  1. Reverse osmosis water purification system

    Science.gov (United States)

    Ahlstrom, H. G.; Hames, P. S.; Menninger, F. J.

    1986-01-01

    A reverse osmosis water purification system, which uses a programmable controller (PC) as the control system, was designed and built to maintain the cleanliness and level of water for various systems of a 64-m antenna. The installation operates with other equipment of the antenna at the Goldstone Deep Space Communication Complex. The reverse osmosis system was designed to be fully automatic; with the PC, many complex sequential and timed logic networks were easily implemented and are modified. The PC monitors water levels, pressures, flows, control panel requests, and set points on analog meters; with this information various processes are initiated, monitored, modified, halted, or eliminated as required by the equipment being supplied pure water.

  2. Reverse Osmosis

    Indian Academy of Sciences (India)

    and is an Associate Faculty at Center for Sustainable. Technologies, Indian. Institute of Science,. Bangalore. His research areas include, unsaturated soil behaviour, hazardous waste management, water quality and remediation of contaminated water. Keywords. Osmosis, reverse osmosis, desalinatiion, seawater, water.

  3. Reverse Osmosis

    Indian Academy of Sciences (India)

    ment of Civil Engineering and is presently the. Chairman of Center for. Sustainable Technologies,. Indian Institute of Science,. Bangalore. His research areas include, unsaturated soil behaviour, hazardous waste management, water quality and remediation of contaminated water. Keywords. Osmosis, reverse osmosis,.

  4. Reverse Osmosis

    Indian Academy of Sciences (India)

    /fulltext/reso/012/05/0037-0040. Keywords. Osmosis; reverse osmosis; desalinatiion; seawater; water purification. Author Affiliations. Sudhakar M Rao1. Department of Civil Engineering, Indian Institute of Science, Bangalore 560012, India.

  5. Rotating Reverse-Osmosis for Water Purification

    Science.gov (United States)

    Lueptow, RIchard M.

    2004-01-01

    A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.

  6. Reverse osmosis desalination: water sources, technology, and today's challenges.

    Science.gov (United States)

    Greenlee, Lauren F; Lawler, Desmond F; Freeman, Benny D; Marrot, Benoit; Moulin, Philippe

    2009-05-01

    Reverse osmosis membrane technology has developed over the past 40 years to a 44% share in world desalting production capacity, and an 80% share in the total number of desalination plants installed worldwide. The use of membrane desalination has increased as materials have improved and costs have decreased. Today, reverse osmosis membranes are the leading technology for new desalination installations, and they are applied to a variety of salt water resources using tailored pretreatment and membrane system design. Two distinct branches of reverse osmosis desalination have emerged: seawater reverse osmosis and brackish water reverse osmosis. Differences between the two water sources, including foulants, salinity, waste brine (concentrate) disposal options, and plant location, have created significant differences in process development, implementation, and key technical problems. Pretreatment options are similar for both types of reverse osmosis and depend on the specific components of the water source. Both brackish water and seawater reverse osmosis (RO) will continue to be used worldwide; new technology in energy recovery and renewable energy, as well as innovative plant design, will allow greater use of desalination for inland and rural communities, while providing more affordable water for large coastal cities. A wide variety of research and general information on RO desalination is available; however, a direct comparison of seawater and brackish water RO systems is necessary to highlight similarities and differences in process development. This article brings to light key parameters of an RO process and process modifications due to feed water characteristics.

  7. Arsenic removal in drinking water by reverse osmosis

    OpenAIRE

    Ahmad, Md. Fayej

    2012-01-01

    Arsenic is widely distributed in nature in the air, water and soil. Acute and chronic arsenic exposure by drinking water has been reported in many countries, especially Argentina, Bangladesh, India, Mexico, Mongolia, Thailand and Taiwan. There are many techniques used to remove arsenic from drinking water. Among them reverse osmosis is widely used. Therefore the purpose of this study is to find the conditions favorable for removal of arsenic from drinking water by using reverse osmosis ...

  8. Microbial fouling of a reverse osmosis municipal water treatment system.

    Science.gov (United States)

    Wright, Steven J; Semrau, Jeremy D; Keeney, David R

    2008-08-01

    Microbial fouling of a municipal water treatment system using reverse osmosis was investigated. From a combination of growth and molecular assays, it was discovered that the prefilter unit concentrated and facilitated microbial growth, and such growth led to microbial fouling of the reverse osmosis unit. Few cells were observed in the prefilter influent, but substantial microbial contamination was observed in the prefilter effluent, and this correlated with increasing headloss across the prefilter. The effluent caused microbial fouling of the leading elements of the reverse osmosis unit, as determined by reduced permeate flow, analysis of the elements, and assays of the membrane foulant. Both the introduction of microorganisms to the reverse osmosis unit from the prefilter unit and headloss across the prefilter could be effectively controlled through cleansing of the prefilter housing unit with sulfuric acid. Such treatments must be performed at appropriate intervals to prevent subsequent microbial growth in the prefilter unit.

  9. Improvement of water desalination technologies in reverse osmosis plants

    Science.gov (United States)

    Vysotskii, S. P.; Konoval'chik, M. V.; Gul'ko, S. E.

    2017-07-01

    The strengthening of requirements for the protection of surface-water sources and increases in the cost of reagents lead to the necessity of using membrane (especially, reverse osmosis) technologies of water desalination as an alternative to ion-exchange technologies. The peculiarities of using reverse osmosis technologies in the desalination of waters with an increased salinity have been discussed. An analogy has been made between the dependence of the adsorptive capacity of ion-exchange resins on the reagent consumption during ion exchange and the dependence of the specific ion flux on the voltage in the electrodialysis and productivity of membrane elements on the excess of the pressure of source water over the osmotic pressure in reverse osmosis. It has been proposed to regulate the number of water desalination steps in reverse osmosis plants, which makes it possible to flexibly change the productivity of equipment and the level of desalinization, depending on the requirements for the technological process. It is shown that the selectivity of reverse osmotic membranes with respect to bivalent ions (calcium, magnesium, and sulfates) is approximately four times higher than the selectivity with respect to monovalent ions (sodium and chlorine). The process of desalination in reverse osmosis plants depends on operation factors, such as the salt content and ion composition of source water, the salt content of the concentrate, and the temperatures of solution and operating pressure, and the design features of devices, such as the length of the motion of the desalination water flux, the distance between membranes, and types of membranes and turbulators (spacers). To assess the influence of separate parameters on the process of reverse osmosis desalination of water solutions, we derived criteria equations by compiling problem solution matrices on the basis of the dimensional method, taking into account the Huntley complement. The operation of membrane elements was

  10. Reverse osmosis membrane of high urea rejection properties. [water purification

    Science.gov (United States)

    Johnson, C. C.; Wydeven, T. J. (Inventor)

    1980-01-01

    Polymeric membranes suitable for use in reverse osmosis water purification because of their high urea and salt rejection properties are prepared by generating a plasma of an unsaturated hydrocarbon monomer and nitrogen gas from an electrical source. A polymeric membrane is formed by depositing a polymer of the unsaturated monomer from the plasma onto a substrate, so that nitrogen from the nitrogen gas is incorporated within the polymer in a chemically combined form.

  11. Advanced Control Synthesis for Reverse Osmosis Water Desalination Processes.

    Science.gov (United States)

    Phuc, Bui Duc Hong; You, Sam-Sang; Choi, Hyeung-Six; Jeong, Seok-Kwon

    2017-11-01

      In this study, robust control synthesis has been applied to a reverse osmosis desalination plant whose product water flow and salinity are chosen as two controlled variables. The reverse osmosis process has been selected to study since it typically uses less energy than thermal distillation. The aim of the robust design is to overcome the limitation of classical controllers in dealing with large parametric uncertainties, external disturbances, sensor noises, and unmodeled process dynamics. The analyzed desalination process is modeled as a multi-input multi-output (MIMO) system with varying parameters. The control system is decoupled using a feed forward decoupling method to reduce the interactions between control channels. Both nominal and perturbed reverse osmosis systems have been analyzed using structured singular values for their stabilities and performances. Simulation results show that the system responses meet all the control requirements against various uncertainties. Finally the reduced order controller provides excellent robust performance, with achieving decoupling, disturbance attenuation, and noise rejection. It can help to reduce the membrane cleanings, increase the robustness against uncertainties, and lower the energy consumption for process monitoring.

  12. Fate of Thallium(I) in Reverse Osmosis and Chlorinated Water Matrices

    Science.gov (United States)

    2014-02-01

    THALLIUM(I) IN REVERSE OSMOSIS AND CHLORINATED WATER MATRICES ECBC-TR-1127 Approved for public release; distribution is unlimited...3. DATES COVERED (From - To) Apr 2010 - Dec 2011 4. TITLE AND SUBTITLE Fate of Thallium(I) in Reverse Osmosis and Chlorinated Water Matrices... osmosis (RO) and RO water with added chlorine (RO-Cl) was measured using inductively coupled plasma optical emission spectroscopy (ICP-OES) for a period of

  13. Life cycle assessment of drinking water: comparing conventional water treatment, reverse osmosis and mineral water in glass and plastic bottles

    OpenAIRE

    Garfi, Marianna; Cadena, Erasmo; Sanchez Ramos, David; Ferrer Martí, Ivet

    2016-01-01

    This study evaluated the environmental impacts caused by drinking water consumption in Barcelona (Spain) using the Life Cycle Assessment (LCA) methodology. Five different scenarios were compared: 1) tap water from conventional drinking water treatment; 2) tap water from conventional drinking water treatment with reverse osmosis at the water treatment plant; 3) tap water from conventional drinking water treatment with domestic reverse osmosis; 4) mineral water in plastic bottles, and 5) minera...

  14. Molecular level water and solute transport in reverse osmosis membranes

    Science.gov (United States)

    Lueptow, Richard M.; Shen, Meng; Keten, Sinan

    2015-11-01

    The water permeability and rejection characteristics of six solutes, methanol, ethanol, 2-propanol, urea, Na+, and Cl-, were studied for a polymeric reverse osmosis (RO) membrane using non-equilibrium molecular dynamics simulations. Results indicate that water flux increases with an increasing fraction of percolated free volume in the membrane polymer structure. Solute molecules display Brownian motion and hop from pore to pore as they pass through the membrane. The solute rejection depends on both the size of the solute molecule and the chemical interaction of the solute with water and the membrane. When the open spaces in the polymeric structure are such that solutes have to shed at least one water molecule from their solvation shell to pass through the membrane molecular structure, the water-solute pair interaction energy governs solute rejection. Organic solutes more easily shed water molecules than ions to more readily pass through the membrane. Hydrogen-bonding sites for molecules like urea also lead to a higher rejection. These findings underline the importance of the solute's solvation shell and solute-water-membrane chemistry in solute transport and rejection in RO membranes. Funded by the Institute for Sustainability and Energy at Northwestern with computing resources from XSEDE (NSF grant ACI-1053575).

  15. REMOVAL OF CHLORINATED AND BROMINATED ALKANES FROM DRINKING WATER USING REVERSE OSMOSIS

    Science.gov (United States)

    Membrane use in water treatment has historically focused on desalination. With the development of new membrane materials, attention began to focus on reverse osmosis and pervaporation as alternatives to traditional water treatment processes. This paper addresses the use of reve...

  16. REMOVAL OF CHLORINATED ALKENE SOLVENTS FROM DRINKING WATER BY VARIOUS REVERSE OSMOSIS MEMBRANES

    Science.gov (United States)

    Historically, membranes have been used to desalinate water. As new membrane materials are developed, traditional water treatment schemes may incorporate membrane technologies, such as reverse osmosis, to address a variety of new concerns such as low molecular weight volatile org...

  17. Reverse osmosis for wash water recovery in space vehicles.

    Science.gov (United States)

    Lawrence, R. W.; Saltonstall, C. W., Jr.

    1973-01-01

    Tests were carried out on both synthetic and real wash water derived from clothes laundry to determine the utility of reverse osmosis in recovering the water for recycle use. A blend membrane made from cellulose di- and triacetates, and a cross-linked cellulose acetate/methacrylate were evaluated. Both were found acceptable. A number of detergents were evaluated, including a cationic detergent, sodium dodecyl sulfate, potassium palmitate, and sodium dodecylbenzenesulfonate. The tests were all made at a temperature of 165 F to minimize microbial growth. Long-term (15 to 30 day) runs were made at 600 and 400 psi on laundry water which was pretreated either by alum addition and sand filtration or by filtration only through 0.5 micron filters. A 30-day run was made using a 2-in. diameter by 22-in. long spiral module at 400 psig with filtering as the pretreatment. The membrane fouling by colloidal matter was found to be controllable. The unit produced initially 55 gal/day and 27 gal/day after 30 days.

  18. MODIFIED REVERSE OSMOSIS SYSTEM FOR TREATMENT OF PRODUCED WATERS

    Energy Technology Data Exchange (ETDEWEB)

    T.M. Whitworth; Liangxiong Li

    2002-09-15

    This report describes work performed during the first year of the project ''Modified Reverse Osmosis System for Treatment of Produced Waters.'' This research project has two objectives. The first objective is to test the use of clay membranes in the treatment of produced waters by reverse osmosis. The second objective is to test the ability of a system patented by the New Mexico Tech Research Foundation to remove salts from reverse osmosis waste streams as a solid. We performed 12 experiments using clay membranes in cross-flow experimental cells. We found that, due to dispersion in the porous frit used adjacent to the membrane, the concentration polarization layer seems to be completely (or nearly completely) destroyed at low flow rates. This observation suggests that clay membranes used with porous frit material many reach optimum rejection rates at lower pumping rates than required for use with synthetic membranes. The solute rejection efficiency decreases with increasing solution concentration. For the membranes and experiments reported here, the rejection efficiency ranged from 71% with 0.01 M NaCl solution down to 12% with 2.3 M NaCl solution. More compacted clay membranes will have higher rejection capabilities. The clay membranes used in our experiments were relatively thick (approximately 0.5 mm). The active layer of most synthetic membranes is only 0.04 {micro}m (0.00004 mm), approximately 1250 times thinner than the clay membranes used in these experiments. Yet clay membranes as thin as 12 {micro}m have been constructed (Fritz and Eady, 1985). Since Darcy's law states that the flow through a material of constant permeability is inversely proportional to it's the material's thickness, then, based on these experimental observations, a very thin clay membrane would be expected to have much higher flow rates than the ones used in these experiments. Future experiments will focus on testing very thin clay membranes. The

  19. Reverse Osmosis

    Indian Academy of Sciences (India)

    /fulltext/reso/016/12/1333-1336. Keywords. Osmos is ; reverseos mosis; desalinatiion; seawater; water purification. Author Affiliations. Sudhakar M Rao1. Department of Civil Engineering, Indian Institute of Science, Bangalore 560012, India.

  20. Obtaining water with a high degree of purity by using reverse osmosis

    Directory of Open Access Journals (Sweden)

    Nicolae Chirilă

    2011-12-01

    Full Text Available In this paper, we used the method of reverse osmosis in order to obtain water with a high degree of purity. For this aim, we used the TKA 20-120ECO device. We completed physic-chemical determinations for the water of supply, as well as for the water obtained after the osmosis process. The results that we obtained are relevant and interesting.

  1. Indirect desalination of Red Sea water with forward osmosis and low pressure reverse osmosis for water reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2011-10-01

    The use of energy still remains the main component of the costs of desalting water. Forward osmosis (FO) can help to reduce the costs of desalination, and extracting water from impaired sources can be beneficial in this regard. Experiments with FO membranes using a secondary wastewater effluent as a feed water and Red Sea water as a draw solution demonstrated that the technology is promising. FO coupled with low pressure reverse osmosis (LPRO) was implemented for indirect desalination. The system consumes only 50% (~1.5 kWh/m3) of the energy used for high pressure seawater RO (SWRO) desalination (2.5-4 kWh/m3), and produces a good quality water extracted from the impaired feed water. Fouling of the FO membranes was not a major issue during long-term experiments over 14 days. After 10 days of continuous FO operation, the initial flux declined by 28%. Cleaning the FO membranes with air scouring and clean water recovered the initial flux by 98.8%. A cost analysis revealed FO per se as viable technology. However, a minimum average FO flux of 10.5 L/m2-h is needed to compete with water reuse using UF-LPRO, and 5.5 L/m2-h is needed to recover and desalinate water at less cost than SWRO. © 2011 Elsevier B.V.

  2. MODIFIED REVERSE OSMOSIS SYSTEM FOR TREATMENT OF PRODUCED WATERS

    Energy Technology Data Exchange (ETDEWEB)

    Robert L. Lee; Junghan Dong

    2004-06-03

    This final report of ''Modified Reverse Osmosis System for Treatment of Produced Water,'' DOE project No. DE-FC26-00BC15326 describes work performed in the third year of the project. Several good results were obtained, which are documented in this report. The compacted bentonite membranes were replaced by supported bentonite membranes, which exhibited the same salt rejection capability. Unfortunately, it also inherited the clay expansion problem due to water invasion into the interlayer spaces of the compacted bentonite membranes. We noted that the supported bentonite membrane developed in the project was the first of its kind reported in the literature. An {alpha}-alumina-supported MFI-type zeolite membrane synthesized by in-situ crystallization was fabricated and tested. Unlike the bentonite clay membranes, the zeolite membranes maintained stability and high salt rejection rate even for a highly saline solution. Actual produced brines from gas and oil fields were then tested. For gas fields producing brine, the 18,300 ppm TDS (total dissolved solids) in the produced brine was reduced to 3060 ppm, an 83.3% rejection rate of 15,240 ppm salt rejection. For oilfield brine, while the TDS was reduced from 181,600 ppm to 148,900 ppm, an 18% rejection rate of 32,700 ppm reduction, the zeolite membrane was stable. Preliminary results show the dissolved organics, mainly hydrocarbons, did not affect the salt rejection. However, the rejection of organics was inconclusive at this point. Finally, the by-product of this project, the {alpha}-alumina-supported Pt-Co/Na Y catalytic zeolite membrane was developed and demonstrated for overcoming the two-step limitation of nonoxidation methane (CH{sub 4}) conversion to higher hydrocarbons (C{sub 2+}) and hydrogen (H{sub 2}). Detailed experiments to obtain quantitative results of H{sub 2} generation for various conditions are now being conducted. Technology transfer efforts included five manuscripts submitted to

  3. Application of pressure assisted forward osmosis for water purification and reuse of reverse osmosis concentrate from a water reclamation plant

    KAUST Repository

    Jamil, Shazad

    2016-07-26

    The use of forward osmosis (FO) is growing among the researchers for water desalination and wastewater treatment due to use of natural osmotic pressure of draw solute. In this study pressure assisted forward osmosis (PAFO) was used instead of FO to increase the water production rate. In this study a low concentration of draw solution (0.25 M KCl) was applied so that diluted KCl after PAFO operation can directly be used for fertigation. The performance of PAFO was investigated for the treatment of reverse osmosis concentrate (ROC) from a water reclamation plant. The water production in PAFO was increased by 9% and 29% at applied pressure of 2 and 4 bars, respectively, to feed side based on 90 h of experiments. Granular activated carbon (GAC) pretreatment and HCl softening were used to reduce organic fouling and scaling prior to application of PAFO. It reduced total organic carbon (TOC) and total inorganic carbon (TIC) by around 90% and 85%, respectively from untreated ROC. Subsequently, this led to an increase in permeate flux. In addition, GAC pretreatment adsorbed 12 out of 14 organic micropollutants tested from ROC to below detection limit. This application enabled to minimise the ROC volume with a sustainable operation and produced high quality and safe water for discharge or reuse. The draw solution (0.25 M KCl) used in this study was diluted to 0.14 M KCl, which is a suitable concentration (10 kg/m3) for fertigation, due to water transport from feed solution. © 2016 Elsevier B.V.

  4. Gray water recycle: Effect of pretreatment technologies on low pressure reverse osmosis treatment

    Science.gov (United States)

    Gray water can be a valuable source of water when properly treated to reduce the risks associated with chemical and microbial contamination to acceptable levels for the intended reuse application. In this study, the treatment of gray water using low pressure reverse osmosis (RO) filtration after pre...

  5. Investigation of microbial communities on reverse osmosis membranes used for process water production

    NARCIS (Netherlands)

    Bereschenko, L.A.; Stams, A.J.M.; Heilig, G.H.J.; Euverink, G.J.W.; Nederlof, M.M.; Loosdrecht, M.C.M.

    2007-01-01

    In the present study, the diversity and the phylogenetic affiliation of bacteria in a biofouling layer on reverse osmosis (RO) membranes were determined. Fresh surface water was used as a feed in a membrane-based water purification process. Total DNA was extracted from attached cells from feed

  6. Sensory quality of drinking water produced by reverse osmosis membrane filtration followed by remineralisation

    NARCIS (Netherlands)

    Vingerhoeds, M.H.; Nijenhuis, M.A.; Ruepert, N.; Bredie, W.L.P.; Kremer, S.

    2016-01-01

    Membrane filtration of ground, surface, or sea water by reverse osmosis results in permeate, which is almost free from minerals. Minerals may be added afterwards, not only to comply with (legal) standards and to enhance chemical stability, but also to improve the taste of drinking water made from

  7. Sensory quality of drinking water produced by reverse osmosis membrane filtration followed by remineralisation

    DEFF Research Database (Denmark)

    Vingerhoeds, Monique H.; Nijenhuis-de Vries, Mariska A.; Ruepert, Nienke

    2016-01-01

    Membrane filtration of ground, surface, or sea water by reverse osmosis results in permeate, which is almost free from minerals. Minerals may be added afterwards, not only to comply with (legal) standards and to enhance chemical stability, but also to improve the taste of drinking water made from...

  8. Reverse Osmosis Optimization

    Energy Technology Data Exchange (ETDEWEB)

    McMordie Stoughton, Kate; Duan, Xiaoli; Wendel, Emily M.

    2013-08-26

    This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). ¬The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.¬

  9. Reverse Osmosis Optimization

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-08-01

    This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.

  10. Forward osmosis for the treatment of reverse osmosis concentrate from water reclamation: process performance and fouling control.

    Science.gov (United States)

    Kazner, C; Jamil, S; Phuntsho, S; Shon, H K; Wintgens, T; Vigneswaran, S

    2014-01-01

    While high quality water reuse based on dual membrane filtration (membrane filtration or ultrafiltration, followed by reverse osmosis) is expected to be progressively applied, treatment and sustainable management of the produced reverse osmosis concentrate (ROC) are still important issues. Forward osmosis (FO) is a promising technology for maximising water recovery and further dewatering ROC so that zero liquid discharge is produced. Elevated concentrations of organic and inorganic compounds may act as potential foulants of the concentrate desalting system, in that they consist of, for example, FO and a subsequent crystallizer. The present study investigated conditions under which the FO system can serve as concentration phase with the focus on its fouling propensity using model foulants and real ROC. Bulk organics from ROC consisted mainly of humic acids (HA) and building blocks since wastewater-derived biopolymers were retained by membrane filtration or ultrafiltration. Organic fouling of the FO system by ROC-derived bulk organics was low. HA was only adsorbed moderately at about 7% of the initial concentration, causing a minor flux decline of about 2-4%. However, scaling was a major impediment to this process if not properly controlled, for instance by pH adjustment or softening.

  11. Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

    Science.gov (United States)

    Hall, J. B., Jr.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

  12. Removal of radionuclides in drinking water by membrane treatment using ultrafiltration, reverse osmosis and electrodialysis reversal.

    Science.gov (United States)

    Montaña, M; Camacho, A; Serrano, I; Devesa, R; Matia, L; Vallés, I

    2013-11-01

    A pilot plant had been built to test the behaviour of ultrafiltration (UF), reverse osmosis (RO), and electrodialysis reversal (EDR) in order to improve the quality of the water supplied to Barcelona metropolitan area from the Llobregat River. This paper presents results from two studies to reduce natural radioactivity. The results from the pilot plant with four different scenarios were used to design the full-scale treatment plant built (SJD WTP). The samples taken at different steps of the treatment were analysed to determine gross alpha, gross beta and uranium activity. The results obtained revealed a significant improvement in the radiological water quality provided by both membrane techniques (RO and EDR showed removal rates higher than 60%). However, UF did not show any significant removal capacity for gross alpha, gross beta or uranium activities. RO was better at reducing the radiological parameters studied and this treatment was selected and applied at the full scale treatment plant. The RO treatment used at the SJD WTP reduced the concentration of both gross alpha and gross beta activities and also produced water of high quality with an average removal of 95% for gross alpha activity and almost 93% for gross beta activity at the treatment plant. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Efficiently Combining Water Reuse and Desalination through Forward Osmosis-Reverse Osmosis (FO-RO) Hybrids: A Critical Review.

    Science.gov (United States)

    Blandin, Gaetan; Verliefde, Arne R D; Comas, Joaquim; Rodriguez-Roda, Ignasi; Le-Clech, Pierre

    2016-07-01

    Forward osmosis (FO) is a promising membrane technology to combine seawater desalination and water reuse. More specifically, in a FO-reverse osmosis (RO) hybrid process, high quality water recovered from the wastewater stream is used to dilute seawater before RO treatment. As such, lower desalination energy needs and/or water augmentation can be obtained while delivering safe water for direct potable reuse thanks to the double dense membrane barrier protection. Typically, FO-RO hybrid can be a credible alternative to new desalination facilities or to implementation of stand-alone water reuse schemes. However, apart from the societal (public perception of water reuse for potable application) and water management challenges (proximity of wastewater and desalination plants), FO-RO hybrid has to overcome technical limitation such as low FO permeation flux to become economically attractive. Recent developments (i.e., improved FO membranes, use of pressure assisted osmosis, PAO) demonstrated significant improvement in water flux. However, flux improvement is associated with drawbacks, such as increased fouling behaviour, lower rejection of trace organic compounds (TrOCs) in PAO operation, and limitation in FO membrane mechanical resistance, which need to be better considered. To support successful implementation of FO-RO hybrid in the industry, further work is required regarding up-scaling to apprehend full-scale challenges in term of mass transfer limitation, pressure drop, fouling and cleaning strategies on a module scale. In addition, refined economics assessment is expected to integrate fouling and other maintenance costs/savings of the FO/PAO-RO hybrid systems, as well as cost savings from any treatment step avoided in the water recycling.

  14. Adsorption of Estrone on nanofiltration and reverse osmosis membranes in water and wastewater treatment

    OpenAIRE

    Nghiem, D. L.; Schaefer, Andrea; Waite, T. D.

    2002-01-01

    Adsorption of the trace contaminant estrone, a natural hormone and commonly abundant in surface waters and in treated as well as untreated wastewaters, to eight commercial nanofiltration (NF) and reverse osmosis (RO) membranes was investigated under welldefined conditions. Experiments were conducted in stainless steel stirred cells by spiking trace levels (100ng.L-1) of estrone into five different matrices, namely MilliQ water, a bicarbonate solution, synthetic natural waters containing natur...

  15. Rejection of Emerging Organic Contaminants by Nanofiltration and Reverse Osmosis Membranes : Effects of Fouling, Modelling and Water Reuse

    NARCIS (Netherlands)

    Yangali Quintanilla, V.

    2010-01-01

    The book contains a description of the presence of micropollutants (medicines, hormones, pesticides) in surface water and shows that conventional water treatment poorly removes micropollutants. Nanofiltration and reverse osmosis are more appropriate technologies; however removals can vary depending

  16. Experimental Investigation of Solar Powered Reverse Osmosis ...

    African Journals Online (AJOL)

    fire7-

    Pollution and over exploitation of groundwater aquifer and surface water have led to a decrease ... favoring for implementing solar photovoltaic (PV) reverse osmosis (RO) desalination technology. The fast development of solar energy, especially photovoltaic, ... Among desalination technologies, reverse osmosis is rapidly.

  17. Data on daily fluoride intake based on drinking water consumption prepared by household desalinators working by reverse osmosis process

    Directory of Open Access Journals (Sweden)

    Vahid Noroozi Karbasdehi

    2016-09-01

    Full Text Available In this data article, we evaluated the daily fluoride contents in 20 household desalinators working by reverse osmosis (RO1 Reverse Osmosis. process in Bushehr, Iran. The concentration levels of fluoride in inlet and outlet waters were determined by the standard SPADNS method using a spectrophotometer (M501 Single Beam Scanning UV/VIS, UK. The fluoride content in outlet waters were compared with EPA and WHO guidelines for drinking water.

  18. Data on daily fluoride intake based on drinking water consumption prepared by household desalinators working by reverse osmosis process

    OpenAIRE

    Karbasdehi, Vahid Noroozi; Dobaradaran, Sina; Esmaili, Abdolhamid; Mirahmadi, Roghayeh; Ghasemi, Fatemeh Faraji; Keshtkar, Mozhgan

    2016-01-01

    In this data article, we evaluated the daily fluoride contents in 20 household desalinators working by reverse osmosis (RO)1 Reverse Osmosis. process in Bushehr, Iran. The concentration levels of fluoride in inlet and outlet waters were determined by the standard SPADNS method using a spectrophotometer (M501 Single Beam Scanning UV/VIS, UK). The fluoride content in outlet waters were compared with EPA and WHO guidelines for drinking water.

  19. EFFICIENCY OF DOMESTIC REVERSE OSMOSIS IN REMOVAL OF TRIHALOMETHANES FROM DRINKING WATER

    Directory of Open Access Journals (Sweden)

    S. Mazloomi ، R. Nabizadeh ، S. Nasseri ، K. Naddafi ، S. Nazmara ، A. H. Mahvi

    2009-10-01

    Full Text Available The reaction of disinfectants with natural organic matters existing in water lead to the formation of Disinfection By-Products. Potentially hazardous and carcinogenic characteristics of trihalomethanes (THMs are recognized. Thus removal of THMs or its precursors are necessary for human health. The aim of this study was to study the efficiency of domestic reverse osmosis (RO in removal of trihalomethanes from drinking water. A pilot scale of RO system with Polyamide membrane as Spiral-Wound, Tape wrapping module was used. Feed solution was made by using of pure chloroform. The samples containing chloroform were analyzed using a gas chromatograph equipped with a flame ionization detector. By increasing the flow, the removal rate of chloroform decreased and with declining removal of EC, the removal of chloroform declined too. In this research, at the worst condition, the efficiency of the pilot scale reverse osmosis reached to 80 % removal of chloroform.

  20. Addressing reverse osmosis fouling within water reclamation--a side-by-side comparison of low-pressure membrane pretreatments.

    Science.gov (United States)

    Kent, Fraser C; Farahbakhsh, Khosrow

    2011-06-01

    A tertiary membrane filtration (TMF) pilot operating on secondary effluent and a membrane bioreactor (MBR) were setup in a side-by-side study as pretreatments for two identical reverse osmosis pilot systems. The water quality of the permeate from both low-pressure membrane pretreatment systems and the fouling rate of the reverse osmosis systems were compared to assess the capabilities of the two low-pressure membrane pretreatments to prevent organic fouling of the reverse osmosis systems. Both pretreatment pilots were setup using typical operating conditions (i.e., solids retention time and mixed-liquor suspended solids). A consistent difference in water quality and reverse osmosis performance was demonstrated during the 12-month study. The MBR permeate consistently had significantly lower total organic carbon (TOC) and chemical oxygen demand concentrations, but higher color and specific UV absorbance compared with the permeate from the TMF pretreatment. The pretreatment with the MBR gave an average reverse osmosis fouling rate over the entire study (0.27 Lmh/bar.month) that was less than half of the value found for the reverse osmosis with TMF pretreatment (0.60 Lmh/bar.month). A correlation of reverse osmosis feed TOC concentration with average reverse osmosis fouling rate also was established, independent of the pretreatment method used. Results from a cleaning analysis, energy dispersive spectroscopy, and fourier transformed infrared reflectometry confirmed that the foulants were primarily organic in nature. It is concluded that, for this type of application and setup, MBR systems present an advantage over tertiary membrane polishing of secondary effluent for reverse osmosis pretreatment.

  1. Byproduct recovery from reclaimed water reverse osmosis concentrate using lime and soda-ash treatment.

    Science.gov (United States)

    Mohammadesmaeili, Farah; Badr, Mostafa Kabiri; Abbaszadegan, Morteza; Fox, Peter

    2010-04-01

    Lime and soda-ash softening of reclaimed water reverse osmosis concentrates as a pretreatment step for concentration by seawater reverse osmosis was the focus of this study. The objectives were removal of the potential fouling minerals of calcium, magnesium, and silica by selective precipitation, while producing byproducts with potential resale value. Three different bench-scale lime-soda processes were evaluated. The traditional method produced low-quality magnesium hydroxide [Mg(OH)2] and calcium carbonate (CaCO3) byproducts. A modified process with pre-acidification to eliminate carbonate removed 98 to 99% of calcium and magnesium and produced CaCO3 that was > 94% pure. To prevent the contamination of byproducts with calcium sulfate (CaSO4) in high-sulfate concentrates, a CaSO4 crystallization step was added successfully to the modified process to precipitate CaSO4 before Mg(OH)2 precipitation and produce gypsum that was 92% pure. The modified lime-soda process also removed 94 to 97% silica, 72 to 77% barium, and 95 to 96% strontium, which are known as reverse osmosis membrane foulants.

  2. Forward Osmosis/Low Pressure Reverse Osmosis for Water Reuse: Removal of Organic Micropollutants, Fouling and Cleaning

    KAUST Repository

    Linares, Rodrigo

    2011-07-01

    Forward osmosis (FO) is a natural process in which a solution with high concentration of solutes is diluted when being in contact, through a semipermeable membrane, with a low concentration solution. This osmotic process has been demonstrated to be efficient to recover wastewater effluents while diluting a saline draw solution. Nevertheless, the study of the removal of micropollutants by FO is barely described in the literature. This research focuses on the removal of these substances spiked in a secondary wastewater effluent, while diluting water from the Red Sea, generating feed water that can be desalinated with a low pressure reverse osmosis (LPRO) system. Another goal of this work is to characterize the fouling of the FO membrane, and its effect on micropollutants rejection, as well as the membrane cleaning efficiency of different methods. When considering only FO with a clean membrane, the rejection of the hydrophilic neutral compounds was between 48.6% and 84.7%, for the hydrophobic neutrals the rejection ranged from 40.0% to 87.5%, and for the ionic compounds the rejections were between 92.9% and 96.5%. With a fouled membrane, the rejections were between 44.6% to 95.2%, 48.7% to 91.5% and 96.9% to 98.6%, respectively. These results suggest that, except for the hydrophilic neutral compounds, the rejection of the micropollutants is increased by the fouling layer, possibly due to the higher hydrophilicity of the FO fouled membrane compared to the clean one, the increased adsorption capacity and reduced mass transport capacity, membrane swelling, and the higher negative charge of the surface, related to the foulants. However, when coupled with low pressure reverse osmosis, the rejections for both, the clean and fouled membrane, increased above 98%. The fouling layer, after characterizing the wastewater effluent and the concentrated wastewater after the FO process, proved to be composed of biopolymers, which can be removed with air scouring during short periods

  3. Review of Brackish water reverse osmosis (BWRO) system designs

    Energy Technology Data Exchange (ETDEWEB)

    Alghoul, M.A.; Poovanaesvaran, P.; Sopian, K.; Sulaiman, M.Y. [Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2009-12-15

    Brackish water are any water sources with TDS between 1000 and 15 000 mg/L. Brackish water cannot be consumed by us directly due to its high salinity. According to World Health Organization (WHO), water with salinity below 500 mg/L is acceptable as drinking water. There are quite a large number of research that had been done on BWRO. Each of them has agreed with a common design on optimum BWRO design with a slight modification in order to improve more and make a better BWRO system. BWRO systems which have been tested in real situation agree that the single stage system with module connected to reject water is the most optimum system both economically and environmentally. There is some improvement done to the design by using SWRO membrane at the second stage. This improvement increases recovery rate to about 83% and reduces boron concentration at the same time. Another design is by using hybrid combination of ultra-low and conventional RO membranes. Hybrid improves permeate quality. It is also possible to create a hybrid array by mixing membrane element types within a pressure vessel itself. Co-operating an efficient module arrangement into a complete BWRO system will reduce energy consumption. Energy-recovery device is a component that must be included in any small or large-scale systems. A small-scale RO system, without energy recovery, would typically consume two to three times more energy. This will be more for large-scale systems. While single stage system with module connected to reject water is preferred by researchers who have done real environment testing, simulation prefers to add another membrane to the reject water of the second module. This system is yet to be tested in real environment to prove its standing. (author)

  4. Evaluation of the use of reverse osmosis to eliminate natural radionuclides from water samples.

    Science.gov (United States)

    Nieto, Antonio; Palomo, Marta; Ruana, Josep; Peñalver, Alejandra; Aguilar, Carme; Borrull, Francesc

    2013-12-01

    The objective of drinking water treatment plants (DWTP) is to supply the population with tap water that is in optimal condition and in compliance with water quality regulations. In the DWTP of L'Ampolla (Tarragona, Spain), slightly high values of gross alpha activity and the amount of salts in the raw water have been observed. Conventional treatment has reduced these levels only minimally. This study tested a tertiary treatment based on reverse osmosis is tested in an industrial pilot plant (240 m3/day) The efficiency of this pilot plant to reduce the gross alpha and beta activities and the activity of some individual radioisotopes (U(238), U(234), U(235) and Ra(226)) was tested. Results showed that the elimination of alpha emitters was greater than 90%, whereas the elimination of beta emitters was about 35%. Overall, the data provided evidence that the pilot plant is effective for removing different radionuclides that can be present in the incoming water treated. Therefore, tertiary treatment based on reverse osmosis has a positive effect in water quality.

  5. Sensory quality of drinking water produced by reverse osmosis membrane filtration followed by remineralisation.

    Science.gov (United States)

    Vingerhoeds, Monique H; Nijenhuis-de Vries, Mariska A; Ruepert, Nienke; van der Laan, Harmen; Bredie, Wender L P; Kremer, Stefanie

    2016-05-01

    Membrane filtration of ground, surface, or sea water by reverse osmosis results in permeate, which is almost free from minerals. Minerals may be added afterwards, not only to comply with (legal) standards and to enhance chemical stability, but also to improve the taste of drinking water made from permeate. Both the nature and the concentrations of added minerals affect the taste of the water and in turn its acceptance by consumers. The aim of this study was to examine differences in taste between various remineralised drinking waters. Samples selected varied in mineral composition, i.e. tap water, permeate, and permeate with added minerals (40 or 120 mg Ca/L, added as CaCO3, and 4 or 24 mg Mg/L added as MgCl2), as well as commercially available bottled drinking waters, to span a relevant product space in which the remineralised samples could be compared. All samples were analysed with respect to their physical-chemical properties. Sensory profiling was done by descriptive analysis using a trained panel. Significant attributes included taste intensity, the tastes bitter, sweet, salt, metal, fresh and dry mouthfeel, bitter and metal aftertaste, and rough afterfeel. Total dissolved solids (TDS) was a major determinant of the taste perception of water. In general, lowering mineral content in drinking water in the range examined (from water from fresh towards bitter, dry, and rough sensations. In addition, perceived freshness of the waters correlated positively with calcium concentration. The greatest fresh taste was found for water with a TDS between 190 and 350 mg/L. Remineralisation of water after reverse osmosis can improve drinking quality significantly. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Reverse osmosis for water purification and reuse in the biotechnological industry: Process design, operation and economic guidelines

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil; S.B.A. Udugama, Isuru; Mitic, Aleksandar

    2017-01-01

    load on a wastewater treatment plant (WWTP), thereby investigating opportunities for process water reuse. In this case, a recovery unitis studied, where purification and concentration generates large volumes of wastewater. Reverse osmosis (RO) could ensure that the desired drinking water quality could...... be achieved and would enable re-use of the water in the production site for different economic purposes....

  7. Desalination of Red Sea water using both electrodialysis and reverse osmosis as complementary methods

    Directory of Open Access Journals (Sweden)

    E.A. Abdel-Aal

    2015-03-01

    Full Text Available Desalination process separates nearly salt free water from sea or brackish water. So, desalination process is becoming a solution for water scarcity all over the world. Two membrane methods of water desalination namely electrodialysis (ED and reverse osmosis (RO are used in this study as complementary methods. The results show that both ED and RO can be used as integrated system. This system is economic and cost effective compared with each individual method provided using the ED system before the RO. In this study, it was approved that seawater can be used as it is an electrolyte. TDS of Red Sea water was decreased from 42070 ppm to 2177 ppm achieving 94.8% removal efficiency using ED for half of its optimum time. Total removal efficiency of 99.4% can be obtained using the combined system of ED and RO.

  8. Performance Study of Reverse Osmosis Plants for Water Desalination in Bandar-Lengeh, Iran

    Directory of Open Access Journals (Sweden)

    Alireza Zirakrad

    2013-04-01

    Full Text Available Introduction: Reverse osmosis (RO is best known for its use in desalination (removing the salt from seawater to get fresh water, but since the early 1970s it has also been used to purify fresh water for medical, industrial, and domestic applications. The aim of this research was the performance study of reverse osmosis plants for water desalination in Bandar-Lengeh, Iran. Materials and Methods: In this study the concentrations of a number of physical, chemical and biological quality parameters in raw and treated water of Bandar-Lengeh water Desalination Plants were determined and Performance of RO plants for seawater and costal groundwater desalination were studied. There are two desalination plants in Bandar-Lengeh. Water from these plants are used for municipal supply. Total production capacity of the two RO desalination plants is 8000 m3/d. Results: The results of this study showed average values of TDS, Sodium, Chloride, Sulfate, diatomaceous and Nematodes in seawater were 37749 mg/l; 9715 mg/l; 22020 mg/l; 3067 mg/l; 24337 N/100ml and 5 N/100ml and in treated water were 1233 mg/l; 436 mg/l; 710 mg/l; 58 mg/l, 0 N/100ml and 0 N/100ml, respectively. Also the results showed average values of TDS, Sodium, Chloride and Sulfate in coastal ground water were 37131 mg/l; 9303 mg/l; 21072 mg/l; 3745 mg/l; and in treated water were 687mg/l; 253 mg/l; 389 mg/l; 19 mg/l, respectively. Conclusion: The results showed the quality of feed water and pretreatment plays an extremely important role in operational problems such as fouling of RO systems.

  9. Phosphorus and water recovery by a novel osmotic membrane bioreactor-reverse osmosis system.

    Science.gov (United States)

    Luo, Wenhai; Hai, Faisal I; Price, William E; Guo, Wenshan; Ngo, Hao H; Yamamoto, Kazuo; Nghiem, Long D

    2016-01-01

    An osmotic membrane bioreactor-reverse osmosis (OMBR-RO) hybrid system integrated with periodic microfiltration (MF) extraction was evaluated for simultaneous phosphorus and clean water recovery from raw sewage. In this hybrid system, the forward osmosis membrane effectively retained inorganic salts and phosphate in the bioreactor, while the MF membrane periodically bled them out for phosphorus recovery with pH adjustment. The RO process was used for draw solute recovery and clean water production. Results show that phosphorus recuperation from the MF permeate was most effective when the solution pH was adjusted to 10, whereby the recovered precipitate contained 15-20% (wt/wt) of phosphorus. Periodic MF extraction also limited salinity build-up in the bioreactor, resulting in a stable biological performance and an increase in water flux during OMBR operation. Despite the build-up of organic matter and ammonia in the draw solution, OMBR-RO allowed for the recovery of high quality reused water. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  10. An investigation of desalination by nanofiltration, reverse osmosis and integrated (hybrid NF/RO) membranes employed in brackish water treatment.

    Science.gov (United States)

    Talaeipour, M; Nouri, J; Hassani, A H; Mahvi, A H

    2017-01-01

    As an appropriate tool, membrane process is used for desalination of brackish water, in the production of drinking water. The present study aims to investigate desalination processes of brackish water of Qom Province in Iran. This study was carried out at the central laboratory of Water and Wastewater Company of the studied area. To this aim, membrane processes, including nanofiltration (NF) and reverse osmosis (RO), separately and also their hybrid process were applied. Moreover, water physical and chemical parameters, including salinity, total dissolved solids (TDS), electric conductivity (EC), Na+1 and Cl-1 were also measured. Afterward, the rejection percent of each parameter was investigated and compared using nanofiltration and reverse osmosis separately and also by their hybrid process. The treatment process was performed by Luna domestic desalination device, which its membrane was replaced by two NF90 and TW30 membranes for nanofiltration and reverse osmosis processes, respectively. All collected brackish water samples were fed through membranes NF90-2540, TW30-1821-100(RO) and Hybrid (NF/RO) which were installed on desalination household scale pilot (Luna water 100GPD). Then, to study the effects of pressure on permeable quality of membranes, the simulation software model ROSA was applied. Results showed that percent of the salinity rejection was recorded as 50.21%; 72.82 and 78.56% in NF, RO and hybrid processes, respectively. During the study, in order to simulate the performance of nanofiltartion, reverse osmosis and hybrid by pressure drive, reverse osmosis system analysis (ROSA) model was applied. The experiments were conducted at performance three methods of desalination to remove physic-chemical parameters as percentage of rejections in the pilot plant are: in the NF system the salinity 50.21, TDS 43.41, EC 43.62, Cl 21.1, Na 36.15, and in the RO membrane the salinity 72.02, TDS 60.26, EC 60.33, Cl 43.08, Na 54.41. Also in case of the rejection in

  11. The effect of flow and chemical corrosion in reverse osmosis over desalinated water

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jae [Chunnam National Univ., Gwangju (Korea, Republic of); Pak, Byung Gu [Doosan Heavy Industry Co., Tongyoung (Korea, Republic of)

    2015-12-15

    Desalinated water produced by a reverse osmosis (RO) filtering method forms about 22% of total production of desalinated water in the world. However, the RO environment is very corrosive due to the presence of various chemicals for water treatment and the flow of sand particles leading to corrosion. Recently, there has been much effort to substitute cheaper and more corrosion resistant stainless steels for copper based alloys as a valve material in RO. Nevertheless, the effects of chemicals and particles on the corrosion of stainless steels have rarely been studied. Erosion phenomenon was detected under the condition with the flow rate of more than 8ms{sup -1} in spite of the absence of sand particles. In seawater containing sand particles, the erosion in stainless steels was accelerated further.

  12. Reverse Osmosis Filter Use and High Arsenic Levels in Private Well Water

    Science.gov (United States)

    George, Christine M.; Smith, Allan H.; Kalman, David A.; Steinmaus, Craig M.

    2013-01-01

    Inorganic arsenic causes cancer, and millions of people worldwide are exposed to arsenic-contaminated water. Regulatory standards for arsenic levels in drinking water generally do not apply to private domestic wells. Reverse osmosis (RO) units commonly are used by well owners to reduce arsenic concentrations, but may not always be effective. In a survey of 102 homes in Nevada, 19 used RO devices. Pre- and post-RO filtration arsenic concentrations averaged 443 μg/l and 87 μg/l, respectively. The average absolute and percent reductions in arsenic concentrations after filtration were 356 μg/l and 79%, respectively. Postfiltration concentrations were higher than 10 μg/l in 10 homes and higher than 100 μg/l in 4 homes. These findings provide evidence that RO filters do not guarantee safe drinking water and, despite regulatory standards, some people continue to be exposed to very high arsenic concentrations. PMID:17867571

  13. Nanofiltration vs. reverse osmosis for the removal of emerging organic contaminants in water reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2011-10-01

    Reverse osmosis (RO) in existing water reuse facilities is a water industry standard. However, that approach may be questioned taking into consideration that "tight" NF can be equal or "better" than RO. NF can achieve the same removals of RO membranes when dealing with emerging organic contaminants (pharmaceuticals, pesticides, endocrine disruptors and others). Experiments using 18 emerging contaminants were performed using membranes NF200 and NF90 at bench-scale units, and for a more complete study, results of NF and RO pilot and full-scale experiments where compared to our experimental results. The removal results showed that NF can remove many emerging contaminants. The average removal by tight NF was 82% for neutral contaminants and 97% for ionic contaminants. The average removal by RO was 85% for neutral contaminants and 99% for ionic contaminants. Aquifer recharge and recovery (ARR) followed by NF can effectively remove emerging contaminants with removals over 90% when loose NF membranes are used.

  14. Biological support media influence the bacterial biofouling community in reverse osmosis water reclamation demonstration plants.

    Science.gov (United States)

    Ferrera, Isabel; Mas, Jordi; Taberna, Elisenda; Sanz, Joan; Sánchez, Olga

    2015-01-01

    The diversity of the bacterial community developed in different stages of two reverse osmosis (RO) water reclamation demonstration plants designed in a wastewater treatment plant (WWTP) in Tarragona (Spain) was characterized by applying 454-pyrosequencing of the 16S rRNA gene. The plants were fed by secondary treated effluent to a conventional pretreatment train prior to the two-pass RO system. Plants differed in the material used in the filtration process, which was sand in one demonstration plant and Scandinavian schists in the second plant. The results showed the presence of a highly diverse and complex community in the biofilms, mainly composed of members of the Betaproteobacteria and Bacteroidetes in all stages, with the presence of some typical wastewater bacteria, suggesting a feed water origin. Community similarities analyses revealed that samples clustered according to filter type, highlighting the critical influence of the biological supporting medium in biofilm community structure.

  15. Speech and Language Disorders in a Dialysis Encephalopathy Patient and the Effect of Desferrioxamine and Reverse-Osmosis Water Treatment.

    Science.gov (United States)

    Lehtihalmes, Matti; And Others

    Dialysis encephalopathy is a progressive neurological disorder occurring after long-term hemodialysis in some renal failure patients. Accumulation of aluminum in the brain is suspected as its cause, and the use of reverse osmosis of the dialysis water and administration of desferrioxamine to the patient have been successful in reducing the…

  16. Energy consumption in membrane capacitive deionization for different water recoveries and flow rates, and comparison with reverse osmosis

    NARCIS (Netherlands)

    Zhao, R.; Porada, S.; Biesheuvel, P.M.; Wal, van der A.

    2013-01-01

    Membrane capacitive deionization (MCDI) is a non-faradaic, capacitive technique for desalinating brackish water by adsorbing ions in charged porous electrodes. To compete with reverse osmosis, the specific energy consumption of MCDI needs to be reduced to less than 1 kWh per m3 of freshwater

  17. A Comparison of Water Diffusion in Polymer Based Fuel Cell and Reverse Osmosis Membrane Materials

    Science.gov (United States)

    Soles, Christopher; Frieberg, Bradley; Tarver, Jacob; Tyagi, Madhusudan; Jeong, Cheol; Chan, Edwin; Stafford, Christopher

    Hydrated polymer membranes are critical in both fuel cells and water filtration and desalination. In both of these applications the membrane function (selectively transporting or separating ions) is coupled with the transport of water through the membrane. There is a significant need to understand the nature by which the water and ions distribute and move through these membranes. This presentation compares the transport mechanisms in in an ion containing block copolymer alkaline fuel cell membrane with that of a polyamide membrane that is used as the active layer in a reverse osmosis water desalination membrane. Small angle neutron scattering measurements are used to locally probe how water swells the different materials and quantitatively describe the distribution of water within the membrane microstructures. Quasielastic neutron scattering measurements are then used to separate the polymer dynamics of the host membranes from the dynamics of the water inside the membranes. This reveals that water moves at least an order of magnitude slower through the ion containing fuel cell membrane materials, consistent with a solution-diffusion model, while the water in the polyamide membranes moves faster, consistent with a pore-flow diffusion mechanism. These insights will be discussed in terms of a coupling of the water and polymer dynamics and design cues for high performance membrane materials.

  18. Corrosion Inhibition of the Galvanic Couple Copper-Carbon Steel in Reverse Osmosis Water

    Directory of Open Access Journals (Sweden)

    Irene Carrillo

    2011-01-01

    Full Text Available The purpose of this paper is to evaluate the electrochemical behaviour of corrosion inhibition of the copper-carbon steel galvanic couple (Cu-CS, exposed to reverse osmosis water (RO used for rinsing of heat exchangers for heavy duty machinery, during manufacture. Molybdate and nitrite salts were utilized to evaluate the inhibition behaviour under galvanic couple conditions. Cu-CS couple was used as working electrodes to measure open circuit potential (OCP, potentiodynamic polarization (PP, and electrochemical impedance spectroscopy (EIS. The surface conditions were characterized by scanning electron microscopy (SEM and electron dispersive X-ray spectroscopy (EDS. The most effective concentration ratio between molybdate and nitrite corrosion inhibitors was determined. The morphological study indicated molybdate deposition on the anodic sites of the galvanic couple. The design of molybdate-based corrosion inhibitor developed in the present work should be applied to control galvanic corrosion of the Cu-CS couple during cleaning in the manufacture of heat exchangers.

  19. An investigation of desalination by nanofiltration, reverse osmosis and integrated (hybrid NF/RO) membranes employed in brackish water treatment

    OpenAIRE

    Talaeipour, M.; J.Nouri; Hassani, A. H.; A. H. Mahvi

    2017-01-01

    Background As an appropriate tool, membrane process is used for desalination of brackish water, in the production of drinking water. The present study aims to investigate desalination processes of brackish water of Qom Province in Iran. Methods This study was carried out at the central laboratory of Water and Wastewater Company of the studied area. To this aim, membrane processes, including nanofiltration (NF) and reverse osmosis (RO), separately and also their hybrid process were applied. Mo...

  20. Effect of water temperature on biofouling development in reverse osmosis membrane systems

    KAUST Repository

    Farhat, Nadia

    2016-07-14

    Understanding the factors that determine the spatial and temporal biofilm development is a key to formulate effective control strategies in reverse osmosis membrane systems for desalination and wastewater reuse. In this study, biofilm development was investigated at different water temperatures (10, 20, and 30 °C) inside a membrane fouling simulator (MFS) flow cell. The MFS studies were done at the same crossflow velocity with the same type of membrane and spacer materials, and the same feed water type and nutrient concentration, differing only in water temperature. Spatially resolved biofilm parameters such as oxygen decrease rate, biovolume, biofilm spatial distribution, thickness and composition were measured using in-situ imaging techniques. Pressure drop (PD) increase in time was used as a benchmark as to when to stop the experiments. Biofilm measurements were performed daily, and experiments were stopped once the average PD increased to 40 mbar/cm. The results of the biofouling study showed that with increasing feed water temperature (i) the biofilm activity developed faster, (ii) the pressure drop increased faster, while (iii) the biofilm thickness decreased. At an average pressure drop increase of 40 mbar/cm over the MFS for the different feed water temperatures, different biofilm activities, structures, and quantities were found, indicating that diagnosis of biofouling of membranes operated at different or varying (seasonal) feed water temperatures may be challenging. Membrane installations with a high temperature feed water are more susceptible to biofouling than installations fed with low temperature feed water.

  1. Sanitization of an automatic reverse-osmosis watering system: removal of a clinically significant biofilm.

    Science.gov (United States)

    Molk, Denise M; Karr-May, Charlene L; Trang, Elaine D; Sanders, George E

    2013-03-01

    During environmental monitoring of our institution's rodent watering systems, one vivarium was found to have high bacterial loads in the reverse-osmosis (RO) automatic water system. These findings prompted evaluation of the entire RO water production and distribution system. Investigation revealed insufficient rack and RO system sanitization, leading to heavy biofilm accumulation within the system. Approximately 2 wk after discovery in the water system, one of the bacterial organisms isolated in the water supply, Sphingomonas paucimobilis, was isolated from a peritoneal abscess of a severely immunodeficient B6. Cg-Slc11a1(r) Rag1(tm1Mom)/Cwi mouse housed in the same vivarium, suggesting that rodents drinking from this system were being exposed randomly to fragments of biofilm. Plans were developed to sanitize the entire system. Hypercholorination was used first, followed by treatment with a combination of peracetic acid and hydrogen peroxide. Between system sanitizations, a low-level chlorine infusion was added to the system as a biocide. Heterotrophic plate counts and bacterial isolation were performed on water samples obtained before and after sanitization procedures. We here discuss the process of identifying and correcting this important water-quality issue.

  2. Integrating tunable anion exchange with reverse osmosis for enhanced recovery during inland brackish water desalination.

    Science.gov (United States)

    Smith, Ryan C; SenGupta, Arup K

    2015-05-05

    For inland brackish water desalination by reverse osmosis or RO, concentrate or reject disposal poses a major challenge. However, enhanced recovery and consequent reduction in the reject volume using RO processes is limited by the solubility of ions present in the feedwater. One of the most common and stubborn precipitate formed during desalination is calcium sulfate. Reducing or eliminating the presence of sulfate would allow the process to operate at higher recoveries without threat to membrane scaling. In this research, this goal is accomplished by using an appropriate mixture of self-regenerating anion exchange resins that selectively remove and replace sulfate by chloride prior to the RO unit. Most importantly, the mixed bed of anion exchange resins is self-regenerated with the reject brine from the RO process, thus requiring no addition of external chemicals. The current work demonstrates the reversibility of the hybrid ion exchange and RO (HIX-RO) process with 80% recovery for a brackish water composition representative of groundwater in San Joaquin Valley in California containing approximately 5200 mg/L of total dissolved solids or TDS. Consequently, the reject volume can be reduced by 50% without the threat of sulfate scaling and use of antiscaling chemicals can be eliminated altogether. By appropriately designing or tuning the mixed bed of anion exchange resins, the process can be extended to nearly any composition of brackish water for enhanced recovery and consequent reduction in the reject volume.

  3. Data on daily fluoride intake based on drinking water consumption prepared by household desalinators working by reverse osmosis process.

    Science.gov (United States)

    Karbasdehi, Vahid Noroozi; Dobaradaran, Sina; Esmaili, Abdolhamid; Mirahmadi, Roghayeh; Ghasemi, Fatemeh Faraji; Keshtkar, Mozhgan

    2016-09-01

    In this data article, we evaluated the daily fluoride contents in 20 household desalinators working by reverse osmosis (RO) process in Bushehr, Iran. The concentration levels of fluoride in inlet and outlet waters were determined by the standard SPADNS method using a spectrophotometer (M501 Single Beam Scanning UV/VIS, UK). The fluoride content in outlet waters were compared with EPA and WHO guidelines for drinking water.

  4. Use of water processed by reverse osmosis For vapor generation in tobacco industry

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Klimeck Gouvea

    2012-06-01

    Full Text Available This article presents a study due to the technical use of reverse osmosis to treat the boiler water for steam generation in a plant of tobacco processing in Santa Catarina, Brazil. The monitoring was conducted between the years 2006 to 2008, presenting the results concerning the improvement of water quality with emphasis on environmental and financial gains. Water quality can be observed by the reduction of 90% in silica content and 100% hardness, leading to a reduction of incrustation and corrosion of the system. Moreover, a reduction in the discharges water from the boiler volume reduced the water consumption by approximately 6,000 m3/year and also the consumption of chemicals used in wastewater treatment plant, with a reduction of 32.76 m3/day of effluents to treatment. The reducing of energy with natural gas for water heating replacement was almost 900,000 m3/year (19.45%, because of increased in heat exchange efficiency. The reducing in the CO2 emissions was in order of 1215,65 t/year. Finally, based on the achieved results obtained, can be possible to assume a reducing costs of production as a whole.

  5. Reverse osmosis, the solution for producing steam from highly saline water; Osmosis inversa, la solucion para la produccion de vapor con aguas de alta salinidad

    Energy Technology Data Exchange (ETDEWEB)

    Pujadas, A.

    2003-07-01

    Based on an exhaustive description of a particular example, the costs of installing an implementing various water treatment solutions for feeding a steam boiler are examined. When the characteristics of the water available indicate that it has a high saline content, i is possible to demonstrate the enormous technical, economic and environmental advantages of reducing its saline level by a system of reverse osmosis compared to the classical ion exchange resins. A list is given of the features to be taken into account in defining the equipment involved in treating the water for feeding steam boilers. (Author)

  6. Membrane Fouling and Chemical Cleaning in Three Full-Scale Reverse Osmosis Plants Producing Demineralized Water

    Directory of Open Access Journals (Sweden)

    Florian Beyer

    2017-01-01

    Full Text Available Membrane fouling and cleaning were studied in three reverse osmosis (RO plants. Feed water was secondary wastewater effluent, river water, and surface water. Membrane autopsies were used for fouling characterization. Fouling layer measurements included total organic carbon (TOC, adenosine triphosphate, polysaccharides, proteins, and heterotrophic plate counts. In all locations, membrane and spacer fouling was (bioorganic. Plant chemical cleaning efficiencies were evaluated from full-scale operational data and cleaning trials in a laboratory setup. Standard cleaning procedures were compared to two cleaning procedures specifically adapted to treat (bioorganic fouling using commercial blend cleaners (mixtures of active substances. The three RO plants were impacted by irreversible foulants causing permanently decreased performance in normalized pressure drop and water permeability even after thorough chemical cleaning. The standard plant and adapted cleaning procedures reduced the TOC by 45% on average, with a maximum of ~80%. In general, around 20% higher biomass removal could be achieved with adapted procedure I compared to adapted procedure II. TOC measurements and SEM showed that none of cleaning procedures applied could remove foulants completely from the membrane elements. This study underlines the need for novel cleaning approaches targeting resistant foulants, as none of the procedures applied resulted in highly effective membrane regeneration.

  7. Comparison of tertiary treatment by nanofiltration and reverse osmosis for water reuse in denim textile industry.

    Science.gov (United States)

    Ben Amar, Nihel; Kechaou, Noura; Palmeri, John; Deratani, André; Sghaier, Ali

    2009-10-15

    The wastewaters resulting from different baths of a dyeing factory specialized in denim fabric are collected and treated by an activated sludge plant. This study investigated the coupling of activated sludge treatment with either nanofiltration (NF) or reverse osmosis (RO) to recycle water and reuse it in the process. We first conducted NF experiments with a HL membrane in different configurations: dead end and cross-flow for flat sheets and also in spiral wound form. Results on water permeation and salt rejection show that performances are configuration dependent. Then, for the study of the NF/RO textile wastewater treatment, experiments were conducted with spiral wound membranes in order to be closest to the industrial configuration. After analyzing the removal efficiencies of suspended solids and chemical oxygen demand (COD) of the treatment plant, we conducted NF experiments using an HL2514TF spiral wound membrane preceded by ultrafiltration (UF) treatment. We used as well an RO membrane (AG2514TF) to compare performances in water yield and quality for the same pumping costs. The results show that NF allows higher yield, while respecting the Tunisian standard of water reuse (CODwater in the process.

  8. Contaminants of emerging concern in reverse osmosis brine concentrate from indirect/direct water reuse applications.

    Science.gov (United States)

    Romeyn, Travis R; Harijanto, Wesley; Sandoval, Sofia; Delagah, Saied; Sharbatmaleki, Mohamadali

    2016-01-01

    Water shortage is becoming more common due to droughts and global population increases resulting in the increasing popularity of water reuse to create new water sources. Reverse osmosis (RO) membrane systems are popular in these applications since they can produce drinking water quality effluent. Unfortunately, RO systems have the drawback of generating concentrate streams that contain contaminants rejected by the membrane including chemicals of emerging concern (CECs). CECs are chemicals such as hormones, steroids, pesticides, pharmaceuticals, and personal care products that are used for their intended purpose and then released into wastewater. CECs are believed to be detrimental to aquatic wildlife health and pose an unknown human health risk. This research gathered the existing knowledge on CEC presence in concentrate, available proven concentrate treatment methods, their CEC removal abilities, and current CEC regulations. It was found that 127 CECs have been measured in RO concentrate with 100 being detected at least once. The most potent treatment process available is UV/H2O2 as it offers the highest removal rates for the widest range of chemicals. The less expensive process of ozone/biologically activated carbon offers slightly lower removal abilities. This comprehensive report will provide the groundwork for better understanding, regulating and treating concentrate stream CECs.

  9. Rejection of Emerging Organic Contaminants by Nanofiltration and Reverse Osmosis Membranes: Effects of Fouling, Modelling and Water Reuse

    OpenAIRE

    Yangali Quintanilla, V.

    2010-01-01

    The book contains a description of the presence of micropollutants (medicines, hormones, pesticides) in surface water and shows that conventional water treatment poorly removes micropollutants. Nanofiltration and reverse osmosis are more appropriate technologies; however removals can vary depending on the properties of compounds and types of membranes. Thus, quantification of removals is studied by means of multivariate data analysis techniques and more understanding of the separation of micr...

  10. Removal of arsenic using reverse osmosis

    OpenAIRE

    Fauskrud, Marie

    2013-01-01

    Master's thesis in Water and Enviromental Technology Arsenic is an element that naturally occurs in rocks and sediments. In some areas, arsenic is released to ground water and can contaminate drinking water sources. Since arsenic is toxic in high doses and a carcinogen, the World Health Organisation (WHO) recommends arsenic levels lower than 10 μg/L in drinking water. This thesis describes the removal of arsenic in a reverse osmosis system. Arsenic is usually present in water in two oxi...

  11. Membrane distillation for wastewater reverse osmosis concentrate treatment with water reuse potential

    KAUST Repository

    Naidu, Gayathri

    2016-11-29

    Membrane distillation (MD) was evaluated as a treatment option of wastewater reverse osmosis concentrate (WWROC) discharged from wastewater reclamation plants (WRPs). A direct contact MD (DCMD), at obtaining 85% water recovery of WWROC showed only 13–15% flux decline and produced good quality permeate (10–15 µS/cm, 99% ion rejection) at moderate feed temperature of 55 °C. Prevalent calcium carbonate (CaCO3) deposition on the MD membrane occurred in treating WWROC at elevated concentrations. The combination of low salinity and loose CaCO3 adhesion on the membrane did not significantly contribute to DCMD flux decline. Meanwhile, high organic content in WWROC (58–60 mg/L) resulted in a significant membrane hydrophobicity reduction (70% lower water contact angle than virgin membrane) attributed to low molecular weight organic adhesion onto the MD membrane. Granular activated carbon (GAC) pretreatment helped in reducing organic contents of WWROC by 46–50%, and adsorbed a range of hydrophobic and hydrophilic micropollutants. This ensured high quality water production by MD (micropollutants-free) and enhanced its reuse potential. The MD concentrated WWROC was suitable for selective ion precipitation, promising a near zero liquid discharge in WRPs.

  12. Subsurface intakes for seawater reverse osmosis facilities: Capacity limitation, water quality improvement, and economics

    KAUST Repository

    Missimer, Thomas M.

    2013-08-01

    The use of subsurface intake systems for seawater reverse osmosis (SWRO) desalination plants significantly improves raw water quality, reduces chemical usage and environmental impacts, decreases the carbon footprint, and reduces cost of treated water to consumers. These intakes include wells (vertical, angle, and radial type) and galleries, which can be located either on the beach or in the seabed. Subsurface intakes act both as intakes and as part of the pretreatment system by providing filtration and active biological treatment of the raw seawater. Recent investigations of the improvement in water quality made by subsurface intakes show lowering of the silt density index by 75 to 90%, removal of nearly all algae, removal of over 90% of bacteria, reduction in the concentrations of TOC and DOC, and virtual elimination of biopolymers and polysaccharides that cause organic biofouling of membranes. Economic analyses show that overall SWRO operating costs can be reduced by 5 to 30% by using subsurface intake systems. Although capital costs can be slightly to significantly higher compared to open-ocean intake system costs, a preliminary life-cycle cost analysis shows significant cost saving over operating periods of 10 to 30. years. © 2013 Elsevier B.V.

  13. CAPSULE REPORT: REVERSE OSMOSIS PROCESS

    Science.gov (United States)

    A failure analysis has been completed for the reverse osmosis (RO) process. The focus was on process failures that result in releases of liquids and vapors to the environment. The report includes the following: 1) A description of RO and coverage of the principles behind the proc...

  14. A comparative study of boron and arsenic (III) rejection from brackish water by reverse osmosis membranes

    KAUST Repository

    Teychene, Benoît

    2013-02-01

    This study aims to compare at lab-scale the rejection efficiency of several reverse osmosis membranes (RO) toward arsenic (III) and boron during the filtration of a synthetic brackish water. The effect of pH and operating conditions on the rejection of each RO membrane was studied. Two types of membrane were investigated: "brackish water" and "sea water" membranes. Our results showed that the metalloid rejection depends on the membrane type, pH and transmembrane pressure applied. Increasing pH above the dissociation constant (pKa) of each specie improves significantly the metalloid rejection by RO membranes, whatever the membrane type. Moreover, at identical operating conditions (pH, transmembrane pressure), results showed that the brackish water membranes have a higher water flux and exhibit lower metalloid rejection. The highest As(III) rejection value for the tested brackish water membranes was 99% obtained at pH = 9.6 and 40 bars, whereas it was found that the sea water RO membranes could highly reject As(III), more than 99%, even at low pH and low pressure (pH = 7.6 and 24 bars).Regarding Boron rejection, similar conclusions could be drawn. The sea water RO membranes exert higher removal, with a high rejection value above 96% over the tested conditions. More generally, this study showed that, whatever the operating conditions or the tested membranes, the boron and As(III) permeate concentrations are below the WHO guidelines. In addition, new data about the boron and arsenic permeability of each tested RO membrane was brought thanks to a theoretical calculation. © 2012 Elsevier B.V.

  15. Effect of water temperature on biofouling development in reverse osmosis membrane systems.

    Science.gov (United States)

    Farhat, N M; Vrouwenvelder, J S; Van Loosdrecht, M C M; Bucs, Sz S; Staal, M

    2016-10-15

    Understanding the factors that determine the spatial and temporal biofilm development is a key to formulate effective control strategies in reverse osmosis membrane systems for desalination and wastewater reuse. In this study, biofilm development was investigated at different water temperatures (10, 20, and 30 °C) inside a membrane fouling simulator (MFS) flow cell. The MFS studies were done at the same crossflow velocity with the same type of membrane and spacer materials, and the same feed water type and nutrient concentration, differing only in water temperature. Spatially resolved biofilm parameters such as oxygen decrease rate, biovolume, biofilm spatial distribution, thickness and composition were measured using in-situ imaging techniques. Pressure drop (PD) increase in time was used as a benchmark as to when to stop the experiments. Biofilm measurements were performed daily, and experiments were stopped once the average PD increased to 40 mbar/cm. The results of the biofouling study showed that with increasing feed water temperature (i) the biofilm activity developed faster, (ii) the pressure drop increased faster, while (iii) the biofilm thickness decreased. At an average pressure drop increase of 40 mbar/cm over the MFS for the different feed water temperatures, different biofilm activities, structures, and quantities were found, indicating that diagnosis of biofouling of membranes operated at different or varying (seasonal) feed water temperatures may be challenging. Membrane installations with a high temperature feed water are more susceptible to biofouling than installations fed with low temperature feed water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Removal of fouling species from brackish water reverse osmosis reject stream.

