WorldWideScience

Sample records for resting ejection fraction

  1. Ejection fraction response to exercise in patients with chest pain and normal coronary arteriograms

    International Nuclear Information System (INIS)

    Gibbons, R.L.; Lee, K.L.; Cobb, F.; Jones, R.H.

    1981-01-01

    In this study we describe the ejection fraction response to upright exercise using first-pass radionuclide angiocardiography in a group of 60 patients with chest pain, normal coronary ateriograms and normal resting ventricular function. A wide range of resting function (heart rate and ejection fraction) and exercise function (heart rate, ejection fraction, peak work load and estimated peak oxygen uptake) were measured. The ejection fraction response to exercise demonstrated wide variation, ranging from a decrease of 23% to an increase of 24%. Six of 22 clinical and radionuclide angiocardiographic variables (resting ejection fraction, peak work load, age, sex, body surface area and the change in end-diastolic volume index with exercise) were significant univariate predictors of the ejection fraction response to exercise. Multivariable analysis identified resting ejection fraction, the change in end-diastolic volume index with exercise and either sex or peak work load as variables that provided significant independent predictive information. These observations indicate that the ejection fraction response to exercise is a complex response that is influenced by multiple physiologic variables. The wide variation in this population suggests that the ejection fraction response to exercise is not a reliable test for the diagnosis of coronary artery disease because of its low specificity

  2. Right and left ventricular ejection fraction at rest and during exercise assessed with radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Dahlstroem, J.A.

    1982-01-01

    Right (RVEF) and left ventricular ejection fraction (LVEF) assessed with radionuclide angiocardiography were compared to simultaneously obtained catheterization results at rest and during exercise in patients with pulmonary hypertension and ischemic heart disease. Blood pool imaging was performed with red blood cells (RBC) labelled with 99 Tcsup(m) in vivo as this method gave more stable 99 Tcsup(m) levels in blood compared to 99 Tcsup(m)-labelled human serum albumin and because it was more convenient than labelling RBC in vitro. RVEF measured with first pass (FP) technique and equilibrium (EQ) technique correlated well at rest, r = 0.86, and during exercise, r = 0.91. The FP technique had the best reproducibility and reference values at rest were 49+-5 per cent increasing with exercise. When 99 Tcsup(m) and 133 Xe were compared to assess RVEF with FP technique, the correlation was good, r = 0.88. LVEF assessed with EQ technique and a fixed end-diastolic region of interest was very reproducible at rest and during exercise; reference values at rest were 56+-8 per cent increasing with exercise. In 10 patients with pulmonary hypertension significant negative correlations were found between RVEF assessed with FP technique and pressures in pulmonary artery and right atrium. Abnormal RVEF was found in all patients with right ventricular disfunction. In 22 patients with recent myocardial infarction measurements of LVEF detected left ventricular disfunction better than did measurement of pulmonary artery diastolic pressure. During effort angina in another 10 patients all had abnormal LVEF and abnormal hemodynamics. By combining ejection fraction and stroke volume, ventricular volumes were calculated at rest and during exercise. (author)

  3. Performance of a fully automated program for measurement of left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Douglass, K.H.; Tibbits, P.; Kasecamp, W.; Han, S.T.; Koller, D.; Links, J.M.; Wagner, H.H. Jr.

    1982-01-01

    A fully automated program developed by us for measurement of left ventricular ejection fraction from equilibrium gated blood studies was evaluated in 130 additional patients. Both of 6-min (130 studies) and 2-min (142 studies in 31 patients) gated blood pool studies were acquired and processed. The program successfully generated ejection fractions in 86% of the studies. These automatically generated ejection fractions were compared with ejection fractions derived from manually drawn regions the interest. When studies were acquired for 6-min with the patient at rest, the correlation between automated and manual ejection fractions was 0.92. When studies were acquired for 2-min, both at rest and during bicycle exercise, the correlation was 0.81. In 25 studies from patients who also underwent contrast ventriculography, the program successfully generated regions of interest in 22 (88%). The correlation between the ejection fraction determined by contrast ventriculography and the automatically generated radionuclide ejection fraction was 0.79. (orig.)

  4. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  5. Exercise testing in asymptomatic or minimally symptomatic aortic regurgitation: relationship of left ventricular ejection fraction to left ventricular filling pressure during exercise

    International Nuclear Information System (INIS)

    Boucher, C.A.; Wilson, R.A.; Kanarek, D.J.; Hutter, A.M. Jr.; Okada, R.D.; Liberthson, R.R.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise radionuclide angiography is being used to evaluate left ventricular function in patients with aortic regurgitation. Ejection fraction is the most common variable analyzed. To better understand the rest and exercise ejection fraction in this setting, 20 patients with asymptomatic or minimally symptomatic severe aortic regurgitation were studied. All underwent simultaneous supine exercise radionuclide angiography and pulmonary gas exchange measurement and underwent rest and exercise measurement of pulmonary artery wedge pressure (PAWP) during cardiac catheterization. Eight patients had a peak exercise PAWP less than 15 mm Hg (group 1) and 12 had a peak exercise PAWP greater than or equal to 15 mm Hg (group 2). Group 1 patients were younger and more were in New York Heart Association class I. The two groups had similar cardiothoracic ratios, changes in ejection fractions with exercise, and rest and exercise regurgitant indexes. Using multiple regression analysis, the best correlate of the exercise PAWP was peak oxygen uptake (r . -0.78, p less than 0.01). No other measurement added significantly to the regression. When peak oxygen uptake was excluded, rest and exercise ejection fraction also correlated significantly (r . -0.62 and r . -0.60, respectively, p less than 0.01). Patients with asymptomatic or minimally symptomatic severe aortic regurgitation have a wide spectrum of cardiac performance in terms of the PAWP during exercise. The absolute rest and exercise ejection fraction and the level of exercise achieved are noninvasive variables that correlate with exercise PAWP in aortic regurgitation, but the change in ejection fraction with exercise by itself is not

  6. Effect of exercise on circulating atrial natriuretic peptide and left ventricular ejection fraction in healthy persons and patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nakamura, Tetsuya; Ichikawa, Shuichi; Sakamaki, Tetsuo; Suzuki, Tadashi; Iizuka, Toshio; Yagi, Atsuko; Kurashina, Toshiaki; Kumakura, Hisao; Murata, Kazuhiko

    1988-01-01

    Radionuclide angiographic measurements of left ventricular ejection fraction were performed at rest and during exercise in 10 normal persons and 11 patients with coronary artery disease. Exercise was continued on a supine bicycle exercise table up to a symptom-limited maximum. Plasma levels of atrial natriuretic peptide (ANP) were also determined at rest and during exercise. Ejection fraction in the normal volunteers was 59±3% (mean±SEM) at rest and increased significantly (p<0.01) to 69±3% during exercise. Ejection fraction in the patients was 47±5% at rest and did not change significantly during exercise (51±7%). Plasma ANP in the normals rose significantly (p<0.01) from 62±16 pg/ml at rest to 454±94 pg/ml during exercise. Plasma ANP in the patients also rose significantly (p<0.01) from 231±102 pg/ml to 794±170 pg/ml. The response of plasma ANP to exercise was enhanced significantly (p<0.05) in the patients as compared with the normals in relation to ejection fraction by analysis of covariance. In both the normals and the patients, plasma ANP was inversely and significantly correlated with ejection fraction during exercise (r=0.46, p<0.05, n=21), however, not at rest. Because it has been reported that plasma ANP is correlated positively with pulmonary artery wedge pressure, the estimation of plasma ANP during an exercise stress test might be used for the evaluation of cardiac reserve in coronary artery disease. (author)

  7. Extracting and analyzing ejection fraction values from electronic echocardiography reports in a large health maintenance organization.

    Science.gov (United States)

    Xie, Fagen; Zheng, Chengyi; Yuh-Jer Shen, Albert; Chen, Wansu

    2017-12-01

    The left ventricular ejection fraction value is an important prognostic indicator of cardiovascular outcomes including morbidity and mortality and is often used clinically to indicate severity of heart disease. However, it is usually reported in free-text echocardiography reports. We developed and validated a computerized algorithm to extract ejection fraction values from echocardiography reports and applied the algorithm to a large volume of unstructured echocardiography reports between 1995 and 2011 in a large health maintenance organization. A total of 621,856 echocardiography reports with a description of ejection fraction values or systolic functions were identified, of which 70 percent contained numeric ejection fraction values and the rest (30%) were text descriptions explicitly indicating the systolic left ventricular function. The 12.1 percent (16.0% for male and 8.4% for female) of these extracted ejection fraction values are <45 percent. Validation conducted based on a random sample of 200 reports yielded 95.0 percent sensitivity and 96.9 percent positive predictive value.

  8. Aortic insufficiency and hydralazine: behaviour of left ventricular ejection fraction and of stroke index ratio at rest and during exercise

    International Nuclear Information System (INIS)

    Sole, C.; Florenzano, F.; Morales, B.; Neubauer, S.; Escobar, E.; Mollerach, F.; Mollerach, A.; Avella, O.

    1982-01-01

    The gated blood pool ventriculography in patients undergoing in vivo red blood cells labelling with 99mTc-pertechnetate, was evaluated critically as a form of quantifying aortic valvular regurgitation (AVR) and was applicated in severe aortic insufficiency (AI) to determine the effects of Hydralazine at rest and during exercise on the ventricular function parameters thus obtained. The beneficious effects of Hydralazine on left ventricular performance in patients with AI, have already been reported. The results confirm this too, but using a non-invasive method. These beneficious effects of Hydralazine in patients with AI were proved to be a consequence of significant increase in left ventricular ejection fraction (LVEF)

  9. Heart rate index: an indicator of left ventricular ejection fraction. Comparison of left ventricular ejection fraction and variables assessed by exercise test in patients studied early after acute myocardial infarction

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, Jesper Hastrup

    1992-01-01

    The present study compares the variables assessed by standard exercise test with the left ventricular ejection fraction (LVEF) measured by multigated radionuclide angiocardiography (MUGA) in 77 patients early after myocardial infarction. The exercise test and MUGA were performed within two weeks...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  10. Air pollution and heart failure: Relationship with the ejection fraction

    Science.gov (United States)

    Dominguez-Rodriguez, Alberto; Abreu-Afonso, Javier; Rodríguez, Sergio; Juarez-Prera, Ruben A; Arroyo-Ucar, Eduardo; Gonzalez, Yenny; Abreu-Gonzalez, Pedro; Avanzas, Pablo

    2013-01-01

    AIM: To study whether the concentrations of particulate matter in ambient air are associated with hospital admission due to heart failure in patients with heart failure with preserved ejection fraction and reduced ejection fraction. METHODS: We studied 353 consecutive patients admitted into a tertiary care hospital with a diagnosis of heart failure. Patients with ejection fraction of ≥ 45% were classified as having heart failure with preserved ejection fraction and those with an ejection fraction of < 45% were classified as having heart failure with reduced ejection fraction. We determined the average concentrations of different sizes of particulate matter (< 10, < 2.5, and < 1 μm) and the concentrations of gaseous pollutants (carbon monoxide, sulphur dioxide, nitrogen dioxide and ozone) from 1 d up to 7 d prior to admission. RESULTS: The heart failure with preserved ejection fraction population was exposed to higher nitrogen dioxide concentrations compared to the heart failure with reduced ejection fraction population (12.95 ± 8.22 μg/m3 vs 4.50 ± 2.34 μg/m3, P < 0.0001). Multivariate analysis showed that nitrogen dioxide was a significant predictor of heart failure with preserved ejection fraction (odds ratio ranging from (1.403, 95%CI: 1.003-2.007, P = 0.04) to (1.669, 95%CI: 1.043-2.671, P = 0.03). CONCLUSION: This study demonstrates that short-term nitrogen dioxide exposure is independently associated with admission in the heart failure with preserved ejection fraction population. PMID:23538391

  11. Sildenafil and diastolic dysfunction after acute myocardial infarction in patients with preserved ejection fraction

    DEFF Research Database (Denmark)

    Andersen, Mads J; Ersbøll, Mads; Axelsson, Anna

    2013-01-01

    with diastolic dysfunction after myocardial infarction. METHODS AND RESULTS: Seventy patients with diastolic dysfunction and near normal left ventricular ejection fraction on echocardiography were randomly assigned sildenafil 40 mg thrice daily or matching placebo for 9 weeks. Before randomization and after 9......, and systemic vascular resistance index (resting, P=0.0002; peak exercise, P=0.007) and diastolic blood pressure (resting, P=0.005; peak exercise, P=0.02) were lower in the sildenafil group. Resting left ventricular end-diastolic volume index increased (P=0.001) within the sildenafil group but was unchanged...

  12. Outcomes in Asymptomatic Severe Aortic Stenosis With Preserved Ejection Fraction Undergoing Rest and Treadmill Stress Echocardiography.

    Science.gov (United States)

    Huded, Chetan P; Masri, Ahmad; Kusunose, Kenya; Goodman, Andrew L; Grimm, Richard A; Gillinov, A Marc; Johnston, Douglas R; Rodriguez, L Leonardo; Popovic, Zoran B; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y

    2018-04-12

    In asymptomatic patients with severe aortic stenosis and preserved left ventricular ejection fraction, we sought to assess the incremental prognostic value of resting valvuloarterial impedence (Zva) and left ventricular global longitudinal strain (LV-GLS) to treadmill stress echocardiography. We studied 504 such patients (66±12 years, 78% men, 32% with coronary artery disease who underwent treadmill stress echocardiography between 2001 and 2012. Clinical and exercise variables (% of age-sex predicted metabolic equivalents [%AGP-METs]) were recorded. Resting Zva ([systolic arterial pressure+mean aortic valve gradient]/[LV-stroke volume index]) and LV-GLS (measured offline using Velocity Vector Imaging, Siemens) were obtained from the baseline resting echocardiogram. Death was the primary outcome. There were no major adverse cardiac events during treadmill stress echocardiography. Indexed aortic valve area, Zva, and LV-GLS were 0.46±0.1 cm 2 /m 2 , 4.5±0.9 mm Hg/mL per m 2 and -16±4%, respectively; only 50% achieved >100% AGP-METs. Sixty-four percent underwent aortic valve replacement. Death occurred in 164 (33%) patients over 8.9±3.6 years (2 within 30 days of aortic valve replacement). On multivariable Cox survival analysis, higher Society of Thoracic Surgeons score (hazard ratio or HR 1.06), lower % AGP-METS (HR 1.16), higher Zva (HR 1.25) and lower LV-GLS (HR 1.12) were associated with higher longer-term mortality, while aortic valve replacement (HR 0.45) was associated with improved survival (all P statistic from 0.65 to 0.69 and 0.75, respectively, both P stress echocardiography, LV-GLS and ZVa offer incremental prognostic value. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  13. Ultrasonographic ejection fraction of normal gallbladder

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hun; Kim, Seung Yup; Park, Yaung Hee; Kang, Ik Won; Yoon, Jong Sup [Hangang Sacred Heart Hospital, Halym College, Chuncheon (Korea, Republic of)

    1984-06-15

    Real-time ultrasonography is a simple, accurate, noninvasive and potentially valuable means of studying gallbladder size and emptying. The authors calculated ultrasonographically the ejection fraction of 80 cases of normally functioning gallbladder on oral cholecystography, from June 1983 to April 1984, at the department of radiology, Hangang Sacred Heart Hospital. The results were obtained as follows; 1. Ultrasonographic Ejection Fraction at 30 minutes after the fatty meal was 73.1{+-}16.85. 2. There was no significant difference in age and sex, statistically.

  14. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  15. Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Young Hee; Lee, Hae Giu; Lee, Sung Yong; Park, Suk Min; Chung, Soo Kyo; Yim, Jeong Ik; Bahk, Yong Whee; Shinn, Kyung Sub; Kim, Young Gyun; Kwon, Soon Seog [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1993-03-15

    Radionuclide cardioangiography has been widely applied and has played major roles in moninvasive assessment of cardiac function. Three techniques, first-pass gated first and gated equilibrium methods have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is most accurate method among the three techniques in assessment of fight ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there has been no published data of fight ejection fraction by the gated first pass method were compared with the defects from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows; 1) The values of fight ventricular ejection fraction by the gated first pass method were 50.1 +- 6.1% in normal subjects and 38.5 +- 8.5 in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p<0.05) 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated ith FEV{sub 1}, VC. DLCO. and FVC as well as P{sub a}O2 and P{sub a}CO2 of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  16. Characteristics and long-term prognosis of patients with heart failure and mid-range ejection fraction compared with reduced and preserved ejection fraction

    DEFF Research Database (Denmark)

    Lauritsen, Josephine; Gustafsson, Finn; Abdulla, Jawdat

    2018-01-01

    AIMS: This study aimed to assess by a meta-analysis the clinical characteristics, all-cause and cardiovascular mortality, and hospitalization of patients with heart failure (HF) with mid-range ejection fraction (HFmrEF) compared with HF with reduced ejection fraction (HFrEF) and HF with preserved...

  17. Left atrial function in heart failure with impaired and preserved ejection fraction.

    Science.gov (United States)

    Fang, Fang; Lee, Alex Pui-Wai; Yu, Cheuk-Man

    2014-09-01

    Left atrial structural and functional changes in heart failure are relatively ignored parts of cardiac assessment. This review illustrates the pathophysiological and functional changes in left atrium in heart failure as well as their prognostic value. Heart failure can be divided into those with systolic dysfunction and heart failure with preserved ejection fraction (HFPEF). Left atrial enlargement and dysfunction commonly occur in systolic heart failure, in particular, in idiopathic dilated cardiomyopathy. Atrial enlargement and dysfunction also carry important prognostic value in systolic heart failure, independently of known parameters such as left ventricular ejection fraction. In HFPEF, there is evidence of left atrial enlargement, impaired atrial compliance, and reduction of atrial pump function. This occurs not only at rest but also during exercise, indicating significant impairment of atrial contractile reserve. Furthermore, atrial dyssynchrony is common in HFPEF. These factors further contribute to the development of new onset or progression of atrial arrhythmias, in particular, atrial fibrillation. Left atrial function is an integral part of cardiac function and its structural and functional changes in heart failure are common. As changes of left atrial structure and function have different clinical implications in systolic heart failure and HFPEF, routine assessment is warranted.

  18. Hyperdynamic left ventricular ejection fraction in the intensive care unit.

    Science.gov (United States)

    Paonessa, Joseph R; Brennan, Thomas; Pimentel, Marco; Steinhaus, Daniel; Feng, Mengling; Celi, Leo Anthony

    2015-08-07

    Limited information exists on the etiology, prevalence, and significance of hyperdynamic left ventricular ejection fraction (HDLVEF) in the intensive care unit (ICU). Our aim in the present study was to compare characteristics and outcomes of patients with HDLVEF with those of patients with normal left ventricular ejection fraction in the ICU using a large, public, deidentified critical care database. We conducted a longitudinal, single-center, retrospective cohort study of adult patients who underwent echocardiography during a medical or surgical ICU admission at the Beth Israel Deaconess Medical Center using the Multiparameter Intelligent Monitoring in Intensive Care II database. The final cohort had 2867 patients, of whom 324 had HDLVEF, defined as an ejection fraction >70%. Patients with an ejection fraction <55% were excluded. Compared with critically ill patients with normal left ventricular ejection fraction, the finding of HDLVEF in critically ill patients was associated with female sex, increased age, and the diagnoses of hypertension and cancer. Patients with HDLVEF had increased 28-day mortality compared with those with normal ejection fraction in multivariate logistic regression analysis adjusted for age, sex, Sequential Organ Failure Assessment score, Elixhauser score for comorbidities, vasopressor use, and mechanical ventilation use (odds ratio 1.38, 95% confidence interval 1.039-1.842, p =0.02). The presence of HDLVEF portended increased 28-day mortality, and may be helpful as a gravity marker for prognosis in patients admitted to the ICU. Further research is warranted to gain a better understanding of how these patients respond to common interventions in the ICU and to determine if pharmacologic modulation of HDLVEF improves outcomes.

  19. The effects of stress on left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Kiess, M.C.; Dimsdale, J.E.; Moore, R.H.; Liu, P.; Newell, J.; Barlai-Kovach, M.; Boucher, C.A.; Strauss, H.W.; Massachusetts General Hospital, Boston; Massachusetts General Hospital, Boston

    1988-01-01

    The left ventricular ejection fraction (EF) was studied in 17 healthy volunteers with a new ambulatory left ventricular function monitor. Heart rate, EF, and blood pressure measurements were made during rest, a psychiatric stress interview, cold exposure, exercise, and eating. An increase in EF was seen during emotional stress (from 0.45±0.09 to 0.51±0.13, P<0.001). This increase was comparable to that observed during exercise (0.52±0.14) and eating (0.52±0.10, P<0.001). In contrast, cold exposure caused a decrease in EF (0.43±0.13, P<0.05). These observations demonstrate the powerful hemodynamic consequences of common behaviors as well as the utility and feasability of studying such behavioral factors in ambulatory subjects. (orig.)

  20. Regional ejection fraction: a quantitative radionuclide index of regional left ventricular performance

    International Nuclear Information System (INIS)

    Maddox, D.E.; Wynne, J.; Uren, R.; Parker, J.A.; Idoine, J.; Siegel, L.C.; Neill, J.M.; Cohn, P.F.; Holman, B.L.

    1979-01-01

    Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, modified left anterior oblique projection, the regional change in background corrected counts was determined in each of three anatomic regions. The normal range for regional radionuclide ejection fraction was determined in 10 patients with normal contrast ventriculograms and without obstructive coronary artery disease at coronary arteriography. Regional ejection fraction was compared with percent segmental axis shortening and extent of akinetic segments in corresponding regions of the contrast ventriculogram. Radionuclide and roentgenographic methods were in agreement as to the presence or absence of abnormal wall motion in 83 of 99 left ventricular regions (84%) in 33 patients evaluated prospectively. Comparison of regional ejection fraction demonstrated significant differences between regions with roentgenographically determined normokinesis hypokinesis, and akinesis. We conclude that the left ventricular regional ejection fraction provides a reliable quantitative assessment of regional left ventricular performance

  1. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    Energy Technology Data Exchange (ETDEWEB)

    de Vernejoul, P; Fauchet, M; Rimbert, J -N; Gambini, D; Agnely, J [Hopital Necker-Enfants-Malades, 75 - Paris (France)

    1976-03-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference.

  2. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    International Nuclear Information System (INIS)

    Vernejoul, Pierre de; Fauchet, Michel; Rimbert, J.-N.; Gambini, Denis; Agnely, Jacqueline

    1976-01-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference [fr

  3. Resting and exercise haemodynamics in relation to six-minute walk test in patients with heart failure and preserved ejection fraction

    DEFF Research Database (Denmark)

    Wolsk, Emil; Kaye, David; Borlaug, Barry A

    2018-01-01

    AIMS: Patients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, a...

  4. Factors influencing the variations of ejection fraction during exercise in chronic aortic regurgitation

    International Nuclear Information System (INIS)

    Bassand, J.P.; Faivre, R.; Berthout, P.; Maurat, J.P.; Cardot, J.C.; Verdenet, J.; Bidet, R.

    1987-01-01

    The influence of left ventricular volume variations and regurgitant fraction variations upon left ventricular ejection fraction during exercise was examined using equilibrium radionuclide angiography in patients suffering from aortic regurgitation. Ejection fraction (EF), regurgitant fraction (RF), end diastolic volume (EDV) and end systolic volume (ESV) variations from rest to peak exercise were determined in 44 patients suffering from chronic aortic regurgitation (AR) and in 8 healthy volunteers (C). In C, EF increased (+0.10±0.03, P<0.01) and ESV decreased significantly (-23%±12%, P<0.01), RF and EDV did not vary significantly. In AR patients, EF, EDV and ESV did not vary significantly because of important scattering of individual values. Changes in EF and ESV were inversely correlated (r=-0.79, P<0.01) and RF decreased significantly (-0.12±0.10, P<0.01). Volumes and EF changes during exercise occurred in three different ways. In a 1st subgroup of 7 patients, EF increased (+0.09±0.03, P<0.05) in conjunction with a reduction of ESV (-24%±12%, P<0.05) without a significant change in EDV. In a 2nd group of 22 patients, EF decreased (-0.04±0.07, P<0.01) in association with an increase in ESV (+17%±16%, P<0.01) and no changes in EDV. In a 3rd subgroup of 15 patients, EF decreased (-0.02±0.06, P<0.01) despite a reduction in ESV (-7%±6%, P<0.01) because of a dramatic EDV decrease (-10%±6%, P<0.05). In this subgroup, changes in EF were inversely correlated with changes in ESV (r=-0.55, P<0.01) and positively related to EDV variations (r=0.42, P=0.02). EDV changes were weakly, but significantly, correlated to RF decrease (r=0.39, P<0.05). We conclude that changes in left ventricular ejection fraction during exercise in patients with chronic aortic regurgitation are significantly related in some patients to changes in ventricular loading conditions as well as contractile state. (orig./MG)

  5. Quality of life is impaired similarly in heart failure patients with preserved and reduced ejection fraction

    NARCIS (Netherlands)

    Hoekstra, Tialda; Lesman-Leegte, Ivonne; van Veldhuisen, Dirk J.; Sanderman, Robbert; Jaarsma, Tiny

    Aims To compare quality of life (QoL) in heart failure (HF) patients with preserved ejection fraction (HF-PEF) and HF patients with reduced ejection fraction (HF-REF) in a well-defined HF population. Methods and results Patients with HF-PEF [left ventricular ejection fraction (LVEF) >= 40%] were

  6. Hemodynamic Characteristics in Significant Symptomatic and Asymptomatic Primary Mitral Valve Regurgitation at Rest and during Exercise

    DEFF Research Database (Denmark)

    Bakkestrøm, Rine; Banke, Ann; Christensen, Nicolaj L.

    2018-01-01

    ventricular ejection fraction, >60%) were included. Right heart catheterization during rest and exercise, echocardiography, magnetic resonance imaging, and peak oxygen consumption test was performed. Symptomatic subjects had significantly higher pulmonary capillary wedge pressure at rest (14±4 versus 11±3 mm...... mean PAP and left ventricular ejection fraction (r=-0.52; P=0.02) and right ventricular ejection fraction (r=-0.67; Pequal and normal in both groups and correlated with left ventricular stroke volume but not with pulmonary capillary wedge pressure. Conclusions...

