, LAS may enter the environment by one of the several routes, including by direct discharge to surface water or discharge to water from sewage treatment plants. Sewage treatment plants break down LAS only partly: some of them remain in effluent and other fraction is adsorbed in sewage solid. New and rapid methods for determination of total LAS from sewage sludge based on microwave assisted extraction and HPLC-FL and CE-DAD determination are proposed. The extraction of total LAS is carried out by using microwaves energy, an extraction time of 10 min and 5 mL of methanol. For HPLC-FL determination, mobile phase acetonitrile-water was used, comprising 60% (v/v) from 0 to 1 min and a flow rate of 1 mL min -1 programmed to 100% acetonitrile between 1 and 2 min and a flow rate of 2 mL min -1 . The final composition was maintained for a further 5 min. The determination of total LAS by CE-DAD was performed in a phosphate buffer (10 mM, pH 9). The separation voltage was 25 kV and the temperature of the capillary was 30 deg. C. Injections were performed in the pressure mode and the injection time was set at 12 s. The determination of total LAS is carried out in less than 5 min. The methods did not require clean-up or preconcentration steps. Detection limit for total LAS in the sludge was 3.03 mg kg -1 using HPLC-FL and 21.0 mg kg -1 using CE-DAD, and recoveries were >85% using both determination methods. Concentrations of total LAS obtained using both methods were compared with the sum of concentrations of homologues LAS C-10, LAS C-11, LAS C-12 and LAS C-13 obtained using microwaves assisted extraction and HPLC-FL and CE-DAD determination

  15. New rapid methods for determination of total LAS in sewage sludge by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE).

    Science.gov (United States)

    Villar, M; Callejón, M; Jiménez, J C; Alonso, E; Guiraúm, A

    2009-02-23

    Linear alkylbenzene sulfonates (LAS) are the most common synthetic anionic surfactant used in domestic and industrial detergents, with a global production of 2.4x10(6) t year(-1). After use and disposal, LAS may enter the environment by one of the several routes, including by direct discharge to surface water or discharge to water from sewage treatment plants. Sewage treatment plants break down LAS only partly: some of them remain in effluent and other fraction is adsorbed in sewage solid. New and rapid methods for determination of total LAS from sewage sludge based on microwave assisted extraction and HPLC-FL and CE-DAD determination are proposed. The extraction of total LAS is carried out by using microwaves energy, an extraction time of 10 min and 5 mL of methanol. For HPLC-FL determination, mobile phase acetonitrile-water was used, comprising 60% (v/v) from 0 to 1 min and a flow rate of 1 mL min(-1) programmed to 100% acetonitrile between 1 and 2 min and a flow rate of 2 mL min(-1). The final composition was maintained for a further 5 min. The determination of total LAS by CE-DAD was performed in a phosphate buffer (10 mM, pH 9). The separation voltage was 25 kV and the temperature of the capillary was 30 degrees C. Injections were performed in the pressure mode and the injection time was set at 12 s. The determination of total LAS is carried out in less than 5 min. The methods did not require clean-up or preconcentration steps. Detection limit for total LAS in the sludge was 3.03 mg kg(-1) using HPLC-FL and 21.0 mg kg(-1) using CE-DAD, and recoveries were >85% using both determination methods. Concentrations of total LAS obtained using both methods were compared with the sum of concentrations of homologues LAS C-10, LAS C-11, LAS C-12 and LAS C-13 obtained using microwaves assisted extraction and HPLC-FL and CE-DAD determination.