    Science.gov (United States)

    Ayoub, G M; Korban, L; Al-Hindi, M; Zayyat, R

    2018-03-01

    Brine disposal from reverse osmosis (RO) systems remains a major challenge for the desalination industry especially in inland areas where discharge options are very limited. Solutions will entail the introduction of economic treatment processes that will alleviate the brine's negative impact on the environment and reduce its discharge volume. Such processes could act as an intermediary treatment process for the recycling of the brine through an additional RO stage which, for brackish water (BW) desalination, could lead to saving valuable water while reducing the amount of brine discharge. In this context, the study at hand attempts to evaluate the effectiveness of a one-step chemical process for the treatment of BWRO brine. This study seeks to determine optimal operating conditions relative to type, ratio, and dosage of alkalizing chemicals, pH and temperature, for substantially reducing the concentrations of scaling parameters such as calcium, magnesium, silica, and strontium. The results indicate that precipitation softening at pH = 11.5 using combined chemical dosages of NaOH and Na 2 CO 3 in a ratio of 2:1 leads to substantial removal of calcium and magnesium (>95%) and moderately high removal of strontium and silica (>71%).

  17. Rejection of pharmaceuticals in nanofiltration and reverse osmosis membrane drinking water treatment.

    Science.gov (United States)

    Radjenović, J; Petrović, M; Ventura, F; Barceló, D

    2008-08-01

    This paper investigates the removal of a broad range of pharmaceuticals during nanofiltration (NF) and reverse osmosis (RO) applied in a full-scale drinking water treatment plant (DWTP) using groundwater. Pharmaceutical residues detected in groundwater used as feed water in all five sampling campaigns were analgesics and anti-inflammatory drugs such as ketoprofen, diclofenac, acetaminophen and propyphenazone, beta-blockers sotalol and metoprolol, an antiepileptic drug carbamazepine, the antibiotic sulfamethoxazole, a lipid regulator gemfibrozil and a diuretic hydrochlorothiazide. The highest concentrations in groundwater were recorded for hydrochlorothiazide (58.6-2548ngL(-1)), ketoprofen (85%). Deteriorations in retentions on NF and RO membranes were observed for acetaminophen (44.8-73 %), gemfibrozil (50-70 %) and mefenamic acid (30-50%). Furthermore, since several pharmaceutical residues were detected in the brine stream of NF and RO processes at concentrations of several hundreds nanogram per litre, its disposal to a near-by river can represent a possible risk implication of this type of treatment.

  18. Nanofiltration vs. reverse osmosis for the removal of emerging organic contaminants in water reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2011-01-01

    Reverse osmosis (RO) in existing water reuse facilities is a water industry standard. However, that approach may be questioned taking into consideration that "tight" NF can be equal or "better" than RO. NF can achieve the same removals of RO membranes when dealing with emerging organic contaminants (pharmaceuticals, pesticides, endocrine disruptors and others). Experiments using 18 emerging contaminants were performed using membranes NF200 and NF90 at bench-scale units, and for a more complete study, results of NF and RO pilot and fullscale experiments where compared to our experimental results. The removal results showed that NF can remove many emerging contaminants. The average removal by tight NF was 82% for neutral contaminants and 97% for ionic contaminants. The average removal by RO was 85% for neutral contaminants and 99% for ionic contaminants. Aquifer recharge and recovery (ARR) followed by NF can effectively remove emerging contaminants with removals over 90% when loose NF membranes are used. © 2011 2011 Desalination Publications. All rights reserved.

  19. Reverse osmosis integrity monitoring in water reuse: The challenge to verify virus removal - A review.

    Science.gov (United States)

    Pype, Marie-Laure; Lawrence, Michael G; Keller, Jurg; Gernjak, Wolfgang

    2016-07-01

    A reverse osmosis (RO) process is often included in the treatment train to produce high quality reuse water from treated effluent for potable purposes because of its high removal efficiency for salinity and many inorganic and organic contaminants, and importantly, it also provides an excellent barrier for pathogens. In order to ensure the continued protection of public health from pathogen contamination, monitoring RO process integrity is necessary. Due to their small sizes, viruses are the most difficult class of pathogens to be removed in physical separation processes and therefore often considered the most challenging pathogen to monitor. To-date, there is a gap between the current log credit assigned to this process (determined by integrity testing approved by regulators) and its actual log removal capability as proven in a variety of laboratory and pilot studies. Hence, there is a challenge to establish a methodology that more closely links to the theoretical performance. In this review, after introducing the notion of risk management in water reuse, we provide an overview of existing and potentially new RO integrity monitoring techniques, highlight their strengths and drawbacks, and debate their applicability to full-scale treatment plants, which open to future research opportunities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Preparation and water desalination properties of POSS-polyamide nanocomposite reverse osmosis membranes

    KAUST Repository

    Duan, Jintang

    2015-01-01

    The application of nanotechnology to thin-film nanocomposites (TFN) is a new route to enhance membrane performance in water desalination. Here, the potential of polyhedral oligomeric silsesquioxane (POSS) as the nanofiller in polyamide (PA) reverse osmosis membranes was systematically investigated. Four POSS materials (P-8Phenyl, P-8NH3Cl, P-8NH2 and P-1NH2) were introduced into the selective layer by physical blending or chemical fixation during standard interfacial polymerization. Water flux and NaCl rejection were measured with 2000ppm NaCl solution under 15.5bar pressure, and SEM and TEM images of membrane selective layers were obtained. Membranes prepared without POSS showed water flux of 20.0±0.5L/m2·h and salt rejection of 98.0±0.2%. TFN membranes prepared with 0.4% (w/v) P-8Phenyl in the organic phase showed a 65% increase in water flux compared to the pristine PA membrane while maintaining high salt rejection. The selective layer of this membrane maintained the typical ridge-and-valley structure of aromatic PA. Results with P-8NH3Cl and P-8NH2 added to the organic phase were similar. TFN membranes prepared with monoamine P-1NH2 in the organic phase had poor water flux of 3.2L/m2·h, a smooth and more hydrophobic surface, and a much thicker (~400nm) selective layer. One of the four POSS compounds studied, P-8NH3Cl, is sufficiently soluble in water for incorporation into the selective layer via the aqueous phase. Membranes were prepared with P-8NH3Cl in the aqueous phase at varying reaction time, loading, and additive (triethylamine) concentration. With these parameters optimized, water flux increased to 35.4L/m2·h.

  1. Assessment of the extent of bacterial growth in reverse osmosis system for improving drinking water quality.

    Science.gov (United States)

    Park, Se-keun; Hu, Jiang Yong

    2010-01-01

    This study was carried out to assess reverse osmosis (RO) treatment efficacy of drinking water in terms of biological stability in the distribution system. Two flat-sheet RO membranes were used in this study. Experiments were designed to investigate the growth of biofilm and bulk phase bacteria for the RO-treated water flowing through a model distribution system under controlled conditions without disinfectants. RO membranes improved the water quality of drinking water in terms of inorganic, organic and bacterial contents. Organic matter including the fraction available for microbes was efficiently removed by the RO membranes tested. More than 99% of bacterial cells in the tap water was retained by the RO membranes, leaving water. In spite of the low nutrient contents and few cells in the RO permeates, monitoring of the model distribution systems receiving the RO permeates showed that remarkable biofilm accumulation and bulk cell growth occurred in the RO permeate water. In quasi-steady state, the total cell numbers in the biofilm and bulk water were of order 10(3) cells/cm(2) and 10(3) cells/mL, respectively, which were about 2 orders of magnitude lower than those grown in the tap water produced from conventional water treatment. The culturable heterotrophic bacteria constituted a significant part of the total cells (20.7-32.1% in biofilms and 21.3-46.3% in bulk waters). Biofilm maximum density and production rate were of the order 10(4) cells/cm(2) and 10(2) cells/cm(2)/day, respectively. The specific cell growth rate of bacteria in the biofilms was found to be much lower than those in the bulk waters (0.04-0.05 day(-1) versus 0.28-0.36 day(-1)). The overall specific cell growth rate which indicates the growth potential in the whole system was calculated as 0.07-0.08 day(-1), representing a doubling time of 9.1-10.1 days. These observations can be indicative of possibilities for bacterial growth in the RO permeate water with easily assimilable organic carbon

  2. DRINKING WATER FROM DESALINATION OF SEAWATER: OPTIMIZATION OF REVERSE OSMOSIS SYSTEM OPERATING PARAMETERS

    Directory of Open Access Journals (Sweden)

    MARWAN M. SHAMEL

    2006-12-01

    Full Text Available This paper reports on the use of pilot scale membrane separation system coupled with another pilot scale plate heat exchanger to investigate the possibilities of sweetening seawater from Telok Kalong Beach, Terengganu, Malaysia. Reverse osmosis (RO membrane of a surface area of 0.5 m2 was used during the experimental runs. Experiments were conducted at different transmembrane pressures (TMP ranged from 40 to 55 bars, operation temperature ranged from 35 to 45oC, feed concentration (TDS ranged from 34900 to 52500 ppm and cross flow velocities ranged from 1.4 to 2.1 m/s. The result show that the flux values increased linearly with TMP as well as sodium ion rejection. Permeate flux values increased proportionally with the temperature and the later effect was more significant at high pressures. The temperature changing has also influenced the rejection of sodium ion. The minerals content especially NaCl and total dissolved solid (TDS in the drinking water produced in this research are conforming to the standards of World Health Organization (WHO.

  3. Removal of bisphenol A (BPA) from water by various nanofiltration (NF) and reverse osmosis (RO) membranes.

    Science.gov (United States)

    Yüksel, Suna; Kabay, Nalan; Yüksel, Mithat

    2013-12-15

    The removal of an endocrine disrupting compound, bisphenol A (BPA), from model solutions by selected nanofiltration (NF) and reverse osmosis (RO) membranes was studied. The commercially available membranes NF 90, NF 270, XLE BWRO, BW 30 (Dow FilmTech), CE BWRO and AD SWRO (GE Osmonics) were used to compare their performances for BPA removal. The water permeability coefficients, rejection of BPA and permeate flux values were calculated for all membranes used. No significant changes in their BPA removal were observed for all tight polyamide based NF and RO membranes tested except for loose NF 270 membrane. The polyamide based membranes exhibited much better performance than cellulose acetate membrane for BPA removal. Almost a complete rejection (≥ 98%) for BPA was obtained with three polyamide based RO membranes (BW 30, XLE BWRO and AD SWRO). But cellulose acetate based CE BWRO membrane offered a low and variable (10-40%) rejection for BPA. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. State of the art and review on the treatment technologies of water reverse osmosis concentrates.

    Science.gov (United States)

    Pérez-González, A; Urtiaga, A M; Ibáñez, R; Ortiz, I

    2012-02-01

    The growing demand for fresh water is partially satisfied by desalination plants that increasingly use membrane technologies and among them reverse osmosis to produce purified water. Operating with water recoveries from 35% to 85% RO plants generate huge volumes of concentrates containing all the retained compounds that are commonly discharged to water bodies and constitute a potentially serious threat to marine ecosystems; therefore there is an urgent need for environmentally friendly management options of RO brines. This paper gives an overview on the potential treatments to overcome the environmental problems associated to the direct discharge of RO concentrates. The treatment options have been classified according to the source of RO concentrates and the maturity of the technologies. For the sake of clarity three different sources of RO concentrates are differentiated i) desalination plants, ii) tertiary processes in WWTP, and iii) mining industries. Starting with traditional treatments such as evaporation and crystallization other technologies that have emerged in last years to reduce the volume of the concentrate before disposal and with the objective of achieving zero liquid discharge and recovery of valuable compounds from these effluents are also reviewed. Most of these emerging technologies have been developed at laboratory or pilot plant scale (see Table 1). With regard to RO concentrates from WWTP, the manuscript addresses recent studies that are mainly focused on reducing the organic pollutant load through the application of innovative advanced oxidation technologies. Finally, works that report the treatment of RO concentrates from industrial sources are analyzed as well. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Using microbial desalination cells to reduce water salinity prior to reverse osmosis

    KAUST Repository

    Mehanna, Maha

    2010-01-01

    A microbial desalination cell (MDC) is a new method to reduce the salinity of one solution while generating electrical power from organic matter and bacteria in another (anode) solution. Substantial reductions in the salinity can require much larger volumes of the anode solution than the saline water, but any reduction of salinity will benefit the energy efficiency of a downstream reverse osmosis (RO) desalination system. We investigated here the use of an MDC as an RO pre-treatment method using a new type of air-cathode MDC containing three equally sized chambers. A single cycle of operation using a 1 g L -1 acetate solution reduced the conductivity of salt water (5 g L-1 NaCl) by 43 ± 6%, and produced a maximum power density of 480 mW m-2 with a coulombic efficiency of 68 ± 11%. A higher concentration of acetate (2 g L-1) reduced solution conductivity by 60 ± 7%, and a higher salt concentration (20 g L-1 NaCl) reduced solution conductivity by 50 ± 7%. The use of membranes with increased ion exchange capacities further decreased the solution conductivity by 63 ± 2% (20 g L-1 NaCl). These results demonstrate substantial (43-67%) desalination of water is possible using equal volumes of anode solution and salt water. These results show that MDC treatment could be used to substantially reduce salt concentrations and thus energy demands for downstream RO processing, while at the same time producing electrical power. © 2010 The Royal Society of Chemistry.

  6. Osmotic versus conventional membrane bioreactors integrated with reverse osmosis for water reuse: Biological stability, membrane fouling, and contaminant removal.

    Science.gov (United States)

    Luo, Wenhai; Phan, Hop V; Xie, Ming; Hai, Faisal I; Price, William E; Elimelech, Menachem; Nghiem, Long D

    2017-02-01

    This study systematically compares the performance of osmotic membrane bioreactor - reverse osmosis (OMBR-RO) and conventional membrane bioreactor - reverse osmosis (MBR-RO) for advanced wastewater treatment and water reuse. Both systems achieved effective removal of bulk organic matter and nutrients, and almost complete removal of all 31 trace organic contaminants investigated. They both could produce high quality water suitable for recycling applications. During OMBR-RO operation, salinity build-up in the bioreactor reduced the water flux and negatively impacted the system biological treatment by altering biomass characteristics and microbial community structure. In addition, the elevated salinity also increased soluble microbial products and extracellular polymeric substances in the mixed liquor, which induced fouling of the forward osmosis (FO) membrane. Nevertheless, microbial analysis indicated that salinity stress resulted in the development of halotolerant bacteria, consequently sustaining biodegradation in the OMBR system. By contrast, biological performance was relatively stable throughout conventional MBR-RO operation. Compared to conventional MBR-RO, the FO process effectively prevented foulants from permeating into the draw solution, thereby significantly reducing fouling of the downstream RO membrane in OMBR-RO operation. Accumulation of organic matter, including humic- and protein-like substances, as well as inorganic salts in the MBR effluent resulted in severe RO membrane fouling in conventional MBR-RO operation. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  7. Selective removal of arsenic and monovalent ions from brackish water reverse osmosis concentrate.

    Science.gov (United States)

    Xu, Pei; Capito, Marissa; Cath, Tzahi Y

    2013-09-15

    Concentrate disposal and management is a considerable challenge for the implementation of desalination technologies, especially for inland applications where concentrate disposal options are limited. This study has focused on selective removal of arsenic and monovalent ions from brackish groundwater reverse osmosis (RO) concentrate for beneficial use and safe environmental disposal using in situ and pre-formed hydrous ferric oxides/hydroxides adsorption, and electrodialysis (ED) with monovalent permselective membranes. Coagulation with ferric salts is highly efficient at removing arsenic from RO concentrate to meet a drinking water standard of 10 μg/L. The chemical demand for ferric chloride however is much lower than ferric sulfate as coagulant. An alternative method using ferric sludge from surface water treatment plant is demonstrated as an efficient adsorbent to remove arsenic from RO concentrate, providing a promising low cost, "waste treat waste" approach. The monovalent permselective anion exchange membranes exhibit high selectivity in removing monovalent anions over di- and multi-valent anions. The transport of sulfate and phosphate through the anion exchange membranes was negligible over a broad range of electrical current density. However, the transport of divalent cations such as calcium and magnesium increases through monovalent permselective cation exchange membranes with increasing current density. Higher overall salt concentration reduction is achieved around limiting current density while higher normalized salt removal rate in terms of mass of salt per membrane area and applied energy is attained at lower current density because the energy unitization efficiency decreases at higher current density. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Removal of haloacetic acids from swimming pool water by reverse osmosis and nanofiltration.

    Science.gov (United States)

    Yang, Linyan; She, Qianhong; Wan, Man Pun; Wang, Rong; Chang, Victor W-C; Tang, Chuyang Y

    2017-06-01

    Recent studies report high concentrations of haloacetic acids (HAAs), a prevalent class of toxic disinfection by-products, in swimming pool water (SPW). We investigated the removal of 9 HAAs by four commercial reverse osmosis (RO) and nanofiltration (NF) membranes. Under typical SPW conditions (pH 7.5 and 50 mM ionic strength), HAA rejections were >60% for NF270 with molecular weight cut-off (MWCO) equal to 266 Da and equal or higher than 90% for XLE, NF90 and SB50 with MWCOs of 96, 118 and 152 Da, respectively, as a result of the combined effects of size exclusion and charge repulsion. We further included 7 neutral hydrophilic surrogates as molecular probes to resolve the rejection mechanisms. In the absence of strong electrostatic interaction (e.g., pH 3.5), the rejection data of HAAs and surrogates by various membranes fall onto an identical size-exclusion (SE) curve when plotted against the relative-size parameter, i.e., the ratio of molecular radius over membrane pore radius. The independence of this SE curve on molecular structures and membrane properties reveals that the relative-size parameter is a more fundamental SE descriptor compared to molecular weight. An effective molecular size with the Stokes radius accounting for size exclusion and the Debye length accounting for electrostatic interaction was further used to evaluate the rejection. The current study provides valuable insights on the rejection of trace contaminants by RO/NF membranes. Copyright © 2017. Published by Elsevier Ltd.

  9. Dialysis water treated by reverse osmosis decreases the levels of C-reactive protein in uremic patients

    Directory of Open Access Journals (Sweden)

    F.S. Thomé

    2005-05-01

    Full Text Available Atherosclerosis is a major complication of chronic renal failure. Microinflammation is involved in atherogenesis and is associated with uremia and dialysis. The role of dialysate water contamination in inducing inflammation has been debated. Our aim was to study inflammatory markers in patients on chronic dialysis, before and 3 to 6 months after switching the water purification system from deionization to reverse osmosis. Patients had demographic, clinical and nutritional information collected and blood drawn for determination of albumin, ferritin, C-reactive protein (CRP, interleukin-6, and tumor necrosis factor-alpha in both situations. Acceptable levels of water purity were less than 200 colony-forming units of bacteria and less than 1 ng/ml of endotoxin. Sixteen patients died. They had higher median CRP (26.6 vs 11.2 mg/dl, P = 0.007 and lower median albumin levels (3.1 vs 3.9 g/l, P < 0.05 compared to the 31 survivors. Eight patients were excluded because of obvious inflammatory conditions. From the 23 remaining patients (mean age ± SD: 51.3 ± 13.9 years, 18 had a decrease in CRP after the water treatment system was changed. Overall, median CRP was lower with reverse osmosis than with deionization (13.2 vs 4.5 mg/l, P = 0.022, N = 23. There was no difference in albumin, cytokines, subjective global evaluation, or clinical and biochemical parameters. In conclusion, uremic patients presented a clinically significant reduction in CRP levels when dialysate water purification system switched from deionization to reverse osmosis. It is possible that better water treatments induce less inflammation and eventually less atherosclerosis in hemodialysis patients.

  10. Technical-Economic Analysis of Photovoltaik Reverse Osmosis Planning for Fulfillment of Fresh Water System on Ro-Pax Ship

    Directory of Open Access Journals (Sweden)

    Edi Jadmiko

    2017-09-01

    Full Text Available The need for fresh water in the world of industry is increasing with the rapid development of the global industry. The shipping industry is having a significant impact as part of a global industry concerning the sector of freshwater demand on ships. Freshwater supplies on ro-pax vessels are very important because they are the source of crew and passenger life when ships sail. Fulfillment of freshwater needs on a ro-pax vessel is made in a conventional system by filling clean water into a freshwater tank from the port. In this final project will be analyzed technical and economical on designing fresh water system using reverse osmosis system with solar panel as power supply and compare it with conventional system on ship KM. SABUK NUSANTARA 56. This Final Project includes installation design, size of fresh water tank, amount of cargo, investment cost and operational cost. The conclusion obtained in this final project is a reverse osmosis (RO system with solar panels as a very efficient power supply when applied to ro-pax ships such as ships KM SABUK NUSANTARA 56 because with this system the ship is able to produce their own fresh water, the size of the freshwater tank is smaller, for new shiploads can be increased. For the percentage of total cost of fresh water needs is dearer about 52 percent compared to conventional system and payload value increased 29.2 percent compared to conventional system.

  11. Reverse Osmosis Processing of Organic Model Compounds and Fermentation Broths

    Science.gov (United States)

    2006-04-01

    followed by RO treatment step for water recycling in electronic industry (Chen and Chen, 2004), meat processing industry (Bohdziewicz and Sroka, 2005...Membr. Sci. 255, 117–124. Todtheide, V., Laufenberg, G., Kunz, B., 1997. Waste water treatment using reverse osmosis: real osmotic pressure and chemical...A., Inanc, B., 2002. Fouling of reverse osmosis and nanofiltration membranes by dairy industry effluents. Water Sci. Technol. 45 (12), 355–360

  12. Efficiently Combining Water Reuse and Desalination through Forward Osmosis—Reverse Osmosis (FO-RO Hybrids: A Critical Review

    Directory of Open Access Journals (Sweden)

    Gaetan Blandin

    2016-07-01

    Full Text Available Forward osmosis (FO is a promising membrane technology to combine seawater desalination and water reuse. More specifically, in a FO-reverse osmosis (RO hybrid process, high quality water recovered from the wastewater stream is used to dilute seawater before RO treatment. As such, lower desalination energy needs and/or water augmentation can be obtained while delivering safe water for direct potable reuse thanks to the double dense membrane barrier protection. Typically, FO-RO hybrid can be a credible alternative to new desalination facilities or to implementation of stand-alone water reuse schemes. However, apart from the societal (public perception of water reuse for potable application and water management challenges (proximity of wastewater and desalination plants, FO-RO hybrid has to overcome technical limitation such as low FO permeation flux to become economically attractive. Recent developments (i.e., improved FO membranes, use of pressure assisted osmosis, PAO demonstrated significant improvement in water flux. However, flux improvement is associated with drawbacks, such as increased fouling behaviour, lower rejection of trace organic compounds (TrOCs in PAO operation, and limitation in FO membrane mechanical resistance, which need to be better considered. To support successful implementation of FO-RO hybrid in the industry, further work is required regarding up-scaling to apprehend full-scale challenges in term of mass transfer limitation, pressure drop, fouling and cleaning strategies on a module scale. In addition, refined economics assessment is expected to integrate fouling and other maintenance costs/savings of the FO/PAO-RO hybrid systems, as well as cost savings from any treatment step avoided in the water recycling.

  13. Efficiently Combining Water Reuse and Desalination through Forward Osmosis—Reverse Osmosis (FO-RO) Hybrids: A Critical Review

    Science.gov (United States)

    Blandin, Gaetan; Verliefde, Arne R.D.; Comas, Joaquim; Rodriguez-Roda, Ignasi; Le-Clech, Pierre

    2016-01-01

    Forward osmosis (FO) is a promising membrane technology to combine seawater desalination and water reuse. More specifically, in a FO-reverse osmosis (RO) hybrid process, high quality water recovered from the wastewater stream is used to dilute seawater before RO treatment. As such, lower desalination energy needs and/or water augmentation can be obtained while delivering safe water for direct potable reuse thanks to the double dense membrane barrier protection. Typically, FO-RO hybrid can be a credible alternative to new desalination facilities or to implementation of stand-alone water reuse schemes. However, apart from the societal (public perception of water reuse for potable application) and water management challenges (proximity of wastewater and desalination plants), FO-RO hybrid has to overcome technical limitation such as low FO permeation flux to become economically attractive. Recent developments (i.e., improved FO membranes, use of pressure assisted osmosis, PAO) demonstrated significant improvement in water flux. However, flux improvement is associated with drawbacks, such as increased fouling behaviour, lower rejection of trace organic compounds (TrOCs) in PAO operation, and limitation in FO membrane mechanical resistance, which need to be better considered. To support successful implementation of FO-RO hybrid in the industry, further work is required regarding up-scaling to apprehend full-scale challenges in term of mass transfer limitation, pressure drop, fouling and cleaning strategies on a module scale. In addition, refined economics assessment is expected to integrate fouling and other maintenance costs/savings of the FO/PAO-RO hybrid systems, as well as cost savings from any treatment step avoided in the water recycling. PMID:27376337

  14. An investigation of desalination by nanofiltration, reverse osmosis and integrated (hybrid NF/RO) membranes employed in brackish water treatment

    National Research Council Canada - National Science Library

    M Talaeipour; J Nouri; A H Hassani; A H Mahvi

    2017-01-01

    ...), electric conductivity (EC), Na+1 and Cl−1 were also measured. Afterward, the rejection percent of each parameter was investigated and compared using nanofiltration and reverse osmosis separately and also by their hybrid...

  15. Hexavalent Chromium Removal from Model Water and Car Shock Absorber Factory Effluent by Nanofiltration and Reverse Osmosis Membrane.

    Science.gov (United States)

    Mnif, Amine; Bejaoui, Imen; Mouelhi, Meral; Hamrouni, Béchir

    2017-01-01

    Nanofiltration and reverse osmosis are investigated as a possible alternative to the conventional methods of Cr(VI) removal from model water and industrial effluent. The influences of feed concentration, water recovery, pH, and the coexisting anions were studied. The results have shown that retention rates of hexavalent chromium can reach 99.7% using nanofiltration membrane (NF-HL) and vary from 85 to 99.9% using reverse osmosis membrane (RO-SG) depending upon the composition of the solution and operating conditions. This work was also extended to investigate the separation of Cr(VI) from car shock absorber factory effluent. The use of these membranes is very promising for Cr(VI) water treatment and desalting industry effluent. Spiegler-Kedem model was applied to experimental results in the aim to determine phenomenological parameters, the reflection coefficient of the membrane (σ), and the solute permeability coefficient (Ps ). The convective and diffusive parts of the mass transfer were quantified with predominance of the diffusive contribution.

  16. Hexavalent Chromium Removal from Model Water and Car Shock Absorber Factory Effluent by Nanofiltration and Reverse Osmosis Membrane

    Directory of Open Access Journals (Sweden)

    Amine Mnif

    2017-01-01

    Full Text Available Nanofiltration and reverse osmosis are investigated as a possible alternative to the conventional methods of Cr(VI removal from model water and industrial effluent. The influences of feed concentration, water recovery, pH, and the coexisting anions were studied. The results have shown that retention rates of hexavalent chromium can reach 99.7% using nanofiltration membrane (NF-HL and vary from 85 to 99.9% using reverse osmosis membrane (RO-SG depending upon the composition of the solution and operating conditions. This work was also extended to investigate the separation of Cr(VI from car shock absorber factory effluent. The use of these membranes is very promising for Cr(VI water treatment and desalting industry effluent. Spiegler-Kedem model was applied to experimental results in the aim to determine phenomenological parameters, the reflection coefficient of the membrane (σ, and the solute permeability coefficient (Ps. The convective and diffusive parts of the mass transfer were quantified with predominance of the diffusive contribution.

  17. Hexavalent Chromium Removal from Model Water and Car Shock Absorber Factory Effluent by Nanofiltration and Reverse Osmosis Membrane

    Science.gov (United States)

    Bejaoui, Imen; Mouelhi, Meral; Hamrouni, Béchir

    2017-01-01

    Nanofiltration and reverse osmosis are investigated as a possible alternative to the conventional methods of Cr(VI) removal from model water and industrial effluent. The influences of feed concentration, water recovery, pH, and the coexisting anions were studied. The results have shown that retention rates of hexavalent chromium can reach 99.7% using nanofiltration membrane (NF-HL) and vary from 85 to 99.9% using reverse osmosis membrane (RO-SG) depending upon the composition of the solution and operating conditions. This work was also extended to investigate the separation of Cr(VI) from car shock absorber factory effluent. The use of these membranes is very promising for Cr(VI) water treatment and desalting industry effluent. Spiegler-Kedem model was applied to experimental results in the aim to determine phenomenological parameters, the reflection coefficient of the membrane (σ), and the solute permeability coefficient (Ps). The convective and diffusive parts of the mass transfer were quantified with predominance of the diffusive contribution. PMID:28819360

  18. Biofouling of reverse osmosis membranes used in river water purification for drinking purposes: analysis of microbial populations.

    Science.gov (United States)

    Chiellini, Carolina; Iannelli, Renato; Modeo, Letizia; Bianchi, Veronica; Petroni, Giulio

    2012-01-01

    Biofouling in water treatment processes represents one of the most frequent causes of plant performance decline. Investigation of clogged membranes (reverse osmosis membranes, microfiltration membranes and ultrafiltration membranes) is generally performed on fresh membranes. In the present study, a multidisciplinary autopsy of a reverse osmosis membrane (ROM) was conducted. The membrane, which was used in sulfate-rich river water purification for drinking purposes, had become inoperative after 6 months because of biofouling and was later stored for 18 months in dry conditions before analysis. SSU rRNA gene library construction, clone sequencing, T-RFLP, light microscope, and scanning electron microscope (SEM) observations were used to identify the microorganisms present on the membrane and possibly responsible for biofouling at the time of removal. The microorganisms were mainly represented by bacteria belonging to the phylum Actinobacteria and by a single protozoan species belonging to the Lobosea group. The microbiological analysis was interpreted in the context of the treatment plant operations to hypothesize as to the possible mechanisms used by microorganisms to enter the plant and colonize the ROM surface.

  19. Biological denitrification of reverse osmosis brine concentrates: I. Batch reactor and chemostat studies

    National Research Council Canada - National Science Library

    Ersever, Ilknur; Ravindran, Varadarajan; Pirbazari, Massoud

    2007-01-01

    A major technological concern with reverse osmosis in water purification, wastewater treatment, and water reclamation or recycling is the production of brine concentrates high in ammonia or nitrogen...

  20. Boron Removal in Seawater Reverse Osmosis System

    KAUST Repository

    Rahmawati, Karina

    2011-07-01

    Reverse osmosis successfully proves to remove more than 99% of solute in seawater, providing fresh water supply with satisfied quality. Due to some operational constraints, however, some trace contaminants removal, such as boron, cannot be achieved in one pass system. The stringent criterion for boron from World Health Organization (WHO) and Saudi Arabia local standard (0.5 mg/l) is hardly fulfilled by single pass sea water reverse osmosis (SWRO) plants. Some design processes have been proposed to deal with boron removal, but they are not economically efficient due to high energy and chemical consumption. The objective of this study was to study boron removal by different reverse osmosis membranes in two pH conditions, with and without antiscalant addition. Thus, it was expected to observe the possibility of operating single pass system and necessity to operate two pass system using low energy membrane. Five membrane samples were obtained from two different manufacturers. Three types of feed water pH were used, pH 8, pH 10, and pH 10 with antiscalant addition. Experiment was conducted in parallel to compare membrane performance from two manufacturers. Filtration was run with fully recycle mode for three days. Sample of permeate and feed were taken every 12 hours, and analyzed for their boron and TDS concentration. Membrane samples were also tested for their surface charge. The results showed that boron rejection increases as the feed pH increases. This was caused by dissociation of boric acid to negatively charged borate ion and more negatively charged membrane surface at elevated pH which enhance boron rejection. This study found that single pass reverse osmosis system, with and without elevating the pH, may not be possible to be applied because of two reasons. First, permeate quality in term of boron, does not fulfill WHO and local Saudi Arabia regulations. Second, severe scaling occurs due to operation in alkaline condition, since Ca and Mg concentration are

  1. Effects of surface coating process conditions on the water permeation and salt rejection properties of composite polyamide reverse osmosis membranes

    KAUST Repository

    Louie, Jennifer Sarah

    2011-02-01

    The application of polymer surface coatings to improve the fouling resistance of reverse osmosis membranes tends to increase flow resistance across the membrane. This paper presents a systematic analysis on how membrane properties and performance are impacted by the coating process steps, and investigates how such effects could contribute to lower water flux. On one hand, simply pre-soaking dry aromatic polyamide composite membranes in aliphatic alcohols results in a significant increase in water flux, which is attributed to wetting of pores in the selective polyamide layer and to changes in the polymer structure. This flux increase was not readily reversible, based on a 300-h water permeation test. Conversely, drying a wetted membrane led to a decrease in water flux, which we hypothesize is caused by increased interchain hydrogen-bonding in the selective layer. This drop in water flux was not permanent; higher flux was observed if the same wetted/dried membrane was then re-soaked in ethanol prior to the water permeation experiment. An ethanol pre-soaking step also increased water flux of a PEBAX-coated membrane by nearly 70%. In contrast to the reduction in water flux caused by the specific treatment sequence of ethanol-swelling followed by drying, this same sequence actually increased gas transport. The eight- to ten-fold increase in Knudsen diffusion-based gas permeance after this pre-treatment was attributed to an increase in the number or size of membrane defects. © 2010 Elsevier B.V.

  2. Reverse-osmosis membranes by plasma polymerization

    Science.gov (United States)

    Hollahan, J. R.; Wydeven, T.

    1972-01-01

    Thin allyl amine polymer films were developed using plasma polymerization. Resulting dry composite membranes effectively reject sodium chloride during reverse osmosis. Films are 98% sodium chloride rejective, and 46% urea rejective.

  3. Nanofiltration in Transforming Surface Water into Healthy Water: Comparison with Reverse Osmosis

    Directory of Open Access Journals (Sweden)

    L. D. Naidu

    2015-01-01

    Full Text Available The natural surface water, especially available through rivers, is the main source of healthy water for the living beings throughout the world from ancient days as it consists of all essential minerals. With the advent of industrialization, gradually even the most prominent rivers have been polluted in all parts of the world. Although there are lots of technologies, nanofiltration (NF has been chosen to transform river water into healthy water due to its unique advantages of retaining optimum TDS (with essential minerals required for human body, consuming of lower energy, and no usage of any chemicals. The prominent parameters of surface water and macro/microminerals of treated water have been analyzed. It is shown that NF is better in producing healthy water with high flux by consuming low energy.

  4. Novel technologies for reverse osmosis concentrate treatment: a review.

    Science.gov (United States)

    Joo, Sung Hee; Tansel, Berrin

    2015-03-01

    Global water shortages due to droughts and population growth have created increasing interest in water reuse and recycling and, concomitantly, development of effective water treatment processes. Pressured membrane processes, in particular reverse osmosis, have been adopted in water treatment industries and utilities despite the relatively high operational cost and energy consumption. However, emerging contaminants are present in reverse osmosis concentrate in higher concentrations than in the feed water, and have created challenges for treatment of the concentrate. Further, standards and guidelines for assessment and treatment of newly identified contaminants are currently lacking. Research is needed regarding the treatment and disposal of emerging contaminants of concern in reverse osmosis concentrate, in order to develop cost-effective methods for minimizing potential impacts on public health and the environment. This paper reviews treatment options for concentrate from membrane processes. Barriers to emerging treatment options are discussed and novel treatment processes are evaluated based on a literature review. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Pharmaceuticals and pesticides in reclaimed water: Efficiency assessment of a microfiltration-reverse osmosis (MF-RO) pilot plant.

    Science.gov (United States)

    Rodriguez-Mozaz, Sara; Ricart, Marta; Köck-Schulmeyer, Marianne; Guasch, Helena; Bonnineau, Chloe; Proia, Lorenzo; de Alda, Miren Lopez; Sabater, Sergi; Barceló, Damià

    2015-01-23

    Water reuse is becoming a common practice in several areas in the world, particularly in those impacted by water scarcity driven by climate change and/or by rising human demand. Since conventional wastewater treatment plants (WWTPs) are not able to efficiently remove many organic contaminants and pathogens, more advanced water treatment processes should be applied to WWTP effluents for water reclamation purposes. In this work, a pilot plant based on microfiltration (MF) followed by reverse osmosis (RO) filtration was applied to the effluents of an urban WWTP. Both the WWTP and the pilot plant were investigated with regards to the removal of a group of relevant contaminants widely spread in the environment: 28 pharmaceuticals and 20 pesticides. The combined treatment by the MF-RO system was able to quantitatively remove the target micropollutants present in the WWTP effluents to values either in the low ng/L range or below limits of quantification. Monitoring of water quality of reclaimed water and water reclamation sources is equally necessary to design the most adequate treatment procedures aimed to water reuse for different needs. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Evaluation of Military Field-Water Quality. Volume 7. Performance Evaluation of the 600-GPH Reverse Osmosis Water Purification Unit (ROWPU): reverse Osmosis (RO) Components

    Science.gov (United States)

    1986-02-01

    Biz detergent (manufactured by Procter and Gamble Chemical Company, Cincinnati, OH), containing sodium perborate , destroyed the membrane. 31 The...salt rejection and normalized product-water flow as a function of feed-water temperature for 3.2%- sodium -chloride feed solution at a pH - 7, 800-psig...as a function of feed-water pH for a 3.2%- sodium -chloride feed solution at 25°C, 800-psig applied pressure, and 1,75-gpm feed-water flow

  7. Bioluminescence-Based Method for Measuring Assimilable Organic Carbon in Pretreatment Water for Reverse Osmosis Membrane Desalination ▿

    Science.gov (United States)

    Weinrich, Lauren A.; Schneider, Orren D.; LeChevallier, Mark W.

    2011-01-01

    A bioluminescence-based assimilable organic carbon (AOC) test was developed for determining the biological growth potential of seawater within the reverse osmosis desalination pretreatment process. The test uses Vibrio harveyi, a marine organism that exhibits constitutive luminescence and is nutritionally robust. AOC was measured in both a pilot plant and a full-scale desalination plant pretreatment. PMID:21148685

  8. A comparison of ROChem reverse osmosis and spiral wound reverse osmosis membrane modules

    Energy Technology Data Exchange (ETDEWEB)

    Siler, J.L.

    1992-01-31

    Testing of the ROChem Disc Tube[reg sign] reverse osmosis (RO) module's performance on biologically active feed waters has been completed. Both the ROChem module (using Filmtec standard-rejection seawater membranes) and the Filmtec spiral-wound membrane module (using Filmtec high-rejection seawater membranes) were tested with stimulant solutions containing typical bacteria and metal hydroxide levels found in the F/H Effluent Treatment Facility (ETF) influent. Results indicate that the ROChem module gave superior performance over the spiral-wound module. Water flux losses were reduced by over 30% for water recoveries above 40%.

  9. A comparison of ROChem reverse osmosis and spiral wound reverse osmosis membrane modules

    Energy Technology Data Exchange (ETDEWEB)

    Siler, J.L.

    1992-01-31

    Testing of the ROChem Disc Tube{reg_sign} reverse osmosis (RO) module`s performance on biologically active feed waters has been completed. Both the ROChem module (using Filmtec standard-rejection seawater membranes) and the Filmtec spiral-wound membrane module (using Filmtec high-rejection seawater membranes) were tested with stimulant solutions containing typical bacteria and metal hydroxide levels found in the F/H Effluent Treatment Facility (ETF) influent. Results indicate that the ROChem module gave superior performance over the spiral-wound module. Water flux losses were reduced by over 30% for water recoveries above 40%.

  10. Hybrid membrane system for desalination and wastewater treatment : Integrating forward osmosis and low pressure reverse osmosis

    NARCIS (Netherlands)

    Valladares Linares, R.

    2014-01-01

    Since more than 97% of the water in the world is seawater, desalination technologies have the potential to solve the fresh water crisis. The most used desalination technology nowadays is seawater reverse osmosis (SWRO), where a membrane is used as a physical barrier to separate the salts from the

  11. On the potential of forward osmosis to energetically outperform reverse osmosis desalination

    OpenAIRE

    McGovern, Ronan Killian; Lienhard, John H.

    2014-01-01

    We provide a comparison of the theoretical and actual energy requirements of forward osmosis and reverse osmosis seawater desalination. We argue that reverse osmosis is significantly more energy efficient and that forward osmosis research efforts would best be fully oriented towards alternate applications. The underlying reason for the inefficiency of forward osmosis is the draw-dilution step, which increases the theoretical and actual energy requirements for draw regeneration. As a consequen...

  12. Fuzzy logic: applications to the pretreatment of brackish feed water in reverse osmosis treatment plants; Logica difusa: aplicaciones al pretratamiento del agua salobre de elimentacion de plantas desalladoras por osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Pluss Contino, J.; Simon Ruiz, J. L.; Hernandez, A.; Menendez Martinez, A.; Yaglian Steiner, E.; Menendez Fernandez, A.; Marcelo Cano, F.

    2004-07-01

    Frequently physical and chemical alteration that can suffer feed water composition and membranes behaviour of reverse osmosis desalination plants (RODP), define a vague nature system from the point of view of decision make process. In this work, we proposes the utilization of the approximate reasoning associated with the fuzzy logic, as an alternative to approach this problem and to make possible early corrective actions, that is, to do a proactive maintenance with Condition-based maintenance (CBM) technology. (Author) 21 refs.

  13. Nitrate-nitrogen removal with small-scale reverse osmosis ...

    African Journals Online (AJOL)

    The nitrate-nitrogen concentration in water supplied to clinics in Limpopo Province is too high to be fit for human consumption (35 to 75 mg/ℓ NO3-N). Therefore, small-scale technologies (reverse osmosis, ion-exchange and electrodialysis) were evaluated for nitrate-nitrogen removal to make the water potable (< 10 mg/ℓ ...

  14. The Impact of Integrated Aquifer Storage and Recovery and Brackish Water Reverse Osmosis (ASRRO on a Coastal Groundwater System

    Directory of Open Access Journals (Sweden)

    Steven Eugenius Marijnus Ros

    2017-04-01

    Full Text Available Aquifer storage and recovery (ASR of local, freshwater surpluses is a potential solution for freshwater supply in coastal areas, as is brackish water reverse osmosis (BWRO of relatively shallow groundwater in combination with deeper membrane concentrate disposal. A more sustainable and reliable freshwater supply may be achieved by combining both techniques in one ASRRO system using multiple partially penetrating wells (MPPW. The impact of widespread use of ASRRO on a coastal groundwater system was limited based on regional groundwater modelling but it was shown that ASRRO decreased the average chloride concentration with respect to the autonomous scenario and the use of BWRO. ASRRO was successful in mitigating the local negative impact (saltwater plume formation caused by the deep disposal of membrane concentrate during BWRO. The positive impacts of ASRRO with respect to BWRO were observed in the aquifer targeted for ASR and brackish water abstraction (Aquifer 1, but foremost in the deeper aquifer targeted for membrane concentrate disposal (Aquifer 2. The formation of a horizontal freshwater barrier was found at the top of both aquifers, reducing saline seepage. The disposal of relatively fresh concentrate in Aquifer 2 led to brackish water outflow towards the sea. The net abstraction in Aquifer 1 enforced saltwater intrusion, especially when BWRO was applied. The conclusion of this study is that ASRRO can provide a sustainable alternative for BWRO.

  15. Factors affecting fluoride and natural organic matter (NOM) removal from natural waters in Tanzania by nanofiltration/reverse osmosis.

    Science.gov (United States)

    Shen, Junjie; Schäfer, Andrea I

    2015-09-15

    This study examined the feasibility of nanofiltration (NF) and reverse osmosis (RO) in treating challenging natural tropical waters containing high fluoride and natural organic matter (NOM). A total of 166 water samples were collected from 120 sources within northern Tanzania over a period of 16 months. Chemical analysis showed that 81% of the samples have fluoride levels exceeding the WHO drinking guideline of 1.5mg/L. The highest fluoride levels were detected in waters characterized by high ionic strength, high inorganic carbon and on some occasions high total organic carbon (TOC) concentrations. Bench-scale experiments with 22 representative waters (selected based on fluoride concentration, salinity, origin and in some instances organic matter) and 6 NF/RO membranes revealed that ionic strength and recovery affected fluoride retention and permeate flux. This is predominantly due to osmotic pressure and hence the variation of diffusion/convection contributes to fluoride transport. Different membranes had distinct fluoride removal capacities, showing different raw water concentration treatability limits regarding the WHO guideline compliance. BW30, BW30-LE and NF90 membranes had a feed concentration limit of 30-40 mg/L at 50% recovery. NOM retention was independent of water matrices but is governed predominantly by size exclusion. NOM was observed to have a positive impact on fluoride removal. Several mechanisms could contribute but further studies are required before a conclusion could be drawn. In summary, NF/RO membranes were proved to remove both fluoride and NOM reliably even from the most challenging Tanzanian waters, increasing the available drinking water sources. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Disinfection byproduct formation in reverse-osmosis concentrated and lyophilized natural organic matter from a drinking water source.

    Science.gov (United States)

    Pressman, Jonathan G; McCurry, Daniel L; Parvez, Shahid; Rice, Glenn E; Teuschler, Linda K; Miltner, Richard J; Speth, Thomas F

    2012-10-15

    Drinking water treatment and disinfection byproduct (DBP) research can be complicated by natural organic matter (NOM) temporal variability. NOM preservation by lyophilization (freeze-drying) has been long practiced to address this issue; however, its applicability for drinking water research has been limited because the selected NOM sources are atypical of most drinking water sources. The purpose of this research was to demonstrate that reconstituted NOM from a lyophilized reverse-osmosis (RO) concentrate of a typical drinking water source closely represents DBP formation in the original NOM. A preliminary experiment assessed DBP formation kinetics and yields in concentrated NOM, which demonstrated that chlorine decays faster in concentrate, in some cases leading to altered DBP speciation. Potential changes in NOM reactivity caused by lyophilization were evaluated by chlorination of lyophilized and reconstituted NOM, its parent RO concentrate, and the source water. Bromide lost during RO concentration was replaced by adding potassium bromide prior to chlorination. Although total measured DBP formation tended to decrease slightly and unidentified halogenated organic formation tended to increase slightly as a result of RO concentration, the changes associated with lyophilization were minor. In lyophilized NOM reconstituted back to source water TOC levels and then chlorinated, the concentrations of 19 of 21 measured DBPs, constituting 96% of the total identified DBP mass, were statistically indistinguishable from those in the chlorinated source water. Furthermore, the concentrations of 16 of 21 DBPs in lyophilized NOM reconstituted back to the RO concentrate TOC levels, constituting 86% DBP mass, were statistically indistinguishable from those in the RO concentrate. This study suggests that lyophilization can be used to preserve concentrated NOM without substantially altering the precursors to DBP formation. Published by Elsevier Ltd.

  17. 21 CFR 177.2550 - Reverse osmosis membranes.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Reverse osmosis membranes. 177.2550 Section 177... Components of Articles Intended for Repeated Use § 177.2550 Reverse osmosis membranes. Substances identified in paragraph (a) of this section may be safely used as reverse osmosis membranes intended for use in...

  18. Obtaining high quality water by reverse osmosis. A comparison of the appropriate systems to be applied depending on the quality of the input water; Osmosis inversa para obtener agua de alta calidad. Comparacion de propuestas de sistemas de aplicacion en funcion de la calidad del agua de entrada

    Energy Technology Data Exchange (ETDEWEB)

    Pujadas Nino, A.

    2004-07-01

    This article first takes a brief look at the historical development of reverse osmosis systems. It then used several actual examples to compare the water quality that can be obtained using osmosis membranes and ion exchange resin demineralisation systems. It concludes with a number of recommendations regarding the solutions to be adopted in order to obtain water of a specific quality depending on the quality of the available water. (Author) 6 refs.

  19. Experience in using thermal disinfection to remove viable bacteria and endotoxins in centraly distributed reverse osmosis water.

    Science.gov (United States)

    Alayoud, Ahmed; Hamzi, Mohamed Amine; Razkaoui, Abdelaziz; Benyahia, Mohammed

    2014-01-01

    The water used for dilution of hemodialysis concentrates has to meet official quality recommendations regarding microbiology and chemical parameters. To avoid chemical use and to simplify treatments, hot water has been used to control microbial contamination of water distribution systems. In this study we evaluated the efficacy of heat disinfection in maintaining the quality of dialysis water generated by reverse osmosis (RO). During the first part of the study, we consecutively used (1) continuous water circulation, (2) daily heat disinfection and (3) a combination of daily heat disinfection and weekly chemical disinfection while checking bacterial count and endotoxin level every 4-5 weeks. During the second part of the study, we continued using daily heat disinfection while checking bacterial count and endotoxin level on weekly basis. The endotoxin levels at all sampling points of the water treatment system were lower than 0.005/ ml throughout the study. The application of heat disinfection alone reduced bacterial levels but an escape phenomenon occurred. After an interval of 21 days, an exponential increase of bacterial count was noted and cultures from the RO unit revealed growth of Pseudomonas fluorescence. The addition of chemical disinfection was successful in eliminating micro-organisms. Throughout this study, micro-organisms and endotoxins were not detectable in dialysate fluid and substitution fluid in dialysis monitors. The isolation of a thermo-sensitive organism from the RO unit after a period of relying on thermal disinfection suggests the existence of dead space in the RO unit that is not adequately exposed to heat but is accessible to chemical disinfection. .

  20. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes

    Directory of Open Access Journals (Sweden)

    Michelle J. Alfa

    2017-11-01

    Full Text Available IntroductionSimulated-use buildup biofilm (BBF model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes.Materials and methodsBBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa. Sterile reverse osmosis (RO water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey–Engley were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes.ResultsDespite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF extraction provided significantly better recovery of E. coli (p = 0.02 from duodenoscope lever cavities compared to the CDC flush method.Discussion and conclusionWe recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.

  1. Assessment of nanofiltration and reverse osmosis potentialities to recover metals, sulfuric acid, and recycled water from acid gold mining effluent.

    Science.gov (United States)

    Ricci, Bárbara C; Ferreira, Carolina D; Marques, Larissa S; Martins, Sofia S; Amaral, Míriam C S

    This work assessed the potential of nanofiltration (NF) and reverse osmosis (RO) to treat acid streams contaminated with metals, such as effluent from the pressure oxidation process (POX) used in refractory gold ore processing. NF and RO were evaluated in terms of rejections of sulfuric acid and metals. Regarding NF, high sulfuric acid permeation (∼100%), was observed, while metals were retained with high efficiencies (∼90%), whereas RO led to high acid rejections (<88%) when conducted in pH values higher than 1. Thus, sequential use of NF and RO was proved to be a promising treatment for sulfuric acid solutions contaminated by metals, such as POX effluent. In this context, a purified acid stream could be recovered in NF permeate, which could be further concentrated in RO. Recovered acid stream could be reused in the gold ore processing or commercialized. A metal-enriched stream could be also recovered in NF retentate and transferred to a subsequent metal recovery stage. In addition, considering the high acid rejection obtained through the proposed system, RO permeate could be used as recycling water.

  2. Performance of tubular reverse osmosis for the desalination ...

    African Journals Online (AJOL)

    2007-12-12

    Dec 12, 2007 ... Municipal solid waste leachate (MSWL) has the potential to pollute the water environment and to affect biological treatment processes ... Keywords: reverse osmosis, leachate treatment, membrane fouling, membrane cleaning, effluent quality, .... The salinity (conductivity), COD, NH4-N, PO4-P and Na.

  3. Performance of tubular reverse osmosis for the desalination ...

    African Journals Online (AJOL)

    Municipal solid waste leachate (MSWL) has the potential to pollute the water environment and to affect biological treatment processes adversely if not properly handled. Reverse osmosis (RO) has the ability to remove both organics and inorganics effectively from effluents. Therefore, RO was evaluated for the treatment of ...

  4. Predicting flux decline of reverse osmosis membranes

    NARCIS (Netherlands)

    Schippers, J.C.; Hanemaayer, J.H.; Smolders, C.A.; Kostense, A.

    1981-01-01

    A mathematical model predicting flux decline of reverse osmosis membranes due to colloidal fouling has been verified. This mathema- tical model is based on the theory of cake or gel filtration and the Modified Fouling Index (MFI). Research was conducted using artificial colloidal solutions and a

  5. Oilfield water treatment by electrocoagulation-reverse osmosis for agricultural use: effects on germination and early growth characteristics of sunflower.

    Science.gov (United States)

    de Souza, Paulo S A; Cerqueira, Alexandre A; Rigo, Michelle M; de Paiva, Julieta L; Couto, Rafael S P; Merçon, Fábio; Perez, Daniel V; Marques, Monica R C

    2017-05-01

    This study aims to evaluate the effects of oilfield water (OW), treated by a hybrid process of electrocoagulation and reverse osmosis (EC-RO), on seed germination and early growth characteristics of sunflower (Heliantus annus L.). In the EC step, tests were conducted with 28.6 A m -2 current density and 4 min. reaction time. In the RO step, the system was operated with 1 L min -1 constant flow and 2 MPa, 2.5 MPa and 3 MPa feed pressures. In all feed pressures, RO polymeric membranes achieved very high removals of chemical oxygen demand (up to 89%) and oils and greases (100%) from EC-treated effluent. In best feed pressure (2.5 MPa), turbidity, total dissolved salts, electrical conductivity, salinity, toxic ions and sodium adsorption ratio values attained internationally recognized standards for irrigation water. Using EC-RO (feed pressure:2.5 MPa) treated OW, germinated sunflower seeds percentage (86 ± 6%), speed of germination (30 ± 2) and biomass production (49 ± 5 mg) were statistically similar to control (distilled water) results. Vigor index average values obtained using OW treated by EC-RO (3871)were higher than that obtained by OW water treated by EC (3300). The results of this study indicate that EC-RO seems to be a promising alternative for treatment of OW aiming sunflower crops irrigation, since the use of this treated effluent did not affect adversely seed germination and seedling development, and improved seedling vigor. Furthermore, OW treatment by EC-RO reduces sodium levels into acceptable standards values avoiding soil degradation.

  6. Evaluating the efficiency of different microfiltration and ultrafiltration membranes used as pretreatment for Red Sea water reverse osmosis desalination

    KAUST Repository

    Almashharawi, Samir

    2013-01-01

    Conventional processes are widely used as pretreatment for reverse osmosis (RO) desalination technology since its development. However, these processes require a large footprint and have some limitation issues such as difficulty to maintain a consistent silt density index, coagulation control at low total suspended solids, and management of higher waste sludge. Recently, there has been a rapid growth in the use of low-pressure membranes as pretreatment for RO systems replacing the conventional processes. However, despite the numerous advantages of using this integrated membrane system mainly providing good and stable water quality to RO membranes, many issues have to be addressed. The primary limitation is membrane fouling which reduces the permeate flux; therefore, higher pumping intensity is required to maintain a consistent volume of product. This paper aims to optimize the permeation flux and cleaning frequency by providing high permeate quality. Different low-pressure polyethersulfone membranes with different pore sizes ranging from 0.1 lm to 50 kDa were tested. Eight different filtration configurations have been applied including the variation of coagulant doses aiming to control membrane fouling. Results showed that all the configurations with/without coagulation, provided permeate with excellent water quality which improves the stability of RO performance. However, more stable fluxes with less-energy consumption were achieved by using the 0.1 lm and 100 kDa membranes with 1 mg/L FeCl3 coagulation. The use of UF membranes, having tight pores, without coagulation also proved to be an excellent option for Red Sea water RO pretreatment. © 2013 Desalination Publications.

  7. Performance evaluation of reverse osmosis desalination plants for rural water supply in a developing country--a case study.

    Science.gov (United States)

    Kelkar, P S; Joshi, V A; Ansari, M H; Manivel, U

    2003-12-01

    Performance evaluation of two reverse osmosis (RO) desalination plants (DSP) at villages: Melasirupodhu (30 m3 day(-1)) and Sikkal (50 m3 day(-1)) in Ramanathpuram district, Tamil Nadu (India) were studied so as to bring out the state-of-art of their operation and maintenance (O&M). Detailed information on plant design and engineering, water quality, plant personnel, and cost of O&M was collected for a period of three years after commissioning of the two plants. Feed water was brackish, the TDS varied in the range of 6500-8500 mg L(-1) at Melasirupodhu and 5300-7100 mg L(-1) at Sikkal villages. The product water quality was observed to be gradually deteriorating as the salt rejection by the membranes decreased with time. The salt rejection was 97-99% at the time of commissioning of the plants, and came down to 89-90% at the end of 3 years of operation. Product water TDS soon after installation of the plants was excellent and within desirable limits of BIS. After three years of operation, few parameters exceeded the desirable limits, however, they were found to be within permissible limits of BIS. The analyses of the data showed that both plants were operated only at 30-36% of the design capacity. Plant shut-down due to inadequate and erratic power supply, and plant break-down and inherent delay in repairs due to lack of adequate infrastructure were found to be the major causes for the low utilization of the plants. Consequently the recurring cost of product water production enhanced to Rs. 25.0/m3 at Melasirupodhu and Rs. 17.5 m(-3) at Sikkal, as against the estimated cost of Rs. 15.0/m3 and Rs. 11.0/m3, respectively, as per the design. Over the years, the energy consumption for the product water output increased reflecting higher operational pressures needed with the aging of the membranes.

  8. Aquifer composition and the tendency toward scale-deposit formation during reverse osmosis desalination - Examples from saline ground water in New Mexico, USA

    Science.gov (United States)

    Huff, G.F.

    2006-01-01

    Desalination is expected to make a substantial contribution to water supply in the United States by 2020. Currently, reverse osmosis is one of the most cost effective and widely used desalination technologies. The tendency to form scale deposits during reverse osmosis is an important factor in determining the suitability of input waters for use in desalination. The tendency toward scale formation of samples of saline ground water from selected geologic units in New Mexico was assessed using simulated evaporation. All saline water samples showed a strong tendency to form CaCO3 scale deposits. Saline ground water samples from the Yeso Formation and the San Andres Limestone showed relatively stronger tendencies to form CaSO4 2H2O scale deposits and relatively weaker tendencies to form SiO2(a) scale deposits than saline ground water samples from the Rio Grande alluvium. Tendencies toward scale formation in saline ground water samples from the Dockum Group were highly variable. The tendencies toward scale formation of saline waters from the Yeso Formation, San Andres Limestone, and Rio Grande alluvium appear to correlate with the mineralogical composition of the geologic units, suggesting that scale-forming tendencies are governed by aquifer composition and water-rock interaction. ?? 2006 Elsevier B.V. All rights reserved.

  9. Boron in reverse osmosis water desalination: current situational and applying technologies for its removal; El boro en las aguas desaladas por osmosis inversa: situacion actual y tecnologias aplicables para su eliminacion

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigo Sanz, M.; Penate Suarez, B.

    2007-07-01

    In most of the seawater reverse osmosis desalination plants operating in one stage, the water produced presents values bordering or exceeding the limit established by the Spanish legislation for boron content of 1mg/l. As well as on the intrinsic features of the membrane elements, the boron removal in the desalination process depends on various factors. In this article the most relevant ones are described and a synopsis of the applied technologies and designs is introduced in order to fulfil current regulations. (Author)

  10. APLIKASI TEKNOLOGI REVERSE OSMOSIS UNTUK PEMURNIAN AIR SKALA RUMAH TANGGA

    Directory of Open Access Journals (Sweden)

    Dessy Ariyanti

    2012-02-01

    Full Text Available Initially, commercially available reverse osmosis (RO systems were intended to use on ships for producing freshwater during long voyages. After the time, many developments have been conducted especially in membraneelement and system configuration. Such developments allow RO systems to be applied for home use with normalplumbing in households. A basic reverse osmosis system consists of a pressurized source of water, a membranesystem, and hoses of pipes that carry off and separate clean water and drain water. There are four types ofhousehold RO system, i.e.: undersink, whole house, multi family, farm and ranch. If a water quality problem isdue to several different contaminants, RO may be the most cost-effective method for their removal.

  11. Experimental Investigation of Solar Powered Reverse Osmosis ...

    African Journals Online (AJOL)

    One of the treatment options for an elevated total dissolved solution is desalination using a solar driven reverse osmosis system. The northern part of Ethiopia has short rainy season and long dry weather with clear sky radiation. Solar radiation ranges from 5.46 kWh/m2/day in August to 6.82 kWh/m2/day in April, with an ...

  12. International overview of seawater desalination plant by reverse osmosis technology

    OpenAIRE

    Kangwen, Shu

    2012-01-01

    Master's thesis in Environmental technology In a world faced with increased urbanization, population growth, climate change and degradation of water supplies, the importance of a reliable source of technology to provide fresh water emphasizes the importance of seawater desalination. Over the years a variety of seawater desalination methods have been developed throughout the world. The most common technologies available for desalination around the world are membrane reverse osmosis (RO),...

  13. International overview of seawater desalination plant by reverse osmosis technology

    OpenAIRE

    Kangwen, Shu

    2012-01-01

    In a world faced with increased urbanization, population growth, climate change and degradation of water supplies, the importance of a reliable source of technology to provide fresh water emphasizes the importance of seawater desalination. Over the years a variety of seawater desalination methods have been developed throughout the world. The most common technologies available for desalination around the world are membrane reverse osmosis (RO), thermal distillation (TD) and electrodialysis ...

  14. Remediating biofouling of reverse osmosis membranes

    Energy Technology Data Exchange (ETDEWEB)

    Siler, J.L.

    1991-10-22

    Several potential additives and the use of influent pH adjustment were examined to remediated the biofouling problem of the ETF reverse osmosis (RO) system. Tests were conducted with simulated RO feed containing salt, metal hydroxides and bacteria. The addition of sodium hexametaphosphate (SHMP), sodium bisulfite, and adjusting the influent pH to 3 were each successful in reducing the RO biofouling. Little or no benefit was found from the use of a biofilm remover (Filmtec Alkaline Cleaner) or the use of surfactants (Surfynol or sodium lauryl sulfate). In addition, Surfynol use resulted in irreversible fouling and necessitated membrane replacement. At the water recoveries used in the ETF (>90%), sodium bisulfite addition resulted in the recovery of 70--90% of the flux and almost complete restoration of the DF to prefouled conditions. Based on the bench-scale tests completed, IWT would recommend that sodium bisulfite addition be tested at the ETF. This testing would involve optimizing the amount of bisulfite required. In addition, it is recommended that the addition of SHMP or influent pH adjustment be evaluated since the relative differences in labscale tests were small and scale-up effects could be present. The ETF operating permit allows each to be added.

  15. Biofouling in reverse osmosis: phenomena, monitoring, controlling and remediation

    Science.gov (United States)

    Maddah, Hisham; Chogle, Aman

    2017-10-01

    This paper is a comprehensive review of biofouling in reverse osmosis modules where we have discussed the mechanism of biofouling. Water crisis is an issue of pandemic concern because of the steady rise in demand of drinking water. Overcoming biofouling is vital since we need to optimize expenses and quality of potable water production. Various kinds of microorganisms responsible for biofouling have been identified to develop better understanding of their attacking behavior enabling us to encounter the problem. Both primitive and advanced detection techniques have been studied for the monitoring of biofilm development on reverse osmosis membranes. Biofouling has a negative impact on membrane life as well as permeate flux and quality. Thus, a mathematical model has been presented for the calculation of normalized permeate flux for evaluating the extent of biofouling. It is concluded that biofouling can be controlled by the application of several physical and chemical remediation techniques.

  16. Lyophilization and Reconstitution of Reverse-Osmosis Concentrated Natural Organic Matter from a Drinking Water Source

    Science.gov (United States)

    Disinfection by-product (DBP) research can be complicated by difficulties in shipping large water quantities and changing natural organic matter (NOM) characteristics over time. To overcome these issues, it is advantageous to have a reliable method for concentrating NOM with min...

  17. Microbial community analysis of fouled reverse osmosis membranes used in water recycling

    KAUST Repository

    Ayache, C.

    2013-06-01

    Biofouling on RO membranes has major cost implications in water reclamation. In this study membranes and water samples were collected from a RO pilot-plant operated on two sites to study the differences in microbial communities in order to develop a better understanding of the biofouling. For the two sites studied, the examination of the front membrane of the first stage and the tail membrane of the second stage of the RO train using 16S rRNA gene-based molecular technique showed that bacteria were similar on both stages and no significant effect of the membrane location within the RO train on the biofilm development could be discerned. However, the comparison of the identified bacteria from membrane samples between the two sites showed that each site is specific, leading to a different composition of microbial communities. The different nutrient concentrations in the RO feed water due to the different biological pre-treatments are one potential explanation for the observed differences in the microbial communities. Seasonal variations also play a major role in the development of microbial communities as shown by the significant differences observed between the communities measured in the samples in winter and summer on the second site. The results did not show similarity between the species identified on the RO membranes and in the feed water. Hence, the relationship of microbial community between the water generated during the pre-treatment process and RO membranes is not obvious. From this study, results showed that there is an actual need to investigate the development of microbial communities on membrane surface in real conditions in order to suggest tailored solutions for biofouling control and removal. © 2013 Elsevier Ltd.

  18. Simultaneous Hydrogen Sulphide and Carbon Dioxide Removal from Biogas by Water-Swollen Reverse Osmosis Membrane

    Czech Academy of Sciences Publication Activity Database

    Dolejš, Petr; Poštulka, Václav; Sedláková, Zuzana; Jandová, Věra; Vejražka, Jiří; Esposito, E.; Jansen, J.C.; Izák, Pavel

    2014-01-01

    Roč. 131, JUN 27 (2014), s. 108-116 ISSN 1383-5866 R&D Projects: GA ČR GAP106/10/1194; GA ČR GA14-12695S; GA TA ČR TE01020080; GA MŠk LH14006; GA MŠk(CZ) 7C11009; GA MŠk(CZ) LD13018 Grant - others:RFCS(XE) RFCRCT-2010-00009; PONRC(IT) PON01_01840 Institutional support: RVO:67985858 Keywords : agro-biogas upgrading * biomethane * water vapour Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.091, year: 2014

  19. Utilization of reverse osmosis (RO) for reuse of MBR-treated wastewater in irrigation-preliminary tests and quality analysis of product water.

    Science.gov (United States)

    Bunani, Samuel; Yörükoğlu, Eren; Sert, Gökhan; Kabay, Nalan; Yüksel, Ümran; Yüksel, Mithat; Egemen, Özdemir; Pek, Taylan Özgür

    2015-02-19

    Membrane bioreactor (MBR) effluent collected from a wastewater treatment plant installed at an industrial zone was used for reverse osmosis (RO) membrane tests in the laboratory. For this, two different GE Osmonics RO membranes (AK-BWRO and AD-SWRO) were employed. The results showed that AK-brackish water reverse osmosis (AK-BWRO) and AD-seawater reverse osmosis (AD-SWRO) membranes have almost similar rejection performances regarding analyzed parameters such as conductivity, salinity, color, chemical oxygen demand (COD), and total organic carbon (TOC). On the other hand, these membranes behaved quite differently considering their permeate water flux at the same applied pressure of 10 bar. AD-SWRO membrane was also tested at 20 bar. The results revealed that AD-SWRO membrane had almost the same rejections either at 10 or at 20 bar of applied pressure. Compared with irrigation water standards, AK-BWRO and AD-SWRO gave an effluent with low salinity value and sodium adsorption ratio (SAR) which makes it unsuitable for irrigation due to the infiltration problems risi0ng from unbalanced values of salinity and SAR. Combination of MBR effluent and RO effluent at respective proportions of 0.3:0.7 and 0.4:0.6 for AK-BWRO and AD-SWRO, respectively, are the optimum mixing ratios to overcome the infiltration hazard problem. Choice of less-sensitive crops to chloride and sodium ions is another strategy to overcome all hazards which may arise from above suggested mixing proportions.

  20. Pilot study on arsenic removal from groundwater using a small-scale reverse osmosis system-Towards sustainable drinking water production.

    Science.gov (United States)

    Schmidt, Stefan-André; Gukelberger, Ephraim; Hermann, Mario; Fiedler, Florian; Großmann, Benjamin; Hoinkis, Jan; Ghosh, Ashok; Chatterjee, Debashis; Bundschuh, Jochen

    2016-11-15

    Arsenic contamination of groundwater is posing a serious challenge to drinking water supplies on a global scale. In India and Bangladesh, arsenic has caused the most serious public health issue in the world for nearly two decades. The aim of this work was to study an arsenic removal system based on reverse osmosis at pilot scale treating two different water sources from two different locations in the State of Bihar, India. For this purpose two villages, Bind Toli and Ramnagar in the Patna District were selected, both located very close to the river Ganga. The trials were conducted with aerated and non-aerated groundwater. It is the first time that the arsenic removal efficiency for aerated and non-aerated groundwater by reverse osmosis technology in combination with an energy-saving recovery system have been studied. As the principle of reverse osmosis requires a relatively high pressure, its energy demand is naturally high. By using an energy recovery system, this demand can be lowered, leading to an energy demand per liter permeate of 3-4Wh/L only. Due to high iron levels in the groundwater and as a consequence the precipitation of ferric (hydr)oxides, it was necessary to develop a granular media filter for the trials under aeration in order to protect the membrane from clogging. Two different materials, first locally available sand, and second commercially available anthracite were tested in the granular media filter. For the trials with aerated groundwater, total arsenic removal efficiency at both locations was around 99% and the arsenic concentration in permeate was in compliance with the WHO and National Indian Standard of 10μg/L. However, trials under anoxic conditions with non-aerated groundwater could not comply with this standard. Additionally a possible safe discharge of the reverse osmosis concentrate into an abandoned well was studied. It was observed that re-injection of reject water underground may offer a safe disposal option. However, long

  1. IMPACTS OF REVERSE OSMOSIS ON SOUTHEAST MILK MARKETS

    OpenAIRE

    Schiek, William A.; Babb, Emerson M.

    1989-01-01

    The Southeast is a net importer of milk and milk products. Milk must be imported from other regions at certain times of the year. Reverse osmosis (RO) is a new processing technology which could significantly reduce milk transportation costs between regions by removing half the water from raw milk prior to shipment. A network flow algorithm, which incorporates federal milk orders and solves for the least cost procurement pattern, was used to assess the impact of RO on southeast milk marketing ...

  2. Chemical treatment of commercial reverse osmosis membranes for use in FO

    Science.gov (United States)

    Commercially available reverse osmosis (RO) membranes – SW30HR, BW30, and AG – were chemically treated for use in forward osmosis (FO). Nitric acid, phosphoric acid, sulfuric acid, ethanol, and ethanol–acid–water ternary solutions were employed for the treatment. All three membra...

  3. Energy systems impacts of reverse osmosis and thermal desalination in Jordan

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg; Lund, Henrik; Mathiesen, Brian Vad

    2013-01-01

    others population and wealth increase and competitive water uses from agriculture and industry is causing many nations to turn to desalination technologies. This paper investigates a Jordanian energy scenario with two different desalination technologies; reverse osmosis (RO) driven by electricity...

  4. Synergistic efficiency of the desilication of brackish underground water in Saudi Arabia by coupling γ-radiation and Fenton process: Membrane scaling prevention in reverse osmosis process

    Science.gov (United States)

    Aljohani, Mohammed S.