  7. Ejection fraction improvement and reverse remodeling achieved with Sacubitril/Valsartan in heart failure with reduced ejection fraction patients.

    Science.gov (United States)

    Almufleh, Aws; Marbach, Jeffrey; Chih, Sharon; Stadnick, Ellamae; Davies, Ross; Liu, Peter; Mielniczuk, Lisa

    2017-01-01

    Sacubitril/Valsartan has been shown to improve mortality and reduce hospitalizations in patients with heart failure with reduced ejection fraction (HFrEF). The effect of Sacubitril/Valsartan on ejection fraction (EF) and reverse remodeling parameters have not been previously described. We performed a single-center, retrospective, cohort study of HFrEF patients (n=48) who were treated with Sacubitril/Valsartan for a median duration of 3 months (Interquartile range 2-6 months). Clinical and echocardiographic parameters were reviewed at three time points (pre-baseline which was median of 18 months before starting Sacubitril/Valsartan, baseline before treatment started, and post-Sacubitril/Valsartan). Paired sample t-test and one-way repeated measures ANOVA were used for normally distributed data, while Wilcoxon Signed Rank test for non-normally distributed data. Sacubitril/Valsartan use was associated with an average 5% (±1.2) increase in EF, from a mean baseline of 25.33% to 30.14% (pSacubitril/Valsartan was found to improve EF and multiple measures of reverse remodeling beyond the effects of concomitant optimal medical therapy. Though these results are encouraging, our small sample, observational study requires confirmation in larger cohorts with longer follow-up periods.

  8. Heart failure with preserved ejection fraction in women : The dutch queen of hearts program

    NARCIS (Netherlands)

    den Ruijter, H.; Pasterkamp, G.; Rutten, F. H.; Lam, C. S P; Chi, C.; Tan, K. H.; van Zonneveld, A. J.; Spaanderman, M.; de Kleijn, D. P V

    2015-01-01

    Heart failure (HF) poses a heavy burden on patients, their families and society. The syndrome of HF comes in two types: with reduced ejection fraction (HFrEF) and preserved ejection fraction (HFpEF). The latter is on the increase and predominantly present in women, especially the older ones. There

  9. Differing prognostic value of pulse pressure in patients with heart failure with reduced or preserved ejection fraction

    DEFF Research Database (Denmark)

    Jackson, Colette E; Castagno, Davide; Maggioni, Aldo P

    2015-01-01

    ) and 5008 with HF-PEF (828 deaths). Pulse pressure was analysed in quintiles in a multivariable model adjusted for the previously reported Meta-Analysis Global Group in Chronic Heart Failure prognostic variables. Heart failure and reduced ejection fraction patients in the lowest pulse pressure quintile had...... in patients with HF-PEF [ejection fraction (EF) ≥ 50%] and HF-REF. METHODS AND RESULTS: Data from 22 HF studies were examined. Preserved left ventricular ejection fraction (LVEF) was defined as LVEF ≥ 50%. All-cause mortality at 3 years was evaluated in 27 046 patients: 22 038 with HF-REF (4980 deaths......AIMS: Low pulse pressure is a marker of adverse outcome in patients with heart failure (HF) and reduced ejection fraction (HF-REF) but the prognostic value of pulse pressure in patients with HF and preserved ejection fraction (HF-PEF) is unknown. We examined the prognostic value of pulse pressure...

  10. Value of exercise echocardiography in heart failure with preserved ejection fraction: a substudy from the KaRen study.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Reynaud, Amélie; Schnell, Frédéric; Persson, Hans; Drouet, Elodie; Linde, Cecilia; Daubert, Claude

    2016-01-01

    KaRen is a multicentre study designed to characterize and follow patients with heart failure and preserved ejection fraction (HFpEF). In a subgroup of patients with clinical signs of congestion but left ventricular ejection fraction (LVEF) >45%, we sought to describe and analyse the potential prognostic value of echocardiographic parameters recorded not only at rest but also during a submaximal exercise stress echocardiography. Exercise-induced changes in echo parameters might improve our ability to characterize HFpEF patients. Patients were prospectively recruited in a single tertiary centre following an acute HF episode with NT-pro-BNP >300 pg/mL (BNP > 100 pg/mL) and LVEF > 45% and reassessed by exercise echo-Doppler after 4-8 weeks of dedicated treatment. Image acquisitions were standardized, and analysis made at end of follow-up blinded to patients' clinical status and outcome. In total, 60 patients having standardized echocardiographic acquisitions were included in the analysis. Twenty-six patients (43%) died or were hospitalized for HF (primary outcome). The mean ± SD workload was 45 ± 14 watts (W). Mean ± SD resting LVEF and LV global longitudinal strain was 57.6 ± 9.5% and -14.5 ± 4.2%, respectively. Mean ± SD resting E/e' was 11.3 ± 4.7 and 13.1 ± 5.3 in those patients who did not and those who did experience the primary outcome, respectively (P = 0.03). Tricuspid regurgitation (TR) peak velocity during exercise were 3.3 ± 0.5 and 3.7 ± 0.5 m/s (P = 0.01). Exercise TR was independently associated with HF-hospitalization or death after adjustment on baseline clinical and biological characteristics. Exercise echocardiography may contribute to identify HFpEF patients and especially high-risk ones. Our study suggested a prognostic value of TR recorded during an exercise. That was demonstrated independently of the value of resting E/e'. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions

  11. Right ventricular ejection fraction: an indicator of increased mortality in patients with congestive heart failure associated with coronary artery disease

    International Nuclear Information System (INIS)

    Polak, J.F.; Holman, B.L.; Wynne, J.; Colucci, W.S.

    1983-01-01

    The predictive value of radionuclide ventriculography was studied in 34 patients with depressed left ventricular ejection fraction (less than 40%) and clinically evident congestive heart failure secondary to atherosclerotic coronary artery disease. In addition to left ventricular ejection fraction, right ventricular ejection fraction and extent of left ventricular paradox were obtained in an attempt to identify a subgroup at increased risk of mortality during the ensuing months. The 16 patients who were alive after a 2 year follow-up period had a higher right ventricular ejection fraction and less extensive left ventricular dyskinesia. When a right ventricular ejection fraction of less than 35% was used as a discriminant, mortality was significantly greater among the 21 patients with a depressed right ventricular ejection fraction (71 versus 23%), a finding confirmed by a life table analysis. It appears that the multiple factors contributing to the reduction in right ventricular ejection fraction make it a useful index not only for assessing biventricular function, but also for predicting patient outcome

  12. Ejection fraction and outcomes in patients with atrial fibrillation and heart failure

    DEFF Research Database (Denmark)

    Banerjee, Amitava; Taillandier, Sophie; Olesen, Jonas Bjerring

    2012-01-01

    Heart failure (HF) increases the risk of stroke and thrombo-embolism (TE) in non-valvular atrial fibrillation (NVAF), and is incorporated in stroke risk stratification scores. We aimed to establish the role of ejection fraction (EF) in risk prediction in patients with NVAF and HF.......Heart failure (HF) increases the risk of stroke and thrombo-embolism (TE) in non-valvular atrial fibrillation (NVAF), and is incorporated in stroke risk stratification scores. We aimed to establish the role of ejection fraction (EF) in risk prediction in patients with NVAF and HF....

  13. New Classification for Heart Failure with Mildly Reduced Ejection Fraction; Greater clarity or more confusion?

    Directory of Open Access Journals (Sweden)

    Sunil Nadar

    2017-03-01

    Full Text Available The latest European Society of Cardiology (ESC guidelines for the diagnosis and management of heart failure include a new patient group for those with heart failure with mildly reduced ejection fraction (HFmrEF. By defining this group of patients as a separate entity, the ESC hope to encourage more research focusing on patients with HFmrEF. Previously, patients with this condition were caught between two classifications—heart failure with reduced ejection fraction and heart failure with preserved ejection fraction. Hopefully, the inclusion of new terminology will not increase confusion, but rather aid our understanding of heart failure, a complex clinical syndrome.

  14. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  15. The relationship between the parameters (Heart rate, Ejection fraction and BMI) and the maximum enhancement time of ascending aorta

    International Nuclear Information System (INIS)

    Jang, Young Ill; June, Woon Kwan; Dong, Kyeong Rae

    2007-01-01

    In this study, Bolus Tracking method was used to investigate the parameters affecting the time when contrast media is reached at 100 HU (T 100 ) and studied the relationship between parameters and T 100 because the time which is reached at aorta through antecubital vein after injecting contrast media is different from person to person. Using 64 MDCT, Cadiac CT, the data were obtained from 100 patients (male: 50, female: 50, age distribution: 21⁓81, average age: 57.5) during July and September, 2007 by injecting the contrast media at 4 ml∙sec -1 through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. Using Somatom Sensation Cardiac 64 Siemens, patients’ height and weight were measured to know their mean Heart rate and BMI. Ejection Fraction was measured using Argus Program at Wizard Workstation. Variances of each parameter were analyzed depending on T 100 ’s variation with multiple comparison and the correlation of Heart rate, Ejection Fraction and BMI were analyzed, as well. According to T 100 ’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T 100 ’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T 100 ’s variations were, but T 100 ’s variations caused by BMI were not affected. In the correlation between T 100 and parameters, Heart Rate (p⁄0.01) and Ejection Fraction (p⁄0.05) were significant, but BMI was not significant (p¤0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17 sec and less), Medium (18⁓21 sec), Slow (22 sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p⁄0.05), but BMI was not statistically significant. Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T 100 , Heart

  16. Gated cardiac imaging: manual calculations and observations of left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Hawkins, T.; Keavey, P.M.

    1984-01-01

    Using gamma camera imaging, the fixed region and moving region methods of calculating left ventricular ejection fraction were studied. Data were obtained from gated blood pool studies on 125 cardiac patients with myocardial infarcts of varying extent and location. Ejection fractions ranged from 10 to 76%. The left anterior oblique angulation for optimal visualisation of the ventricles showed considerable patient variation. The authors conclude that a fixed angulation cannot be recommended and that there is little to justify it. Where the septum is not seen distinctly during setting up, a larger rather than smaller angle is generally advised. (U.K.)

  17. Evaluation of left ventricular ejection fraction by first pass radionuclide cardioangiography

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, T; Imai, Y; Kagawa, M; Hayashi, M; Kozuka, T [National Cardiovascular Center, Suita, Osaka (Japan)

    1980-02-01

    The left ventricular ejection fraction can be assessed by recording the passage of peripherally administered radioactive bolus through the heart which is first pass method. In this study, the accuracy and validity of first pass method were examined in the patients with cardiac catheterization. After sup(99m)Tc-HSA as a bolus was injected intravenouslly, the time-activity curve was recorded with a scintillation camera and online minicomputer system. The ejection fraction was calculated by the average of three cardiac cycles which corresponded to the left ventricular volume changes during each cardiac cycles. The results correlated well with those obtained by biplane cineangiography in the twenty patients without arrythmias (r = 0.89) and moreover, this technique was applied to the fifteen patients with atrial fibrillation such as mitral valvular diseases, congestive cardiomyopathy, Good correlation of the ejection fraction (r = 0.84) was obtained. The findings, however, demonstrated that the time-activity curve must be generated from the region of interest which fits the left ventricular blood pool precisely and must be corrected for the contribution arizing from noncardiac background structures (two matrix method). In conclusion, this noninvasive method appears particularly useful for serial evaluation of the patients with cardiac dysfunctions and would be available for the routine examination of ventricular functions.

  18. Nuclear cardiac ejection fraction and cardiac index in abdominal aortic surgery

    International Nuclear Information System (INIS)

    Fiser, W.P.; Thompson, B.W.; Thompson, A.R.; Eason, C.; Read, R.C.

    1983-01-01

    Since atherosclerotic heart disease results in more than half of the perioperative deaths that follow abdominal aortic surgery, a prospective protocol was designed for preoperative evaluation and intraoperative hemodynamic monitoring. Twenty men who were prepared to undergo elective operation for aortoiliac occlusive disease (12 patients) and abdominal aortic aneurysm (eight patients) were evaluated with a cardiac scan and right heart catheterization. The night prior to operation, each patient received volume loading with crystalloid based upon ventricular performance curves. At the time of the operation, all patients were anesthetized with narcotics and nitrous oxide, and hemodynamic parameters were recorded throughout the operation. Aortic crossclamping resulted in a marked depression in CI in all patients. CI remained depressed after unclamping in the majority of patients. There were two perioperative deaths, both from myocardial infarction or failure. Both patients had ejection fractions less than 30% and initial CIs less than 2 L/M2, while the survivors' mean ejection fraction was 63% +/- 1 and their mean CI was 3.2 L/M2 +/- 0.6. The authors conclude that preoperative evaluation of ejection fraction can select those patients at a high risk of cardiac death from abdominal aortic operation. These patients should receive intensive preoperative monitoring with enhancement of ventricular performance

  19. Factor analysis of radionuclide ejection fraction response during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Yamamuro, Masashi

    1986-01-01

    In 204 patients with ischemic heart disease and 25 normal subjects who underwent exercise radionuclide ventriculography (RNV), multivariate analyses and other statistical methods were employed to study factors affecting changes in left ventricular ejection fraction (ΔEF). Twenty one variables were obtained from clinical diagnosis, cardiac catheterization, and RNV. Multivariate analyses showed that coronary score for the severity of coronary artery lesions was the most significant factor, followed by exercise duration, resting heart rate, the number of diseased vessels, and exercise heart rate. Statistically significant decrease in ΔEF was associated with regional wall motion abnormality, ECG changes, and chest pain. Lesions in the left main trunk and the proximal area of left anterior descending artery were greatly involved in the decrease of ΔEF. (Namekawa, K.)

  20. Invasive hemodynamic characterization of heart failure with preserved ejection fraction

    DEFF Research Database (Denmark)

    Andersen, Mads Jønsson; Borlaug, Barry A

    2014-01-01

    Recent hemodynamic studies have advanced our understanding of heart failure with preserved ejection fraction (HFpEF). Despite improved pathophysiologic insight, clinical trials have failed to identify an effective treatment for HFpEF. Invasive hemodynamic assessment can diagnose or exclude HFp...

  1. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  2. Murine Models of Heart Failure With Preserved Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Maria Valero-Muñoz, PhD

    2017-12-01

    Full Text Available Heart failure with preserved ejection fraction (HFpEF is characterized by signs and symptoms of heart failure in the presence of a normal left ventricular ejection fraction. Despite accounting for up to 50% of all clinical presentations of heart failure, the mechanisms implicated in HFpEF are poorly understood, thus precluding effective therapy. The pathophysiological heterogeneity in the HFpEF phenotype also contributes to this disease and likely to the absence of evidence-based therapies. Limited access to human samples and imperfect animal models that completely recapitulate the human HFpEF phenotype have impeded our understanding of the mechanistic underpinnings that exist in this disease. Aging and comorbidities such as atrial fibrillation, hypertension, diabetes and obesity, pulmonary hypertension, and renal dysfunction are highly associated with HFpEF, yet the relationship and contribution between them remains ill-defined. This review discusses some of the distinctive clinical features of HFpEF in association with these comorbidities and highlights the advantages and disadvantage of commonly used murine models used to study the HFpEF phenotype.

  3. International Geographic Variation in Event Rates in Trials of Heart Failure With Preserved and Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Kristensen, Søren L; Køber, Lars; Jhund, Pardeep S

    2015-01-01

    BACKGROUND: International geographic differences in outcomes may exist for clinical trials of heart failure and reduced ejection fraction (HF-REF), but there are few data for those with preserved ejection fraction (HF-PEF). METHODS AND RESULTS: We analyzed outcomes by international geographic reg...

  4. The survival of patients with heart failure with preserved or reduced left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Boesgaard, Søren

    2012-01-01

    A substantial proportion of patients with heart failure have preserved left ventricular ejection fraction (HF-PEF). Previous studies have reported mixed results whether survival is similar to those patients with heart failure and reduced EF (HF-REF).......A substantial proportion of patients with heart failure have preserved left ventricular ejection fraction (HF-PEF). Previous studies have reported mixed results whether survival is similar to those patients with heart failure and reduced EF (HF-REF)....

  5. Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds: application to the determination of right and left ejection fractions

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Collet, H.; Kotzki, P.-O.; Zanca, M.; Rossi, M.

    1998-01-01

    Tomographic multi-gated blood pool scintigraphy (TMUGA) is a widely available method which permits simultaneous assessment of right and left ventricular ejection fractions. However, the widespread clinical use of this technique is impeded by the lack of segmentation methods dedicated to an automatic analysis of ventricular activities. In this study we evaluated how a watershed algorithm succeeds in providing semi-automatic segmentation of ventricular activities in order to measure right and left ejection fractions by TMUGA. The left ejection fractions of 30 patients were evaluated both with TMUGA and with planar multi-gated blood pool scintigraphy (PMUGA). Likewise, the right ejection fractions of 25 patients were evaluated with first-pass scintigraphy (FP) and with TMUGA. The watershed algorithm was applied to the reconstructed slices in order to group together the voxels whose activity came from one specific cardiac cavity. First, the results of the watershed algorithm were compared with manual drawing around left and right ventricles. Left ejection fractions evaluated by TMUGA with the watershed procedure were not significantly different (p=0.30) from manual outlines whereas a small but significant difference was found for right ejection fractions (p=0.004). Then right and left ejection fractions evaluated by TMUGA (with the semi-automatic segmentation procedure) were compared with the results obtained by FP or PMUGA. Left ventricular ejection fractions evaluated by TMUGA showed an excellent correlation with those evaluated by PMUGA (r=0.93; SEE=5.93%; slope=0.99; intercept = 4.17%). The measurements of these ejection fractions were significantly higher with TMUGA than with PMUGA (P<0.01). The interoperator variability for the measurement of left ejection fractions by TMUGA was 4.6%. Right ventricular ejection fractions evaluated by TMUGA showed a good correlation with those evaluated by FP (r = 0.81; SEE = 6.68%; slope = 1.00; intercept = 0.85%) and were not

  6. Non-invasive assessment of right ventricular function at rest and on exercise in obstructive airways disease

    International Nuclear Information System (INIS)

    Tweddel, A.; Martin, W.; McGhie, I.; Neilly, B.; Stevenson, R.; Hutton, I.

    1985-01-01

    Non-invasive assessment of right ventricular function is of clinical interest in the patient with obstructive airways disease. Gated Xenon 133 scanning allows right ventricular function to be evaluated in isolation from the left ventricle, and with rapid clearance from the lungs, scans may be repeated within 5 minutes. 400mBq of Xenon 133 were injected intravenously over 20 seconds and images were obtained using a mobile gamma camera. Maximal symptom limited exercise was performed on a supine bicycle ergometer. The normal range for right ventricular ejection fraction (RVEF) was obtained from 10 volunteers - 40-55% at rest rising by 5-15% during exercise. In 10 patients with acute obstructive airways disease, all had reduced RVEF 21 +- 3%. In chronic obstructive airways disease, if resting RVEF was greater than 30%, ejection fraction increased on exercise. If resting ejection fraction was abnormal than RVEF was reduced or unchanged on exercise (mean 15 +- 9%), and this was associated with dilatation of both the right ventricle and atrium. In conclusion, gated Xenon 133 offers a simple method of assessing right ventricular function at rest and on exercise in the patient with obstructive airways disease

  7. Noninvasive Assessment of Preload Reserve Enhances Risk Stratification of Patients With Heart Failure With Reduced Ejection Fraction.

    Science.gov (United States)

    Matsumoto, Kensuke; Onishi, Akira; Yamada, Hirotsugu; Kusunose, Kenya; Suto, Makiko; Hatani, Yutaka; Matsuzoe, Hiroki; Tatsumi, Kazuhiro; Tanaka, Hidekazu; Hirata, Ken-Ichi

    2018-05-01

    The leg-positive pressure maneuver can safely and noninvasively apply preload stress without increase in total body fluid volume. The purpose of this study was to determine whether preload stress could be useful for risk stratification of patients with heart failure with reduced ejection fraction. For this study, 120 consecutive patients with heart failure with reduced ejection fraction were prospectively recruited. The stroke work index was estimated as product of stroke volume index and mean blood pressure, and the E/e' ratio was calculated to estimate ventricular filling pressure. The echocardiographic parameters were obtained both at rest and during leg-positive pressure stress. During the median follow-up period of 20 months, 30 patients developed adverse cardiovascular events. During preload stress, stroke work index increased significantly (from 3280±1371 to 3857±1581 mm Hg·mL/m 2 ; P <0.001) along with minimal changes in ventricular filling pressure (E/e', from 16±10 to 17±9; P <0.05) in patients without cardiovascular events. However, patients with cardiovascular events showed impairment of Frank-Starling mechanism (stroke work index, from 2863±969 to 2903±1084 mm Hg·mL/m 2 ; P =0.70) and a serious increase in E/e' ratio (from 19±11 to 25±14; P <0.001). Both the patients without contractile reserve and those without diastolic reserve exhibited worse event-free survival than the others ( P <0.001). In a Cox proportional-hazards analysis, the changes in stroke work index (hazard ratio: 0.44 per 500 mm Hg·mL/m 2 increase; P =0.001) and in E/e' (hazard ratio: 2.58 per 5-U increase; P <0.001) were predictors of cardiovascular events. Contractile reserve and diastolic reserve during leg-positive pressure stress are important determinants of cardiovascular outcomes for patients with heart failure with reduced ejection fraction. © 2018 American Heart Association, Inc.

  8. Heart Failure: The Dilemma of the 40-50% Ejection Fraction Range

    Directory of Open Access Journals (Sweden)

    Michael Henein

    2017-01-01

    Full Text Available The common pathophysiology contributing to fluid retention and dyspnoea in heart failure is a non-compliant and stiff myocardium with raised left ventricular end-diastolic pressure. With the rapid development of newer imaging technologies, particularly echocardiography, our understanding of the syndrome of heart failure has significantly changed. The most important imaging sign in the early eighties was reduced ejection fraction (HFrEF, with low values being used as an explanation for the development of signs and symptoms. In the early 2000s, similar Doppler echocardiographic signs became frequently recognised in patients with heart failure symptoms and signs who proved to have a relatively maintained ejection fraction (EF of >40%, hence the description of the syndrome of “diastolic heart failure”. This was later rephrased as heart failure with normal ejection fraction (HFnEF and more recently as heart failure with preserved ejection fraction (HFpEF. Since then, HFpEF has attracted the interest of many cardiologists and scientists worldwide, searching for specific features and treatment options for the syndrome. As for the features, two important findings have now been established, the first showed that LV systolic function mainly at the subendocardial level was abnormal in HFpEF, particularly manifesting during stress/exercise when the increase in heart rate was not associated with a commensurate increase in stroke volume and a second observation of a significant impairment of left atrial function (i.e. myocardial strain and emptying fraction associated with increased left atrial pressures and the potential development of atrial arrhythmia in HFpEF. Such atrial abnormalities have been shown to be commonly associated with cavity enlargement and poor compliance. The latter observation has similarly been reported in patients with reduced EF. Despite the above similarities in cardiac physiology between HFpEF and HFrEF, treatments of the two

  9. Identification of ultrasound-contrast-agent dilution systems for ejection fraction measurements

    NARCIS (Netherlands)

    Mischi, M.; Jansen, A.H.M.; Kalker, A.A.C.M.; Korsten, H.H.M.

    2005-01-01

    Left ventricular ejection fraction is an important cardiac-efficiency measure. Standard estimations are based on geometric analysis and modeling; they require time and experienced cardiologists. Alternative methods make use of indicator dilutions, but they are invasive due to the need for

  10. Incremental first pass technique to measure left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Kocak, R.; Gulliford, P.; Hoggard, C.; Critchley, M.

    1980-01-01

    An incremental first pass technique was devised to assess the acute effects of any drug on left ventricular ejection fraction (LVEF) with or without a physiological stress. In particular, the effects of the vasodilater isosorbide dinitrate on LVEF before and after exercise were studied in 11 patients who had suffered cardiac failure. This was achieved by recording the passage of sup(99m)Tc pertechnetate through the heart at each stage of the study using a gamma camera computer system. Consistent values for four consecutive first pass values without exercise or drug in normal subjects illustrated the reproducibility of the technique. There was no significant difference between LVEF values obtained at rest and exercise before or after oral isosorbide dinitrate with the exception of one patient with gross mitral regurgitation. The advantages of the incremental first pass technique are that the patient need not be in sinus rhythm, the effects of physiological intervention may be studied and tests may also be repeated at various intervals during long term follow-up of patients. A disadvantage of the method is the limitation in the number of sequential measurements which can be carried out due to the amount of radioactivity injected. (U.K.)

  11. The relationship between mitral regurgitation and ejection fraction as predictors for the prognosis of patients with heart failure

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Torp-Pedersen, Christian; Hassager, Christian

    2011-01-01

    To study whether there is interaction between mitral regurgitation (MR) and left ventricular ejection fraction (LVEF) in the mortality risk of heart failure (HF) patients.......To study whether there is interaction between mitral regurgitation (MR) and left ventricular ejection fraction (LVEF) in the mortality risk of heart failure (HF) patients....

  12. Thallium-201 myocardial scintigraphy and left ventricular function at rest in patients with rest angina pectoris

    International Nuclear Information System (INIS)

    Hakki, A.H.; Iskandrian, A.S.; Kane, S.A.; Amenta, A.

    1984-01-01

    The purpose of this study was to examine the rest thallium-201 perfusion pattern during angina-free periods in 40 patients with rest angina pectoris secondary to coronary artery disease (greater than or equal to 70% diameter narrowing). Seventeen patients had previous Q wave myocardial infarction. The perfusion defects were considered fixed or reversible, depending on the absence or presence of redistribution in the 4-hour delayed images. There were 40 perfusion defects (26 fixed and 14 reversible) in 27 patients whereas 13 patients had normal scans. Reversible perfusion defects were present in 10 patients (25%). Of the 26 fixed perfusion defects, 17 did not have corresponding Q waves. Occluded vessels (63%) had more perfusion defects than vessels with subtotal occlusion (30%) (p less than 0.01). The perfusion defect size was larger in patients with lower ejection fraction than in patients with higher ejection fraction. We conclude: (1) perfusion defects are common in patients with rest angina and are reversible in 25% of patients indicating reduced regional coronary blood flow; (2) the degree of stenosis affects the presence of perfusion defect; (3) fixed defects may be present without corresponding Q waves; and (4) global left ventricular function is related to the size of perfusion defects

  13. Epidemiology of heart failure with preserved ejection fraction

    DEFF Research Database (Denmark)

    Andersson, Charlotte; Vasan, Ramachandran S

    2014-01-01

    Heart failure with preserved ejection fraction (HFPEF) is a common condition, and the prevalence is projected to increase further. Studies differ in the reported incidence and mortality associated with this condition, although there is agreement that between a third and one-half of all patients...... with heart failure have HFPEF. Although several consensus statements and guidelines have been published, some recent randomized clinical trials have reported low mortality, raising doubts about whether all patients diagnosed with HFPEF have HFPEF or whether the condition is heterogeneous in its cause...