  16. Assessment of radiochemical purity of [{sup 18}F]fludeoxyglucose by high pressure liquid chromatography (HPLC)

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Aline E.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z., E-mail: radiofarmacoscdtn@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    The quality control of [{sup 18}F]fludeoxyglucose ({sup 18}FDG) has received attention due to its increasing clinical use. Although the quality requirements of {sup 18}FDG are established in various pharmacopoeia, the suitability of all testing methods used should be verified under actual conditions of use and documented. The aim of this study was to develop a high pressure liquid chromatography (HPLC) method for radiochemical purity evaluation of {sup 18}FDG, based on pharmacopoeia references, and to verify its suitability for routine quality control in our centre. HPLC analysis was performed with an Agilent HPLC. {sup 18}FDG and impurities were separated on an anion-exchange column by isocratic elution with 0.1 M NaOH as the mobile phase. Detection was accomplished with refractive index and NaI (Tl) scintillation detectors. The flow rate of the mobile phase was set at 0.8 mL/min and the column temperature was kept at 35 deg C. Specificity, linearity, precision and robustness were assessed to verify if the method was adequate for its intended purpose. Retention time of {sup 18}FDG was not affected by the presence of other components of the formulation and a good peak resolution was achieved. The analytical curve of {sup 18}FDG was linear, with a correlation coefficient value of 0.9995. Intraday repeatable precision, reported as the relative standard deviation, was 0.11%. Analytical procedure remained unaffected by small variations in mobile phase flow rate. Results evidenced that HPLC is suitable for radiochemical purity evaluation of {sup 18}FDG, considering operational conditions of our laboratory. (author)

  17. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area Método RP- HPLC validado para la determinación de residuos de Irinotecan Hidrocloruro para la validación de la limpieza en el área de producción

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  18. A thin film degradation study of a fluorinated polyether liquid lubricant using an HPLC method

    Science.gov (United States)

    Morales, W.

    1986-01-01

    A High Pressure Liquid Chromatography (HPLC) separation method was developed to study and analyze a fluorinated polyether fluid which is promising liquid lubricant for future applications. This HPLC separation method was used in a preliminary study investigating the catalytic effect of various metal, metal alloy, and ceramic engineering materials on the degradation of this fluid in a dry air atmosphere at 345 C. Using a 440 C stainless steel as a reference catalytic material it was found that a titanium alloy and a chromium plated material degraded the fluorinated polyether fluid substantially more than the reference material.

  19. An optimized high-performance liquid chromatography (HPLC method for benzoylmesaconine determination in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots and its products

    Directory of Open Access Journals (Sweden)

    Xu Hongxi

    2008-05-01

    Full Text Available Abstract Background Benzoylmesaconine (BMA is the main Aconitum alkaloid in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots with potent pharmacological activities, such as analgesia and anti-inflammation. The present study developed a simple and reliable method using BMA as a marker compound for the quality control of processed aconite roots and their products. Methods After extraction, a high-performance liquid chromatography (HPLC determination of BMA was conducted on a RP-C18 column by gradient elution with acetonitrile and aqueous phase, containing 0.1% phosphoric acid adjusted with triethylamine to pH 3.0. Results A distinct peak profile was obtained and separation of BMA was achieved. Method validation showed that the relative standard deviations (RSDs of the precision of BMA in all intra-day and inter-day assays were less than 1.36%, and that the average recovery rate was 96.95%. Quantitative analysis of BMA showed that the content of BMA varied significantly in processed aconite roots and their products. Conclusion This HPLC method using BMA as a marker compound is applicable to the quality control of processed aconite roots and their products.

  20. Simultaneous determination of hyoscine N-butyl bromide and paracetamol in their binary mixture by RP-HPLC method

    Directory of Open Access Journals (Sweden)

    Nouruddin W. Ali

    2017-05-01

    Full Text Available RP-HPLC chromatographic method was developed for the determination of hyoscine N-butyl bromide (HBB and Paracetamol (PAR. In this chromatographic method, HBB and PAR were separated using C18 (25 cm × 4.6 mm i.d. 5 μm particle size column as a stationary phase and water: methanol (50:50, V/V pH adjusted to 3.9 with CF3COOH acid as a mobile phase, maintaining the flow rate at 1.0 mL min−1 with UV detection at 210 nm. The proposed method was successfully applied for the determination of HBB and PAR in pure form over a concentration range of 2.0–50.0 μg mL−1 for HBB with mean percentage recovery of 100.10 ± 0.475 and over a concentration range of 5.0–200.0 μg mL−1 for PAR with mean percentage recovery of 99.87 ± 0.942 and in their pharmaceutical formulations (Buscopan plus® tablets, Buscamol® tablets and Buscopan plus® suppositories.