    2017-12-01

    One of the main water resources in arid Saudi Arabia is underground water. However, this brackish water has high silica content which can cause a recalcitrant deposit on the membrane in the reverse osmosis units during its desalination. In this study, we examined the synergistic efficiency of the removal of silica from the Buwaib water sample, when combining two advanced oxidation processes, γ-irradiation and the Fenton process, using hydrogen peroxide and zero valent metal iron as source of Fe3+. This latter adsorbs effectively on silica and co-precipitate. The influence of absorbed dose, iron dosage and pH effect were investigated. This preliminary study showed that these attractive and effective hybrid processes are very efficient in removing silica.

  5. A study on reverse osmosis permeating treatment for yarn dyeing ...

    African Journals Online (AJOL)

    This paper presents a fuzzy linear regression model for estimation of reverse osmosis permeating parameters conditions. The proposed model can effectively take on non-crisp, fuzzy and crisp data. This study model used for estimation of reverse osmosis permeating parameters data from Tirupur examines the variables that ...

  6. A study on reverse osmosis permeating treatment for yarn dyeing ...

    African Journals Online (AJOL)

    use

    2011-12-07

    Dec 7, 2011 ... This paper presents a fuzzy linear regression model for estimation of reverse osmosis permeating parameters conditions. The proposed model can effectively take on non-crisp, fuzzy and crisp data. This study model used for estimation of reverse osmosis permeating parameters data from Tirupur examines ...

  7. A Reverse Osmosis System for an Advanced Separation Process Laboratory.

    Science.gov (United States)

    Slater, C. S.; Paccione, J. D.

    1987-01-01

    Focuses on the development of a pilot unit for use in an advanced separations process laboratory in an effort to develop experiments on such processes as reverse osmosis, ultrafiltration, adsorption, and chromatography. Discusses reverse osmosis principles, the experimental system design, and some experimental studies. (TW)

  8. Life cycle cost of a hybrid forward osmosis – low pressure reverse osmosis system for seawater desalination and wastewater recovery

    KAUST Repository

    Valladares Linares, Rodrigo

    2015-10-19

    In recent years, forward osmosis (FO) hybrid membrane systems have been investigated as an alternative to conventional high-pressure membrane processes (i.e. reverse osmosis (RO)) for seawater desalination and wastewater treatment and recovery. Nevertheless, their economic advantage in comparison to conventional processes for seawater desalination and municipal wastewater treatment has not been clearly addressed. This work presents a detailed economic analysis on capital and operational expenses (CAPEX and OPEX) for: i) a hybrid forward osmosis – low-pressure reverse osmosis (FO-LPRO) process, ii) a conventional seawater reverse osmosis (SWRO) desalination process, and iii) a membrane bioreactor – reverse osmosis – advanced oxidation process (MBR-RO-AOP) for wastewater treatment and reuse. The most important variables affecting economic feasibility are obtained through a sensitivity analysis of a hybrid FO-LPRO system. The main parameters taken into account for the life cycle costs are the water quality characteristics (similar feed water and similar water produced), production capacity of 100,000 m3 d−1 of potable water, energy consumption, materials, maintenance, operation, RO and FO module costs, and chemicals. Compared to SWRO, the FO-LPRO systems have a 21% higher CAPEX and a 56% lower OPEX due to savings in energy consumption and fouling control. In terms of the total water cost per cubic meter of water produced, the hybrid FO-LPRO desalination system has a 16% cost reduction compared to the benchmark for desalination, mainly SWRO. Compared to the MBR-RO-AOP, the FO-LPRO systems have a 7% lower CAPEX and 9% higher OPEX, resulting in no significant cost reduction per m3 produced by FO-LPRO. Hybrid FO-LPRO membrane systems are shown to have an economic advantage compared to current available technology for desalination, and comparable costs with a wastewater treatment and recovery system. Based on development on FO membrane modules, packing density, and

  9. Study of different pretreatments for reverse osmosis reclamation of a petrochemical secondary effluent.

    Science.gov (United States)

    Benito-Alcázar, C; Vincent-Vela, M C; Gozálvez-Zafrilla, J M; Lora-García, J

    2010-06-15

    Conventionally treated petrochemical wastewaters contain substantial quantities of hazardous pollutants. In addition, wastewater reuse is being enhanced as a consequence of the shortage of fresh water. Advanced petrochemical wastewater treatment for water reuse will reduce hazardous pollutants discharges as well as water consumption. Reverse osmosis is a suitable technology to obtain pure water. This work studies the adequacy of different pretreatments applied to a petrochemical secondary effluent to produce a suitable feeding for reverse osmosis treatment. The permeate obtained can be used in the petrochemical industry for different processes. In this work, several experiments (granulated activated carbon filtration, ultrafiltration, nanofiltration and granulated activated carbon filtration coupled with nanofiltration) were performed to improve the conventional pretreatment. Total organic carbon, chemical oxygen demand, turbidity and silt density index were used to evaluate water quality for reverse osmosis feeding. In granulated activated carbon filtration, all the measured parameters but silt density index indicated a good filtrate quality to feed reverse osmosis membranes. Although the ultrafiltration permeate obtained was suitable for reverse osmosis, nanofiltration and granulated activated carbon filtration coupled with NF provided a better effluent quality for reverse osmosis than the other pretreatments studied. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Solar Desalination System Model for Sizing of Photovoltaic Reverse Osmosis (PVRO)

    KAUST Repository

    Habib, Abdulelah

    2015-06-28

    The focus of this paper is to optimize the solar energy utilization in the water desalination process. Due to variable nature of solar energy, new system design is needed to address this challenge. Here, reverse osmosis units, as the electrical loads, are considered as an ON/OFF units to track these solar energy variations. Reverse osmosis units are different in sizes and numbers. Various combinations of reverse osmosis units in size and capacity provide different water desalination system performances. To assess each scenario of reverse osmosis units, the total capital cost and operation and maintenance (O&M) cost are considered. The implemented optimization algorithm search all of the possible scenarios to find the best solution. This paper deploys the solar irradiance data which is provided from west coast (Red Sea) of Saudi Arabia for model construction and optimization algorithm implementation.

  11. Open-source CFD model for optimization of forward osmosis and reverse osmosis membrane modules

    DEFF Research Database (Denmark)

    Gruber, Mathias Felix; Aslak, Ulf; Hélix-Nielsen, Claus

    2016-01-01

    Osmotic membrane separation processes are based on using semi-permeable membranes to remove solutes from a given feed solution. This can happen either as Reverse Osmosis (RO) where a hydraulic pressure is applied to drive separation across the membrane, or as Forward Osmosis (FO) where osmotic pr...

  12. Reserve osmosis and its application in water desalination; Osmosis inversa y su aplicacion en la desalacion de las aguas

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, I. [Departamento de Ingenieria Aplicada, EPS Universidad Murcia, Cartagena (Spain); Almela, L. [Departamento de Quimica Agricola, Universidad de Murcia, Murcia (Spain); Huete, J.

    1996-08-01

    The limited availability of water resources raises two fundamental issues: those of restructuring traditional irrigated land and scarching for new resources to alleviate water shortage. Among the diverse methods that can be utilized for the desalination of water, reverse osmosis is now of great importance. One the advantages of this techniques is that it can be applied equally to big installations as to smaller rural holdings. This paper briefly describes the different methods of desalination, placing emphasis on reverse osmosis. (Author) 8 refs.

  13. Evaluating the impacts of membrane type, coating, fouling, chemical properties and water chemistry on reverse osmosis rejection of seven nitrosoalklyamines, including NDMA.

    Science.gov (United States)

    Steinle-Darling, Eva; Zedda, Marco; Plumlee, Megan H; Ridgway, Harry F; Reinhard, Martin

    2007-09-01

    Reverse osmosis (RO) treatment has been found to be effective for a wide range of organics but generally small, polar, uncharged molecules such as N-nitrosodimethylamine (NDMA) can be poorly rejected. The rejection of seven N-nitrosoalkylamines with molecular masses in the range of 78-158Da, including NDMA, N-nitrosodiethylamine (NDEA), N-nitrosomethylethylamine (NMEA), N-nitrosodipropylamine (NDPA), N-nitrosodibutylamine (NDBA), N-nitrosopyrrolidine (NPyr), N-nitrosopiperidine (NPip) by three commercial brackish-water reverse osmosis membranes was studied in flat-sheet cells under cross-flow conditions. The membranes used were ESPA3 (Hydranautics), LFC3 (Hydranautics) and BW-30 (Dow/Filmtec), commonly used in water reuse applications. The effects of varying ionic strength and pH, dip-coating membranes with PEBAX 1657, a hydrophilic polymer, and artificial fouling with alginate on nitrosamine rejection were quantified. Rejection in deionized (DI) water increased with molecular mass from 56 to 70% for NDMA, to 80-91% for NMEA, 89-97% for NPyr, 92-98% for NDEA, and to beyond the detection limits for NPip, NDPA and NDBA. For the nitrosamines with quantifiable transmission, linear correlations (r(2)>0.97) were found between the number of methyl groups and the log(transmission), with factor 0.35 to 0.55 decreases in transmission per added methyl group. A PEBAX coating lowered the ESPA3 rejection of NDMA by 11% but increased the LFC3 and BW30 rejection by 6% and 15%, respectively. Artificially fouling ESPA3 membrane coupons with 170g/m(2) alginate decreased the rejection of NDMA by 18%. A feed concentration of 100mM NaCl decreased rejection of NDMA by 15% and acidifying the DI water feed to pH=3 decreased the rejection by 5%, whereas increasing the pH to 10 did not have a significant (p<0.05) effect.

  14. Rotating Reverse Osmosis for Wastewater Reuse

    Science.gov (United States)

    Lueptow, Richard M.; Yoon, Yeomin; Pederson, Cynthia

    2004-01-01

    Our previous work established the concept of a low-pressure rotating reverse osmosis membrane system. The rotation of the cylindrical RO filter produces shear and Taylor vortices in the annulus of the device that decrease the concentration polarization and fouling commonly seen with conventional RO filtration techniques. A mathematical model based on the film theory and the solution-diffusion model agrees well with the experimental results obtained using this first generation prototype. However, based on the model, the filtrate flux and contaminant rejection depend strongly on the transmembrane pressure. Therefore, the goal of our current work is to improve the flux of the device by increasing the transmembrane pressure by a factor of 3 to 4. In addition, the rejections for a wider variety of inorganic and organic compounds typically found in space mission wastewater are measured.

  15. Performance of aeolian generators driven reverse osmosis under autonomous operation mode for brackish water desalination; Desempenho de instalacoes de osmose reversa acionadas por geradores eolicos em modo autonomo para dessalinizacao de agua salobra

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Paulo; Freire, Cristiano [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Engenharia Eletrica

    1999-07-01

    This work analyses the elements influencing the performance of brackish water desalination by aeolian generators driven reverse osmosis, operating under autonomous regime considering the recent experiences and new technologies. The aspects of reduction in energy consumption and operation with one energy source of variable character are considered.

  16. Study on Gaining Fresh Water by Small Scale Reverse Osmosis Membrane with Photovoltaic Energy from Brackish Water

    OpenAIRE

    Takeyama, Kouichi

    2009-01-01

    Under frequent draughts and floods, many rainwater harvests as terraced paddy fields, dam− constructions, reservoirs, ponds, tanks, rivers and underground pools become more important. And the rapid urbanizations changed its water supply with much chlorine, which caused many water purifier users at home tap, and much drinkers of bottle water. And with many water treatments as by hollow fiber membrane, the final method for gaining freshwater becomes populous as desalination of clean sea water w...

  17. Characterization of Hemodialysis Reverse Osmosis Wastewater From Yazd Educational Hospitals

    Directory of Open Access Journals (Sweden)

    Mohammad Saleh Ali-Taleshi

    2016-05-01

    Full Text Available This paper evaluates the technical feasibility of reusing hemodialysis reverse osmosis wastewater from educational hospitals in Yazd, Iran, as an alternative water source. For this study, from October to December 2013, hemodialysis reverse osmosis wastewater samples were obtained from two dialysis facilities and analyzed for biochemical oxygen demand (BOD, chemical oxygen demand (COD, pH, and electrical conductivity (EC using standard methods. Furthermore, concentrations of heavy metals such as Ag, Ba, Cd, Cu, Pb, Se, and Zn were calculated. Results were analyzed using the one sample t-test and independent t-test in SPSS 16 software. Mean concentrations of Ag, Ba, Cd, Cu, Fe, Pb, Se, and Zn in the hemodialysis reverse osmosis wastewater were 0.0960, 0.0611, 0.0186, 0.3381, 0.2153, 0.2212, 0.4196, and 0.0667 mg/L at S. Dr. Rahnamoon hospital, and 0.0963, 0.0849, 0.0177, 0.2942, 0.2160, 0.1827, 0.3420, and 0.0867 mg/L at S. Sadoughi hospital, respectively. The results also showed that the important challenges for reusing hemodialysis wastewater were its high EC and the presence of some elements, such as Se and Pb. Unlike Se and Pb, the concentrations of the other parameters were below discharge emission standards. Because of the large volumes of water used in hemodialysis, it is important to study the potential for reusing or recycling it. Through evaluation of the technical feasibility of hemodialysis wastewater reuse, this study draws attention to this neglected issue, especially in hemodialysis therapy.

  18. Association of Vitamin B12 Deficiency and Use of Reverse Osmosis Processed Water for Drinking: A Cross-Sectional Study from Western India.

    Science.gov (United States)

    Gupta, Ekant Surendra; Sheth, Sanket Pranjivan; Ganjiwale, Jaishree Deepak

    2016-05-01

    Prevalence of Vitamin B12 deficiency has increased in community in recent time. Possibility is raised for new and yet unidentified factors being associated with this increased prevalence. One of these factors frequently questioned is use of Reverse Osmosis (RO) processed water for drinking. We aimed to study association of use of RO processed water for drinking with Vitamin B12 deficiency. This cross-sectional study was done at tertiary care centre of Western India. Total 250 participants were recruited after excluding those participants with known factors responsible for Vitamin B12 deficiency. Information about gender, type of diet, milk intake and duration, dairy product intake, use of RO water and Vitamin B12 level was collected. Total 70 (28%) participants out of 250 were having Vitamin B12 deficiency. Forty (50.6%) of 79 participants using RO water were Vitamin B12 deficient against 30 (17.5%) of 171 using other sources. Logistic regression analysis showed independent association between use of RO water and Vitamin B12 deficiency. Although association of male gender, milk quantity of less than 100 ml per day and duration of RO water intake with occurrence of Vitamin B12 deficiency was found statistically significant in univariate analysis, logistic regression analysis did not show significant association. Use of RO processed drinking water was associated with Vitamin B12 deficiency. This being cross- sectional study, further longitudinal studies with large sample size and taking confounding factors into consideration, are required to establish this association.

  19. Biogenic nanosilver incorporated reverse osmosis membrane for antibacterial and antifungal activities against selected pathogenic strains: an enhanced eco-friendly water disinfection approach.

    Science.gov (United States)

    Manjumeena, R; Duraibabu, D; Sudha, J; Kalaichelvan, P T

    2014-01-01

    Reverse osmosis (RO) membranes have been used extensively in water desalination plants, waste water treatment in industries, agricultural farms and drinking water production applications. The objective of this work is to impart antibacterial and antifungal activities to commercially available RO membrane used in water purification systems by incorporating biogenic silver nanoparticles(AgNPs) synthesized using Rosa indica wichuriana hybrid leaf extract. The morphology and surface topography of uncoated and AgNPs-coated RO membrane were studied using Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Elemental composition of the AgNPs-coated RO membrane was analyzed by energy-dispersive X-ray spectroscopy (EDAX). The functional groups were identified by Fourier Transform Infrared spectroscopy (FT-IR). Hydrophilicity of the uncoated and AgNPs-coated RO membrane was analyzed using water contact angle measurements. The thermal properties were studied by thermogravimetric analysis (TGA). The AgNPs incorporated RO membrane exhibited good antibacterial and antifungal activities against pathogenic bacterial strains such as E. coli, S. aureus, M. luteus, K. pneumoniae, and P. aeruginosa and fungal strains such as Candida tropicalis, C. krusei, C. glabrata, and C. albicans.

  20. Molecular Characterization of the Bacterial Communities in the Different Compartments of a Full-Scale Reverse-Osmosis Water Purification Plant ▿

    Science.gov (United States)

    Bereschenko, L. A.; Heilig, G. H. J.; Nederlof, M. M.; van Loosdrecht, M. C. M.; Stams, A. J. M.; Euverink, G. J. W.

    2008-01-01

    The origin, structure, and composition of biofilms in various compartments of an industrial full-scale reverse-osmosis (RO) membrane water purification plant were analyzed by molecular biological methods. Samples were taken when the RO installation suffered from a substantial pressure drop and decreased production. The bacterial community of the RO membrane biofilm was clearly different from the bacterial community present at other locations in the RO plant, indicating the development of a specialized bacterial community on the RO membranes. The typical freshwater phylotypes in the RO membrane biofilm (i.e., Proteobacteria, Cytophaga-Flexibacter-Bacteroides group, and Firmicutes) were also present in the water sample fed to the plant, suggesting a feed water origin. However, the relative abundances of the different species in the mature biofilm were different from those in the feed water, indicating that the biofilm was actively formed on the RO membrane sheets and was not the result of a concentration of bacteria present in the feed water. The majority of the microorganisms (59% of the total number of clones) in the biofilm were related to the class Proteobacteria, with a dominance of Sphingomonas spp. (27% of all clones). Members of the genus Sphingomonas seem to be responsible for the biofouling of the membranes in the RO installation. PMID:18621875

  1. Forward osmosis membrane modular configurations for osmotic dilution of seawater by forward osmosis and reverse osmosis hybrid system.

    Science.gov (United States)

    Kim, Jung Eun; Phuntsho, Sherub; Ali, Syed Muztuza; Choi, Joon Young; Shon, Ho Kyong

    2018-01-01

    This study evaluates various options for full-scale modular configuration of forward osmosis (FO) process for osmotic dilution of seawater using wastewater for simultaneous desalination and water reuse through FO-reverse osmosis (RO) hybrid system. Empirical relationship obtained from one FO membrane element operation was used to simulate the operational performances of different FO module configurations. The main limiting criteria for module operation is to always maintain the feed pressure higher than the draw pressure throughout the housing module for safe operation without affecting membrane integrity. Experimental studies under the conditions tested in this study show that a single membrane housing cannot accommodate more than four elements as the draw pressure exceeds the feed pressure. This then indicates that a single stage housing with eight elements is not likely to be practical for safe FO operation. Hence, six different FO modular configurations were proposed and simulated. A two-stage FO configuration with multiple housings (in parallel) in the second stage using same or larger spacer thickness reduces draw pressure build-up as the draw flow rates are reduced to half in the second stage thereby allowing more than four elements in the second stage housing. The loss of feed pressure (pressure drop) and osmotic driving force in the second stage are compensated by operating under the pressure assisted osmosis (PAO) mode, which helps enhance permeate flux and maintains positive pressure differences between the feed and draw chamber. The PAO energy penalty is compensated by enhanced permeate throughput, reduced membrane area, and plant footprint. The contribution of FO/PAO to total energy consumption was not significant compared to post RO desalination (90%) indicating that the proposed two-stage FO modular configuration is one way of making the FO full-scale operation practical for FO-RO hybrid system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Behavior of pharmaceuticals and drugs of abuse in a drinking water treatment plant (DWTP) using combined conventional and ultrafiltration and reverse osmosis (UF/RO) treatments

    Energy Technology Data Exchange (ETDEWEB)

    Boleda, Ma Rosa [AGBAR-Aiguees de Barcelona, Gral Batet 5-7, 08028 Barcelona (Spain); Galceran, Ma Teresa [University of Barcelona, Department Analytical Chemistry, Av. Diagonal 647, 08028 Barcelona (Spain); Ventura, Francesc, E-mail: fventura@agbar.es [AGBAR-Aiguees de Barcelona, Gral Batet 5-7, 08028 Barcelona (Spain)

    2011-06-15

    The behavior along the potabilization process of 29 pharmaceuticals and 12 drugs of abuse identified from a total of 81 compounds at the intake of a drinking water treatment plant (DWTP) has been studied. The DWTP has a common treatment consisting of dioxychlorination, coagulation/flocculation and sand filtration and then water is splitted in two parallel treatment lines: conventional (ozonation and carbon filtration) and advanced (ultrafiltration and reverse osmosis) to be further blended, chlorinated and distributed. Full removals were reached for most of the compounds. Iopromide (up to 17.2 ng/L), nicotine (13.7 ng/L), benzoylecgonine (1.9 ng/L), cotinine (3.6 ng/L), acetaminophen (15.6 ng/L), erythromycin (2.0 ng/L) and caffeine (6.0 ng/L) with elimination efficiencies {>=}94%, were the sole compounds found in the treated water. The advanced treatment process showed a slightly better efficiency than the conventional treatment to eliminate pharmaceuticals and drugs of abuse. - Highlights: > The presence of pharmaceuticals and drugs of abuse in surface water was demonstrated. > Elimination in both potabilization processes reached levels >99% for most compounds. > Four pharmaceuticals and three drugs of abuse survived the potabilization process. - The efficiency of potabilization processes to eliminate or transform pharmaceuticals and illicit drugs is evaluated.

  3. Reverse osmosis and ultrafiltration for recovery and reuse of larval rearing water in Anopheles arabiensis mass production: Effect of water quality on larval development and fitness of emerging adults.

    Science.gov (United States)

    Mamai, Wadaka; Hood-Nowotny, Rebecca; Maiga, Hamidou; Ali, Adel Barakat; Bimbile-Somda, Nanwintoun S; Soma, Diloma Dieudonné; Yamada, Hanano; Lees, Rosemary Susan; Gilles, Jeremie R L

    2017-06-01

    Countries around the world are showing increased interest in applying the sterile insect technique against mosquito disease vectors. Many countries in which mosquitoes are endemic, and so where vector control using the sterile insect technique may be considered, are located in arid zones where water provision can be costly or unreliable. Water reuse provides an alternate form of water supply. In order to reduce the cost of mass rearing of Anopheles arabiensis mosquitoes, the possibility of recycling and reusing larval rearing water was explored. The used rearing water ('dirty water') was collected after the tilting of rearing trays for collection of larvae/pupae, and larvae/pupae separation events and underwent treatment processes consisting of ultrafiltration and reverse osmosis. First-instar An. arabiensis larvae were randomly assigned to different water-type treatments, 500 larvae per laboratory rearing tray: 'clean' dechlorinated water, routinely used in rearing; dirty water; and 'recycled' dirty water treated using reverse osmosis and ultrafiltration. Several parameters of insect quality were then compared: larval development, pupation rate, adult emergence, body size and longevity. Water quality of the samples was analyzed in terms of ammonia, nitrite, nitrate, sulphate, dissolved oxygen, chloride, and phosphate concentrations after the larvae had all pupated or died. Surface water temperatures were also recorded continuously during larval development. Pupation rates and adult emergence were similar in all water treatments. Adult body sizes of larvae reared in recycled water were similar to those reared in clean water, but larger than those reared in the dirty larval water treatment, whereas the adult longevity of larvae reared in recycled water was significantly increased relative to both 'clean' and 'dirty' water. Dirty larval water contained significantly higher concentrations of ammonium, sulfate, phosphate and chloride and lower levels of dissolved

  4. A 5 year longitudinal study of water quality for final rinsing in the single chamber washer-disinfector with a reverse osmosis plant.

    Science.gov (United States)

    Uetera, Yushi; Kishii, Kozue; Yasuhara, Hiroshi; Kumada, Naohito; Moriya, Kyoji; Saito, Ryoichi; Okazaki, Mitsuhiro; Misawa, Yoshiki; Kawamura, Kunio

    2013-01-01

    This report deals with the construction and management of the reverse osmosis (RO) water system for final rinsing of surgical instruments in the washer-disinfector. Numerous operational challenges were encountered in our RO water system and these were analyzed utilizing the Ishikawa Fishbone diagram. The aim was to find potential problems and promote preventive system management for RO water. It was found that the measures that existed were inappropriate for preventing contamination in the heat-labile RO water system. The storage tank was found to be significantly contaminated and had to be replaced with a new one equipped with a sampling port and water drainage system. Additional filters and an UV treatment lamp were installed. The whole system disinfection started 1.5 years later using a peracetic acid-based compound after confirming the material compatibility. Operator errors were found when a new water engineer took over the duty from his predecessor. It was also found that there were some deficiencies in the standard operating procedures (SOPs), and that on-the-job training was not enough. The water engineer failed to disinfect the sampling port and water drainage system. The RO membrane had been used for 4 years, even though the SOP standard specified changing it as every 3 years. Various bacteria, such as Rothia mucilaginosa, were cultured from the RO water sampled from the equipment. Because Rothia mucilaginosa is a resident in the oral cavity and upper respiratory tract, it is believed that the bacteria were introduced into the system by the maintenance personnel or working environment. Therefore, the presence of R. mucilaginosa implied the failure of sanitary maintenance procedures. This study suggests that water systems should be designed based on the plans for profound system maintenance. It also suggests that SOP and on-the job training are essential to avoid any operator errors. These results must be carefully considered when either constructing new

  5. Optimisation of the cleaning sequence for reverse osmosis membranes; Optimizacion de secuencias de lavado de membranas de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Hassani Zerrouk, M.; Quiroga Alonso, J. M.; Lopez Ramirez, J. A.

    2005-07-01

    Membranes used in water treatment lose performance along the time, in according to membrane kind, feed water characteristics and operating conditions. Fouling is the most important issue associated to membrane technology and for minimising it is necessary to clean membranes correctly. The main goal of this paper is to describe procedures and products that allow effective cleaning of reverse osmosis membranes, used to treat secondary effluents from activated sludges, which lead to a decrease in plant exploitation costs. (Author) 9 refs.

  6. Impact of elevated Ca(2+)/Mg(2+) concentrations of reverse osmosis membrane desalinated seawater on the stability of water pipe materials.

    Science.gov (United States)

    Liang, Juan; Deng, Anqi; Xie, Rongjing; Gomez, Mylene; Hu, Jiangyong; Zhang, Jufang; Ong, Choon Nam; Adin, Avner

    2014-03-01

    Hardness and alkalinity are known factors influencing the chemical stability of desalinated water. This study was carried out to investigate the effect of Ca(2+) and Mg(2+) on corrosion and/or scale formation on the surface of different water distribution pipe materials under tropical conditions. The corrosion rates of ductile iron, cast iron and cement-lined ductile iron coupons were examined in reverse osmosis (RO) membrane desalinated seawater which was remineralised using different concentrations of Ca(2+) and Mg(2+). The changes in water characteristics and the coupon corrosion rates were studied before and after the post-treatment. The corrosion mechanisms and corrosion products were examined using scanning electron microscope and X-ray diffraction, respectively. We found that the combination of Ca(2+) and Mg(2+) (60/40 mg/L as CaCO3) resulted in lower corrosion rates than all other treatments for the three types of pipe materials, suggesting that Ca(2+)/Mg(2+) combination improves the chemical stability of desalinated seawater rather than Ca(2+) only.

  7. Pilot-scale study on the treatment of basal aquifer water using ultrafiltration, reverse osmosis and evaporation/crystallization to achieve zero-liquid discharge.

    Science.gov (United States)

    Loganathan, Kavithaa; Chelme-Ayala, Pamela; Gamal El-Din, Mohamed

    2016-01-01

    Basal aquifer water is deep groundwater found at the bottom of geological formations, underlying bitumen-saturated sands. Some of the concerns associated with basal aquifer water at the Athabasca oil sands are the high concentrations of hardness-causing compounds, alkalinity, and total dissolved solids. The objective of this pilot-scale study was to treat basal aquifer water to a quality suitable for its reuse in the production of synthetic oil. To achieve zero-liquid discharge (ZLD) conditions, the treatment train included chemical oxidation, polymeric ultrafiltration (UF), reverse osmosis (RO), and evaporation-crystallization technologies. The results indicated that the UF unit was effective in removing solids, with UF filtrate turbidity averaging 2.0 NTU and silt density index averaging 0.9. Membrane autopsies indicated that iron was the primary foulant on the UF and RO membranes. Laboratory and pilot-scale tests on RO reject were conducted to determine the feasibility of ZLD crystallization. Due to the high amounts of calcium, magnesium, and bicarbonate in the RO reject, softening of the feed was required to avoid scaling in the evaporator. Crystals produced throughout the testing were mainly sodium chloride. The results of this study indicated that the ZLD approach was effective in both producing freshwater and minimizing brine discharges. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Behavior of pharmaceuticals and drugs of abuse in a drinking water treatment plant (DWTP) using combined conventional and ultrafiltration and reverse osmosis (UF/RO) treatments.

    Science.gov (United States)

    Boleda, M A Rosa; Galceran, M A Teresa; Ventura, Francesc

    2011-06-01

    The behavior along the potabilization process of 29 pharmaceuticals and 12 drugs of abuse identified from a total of 81 compounds at the intake of a drinking water treatment plant (DWTP) has been studied. The DWTP has a common treatment consisting of dioxychlorination, coagulation/flocculation and sand filtration and then water is splitted in two parallel treatment lines: conventional (ozonation and carbon filtration) and advanced (ultrafiltration and reverse osmosis) to be further blended, chlorinated and distributed. Full removals were reached for most of the compounds. Iopromide (up to 17.2 ng/L), nicotine (13.7 ng/L), benzoylecgonine (1.9 ng/L), cotinine (3.6 ng/L), acetaminophen (15.6 ng/L), erythromycin (2.0 ng/L) and caffeine (6.0 ng/L) with elimination efficiencies ≥ 94%, were the sole compounds found in the treated water. The advanced treatment process showed a slightly better efficiency than the conventional treatment to eliminate pharmaceuticals and drugs of abuse. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Poly/vinyl alcohol/ membranes for reverse osmosis

    Science.gov (United States)

    Katz, M. G.; Wydeven, T., Jr.

    1981-01-01

    A description is presented of the results of studies of the water and salt transport properties of PVA membranes, taking into account radiation crosslinked PVA membranes, diffusive salt permeability through PVA membranes, and heat treated PVA membranes. The experimental findings support an occurrence of independent water, and salt permeation processes. It is suggested that the salt permeation is governed by a solution-diffusion transport mechanism. The preparation of thin skinned, asymmetric PVA membranes is also discussed. The employed method has a certain similarity to the classical phase inversion method, which is widely applied in the casting of asymmetric reverse osmosis membranes. Instead of using a gelling bath composed of a nonsolvent for the membrane material and miscible with the solvent from which the membrane is cast, a 'complexing' bath is used, which is a solution of a complexing agent in water.

  10. Role of Reverse Divalent Cation Diffusion in Forward Osmosis Biofouling.

    Science.gov (United States)

    Xie, Ming; Bar-Zeev, Edo; Hashmi, Sara M; Nghiem, Long D; Elimelech, Menachem

    2015-11-17

    We investigated the role of reverse divalent cation diffusion in forward osmosis (FO) biofouling. FO biofouling by Pseudomonas aeruginosa was simulated using pristine and chlorine-treated thin-film composite polyamide membranes with either MgCl2 or CaCl2 draw solution. We related FO biofouling behavior-water flux decline, biofilm architecture, and biofilm composition-to reverse cation diffusion. Experimental results demonstrated that reverse calcium diffusion led to significantly more severe water flux decline in comparison with reverse magnesium permeation. Unlike magnesium, reverse calcium permeation dramatically altered the biofilm architecture and composition, where extracellular polymeric substances (EPS) formed a thicker, denser, and more stable biofilm. We propose that FO biofouling was enhanced by complexation of calcium ions to bacterial EPS. This hypothesis was confirmed by dynamic and static light scattering measurements using extracted bacterial EPS with the addition of either MgCl2 or CaCl2 solution. We observed a dramatic increase in the hydrodynamic radius of bacterial EPS with the addition of CaCl2, but no change was observed after addition of MgCl2. Static light scattering revealed that the radius of gyration of bacterial EPS with addition of CaCl2 was 20 times larger than that with the addition of MgCl2. These observations were further confirmed by transmission electron microscopy imaging, where bacterial EPS in the presence of calcium ions was globular, while that with magnesium ions was rod-shaped.

  11. Life cycle cost of a hybrid forward osmosis - low pressure reverse osmosis system for seawater desalination and wastewater recovery.

    Science.gov (United States)

    Valladares Linares, R; Li, Z; Yangali-Quintanilla, V; Ghaffour, N; Amy, G; Leiknes, T; Vrouwenvelder, J S

    2016-01-01

    In recent years, forward osmosis (FO) hybrid membrane systems have been investigated as an alternative to conventional high-pressure membrane processes (i.e. reverse osmosis (RO)) for seawater desalination and wastewater treatment and recovery. Nevertheless, their economic advantage in comparison to conventional processes for seawater desalination and municipal wastewater treatment has not been clearly addressed. This work presents a detailed economic analysis on capital and operational expenses (CAPEX and OPEX) for: i) a hybrid forward osmosis - low-pressure reverse osmosis (FO-LPRO) process, ii) a conventional seawater reverse osmosis (SWRO) desalination process, and iii) a membrane bioreactor - reverse osmosis - advanced oxidation process (MBR-RO-AOP) for wastewater treatment and reuse. The most important variables affecting economic feasibility are obtained through a sensitivity analysis of a hybrid FO-LPRO system. The main parameters taken into account for the life cycle costs are the water quality characteristics (similar feed water and similar water produced), production capacity of 100,000 m(3) d(-1) of potable water, energy consumption, materials, maintenance, operation, RO and FO module costs, and chemicals. Compared to SWRO, the FO-LPRO systems have a 21% higher CAPEX and a 56% lower OPEX due to savings in energy consumption and fouling control. In terms of the total water cost per cubic meter of water produced, the hybrid FO-LPRO desalination system has a 16% cost reduction compared to the benchmark for desalination, mainly SWRO. Compared to the MBR-RO-AOP, the FO-LPRO systems have a 7% lower CAPEX and 9% higher OPEX, resulting in no significant cost reduction per m(3) produced by FO-LPRO. Hybrid FO-LPRO membrane systems are shown to have an economic advantage compared to current available technology for desalination, and comparable costs with a wastewater treatment and recovery system. Based on development on FO membrane modules, packing density, and

  12. Separation performance and interfacial properties of nanocomposite reverse osmosis membranes

    KAUST Repository

    Pendergast, MaryTheresa M.

    2013-01-01

    Four different types of nanocomposite reverse osmosis (RO) membranes were formed by interfacial polymerization of either polyamide (PA) or zeolite A-polyamide nanocomposite (ZA-PA) thin films over either pure polysulfone (PSf) or zeolite A-polysulfone nanocomposite (ZA-PSf) support membranes cast by wet phase inversion. All three nanocomposite membranes exhibited superior separation performance and interfacial properties relative to hand-cast TFC analogs including: (1) smoother, more hydrophilic surfaces (2) higher water permeability and salt rejection, and (3) improved resistance to physical compaction. Less compaction occurred for membranes with nanoparticles embedded in interfacially polymerized coating films, which adds further proof that flux decline associated with physical compaction is influenced by coating film properties in addition to support membrane properties. The new classes of nanocomposite membrane materials continue to offer promise of further improved RO membranes for use in desalination and advanced water purification. © 2011 Elsevier B.V.

  13. Molecular dynamics study of a polymeric reverse osmosis membrane.

    Energy Technology Data Exchange (ETDEWEB)

    Harder, E.; Walters, D. E.; Bodnar, Y. D.; Faibish, R. S.; Roux, B. (Nuclear Engineering Division); (Univ. of Chicago); (Rosalind Franklin Univ. of Medicine and Science)

    2009-07-30

    Molecular dynamics (MD) simulations are used to investigate the properties of an atomic model of an aromatic polyamide reverse osmosis membrane. The monomers forming the polymeric membrane are cross-linked progressively on the basis of a heuristic distance criterion during MD simulations until the system interconnectivity reaches completion. Equilibrium MD simulations of the hydrated membrane are then used to determine the density and diffusivity of water within the membrane. Given a 3 MPa pressure differential and a 0.125 {micro}m width membrane, the simulated water flux is calculated to be 1.4 x 10{sup -6} m/s, which is in fair agreement with an experimental flux measurement of 7.7 x 10{sup -6} m/s.

  14. Comparison of the removal of hydrophobic trace organic contaminants by forward osmosis and reverse osmosis.

    Science.gov (United States)

    Xie, Ming; Nghiem, Long D; Price, William E; Elimelech, Menachem

    2012-05-15

    We compared the rejection behaviours of three hydrophobic trace organic contaminants, bisphenol A, triclosan and diclofenac, in forward osmosis (FO) and reverse osmosis (RO). Using erythritol, xylose and glucose as inert reference organic solutes and the membrane pore transport model, the mean effective pore size of a commercial cellulose-based FO membrane was estimated to be 0.74 nm. When NaCl was used as the draw solute, at the same water permeate flux of 5.4 L/m(2) h (or 1.5 μm/s), the adsorption of all three compounds to the membrane in the FO mode was consistently lower than that in the RO mode. Rejection of bisphenol A and diclofenac were higher in the FO mode compared to that in the RO mode. Because the molecular width of triclosan was larger than the estimated mean effective membrane pore size, triclosan was completely rejected by the membrane and negligent difference between the FO and RO modes could be observed. The difference in the separation behaviour of these hydrophobic trace organics in the FO (using NaCl the draw solute) and RO modes could be explained by the phenomenon of retarded forward diffusion of solutes. The reverse salt flux of NaCl hinders the pore diffusion and subsequent adsorption of the trace organic compounds within the membrane. The retarded forward diffusion effect was not observed when MgSO(4) and glucose were used as the draw solutes. The reverse flux of both MgSO(4) and glucose was negligible and thus both adsorption and rejection of BPA in the FO mode were identical to those in the RO mode. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  15. The pre-treatment of water in a reverse osmosis system. Its significant importance in the design and management of the process; Pretratamiento del agua en un sistema de osmosis inversa. Su significada importancia dentro del diseno y gestion del proceso

    Energy Technology Data Exchange (ETDEWEB)

    Pujadas, A.

    2001-07-01

    The practical application of reverse osmosis technology is really easy and facilities should function without serious problems. The real difficulty is presented by the pre-treatment and conditioning of water before entering the membrane system. The present article enumerates the series of most habitual problems presented by medium or low-saline water for its correct treatment in a reverse osmosis system, also enumerating the most habitual pre-treatments for overcoming them. The conclusion of all of this is that it is necessary to haven a good laboratory available, one that allows for a complete analysis of the water to be treated and a system for tracking the systems once they are in operation. (Author)

  16. Biofilm formation on reverse osmosis membranes is initiated and dominated by Sphingomonas spp

    NARCIS (Netherlands)

    Bereschenko, L.A.; Stams, A.J.M.; Euverink, G.J.W.; Loosdrecht, M.C.M.

    2010-01-01

    The initial formation and spatiotemporal development of microbial biofilm layers on surfaces of new and clean reverse osmosis (RO) membranes and feed-side spacers were monitored in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The feed water of

  17. Investigation of microbial adaptation to salinity variation for treatment of reverse osmosis concentrate by membrane bioreactor

    DEFF Research Database (Denmark)

    Jang, Duksoo; Moon, Chungman; Ahn, Kyuhong

    2014-01-01

    Even though reverse osmosis (RO) technologies are widely used for sustainable water reclamation, the control of concentrates containing a high concentration of dissolved matters originated from feed water should be considered. The effect of variations in salinity on biological wastewater treatment...

  18. The concentrating of alizarin using a reverse osmosis process

    Directory of Open Access Journals (Sweden)

    S. S. MADAENI

    2005-02-01

    Full Text Available Membrane technologies in general and reverse osmosis in particular have been employed for the concentrating of solutions. In this study, the concentrating of a heat sensitive alizarin extracted from madder root was realized using an FT30 reverse osmosis membrane. The effects of cross flow velocity, transmembrane pressure and pH on the flux and rejection were studied. Increasing the transmembrane pressure increased the flux while the rejection was constant. At pH 7–8, the highest flux was achieved. This study showed that reverse osmosis is the process of choice for the concentrating of alizarin solutions. The optimum operating conditions were 1.0 m/s crossflow velocity, 16 bars transmembrane pressure and pH 7. The system was tested for 12 h without severe fouling problems.

  19. Treatments of reverse osmosis concentrate using natural zeolites

    Directory of Open Access Journals (Sweden)

    Taherifar Hossein

    2015-06-01

    Full Text Available The purpose of the current study is to experimentally investigate the reduction of sodium adsorption ratio (SAR from a concentrated stream of reversed osmosis (RO using natural zeolites. In order to reduce the salinity of solution, experiments were carried out using zeolites of varying concentration, pretreatment of adsorbents, and the addition of Ethylenediaminetetraacetic acid (EDTA. The results show that both zeolites can be used in an RO brine treatment; however, Rhyolitic tuff is more effective than clinoptilolite for the reduction of water salinity. The experiments show that Rhyolitic tuff decreases salinity of RO concentrate to nearly one – third of the initial value. Statistical analyses show that the effect of zeolite concentration is negligible. Furthermore, the addition of EDTA and pretreatment of zeolite increase the SAR values.

  20. Preliminary design of seawater and brackish water reverse osmosis desalination systems driven by low-temperature solar organic Rankine cycles (ORC)

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Torres, Agustin M. [Dpto. Fisica Fundamental y Experimental, Electronica y Sistemas, Escuela Tecnica Superior de Ingenieria Civil e Industrial, Universidad de La Laguna (ULL), Avda. Astrofisico Francisco Sanchez s/n. 38206 La Laguna (Tenerife) (Spain); Garcia-Rodriguez, Lourdes [Dpto. Ingenieria Energetica, Universidad de Sevilla Escuela Tecnica Superior de Ingenieros, Camino de los Descubrimientos, s/n 41092 Sevilla (Spain)

    2010-12-15

    In this paper, the coupling between the low-temperature solar organic Rankine cycle (ORC) and seawater and brackish water reverse osmosis desalination units has been carried out. Four substances have been considered as working fluids of the solar cycle (butane, isopentane, R245fa and R245ca). With these four fluids the volumetric flow of fresh water produced per unit of aperture area of stationary solar collector has been calculated. The former has been made with the optimized direct vapour generation (DVG) configuration and heat transfer fluid (HTF) configuration of the solar ORC. In the first one (DVG), working fluid of the ORC is directly heated inside the absorber of the solar collector. In the second one (HTF), a fluid different than the working fluid of the ORC (water in this paper) is heated without phase change inside the absorber of the solar collector. Once this fluid has been heated it is carried towards a heat exchanger where it is cooled. Thermal energy delivered in this cooling process is transferred to the working fluid of the ORC. Influence of condensation temperature of the ORC and regeneration's process effectiveness over productivity of the system has also been analysed. Finally, parameters of several preliminary designs of the low-temperature solar thermal driven RO desalination are supplied. R245fa is chosen as working fluid of the ORC in these preliminary designs. The information of the proposed preliminary designs can also be used, i.e., for the assessment of the use of thermal energy rejected by the solar cycle. Overall analysis of the efficiency of the solar thermal driven RO desalination technology is given with the results presented in this paper and the results obtained with the medium temperature solar thermal RO desalination system presented by the authors in previous papers. This work has been carried out within the framework of the OSMOSOL and POWERSOL projects. (author)

  1. Evaluating the Efficiency of Different Microfiltration and Ultrafiltration Membranes Used as Pre-treatment for Reverse Osmosis Desalination of Red Sea Water

    KAUST Repository

    AlMashharawi, Samer

    2011-07-01

    . Collectively, results showed that all eight configurations provided permeate with excellent water quality to be fed to reverse osmosis membrane. However, using the 0.1 μm and 100kDa membranes with 1 mg/l FeCl3 concentration, respectively, steadier fluxes correspond to less increment of pumping intensity and better water quality was achieved.

  2. The feasibility of nanofiltration membrane bioreactor (NF-MBR)+reverse osmosis (RO) process for water reclamation: Comparison with ultrafiltration membrane bioreactor (UF-MBR)+RO process.

    Science.gov (United States)

    Tay, Ming Feng; Liu, Chang; Cornelissen, Emile R; Wu, Bing; Chong, Tzyy Haur

    2018-02-01

    This study examines the feasibility of a novel nanofiltration membrane bioreactor (NF-MBR) followed by reverse osmosis (RO) process for water reclamation at 90% recovery and using an ultrafiltration MBR (UF-MBR)+RO as baseline for comparison. Both MBRs adopted the same external hollow fiber membrane configurations and operating conditions. The collected permeates of the MBRs were subsequently fed to the respective RO systems. The results showed that the NF-MBR (operated at a constant flux of 10 L/m2h) achieved superior MBR permeate quality due to enhanced biodegradation and high rejection capacity of the NF membrane, leading to lower RO fouling rates (∼3.3 times) as compared to the UF-MBR. Further analysis indicated that the cake layer fouling that caused the cake-enhanced osmotic pressure (CEOP) effect contributed predominantly to the transmembrane pressure (TMP) increase in the NF-MBR, while irreversible pore fouling was the major reason for UF membrane fouling. Furthermore, it was found that the biopolymers (i.e., organics with MW > 10 kDa) were the main components present in the foulants of the NF/UF membranes and RO membranes. The analysis indicated that the NF-MBR + RO system at recovery of 90% has comparable energy consumption as the UF-MBR + RO system at recovery of 75%. Our findings proved the feasibility of the NF-MBR + RO for water reclamation at a high recovery rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Salinity-gradient power: Evaluation of pressure-retarded osmosis and reverse electrodialysis

    NARCIS (Netherlands)

    Post, Jan W.; Veerman, J.A.; Hamelers, Hubertus V.M.; Euverink, Gerrit J.W.; Metz, S.J.; Nijmeijer, Dorothea C.; Buisman, Cees J.N.

    2007-01-01

    A huge potential to obtain clean energy exists from mixing water streams with different salt concentrations. Two membrane-based energy conversion techniques are evaluated: pressure-retarded osmosis and reverse electrodialysis. From the literature, a comparison is not possible since the reported

  4. Salinity-gradient power : Evaluation of pressure-retarded osmosis and reverse electrodialysis

    NARCIS (Netherlands)

    Post, Jan W.; Veerman, Joost; Hamelers, Hubertus V.M.; Euverink, Gerrit J.W.; Metz, Sybrand J.; Nymeijer, Kitty; Buisman, Cees J.N.

    2007-01-01

    A huge potential to obtain clean energy exists from mixing water streams with different salt concentrations. Two membrane-based energy conversion techniques are evaluated: pressure-retarded osmosis and reverse electrodialysis. From the literature, a comparison is not possible since the reported

  5. Coagulation and ultrafiltration in seawater reverse osmosis pretreatment

    NARCIS (Netherlands)

    Tabatabai, S.A.A.

    2014-01-01

    Seawater desalination is a globally expanding coastal industry with an installed capacity of over 80 million m3/day. Algal blooms pose a challenge to the operation of seawater reverse osmosis (SWRO) membranes and pre-treatment systems due to high concentrations of algal cells and algal organic

  6. Application of reverse osmosis membrane system for treatment of ...

    African Journals Online (AJOL)

    The membrane selection process was theoretically designed using well known design software, like KOCH and ROSA. To design the treatment plant system based on the analytical report and software membrane, reverse osmosis (RO) system was used. To compare the experimental and theoretical (KOCH and ROSA ...

  7. Rejection mechanisms for contaminants in polymeric reverse osmosis membranes

    CERN Document Server

    Shen, Meng; Lueptow, Richard M

    2016-01-01

    Despite the success of reverse osmosis (RO) for water purification, the molecular-level physico-chemical processes of contaminant rejection are not well understood. Here we carry out NEMD simulations on a model polyamide RO membrane to understand the mechanisms of transport and rejection of both ionic and neutral contaminants in water. We observe that the rejection changes non-monotonously with ion sizes. In particular, the rejection of urea, 2.4 A radius, is higher than ethanol, 2.6 A radius, and the rejections for organic solutes, 2.2-2.8 A radius, are lower than Na+, 1.4 A radius, or Cl-, 2.3 A radius. We show that this can be explained in terms of the solute accessible intermolecular volume in the membrane and the solute-water pair interaction energy. If the smallest open spaces in the membrane's molecular structure are all larger than the hydrated solute, then the solute-water pair interaction energy does not matter. However, when the open spaces in the polymeric structure are such that solutes have to s...

  8. Disinfection Byproduct Formation in Reverse-Osmosis Concentrated and Lyophilized Natural Organic Matter from a Drinking Water Source

    Science.gov (United States)

    Drinking water treatment and disinfection byproduct (DBP) research can be complicated by natural organic matter (NOM) temporal variability. NOM preservation by lyophilization (freeze-drying) has been long practiced to address this issue; however, its applicability for drinking wa...

  9. Reverse osmosis treatment of wastes from the textile industry

    Energy Technology Data Exchange (ETDEWEB)

    Audran, J. [Electricite de France (EDF), 75 - Paris (France); Frizzarin, L.

    1995-09-01

    Reserve osmosis has been used in the textile industry for cleaning up effluent before sending it to the treatment plant. This process was preceded by a combination of flocculation and sedimentation. This system reduced water consumption since part of the water was reused, and also reduced the quantity of effluent to be dealt with by the treatment plant. (authors). 2 figs.

  10. Reverse osmosis brine for phosphorus recovery from source separated urine.

    Science.gov (United States)

    Tian, Xiujun; Wang, Guotian; Guan, Detian; Li, Jiuyi; Wang, Aimin; Li, Jin; Yu, Zhe; Chen, Yong; Zhang, Zhongguo

    2016-12-01

    Phosphorus (P) recovery from waste streams has recently been recognized as a key step in the sustainable supply of this indispensable and non-renewable resource. The feasibility of using brine from a reverse osmosis (RO) membrane unit treating cooling water as a precipitant for P recovery from source separated urine was evaluated in the present study. P removal efficiency, process parameters and precipitate properties were investigated in batch and continuous flow experiments. More than 90% of P removal was obtained from both undiluted fresh and hydrolyzed urines by mixing with RO brine (1:1, v/v) at a pH over 9.0. Around 2.58 and 1.24 Kg of precipitates could be recovered from 1 m 3 hydrolyzed and fresh urine, respectively, and the precipitated solids contain 8.1-19.0% of P, 10.3-15.2% of Ca, 3.7-5.0% of Mg and 0.1-3.5% of ammonium nitrogen. Satisfactory P removal performance was also achieved in a continuous flow precipitation reactor with a hydraulic retention time of 3-6 h. RO brine could be considered as urinal and toilet flush water despite of a marginally higher precipitation tendency than tap water. This study provides a widely available, low - cost and efficient precipitant for P recovery in urban areas, which will make P recovery from urine more economically attractive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Permeability of uncharged organic molecules in reverse osmosis desalination membranes.

    Science.gov (United States)

    Dražević, Emil; Košutić, Krešimir; Svalina, Marin; Catalano, Jacopo

    2017-06-01

    Reverse osmosis (RO) membranes are primarily designed for removal of salts i.e. for desalination of brackish and seawater, but they have also found applications in removal of organic molecules. While it is clear that steric exclusion is the dominant removal mechanism, the fundamental explanation for how and why the separation occurs remains elusive. Until recently there was no strong microscopic evidences elucidating the structure of the active polyamide layers of RO membranes, and thus they have been conceived as "black boxes"; or as an array of straight capillaries with a distribution of radii; or as polymers with a small amount of polymer free domains. The knowledge of diffusion and sorption coefficients is a prerequisite for understanding the intrinsic permeability of any organic solute in any polymer. At the same time, it is technically challenging to accurately measure these two fundamental parameters in very thin (20-300 nm) water-swollen active layers. In this work we have measured partition and diffusion coefficients and RO permeabilities of ten organic solutes in water-swollen active layers of two types of RO membranes, low (SWC4+) and high flux (XLE). We deduced from our results and recent microscopic studies that the solute flux of organic molecules in polyamide layer of RO membranes occurs in two domains, dense polymer (the key barrier layer) and the water filled domains. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Seawater reverse osmosis desalination and (harmful) algal blooms

    KAUST Repository

    Villacorte, Loreen O.

    2015-03-01

    This article reviews the occurrence of HABs in seawater, their effects on the operation of seawater reverse osmosis (SWRO) plants, the indicators for quantifying/predicting these effects, and the pretreatment strategies for mitigating operational issues during algal blooms. The potential issues in SWRO plants during HABs are particulate/organic fouling of pretreatment systems and biological fouling of RO membranes, mainly due to accumulation of algal organic matter (AOM). The presence of HAB toxins in desalinated water is also a potential concern but only at very low concentrations. Monitoring algal cell density, AOM concentrations and membrane fouling indices is a promising approach to assess the quality of SWRO feedwater and performance of the pretreatment system. When geological condition is favourable, subsurface intake can be a robust pretreatment for SWRO during HABs. Existing SWRO plants with open intake and are fitted with granular media filtration can improve performance in terms of capacity and product water quality, if preceded by dissolved air flotation or sedimentation. However, the application of advanced pretreatment using ultrafiltration membrane with in-line coagulation is often a better option as it is capable of maintaining stable operation and better RO feed water quality during algal bloom periods with significantly lower chemical consumption.

  13. PROSES RECOVERY BAHAN FLAVOR PADA LIMBAH CAIR PENGOLAHAN RAJUNGAN DENGAN TEKNOLOGI REVERSE OSMOSIS [Recovery of Flavor Components from Blue Crab Processing Wastewater by Reverse Osmosis Technology

    Directory of Open Access Journals (Sweden)

    Uju

    2008-06-01

    Full Text Available The waste water of blue crab pasteurization is potential to cause environmental pollution. It contained TSS 206.5 mg/L, BOD 7,092.6 mg/L and COD 51,000 mg/L. However the was te water also contains an interesting flavor compounds, which composed of 0.23% non protein nitrogen and 17 amino acids with the highest being glutamic acid. In this work, pre-filtration step using filter of 0.3 µ size followed by reverse osmosis has been used to reduce these pollutions load and recover the flavor compound. During pre-filtration steps, TSS was reduced to 74.8% so the turbidity increased up to 31%. After reverse osmosis process, BOD, and COD were decreased more than 99%, and there was no amino acids detected in the permeate stream. Factors that affect performance of reverse osmosis were transmembrane pressure, temperature and pH. Higher transmembrane pressure, temperature and pH resulted in the higher permeate flux.

  14. Reclaiming Water from Wastewater using Forward Osmosis

    NARCIS (Netherlands)

    Lutchmiah, K.

    2014-01-01

    Water scarcity is a global issue and waste accumulation is a steadily growing one. The innovative Sewer Mining concept, described in this thesis, is an example of an integrated forward osmosis application which incorporates different technologies to attain one goal: water recovery from wastewater,

  15. Does chlorination of seawater reverse osmosis membranes control biofouling?

    Science.gov (United States)

    Khan, Muhammad Tariq; Hong, Pei-Ying; Nada, Nabil; Croue, Jean Philippe

    2015-07-01

    Biofouling is the major problem of reverse osmosis (RO) membranes used for desalting seawater (SW). The use of chlorine is a conventional and common practice to control/prevent biofouling. Unlike polyamide RO membranes, cellulose triacetate (CTA) RO membranes display a high chlorine tolerance. Due to this characteristic, CTA membranes are used in most of the RO plants located in the Middle East region where the elevated seawater temperature and water quality promote the risk of membrane biofouling. However, there is no detailed study on the investigation/characterization of CTA-RO membrane fouling. In this investigation, the fouling profile of a full-scale SWRO desalination plant operating with not only continuous chlorination of raw seawater but also intermittent chlorination of CTA-RO membranes was studied. Detailed water quality and membrane fouling analyses were conducted. Profiles of microbiological, inorganic, and organic constituents of analysed fouling layers were extensively discussed. Our results clearly identified biofilm development on these membranes. The incapability of chlorination on preventing biofilm formation on SWRO membranes could be assigned to its failure in effectively reaching throughout the different regions of the permeators. This failure could have occurred due to three main factors: plugging of membrane fibers, chlorine consumption by organics accumulated on the front side fibers, or chlorine adaptation of certain bacterial populations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Does Chlorination of Seawater Reverse Osmosis Membranes Control Biofouling?

    KAUST Repository

    Khan, Muhammad Tariq

    2015-04-01

    Biofouling is the major problem of reverse osmosis (RO) membranes used for desalting seawater (SW). The use of chlorine is a conventional and common practice to control/prevent biofouling. Unlike polyamide RO membranes, cellulose triacetate (CTA) RO membranes display a high chlorine tolerance. Due to this characteristic, CTA membranes are used in most of the RO plants located in the Middle East region where the elevated seawater temperature and water quality promote the risk of membrane biofouling. However, there is no detailed study on the investigation/characterization of CTA-RO membrane fouling. In this investigation, the fouling profile of a full–scale SWRO desalination plant operating with not only continuous chlorination of raw seawater but also intermittent chlorination of CTA-RO membranes was studied. Detailed water quality and membrane fouling analyses were conducted. Profiles of microbiological, inorganic, and organic constituents of analysed fouling layers were extensively discussed. Our results clearly identified biofilm development on these membranes. The incapability of chlorination on preventing biofilm formation on SWRO membranes could be assigned to its failure in effectively reaching throughout the different regions of the permeators. This failure could have occurred due to three main factors: plugging of membrane fibers, chlorine consumption by organics accumulated on the front side fibers, or chlorine adaptation of certain bacterial populations.

  17. FATE OF REVERSE OSMOSIS (RO) MEMBRANES DURING OXIDATION BY DISINFECTANTS USED IN WATER TREATMENT: IMPACT ON MEMBRANE STRUCTURE AND PERFORMANCES

    KAUST Repository

    Maugin, Thomas

    2013-12-01

    Providing pretreatment prior RO filtration is essential to avoid biofouling and subsequent loss of membrane performances. Chlorine is known to degrade polymeric membrane, improving or reducing membrane efficiency depending on oxidation conditions. This study aimed to assess the impact of alternative disinfectant, NH2Cl, as well as secondary oxidants formed during chloramination of seawater, e.g. HOBr, HOI, or used in water treatment e.g. ClO2, O3, on membrane structure and performances. Permeability, total and specific rejection (Cl-, SO4 2-, Br-, Boron), FTIR profile, elemental composition were analyzed. Results showed that each oxidant seems to react differently with the membrane. HOCl, HOBr, ClO2 and O3 improved membrane permeability but decreased rejection in different extent. In comparison, chloramines resulted in identical trends but oxidized membrane very slowly. On the contrary, iodine improved membrane rejection e.g. boron, but decreased permeability. Reaction conducted with chlorine, bromine, iodine and chloramines resulted in the incorporation of halogen in the membrane structure. All oxidant except iodine were able to break amide bonds of the membrane structure in our condition. In addition, chloramine seemed to react with membrane differently, involving a potential addition of nitrogen. Chloramination of seawater amplified membrane performances evolutions due to generation of bromochloramine. Moreover, chloramines reacted both with NOM and membrane during oxidation in natural seawater, leading to additional rejection drop.

  18. Effect of the scale inhibitor on ion content in reverse osmosis system for seawater desalination

    Science.gov (United States)

    Gao, Yuhua; Liu, Zhenfa; Zhang, Lihui; Li, Haihua

    2017-09-01

    A scale inhibitor was synthesized from polysuccinimide with 2-aminoethanesulfonic acid and aspartic acid. The effect of scale inhibitor on ion content in reverse osmosis system for seawater desalination was studied. The results showed that the ion content of permeate water is lower with the scale inhibitor added in RO system for seawater desalination than without scale inhibitor. On the contrary, the ion content of concentrate water is higher when with scale inhibitor in RO system.

  19. Biofilm Formation on Reverse Osmosis Membranes Is Initiated and Dominated by Sphingomonas spp.▿ †

    OpenAIRE

    Bereschenko, L.A.; Stams, A. J. M.; Euverink, G.J.W.; Van Loosdrecht, C.M.

    2010-01-01

    The initial formation and spatiotemporal development of microbial biofilm layers on surfaces of new and clean reverse osmosis (RO) membranes and feed-side spacers were monitored in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The feed water of the RO system had been treated by the sequential application of coagulation, flocculation, sand filtration, ultrafiltration, and cartridge filtration processes. The design of the flow cells permitted...

  20. Modeling pH variation in reverse osmosis.

    Science.gov (United States)

    Nir, Oded; Bishop, Noga Fridman; Lahav, Ori; Freger, Viatcheslav

    2015-12-15

    The transport of hydronium and hydroxide ions through reverse osmosis membranes constitutes a unique case of ionic species characterized by uncommonly high permeabilities. Combined with electromigration, this leads to complex behavior of permeate pH, e.g., negative rejection, as often observed for monovalent ions in nanofiltration of salt mixtures. In this work we employed a rigorous phenomenological approach combined with chemical equilibrium to describe the trans-membrane transport of hydronium and hydroxide ions along with salt transport and calculate the resulting permeate pH. Starting from the Nernst-Planck equation, a full non-linear transport equation was derived, for which an approximate solution was proposed based on the analytical solution previously developed for trace ions in a dominant salt. Using the developed approximate equation, transport coefficients were deduced from experimental results obtained using a spiral wound reverse osmosis module operated under varying permeate flux (2-11 μm/s), NaCl feed concentrations (0.04-0.18 M) and feed pH values (5.5-9.0). The approximate equation agreed well with the experimental results, corroborating the finding that diffusion and electromigration, rather than a priori neglected convection, were the major contributors to the transport of hydronium and hydroxide. The approach presented here has the potential to improve the predictive capacity of reverse osmosis transport models for acid-base species, thereby improving process design/control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Behaviour of RO98pHt polyamide membrane in reverse osmosis and low reverse osmosis conditions for phenol removal.

    Science.gov (United States)

    Hidalgo, A M; León, G; Gómez, M; Murcia, M D; Gómez, E; Gómez, J L

    2011-10-01

    Phenolic compounds and their derivatives are very common pollutants in wastewaters. Among the methods described for their removal, pressure-driven membrane processes are considered as a reliable alternative. Our research group has previously studied phenol removal in reverse osmosis (RO) conditions and obtained very low rejection percentages. Subsequently, when low reverse osmosis (LRO) conditions were studied, the organic rejection percentages improved. To further our knowledge in this respect, the main objective of this work was to study the behaviour of the polyamide thin-film composite membrane RO98pHt used for phenol removal in RO and LRO conditions. The influence of different operating pressures, phenol feed concentrations and pH on permeate flux and phenol rejection was studied. Low reverse osmosis conditions led to higher phenol rejection percentages in all the assayed conditions, suggesting that other factors related to the molecular characteristics of the organic molecules, such as solubility, acidity and hydrogen bonding capacity, play an important role in the rejection percentage attained. As expected, permeate flux was greater in RO conditions.

  2. Study of the effectiveness of polyamide reverse osmosis membranes in the recovery of Cr(III) in tanning. Estudio sobre la efectividad de las membranas de osmosis inversa de poliamida en la recuperacion de Cr(III) en curticion

    Energy Technology Data Exchange (ETDEWEB)

    Galan, M.; Gonzalez, C.; Llorens, J.; Mans, C. (Barcelona Univ., Tarragona (Spain). Dept. d' Enginyeria Quimica i Bioqumica)

    1992-12-01

    Laboratory experiments on reverse osmosis using water containing Cr2(SO4)3 and a Film Tech Corporation TW30-2514 membrane are described. The type of cell employed allowed the membrane's rejection of Cr(III) to be measured with a high degree of accuracy. Tests were carried out varying the Cr concentration, the pressure and the temperature. The results obtained have implications regarding the suitability of reverse osmosis in recovering Cr from tanning waste water. (Author)

  3. Treatment calculation program for reverse osmosis facilities; Programa de calculo de tratamiento para instalaciones de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Adroer, M.; Bodas, J.; Coma, J.

    2001-07-01

    Reverse osmosis if a technique used ever more frequently for the desalination of water. it is very important to maintain the permeability of the membrane as much as possible throughout its life, and in order to do this, is necessary to know the incrustations properties of the water in contact with the membrane. The Adicro program has been developed to calculate the characteristics of this water from the analysis of the intake water, the type of membrane used, and the recovery percentage. It also calculates the necessary inhibitor doses and, finally, whether the supply water is apt for use in the plant under the predicted conditions or whether it should be modified. (Author) 2 refs.

  4. Reverse osmosis performance with solutions containing tri-n-butyl phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Siler, J.L.

    1991-10-22

    Tests were conducted to determine whether the reverse osmosis (RO) units at the F/H Effluent Treatment Facility (ETF) at the Savannah River could be made to process solutions containing tri-n-butyl phosphate (TBP). It was desired to test whether operation at a feed pH other than neutral would improve performance. Test results are discussed in this report and indicate that little improvement in the water flux can be expected at other pH values.

  5. Vacuum membrane distillation of seawater reverse osmosis brines.

    Science.gov (United States)

    Mericq, Jean-Pierre; Laborie, Stéphanie; Cabassud, Corinne

    2010-10-01

    Seawater desalination by Reverse Osmosis (RO) is an interesting solution for drinking water production. However, because of limitation by the osmotic pressure, a high recovery factor is not attainable. Consequently, large volumes of brines are discharged into the sea and the flow rate produced (permeate) is limited. In this paper, Vacuum Membrane Distillation (VMD) is considered as a complementary process to RO to further concentrate RO brines and increase the global recovery of the process. VMD is an evaporative technology that uses a membrane to support the liquid-vapour interface and enhance the contact area between liquid and vapour in comparison with conventional distillation. This study focuses on VMD for the treatment of RO brines. Simulations were performed to optimise the operating conditions and were completed by bench-scale experiments using actual RO brines and synthetic solutions up to a salt concentration of 300 g L(-1). Operating conditions such as a highly permeable membrane, high feed temperature, low permeate pressure and a turbulent fluid regime allowed high permeate fluxes to be obtained even for a very high salt concentration (300 g L(-1)). For the membrane studied, temperature and concentration polarisation were shown to have little effect on permeate flux. After 6 to 8 h, no organic fouling or biofouling was observed for RO brines. At high salt concentrations, scaling occurred (mainly due to calcium precipitation) but had only a limited impact on the permeate flux (24% decrease for a permeate specific volume of 43L m(-2) for the highest concentration of salt). Calcium carbonate and calcium sulphate precipitated first due to their low solubility and formed mixed crystal deposits on the membrane surface. These phenomena only occurred on the membrane surface and did not totally cover the pores. The crystals were easily removed simply by washing the membrane with water. A global recovery factor of 89% can be obtained by coupling RO and VMD

  6. In situ characterization of fouling in reverse osmosis membranes using electrical impedance spectroscopy

    Science.gov (United States)

    Chilcott, Terry; Antony, Alice; Coster, Hans; Leslie, Greg

    2013-04-01

    Analytical solutions of the Nernst-Planck, Poisson and continuity equations for a membrane undergoing reverse osmosis in a cross-flow system reveal that the flow of alternating ionic charge induced in the membrane during impedance measurements is actively assisted by the flow of water. The actively driven current manifested "inductive" responses in impedance measurements of a Filmtec BW30 reverse osmosis membrane mounted in an Inphaze flat-bed cross-flow module after 16 hours of filtering a mineral salt solution seeded with CaCl2 and NaHCO3 at pressure of 900 kPa. Fitted transfer functions resolved conduction and capacitive properties of four membrane layers, diffusion/concentration phenomenon and a pseudo "inductor" shunted by a conductor. A 10-fold decrease in the shunt conductance correlated with smaller increases in the conductance values for the filtrate and membranous layers, and the onset of fouling diagnosed by a rapid increase in flux decline.

  7. Separate and Concentrate Lactic Acid Using Combination of Nanofiltration and Reverse Osmosis Membranes

    Science.gov (United States)

    Li, Yebo; Shahbazi, Abolghasem; Williams, Karen; Wan, Caixia

    The processes of lactic acid production include two key stages, which are (a) fermentation and (b) product recovery. In this study, free cell of Bifidobacterium longum was used to produce lactic acid from cheese whey. The produced lactic acid was then separated and purified from the fermentation broth using combination of nanofiltration and reverse osmosis membranes. Nanofiltration membrane with a molecular weight cutoff of 100-400 Da was used to separate lactic acid from lactose and cells in the cheese whey fermentation broth in the first step. The obtained permeate from the above nanofiltration is mainly composed of lactic acid and water, which was then concentrated with a reverse osmosis membrane in the second step. Among the tested nanofiltration membranes, HL membrane from GE Osmonics has the highest lactose retention (97±1%). In the reverse osmosis process, the ADF membrane could retain 100% of lactic acid to obtain permeate with water only. The effect of membrane and pressure on permeate flux and retention of lactose/lactic acid was also reported in this paper.

  8. Flux dependency of particulate/colloidal fouling in seawater reverse osmosis systems

    KAUST Repository

    Salinas Rodríguez, S. G.

    2012-01-01

    Fouling is the main operational problem in seawater reverse osmosis systems (SWRO). Particulate fouling is traditionally measured through the silt density index (SDI) and through the modified fouling index (MFI). In recent years, ultrafiltration membranes were used successfully at constant flux-MFI-UF-to measure particulate/colloidal fouling potential and tested in sea water applications. Furthermore, constant flux operation allows predicting the rate of fouling in RO systems. The objectives of this study are: (1) to measure the flux effect in MFI-UF with different membranes (100, 30 and 10 kDa) for raw seawater and pre-treated water before reverse osmosis in three different locations; (2) to study the particulate and colloidal fouling potential of seawater in reverse osmosis systems; (3) to project the increase in pressure due to cake resistance in reverse osmosis systems. In this research, flat ultrafiltration membranes (100, 50, 30 and 10 kDa) are used in a con- stant flux filtration mode to test and compare real seawaters from various locations (North and Mediterranean Sea) and from various full scale facilities including different pre-treatments (i.e., ultrafiltration and coagulation + dual media filtration). The operated fluxes range from 350 down to values close to real RO operation, 15l(m2h)-1. After each filtration test, the MFI-UF is calculated to assess the particulate fouling potential. The obtained results showed that: (1) the particulate and colloidal fouling potential is directly proportional to the applied flux during filtration. This proportionality is related to the compression of the cake deposit occurring at high flux values; (2) the higher the flux, the higher the required pressure, the less porous the cake and therefore the higher the specific cake resistance; (3) particulate and colloidal fouling potential of seawater is site specific and is influenced by pre-treatment. © 2012 Desalination Publications. All rights reserved.

  9. ETV REPORT: EVALUATION OF HYDROMETRICS, INC., HIGH EFFICIENCY REVERSE OSMOSIS (HERO™) INDUSTRIAL WASTEWATER TREATMENT SYSTEM

    Science.gov (United States)

    Hydrometrics, founded in 1979 and located in Helena, MT, manufactures a commercial-ready High Efficiency Reverse Osmosis (HERO™) industrial wastewater treatment system. The system uses a three-stage reverse osmosis process to remove and concentrate metals for recovery while prod...