  14. Clinical Utility of Exercise Training in Heart Failure with Reduced and Preserved Ejection Fraction

    Science.gov (United States)

    Asrar Ul Haq, Muhammad; Goh, Cheng Yee; Levinger, Itamar; Wong, Chiew; Hare, David L

    2015-01-01

    Reduced exercise tolerance is an independent predictor of hospital readmission and mortality in patients with heart failure (HF). Exercise training for HF patients is well established as an adjunct therapy, and there is sufficient evidence to support the favorable role of exercise training programs for HF patients over and above the optimal medical therapy. Some of the documented benefits include improved functional capacity, quality of life (QoL), fatigue, and dyspnea. Major trials to assess exercise training in HF have, however, focused on heart failure with reduced ejection fraction (HFREF). At least half of the patients presenting with HF have heart failure with preserved ejection fraction (HFPEF) and experience similar symptoms of exercise intolerance, dyspnea, and early fatigue, and similar mortality risk and rehospitalization rates. The role of exercise training in the management of HFPEF remains less clear. This article provides a brief overview of pathophysiology of reduced exercise tolerance in HFREF and heart failure with preserved ejection fraction (HFPEF), and summarizes the evidence and mechanisms by which exercise training can improve symptoms and HF. Clinical and practical aspects of exercise training prescription are also discussed. PMID:25698883

  15. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  16. Factors related to outcome in heart failure with a preserved (or normal) left ventricular ejection fraction.

    Science.gov (United States)

    Sanderson, John E

    2016-07-01

    Heart failure with a preserved ejection faction (HFpEF) is a growing and expensive cause of heart failure (HF) affecting particularly the elderly. It differs in substantial ways in addition to the normal left ventricular ejection fraction, from the more easily recognized form of heart failure with a reduced ejection fraction (HFrEF or 'systolic heart failure') and unlike HFrEF there have been little advances in treatment. In part, this relates to the complexity of the pathophysiology and identifying the correct targets. In HFpEF, there appears to be widespread stiffening of the vasculature and the myocardium affecting ventricular function (both systolic and diastolic), impeding ventricular suction, and thus early diastolic filling leading to breathlessness on exertion and later atrial failure and fibrillation. Left ventricular ejection fraction tends to gradually decline and some evolve into HFrEF. Most patients also have a mixture of several co-morbidities including hypertension, diabetes, obesity, poor renal function, lack of fitness, and often poor social conditions. Therefore, many factors may influence outcome in an individual patient. In this review, the epidemiology, possible causation, pathophysiology, the influence of co-morbidities and some of the many potential predictors of outcome will be considered.

  17. Evaluation by means of ECG-gated cardiac blood pool scintigraphy of global and regional left ventricular function at rest and during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Sauer, E.; Sebening, H.; Lutilsky, L.; Dressler, H.; Hoer, G.; Pabst, H.W.; Bloemer, H.; Technische Univ. Muenchen

    1978-01-01

    ECG-gated cardiac blood pool scintigraphy permits a non-invasive determination of the end-diastolic and end-systolic ventricular volumens and of the ejection fraction as well as a qualitative description of regional ventricular wall motion at rest and during exercise. In 6 healthy persons a significant increase of the ejection fraction from 66 +- 7% at rest to 78 +- 3% during exercise (p [de

  18. Evaluation of left ventricular ejection fraction using quantitative gated SPECT (QGS)

    International Nuclear Information System (INIS)

    Musa, M. A. A.

    2010-07-01

    Electrocardiographic ally gated myocardial perfusion SPECT (G SPECT) is a state-of the art technique for the combined evaluation of myocardial perfusion and left ventricular function within a single study. It is currently one of the most commonly performed cardiology procedures in a nuclear medicine department. Automation of the image processing and quantification has made this techniques highly reproducible, practical and user friendly in the clinical setting . In patients with coronary artery disease, gating enhances the diagnostic and prognostic capability of myocardial perfusion imaging provides incremental information over the the perfusion data, and has shown potentials for myocardial viability assessment and sequential follow-up after therapy. Evaluation of the left ventricular (L V) function is important in clinical cardiology. Quantifying the degree and extent of the L V functional abnormalities permits a systematic assessment of the disease process on the myocardial performance. The aim of this thesis is to evaluate left ventricular ejection fraction (LVEF) in patients with no evidence of ischemic response during the stress test. This investigation was carried out in view of the few reports concerning the findings ventricular function with gated SPECT in these situations in the normal population, which is relevant when considering the possibility of myocardial stunning. Method: We prospectively studied 30 selected patients, in difference age and gender. A one-day protocol was used, with injection 555 MBq - 1.11 MBq (15 - 30 mCi) of 99 mTc-M1 B1 at stress and rest. Gated perfusion SPECT was acquired 30 to 60 minutes after radiotracer injection in both condition and processed using QGSPECT software. Difference between stress and rest LVEF was calculated. Result and conclusion: rest LVEF was higher in the stress (exercise) group, A trend line was done in both groups and r-value was (0.9) and p=0.04 in acceptance value. Standard deviation of LVEF also was

  19. Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector

    International Nuclear Information System (INIS)

    Wagner, H.N. Jr.; Rigo, P.; Baxter, R.H.; Alderson, P.O.; Douglass, K.H.; Housholder, D.F.

    1979-01-01

    A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operting modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64% (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7

  20. Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector.

    Science.gov (United States)

    Wagner, H N; Rigo, P; Baxter, R H; Alderson, P O; Douglass, K H; Housholder, D F

    1979-05-01

    A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operating modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64 percent (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7.

  1. Evaluation of training nurses to perform semi-automated three-dimensional left ventricular ejection fraction using a customised workstation-based training protocol.

    Science.gov (United States)

    Guppy-Coles, Kristyan B; Prasad, Sandhir B; Smith, Kym C; Hillier, Samuel; Lo, Ada; Atherton, John J

    2015-06-01

    We aimed to determine the feasibility of training cardiac nurses to evaluate left ventricular function utilising a semi-automated, workstation-based protocol on three dimensional echocardiography images. Assessment of left ventricular function by nurses is an attractive concept. Recent developments in three dimensional echocardiography coupled with border detection assistance have reduced inter- and intra-observer variability and analysis time. This could allow abbreviated training of nurses to assess cardiac function. A comparative, diagnostic accuracy study evaluating left ventricular ejection fraction assessment utilising a semi-automated, workstation-based protocol performed by echocardiography-naïve nurses on previously acquired three dimensional echocardiography images. Nine cardiac nurses underwent two brief lectures about cardiac anatomy, physiology and three dimensional left ventricular ejection fraction assessment, before a hands-on demonstration in 20 cases. We then selected 50 cases from our three dimensional echocardiography library based on optimal image quality with a broad range of left ventricular ejection fractions, which was quantified by two experienced sonographers and the average used as the comparator for the nurses. Nurses independently measured three dimensional left ventricular ejection fraction using the Auto lvq package with semi-automated border detection. The left ventricular ejection fraction range was 25-72% (70% with a left ventricular ejection fraction nurses showed excellent agreement with the sonographers. Minimal intra-observer variability was noted on both short-term (same day) and long-term (>2 weeks later) retest. It is feasible to train nurses to measure left ventricular ejection fraction utilising a semi-automated, workstation-based protocol on previously acquired three dimensional echocardiography images. Further study is needed to determine the feasibility of training nurses to acquire three dimensional echocardiography

  2. Clinical utility of semi-automated estimation of ejection fraction at the point-of-care

    DEFF Research Database (Denmark)

    Frederiksen, Christian Alcaraz; Juhl-Olsen, Peter; Hermansen, Johan Fridolf

    2015-01-01

    ultrasonography of the heart at the bedside performed by a novice examiner. Three assessments of ejection fraction were made: 1) Expert eyeballing by a single specialist in cardiology and expert in echocardiography; 2) Manual planimetry by an experienced examiner; 3) AutoEF by a novice examiner with limited...... experience in echocardiography. RESULTS: Expert eyeballing of ejection fraction was performed in 100% of cases. Manual planimetry was possible in 89% of cases and AutoEF was possible in 83% of cases. The correlation between expert eyeballing and AutoEF was r=0.82, p ... and for AutoEF it was r=0.82, p eyeballing and manual planimetry it was r=0.80, p

  3. Association between Hypotension, Low Ejection Fraction and Cognitive Performance in Cardiac Patients

    Directory of Open Access Journals (Sweden)

    Rebecca F. Gottesman

    2010-01-01

    Full Text Available Background and Purpose: Impaired cardiac function can adversely affect the brain via decreased perfusion. The purpose of this study was to determine if cardiac ejection fraction (EF is associated with cognitive performance, and whether this is modified by low blood pressure.

  4. Mechanisms for decreased exercise capacity after bed rest in normal middle-aged men

    International Nuclear Information System (INIS)

    Hung, J.; Goldwater, D.; Convertino, V.A.; McKillop, J.H.; Goris, M.L.; DeBusk, R.F.

    1983-01-01

    The mechanisms responsible for the decrease in exercise capacity after bed rest were assessed in 12 apparently healthy men aged 50 +/- 4 years who underwent equilibrium gated blood pool scintigraphy during supine and upright multistage bicycle ergometry before and after 10 days of bed rest. After bed rest, echocardiographically measured supine resting left ventricular end-diastolic volume decreased by 16% (p less than 0.05). Peak oxygen uptake during supine effort after bed rest was diminished by 6% (p . not significant [NS]), whereas peak oxygen uptake during upright effort declined by 15% (p less than 0.05). After bed rest, increases in heart rate were also greater during exercise in the upright than in the supine position (p less than 0.05). Values of left ventricular ejection fraction increased normally during both supine and upright effort after bed rest and were higher than corresponding values before bed rest (p less than 0.05). After bed rest, increased left ventricular ejection fraction and heart rate largely compensated for the reduced cardiac volume during supine effort, but these mechanisms were insufficient to maintain oxygen transport capacity at levels during upright effort before bed rest. These results indicate that orthostatically induced cardiac underfilling, not physical deconditioning or left ventricular dysfunction, is the major cause of reduced effort tolerance after 10 days of bed rest in normal middle-aged men

  5. High-Intensity Interval Training in Patients with Heart Failure with Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Ellingsen, Øyvind; Halle, Martin; Conraads, Viviane

    2017-01-01

    Background: Small studies have suggested that high-intensity interval training (HIIT) is superior to moderate continuous training (MCT) in reversing cardiac remodeling and increasing aerobic capacity in patients with heart failure with reduced ejection fraction. The present multicenter trial...... compared 12 weeks of supervised interventions of HIIT, MCT, or a recommendation of regular exercise (RRE). Methods: Two hundred sixty-one patients with left ventricular ejection fraction ≤35% and New York Heart Association class II to III were randomly assigned to HIIT at 90% to 95% of maximal heart rate...... ventricular end-diastolic diameter from baseline to 12 weeks. Results: Groups did not differ in age (median, 60 years), sex (19% women), ischemic pathogenesis (59%), or medication. Change in left ventricular end-diastolic diameter from baseline to 12 weeks was not different between HIIT and MCT (P=0.45); left...

  6. Risk Related to Pre–Diabetes Mellitus and Diabetes Mellitus in Heart Failure With Reduced Ejection Fraction

    Science.gov (United States)

    Kristensen, Søren L.; Preiss, David; Jhund, Pardeep S.; Squire, Iain; Cardoso, José Silva; Merkely, Bela; Martinez, Felipe; Starling, Randall C.; Desai, Akshay S.; Lefkowitz, Martin P.; Rizkala, Adel R.; Rouleau, Jean L.; Shi, Victor C.; Solomon, Scott D.; Swedberg, Karl; Zile, Michael R.; Packer, Milton

    2016-01-01

    Background— The prevalence of pre–diabetes mellitus and its consequences in patients with heart failure and reduced ejection fraction are not known. We investigated these in the Prospective Comparison of ARNI With ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure (PARADIGM-HF) trial. Methods and Results— We examined clinical outcomes in 8399 patients with heart failure and reduced ejection fraction according to history of diabetes mellitus and glycemic status (baseline hemoglobin A1c [HbA1c]: 6.5%) and known diabetes mellitus compared with those with HbA1csacubitril/valsartan) compared with enalapril was consistent across the range of HbA1c in the trial. Conclusions— In patients with heart failure and reduced ejection fraction, dysglycemia is common and pre–diabetes mellitus is associated with a higher risk of adverse cardiovascular outcomes (compared with patients with no diabetes mellitus and HbA1c <6.0%). LCZ696 was beneficial compared with enalapril, irrespective of glycemic status. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT01035255. PMID:26754626

  7. Effects of projection and background correction method upon calculation of right ventricular ejection fraction using first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Caplin, J.L.; Flatman, W.D.; Dymond, D.S.

    1985-01-01

    There is no consensus as to the best projection or correction method for first-pass radionuclide studies of the right ventricle. We assessed the effects of two commonly used projections, 30 degrees right anterior oblique and anterior-posterior, on the calculation of right ventricular ejection fraction. In addition two background correction methods, planar background correction to account for scatter, and right atrial correction to account for right atrio-ventricular overlap were assessed. Two first-pass radionuclide angiograms were performed in 19 subjects, one in each projection, using gold-195m (half-life 30.5 seconds), and each study was analysed using the two methods of correction. Right ventricular ejection fraction was highest using the right anterior oblique projection with right atrial correction 35.6 +/- 12.5% (mean +/- SD), and lowest when using the anterior posterior projection with planar background correction 26.2 +/- 11% (p less than 0.001). The study design allowed assessment of the effects of correction method and projection independently. Correction method appeared to have relatively little effect on right ventricular ejection fraction. Using right atrial correction correlation coefficient (r) between projections was 0.92, and for planar background correction r = 0.76, both p less than 0.001. However, right ventricular ejection fraction was far more dependent upon projection. When the anterior-posterior projection was used calculated right ventricular ejection fraction was much more dependent on correction method (r = 0.65, p = not significant), than using the right anterior oblique projection (r = 0.85, p less than 0.001)

  8. Measurement of left ventricular ejection fraction using gated 99mTc-sestamibi myocardial planar images: Comparison to contrast ventriculography

    International Nuclear Information System (INIS)

    Parker, D.A.; Lloret, R.L.; Barilla, F.; Douthat, L.; Gheorghiade, M.

    1991-01-01

    Using the new myocardial perfusion agent 99mTc-sestamibi and multigated acquisition on a nuclear medicine gamma camera, the left ventricular ejection fraction (LVEF) was derived in 13 patients with coronary artery disease (CAD). Cross-sectional activity profiles were used to measure the left ventricle from end-diastolic and end-systolic images. Several different geometric methods were then utilized to derive ejection fractions from the nuclear data. Comparison of the resultant ejection fractions to those obtained from contrast ventriculography showed significant correlation for all geometric methods (P less than 0.01, Sy X x = 6.2 to 9.6). The authors conclude that in patients with CAD one or more of these simple geometric methods can provide a useful estimate of the LVEF when performing 99mTc-sestamibi multigated myocardial perfusion imaging

  9. Exercise physiology in heart failure and preserved ejection fraction.

    Science.gov (United States)

    Haykowsky, Mark J; Kitzman, Dalane W

    2014-07-01

    Recent advances in the pathophysiology of exercise intolerance in patients with heart failure with preserved ejection fraction (HFPEF) suggest that noncardiac peripheral factors contribute to the reduced peak V(o2) (peak exercise oxygen uptake) and to its improvement after endurance exercise training. A greater understanding of the peripheral skeletal muscle vascular adaptations that occur with physical conditioning may allow for tailored exercise rehabilitation programs. The identification of specific mechanisms that improve whole body and peripheral skeletal muscle oxygen uptake could establish potential therapeutic targets for medical therapies and a means to follow therapeutic response. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Submaximal oxygen uptake kinetics, functional mobility, and physical activity in older adults with heart failure and reduced ejection fraction

    OpenAIRE

    Hummel, Scott L; Herald, John; Alpert, Craig; Gretebeck, Kimberlee A; Champoux, Wendy S; Dengel, Donald R; Vaitkevicius, Peter V; Alexander, Neil B

    2016-01-01

    Background Submaximal oxygen uptake measures are more feasible and may better predict clinical cardiac outcomes than maximal tests in older adults with heart failure (HF). We examined relationships between maximal oxygen uptake, submaximal oxygen kinetics, functional mobility, and physical activity in older adults with HF and reduced ejection fraction. Methods Older adults with HF and reduced ejection fraction (n = 25, age 75 ? 7 years) were compared to 25 healthy age- and gender-matched cont...

  11. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  12. Usefulness of the troponin-ejection fraction product to differentiate stress cardiomyopathy from ST-segment elevation myocardial infarction.

    Science.gov (United States)

    Nascimento, Francisco O; Yang, Solomon; Larrauri-Reyes, Maiteder; Pineda, Andres M; Cornielle, Vertilio; Santana, Orlando; Heimowitz, Todd B; Stone, Gregg W; Beohar, Nirat

    2014-02-01

    The presentation of stress cardiomyopathy (SC) with nonobstructive coronary artery disease mimics that of ST-segment elevation myocardial infarction (STEMI) due to coronary occlusion. No single parameter has been successful in differentiating the 2 entities. We thus sought to develop a noninvasive clinical tool to discriminate between these 2 conditions. We retrospectively reviewed 59 consecutive cases of SC at our institution from July 2005 through June 2011 and compared those with 60 consecutives cases of angiographically confirmed STEMI treated with primary percutaneous coronary intervention in the same period. All patients underwent acute echocardiography, and the peak troponin I level was determined. The troponin-ejection fraction product (TEFP) was derived by multiplying the peak troponin I level and the echocardiographically derived left ventricular ejection fraction. Comparing the SC and STEMI groups, the mean left ventricular ejection fraction at the time of presentation was 30 ± 9% versus 44 ± 11%, respectively (p statistic 0.91 ± 0.02, p <0.001). In conclusion, for patients not undergoing emergent angiography, the TEFP may be used with high accuracy to differentiate SC with nonobstructive coronary artery disease from true STEMI due to coronary occlusion. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Structural and Functional Phenotyping of the Failing Heart: Is the Left Ventricular Ejection Fraction Obsolete?

    Science.gov (United States)

    Bristow, Michael R; Kao, David P; Breathett, Khadijah K; Altman, Natasha L; Gorcsan, John; Gill, Edward A; Lowes, Brian D; Gilbert, Edward M; Quaife, Robert A; Mann, Douglas L

    2017-11-01

    Diagnosis, prognosis, treatment, and development of new therapies for diseases or syndromes depend on a reliable means of identifying phenotypes associated with distinct predictive probabilities for these various objectives. Left ventricular ejection fraction (LVEF) provides the current basis for combined functional and structural phenotyping in heart failure by classifying patients as those with heart failure with reduced ejection fraction (HFrEF) and those with heart failure with preserved ejection fraction (HFpEF). Recently the utility of LVEF as the major phenotypic determinant of heart failure has been challenged based on its load dependency and measurement variability. We review the history of the development and adoption of LVEF as a critical measurement of LV function and structure and demonstrate that, in chronic heart failure, load dependency is not an important practical issue, and we provide hemodynamic and molecular biomarker evidence that LVEF is superior or equal to more unwieldy methods of identifying phenotypes of ventricular remodeling. We conclude that, because it reliably measures both left ventricular function and structure, LVEF remains the best current method of assessing pathologic remodeling in heart failure in both individual clinical and multicenter group settings. Because of the present and future importance of left ventricular phenotyping in heart failure, LVEF should be measured by using the most accurate technology and methodologic refinements available, and improved characterization methods should continue to be sought. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Benefits and Harms of Sacubitril in Adults With Heart Failure and Reduced Left Ventricular Ejection Fraction.

    Science.gov (United States)

    Aronow, Wilbert S; Shamliyan, Tatyana A

    2017-10-01

    The quality of evidence regarding patient-centered outcomes in adults with heart failure (HF) after sacubitril combined with valsartan has not been systematically appraised. We searched 4 databases in February 2017 and graded the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation working group approach. We reviewed 1 meta-analysis and multiple publications of 2 randomized controlled trials (RCT) and 1 unpublished RCT. In adults with HF and reduced ejection fraction, low-quality evidence from 1 RCT of 8,432 patients suggests that sacubitril combined with valsartan reduces all-cause (number needed to treat [NNT] to prevent 1 event [NNTp] = 35) and cardiovascular mortality (NNTp = 32), hospitalization (NNTp = 11), emergency visits (NNTp = 69), and serious adverse effects, leading to treatment discontinuation (NNTp = 63) and improves quality of life when compared with enalapril. In adults with HF and preserved ejection fraction, very low-quality evidence from 1 RCT of 301 patients suggests that there are no differences in mortality, morbidity, or adverse effects between sacubitril combined with valsartan and valsartan alone. In conclusion, in adults with HF and reduced ejection fraction, to reduce cardiovascular mortality and hospitalizations and improve quality of life, clinicians may recommend sacubitril combined with valsartan over angiotensin-converting enzyme inhibitors. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Value of Age, Creatinine, and Ejection Fraction (ACEF Score) in Assessing Risk in Patients Undergoing Percutaneous Coronary Interventions in the 'All-Comers' LEADERS Trial

    NARCIS (Netherlands)

    Wykrzykowska, Joanna J.; Garg, Scot; Onuma, Yoshinobu; de Vries, Ton; Goedhart, Dick; Morel, Marie-Angele; van Es, Gerrit-Anne; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Corti, Roberto; Eberli, Franz; Wijns, William; Morice, Marie-Claude; Di Mario, Carlo; van Geuns, Robert Jan; Juni, Peter; Windecker, Stephan; Serruys, Patrick W.

    2011-01-01

    Background-The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine >2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in

  16. Response of right ventricular ejection fraction to exercise stress in coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1985-01-01

    The right ventricular (RV) response to exercise was assessed in 28 patients with coronary artery disease (CAD) and 9 normal subjects. The relationship between RV reserve, exercise left ventricular (LV) reserve and the presence of proximal right coronary artery (RCA) stenosis were evaluated. RV and LV ejection fraction (EF) were determined by multiple-gated equilibrium blood pool imaging with sup(99m)Tc in the modified left anterior oblique position. Graded supine exercise stress blood pool imaging was performed at the same position by using bicycle ergometer. For calculation of RVEF, variable ROIs were used. In normal subjects, both RVEF and LVEF increased significantly during exercise (%ΔRVEF 18.9+-5.9%, %ΔLVEF 16.3%+-4.7%). In CAD groups with and without RCA stenosis, LVEF and RVEF showed decrease or no change during exercise. Although magnitude of change in LVEF from rest to exercise (%ΔLVEF) was not significantly different in both CAD groups (4.1+-9.0% in cases with RCA disease and 6.2+-14.6% in cases without RCA disease), %ΔRVEF was different significantly (16.0+-14.3% in cases with RCA disease and 1.4+-14.1% in cases without RCA disease, p<0.05). In patients with RCA disease, 3 patients (25%) showed depression in RVEF with exercise regardless of the increase in LVEF. However, none of the patients without RCA disease showed depression in RVEF with the increment in LVEF during exercise. These findings suggested that proximal RCA stenosis is one major determinant of exercise RVEF response. But in 9 of 16 patients without RCA disease (56%) both RVEF and LVEF decreased during exercise. Besides, in patients without RCA disease there was a significant linear relationship between the direction and magnitude of change from rest to exercise of LVEF and RVEF (r=0.69). (J.P.N.)

  17. Clinical and Echocardiographic Characteristics and Cardiovascular Outcomes According to Diabetes Status in Patients With Heart Failure and Preserved Ejection Fraction

    DEFF Research Database (Denmark)

    Kristensen, Søren L; Mogensen, Ulrik M; Jhund, Pardeep S

    2017-01-01

    in Heart Failure With Preserved Ejection Fraction) according to history of diabetes mellitus. Cox regression models were used to estimate hazard ratios for cardiovascular outcomes adjusted for known predictors, including age, sex, natriuretic peptides, and comorbidity. Echocardiographic data were available...... versus 29 kg/m2), worse Minnesota Living With Heart Failure score (48 versus 40), higher median N-terminal pro-B-type natriuretic peptide concentration (403 versus 320 pg/mL; all Pdifference in left ventricular ejection fraction. Patients with diabetes...

  18. Biomarker Profiles of Acute Heart Failure Patients With a Mid-Range Ejection Fraction.

    Science.gov (United States)

    Tromp, Jasper; Khan, Mohsin A F; Mentz, Robert J; O'Connor, Christopher M; Metra, Marco; Dittrich, Howard C; Ponikowski, Piotr; Teerlink, John R; Cotter, Gad; Davison, Beth; Cleland, John G F; Givertz, Michael M; Bloomfield, Daniel M; Van Veldhuisen, Dirk J; Hillege, Hans L; Voors, Adriaan A; van der Meer, Peter

    2017-07-01

    In this study, the authors used biomarker profiles to characterize differences between patients with acute heart failure with a midrange ejection fraction (HFmrEF) and compare them with patients with a reduced (heart failure with a reduced ejection fraction [HFrEF]) and preserved (heart failure with a preserved ejection fraction [HFpEF]) ejection fraction. Limited data are available on biomarker profiles in acute HFmrEF. A panel of 37 biomarkers from different pathophysiological domains (e.g., myocardial stretch, inflammation, angiogenesis, oxidative stress, hematopoiesis) were measured at admission and after 24 h in 843 acute heart failure patients from the PROTECT trial. HFpEF was defined as left ventricular ejection fraction (LVEF) of ≥50% (n = 108), HFrEF as LVEF of <40% (n = 607), and HFmrEF as LVEF of 40% to 49% (n = 128). Hemoglobin and brain natriuretic peptide levels (300 pg/ml [HFpEF]; 397 pg/ml [HFmrEF]; 521 pg/ml [HFrEF]; p trend  <0.001) showed an upward trend with decreasing LVEF. Network analysis showed that in HFrEF interactions between biomarkers were mostly related to cardiac stretch, whereas in HFpEF, biomarker interactions were mostly related to inflammation. In HFmrEF, biomarker interactions were both related to inflammation and cardiac stretch. In HFpEF and HFmrEF (but not in HFrEF), remodeling markers at admission and changes in levels of inflammatory markers across the first 24 h were predictive for all-cause mortality and rehospitalization at 60 days (p interaction  <0.05). Biomarker profiles in patients with acute HFrEF were mainly related to cardiac stretch and in HFpEF related to inflammation. Patients with HFmrEF showed an intermediate biomarker profile with biomarker interactions between both cardiac stretch and inflammation markers. (PROTECT-1: A Study of the Selective A1 Adenosine Receptor Antagonist KW-3902 for Patients Hospitalized With Acute HF and Volume Overload to Assess Treatment Effect on Congestion and Renal

  19. Inter-observer variation in estimates by nuclear angiography of left ventricular ejection fraction and ejection rate

    International Nuclear Information System (INIS)

    Young, K.C.; Railton, R.

    1980-01-01

    The recent decline in the cost of computing has led to the introduction of data processing of gamma-camera images in many medical centres, allowing the development and widespread use of radionuclide techniques for assessing left ventricular performance. Methods such as ECG-gated blood-pool imaging have the advantage of being less invasive than contrast ventriculography and do not rely on geometrical assumptions about the shape of the ventricle. A study has been made of the inter-observer variation in estimates of ejection fraction and average and maximum systolic contraction rates using a micro-computer (VIP-450 Video Image Processor, Ohio-Nuclear Limited, Rugby) to analyse gated blood-pool images of the left ventricle. (author)

  20. A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF)

    DEFF Research Database (Denmark)

    Hasenfuß, Gerd; Hayward, Chris; Burkhoff, Dan

    2016-01-01

    BACKGROUND: Heart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, espec...

  1. Determinants of global left ventricular peak diastolic filling rate during rest and exercise in normal volunteers

    International Nuclear Information System (INIS)

    Filiberti, A.W.; Bianco, J.A.; Baker, S.P.; Doherty; Nalivaika, L.A.; King, M.A.; Alpert, J.S.

    1984-01-01

    Early peak diastolic filling rate (PFR) of the left ventricle (LV) is said to be a sensitive index of LV dysfunction in patients with coronary disease, hypertension and hypertrophic cardiomyopathy. Radionuclide (RN0 multigated PFR was measured in 20 normal volunteers (13 males, 7 females, mean age 31 yrs., range 20-43) at rest and during supine bicycle exercise conducted to a symptomatic end-point. At rest, RN PFR was 3.4 +- SD 0.4 end-diastolic vols./sec (range 3.1 - 3.6). During exercise all normal volunteers had a progressive and numerically and statistically significant increase in PFR. Stepwise multiple linear regression (BMPD2R) was applied to the rest and exercise PFR data to develop a linear model describing the main determinants of the RN PFR. The potential independent variables which were included in the model were heart rate (HR), ejection fraction (EF), systolic arterial pressure, systolic ejection rate and exercise stage. Ranking of variables for prediction of RN PFR, and exclusion of less important variables, was done by F value criteria. The final multivariate equation was: LVPFR = -3.84437 + 0.03834 HR + 0.07537 LVEF. The model fit was highly significant (p<0.001), and accounted for 89 per cent of variability in the PFR. The authors conclude that the left ventricular peak filling rate is critically determined by heart rate and by ejection fraction at rest and during exercise

  2. Left ventricular filling rate change as an earlier indicator than ejection fraction of chemotherapeutic cardiotoxicity in cancer paptents' nuclear medicine MUGA scans

    International Nuclear Information System (INIS)

    Miko, T.G.

    2004-01-01

    According to Wang Siegel has long suggested that an earlier indicator of damage to the hearts of cancer patients undergoing potentially cardiotoxic chemotherapy could be change in the left ventricular filling rate (LVFT) rather than dependence on the left ventricular ejection fraction (LVEF) as a measure for when to discontinue chemotherapy. Currently ejection fraction obtained by performing the nuclear medicine MUGA scan is the gold standard for determining further treatment of patients with these cardiotoxic agents. We are seeking to see if changes in filling rate (LVFR) are an earlier indicator of cardiotoxicity by performing a retrospective analysis of MUGA scans performed at our facility pre- and post-chemotherapy and performing a statistical analysis of changes in ejection fraction us filling rate in patients known to have cardiotoxic changes due to chemotherapy. (authors)

  3. Heart Failure with Preserved Ejection Fraction – Concept, Pathophysiology, Diagnosis and Challenges for Treatment

    Directory of Open Access Journals (Sweden)

    Lidija Veterovska Miljkovik

    2015-07-01

    Full Text Available Heart failure (HF with preserved left ventricular (LV ejection fraction (HFpEF occurs in 40 to 60% of the patients with HF, with a prognosis which is similar to HF with reduced ejection fraction (HFrEF. HFpEF pathophysiology is different from that of HFrEF, and has been characterized with diastolic dysfunction. Diastolic dysfunction has been defined with elevated left ventricular stiffness, prolonged iso-volumetric LV relaxation, slow LV filing and elevated LV end-diastolic pressure. Arterial hypertension occurs in majority cases with HFpEF worldwide. Patients are mostly older and obese. Diabetes mellitus and atrial fibrillation appear proportionally in a high frequency of patients with HFpEF. The HFpEF diagnosis is based on existence of symptoms and signs of heart failure, normal or approximately normal ejection and diagnosing of LV diastolic dysfunction by means of heart catheterization or Doppler echocardiography and/or elevated concentration of plasma natriuretic peptide. The present recommendations for HFpEF treatment include blood pressure control, heart chamber frequency control when atrial fibrillation exists, in some situations even coronary revascularization and an attempt for sinus rhythm reestablishment. Up to now, it is considered that no medication or a group of medications improve the survival of HFpEF patients. Due to these causes and the bad prognosis of the disorder, rigorous control is recommended of the previously mentioned precipitating factors for this disorder. This paper presents a universal review of the most important parameters which determine this disorder.

  4. Rapid estimation of left ventricular ejection fraction in acute myocardial infarction by echocardiographic wall motion analysis

    DEFF Research Database (Denmark)

    Berning, J; Rokkedal Nielsen, J; Launbjerg, J

    1992-01-01

    Echocardiographic estimates of left ventricular ejection fraction (ECHO-LVEF) in acute myocardial infarction (AMI) were obtained by a new approach, using visual analysis of left ventricular wall motion in a nine-segment model. The method was validated in 41 patients using radionuclide...

  5. Abnormal responses of ejection fraction to exercise, in healthy subjects, caused by region-of-interest selection

    International Nuclear Information System (INIS)

    Sorenson, S.G.; Caldwell, J.; Ritchie, J.; Hamilton, G.

    1981-01-01

    We performed serial exercise equilibrium radionuclide angiography in eight normal subjects with each subject executing three tests: control, after nitroglycerin, and after propranolol. The left-ventricular ejection fraction (EF) was calculated by two methods: (a) fixed region-of-interest (FROI) using a single end-diastolic ROI, and (b) variable region-of-interest (VROI) where an end-diastolic and end-systolic region of interest were used. Abnormal maximal EF responses occurred in five of eight subjects during control using FROI but in zero of eight employing VROI (p < 0.05). After nitroglycerin, three of eight subjects had abnormal responses by FROI, but zero of eight were abnormal by VROI (p < 0.05). After propranolol, blunted EF responses occurred in three of seven by both methods. Falsely abnormal EF responses to exercise RNA may occur due to the method of region-of-interest selection in normal subjects with normal or high ejection fractions

  6. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction

    Energy Technology Data Exchange (ETDEWEB)

    Messias, Leandro Rocha, E-mail: lmessias@cardiol.br; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Azevedo, Jader Cunha de [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Messias, Ana Carolina Nader Vasconcelos [Hospital Federal dos Servidores do Estado do Rio de Janeiro, Rio de Janeiro, RJ (Brazil); Maróstica, Elisabeth [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Mesquita, Claudio Tinoco [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Hospital Procardíaco, Rio de Janeiro, RJ (Brazil)

    2016-05-15

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO{sub 2}). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO{sub 2} and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.

  7. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction

    International Nuclear Information System (INIS)

    Messias, Leandro Rocha; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas; Azevedo, Jader Cunha de; Messias, Ana Carolina Nader Vasconcelos; Maróstica, Elisabeth; Mesquita, Claudio Tinoco

    2016-01-01

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO 2 ). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO 2 and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity

  8. Quantitative gated SPECT: the effect of reconstruction filter on calculated left ventricular ejection fractions and volumes

    International Nuclear Information System (INIS)

    Wright, Graham A.; McDade, Mark; Martin, William; Hutton, William

    2002-01-01

    Gated SPECT (GSPECT) offers the possibility of obtaining additional functional information from perfusion studies, including calculation of left ventricular ejection fraction (LVEF). The calculation of LVEF relies upon the identification of the endocardial surface, which will be affected by the spatial resolution and statistical noise in the reconstructed images. The aim of this study was to compare LVEFs and ventricular volumes calculated from GSPECT using six reconstruction filters. GSPECT and radionuclide ventriculography (RNVG) were performed on 40 patients; filtered back projection was used to reconstruct the datasets with each filter. LVEFs and volumes were calculated using the Cedars-Sinai QGS package. The correlation coefficient between RNVG and GSPECT ranged from 0.81 to 0.86 with higher correlations for smoother filters. The narrowest prediction interval was 11±2%. There was a trend towards higher LVEF values with smoother filters, the ramp filter yielding LVEFs 2.55±3.10% (p<0.001) lower than the Hann filter. There was an overall fall in ventricular volumes with smoother filters with a mean difference of 13.98±10.15 ml (p<0.001) in EDV between the Butterworth-0.5 and Butterworth-0.3 filters. In conclusion, smoother reconstruction filters lead to lower volumes and higher ejection fractions with the QGS algorithm, with the Butterworth-0.4 filter giving the highest correlation with LVEFs from RNVG. Even if the optimal filter is chosen the uncertainty in the measured ejection fractions is still too great to be clinically acceptable. (author)

  9. Right heart ejection fraction, ventricular volumes, and left to right cardiac shunt measurements with a conventional Anger camera in congenital heart disease

    International Nuclear Information System (INIS)

    Cook, S.A.; Go, R.T.; MacIntyre, W.J.; Moodie, D.S.; Houser, T.S.; Ceimo, J.; Underwood, D.; Yiannikas, J.

    1982-01-01

    The object of this investigation was to demonstrate that a conventional Anger camera can be used for measurement of right heart ejection fraction, ventricular volumes and left to right shunts in routine clinical determinations. The automatic selection of chamber and lung regions, the recirculation subtraction of recirculation, and the filtering of the right heart ejection fraction dilution curves are all done entirely without operator intervention. Thus, this entire evaluation has been incorporated into the routine procedures of patient care

  10. Measurement of right and left ventricular ejection fraction in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolf, I.; Qvist, J.; Mygind, T.; Jordening, H.; Dorph, S.; Munck, O.

    1983-08-01

    Three techniques for measurement of right (RVEF) and two techniques for left (LVEF) ventricular ejection fraction were evaluated in five dogs. RVEF was measured with a first-pass radionuclide technique using erythrocytes labelled in vitro with Technetium-99m methylene disphosphonate (MDP) and compared with RVEF measured with a thermodilution technique. Thermodilution-determined RVEF was compared with RVEF values measured with cine angiocardiography. LVEF was measured with a radionuclide ECG-gated equilibrium technique and compared with cine angiocardiography. Measurements were performed before and during a continuous infusion of dopamine. There was an excellent correlation between RVEF measured with the first-pass and the thermodilution technique. LVEF measured with the ECG-gated equilibrium technique correlated well with cine angiocardiography.

  11. Impact of Ejection Fraction on the Clinical Response to Cardiac Resynchronization Therapy in Mild Heart Failure

    DEFF Research Database (Denmark)

    Linde, Cecilia; Daubert, Claude; Abraham, William T

    2013-01-01

    Current guidelines recommend cardiac resynchronization therapy (CRT) in mild heart failure (HF) patients with QRS prolongation and ejection fraction (EF) ≤30%. To assess the effect of CRT in less severe systolic dysfunction, outcomes in the REsynchronization reVErses Remodeling in Systolic left v...

  12. B-Type Natriuretic Peptide and Prognosis in Heart Failure Patients With Preserved and Reduced Ejection Fraction

    NARCIS (Netherlands)

    van Veldhuisen, Dirk J.; Linssen, Gerard C. M.; Jaarsma, Tiny; van Gilst, Wiek H.; Hoes, Arno W.; Tijssen, Jan G. P.; Paulus, Walter J.; Voors, Adriaan A.; Hillege, Hans L.

    2013-01-01

    Objectives This study sought to determine the prognostic value of B-type natriuretic peptide (BNP) in patients with heart failure with preserved ejection fraction (HFPEF), in comparison to data in HF patients with reduced left ventricular (LV) EF ( Background Management of patients with HFPEF is

  13. Is cardiac resynchronization therapy an option in heart failure patients with preserved ejection fraction? Justification for the ongoing KaRen project.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars; Linde, Cecilia; Daubert, Jean-Claude

    2010-01-01

    The relevance of electrical and mechanical dyssynchrony has been demonstrated in heart failure with reduced ejection fraction. Preserved ejection fraction is present in as many as 50% of patients with chronic heart failure. Recent small studies suggest that both electrical and mechanical left ventricular dyssynchrony are sometimes present in patients with heart failure and preserved ejection fraction (HFPEF). These data remain controversial and a robust validation of this hypothesis has to be achieved. In the present paper, we review in detail the concepts and try to justify the ongoing KaRen registry. This is a prospective, multicentre, international, observational study to characterize the prevalence of electrical or mechanical dyssynchrony in HFPEF and the resultant effect on prognosis. Patients are enrolled currently at the time of an acute congestive episode. The diagnosis of HFPEF is made according to clinical data, natriuretic peptides and echocardiography for the measurement of ejection fraction. Once stabilized, patients return for a hospital check-up. They undergo clinical and biological evaluation, electrocardiography and Doppler echocardiography. Thereafter, patients are followed every six months, for at least 18 months for mortality, and heart failure-related and non-cardiovascular hospitalizations. KaRen aims to characterize electrical and mechanical dyssynchrony and to assess its prognostic impact in HFPEF. The results may improve our understanding of HFPEF and generate answers to the question of whether or not dyssynchrony could be a target for cardiac resynchronization therapy in HFPEF. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  14. Transcatheter treatment of heart failure with preserved or mildly reduced ejection fraction using a novel interatrial implant to lower left atrial pressure

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Reddy, Vivek; Kaye, David

    2014-01-01

    BACKGROUND: Heart failure with preserved or mildly reduced ejection fraction (HFpEF) is common and, to date, therapeutic options are limited. Increased left atrial pressure is a key contributor to the symptoms associated with HFpEF, particularly during physical activity. We report the 30-day...... outcome of patients treated with a novel device intended to lower left atrial pressure by creating an 8 mm permanent shunt in the atrial septum. METHODS AND RESULTS: Eleven patients were enrolled in the pilot trial. Key inclusion criteria were: EF >45%; baseline PCWP ≥15 mmHg (rest), or ≥ 25 mm...... patients, one class in five patients, and worsened by one class in one patient. No patient developed pulmonary hypertension. Two serious adverse events occurred; heart failure re-hospitalization, and implant malposition successfully treated with a new device. CONCLUSION: Contemporary management of HFp...

  15. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  16. Ergospirometry and Echocardiography in Early Stage of Heart Failure with Preserved Ejection Fraction and in Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Eduardo Lima Garcia

    2015-01-01

    Full Text Available Abstract Background: Heart failure with preserved ejection fraction is a syndrome characterized by changes in diastolic function; it is more prevalent among the elderly, women, and individuals with systemic hypertension (SH and diabetes mellitus. However, in its early stages, there are no signs of congestion and it is identified in tests by adverse remodeling, decreased exercise capacity and diastolic dysfunction. Objective: To compare doppler, echocardiographic (Echo, and cardiopulmonary exercise test (CPET variables - ergospirometry variables - between two population samples: one of individuals in the early stage of this syndrome, and the other of healthy individuals. Methods: Twenty eight outpatients diagnosed with heart failure according to Framingham’s criteria, ejection fraction > 50% and diastolic dysfunction according to the european society of cardiology (ESC, and 24 healthy individuals underwent Echo and CPET. Results: The group of patients showed indexed atrial volume and left ventricular mass as well as E/E’ and ILAV/A´ ratios significantly higher, in addition to a significant reduction in peak oxygen consumption and increased VE/VCO2 slope, even having similar left ventricular sizes in comparison to those of the sample of healthy individuals. Conclusion: There are significant differences between the structural and functional variables analyzed by Echo and CPET when comparing two population samples: one of patients in the early stage of heart failure with ejection fraction greater than or equal to 50% and another of healthy individuals.

  17. Mid-range Ejection Fraction Does Not Permit Risk Stratification Among Patients Hospitalized for Heart Failure.

    Science.gov (United States)

    Gómez-Otero, Inés; Ferrero-Gregori, Andreu; Varela Román, Alfonso; Seijas Amigo, José; Pascual-Figal, Domingo A; Delgado Jiménez, Juan; Álvarez-García, Jesús; Fernández-Avilés, Francisco; Worner Diz, Fernando; Alonso-Pulpón, Luis; Cinca, Juan; Gónzalez-Juanatey, José Ramón

    2017-05-01

    European Society of Cardiology heart failure guidelines include a new patient category with mid-range (40%-49%) left ventricular ejection fraction (HFmrEF). HFmrEF patient characteristics and prognosis are poorly defined. The aim of this study was to analyze the HFmrEF category in a cohort of hospitalized heart failure patients (REDINSCOR II Registry). A prospective observational study was conducted with 1420 patients classified according to ejection fraction as follows: HFrEF, < 40%; HFmrEF, 40%-49%; and HFpEF, ≥ 50%. Baseline patient characteristics were examined, and outcome measures were mortality and readmission for heart failure at 1-, 6-, and 12-month follow-up. Propensity score matching was used to compare the HFmrEF group with the other ejection fraction groups. Among the study participants, 583 (41%) had HFrEF, 227 (16%) HFmrEF, and 610 (43%) HFpEF. HFmrEF patients had a clinical profile similar to that of HFpEF patients in terms of age, blood pressure, and atrial fibrillation prevalence, but shared with HFrEF patients a higher proportion of male participants and ischemic etiology, and use of class I drugs targeting HFrEF. All other features were intermediate, and comorbidities were similar among the 3 groups. There were no significant differences in all-cause mortality, cause of death, or heart failure readmission. The similar outcomes were confirmed in the propensity score matched cohorts. The HFmrEF patient group has characteristics between the HFrEF and HFpEF groups, with more similarities to the HFpEF group. No between-group differences were observed in total mortality, cause of death, or heart failure readmission. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  19. Effects of omega-3 fatty acids on resting heart rate, heart rate recovery after exercise, and heart rate variability in men with healed myocardial infarctions and depressed ejection fractions.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Sastre, Antonio; Steinhaus, David M; Harris, William S

    2006-04-15

    We explored possible mechanisms by which recommended intakes of omega-3 fatty acids may decrease the risk for sudden cardiac death in patients with documented coronary heart disease. The cardioprotective effects of omega-3 fatty acids have been documented in epidemiologic and randomized controlled trials. These fatty acids are presumed to decrease susceptibility to fatal arrhythmias, but whether this is mediated by classic risk factors or direct cardiac mechanisms is not known. Eighteen white men with a history of myocardial infarction and ejection fractions <40% were randomized to placebo or omega-3 fatty acids (585 mg of docosahexaenoic acid and 225 mg of eicosapentaenoic acid) for two 4-month periods in a crossover design. At the end of each period, heart rate (HR), HR variability, and rate of HR recovery after exercise were determined, as were effects on arterial compliance, blood pressure, cardiac function, and fasting serum levels of lipids and inflammatory markers. Omega-3 fatty acids decreased HR at rest from 73 +/- 13 to 68 +/- 13 beats/min (p <0.0001) and improved 1-minute HR recovery after exercise (-27 +/- 10 to -32 +/- 12 beats/min, p <0.01). HR variability in the high-frequency band increased (p <0.02), but no change was noted in overall HR variability. There were no significant effects on blood pressure, arterial compliance, lipids, or inflammatory markers. These changes are consistent with an increase in vagal activity and may in part explain the observed decrease in risk for sudden cardiac death seen with omega-3 fatty acid supplementation.

  20. Quantification of the relative contribution of the different right ventricular wall motion components to right ventricular ejection fraction: the ReVISION method.

    Science.gov (United States)

    Lakatos, Bálint; Tősér, Zoltán; Tokodi, Márton; Doronina, Alexandra; Kosztin, Annamária; Muraru, Denisa; Badano, Luigi P; Kovács, Attila; Merkely, Béla

    2017-03-27

    Three major mechanisms contribute to right ventricular (RV) pump function: (i) shortening of the longitudinal axis with traction of the tricuspid annulus towards the apex; (ii) inward movement of the RV free wall; (iii) bulging of the interventricular septum into the RV and stretching the free wall over the septum. The relative contribution of the aforementioned mechanisms to RV pump function may change in different pathological conditions.Our aim was to develop a custom method to separately assess the extent of longitudinal, radial and anteroposterior displacement of the RV walls and to quantify their relative contribution to global RV ejection fraction using 3D data sets obtained by echocardiography.Accordingly, we decomposed the movement of the exported RV beutel wall in a vertex based manner. The volumes of the beutels accounting for the RV wall motion in only one direction (either longitudinal, radial, or anteroposterior) were calculated at each time frame using the signed tetrahedron method. Then, the relative contribution of the RV wall motion along the three different directions to global RV ejection fraction was calculated either as the ratio of the given direction's ejection fraction to global ejection fraction and as the frame-by-frame RV volume change (∆V/∆t) along the three motion directions.The ReVISION (Right VentrIcular Separate wall motIon quantificatiON) method may contribute to a better understanding of the pathophysiology of RV mechanical adaptations to different loading conditions and diseases.

  1. Isometric stress in cardiovascular magnetic resonance - a simple and easily replicable method of assessing cardiovascular differences not apparent at rest

    International Nuclear Information System (INIS)

    Mortensen, Kristian H.; Jones, Alexander; Steeden, Jennifer A.; Taylor, Andrew M.; Muthurangu, Vivek

    2016-01-01

    Isometric exercise may unmask cardiovascular disease not evident at rest, and cardiovascular magnetic resonance (CMR) imaging is proven for comprehensive resting assessment. This study devised a simple isometric exercise CMR methodology and assessed the hemodynamic response evoked by isometric exercise. A biceps isometric exercise technique was devised for CMR, and 75 healthy volunteers were assessed at rest, after 3-minute biceps exercise, and 5-minute of recovery using: (1) blood pressure (BP) and (2) CMR measured aortic flow and left ventricular function. Total peripheral resistance (SVR) and arterial compliance (TAC), cardiac output (CO), left ventricular volumes and function (ejection fraction, stroke volume, power output), blood pressure (BP), heart rate (HR), and rate pressure product were assessed at all time points. Image quality was preserved during stress. During exercise there were increases in CO (+14.9 %), HR (+17.0 %), SVR (+9.8 %), systolic BP (+22.4 %), diastolic BP (+25.4 %) and mean BP (+23.2 %). In addition, there were decreases in TAC (-22.0 %) and left ventricular ejection fraction (-6.3 %). Age and body mass index modified the evoked response, even when resting measures were similar. Isometric exercise technique evokes a significant cardiovascular response in CMR, unmasking physiological differences that are not apparent at rest. (orig.)

  2. Isometric stress in cardiovascular magnetic resonance - a simple and easily replicable method of assessing cardiovascular differences not apparent at rest

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Kristian H.; Jones, Alexander; Steeden, Jennifer A.; Taylor, Andrew M.; Muthurangu, Vivek [UCL Centre for Cardiovascular MR, UCL Institute of Cardiovascular Science, Level 6 Old Nurses Home, Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London (United Kingdom)

    2016-04-15

    Isometric exercise may unmask cardiovascular disease not evident at rest, and cardiovascular magnetic resonance (CMR) imaging is proven for comprehensive resting assessment. This study devised a simple isometric exercise CMR methodology and assessed the hemodynamic response evoked by isometric exercise. A biceps isometric exercise technique was devised for CMR, and 75 healthy volunteers were assessed at rest, after 3-minute biceps exercise, and 5-minute of recovery using: (1) blood pressure (BP) and (2) CMR measured aortic flow and left ventricular function. Total peripheral resistance (SVR) and arterial compliance (TAC), cardiac output (CO), left ventricular volumes and function (ejection fraction, stroke volume, power output), blood pressure (BP), heart rate (HR), and rate pressure product were assessed at all time points. Image quality was preserved during stress. During exercise there were increases in CO (+14.9 %), HR (+17.0 %), SVR (+9.8 %), systolic BP (+22.4 %), diastolic BP (+25.4 %) and mean BP (+23.2 %). In addition, there were decreases in TAC (-22.0 %) and left ventricular ejection fraction (-6.3 %). Age and body mass index modified the evoked response, even when resting measures were similar. Isometric exercise technique evokes a significant cardiovascular response in CMR, unmasking physiological differences that are not apparent at rest. (orig.)

  3. Awake craniotomy in a patient with ejection fraction of 10%: considerations of cerebrovascular and cardiovascular physiology.

    Science.gov (United States)

    Meng, Lingzhong; Weston, Stephen D; Chang, Edward F; Gelb, Adrian W

    2015-05-01

    A 37-year-old man with nonischemic 4-chamber dilated cardiomyopathy and low-output cardiac failure (estimated ejection fraction of 10%) underwent awake craniotomy for a low-grade oligodendroglioma resection under monitored anesthesia care. The cerebrovascular and cardiovascular physiologic challenges and our management of this patient are discussed. Published by Elsevier Inc.

  4. Left ventricular deformation at rest predicts exercise-induced elevation in pulmonary artery wedge pressure in patients with unexplained dyspnoea

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Santos, Mário; Rivero, Jose

    2017-01-01

    AIMS: Impaired left ventricular (LV) deformation despite preserved LV ejection fraction (LVEF) is common and predicts outcomes in heart failure with preserved LVEF. We hypothesized that impaired LV deformation at rest is a marker of impaired cardiac systolic and diastolic reserve, and aimed to de...