  10. Toward a reverse osmosis membrane system for recycling space mission wastewater.

    Science.gov (United States)

    Lee, S; Lueptow, R M

    2000-01-01

    Essential to extended human exploration and utilization of space is providing a clean supply of potable water as well as water for washing. Recycling of space mission wastewater is necessary for long-term space missions due to the limited capacity of water storage. In this study, initial measurements toward a wastewater reclamation system that provides a clean water supply using reverse osmosis (RO) membranes have been made using stirred cell filtration experiments. Low-pressure reverse osmosis (LPRO) membranes were used to obtain high flux of permeate as well as high rejection. Detergent removal was above 99%, and dissolved salt removal was above 90% in single-pass treatment, while total organic carbon (TOC) removal was nearly 80%. Most problematic is nitrogen rejection, which was 74% at best. Comparison of feed water before and after urea hydrolysis shows that the rejection of nitrogen compounds can be increased to 95% by allowing urea hydrolysis to occur. The removal efficiency for nitrogen compounds was also improved by increasing the shear rate near membrane surface. As a result, the product water in two passes could meet the hygiene water requirements for human space missions, and the product water in three passes could meet potable water regulations with overall recovery of 77%. This study also suggests that dynamic rotating membrane filtration, which can produce a high shear rate, will be useful to increase the system recovery as well as pollutant rejection. Grant numbers: NAG9-1053

  11. Teaching Mass Transfer and Filtration Using Crossflow Reverse Osmosis and Nanofiltration: An Experiment for the Undergraduate Unit Operations Lab

    Science.gov (United States)

    Anastasio, Daniel; McCutcheon, Jeffrey

    2012-01-01

    A crossflow reverse osmosis (RO) system was built for a senior-level chemical engineering unit operations laboratory course. Intended to teach students mass transfer fundamentals related to membrane separations, students tested several commercial desalination membranes, measuring water flux and salt rejections at various pressures, flow rates, and…

  12. Effect of conventional chemical treatment on the microbial population in a biofouling layer of reverse osmosis systems

    NARCIS (Netherlands)

    Bereschenko, L.A.; Prummel, H.; Euverink, G.J.W.; Stams, A.J.M.; Loosdrecht, van M.C.M.

    2011-01-01

    The impact of conventional chemical treatment on initiation and spatiotemporal development of biofilms on reverse osmosis (RO) membranes was investigated in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The flow cells got the same feed

  13. Designing a reverse osmosis desalination plant, main parameters and compounds; Diseno de una planta desilinizadora de osmosis inversa, parametros y componentes principales

    Energy Technology Data Exchange (ETDEWEB)

    Arango Mesa, H. [Universidad del Valle. Cali. Colombia (Colombia); Gomez Gotor, A. [Universidad de las Palmas de Gran Canaria (Spain)

    1998-12-31

    This paper comments on some of the design features which should be taken into account in planning a reverse osmosis sea water desalination plant. It also examine the components of some of the plant`s main units, such as the high pressure pumping unit and energy recovering system and the types of membrane modules and their use. Finally, it compares that most common commercially available products. (Author) 6 refs.

  14. Algal blooms: an emerging threat to seawater reverse osmosis desalination

    KAUST Repository

    Villacorte, Loreen O.

    2014-08-04

    Seawater reverse osmosis (SWRO) desalination technology has been rapidly growing in terms of installed capacity and global application over the last decade. An emerging threat to SWRO application is the seasonal proliferation of microscopic algae in seawater known as algal blooms. Such blooms have caused operational problems in SWRO plants due to clogging and poor effluent quality of the pre-treatment system which eventually forced the shutdown of various desalination plants to avoid irreversible fouling of downstream SWRO membranes. This article summarizes the current state of SWRO technology and the emerging threat of algal blooms to its application. It also highlights the importance of studying the algal bloom phenomena in the perspective of seawater desalination, so proper mitigation and preventive strategies can be developed in the near future. © 2014 © 2014 Balaban Desalination Publications. All rights reserved.

  15. Hydrophilic, bactericidal nanoheater-enabled reverse osmosis membranes to improve fouling resistance.

    Science.gov (United States)

    Ray, Jessica R; Tadepalli, Sirimuvva; Nergiz, Saide Z; Liu, Keng-Ku; You, Le; Tang, Yinjie; Singamaneni, Srikanth; Jun, Young-Shin

    2015-06-03

    Polyamide (PA) semipermeable membranes typically used for reverse osmosis water treatment processes are prone to fouling, which reduces the amount and quality of water produced. By synergistically coupling the photothermal and bactericidal properties of graphene oxide (GO) nanosheets, gold nanostars (AuNS), and hydrophilic polyethylene glycol (PEG) on PA reverse osmosis membrane surfaces, we have dramatically improved fouling resistance of these membranes. Batch fouling experiments from three classes of fouling are presented: mineral scaling (CaCO3 and CaSO4), organic fouling (humic acid), and biofouling (Escherichia coli). Systematic analyses and a variety of complementary techniques were used to elucidate fouling resistance mechanisms from each layer of modification on the membrane surface. Both mineral scaling and organic fouling were significantly reduced in PA-GO-AuNS-PEG membranes compared to other membranes. The PA-GO-AuNS-PEG membrane was also effective in killing all near-surface bacteria compared to PA membranes. In the PA-GO-AuNS-PEG membrane, the GO nanosheets act as templates for in situ AuNS growth, which then facilitated localized heating upon irradiation by an 808 nm laser inactivating bacteria on the membrane surface. Furthermore, AuNS in the membrane assisted PEG in preventing mineral scaling on the membrane surface. In flow-through flux and foulant rejection tests, PA-GO-AuNS-PEG membranes performed better than PA membranes in the presence of CaSO4 and humic acid model foulants. Therefore, the newly suggested membrane surface modifications will not only reduce fouling from RO feeds, but can improve overall membrane performance. Our innovative membrane design reported in this study can significantly extend the lifetime and water treatment efficacy of reverse osmosis membranes to alleviate escalating global water shortage from rising energy demands.

  16. Antiscaling efficacy of CaCO3 and CaSO4 on polyethylene glycol (PEG)-modified reverse osmosis membranes in the presence of humic acid: interplay of membrane surface properties and water chemistry.

    Science.gov (United States)

    Ray, Jessica R; Wong, Whitney; Jun, Young-Shin

    2017-02-15

    Mineral scaling persists in many water treatment processes. More specifically, it can significantly reduce the efficacy of aromatic polyamide (PA) membranes during reverse osmosis (RO) water treatment. Previous studies have integrated hydrophilic materials, such as polyethylene glycol (PEG), onto RO membranes to combat scaling from generally hydrophobic feed water constituents; however, there are still outstanding knowledge gaps regarding the interplay of the modified membrane surface chemistry and the water chemistry in complex RO feed waters. In this work, we have investigated the mechanisms of hydrophilic PEG-grafted PA membranes in reducing mineral scaling from calcium carbonate (CaCO3) and calcium sulfate (CaSO4) in the presence of humic acid (HA). Based on surface and solution analyses, we found that colloidal formation was significantly reduced on PA-PEG surfaces in systems without HA. When HA was introduced, CaCO3 scaling was reduced on both virgin and PA-PEG membrane surfaces; while, interestingly, synergistic PEG-HA-CaSO4 interactions increased CaSO4 colloidal formation on PA-PEG membranes. Promoted CaSO4 formation results from a high negative surface charge near the PEG-modified membrane surface when HA and SO4(2-) are present, attracting more Ca(2+) to form CaSO4. The results of this work provide new information about colloidal formation at water-membrane interfaces for designing better PEG and PEG-based scale-resistant desalination membranes.

  17. Reducing the environmental impacts of reverse osmosis desalination by using brackish groundwater resources.

    Science.gov (United States)

    Muñoz, Ivan; Fernández-Alba, Amadeo Rodríguez

    2008-02-01

    The aim of the present work is to find out whether or not, and to what extent, the environmental impacts of reverse osmosis desalination are reduced when brackish groundwater is used instead of sea water. In order to answer this question, the Life-Cycle Assessment (LCA) methodology is used, and two water production plants are compared. The brackish groundwater scenario is based on a plant located in Almería (southern Spain), while the sea water scenario is based on literature data. Four impact categories and two environmental indicators, one of them related to brine discharge, are included. The results show that the key life-cycle issue of brackish groundwater desalination is electricity consumption, and since this is substantially reduced with regard to using sea water, the life-cycle impacts are found to be almost 50% lower. An uncertainty analysis based on Monte-Carlo simulation shows that these environmental savings are significant for all impact categories. Potential local impacts provoked by brine discharge are also found to be lower, due to a reduced content of salts. It is concluded that, when and wherever possible, exploitation of brackish groundwater resources should be assigned priority to sea water resources as an input for reverse osmosis desalination, although it must be taken into account that groundwater, as opposed to sea water, is a limited resource.

  18. Reverse osmosis for the recovery of boric acid from the primary coolant at nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bártová, Šárka, E-mail: sarka.bartova@cvrez.cz [Research Centre Řež Ltd., Husinec-Řež 130, 250 68 Řež (Czech Republic); Kůs, Pavel [Research Centre Řež Ltd., Husinec-Řež 130, 250 68 Řež (Czech Republic); Skala, Martin [Research Centre Řež Ltd., Husinec-Řež 130, 250 68 Řež (Czech Republic); University of Chemical Technology, Prague, Department of Chemical Engineering, Technická 5, Prague 166 28 (Czech Republic); Vonková, Kateřina [Research Centre Řež Ltd., Husinec-Řež 130, 250 68 Řež (Czech Republic)

    2016-04-15

    Highlights: • RO membranes tested for boric acid recovery from primary coolant of nuclear power plants. • Scanning electron microscopy was used for the characterization of the membranes. • Lab scale experiments performed under various operation conditions. • We proposed configuration of and operation conditions for RO unit in nuclear power plant. - Abstract: At nuclear power plants (NPP), evaporators are used for the treatment of primary coolant and other liquid radioactive waste containing H{sub 3}BO{sub 3}. Because the operation of evaporators is expensive, a number of more cost-effective alternatives has been considered, one of which is reverse osmosis. We tested reverse osmosis modules from several manufactures on a batch laboratory apparatus. SEM images of the tested membranes were taken to distinguish the differences between the membranes. Water permeability through membranes was evaluated from the experiments with pure water. The experiments were performed with feed solutions containing various concentrations of H{sub 3}BO{sub 3} in a range commonly occurring in radioactive waste. The pH of the feed solutions ranged from 5.2 to 11.2. Our results confirmed that the pH of the feed solution plays the most important role in membrane separation efficiency of H{sub 3}BO{sub 3}. Certain modifications to the pH of the feed solution were needed to enable the tested membranes to concentrate the H{sub 3}BO{sub 3} in the retentate stream, separate from the pure water in the permeate stream. On this basis, we propose the configuration of and operational conditions for a reverse osmosis unit at NPP.

  19. The use of reverse osmosis at nuclear power plants. Replacement of evaporator

    Energy Technology Data Exchange (ETDEWEB)

    Kus, Pavel; Bartova, Sarka; Kunesova, Katerina; Smejdova, Vladena; Vonkova, Katerina [Research Centre Rez, Husinec-Rez (Czech Republic). Technological Circuits

    2015-06-01

    Evaporators are being used in nuclear power plants for the treatment of primary coolant containing H3BO3 for neutron absorption and other components for adjusting water chemistry. The aim is to achieve a concentrated H3BO3 solution, which is further purified by ion exchangers and then recycled into the primary cycle. Operation of evaporators is expensive, therefore reverse osmosis was proposed as one promising alternative. A pilot-plant RO unit was used for the experiments performed with feed solution. The successful technology is now being implemented at Temelin NPP.

  20. Surface modification of seawater desalination reverse osmosis membranes: Characterization studies & performance evaluation

    KAUST Repository

    Matin, Asif

    2014-06-01

    In this work we report surface modification of commercial reverse osmosis membranes by depositing ultrathin copolymer coatings, which could potentially enhance the biofouling resistance of RO membranes. Hydrophilic monomer hydroxyethyl methacrylate (HEMA) and a hydrophobic monomer, perfluorodecyl acrylate (PFDA) were copolymerized directly on the active layer of commercial aromatic polyamide reverse osmosis (RO) membranes using an initiated Chemical Vapor Deposition (iCVD) technique. Attenuated total reflective Fourier transform infrared spectra (ATR-FTIR) verified the successful modification of the membrane surfaces as a new FTIR adsorption band around 1730cm-1 corresponding to carbonyl groups in the copolymer film appeared after the deposition. X-ray Photoelectron spectroscopy (XPS) analysis also confirmed the presence of the copolymer film on the membrane surface by showing strong fluorine peaks emanating from the fluorinated alkyl side chains of the PFA molecules. Contact angle measurements with deionized water showed the modified membrane surfaces to be initially very hydrophobic but quickly assumed a hydrophilic character within few minutes. Atomic Force Microscopy (AFM) revealed that the deposited films were smooth and conformal as the surface topology of the underlying membrane surface remained virtually unchanged after the deposition. FESEM images of the top surface also showed that the typical ridge-and-valley structure associated with polyamide remained intact after the deposition. Short-term permeation tests using DI water and 2000ppm NaCl water showed that the deposited copolymer coatings had negligible effect on permeate water flux and salt rejection. © 2013 Elsevier B.V.

  1. Adsorption of Phosphonate Antiscalant from Reverse Osmosis Membrane Concentrate onto Granular Ferric Hydroxide

    NARCIS (Netherlands)

    Boels, L.; Keesman, K.J.; Witkamp, G.J.

    2012-01-01

    Adsorptive removal of antiscalants offers a promising way to improve current reverse osmosis (RO) concentrate treatment processes and enables the reuse of the antiscalant in the RO desalination process. This work investigates the adsorption and desorption of the phosphonate antiscalant

  2. Adhesion of a Mycobacterium sp. to cellulose diacetate membranes used in reverse osmosis.

    OpenAIRE

    Ridgway, H F; Rigby, M G; Argo, D G

    1984-01-01

    The kinetics of adhesion of a Mycobacterium sp. to cellulose diacetate reverse-osmosis membranes is described. This Mycobacterium sp. (strain BT2-4) was previously implicated in the initial stages of reverse-osmosis membrane biofouling at a wastewater reclamation facility. Adhesion of BT2-4 cells to the cellulose diacetate membrane surfaces occurred within 1 to 2 h at 30 degrees C and exhibited saturation-type kinetics which conformed closely to the Langmuir adsorption isotherm (Pearson r cor...

  3. Energy efficiency of batch and semi-batch (CCRO) reverse osmosis desalination.

    Science.gov (United States)

    Warsinger, David M; Tow, Emily W; Nayar, Kishor G; Maswadeh, Laith A; Lienhard V, John H

    2016-12-01

    As reverse osmosis (RO) desalination capacity increases worldwide, the need to reduce its specific energy consumption becomes more urgent. In addition to the incremental changes attainable with improved components such as membranes and pumps, more significant reduction of energy consumption can be achieved through time-varying RO processes including semi-batch processes such as closed-circuit reverse osmosis (CCRO) and fully-batch processes that have not yet been commercialized or modelled in detail. In this study, numerical models of the energy consumption of batch RO (BRO), CCRO, and the standard continuous RO process are detailed. Two new energy-efficient configurations of batch RO are analyzed. Batch systems use significantly less energy than continuous RO over a wide range of recovery ratios and source water salinities. Relative to continuous RO, models predict that CCRO and batch RO demonstrate up to 37% and 64% energy savings, respectively, for brackish water desalination at high water recovery. For batch RO and CCRO, the primary reductions in energy use stem from atmospheric pressure brine discharge and reduced streamwise variation in driving pressure. Fully-batch systems further reduce energy consumption by not mixing streams of different concentrations, which CCRO does. These results demonstrate that time-varying processes can significantly raise RO energy efficiency. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evaluation of the acerola juice concentrated by reverse osmosis

    Directory of Open Access Journals (Sweden)

    Eliane Rodrigues dos Santos Gomes

    2005-06-01

    Full Text Available The aim of this study was to obtain the acerola juice using separation processes with membranes. The acerola pulp was initially defrosted and treated with 100 ppm of Citrozym Ultra L enzyme at 45ºC for one hour, then ultrafiltrated at 3 bar at 45ºC using 0.1 µm ceramic membrane, and concentrated by reverse osmosis using a spiral membrane of a compound film. The pressures on the reverse osmosis were 20, 30, and 40 bar at environmental temperature, thus, resulting a juice with 9.76, 14.56, and 17.36 ºBrix, respectively. The physicochemical characteristics of the juice were preserved and, studies on evaluation of the public acceptability, showed that 75% of the consumers liked the juice.O objetivo deste trabalho foi à obtenção de suco de acerola utilizando processos de separação com membranas. Combinou-se a ultrafiltração e a osmose inversa, visando a melhoria do processo produtivo, utilizando-se uma tecnologia limpa. Para a acerola, visou-se manter e concentrar significativamente seu teor de vitamina C, obtendo-se um suco com sabor agradável, o mais próximo possível do suco in natura. A polpa de acerola foi inicialmente descongelada e tratada com 100 ppm da enzima Citrozym Ultra L, à 45º C por 1 hora e posteriormente ultrafiltrada a 3 bar na mesma temperatura em membrana cerâmica de 0,1 µm e na seqüência, concentrada por osmose inversa utilizando membrana espiral de filme composto. As pressões na osmose inversa foram 20, 30 e 40 bar em temperatura ambiente, obtendo-se um suco com 9,76, 14,56 e 17,36 ºBrix respectivamente. As características físico-químicas foram preservadas e na avaliação da aceitabilidade, 75% dos consumidores gostaram do suco, indicando boa aceitação.

  5. OPTIMASI DAN PEMODELAN PROSES RECOVER FLAVOR DARI LIMBAH CAIR INDUSTRI PENGOLAHAN RAJUNGAN DENGAN REVERSE OSMOSIS

    Directory of Open Access Journals (Sweden)

    Uju

    2009-04-01

    Full Text Available The waste water of blue crab pasteurization has potential in environmental pollution. It contained TSS of 206.5mg.1-1, BOD 7,092.6mg.1-1 and COD of 51,000mg.1-1. on the other hand, it also contains an interesting flavor compound, which composed of 0.23% non protein nitrogen and 17 amino acids where the highest was glutamic acid one. In this study, pre-filtration step using filter size 0.3 µ followed by reverse osmosis has been used to reduce these pollutions load and flavor compound recovery. During pre-filtration steps, TSS was reduced to 74.8% so turbidity decrased reased until 31%. After reverse osmosis process, BOD, and COD decreased more than 99%, and there was no amino acids detected in permeate stream. Factors that affect performance of reverse osmosis were transmembrane pressure, temperature and pH. The higher transmembrane pressure, temperature and pH resulted the higher the flux permeate. The use of higher temperature make flux increasing, eventually increasing transmembrane pressure make the flux increased only at transmembrane pressure less than 716 kPa. The protein rejection was influenced unsignifanctly by transmembrane pressure, temperature and pH. During concentrating flux declined exponentially by time function. At concentration factor 2.75 resulted 79% and 12% of increasing protein and NPN, respectively. The amino acids content can be increased 2−23 times of the origin. Even arginin and sistin, the amino acids that were undetectable initially, but they can bedetected at concentration of 0.0360 and 0.0250 (w/v respectively at the end of the process. Hidrolysis and fermentation process can increase the amino acid content 31−45 times

  6. Performances of nanofiltration and low pressure reverse osmosis membranes for desalination: characterization and modelling

    Science.gov (United States)

    Boussouga, Y. A.; Lhassani, A.

    2017-03-01

    The nanofiltration and the reverse osmosis processes are the most common techniques for the desalination of water contaminated by an excess of salts. In this present study, we were interested in the characterization of commercial, composite and asymmetric membranes of nanofiltration (NF90, NF270) and low pressure reverse osmosis (BW30LE). The two types of characterization that we opted for our study: (i) characterization of electrical proprieties, in terms of the surface charge of various membranes studied by the measurement of the streaming potential, (ii) hydrodynamic characterization in terms of hydraulic permeability with pure water, mass transfer and phenomenological parameters for each system membrane/salt using hydrodynamic approaches. The irreversible thermodynamics allowed us to model the observed retention Robs of salts (NaCl and Na2SO4) for the different membranes studied, to understand and to predict a good filtration with a membrane. A study was conducted on the type of mass transfer for each system membrane/salt: convection and diffusion. The results showed that all tested membranes are negatively charged for the solutions at neutral pH, this is explained by their material composition. The results also showed competitiveness between the different types of membranes. In view of that the NF remains effective in terms of selective retention with less energy consumption than LPRO.

  7. Assessment of Silt Density Index (SDI) as Fouling Propensity Parameter in Reverse Osmosis Desalination

    KAUST Repository

    Rachman, Rinaldi

    2011-07-01

    Reverse osmosis operations are facing persistent fouling phenomenon that has challenged the integrity of these processes. Prediction of fouling potential by measuring a fouling index toward feed water is essential to ensure robust operation. Moreover, employing a reliable fouling index with good reproducibility and precision is necessary. Silt density index (SDI) is considered insufficient in terms of reliability and empirical theory, among other limitations. Nevertheless due its simplicity, SDI measurement is utilized extensively in RO desalination systems. The aim of this research is to assess the reliability of SDI. Methods include the investigation of different SDI membranes and study of the nature of the SDI filtration. Results demonstrate the existence of the membrane properties\\' variation within manufacturers, which then causes a lack of accuracy in fouling risk estimation. The nature of particles during SDI filtration provides information that particle concentration and size play a significant role on SDI quantification with substantial representation given by particles with size close to membrane nominal pore size. Moreover, turbidity assisted SDI measurements along with determination of UF pretreated and clean water fouling potential, establishes the indication of non-fouling related phenomena involved on SDI measurement such as a natural organic matter adsorption and hydrodynamic condition that alters during filtration. Additionally, it was found that the latter affects the sensitivity of SDI by being represented by some portions of SDI value. Keywords: Reverse Osmosis, Fouling index, Particulate Fouling, Silt Density Index (SDI), and Assessment of SDI.

  8. Study of applicability of a reverse osmosis system in the treatment of waste liquids (RAD-WASTE); Estudio de aplicabilidad de un sistema de osmosis inversa en el tratamiento de residuos liquidos (RAD-WASTE)

    Energy Technology Data Exchange (ETDEWEB)

    Hortiguela Martinez, R.; Ruiz Garcia, P.; Saiz Cuesta, A.

    2013-07-01

    Study of alternatives to the current system of water treatment line of soils of the refueling (evaporation followed by a demineralization with ion exchange resins), with a technique more respectful with the environment as it is reverse osmosis. This process removed the soluble salts through semi-permeable membranes. These membranes are permeable to water but impermeable to most ions.

  9. Experimentation with a reverse osmosis plant powered by renewable energies

    Energy Technology Data Exchange (ETDEWEB)

    Segura, L.; Gomez, A. [Las Palmas de Gran Canaria Univ., Las Palmas (Spain). Dept. of Process Engineering; Nuez, I. [Las Palmas de Gran Canaria Univ., Las Palmas (Spain). Dept. of Electronic and Automatic Engineering

    2006-07-01

    This paper described a set of tests conducted in a reverse osmosis plant powered by renewable energy sources. Variations on feed flow, reject flow, recovery and power consumption were investigated. The plant has a production of over 115 m{sup 3} per day. During the experiments, the plant was required to operate at variable loading conditions. An energy recovery system was then developed to operate effectively with the observed variable load conditions. The system was incorporated within the reject flow system and was comprised of a Pelton turbine matched to the axis of an asynchronous energy generator. The system was designed to avoid making changes to the actual hydraulic circuit of the plant. Recovery system failures did not necessitate plant stoppages during the testing period. Simulations conducted to assess the energy system showed that optimal performance of the plant was between 16 and 18 kW with a working pressure of between 57 to 67 bars. Results also suggested that installing the system in the evacuation brine line would maximize the use of kinetic energy. It was concluded that energy recovery systems are ideal for use in seawater installations where functioning pressure levels are high. 14 refs., 1 tab., 5 figs.

  10. Biofouling of reverse osmosis membranes: positively contributing factors of Sphingomonas.

    Science.gov (United States)

    Gutman, Jenia; Herzberg, Moshe; Walker, Sharon L

    2014-12-02

    In the present study, we investigate the possible contribution of Sphingomonas spp. glycosphingolipids (GSL) and its extracellular polymeric substances (EPS) to the initial colonization and development of biofilm bodies on reverse osmosis (RO) membranes. A combination of an RO cross-flow membrane lab unit, a quartz crystal microbalance with dissipation (QCM-D), and a rear stagnation point flow (RSPF) system with either model bacteria (Sphingomonas wittichii, Escherichia coli, and Pseudomonas aeruginosa) or vesicles made of the bacterial GSL or LPS was used. Results showed noticeable differences in the adhesion LPS versus GSL vesicles in the QCM-D, with the latter exhibiting 50% higher adhesion to polyamide coated crystals (mimicking an RO membrane surface). A similar trend was observed for EPS extracted from S. wittichii, when compared to the adhesion tendency of EPS extracted from P. aeruginosa. By applying the whole-cell approach in the RO lab unit, the cumulative impact of S. wittichii cells composing GSL and probably their EPS reduced the permeate flux during bacterial accumulation on the membrane surface. Experiments were conducted with the same amount of Sphingomonas spp. or Escherichia coli cells resulting in a two times greater flux decline in the presence of S. wittichii. The distinct effects of Sphingomonas spp. on RO membrane biofouling are likely a combination of GSL presence (known for enhancing adhesion when compared to non-GSL containing bacteria) and the EPS contributing to the overall strength of the biofilm matrix.

  11. Kinetic study of seawater reverse osmosis membrane fouling

    KAUST Repository

    Khan, Muhammad

    2013-10-01

    Reverse osmosis (RO) membrane fouling is not a static state but a dynamic phenomenon. The investigation of fouling kinetics and dynamics of change in the composition of the foulant mass is essential to elucidate the mechanism of fouling and foulant-foulant interactions. The aim of this work was to study at a lab scale the fouling process with an emphasis on the changes in the relative composition of foulant material as a function of operating time. Fouled membrane samples were collected at 8 h, and 1, 2, and 4 weeks on a lab-scale RO unit operated in recirculation mode. Foulant characterization was performed by CLSM, AFM, ATR-FTIR, pyrolysis GC-MS, and ICP-MS techniques. Moreover, measurement of active biomass and analysis of microbial diversity were performed by ATP analysis and DNA extraction, followed by pyro-sequencing, respectively. A progressive increase in the abundance of almost all the foulant species was observed, but their relative proportion changed over the age of the fouling layer. Microbial population in all the membrane samples was dominated by specific groups/species belonging to Proteobacteria and Actinobacteria phyla; however, similar to abiotic foulant, their relative abundance also changed with the biofilm age. © 2013 American Chemical Society.

  12. Evaluation of membrane bioreactor for advanced treatment of industrial wastewater and reverse osmosis pretreatment

    Science.gov (United States)

    2013-01-01

    The evaluation of a membrane bioreactor (MBR) for pretreatment of reverse osmosis (RO) in order to reuse and reclamation of industrial town wastewater treatment plant was investigated in this study. Performance of MBR effluent through water quality in term of parameters such as chemical oxygen demand (COD), total suspended solids (TSS), total nitrogen (TN) and total coliform (TC) were measured. Also Silt density index (SDI) was used as indicator for RO feed water. The results of this study demonstrated that MBR produce a high quality permeate water. Approximately 75%, 98%, 74% and 99.9% removal of COD, TSS, TN and TC were recorded, respectively. Also SDI of the permeate effluent from membrane was below 3 for most of the times. It means that pilot yield a high quality treated effluent from the membrane module which can be used as RO feed water. PMID:24355199

  13. Inorganic fouling control in reverse osmosis wastewater reclamation by purging carbon dioxide.

    Science.gov (United States)

    Shahid, Muhammad Kashif; Pyo, Minsu; Choi, Young-Gyun

    2017-04-21

    Inorganic fouling on the membrane surface is one of the major prevalent issues affecting the performance and cost of reverse osmosis system. Chemical dosage is a widely adopted method for the inhibition of inorganic scale on the membrane surface. In this study, CO2 was used to control inorganic scale formation on surface of reverse osmosis (RO) membrane in wastewater reclamation. The pH of influent could be lowered by purging CO2. It caused an increase in solubility of inorganic salts in water resulting in discharge of principle ions in concentrate stream. A pilot plant study was conducted with four different RO modules including control, with dosage of antiscalant, with purging CO2 and with co-addition of antiscalant and CO2. The effectiveness of CO2 purging was assessed on the basis of operational analysis, in-line analysis and morphological results. Ryznar stability index was used to determine the scaling potential of system. The examined data indicated that CO2 purging was successful to inhibit scale formation on the membrane surface. Moreover, CO2 was found more eco-friendly than antiscalant, as no by-products were generated in concentrate stream.

  14. Treatment of dairy effluent model solutions by nanofiltration and reverse osmosis

    Directory of Open Access Journals (Sweden)

    I. Kyrychuk

    2015-05-01

    Full Text Available Introduction. Dairy industry generates a large amount of wastewaters that have high concentrations and contain milk components. Membrane processes have been shown to be convenient for wastewater treatment recovering milk components present in wastewaters and producing treated water. Materials and methods. The experiments were carried out in an unstirred batch sell using nanofiltration membranes OPMN-P (ZAO STC “Vladipor”, Russian Federation and reverse osmosis membranes NanoRo, ZAO (“RM Nanotech”, Russian Federation. The model solutions of dairy effluents –diluted skim and whole milk were used. Results. The nanofiltration and reverse osmosis membranes showed the same permeate flux during the concentration of model solutions of dairy effluents. The reason of this was likely membrane fouling with feed components. The fouling indexes indicated the fouling factor that was higher for RO. The higher permeate quality was obtainedwith RO membranes. The NF permeate containing up to 0.4 g/L of lactose and 0.75 g/L of mineral salts can be discharged or after finishing trеatment (e.g. RO or other can be reused. The obtained NF and RO retentate corresponds to milk in composition and can be used for non-food applications or as feed supplement for animals. Conclusions.The studied RO and NF membranes can be used for concentration of dairy effluents at low pressure. They showed better performance and separation characteristics comparing with data of other membranes available in the literature.

  15. Economic Evaluation of a Hybrid Desalination System Combining Forward and Reverse Osmosis

    Science.gov (United States)

    Choi, Yongjun; Cho, Hyeongrak; Shin, Yonghyun; Jang, Yongsun; Lee, Sangho

    2015-01-01

    This study seeks to evaluate the performance and economic feasibility of the forward osmosis (FO)–reverse osmosis (RO) hybrid process; to propose a guideline by which this hybrid process might be more price-competitive in the field. A solution-diffusion model modified with film theory was applied to analyze the effects of concentration polarization, water, and salt transport coefficient on flux, recovery, seawater concentration, and treated wastewater of the FO process of an FO-RO hybrid system. A simple cost model was applied to analyze the effects of flux; recovery of the FO process; energy; and membrane cost on the FO-RO hybrid process. The simulation results showed that the water transport coefficient and internal concentration polarization resistance are very important factors that affect performance in the FO process; however; the effect of the salt transport coefficient does not seem to be large. It was also found that the flux and recovery of the FO process, the FO membrane, and the electricity cost are very important factors that influence the water cost of an FO-RO hybrid system. This hybrid system can be price-competitive with RO systems when its recovery rate is very high, the flux and the membrane cost of the FO are similar to those of the RO, and the electricity cost is expensive. The most important thing in commercializing the FO process is enhancing performance (e.g.; flux and the recovery of FO membranes). PMID:26729176

  16. Economic Evaluation of a Hybrid Desalination System Combining Forward and Reverse Osmosis

    Directory of Open Access Journals (Sweden)

    Yongjun Choi

    2015-12-01

    Full Text Available This study seeks to evaluate the performance and economic feasibility of the forward osmosis (FO–reverse osmosis (RO hybrid process; to propose a guideline by which this hybrid process might be more price-competitive in the field. A solution-diffusion model modified with film theory was applied to analyze the effects of concentration polarization, water, and salt transport coefficient on flux, recovery, seawater concentration, and treated wastewater of the FO process of an FO-RO hybrid system. A simple cost model was applied to analyze the effects of flux; recovery of the FO process; energy; and membrane cost on the FO-RO hybrid process. The simulation results showed that the water transport coefficient and internal concentration polarization resistance are very important factors that affect performance in the FO process; however; the effect of the salt transport coefficient does not seem to be large. It was also found that the flux and recovery of the FO process, the FO membrane, and the electricity cost are very important factors that influence the water cost of an FO-RO hybrid system. This hybrid system can be price-competitive with RO systems when its recovery rate is very high, the flux and the membrane cost of the FO are similar to those of the RO, and the electricity cost is expensive. The most important thing in commercializing the FO process is enhancing performance (e.g.; flux and the recovery of FO membranes.

  17. Economic Evaluation of a Hybrid Desalination System Combining Forward and Reverse Osmosis.

    Science.gov (United States)

    Choi, Yongjun; Cho, Hyeongrak; Shin, Yonghyun; Jang, Yongsun; Lee, Sangho

    2015-12-29

    This study seeks to evaluate the performance and economic feasibility of the forward osmosis (FO)-reverse osmosis (RO) hybrid process; to propose a guideline by which this hybrid process might be more price-competitive in the field. A solution-diffusion model modified with film theory was applied to analyze the effects of concentration polarization, water, and salt transport coefficient on flux, recovery, seawater concentration, and treated wastewater of the FO process of an FO-RO hybrid system. A simple cost model was applied to analyze the effects of flux; recovery of the FO process; energy; and membrane cost on the FO-RO hybrid process. The simulation results showed that the water transport coefficient and internal concentration polarization resistance are very important factors that affect performance in the FO process; however; the effect of the salt transport coefficient does not seem to be large. It was also found that the flux and recovery of the FO process, the FO membrane, and the electricity cost are very important factors that influence the water cost of an FO-RO hybrid system. This hybrid system can be price-competitive with RO systems when its recovery rate is very high, the flux and the membrane cost of the FO are similar to those of the RO, and the electricity cost is expensive. The most important thing in commercializing the FO process is enhancing performance (e.g.; flux and the recovery of FO membranes).

  18. Removal of fluoride and uranium by nanofiltration and reverse osmosis: a review.

    Science.gov (United States)

    Shen, Junjie; Schäfer, Andrea

    2014-12-01

    Inorganic contamination in drinking water, especially fluoride and uranium, has been recognized as a worldwide problem imposing a serious threat to human health. Among several treatment technologies applied for fluoride and uranium removal, nanofiltration (NF) and reverse osmosis (RO) have been studied extensively and proven to offer satisfactory results with high selectivity. In this review, a comprehensive summary and critical analysis of previous NF and RO applications on fluoride and uranium removal is presented. Fluoride retention is generally governed by size exclusion and charge interaction, while uranium retention is strongly affected by the speciation of uranium and size exclusion usually plays a predominant role for all species. Adsorption on the membrane occurs as some uranium species interact with membrane functional groups. The influence of operating conditions (pressure, crossflow velocity), water quality (concentration, solution pH), solute–solute interactions, membrane characteristics and membrane fouling on fluoride and uranium retention is critically reviewed.

  19. Effectiveness of Subsidies in Technology Adoption: A Case Study Involving Reverse Osmosis (RO Membrane Technology

    Directory of Open Access Journals (Sweden)

    Nur Laili

    2016-12-01

    Full Text Available Adoption of new technologies is a process that involves technological learning and penetration of new products into the market. Within the process of new technologies adoption, government usually intervened by providing incentives, in order to support the technology adoption to be succeed. This paper examines the effectiveness of incentives for the sustainability of reverse osmosis (RO membrane technology adoption. The study conducted through single case study on SWRO installation in Mandangin Island, East Java, Indonesia. Results of case study indentify the existence of government incentive in the form of direct subsidies to decrease the price of clean water. Although successful in reducing the price of water, but effectiveness of the subsidy on the sustainability of SWRO is still low, which is operates only 30% in a year. Further analysis shows that these subsidies actually be counter-productive to the sustainability of SWRO installation.

  20. Molecular Dynamics Study of Carbon Nanotubes/Polyamide Reverse Osmosis Membranes: Polymerization, Structure, and Hydration.

    Science.gov (United States)

    Araki, Takumi; Cruz-Silva, Rodolfo; Tejima, Syogo; Takeuchi, Kenji; Hayashi, Takuya; Inukai, Shigeki; Noguchi, Toru; Tanioka, Akihiko; Kawaguchi, Takeyuki; Terrones, Mauricio; Endo, Morinobu

    2015-11-11

    Carbon nanotubes/polyamide (PA) nanocomposite thin films have become very attractive as reverse osmosis (RO) membranes. In this work, we used molecular dynamics to simulate the influence of single walled carbon nanotubes (SWCNTs) in the polyamide molecular structure as a model case of a carbon nanotubes/polyamide nanocomposite RO membrane. It was found that the addition of SWCNTs decreases the pore size of the composite membrane and increases the Na and Cl ion rejection. Analysis of the radial distribution function of water confined in the pores of the membranes shows that SWCNT+PA nanocomposite membranes also exhibit smaller clusters of water molecules within the membrane, thus suggesting a dense membrane structure (SWCNT+PA composite membranes were 3.9% denser than bare PA). The results provide new insights into the fabrication of novel membranes reinforced with tubular structures for enhanced desalination performance.

  1. Methodological approaches to conducting pilot and proof tests on reverse-osmosis systems: Results of comparative studies

    Science.gov (United States)

    Panteleev, A. A.; Bobinkin, V. V.; Larionov, S. Yu.; Ryabchikov, B. E.; Smirnov, V. B.; Shapovalov, D. A.

    2017-10-01

    When designing large-scale water-treatment plants based on reverse-osmosis systems, it is proposed to conduct experimental-industrial or pilot tests for validated simulation of the operation of the equipment. It is shown that such tests allow establishing efficient operating conditions and characteristics of the plant under design. It is proposed to conduct pilot tests of the reverse-osmosis systems on pilot membrane plants (PMPs) and test membrane plants (TMPs). The results of a comparative experimental study of pilot and test membrane plants are exemplified by simulating the operating parameters of the membrane elements of an industrial plant. It is concluded that the reliability of the data obtained on the TMP may not be sufficient to design industrial water-treatment plants, while the PMPs are capable of providing reliable data that can be used for full-scale simulation of the operation of industrial reverse-osmosis systems. The test membrane plants allow simulation of the operating conditions of individual industrial plant systems; therefore, potential areas of their application are shown. A method for numerical calculation and experimental determination of the true selectivity and the salt passage are proposed. An expression has been derived that describes the functional dependence between the observed and true salt passage. The results of the experiments conducted on a test membrane plant to determine the true value of the salt passage of a reverse-osmosis membrane are exemplified by magnesium sulfate solution at different initial operating parameters. It is shown that the initial content of a particular solution component has a significant effect on the change in the true salt passage of the membrane.

  2. Use of simulated evaporation to assess the potential for scale formation during reverse osmosis desalination

    Science.gov (United States)

    Huff, G.F.

    2004-01-01

    The tendency of solutes in input water to precipitate efficiency lowering scale deposits on the membranes of reverse osmosis (RO) desalination systems is an important factor in determining the suitability of input water for desalination. Simulated input water evaporation can be used as a technique to quantitatively assess the potential for scale formation in RO desalination systems. The technique was demonstrated by simulating the increase in solute concentrations required to form calcite, gypsum, and amorphous silica scales at 25??C and 40??C from 23 desalination input waters taken from the literature. Simulation results could be used to quantitatively assess the potential of a given input water to form scale or to compare the potential of a number of input waters to form scale during RO desalination. Simulated evaporation of input waters cannot accurately predict the conditions under which scale will form owing to the effects of potentially stable supersaturated solutions, solution velocity, and residence time inside RO systems. However, the simulated scale-forming potential of proposed input waters could be compared with the simulated scale-forming potentials and actual scale-forming properties of input waters having documented operational histories in RO systems. This may provide a technique to estimate the actual performance and suitability of proposed input waters during RO.

  3. Forward osmosis :a new approach to water purification and desalination.

    Energy Technology Data Exchange (ETDEWEB)

    Miller, James Edward; Evans, Lindsey R.

    2006-07-01

    Fresh, potable water is an essential human need and thus looming water shortages threaten the world's peace and prosperity. Waste water, brackish water, and seawater have great potential to fill the coming requirements. Unfortunately, the ability to exploit these resources is currently limited in many parts of the world by both the cost of the energy and the investment in equipment required for purification/desalination. Forward (or direct) osmosis is an emerging process for dewatering aqueous streams that might one day help resolve this problem. In FO, water from one solution selectively passes through a membrane to a second solution based solely on the difference in the chemical potential (concentration) of the two solutions. The process is spontaneous, and can be accomplished with very little energy expenditure. Thus, FO can be used, in effect, to exchange one solute for a different solute, specifically chosen for its chemical or physical properties. For desalination applications, the salts in the feed stream could be exchanged for an osmotic agent specifically chosen for its ease of removal, e.g. by precipitation. This report summarizes work performed at Sandia National Laboratories in the area of FO and reviews the status of the technology for desalination applications. At its current state of development, FO will not replace reverse osmosis (RO) as the most favored desalination technology, particularly for routine waters. However, a future role for FO is not out of the question. The ability to treat waters with high solids content or fouling potential is particularly attractive. Although our analysis indicates that FO is not cost effective as a pretreatment for conventional BWRO, water scarcity will likely drive societies to recover potable water from increasingly marginal resources, for example gray water and then sewage. In this context, FO may be an attractive pretreatment alternative. To move the technology forward, continued improvement and

  4. Waste water regeneration technologies: the experience of a pilot plant using an MBR process and micro-ultrafiltration and reverse osmosis in the waste water treatment plant at Canals-Lucidol de Cre spins (Valencia, Spain); Tecnologias para la regeneracion de aguas residuales: experiencia con planta piloto mediante un proceso MBR y membranas de micro-ultrafiltracion y osmosis inversa en la EDAR de Canals-L' Alcudia de Crespins (Valencia)

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Muro, J. L.; Garcia Garcia, J. J.; Morenilla Martinez, J. J.; Bernacer Bonora, I.; Lloret Salinas, R.; Pascual Garrido, J.; Escribano Romero, F.; Zarzo Martinez, D.

    2006-07-01

    This article looks at membrane bioreactor (MBR) technology and the use of micro-ultrafiltration membranes systems for treating sewage prior to reverse osmosis to desalinate sewage plant affluent. MBR technology ensures stable effluent quality (it is not affected by problems of sedimentation of the biological sludge in the clarifier) and practical disinfecting of the sludge. Micro-ultra-filtration technologies, either as treatment prior to reverse osmosis, or as independent tertiary treatment systems, generally guarantee extremely demanding permeate characteristics: SDI15 < 3-fouling index-, absence of microbiological organisms, and cloudines < 1 NTU. (Author)

  5. Electrochemical treatment of iopromide under conditions of reverse osmosis concentrates--elucidation of the degradation pathway.

    Science.gov (United States)

    Lütke Eversloh, C; Henning, N; Schulz, M; Ternes, T A

    2014-01-01

    Application of reverse osmosis for the reuse of treated wastewater on the one hand offers a way to provide high quality effluent waters. On the other hand reverse osmosis concentrates exhibiting highly concentrated contaminants are produced simultaneously. Electrochemical treatment of those concentrates is regarded as one possible answer to the problem of their disposal into surface waters. Nevertheless, due to the diversity of direct and indirect degradation processes during electrolysis, special care has to be taken about the formation of toxic transformation products (TPs). In this study the electrochemical transformation of the X-ray contrast medium iopromide was investigated as a representative of biologically persistent compounds. For this purpose, anodic oxidation at boron doped diamond as well as cathodic reduction using a platinum electrode were considered. Kinetic analyses revealed a transformation of 100 μM iopromide with first order kinetic constants between 0.6 and 1.6 × 10(-4) s(-1) at the beginning and a subsequent increase of the reaction order due to the influence of secondary oxidants formed during electrolysis. Mineralization up to 96% was achieved after about 7.5 h. At shorter treatment times several oxidatively and reductively formed transformation products were detected, whereas deiodinated iopromide represented the major fraction. Nevertheless, the latter exhibited negligible toxicological relevance according to tests on vibrio fisheri. Additional experiments utilizing a divided cell setup enabled the elucidation of the transformation pathway, whereas emerging TPs could be identified by means of high resolution mass spectrometry and MS(n)-fragmentations. During electrolysis the iodine released from Iopromide was found to 90% as iodide and to 10% as iodate even in the open cell experiments, limiting the potential formation of toxic iodo-disinfection by-products. Chlorinated TPs were not found. Copyright © 2013. Published by Elsevier Ltd.

  6. Asymmetrical reverse vortex flow due to induced-charge electro-osmosis around carbon stacking structures

    Science.gov (United States)

    Sugioka, Hideyuki

    2011-05-01

    Broken symmetry of vortices due to induced-charge electro-osmosis (ICEO) around stacking structures is important for the generation of a large net flow in a microchannel. Following theoretical predictions in our previous study, we herein report experimental observations of asymmetrical reverse vortex flows around stacking structures of carbon posts with a large height (~110 μm) in water, prepared by the pyrolysis of a photoresist film in a reducing gas. Further, by the use of a coupled calculation method that considers boundary effects precisely, the experimental results, except for the problem of anomalous flow reversal, are successfully explained. That is, unlike previous predictions, the precise calculations here show that stacking structures accelerate a reverse flow rather than suppressing it for a microfluidic channel because of the deformation of electric fields near the stacking portions; these structures can also generate a large net flow theoretically in the direction opposite that of a previous prediction for a standard vortex flow. Furthermore, by solving the one-dimensional Poisson-Nernst-Plank (PNP) equations in the presence of ac electric fields, we find that the anomalous flow reversal occurs by the phase retardation between the induced diffuse charge and the tangential electric field. In addition, we successfully explain the nonlinearity of the flow velocity on the applied voltage by the PNP analysis. In the future, we expect to improve the pumping performance significantly by using stacking structures of conductive posts along with a low-cost process.

  7. A new class of draw solutions for minimizing reverse salt flux to improve forward osmosis desalination.

    Science.gov (United States)

    Nguyen, Hau Thi; Nguyen, Nguyen Cong; Chen, Shiao-Shing; Ngo, Huu Hao; Guo, Wenshan; Li, Chi-Wang

    2015-12-15

    The applications of forward osmosis (FO) have been hindered because of the lack of an optimal draw solution. The reverse salt flux from the draw solution not only reduces the water flux but also increases the cost of draw solute replenishment. Therefore, in this study, Tergitol NP7 and NP9 with a long straight carbon chain and low critical micelle concentration (CMC) were coupled with highly charged ethylenediaminetetraacetic acid (EDTA) as an innovative draw solution to minimize reverse salt diffusion in FO for the first time. The results showed that the lowest reverse salt flux of 0.067 GMH was observed when 0.1M EDTA-2Na coupled with 15mM NP7 was used as a draw solution and deionized water was used as a feed solution in FO mode (active layer facing with the feed solution). This is due to the hydrophobic interaction between the tails of NP7 and the FO membrane, thus creating layers on the membrane surface and constricting the FO membrane pores. Moreover, 1M EDTA-2Na coupled with 15mM NP7 is promising as an optimal draw solution for brackish water and sea water desalination. Average water fluxes of 7.68, 6.78, and 5.95 LMH were achieved when brackish water was used as a feed solution (5, 10, and 20g/L NaCl), and an average water flux of 3.81 LMH was achieved when sea water was used as a feed solution (35g/L NaCl). The diluted draw solution was recovered using a nanofiltration (NF-TS80) membrane with a high efficiency of 95% because of the high charge and large size of the draw solution. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: WATTS PREMIER M-SERIES M-15,000 REVERSE OSMOSIS TREATMENT SYSTEM

    Science.gov (United States)

    Verification testing of the Watts Premier M-Series M-15,000 RO Treatment System was conducted over a 31-day period from April 26, 2004, through May 26, 2004. This test was conducted at the Coachella Valley Water District (CVWD) Well 7802 in Thermal, California. The source water...

  9. REMOVAL OF CHEMICAL AND MICROBIAL CONTAMINANTS IN DRINKING WATER - WATTS PREMIER M-2400 POINT-OF-ENTRY REVERSE OSMOSIS DRINKINGWATER TREATMENT SYSTEM

    Science.gov (United States)

    The Watts Premier M-2400 POE RO Drinking Water Treatment System was tested at the NSF Drinking Water Treatment Systems Laboratory for removal of the viruses fr and MS2, the bacteria Brevundimonas diminuta, and chemicals aldicarb, benzene, cadmium, carbofuran, cesium, chl...

  10. Isotope and ion selectivity in reverse osmosis desalination: geochemical tracers for man-made freshwater.

    Science.gov (United States)

    Kloppmann, Wolfram; Vengosh, Avner; Guerrot, Catherine; Millot, Romain; Pankratov, Irena

    2008-07-01

    A systematic measurement of ions and 2H/1H, 7Li/6Li, 11B/10B, 18O/ 16O, and 87Sr/86Sr isotopes in feed-waters, permeates, and brines from commercial reverse osmosis (RO) desalination plants in Israel (Ashkelon, Eilat, and Nitzana) and Cyprus (Larnaca) reveals distinctive geochemical and isotopic fingerprints of fresh water generated from desalination of seawater (SWRO) and brackish water (BWRO). The degree of isotope fractionation during the passage of water and solutes through the RO membranes depends on the medium (solvent-water vs. solutes), chemical speciation of the solutes, their charge, and their mass difference. O, H, and Sr isotopes are not fractionated during the RO process. 7Li is preferentially rejected in low pH RO, and B isotope fractionation depends on the pH conditions. Under low pH conditions, B isotopes are not significantly fractionated, whereas at high pH, RO permeates are enriched by 20 per thousand in 11B due to selective rejection of borate ion and preferential permeation of 11B-enriched boric acid through the membrane. The specific geochemical and isotopic fingerprints of SWRO provide a unique tool for tracing "man-made" fresh water as an emerging recharge component of natural water resources.

  11. Integrated removal of inorganic contaminants from acid mine drainage using BOF slag, lime, soda ash and reverse osmosis (RO): Implication for the production of drinking water

    CSIR Research Space (South Africa)

    Masindi, Vhahangwele

    2017-06-01

    Full Text Available softeners will pro- duce water of drinking standard. Acknowledgements The authors wish to express their sincere gratitude to the Council for Scientific and Industrial research (CSIR), Tshwane University of Technology for providing lab space to execute... quality. As such, this study proved that the coupling of RO process to BOF slag and different softeners will produce water of drinking standard. Acknowledgements The authors wish to express their sincere gratitude to the Council for Scientific...

  12. A survey of structure characterization methods for ultrafiltration and reverse osmosis membranes

    NARCIS (Netherlands)

    Smolders, C.A.; Mulder, M.H.V.; van der Velden, P.M.

    1976-01-01

    Asymmetric membranes consist of a thin skin, which is permselective to certain molecules in solution, and a porous support, serving as a mechanical support layer and also as a transport layer for the permeate. Both in ultrafiltration and in hyperfiltration (reverse osmosis) asymmetric membranes are

  13. A Mechanistic Study of Arsenic (III) Rejection by Reverse Osmosis and Nanofiltration Membranes

    Science.gov (United States)

    Suzuki, Tasuma

    2009-01-01

    Reverse osmosis/nanofiltration (RO/NF) membranes are capable to provide an effective barrier for a wide range of contaminants (including disinfection by-products precursors) in a single treatment step. However, solute rejection mechanisms by RO/NF membranes are not well understood. The lack of mechanistic information arises from experimental…

  14. Fluidized beds as turbulence promoters in the concentration of food liquids by reverse osmosis

    NARCIS (Netherlands)

    de Boer, R.; Zomerman, J.J.; Hiddink, J.; Aufderheyde, J.; van Swaaij, Willibrordus Petrus Maria; Smolders, C.A.

    1980-01-01

    Fluidized beds offer a potential improvement of reverse osmosis processes for food liquids, less fouling of the membrane, and reduced energy consumption. Our experiments were concerned with tubular systems in which fluidized beds of glass, steel, and lead beads were used. Glass beads appeared to be

  15. Treatment using reverse osmosis of an effluent from stainless steel manufacture

    CSIR Research Space (South Africa)

    Schoeman, JJ

    1996-09-01

    Full Text Available Reverse osmosis (RO) and physical/chemical technology were evaluated for treatment of neutralized spent acid effluent (seepage) containing high concentration levels of TDS (7500mg/l), Ca (400 mg/l), Cr-V1 (42 mg/l), nitrate-nitrogen (827 mg...

  16. Particulate and organic matter fouling of seawater reverse osmosis systems : Characterization, modelling and applications

    NARCIS (Netherlands)

    Salinas Rodriguez, S.G.

    2011-01-01

    Particulate/colloidal and organic fouling in seawater reverse osmosis (SWRO) systems results in flux decline, higher energy costs, increased salt passage, increased cleaning frequency, and use of chemicals. In practice, indices like SDI and MFI are used to assess particulate fouling, but they are

  17. Quantitative biofouling diagnosis in full scale nanofiltration and reverse osmosis installations

    NARCIS (Netherlands)

    Vrouwenvelder, J.S.; Manolarakis, S.A.; van der Hoek, J.P.; van Paassen, J.A.M.; van der Meer, Walterus Gijsbertus Joseph; van Agtmaal, J.M.C.; Prummel, H.D.M.; Kruithof, J.C.; Loosdrecht, M.C.M.

    2008-01-01

    Biofilm accumulation in nanofiltration and reverse osmosis membrane elements results in a relative increase of normalised pressure drop (ΔNPD). However, an increase in ΔNPD is not exclusively linked to biofouling. In order to quantify biofouling, the biomass parameters adenosine triphosphate (ATP),

  18. Recovery of drinking water and valuable minerals from acid mine drainage using an integration of magnesite, lime, soda ash, CO(sub)2 and reverse osmosis treatment processes

    CSIR Research Space (South Africa)

    Masindi, Vhahangwele

    2017-08-01

    Full Text Available that drinking water, metals, gypsum, hydrated lime/limestone were recovered from the treatment process as valuable resources. This was confirmed by X-ray diffraction (XRD) and X-ray Fluorescence (XRF). Morphological properties of initial and recovered minerals...

  19. Integrated Disinfection By-Products Mixtures Research: Concentration by Reverse Osmosis Membrane Techniques of Disinfection By-Products from Water Disinfected by Chlorination and Ozonation/Postchlorination

    Science.gov (United States)

    To conduct the health-effect studies described in subsequent articles in this series, concentrated aqueous mixtures of disinfection by-products were required for the two water treatment trains described in the preceding article (Miltner et al., 2008). To accomplish this, the fini...

  20. Reverse osmosis plant maintenance and efficacy in chronic kidney disease endemic region in Sri Lanka.

    Science.gov (United States)

    Jayasumana, Channa; Ranasinghe, Omesh; Ranasinghe, Sachini; Siriwardhana, Imalka; Gunatilake, Sarath; Siribaddana, Sisira

    2016-11-01

    Chronic Interstitial Nephritis in Agricultural Communities (CINAC) causes major morbidity and mortality for farmers in North-Central province (NCP) of Sri Lanka. To prevent the CINAC, reverse osmosis (RO) plants are established to purify the water and reduce the exposure to possible nephrotoxins through drinking water. We assessed RO plant maintenance and efficacy in NCP. We have interviewed 10 RO plant operators on plant establishment, maintenance, usage and funding. We also measured total dissolved solids (TDS in ppm) to assess the efficacy of the RO process. Most RO plants were operated by community-based organizations. They provide clean and sustainable water source for many in the NCP for a nominal fee, which tends to be variable. The RO plant operators carry out RO plant maintenance. However, maintenance procedures and quality management practices tend to vary from an operator to another. RO process itself has the ability to lower the TDS of the water. On average, RO process reduces the TDS to 29 ppm. The RO process reduces the impurities in water available to many individuals within CINAC endemic regions. However, there variation in maintenance, quality management, and day-to-day care between operators can be a cause for concern. This variability can affect the quality of water produced by RO plant, its maintenance cost and lifespan. Thus, uniform regulation and training is needed to reduce cost of maintenance and increase the efficacy of RO plants.

  1. Evaluation of potential for reuse of industrial wastewater using metal-immobilized catalysts and reverse osmosis.

    Science.gov (United States)

    Choi, Jeongyun; Chung, Jinwook

    2015-04-01

    This report describes a novel technology of reusing the wastewater discharged from the display manufacturing industry through an advanced oxidation process (AOP) with a metal-immobilized catalyst and reverse osmosis (RO) in the pilot scale. The reclaimed water generated from the etching and cleaning processes in display manufacturing facilities was low-strength organic wastewater and was required to be recycled to secure a water source. For the reuse of reclaimed water to ultrapure water (UPW), a combination of solid-phase AOP and RO was implemented. The removal efficiency of TOC by solid-phase AOP and RO was 92%. Specifically, the optimal acid, pH, and H2O2 concentrations in the solid-phase AOP were determined. With regard to water quality and operating costs, the combination of solid-phase AOP and RO was superior to activated carbon/RO and ultraviolet AOP/anion polisher/coal carbon. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Technical feasibility of reuse of effluent generated from reverse osmosis system in a pharmaceutical plant

    Directory of Open Access Journals (Sweden)

    Bárbara de A. S. de Andrade

    2017-09-01

    Full Text Available Reuse reduces the consumption of freshwater supplies and the negative environmental impact caused by the discharge of industrial effluents. Some industries have already adopted this practice; however, no studies were found in the literature regarding this subject in the pharmaceutical industry. This work investigated the potential reuse of effluent (concentrate generated from the Reverse Osmosis/Electro-deionization System (RO/EDI that is used for the production of purified water in a Brazilian pharmaceutical plant. This industrial complex consumed about 200,000 m3 of water per year between 2012 and 2013 to produce one million of doses of vaccines, i.e., 2 L of water per dose of vaccine produced. During this period, the RO/EDI produced 27,000 m3 of purified water annually and generated 24,000 m3 of effluent (concentrate. This amount of effluent could be used to supply the production of industry steam (boilers and/or cold water (cooling towers that annually consumed an average of 12,000 m3 and 40,000 m3, respectively. The reuse of this effluent would result in a gross financial savings of 96,000 USD per year, excluding the costs of installation and control. From what has been researched in the literature, this work showed for the first time the possibility of reuse of effluent from RO/EDI System in the pharmaceutical industry.

  3. Apparatus, System, and Method for Forward Osmosis in Water Reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2013-01-03

    An apparatus, system, and method for desalinating water is presented. The invention relates to recovery of water from impaired water sources by using FO and seawater as draw solution (DS). The seawater becomes diluted over time and can be easily desalinated at very low pressures. Thus, a device consumes less energy when recovering water. The apparatus, system and method comprise an immersed forward osmosis cell.

  4. Feasibility Study for Reuse of Zarand Thermal Power Plant Wastewater Passed through Reverse Osmosis Process

    Directory of Open Access Journals (Sweden)

    Elham Rahmanpour Salmani

    2017-04-01

    Full Text Available Increased urbanization and industrialization have disturbed the balance between water demand and water supply. Thermal power plants are among the largest water consumers and wastewater producers, while wastewater reuse can deal with the both concerns. Effluents of thermal power plants contain various pollutants, so remediation is needed before any other usage. Assessment the efficacy of Reverse Osmosis (RO system in treatment of Zarand power plant wastewater for reuse was the aim of present work. Physical and chemical parameters including pH, temperature, turbidity, BOD, COD, chromium, sulphate, chloride, nitrate, and phosphate ions were determined in samples collected from three locations of power station: feed water, influent to RO, and effluent. Sampling was done in the first six months of 2012. Data was characterized using descriptive statistics and Excel software. The average performance of RO in the removal percent of turbidity, BOD, COD, chromium, sulphate, chloride, nitrate, and phosphate was 57.5, 14.5, 27.4, 28, 46, 26, 73, and 99% respectively. In spite of less satisfying values of efficiency, mean values of pH, turbidity, BOD, COD, chromium, chloride, nitrate, and phosphate measured in effluent passing through RO were 7.5, 0.14 NTU, 1.8, 2.83, 0.018, 320, 1.6, and 0.001 mg/l respectively, all in compliance with discharging or irrigation standards, while 704 mg/l of sulphate ions detected in effluent, were much higher than acceptable limits.

  5. Using nanocomposite materials technology to understand and control reverse osmosis membrane compaction

    KAUST Repository

    Pendergast, Mary Theresa M.

    2010-10-01

    Composite reverse osmosis (RO) membranes were formed by interfacial polymerization of polyamide thin films over pure polysulfone and nanocomposite-polysulfone support membranes. Nanocomposite support membranes were formed from amorphous non-porous silica and crystalline microporous zeolite nanoparticles. For each hand-cast membrane, water flux and NaCl rejection were monitored over time at two different applied pressures. Nanocomposite-polysulfone supported RO membranes generally had higher initial permeability and experienced less flux decline due to compaction than pure polysulfone supported membranes. In addition, observed salt rejection tended to increase as flux declined from compaction. Crosssectional SEM images verified significant reduction in thickness of pure polysulfone supports, whereas nanocomposites better resisted compaction due to enhanced mechanical stability imparted by the nanoparticles. A conceptual model was proposed to explain the mechanistic relationship between support membrane compaction and observed changes in water flux and salt rejection. As the support membrane compacts, skin layer pore constriction increased the effective path length for diffusion through the composite membranes, which reduced both water and salt permeability identically. However, experimental salt permeability tended to decline to a greater extent than water permeability; hence, the observed changes in flux and rejection might also be related to structural changes in the polyamide thin film. © 2010 Elsevier B.V. All rights reserved.

  6. Dynamic bacterial communities on reverse-osmosis membranes in a full-scale desalination plant.

    Science.gov (United States)

    Manes, C-L de O; West, N; Rapenne, S; Lebaron, P

    2011-01-01

    To better understand biofouling of seawater reverse osmosis (SWRO) membranes, bacterial diversity was characterized in the intake water, in subsequently pretreated water and on SWRO membranes from a full-scale desalination plant (FSDP) during a 9 month period. 16S rRNA gene fingerprinting and sequencing revealed that bacterial communities in the water samples and on the SWRO membranes were very different. For the different sampling dates, the bacterial diversity of the active and the total bacterial fractions of the water samples remained relatively stable over the sampling period whereas the bacterial community structure on the four SWRO membrane samples was significantly different. The richness and evenness of the SWRO membrane bacterial communities increased with usage time with an increase in the Shannon diversity index of 2.2 to 3.7. In the oldest SWRO membrane (330 days), no single operational taxonomic unit (OTU) dominated and the majority of the OTUs fell into the Alphaproteobacteria or the Planctomycetes. In striking contrast, a Betaproteobacteria OTU affiliated to the genus Ideonella was dominant and exclusively found in the membrane used for the shortest time (10 days). This suggests that bacteria belonging to this genus could be one of the primary colonizers of the SWRO membrane. Knowledge of the dominant bacterial species on SWRO membranes and their dynamics should help guide culture studies for physiological characterization of biofilm forming species.

  7. Vacancy profile in reverse osmosis membranes studied by positron annihilation lifetime measurements and molecular dynamics simulations

    Science.gov (United States)

    Shimazu, A.; Goto, H.; Shintani, T.; Hirose, M.; Suzuki, R.; Kobayashi, Y.

    2013-06-01

    The positron annihilation technique using a slow positron beam can be used for the study of the vacancy profiles in typical reverse osmosis (RO) membranes. In this study, the vacancy profile in the polyamide membrane that exhibits a high permselectivity between ions and water was studied using the positron annihilation technique and molecular dynamics simulations. Ortho-positronium (o-Ps) lifetimes in the surface region of the membranes were evaluated by using a slow positron beam. The diffusion behavior of Na+ and water in the polyamides was simulated by molecular dynamics (MD) methods using the TSUBAME2 supercomputer at the Tokyo Institute of Technology and discussed with the vacancy profile probed by the o-Ps. The results suggested that the large hydration size of Na+ compared to the vacancy size in the polyamides contributes to the increased diffusivity selectivity of water/Na+ that is related to the NaCl desalination performance of the membrane. Both the hydration size of the ions and the vacancy size appeared to be significant parameters to discuss the diffusivity selectivity of water/ions in typical polyamide membranes.

  8. Effects of DMSO and glycerol additives on the property of polyamide reverse osmosis membrane.

    Science.gov (United States)

    Wu, Fengjing; Liu, Xiaojuan; Au, Chaktong

    2016-10-01

    The polyamide reverse osmosis (RO) membranes were prepared through interfacial polymerization of m-phenylenediamine (MPD) and trimesoyl chloride (TMC). The use of dimethyl sulfoxide (DMSO) and glycerol as additives for the formation of thin-film composite (TFC) was investigated. We studied the effect of DMSO and glycerol addition on membrane property and RO performance. Microscopic morphology was examined by atomic force microscopy and scanning electron microscopy. The surface hydrophilicity was characterized on the basis of water contact angle and surface solid-liquid interfacial free energy (-ΔGSL). Water flux and salt rejection ability of the membranes prepared with or without the additives were evaluated by cross-flow RO tests. The results reveal that the addition of DMSO and glycerol strongly influences the property of the TFC RO membrane. Compared to the MPD/TMC membrane fabricated without DMSO and glycerol, the MPD/TMC/DMSO/glycerol membrane has a rougher surface and is more hydrophilic, showing smaller water contact angle and larger -ΔGSL value. Without decrease in salt rejection ability, the MPD/TMC/DMSO/glycerol membrane shows water flux significantly larger than that of the MPD/TMC membrane. The unique property of the MPD/TMC/DMSO/glycerol membrane is attributed to the cooperative effect of DMSO and glycerol on membrane structure during the interfacial polymerization process.

  9. Forward osmosis applied to evaporative cooling make-up water

    Energy Technology Data Exchange (ETDEWEB)

    Nicoll, Peter; Thompson, Neil; Gray, Victoria [Modern Water plc, Guildford (United Kingdom)

    2012-11-15

    Modern Water is in the process of developing a number of forward osmosis based technologies, ranging from desalination to power generation. This paper outlines the progress made to date on the development and commercial deployment of a forward osmosis based process for the production of evaporative cooling tower make-up water from impaired water sources, including seawater. Evaporative cooling requires significant amounts of good quality water to replace the water lost by evaporation, drift and blowdown. This water can be provided by conventional desalination processes or by the use of tertiary treated sewage effluent. The conventional processes are well documented and understood in terms of operation and power consumption. A new process has been successfully developed and demonstrated that provides make-up water directly, using a core platform 'forward osmosis' technology. This new technology shows significant promise in allowing various raw water sources, such as seawater, to be used directly in the forward osmosis step, thus releasing the use of scarce and valuable high grade water for other more important uses. The paper presents theoretical and operational results for the process, where it is shown that the process can produce make-up water at a fraction of the operational expenditure when compared to conventional processes, in particular regarding power consumption, which in some cases may be as low as 15 % compared to competing processes. Chemical additives to the cooling water (osmotic agent) are retained within the process, thus reducing their overall consumption. Furthermore the chemistry of the cooling water does not support the growth of Legionella pneumophila. Corrosion results are also reported. (orig.)

  10. Novel Fouling-Reducing Coatings for Ultrafiltration, Nanofiltration, and Reverse Osmosis Membranes

    Energy Technology Data Exchange (ETDEWEB)

    Benny Freeman

    2008-08-31

    Polymeric membranes could potentially be the most flexible and viable long-term strategy for treatment of produced water from oil and gas production. However, widespread use of membranes, including reverse osmosis (RO) membranes, for produced water purification is hindered due to fouling caused by the impurities present in the water. Fouling of RO membranes is likely caused by surface properties including roughness, hydrophilicity, and charge, so surface modification is the most widely considered approach to improve the fouling properties of current RO membranes. This project focuses on two main approaches to surface modification: coating and grafting. Hydrophilic coating and grafting materials based on poly(ethylene glycol) (PEG) are applied to commercial RO membranes manufactured by Dow FilmTec and GE. Crossflow filtration experiments are used to determine the fouling resistance of modified membranes, and compare their performance to that of unmodified commercial RO membranes. Grafting and coating are shown to be two alternative methods of producing modified membranes with improved fouling resistance.

  11. Autonomous low-temperature solar Rankine cycle system for reverse osmosis desalination

    Energy Technology Data Exchange (ETDEWEB)

    Manolakos, D.; Makris, G.; Papadakis, G.; Kyritsis, S. [Agricultural University of Athens (Greece). Dept. of Agricultural Engineering; Bouzianas, K. [Hellas Energy K. Bouzianas P. Moschovitis and Co., Athens (Greece)

    2004-07-01

    The research regards the development, application testing and performance evaluation of a low temperature solar organic Rankine cycle system for Reverse Osmosis (RO) desalination. Below is given a technical description of the system under development: Thermal energy produced by the solar array evaporates the working fluid (HFC- 134a) in the evaporator surface. The super-heated vapour is driven to the expanders where the generated mechanical work produced by the Rankine cycle drives the RO unit pumps (high pressure pump, cooling water pump, feed water pump) and circulating pump. The saturated vapour at the expanders' outlet is directed to the condenser and condensates. On the condenser surface, seawater is pre-heated and directed to the seawater reservoir. Seawater pre-heating is applied to increase the fresh water recovery ratio. The seawater tank is insulated. The use of seawater on the condenser surface decreases the temperature of ''Low Temperature Reservoir'' of Rankine cycle thus a better cycle efficiency is achieved. For the prototype system 240 m2 of vacuum tube solar collectors will be deployed. The evaporator and condenser capacity is estimated to be about 100 kW. For these systems' characteristics and considering a water recovery ratio of seawater RO desalination unit of 30%, the average yearly fresh water production is estimated at 1450 m3 (or 4 m3 daily). Specific innovations of the system are: Low temperature thermal sources can be exploited efficiently for fresh water production; solar energy is used indirectly and does not heat the seawater; the RO unit is driven by mechanical work produced from the process; the system condenser acts as sea water pre-heater and this serves a double purpose; (1) increase of feed water temperature implies higher fresh water production (2) decrease of temperature of ''low temperature reservoir'' of Rankine cycle implies higher cycle efficiencies. (orig.)