  5. Evaluation of right ventricular ejection fraction by first-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Left ventricular ejection fraction (LVEF) obtained by radionuclide angiocardiography is a convenient and good parameter of the left ventricular function. Right ventricular ejection fraction (RVEF) also seems to be a good parameter of the right ventricular function. RVEF calculated from volumetry with contrast right ventriculography is not necessarily correct because of the complex figure of the right ventricle. On the other hand, the method of calculation of RVEF with radionuclide angiocardiography has the advantage of being able to ignore the complexity of figure of RV, because RI counts extracted from the time-activity curve represent changes in ventricular volume. In this study, we developped an original method to calculate RVEF with first pass method. After setting of region of interest (ROI) of RV, background and ROI for correction of motion of tricuspid valve, we calculated RVEF with these time-activity curves, Since we found that too rapid infusion of RI made the time-activity curve of RV too steep, and too slow infusion of RI made the background of lung field too high, the appropriate infusion rate was required to get correct value of RVEF. In addition, the time-activity curve often became steep or flat in dependence of the speed of venous return and cardiac output of patients. In order to avoid the effect of infusion speed, the time-activity curve was fitted to linear curves and the value of RVEF was corrected. The validity of these methods was confirmed in our study. As the result, RVEF obtained with our methods appeared to have good correlation with that obtained from volumetry of contrast right ventriculography (r = 0.77) and to be very useful in clinical estimation of right ventricular function. (author)

  6. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  7. The hemodynamic effects of spinal block with low dose of bupivacaine and sufentanil in patients with low myocardial ejection fraction.

    Directory of Open Access Journals (Sweden)

    Mehdi Sanatkar

    2013-07-01

    Full Text Available The aim of this study was to assess the effect of spinal block with low dose of bupivacaine and sufentanil on patients with low cardiac output who underwent lower limb surgery. Fifteen patients who had ejection fraction less than 40% (group 1 were compared with 65 cases with ejection fraction more than 40% (group 2 in our study. Our subjects underwent spinal block with 7.5 mg hyperbaric bupivacaine 0.5% and 5 µg sufentanil. We recorded early events such as hypotension, bradycardia, vasopressor need and ST segment change in our cases. The average mean arterial pressure decreased 13% (110 mmHg to 95.7 mmHg in group 1 and 20% (160 mmHg to 128 mmHg in group 2 (P<0.001. Hypotension due to spinal anesthesia was observed in none of our subjects in both groups and none of our cases need to vasopressor support. All patients remained alert, and no ST segment changes were observed in two groups. In our study none of subjects complained of pain intraoperatively. The subjects were without complaints during the spinal anesthetic in both groups. Spinal block with low dose local anesthetic and sufentanil was a safe and effective method for lower limb surgery in patients with low ejection fraction.

  8. Changes in Cardiopulmonary Reserve and Peripheral Arterial Function Concomitantly with Subclinical Inflammation and Oxidative Stress in Patients with Heart Failure with Preserved Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Damien Vitiello

    2014-01-01

    Full Text Available Background. Changes in cardiopulmonary reserve and biomarkers related to wall stress, inflammation, and oxidative stress concomitantly with the evaluation of peripheral arterial blood flow have not been investigated in patients with heart failure with preserved ejection fraction (HFpEF compared with healthy subjects (CTL. Methods and Results. Eighteen HFpEF patients and 14 CTL were recruited. Plasma levels of inflammatory and oxidative stress biomarkers were measured at rest. Brain natriuretic peptide (BNP was measured at rest and peak exercise. Cardiopulmonary reserve was assessed using an exercise protocol with gas exchange analyses. Peripheral arterial blood flow was determined by strain gauge plethysmography. Peak VO2 (12.0±0.4 versus 19.1±1.1 mL/min/kg, P<0.001 and oxygen uptake efficiency slope (1.55±0.12 versus 2.06±0.14, P<0.05 were significantly decreased in HFpEF patients compared with CTL. BNP at rest and following stress, C-reactive-protein, interleukin-6, and TBARS were significantly elevated in HFpEF. Both basal and posthyperemic arterial blood flow were not significantly different between the HFpEF patients and CTL. Conclusions. HFpEF exhibits a severe reduction in cardiopulmonary reserve and oxygen uptake efficiency concomitantly with an elevation in a broad spectrum of biomarkers confirming an inflammatory and prooxidative status in patients with HFpEF.

  9. Global ejection fraction and phase analysis assessed by radionuclide angiography during exercise and after isoproterenol infusion

    International Nuclear Information System (INIS)

    Righetti, A.; Ratib, O.; Merier, G.; Widmann, T.; Donath, A.

    1983-01-01

    Radionuclide angiography obtained during and following Isoproterenol infusion is a new approach for detecting latent myocardial ischemia. It is very sensitive and could be considered as an alternative to conventional exercice radionuclide angiography. The data presented show that phase analysis assessment of regional systolic wall motion is a better indicator than global ejection fraction for quantifying left ventricular dysfunction

  10. Determination of left ventricular ejection fraction by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Hoeilund-Carlsen, P.F.; Rasmussen, S.; Hesse, B.; Dige-Petersen, H.; Folke, K.; Godtfredsen, J.; Jensen, G.; Fabricius, J.

    1982-01-01

    Radionuclide angiocardiography is a non-invasive gamma camera investigation for evaluation and quantification of heart performance. We investigated the reliability of the method in measuring left ventricular ejection fraction (EF). The accuracy was determined by measuring EF in 29 patients by both radionuclide angiocardiography and conventional single-plane cineventriculography. The two methods correlated well: r=0.92; y=0.86x+0.07. The precision of the method was evaluated as follows: The coefficient of variance was 6% for duplicate determinations performed on the same day (n=27) and 5% for determinations with 1-3 days interval (n=21). The interobserver variation expressed by the coefficient of variance was maximally 6% with the radionuclide method (n=29, three observers). The intraobserver variation was 4% compared to 9% with cineventriculography (P<0.01). Radionuclide angiocardiography is a reliable way of measuring EF. As the method is non-invasive, it is well suited for sequential determinations of EF in the same patient. (authors)

  11. Submaximal oxygen uptake kinetics, functional mobility, and physical activity in older adults with heart failure and reduced ejection fraction.

    Science.gov (United States)

    Hummel, Scott L; Herald, John; Alpert, Craig; Gretebeck, Kimberlee A; Champoux, Wendy S; Dengel, Donald R; Vaitkevicius, Peter V; Alexander, Neil B

    2016-07-01

    Submaximal oxygen uptake measures are more feasible and may better predict clinical cardiac outcomes than maximal tests in older adults with heart failure (HF). We examined relationships between maximal oxygen uptake, submaximal oxygen kinetics, functional mobility, and physical activity in older adults with HF and reduced ejection fraction. Older adults with HF and reduced ejection fraction (n = 25, age 75 ± 7 years) were compared to 25 healthy age- and gender-matched controls. Assessments included a maximal treadmill test for peak oxygen uptake (VO2peak), oxygen uptake kinetics at onset of and on recovery from a submaximal treadmill test, functional mobility testing [Get Up and Go (GUG), Comfortable Gait Speed (CGS), Unipedal Stance (US)], and self-reported physical activity (PA). Compared to controls, HF had worse performance on GUG, CGS, and US, greater delays in submaximal oxygen uptake kinetics, and lower PA. In controls, VO2peak was more strongly associated with functional mobility and PA than submaximal oxygen uptake kinetics. In HF patients, submaximal oxygen uptake kinetics were similarly associated with GUG and CGS as VO2peak, but weakly associated with PA. Based on their mobility performance, older HF patients with reduced ejection fraction are at risk for adverse functional outcomes. In this population, submaximal oxygen uptake measures may be equivalent to VO2 peak in predicting functional mobility, and in addition to being more feasible, may provide better insight into how aerobic function relates to mobility in older adults with HF.

  12. Bi-temporal 3D active appearance models with applications to unsupervised ejection fraction estimation

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Pedersen, Dorthe

    2005-01-01

    in four-dimensional MRI. The theoretical foundation of our work is the generative two-dimensional Active Appearance Models by Cootes et al., here extended to bi-temporal, three-dimensional models. Further issues treated include correction of respiratory induced slice displacements, systole detection......, and a texture model pruning strategy. Cross-validation carried out on clinical-quality scans of twelve volunteers indicates that ejection fraction and cardiac blood pool volumes can be estimated automatically and rapidly with accuracy on par with typical inter-observer variability....

  13. The reverse remodeling response to sacubitril/valsartan therapy in heart failure with reduced ejection fraction.

    Science.gov (United States)

    Martens, Pieter; Beliën, Hanne; Dupont, Matthias; Vandervoort, Pieter; Mullens, Wilfried

    2018-05-17

    Major classes of medical therapy for heart failure with reduced ejection fraction (HFrEF) induce reverse remodeling. The revere remodeling response to sacubitril/valsartan remains unstudied. We performed a single-center, prospective assessor-blinded study to determine the reverse remodeling response of sacubitril/valsartan therapy in HFrEF patients with a class I indication (New York heart Association [NYHA]-class II-IV, Left ventricular ejection fraction [LVEF] sacubitril/valsartan were optimized to individual tolerance. Echocardiographic images were assessed offline by 2 investigators blinded to both the clinical data and timing of echocardiograms. One-hundred-twenty-five HFrEF patients (66 ± 10 years) were prospectively included. The amount of RAS-blocker before and after switch to sacubitril/valsartan was similar(P = .290), indicating individual optimal dosing of sacubitril/valsartan. Over a median(IQR) follow-up of 118(77-160) days after initiation of sacubitril/valsartan, LVEF improved (29.6 ± 6% vs 34.8 ± 6%; P sacubitril/valsartan leading to more reverse remodeling. Switching therapy in eligible HFrEF patients from a RAS-blocker to sacubitril/valsartan induces beneficial reverse remodeling of both metrics of systolic as diastolic function. © 2018 John Wiley & Sons Ltd.

  14. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  15. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  16. Effect of mental stress on left ventricular ejection fraction and its relationship to the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Toru; Kuwabara, Yoichi; Watanabe, Satoshi; Nakaya, Jiro; Hasegawa, R.; Shikama, Takeshi; Matsuno, Kouki; Mikami, Yuji; Fujii, Kiyotaka; Saito, Toshihiro; Masuda, Yoshiaki [Dept. of Internal Medicine, Chiba Univ. (Japan)

    2000-12-01

    To evaluate the relationship between the mental stress-induced decrease in left ventricular ejection fraction (LVEF) and the severity of exercise-induced ischaemia, 20 patients with stable coronary artery disease (CAD) underwent radionuclide ventriculography during mental stress testing and stress myocardial perfusion single-photon emission tomography (SPET). We also examined whether changes in haemodynamic and neurohormonal parameters are related to changes in LVEF during mental stress. The LVEF decreased from 54.8%{+-}17.7% to 49.8%{+-}16.2% with mental stress (P<0.0005). Ten of the 20 patients (50.0%) had a {>=}5% decrease in LVEF. The remaining ten patients had no or a <5% decrease in LVEF. There was a significant correlation between the change in LVEF during mental stress and the size of the reversible defect on stress myocardial perfusion SPET (r=-0.80, P<0.0005), with close regional correspondence (75% identical). This correlation was less strong in the 12 patients with a total defect score at rest of <10 (r=-0.69, P=0.014) than in the eight patients with a total defect score at rest of {>=}10 (r=-0.94, P=0.001). The changes in blood pressure and heart rate were not significantly correlated with the change in LVEF, but the percent change in adrenaline concentration correlated with the change in LVEF. It is suggested that mental stress impairs systolic function by inducing transient myocardial ischaemia. The effect of neurohormonal responses during mental stress on LV systolic function may also be important in patients with CAD. (orig.)

  17. Effect of mental stress on left ventricular ejection fraction and its relationship to the severity of coronary artery disease

    International Nuclear Information System (INIS)

    Kuroda, Toru; Kuwabara, Yoichi; Watanabe, Satoshi; Nakaya, Jiro; Hasegawa, R.; Shikama, Takeshi; Matsuno, Kouki; Mikami, Yuji; Fujii, Kiyotaka; Saito, Toshihiro; Masuda, Yoshiaki

    2000-01-01

    To evaluate the relationship between the mental stress-induced decrease in left ventricular ejection fraction (LVEF) and the severity of exercise-induced ischaemia, 20 patients with stable coronary artery disease (CAD) underwent radionuclide ventriculography during mental stress testing and stress myocardial perfusion single-photon emission tomography (SPET). We also examined whether changes in haemodynamic and neurohormonal parameters are related to changes in LVEF during mental stress. The LVEF decreased from 54.8%±17.7% to 49.8%±16.2% with mental stress (P<0.0005). Ten of the 20 patients (50.0%) had a ≥5% decrease in LVEF. The remaining ten patients had no or a <5% decrease in LVEF. There was a significant correlation between the change in LVEF during mental stress and the size of the reversible defect on stress myocardial perfusion SPET (r=-0.80, P<0.0005), with close regional correspondence (75% identical). This correlation was less strong in the 12 patients with a total defect score at rest of <10 (r=-0.69, P=0.014) than in the eight patients with a total defect score at rest of ≥10 (r=-0.94, P=0.001). The changes in blood pressure and heart rate were not significantly correlated with the change in LVEF, but the percent change in adrenaline concentration correlated with the change in LVEF. It is suggested that mental stress impairs systolic function by inducing transient myocardial ischaemia. The effect of neurohormonal responses during mental stress on LV systolic function may also be important in patients with CAD. (orig.)

  18. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  19. CMR reference values for left ventricular volumes, mass, and ejection fraction using computer-aided analysis : The Framingham Heart Study

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Materials and Methods We examined data from 1494 members of the Framingham Heart

  20. Changing the treatment of heart failure with reduced ejection fraction: clinical use of sacubitril-valsartan combination

    Science.gov (United States)

    Kaplinsky, Edgardo

    2016-01-01

    Despite significant therapeutic advances, patients with chronic heart failure (HF) remain at high risk of morbidity and mortality. Sacubitril valsartan (previously known as LCZ696) is a new oral agent approved for the treatment of symptomatic chronic heart failure in adults with reduced ejection fraction. It is described as the first in class angiotensin receptor neprilysin inhibitor (ARNI) since it incorporates the neprilysin inhibitor, sacubitril and the angiotensin II receptor antagonist, valsartan. Neprilysin is an endopeptidase that breaks down several vasoactive peptides including natriuretic peptides (NPs), bradykinin, endothelin and angiotensin II (Ang-II). Therefore, a natural consequence of its inhibition is an increase of plasmatic levels of both, NPs and Ang-II (with opposite biological actions). So, a combined inhibition of these both systems (Sacubitril / valsartan) may enhance the benefits of NPs effects in HF (natriuresis, diuresis, etc) while Ang-II receptor is inhibited (reducing vasoconstriction and aldosterone release). In a large clinical trial (PARADIGM-HF with 8442 patients), this new agent was found to significantly reduce cardiovascular and all cause mortality as well as hospitalizations due to HF (compared to enalapril). This manuscript reviews clinical evidence for sacubitril valsartan, dosing and cautions, future directions and its considered place in the therapy of HF with reduced ejection fraction. PMID:28133468

  1. Automatic determination of the regional ejection fraction of the left ventricle (gated bloodpool)

    International Nuclear Information System (INIS)

    Feser, J.A.

    1982-01-01

    The left ventricular volume curve and the ejection fraction are calculated according to the ''sliding region of interest'' method in which the ventricle contour is redetermined for every single picture of the various phases of the heart beat. The original set of data, consisting of 32 pictures in 64 x 64 matrix resolution, is processed by a three-dimensional filtering process in space (x,y) and time (t). The ventricle contour is determined by convolution of the filtered images with a 7-point Laplacian operator in 4 independent directions. The atrial and ventricular phase histograms are then calculated on the basis of this contour. (WU) [de

  2. Comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-04-01

    First-pass radionuclide angiography (FPRA) in the 30/sup 0/ right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45/sup 0/ left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA.

  3. Clinical tolerability of generic versus brand beta blockers in heart failure with reduced left ventricular ejection fraction: a retrospective cohort from heart failure clinic.

    Science.gov (United States)

    Chanchai, Rattanachai; Kanjanavanit, Rungsrit; Leemasawat, Krit; Amarittakomol, Anong; Topaiboon, Paleerat; Phrommintikul, Arintaya

    2018-01-01

    Background: Beta-blockers have been shown to decrease mortality and morbidity in heart failure with reduced ejection fraction (HFrEF) patients. However, the side effects are also dose-related, leading to the underdosing. Cost constraint may be one of the limitations of appropriate beta-blocker use; this can be improved with generic drugs. However, the effects in real life practice have not been investigated. Methods and results: This study aimed to compare the efficacy and safety of generic and brand beta-blockers in HFrEF patients. We performed a retrospective cohort analysis in HFrEF patients who received either generic or brand beta-blocker in Chiang Mai Heart Failure Clinic. The primary endpoint was the proportion of patients who received at least 50% target dose of beta-blocker between generic and brand beta-blockers. Adverse events were secondary endpoints. 217 patients (119 and 98 patients received generic and brand beta-blocker, respectively) were enrolled. There were no differences between groups regarding age, gender, etiology of heart failure, New York Heart Association (NYHA) functional class, left ventricular ejection fraction (LVEF), rate of receiving angiotensin converting enzyme inhibitor (ACEI), angiotensin recepter blocker (ARB), or spironolactone. Patients receiving brand beta-blockers had lower resting heart rate at baseline (74.9 and 84.2 bpm, p  = .001). Rate of achieved 50% target dose and target daily dose did not differ between groups (40.4 versus 44.5% and 48.0 versus 55.0%, p  > .05, respectively). Rate of side effects was not different between groups (32.3 versus 29.5%, p  > .05) and the most common side effect was hypotension. Conclusion: This study demonstrated that beta-blocker tolerability was comparable between brand and generic formulations. Generic or brand beta-blockers should be prescribed to HFrEF patients who have no contraindications.

  4. Estimation of global and regional ejection fraction of the left ventricle using a fully digitalised technique

    International Nuclear Information System (INIS)

    Tuengerthal, S.; Reifart, N.; Standke, R.; Lang, J.; Kollath, J.; Riemann, H.E.; Frankfurt Univ.; Frankfurt Univ.

    1984-01-01

    Subtraction angiocardiography (DSAK) with a fully digitalised system (DR 960) provides a well defined demonstration of the left ventricle after peripheral venous contrast injection. Cardiac volume and ejection fractions were calculated by a dedicated software programme and the findings correlated with cine ventriculography (CA) (r=0.91), biplane echo cardiography (2 DE) (r=0.77) and radionucleid ventriculography (RNV) (r=0.85); the method can be used even with reduced cardiac output (EF [de

  5. Delayed Repolarization Underlies Ventricular Arrhythmias in Rats With Heart Failure and Preserved Ejection Fraction.

    Science.gov (United States)

    Cho, Jae Hyung; Zhang, Rui; Kilfoil, Peter J; Gallet, Romain; de Couto, Geoffrey; Bresee, Catherine; Goldhaber, Joshua I; Marbán, Eduardo; Cingolani, Eugenio

    2017-11-21

    Heart failure with preserved ejection fraction (HFpEF) represents approximately half of heart failure, and its incidence continues to increase. The leading cause of mortality in HFpEF is sudden death, but little is known about the underlying mechanisms. Dahl salt-sensitive rats were fed a high-salt diet (8% NaCl) from 7 weeks of age to induce HFpEF (n=38). Rats fed a normal-salt diet (0.3% NaCl) served as controls (n=13). Echocardiograms were performed to assess systolic and diastolic function from 14 weeks of age. HFpEF-verified and control rats underwent programmed electrical stimulation. Corrected QT interval was measured by surface ECG. The mechanisms of ventricular arrhythmias (VA) were probed by optical mapping, whole-cell patch clamp to measure action potential duration and ionic currents, and quantitative polymerase chain reaction and Western blotting to investigate changes in ion channel expression. After 7 weeks of a high-salt diet, 31 of 38 rats showed diastolic dysfunction and preserved ejection fraction along with signs of heart failure and hence were diagnosed with HFpEF. Programmed electric stimulation demonstrated increased susceptibility to VA in HFpEF rats ( P hearts demonstrated prolonged action potentials ( P hearts. Susceptibility to VA was markedly increased in rats with HFpEF. Underlying abnormalities include QT prolongation, delayed repolarization from downregulation of potassium currents, and multiple reentry circuits during VA. Our findings are consistent with the hypothesis that potassium current downregulation leads to abnormal repolarization in HFpEF, which in turn predisposes to VA and sudden cardiac death. © 2017 American Heart Association, Inc.

  6. Cost-effectiveness Analysis of Sacubitril/Valsartan vs Enalapril in Patients With Heart Failure and Reduced Ejection Fraction.

    Science.gov (United States)

    Gaziano, Thomas A; Fonarow, Gregg C; Claggett, Brian; Chan, Wing W; Deschaseaux-Voinet, Celine; Turner, Stuart J; Rouleau, Jean L; Zile, Michael R; McMurray, John J V; Solomon, Scott D

    2016-09-01

    The angiotensin receptor neprilysin inhibitor sacubitril/valsartan was associated with a reduction in cardiovascular mortality, all-cause mortality, and hospitalizations compared with enalapril. Sacubitril/valsartan has been approved for use in heart failure (HF) with reduced ejection fraction in the United States and cost has been suggested as 1 factor that will influence the use of this agent. To estimate the cost-effectiveness of sacubitril/valsartan vs enalapril in the United States. Data from US adults (mean [SD] age, 63.8 [11.5] years) with HF with reduced ejection fraction and characteristics similar to those in the PARADIGM-HF trial were used as inputs for a 2-state Markov model simulated HF. Risks of all-cause mortality and hospitalization from HF or other reasons were estimated with a 30-year time horizon. Quality of life was based on trial EQ-5D scores. Hospital costs combined Medicare and private insurance reimbursement rates; medication costs included the wholesale acquisition cost for sacubitril/valsartan and enalapril. A discount rate of 3% was used. Sensitivity analyses were performed on key inputs including: hospital costs, mortality benefit, hazard ratio for hospitalization reduction, drug costs, and quality-of-life estimates. Hospitalizations, quality-adjusted life-years (QALYs), costs, and incremental costs per QALY gained. The 2-state Markov model of US adult patients (mean age, 63.8 years) calculated that there would be 220 fewer hospital admissions per 1000 patients with HF treated with sacubitril/valsartan vs enalapril over 30 years. The incremental costs and QALYs gained with sacubitril/valsartan treatment were estimated at $35 512 and 0.78, respectively, compared with enalapril, equating to an incremental cost-effectiveness ratio (ICER) of $45 017 per QALY for the base-case. Sensitivity analyses demonstrated ICERs ranging from $35 357 to $75 301 per QALY. For eligible patients with HF with reduced ejection fraction, the Markov

  7. Effects of gender, ejection fraction and weight on cardiac force development in patients undergoing cardiac surgery--an experimental examination.

    Science.gov (United States)

    Bening, Constanze; Weiler, Helge; Vahl, Christian-Friedrich

    2013-11-18

    It has long been recognized that differences exist between men and women in the impact of risc factors, symptoms, development and outcome of special diseases like the cardiovascular disease. Gender determines the cardiac baseline parameters like the number of cardiac myocyte, size and demand and may suggest differences in myofilament function among genders, which might be pronounced under pathological conditions. Does gender impact and maybe impair the contractile apparatus? Are the differences more prominent when other factors like weight, age, ejection fraction are added?Therefore we performed a study on 36 patients (21 male, 15 female) undergoing aortic valve replacement (AVR) or aortocoronary bypass operation (CABG) to examine the influence of gender, ejection fraction, surgical procedure and body mass index (BMI) on cardiac force development. Tissue was obtained from the right auricle and was stored in a special solution to prevent any stretching of the fibers. We used the skinned muscle fiber model and single muscle stripes, which were mounted on the "muscle machine" and exposed to a gradual increase of calcium concentration calculated by an attached computer program. 1.) In general female fibers show more force than male fibers: 3.9 mN vs. 2.0 mN (p = 0.03) 2.) Female fibers undergoing AVR achieved more force than those undergoing CABG operation: 5.7 mN vs. 2.8 mN (p = 0.02) as well as male fibers with AVR showed more force values compared to those undergoing CABG: 2.0 mN vs. 0.5 mN (p = 0.01). 3.) Male and female fibers of patients with EF > 55% developed significantly more force than from those with less ejection fraction than 30%: p = 0.002 for the male fibers (1.6 vs. 2.8 mN) and p = 0.04 for the female fibers (5.7 vs. 2.8 mN). 4.) Patients with a BMI between 18 till 25 develop significant more force than those with a BMI > 30: Females 5.1 vs. 2.6 mN; p 0.03, Males 3.8 vs. 0.8 mN; p 0.04). Our data suggest that female patients undergoing AVR or CABG

  8. The reproducibility and variability of sequential left ventricular ejection fraction measurements by the nuclear stethoscope

    International Nuclear Information System (INIS)

    Kurata, Chinori; Hayashi, Hideharu; Kobayashi, Akira; Yamazaki, Noboru

    1986-01-01

    We evaluated the reproducibility and variability of sequential left ventricular ejection fraction (LVEF) measurements by the nuclear stethoscope in 72 patients. The group as a whole demonstrated excellent reproducibility (r = 0.96). However, repeat LVEF measurements by the nuclear stethoscope at 5-minute interval showed around 9 % absolute difference, at 95 % confidence levels, from one measurement to the next. The finding indicates that a change in LVEF greater than 9 % is necessary for determining an acute effect of an intervention in individual cases. (author)

  9. Measurement and comparison of left ventricular ejection fraction utilizing first transit and gated scintiangiography

    International Nuclear Information System (INIS)

    Fletcher, J.W.; Herbig, F.K.; Daly, J.L.; Walter, K.E.

    1975-01-01

    Paired serial radionuclide scans were used for determinations of left ventricular ejection fraction (LVEF) in open chest dogs with constant cardiac output and varying ventricular rates following the left atrial injection of 99m-Tc human serum albumin. Values of LVEF obtained by first transit (high frequency) data analysis and ECG-gated scintiphotography were obtained over a wide range of ventricular rate and stroke volume. The results of this study show no significant difference in LVEF as determined by both of these methods of data acquisition and analysis and demonstrate the feasibility of rapid serial determination of LVEF by radioisotope techniques

  10. Prediction of improvement in global left ventricular function in patients with chronic coronary artery disease and impaired left ventricular function: rest thallium-201 SPET versus low-dose dobutamine echocardiography

    International Nuclear Information System (INIS)

    Pace, L.; Salvatore, M.; Perrone-Filardi, P.; Dellegrottaglie, S.; Prastaro, M.; Crisci, T.; Ponticelli, M.P.; Piscione, F.; Chiariello, M.; Storto, G.; Della Morte, A.M.

    2000-01-01

    Accurate assessment of myocardial viability permits selection of patients who would benefit from myocardial revascularization. Currently, rest-redistribution thallium-201 scintigraphy and low-dose dobutamine echocardiography are among the most used techniques for the identification of viable myocardium. Thirty-one consecutive patients (all men, mean age 60±8 years) with chronic coronary artery disease and reduced left ventricular ejection fraction (31%±7%) were studied. Rest 201 Tl single-photon emission tomography (SPET), low-dose dobutamine echocardiography and radionuclide angiography were performed before revascularization. Radionuclide angiography and echocardiography were repeated after revascularization. An a/dyskinetic segment was considered viable on 201 Tl SPET when tracer uptake was >65%, while improvement on low-dose dobutamine echocardiography was considered a marker of viability. Increase in global ejection fraction was considered significant at ≥5%. In identifying viable segments, rest 201 Tl SPET showed higher sensitivity than low-dose dobutamine echocardiography (72% vs 53%, P 201 Tl SPET in group 1 than in group 2 (2.6±1.9 vs 0.6±1.2, P 201 Tl SPET and post-revascularization changes in ejection fraction (r=0.52, P 201 Tl SPET had a higher sensitivity (82% vs 53%, P=0.07) and showed a trend towards higher accuracy and specificity (77% vs 58%, and 71% vs 64%, respectively) as compared with low-dose dobutamine echocardiography. In conclusion, these findings suggest that when severely reduced global function is present, rest 201 Tl SPET evaluation of viability is more accurate than low-dose dobutamine echocardiography for the identification of patients who will benefit most from revascularization. (orig.)

  11. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    International Nuclear Information System (INIS)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki; Itoh, Haruki; Taniguchi, Koichi.

    1993-01-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: 1) Cut-off level was fixed at 70% of first channel, 2) Cut-off level at 75%, and 3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author)

  12. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki (Tokyo Medical and Dental Univ. (Japan). School of Medicine); Itoh, Haruki; Taniguchi, Koichi

    1993-06-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: (1) Cut-off level was fixed at 70% of first channel, (2) Cut-off level at 75%, and (3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author).

  13. Noninvasive prediction of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fraction.

    Science.gov (United States)

    Abd-El-Aziz, Tarek A

    2012-01-01

    The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Calculation of cardiac pressures using left ventricular ejection fraction (LVEF) derived from radionuclide angiography

    International Nuclear Information System (INIS)

    Hommer, E.

    1981-01-01

    An attempt has been made to develop formulas to determine cardiac pressures in an undisturbed flow in patients without valvular or shunt diseases. These are based entirely on the results of left ventricular ejection fraction rates, permitting pressure analysis of several compartments at the same tine. According to BORER et al. they also enable determination of left ventricular 'Functional Reserve' after bycycle exercise as well as left ventricular 'Relaxation Reserve'. They support the views of NYHA in determining the grades of cardiac insufficiency proving the system- and low-pressure participation. A single formula for pulmonary flow can determine the pulmonary arterial pressure. The left ventricular enddiastolic pressure can also be exclusively calculated by values of left ventricular functions, thus both formulas may be used in disorders of the mitral valves. The possibility to calculate pressures of all the compartments of the heart from left ventricular ejection rate shows, that in undisturbed flow global heart function depends on left ventricular function. Therefore the mutual dependence of these formulas presents an intercompartimental pressure regulation of the heart through pulmonary flow and pulmonary vascular pressure, which leaves an aspect of autonomous cardiac regulation open to discussion. (orig.) [de

  15. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  16. Mass ejections from the solar corona into interplanetary space

    International Nuclear Information System (INIS)

    Hildner, E.

    1977-01-01

    Mass ejections from the corona are common occurrances, as observations with the High Altitude Observatory's white light coronagraph aboard Skylab showed. During 227 days of operation in 1973 and 1974 at least 77 mass ejections were observed and as many more probably occurred unobserved. It is suggested that the frequency of ejections varies with the solar cycle and that ejections may contribute 10 percent or more of the total solar mass efflux to the interplanetary medium at solar maximum. Since ejections are confined to relatively low latitudes, their fractional mass flux contribution is greater near the ecliptic than far from it. From the behavior of ejecta, we can estimate the magnitude of the force driving them through the corona. It is also suggested that loop-shaped ejection - the largest fraction of ejections - are driven, primarily, by magnetic forces. By comparison, gas pressure forces are negligible, and forces due to wave pressure are completely inadequate. That magnetic forces are important is consistent with observation that ejections seem to come, primarily, from regions where the magnetic field is more intense and more complex than elsewhere. Indeed, ejections are associated with phenomena (flares and eruptive prominences) which occur over lines separating regions of opposite polarities. (Auth.)

  17. A comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    International Nuclear Information System (INIS)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-01-01

    First-pass radionuclide angiography (FPRA) in the 30 0 right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45 0 left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA. (orig.)

  18. Predictors and progression of aortic stenosis in patients with preserved left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Ersbøll, Mads; Schulte, Phillip J; Al Enezi, Fawaz

    2015-01-01

    We aimed to characterize the hemodynamic progression of aortic stenosis (AS) in a contemporary unselected cohort of patients with preserved left ventricular ejection fraction. Current guidelines recommend echocardiographic surveillance of hemodynamic progression. However, limited data exist...... reported, a significant proportion of patients with mild and moderate AS progressed to higher grades within the currently recommended time windows for echocardiographic follow-up....... on the expected rate of progression and whether clinical variables are associated with accelerated progression in contemporarily managed patients with AS. We conducted a retrospective analysis of patients presenting with AS and explored the trajectory of AS mean gradient over time using generalized estimating...

  19. Varying effects of recommended treatments for heart failure with reduced ejection fraction

    DEFF Research Database (Denmark)

    Thomsen, Marius Mark; Lewinter, Christian; Køber, Lars

    2016-01-01

    The aim of this paper is to evaluate the treatment effects of recommended drugs and devices on key clinical outcomes for patients with heart failure with reduced ejection fraction (HFREF). Randomized controlled trials (RCTs) listed in the 2012 HF guideline from the European Society of Cardiology...... as well as the 2013 HF guideline from the American College of Cardiology Foundation and American Heart Association were evaluated for use in the meta-analysis. RCTs written in English evaluating recommended drugs and devices for the treatment of patients with HFREF were included. Meta-analyses, based...... on the outcomes of all-cause mortality and hospitalization because of HF, were performed with relative risk ratio as the effect size. In the identified 47 RCTs, patients were on average 63 years old and 22% were female. Drugs targeting the renin-angiotensin-aldosterone system, beta-blockers, cardiac...

  20. Determination of differences in the left ventricular ejection fraction (LVEF) by radionuclides and echocardiography pre and post treatment with anthracycline in pediatric patients with oncology diagnostic of the La Raza Medical Center

    International Nuclear Information System (INIS)

    Veras R, H.

    2003-01-01

    The objective of this work was to correlate the left ventricular ejection fraction determine by radionuclide angiocardiography and echocardiography in pediatric patients under anthracycline treatment. Material and methods: 41 patients were studied with range age from 3 to 14 years, with oncology diagnostic that were treated with anthracycline. Radionuclide angiocardiography and echocardiography were performed before an after anthracycline administration to determine the changes in the Ieft ventricular ejection fraction. Results: Anthracycline treatment caused no changes in the electrocardiography, echocardiogram and radionuclide angiocardiography. Conclusions: In our study anthracycline treatment caused no changes in the electrocardiography, echocardiography and both radionuclide angiocardiography techniques, first-pass and equilibrium. A high correlation was obtaining when left ventricular ejection fraction is compared between radionuclide angiocardiography and echocardiogram. (Author)

  1. Non-invasive measurement of stroke volume and left ventricular ejection fraction. Radionuclide cardiography compared with left ventricular cardioangiography

    DEFF Research Database (Denmark)

    Kelbaek, H; Svendsen, J H; Aldershvile, J

    1988-01-01

    The stroke volume (SV) was determined by first passage radionuclide cardiography and the left ventricular ejection fraction (LVEF) by multigated radionuclide cardiography in 20 patients with ischemic heart disease. The results were evaluated against those obtained by the invasive dye dilution or ...... are reliable. The discrepancy between the non-invasive and invasive LVEF values raises the question, whether LVEF is overestimated by cardioangiography or underestimated by radionuclide cardiography....

  2. Response of left ventricular ejection fraction to recovery from general anesthesia: measurement by gated radionuclide angiography

    International Nuclear Information System (INIS)

    Coriat, P.; Mundler, O.; Bousseau, D.; Fauchet, M.; Rous, A.C.; Echter, E.; Viars, P.

    1986-01-01

    To test the hypothesis that, after anesthesia for noncardiac surgical procedures, the increased cardiac work during recovery induces wall motion and ejection fraction (EF) abnormalities in patients with mild angina pectoris, gated radionuclide angiography was performed in patients undergoing simple cholecystectomy under narcotic-relaxant general anesthesia. The ejection fraction was determined during anesthesia at the end of surgery, and then determined 3 min and 3 hr after extubation. A new angiography was performed 24 hr later, and a myocardial scintigraphy (Thallium 201) was performed during infusion of the coronary vasodilator, dipyridamole. In the first part of the investigation, eight patients without coronary artery disease (CAD) (group 1) and 20 patients with mild angina (group 2) were studied. In the second part of the study, seven patients (group 3) with mild angina pectoris received an intravenous infusion of 0.4 microgram X kg-1 X min-1 of nitroglycerin started before surgery and gradually decreased 4 hr after extubation. In group 1, EF remained unchanged at recovery. In contrast in group 2, EF responded abnormally to recovery: EF decreased from 55% during anesthesia to 45% 3 min after extubation (P less than 0.001). Patients in group 3, who received intravenous nitroglycerin, showed no change of EF at recovery. This study demonstrates that recovery from general anesthesia causes abnormalities in left ventricular function in patients suffering from CAD. These abnormalities are prevented by prophylactic intravenous nitroglycerin

  3. Assessment of cardiac performance with quantitative radionuclide angiocardiography: sequential left ventricular ejection fraction, normalized left ventricular ejection rate, and regional wall motion

    International Nuclear Information System (INIS)

    Marshall, R.C.; Berger, H.J.; Costin, J.C.; Freedman, G.S.; Wolberg, J.; Cohen, L.S.; Gotischalk, A.; Zaret, B.L.

    1977-01-01

    Sequential quantitative first pass radionuclide angiocardiograms (RA) were used to measure left ventricular ejection fraction (LVEF) and left ventricular ejection rate (LVER), and to assess regional wall motion (RWM) in the anterior (ANT) and left anterior oblique (LAO) positions. Studies were obtained with a computerized multicrystal scintillation camera suitable for acquiring high count-rate data. Background was determined in a new fashion by selecting frames temporally from the left ventricular region of interest time-activity curve. A ''representative'' cardiac cycle was formed by summing together counts over three to six cardiac cycles. From this background corrected, high count-rate ''representative''cardiac cycle, LVEF, LVER, and RWM were determined. In 22 patients with normal sinus rhythm in the absence of significant valvular regurgitation, RA LVEF correlated well with that measured by contrast angiography (r = 0.95). LVER correlated well with LVEF measured at contrast angiography (r = 0.90) and allowed complete separation of those with normal (LVER = 3.4 +- 0.17 sec -1 ) and abnormal (LVER = 1.22 +- 0.11 sec -1 ) (P < 0.001) left ventricular performance. This separation was independent of background. Isoproterenol infusion in five normal subjects caused LVER to increase by 81 +- 17% while LVEF increased by 10 +- 2.0%. RWM was correctly defined in 21/22 patients and 89% of left ventricular segments with abnormal wall motion

  4. Cost-Effectiveness of Sacubitril-Valsartan in Patients With Heart Failure With Reduced Ejection Fraction.

    Science.gov (United States)

    Sandhu, Alexander T; Ollendorf, Daniel A; Chapman, Richard H; Pearson, Steven D; Heidenreich, Paul A

    2016-11-15

    Sacubitril-valsartan therapy reduces cardiovascular mortality compared with enalapril therapy in patients with heart failure with reduced ejection fraction. To evaluate the cost-effectiveness of sacubitril-valsartan versus angiotensin-converting enzyme inhibitor therapy in patients with chronic heart failure. Markov decision model. Clinical trials, observational analyses, reimbursement data from the Centers for Medicare & Medicaid Services, drug pricing databases, and Centers for Disease Control and Prevention life tables. Patients at an average age of 64 years, New York Heart Association (NYHA) class II to IV heart failure, and left ventricular ejection fraction of 0.40 or less. Lifetime. Societal. Treatment with sacubitril-valsartan or lisinopril. Life-years, quality-adjusted life-years (QALYs), costs, heart failure hospitalizations, and incremental cost-effectiveness ratios. The sacubitril-valsartan group experienced 0.08 fewer heart failure hospitalization, 0.69 additional life-year, 0.62 additional QALY, and $29 203 in incremental costs, equating to a cost per QALY gained of $47 053. The cost per QALY gained was $44 531 in patients with NYHA class II heart failure and $58 194 in those with class III or IV heart failure. Sacubitril-valsartan treatment was most sensitive to the duration of improved outcomes, with a cost per QALY gained of $120 623 if the duration was limited to the length of the trial (median, 27 months). No variations in other parameters caused the cost to exceed $100 000 per QALY gained. The benefit of sacubitril-valsartan is based on a single clinical trial. Treatment with sacubitril-valsartan provides reasonable value in reducing cardiovascular mortality and morbidity in patients with NYHA class II to IV heart failure. U.S. Department of Veterans Affairs and Institute for Clinical and Economic Review.

  5. Risk factors for readmission to hospital in adult patients with heart failure and reduced ejection fraction

    DEFF Research Database (Denmark)

    Schjødt, Inge; Larsen, Palle; Johnsen, Søren Paaske

    2017-01-01

    REVIEW QUESTION/OBJECTIVE:: The objective of this systematic review is to identify and synthesize the best available evidence on risk factors associated with hospital readmission at different time points within the first year after heart failure (HF) hospitalization in patients suffering from HF...... with reduced ejection fraction (EF).More specifically, the question is: what are the risk factors for the prediction of hospital readmission within seven, 15, 30, 60, 90, 180 and 365 days of discharge in hospitalized patients with HF with reduced EF aged 18 years or older?...

  6. Role of Myocardial Collagen in Severe Aortic Stenosis With Preserved Ejection Fraction and Symptoms of Heart Failure.

    Science.gov (United States)

    Echegaray, Kattalin; Andreu, Ion; Lazkano, Ane; Villanueva, Iñaki; Sáenz, Alberto; Elizalde, María Reyes; Echeverría, Tomás; López, Begoña; Garro, Asier; González, Arantxa; Zubillaga, Elena; Solla, Itziar; Sanz, Iñaki; González, Jesús; Elósegui-Artola, Alberto; Roca-Cusachs, Pere; Díez, Javier; Ravassa, Susana; Querejeta, Ramón

    2017-10-01

    We investigated the anatomical localization, biomechanical properties, and molecular phenotype of myocardial collagen tissue in 40 patients with severe aortic stenosis with preserved ejection fraction and symptoms of heart failure. Two transmural biopsies were taken from the left ventricular free wall. Mysial and nonmysial regions of the collagen network were analyzed. Myocardial collagen volume fraction (CVF) was measured by picrosirius red staining. Young's elastic modulus (YEM) was measured by atomic force microscopy in decellularized slices to assess stiffness. Collagen types I and III were measured as C I VF and C III VF, respectively, by confocal microscopy in areas with YEM evaluation. Compared with controls, patients exhibited increased mysial and nonmysial CVF and nonmysial:mysial CVF ratio (P < .05). In patients, nonmysial CVF (r = 0.330; P = .046) and the nonmysial:mysial CVF ratio (r = 0.419; P = .012) were directly correlated with the ratio of maximal early transmitral flow velocity in diastole to early mitral annulus velocity in diastole. Both the C I VF:C III VF ratio and YEM were increased (P ≤ .001) in nonmysial regions compared with mysial regions in patients, with a direct correlation (r = 0.895; P < .001) between them. These findings suggest that, in patients with severe aortic stenosis with preserved ejection fraction and symptoms of heart failure, diastolic dysfunction is associated with increased nonmysial deposition of collagen, predominantly type I, resulting in increased extracellular matrix stiffness. Therefore, the characteristics of collagen tissue may contribute to diastolic dysfunction in these patients. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  7. High-Intensity Interval Training in Patients With Heart Failure With Reduced Ejection Fraction.

    Science.gov (United States)

    Ellingsen, Øyvind; Halle, Martin; Conraads, Viviane; Støylen, Asbjørn; Dalen, Håvard; Delagardelle, Charles; Larsen, Alf-Inge; Hole, Torstein; Mezzani, Alessandro; Van Craenenbroeck, Emeline M; Videm, Vibeke; Beckers, Paul; Christle, Jeffrey W; Winzer, Ephraim; Mangner, Norman; Woitek, Felix; Höllriegel, Robert; Pressler, Axel; Monk-Hansen, Tea; Snoer, Martin; Feiereisen, Patrick; Valborgland, Torstein; Kjekshus, John; Hambrecht, Rainer; Gielen, Stephan; Karlsen, Trine; Prescott, Eva; Linke, Axel

    2017-02-28

    Small studies have suggested that high-intensity interval training (HIIT) is superior to moderate continuous training (MCT) in reversing cardiac remodeling and increasing aerobic capacity in patients with heart failure with reduced ejection fraction. The present multicenter trial compared 12 weeks of supervised interventions of HIIT, MCT, or a recommendation of regular exercise (RRE). Two hundred sixty-one patients with left ventricular ejection fraction ≤35% and New York Heart Association class II to III were randomly assigned to HIIT at 90% to 95% of maximal heart rate, MCT at 60% to 70% of maximal heart rate, or RRE. Thereafter, patients were encouraged to continue exercising on their own. Clinical assessments were performed at baseline, after the intervention, and at follow-up after 52 weeks. Primary end point was a between-group comparison of change in left ventricular end-diastolic diameter from baseline to 12 weeks. Groups did not differ in age (median, 60 years), sex (19% women), ischemic pathogenesis (59%), or medication. Change in left ventricular end-diastolic diameter from baseline to 12 weeks was not different between HIIT and MCT ( P =0.45); left ventricular end-diastolic diameter changes compared with RRE were -2.8 mm (-5.2 to -0.4 mm; P =0.02) in HIIT and -1.2 mm (-3.6 to 1.2 mm; P =0.34) in MCT. There was also no difference between HIIT and MCT in peak oxygen uptake ( P =0.70), but both were superior to RRE. However, none of these changes was maintained at follow-up after 52 weeks. Serious adverse events were not statistically different during supervised intervention or at follow-up at 52 weeks (HIIT, 39%; MCT, 25%; RRE, 34%; P =0.16). Training records showed that 51% of patients exercised below prescribed target during supervised HIIT and 80% above target in MCT. HIIT was not superior to MCT in changing left ventricular remodeling or aerobic capacity, and its feasibility remains unresolved in patients with heart failure. URL: http

  8. 13N-Ammonia pet-derived ventricular synchrony correlates with myocardial perfusion reserve better than left ventricular ejection fraction : A study in infarcted patients

    NARCIS (Netherlands)

    Juarez-Orozco, Luis Eduardo; Slart, Riemer; Tio, Rene A.; Inarra-Talboy, Fernando; Monroy, Andrea; Ayala-German, AnaGabriela; Dierckx, Rudi A.; Rosas, Erick Alexanderson

    2016-01-01

    Background: PET myocardial perfusion allows myocardial perfusion reserve (MPR) quantification as well as left ventricular ejection fraction (LVEF) and synchrony estimation through phase analysis. There is a relationship between MPR and LVEF and both have proven prognostic value in coronary artery

  9. Effect of Vericiguat, a Soluble Guanylate Cyclase Stimulator, on Natriuretic Peptide Levels in Patients With Worsening Chronic Heart Failure and Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Gheorghiade, Mihai; Greene, Stephen J; Butler, Javed

    2015-01-01

    IMPORTANCE: Worsening chronic heart failure (HF) is a major public health problem. OBJECTIVE: To determine the optimal dose and tolerability of vericiguat, a soluble guanylate cyclase stimulator, in patients with worsening chronic HF and reduced left ventricular ejection fraction (LVEF). DESIGN, ...

  10. Two-dimensional global longitudinal strain is superior to left ventricular ejection fraction in prediction of outcome in patients with left-sided infective endocarditis

    DEFF Research Database (Denmark)

    Lauridsen, Trine Kiilerich; Alhede, Christina; Crowley, Anna Lisa

    2018-01-01

    BACKGROUND: Impaired cardiac function is the main predictor of poor outcome in infective endocarditis (IE). Global longitudinal strain (GLS) derived from two-dimensional strain echocardiography has proven superior in prediction of long-term outcome as compared to left ventricular ejection fraction...

  11. Nonischemic changes in right ventricular function on exercise. Do normal volunteers differ from patients with normal coronary arteries

    International Nuclear Information System (INIS)

    Caplin, J.L.; Maltz, M.B.; Flatman, W.D.; Dymond, D.S.

    1988-01-01

    Factors other than ischemia may alter right ventricular function both at rest and on exercise. Normal volunteers differ from cardiac patients with normal coronary arteries with regard to their left ventricular response to exercise. This study examined changes in right ventricular function on exercise in 21 normal volunteers and 13 patients with normal coronary arteries, using first-pass radionuclide angiography. There were large ranges of right ventricular ejection fraction in the two groups, both at rest and on exercise. Resting right ventricular ejection fraction was 40.2 +/- 10.6% (mean +/- SD) in the volunteers and 38.6 +/- 9.7% in the patients, p = not significant, and on exercise rose significantly in both groups to 46.1 +/- 9.9% and 45.8 +/- 9.7%, respectively. The difference between the groups was not significant. In both groups some subjects with high resting values showed large decreases in ejection fraction on exercise, and there were significant negative correlations between resting ejection fraction and the change on exercise, r = -0.59 (p less than 0.01) in volunteers, and r = -0.66 (p less than 0.05) in patients. Older volunteers tended to have lower rest and exercise ejection fractions, but there was no difference between normotensive and hypertensive patients in their rest or exercise values. In conclusion, changes in right ventricular function on exercise are similar in normal volunteers and in patients with normal coronary arteries. Some subjects show decreases in right ventricular ejection fraction on exercise which do not appear to be related to ischemia

  12. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera

    DEFF Research Database (Denmark)

    Haarmark, Christian; Haase, Christine; Jensen, Maria Maj

    2016-01-01

    age and both left and right ventricular volumes in women (r = -0.4, P right end systolic ventricular volume in men (r = -0.3, P = .001). CONCLUSION: A set of reference values for cardiac evaluation prior to chemotherapy in cancer patients without other known cardiopulmonary......BACKGROUND: Estimation of left ventricular ejection fraction (LVEF) using equilibrium radionuclide angiography is an established method for assessment of left ventricular function. The purpose of this study was to establish normative data on left and right ventricular volumes and ejection fraction......, using cadmium-zinc-telluride SPECT camera. METHODS AND RESULTS: From routine assessments of left ventricular function in 1172 patients, we included 463 subjects (194 men and 269 women) without diabetes, previous potentially cardiotoxic chemotherapy, known cardiovascular or pulmonary disease. The lower...

  13. Influence of left ventricular hypertrophy on infarct size and left ventricular ejection fraction in ST-elevation myocardial infarction

    International Nuclear Information System (INIS)

    Małek, Łukasz A.; Śpiewak, Mateusz; Kłopotowski, Mariusz; Petryka, Joanna; Mazurkiewicz, Łukasz; Kruk, Mariusz; Kępka, Cezary; Miśko, Jolanta; Rużyłło, Witold; Witkowski, Adam

    2012-01-01

    Background: Left ventricular hypertrophy (LVH) predisposes to larger infarct size, which may be underestimated by the left ventricular ejection fraction (LVEF) due to supranormal systolic performance often present in patients with LVH. The aim of the study was to compare infarct size and LVEF in patients with ST-segment elevation myocardial infarction (STEMI) and increased left ventricular mass on cardiac magnetic resonance (CMR). Methods: The study included unselected group of 52 patients (61 ± 11 years, 69% male) with first STEMI who had CMR after median 5 days from the onset of the event. Left ventricular hypertrophy (LVH) was defined as left ventricular mass index exceeding 95th percentile of references values for age and gender. Infarct size was assessed with means of late gadolinium enhancement (LGE). Results: LVH was found in 16 patients (31%). In comparison to the rest of the group, patients with LVH had higher absolute and relative infarct mass (p = 0.002 and p = 0.02, respectively). LVH was related to higher prevalence of microvascular obstruction and myocardial haemorrhage and higher number of LV segments with transmural necrosis (p = 0.02, p = 0.01 and p = 0.01, respectively). Despite marked difference in the infarct size between both studied subgroups there was no difference in LVEF and mean number of dysfunctional LV segments. Conclusions: Patients with LVH undergoing STEMI have larger infarct size underestimated by the LV systolic performance in comparison to patients without LVH.

  14. Assessment of relationship between regional perfusion and ventricular function in patients with severely depressed ejection fraction

    International Nuclear Information System (INIS)

    Teresinska, A.; Konieczna, S.; Szumilak, B.; Gosiewska-Marcinkowska, E.; Potocka, J.