  12. Impact of reverse nutrient diffusion on membrane biofouling in fertilizer-drawn forward osmosis

    KAUST Repository

    Li, Sheng

    2017-05-31

    Biofouling in fertilizer-drawn forward osmosis (FDFO) for water reuse was investigated by spiking pure bacteria species Pseudomonas aeruginosa PAO1+GFP and using three different fertilizers KNO3, KCl and KH2PO4 as draw solutions. The performance of FO process for treating synthetic wastewater was assessed and their influence on the membrane fouling and in particular biofouling was evaluated relative to the type of different fertilizers used and their rates of reverse diffusion. FO performances using KNO3 as draw solute exhibited severer flux decline (63%) than when using KCl (45%) and KH2PO4 (30%). Membrane autopsy indicated that the mass of organic foulants and biomass on fouled membrane surface using KNO3 as draw solute (947.5mg/m2 biopolymers, 72µm biofilm thickness and 53.3mg/m2 adenosine triphosphate) were significantly higher than that using KCl (450mg/m2 biopolymers, 33µm biofilm thickness and 28.2mg/m2 ATP) and KH2PO4 (440mg/m2 biopolymers, 35µm biofilm thickness and 33.5mg/m2 ATP). This higher flux decline is likely related to the higher reverse diffusion of KNO3 (19.8g/m2/h) than KCl (5.1g/m2/h) and KH2PO4 (3.7g/m2/h). The reverse diffused potassium could promote the organics and bacterial adhesion on FO membrane via charge screening effect and compression of electrical double layer. Moreover, reverse diffused nitrate provided increased N:P nutrient ratio was favorable for the bacteria to grow on the feed side of the FO membrane.

  13. Analysis of a Wave-Powered, Reverse-Osmosis System and Its Economic Availability in the United States: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Yi-Hsiang [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jenne, Dale S [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-09

    A wave energy converter (WEC) system has the potential to convert the wave energy resource directly into the high-pressure flow that is needed by the desalination system to permeate saltwater through the reverse-osmosis membrane to generate clean water. In this study, a wave-to-water numerical model was developed to investigate the potential use of a wave-powered desalination system (WPDS) for water production in the United States. The model was developed by coupling a time-domain radiation-and-diffraction-method-based numerical tool (WEC-Sim) for predicting the hydrodynamic performance of WECs with a solution-diffusion model that was used to simulate the reverse-osmosis process. To evaluate the feasibility of the WPDS, the wave-to-water numerical model was applied to simulate a desalination system that used an oscillating surge WEC device to pump seawater through the system. The annual water production was estimated based on the wave resource at a reference site on the coast of northern California to investigate the potential cost of water in that area, where the cost of water and electricity is high compared to other regions. In the scenario evaluated, for a 100-unit utility-scale electricity-producing array, the estimated levelized cost of energy for these WECs is about 3-6 times the U.S.'s current, unsubsidized electricity rates. However, with clean water as an end product and by directly producing pressurized water with WECs, rather than electricity as an intermediary, it is presently only 12 percent greater than typical water cost in California. This study suggests that a WEC array that produces water may be a viable, near-term solution to the nation's water supply, and the niche application of the WPDS may also provide developers with new opportunities to further develop technologies that benefit both the electric and drinking water markets.

  14. Analysis of a Wave-Powered, Reverse-Osmosis System and its Economic Availability in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Yi-Hsiang [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jenne, Dale S [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-03

    A wave energy converter (WEC) system has the potential to convert the wave energy resource directly into the high-pressure flow that is needed by the desalination system to permeate saltwater through the reverse-osmosis membrane to generate clean water. In this study, a wave-to-water numerical model was developed to investigate the potential use of a wave-powered desalination system (WPDS) for water production in the United States. The model was developed by coupling a time-domain radiation-and-diffraction-method-based numerical tool (WEC-Sim) for predicting the hydrodynamic performance of WECs with a solution-diffusion model that was used to simulate the reverse-osmosis process. To evaluate the feasibility of the WPDS, the wave-to-water numerical model was applied to simulate a desalination system that used an oscillating surge WEC device to pump seawater through the system. The annual water production was estimated based on the wave resource at a reference site on the coast of northern California to investigate the potential cost of water in that area, where the cost of water and electricity is high compared to other regions. In the scenario evaluated, for a 100-unit utility-scale array, the estimated levelized cost of energy for these WECs is about 3-6 times the U.S.'s current, unsubsidized electricity rates. However, with clean water as an end product and by directly producing pressurized water with WECs, rather than electricity as an intermediary, it is presently only 12% greater than typical water cost in California. This study suggests that a WEC array that produces water may be a viable, near-term solution to the nation's water supply, and the niche application of the WPDS may also provide developers with new opportunities to further develop technologies that benefit both the electric and drinking water markets.

  15. In-situ Non-destructive Studies on Biofouling Processes in Reverse Osmosis Membrane Systems

    KAUST Repository

    Farhat, Nadia

    2016-12-01

    Reverse osmosis (RO) and nanofiltration (NF) membrane systems are high-pressure membrane filtration processes that can produce high quality drinking water. Biofouling, biofilm formation that exceeds a certain threshold, is a major problem in spiral wound RO and NF membrane systems resulting in a decline in membrane performance, produced water quality, and quantity. In practice, detection of biofouling is typically done indirectly through measurements of performance decline. Existing direct biofouling detection methods are mainly destructive, such as membrane autopsies, where biofilm samples can be contaminated, damaged and resulting in biofilm structural changes. The objective of this study was to test whether transparent luminescent planar oxygen sensing optodes, in combination with a simple imaging system, can be used for in-situ, non-destructive biofouling characterization. Aspects of the study were early detection of biofouling, biofilm spatial patterning in spacer filled channels, and the effect of feed cross-flow velocity, and feed flow temperature. Oxygen sensing optode imaging was found suitable for studying biofilm processes and gave detailed spatial and quantitative biofilm development information enabling better understanding of the biofouling development process. The outcome of this study attests the importance of in-situ, non-destructive imaging in acquiring detailed knowledge on biofilm development in membrane systems contributing to the development of effective biofouling control strategies.

  16. Removal of Crotamiton from Reverse Osmosis Concentrate by a TiO2/Zeolite Composite Sheet

    Directory of Open Access Journals (Sweden)

    Qun Xiang

    2017-07-01

    Full Text Available Reverse osmosis (RO concentrate from wastewater reuse facilities contains concentrated emerging pollutants, such as pharmaceuticals. In this research, a paper-like composite sheet consisting of titanium dioxide (TiO2 and zeolite was synthesized, and removal of the antipruritic agent crotamiton from RO concentrate was studied using the TiO2/zeolite composite sheet. The RO concentrate was obtained from a pilot-scale municipal secondary effluent reclamation plant. Effective immobilization of the two powders in the sheet made it easy to handle and to separate the photocatalyst and adsorbent from purified water. The TiO2/zeolite composite sheet showed excellent performance for crotamiton adsorption without obvious inhibition by other components in the RO concentrate. With ultraviolet irradiation, crotamiton was simultaneously removed through adsorption and photocatalysis. The photocatalytic decomposition of crotamiton in the RO concentrate was significantly inhibited by the water matrix at high initial crotamiton concentrations, whereas rapid decomposition was achieved at low initial crotamiton concentrations. The major degradation intermediates were also adsorbed by the composite sheet. This result provides a promising method of mitigating secondary pollution caused by the harmful intermediates produced during advanced oxidation processes. The cyclic use of the HSZ-385/P25 composite sheet indicated the feasibility of continuously removing crotamiton from RO concentrate.

  17. Biofilm Formation on Reverse Osmosis Membranes Is Initiated and Dominated by Sphingomonas spp.▿ †

    Science.gov (United States)

    Bereschenko, L. A.; Stams, A. J. M.; Euverink, G. J. W.; van Loosdrecht, M. C. M.

    2010-01-01

    The initial formation and spatiotemporal development of microbial biofilm layers on surfaces of new and clean reverse osmosis (RO) membranes and feed-side spacers were monitored in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The feed water of the RO system had been treated by the sequential application of coagulation, flocculation, sand filtration, ultrafiltration, and cartridge filtration processes. The design of the flow cells permitted the production of permeate under cross-flow conditions similar to those in spiral-wound RO membrane elements of the full-scale system. Membrane autopsies were done after 4, 8, 16, and 32 days of flow-cell operation. A combination of molecular (fluorescence in situ hybridization [FISH], denaturing gradient gel electrophoresis [DGGE], and cloning) and microscopic (field emission scanning electron, epifluorescence, and confocal laser scanning microscopy) techniques was applied to analyze the abundance, composition, architecture, and three-dimensional structure of biofilm communities. The results of the study point out the unique role of Sphingomonas spp. in the initial formation and subsequent maturation of biofilms on the RO membrane and feed-side spacer surfaces. PMID:20190090

  18. Role of extracellular polymeric substances (EPS) in biofouling of reverse osmosis membranes.

    Science.gov (United States)

    Herzberg, Moshe; Kang, Seoktae; Elimelech, Menachem

    2009-06-15

    This study elucidates the mechanisms by which extracellular polymeric substances (EPS) impact permeate water flux and salt rejection during biofouling of reverse osmosis (RO) membranes. RO fouling experiments were conducted with Pseudomonas aeruginosa PAO1, EPS extracted from PAO1 biofilms, and dead PAO1 cells fixed in formaldehyde. While a biofouling layer of dead bacterial cells decreases salt rejection and permeate flux by a biofilm-enhanced osmotic pressure mechanism, the EPS biofouling layer adversely impacts permeate flux by increasing the hydraulic resistance to permeate flow. During controlled fouling experiments with extracted EPS in a simulated wastewater solution, polysaccharides adsorbed on the RO membranes much more effectively than proteins (adsorption efficiencies of 61.2-88.7% and 11.6-12.4% for polysaccharides and proteins, respectively). Controlled fouling experiments with EPS in sodium chloride solutions supplemented with 0.5 mM calcium ions (total ionic strength of 15 mM) indicate that calcium increases the adsorption efficiency of polysaccharides and DNA by 2- and 3-fold, respectively. The increased adsorption of EPS onto the membrane resulted in a significant decrease in permeate water flux. Corroborating with these calcium effects, atomic force microscopy (AFM) measurements demonstrated that addition of calcium ions to the feed solution results in a marked increase in the adhesion forces between a carboxylated particle probe and the EPS layer. The increase in the interfacial adhesion forces is attributed to specific EPS-calcium interactions that play a major role in biofouling of RO membranes.

  19. Biofilm formation on reverse osmosis membranes is initiated and dominated by Sphingomonas spp.

    Science.gov (United States)

    Bereschenko, L A; Stams, A J M; Euverink, G J W; van Loosdrecht, M C M

    2010-04-01

    The initial formation and spatiotemporal development of microbial biofilm layers on surfaces of new and clean reverse osmosis (RO) membranes and feed-side spacers were monitored in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The feed water of the RO system had been treated by the sequential application of coagulation, flocculation, sand filtration, ultrafiltration, and cartridge filtration processes. The design of the flow cells permitted the production of permeate under cross-flow conditions similar to those in spiral-wound RO membrane elements of the full-scale system. Membrane autopsies were done after 4, 8, 16, and 32 days of flow-cell operation. A combination of molecular (fluorescence in situ hybridization [FISH], denaturing gradient gel electrophoresis [DGGE], and cloning) and microscopic (field emission scanning electron, epifluorescence, and confocal laser scanning microscopy) techniques was applied to analyze the abundance, composition, architecture, and three-dimensional structure of biofilm communities. The results of the study point out the unique role of Sphingomonas spp. in the initial formation and subsequent maturation of biofilms on the RO membrane and feed-side spacer surfaces.

  20. Reverse Osmosis Shifts Chloramine Speciation Causing Re-Formation of NDMA during Potable Reuse of Wastewater.

    Science.gov (United States)

    McCurry, Daniel L; Ishida, Kenneth P; Oelker, Gregg L; Mitch, William A

    2017-08-01

    UV-based advanced oxidation processes (AOPs) effectively degrade N-nitrosodimethylamine (NDMA) passing through reverse osmosis (RO) units within advanced treatment trains for the potable reuse of municipal wastewater. However, certain utilities have observed the re-formation of NDMA after the AOP from reactions between residual chloramines and NDMA precursors in the AOP product water. Using kinetic modeling and bench-scale RO experiments, we demonstrate that the low pH in the RO permeate (∼5.5) coupled with the effective rejection of NH4+ promotes conversion of the residual monochloramine (NH2Cl) in the permeate to dichloramine (NHCl2) via the reaction: 2 NH2Cl + H+ ↔ NHCl2 + NH4+. Dichloramine is the chloramine species known to react with NDMA precursors to form NDMA. After UV/AOP, utilities generally use lime or other techniques to increase the pH of the finished water to prevent distribution system corrosion. Modeling indicated that, while the increase in pH halts dichloramine formation, it converts amine-based NDMA precursors to their more reactive, neutral forms. With modeling, and experiments at both bench-scale and field-scale, we demonstrate that reducing the time interval between RO treatment and final pH adjustment can significantly reduce NDMA re-formation by minimizing the amount of dichloramine formed prior to reaching the final target pH.

  1. Reverse osmosis desalination of chitosan cross-linked graphene oxide/titania hybrid lamellar membranes.

    Science.gov (United States)

    Deng, Hui; Sun, Penzhan; Zhang, Yingjiu; Zhu, Hongwei

    2016-07-08

    With excellent mass transport properties, graphene oxide (GO)-based lamellar membranes are believed to have great potential in water desalination. In order to quantify whether GO-based membranes are indeed suitable for reverse osmosis (RO) desalination, three sub-micrometer thick GO-based lamellar membranes: GO-only, reduced GO (RGO)/titania (TO) nanosheets and RGO/TO/chitosan (CTS) are prepared, and their RO desalination performances are evaluated in a home-made RO test apparatus. The photoreduction of GO by TO improves the salt rejection, which increases slowly with the membrane thickness. The RGO/TO/CTS hybrid membranes exhibit higher rejection rates of only about 30% (greater than threefold improvement compared with a GO-only membrane) which is still inferior compared to other commercial RO membranes. The low rejection rates mainly arise from the pressure-induced weakening of the ion-GO interlayer interactions. Despite the advantages of simple, low-cost preparation, high permeability and selectivity of GO-based lamellar membranes, as the current desalination performances are not high enough to afford practical application, there still remains a great challenge to realize high performance separation membranes for water desalination applications.

  2. Membrane morphology and topology for fouling control in Reverse Osmosis filtration systems

    Science.gov (United States)

    Ling, Bowen; Battiato, Ilenia

    2017-11-01

    Reverse Osmosis Membrane (ROM) filtration systems are widely utilized in waste-water recovery, seawater desalination, landfill water treatment, etc. During filtration, the system performance is dramatically affected by membrane fouling which causes a significant decrease in permeate flux as well as an increase in the energy input required to operate the system. Design and optimization of ROM filtration systems aim at reducing membrane fouling by studying the coupling between membrane structure, local flow field and foulant adsorption patterns. Yet, current studies focus exclusively on oversimplified steady-state models that ignore any dynamic coupling between fluid flow and transport through the membrane. In this work, we develop a customized solver (SUMembraneFoam) under OpenFOAM to solve the transient equations. The simulation results not only predict macroscopic quantities (e.g. permeate flux, pressure drop, etc.) but also show an excellent agreement with the fouling patterns observed in experiments. It is observed that foulant deposition is strongly controlled by the local shear stress on the membrane, and channel morphology or membrane topology can be modified to control the shear stress distribution and reduce fouling. Finally, we identify optimal regimes for design.

  3. Calcium phosphate scaling during wastewater desalination on oligoamide surfaces mimicking reverse osmosis and nanofiltration membranes.

    Science.gov (United States)

    Rathinam, Karthik; Oren, Yoram; Petry, Winfried; Schwahn, Dietmar; Kasher, Roni

    2018-01-01

    Desalinated domestic wastewater is an indispensable water resource in arid regions; however, its recovery can be limited by calcium phosphate scaling and fouling of the membrane. Here we investigated calcium phosphate mineralization on oligoamide surfaces that mimics reverse osmosis (RO) and nanofiltration (NF) membrane surfaces. We used a solution that simulates desalination of secondary treated domestic wastewater effluents for calcium phosphate mineralization experiments with oligoamide-coated gold surfaces. Attenuated total reflection-Fourier transform infrared spectroscopy and energy dispersive spectrometry showed that calcium phosphate and carbonate precipitated on RO mimetic surfaces. The rate of precipitation on oligoamide sensors was monitored by a quartz crystal microbalance, showing that scaling was more intense on the RO than the NF mimetic surface and that excessive carboxyl functional groups on both surfaces promoted scaling. Filtration experiments of similar solutions with commercial membranes showed that scaling was more intense on the RO membranes than on the NF membranes, which supported the results obtained with the oligoamide model surfaces. The results of this study can be implemented in developing RO and NF membranes to prevent calcium phosphate scaling and consequently lower water-treatment costs of domestic wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Assessment of silt density index (SDI) as fouling propensity parameter in reverse osmosis (RO) desalination systems

    KAUST Repository

    Rachman, Rinaldi

    2013-01-01

    Due to its simplicity, silt density index (SDI) is extensively used in reverse osmosis systems despite its limitations in predicting membrane fouling. Employing a reliable fouling index with good reproducibility and precision is necessary. The aim of this investigation is to assess the reliability of SDI in order to understand the reasons for the low level of precision and accuracy. Different commercial SDI membranes and feed water quality were used in this study. Results showed the existence of membrane properties\\' variation within manufacturers, which then causes a lack of accuracy in fouling risk estimation. The nature of particles during SDI filtration provides information that particle concentration and size play a significant role in SDI quantification with substantial representation given by particles with size close to membrane nominal pore size. Moreover, turbidity-assisted SDI measurements along with determination of ultrafiltration permeate and clean water fouling potential, establish the indication of nonfouling-related phenomena involved on SDI measurement such as natural organic matter adsorption and hydrodynamic conditions that alters during filtration. Additionally, it was found that the latter affects the sensitivity of SDI by being represented by some portions of SDI values. © 2013 Desalination Publications.

  5. High permeability and salt rejection reverse osmosis by a zeolite nano-membrane.

    Science.gov (United States)

    Liu, Yilun; Chen, Xi

    2013-05-14

    The possibility of employing a zeolite nano-membrane for seawater desalination is studied using comprehensive molecular dynamics simulations. Two types of zeolite with different wetting properties, the hydrophilic FAU and hydrophobic MFI, are used as the reverse osmosis (RO) membrane. Both can reach nearly 100% rejection of salt ions, and when the membrane thickness is smaller than 3.5 nm, the permeability is about 2 × 10(-9) m Pa(-1) s(-1), which is two orders of magnitude higher than that of the commercial state-of-the-art RO membrane. The relation between the permeability and thickness of the zeolite membrane is studied through the pressure drop-flux dependence. The pressure drop is linearly dependent on the thickness of the zeolite membrane. As the thickness approaches nanoscale, the end effect of water molecules entering the zeolite membrane has apparent influence on the pressure drop. For the FAU membrane the hydrophilicity can assist the water molecules entering the nanopore with reduced pressure drop, while for the hydrophobic MFI zeolite additional pressure drop arises from the capillary resistance. In order to sustain the pressure drop during desalination, the nanoscale zeolite membrane should be placed on a porous substrate and the ratio of the thickness of the nano-membrane to the radius of the supporting pore in the substrate should be properly optimized.

  6. Use of horizontal subsurface flow constructed wetlands to treat reverse osmosis concentrate of rolling wastewater.

    Science.gov (United States)

    Xu, Jingcheng; Zhao, Gang; Huang, Xiangfeng; Guo, Haobo; Liu, Wei

    2017-03-04

    According to the characteristics of the reverse osmosis concentrate (ROC) generated from iron and steel company, we used three sets of parallel horizontal subsurface flow (HSF) constructed wetlands (CWs) with different plants and substrate layouts to treat the high-salinity wastewater. The plant growth and removal efficiencies under saline condition were evaluated. The evaluation was based entirely on routinely collected water quality data and the physical and chemical characteristics of the plants (Phragmites australis, Typha latifolia, Iris wilsonii, and Scirpus planiculmis). The principal parameters of concern in the effluent were chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP). The results showed that the CWs were able to remove COD, TN, and TP from ROC. S. planiculmis was not suitable for the treatment of high-saline wastewater. The sequence of metals accumulated in CW plants was K>Ca>Na>Mg>Zn>Cu. More than 70% of metals were accumulated in the aboveground of P. australis. The CW filled with gravel and manganese ore and planted with P. australis and T. latifolia had the best performance of pollutant removal, with average removal of 49.96%, 39.45%, and 72.01% for COD, TN, and TP, respectively. The effluent water quality met the regulation in China. These results suggested that HSF CW planted with P. australis and T. latifolia can be applied for ROC pollutants removal.

  7. Permeability and selectivity of reverse osmosis membranes: correlation to swelling revisited.

    Science.gov (United States)

    Dražević, Emil; Košutić, Krešimir; Freger, Viatcheslav

    2014-02-01

    Membrane swelling governs both rejection of solutes and permeability of polymeric membranes, however very few data have been available on swelling in water of salt-rejecting reverse osmosis (RO) membranes. This study assesses swelling, thickness and their relation to water permeability for four commercial polyamide (PA) RO membranes (SWC4+, ESPA1, XLE and BW30) using atomic force microscopy (AFM) and attenuated total reflection Fourier transform IR spectroscopy (ATR-FTIR). ATR-FTIR offered a significantly improved estimate of the actual barrier thickness of PA, given AFM is biased by porosity ("fluffy parts") or wiggling of the active layer or presence of a coating layer. Thus obtained intrinsic permeability (permeability times thickness) and selectivity of aromatic polyamides plotted versus swelling falls well on a general trend, along with previously reported data on several common materials showing RO and NF selectivity. The observed general trend may be rationalized by viewing the polymers as a random composite medium containing molecularly small pores. The results suggest that the combination of a rigid low dielectric matrix, limiting the pore size, with multiple hydrophilic H-bonding sites may be a common feature of RO/NF membranes, allowing both high permeability and selectivity. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  8. Reverse osmosis desalination of chitosan cross-linked graphene oxide/titania hybrid lamellar membranes

    Science.gov (United States)

    Deng, Hui; Sun, Penzhan; Zhang, Yingjiu; Zhu, Hongwei

    2016-07-01

    With excellent mass transport properties, graphene oxide (GO)-based lamellar membranes are believed to have great potential in water desalination. In order to quantify whether GO-based membranes are indeed suitable for reverse osmosis (RO) desalination, three sub-micrometer thick GO-based lamellar membranes: GO-only, reduced GO (RGO)/titania (TO) nanosheets and RGO/TO/chitosan (CTS) are prepared, and their RO desalination performances are evaluated in a home-made RO test apparatus. The photoreduction of GO by TO improves the salt rejection, which increases slowly with the membrane thickness. The RGO/TO/CTS hybrid membranes exhibit higher rejection rates of only about 30% (greater than threefold improvement compared with a GO-only membrane) which is still inferior compared to other commercial RO membranes. The low rejection rates mainly arise from the pressure-induced weakening of the ion-GO interlayer interactions. Despite the advantages of simple, low-cost preparation, high permeability and selectivity of GO-based lamellar membranes, as the current desalination performances are not high enough to afford practical application, there still remains a great challenge to realize high performance separation membranes for water desalination applications.

  9. On a novel strategy for water recovery and recirculation in biorefineries through application of forward osmosis membranes

    DEFF Research Database (Denmark)

    Kalafatakis, Stavros; Braekevelt, Sylvie; Carlsen, Vilhelmsen

    2017-01-01

    and financial benefits of this technology can be undermined from the fact that FO should be usually coupled with reverse osmosis (RO) for subsequent water purification and draw solution regeneration. Hence, a different approach was applied in order to omit the RO step. Crude glycerol and enzymatically...... pretreated wheat straw, which are common 2nd generation biorefinery feedstocks, have been evaluated as possible draw solution. In this way, water can be directly recovered and transferred back into the fermentation loop without further purification. Applying the Aquaporin InsideTM Forward Osmosis system......A great amount of research has been performed during the last 10 years focusing on forward osmosis (FO)processes. The main driving force is to find an effective and low energy demanding methodology for water recovery as well as up-concentration of valuable products. Nevertheless, the energetic...

  10. Reverse osmosis molecular differentiation of organic liquids using carbon molecular sieve membranes

    Science.gov (United States)

    Koh, Dong-Yeun; McCool, Benjamin A.; Deckman, Harry W.; Lively, Ryan P.

    2016-08-01

    Liquid-phase separations of similarly sized organic molecules using membranes is a major challenge for energy-intensive industrial separation processes. We created free-standing carbon molecular sieve membranes that translate the advantages of reverse osmosis for aqueous separations to the separation of organic liquids. Polymer precursors were cross-linked with a one-pot technique that protected the porous morphology of the membranes from thermally induced structural rearrangement during carbonization. Permeation studies using benzene derivatives whose kinetic diameters differ by less than an angstrom show kinetically selective organic liquid reverse osmosis. Ratios of single-component fluxes for para- and ortho-xylene exceeding 25 were observed and para- and ortho- liquid mixtures were efficiently separated, with an equimolar feed enriched to 81 mole % para-xylene, without phase change and at ambient temperature.

  11. Reverse osmosis filtration for space mission wastewater: membrane properties and operating conditions

    Science.gov (United States)

    Lee, S.; Lueptow, R. M.

    2001-01-01

    Reverse osmosis (RO) is a compact process that has potential for the removal of ionic and organic pollutants for recycling space mission wastewater. Seven candidate RO membranes were compared using a batch stirred cell to determine the membrane flux and the solute rejection for synthetic space mission wastewaters. Even though the urea molecule is larger than ions such as Na+, Cl-, and NH4+, the rejection of urea is lower. This indicates that the chemical interaction between solutes and the membrane is more important than the size exclusion effect. Low pressure reverse osmosis (LPRO) membranes appear to be most desirable because of their high permeate flux and rejection. Solute rejection is dependent on the shear rate, indicating the importance of concentration polarization. A simple transport model based on the solution-diffusion model incorporating concentration polarization is used to interpret the experimental results and predict rejection over a range of operating conditions. Grant numbers: NAG 9-1053.

  12. Fluidized beds as turbulence promoters in the concentration of food liquids by reverse osmosis

    OpenAIRE

    de Boer, R.; Zomerman, J.J.; Hiddink, J.; Aufderheyde, J.; van Swaaij, Willibrordus Petrus Maria; Smolders, C.A.

    1980-01-01

    Fluidized beds offer a potential improvement of reverse osmosis processes for food liquids, less fouling of the membrane, and reduced energy consumption. Our experiments were concerned with tubular systems in which fluidized beds of glass, steel, and lead beads were used. Glass beads appeared to be preferable, since they caused little damage to the membrane. Only with the larger glass beads (3 mm) did the membrane skin become corrugated, so that the rejection decreased. The permeate flux for ...

  13. Inability of Microorganisms To Degrade Cellulose Acetate Reverse-Osmosis Membranes †

    OpenAIRE

    Ho, Leighton C. W.; Martin, David D.; Lindemann, William C.

    1983-01-01

    Operational cellulose acetate reverse-osmosis membranes were examined for evidence of biological degradation. Numerous fungi and bacteria were isolated by direct and enrichment techniques. When tested, most of the fungi were active cellulose degraders, but none of the bacteria were. Neither fungi nor bacteria were able to degrade cellulose acetate membrane in vitro, although many fungi were able to degrade cellulose acetate membrane after it had been deacetylated. Organisms did not significan...

  14. Composition and Variability of Biofouling Organisms in Seawater Reverse Osmosis Desalination Plants ▿ †

    OpenAIRE

    Zhang, Minglu; Jiang, Sunny; Tanuwidjaja, Dian; Voutchkov, Nikolay; Hoek, Eric M. V.; Cai, Baoli

    2011-01-01

    Seawater reverse osmosis (SWRO) membrane biofouling remains a common challenge in the desalination industry, but the marine bacterial community that causes membrane fouling is poorly understood. Microbial communities at different stages of treatment processes (intake, cartridge filtration, and SWRO) of a desalination pilot plant were examined by both culture-based and culture-independent approaches. Bacterial isolates were identified to match the genera Shewanella, Alteromonas, Vibrio, and Ce...

  15. Particulate and organic matter fouling of seawater reverse osmosis systems: Characterization, modelling and applications

    OpenAIRE

    Salinas Rodriguez, S.G.

    2011-01-01

    Particulate/colloidal and organic fouling in seawater reverse osmosis (SWRO) systems results in flux decline, higher energy costs, increased salt passage, increased cleaning frequency, and use of chemicals. In practice, indices like SDI and MFI are used to assess particulate fouling, but they are performed at very high initial flux (> 1500 L/m2-h) and do not take into account the deposition of particles/colloids in RO systems. In this study, the Modified Fouling Index with ultrafiltration mem...

  16. AN ESTIMATE OF THE DETENTION IN THE PROCESS OF REVERSE OSMOSIS SEPARATION BIOLOGICAL SOLUTIONS BIOCHEMICAL INDUSTRIES

    Directory of Open Access Journals (Sweden)

    S. I. Lazarev

    2015-01-01

    Full Text Available Retained on a membrane solute in reverse osmosis separation of biological fluids at the surface of the membrane gradually accumulates and forms a boundary layer, where its concentration is higher than in the bulk. Increased concentration of solute in the solution at the membrane surface causes a diffusive flow of solids from the membrane surface into the bulk solution. After some time in the system t is a stationary state. A convective flow of solute to the membrane surface will be balanced by the sum of the fluxes of solute through the membrane and from the membrane surface into the bulk solution, i.e. in the case of concentration polarization is formed an edge of the diffusion layer. It is established that the concentration-polarization in reverse osmosis separation of the aqueous biological fluids biochemical production is influenced by the flow rate of solvent and the mass transfer coefficient. Experimental study allowed to characterize that by using the process of reverse osmosis can effectively divided, clear, and contaravati industrial solutions biochemical industries. Data at a rate of detention allow to evaluate the influence of concentration polarization on the efficiency of the reverse osmosis separation of industrial solutions. As a result of systematization and evaluation of experimental data and dependencies at a rate of detention found that with increasing the concentration, the rate of detention of solutes decreases. Based on the analysis and modification of the proposed equation for theoretical calculation of detention. Theoretical description of the coefficient detention accurately adequately calculated the modified equation N. V. Churaev, B. V. Deryaguin and V. M. Starov. The numerical values of the empirical coefficients, to calculate and predict the odds of arrest for a similar membrane separation processes industrial solutions. Values obtained correlation coefficients. The correlation coefficients specify that the rate of

  17. Evaluation of New Reverse Osmosis Membranes for the Separation of Toxic Compounds from Wastewater

    Science.gov (United States)

    1976-06-01

    showed that sodium perborate , EDTA and BIZ flushes all restored the flux to 80-85% of the initial values. Each additive qave approximately equal results...separation of organic compounds using a simple test with sodium chloride solution. In addition, exploratory work was conducted on the potential application of...Reverse Osmosis 74 20 Performance of NS-1O0 Membranes when Tested with 500 ppm Sodium Chloride Solution at 600 psig and 250C 82 21 Removal of Isomers of

  18. Designing cost-effective seawater reverse osmosis system under optimal energy options

    Energy Technology Data Exchange (ETDEWEB)

    Gilau, Asmerom M.; Small, Mitchell J. [Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States)

    2008-04-15

    Today, three billion people around the world have no access to clean drinking water and about 1.76 billion people live in areas already facing a high degree of water stress. This paper analyzes the cost-effectiveness of a stand alone small-scale renewable energy-powered seawater reverse osmosis (SWRO) system for developing countries. In this paper, we have introduced a new methodology; an energy optimization model which simulates hourly power production from renewable energy sources. Applying the model using the wind and solar radiation conditions for Eritrea, East Africa, we have computed hourly water production for a two-stage SWRO system with a capacity of 35 m{sup 3}/day. According to our results, specific energy consumption is about 2.33 kW h/m{sup 3}, which is a lower value than that achieved in most of the previous designs. The use of a booster pump, energy recovery turbine and an appropriate membrane, allows the specific energy consumption to be decreased by about 70% compared to less efficient design without these features. The energy recovery turbine results in a reduction in the water cost of about 41%. Our results show that a wind-powered system is the least cost and a PV-powered system the most expensive, with finished water costs of about 0.50 and 1.00/m{sup 3}, respectively. By international standards, for example, in China, these values are considered economically feasible. Detailed simulations of the RO system design, energy options, and power, water, and life-cycle costs are presented. (author)

  19. High-performance multi-functional reverse osmosis membranes obtained by carbon nanotube·polyamide nanocomposite

    Science.gov (United States)

    Inukai, Shigeki; Cruz-Silva, Rodolfo; Ortiz-Medina, Josue; Morelos-Gomez, Aaron; Takeuchi, Kenji; Hayashi, Takuya; Tanioka, Akihiko; Araki, Takumi; Tejima, Syogo; Noguchi, Toru; Terrones, Mauricio; Endo, Morinobu

    2015-01-01

    Clean water obtained by desalinating sea water or by purifying wastewater, constitutes a major technological objective in the so-called water century. In this work, a high-performance reverse osmosis (RO) composite thin membrane using multi-walled carbon nanotubes (MWCNT) and aromatic polyamide (PA), was successfully prepared by interfacial polymerization. The effect of MWCNT on the chlorine resistance, antifouling and desalination performances of the nanocomposite membranes were studied. We found that a suitable amount of MWCNT in PA, 15.5 wt.%, not only improves the membrane performance in terms of flow and antifouling, but also inhibits the chlorine degradation on these membranes. Therefore, the present results clearly establish a solid foundation towards more efficient large-scale water desalination and other water treatment processes. PMID:26333385

  20. Concentration of pineapple juice by reverse osmosis: physicochemical characteristics and consumer acceptance

    Directory of Open Access Journals (Sweden)

    Daniel Simões Couto

    2011-12-01

    Full Text Available Reverse osmosis has been used for the concentration of fruit juices with promising considering the quality of the obtained products. The objective of this study was to concentrate single strength pineapple juice by reverse osmosis. The concentration was carried out with polyamide composite membranes in a 0.65 m² plate and frame module at 60 bar transmembrane pressure at 20 °C. The permeate flux was 17 L.hm-2. The total soluble solid content of the juice increased from 11 to 31 °Brix corresponding to a Volumetric Concentration Factor (VCF of 2.9. The concentration of soluble solids, total solids, and total acidity increased proportionally to FCV. The concentrated juice and three commercial concentrated pineapple juices were evaluated regarding preference and purchase intention by 79 pineapple juice consumers. The concentrated juice by reverse osmosis was the preferred among consumers. It can be concluded that this process may be considered an alternative to the pre-concentration of fruit juices.

  1. R. O. Kinetic, energy saver for desalination plants by reverse osmosis; R. O: Kinetic, sistema de ahorro de energia en las plantas de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Plasencia Rodriguez, J. P.

    2003-07-01

    The R. O. Kinetic is a novel system of energy saving, for desalination plants by reverse osmosis, based on the isobaric chambers. With this system it is able to obtain values of specific consumption of energy during the process, around 2, 1-2,2 kWh/m''3, reducing the operation cost of these facilities. (Author)

  2. Rejection of emerging organic micropollutants in nanofiltration-reverse osmosis membrane applications.

    Science.gov (United States)

    Xu, Pei; Drewes, Jörg E; Bellona, Christopher; Amy, Gary; Kim, Tae-Uk; Adam, Marc; Heberer, Thomas

    2005-01-01

    The rejection of emerging trace organics by a variety of commercial reverse osmosis (RO), nanofiltration (NF), and ultra-low-pressure RO (ULPRO) membranes was investigated using TFC-HR, NF-90, NF-200, TFC-SR2, and XLE spiral membrane elements (Koch Membrane Systems, Wilmington, Massachusetts) to simulate operational conditions for drinking-water treatment and wastewater reclamation. In general, the presence of effluent organic matter (EfOM) improved the rejection of ionic organics by tight NF and RO membranes, as compared to a type-II water matrix (adjusted by ionic strength and hardness), likely as a result of a decreased negatively charged membrane surface. Rejection of ionic pharmaceutical residues and pesticides exceeded 95% by NF-90, XLE, and TFC-HR membranes and was above 89% for the NF-200 membrane. Hydrophobic nonionic compounds, such as bromoform and chloroform, exhibited a high initial rejection, as a result of both hydrophobic-hydrophobic solute-membrane interactions and steric exclusion, but rejection decreased significantly after 10 hours of operation because of partitioning of solutes through the membranes. This resulted in a partial removal of disinfection byproducts by the RO membrane TFC-HR. In a type-II water matrix, the effect of increasing feed water recoveries on rejection of hydrophilic ionic and nonionic compounds was compound-dependent and not consistent for different membranes. The presence of EfOM, however, could neutralize the effect of hydrodynamic operating condition on rejection performance. The ULPRO and tight NF membranes were operated at lower feed pressure, as compared to the TFC-HR, and provided a product water quality similar to a conventional RO membrane, regarding trace organics of interest.

  3. Facile Modification of Reverse Osmosis Membranes by Surfactant-Assisted Acrylate Grafting for Enhanced Selectivity.

    Science.gov (United States)

    Baransi-Karkaby, Katie; Bass, Maria; Levchenko, Stanislav; Eitan, Shahar; Freger, Viatcheslav

    2017-02-21

    The top polyamide layer of composite reverse osmosis (RO) membranes has a fascinatingly complex structure, yet nanoscale nonuniformities inherently present in polyamide layer may reduce selectivity, e.g., for boron rejection. This study examines improving selectivity by in situ "caulking" such nonuniformities using concentration polarization-enhanced graft-polymerization with a surfactant added to the reactive solution. The surfactant appears to enhance both polarization (via monomer solubilization in surfactant micelles) and adherence of graft-polymer to the membrane surface, which facilitates grafting and reduces monomer consumption. The effect of surfactant was particularly notable for a hydrophobic monomer glycidyl methacrylate combined with a nonionic surfactant Triton X-100. With Triton added at an optimal level, close to critical micellization concentration (CMC), monomer gets solubilized and highly concentrated within micelles, which results in a significantly increased degree of grafting and uniformity of the coating compared to a procedure with no surfactant added. Notably, no improvement was obtained for an anionic surfactant SDS or the cationic surfactant DTAB, in which cases the high CMC of surfactant precludes high monomer concentration within micelles. The modification procedure was also up-scalable to membranes elements and resulted in elements with permeability comparable to commercial brackish water RO elements with superior boric acid rejection.

  4. A novel reverse osmosis membrane by ferrous sulfate assisted controlled oxidation of polyamide layer

    Science.gov (United States)

    Raval, Hiren D.; Raviya, Mayur R.; Gauswami, Maulik V.

    2017-11-01

    With growing desalination capacity, it is very important to evaluate the performance of thin film composite reverse osmosis (TFC RO) membrane in terms of energy consumption for desalination. There is a trade-off between salt rejection and water-flux of TFC RO membrane. This article presents a novel approach of analyzing the effect of mixture of an oxidizing agent sodium hypochlorite and a reducing agent ferrous sulfate on virgin TFC RO membrane. Experiments were carried out by varying the concentrations of both sodium hypochlorite and ferrous sulfate. The negative charge was induced on the membrane due to the treatment of combination of sodium hypochlorite and ferrous sulfate, thereby resulting in higher rejection of negative ions due to repulsive force. Membrane treated with 1000 mg l‑1 sodium hypochlorite and 2000 mg l‑1 ferrous sulfate showed the best salt rejection i.e. 96.23%. The characterization was carried out to understand the charge on the membrane surface by Zeta potential, morphology of membrane surface by scanning electron microscope (SEM), surface roughness features by atomic force microscope (AFM) and chemical structural changes by nuclear magnetic resonance (NMR) analysis.

  5. Extending the life-cycle of reverse osmosis membranes: A review.

    Science.gov (United States)

    Coutinho de Paula, Eduardo; Amaral, Míriam Cristina Santos

    2017-05-01

    The reverse osmosis (RO) technology for desalination and demineralization serves the global water crisis context, both technically and economically, and its market is growing. However, RO membranes have a limited life-cycle and are often disposed of in landfills. The impacts caused by the disposal of thousands of tonnes per annum of RO membranes have grown dramatically around the world. Waste prevention should have a high priority and take effect before the end-of-life phase of a product is reached. In this review, a summary is presented of the main advances in the performance of the RO technology and the membrane lifespan. Afterwards, this paper reviews the most important relevant literature and summarizes the key findings of the research on reusing and recycling the discarded modules for the purpose of extending the life-cycle of the RO membranes. In addtion, there are some recent researches that indicated recycling RO membranes for use by the microfiltration or ultrafiltration separation processes is a promising solution to the disposal problem. However, there are many gaps and differences in procedures and results. This article also discusses and brings to light key parameters involved and controversies about oxidative treatment of discarded RO membranes.

  6. Polishing Step Purification of High-Strength Wastewaters by Nanofiltration and Reverse Osmosis

    Directory of Open Access Journals (Sweden)

    Jinxiang Zhou

    2016-03-01

    Full Text Available This article reports findings on the use of nanofiltration (NF and reverse osmosis (RO for secondary treatment of high-strength rendering facility wastewaters following an ultrafiltration step. These wastewaters present significant challenges to classical treatment technologies. Constant-pressure, direct-flow membrane filtration experiments were done to screen for flux and effluent water permeate quality of ten commercial NF and RO membranes. All membranes tested were effective in reducing total dissolved salts (TDS and chemical oxygen demand (COD; however, only two membranes (Koch MPF-34 and Toray 70UB gave sufficiently stable flux values to warrant longer term cross-flow filtration studies. Cross-flow flux measurements, scanning electron microscopy (SEM, X-ray dispersive spectroscopy (EDS, and attenuated total reflectance-Fourier-transform infrared spectroscopy (ATR-FTIR indicated that both membranes were eventually fouled by organic and inorganic foulants; however, the Toray 70UB RO membrane yielded a capacity of 1600 L/m2 prior to cleaning. A preliminary economic analysis compared the estimated costs of energy and consumables for a dual-stage UF/RO membrane process and dissolved air floatation (DAF and found membrane process costs could be less than about 40% of the current DAF process.

  7. Reverse osmosis concentrate treatment by chemical oxidation and moving bed biofilm processes.

    Science.gov (United States)

    Vendramel, S M R; Justo, A; González, O; Sans, C; Esplugas, S

    2013-01-01

    In the present work, four oxidation techniques were investigated (O3, O3/UV, H2O2/O3, O3/H2O2/UV) to pre-treat reverse osmosis (RO) concentrate before treatment in a moving-bed biofilm reactor (MBBR) system. Without previous oxidation, the MBBR was able to remove a small fraction of the chemical oxygen demand (COD) (5-20%) and dissolved organic carbon (DOC) (2-15%). When the concentrate was previously submitted to oxidation, DOC removal efficiencies in the MBBR increased to 40-55%. All the tested oxidation techniques improved concentrate biodegradability. The concentrate treated by the combined process (oxidation and MBBR) presented residual DOC and COD in the ranges of 6-12 and 25-41 mg L(-1), respectively. Nitrification of the RO concentrate, pre-treated by oxidation, was observed in the MBBR. Ammonium removal was comprised between 54 and 79%. The results indicate that the MBBR was effective for the treatment of the RO concentrate, previously submitted to oxidation, generating water with an improved quality.

  8. Effect of flow velocity, substrate concentration and hydraulic cleaning on biofouling of reverse osmosis feed channels

    KAUST Repository

    Radu, Andrea I.

    2012-04-01

    A two-dimensional mathematical model coupling fluid dynamics, salt and substrate transport and biofilm development in time was used to investigate the effects of cross-flow velocity and substrate availability on biofouling in reverse osmosis (RO)/nanofiltration (NF) feed channels. Simulations performed in channels with or without spacer filaments describe how higher liquid velocities lead to less overall biomass amount in the channel by increasing the shear stress. In all studied cases at constant feed flow rate, biomass accumulation in the channel reached a steady state. Replicate simulation runs prove that the stochastic biomass attachment model does not affect the stationary biomass level achieved and has only a slight influence on the dynamics of biomass accumulation. Biofilm removal strategies based on velocity variations are evaluated. Numerical results indicate that sudden velocity increase could lead to biomass sloughing, followed however by biomass re-growth when returning to initial operating conditions. Simulations show particularities of substrate availability in membrane devices used for water treatment, e.g., the accumulation of rejected substrates at the membrane surface due to concentration polarization. Interestingly, with an increased biofilm thickness, the overall substrate consumption rate dominates over accumulation due to substrate concentration polarization, eventually leading to decreased substrate concentrations in the biofilm compared to bulk liquid. © 2012 Elsevier B.V.

  9. Coating of reverse osmosis membranes with amphiphilic copolymers for biofouling control

    KAUST Repository

    Bucs, Szilard

    2017-05-30

    Surface coating of membranes may be a promising option to control biofilm development and biofouling impact on membrane performance of spiral-wound reverse osmosis (RO) systems. The objective of this study was to investigate the impact of an amphiphilic copolymer coating on biofilm formation and biofouling control. The coating was composed of both hydrophilic and hydrophobic monomers hydroxyethyl methacrylate (HEMA) and perfluorodecyl acrylate (PFA), respectively. Commercial RO membranes were coated with HEMA-PFA copolymer film. Long and short term biofouling studies with coated and uncoated membranes and feed spacer were performed using membrane fouling simulators (MFSs) operated in parallel, fed with water containing nutrients. For the long-term studies pressure drop development in time was monitored and after eight days the MFSs were opened and the accumulated biofilm on the membrane and spacer sheets was quantified and characterized. The presence of the membrane coating was determined using X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). Results showed that the amphiphilic coating (i) delayed biofouling (a lower pressure drop increase by a factor of 3 and a lower accumulated active biomass amount by a factor of 6), (ii) influenced the biofilm composition (23% lower polysaccharides and 132% higher protein content) and (iii) was still completely present on the membrane at the end of the biofouling study, showing that the coating was strongly attached to the membrane surface. Using coated membranes and feed spacers in combination with advanced cleaning strategies may be a suitable way to control biofouling.

  10. Compositions and constituents of freshwater dissolved organic matter isolated by reverse osmosis.

    Science.gov (United States)

    Zhang, Yulong; Huang, Wen; Ran, Yong; Mao, Jingdong

    2014-08-15

    Dissolved organic matter (DOM) from riverine and lacustrine water was isolated using a reverse osmosis (RO) system. Solid-state (13)C nuclear magnetic resonance ((13)C NMR) was used to quantitatively evaluate the compositions and constituents of DOM, which are compared with previous investigations on marine DOM. Results indicated that concentration factor (CF) was a key metric controlling yield and sorption of DOM on the RO system. The sorption was likely non-selective, based on the (13)C NMR and δ(13)C analyses. Carbohydrates and lipids accounted for 25.0-41.5% and 30.2-46.3% of the identifiable DOM, followed by proteins (18.2-19.8%) and lignin (7.17-12.8%). The freshwater DOM contained much higher alkyl and aromatic C but lower alkoxyl and carboxyl C than marine DOM. The structural difference was not completely accounted for by using structure of high molecular weight (HMW) DOM, suggesting a size change involved in transformations of DOM during the transport from rivers to oceans. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Design and optimization of desalination reverse osmosis plants driven by renewable energies using genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Bourouni, K.; Ben M' Barek, T. [Energetique des Batiments et Systeme Solaire, Ecole Nationale d' Ingenieurs de Tunis, BP 37, Le Belvedere 1002 Tunis (Tunisia); Al Taee, A. [University of Surrey, Guidford, Surrey (United Kingdom)

    2011-03-15

    Renewable energy sources (RES) for powering desalination processes is a promising option especially in remote and arid regions where the use of conventional energy is costly or unavailable. Reverse Osmosis (RO) is one of the most suitable desalination processes to be coupled with different renewable energy sources such as solar and wind. If RES/RO systems are optimally designed, some combinations can be cost effective and reliable. However, the design of such systems is complex because of uncertain renewable energy supplies, load demands and the non-linear characteristics of some components. In such system, different scenarios can be suggested; i.e combinations of PV panels, type and number of batteries, type and number of turbines, etc. Therefore, it is difficult to determine the optimal configuration with classical techniques. The development of a tool to integrate all parameters involved and compare between the possible scenarios is very important. This paper presents a new model based on the Genetic Algorithms allowing the generation of several individuals (possible solutions) for coupling small RO unit to RES. A particular interest is focused on the hybrid systems (PV/WIND/Batteries/RO). The objective function to minimize corresponds to the total water cost (Capital cost plus Operational costs). Finally, a case study of PV/RO unit, installed since 2007 in Ksar Ghilene village in southern Tunisia, is presented. (author)

  12. Changes in physicochemical and transport properties of a reverse osmosis membrane exposed to chloraminated seawater

    KAUST Repository

    Valentino, Lauren

    2015-02-17

    This study contributed to improving our understanding of how disinfectants, applied to control biofouling of reverse osmosis (RO) membranes, result in membrane performance degradation. We investigated changes in physicochemical properties and permeation performance of a RO membrane with fully aromatic polyamide (PA) active layer. Membrane samples were exposed to varying concentrations of monochloramine, bromide, and iodide in both synthetic and natural seawater. Elemental analysis of the membrane active layer by Rutherford backscattering spectrometry (RBS) revealed the incorporation of bromine and iodine into the polyamide. The kinetics of polyamide bromination were first order with respect to the concentration of the secondary oxidizing agent Br2 for the conditions investigated. Halogenated membranes were characterized after treatment with a reducing agent and heavy ion probes to reveal the occurrence of irreversible ring halogenation and an increase in carboxylic groups, the latter produced as a result of amide bond cleavage. Finally, permeation experiments revealed increases in both water permeability and salt passage as a result of oxidative damage.

  13. Downstream processing of reverse osmosis brine: Characterisation of potential scaling compounds.

    Science.gov (United States)

    Zaman, Masuduz; Birkett, Greg; Pratt, Christopher; Stuart, Bruce; Pratt, Steven

    2015-09-01

    Reverse osmosis (RO) brine produced at a full-scale coal seam gas (CSG) water treatment facility was characterized with spectroscopic and other analytical techniques. A number of potential scalants including silica, calcium, magnesium, sulphates and carbonates, all of which were present in dissolved and non-dissolved forms, were characterized. The presence of spherical particles with a size range of 10-1000 nm and aggregates of 1-10 microns was confirmed by transmission electron microscopy (TEM). Those particulates contained the following metals in decreasing order: K, Si, Sr, Ca, B, Ba, Mg, P, and S. Characterization showed that nearly one-third of the total silicon in the brine was present in the particulates. Further, analysis of the RO brine suggested supersaturation and precipitation of metal carbonates and sulphates during the RO process should take place and could be responsible for subsequently capturing silica in the solid phase. However, the precipitation of crystalline carbonates and sulphates are complex. X-ray diffraction analysis did not confirm the presence of common calcium carbonates or sulphates but instead showed the presence of a suite of complex minerals, to which amorphous silica and/or silica rich compounds could have adhered. A filtration study showed that majority of the siliceous particles were less than 220 nm in size, but could still be potentially captured using a low molecular weight ultrafiltration membrane. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Effects of feed solution chemistry on low pressure reverse osmosis filtration of cesium and strontium.

    Science.gov (United States)

    Ding, Shiyuan; Yang, Yu; Huang, Haiou; Liu, Hengchen; Hou, Li-an

    2015-08-30

    The objective of this study was to identify the removal mechanisms of radionuclides by reverse osmosis (RO) membranes under conditions relevant to full-scale water treatment. For this purpose, the effects of feed solution chemistry on the removal of Cs and Sr by a low pressure RO system was investigated by systematically varying membrane surface charge, ionic composition, and organic matter concentrations. The results showed that the effects of solution chemistry on the filtration of Cs and Sr were related to their hydrated ionic radius, resulting in the predominance of the Donnan's effect and electrostatic interactions, respectively. Consequently, the rejection of Cs increased more pronouncedly than Sr with the increases of feed concentration. Due to the Donnan's effect, different anions decreased the rejection of Cs to different extents in accordance to the order of anions' radii as SO4(2-)>Cl(-)>NO3(-)>F(-). The variations in Sr rejection were influenced by the electrostatic interactions between Sr(2+) and the membrane. In addition, humic acid (HA) lowered the rejection of Cs and caused significant membrane flux decline, but did not change the rejection of Sr. Sr also aggravated HA fouling of the membrane. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Recycling of end-of-life reverse osmosis membranes by oxidative treatment: a technical evaluation.

    Science.gov (United States)

    Coutinho de Paula, Eduardo; Gomes, Júlia Célia Lima; Amaral, Míriam Cristina Santos

    2017-07-01

    The adverse impacts caused by the disposal of thousands of tonnes per annum of reverse osmosis (RO) membranes modules have grown dramatically around the world. The objective of this study was to evaluate the technical feasibility of recycling by chemical oxidation of end-of-life RO membranes for applications in other separation processes with specifications less rigorous. The recycling technique consisted in to cause a membrane exposition with oxidant solutions in order to remove its aromatic polyamide layer and subsequent conversion to a porous membrane. The recycling technique was evaluated by water permeability and salt rejection tests before and after the oxidative treatments. Initially, membranes' chemical cleaning and pretreatment procedures were assessed. Among factors evaluated, the oxidizing agent, its concentration and pH, associated with the oxidative treatment time, showed important influence on the oxidation of the membranes. Results showed that sodium hypochlorite and potassium permanganate are efficient agents for the membrane recycling. The great increased permeability and decreased salt rejection indicated changes on membranes' selective properties. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), atomic force microscopy (AFM), and contact angle characterization techniques revealed marked changes on the main membranes' physical-chemical properties, such as morphology, roughness and hydrophobicity. Reuse of produced effluents and fouling tendency of recycled membranes were also evaluated.

  16. Application of ceramic membranes for seawater reverse osmosis (SWRO) pre-treatment

    KAUST Repository

    Hamad, Juma

    2013-05-30

    Low-pressure (microfiltration/ultrafiltration (MF/UF)) membranes are being increasingly used as pre-treatment, prior to seawater reverse osmosis (SWRO). The objective of pre-treatment before reverse osmosis (RO) membranes is to remove undesirable and particulate fouling materials (algae, suspended and colloidal particles). Also, a pre-treatment barrier reduces organics and provides better feed water quality for RO membranes. MF and UF pre-treatment prior to SWRO provides Low Silt Density Index (SDI) values recommended for RO operation. Ceramic membranes are more attractive as they made of more chemically resistant materials, which allow for more stable operation and aggressive backwashing (BW) and cleaning. A pilot plant with a monolith ceramic MF membrane (0.1 μm pore size) from METAWATER was used to carry out the study. Red Sea water pumped from a distance of 700 m offshore from Thuwal (Kingdom of Saudi Arabia) was used as feed water. The pilot plant was operated automatically at constant flux of 150 LMH that involved BW, air flushing and forward flushing at the end of filtration cycle. Seawater permeates were used for hydraulic BW, while sodium hypochlorite, citric acid and sodium hydroxide were used for chemical cleaning (CIP) to restore the membrane permeability after use. Filtration cycles of 2.5 h were adopted for initial experiments. Aggressive BW flux of 1,800 LMH for 15 s, air flushing of 4 bars for 10 s and forward flushing of 300 LMH for 40 s were applied for regular membrane hydraulic cleaning. The increase of membrane resistances over time was monitored. Further studies were also performed by using Anopore ceramic membranes AAO100 (pore sizes of 0.1 μm) using a constant pressure bench-scale set-up. The feed water and permeate were analysed using an SDI unit, flow cytometre (FCM) and liquid chromatography with organic carbon detection (LC-OCD). The results showed that ceramic membrane filtration reduced the SDI15 of seawater from 6.1 to 2.1 which

  17. Removal of organic micro-pollutants (phenol, aniline and nitrobenzene) via forward osmosis (FO) process: Evaluation of FO as an alternative method to reverse osmosis (RO).

    Science.gov (United States)

    Cui, Yue; Liu, Xiang-Yang; Chung, Tai-Shung; Weber, Martin; Staudt, Claudia; Maletzko, Christian

    2016-03-15

    In this study, we have explored and compared the effectiveness of using (1) lab-fabricated forward osmosis (FO) membranes under both FO and reverse osmosis (RO) modes and (2) commercially available RO membranes under the RO mode for the removal of organic micro-pollutants. The lab-fabricated FO membranes are thin film composite (TFC) membranes consisting of a polyamide layer and a porous substrate cast from three different materials; namely, Matrimid, polyethersulfone (PESU) and sulfonated polyphenylene sulfone (sPPSU). The results show that the FO mode is superior to the RO mode in the removal of phenol, aniline and nitrobenzene from wastewater. The rejections of all three TFC membranes to all the three organic micro-pollutants under the FO processes are higher than 72% and can be even higher than 90% for aniline when a 1000 ppm aromatic aqueous solution and 1 M NaCl are employed as feeds. These performances outperform the results obtained from themselves and commercially available RO membranes under the RO mode. In addition, the rejection can be maintained even when treating a more concentrated feed solution (2000 ppm). The removal performance can be further enhanced by using a more concentrated draw solution (2 M). The water flux is almost doubled, and the rejection increment can reach up to 17%. Moreover, it was observed that annealing as a post-treatment would help compact the membrane selective layer and further enhance the separating efficiency. The obtained organic micro-pollutant rejections and water fluxes under various feasible operating conditions indicate that the FO process has potential to be a viable treatment for wastewater containing organic micro-pollutants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Removal of organic micro-pollutants (phenol, aniline and nitrobenzene) via forward osmosis (FO) process: Evaluation of FO as an alternative method to reverse osmosis (RO)

    KAUST Repository

    Cui, Yue

    2016-01-05

    In this study, we have explored and compared the effectiveness of using (1) lab-fabricated forward osmosis (FO) membranes under both FO and reverse osmosis (RO) modes and (2) commercially available RO membranes under the RO mode for the removal of organic micro-pollutants. The lab-fabricated FO membranes are thin film composite (TFC) membranes consisting of a polyamide layer and a porous substrate cast from three different materials; namely, Matrimid, polyethersulfone (PESU) and sulfonated polyphenylene sulfone (sPPSU). The results show that the FO mode is superior to the RO mode in the removal of phenol, aniline and nitrobenzene from wastewater. The rejections of all three TFC membranes to all the three organic micro-pollutants under the FO processes are higher than 72% and can be even higher than 90% for aniline when a 1000 ppm aromatic aqueous solution and 1 M NaCl are employed as feeds. These performances outperform the results obtained from themselves and commercially available RO membranes under the RO mode. In addition, the rejection can be maintained even when treating a more concentrated feed solution (2000 ppm). The removal performance can be further enhanced by using a more concentrated draw solution (2 M). The water flux is almost doubled, and the rejection increment can reach up to 17%. Moreover, it was observed that annealing as a post-treatment would help compact the membrane selective layer and further enhance the separating efficiency. The obtained organic micro-pollutant rejections and water fluxes under various feasible operating conditions indicate that the FO process has potential to be a viable treatment for wastewater containing organic micro-pollutants.

  19. Basic aspects of the use of reverse osmosis in indirect potable reuse; Aspectos basicos de la aplicacion de la osmosis inversa a la reutilizacion potable indirecta

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Ramirez, J. A.; Sales Marquez, D.; Quiroga Alonso, J. M.; Asano, T.

    2003-07-01

    Wastewater reclamation and reuse is an increasing activity in those countries who are facing water restrictions both in quality and quantity, and it has become an integral part of water resources management. Among several applications of reclaimed wastewater, one of the most interesting and innovative is indirect potable reuse. This consists in the purposeful augmentation of surface or groundwater resources with highly treated reclaimed water which will ultimately serve as a source of drinking water. There are world-wide experiences confirming that this kind of application is safe. The use of reverse osmosis for wastewater reclamation is very interesting and the use of this in indirect potable reuse started more that thirty years ago, mainly in USA. However the extension of this kind of applications is in someway low, not for economic issues or technology faults,but the ignorance, distrust or public opinion rejection. In this paper, the most important challenges, from a technical and scientific point of view, of indirect potable reuse are discussed to allow it to be used as a safe, reliable and additional water source: with all its implications and, of course, with all its benefits. (Author) 16 refs.

  20. Study of the effect of nanoparticles and surface morphology on reverse osmosis and nanofiltration membrane productivity.

    Science.gov (United States)

    Fang, Yuming; Duranceau, Steven J

    2013-08-15

    To evaluate the significance of reverse osmosis (RO) and nanofiltration (NF) surface morphology on membrane performance, productivity experiments were conducted using flat-sheet membranes and three different nanoparticles, which included SiO2, TiO2 and CeO2. In this study, the productivity rate was markedly influenced by membrane surface morphology. Atomic force microscopy (AFM) analysis of membrane surfaces revealed that the higher productivity decline rates associated with polyamide RO membranes as compared to that of a cellulose acetate NF membrane was due to the inherent ridge-and-valley morphology of the active layer. The unique polyamide active layer morphology was directly related to the surface roughness, and was found to contribute to particle accumulation in the valleys causing a higher flux decline than in smoother membranes. Extended RO productivity experiments using laboratory grade water and diluted pretreated seawater were conducted to compare the effect that different nanoparticles had on membrane active layers. Membrane flux decline was not affected by particle type when the feed water was laboratory grade water. On the other hand, membrane productivity was affected by particle type when pretreated diluted seawater served as feed water. It was found that CeO2 addition resulted in the least observable flux decline, followed by SiO2 and TiO2. A productivity simulation was conducted by fitting the monitored flux data into a cake growth rate model, where the model was modified using a finite difference method to incorporate surface thickness variation into the analysis. The ratio of cake growth term (k1) and particle back diffusion term (k2) was compared in between different RO and NF membranes. Results indicated that k2 was less significant for surfaces that exhibited a higher roughness. It was concluded that the valley areas of thin-film membrane surfaces have the ability to capture particles, limiting particle back diffusion.

  1. Study of the Effect of Nanoparticles and Surface Morphology on Reverse Osmosis and Nanofiltration Membrane Productivity

    Directory of Open Access Journals (Sweden)

    Steven J. Duranceau

    2013-08-01

    Full Text Available To evaluate the significance of reverse osmosis (RO and nanofiltration (NF surface morphology on membrane performance, productivity experiments were conducted using flat-sheet membranes and three different nanoparticles, which included SiO2, TiO2 and CeO2. In this study, the productivity rate was markedly influenced by membrane surface morphology. Atomic force microscopy (AFM analysis of membrane surfaces revealed that the higher productivity decline rates associated with polyamide RO membranes as compared to that of a cellulose acetate NF membrane was due to the inherent ridge-and-valley morphology of the active layer. The unique polyamide active layer morphology was directly related to the surface roughness, and was found to contribute to particle accumulation in the valleys causing a higher flux decline than in smoother membranes. Extended RO productivity experiments using laboratory grade water and diluted pretreated seawater were conducted to compare the effect that different nanoparticles had on membrane active layers. Membrane flux decline was not affected by particle type when the feed water was laboratory grade water. On the other hand, membrane productivity was affected by particle type when pretreated diluted seawater served as feed water. It was found that CeO2 addition resulted in the least observable flux decline, followed by SiO2 and TiO2. A productivity simulation was conducted by fitting the monitored flux data into a cake growth rate model, where the model was modified using a finite difference method to incorporate surface thickness variation into the analysis. The ratio of cake growth term (k1 and particle back diffusion term (k2 was compared in between different RO and NF membranes. Results indicated that k2 was less significant for surfaces that exhibited a higher roughness. It was concluded that the valley areas of thin-film membrane surfaces have the ability to capture particles, limiting particle back diffusion.

  2. Study of the Effect of Nanoparticles and Surface Morphology on Reverse Osmosis and Nanofiltration Membrane Productivity

    Science.gov (United States)

    Fang, Yuming; Duranceau, Steven J.

    2013-01-01

    To evaluate the significance of reverse osmosis (RO) and nanofiltration (NF) surface morphology on membrane performance, productivity experiments were conducted using flat-sheet membranes and three different nanoparticles, which included SiO2, TiO2 and CeO2. In this study, the productivity rate was markedly influenced by membrane surface morphology. Atomic force microscopy (AFM) analysis of membrane surfaces revealed that the higher productivity decline rates associated with polyamide RO membranes as compared to that of a cellulose acetate NF membrane was due to the inherent ridge-and-valley morphology of the active layer. The unique polyamide active layer morphology was directly related to the surface roughness, and was found to contribute to particle accumulation in the valleys causing a higher flux decline than in smoother membranes. Extended RO productivity experiments using laboratory grade water and diluted pretreated seawater were conducted to compare the effect that different nanoparticles had on membrane active layers. Membrane flux decline was not affected by particle type when the feed water was laboratory grade water. On the other hand, membrane productivity was affected by particle type when pretreated diluted seawater served as feed water. It was found that CeO2 addition resulted in the least observable flux decline, followed by SiO2 and TiO2. A productivity simulation was conducted by fitting the monitored flux data into a cake growth rate model, where the model was modified using a finite difference method to incorporate surface thickness variation into the analysis. The ratio of cake growth term (k1) and particle back diffusion term (k2) was compared in between different RO and NF membranes. Results indicated that k2 was less significant for surfaces that exhibited a higher roughness. It was concluded that the valley areas of thin-film membrane surfaces have the ability to capture particles, limiting particle back diffusion. PMID:24956946

  3. Organic Carbon Reduction in Seawater Reverse Osmosis (SWRO) Plants, Jeddah, Saudi Arabia

    KAUST Repository

    Alshahri, Abdullah

    2015-12-01

    Desalination is considered to be a major source of usable water in the Middle East, especially the Gulf countries which lack fresh water resources. A key and sometimes the only solution to produce high quality water in these countries is through the use of seawater reverse osmosis (SWRO) desalination technology. Membrane fouling is an economic and operational defect that impacts the performance of SWRO desalination technology. To limit this fouling phenomenon, it is important to implement the appropriate type of intake and pre-treatment system design. In this study, two types of systems were investigated, a vertical well system and a surface-water intake at a 9m depth. The purpose of this investigation is to study the impact of the different intake systems and pre-treatment stages in minimizing the concentrations of algae, bacteria, natural organic matter (NOM) and transparent exopolymer particles (TEP), in the feed water prior to pre-treatment, through the pre-treatment stages, and in the product water and concentrate. Water samples were collected from the surface seawater, the intakes (wells for site A, 9 m depth open ocean intake at site B), after the media filter, after the cartridge filter, and from the permeate and reject streams. The measured parameters included physical parameters, algae, bacteria, total organic carbon (TOC), fractions of dissolved NOM, particulate and colloidal TEP. The results of this study prove that the natural filtration and biological treatment of the seawater which occur in the aquifer matrix are very effective in improving the raw water quality to a significant degree. The results demonstrated that algae and biopolymers were 100% removed, the bacterial concentrations were significantly removed and roughly 50% or greater of TOC concentrations was eliminated by the aquifer matrix at site A. The aquifer feeding the vertical wells reduced TEP concentrations, but to differing degree. There is a slight decrease in the concentrations of

  4. Final Report: Computer Simulation of Osmosis and Reverse Osmosis in Structured Membranes

    Energy Technology Data Exchange (ETDEWEB)

    Sohail Murad

    2012-01-03

    Molecular simulation methods were developed as part of this project to increase our fundamental understanding of membrane based separation systems. Our simulations clarified for example that steric (size) effects had a significant impact on the desalination membranes. Previously it was thought the separation was entirely driven by coulombic force (attractive/repulsive forces at the membrane surfaces). Steric effects played an important role, because salt ions in brackish water are never present alone, but are strongly hydrated which effectively increases their size, and makes it impossible to enter a membrane, while the smaller water molecules can enter more readily. Membrane surface effects did play a role in increasing the flux of water, but not in the separation itself. In addition we also developed simulation methods to study ion exchange, gas separations, and pervaporation. The methods developed were used to once again increase our fundamental understanding of these separation processes. For example our studies showed that when the separation factor of gases in membranes can be significantly affected by the presence of another gas, it is generally because the separation mechanism has changed. For example in the case of nitrogen and carbon dioxide, in their pure state the separation factor is determined by diffusion, while in mixtures it is influenced more by adsorption in the membrane (zeolite in our case) Finally we developed a new technique using the NMR chemical shift to determine intermolecular interactions for mixtures. For polar-nonpolar systems such as Xe dissolved in water we were able to significantly improve the accuracy of gas solubilities, which are very sensitive to the cross interaction between water and Xe.

  5. Predicting the Specific Energy Consumption of Reverse Osmosis Desalination

    Directory of Open Access Journals (Sweden)

    Ashlynn S. Stillwell

    2016-12-01

    Full Text Available Desalination is often considered an approach for mitigating water stress. Despite the abundance of saline water worldwide, additional energy consumption and increased costs present barriers to widespread deployment of desalination as a municipal water supply. Specific energy consumption (SEC is a common measure of the energy use in desalination processes, and depends on many operational and water quality factors. We completed multiple linear regression and relative importance statistical analyses of factors affecting SEC using both small-scale meta-data and municipal-scale empirical data to predict the energy consumption of desalination. Statistically significant results show water quality and initial year of operations to be significant and important factors in estimating SEC, explaining over 80% of the variation in SEC. More recent initial year of operations, lower salinity raw water, and higher salinity product water accurately predict lower values of SEC. Economic analysis revealed a weak statistical relationship between SEC and cost of water production. Analysis of associated greenhouse gas (GHG emissions revealed important considerations of both electricity source and SEC in estimating the GHG-related sustainability of desalination. Results of our statistical analyses can aid decision-makers by predicting the SEC of desalination to a reasonable degree of accuracy with limited data.

  6. Biofouling in reverse and forward osmosis membrane systems

    NARCIS (Netherlands)

    Bucs, S.S.

    2017-01-01

    Global freshwater demand has significantly increased over the past century and continued growth is expected in the coming century. Since more than 97 percent of the water in the world is seawater, desalination technologies have the potential to solve the fresh water crisis. Currently, the most used

  7. Evaluation of contaminant removal of reverse osmosis and advanced oxidation in full-scale operation by combining passive sampling with chemical analysis and bioanalytical tools.