    1998-01-01

    Patients with low ventricular (LV) ejection fraction (EF) and with regional or global LV dysfunction, considered for myocardial revascularization, are often submitted to myocardial perfusion study to ptrove perfusion preserved and to approximate viability. The aim of this work is to evaluate, to what extent SPECT with Tc-99m-MIBI (SPECT-MIBI) additionally differentiatesa and enlarges the information on LV contractility achieved from radioisotopic ventriculography (RNV). Seventy-three patients with EF=0.11-0.35 (mean: 0.26 ± 0.06, calculated from RNV) were studied. Planar gated RNV and SPECT-MIBI were performed within 2 months (mean: 15 ± 14 days). RNV, after in vivo red cells labeling with Tc-99m, was recorded in rest in LAO45 and RAO30 views. Global EF and contractility of 5 regions (anterior, posterior, lateral walls, septum and apex) were evaluated. Assessment was performed by means of LV in 'cine' mode,m ED and ES outlines and amplitude-phase images. Regional contractility abnormalities were classified as dyskinesis, akinesis and hypokinesis. SPECT-MIBI was performed in rest and stress. Perfusion abnormalities in 5 above mentioned regions was classified as large (more intense than 50% of myocardial maximum) or small persistent defects (DEFpers), large or small partially reversible defects (DEFpart-rev), large or small completely reversible defects (DEFrev). Hypokinesis was detected in 23-35 regions (65%) , dyskinesis - in 63 (17%), akinesis - in 37 (10%), normokinesis - in 27 (7%). In dyskinetic regions, there existed large DEFpers (79%) or large DEFpart-rev (21%). In akinetic regions, there also existed large DEFpers (68%) or large DEFpart-rev (32%). In hypokinetic regions, there were no perfusion defects (31% of regions), small DEFpers, DEFrev and DEFpart-rev (42%) and also large DEFpers (27%). In most of normokinetic regions, different types of perfusion defects were observed (large DEFpers existed in 26% of regions). In summary: In dyskinetic and akinetic

  15. Cardiac lipid content is unresponsive to a physical activity training intervention in type 2 diabetic patients, despite improved ejection fraction

    Directory of Open Access Journals (Sweden)

    Leiner Tim

    2011-05-01

    Full Text Available Abstract Background Increased cardiac lipid content has been associated with diabetic cardiomyopathy. We recently showed that cardiac lipid content is reduced after 12 weeks of physical activity training in healthy overweight subjects. The beneficial effect of exercise training on cardiovascular risk is well established and the decrease in cardiac lipid content with exercise training in healthy overweight subjects was accompanied by improved ejection fraction. It is yet unclear whether diabetic patients respond similarly to physical activity training and whether a lowered lipid content in the heart is necessary for improvements in cardiac function. Here, we investigated whether exercise training is able to lower cardiac lipid content and improve cardiac function in type 2 diabetic patients. Methods Eleven overweight-to-obese male patients with type 2 diabetes mellitus (age: 58.4 ± 0.9 years, BMI: 29.9 ± 0.01 kg/m2 followed a 12-week training program (combination endurance/strength training, three sessions/week. Before and after training, maximal whole body oxygen uptake (VO2max and insulin sensitivity (by hyperinsulinemic, euglycemic clamp was determined. Systolic function was determined under resting conditions by CINE-MRI and cardiac lipid content in the septum of the heart by Proton Magnetic Resonance Spectroscopy. Results VO2max increased (from 27.1 ± 1.5 to 30.1 ± 1.6 ml/min/kg, p = 0.001 and insulin sensitivity improved upon training (insulin stimulated glucose disposal (delta Rd of glucose improved from 5.8 ± 1.9 to 10.3 ± 2.0 μmol/kg/min, p = 0.02. Left-ventricular ejection fraction improved after training (from 50.5 ± 2.0 to 55.6 ± 1.5%, p = 0.01 as well as cardiac index and cardiac output. Unexpectedly, cardiac lipid content in the septum remained unchanged (from 0.80 ± 0.22% to 0.95 ± 0.21%, p = 0.15. Conclusions Twelve weeks of progressive endurance/strength training was effective in improving VO2max, insulin sensitivity

  16. Validation of rest and exercise radionuclide angiography in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Gosiewska-Marcinkowska, E.; Rawczynska-Englert, I.; Szumilak, B.; Konieczna, S.; Rozycka-Chrzanowska, B.

    1992-01-01

    The aim of the study was to evaluate the significance of rest and stress test using radionuclide angiography (RA) in assessment of left ventricular (LV) function in the patients with aortic regurgitation (AR). In 32 patients we analyzed pre and 12 months after aortic valve replacement (AVR) the clinical data (including LV cavity dimension, LV hypertrophy, relative heart volume - RHV, the value of diastolic pressure) and the RA at rest and during supine stress test. We compared the clinical data with eject fraction (EF) and rest (EFr), at exercise (EFex) and ΔEF=EFex-EFr. Results show good correlation between clinical data and EF. Conclusions: 1) exercise RA is an useful method of estimation of LV function and after AVR; 2) early evaluation of the reserve of the LV allows to establish the appropriate time for AVR even before the signs of insufficiency of the LV are revealed. (author). 8 refs, 2 tabs

  17. Noncardiac Comorbidities in Heart Failure With Reduced Versus Preserved Ejection Fraction

    Science.gov (United States)

    Mentz, Robert J.; Kelly, Jacob P.; von Lueder, Thomas G.; Voors, Adriaan A.; Lam, Carolyn S. P.; Cowie, Martin R.; Kjeldsen, Keld; Jankowska, Ewa A.; Atar, Dan; Butler, Javed; Fiuzat, Mona; Zannad, Faiez; Pitt, Bertram; O’Connor, Christopher M.

    2014-01-01

    Heart failure patients are classified by ejection fraction (EF) into distinct groups: heart failure with preserved EF (HFpEF) or heart failure with reduced EF (HFrEF). Although patients with heart failure commonly have multiple comorbidities that complicate management and may adversely affect outcomes, their role in the HFpEF and HFrEF groups is not well-characterized. This review summarizes the role of noncardiac comorbidities in patients with HFpEF versus HFrEF, emphasizing prevalence, underlying pathophysiologic mechanisms, and outcomes. Pulmonary disease, diabetes mellitus, anemia, and obesity tend to be more prevalent in HFpEF patients, but renal disease and sleep-disordered breathing burdens are similar. These comorbidities similarly increase morbidity and mortality risk in HFpEF and HFrEF patients. Common pathophysiologic mechanisms include systemic and endomyocardial inflammation with fibrosis. We also discuss implications for clinical care and future HF clinical trial design. The basis for this review was discussions between scientists, clinical trialists, and regulatory representatives at the 10th Global CardioVascular Clinical Trialists Forum. PMID:25456761

  18. Relationship between exercise capacity and left ventricular function at rest in patients with heart failure. An ambulatory left ventricular monitoring study; Relazione tra capacita' di esercizio e funzione ventricolare sinistra a riposo nei pazienti con insufficienza cardiaca. Studio mediante monitoraggio continuo radionuclidico della funzione ventricolare sinistra

    Energy Technology Data Exchange (ETDEWEB)

    Pace, L.; Cuocolo, A.; Salvatore, M. [Naples Univ. Federico 2., Naples (Italy). Medicina Nucleare; Centro di Medicina Nucleare, Naples (Italy); Nappi, A.; Imbriaco, M; Varrone, A. [Naples Univ. Federico 2., Naples (Italy). Medicina Nucleare; Romano, M.; Trimarco, B. [Naples Univ., Federico 2., Naples (Italy). Medicina Interna

    2000-09-01

    Purpose of this work is to evaluate the relationship of systolic and diastolic function at rest to exercise capacity. Seventeen patients with ischemic heart failure were included in the study. Ambulatory left ventricular monitoring at rest and during upright exercise with combined analysis of pulmonary gas exchange was performed. Ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, and peak filling rate were measured. Significant positive correlations were found between rest ejection fraction and peak oxygen consumption (r=.60, p<.01), peak cardiac output (r=.67, p<.005). On the other hand, peak filling rate at rest showed a significant inverse correlation with peak end-diastolic (r=.48, p<.05) and end-systolic (r=-.66, p<.005) volumes. The patients were then sub grouped into two groups according to their rest ejection fraction (lower or higher than 40%). In the group with ejection fraction less than 40% a significant correlation was observed between rest ejection fraction and both peak stroke volume (r=-.66, p<.05) and peak ejection fraction (r=.69, p<.05). In the same group of patients an inverse correlation was found between peak filling rate and both end-diastolic (r=.65, p<.05) and end-systolic (r=.82, p<.005) volumes. The results of the present study suggest that exercise capacity is related to left ventricular function at rest and that rest diastolic function might be a determinant of left ventricular function during exercise in patients with heart failure. [Italian] Scopo di questo studio e' valutare se la capacita' di esercizio, determinata mediante il consumo di ossigeno e la funzione ventricolare sinistra, sia correlata alla funzione ventricolare sinistra a riposo nei pazienti con insufficienza cardiaca. Sono stati studiati 17 pazienti con insufficienza cardiaca di origine ischemica. Tutti sono stati sottoposti a monitoraggio radionuclidico continuo della funzione ventricolare sinistra in combinazione con

  19. Computer-based assessment of right ventricular regional ejection fraction in patients with repaired Tetralogy of Fallot

    Science.gov (United States)

    Teo, S.-K.; Wong, S. T.; Tan, M. L.; Su, Y.; Zhong, L.; Tan, Ru-San

    2015-03-01

    After surgical repair for Tetralogy of Fallot (TOF), most patients experience long-term complications as the right ventricle (RV) undergoes progressive remodeling that eventually affect heart functions. Thus, post-repair surgery is required to prevent further deterioration of RV functions that may result in malignant ventricular arrhythmias and mortality. The timing of such post-repair surgery therefore depends crucially on the quantitative assessment of the RV functions. Current clinical indices for such functional assessment measure global properties such as RV volumes and ejection fraction. However, these indices are less than ideal as regional variations and anomalies are obscured. Therefore, we sought to (i) develop a quantitative method to assess RV regional function using regional ejection fraction (REF) based on a 13-segment model, and (ii) evaluate the effectiveness of REF in discriminating 6 repaired TOF patients and 6 normal control based on cardiac magnetic resonance (CMR) imaging. We observed that the REF for the individual segments in the patient group is significantly lower compared to the control group (P < 0.05 using a 2-tail student t-test). In addition, we also observed that the aggregated REF at the basal, mid-cavity and apical regions for the patient group is significantly lower compared to the control group (P < 0.001 using a 2-tail student t-test). The results suggest that REF could potentially be used as a quantitative index for assessing RV regional functions. The computational time per data set is approximately 60 seconds, which demonstrates our method's clinical potential as a real-time cardiac assessment tool.

  20. Qualitative Resting Coronary Pressure Wave Form Analysis to Predict Fractional Flow Reserve.

    Science.gov (United States)

    Matsumura, Mitsuaki; Maehara, Akiko; Johnson, Nils P; Fearon, William F; De Bruyne, Bernard; Oldroyd, Keith G; Pijls, Nico H J; Jenkins, Paul; Ali, Ziad A; Mintz, Gary S; Stone, Gregg W; Jeremias, Allen

    2018-03-27

    To evaluate the predictability of resting distal coronary pressure wave forms for fractional flow reserve (FFR). Resting coronary wave forms were qualitatively evaluated for the presence of (i) dicrotic notch; (ii) diastolic dipping; and (iii) ventricularization. In a development cohort (n=88) a scoring system was developed that was then applied to a validation cohort (n=428) using a multivariable linear regression model to predict FFR and receiver operating characteristics (ROC) to predict FFR ≤0.8. In the development cohort, all 3 qualitative parameters were independent predictors of FFR. However, in a multivariable linear regression model in the validation cohort, qualitative wave form analysis did not further improve the ability of resting distal coronary to aortic pressure ratio (Pd/Pa) (p=0.80) or instantaneous wave-free ratio (iFR) (p=0.26) to predict FFR. Using ROC, the area under the curve of resting Pd/Pa (0.86 versus 0.86, P=0.08) and iFR (0.86 versus 0.86, P=0.26) did not improve by adding qualitative analysis. Qualitative coronary wave form analysis showed moderate classification agreement in predicting FFR but did not add substantially to the resting pressure gradients Pd/Pa and iFR; however, when discrepancies between quantitative and qualitative analyses are observed, artifact or pressure drift should be considered.

  1. Extracellular matrix remodeling in patients with ischemic chronic heart failure with preserved ejection fraction

    Directory of Open Access Journals (Sweden)

    V. D. Syvolap

    2015-04-01

    Full Text Available Aim. To identify features, relationships between parameters of the extracellular matrix and renal function in 110 patients with ischemic chronic heart failure the activity of collagen metabolism markers (MMP-9, TIMP-1, PICP, cystatin C, structural and functional parameters of the heart were studied using ELISA, echocardiography. Results. It was established that imbalance in the system MMP/TIMP in ischemic heart failure with preserved left ventricular ejection fraction leads to disruption of the extracellular matrix structural functional sufficiency, increases functional failure and is associated with impaired renal function. Conclusion. Correlation analysis showed significant relationships between MMP/TIMP and GFR, cystatin C, indicating that the significant role of extracellular matrix imbalance in the development of renal dysfunction in patients with ischemic chronic heart failure.

  2. Measurement of left ventricular ejection fraction in pediatric patients using the nuclear stethoscope

    International Nuclear Information System (INIS)

    Spicer, R.L.; Rabinovitch, M.; Rosenthal, A.; Pitt, B.

    1984-01-01

    Left ventricular (LV) ejection fraction (EF) was measured in 25 patients, aged 2 weeks to 20 years (mean 8.6 years), using a portable nonimaging scintillation stethoscope. Technically satisfactory studies were obtained in 23 patients. LVEF was validated by cineangiography in 19 patients and by standard gated blood pool scintigraphy in 4. EF measured by the nuclear stethoscope correlated well with values obtained by cineangiography or scintigraphy over a wide range of EF values (18 to 79%). In children younger than 5 years (n . 11), the correlation was less satisfactory than in those older than 5 years. Although modifications in the instrument and further clinical trials with the stethoscope are needed before the device becomes clinically useful to pediatric cardiologists, our data indicate that the nuclear stethoscope can provide reliable assessment of LVEF in pediatric patients

  3. Clinical significance of right ventricular ejection fraction in cases with atrial septal defect

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Seiki; Nishimura, Tsunehiko; Hayashida, Kouhei; Uehara, Toshiisa

    1989-04-01

    Right ventricular ejection fraction (RVEF) assessed by cardiac radionuclide angiography has been applied to evaluate ventricular function such as ischemic, valvular and congenital heart disease. Using this modality, previous reports also suggest that there is good correlation between RVEF and mean pulmonary arterial pressure (mPA) from catheterization findings in mitral valvular disease and chronic obstructive lung disease. In this study, cardiac RI angiography were performed on 33 adult patients with atrial septal defect (ASD). RVEF is not so good correlation (r=-0.42) with mPA, but in cases within pulmonary to systemic ratio (Qp/Qs) less than 2.0 limits, there is good correlation between RVEF and mPA (n=9, r=-0.71). As a conclusion, in ASD, both afterload assessed by mPA and preload assessed by Qp/Qs decrease RVEF. (author).

  4. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    International Nuclear Information System (INIS)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-01-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis

  5. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-07-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis.

  6. Asymmetrically thickened posterior wall is associated with decline of ejection fraction after stress on adenosine stress/rest thallium-201 gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Lee, Won Woo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2004-07-01

    LV parameters (LVEF. ESVI and EDVI) on adenosine stress/rest thallium-201 gated myocardial SPECT (gSPECT) are various from stress to rest. We investigated the reason why they were various in patients without coronary artery disease. Seventy-one patients(M:F=32:39, age 58.1{+-}9.7yrs), who underwent gSPECT and coronary angiography (CAG) due to chest pain or preoperative evaluation were included. CAG results were normal or insignificant. Exclusion criteria were atrial fibrillation, thyroid disease, primary cardiomyopathy, myocardial bridge, LBBB, MI, and valvular heart disease. Patients were calssified into 3 groups by EF difference ({delta}EF=rest-stress EF) on gSPECT : group1 ({delta}EF{>=}10), group2 (0 {<=}{delta}EF<10), and group3 ({delta}EF<0). LV parameters on gSPECT and thicknesses of IVS (interventricular septum) and LVPW (left ventricular posterior wall) on echocardiography were compared among the 3 groups. Myocardial perfusion status were normal or mild reversible/persistent perfusion defect in 76.1% (54/71). LVEFs at stress were not different among all 3 groups : 59.3{+-}8.54% in group 1 (61.3{+-}10.22% in group 2 and 64.8{+-}7.58% in group 3 (p>0.05). But LVEF at rest was smaller in group 3 (58.7{+-}8.38%) than the other groups (72.5{+-}8.77% in group1 and 66.7{+-}10.6% in group2) (p<0.01). EDVIs and ESVI at stress were larger than those at rest in all groups (p<0.05) except ESVI in group 3 (16.2{+-}6.21ml at stress and 17.5{+-}6.41ml at rest, p<0.01), and that was attributed to EF<0 in group 3. In echocardiographical analysis, group 3 had significantly increased wall thickness of LVPW (10.7{+-}1.2mm versus 9.4{+-}1.6mm, p=0.01) and decreased wall thickness ratio of IVS/LVPW (0.963{+-}0.102 versus 1.048{+-}0.104, p=0.035) than group 1. In patients without coronary artery disease, LVEF, EDVI and ESVI on gSPECT were various and decline of LVEF from stress to rest was caused by unnormalized ESVI . Asymmetrically thickened LVPW may play a crucial role and

  7. Atrial fibrillation in heart failure with preserved ejection fraction: Insights into mechanisms and therapeutics.

    Science.gov (United States)

    Patel, Ravi B; Vaduganathan, Muthiah; Shah, Sanjiv J; Butler, Javed

    2017-08-01

    Atrial fibrillation (AF) and heart failure (HF) often coexist, and the outcomes of patients who have both AF and HF are considerably worse than those with either condition in isolation. Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous clinical entity and accounts for approximately one-half of current HF. At least one-third of patients with HFpEF are burdened by comorbid AF. The current understanding of the relationship between AF and HFpEF is limited, but the clinical implications are potentially important. In this review, we explore 1) the pathogenesis that drives AF and HFpEF to coexist; 2) pharmacologic therapies that may attenuate the impact of AF in HFpEF; and 3) future directions in the management of this complex syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Thirty Years of Evidence on the Efficacy of Drug Treatments for Chronic Heart Failure With Reduced Ejection Fraction: A Network Meta-Analysis.

    Science.gov (United States)

    Burnett, Heather; Earley, Amy; Voors, Adriaan A; Senni, Michele; McMurray, John J V; Deschaseaux, Celine; Cope, Shannon

    2017-01-01

    Treatments that reduce mortality and morbidity in patients with heart failure with reduced ejection fraction, including angiotensin-converting enzyme inhibitors (ACEI), angiotensin receptor blockers (ARB), β-blockers (BB), mineralocorticoid receptor antagonists (MRA), and angiotensin receptor-neprilysin inhibitors (ARNI), have not been studied in a head-to-head fashion. This network meta-analysis aimed to compare the efficacy of these drugs and their combinations regarding all-cause mortality in patients with heart failure with reduced ejection fraction. A systematic literature review identified 57 randomized controlled trials published between 1987 and 2015, which were compared in terms of study and patient characteristics, baseline risk, outcome definitions, and the observed treatment effects. Despite differences identified in terms of study duration, New York Heart Association class, ejection fraction, and use of background digoxin, a network meta-analysis was considered feasible and all trials were analyzed simultaneously. The random-effects network meta-analysis suggested that the combination of ACEI+BB+MRA was associated with a 56% reduction in mortality versus placebo (hazard ratio 0.44, 95% credible interval 0.26-0.66); ARNI+BB+MRA was associated with the greatest reduction in all-cause mortality versus placebo (hazard ratio 0.37, 95% credible interval 0.19-0.65). A sensitivity analysis that did not account for background therapy suggested that ARNI monotherapy is more efficacious than ACEI or ARB monotherapy. The network meta-analysis showed that treatment with ACEI, ARB, BB, MRA, and ARNI and their combinations were better than the treatment with placebo in reducing all-cause mortality, with the exception of ARB monotherapy and ARB plus ACEI. The combination of ARNI+BB+MRA resulted in the greatest mortality reduction. © 2017 The Authors.

  9. Precision Medicine for Heart Failure with Preserved Ejection Fraction: An Overview.

    Science.gov (United States)

    Shah, Sanjiv J

    2017-06-01

    There are few proven therapies for heart failure with preserved ejection fraction (HFpEF). The lack of therapies, along with increased recognition of the disorder and its underlying pathophysiology, has led to the acknowledgement that HFpEF is heterogeneous and is not likely to respond to a one-size-fits-all approach. Thus, HFpEF is a prime candidate to benefit from a precision medicine approach. For this reason, we have assembled a compendium of papers on the topic of precision medicine in HFpEF in the Journal of Cardiovascular Translational Research. These papers cover a variety of topics relevant to precision medicine in HFpEF, including automated identification of HFpEF patients; machine learning, novel molecular approaches, genomics, and deep phenotyping of HFpEF; and clinical trial designs that can be used to advance precision medicine in HFpEF. In this introductory article, we provide an overview of precision medicine in HFpEF with the hope that the work described here and in the other papers in this special theme issue will stimulate investigators and clinicians to advance a more targeted approach to HFpEF classification and treatment.

  10. Rationale and design of the Karolinska-Rennes (KaRen) prospective study of dyssynchrony in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars H; Linde, Cecilia; Edner, Magnus; Lafitte, Stéphane; Persson, Hans; Bauer, Fabrice; Ohrvik, John; Ennezat, Pierre-Vladimir; Hage, Camilla; Löfman, Ida; Juilliere, Yves; Logeart, Damien; Derumeaux, Geneviève; Gueret, Pascal; Daubert, Jean-Claude

    2009-02-01

    Heart failure with preserved ejection fraction (HFPEF) is common but not well understood. Electrical dyssynchrony in systolic heart failure is harmful. Little is known about the prevalence and the prognostic impact of dyssynchrony in HFPEF. We have designed a prospective, multicenter, international, observational study to characterize HFPEF and to determine whether electrical or mechanical dyssynchrony affects prognosis. Patients presenting with acute heart failure (HF) will be screened so as to identify 400 patients with HFPEF. Inclusion criteria will be: acute presentation with Framingham criteria for HF, left ventricular ejection fraction>or=45%, brain natriuretic peptide (BNP)>100 pg/mL or NT-proBNP>300 pg/mL. Once stabilized, 4-8 weeks after the index presentation, patients will return and undergo questionnaires, serology, ECG, and Doppler echocardiography. Thereafter, patients will be followed for mortality and HF hospitalization every 6 months for at least 18 months. Sub-studies will focus on echocardiographic changes from the acute presentation to the stable condition and on exercise echocardiography, cardiopulmonary exercise testing, and serological markers. KaRen aims to characterize electrical and mechanical dyssynchrony and to assess its prognostic impact in HFPEF. The results might improve our understanding of HFPEF and generate answers to the question whether dyssynchrony could be a target for therapy in HFPEF.

  11. Ejection of Uranium Atoms from UO{sub 2} by Fission Fragments

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Goesta

    1964-02-15

    The numbers of uranium atoms ejected from the surface of sintered plates of UO{sub 2} by fission fragments have been measured over the fission density range 5x10{sup 15} to 7x10{sup 16} fissions/cm{sup 3}. The number of uranium atoms ejected per escaping fragment was about 9. The measurements were performed by irradiating the plates in vacuum and collecting a fraction of the uranium atoms ejected on catcher foils. The amount collected was determined by fission counting. Saturation of the amount collected, as reported by Rogers and Adam, was not observed. The numbers of uranium atoms ejected as knock-ons under the same experimental conditions have been calculated. The reasonably close agreement between the experimental and theoretical values indicates that, under the prevailing experimental conditions, mainly knock-ons are ejected. Other ejection mechanisms, e. g. evaporation of material in thermal spikes, are probably insignificant; this is in contrast to the usual interpretation of the ejection process. The mean range in UO{sub 2}, of fission products of mass number 140 was found to be 7.37 {+-} 0. 05 mg/cm{sup 2} by direct gamma spectrometric, determination of the fraction of {sup 140}La escaping from the surface of the plates.

  12. Sacubitril/Valsartan: A Review in Chronic Heart Failure with Reduced Ejection Fraction.

    Science.gov (United States)

    McCormack, Paul L

    2016-03-01

    Sacubitril/valsartan (Entresto™; LCZ696) is an orally administered supramolecular sodium salt complex of the neprilysin inhibitor prodrug sacubitril and the angiotensin receptor blocker (ARB) valsartan, which was recently approved in the US and the EU for the treatment of chronic heart failure (NYHA class II-IV) with reduced ejection fraction (HFrEF). In the large, randomized, double-blind, PARADIGM-HF trial, sacubitril/valsartan reduced the incidence of death from cardiovascular causes or first hospitalization for worsening heart failure (composite primary endpoint) significantly more than the angiotensin converting enzyme (ACE) inhibitor enalapril. Sacubitril/valsartan was also superior to enalapril in reducing death from any cause and in limiting the progression of heart failure. Sacubitril/valsartan was generally well tolerated, with no increase in life-threatening adverse events. Symptomatic hypotension was significantly more common with sacubitril/valsartan than with enalapril; the incidence of angio-oedema was low. Therefore, sacubitril/valsartan is a more effective replacement for an ACE inhibitor or an ARB in the treatment of HFrEF, and is likely to influence the basic approach to treatment.

  13. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    OpenAIRE

    Jonny Nordström; Tanja Kero; Hendrik Johannes Harms; Charles Widström; Frank A. Flachskampf; Jens Sörensen; Mark Lubberink

    2017-01-01

    BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility...

  14. Two-dimensional speckle-tracking strain echocardiography in long-term heart transplant patients: a study comparing deformation parameters and ejection fraction derived from echocardiography and multislice computed tomography.