    Science.gov (United States)

    Escher, Beate I; Lawrence, Michael; Macova, Miroslava; Mueller, Jochen F; Poussade, Yvan; Robillot, Cedric; Roux, Annalie; Gernjak, Wolfgang

    2011-06-15

    Advanced water treatment of secondary treated effluent requires stringent quality control to achieve a water quality suitable for augmenting drinking water supplies. The removal of micropollutants such as pesticides, industrial chemicals, endocrine disrupting chemicals (EDC), pharmaceuticals, and personal care products (PPCP) is paramount. As the concentrations of individual contaminants are typically low, frequent analytical screening is both laborious and costly. We propose and validate an approach for continuous monitoring by applying passive sampling with Empore disks in vessels that were designed to slow down the water flow, and thus uptake kinetics, and ensure that the uptake is only marginally dependent on the chemicals' physicochemical properties over a relatively narrow molecular size range. This design not only assured integrative sampling over 27 days for a broad range of chemicals but also permitted the use of a suite of bioanalytical tools as sum parameters, representative of mixtures of chemicals with a common mode of toxic action. Bioassays proved to be more sensitive than chemical analysis to assess the removal of organic micropollutants by reverse osmosis, followed by UV/H₂O₂ treatment, as many individual compounds fell below the quantification limit of chemical analysis, yet still contributed to the observed mixture toxicity. Nonetheless in several cases, the responses in the bioassays were also below their quantification limits and therefore only three bioassays were evaluated here, representing nonspecific toxicity and two specific end points for estrogenicity and photosynthesis inhibition. Chemical analytical techniques were able to quantify 32 pesticides, 62 PCPPs, and 12 EDCs in reverse osmosis concentrate. However, these chemicals could explain only 1% of the nonspecific toxicity in the Microtox assay in the reverse osmosis concentrate and 0.0025% in the treated water. Likewise only 1% of the estrogenic effect in the E-SCREEN could be

  8. Surface modification of polyamide reverse osmosis membrane with organic-inorganic hybrid material for antifouling

    Science.gov (United States)

    Zhang, Yang; Wan, Ying; Pan, Guoyuan; Yan, Hao; Yao, Xuerong; Shi, Hongwei; Tang, Yujing; Wei, Xiangrong; Liu, Yiqun

    2018-03-01

    A series of thin-film composite reverse osmosis membranes based on polyamide have been modified by coating the polyvinyl alcohol and 3-mercaptopropyltriethoxysilane aqueous solution prepared by a sol-gel process on the membrane surface, followed by thermal crosslinking treatment. In order to improve the hydrophilicity of the modified TFC membranes, the membranes were then immersed into H2O2 aqueous solution to convert -SH into -SO3H. The resulting TFC membranes were characterized by SEM, AFM, ATR-FTIR, streaming potential, XPS as well as static contact angle. After surface modification with the organic-inorganic hybrid material, the TFC membranes show increased NaCl rejection and decreased water flux with increasing 3-mercaptopropyltrimethoxysilane content in coating solution. The optimal modification membrane (PA-SMPTES-0.8) exhibits a NaCl rejection of 99.29%, higher than that (97.20%) of the virgin PA membrane, and a comparable water flux to virgin PA membrane (41.7 L/m2 h vs 47.9 L/m2 h). More importantly, PA-SMPTES-0.8 membrane shows much more improved fouling resistance to BSA than virgin PA and PVA modified PA (PA-PVA-1.0) membranes. PA-SMPTES-0.8 membrane loses about 13% of the initial flux after BSA fouling for 12 h, which is lower than that of virgin PA and PA-PVA-1.0 membranes (42% and 18%). Furthermore, the flux recovery of PA-SMPTES-0.8 membrane reaches 94% after cleaning. Thus the TFC membranes modified by this organic-inorganic hybrid technology show potential applications as antifouling RO membrane for desalination and purification.

  9. Application of immersed MF (IMF) followed by reverse osmosis (RO) membrane for wastewater reclamation: A case study in Malaysia.

    Science.gov (United States)

    Ujang, Z; Ng, K S; Tg Hamzah, Tg Hazmin; Roger, P; Ismail, M R; Shahabudin, S M; Abdul Hamid, M H

    2007-01-01

    A pilot scale membrane plant was constructed and monitored in Shah Alam, Malaysia for municipal wastewater reclamation for industrial application purposes. The aim of this study was to verify its suitability under the local conditions and environmental constraints for secondary wastewater reclamation. Immersed-type crossflow microfiltration (IMF) was selected as the pretreatment step before reverse osmosis filtration. Secondary wastewater after chlorine contact tank was selected as feed water. The results indicated that the membrane system is capable of producing a filtrate meeting the requirements of both WHO drinking water standards and Malaysian Effluent Standard A. With the application of an automatic backwash process, IMF performed well in hydraulic performance with low fouling rate being achieved. The investigations showed also that chemical cleaning is still needed because of some irreversible fouling by microorganisms always remains. RO treatment with IMF pretreatment process was significantly applicable for wastewater reuse purposes and promised good hydraulic performance.

  10. Lyophilization and Reconstitution of Reverse Osmosis Concentrated Natural Organic Matter

    Science.gov (United States)

    Disinfection by-product (DBP) research can be complicated by difficulties in shipping large water quantities and changing natural organic matter (NOM) characteristics over time. To overcome these issues, it is advantageous to have a reliable method for concentrating and preservin...

  11. Controlling Biofouling in Seawater Reverse Osmosis Membrane Systems

    NARCIS (Netherlands)

    Dhakal, N.

    2017-01-01

    Seawater desalination is a rapidly growing coastal industry that is increasingly threatened by algal blooms. Depending on the severity of algal blooms, desalination systems may be forced to shut down because of clogging and/or poor feed water quality. To maintain stable operation and provide good

  12. Unlocking High-Salinity Desalination with Cascading Osmotically Mediated Reverse Osmosis: Energy and Operating Pressure Analysis.

    Science.gov (United States)

    Chen, Xi; Yip, Ngai Yin

    2018-02-20

    Current practice of using thermally driven methods to treat hypersaline brines is highly energy-intensive and costly. While conventional reverse osmosis (RO) is the most efficient desalination technique, it is confined to purifying seawater and lower salinity sources. Hydraulic pressure restrictions and elevated energy demand render RO unsuitable for high-salinity streams. Here, we propose an innovative cascading osmotically mediated reverse osmosis (COMRO) technology to overcome the limitations of conventional RO. The innovation utilizes the novel design of bilateral countercurrent reverse osmosis stages to depress the hydraulic pressure needed by lessening the osmotic pressure difference across the membrane, and simultaneously achieve energy savings. Instead of the 137 bar required by conventional RO to desalinate 70 000 ppm TDS hypersaline feed, the highest operating pressure in COMRO is only 68.3 bar (-50%). Furthermore, up to ≈17% energy saving is attained by COMRO (3.16 kWh/m 3 , compared to 3.79 kWh/m 3 with conventional RO). When COMRO is employed to boost the recovery of seawater desalination to 70% from the typical 35-50%, energy savings of up to ≈33% is achieved (2.11 kWh/m 3 , compared to 3.16 kWh/m 3 with conventional RO). Again, COMRO can operate at a moderate hydraulic pressure of 80 bar (25% lower than 113 bar of conventional RO). This study highlights the encouraging potential of energy-efficient COMRO to access unprecedented high recovery rates and treat hypersaline brines at moderate hydraulic pressures, thus extending the capabilities of membrane-based technologies for high-salinity desalination.

  13. Reverse osmosis influence over the content of metals and organic acids in low alcoholic beverages

    Directory of Open Access Journals (Sweden)

    Andrieş Mitică Tiberiu

    2017-01-01

    Full Text Available Wine is defined as an alcoholic beverage resulted from fermentation of grape must, having ethanol content higher than 8.5% (v/v. Wine consumption has health benefits related to the high concentration of polyphenolic compounds with antioxidant activity and cardiovascular protection effects. However, the alcohol content restricts wine consumption, but wines with low-alcohol content can be obtained with the help of the dealcoholisation process, after it was produced through alcoholic fermentation. The purpose of this work is to evaluate the organic acid concentration, metal content and other physical-chemical parameters of low alcoholic beverages obtained from grape must by a process which involves reverse osmosis, mixing in a variable ratio the permeate and concentrate and then fermentation. For the experiments, a Muscat Ottonel grape must from Iaşi vineyard was used. There were ten variants of beverages (wines with low alcoholic concentration, by mixing known quantities of the two phases resulting from the reverse osmosis process. These beverages (wines had an alcoholic concentration starting from 2.5% (v/v in the first variant, up to 7% (v/v in the tenth variant. Alcoholic concentration varies for each variant by 0.5% (v/v. After fermentation in 50 L stainless steel tanks, the samples were filtered with 0.45μm sterile membrane and bottled in 0.75 L glass bottles. After 2 months of storage at constant temperature, the beverage samples were analyzed to determine the metal content (AAS method, organic acids concentration (HPLC method, and other physical-chemical characteristics (OIV standard methods. The results obtained indicate that the very complex physical-chemical composition of the low alcoholic beverages analyzed is influenced by the specific chemical composition of a given grape must, as well as by the use of products obtained from reverse osmosis.

  14. Inland Treatment of the Brine Generated from Reverse Osmosis Advanced Membrane Wastewater Treatment Plant Using Epuvalisation System

    Science.gov (United States)

    Qurie, Mohannad; Abbadi, Jehad; Scrano, Laura; Mecca, Gennaro; Bufo, Sabino A.; Khamis, Mustafa; Karaman, Rafik

    2013-01-01

    The reverse osmosis (RO) brine generated from the Al-Quds University wastewater treatment plant was treated using an epuvalisation system. The advanced integrated wastewater treatment plant included an activated sludge unit, two consecutive ultrafiltration (UF) membrane filters (20 kD and 100 kD cutoffs) followed by an activated carbon filter and a reverse osmosis membrane. The epuvalisation system consisted of salt tolerant plants grown in hydroponic channels under continuous water flowing in a closed loop system, and placed in a greenhouse at Al-Quds University. Sweet basil (Ocimum basilicum) plants were selected, and underwent two consecutive hydroponic flowing stages using different brine-concentrations: an adaptation stage, in which a 1:1 mixture of brine and fresh water was used; followed by a functioning stage, with 100% brine. A control treatment using fresh water was included as well. The experiment started in April and ended in June (2012). At the end of the experiment, analysis of the effluent brine showed a remarkable decrease of electroconductivity (EC), PO43−, chemical oxygen demand (COD) and K+ with a reduction of 60%, 74%, 70%, and 60%, respectively, as compared to the influent. The effluent of the control treatment showed 50%, 63%, 46%, and 90% reduction for the same parameters as compared to the influent. Plant growth parameters (plant height, fresh and dry weight) showed no significant difference between fresh water and brine treatments. Obtained results suggest that the epuvalisation system is a promising technique for inland brine treatment with added benefits. The increasing of channel number or closed loop time is estimated for enhancing the treatment process and increasing the nutrient uptake. Nevertheless, the epuvalisation technique is considered to be simple, efficient and low cost for inland RO brine treatment. PMID:23823802

  15. Inland Treatment of the Brine Generated from Reverse Osmosis Advanced Membrane Wastewater Treatment Plant Using Epuvalisation System

    Directory of Open Access Journals (Sweden)

    Mohannad Qurie

    2013-07-01

    Full Text Available The reverse osmosis (RO brine generated from the Al-Quds University wastewater treatment plant was treated using an epuvalisation system. The advanced integrated wastewater treatment plant included an activated sludge unit, two consecutive ultrafiltration (UF membrane filters (20 kD and 100 kD cutoffs followed by an activated carbon filter and a reverse osmosis membrane. The epuvalisation system consisted of salt tolerant plants grown in hydroponic channels under continuous water flowing in a closed loop system, and placed in a greenhouse at Al-Quds University. Sweet basil (Ocimum basilicum plants were selected, and underwent two consecutive hydroponic flowing stages using different brine-concentrations: an adaptation stage, in which a 1:1 mixture of brine and fresh water was used; followed by a functioning stage, with 100% brine. A control treatment using fresh water was included as well. The experiment started in April and ended in June (2012. At the end of the experiment, analysis of the effluent brine showed a remarkable decrease of electroconductivity (EC, PO43−, chemical oxygen demand (COD and K+ with a reduction of 60%, 74%, 70%, and 60%, respectively, as compared to the influent. The effluent of the control treatment showed 50%, 63%, 46%, and 90% reduction for the same parameters as compared to the influent. Plant growth parameters (plant height, fresh and dry weight showed no significant difference between fresh water and brine treatments. Obtained results suggest that the epuvalisation system is a promising technique for inland brine treatment with added benefits. The increasing of channel number or closed loop time is estimated for enhancing the treatment process and increasing the nutrient uptake. Nevertheless, the epuvalisation technique is considered to be simple, efficient and low cost for inland RO brine treatment.

  16. Electrolysis-assisted mitigation of reverse solute flux in a three-chamber forward osmosis system.

    Science.gov (United States)

    Zou, Shiqiang; He, Zhen

    2017-05-15

    Forward osmosis (FO) has been widely studied for desalination or water recovery from wastewater, and one of its key challenges for practical applications is reverse solute flux (RSF). RSF can cause loss of draw solutes, salinity build-up and undesired contamination at the feed side. In this study, in-situ electrolysis was employed to mitigate RSF in a three-chamber FO system ("e-FO") with Na 2 SO 4 as a draw solute and deionized (DI) water as a feed. Operation parameters including applied voltage, membrane orientation and initial draw concentrations were systematically investigated to optimize the e-FO performance and reduce RSF. Applying a voltage of 1.5 V achieved a RSF of 6.78 ± 0.55 mmol m -2  h -1 and a specific RSF of 0.138 ± 0.011 g L -1 in the FO mode and with 1 M Na 2 SO 4 as the draw, rendering ∼57% reduction of solute leakage compared to the control without the applied voltage. The reduced RSF should be attributed to constrained ion migration induced by the coactions of electric dragging force (≥1.5 V) and high solute rejection of the FO membrane. Reducing the intensity of the solution recirculation from 60 to 10 mL min -1 significantly reduced specific energy consumption of the e-FO system from 0.693 ± 0.127 to 0.022 ± 0.004 kWh m -3 extracted water or from 1.103 ± 0.059 to 0.044 ± 0.002 kWh kg -1 reduced reversed solute. These results have demonstrated that the electrolysis-assisted RSF mitigation could be an energy-efficient method for controlling RSF towards sustainable FO applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Modelamento of osmosis system reverse set in motion by a photovoltaic generator; Modelamento de sistema de osmose reversa acionado por um gerador fotovoltaico

    Energy Technology Data Exchange (ETDEWEB)

    Fraidenraich, N.; Vilela, O. C.; Lima, G. A.

    2008-07-01

    A theoretical model to study the operational conditions of Reverse Osmosis systems (RO) is presented. The model is applied to simulate the behavior of a Photovoltaic-Powered Reverse Osmosis System (PV-RO) monitored with sensors for measuring water flow, salinity, pressure voltage and current of operation. the system is powered by a PV generator with peak power of 0.81 kW. The interface of the PV generator and the motor-pump is a frequency converter, programmed to maintain the array working at a fixed voltage, chosen within the region of the maximum power. Considering the relation given by the load curve (pressure vs. feed flow rate) the permeated flow rate was determined theoretically for a given membrane length. The deviation between calculated and experimental results is smaller than 14.5%. The model can be used to determine parameters important in the sizing of those systems. (Author)

  18. Fouling of Seawater Reverse Osmosis (SWRO) Membrane: Chemical and Microbiological Characterization

    KAUST Repository

    Khan, Muhammad T.

    2013-12-01

    In spite of abundant water resources, world is suffering from the scarcity of usable water. Seawater Reverse Osmosis (SWRO) desalination technology using polymeric membranes has been recognized as a key solution to water scarcity problem. However, economic sustainability of this advanced technology is adversely impacted by the membrane fouling problem. Fouling of RO membranes is a highly studied phenomenon. However, literature is found to be lacking a detailed study on kinetic and dynamic aspects of SWRO membrane fouling. The factors that impact the fouling dynamics, i.e., pretreatment and water quality were also not adequately studied at full–scale of operation. Our experimental protocol was designed to systematically explore these fouling aspects with the objective to improve the understanding of SWRO membrane fouling mechanisms. An approach with multiple analytical techniques was developed for fouling characterization. In addition to the fouling layer characterization, feed water quality was also analysed to assess its fouling potential. Study of SWRO membrane fouling dynamics and kinetics revealed variations in relative abundance of chemical and microbial constituents of the fouling layer, over operating time. Aromatic substances, most likely humic–like substances, were observed at relatively high abundance in the initial fouling layer, followed by progressive increase in relative abundances of proteins and polysaccharides. Microbial population grown on all membranes was dominated by specific groups/species belonging to different classes of Proteobacteria phylum; however, similar to abiotic foulant, their relative abundance also changed with the biofilm age and with the position of membrane element in RO vessel. Our results demonstrated that source water quality can significantly impact the RO membrane fouling scenarios. Moreover, the major role of chlorination in the SWRO membrane fouling was highlighted. It was found that intermittent mode of chlorination

  19. Nitric oxide treatment for the control of reverse osmosis membrane biofouling.

    Science.gov (United States)

    Barnes, Robert J; Low, Jiun Hui; Bandi, Ratnaharika R; Tay, Martin; Chua, Felicia; Aung, Theingi; Fane, Anthony G; Kjelleberg, Staffan; Rice, Scott A

    2015-04-01

    Biofouling remains a key challenge for membrane-based water treatment systems. This study investigated the dispersal potential of the nitric oxide (NO) donor compound, PROLI NONOate, on single- and mixed-species biofilms formed by bacteria isolated from industrial membrane bioreactor and reverse osmosis (RO) membranes. The potential of PROLI NONOate to control RO membrane biofouling was also examined. Confocal microscopy revealed that PROLI NONOate exposure induced biofilm dispersal in all but two of the bacteria tested and successfully dispersed mixed-species biofilms. The addition of 40 μM PROLI NONOate at 24-h intervals to a laboratory-scale RO system led to a 92% reduction in the rate of biofouling (pressure rise over a given period) by a bacterial community cultured from an industrial RO membrane. Confocal microscopy and extracellular polymeric substances (EPS) extraction revealed that PROLI NONOate treatment led to a 48% reduction in polysaccharides, a 66% reduction in proteins, and a 29% reduction in microbial cells compared to the untreated control. A reduction in biofilm surface coverage (59% compared to 98%, treated compared to control) and average thickness (20 μm compared to 26 μm, treated compared to control) was also observed. The addition of PROLI NONOate led to a 22% increase in the time required for the RO module to reach its maximum transmembrane pressure (TMP), further indicating that NO treatment delayed fouling. Pyrosequencing analysis revealed that the NO treatment did not significantly alter the microbial community composition of the membrane biofilm. These results present strong evidence for the application of PROLI NONOate for prevention of RO biofouling. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Nitric Oxide Treatment for the Control of Reverse Osmosis Membrane Biofouling

    Science.gov (United States)

    Barnes, Robert J.; Low, Jiun Hui; Bandi, Ratnaharika R.; Tay, Martin; Chua, Felicia; Aung, Theingi; Fane, Anthony G.; Kjelleberg, Staffan

    2015-01-01

    Biofouling remains a key challenge for membrane-based water treatment systems. This study investigated the dispersal potential of the nitric oxide (NO) donor compound, PROLI NONOate, on single- and mixed-species biofilms formed by bacteria isolated from industrial membrane bioreactor and reverse osmosis (RO) membranes. The potential of PROLI NONOate to control RO membrane biofouling was also examined. Confocal microscopy revealed that PROLI NONOate exposure induced biofilm dispersal in all but two of the bacteria tested and successfully dispersed mixed-species biofilms. The addition of 40 μM PROLI NONOate at 24-h intervals to a laboratory-scale RO system led to a 92% reduction in the rate of biofouling (pressure rise over a given period) by a bacterial community cultured from an industrial RO membrane. Confocal microscopy and extracellular polymeric substances (EPS) extraction revealed that PROLI NONOate treatment led to a 48% reduction in polysaccharides, a 66% reduction in proteins, and a 29% reduction in microbial cells compared to the untreated control. A reduction in biofilm surface coverage (59% compared to 98%, treated compared to control) and average thickness (20 μm compared to 26 μm, treated compared to control) was also observed. The addition of PROLI NONOate led to a 22% increase in the time required for the RO module to reach its maximum transmembrane pressure (TMP), further indicating that NO treatment delayed fouling. Pyrosequencing analysis revealed that the NO treatment did not significantly alter the microbial community composition of the membrane biofilm. These results present strong evidence for the application of PROLI NONOate for prevention of RO biofouling. PMID:25636842

  1. Integrating forward osmosis into microbial fuel cells for wastewater treatment, water extraction and bioelectricity generation.

    Science.gov (United States)

    Zhang, Fei; Brastad, Kristen S; He, Zhen

    2011-08-01

    A novel osmotic microbial fuel cell (OsMFC) was developed by using a forward osmosis (FO) membrane as a separator. The performance of the OsMFC was examined with either NaCl solution or artificial seawater as a catholyte (draw solution). A conventional MFC with a cation exchange membrane was also operated in parallel for comparison. It was found that the OsMFC produced more electricity than the MFC in both batch operation (NaCl solution) and continuous operation (seawater), likely due to better proton transport with water flux through the FO membrane. Water flux from the anode into the cathode was clearly observed with the OsMFC but not in the MFC. The solute concentration of the catholyte affected both electricity generation and water flux. These results provide a proof of concept that an OsMFC can simultaneously accomplish wastewater treatment, water extraction (from the wastewater), and electricity generation. The potential applications of the OsMFC are proposed for either water reuse (linking to reverse osmosis for reconcentration of draw solution) or seawater desalination (connecting with microbial desalination cells for further wastewater treatment and desalination).

  2. Feasibility of the inverse osmosis; La viabilidad de la osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Farinas Iglesias, M.

    1999-11-01

    Within the different alternatives to the treatment of the water, the inverse osmosis is presented like the most interesting system, avant-garde and economical susceptible of investigation. Manuel Farinas exposes in the REVERSE OSMOSIS, the costs of the cubic meter of hasty water, as well as of other products gotten with this technic. (Author)

  3. Conceptual design and cost study for a dual-purpose nuclear-electric reverse osmosis seawater conversion plant

    Energy Technology Data Exchange (ETDEWEB)

    1979-04-01

    The objective of this study was to develop a conceptual design and cost estimate for a 25 million gallon per day seawater reverse osmosis desalting plant operating at both Caribbean and Persian Gulf sites. The plant would operate in conjunction with a 1000 MW(e) nuclear power plant. Four seawater membrane manufacturers were supplied with feedwater analysis and a simplified cost estimating procedure in order to recommend membrane systems which would be applicable. For both sites a two-stage system was selected for development of a conceptual cost estimate. The product water cost was found to be (based upon 1978 United States construction costs) $3.17/1000 gallons for the Caribbean site and $3.75/1000 gallons for the Persian Gulf site.

  4. Effectiveness of seawater reverse osmosis (SWRO) pretreatment systems in removing transparent exopolymer particles (TEP) substances

    KAUST Repository

    Lee, Shang-Tse

    2015-05-01

    Transparent exopolymer particles (TEP) have been reported as one of the main factors of membrane fouling in seawater reverse osmosis (SWRO) process. Research has been focused on algal TEP so far, overlooking bacterial TEP. This thesis investigated the effects of coagulation on removal of bacterial TEP/TEP precursors in seawater and subsequent reduction on TEP fouling in ultrafiltration (UF), as a pretreatment of SWRO. Furthermore, the performance of pretreatment (coagulation + UF) has been investigated on a bench-scale SWRO system. TEP/TEP precursors were harvested from a strain of marine bacteria, Pseudoalteromonas atlantica, isolated from the Red Sea. Isolated bacterial organic matter (BOM), containing 1.5 mg xanthan gum eq./L TEP/TEP precursors, were dosed in Red Sea water to mimic a high TEP concentration event. Bacterial TEP/TEP precursors added to seawater were coagulated with ferric chloride and aluminum sulfate at different dosages and pH. Results showed that ferric chloride had a better removal efficiency on TEP/TEP precursors. Afterwards, the non-coagulated/coagulated seawater were tested on a UF system at a constant flux of 130 L/m2h, using two types of commercially available membranes, with pore sizes of 50 kDa and 100 kDa, respectively. The fouling potential of coagulated water was determined by the Modified Fouling Index (MFI-UF). Transmembrane pressure (TMP) was also continuously monitored to investigate the fouling development on UF membranes. TEP concentrations in samples were determined by the alcian blue staining assay. Liquid chromatography-organic carbon detection (LC-OCD) was used to determine the removal of TEP precursors with particular emphasis on biopolymers. Finally, SWRO tests showed that TEP/TEP precursors had a high fouling potential as indicated by MFI-UF, corresponding to the TMP measurements. Coagulation could substantially reduce TEP/TEP precursors fouling in UF when its dosage was equal or higher than 0.2 mg Fe/L. The flux decline

  5. Predicting and measurement of pH of seawater reverse osmosis concentrates

    KAUST Repository

    Waly, Tarek

    2011-10-01

    The pH of seawater reverse osmosis plants (SWRO) is the most influential parameter in determining the degree of supersaturation of CaCO3 in the concentrate stream. For this, the results of pH measurements of the concentrate of a seawater reverse osmosis pilot plant were compared with pH calculations based on the CO2-HCO3 --CO3 2- system equilibrium equations. Results were compared with two commercial software programs from membrane suppliers and also the software package Phreeqc. Results suggest that the real concentrate pH is lower than that of the feed and that none of the used programs was able to predict correctly real pH values. In addition, the effect of incorporating the acidity constant calculated for NaCl medium or seawater medium showed a great influence on the concentrate pH determination. The HCO3 - and CO3 2- equilibrium equation using acidity constants developed for seawater medium was the only method able to predict correctly the concentrate pH. The outcome of this study indicated that the saturation level of the concentrate was lower than previously anticipated. This was confirmed by shutting down the acid and the antiscalants dosing without any signs of scaling over a period of 12 months. © 2011 Elsevier B.V.

  6. Biochar-based constructed wetlands to treat reverse osmosis rejected concentrates in chronic kidney disease endemic areas in Sri Lanka.

    Science.gov (United States)

    Athapattu, B C L; Thalgaspitiya, T W L R; Yasaratne, U L S; Vithanage, Meththika

    2017-12-01

    The objectives were to investigate the potential remedial measures for reverse osmosis (RO) rejected water through constructed wetlands (CWs) with low-cost materials in the media established in chronic kidney disease of unknown etiology (CKDu) prevalent area in Sri Lanka. A pilot-scale surface and subsurface water CWs were established at the Medawachchiya community-based RO water supply unit. Locally available soil, calicut tile and biochar were used in proportions of 81, 16.5 and 2.5% (w/w), respectively, as filter materials in the subsurface. Vetiver grass and Scirpus grossus were selected for subsurface wetland while water lettuce and water hyacinth were chosen for free water surface CWs. Results showed that the CKDu sensitive parameters; total dissolved solids, hardness, total alkalinity and fluoride were reduced considerably (20-85%) and most met desirable levels of stipulated ambient standards. Biochar seemed to play a major role in removing fluoride from the system which may be due to the existing and adsorbed K + , Ca +2 , Mg +2 , etc. on the biochar surface via chemisorption. The least reduction was observed for alkalinity. This study indicated potential purification of aforesaid ions in water which are considerably present in RO rejection. Therefore, the invented bio-geo constructed wetland can be considered as a sustainable, economical and effective option for reducing high concentrations of CKDu sensitive parameters in RO rejected water before discharging into the inland waters.

  7. Biofouling potential reductions using a membrane hybrid system as a pre-treatment to seawater reverse osmosis.

    Science.gov (United States)

    Jeong, Sanghyun; Kim, Lan Hee; Kim, Sung-Jo; Nguyen, Tien Vinh; Vigneswaran, Saravanamuthu; Kim, In S

    2012-07-01

    Biofouling on reverse osmosis (RO) membranes is the most serious problem which affects desalination process efficiency and increases operation cost. The biofouling cannot be effectively removed by the conventional pre-treatment traditionally used in desalination plants. Hybrid membrane systems coupling the adsorption and/or coagulation with low-pressure membranes can be a sustainable pre-treatment in reducing membrane fouling and at the same time improving the feed water quality to the seawater reverse osmosis. The addition of powder activated carbon (PAC) of 1.5 g/L into submerged membrane system could help to remove significant amount of both hydrophobic compounds (81.4%) and hydrophilic compounds (73.3%). When this submerged membrane adsorption hybrid system (SMAHS) was combined with FeCl(3) coagulation of 0.5 mg of Fe(3+)/L, dissolved organic carbon removal efficiency was excellent even with lower dose of PAC (0.5 g/L). Detailed microbial studies conducted with the SMAHS and the submerged membrane coagulation-adsorption hybrid system (SMCAHS) showed that these hybrid systems can significantly remove the total bacteria which contain also live cells. As a result, microbial adenosine triphosphate (ATP) as well as total ATP concentrations in treated seawater and foulants was considerably decreased. The bacteria number in feed water prior to RO reduced from 5.10E(+06) cells/mL to 3.10E(+03) cells/mL and 9.30E(+03) cells/mL after SMAHS and SMCAHS were applied as pre-treatment, respectively. These led to a significant reduction of assimilable organic carbon (AOC) by 10.1 μg/L acetate-C when SMCAHS was used as a pre-treatment after 45-h RO operation. In this study, AOC method was modified to measure the growth of bacteria in seawater by using the Pseudomonas P.60 strain.

  8. Removal of toxic ions (chromate, arsenate, and perchlorate) using reverse osmosis, nanofiltration, and ultrafiltration membranes

    KAUST Repository

    Yoon, Jaekyung

    2009-09-01

    Rejection characteristics of chromate, arsenate, and perchlorate were examined for one reverse osmosis (RO, LFC-1), two nanofiltration (NF, ESNA, and MX07), and one ultrafiltration (UF and GM) membranes that are commercially available. A bench-scale cross-flow flat-sheet filtration system was employed to determine the toxic ion rejection and the membrane flux. Both model and natural waters were used to prepare chromate, arsenate, and perchlorate solutions (approximately 100 μg L-1 for each anion) in mixtures in the presence of other salts (KCl, K2SO4, and CaCl2); and at varying pH conditions (4, 6, 8, and 10) and solution conductivities (30, 60, and 115 mS m-1). The rejection of target ions by the membranes increases with increasing solution pH due to the increasingly negative membrane charge with synthetic model waters. Cr(VI), As(V), and ClO4 - rejection follows the order LFC-1 (>90%) > MX07 (25-95%) ≅ ESNA (30-90%) > GM (3-47%) at all pH conditions. In contrast, the rejection of target ions by the membranes decreases with increasing solution conductivity due to the decreasingly negative membrane charge. Cr(VI), As(V), and ClO4 - rejection follows the order CaCl2 < KCl ≅ K2SO4 at constant pH and conductivity conditions for the NF and UF membranes tested. For natural waters the LFC-1 RO membrane with a small pore size (0.34 nm) had a significantly greater rejection for those target anions (>90%) excluding NO3 - (71-74%) than the ESNA NF membrane (11-56%) with a relatively large pore size (0.44 nm), indicating that size exclusion is at least partially responsible for the rejection. The ratio of solute radius (ri,s) to effective membrane pore radius (rp) was employed to compare ion rejection. For all of the ions, the rejection is higher than 70% when the ri,s/rp ratio is greater than 0.4 for the LFC-1 membrane, while for di-valent ions (CrO4 2 -, SO4 2 -, and HAsSO4 2 -) the rejection (38-56%) is fairly proportional to the ri,s/rp ratio (0.32-0.62) for the ESNA

  9. Comparison of Energy Efficiency and Power Density in Pressure Retarded Osmosis and Reverse Electrodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Yip, NY; Elimelech, M

    2014-09-16

    Pressure retarded osmosis (PRO) and reverse electrodialysis (RED) are emerging membrane-based technologies that can convert chemical energy in salinity gradients to useful work. The two processes have intrinsically different working principles: controlled mixing in PRO is achieved by water permeation across salt-rejecting membranes, whereas RED is driven by ion flux across charged membranes. This study compares the energy efficiency and power density performance of PRO and RED with simulated technologically available membranes for natural, anthropogenic, and engineered salinity gradients (seawater-river water, desalination brine-wastewater, and synthetic hypersaline solutions, respectively). The analysis shows that PRO can achieve both greater efficiencies (54-56%) and higher power densities (2.4-38 W/m(2)) than RED (18-38% and 0.77-1.2 W/m(2)). The superior efficiency is attributed to the ability of PRO membranes to more effectively utilize the salinity difference to drive water permeation and better suppress the detrimental leakage of salts. On the other hand, the low conductivity of currently available ion exchange membranes impedes RED ion flux and, thus, constrains the power density. Both technologies exhibit a trade-off between efficiency and power density: employing more permeable but less selective membranes can enhance the power density, but undesired entropy production due to uncontrolled mixing increases and some efficiency is sacrificed. When the concentration difference is increased (i.e., natural -> anthropogenic -> engineered salinity gradients), PRO osmotic pressure difference rises proportionally but not so for RED Nernst potential, which has logarithmic dependence on the solution concentration. Because of this inherently different characteristic, RED is unable to take advantage of larger salinity gradients, whereas PRO power density is considerably enhanced. Additionally, high solution concentrations suppress the Donnan exclusion effect of the

  10. Feasibility Analysis of a Seabed Filtration Intake System for the Shoaiba III Expansion Reverse Osmosis Plant

    KAUST Repository

    Rodríguez, Luis Raúl

    2012-06-01

    The ability to economically desalinate seawater in arid regions of the world has become a vital advancement to overcome the problem on freshwater availability, quality, and reliability. In contrast with the major capital and operational costs for desalination plants represented by conventional open ocean intakes, subsurface intakes allow the extraction of high quality feed water at minimum costs and reduced environmental impact. A seabed filter is a subsurface intake that consists of a submerged slow sand filter, with benefits of organic matter removal and pathogens, and low operational cost. A site investigation was carried out through the southern coast of the Red Sea in Saudi Arabia, from King Abdullah University of Science and Technology down to 370 kilometers south of Jeddah. A site adjacent to the Shoaiba desalination plant was selected to assess the viability of constructing a seabed filter. Grain sieve size analysis, porosity and hydraulic conductivity permeameter measurements were performed on the collected sediment samples. Based on these results, it was concluded that the characteristics at the Shoaiba site allow for the construction of a seabed filtration system. A seabed filter design is proposed for the 150,000 m3/d Shoaiba III expansion project, a large-scale Reverse Osmosis desalination plant. A filter design with a filtration rate of 7 m/d through an area of 6,000 m2 is proposed to meet the demand of one of the ten desalination trains operating at the plant. The filter would be located 90 meters offshore where hydraulic conductivity of the sediment is high, and mud percentage is minimal. The thin native marine sediment layer is insufficient to provide enough water filtration, and consequently the proposed solution involves excavating the limestone rock and filling it with different layers of non-native sand and gravel of increasing grain size. An initial assessment of the area around Shoaiba showed similar sedimentological conditions that could

  11. Preventing colloidal fouling in reverse osmosis and nano filtration system. Application of electron beam surface analysis; Prevencion del ensuciamiento coloidal en sistemas de osmosis inversa y nanofiltracion. Aplicacion del analisis de superficies con haces de electrones.

    Energy Technology Data Exchange (ETDEWEB)

    Sanz Ataz, J.; Guerrero Gallego, L.; Taberna Camprubi, E.; Pena Garcia, N.M; Carulla Contreras, C.; Blavia Bergos, J.

    2003-07-01

    Particulate matter in natural waters and wastewaters can cause fouling in reverse osmosis and nano filtration membranes. Common foulants includes organic and inorganic colloids; hydrous aluminum and iron silicates, silt, iron and manganese oxides, calcium carbonate, microorganisms, polysaccharides, lipoproteins, biological debris, etc. Predicting fouling of dispersed materials on membrane surface and brine flow channels uses the silt density index (SDI) and modified fouling index (MFI). Scanning electron microscopy (SEM) coupled with energy X-ray microanalysis (EDX) of SDI filters contributes to obtain information about shape, size and chemical composition of foulants and cake layer. (Author) 6 refs.

  12. Characterization and effect of biofouling on polyamide reverse osmosis and nanofiltration membrane surfaces.

    Science.gov (United States)

    Khan, Mohiuddin Md Taimur; Stewart, Philip S; Moll, David J; Mickols, William E; Nelson, Sara E; Camper, Anne K

    2011-02-01

    Biofouling is a major reason for flux decline in the performance of membrane-based water and wastewater treatment plants. Initial biochemical characterization of biofilm formation potential and biofouling on two commercially available membrane surfaces from FilmTec Corporation were investigated without filtration in laboratory rotating disc reactor systems. These surfaces were polyamide aromatic thin-film reverse osmosis (RO) (BW30) and semi-aromatic nanofiltration (NF270) membranes. Membrane swatches were fixed on removable coupons and exposed to water with indigenous microorganisms supplemented with 1.5 mg l(-1) organic carbon under continuous flow. After biofilms formed, the membrane swatches were removed for analyses. Staining and epifluorescence microscopy revealed more cells on the RO than on the NF surface. Based on image analyses of 5-μm thick cryo-sections, the accumulation of hydrated biofoulants on the RO and NF surfaces exceeded 0.74 and 0.64 μm day(-1), respectively. As determined by contact angle the biofoulants increased the hydrophobicity up to 30° for RO and 4° for NF surfaces. The initial difference between virgin RO and NO hydrophobicities was ∼5°, which increased up to 25° after biofoulant formation. The initial roughness of RO and NF virgin surfaces (75.3 nm and 8.2 nm, respectively) increased to 48 nm and 39 nm after fouling. A wide range of changes of the chemical element mass percentages on membrane surfaces was observed with X-ray photoelectron spectroscopy. The initial chemical signature on the NF surface was better restored after cleaning than the RO membrane. All the data suggest that the semi-aromatic NF surface was more biofilm resistant than the aromatic RO surface. The morphology of the biofilm and the location of active and dead cell zones could be related to the membrane surface properties and general biofouling accumulation was associated with changes in the surface chemistry of the membranes, suggesting the validity of

  13. INFLUENCE AT DIFFERENT OPERATION CONDITIONS ON THE ACEROLA JUICE CONCENTRATION BY REVERSE OSMOSIS, USING SPIRAL MEMBRANE OF COMPOSITE FILM

    Directory of Open Access Journals (Sweden)

    E. R.S. GOMES

    2009-03-01

    Full Text Available

    The concentration of acerola juice, involves removal of water with the objective of reducing packing, storage and transport costs. The reverse osmosis (RO is a process of increasing interest in food industry and among the advantages they stand out: the low consumption of energy and the minimum thermal damages is caused to the products. The objective of this work was to evaluate the influence of different operation conditions in relation to the permeate flux, in the concentration process of the acerola juice by RO. All the RO experiments were carried out with retentate recycling. The concentration by RO, were carried on the transmembrane pressures of 20, 30 and 40 bar and at 23ºC and 40ºC, being used a membrane of composite film in spiral module (99% NaCl rejection. The acerola pulp was defrosted and treated with Citrozym Ultra L enzyme (100 ppm, 45ºC ,1 hour, then it was ultrafiltrated at 3 bar at the same temperature, in 0.1 µm ceramic membrane, and so it was concentrated by RO. It was verified that the pressure and the temperature influenced the concentration and the permeate flux obtained in the RO process. The flux decreased along the processing, once the feeding becomes more concentrate, increasing the viscosity, osmotic pressure and retained sugar. KEYWORDS: Acerola juice concentration; reverse osmosis; membrane of composite film.

  14. Efficient ozonation of reverse osmosis concentrates from petroleum refinery wastewater using composite metal oxide-loaded alumina

    National Research Council Canada - National Science Library

    Chen, Yu; Chen, Chun-Mao; Yoza, Brandon A; Li, Qing X; Guo, Shao-Hui; Wang, Ping; Dong, Shi-Jie; Wang, Qing-Hong

    2017-01-01

    Novel Mn–Fe–Mg- and Mn–Fe–Ce-loaded alumina (Mn–Fe–Mg/Al2O3 and Mn–Fe–Ce/Al2O3) were developed to catalytically ozonate reverse osmosis concentrates generated from petroleum refinery wastewaters (PRW-ROC...

  15. Ozone and biofiltration as an alternative to reverse osmosis for removing PPCPs and micropollutants from treated wastewater

    DEFF Research Database (Denmark)

    Lee, Carson; Howe, Kerry J.; Thomson, Bruce M.

    2012-01-01

    This pilot-scale research project investigated and compared the removal of pharmaceuticals and personal care products (PPCPs) and other micropollutants from treated wastewater by ozone/biofiltration and reverse osmosis (RO). The reduction in UV254 absorbance as a function of ozone dose correlated...

  16. Biofouling of reverse-osmosis membranes during tertiary wastewater desalination: microbial community composition.

    Science.gov (United States)

    Al Ashhab, Ashraf; Herzberg, Moshe; Gillor, Osnat

    2014-03-01

    Reverse-osmosis (RO) desalination is frequently used for the production of high-quality water from tertiary treated wastewater (TTWW). However, the RO desalination process is often hampered by biofouling, including membrane conditioning, microbial adhesion, and biofilm growth. The vast majority of biofilm exploration concentrated on the role of bacteria in biofouling neglecting additional microbial contributors, i.e., fungi and archaea. To better understand the RO biofouling process, bacterial, archaeal and fungal diversity was characterized in a laboratory-scale RO desalination plant exploring the TTWW (RO feed), the RO membrane and the RO feed tube biofilms. We sequenced 77,400 fragments of the ribosome small subunit-encoding gene (16S and 18S rRNA) to identify the microbial community members in these matrices. Our results suggest that the bacterial, archaeal but not fungal community significantly differ from the RO membrane biofouling layer to the feedwater and tube biofilm (P < 0.01). Moreover, the RO membrane supported a more diverse community compared to the communities monitored in the feedwater and the biofilm attached to the RO feedwater tube. The tube biofilm was dominated by Actinobacteria (91.2 ± 4.6%), while the Proteobacteria phylum dominated the feedwater and RO membrane (at relative abundance of 92.3 ± 4.4% and 71.5 ± 8.3%, respectively), albeit comprising different members. The archaea communities were dominated by Crenarchaeota (53.0 ± 6.9%, 32.5 ± 7.2% and 69%, respectively) and Euryarchaeota (43.3 ± 6.3%, 23.2 ± 4.8% and 24%, respectively) in all three matrices, though the communities' composition differed. But the fungal communities composition was similar in all matrices, dominated by Ascomycota (97.6 ± 2.7%). Our results suggest that the RO membrane is a selective surface, supporting unique bacterial, and to a lesser extent archaeal communities, yet it does not select for a fungal community. Copyright © 2013

  17. Optimization of the Sequence of Washing Reverse Osmosis Membranes Used for Seawater Desalination

    Directory of Open Access Journals (Sweden)

    S. Gutierrez-Ruiz

    2017-04-01

    Full Text Available Seawater contains a number of organic and inorganic components that cause fouling of membranes when subjected to a process of reverse osmosis desalination. This fouling is one of the most important problems in the management of desalination plants, as it entails a significant loss in system performance. For membranes to be able to continue operating under appropriate conditions, they must undergo periodic cleaning protocols. This paper presents the results obtained when, subjecting a previously fouled aromatic polyamide membrane to different washing agents and using different concentrations of the same. Optimal concentrations of cleaning reagents were established. The results indicate that the performance of cleaning using a mixture of reagents, and alternating alkaline and acidic media, enabled maximum recovery of the membrane permeate flux (94.2 % and a significant reduction in the consumption of cleaning reagents.

  18. Low-temperature distillation plants: a comparison with seawater reverse osmosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D.

    1981-07-01

    Low-temperature distillation plants using large aluminum-alloy heat-transfer surfaces have reduced energy requirements to levels projected today for second-generation seawater reverse-osmosis (SWRO) plants. Less sensitive to feed contamination, and totally free from maintenance associated with a complex and critical feed-pretreatment system and periodic membrane replacements, the low-temperature distillation plants out-perform SWRO plants also by their higher-quality product, 2-10 ppM TDS versus 300 to 1000 ppM TDS. Energy requirements and operating costs for Low Temperature Vapor Compression (LT-VC) and Multi-Effect-Distillation (LT-MED) plants, in dual-purpose and various waste-heat-utilization schemes, are compared with those of SWRO plants. 10 references, 14 figures, 8 tables.

  19. Use of reverse osmosis membranes for the separation of lemongrass essential oil and supercritical CO2

    Directory of Open Access Journals (Sweden)

    L.A.V. Sarmento

    2004-06-01

    Full Text Available Although it is still used very little by industry, the process of essential oil extraction from vegetable matrices with supercritical CO2 is regarded as a potentially viable technique. The operation of separating the extract from the solvent is carried out by reducing the pressure in the system. Separation by membranes is an alternative that offers lower energy consumption and easier operation than traditional methods of separation. Combining the processes essential oil extraction with supercritical CO2 and separation by membranes permits the separation of solvent and oil without the need for large variations in extraction conditions. This results in a large energy savings in the case of solvent repressurisation and reuse. In this study, the effectiveness of reverse osmosis membranes in separating lemongrass essential oil from mixtures with supercritical CO2 was tested. The effects of feed oil concentration and transmembrane pressure on CO2 permeate flux and oil retention were studied for three membrane models.

  20. Cleaning efficacy of hydroxypropyl-beta-cyclodextrin for biofouling reduction on reverse osmosis membranes.

    Science.gov (United States)

    Alayande, Abayomi Babatunde; Kim, Lan Hee; Kim, In S

    2016-01-01

    In this study, an environmentally friendly compound, hydroxypropyl-beta-cyclodextrin (HP-β-CD) was applied to clean reverse osmosis (RO) membranes fouled by microorganisms. The cleaning with HP-β-CD removed the biofilm and resulted in a flux recovery ratio (FRR) of 102%. As cleaning efficiency is sometimes difficult to determine using flux recovery data alone, attached bacterial cells and extracellular polymeric substances (EPS) were quantified after cleaning the biofouled membrane with HP-β-CD. Membrane surface characterization using scanning electron microscopy (SEM), attenuated total reflectance Fourier transform infrared (ATR-FTIR) and atomic force microscopy (AFM) confirmed the effectiveness of HP-β-CD in removal of biofilm from the RO membrane surface. Finally, a comparative study was performed to investigate the competitiveness of HP-β-CD with other known cleaning agents such as sodium dodecyl sulfate (SDS), ethylenediaminetetraacetic acid (EDTA), Tween 20, rhamnolipid, nisin, and surfactin. In all cases, HP-β-CD was superior.

  1. Bacterial bioluminescence response to long-term exposure to reverse osmosis treated effluents from dye industries.

    Science.gov (United States)

    Ravindran, J; Manikandan, B; Shirodkar, P V; Francis, K X; Mani Murali, R; Vethamony, P

    2014-10-01

    The bacterial bioluminescence assay is one of the novel means for toxicity detection. The bioluminescence response of 2 marine bioluminescent bacteria was tested upon their long-term exposure to 9 different reverse osmosis (RO) rejects with varying chemical composition sampled from various dye industries. Bioluminescent bacteria were cultured in the RO reject samples, at different concentrations, and their growth rate and luminescence was measured for 24 h. The RO reject samples caused sublethal effects upon exposure and retarded the growth of bacteria, confirming their toxic nature. Further, continuation of the exposure showed that the initial luminescence, though reduced, recovered and increased beyond the control cultures irrespective of cell density, and finally decreased once again. The present study emphasizes the need of evolving a long-term exposure assay and shows that the method followed in this study is suitable to evaluate the toxicants that exert delayed toxicity, using lower concentrations of toxicants as well as coloured samples.

  2. Co-generation project for the Combined Cycle Power Plant President Juarez Rosarito and a reverse osmosis desalting plant; Proyecto de cogeneracion para la planta de ciclo combinado Presidente Juarez Rosarito y una planta desaladora de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Beltran Mora, Hector; Espindola Hernandez, Salvador [Universidad NAcional Autonoma de Mexico (UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    In this work a technical and economical analysis of the installation of a reverse osmosis desalting plant connected to a power station that uses the combined cycle technology under a co-generation scheme is presented: production of electricity and water. The operation program of the desalting power station will be determined by the demand of energy of the combined cycle power station; the proposal is that the desalting plant operates in the hours of low load of the power station and shuts down at the peak hours of electrical energy demand. So that this study is representative, the demand curves of electric energy of the units of combined cycle of Central President Juarez Rosarito of the Comision Federal de Electricidad (CFE) have been taken and updated the data of the reverse osmosis desalting plants that are available at the moment in the market. As basis of the study the level costs will be determined so much as the electrical energy generated by the power station of combined cycle, operating inside and outside of a co-generation scheme and the costs made level for the water produced by the reverse osmosis plant under two assumptions: the first one is buying the electrical energy from CFE and the second one considering that the CFE is the owner of the desalting plant and therefore the cost of electrical energy to desalting the plant is zero. This work shows the economic impacts on the costs of the generation of electrical energy and on those of the desalted water in a co-generation scheme. The results shown in this study can be considered for the future planning in the construction of desalting plants to supply of water in the Northwestern zones of the country where serious problems of water shortage exist. [Spanish] En este trabajo se presenta un analisis tecnico y economico de la instalacion de una planta desaladora de osmosis inversa acoplada a una central de generacion de energia electrica que utiliza la tecnologia de ciclo combinado bajo un esquema de

  3. Purifying fluoride-contaminated water by a novel forward osmosis design with enhanced flux under reduced concentration polarization.

    Science.gov (United States)

    Pal, Madhubonti; Chakrabortty, Sankha; Pal, Parimal; Linnanen, Lassi

    2015-08-01

    For purifying fluoride-contaminated water, a new forward osmosis scheme in horizontal flat-sheet cross flow module was designed and investigated. Effects of pressure, cross flow rate, draw solution and alignment of membrane module on separation and flux were studied. Concentration polarization and reverse salt diffusion got significantly reduced in the new hydrodynamic regime. This resulted in less membrane fouling, better solute separation and higher pure water flux than in a conventional module. The entire scheme was completed in two stages-an upstream forward osmosis for separating pure water from contaminated water and a downstream nanofiltration operation for continuous recovery and recycle of draw solute. Synchronization of these two stages of operation resulted in a continuous, steady-state process. From a set of commercial membranes, two polyamide composite membranes were screened out for the upstream and downstream filtrations. A 0.3-M NaCl solution was found to be the best one for forward osmosis draw solution. Potable water with less than 1% residual fluoride could be produced at a high flux of 60-62 L m(-2) h(-1) whereas more than 99% draw solute could be recovered and recycled in the downstream nanofiltration stage from where flux was 62-65 L m(-2) h(-1).

  4. Advantages of the appropriate selection of reverse osmosis membranes in desalination plants with open intake; Ventajs de una adecuada seleccion de membranas de osmosis inversa en plants desaladoras con captacion superficial abierta

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Elguera, A.; Nishida, M.

    2001-07-01

    It is hoped to make it sufficiently clear with this article that it is of fundamental importance that the reverse osmosis membranes and the conditions under which they will operate be appropriately selected. It is obvious that this choice must be made primarily in function of the quality of the water that will be processed in the water treatment plant ( for which reason it is of vital importance that a detailed study and careful characterisation of this water be carried out previously). This article report the highly encouraging results achieved with Cellulose Tri-acetate membranes in a singular Hollow fibre configuration, known commercially as Hollosep HM 10255FI (of Japanese manufacture), which were evaluated in parallel with LP3 potabilisation membranes that process sea water collected using an open intake system with high levels of microbiological pollution. (Author) 7 refs.

  5. Feasibility of municipal solid waste (MSW as energy sources for Saudi Arabia’s future Reverse osmosis (RO desalination plants

    Directory of Open Access Journals (Sweden)

    Agboola Phillips O.

    2016-12-01

    Full Text Available The Kingdom of Saudi Arabia (KSA generates between 1.4–1.75 kg/person/day of Municipal Solid Waste (MSW that accounts for over 16 million tons of MSW/year. The solid waste collected from different sources is dumped in landfills, thereby creating environmental concerns. In this paper, the potential of solid waste as an energy source (Waste to Energy (WTE for Reverse Osmosis (RO water purification was evaluated. The KSA is known for its acute fresh water shortages and uses desalination technology in meeting its daily water requirements; a process that is energy intensive. The evaluation of the energy content of MSW shows a potential to produce about 927 MW in 2015, based on a total mass burn, and about 1,692 MW in 2032. The MSW-WTE plants can produce about 1.5% of the targeted 120 GW of energy for 2032. For the R.O system, it will give approximately 16.8% of the daily fresh water needed for total mass burn and 2.4% with the recycling option.

  6. Reverse osmosis followed by activated carbon filtration for efficient removal of organic micropollutants from river bank filtrate.

    Science.gov (United States)

    Kegel, F Schoonenberg; Rietman, B M; Verliefde, A R D

    2010-01-01

    Drinking water utilities in Europe are faced with a growing presence of organic micropollutants in their water sources. The aim of this research was to assess the robustness of a drinking water treatment plant equipped with reverse osmosis and subsequent activated carbon filtration for the removal of these pollutants. The total removal efficiency of 47 organic micropollutants was investigated. Results indicated that removal of most organic micropollutants was high for all membranes tested. Some selected micropollutants were less efficiently removed (e.g. the small and polar NDMA and glyphosate, and the more hydrophobic ethylbenzene and napthalene). Very high removal efficiencies for almost all organic micropollutants by the subsequent activated carbon, fed with the permeate stream of the RO element were observed except for the very small and polar NDMA and 1,4-dioxane. RO and subsequent activated carbon filtration are complementary and their combined application results in the removal of a large part of these emerging organic micropollutants. Based on these experiments it can be concluded that the robustness of a proposed treatment scheme for the drinking water treatment plant Engelse Werk is sufficiently guaranteed.

  7. High-performance polyamide thin-film-nanocomposite reverse osmosis membranes containing hydrophobic zeolitic imidazolate framework-8

    KAUST Repository

    Duan, Jintang

    2015-02-01

    A hydrophobic, hydrothermally stable metal-organic framework (MOF) - zeolitic imidazolate framework-8 (ZIF-8) was successfully incorporated into the selective polyamide (PA) layer of thin-film nanocomposite (TFN) membranes for water desalination. The potential advantages of ZIF-8 over classic hydrophilic zeolite used in TFNs include: i) theoretically faster water transport within the framework and ii) better compatibility with the PA matrix. The TFN membranes were characterized with SEM, TEM, AFM, XPS, water contact angle measurements and reverse osmosis tests under 15.5bar hydraulic pressure with 2000ppm NaCl solution. Lab-made, nano-sized (~200nm) ZIF-8 increased water permeance to 3.35±0.08L/m2·h·bar at 0.4% (w/v) loading, 162% higher than the pristine PA membranes; meanwhile, high NaCl rejection was maintained. The TFN surface was less crosslinked and more hydrophilic than that of the pristine PA. A filler encapsulation mechanism was proposed for the effects of filler on TFN membrane surface morphology and properties. This study experimentally verified the potential use of ZIF-8 in advanced TFN RO membranes.

  8. Reverse osmosis pretreatment method for toxicity assessment of domestic wastewater using Vibrio qinghaiensis sp.-Q67.

    Science.gov (United States)

    Ma, Xiaoyan Y; Wang, Xiaochang C; Hao Ngo, Huu; Guo, Wenshan; Wu, Maoni N; Wang, Na

    2013-11-01

    Luminescent bacterial test is a fast and sensitive method for acute toxicity assessment of water and wastewater. In this study, an improved toxicity testing method was developed using the freshwater luminescent bacteria Vibrio qinghaiensis sp.-Q67 that involved pretreatment of water samples with reverse osmosis (RO) to eliminate the interferences caused by nutrients in concentrated samples and to improve the reliability and sensitivity of the analysis. Because water samples contain low concentrations of several target toxic substances, rapid acute toxicity testing method that is commonly employed does not achieve enough sensitivity. The proposed RO pretreatment could effectively enrich organic and inorganic substances in water samples to enable a more effective and sensitive toxicity evaluation. The kinetic characteristics of toxicity of raw sewage and secondary effluent were evaluated based on the relative luminescence unit (RLU) curves and time-concentration-effect surfaces. It was observed that when the exposure time was prolonged to 8-h or longer, the bacteria reached the logarithmic growth stage. Hence, the stimulating effects of the coexisting ions (such as Na(+), K(+), NO3(-)) in the concentrated samples could be well eliminated. A 10-h exposure time in proposed Q67 test was found to quantitatively evaluate the toxicity of the organic and inorganic pollutants in the RO-concentrated samples. © 2013 Elsevier Inc. All rights reserved.

  9. A Comprehensive Study on the Application of Reverse Osmosis (RO Technology for the Petroleum Industry Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Shahryar Jafarinejad

    2017-10-01

    Full Text Available Large quantities of oily wastewaters can be generated from the activities and processes in the petroleum industry which draining of these effluents not only pollutes the environment but also reduces the yield of oil and water. Therefore, development of treatment processes for petroleum industry wastewaters is vital in order to prevent serious environmental damage and provide a source of water for beneficial use. Reverse osmosis (RO can be the most common membrane process used for desalination from oily wastewater and can produce water suitable for reuse at the petroleum industry. In this study, the application of RO technology for the petroleum industry wastewater treatment in different laboratory, pilot, field, and industrial scales have been reviewed. In addition, membrane fouling control, performance efficiency, treatment system configurations, pretreatment methods, quality of treated water, and economic issues have been investigated. With mixtures as complex as petroleum industry wastewaters, membrane fouling becomes a significant hurdle to implement the RO-based purification system. Operating the system within the critical flux range or adding chemicals, and/or pretreatment can usually control membrane fouling. Salt rejection of RO membranes can be 99% or higher.

  10. Impact of Acid Cleaning on the Performance of PVDF UF Membranes in Seawater Reverse Osmosis Pretreatment

    KAUST Repository

    Alsogair, Safiya

    2016-05-05

    Low-pressure membrane systems such as Microfiltration (MF) and Ultrafiltration (UF) have been presented as viable option to pre-treatment systems in potable water applications. UF membranes are sporadically backwashed with ultra-filtered water to remove deposited matter from the membrane and restore it. Several factors that may cause permeability and selectivity decrease are involved and numerous procedures are applicable to achieve this objective. Membrane cleaning is the most important step required to maintain the characteristics of the membrane. This research was made with the purpose of investigating the effects of acid cleaning during chemically enhanced backwashing (CEB) on the performance of ultrafiltration (UF) membranes in seawater reverse osmosis (SWRO) pretreatment. To accomplish this, the questions made were: Does the acid addition (before or after the alkali CEB) influence the overall CEB cleaning effectiveness on Dow UF membrane? Does the CEB order of alkali (NaOCl) and acid (H2SO4) affect the overall CEB cleaning effectiveness? If yes, which order is better/worse? What is the optimal acid CEB frequency that will ensure the most reliable performance of the UF?. To answer this queries, a series of sequences were carried out with different types of chemical treatments: Only NaOCl, daily NaOCl plus weekly acid, daily NaOCl plus daily acid, and weekly acid plus daily NaOCl. To investigate the consequence of acid by studying the effect of operational data like the trans-pressure membrane, resistance or permeability and support that by the analytical experiments (organic, inorganic and microbial characterization). Microorganisms were removed almost completely at hydraulic cleaning and showed no difference with addition of acid. As a conclusion of the operational data the organic and inorganic chatacterization resulted in the elimination of the first sequence due to the acummulation of fouling over time, which produces that the cleaning increases downtime

  11. Effectiveness of household reverse-osmosis systems in a Western U.S. region with high arsenic in groundwater

    Science.gov (United States)

    Walker, M.; Seiler, R.L.; Meinert, M.

    2008-01-01

    It is well known to the public in Lahontan Valley in rural Nevada, USA, that local aquifers produce water with varied, but sometimes very high concentrations of arsenic (> 4??ppm). As a result, many residents of the area have installed household reverse-osmosis (RO) systems to produce drinking water. We examined performance of RO systems and factors associated with arsenic removal efficiency in 59 households in Lahontan Valley. The sampling results indicated that RO systems removed an average of 80.2% of arsenic from well water. In 18 of the 59 households, arsenic concentrations exceeded 10??ppb in treated water, with a maximum in treated water of 180??ppb. In 3 of the 59 households, RO treatment had little effect on specific conductance, indicating that the RO system was not working properly. Two main factors lead to arsenic levels in treated water exceeding drinking-water standards in the study area. First, arsenic concentrations were high enough in some Lahontan Valley wells that arsenic levels exceeded 10??ppb even though RO treatment removed more than 95% of the arsenic. Second, trivalent As+ 3 was the dominant arsenic species in approximately 15% of the wells, which significantly reduced treatment efficiency. Measurements of specific conductance indicated that efficiency in reducing arsenic levels did not always correlate with reductions in total dissolved solids. As a consequence, improvements in taste of the water or simple measurements of specific conductance made by technicians to test RO systems can mislead the public into assuming the water meets safety standards. Actual measurements of treated water are necessary to assure that household RO systems are reducing arsenic concentrations to safe levels, particularly in areas where groundwater has high arsenic concentrations or where As+ 3 is the dominant species. ?? 2007 Elsevier B.V. All rights reserved.

  12. Fertiliser drawn forward osmosis process: Pilot-scale desalination of mine impaired water for fertigation

    KAUST Repository

    Phuntsho, Sherub

    2016-02-20

    The pilot-scale fertiliser driven forward osmosis (FDFO) and nanofiltration (NF) system was operated in the field for about six months for the desalination of saline groundwater from the coal mining activities. Long-term operation of the FDFO-NF system indicates that simple hydraulic cleaning could effectively restore the water flux with minimal chemical cleaning frequency. No fouling/scaling issues were encountered with the NF post-treatment process. The study indicates that, FDFO-NF desalination system can produce water quality that meets fertigation standard. This study also however shows that, the diffusion of solutes (both feed and draw) through the cellulose triacetate (CTA) FO membrane could be one of the major issues. The FO feed brine failed to meet the effluent discharge standard for NH4+ and SO42+ (reverse diffusion) and their concentrations are expected to further increase at higher feed recovery rates. Low rejection of feed salts (Na+, Cl−) by FO membrane may result in their gradual build-up in the fertiliser draw solution (DS) in a closed FDFO-NF system eventually affecting the final water quality unless it is balanced by adequate bleeding from the system through NF and re-reverse diffusion towards the FO feed brine. Therefore, FO membrane with higher reverse flux selectivity than the CTA-FO membrane used in this study is necessary for the application of the FDFO desalination process.

  13. Study to determine the technical and economic feasibility of reclaiming chemicals used in micellar polymer and low tension surfactant flooding. Final report. [Ultrafiltration membranes and reverse osmosis membranes

    Energy Technology Data Exchange (ETDEWEB)

    Stephens, R.H.; Himmelblau, A.; Donnelly, R.G.

    1978-02-01

    Energy Resources Company has developed a technology for use with enhanced oil recovery to achieve emulsion breaking and surfactant recovery. By using ultrafiltration membranes, the Energy Resources Company process can dewater an oil-in-water type emulsion expected from enhanced oil recovery projects to the point where the emulsion can be inverted and treated using conventional emulsion-treating equipment. By using a tight ultrafiltration membrane or a reverse osmosis membrane, the Energy Resources Company process is capable of recovering chemicals such as surfactants used in micellar polymer flooding.

  14. Full-scale simulation of seawater reverse osmosis desalination processes for boron removal: Effect of membrane fouling.

    Science.gov (United States)

    Park, Pyung-Kyu; Lee, Sangho; Cho, Jae-Seok; Kim, Jae-Hong

    2012-08-01

    The objective of this study is to further develop previously reported mechanistic predictive model that simulates boron removal in full-scale seawater reverse osmosis (RO) desalination processes to take into account the effect of membrane fouling. Decrease of boron removal and reduction in water production rate by membrane fouling due to enhanced concentration polarization were simulated as a decrease in solute mass transfer coefficient in boundary layer on membrane surface. Various design and operating options under fouling condition were examined including single- versus double-pass configurations, different number of RO elements per vessel, use of RO membranes with enhanced boron rejection, and pH adjustment. These options were quantitatively compared by normalizing the performance of the system in terms of E(min), the minimum energy costs per product water. Simulation results suggested that most viable options to enhance boron rejection among those tested in this study include: i) minimizing fouling, ii) exchanging the existing SWRO elements to boron-specific ones, and iii) increasing pH in the second pass. The model developed in this study is expected to help design and optimization of the RO processes to achieve the target boron removal at target water recovery under realistic conditions where membrane fouling occurs during operation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Economic advantages to optimising chemical products in pre-treatment in reverse osmosis desalination plants; Ventajas economicas al optimizar los productos quimicos en el pretratamiento de plantas desaladoras por osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Elguera, A.; Alday Ansola, J.; Perez Baez, S. O.

    2001-07-01

    This article reports the results of a process of optimising the dosage of Sodium hypochlorite and Metabisulphite, performed on sea water in the pre-treatment division of the Las Palmas III reverse osmosis desalination plant, currently operated by Empresa Mixta de Aguas de las Palmas (EMALSA), responsible for providing drinking water to more than 400.000 people in the city of Las Palmas, capital of Grand Canary Island. The results of this optimisation process, contrary to the opinion of the operators of the plant, after reducing the amount of Metabisulphite normally used in the plant by 70%, and Sodium hypochlorite by 30%, there were no adverse effects on the microbiological quality of the sea water. Moreover, the performance of the membranes was improved (bad odors disappeared, along with organic material sediments, etc.). (Author) 9 refs.

  16. Relationship between performance deterioration of a polyamide reverse osmosis membrane used in a seawater desalination plant and changes in its physicochemical properties.

    Science.gov (United States)

    Suzuki, Tasuma; Tanaka, Ryohei; Tahara, Marina; Isamu, Yuya; Niinae, Masakazu; Lin, Lin; Wang, Jingbo; Luh, Jeanne; Coronell, Orlando

    2016-09-01

    While it is known that the performance of reverse osmosis membranes is dependent on their physicochemical properties, the existing literature studying membranes used in treatment facilities generally focuses on foulant layers or performance changes due to fouling, not on the performance and physicochemical changes that occur to the membranes themselves. In this study, the performance and physicochemical properties of a polyamide reverse osmosis membrane used for three years in a seawater desalination plant were compared to those of a corresponding unused membrane. The relationship between performance changes during long-term use and changes in physicochemical properties was evaluated. The results showed that membrane performance deterioration (i.e., reduced water flux, reduced contaminant rejection, and increased fouling propensity) occurred as a result of membrane use in the desalination facility, and that the main physicochemical changes responsible for performance deterioration were reduction in PVA coating coverage and bromine uptake by polyamide. The latter was likely promoted by oxidant residual in the membrane feed water. Our findings indicate that the optimization of membrane materials and processes towards maximizing the stability of the PVA coating and ensuring complete removal of oxidants in feed waters would minimize membrane performance deterioration in water purification facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. The fate of Transparent Exopolymer Particles (TEP) in integrated membrane systems: removal through pre-treatment processes and deposition on reverse osmosis membranes.

    Science.gov (United States)

    Villacorte, Loreen O; Kennedy, Maria D; Amy, Gary L; Schippers, Jan C

    2009-12-01

    The abundance of Transparent Exopolymer Particles (TEP) in surface waters has been unnoticed for many years until recently as a potential foulant in reverse osmosis systems. Recent studies indicate that TEP may cause organic and biological fouling and may enhance particulate/colloidal fouling in reverse osmosis membranes. The presence of TEP was measured in the raw water, the pre-treatment processes and reverse osmosis (RO) systems of 6 integrated membrane installations. A spectrophotometric method was used to measure TEP in the particulate size range (>0.40microm) and was extended to measure TEP in the colloidal size range (0.05-0.40microm). Ultrafiltration pre-treatment applied in 4 plants, totally removed particulate TEP while microfiltration systems (2 plants) and coagulation/sedimentation/rapid sand filtration systems (3 plants) partially removed this fraction. None of the pre-treatment systems investigated totally removed colloidal TEP. Biopolymer analysis using LC-OCD showed consistency between colloidal TEP and polysaccharide removal by UF pre-treatment and further verified the presence of TEP in the RO feedwater. TEP deposition in the RO system was determined after measuring total TEP concentrations in the RO feed and concentrate. The TEP deposition factors and specific deposition rates indicate that TEP accumulation had occurred in all plants investigated. This observation was verified by an autopsy of RO modules from two RO plants. Further improvement and verification of the (modified) TEP method, in particular the calibration, is necessary so that it can be employed to investigate the role of TEP in the fouling of RO systems.

  18. Ceramic membrane as a pretreatment for reverse osmosis: Interaction between marine organic matter and metal oxides

    KAUST Repository

    Dramas, Laure

    2013-02-01

    Scaling and (bio)fouling phenomena can severely alter the performance of the reverse osmosis process during desalination of seawater. Pretreatments must be applied to efficiently remove particles, colloids, and also precursors of the organic fouling and biofouling. Ceramic membranes offer a lot of advantages for micro and ultrafiltration pretreatments because their initial properties can be recovered using more severe cleaning procedure. The study focuses on the interaction between metal oxides and marine organic matter. Experiments were performed at laboratory scale. The first series of experiments focus on the filtration of different fractions of natural organic matter and model compounds solutions on flat disk ceramic membranes (47 mm of diameter) characterized with different pore size and composition. Direct filtration experiments were conducted at 0.7 bar or 2 bars and at room temperature (20 ± 0.5 °C). The efficiency of backflush and alkaline cleaning were eval, and titanium oxides. Each metal oxide corresponds to a specific pore size for the disk ceramic membranes: 80, 60, and 30 nm. Different sizes of metal oxide particles are used to measure the impact of the surface area on the adsorption of the organic matter. Seawaters from the Arabian Gulf and from the Red Sea were collected during algal blooms. Cultures of algae were also performed in the laboratory and in cooperation with woods hole oceanographic institute. Solutions of algal exudates were obtained after a couple of weeks of cultivation followed by sonication. Solutions were successively filtered through GFF (0.7 lm) and 0.45 lm membrane filters before use. The dissolved organic carbon (DOC) concentration of final solution was between 1 and 4 mg/L and showed strong hydrophilic character. These various solutions were prepared with the objective to mimic the dissolved organic matter composition of seawater subjected to algal bloom. Characterization of the solutions of filtration experiments (feed

  19. Application of volume-retarded osmosis and low-pressure membrane hybrid process for water reclamation

    KAUST Repository

    Im, Sung-Ju

    2017-11-15

    A new concept of volume-retarded osmosis and low-pressure membrane (VRO-LPM) hybrid process was developed and evaluated for the first time in this study. Commercially available forward osmosis (FO) and ultrafiltration (UF) membranes were employed in a VRO-LPM hybrid process to overcome energy limitations of draw solution (DS) regeneration and production of permeate in the FO process. To evaluate its feasibility as a water reclamation process, and to optimize the operational conditions, cross-flow FO and dead-end mode UF processes were individually evaluated. For the FO process, a DS concentration of 0.15 g mL−1 of polysulfonate styrene (PSS) was determined to be optimal, having a high flux with a low reverse salt flux. The UF membrane with a molecular weight cut-off of 1 kDa was chosen for its high PSS rejection in the LPM process. As a single process, UF (LPM) exhibited a higher flux than FO, but this could be controlled by adjusting the effective membrane area of the FO and UF membranes in the VRO-LPM system. The VRO-LPM hybrid process only required a circulation pump for the FO process. This led to a decrease in the specific energy consumption of the VRO-LPM process for potable water production, that was similar to the single FO process. Therefore, the newly developed VRO-LPM hybrid process, with an appropriate DS selection, can be used as an energy efficient water production method, and can outperform conventional water reclamation processes.

  20. The use of microbial and chemical analyses to characterize the variations in fouling profile of seawater reverse osmosis (SWRO) membrane

    KAUST Repository

    Manes, Carmem Lara De O

    2013-01-01

    Biofouling of reverse osmosis (RO) membranes is one of the most common problems in desalinations plants reducing the efficiency of the water production process. The characterization of bacterial community composition from fouling layers as well as detailed analysis of surrounding chemical environment might reveal process specific bacterial groups/species that are involved in RO biofouling. In this study, advanced organics analytic methods (elemental analysis, FTIR, and ICP-OES) were combined with high-throughput 16S rRNA (pyro) sequencing to assess in parallel, the chemical properties and the active microbial community composition of SWRO membranes from a pilot desalination plant (MFT, Tarragona) in February 2011 and July 2011. Prefiltered ultrafiltration. waters fed SWRO membranes during third and fifth month of operation, respectively. SWRO samples were taken from three modules at different positions (first, fourth, and sixth) in order to investigate the spatial changes in fouling layers\\' chemical and microbiological composition. The overall assessment of chemical parameters revealed that fouling layers were mainly composed by bio and organic material (proteins and lipids). Ca and Fe were found to be the most abundant elements having an increasing concentration gradient according to the module position. Bacterial community composition of SWRO membranes is mostly represented by the Gammaproteobacteria class with interesting differences in genera/species spatial and temporal distribution. This preliminary result suggests that pretreatments and/or operational conditions might have selected different bacterial groups more adapted to colonize SWRO membranes. © 2013 Desalination Publications.

  1. In situ formation of silver nanoparticles on thin-film composite reverse osmosis membranes for biofouling mitigation

    KAUST Repository

    Ben-Sasson, Moshe

    2014-10-01

    The potential to incorporate silver nanoparticles (Ag-NPs) as biocides in membranes for water purification has gained much interest in recent years. However, a viable strategy for loading the Ag-NPs on the membrane remains challenging. This paper presents a novel, facile procedure for loading Ag-NPs on thin-film composite (TFC) reverse osmosis membranes. Reaction of silver salt with a reducing agent on the membrane surface resulted in uniform coverage of Ag-NPs, irreversibly bound to the membrane, as confirmed by XPS, TEM, and SEM analyses. Salt selectivity of the membrane as well its surface roughness, hydrophilicity, and zeta potential were not impacted by Ag-NP functionalization, while a slight reduction (up to 17%) in water permeability was observed. The formed Ag-NPs imparted strong antibacterial activity to the membrane, leading to reduction of more than 75% in the number of live bacteria attached to the membrane for three model bacteria strains. In addition, confocal microscopy analyses revealed that Ag-NPs significantly suppressed biofilm formation, with 41% reduction in total biovolume and significant reduction in EPS, dead, and live bacteria on the functionalized membrane. The simplicity of the method, the short reaction time, the ability to load the Ag-NPs on site, and the strong imparted antibacterial activity highlight the potential of this method in real-world RO membrane applications. © 2014 Elsevier Ltd.

  2. Reverse osmosis membrane composition, structure and performance modification by bisulphite, iron(III), bromide and chlorite exposure.

    Science.gov (United States)

    Ferrer, O; Gibert, O; Cortina, J L

    2016-10-15

    Reverse osmosis (RO) membrane exposure to bisulphite, chlorite, bromide and iron(III) was assessed in terms of membrane composition, structure and performance. Membrane composition was determined by Rutherford backscattering spectrometry (RBS) and membrane performance was assessed by water and chloride permeation, using a modified version of the solution-diffusion model. Iron(III) dosage in presence of bisulphite led to an autooxidation of the latter, probably generating free radicals which damaged the membrane. It comprised a significant raise in chloride passage (chloride permeation coefficient increased 5.3-5.1 fold compared to the virgin membrane under the conditions studied) rapidly. No major differences in terms of water permeability and membrane composition were observed. Nevertheless, an increase in the size of the network pores, and a raise in the fraction of aggregate pores of the polyamide (PA) layer were identified, but no amide bond cleavage was observed. These structural changes were therefore, in accordance with the transport properties observed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Effect of conventional chemical treatment on the microbial population in a biofouling layer of reverse osmosis systems.

    Science.gov (United States)

    Bereschenko, L A; Prummel, H; Euverink, G J W; Stams, A J M; van Loosdrecht, M C M

    2011-01-01

    The impact of conventional chemical treatment on initiation and spatiotemporal development of biofilms on reverse osmosis (RO) membranes was investigated in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The flow cells got the same feed (extensively pre-treated fresh surface water) and operational conditions (temperature, pressure and membrane flux) as the full-scale installation. With regular intervals both the full-scale RO membrane modules and the flow cells were cleaned using conventional chemical treatment. For comparison some flow cells were not cleaned. Sampling was done at different time periods of flow cell operation (i.e., 1, 5, 10 and 17 days and 1, 3, 6 and 12 months). The combination of molecular (FISH, DGGE, clone libraries and sequencing) and microscopic (field emission scanning electron, epifluorescence and confocal laser scanning microscopy) techniques made it possible to thoroughly analyze the abundance, composition and 3D architecture of the emerged microbial layers. The results suggest that chemical treatment facilitates initiation and subsequent maturation of biofilm structures on the RO membrane and feed-side spacer surfaces. Biofouling control might be possible only if the cleaning procedures are adapted to effectively remove the (dead) biomass from the RO modules after chemical treatment. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Beneficial phosphate recovery from reverse osmosis (RO) concentrate of an integrated membrane system using polymeric ligand exchanger (PLE).

    Science.gov (United States)

    Kumar, Manish; Badruzzaman, Mohammad; Adham, Samer; Oppenheimer, Joan

    2007-05-01

    Phosphorus (P) discharge to surface water is a major environmental problem. Wastewater treatment is targeted towards removal of this nutrient to prevent degradation of surface water. Integrated membrane systems (IMS) are increasingly being considered for wastewater reclamation, and provide excellent removal of P compounds. However, reverse osmosis (RO), which forms an integral part of these IMSs, concentrates most dissolved substances including P-species such as phosphates in the RO waste stream. In this study, removal of phosphate from this stream using polymeric ligand exchange (PLE) resins was investigated. Further, the possibility of phosphate recovery through struvite (MgNH(4)PO(4).6H(2)O) precipitation was tested. Struvite has been promoted as a slow release fertilizer in recent years. This study demonstrates that PLEs can be successfully used to remove phosphate from RO-concentrate, and to recover more than 85% of the adsorbed phosphorus from the exhausted media and precipitated as a beneficial product (struvite). The approach, presented in this study, suggests advantages of providing economic benefit from a waste product (RO) while avoiding phosphorus discharge to the environment.

  5. Novel reverse osmosis membranes composed of modified PVA/Gum Arabic conjugates: Biofouling mitigation and chlorine resistance enhancement.

    Science.gov (United States)

    Falath, Wail; Sabir, Aneela; Jacob, Karl I

    2017-01-02

    A novel crosslinked Poly (vinyl alcohol) (PVA) reverse osmosis (RO) thin film membrane conjugated with Gum Arabic (GA) with superb performance and features was synthesized for water desalination. RO membrane desalination parameters, such as hydrophilicity, surface roughness, water permeability, salt rejection, Chlorine resistance and biofouling resistance were evaluated using a dead end RO filtration unit. The incorporation of Pluronic F127 and the conjugation of Gum Arabic improved the overall RO performance of the membranes. This study has shown that the membrane PVA-GA-5 that contains 0.9wt% Gum Arabic provided excellent permeation, salt rejection, Chlorine and biofouling resistance and mechanical strength. The most remarkable result to arise from this research is that the overall RO performance enhancement has been achieved while utilizing PVA/Gum Arabic as a separation layer without the use of a substrate, which eliminates negative effects associated with the use of a substrate like internal concentration polarization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Fouling of a spiral-wound reverse osmosis membrane processing swine wastewater: effect of cleaning procedure on fouling resistance.

    Science.gov (United States)

    Camilleri-Rumbau, M S; Masse, L; Dubreuil, J; Mondor, M; Christensen, K V; Norddahl, B

    2016-01-01

    Swine manure is a valuable source of nitrogen, phosphorus and potassium. After solid-liquid separation, the resulting swine wastewater can be concentrated by reverse osmosis (RO) to produce a nitrogen-potassium rich fertilizer. However, swine wastewater has a high fouling potential and an efficient cleaning strategy is required. In this study, a semi-commercial farm scale RO spiral-wound membrane unit was fouled while processing larger volumes of swine wastewater during realistic cyclic operations over a 9-week period. Membrane cleaning was performed daily. Three different cleaning solutions, containing SDS, SDS+EDTA and NaOH were compared. About 99% of the fouling resistance could be removed by rinsing the membrane with water. Flux recoveries (FRs) above 98% were achieved for all the three cleaning solutions after cleaning. No significant differences in FR were found between the cleaning solutions. The NaOH solution thus is a good economical option for cleaning RO spiral-wound membranes fouled with swine wastewater. Soaking the membrane for 3 days in permeate water at the end of each week further improved the FR. Furthermore, a fouling resistance model for predicting the fouling rate, permeate flux decay and cleaning cycle periods based on processing time and swine wastewater conductivity was developed.

  7. Flow cytometric assessment of microbial abundance in the near-field area of seawater reverse osmosis concentrate discharge

    KAUST Repository

    Van Der Merwe, Riaan

    2014-06-01

    The discharge of concentrate and other process waters from seawater reverse osmosis (SWRO) plant operations into the marine environment may adversely affect water quality in the near-field area surrounding the outfall. The main concerns are the increase in salt concentration in receiving waters, which results in a density increase and potential water stratification near the outfall, and possible increases in turbidity, e.g., due to the discharge of filter backwash waters. Changes in ambient water quality may affect microbial abundance in the area, for example by hindering the photosynthesis process or disrupting biogenesis. It is widely accepted that marine biodiversity is lower in more extreme conditions, such as high salinity environments. As aquatic microbial communities respond very rapidly to changes in their environment, they can be used as indicators for monitoring ambient water quality. The objective of this study was to assess possible changes in microbial abundance as a result of concentrate discharge into the near-field area (<. 25. m) surrounding the outfall of the King Abdullah University of Science and Technology (KAUST) SWRO plant. Flow cytometric (FCM) analysis was conducted in order to rapidly determine microbial abundance on a single-cell level in 107 samples, taken by diving, from the discharge area, the intake area and two control sites. FCM analysis combined the measurement of distinct scatter of cells and particles, autofluorescence of cyanobacteria and algae, and fluorescence after staining of nucleic acids with SYBR® Green for a total bacterial count. The results indicate that changes in microbial abundance in the near-field area of the KAUST SWRO outfall are minor and appear to be the result of a dilution effect rather than a direct impact of the concentrate discharge. © 2014 Elsevier B.V.

  8. Carbon Dioxide Nucleation as a Novel Cleaning Method for Sodium Alginate Fouling Removal from Reverse Osmosis Membranes desalination

    KAUST Repository

    Alnajjar, Heba

    2017-05-01

    The use of Reverse osmosis (RO) membranes have been significantly increasing in water desalination, and the main operational obstacle in RO desalination plants is membrane fouling. Among other solutes, dissolved biopolymers, such as polysaccharides can lead to severe membrane fouling especially with the addition of calcium ions because of the complexation formation between the surface of membrane and foulants materials. However, this complexation can also take place in the feed bulk, resulting in foulants aggregates formation. Although there are some physical techniques that can maintain the membrane performance without reducing its lifetime, only chemical cleanings are still commonly used in RO plants. In this study, a novel cleaning method is proposed to restore the membrane performance by removing the deposited foulants without reducing the membrane lifetime. The cleaning method is based on using water saturated with dissolved CO2 gas, and its principle is based on producing spontaneous CO2 bubbles due to local pressure difference leading to nucleation of bubbles throughout the membrane surface, especially at nucleation sites, which improve the cleaning efficiency. Alginic acid sodium salt was used as a model of polysaccharides foulants in presence of different concentrations of NaCl and calcium ions aiming to enhance membrane fouling, and then CO2 cleaning solution efficiency, in terms flux recovery (FR), was tested under different operating conditions and compared to other cleaning methods. Average FR of 20%±3, 25%±3 and 80%±3 for MilliQ water, a cleaning solution at pH4, and CO2 solution at 6 bar, 0.17 m/s, and 23 ̊C ±0.2 for 6 minutes were obtained, respectively. The efficiency of this novel cleaning method was also compared to direct osmosis overnight, and the average flux was comparable (about 60%±3), though that the cleaning time was significantly different. Various calcium concentrations (0-10 mM) were added in the alginate solution to study the

  9. Effects of chemical agent injections on genotoxicity of wastewater in a microfiltration-reverse osmosis membrane process for wastewater reuse.

    Science.gov (United States)

    Tang, Fang; Hu, Hong-Ying; Wu, Qian-Yuan; Tang, Xin; Sun, Ying-Xue; Shi, Xiao-Lei; Huang, Jing-Jing

    2013-09-15

    With combined microfiltration (MF)/ultrafiltration (UF) and reverse osmosis (RO) process being widely used in municipal wastewater reclamation, RO concentrate with high level genotoxicity is becoming a potential risk to water environment. In this study, wastewater genotoxicity in a MF-RO process for municipal wastewater reclamation and also the effects of chemical agent injections were evaluated by SOS/umu genotoxicity test. The genotoxicity of RO concentrate ranged 500-559 μg 4-NQO (4-nitroquinoline-1-oxide)/L and 12-22 μg 4-NQO/mg DOC, was much higher than that of RO influent. Further research suggested that Kathon biocide was a key chemical agent associated with the genotoxicity increase. Kathon biocide used in RO system was highly genotoxic in vitro and Kathon biocide retained in RO system could contribute to a higher genotoxicity of RO concentrate. Hence, treatments for biocides before discharging are necessary. Chlorination of secondary effluent could significantly decrease the genotoxicity and increasing chlorine dosage could be an efficacious method to decrease the genotoxicity of RO concentrate. According to the result of the experiment, the dosage of chlorine in dual-membrane process could be set to about 2.5 mg Cl₂/L. The effect of antiscalant (2-phosphomobutane-1,2,4-tricarboxylic acid) was also investigated; it turned out to have no effect on genotoxicity. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Electrochemical oxidation of tramadol in low-salinity reverse osmosis concentrates using boron-doped diamond anodes.

    Science.gov (United States)

    Lütke Eversloh, Christian; Schulz, Manoj; Wagner, Manfred; Ternes, Thomas A

    2015-04-01

    The electrochemical treatment of low-salinity reverse osmosis (RO) concentrates was investigated using tramadol (100 μM) as a model substance for persistent organic contaminants. Galvanostatic degradation experiments using boron-doped diamond electrodes at different applied currents were conducted in RO concentrates as well as in ultra-pure water containing either sodium chloride or sodium sulfate. Kinetic investigations revealed a significant influence of in-situ generated active chlorine besides direct anodic oxidation. Therefore, tramadol concentrations decreased more rapidly at elevated chloride content. Nevertheless, reduction of total organic carbon (TOC) was found to be comparatively low, demonstrating that transformation rather than mineralization was taking place. Early stage product formation could be attributed to both direct and indirect processes, including demethylation, hydroxylation, dehydration, oxidative aromatic ring cleavage and halogenation reactions. The latter led to various halogenated derivatives and resulted in AOX (adsorbable organic halogens) formation in the lower mg/L-range depending on the treatment conditions. Characterisation of transformation products (TPs) was achieved via MS(n) experiments and additional NMR measurements. Based on identification and quantification of the main TPs in different matrices and on additional potentiostatic electrolysis, a transformation pathway was proposed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Partitioning of Alkali Metal Salts and Boric Acid from Aqueous Phase into the Polyamide Active Layers of Reverse Osmosis Membranes.

    Science.gov (United States)

    Wang, Jingbo; Kingsbury, Ryan S; Perry, Lamar A; Coronell, Orlando

    2017-02-21

    The partition coefficient of solutes into the polyamide active layer of reverse osmosis (RO) membranes is one of the three membrane properties (together with solute diffusion coefficient and active layer thickness) that determine solute permeation. However, no well-established method exists to measure solute partition coefficients into polyamide active layers. Further, the few studies that measured partition coefficients for inorganic salts report values significantly higher than one (∼3-8), which is contrary to expectations from Donnan theory and the observed high rejection of salts. As such, we developed a benchtop method to determine solute partition coefficients into the polyamide active layers of RO membranes. The method uses a quartz crystal microbalance (QCM) to measure the change in the mass of the active layer caused by the uptake of the partitioned solutes. The method was evaluated using several inorganic salts (alkali metal salts of chloride) and a weak acid of common concern in water desalination (boric acid). All partition coefficients were found to be lower than 1, in general agreement with expectations from Donnan theory. Results reported in this study advance the fundamental understanding of contaminant transport through RO membranes, and can be used in future studies to decouple the contributions of contaminant partitioning and diffusion to contaminant permeation.

  12. Fouling characteristics of reverse osmosis membranes at different positions of a full-scale plant for municipal wastewater reclamation.

    Science.gov (United States)

    Tang, Fang; Hu, Hong-Ying; Sun, Li-Juan; Sun, Ying-Xue; Shi, Na; Crittenden, John C

    2016-03-01

    Membrane fouling is an important shortcoming limiting the efficiency and wide application of reverse osmosis (RO) technology. In this paper, RO membranes in a full-scale municipal wastewater reclamation plant were autopsied. From the lead to tail position RO membranes in RO system, both of organic and inorganic matters on membranes reduced gradually. The higher ion products in RO concentrate didn't result in more serious inorganic scaling on the last position RO membranes, which was contrast with some other researches. Fe, Ca and Mg were major inorganic elements. Fe had a relatively low concentration in RO influent but the highest content on membranes. However, there was no specific pretreatment in terms of Fe removal. Ca and Mg scaling was controlled by the antiscalants injected. Organic fouling (75.0-84.5% of dry weights) was major problem on RO membranes due to the large amount of dissolved organic matters in secondary effluent as raw water. Hydrophilic acid (HIA, 48.0% of total DOC), hydrophobic acid (HOA, 23.6%) and hydrophobic neutral (HON, 19.0%) fraction was largest among the six fractions in RO influent, while HON (38.2-51.1%) and HOA (22.1-26.1%) tended to accumulate on membranes in higher quantities. Monitoring HON and HOA might help to forecast organic fouling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Diminished swelling of cross-linked aromatic oligoamide surfaces revealing a new fouling mechanism of reverse-osmosis membranes.

    Science.gov (United States)

    Ying, Wang; Kumar, Rajender; Herzberg, Moshe; Kasher, Roni

    2015-06-02

    Swelling of the active layer of reverse osmosis (RO) membranes has an important effect on permeate water flux. The effects of organic- and biofouling on the swelling of the RO membrane active layer and the consequent changes of permeate flux are examined here. A cross-linked aromatic oligoamide film that mimics the surface chemistry of an RO polyamide membrane was synthesized stepwise on gold-coated surfaces. Foulant adsorption to the oligoamide film and its swelling were measured with a quartz crystal microbalance, and the effects of fouling on the membrane's performance were evaluated. The foulants were extracellular polymeric substances (EPS) extracted from fouled RO membranes and organic compounds of ultrafiltration permeate (UFP) from a membrane bioreactor used to treat municipal wastewater. The adsorbed foulants affected the swelling of the cross-linked oligoamide film differently. EPS had little effect on the swelling of the oligoamide film, whereas UFP significantly impaired swelling. Permeate flux declined more rapidly under UFP fouling than it did under EPS. Foulant adsorption was shown to diminish swelling of the aromatic oligoamide surfaces. Among the already known RO membrane fouling mechanisms, a novel RO fouling mechanism is proposed, in which foulant-membrane interactions hinder membrane swelling and thus increase hydraulic resistance.

  14. Thermodynamic analysis of osmotic energy recovery at a reverse osmosis desalination plant.

    Science.gov (United States)

    Feinberg, Benjamin J; Ramon, Guy Z; Hoek, Eric M V

    2013-03-19

    Recent years have seen a substantial reduction of the specific energy consumption (SEC) in seawater reverse osmosis (RO) desalination due to improvements made in hydraulic energy recovery (HER) as well as RO membranes and related process technologies. Theoretically, significant potential for further reduction in energy consumption may lie in harvesting the high chemical potential contained in RO concentrate using salinity gradient power technologies. Herein, "osmotic energy recovery" (OER) is evaluated in a seawater RO plant that includes state-of-the-art RO membranes, plant designs, operating conditions, and HER technology. Here we assume the use of treated wastewater effluent as the OER dilute feed, which may not be available in suitable quality or quantity to allow operation of the coupled process. A two-stage OER configuration could reduce the SEC of seawater RO plants to well below the theoretical minimum work of separation for state-of-the-art RO-HER configurations with a breakeven OER CAPEX equivalent to 42% of typical RO-HER plant cost suggesting significant cost savings may also be realized. At present, there is no commercially viable OER technology; hence, the feasibility of using OER at seawater RO plants remains speculative, however attractive.

  15. Nuclide separation modeling through reverse osmosis membranes in radioactive liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Sik [KEPCO Engineering and Construction, Gimcheon (Korea, Republic of)

    2015-12-15

    The aim of this work is to investigate the transport mechanism of radioactive nuclides through the reverse osmosis (RO) membrane and to estimate its effectiveness for nuclide separation from radioactive liquid waste. An analytical model is developed to simulate the RO separation, and a series of experiments are set up to confirm its estimated separation behavior. The model is based on the extended Nernst-Plank equation, which handles the convective flux, diffusive flux, and electromigration flux under electroneutrality and zero electric current conditions. The distribution coefficient which arises due to ion interactions with the membrane material and the electric potential jump at the membrane interface are included as boundary conditions in solving the equation. A high Peclet approximation is adopted to simplify the calculation, but the effect of concentration polarization is included for a more accurate prediction of separation. Cobalt and cesium are specifically selected for the experiments in order to check the separation mechanism from liquid waste composed of various radioactive nuclides and nonradioactive substances, and the results are compared with the estimated cobalt and cesium rejections of the RO membrane using the model. Experimental and calculated results are shown to be in excellent agreement. The proposed model will be very useful for the prediction of separation behavior of various radioactive nuclides by the RO membrane.

  16. Performance Evaluation of Reverse Osmosis Technology for Selected Antibiotics Removal from Synthetic Pharmaceutical Wastewater

    Directory of Open Access Journals (Sweden)

    Mitra Gholami

    2012-12-01

    Full Text Available This study addresses the possibility for low pressure reverse osmosis membrane (RE 2521, CSM process to serve as an alternative to remove selected antibiotics (ampicillin and amoxicillin from synthetic wastewater by changing operating conditions such as pH = 3, 6.5 and 10; Pressure = 9, 11 and13 (bar; antibiotic concentration = 10, 255and 500(mg/L, and temperature = 20, 30 and 40°C. The experiment was designed based on Box-benken, which is a Response Surface methodology design (RSM, using Design Expert software. The concentration of antibiotics was measured by applying a UV-spectrophotometer (Cecil, at the wavelength of 254 nm. Results showed a range ofrejection percentage from 73.52% to 99.36% and 75.1% to 98.8%, for amoxicillin and ampicillin, respectively.Considering the solute rejections and the membrane porosity show that the prevailing rejection mechanism of the examined antibiotics by the membrane was the size exclusion effect. The permeate flux for both of the antibiotics was 12–18.73 L/m2.h. Although the permeate flux and antibiotic rejection are influenced by operating pressure, pH,and temperature individually, the interaction between operating parameters did not have noticeable effects. According to the results obtained in this study, the application of RO membrane is recommended for the selected antibiotics to be removed to a considerable degree (up to 95%.

  17. Performance evaluation of reverse osmosis technology for selected antibiotics removal from synthetic pharmaceutical wastewater

    Science.gov (United States)

    2012-01-01

    This study addresses the possibility for low pressure reverse osmosis membrane (RE 2521, CSM) process to serve as an alternative to remove selected antibiotics (ampicillin and amoxicillin) from synthetic wastewater by changing operating conditions such as pH = 3, 6.5 and 10; Pressure = 9, 11 and13 (bar); antibiotic concentration = 10, 255 and 500(mg/L), and temperature = 20, 30 and 40°C. The experiment was designed based on Box-benken, which is a Response Surface methodology design (RSM), using Design Expert software. The concentration of antibiotics was measured by applying a UV-spectrophotometer (Cecil), at the wavelength of 254 nm. Results showed a range of rejection percentage from 73.52% to 99.36% and 75.1% to 98.8%, for amoxicillin and ampicillin, respectively. Considering the solute rejections and the membrane porosity show that the prevailing rejection mechanism of the examined antibiotics by the membrane was the size exclusion effect. The permeate flux for both of the antibiotics was 12–18.73 L/m2.h. Although the permeate flux and antibiotic rejection are influenced by operating pressure, pH, and temperature individually, the interaction between operating parameters did not have noticeable effects. According to the results obtained in this study, the application of RO membrane is recommended for the selected antibiotics to be removed to a considerable degree (up to 95%). PMID:23369431

  18. Control of biofouling on reverse osmosis polyamide membranes modified with biocidal nanoparticles and antifouling polymer brushes

    KAUST Repository

    Rahaman, Md. Saifur

    2014-01-01

    Thin-film composite (TFC) polyamide reverse osmosis (RO) membranes are prone to biofouling due to their inherent physicochemical surface properties. In order to address the biofouling problem, we have developed novel surface coatings functionalized with biocidal silver nanoparticles (AgNPs) and antifouling polymer brushes via polyelectrolyte layer-by-layer (LBL) self-assembly. The novel surface coating was prepared with polyelectrolyte LBL films containing poly(acrylic acid) (PAA) and poly(ethylene imine) (PEI), with the latter being either pure PEI or silver nanoparticles coated with PEI (Ag-PEI). The coatings were further functionalized by grafting of polymer brushes, using either hydrophilic poly(sulfobetaine) or low surface energy poly(dimethylsiloxane) (PDMS). The presence of both LBL films and sulfobetaine polymer brushes at the interface significantly increased the hydrophilicity of the membrane surface, while PDMS brushes lowered the membrane surface energy. Overall, all surface modifications resulted in significant reduction of irreversible bacterial cell adhesion. In microbial adhesion tests with E. coli bacteria, a normalized cell adhesion in the range of only 4 to 16% on the modified membrane surfaces was observed. Modified surfaces containing silver nanoparticles also exhibited strong antimicrobial activity. Membranes coated with LBL films of PAA/Ag-PEI achieved over 95% inactivation of bacteria attached to the surface within 1 hour of contact time. Both the antifouling and antimicrobial results suggest the potential of using these novel surface coatings in controlling the fouling of RO membranes. © The Royal Society of Chemistry 2014.

  19. Quorum quenching bacteria can be used to inhibit the biofouling of reverse osmosis membranes.

    Science.gov (United States)

    Oh, Hyun-Suk; Tan, Chuan Hao; Low, Jiun Hui; Rzechowicz, Miles; Siddiqui, Muhammad Faisal; Winters, Harvey; Kjelleberg, Staffan; Fane, Anthony G; Rice, Scott A

    2017-04-01

    Over the last few decades, significant efforts have concentrated on mitigating biofouling in reverse osmosis (RO) systems, with a focus on non-toxic and sustainable strategies. Here, we explored the potential of applying quorum quenching (QQ) bacteria to control biofouling in a laboratory-scale RO system. For these experiments, Pantoea stewartii was used as a model biofilm forming organism because it was previously shown to be a relevant wastewater isolate that also forms biofilms in a quorum sensing (QS) dependent fashion. A recombinant Escherichia coli strain, which can produce a QQ enzyme, was first tested in batch biofilm assays and significantly reduced biofilm formation by P. stewartii. Subsequently, RO membranes were fouled with P. stewartii and the QQ bacterium was introduced into the RO system using two different strategies, direct injection and immobilization within a cartridge microfilter. When the QQ bacterial cells were directly injected into the system, N-acylhomoserine lactone signals were degraded, resulting in the reduction of biofouling. Similarly, the QQ bacteria controlled biofouling when immobilized within a microfilter placed downstream of the RO module to remove QS signals circulating in the system. These results demonstrate the proof-of-principle that QQ can be applied to control biofouling of RO membranes and may be applicable for use in full-scale plants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Physiology and genetic traits of reverse osmosis membrane biofilms: a case study with Pseudomonas aeruginosa.

    Science.gov (United States)

    Herzberg, Moshe; Elimelech, Menachem

    2008-02-01

    Biofilm formation of Pseudomonas aeruginosa on the surface of a reverse osmosis (RO) membrane was studied using a synthetic wastewater medium to simulate conditions relevant to reclamation of secondary wastewater effluent. P. aeruginosa biofilm physiology and spatial activity were analyzed following growth on the membrane using a short-life green fluorescent protein derivative expressed in a growth-dependent manner. As a consequence of the limiting carbon source prevailing in the suspended culture of the RO unit, a higher distribution of active cells was observed in the biofilm close to the membrane surface, likely due to the higher nutrient levels induced by concentration polarization effects. The faster growth of the RO-sessile cells compared to the planktonic cells in the RO unit was reflected by the transcriptome of the two cultures analyzed with DNA microarrays. In contrast to the findings recently reported in gene expression studies of P. aeruginosa biofilms, in the RO system, genes related to stress, adaptation, chemotaxis and resistance to antibacterial agents were induced in the planktonic cells. In agreement with the findings of previous P. aeruginosa biofilm studies, motility- and attachment-related genes were repressed in the RO P. aeruginosa biofilm. Supported by the microarray data, an increase in both motility and chemotaxis phenotypes was observed in the suspended cells. The increase in nutrient concentration in close proximity to the membrane is suggested to enhance biofouling by chemotaxis response of the suspended cells and their swimming toward the membrane surface.

  1. Feasibility of supercritical CO₂ treatment for controlling biofouling in the reverse osmosis process.

    Science.gov (United States)

    Mun, Sungmin; Baek, Youngbin; Kim, Cholin; Lee, Youn-Woo; Yoon, Jeyong

    2012-01-01

    Physical cleaning and/or chemical cleaning have been generally used to control biofouling in the reverse osmosis (RO) process. However, conventional membrane cleaning methods to control biofouling are limited due to the generation of by-products and the potential for damage to the RO membranes. In this study, supercritical carbon dioxide (SC CO(2)) treatment, an environmentally friendly technique, was introduced to control biofouling in the RO process. SC CO(2) (100 bar at 35°C) treatment was performed after biofouling was induced on a commercial RO membrane using Pseudomonas aeruginosa PA01 GFP as a model bacterial strain. P. aeruginosa PA01 GFP biofilm cells were reduced on the RO membrane by >8 log within 30 min, and the permeate flux was sufficiently recovered in a laboratory-scale RO membrane system without any significant damage to the RO membrane. These results suggest that SC CO(2) treatment is a promising alternative membrane cleaning technique for biofouling in the RO process.

  2. Performance evaluation of reverse osmosis technology for selected antibiotics removal from synthetic pharmaceutical wastewater

    Directory of Open Access Journals (Sweden)

    Gholami Mitra

    2012-12-01

    Full Text Available Abstract This study addresses the possibility for low pressure reverse osmosis membrane (RE 2521, CSM process to serve as an alternative to remove selected antibiotics (ampicillin and amoxicillin from synthetic wastewater by changing operating conditions such as pH = 3, 6.5 and 10; Pressure = 9, 11 and13 (bar; antibiotic concentration = 10, 255 and 500(mg/L, and temperature = 20, 30 and 40°C. The experiment was designed based on Box-benken, which is a Response Surface methodology design (RSM, using Design Expert software. The concentration of antibiotics was measured by applying a UV-spectrophotometer (Cecil, at the wavelength of 254 nm. Results showed a range of rejection percentage from 73.52% to 99.36% and 75.1% to 98.8%, for amoxicillin and ampicillin, respectively. Considering the solute rejections and the membrane porosity show that the prevailing rejection mechanism of the examined antibiotics by the membrane was the size exclusion effect. The permeate flux for both of the antibiotics was 12–18.73 L/m2.h. Although the permeate flux and antibiotic rejection are influenced by operating pressure, pH, and temperature individually, the interaction between operating parameters did not have noticeable effects. According to the results obtained in this study, the application of RO membrane is recommended for the selected antibiotics to be removed to a considerable degree (up to 95%.

  3. Composition and variability of biofouling organisms in seawater reverse osmosis desalination plants.

    Science.gov (United States)

    Zhang, Minglu; Jiang, Sunny; Tanuwidjaja, Dian; Voutchkov, Nikolay; Hoek, Eric M V; Cai, Baoli

    2011-07-01

    Seawater reverse osmosis (SWRO) membrane biofouling remains a common challenge in the desalination industry, but the marine bacterial community that causes membrane fouling is poorly understood. Microbial communities at different stages of treatment processes (intake, cartridge filtration, and SWRO) of a desalination pilot plant were examined by both culture-based and culture-independent approaches. Bacterial isolates were identified to match the genera Shewanella, Alteromonas, Vibrio, and Cellulophaga based on 16S rRNA gene sequencing analysis. The 16S rRNA gene clone library of the SWRO membrane biofilm showed that a filamentous bacterium, Leucothrix mucor, which belongs to the gammaproteobacteria, accounted for nearly 30% of the clone library, while the rest of the microorganisms (61.2% of the total clones) were related to the alphaproteobacteria. 16S rRNA gene terminal restriction fragment length polymorphism (T-RFLP) analysis indicated that bacteria colonizing the SWRO membrane represented a subportion of microbes in the source seawater; however, they were quite different from those colonizing the cartridge filter. The examination of five SWRO membranes from desalination plants located in different parts of the world showed that although the bacterial communities from the membranes were not identical to each other, some dominant bacteria were commonly observed. In contrast, bacterial communities in source seawater were significantly different based on location and season. Microbial profiles from 14 cartridge filters collected from different plants also revealed spatial trends.

  4. Comparative pyrosequencing analysis of bacterial community change in biofilm formed on seawater reverse osmosis membrane.

    Science.gov (United States)

    Kim, In S; Lee, Jinwook; Kima, Sung-Jo; Yu, Hye-Weon; Jang, Am

    2014-01-01

    The change in bacterial community structure induced by bacterial competition and succession was investigated during seawater reverse osmosis (SWRO) in order to elucidate a possible link between the bacterial consortium on SWRO membranes and biofouling. To date, there has been no definitive characterization of the microbial diversity in SWRO in terms of distinguishing time-dependent changes in the richness or abundance of bacterial species. For bacterial succession within biofilms on the membrane surface, SWRO using a cross-flow filtration membrane test unit was operated for 5 and 100h, respectively. As results of the pyrosequencing analysis, bacterial communities differed considerably among seawater and the 5 and 100 h samples. From a total of 33,876 pyrosequences (using a 95% sequence similarity), there were less than 1% of shared species, confirming the influence of the operational time factor and lack of similarity of these communities. During SWRO operation, the abundance of Pseudomonas stutzeri BBSPN3 (GU594474) belonging to gamma-Proteobacteria suggest that biofouling of SWRO membrane might be driven by the dominant influence of a specific species. In addition, among the bacterial competition of five bacterial species (Pseudomonas aeruginosa, Bacillus sp., Rhodobacter sp., Flavobacterium sp., and Mycobacterium sp.) competing for bacterial colonization on the SWRO membrane surfaces, it was exhibited that Bacillus sp. was the most dominant. The dominant influences ofPseudomonas sp. and Bacillus sp. on biofouling during actual SWRO is decisive depending on higher removal efficiency of the seawater pretreatment.

  5. Composition and Variability of Biofouling Organisms in Seawater Reverse Osmosis Desalination Plants ▿ †

    Science.gov (United States)

    Zhang, Minglu; Jiang, Sunny; Tanuwidjaja, Dian; Voutchkov, Nikolay; Hoek, Eric M. V.; Cai, Baoli

    2011-01-01

    Seawater reverse osmosis (SWRO) membrane biofouling remains a common challenge in the desalination industry, but the marine bacterial community that causes membrane fouling is poorly understood. Microbial communities at different stages of treatment processes (intake, cartridge filtration, and SWRO) of a desalination pilot plant were examined by both culture-based and culture-independent approaches. Bacterial isolates were identified to match the genera Shewanella, Alteromonas, Vibrio, and Cellulophaga based on 16S rRNA gene sequencing analysis. The 16S rRNA gene clone library of the SWRO membrane biofilm showed that a filamentous bacterium, Leucothrix mucor, which belongs to the gammaproteobacteria, accounted for nearly 30% of the clone library, while the rest of the microorganisms (61.2% of the total clones) were related to the alphaproteobacteria. 16S rRNA gene terminal restriction fragment length polymorphism (T-RFLP) analysis indicated that bacteria colonizing the SWRO membrane represented a subportion of microbes in the source seawater; however, they were quite different from those colonizing the cartridge filter. The examination of five SWRO membranes from desalination plants located in different parts of the world showed that although the bacterial communities from the membranes were not identical to each other, some dominant bacteria were commonly observed. In contrast, bacterial communities in source seawater were significantly different based on location and season. Microbial profiles from 14 cartridge filters collected from different plants also revealed spatial trends. PMID:21551282

  6. Nuclide separation modeling through reverse osmosis membranes in radioactive liquid waste

    Directory of Open Access Journals (Sweden)

    Byung-Sik Lee

    2015-12-01

    Full Text Available The aim of this work is to investigate the transport mechanism of radioactive nuclides through the reverse osmosis (RO membrane and to estimate its effectiveness for nuclide separation from radioactive liquid waste. An analytical model is developed to simulate the RO separation, and a series of experiments are set up to confirm its estimated separation behavior. The model is based on the extended Nernst–Plank equation, which handles the convective flux, diffusive flux, and electromigration flux under electroneutrality and zero electric current conditions. The distribution coefficient which arises due to ion interactions with the membrane material and the electric potential jump at the membrane interface are included as boundary conditions in solving the equation. A high Peclet approximation is adopted to simplify the calculation, but the effect of concentration polarization is included for a more accurate prediction of separation. Cobalt and cesium are specifically selected for the experiments in order to check the separation mechanism from liquid waste composed of various radioactive nuclides and nonradioactive substances, and the results are compared with the estimated cobalt and cesium rejections of the RO membrane using the model. Experimental and calculated results are shown to be in excellent agreement. The proposed model will be very useful for the prediction of separation behavior of various radioactive nuclides by the RO membrane.

  7. Effect of different commercial feed spacers on biofouling of reverse osmosis membrane systems: A numerical study

    KAUST Repository

    Bucs, Szilard

    2014-06-01

    Feed spacers and hydrodynamics have been found relevant for the impact of biofouling on performance in reverse osmosis (RO) and nanofiltration (NF) membrane systems.The objectives of this study on biofouling development were to determine the impact of (i) linear flow velocity and bacterial cell load, (ii) biomass location and (iii) various feed spacer geometries as applied in practice as well as a modified geometry spacer.A three-dimensional mathematical model for biofouling of feed spacer channels including hydrodynamics, solute mass transport and biofilm formation was developed in COMSOL Multiphysics and MATLAB software.Results of this study indicate that the feed channel pressure drop increase caused by biofilm formation can be reduced by using thicker and/or modified feed spacer geometry and/or a lower flow rate in the feed channel. The increase of feed channel pressure drop by biomass accumulation is shown to be strongly influenced by the location of biomass. Results of numerical simulations are in satisfactory agreement with experimental data, indicating that this micro-scale mechanistic model is representative for practice. The developed model can help to understand better the biofouling process of spiral-wound RO and NF membrane systems and to develop strategies to reduce and control biofouling. © 2013 Elsevier B.V.

  8. Adsorption of phosphonate antiscalant from reverse osmosis membrane concentrate onto granular ferric hydroxide.

    Science.gov (United States)

    Boels, Luciaan; Keesman, Karel J; Witkamp, Geert-Jan

    2012-09-04

    Adsorptive removal of antiscalants offers a promising way to improve current reverse osmosis (RO) concentrate treatment processes and enables the reuse of the antiscalant in the RO desalination process. This work investigates the adsorption and desorption of the phosphonate antiscalant nitrilotris(methylenephosphonic acid) (NTMP) from RO membrane concentrate onto granular ferric hydroxide (GFH), a material that consists predominantly of akaganéite. The kinetics of the adsorption of NTMP onto GFH was predicted fairly well with two models that consider either combined film-pore or combined film-surface diffusion as the main mechanism for mass transport. It is also demonstrated that NTMP is preferentially adsorbed over sulfate by GFH at pH 7.85. The presence of calcium causes a transformation in the equilibrium adsorption isotherm from a Langmuir type to a Freundlich type with much higher adsorption capacities. Furthermore, calcium also increases the rate of adsorption substantially. GFH is reusable after regeneration with sodium hydroxide solution, indicating that NTMP can be potentially recovered from the RO concentrate. This work shows that GFH is a promising adsorbent for the removal and recovery of NTMP antiscalant from RO membrane concentrates.

  9. Impacts of operating conditions on reverse osmosis performance of pretreated olive mill wastewater.

    Science.gov (United States)

    Ochando-Pulido, J M; Rodriguez-Vives, S; Hodaifa, G; Martinez-Ferez, A

    2012-10-01

    Management of the effluent from the olive oil industry is of capital importance nowadays, especially in the Mediterranean countries. Most of the scarce existing studies concerning olive mill wastewater (OMW) treatment by means of membrane processes not only do fix their aims simply on achieving irrigation standards, but lack suitable pretreatments against deleterious fouling issues. With the target of achieving the parametric requirements for public waterways discharge or even for reuse in the production process, a bench-scale study was undertaken to evaluate the feasibility of a thin-film composite reverse osmosis (RO) membrane (polyamide/polysulfone) for the purification of OMW. Previously, OMW was pretreated by means of chemical oxidation based on Fenton's reagent, flocculation-sedimentation and biosorption through olive stones. Impacts of the main operating parameters on permeate flux and pollutants rejection of the RO process, as well as fouling on the membrane surface, were examined for removing the significant ionic concentration and remaining organic matter load of the pretreated OMW. Combining operating parameters adequately in a semibatch operating regime ensured high and sustainable permeate flux, yielding over 99.4% and 98.5% removal efficiencies for the chemical oxygen demand and ionic content respectively, as well as complete rejection of phenols, iron and suspended solids. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Integrated Wireless Monitoring and Control System in Reverse Osmosis Membrane Desalination Plants

    Directory of Open Access Journals (Sweden)

    Al Haji Ahmad

    2015-01-01

    Full Text Available The operational processes of the Reverse Osmosis (RO membrane desalination plants require continuous monitoring through the constant attendance of operators to ensure proper productivity and minimize downtime and prevent membrane failure. Therefore, the plant must be equipped with a control system that monitors and controls the operational variables. Monitoring and controlling the affecting parameters are critical to the evaluation of the performance of the desalination plant, which will help the operator find and resolve problems immediately. Therefore, this paper was aimed at developing an RO unit by utilizing a wireless sensor network (WSN system. Hence, an RO pilot plant with a feed capacity of 1.2 m3/h was utilized, commissioned, and tested in Kuwait to assess and verify the performance of the integrated WSN in RO membrane desalination system. The investigated system allowed the operators to remotely monitor the operational process of the RO system. The operational data were smoothly recorded and monitored. Furthermore, the technical problems were immediately determined, which reduced the time and effort in rectifying the technical problems relevant to the RO performance. The manpower requirements of such treatment system were dramatically reduced by about 50%. Based on a comparison between manual and wireless monitoring operational processes, the availability of the integrated RO unit with a wireless monitoring was increased by 10%

  11. Production of grape juice powder obtained by freeze-drying after concentration by reverse osmosis

    Directory of Open Access Journals (Sweden)

    Poliana Deyse Gurak

    2013-12-01

    Full Text Available This study aimed to evaluate the freeze-drying process for obtaining grape juice powder by reverse osmosis using 50% grape juice pre-concentrated (28.5 °Brix and 50% hydrocolloids (37.5% maltodextrin and 12.5% arabic gum. The morphology of the glassy food showed the absence of crystalline structure, which was the amorphous wall that protected the contents of the powder. The samples were stored in clear and dark containers at room temperature, evaluated for their physical (X-ray diffraction for 65 days and chemical (polyphenol content stability for 120 days. During the storage time in plastic vessels, samples remained physically stable (amorphous and the phenolic concentration was constant, indicating the potentiality of this technique to obtain a stable product with a high concentration of phenolic compounds. Therefore, the freeze-drying process promoted the encapsulation of concentrated grape juice increasing its stability and shelf life, as well as proving to be an applicable process to food industry

  12. Selective removal of photocatalytic non-degradable fluorosurfactants from reverse osmosis concentrate.

    Science.gov (United States)

    Lin, Xuan Hao; Sriramulu, Deepa; Li, Sam Fong Yau

    2015-01-01

    Recently photocatalytic treatment of municipal reverse osmosis concentrate (ROC) has drawn increasing attention due to its relatively high efficiency and low cost. However, photocatalytic reactions by commercially available TiO₂ are not able to degrade fluorosurfactants in the ROC sample due to the absence of photoreactive groups in these compounds. Here we investigated adsorption and coagulation methods and their efficiencies in removing fluorosurfactants. The analysis and characterization methods included mass spectrometry (LC-QToF), total organic carbon (TOC), fluorescence & UV–Visible spectra, SEM, IR, N2 sorption, zeta potential, and elemental analysis. Ferric chloride (FER) coagulation was found to be quite efficient in removing fluorosurfactants, while powdered activated carbon (PAC) adsorption was inefficient. The FER pre-treatment process was found to perform better than the post-treatment process in removing the fluorosurfactants. FER selectively removed the bulky fluorosurfactants with long branches but not the slim ones with short or no branches. At a concentration of 10.60 mM, FER could efficiently remove 62.19% fluorosurfactants in total from the ROC sample. The applicability of Freundlich and Langmuir models for the adsorption processes was also investigated. FER was able to remove fluorosurfactant while PAC unable. While the PAC removal mechanism was adsorption, the FER coagulation mechanism was far more complicated.

  13. Reverse osmosis concentrate treatment via a PAC-MF accumulative countercurrent adsorption process.

    Science.gov (United States)

    Zhao, Chunxia; Gu, Ping; Cui, Hangyu; Zhang, Guanghui

    2012-01-01

    Organic pollutants in reverse osmosis (RO) concentrates from wastewater reclamation are mainly comprised of low molecular weight biorefractory compounds. Generally, advanced oxidation methods for oxidizing these organics require a relatively high level of energy consumption. In addition, conventional adsorption removal methods require a large dose of activated carbon. However, the dose can be reduced if its full adsorption capacity can be used. Therefore, the combined technology of powdered activated carbon (PAC) adsorption and microfiltration (MF) membrane filtration was studied to develop a countercurrent two-stage adsorption process. A PAC accumulative adsorption prediction method was proposed based on the verification of a PAC multi-stage adsorption capacity equation. Moreover, the prediction method was amended for a more accurate prediction of the effluent quality because adsorption isotherm constants were affected by the initial adsorbate concentration. The required PAC dose for the accumulative countercurrent two-stage adsorption system was 0.6 g/L, whereas that of the conventional adsorption process was 1.05 g/L when the dilution factor(F) was 0.1 and the COD and DOC removal rates were set to 70% and 68.1%, respectively. Organic pollutants were satisfactorily removed with less consumption of PAC. Effluent from this combined technology can be further reclaimed by an RO process to improve the overall recovery rate to between 91.0% and 93.8% with both economic and environmental benefits. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Effect of membrane bioreactor solids retention time on reverse osmosis membrane fouling for wastewater reuse.

    Science.gov (United States)

    Farias, Elizabeth L; Howe, Kerry J; Thomson, Bruce M

    2014-02-01

    The effect of the solids retention time (SRT) in a membrane bioreactor (MBR) on the fouling of the membranes in a subsequent reverse osmosis (RO) process used for wastewater reuse was studied experimentally using a pilot-scale treatment system. The MBR-RO pilot system was fed effluent from the primary clarifiers at a large municipal wastewater treatment plant. The SRT in the MBRs was adjusted to approximately 2, 10, and 20 days in three experiments. The normalized specific flux through the MBR and RO membranes was evaluated along with inorganic and organic constituents in the influent and effluent of each process. Increasing the SRT in the MBR led to an increase in the removal of bulk DOC, protein, and carbohydrates, as has been observed in previous studies. Increasing the SRT led to a decrease in the fouling of the MBR membranes, which is consistent with previous studies. However, the opposite trend was observed for fouling of the RO membranes; increasing the SRT of the MBR resulted in increased fouling of the RO membranes. These results indicate that the constituents that foul MBR membranes are not the same as those that foul RO membranes; to be an RO membrane foulant in a MBR-RO system, the constituents must first pass through the MBR membranes without being retained. Thus, an intermediate value of SRT may be best choice of operating conditions in an MBR when the MBR is followed by RO for wastewater reuse. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Multi-Response Optimization of Process Parameters for Imidacloprid Removal by Reverse Osmosis Using Taguchi Design.

    Science.gov (United States)

    Genç, Nevim; Doğan, Esra Can; Narcı, Ali Oğuzhan; Bican, Emine

    2017-05-01

      In this study, a multi-response optimization method using Taguchi's robust design approach is proposed for imidacloprid removal by reverse osmosis. Tests were conducted with different membrane type (BW30, LFC-3, CPA-3), transmembrane pressure (TMP = 20, 25, 30 bar), volume reduction factor (VRF = 2, 3, 4), and pH (3, 7, 11). Quality and quantity of permeate are optimized with the multi-response characteristics of the total dissolved solid (TDS), conductivity, imidacloprid, and total organic carbon (TOC) rejection ratios and flux of permeate. The optimized conditions were determined as membrane type of BW30, TMP 30 bar, VRF 3, and pH 11. Under these conditions, TDS, conductivity, imidacloprid, and TOC rejections and permeate flux were 97.50 97.41, 97.80, 98.00% and 30.60 L/m2·h, respectively. Membrane type was obtained as the most effective factor; its contribution is 64%. The difference between the predicted and observed value of multi-response signal/noise (MRSN) is within the confidence interval.

  16. Effect of gamma irradiation at intermediate doses on the performance of reverse osmosis membranes

    Science.gov (United States)

    Combernoux, Nicolas; Labed, Véronique; Schrive, Luc; Wyart, Yvan; Carretier, Emilie; Moulin, Philippe

    2016-07-01

    The goal of this study is to explain the degradation of Polyamide (PA) composite reverse osmosis membrane (RO) in function of the irradiation dose. Irradiations were performed with a gamma 60Co source in wet conditions and under oxygen atmosphere. For different doses of 0.2 and 0.5 MGy with a constant dose rate of 0.5 kGy h-1, RO membranes performances (NaCl retention, permeability) were studied before and after irradiation. ATR-FTIR, ion chromatography and gas chromatography were used to characterize structural modification. Results showed that the permeability of RO membranes irradiated at 0.2 MGy exhibited a small decrease, related to scissions of the PVA coating. However, retention did not change at this dose. At 0.5 MGy, permeability showed a large increase of a factor around 2 and retention began to decrease from 99% to 95%. Chromatography measurements revealed a strong link between permselectivity properties variation, ion leakage and oxygen consumption. Add to ATR-FTIR observations, these results emphasized that the cleavages of amide and ester bonds were observed at 0.5 MGy, more precisely the loss of hydrogen bonds between polyamide chains. By different analysis, modifications of the polysulfone layer occur until a dose of 0.2 MGy.

  17. Performance of electrodialysis reversal and reverse osmosis for reclaiming wastewater from high-tech industrial parks in Taiwan: A pilot-scale study.

    Science.gov (United States)

    Yen, Feng-Chi; You, Sheng-Jie; Chang, Tien-Chin

    2017-02-01

    Wastewater reclamation is considered an absolute necessity in Taiwan, as numerous industrial parks experience water shortage. However, the water quality of secondary treated effluents from sewage treatment plants generally does not meet the requirements of industrial water use because of the high inorganic constituents. This paper reports experimental data from a pilot-plant study of two treatment processes-(i) fiber filtration (FF)-ultrafiltration (UF)-reverse osmosis (RO) and (ii) sand filtration (SF)-electrodialysis reversal (EDR)-for treating industrial high conductivity effluents from the Xianxi wastewater treatment plant in Taiwan. The results demonstrated that FF-UF was excellent for turbidity removal and it was a suitable pretreatment process for RO. The influence of two membrane materials on the operating characteristics and process stability of the UF process was determined. The treatment performance of FF-UF-RO was higher than that of SF-EDR with an average desalination rate of 97%, a permeate conductivity of 272.7 ± 32.0, turbidity of 0.183 ± 0.02 NTU and a chemical oxigen demand of plant of 4000 m3/d capacity revealed that using FF-UF-RO had a lower treatment cost than using SF-EDR, which required activated carbon filtration as a post treatment process. On the basis of the results in this study, the FF-UF-RO system is recommended as a potential process for additional applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Study of Separation and Fouling of Reverse Osmosis Membranes during Model Hydrolysate Solution Filtration

    Science.gov (United States)

    Rahni, Mohamed; Marinova, Mariya; Chadjaa, Hassan; Savadogo, Oumarou

    2017-01-01

    Prehydrolysate, a dilute solution consisting mainly of pentoses, hexoses, and lesser quantities of organic acids, furfural and phenolics, is generated in the Kraft dissolving pulp process. An obstacle facing the valorization of the solution in hemicellulose biorefineries, by conversion of the sugars into bioproducts such as furfural, is the low sugar concentration. Membrane filtration is typically proposed in several hemicellulose based biorefineries for concentrating the solution, although they are usually generated using different wood species, pretreatment methods, and operating conditions. However, the chemical composition of the solutions is generally not considered. Also, the combined effect of composition and operating conditions is rarely investigated for biorefinery applications. The purpose of this work was to determine the impact of the prehydrolysate composition and operating parameters on the component separation and permeate flux during membrane filtration. Using model prehydrolysate solutions, two commercial reverse osmosis (RO) membranes were screened, and one was selected for use, based on its higher sugar and acetic acid retention. A Taguchi L18 experimental design array was then applied to determine the dominant parameters and limiting factors. Results showed that the feed pressure and temperature have the highest impact on permeate flux, but the least effect on sugar retention. Further experiments to quantify flux decline, due to fouling and osmotic pressure, showed that furfural has the highest membrane fouling tendency, and can limit the lifetime of the membrane. Regeneration of the membrane by cleaning with a sodium hydroxide solution is also effective for reversing fouling. It has been demonstrated that RO can efficiently and sustainably concentrate wood prehydrolysate. PMID:29244761

  19. Arsenic and Antimony Removal from Drinking Water by Point-of-Entry Reverse Osmosis Coupled with Dual Plumbing Distribution - U.S. EPA Demonstration Project at Carmel Elementary School in Carmel, ME -Final Performance Evaluation Report

    Science.gov (United States)

    This report documents the activities performed for and the results obtained from the arsenic and antimony removal treatment technology demonstration project at the Carmel Elementary School (CES) in Carmel, ME. An innovative approach of employing point of entry (POE) reverse osmo...

  20. Experimental study of dye removal from industrial wastewater by membrane technologies of reverse osmosis and nanofiltration

    Science.gov (United States)

    2012-01-01

    Currently, biological method has been utilized in the treatment of wastewater -containing synthetic dyes used by textile industries in Iraq. The present work was devoted to study the operating feasibility using reverse osmosis (RO) and nanofiltration (NF) membrane systems as an alternative treatment method of wastewater discharged from Iraqi textile mills. Acid red, reactive black and reactive blue dyes were selected, based on the usage rate in Iraq. Effects of dye concentration, pH of solution, feed temperature, dissolved salts and operating pressure on permeate flux and dye rejection were studied. Results at operating conditions of dye concentration = 65 mg/L, feed temperature = 39°C and pressure = 8 bar showed the final dye removal with RO membrane as 97.2%, 99.58% and 99.9% for acid red, reactive black and reactive blue dyes, respectively. With NF membrane, the final dye removal were as 93.77%, 95.67%, and 97% for red, black and blue dyes, respectively. The presence of salt (particularly NaCl) in the dye solution resulted in a higher color removal with a permeate flux decline. It was confirmed that pH of solution had a positive impact on dye removal while feed temperature showed a different image. A comparison was made between the results of dye removal in biological and membrane methods. The results showed that membrane method had higher removal potential with lower effective cost. The present study indicates that the use of NF membrane in dye removal from the effluent of Iraqi textile mills is promising. PMID:23369335

  1. Role of membrane fouling substances on the rejection of N-nitrosamines by reverse osmosis.

    Science.gov (United States)

    Fujioka, Takahiro; Kodamatani, Hitoshi; Aizawa, Hidenobu; Gray, Stephen; Ishida, Kenneth P; Nghiem, Long D

    2017-07-01

    The impact of fouling substances on the rejection of four N-nitrosamines by a reverse osmosis (RO) membrane was evaluated by characterizing individual organic fractions in a secondary wastewater effluent and deploying a novel high-performance liquid chromatography-photochemical reaction-chemiluminescence (HPLC-PR-CL) analytical technique. The HPLC-PR-CL analytical technique allowed for a systematic examination of the correlation between the fouling level and the permeation of N-nitrosamines in the secondary wastewater effluent and synthetic wastewaters through an RO membrane. Membrane fouling caused by the secondary wastewater effluent led to a notable decrease in the permeation of N-nitrosodimethylamine (NDMA) while a smaller but nevertheless discernible decrease in the permeation of N-nitrosomethylethylamine (NMEA), N-nitrosopyrrolidine (NPYR) and N-nitrosomorpholine (NMOR) was also observed. Fluorescence spectrometry analysis revealed that major foulants in the secondary wastewater effluent were humic and fulvic acid-like substances. Analysis using the size exclusion chromatography technique also identified polysaccharides and proteins as additional fouling substances. Thus, further examination was conducted using solutions containing model foulants (i.e., sodium alginate, bovine serum albumin, humic acid and two fulvic acids). Similar to the secondary wastewater effluent, membrane fouling with fulvic acid solutions resulted in a decrease in N-nitrosamine permeation. In contrast, membrane fouling with the other model foulants resulted in a negligible impact on N-nitrosamine permeation. Overall, these results suggest that the impact of fouling on the permeation of N-nitrosamines by RO is governed by specific small organic fractions (e.g. fulvic acid-like organics) in the secondary wastewater effluent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Effect of engineered environment on microbial community structure in biofilter and biofilm on reverse osmosis membrane.

    Science.gov (United States)

    Jeong, Sanghyun; Cho, Kyungjin; Jeong, Dawoon; Lee, Seockheon; Leiknes, TorOve; Vigneswaran, Saravanamuthu; Bae, Hyokwan

    2017-11-01

    Four dual media filters (DMFs) were operated in a biofiltration mode with different engineered environments (DMF I and II: coagulation with/without acidification and DMF III and IV: without/with chlorination). Designed biofilm enrichment reactors (BERs) containing the removable reverse osmosis (RO) coupons, were connected at the end of the DMFs in parallel to analyze the biofilm on the RO membrane by DMF effluents. Filtration performances were evaluated in terms of dissolved organic carbon (DOC) and assimilable organic carbon (AOC). Organic foulants on the RO membrane were also quantified and fractionized. The bacterial community structures in liquid (seawater and effluent) and biofilm (DMF and RO) samples were analyzed using 454-pyrosequencing. The DMF IV fed with the chlorinated seawater demonstrated the highest reductions of DOC including LMW-N as well as AOC among the other DMFs. The DMF IV was also effective in reducing organic foulants on the RO membrane surface. The bacterial community structure was grouped according to the sample phase (i.e., liquid and biofilm samples), sampling location (i.e., DMF and RO samples), and chlorination (chlorinated and non-chlorinated samples). In particular, the biofilm community in the DMF IV differed from the other DMF treatments, suggesting that chlorination exerted as stronger selective pressure than pH adjustment or coagulation on the biofilm community. In the DMF IV, several chemoorganotrophic chlorine-resistant biofilm-forming bacteria such as Hyphomonas, Erythrobacter, and Sphingomonas were predominant, and they may enhance organic carbon degradation efficiency. Diverse halophilic or halotolerant organic degraders were also found in other DMFs (i.e., DMF I, II, and III). Various kinds of dominant biofilm-forming bacteria were also investigated in RO membrane samples; the results provided possible candidates that cause biofouling when DMF process is applied as the pretreatment option for the RO process. Copyright

  3. Experimental study of dye removal from industrial wastewater by membrane technologies of reverse osmosis and nanofiltration

    Directory of Open Access Journals (Sweden)

    Abid Mohammad Fadhil

    2012-12-01

    Full Text Available Abstract Currently, biological method has been utilized in the treatment of wastewater -containing synthetic dyes used by textile industries in Iraq. The present work was devoted to study the operating feasibility using reverse osmosis (RO and nanofiltration (NF membrane systems as an alternative treatment method of wastewater discharged from Iraqi textile mills. Acid red, reactive black and reactive blue dyes were selected, based on the usage rate in Iraq. Effects of dye concentration, pH of solution, feed temperature, dissolved salts and operating pressure on permeate flux and dye rejection were studied. Results at operating conditions of dye concentration = 65 mg/L, feed temperature = 39°C and pressure = 8 bar showed the final dye removal with RO membrane as 97.2%, 99.58% and 99.9% for acid red, reactive black and reactive blue dyes, respectively. With NF membrane, the final dye removal were as 93.77%, 95.67%, and 97% for red, black and blue dyes, respectively. The presence of salt (particularly NaCl in the dye solution resulted in a higher color removal with a permeate flux decline. It was confirmed that pH of solution had a positive impact on dye removal while feed temperature showed a different image. A comparison was made between the results of dye removal in biological and membrane methods. The results showed that membrane method had higher removal potential with lower effective cost. The present study indicates that the use of NF membrane in dye removal from the effluent of Iraqi textile mills is promising.

  4. Spatial and temporal evolution of organic foulant layers on reverse osmosis membranes in wastewater reuse applications.

    Science.gov (United States)

    Farias, Elizabeth L; Howe, Kerry J; Thomson, Bruce M

    2014-07-01

    Advanced treatment to remove trace constituents and emerging contaminants is an important consideration for wastewater treatment for potable reuse, and reverse osmosis (RO) can be a suitable technology to provide the necessary level of treatment. However, membrane fouling by biological and organic matter is a concern. This research examined the development of the RO membrane fouling layer using a bench-scale membrane bioreactor operating at different solids retention times (SRTs), followed by a custom-designed RO test cell. The RO test cell contained stacked plates that sandwich five sheets of RO membrane material, which can be extracted for autopsy at separate times over the course of an experiment without disturbing the remaining membranes. The MBR-RO system was run continuously for 2 weeks at each SRT. The RO membranes were stained for live and dead cells, protein, and carbohydrate-like materials, and visualized using confocal laser scanning microscopy. Images of the stained foulant layers were obtained at different depths within the foulant layer at each time point for all SRT conditions. As the RO foulant layer developed, changes occurred in the distribution and morphology of the live cells and carbohydrates, but not the proteins. These trends were similar for all three SRT conditions tested. RO membrane fouling increased with increased MBR SRT, and the highest SRT had the highest ratios of live to dead cells and carbohydrate-like material to dead cells. The autopsied membranes were also analyzed for protein and carbohydrate content, and it was found that the carbohydrate concentration on the membranes after 14 days increased as the SRT increased. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Experimental Study of Dye Removal from Industrial Wastewater by Membrane Technologies of Reverse Osmosis and Nanofiltration

    Directory of Open Access Journals (Sweden)

    Mohammad Fadhil Abid

    2012-12-01

    Full Text Available Currently, biological method has been utilized in the treatment of wastewater -containing synthetic dyes used by textile industries in Iraq. The present work was devoted to study the operating feasibility using reverse osmosis (RO and nanofiltration (NF membrane systems as an alternative treatment method of wastewater discharged from Iraqi textile mills. Acid red, reactive black and reactive blue dyes were selected, based on the usage rate in Iraq. Effects of dye concentration, pH of solution, feed temperature, dissolved salts and operating pressure on permeate flux and dye rejection were studied. Results at operating conditions of dye concentration?=?65 mg/L, feed temperature?=?39?C and pressure?=?8 bar showed the final dye removal with RO membrane as 97.2%, 99.58% and 99.9% for acid red, reactive black and reactive blue dyes, respectively. With NF membrane, the final dye removal were as 93.77%, 95.67%, and 97% for red, black and blue dyes, respectively. The presence of salt (particularly NaCl in the dye solution resulted in a higher color removal with a permeate flux decline. It was confirmed that pH of solution had a positive impact on dye removal while feed temperature showed a different image. A comparison was made between the results of dye removal in biological and membrane methods. The results showed that membrane method had higher removal potential with lower effective cost. The present study indicates that the use of NF membrane in dye removal from the effluent of Iraqi textile mills is promising.

  6. Effect of engineered environment on microbial community structure in biofilter and biofilm on reverse osmosis membrane

    KAUST Repository

    Jeong, Sanghyun

    2017-07-25

    Four dual media filters (DMFs) were operated in a biofiltration mode with different engineered environments (DMF I and II: coagulation with/without acidification and DMF III and IV: without/with chlorination). Designed biofilm enrichment reactors (BERs) containing the removable reverse osmosis (RO) coupons, were connected at the end of the DMFs in parallel to analyze the biofilm on the RO membrane by DMF effluents. Filtration performances were evaluated in terms of dissolved organic carbon (DOC) and assimilable organic carbon (AOC). Organic foulants on the RO membrane were also quantified and fractionized. The bacterial community structures in liquid (seawater and effluent) and biofilm (DMF and RO) samples were analyzed using 454-pyrosequencing. The DMF IV fed with the chlorinated seawater demonstrated the highest reductions of DOC including LMW-N as well as AOC among the other DMFs. The DMF IV was also effective in reducing organic foulants on the RO membrane surface. The bacterial community structure was grouped according to the sample phase (i.e., liquid and biofilm samples), sampling location (i.e., DMF and RO samples), and chlorination (chlorinated and non-chlorinated samples). In particular, the biofilm community in the DMF IV differed from the other DMF treatments, suggesting that chlorination exerted as stronger selective pressure than pH adjustment or coagulation on the biofilm community. In the DMF IV, several chemoorganotrophic chlorine-resistant biofilm-forming bacteria such as Hyphomonas, Erythrobacter, and Sphingomonas were predominant, and they may enhance organic carbon degradation efficiency. Diverse halophilic or halotolerant organic degraders were also found in other DMFs (i.e., DMF I, II, and III). Various kinds of dominant biofilm-forming bacteria were also investigated in RO membrane samples; the results provided possible candidates that cause biofouling when DMF process is applied as the pretreatment option for the RO process.

  7. An integrated mechanical-enzymatic reverse osmosis treatment of dairy industry wastewater and milk protein recovery as a fat replacer: a closed loop approach

    Directory of Open Access Journals (Sweden)

    F. Sarghini

    2013-09-01

    Full Text Available The dairy industry can be classified among the most polluting of the food industries in volume in regard to its large water consumption, generating from 0.2 to 10 L of effluent per liter of processed milk. Dairy industry effluents usually include highly dissolved organic matter with varying characteristics, and a correct waste management project is required to handle. In a framework of natural water resource availability and cost increase, wastewater treatment for water reuse can lower the overall water consumption and the global effluent volume of industrial plants. Moreover, correct dismissal of dairy industry wastewater is sometimes neglected by the operators , increasing the environmental impact due to the chemical and biological characteristics of such effluents. On the other hand, in the case of whey effluents, several by-products are still present inside, such as lactose and milk proteins. Membrane technology has some advantages including a high degree of reliability in removing dissolved, colloidal and particulate matter, like the selectivity in size of pollutants to be removed and the possibility of very compact treatment plants. For example, Reverse Osmosis (RO technology has been successfully applied for the treatment of dairy wastes (1, and as a technology for concentration and fractionation of whey. In this work a membrane treatment approach using reverse osmosis technology is investigated and implemented: the permeate obtained can be reused as clean warm water for cleaning and sanitation of production plants, while concentrated milk proteins are modified by using transglutaminase enzyme obtaining a high temperature resistant fat replacer to be used in different low-fat products like for example mozzarella cheese.

  8. On the use of wind energy to power reverse osmosis desalination plant: A case study from Tenes (Algeria)

    Energy Technology Data Exchange (ETDEWEB)

    Dehmas, Djamila Abdeslame; Merzouk, Nachida Kasbadji [Wind Energy Division, Renewable Energy Development Center, BP. 62, Bouzareah, Algiers (Algeria); Kherba, Nabila; Hacene, Fouad Boukli [University Hassiba Ben Bouali of Chlef (Algeria); Merzouk, Mustapha [Mechanical Department, University Saad Dahlab of Blida (Algeria); Mahmoudi, Hacene [Wind Energy Division, Renewable Energy Development Center, BP. 62, Bouzareah, Algiers (Algeria); University Hassiba Ben Bouali of Chlef (Algeria); Goosen, Mattheus F.A. (Alfaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia)

    2011-02-15

    The aim of this study was to provide a detailed analysis of wind energy resources for seawater reverse osmosis desalination (SWRO), in a case study region of Tenes Algeria, by using commercial Wasp software. An economic analysis of the environmental benefits was also done using RETScreen software to give details about financial investment hazards and CO{sub 2} emissions reduction. An energy yield and economical analysis was performed of a hypothetical wind farm consisting of 5 wind turbines of type Bonus 2 MW. It was found that wind energy can successfully power a SWRO desalination plant in the case study region. (author)

  9. Biofouling of reverse-osmosis membranes under different shear rates during tertiary wastewater desalination: microbial community composition.

    Science.gov (United States)

    Al Ashhab, Ashraf; Gillor, Osnat; Herzberg, Moshe

    2014-12-15

    We investigated the influence of feed-water shear rate during reverse-osmosis (RO) desalination on biofouling with respect to microbial community composition developed on the membrane surface. The RO membrane biofilm's microbial community profile was elucidated during desalination of tertiary wastewater effluent in a flat-sheet lab-scale system operated under high (555.6 s(-1)), medium (370.4 s(-1)), or low (185.2 s(-1)) shear rates, corresponding to average velocities of 27.8, 18.5, and 9.3 cm s(-1), respectively. Bacterial diversity was highest when medium shear was applied (Shannon-Weaver diversity index H' = 4.30 ± 0.04) compared to RO-membrane biofilm developed under lower and higher shear rates (H' = 3.80 ± 0.26 and H' = 3.42 ± 0.38, respectively). At the medium shear rate, RO-membrane biofilms were dominated by Betaproteobacteria, whereas under lower and higher shear rates, the biofilms were dominated by Alpha- and Gamma- Proteobacteria, and the latter biofilms also contained Deltaproteobacteria. Bacterial abundance on the RO membrane was higher at low and medium shear rates compared to the high shear rate: 8.97 × 10(8) ± 1.03 × 10(3), 4.70 × 10(8) ± 1.70 × 10(3) and 5.72 × 10(6) ± 2.09 × 10(3) copy number per cm(2), respectively. Interestingly, at the high shear rate, the RO-membrane biofilm's bacterial community consisted mainly of populations known to excrete high amounts of extracellular polymeric substances. Our results suggest that the RO-membrane biofilm's community composition, structure and abundance differ in accordance with applied shear rate. These results shed new light on the biofouling phenomenon and are important for further development of antibiofouling strategies for RO membranes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. ANALISIS PERMEASI AIR PADA DEHIDRASI OSMOSIS PEPAYA (Carica papaya Water Permeation Analysis on Osmotic Dehydration of Papaya (Carica papaya

    Directory of Open Access Journals (Sweden)

    Sang Kompiang Wirawan

    2013-11-01

    Full Text Available Fruit preservation using low temperature drying is commonly initiated by osmotic dehydration process. The osmotic time is strongly influenced by the water permeation from the fruit to the osmotic solution. This research aimed to study the osmotic dehydration process of papaya by finding out the permeation rate of water to the osmotic solution across a semi permeable membrane. The effect of temperature and osmotic solution concentration on the permeation rate were also observed. The osmotic temperatures were 30, 40, 50, and 60oC, and the osmotic solution concentration were 55, 60, 65, and 70%. In order to study the water permeation through the semi permeable membrane, a simple mass transfer mathematical models based on Fick’s and Van’t Hoff laws were applied. Generally, higher temperature and osmotic solution concentration, higher water permeation rate was achieved. The results also showed that osmotic dehydration has the same identity or characteristic as drying process at high temperature. The water removal from product slices into the osmotic solution increased by the increase of osmotic period. The mass transfer coefficient and effective diffusivity of water increased when temperature and osmotic solution concentration were increased. However, the membrane permeability has a special characteristic at the ranges conditions studied. Keywords: Osmotic, permeation, dehydration, permeable, membrane ABSTRAK Pengawetan buah dengan pengeringan suhu rendah pada umumnya diawali dengan proses dehidrasi osmosis. Lama waktu osmosis sangat dipengaruhi oleh permeasi air dari bahan ke larutan osmosis. Penelitian ini bertujuan untuk mempelajari proses dehidrasi osmosis dan kecepatan permeasi air dari pepaya ke larutan gula sebagai larutan osmosis melalui membran semipermeabel. Pengaruh suhu dan konsentrasi larutan osmosis terhadap kecepatan permeasi air juga diamati. Suhu osmosis adalah 30, 40, 50, dan 60oC, sedangkan konsentrasi larutan osmosis 55, 60

  11. A feasibility study of ultrafiltration/reverse osmosis (UF/RO)-based wastewater treatment and reuse in the metal finishing industry

    DEFF Research Database (Denmark)

    Petrinic, Irena; Korenak, Jasmina; Povodnik, Damijan

    2015-01-01

    studied the technical and economic feasibilities of adding an ultrafiltration process as a pre-treatment for removing dissolved and colloidal contaminants >0.4μm, and to eliminate membrane fouling before a final reverse osmosis process resulting in permeate that would meet reuse criteria. The results show...... that the ultrafiltration-reverse osmosis treatment removed between 91.3% and 99.8% of the contaminants from the effluent, such as metal elements, organic, and inorganic compounds. Contaminants such as suspended solids, nickel, ammonium nitrogen, sulphate nitrogen, chemical oxygen demand, and biochemical oxygen demand were...... completely removed, the concentrations in the permeate being under the detection limits, thus the quality of the ultrafiltration-reverse osmosis process met the reuse criteria. This demonstrates the technological feasibility of wastewater reuse during electro-plating processes and the pre-treatment of powder...

  12. Feed substrates influence biofilm formation on reverse osmosis membranes and their cleaning efficiency.

    Science.gov (United States)

    Marka, Sowmya; Anand, Sanjeev

    2018-01-01

    The dairy industry is increasingly using reverse osmosis (RO) membranes for concentration of various fluid feed materials such as whey and ultrafiltration (UF) permeate. This study compared the effect of UF permeate and whey on membrane biofilm formation. A Bacillus sp., previously isolated in our laboratory from a cleaning-resistant membrane biofilm, was used to develop 48-h-old static biofilms on RO membrane pieces, using the different feed substrates (UF permeate, whey, and an alternating whey/UF feed). Biofilms were analyzed for viable counts by the swab technique, and we used scanning electron and atomic force microscopy for microstructure imaging. The membrane cleaning process included 6 sequential steps. We observed differences in the resistance pattern of the 3 types of biofilms to the typical cleaning process. The mean pretreatment counts of the 48-h UF permeate biofilms were 5.39 log cfu/cm2, much higher than the whey biofilm counts of 3.44 log, and alternating whey/UF biofilm counts of 4.54 log. After a 6-step cleaning cycle, we found 2.54 log survivors of the Bacillus isolate on UF biofilms, whereas only 1.82 log survivors were found in whey biofilm, and 2.14 log survivors on whey/UF permeate biofilms. In conclusion, the UF permeate biofilms was more resistant to the biofilm cleaning process compared with the whey or whey/UF permeate biofilms. Scanning electron micrographs showed different microstructures of biofilms based on the type of feed. For UF permeate and whey/UF permeate biofilms, bacilli were present in multilayers of cells in aggregates or irregular clusters with foulant layers. In contrast, those in whey biofilms were in monolayers, with a smoother, flatter appearance. Atomic force microscopy analysis indicated that UF permeate biofilms had the greatest surface roughness among the biofilms, reflecting intensified bacterial colonization. The biofilm micro- and nanostructure variations for the 2 feed substrates and their combination may have

  13. Surface modification of commercial seawater reverse osmosis membranes by grafting of hydrophilic monomer blended with carboxylated multiwalled carbon nanotubes

    Science.gov (United States)

    Vatanpour, Vahid; Zoqi, Naser

    2017-02-01

    In this study, modification of commercial seawater reverse osmosis membranes was carried out with simultaneous use of surface grafting and nanoparticle incorporation. Membrane grafting with a hydrophilic acrylic acid monomer and thermal initiator was used to increase membrane surface hydrophilicity. The used nanomaterial was carboxylated multiwalled carbon nanotubes (MWCNTs), which were dispersed in the grafting solution and deposited on membrane surface to reduce fouling by creating polymer brushes and hydrodynamic resistance. Effectiveness of the grafting process (formation of graft layer on membrane surface) was proved by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) analyses. Increase of membrane surface hydrophilicity was approved with contact angle test. First, the grafting was performed on the membrane surfaces with different monomer concentrations, various contact times and several membrane curing times (three variables for optimization). The modified membranes were tested by a cross-flow setup using saline solution for permeability and rejection tests, and bovine serum albumin (BSA) solution for fouling test. The results showed that the modified membranes with 0.75 M of monomer, 3 min contact time and 80 min curing time in an oven at 50 °C presented the highest flux and lowest rejection decline related to the commercial reverse osmosis membrane. In the next step, the optimum grafting condition was selected and the nanotubes with different weight percentages were dispersed in the acrylic acid monomer solution. The membrane containing 0.25 wt% COOH-MWCNTs showed the highest fouling resistance.

  14. Changes in the components and biotoxicity of dissolved organic matter in a municipal wastewater reclamation reverse osmosis system.

    Science.gov (United States)

    Sun, Ying-Xue; Hu, Hong-Ying; Shi, Chun-Zhen; Yang, Zhe; Tang, Fang

    2016-09-01

    The characteristics of dissolved organic matter (DOM) and the biotoxicity of these components were investigated in a municipal wastewater reclamation reverse osmosis (mWRRO) system with a microfiltration (MF) pretreatment unit. The MF pretreatment step had little effect on the levels of dissolved organic carbon (DOC) in the secondary effluent, but the addition of chlorine before MF promoted the formation of organics with anti-estrogenic activity. The distribution of excitation emission matrix (EEM) fluorescence constituents exhibited obvious discrepancies between the secondary effluent and the reverse osmosis (RO) concentrate. Using size exclusion chromatography, DOM with low molecular weights of approximately 1.2 and 0.98 kDa was newly formed during the mWRRO. The normalized genotoxicity and anti-estrogenic activity of the RO concentrate were 32.1 ± 10.2 μg4-NQO/mgDOC and 0.36 ± 0.08 mgTAM/mgDOC, respectively, and these values were clearly higher than those of the secondary effluent and MF permeate. The florescence volume of Regions I and II in the EEM spectrum could be suggested as a surrogate for assessing the genotoxicity and anti-estrogenic activity of the RO concentrate.

  15. Performance of Potassium Bicarbonate and Calcium Chloride Draw Solutions for Desalination of Saline Water Using Forward Osmosis

    Directory of Open Access Journals (Sweden)

    M. Nematzadeh

    2015-01-01

    Full Text Available Forward osmosis (FO has recently drawn attention as a promising membrane based method for seawater and brackish water desalination. In this study, we focus on the use of calciun chloride (CaCl2 and potassium bicarbonate (KHCO3 as inorganic salt draw solution candidates due to their appropriate performance in water flux and reverse salt diffusion as well as reasonable cost. The experiments were carried at 25 °C and cross-flow rate of 3 L min−1.  At the same osmotic pressure, the water flux of CaCl2 draw solution tested against deionized feed water, showed 20% higher permeation than KHCO3, which it was attributed to the lower internal concentration polarization (ICP. The reverse diffusion of CaCl2 was found higher than KHCO3 solution which it would be related to the smaller ionic size and the higher permeation of this salt through the membrane. The water flux for both draw solutions against 0.33 M NaCl feed solution was about 2.8 times lower than deionized feed water because of ICP. Higher concentrations of draw solution is required for increasing the water permeation from saline water feed towards the draw side.

  16. Selection of inorganic-based fertilizers in forward osmosis for water desalination

    Directory of Open Access Journals (Sweden)

    Tripti Mishra

    2015-06-01

    Full Text Available The current study aims at the selection of an appropriate draw solute for forward osmosis process. Separation and recovery of the draw solute are the major criteria for the selection of draw solute for forward osmosis process. Therefore in this investigation six inorganic fertilizers draws solute were selected. The selections of inorganic fertilizers as draw solute eliminate the need of removal and recovery of draw solute from the final product. The final product water of forward osmosis process has direct application in agricultural as nutrient rich water for irrigation. These inorganic fertilizers were tested based on their water extraction (water flux capacity. This experimental water flux was compared with the observed water flux. It was noted that the observed water flux is much higher than the attained experimental water flux. The difference of these two fluxes was used to calculate the performance ratio of each selected fertilizer. Highest performance ratio was shown by low molecular weight compound ammonium nitrate (22.73 and potassium chloride (21.03 at 1 M concentration, whereas diammonium phosphate (DAP which has highest molecular weight among all the selected fertilizer show the lowest performance ratio (10.02 at 2 M concentration. DOI: http://dx.doi.org/10.3126/ije.v4i2.12660 International Journal of Environment Vol.4(2 2015: 319-329

  17. Feasibility of Gallery Intake Systems for Seawater Reverse Osmosis Facilities along the Northern Red Sea Coast of Saudi Arabia

    KAUST Repository

    Dehwah, Abdullah

    2012-03-01

    The Kingdom of Saudi Arabia is dependent on desalination of seawater to provide new water supplies for the future. Desalination is expensive and it is very important to reduce the cost and lower the energy consumption. Most seawater reverse osmosis facilities use open-ocean intakes, which require extensive pre-treatment processes to remove particulate and biological materials that cause operating problems. An alternative intake is the subsurface system which utilizes the concept of riverbank filtration using wells or galleries and provides natural filtration to improve the quality of feedwater before it enters the desalination plant. This reduces operating cost and lowers energy consumption. Research was focused on evaluating gallery-type intakes (beach and seabed galleries) that could be used along the Northern Red Sea shoreline to provide a better quality feedwater for desalination. The geological characteristics of the visited sites were favorable for the development of seabed filter systems (offshore), but not for beach gallery intakes. The low wave energy along the shoreline and the presence of mud or rocky coasts made beach galleries infeasible. One of the potentially favorable sites for a seabed filter was located in the nearshore area at King Abdullah Economic City (KAEC). This site has a predominantly sandy offshore bottom with shallow water depths, and a low tide range. In addition, the bottom is always covered with water and contains soft limestone unit below the sand mantle that could be easy excavated to facilitate the construction of a seabed filter. About 50 sediment samples were collected from the site and laboratory measurements were performed on them. Grain size distribution, porosity and hydraulic conductivity measurements were performed on the sediment samples. In addition, six statistical methods were used to estimate the hydraulic conductivity values. Based on results of lab measurements, field observations, tide ranges and sediment types, it

  18. Highly water soluble nanoparticles as a draw solute in forward osmosis for the treatment of radioactive liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Heeman; Choi, Hye Min; Jang, Sungchan; Seo, Bumkyoung; Lee, Kune Woo; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    . In this study, we introduced highly water-soluble hyperbranched caroboxylated polyglycerol-coated magnetic nanoparticles (CPG-MNPs). It is known that the highly branched, globular architecture of PG significantly increase solubility compared to linear polymer and they are eco-friendly. The CPG-MNPs showed no aggregate of particles in water even after placing external magnet, and exhibited a high water flux in FO process. The CPG-MNPs are, therefore, potentially useful as a draw solute in FO processes. The operation of nuclear pressurized water reactors (PWRs) results in numerous radioactive waste streams which vary in radioactivity content. Most PWR stations have experienced leakages of boric acid into liquid radioactive waste systems. These wastes contain about 0.3∼0.8 wt% of boric acid. It is known that reverse osmosis (RO) membrane can eliminate boron at high pH and boron of 40∼90% can be removed by RO membrane in pH condition. RO uses hydraulic pressure to oppose, and exceed, the osmotic pressure of an aqueous feed solution containing boric acid. Forward osmosis (FO), a low energy technique based on membrane technologies, has recently garnered attention for its utility in wastewater treatment and desalination applications. In the FO process, water flows across a semi-permeable membrane from a solution with a low osmotic pressure (the feed solution) to a solution with a high osmotic pressure (the draw solution). The driving force in FO processes is provided by the osmotic gradient between the two solutions. Low energy costs and low degrees of membrane fouling are two of the advantages conveyed by FO processes over other processes, such as reverse osmosis processes that rely on a hydraulic pressure driving force. However, the challenges of FO still lie in the fabrication of eligible FO membranes and the readily separable draw solutes of high osmotic pressures. Superparamagnetic Fe3O4 nanoparticles can be separated from water by an external magnet field

  19. Water purification by reverse osmosis using heterocyclic polymer membranes

    Science.gov (United States)

    Scott, H.

    1972-01-01

    Pyrrone (polyimidazopyrrolone) polymers are a new class of thermally stable, radiation and chemical resistant aromatic-heterocyclic polymers featuring a greater chemical and mechanical durability than cellulose acetate.

  20. A comparison of the performance of aromatic polyamide and cellulose acetate reverse osmosis membrane on the regeneration of secondary effluents; Comparacion del funcionamiento de membranas de osmosis inversa de poliamida aromatica y acetato de celulosa en la regeneracion de efluentes secundarios

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Ramirez, J. A.; Carrasco Vega, M.; Sales Marquez, D.; Quiroga Alonso, J. M.

    2002-07-01

    The application of reverse osmosis in regenerating waste waters has aroused a great deal of interest, although relatively few experiments using this technique have so far been carried out in Spain. In 1994, an experimental pilot plant was built at the La Barrosa waste water treatment plant in Chiclana de la Frontera in the province of Cadiz. This pilot plant with a capacity of 100 m''3/day, was equipped with various advanced treatments, most notably reverse osmosis, for treating urban waste waters for re-use. Since this pilot plant was built, various experiments have been carried out employing cellulose acetate (Hydranautics) and different types of Spanish-made aromatic polyamide membranes (Pridesa). Each type of membrane proposed different operating characteristics and feed-water requirements making each one suitable for a particular purpose. In this study, the secondary effluents was subjected to different kinds of treatment-called intense treatment, moderate treatment and minimum treatment-before reaching the reverse osmosis unit, which influenced the conditions in which the membranes operated. Following each type of treatment, the waters entering and leaving the installation were analysed to evaluate the quality of the final effluent and the effectiveness of the treatment carried out. The quality was extremely good in all the permeate samples analysed, almost irrespective of the type of treatment applied. It was also found that the cellulose acetate membranes tended to become less dirty than the aromatic polyamide membranes,due to their surface morphology. Nevertheless, the polyamide membranes have various advantages allowing them to be used in a wide range of applications at a lower energy cost. (Author) 8 refs.

  1. Fertilizer drawn forward osmosis process for sustainable water reuse to grow hydroponic lettuce using commercial nutrient solution

    KAUST Repository

    Chekli, Laura

    2017-03-10

    This study investigated the sustainable reuse of wastewater using fertilizer drawn forward osmosis (FDFO) process through osmotic dilution of commercial nutrient solution for hydroponics, a widely used technique for growing plants without soil. Results from the bench-scale experiments showed that the commercial hydroponic nutrient solution (i.e. solution containing water and essential nutrients) exhibited similar performance (i.e., water flux and reverse salt flux) to other inorganic draw solutions when treating synthetic wastewater. The use of hydroponic solution is highly advantageous since it provides all the required macro- (i.e., N, P and K) and micronutrients (i.e., Ca, Mg, S, Mn, B, Zn and Mo) in a single balanced solution and can therefore be used directly after dilution without the need to add any elements. After long-term operation (i.e. up to 75% water recovery), different physical cleaning methods were tested and results showed that hydraulic flushing can effectively restore up to 75% of the initial water flux while osmotic backwashing was able to restore the initial water flux by more than 95%; illustrating the low-fouling potential of the FDFO process. Pilot-scale studies demonstrated that the FDFO process is able to produce the required nutrient concentration and final water quality (i.e., pH and conductivity) suitable for hydroponic applications. Coupling FDFO with pressure assisted osmosis (PAO) in the later stages could help in saving operational costs (i.e., energy and membrane replacement costs). Finally, the test application of nutrient solution produced by the pilot FDFO process to hydroponic lettuce showed similar growth pattern as the control without any signs of nutrient deficiency.

  2. Advantages and application of forward osmosis

    Science.gov (United States)

    This month's Processing column explores the use of forward osmosis to dewater and concentrate. Forward osmosis is performed with specially designed membranes and requires very little energy. Where thermal evaporation and reverse osmosis may damage or alter products, forward osmosis preserves the s...

  3. Biofouling of reverse osmosis membranes: effects of cleaning on biofilm microbial communities, membrane performance, and adherence of extracellular polymeric substances.

    Science.gov (United States)

    Al Ashhab, Ashraf; Sweity, Amer; Bayramoglu, Bihter; Herzberg, Moshe; Gillor, Osnat

    2017-05-01

    Laboratory-scale reverse osmosis (RO) flat-sheet systems were used with two parallel flow cells, one treated with cleaning agents and a control (ie undisturbed). The cleaning efforts increased the affinity of extracellular polymeric substances (EPS) to the RO membrane and altered the biofilm surface structure. Analysis of the membrane biofilm community composition revealed the dominance of Proteobacteria. However, within the phylum Proteobacteria, γ-Proteobacteria dominated the cleaned membrane biofilm, while β-Proteobacteria dominated the control biofilm. The composition of the fungal phyla was also altered by cleaning, with enhancement of Ascomycota and suppression of Basidiomycota. The results suggest that repeated cleaning cycles select for microbial groups that strongly attach to the RO membrane surface by producing rigid and adhesive EPS that hampers membrane performance.

  4. A new flat sheet membrane bioreactor hybrid system for advanced treatment of effluent, reverse osmosis pretreatment and fouling mitigation.

    Science.gov (United States)

    Hosseinzadeh, Majid; Bidhendi, Gholamreza Nabi; Torabian, Ali; Mehrdadi, Naser; Pourabdullah, Mehdi

    2015-09-01

    This paper introduces a new hybrid electro membrane bioreactor (HEMBR) for reverse osmosis (RO) pretreatment and advanced treatment of effluent by simultaneously integrating electrical coagulation (EC) with a membrane bioreactor (MBR) and its performance was compared with conventional MBR. Experimental results and their statistical analysis showed removal efficiency for suspended solids (SS) of almost 100% for both reactors. HEMBR removal of chemical oxygen demand (COD) improved by 4% and membrane fouling was alleviated according to transmembrane pressure (TMP). The average silt density index (SDI) of HEMBR permeate samples was slightly better indicating less RO membrane fouling. Moreover, based on the SVI comparison of two reactor biomass samples, HEMBR showed better settling characteristics which improved the dewaterability and filterability of the sludge. Analysis the change of membrane surfaces and the cake layer formed over them through field emission scanning electron microscopy (FESEM) and X-ray fluorescence spectrometer (XRF) were also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Model-based performance and energy analyses of reverse osmosis to reuse wastewater in a PVC production site.

    Science.gov (United States)

    Hu, Kang; Fiedler, Thorsten; Blanco, Laura; Geissen, Sven-Uwe; Zander, Simon; Prieto, David; Blanco, Angeles; Negro, Carlos; Swinnen, Nathalie

    2017-11-10

    A pilot-scale reverse osmosis (RO) followed behind a membrane bioreactor (MBR) was developed for the desalination to reuse wastewater in a PVC production site. The solution-diffusion-film model (SDFM) based on the solution-diffusion model (SDM) and the film theory was proposed to describe rejections of electrolyte mixtures in the MBR effluent which consists of dominant ions (Na+ and Cl-) and several trace ions (Ca2+, Mg2+, K+ and SO42-). The universal global optimisation method was used to estimate the ion permeability coefficients (B) and mass transfer coefficients (K) in SDFM. Then, the membrane performance was evaluated based on the estimated parameters which demonstrated that the theoretical simulations were in line with the experimental results for the dominant ions. Moreover, an energy analysis model with the consideration of limitation imposed by the thermodynamic restriction was proposed to analyse the specific energy consumption of the pilot-scale RO system in various scenarios.

  6. Characterization and biotoxicity assessment of dissolved organic matter in RO concentrate from a municipal wastewater reclamation reverse osmosis system.

    Science.gov (United States)

    Sun, Ying-Xue; Gao, Yue; Hu, Hong-Ying; Tang, Fang; Yang, Zhe

    2014-12-01

    Reverse osmosis (RO) concentrate from municipal wastewater reclamation reverse osmosis (mWRRO) system containing organic compounds may associate with toxic risk, and its discharge might pose an environmental risk. To identify a basis for the selection of feasible technology in treating RO concentrates, the characteristics and biotoxicity of different fractions of dissolved organic matter (DOM) in RO concentrates from an mWRRO system were investigated. The results indicated that the hydrophilic neutrals (HIN), hydrophobic acids (HOA) and hydrophobic bases (HOB) accounted for 96% of the dissolved organic carbon (DOC) of the total DOM in the RO concentrate. According to the SEC chromatograph detected at 254 nm wavelength of UV, the DOM with molecular weight (MW) 1-3 kDa accounted for the majority of the basic and neutral fractions. The fluorescence spectra of the excitation emission matrix (EEM) indicated that most aromatic proteins, humic/fulvic acid-like and soluble microbial by-product-like substances existed in the fractions HOA and hydrophobic neutrals (HON). The genotoxicity and anti-estrogenic activity of the RO concentrate were 1795.6 ± 57.2 μg 4-NQOL(-1) and 2.19 ± 0.05 mg TAM L(-1), respectively. The HIN, HOA, and HOB contributed to the genotoxicity of the RO concentrate, and the HIN was with the highest genotoxic level of 1007.9 ± 94.8 μg 4-NQOL(-1). The HOA, HON, and HIN lead to the total anti-estrogenic activity of the RO concentrate, and HOA occupied approximately 60% of the total, which was 1.3 ± 0.17 mg TAM L(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Surface modification of commercial seawater reverse osmosis membranes by grafting of hydrophilic monomer blended with carboxylated multiwalled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Vatanpour, Vahid, E-mail: vahidvatanpour@khu.ac.ir; Zoqi, Naser

    2017-02-28

    Highlights: • A commercial PA RO membrane was modified by grafting of hydrophilic acrylic acid. • COOH-MWCNTs were mixed in grafting layer to increase permeability and antifouling. • However, more increase of CNTs caused in reduction of flux of the membranes. • Effect of acrylic acid amount, contact time and curing time was optimized. - Abstract: In this study, modification of commercial seawater reverse osmosis membranes was carried out with simultaneous use of surface grafting and nanoparticle incorporation. Membrane grafting with a hydrophilic acrylic acid monomer and thermal initiator was used to increase membrane surface hydrophilicity. The used nanomaterial was carboxylated multiwalled carbon nanotubes (MWCNTs), which were dispersed in the grafting solution and deposited on membrane surface to reduce fouling by creating polymer brushes and hydrodynamic resistance. Effectiveness of the grafting process (formation of graft layer on membrane surface) was proved by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) analyses. Increase of membrane surface hydrophilicity was approved with contact angle test. First, the grafting was performed on the membrane surfaces with different monomer concentrations, various contact times and several membrane curing times (three variables for optimization). The modified membranes were tested by a cross-flow setup using saline solution for permeability and rejection tests, and bovine serum albumin (BSA) solution for fouling test. The results showed that the modified membranes with 0.75 M of monomer, 3 min contact time and 80 min curing time in an oven at 50 °C presented the highest flux and lowest rejection decline related to the commercial reverse osmosis membrane. In the next step, the optimum grafting condition was selected and the nanotubes with different weight percentages were dispersed in the acrylic acid monomer solution. The membrane containing 0.25 wt% COOH-MWCNTs showed the

  8. Evaluation of the treatment of reverse osmosis concentrates from municipal wastewater reclamation by coagulation and granular activated carbon adsorption.

    Science.gov (United States)

    Sun, Ying-Xue; Yang, Zhe; Ye, Tao; Shi, Na; Tian, Yuan

    2016-07-01

    Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW <5 kDa. However, the post-GAC adsorption column (with filtration velocity of 5.7 m/h, breakthrough point adsorption capacity of 0.22 mg DOC/g GAC) exhibited excellent removal efficiency on the dominant DOM fraction of MW <5 kDa in the ROC. The removal efficiency of DOC, UV254, and TDS in the ROC was up to 91.8, 96, and 76.5 %, respectively, by the FeCl3 coagulation and post-GAC adsorption. Also, the DOM with both genotoxicity and antiestrogenic activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.

  9. The role of a combined coagulation and disk filtration process as a pre-treatment to microfiltration and reverse osmosis membranes in a municipal wastewater pilot plant.

    Science.gov (United States)

    Chon, Kangmin; Cho, Jaeweon; Kim, Seung Joon; Jang, Am

    2014-12-01

    A pilot study was conducted to assess the performance of a municipal wastewater reclamation plant consisting of a combined coagulation-disk filtration (CC-DF) process, microfiltration (MF) and reverse osmosis (RO) membranes, in terms of the removal of water contaminants and changes in characteristics of effluent organic matter (EfOM). The CC-DF and MF membranes were not effective for the removal of dissolved water contaminants. However, they could partially reduce the turbidity associated with the cake layer formation by particulate materials on the membrane surfaces. Furthermore, most of water contaminants were completely removed by the RO membranes. Although the CC-DF process could remove approximately 20% of turbidity, the aluminium concentrations considerably increased after the CC-DF process due to the residual coagulants complexed with both carboxylic acid and alcohol functional groups of EfOM. Those aluminium-EfOM complexes had a lower negative charge and higher molecular weight (>0.1 μm pore size of the MF membranes) compared to non-complexed EfOM. These results indicate that the control of the formation of the aluminium-EfOM complexes should be considered as a key step to use the CC-DF process as a pre-treatment of the MF and RO membranes for mitigation of membrane fouling in the tested pilot plant. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Methane production in an anaerobic osmotic membrane bioreactor using forward osmosis: Effect of reverse salt flux

    KAUST Repository

    Li, Sheng

    2017-05-10

    This study investigated the impact of reverse salt flux (RSF) on microbe community and bio-methane production in a simulated fertilizer driven FO-AnMBR system using KCl, KNO3 and KH2PO4 as draw solutes. Results showed that KH2PO4 exhibited the lowest RSF in terms of molar concentration 19.1 mM/(m2.h), while for KCl and KNO3 it was 32.2 and 120.8 mM/(m2.h), respectively. Interestingly, bio-methane production displayed an opposite order with KH2PO4, followed by KCl and KNO3. Pyrosequencing results revealed the presence of different bacterial communities among the tested fertilizers. Bacterial community of sludge exposed to KH2PO4 was very similar to that of DI-water and KCl. However, results with KNO3 were different since the denitrifying bacteria were found to have a higher percentage than the sludge with other fertilizers. This study demonstrated that RSF has a negative effect on bio-methane production, probably by influencing the sludge bacterial community via environment modification.

  11. Methane production in an anaerobic osmotic membrane bioreactor using forward osmosis: Effect of reverse salt flux.

    Science.gov (United States)

    Li, Sheng; Kim, Youngjin; Phuntsho, Sherub; Chekli, Laura; Shon, Ho Kyong; Leiknes, TorOve; Ghaffour, Noreddine

    2017-09-01

    This study investigated the impact of reverse salt flux (RSF) on microbe community and bio-methane production in a simulated fertilizer driven FO-AnMBR system using KCl, KNO3 and KH2PO4 as draw solutes. Results showed that KH2PO4 exhibited the lowest RSF in terms of molar concentration 19.1mM/(m2.h), while for KCl and KNO3 it was 32.2 and 120.8mM/(m2.h), respectively. Interestingly, bio-methane production displayed an opposite order with KH2PO4, followed by KCl and KNO3. Pyrosequencing results revealed the presence of different bacterial communities among the tested fertilizers. Bacterial community of sludge exposed to KH2PO4 was very similar to that of DI-water and KCl. However, results with KNO3 were different since the denitrifying bacteria were found to have a higher percentage than the sludge with other fertilizers. This study demonstrated that RSF has a negative effect on bio-methane production, probably by influencing the sludge bacterial community via environment modification. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Highly Water-Soluble Magnetic Nanoparticles as Novel Draw Solutes in Forward Osmosis for Water Reuse

    KAUST Repository

    Ling, Ming Ming

    2010-06-16

    Highly hydrophilic magnetic nanoparticles have been molecularly designed. For the first time, the application of highly water-soluble magnetic nanoparticles as novel draw solutes in forward osmosis (FO) was systematically investigated. Magnetic nanoparticles functionalized by various groups were synthesized to explore the correlation between the surface chemistry of magnetic nanoparticles and the achieved osmolality. We verified that magnetic nanoparticles capped with polyacrylic acid can yield the highest driving force and subsequently highest water flux among others. The used magnetic nanoparticles can be captured by the magnetic field and recycled back into the stream as draw solutes in the FO process. In addition, magnetic nanoparticles of different diameters were also synthesized to study the effect of particles size on FO performance. We demonstrate that the engineering of surface hydrophilicity and magnetic nanoparticle size is crucial in the application of nanoparticles as draw solutes in FO. It is believed that magnetic nanoparticles will soon be extensively used in this area. © 2010 American Chemical Society.

  13. Influence of bulk concentration on the organisation of molecules at a membrane surface and flux decline during reverse osmosis of an anionic surfactant

    OpenAIRE

    Mai, Zhaohuan; Butin, Vincent; Rakib, Mohammed; Zhu, Haochen; Rabiller-Baudry, Murielle; Couallier, Estelle

    2016-01-01

    International audience; Surfactants are extensively used in household and industrial products. Several processes exist to treat industrial wastewaters, including membrane filtration such as ultrafiltration, nanofiltration and reverse osmosis (RO). We studied fouling of RO membranes during filtration of aqueous anionic surfactant solutions under different conditions. The aim was to describe the local organisation of the surfactant at the membrane interface. To this end, the typical surfactant ...

  14. Synthesis and Characterization of Hydrophobic-Hydrophilic  Multiblock Copolymers for Proton Exchange Membrane and Segmented Copolymer Precursors for Reverse Osmosis Applications

    OpenAIRE

    Mehta, Ishan

    2014-01-01

    High performance engineering materials, poly(arylene ether)s, having very good mechanical properties, excellent oxidative and hydrolytic stability are promising candidates for alternative materials used in the field of Proton Exchange Membrane Fuel Cells (PEMFCs) and Reverse Osmosis (RO) applications. In particular, wholly aromatic sulfonated poly(arylene ether sulfone)s are of considerable interest in the field of PEMFCs and RO, due to their affordability, high Tg, and the ease of sulfonatio...

  15. Characterization and Evaluation of the Improved Performance of Modified Reverse Osmosis Membranes by Incorporation of Various Organic Modifiers and SnO2 Nanoparticles

    Directory of Open Access Journals (Sweden)

    Kh. M. AL-Sheetan

    2015-01-01

    Full Text Available Reverse osmosis (RO membranes modified with SnO2 nanoparticles of varied concentrations (0.001–0.1 wt.% were developed via in situ interfacial polymerization (IP of trimesoyl chloride (TMC and m-phenylenediamine (MPD on nanoporous polysulfone supports. The nanoparticles dispersed in the dense nodular polyamide on the polysulfone side. The effects of IP reaction time and SnO2 loading on membrane separation performance were studied. The modified reverse osmosis membranes were characterized by scanning electron microscopy (SEM, X-ray diffractometer (XRD, energy dispersive X-ray spectroscopy (EDX, transmission electron microscopy (TEM, contact angle measurement, and atomic force microscopy (AFM. The synthesized SnO2 nanoparticles size varies between 10 and 30 nm. The results exhibited a smooth membrane surface and average surface roughness from 31 to 68 nm. Moreover, hydrophilicity was enhanced and contact angle decreased. The outcomes showed that an IP reaction time was essential to form a denser SnO2-polyamide layer for higher salt rejection, the developed reverse osmosis membranes with the incorporation of the SnO2 nanoparticles were examined by measuring permeate fluxes and salt rejection, and the permeate flux increased from 26 to 43.4 L/m2·h, while salt rejection was high at 98% (2000 ppm NaCl solution at 225 psi (1.55 MPa, 25°C.

  16. Recovering/concentrating of hemicellulosic sugars and acetic acid by nanofiltration and reverse osmosis from prehydrolysis liquor of kraft based hardwood dissolving pulp process.

    Science.gov (United States)

    Ahsan, Laboni; Jahan, M Sarwar; Ni, Yonghao

    2014-03-01

    This work investigated the feasibility of recovering and concentrating sugars and acetic acid (HAc) from prehydrolysis liquor (PHL) of the kraft-based dissolving pulp process prior to fermentation of hemicellulosic sugars, by the combination of activated carbon adsorption, nanofiltration (NF) and reverse osmosis (RO) processes. To reduce the fouling PHL was subjected to adsorption on activated carbon, then the treated PHL (TPHL) passed through a nanofiltration (NF DK) membrane to retain the sugars, and the permeate of acetic acid rich solution was passed through a reverse osmosis membrane (RO SG). It was found that for NF process sugars were concentrated from 48 to 227g/L at a volume reduction factor (VRF) of 5 while 80 to 90% of acetic acid was permeated. For the reverse osmosis process, 68% of acetic acid retention was achieved at pH 4.3 and 500 psi pressure and the HAc concentration increased from 10 to 50g/L. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  17. The drawbacks of using intermittent doses of sodium hypochlorite as an oxidising biocides in the pre-treatment line of a reverse osmosis desalination plant; Inconvenientes de realizar dosificacion intermitente de hipoclorito de sodio (biocida oxidante), en linea de pretratamiento de una plant desaladora por osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Elguera, A.; Alday Ansola, J.; Gomez Gotor, A.; Perez Baez, S. O.

    2001-07-01

    This article reports on the adverse effects on the microbiological quality of sea water with a high degree of biological contamination captured by an open intake system when it is subjected to intermittent, or shock, treatment, doses of an oxidising biocides, such as sodium hypochlorite NaClO (Kmm O4, O3, H2, O2), even through the purpose is to control microbiological development in the process water that contaminates the conduits, the units in which the processes are carried out and/or the unit operations, especially inside the membrane modules used in potabilising plants to desalt sea water and/or brackish water by the reverse osmosis technique. The uncontrolled development of a great diversity of microorganisms on the active layer of the membranes causes serious problems in the operation of this type of potabilising plant. (Author) 13 refs.

  18. In-depth analyses of organic matters in a full-scale seawater desalination plant and an autopsy of reverse osmosis membrane

    KAUST Repository

    Jeong, Sanghyun

    2016-02-17

    In order to facilitate the global performance of seawater reverse osmosis (SWRO) systems, it is important to improve the feed water quality before it enters the RO. Currently, many desalination plants experience production losses due to incidents of organic and biofouling. Consequently, monitoring or characterizing the pretreatment step using more advanced organic and biological parameters are required for better operation to lessen fouling issues. In this study, the performance of pretreatment processes (including coagulation, dual media filtration (DMF), polishing with cartridge filter (CF) coupled with anti-scalant) used at Perth Seawater Desalination Plant (PSDP) located in Western Australia were characterized in terms of organic and biological fouling parameters. These analyses were carried out using liquid chromatography with organic carbon detector (LC-OCD), three dimensional-fluorescence excitation emission matrix (3D-FEEM) and assimilable organic carbon (AOC). Furthermore, the used (exhausted) RO membrane and CF were autopsied so that the fates and behaviors of organic foulants in these treatment systems could be better understood.

  19. Dynamics of microbial communities in an integrated ultrafiltration–reverse osmosis desalination pilot plant located at the Arabian Gulf

    KAUST Repository

    Hong, Pei-Ying

    2015-08-27

    This study demonstrated the use of high-throughput sequencing to assess the efficacy of an integrated ultrafiltration (UF)–reverse osmosis (RO) desalination pilot plant located at the Arabian Gulf, and to identify potential microbial-associated problems that may arise in this plant. When integrated into the desalination treatment system, the UF membranes were able to serve as a good pretreatment strategy to delay RO fouling by achieving up to 1.96-log removal of cells from the seawater. Consequently, the differential pressure of the RO membrane remained around 1 bar for the entire six-month study, suggesting no significant biofouling performance issue identified for this RO system. Examples of microbial populations effectively removed by the UF membranes from the feed waters included Nitrosoarchaeum limnia and phototrophic eukaryotes. Microbial-associated problems observed in this pilot plant included the presence of Pseudomonas spp. in coexistence with Desulfovibrio spp. These two bacterial populations can reduce sulfate and produce hydrogen sulfide, which would in turn cause corrosion problems or compromise membrane integrities. Chemical-enhanced backwashing (CEB) can be used as an effective strategy to minimize the associated microbial problems by removing bacterial populations including sulfate reducers from the UF membranes.

  20. Paracetamol biodegradation by activated sludge and photocatalysis and its removal by a micelle-clay complex, activated charcoal, and reverse osmosis membranes.

    Science.gov (United States)

    Karaman, Rafik; Khamis, Mustafa; Abbadi, Jehad; Amro, Ahmad; Qurie, Mohannad; Ayyad, Ibrahim; Ayyash, Fatima; Hamarsheh, Omar; Yaqmour, Reem; Nir, Shlomo; Bufo, Sabino A; Scrano, Laura; Lerman, Sofia; Gur-Reznik, Shirra; Dosoretz, Carlos G

    2016-10-01

    Kinetic studies on the stability of the pain killer paracetamol in Al-Quds activated sludge demonstrated that paracetamol underwent biodegradation within less than one month to furnish p-aminophenol in high yields. Characterizations of bacteria contained in Al-Quds sludge were accomplished. It was found that Pseudomonas aeruginosa is the bacterium most responsible for the biodegradation of paracetamol to p-aminophenol and hydroquinone. Batch adsorptions of paracetamol and its biodegradation product (p-aminophenol) by activated charcoal and a composite micelle (octadecyltrimethylammonium)-clay (montmorillonite) were determined at 25°C. Adsorption was adequately described by a Langmuir isotherm, and indicated better efficiency of removal by the micelle-clay complex. The ability of bench top reverse osmosis (RO) plant as well as advanced membrane pilot plant to remove paracetamol was also studied at different water matrixes to test the effect of organic matter composition. The results showed that at least 90% rejection was obtained by both plants. In addition, removal of paracetamol from RO brine was investigated by using photocatalytic processes; optimal conditions were found to be acidic or basic pH, in which paracetamol degraded in less than 5 min. Toxicity studies indicated that the effluent and brine were not toxic except for using extra low energy membrane which displayed a half maximal inhibitory concentration (IC-50) value of 80%.

  1. Osmosis at constant volume and water uptake in tall trees

    OpenAIRE

    Zupanovic, Pasko; Brumen, Milan; Fajmut, Ales; Kuic, Domagoj; Juretic, Davor

    2009-01-01

    We consider a thermodynamic state of a solvent and solution separated with an elastic semipermeable membrane in a box with a constant volume and the relevance of this simple model for the water uptake in tall trees. Under moderate concentrations of a solute, the solution and solvent are under the positive and negative pressure, respectively. In the case of the soft membrane the pressure difference between the compartments with the solvent and solution is given by van't Hoff equation. A state ...

  2. Prediction of the rejection of organic compounds (neutral and ionic) by nanofiltration and reverse osmosis membranes using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Ammi, Yamina; Khaouane, Latifa; Hanini, Salah [University of Medea, Medea (Algeria)

    2015-11-15

    This work investigates the use of neural networks in modeling the rejection processes of organic compounds (neutral and ionic) by nanofiltration and reverse osmosis membranes. Three feed-forward neural network (NN) models, characterized by a similar structure (eleven neurons for NN1 and NN2 and twelve neurons for NN3 in the input layer, one hidden layer and one neuron in the output layer), are constructed with the aim of predicting the rejection of organic compounds (neutral and ionic). A set of 956 data points for NN1 and 701 data points for NN2 and NN3 were used to test the neural networks. 80%, 10%, and 10% of the total data were used, respectively, for the training, the validation, and the test of the three models. For the most promising neural network models, the predicted rejection values of the test dataset were compared to measured rejections values; good correlations were found (R= 0.9128 for NN1, R=0.9419 for NN2, and R=0.9527 for NN3). The root mean squared errors for the total dataset were 11.2430% for NN1, 9.0742% for NN2, and 8.2047% for NN3. Furthermore, the comparison between the predicted results and QSAR models shows that the neural network models gave far better.

  3. Advanced oxidation of iodinated X-ray contrast media in reverse osmosis brines: the influence of quenching.

    Science.gov (United States)

    Azerrad, Sara P; Gur-Reznik, Shirra; Heller-Grossman, Lilly; Dosoretz, Carlos G

    2014-10-01

    Among the main restrictions for the implementation of advanced oxidation processes (AOPs) for removal of micropollutants present in reverse osmosis (RO) brines of secondary effluents account the quenching performed by background organic and inorganic constituents. Natural organic matter (NOM) and soluble microbial products (SMP) are the main effluent organic matter constituents. The inorganic fraction is largely constituted by chlorides and bicarbonate alkalinity with sodium and calcium as main counterions. The quenching influence of these components, separately and their mixture, in the transformation of model compounds by UVA/TiO2 was studied applying synthetic brines solutions mimicking 2-fold concentrated RO secondary effluents brines. The results were validated using fresh RO brines. Diatrizoate (DTZ) and iopromide (IOPr) were used as model compound. They have been found to exhibit relative high resistance to oxidation process and therefore represent good markers for AOPs techniques. Under the conditions applied, oxidization of DTZ in the background of RO brines was strongly affected by quenching effects. The major contribution to quenching resulted from organic matter (≈70%) followed by bicarbonate alkalinity (≈30%). NOM displayed higher quenching than SMP in spite of its relative lower concentration. Multivalent cations, i.e., Ca(+2), were found to decrease effectiveness of the technique due to agglomeration of the catalyst. However this influence was lowered in presence of NOM. Different patterns of transformation were found for each model compound in which a delayed deiodination was observed for iopromide whereas diatrizoate oxidation paralleled deiodination. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Dynamics of biofilm formation under different nutrient levels and the effect on biofouling of a reverse osmosis membrane system.

    Science.gov (United States)

    Chen, Xi; Suwarno, Stanislaus Raditya; Chong, Tzyy Haur; McDougald, Diane; Kjelleberg, Staffan; Cohen, Yehuda; Fane, Anthony G; Rice, Scott A

    2013-01-01

    Pseudomonas aeruginosa PAO1 wild type and a mucoid derivative (FRD1) which over produces alginate were used to foul reverse osmosis (RO) membranes. When operated at a constant flux, biofilm formation on the RO membrane resulted in a slow rise in transmembrane pressure (TMP) of 22% for the initial four days of operation, followed by a sharp increase of 159% over the following two days. The initial slow increase in TMP was probably due to the formation of a biofilm on the membrane surface, which then accelerated the rate of biofouling through the effect of concentration polarization. At later stages of operation, most of the bacterial biomass consisted of dead cells. The amount of extracellular polymeric substances appeared to correlate positively with the number of dead cells. The results indicate that prolonging the initial stage of slow TMP increase and avoiding the latter stage of accelerated TMP increase would provide a sustainable operation of the RO system. These results suggest that nutrient limitation could reduce biofilm accumulation and delay the increase in TMP.

  5. Interactions of Organics within Hydrated Selective Layer of Reverse Osmosis Desalination Membrane: A Combined Experimental and Computational Study.

    Science.gov (United States)

    Ghoufi, Aziz; Dražević, Emil; Szymczyk, Anthony

    2017-03-07

    In this work we have examined a computational approach in predicting the interactions between uncharged organic solutes and polyamide membranes. We used three model organic molecules with identical molecular weights (100.1 g/mol), 4-aminopiperidine, 3,3-dimethyl-2-butanone (pinacolone) and methylisobutyl ketone for which we obtained experimental data on partitioning, diffusion and separation on a typical seawater reverse osmosis (RO) membrane. The interaction energy between the solutes and the membrane phase (fully aromatic polyamide) was computed from molecular dynamics (MD) simulations and the resulting sequence was found to correlate well with the experimental rejections and sorption data. Sorption of the different organic solutes within the membrane skin layer determined from attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) nicely agreed with interaction energies computed from molecular simulations. Qualitative information about solute diffusivity inside the membrane was also extracted from MD simulations while ATR-FTIR experiments indicated strongly hindered diffusion with diffusion coefficients in the membrane about 10-15 m2/s. The computational approach presented here could be a first step toward predicting rejections trends of, for example, hormones and pharmaceuticals by RO dense membranes.

  6. Removal of nitrogen compounds from landfill leachate using reverse osmosis with leachate stabilization in a buffer tank.

    Science.gov (United States)

    Talalaj, Izabela Anna

    2015-01-01

    In this paper, a removal of nitrogen compounds from a landfill leachate during reverse osmosis (RO) was evaluated. The treatment facility consists of a buffer tank and a RO system. The removal rate of N─NH4, [Formula: see text] and [Formula: see text] in the buffer tank reached 14%, 91% and 41%, respectively. The relatively low concentration of organic carbon limits N─NH4 oxidation in the buffer tank. The removal rate for the total organic nitrogen (TON) was 47%. The removal rate in RO was 99% for [Formula: see text], 84.1% for [Formula: see text] and 41% for [Formula: see text]. The accumulation of [Formula: see text] may be the result of a low pH, which before the RO process is reduced to a value of 6.0-6.5. Besides it, the cause for a low removal rate of the [Formula: see text] in the buffer tank and during RO may be free ammonia, which can inhibit the [Formula: see text] oxidation. The removal rates of total inorganic nitrogen and TON in the RO treatment facility were similar being 99% and 98.5%, respectively.

  7. Electrochemical treatment of reverse osmosis concentrate on boron-doped electrodes in undivided and divided cell configurations.

    Science.gov (United States)

    Bagastyo, Arseto Y; Batstone, Damien J; Kristiana, Ina; Escher, Beate I; Joll, Cynthia; Radjenovic, Jelena

    2014-08-30

    An undivided electrolytic cell may offer lower electrochlorination through reduction of chlorine/hypochlorite at the cathode. This study investigated the performance of electrooxidation of reverse osmosis concentrate using boron-doped diamond electrodes in membrane-divided and undivided cells. In both cell configurations, similar extents of chemical oxygen demand and dissolved organic carbon removal were obtained. Continuous formation of chlorinated organic compounds was observed regardless of the membrane presence. However, halogenation of the organic matter did not result in a corresponding increase in toxicity (Vibrio fischeri bioassay performed on extracted samples), with toxicity decreasing slightly until 10AhL(-1), and generally remaining near the initial baseline-toxicity equivalent concentration (TEQ) of the raw concentrate (i.e., ∼2mgL(-1)). The exception was a high range toxicity measure in the undivided cell (i.e., TEQ=11mgL(-1) at 2.4AhL(-1)), which rapidly decreased to 4mgL(-1). The discrepancy between the halogenated organic matter and toxicity patterns may be a consequence of volatile and/or polar halogenated by-products formed in oxidation by OH electrogenerated at the anode. The undivided cell exhibited lower energy compared to the divided cell, 0.25kWhgCOD(-1) and 0.34kWhgCOD(-1), respectively, yet it did not demonstrate any improvement regarding by-products formation. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Reverse osmosis as a potential technique to improve antioxidant properties of fruit juices used for functional beverages.

    Science.gov (United States)

    Gunathilake, K D P P; Yu, Li Juan; Rupasinghe, H P Vasantha

    2014-04-01

    Reverse osmosis (RO) as a potential technique to improve the antioxidant properties of cranberry, blueberry and apple juices was evaluated for the formulation of a functional beverage. The effects of temperature (20-40 °C) and trans-membrane pressure (25-35 bars) on physico-chemical and antioxidant properties of fruit juices were evaluated to optimize the operating parameters for each fruit juice. There was no significant effect on any quality parameters of fruit juices under studied operating parameters of RO. However, total soluble solid, total acidity and colour (a(∗)) of the concentrated juices increased in proportion to their volumetric concentrations. Antioxidant capacity measured by FRAP assay of concentrated apple, blueberry and cranberry juice was increased by 40%, 34%, and 30%, respectively. LDL oxidation inhibition by concentrated blueberry and cranberry juice was increased up to 41% and 45%, respectively. The results suggest that RO can be used for enhancing the health promoting properties of fruit juices. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Effect of coagulation on treatment of municipal wastewater reverse osmosis concentrate by UVC/H2O2.

    Science.gov (United States)

    Umar, Muhammad; Roddick, Felicity; Fan, Linhua

    2014-02-15

    Disposal of reverse osmosis concentrate (ROC) is a growing concern due to potential health and ecological risks. Alum coagulation was investigated as pre-treatment for the UVC/H2O2 treatment of two high salinity ROC samples (ROC A and B) of comparable organic and inorganic content. Coagulation removed a greater fraction of the organic content for ROC B (29%) than ROC A (16%) which correlated well with the reductions of colour and A254. Although the total reductions after 60 min UVC/H2O2 treatment with and without coagulation were comparable, large differences in the trends of reduction were observed which were attributed to the different nature of the organic content (humic-like) of the samples as indicated by the LC-OCD analyses and different initial (5% and 16%) biodegradability. Coagulation and UVC/H2O2 treatment preferentially removed humic-like compounds which resulted in low reaction rates after UVC/H2O2 treatment of the coagulated samples. The improvement in biodegradability was greater (2-3-fold) during UVC/H2O2 treatment of the pre-treated samples than without pre-treatment. The target DOC residual (≤ 15 mg/L) was obtained after 30 and 20 min irradiation of pre-treated ROC A and ROC B with downstream biological treatment, corresponding to reductions of 55% and 62%, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Reuse of olive mill effluents from two-phase extraction process by integrated advanced oxidation and reverse osmosis treatment.

    Science.gov (United States)

    Ochando-Pulido, J M; Hodaifa, G; Victor-Ortega, M D; Rodriguez-Vives, S; Martinez-Ferez, A

    2013-12-15

    In this work, complete reclamation of the olive mill effluents coming from a two-phase olive oil extraction process (OME-2) was studied on a pilot scale. The developed depuration procedure integrates an advanced oxidation process based on Fenton's reagent (secondary treatment) coupled with a final reverse osmosis (RO) stage (purification step). The former aims for the removal of the major concentration of refractory organic pollutants present in OME-2, whereas the latter provides efficient purification of the high salinity. Complete physicochemical composition of OME-2 after the secondary treatment was examined, including the particle size distribution, organic matter gradation and bacterial growth, in order to assess the selection of the membrane and its fouling propensity. Hydrodynamics and selectivity of the membrane were accurately modelized. Upon optimization of the hydrodynamic conditions, the RO membrane showed stable performance and fouling problems were satisfactorily overcome. Steady-state permeate flux equal to 21.1 L h(-1)m(-2) and rejection values up to 99.1% and 98.1% of the organic pollutants and electroconductivity were respectively attained. This ensured parametric values below standard limits for reuse of the regenerated effluent, e.g. in the olives washing machines, offering the possibility of closing the loop and thus rending the production process environmentally friendly. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Development of wet-dry reversible reverse osmosis membrane with high performance from cellulose acetate and cellulose triactate blend

    NARCIS (Netherlands)

    Vasarhelyi, K.; Ronner, J.A.; Mulder, M.H.V.; Smolders, C.A.

    1987-01-01

    Wet-dry reversible membrane were prepared bt a two-step coagulation procedure. A cast film containing a blend of cellulose triacetate as polymers, dioxane and acetone as solvents and maleic acid and methanol as additives was immersed consecutively in two aqueous coagulation baths, the first bath

  12. Biological Water Processor and Forward Osmosis Secondary Treatment

    Science.gov (United States)

    Shull, Sarah; Meyer, Caitlin

    2014-01-01

    The goal of the Biological Water Processor (BWP) is to remove 90% organic carbon and 75% ammonium from an exploration-based wastewater stream for four crew members. The innovative design saves on space, power and consumables as compared to the ISS Urine Processor Assembly (UPA) by utilizing microbes in a biofilm. The attached-growth system utilizes simultaneous nitrification and denitrification to mineralize organic carbon and ammonium to carbon dioxide and nitrogen gas, which can be scrubbed in a cabin air revitalization system. The BWP uses a four-crew wastewater comprised of urine and humidity condensate, as on the ISS, but also includes hygiene (shower, shave, hand washing and oral hygiene) and laundry. The BWP team donates 58L per day of this wastewater processed in Building 7.

  13. Membrane Bioreactor/Ultra Low Energy Reverse Osmosis Membrane Process for Forward Operating Base Wastewater Reuse

    Science.gov (United States)

    2014-08-01

    Synthetic Gray Water Recipe 2 (SynGW2) [30] Synthetic Gray Water Recipe 3 (SynGW3) Synthetic Gray Water Recipe 4 (SynGW4) [31] Ingredient mL/L...Forward Operating Bases (FOBs) require 25-60 gallons of potable water per soldier per day for essentials including drinking, hygiene, and food ...4.2.2. Characteristics of gray water 49 4.2.3 Synthetic gray water characterization 52 4.2.4 Evaluate MBR pre-treatment of synthetic gray water using

  14. Size effects of pore density and solute size on water osmosis through nanoporous membrane.

    Science.gov (United States)

    Zhao, Kuiwen; Wu, Huiying

    2012-11-15

    Understanding the behavior of osmotic transport across nanoporous membranes at molecular level is critical to their design and applications, and it is also beneficial to the comprehension of the mechanism of biological transmembrane transport processes. Pore density is an important parameter for nanoporous membranes. To better understand the influence of pore density on osmotic transport, we have performed systematic molecular dynamics simulations on water osmosis across nanoporous membranes with different pore densities (i.e., number of pores per unit area of membrane). The simulation results reveal that significant size effects occur when the pore density is so high that the center-to-center distance between neighboring nanopores is comparable to the solute size. The size effects are independent of the pore diameter and solute concentration. A simple quantitative correlation between pore density, solute size, and osmotic flux has been established. The results are excellently consistent with the theoretical predictions. It is also shown that solute hydration plays an important role in real osmotic processes. Solute hydration strengthens the size effects of pore density on osmotic processes due to the enlarged effective solute size induced by hydration. The influence of pore density, solute size, and solute hydration on water osmosis through nanoporous membranes can be introduced to eliminate the deviations of real osmotic processes from ideal behavior.

  15. Theoretical and experimental studies of reverse osmosis separation of inorganic salts in aqueous solutions; Estudio teorico y experimental de parametros de transporte a traves de membranas de osmosis inversa : Efecto de varios tipos de sales

    Energy Technology Data Exchange (ETDEWEB)

    Khavet, M.; Mengual, J. I.

    2004-07-01

    Theoretical and experimental studies of reverse osmosis separation of inorganic salts in aqueous solutions have been carried out. In this study, a polyamide thin film composite membrane in spiral wound configuration was used. The free energy of different inorganic monovalent (LiCl, NaCl, KCl, NaBr, NaI, LiBr, KBr) and divalent (MgCl2, MnCl2, CaCl2, MgBr2) salts has been calculated. The solute transport parameters were related to the free energy of the corresponding cations and anions. The mass transfer coefficient at the high pressure feed side of the spiral wound module was determined for each type of salt. The obtained theoretical values were compared to the experimental ones. The good agreements observed between the experimental and theoretical results confirm the validity of the theoretical procedure, which may be applied in modelling solar reverse osmosis plants for the prediction of the separation factor of various types of inorganic salts. (Author)

  16. Integrated Disinfection Byproducts (DBPs) Mixtures Research: DBP Concentration via Reverse Osmosis Membrane Techniques

    Science.gov (United States)

    With the completion of the 4-lab project, the NOM concentration aspect of 4-lab is being continued with renewed focus on creating drinking water relevant freeze-dried NOM isolates that can be used for many drinking water research efforts from DBP investigations to water reuse inv...

  17. Highly permeable double-skinned forward osmosis membranes for anti-fouling in the emulsified oil-water separation process

    KAUST Repository

    Duong, Hoang Hanh Phuoc

    2014-04-15

    Forward osmosis (FO) has attracted wide attention in recent years. However, the FO performance may be restricted due to internal concentration polarization (ICP) and fast fouling propensity that occurs in the membrane sublayer. Particularly, these problems significantly affect the membrane performance when treating highly contaminated oily wastewater. Recently, double-skinned flat sheet cellulose acetate (CA) membranes consisting of two selective skins via the phase inversion method have demonstrated less ICP and fouling propensity over typical single-skinned membranes. However, these membranes exhibit low water fluxes of <12 LMH under 2 M NaCl draw solution. Therefore, a novel double-skinned FO membrane with a high water flux has been aimed for in this study for emulsified oil-water treatment. The double-skinned FO membrane comprises a fully porous sublayer sandwiched between (i) a truly dense skin for salt rejection and (ii) a fairly loose dense skin for emulsified oil particle rejection. The former dense skin is a polyamide synthesized via interfacial polymerization, while the latter one is a self-assembled sulfonated pentablock copolymer (Nexar copolymer) layer. The resultant double-skinned membrane exhibits a high water flux of 17.2 LMH and a low reverse salt transport of 4.85 gMH using 0.5 M NaCl as the draw solution and DI water as the feed. The double-skinned membrane outperforms the single-skinned membrane with much lower fouling propensity for emulsified oil-water separation. © 2014 American Chemical Society.

  18. Modeling the Effects of Changing Seasonal River Flow Rates on the Mixing of Reverse Osmosis Plant Effluent into the Pasquotank River in North Carolina

    Science.gov (United States)

    Fischer, K. M.; Hankinson, S. D.

    2004-12-01

    The goal of this research, begun Fall 2004, is to assess the seasonal impact of effluent from a reverse osmosis (RO) plant on the water of the Pasquotank River, a trunk river of Albemarle Sound in northeast North Carolina. Currently, the plant discharges about 103,000 gallons of high salinity (16 ppt) processed groundwater into Chantilly Bay in the Pasquotank River (0-3 ppt, depending on season) over an eight-hour operational day. The impact of the RO effluent on water chemistry and physical properties along the river bottom depends on the flow rate of the river. The Pasquotank is slower flowing (anecdotally, reverse flowing at times) during the generally dry summer season and faster flowing during the rainy winter season. This varying river flow rate may result in various effluent zones: a pool of effluent on the riverbed, a plume of effluent dissipating with downstream distance, or a minimal effluent signal near the outlet manifold. Modeling of seasonal data for the current rate of effluent discharge allows prediction of the effects of tripling the daily volume of RO plant discharge through round-the-clock plant operation, an outcome that seems likely in the near future due to residential growth in the county served by the plant. Data from fall and early winter 2004 will be presented. Water parameters (salinity/conductivity, temperature, pH, turbidity, Secchi depth, dissolved oxygen content, and dissolved major cation concentrations) are measured biweekly at nine surface stations (three water depths at each station) in the general vicinity of the effluent discharge outlet. Similar parameters are measured biweekly for Pasquotank River water at two stations upstream and two stations downstream of the outlet. River flow rates and discharge rates are measured weekly. The results of modeling using a two-end member mixing model and a normative analysis treatment will be presented. Additionally, modeling results for various possible changes (relocation of discharge

  19. Environmental assessment of desalination processes: Reverse osmosis and Memstill®

    NARCIS (Netherlands)

    Tarnacki, K.; Meneses, M.; Melin, T.; Medevoort, J. van; Jansen, A.

    2012-01-01

    Desalination becomes in many parts of the world and also in Europe a promising option to combat water stress in water scarce regions. However, also the question of sustainability and environmental impacts of this technology is in focus of numerous studies and discussions. Especially, the focus is

  20. Exergy analysis of micro-organic Rankine power cycles for a small scale solar driven reverse osmosis desalination system

    Energy Technology Data Exchange (ETDEWEB)

    Tchanche, B.F.; Lambrinos, Gr.; Frangoudakis, A.; Papadakis, G. [Department of Natural Resources and Agricultural Engineering, Agricultural University of Athens, 75 Iera Odos Street, 11855 Athens (Greece)

    2010-04-15

    Exergy analysis of micro-organic Rankine heat engines is performed to identify the most suitable engine for driving a small scale reverse osmosis desalination system. Three modified engines derived from simple Rankine engine using regeneration (incorporation of regenerator or feedliquid heaters) are analyzed through a novel approach, called exergy-topological method based on the combination of exergy flow graphs, exergy loss graphs, and thermoeconomic graphs. For the investigations, three working fluids are considered: R134a, R245fa and R600. The incorporated devices produce different results with different fluids. Exergy destruction throughout the systems operating with R134a was quantified and illustrated using exergy diagrams. The sites with greater exergy destruction include turbine, evaporator and feedliquid heaters. The most critical components include evaporator, turbine and mixing units. A regenerative heat exchanger has positive effects only when the engine operates with dry fluids; feedliquid heaters improve the degree of thermodynamic perfection of the system but lead to loss in exergetic efficiency. Although, different modifications produce better energy conversion and less exergy destroyed, the improvements are not significant enough and subsequent modifications of the simple Rankine engine cannot be considered as economically profitable for heat source temperature below 100 C. As illustration, a regenerator increases the system's energy efficiency by 7%, the degree of thermodynamic perfection by 3.5% while the exergetic efficiency is unchanged in comparison with the simple Rankine cycle, with R600 as working fluid. The impacts of heat source temperature and pinch point temperature difference on engine's performance are also examined. Finally, results demonstrate that energy analysis combined with the mathematical graph theory is a powerful tool in performance assessments of Rankine based power systems and permits meaningful comparison of

  1. Treatment of radioactive liquid effluents by reverse osmosis membranes: From lab-scale to pilot-scale.

    Science.gov (United States)

    Combernoux, Nicolas; Schrive, Luc; Labed, Véronique; Wyart, Yvan; Carretier, Emilie; Moulin, Philippe

    2017-10-15

    The recent use of the reverse osmosis (RO) process at the damaged Fukushima-Daiichi nuclear power plant generated a growing interest in the application of this process for decontamination purposes. This study focused on the development of a robust RO process for decontamination of two kinds of liquid effluents: a contaminated groundwater after a nuclear disaster and a contaminated seawater during a nuclear accident. The SW30 HR membrane was selected among other in this study due to higher retentions (96% for Cs and 98% for Sr) in a true groundwater. Significant fouling and scaling phenomenon, attributed to calcium and strontium precipitation, were evidenced in this work: this underscored the importance of the lab scale experiment in the process. Validation of the separation performances on trace radionuclides concentration was performed with similar retention around 96% between surrogates Cs (inactive) and 137 Cs (radioactive). The scale up to a 2.6 m 2 spiral wound membrane led to equivalent retentions (around 96% for Cs and 99% for Sr) but lower flux values: this underlined that the hydrodynamic parameters (flowrate/cross-flow velocity) should be optimized. This methodology was also applied on the reconstituted seawater effluent: retentions were slightly lower than for the groundwater and the same hydrodynamic effects were observed on the pilot scale. Then, ageing of the membrane through irradiation experiments were performed. Results showed that the membrane active layer composition influenced the membrane resistance towards γ irradiation: the SW30 HR membrane performances (retention and permeability) were better than the Osmonics SE at 1 MGy. Finally, to supplement the scale up approach, the irradiation of a spiral wound membrane revealed a limited effect on the permeability and retention. This indicated that irradiation conditions need to be controlled for a further development of the process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Enzymatic cleaning of biofouled thin-film composite reverse osmosis (RO) membrane operated in a biofilm membrane reactor.

    Science.gov (United States)

    Khan, Mohiuddin; Danielsen, Steffen; Johansen, Katja; Lorenz, Lindsey; Nelson, Sara; Camper, Anne

    2014-02-01

    Application of environmentally friendly enzymes to remove thin-film composite (TFC) reverse osmosis (RO) membrane biofoulants without changing the physico-chemical properties of the RO surface is a challenging and new concept. Eight enzymes from Novozyme A/S were tested using a commercially available biofouling-resistant TFC polyamide RO membrane (BW30, FilmTech Corporation, Dow Chemical Co.) without filtration in a rotating disk reactor system operated for 58 days. At the end of the operation, the accumulated biofoulants on the TFC RO surfaces were treated with the three best enzymes, Subtilisin protease and lipase; dextranase; and polygalacturonase (PG) based enzymes, at neutral pH (~7) and doses of 50, 100, and 150 ppm. Contact times were 18 and 36 h. Live/dead staining, epifluorescence microscopy measurements, and 5 μm thick cryo-sections of enzyme and physically treated biofouled membranes revealed that Subtilisin protease- and lipase-based enzymes at 100 ppm and 18 h contact time were optimal for removing most of the cells and proteins from the RO surface. Culturable cells inside the biofilm declined by more than five logs even at the lower dose (50 ppm) and shorter incubation period (18 h). Subtilisin protease- and lipase-based enzyme cleaning at 100 ppm and for 18 h contact time restored the hydrophobicity of the TFC RO surface to its virgin condition while physical cleaning alone resulted in a 50° increase in hydrophobicity. Moreover, at this optimum working condition, the Subtilisin protease- and lipase-based enzyme treatment of biofouled RO surface also restored the surface roughness measured with atomic force microscopy and the mass percentage of the chemical compositions on the TFC surface estimated with X-ray photoelectron spectroscopy to its virgin condition. This novel study will encourage the further development and application of enzymes to remove biofoulants on the RO surface without changing its surface properties.

  3. Electrochemical treatment of reverse osmosis concentrate on boron-doped electrodes in undivided and divided cell configurations

    Energy Technology Data Exchange (ETDEWEB)

    Bagastyo, Arseto Y. [Advanced Water Management Centre, The University of Queensland, St Lucia, QLD 4072 (Australia); Department of Environmental Engineering, Institut Teknologi Sepuluh Nopember, Surabaya 60111 (Indonesia); Batstone, Damien J. [Advanced Water Management Centre, The University of Queensland, St Lucia, QLD 4072 (Australia); Kristiana, Ina [Curtin Water Quality Research Centre, Resources and Chemistry Precinct, Department of Chemistry, Curtin University, Bentley, Perth, WA 6102 (Australia); Escher, Beate I. [National Research Centre for Environmental Toxicology (Entox), The University of Queensland, Brisbane, QLD 4108 (Australia); Joll, Cynthia [Curtin Water Quality Research Centre, Resources and Chemistry Precinct, Department of Chemistry, Curtin University, Bentley, Perth, WA 6102 (Australia); Radjenovic, Jelena, E-mail: j.radjenovic@uq.edu.au [Advanced Water Management Centre, The University of Queensland, St Lucia, QLD 4072 (Australia)

    2014-08-30

    Highlights: • 100% of COD and ∼70% of DOC was removed in both cell configurations. • ∼21.7 mg L{sup −1} of AOCl and ∼2.3 mg L{sup −1} of AOBr was formed regardless of the membrane use. • The TEQ was far lower than expected given the high AOCl concentrations. • The undivided cell consumed lower energy compared to the divided cell. - Abstract: An undivided electrolytic cell may offer lower electrochlorination through reduction of chlorine/hypochlorite at the cathode. This study investigated the performance of electrooxidation of reverse osmosis concentrate using boron-doped diamond electrodes in membrane-divided and undivided cells. In both cell configurations, similar extents of chemical oxygen demand and dissolved organic carbon removal were obtained. Continuous formation of chlorinated organic compounds was observed regardless of the membrane presence. However, halogenation of the organic matter did not result in a corresponding increase in toxicity (Vibrio fischeri bioassay performed on extracted samples), with toxicity decreasing slightly until 10 Ah L{sup −1}, and generally remaining near the initial baseline-toxicity equivalent concentration (TEQ) of the raw concentrate (i.e., ∼2 mg L{sup −1}). The exception was a high range toxicity measure in the undivided cell (i.e., TEQ = 11 mg L{sup −1} at 2.4 Ah L{sup −1}), which rapidly decreased to 4 mg L{sup −1}. The discrepancy between the halogenated organic matter and toxicity patterns may be a consequence of volatile and/or polar halogenated by-products formed in oxidation by OH· electrogenerated at the anode. The undivided cell exhibited lower energy compared to the divided cell, 0.25 kWh gCOD{sup −1} and 0.34 kWh gCOD{sup −1}, respectively, yet it did not demonstrate any improvement regarding by-products formation.

  4. Effect of silica fouling on the removal of pharmaceuticals and personal care products by nanofiltration and reverse osmosis membranes.

    Science.gov (United States)

    Lin, Yi-Li; Chiou, Jheng-Hong; Lee, Chung-Hsiang

    2014-07-30

    In this study, one reverse osmosis (XLE) and two nanofiltration (NF90 and NF270) membranes were fouled by silica to evaluate its effect on the flux decline as well as the removal of six pharmaceuticals and personal care products (PPCPs) including carbamazapine (CBZ), triclosan (TRI), ibuprofen (IBU), sulfadiazine (DIA), sulfamethoxazole (SMX) and sulfamethazine (SMZ) from pH 3 to 10. The membranes were characterized by physicochemical properties including hydrophobicity, surface morphology and PPCPs adsorption with or without the presence of silica fouling to validate the rejection mechanisms of PPCPs. The fouling mechanisms were investigated using the modified Hermia model. It was found that all membranes with silica fouling showed more severe permeate flux decline at low pHs (3 and 5) than at high pHs (8 and 10) by the decomposition of nonionized silica particles to form a dense gel layer on membrane surfaces, which was hard to be removed by backwash. Silica fouling rendered the membrane surface considerably more hydrophilic, and only IBU, TRI and SMZ were adsorbed on membranes. Silica fouling on tight membranes (NF90 and XLE) can promote rejection of most PPCPs because the dense fouling layer could supply membrane with synergistic steric hindrance to reduce the transportation of PPCPs across membrane surface, implying that size exclusion is the dominating mechanism. While for loose NF270, electrostatic repulsion dominates by enhanced rejection of PPCPs as pH increased. Although fouling layer could provide extr