    Science.gov (United States)

    Syeda, Bonni; Höfer, Peter; Pichler, Philipp; Vertesich, Markus; Bergler-Klein, Jutta; Roedler, Susanne; Mahr, Stephane; Goliasch, Georg; Zuckermann, Andreas; Binder, Thomas

    2011-07-01

    Longitudinal strain determined by speckle tracking is a sensitive parameter to detect systolic left ventricular dysfunction. In this study, we assessed regional and global longitudinal strain values in long-term heart transplants and compared deformation indices with ejection fraction as determined by transthoracic echocardiography (TTE) and multislice computed tomographic coronary angiography (MSCTA). TTE and MSCTA were prospectively performed in 31 transplant patients (10.6 years post-transplantation) and in 42 control subjects. Grey-scale apical views were recorded for speckle tracking (EchoPAC 7.0, GE) of the 16 segments of the left ventricle. The presence of coronary artery disease (CAD) was assessed by MSCTA. Strain analysis was performed in 1168 segments [496 in transplant patients (42.5%), 672 in control subjects (57.7%)]. Global longitudinal peak systolic strain was significantly lower in the transplant recipients than in the healthy population (-13.9 ± 4.2 vs. -17.4 ± 5.8%, PSimpsons method) was 60.7 ± 10.1%/60.2 ± 6.7% in transplant recipients vs. 64.7 ± 6.4%/63.0 ± 6.2% in the healthy population, P=ns. Even though 'healthy' heart transplants without CAD exhibit normal ejection fraction, deformation indices are reduced in this population when compared with control subjects. Our findings suggests that strain analysis is more sensitive than assessment of ejection fraction for the detection of abnormalities of systolic function.

  15. Cardiac I123-MIBG Correlates Better than Ejection Fraction with Symptoms Severity in Systolic Heart Failure

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Sandra M.; Moscavitch, Samuel D.; Carestiato, Larissa R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Felix, Renata M. [Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Rodrigues, Ronaldo C.; Messias, Leandro R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Azevedo, Jader C. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Nóbrega, Antonio Cláudio L.; Mesquita, Evandro Tinoco [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Mesquita, Claudio Tinoco, E-mail: ctinocom@cardiol.br [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil)

    2013-07-15

    The association of autonomic activation, left ventricular ejection fraction (LVEF) and heart failure functional class is poorly understood. Our aim was to correlate symptom severity with cardiac sympathetic activity, through iodine-123-metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy and with LVEF in systolic heart failure (HF) patients without previous beta-blocker treatment. Thirty-one patients with systolic HF, class I to IV of the New York Heart Association (NYHA), without previous beta-blocker treatment, were enrolled and submitted to {sup 123}I-MIBG scintigraphy and to radionuclide ventriculography for LVEF determination. The early and delayed heart/mediastinum (H/M) ratio and the washout rate (WR) were performed. According with symptom severity, patients were divided into group A, 13 patients in NYHA class I/II, and group B, 18 patients in NYHA class III/IV. Compared with group B patients, group A had a significantly higher LVEF (25% ± 12% in group B vs. 32% ± 7% in group A, p = 0.04). Group B early and delayed H/M ratios were lower than group A ratios (early H/M 1.49 ± 0.15 vs. 1.64 ± 0.14, p = 0.02; delayed H/M 1.39 ± 0.13 vs. 1.58 ± 0.16, p = 0.001, respectively). WR was significantly higher in group B (36% ± 17% vs. 30% ± 12%, p= 0.04). The variable that showed the best correlation with NYHA class was the delayed H/M ratio (r= -0.585; p=0.001), adjusted for age and sex. This study showed that cardiac {sup 123}I-MIBG correlates better than ejection fraction with symptom severity in systolic heart failure patients without previous beta-blocker treatment.

  16. Systolic Strain Abnormalities to Predict Hospital Readmission in Patients With Heart Failure and Normal Ejection Fraction

    Science.gov (United States)

    Borer, Steven M.; Kokkirala, Aravind; O'Sullivan, David M.; Silverman, David I.

    2011-01-01

    Background Despite intensive investigation, the pathogenesis of heart failure with normal ejection fraction (HFNEF) remains unclear. We hypothesized that subtle abnormalities of systolic function might play a role, and that abnormal systolic strain and strain rate would provide a marker for adverse outcomes. Methods Patients of new CHF and left ventricular ejection fraction > 50% were included. Exclusion criteria were recent myocardial infarction, severe valvular heart disease, severe left ventricular hypertrophy (septum >1.8 cm), or a technically insufficient echocardiogram. Average peak systolic strain and strain rate were measured using an off-line grey scale imaging technique. Systolic strain and strain rate for readmitted patients were compared with those who remained readmission-free. Results One hundred consecutive patients with a 1st admission for HFNEF from January 1, 2004 through December 31, 2007, inclusive, were analyzed. Fifty two patients were readmitted with a primary diagnosis of heart failure. Systolic strain and strain rates were reduced in both study groups compared to controls. However, systolic strain did not differ significantly between the two groups (-11.7% for those readmitted compared with -12.9% for those free from readmission, P = 0.198) and systolic strain rates also were similar (-1.05 s-1 versus -1.09 s-1, P = 0.545). E/e’ was significantly higher in readmitted patients compared with those who remained free from readmission (14.5 versus 11.0, P = 0.013). E/e’ (OR 1.189, 95% CI 1.026-1.378; P = 0.021) was found to be an independent predictor for HFNEF readmission. Conclusions Among patients with new onset HFNEF, SS and SR rates are reduced compared with patients free of HFNEF, but do not predict hospital readmission. Elevated E/e’ is a predictor of readmission in these patients. PMID:28352395

  17. Left ventricular performance at rest and during peak exercise in never-treated hypertensive female - an assessment with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Topuzovic, N.; Karner, I.; Rusic, A.; Krstonosic, B.

    2002-01-01

    Aim: The aim of this study was to investigate left ventricular performance and exercise tolerance in never-treated female hypertensive patients. Materials and Methods: Seventeen female patients with newly established, uncomplicated essential hypertension (aged 25 to 57 years) were evaluated with rest-stress radionuclide gated ventriculography, and were compared to 23 age-matched normotensive female volunteers. Results: Mean blood pressure was significantly higher in patients at rest and during exercise than in controls (121±13 vs. 89±7 mm Hg, and 143±11 vs. 122±9 mm Hg, respectively, p 2 , respectively, p<0.01), while ESV was similar in both groups. Ejection fraction (EF) at rest and stress did not differ significantly (54±10 vs. 55±8%, and 70±10 vs. 66±8%, respectively), but % rise in EF during exercise was significantly higher in patients. At rest and during exercise, there were no significant difference in peak ejection rate (PER) and time to PER (TPER) between patients and controls. Patients had similar peak filling rate (PFR) at rest (2.88±0.79 vs. 2.76±0.76 EDV/s) and during exercise (5.85±1.86 vs. 6.21±1.97 EDV/s), in addition to nonsignificant difference in time to PFR (at rest 143±62 vs. 146±42 ms at rest, and 97±20 vs. 91±19 ms during exercise). Conclusion: Female patients with newly diagnosed, never-treated hypertension have preserved maximal exercise performance, systolic function and diastolic function, but they have significant enlargement of EDV and elevated cardiac output during exercise

  18. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography.

    Science.gov (United States)

    Shahgaldi, Kambiz; Gudmundsson, Petri; Manouras, Aristomenis; Brodin, Lars-Ake; Winter, Reidar

    2009-08-25

    Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method. Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 +/- 3.7% and -0.2 +/- 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.

  19. Diagnosis of exercise-induced left bundle branch block at rest by scintigraphic phase analysis

    International Nuclear Information System (INIS)

    Schultz, D.A.; Wahl, R.L.; Juni, J.E.; Buda, A.J.; McMeekin, J.D.; Struble, L.R.; Tuscan, M.J.

    1986-01-01

    Accurate diagnosis of disease of the ventricular conducting system is essential for their appropriate therapy. Some conduction abnormalities, such as exercise-induced left bundle branch block (EX-LBBB), are not apparent on resting electrocardiograms. Phase analysis of rest and exercise radionuclide ventriculograms (RVG's) was used to compare four EX-LBBB patients with six normal controls. All patients had normal resting electrocardiograms, ejection fractions, and visually normal wall motion. First harmonic phase images were generated reflecting the timing of ventricular contraction. Dynamic phase displays were reviewed and graded in a blinded fashion by three independent experienced observers. Phase angle histograms of the right and left ventricle were determined for both resting and exercise images. The mean phase angle and standard deviation were also calculated for each ventricle. Visual grading of the resting phase images failed to show a significant difference between normal patients and patients with EX-LBBB. Quantitative analysis, however, revealed a significant difference in mean phase angle differences (LV-RV) in resting studies: 0.8 0 (+-1.9 0 SEM) in normal versus 9.3 0 (+-2.3 0 SEM) in EX-LBBB patients (P 0 in normals vs. 31.2 0 in EX-LBBB patients (P<0.001). Qualitative phase analysis of resting RVG's permits the diagnosis of cardiac conduction disease that is not apparent on the resting EKG and may result in better monitoring and treatment. (orig.)

  20. New strategies for heart failure with preserved ejection fraction: the importance of targeted therapies for heart failure phenotypes

    Science.gov (United States)

    Senni, Michele; Paulus, Walter J.; Gavazzi, Antonello; Fraser, Alan G.; Díez, Javier; Solomon, Scott D.; Smiseth, Otto A.; Guazzi, Marco; Lam, Carolyn S. P.; Maggioni, Aldo P.; Tschöpe, Carsten; Metra, Marco; Hummel, Scott L.; Edelmann, Frank; Ambrosio, Giuseppe; Stewart Coats, Andrew J.; Filippatos, Gerasimos S.; Gheorghiade, Mihai; Anker, Stefan D.; Levy, Daniel; Pfeffer, Marc A.; Stough, Wendy Gattis; Pieske, Burkert M.

    2014-01-01

    The management of heart failure with reduced ejection fraction (HF-REF) has improved significantly over the last two decades. In contrast, little or no progress has been made in identifying evidence-based, effective treatments for heart failure with preserved ejection fraction (HF-PEF). Despite the high prevalence, mortality, and cost of HF-PEF, large phase III international clinical trials investigating interventions to improve outcomes in HF-PEF have yielded disappointing results. Therefore, treatment of HF-PEF remains largely empiric, and almost no acknowledged standards exist. There is no single explanation for the negative results of past HF-PEF trials. Potential contributors include an incomplete understanding of HF-PEF pathophysiology, the heterogeneity of the patient population, inadequate diagnostic criteria, recruitment of patients without true heart failure or at early stages of the syndrome, poor matching of therapeutic mechanisms and primary pathophysiological processes, suboptimal study designs, or inadequate statistical power. Many novel agents are in various stages of research and development for potential use in patients with HF-PEF. To maximize the likelihood of identifying effective therapeutics for HF-PEF, lessons learned from the past decade of research should be applied to the design, conduct, and interpretation of future trials. This paper represents a synthesis of a workshop held in Bergamo, Italy, and it examines new and emerging therapies in the context of specific, targeted HF-PEF phenotypes where positive clinical benefit may be detected in clinical trials. Specific considerations related to patient and endpoint selection for future clinical trials design are also discussed. PMID:25104786

  1. Right ventricular systolic and diastolic function at rest in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Caglar, N.M.; Araki, Haruo; Taira, Yuji; Fukuyama, Takaya; Nakamura, Motoomi

    1985-01-01

    Right ventricular systolic and diastolic function was studied in patients with ischemic heart disease using equilibrium radionuclide ventriculography. In patients with inferior myocardial infarction and proximal right coronary lesions, the right ventricular ejection fraction (0.43+-0.06, n=10, mean+-SD) and peak filling rate (1.7+-0.4 EDV/sec) were lower than normals (0.57+-0.07 and 2.7+-0.4 EDV/sec, n=10, p<0.001, respectively). In these patients, the right ventricular time to peak filling rate was longer than in normals (225+-36 msec vs 136+-45 msec, p<0.001), while the left ventricular ejection fraction remained normal. In patients with inferior myocardial infarction and distal right coronary lesions, the right ventricular ejection fraction, peak filling rate and time to peak filling rate were not different from those in normals. Even in patients with proximal right coronary lesions, the right ventricular ejection fraction was normal unless they had an inferior myocardial infarction. A decreased left ventricular ejection fraction and abnormal motion of the ventricular septum did not affect the right ventricular ejection fraction. The present results suggest that patients with an inferior myocardial infarction and proximal right coronary lesion often develop right ventricular systolic and diastolic dysfunction. (author)

  2. Spironolactone in patients with heart failure and preserved ejection fraction.

    Science.gov (United States)

    Sánchez-Sánchez, C; Mendoza-Ruiz de Zuazu, H F; Formiga, F; Manzano, L; Ceresuela, L M; Carrera-Izquierdo, M; González Franco, Á; Epelde-Gonzalo, F; Cerqueiro-González, J M; Montero-Pérez-Barquero, M

    2015-01-01

    Aldosterone inhibitors have been shown to be beneficial for patients with systolic heart failure. However, the evidence from patients with heart failure and preserved ejection fraction (HFPEF) is limited. We evaluated the role of spironolactone in the prognosis of a cohort of patients with HFPEF. We analyzed the outcomes of patients hospitalized for HFPEF in 52 departments of internal medicine of the Spanish RICA registry according to those who did and did not take spironolactone. We recorded the posthospital mortality rate and readmissions at 1 year and performed a multivariate survival analysis. We included 1212 patients with HFPEF, with a mean age of 79 years (standard deviation, 7.9), (64.1% women), the majority of whom had hypertensive heart disease (50.7%). The patients treated with spironolactone, compared with those who were not treated with this diuretic, had a more advanced functional class, a higher number of readmissions (44.3 vs. 29.1%; p<0.001) and a higher rate in the combined variable of readmissions/mortality (39.0 vs. 29.0%; p=0.001). In the multivariate analysis, the administration of spironolactone was associated with an increase in readmissions (RR, 1.4; 95% CI, 1.16-1.78; p=0.001). For patients with HFPEF, the administration of spironolactone was associated with an increase in all-cause readmission, perhaps due to the higher rate of hyperpotassemia. Copyright © 2015. Published by Elsevier España, S.L.U.

  3. Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction. Comparison with three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Lipiec, P.; Wejner-Mik, P.; Krzeminska-Pakula, M.; Kapusta, A.; Kasprzak, J.D.; Kusmierek, J.; Plachcinska, A.; Szuminski, R.

    2008-01-01

    Parameters of left ventricular systolic function directly influence the management of patients with suspected coronary artery disease (CAD). Quantitative gated single-photon emission computed tomography (QGS; Cedars-Sinai Medical Center, Los Angeles, CA, USA) allows the computation of left ventricular ejection fraction (LVEF) from myocardial perfusion imaging studies which are frequently performed on patients with suspected CAD. Three-dimensional (3D) echocardiography is considered to be the echocardiographic ''gold standard'' for the quantification of LVEF. We sought to compare QGS with 3D echocardiography in the evaluation of EF in patients with suspected CAD. Ninety-one consecutive patients with suspected CAD, scheduled for coronary angiography, underwent rest electrocardiographic-gated technetium-99m methoxyisobutylisonitrile SPECT (G-SPECT) with measurement of LVEF by QGS and transthoracic 3D echocardiography with off-line measurement of LVEF (Tomtec 4D LV Analysis 1.1). The diagnosis of CAD was based on coronary angiography, performed on every patient. Nine patients were excluded from the analysis owing to unsuitability for 3D echocardiography (8 patients) or G-SPECT (1 patient). In the remaining group of 82 patients, 71 (87%) had significant CAD, 34 (42%) had a history of myocardial infarction, and 50 (61%) had perfusion defects at rest G-SPECT images. The mean LVEF measured by QGS and 3D echocardiography was 53±13% and 53±10%, respectively. The mean difference in LVEF between 3D echocardiography and QGS was 0.1±6.0% (P=0.87), and the correlation between the values obtained by both methods was high (r=0.88, P< 0.001). The largest discrepancies were observed in patients with small ventricular volumes. In patients undergoing diagnostic work-up for CAD, the measurement of LVEF by QGS algorithm provides high correlation and satisfactory agreement with the results of reference ultrasound method- 3D echocardiography. (author)

  4. Early Adoption of Sacubitril/Valsartan for Patients With Heart Failure With Reduced Ejection Fraction: Insights From Get With the Guidelines-Heart Failure (GWTG-HF).

    Science.gov (United States)

    Luo, Nancy; Fonarow, Gregg C; Lippmann, Steven J; Mi, Xiaojuan; Heidenreich, Paul A; Yancy, Clyde W; Greiner, Melissa A; Hammill, Bradley G; Hardy, N Chantelle; Turner, Stuart J; Laskey, Warren K; Curtis, Lesley H; Hernandez, Adrian F; Mentz, Robert J; O'Brien, Emily C

    2017-04-01

    The aim of this study was to assess the prevalence and variation in angiotensin receptor/neprilysin inhibitor (ARNI) prescription among a real-world population with heart failure with reduced ejection fraction (HFrEF). The U.S. Food and Drug Administration approved sacubitril/valsartan for patients with HFrEF in July 2015. Little is known about the early patterns of use of this novel therapy. The study included patients discharged alive from hospitals in Get With the Guidelines-Heart Failure (GWTG-HF), a registry of hospitalized patients with heart failure, between July 2015 and June 2016 who had documentation of whether ARNIs were prescribed at discharge. Patient and hospital characteristics were compared among patients with HFrEF (ejection fraction ≤40%) with and without ARNI prescription at discharge, excluding those with documented contraindications to ARNIs. To evaluate hospital variation, hospitals with at least 10 eligible hospitalizations during the study period were assessed. Of 21,078 patients hospitalized with HFrEF during the study period, 495 (2.3%) were prescribed ARNIs at discharge. Patients prescribed ARNIs were younger (median age 65 years vs. 70 years; p < 0.001), had lower ejection fractions (median 23% vs. 25%; p < 0.001), and had higher use of aldosterone antagonists (45% vs. 31%; p < 0.001) at discharge. At the 241 participating hospitals with 10 or more eligible admissions, 125 (52%) reported no discharge prescriptions of ARNIs. Approximately 2.3% of patients hospitalized for HFrEF in a national registry were prescribed ARNI therapy in the first 12 months following Food and Drug Administration approval. Further study is needed to identify and overcome barriers to implementing new evidence into practice, such as ARNI use among eligible patients with HFrEF. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Manouras Aristomenis

    2009-08-01

    Full Text Available Abstract Background Visual assessment of left ventricular ejection fraction (LVEF is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE and triplane echocardiography (TPE using quantitative real-time three-dimensional echocardiography (RT3DE as the reference method. Methods Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. Results There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively without any significant bias (-0.5 ± 3.7% and -0.2 ± 2.9% respectively. Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Conclusion Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.

  6. Receiver operating characteristics of diagnostic efficacy of resting left ventricular performance (evaluating with a non-imaging ECG gated scintillation detector - nuclear stethoscope)

    International Nuclear Information System (INIS)

    Kotlyarov, E.V.; Reba, R.C.; Lindsay, J.

    1983-01-01

    Receiver operating characteristic (ROC) analysis of left ventricular performance at rest was applied to evaluate diagnostic utility of non-imaging nuclear detector (''Nuclear Stethoscope''), for screening patients with coronary artery disease (CAD). Thirty-one patients without CAD and normal rest and stress radionuclide ventriculography (MUGA) were used as a control group. Another 62 patients with abnormal left ventricular reserve and segmental wall motion abnormalities at rest were also studied. All 93 patients were studied with the Nuclear Stethoscope (30 minutes after conventional MUGA testing) both in beat-to-beat and gated equilibrium modes. ROC analysis showed that along with ejection fraction, stroke and end-diastolic volumes, evaluation of the left ventricular filling phase has a great potential for the identification of patients with a segmental wall motion abnormality and, therefore, significant CAD

  7. Drug treatment effects on outcomes in heart failure with preserved ejection fraction: a systematic review and meta-analysis

    Science.gov (United States)

    Zheng, Sean Lee; Chan, Fiona T; Nabeebaccus, Adam A; Shah, Ajay M; McDonagh, Theresa; Okonko, Darlington O; Ayis, Salma

    2018-01-01

    Background Clinical drug trials in patients with heart failure and preserved ejection fraction have failed to demonstrate improvements in mortality. Methods We systematically searched Medline, Embase and the Cochrane Central Register of Controlled Trials for randomised controlled trials (RCT) assessing pharmacological treatments in patients with heart failure with left ventricular (LV) ejection fraction≥40% from January 1996 to May 2016. The primary efficacy outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, heart failure hospitalisation, exercise capacity (6-min walk distance, exercise duration, VO2 max), quality of life and biomarkers (B-type natriuretic peptide, N-terminal pro-B-type natriuretic peptide). Random-effects models were used to estimate pooled relative risks (RR) for the binary outcomes, and weighted mean differences for continuous outcomes, with 95% CI. Results We included data from 25 RCTs comprising data for 18101 patients. All-cause mortality was reduced with beta-blocker therapy compared with placebo (RR: 0.78, 95%CI 0.65 to 0.94, p=0.008). There was no effect seen with ACE inhibitors, aldosterone receptor blockers, mineralocorticoid receptor antagonists and other drug classes, compared with placebo. Similar results were observed for cardiovascular mortality. No single drug class reduced heart failure hospitalisation compared with placebo. Conclusion The efficacy of treatments in patients with heart failure and an LV ejection fraction≥40% differ depending on the type of therapy, with beta-blockers demonstrating reductions in all-cause and cardiovascular mortality. Further trials are warranted to confirm treatment effects of beta-blockers in this patient group. PMID:28780577

  8. Gallbladder ejection fraction using 99mTc-DISIDA scan in diabetic autonomic neuropathy

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; An, Jun Hyup; Yoo, Seok Dong

    2000-01-01

    We performed this study to evaluate the changes of gallbladder ejection fraction (GBEF) in diabetic patients with or without autonomic neuropathy. This study included 37 diabetic patients (25 women, 12 men, mean age 51 years) and 24 normal controls (10 women, 14 men, mean age 38 years). After intravenous injection of 185 MBq of 99m T c -DISIDA, serial anterior abdominal images were acquired before and after fatty meal. Regions of interest were applied on gallbladder and right hepatic lobe on 60 and 90 minute images to calculate GBEF. GBEF was significantly reduced in diabetes with autonomic neuropathy (43±12.3%) and without autonomic neuropathy (57.5±13.2%) compared with normal controls (68±11.6%, p 0.05). When 50.2% of GBEF was used as the criteria for diabetic autonomic neuropathy, the sensitivity and specificity were 80%, 76.5%, respectively. The area under receiver operating characteristic curve was 0.846. GBEF of diabetic patients with autonomic neuropathy was significantly reduced than that of diabetic patients without autonomic neuropathy.=20

  9. [Interest of tricuspid annular displacement (TAD) in evaluation of right ventricular ejection fraction].

    Science.gov (United States)

    Hugues, T; Ducreux, D; Bertora, D; Berthier, F; Lemoigne, F; Padovani, B; Gibelin, P

    2010-04-01

    The ultrasound assessment of RV structure and function is often sub-optimal. The range of excursions of the mitral or tricuspid annulus measured in millimetre by 2D or TM-mode in centimetre per second by DTI-mode echocardiography has been shown to reflect the systolic function of both ventricles. We studied a new technique based on a tissue tracking algorithm that is ultrasound beam angle independent for automated detection of tricuspid annular displacement (TAD) (QLAB, Philips Medical Imaging). Twenty-six patients (pts) referred for magnetic resonance imaging (MRI) and 44 control subjects underwent a complete transthoracic echocardiography. MRI of the right ventricular ejection fraction (RVEF) was correlated by linear regression with TAD. Sixteen pts (61.5%) exhibited right ventricular systolic dysfunction (MRI RVEFTAD (R(2)=0,65; pTAD TAD values exceeding this cut-off point (mean: 16.9+/-1.64mm; range: 13.3 to 24.8mm). Negative correlation was found between TAD and age (R(2)=0,36; pTAD with MRI RVEF. TAD is a simple, rapid, and non-invasive tool for right ventricular systolic function assessment.

  10. Prognostic importance of left ventricular mechanical dyssynchrony in heart failure with preserved ejection fraction

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Shah, Sanjiv J; Anand, Inder

    2017-01-01

    AIMS: Left ventricular mechanical dyssynchrony has been described in heart failure with preserved ejection fraction (HFpEF), but its prognostic significance is not known. METHODS AND RESULTS: Of 3445 patients with HFpEF enrolled in the Treatment of Preserved Cardiac Function Heart Failure...... models assessed the association of dyssynchrony with the composite outcome of cardiovascular death or heart failure hospitalization. Mean age was 70 ± 10 years, LVEF was 60 ± 8%, and QRS duration was 101 ± 27 ms. Worse dyssynchrony, reflected in SD T2P LS, was associated with wider QRS, prior myocardial...... with the composite outcome in unadjusted analysis [hazard ratio (HR) 1.04, 95% confidence interval (CI) 1.01-1.07; P = 0.021, per 10 ms increase], but not after adjusting for clinical characteristics, or after further adjustment for LVEF, AF, NYHA class, stroke, heart rate, creatinine, haematocrit, and QRS duration...

  11. Left ventricular markers of global dyssynchrony predict limited exercise capacity in heart failure, but not in patients with preserved ejection fraction

    Directory of Open Access Journals (Sweden)

    Bajraktari Gani

    2012-09-01

    Full Text Available Abstract Background The aim of this study was to prospectively examine echocardiographic parameters that correlate and predict functional capacity assessed by 6 min walk test (6-MWT in patients with heart failure (HF, irrespective of ejection fraction (EF. Methods In 147 HF patients (mean age 61 ± 11 years, 50.3% male, a 6-MWT and an echo-Doppler study were performed in the same day. Global LV dyssynchrony was indirectly assessed by total isovolumic time - t-IVT [in s/min; calculated as: 60 – (total ejection time + total filling time], and Tei index (t-IVT/ejection time. Patients were divided into two groups based on the 6-MWT distance (Group I: ≤300 m and Group II: >300 m, and also in two groups according to EF (Group A: LVEF ≥ 45% and Group B: LVEF  Results In the cohort of patients as a whole, the 6-MWT correlated with t-IVT (r = −0.49, p  Conclusion In patients with HF, the limited exercise capacity, assessed by 6-MWT, is related mostly to severity of global LV dyssynchrony, more than EF or raised filling pressures. The lack of exercise predictors in HFpEF reflects its multifactorial pathophysiology.

  12. Heart failure with preserved ejection fraction: mechanisms, clinical features, and therapies.

    Science.gov (United States)

    Sharma, Kavita; Kass, David A

    2014-06-20

    The clinical syndrome comprising heart failure (HF) symptoms but with a left ventricular ejection fraction (EF) that is not diminished, eg, HF with preserved EF, is increasingly the predominant form of HF in the developed world, and soon to reach epidemic proportions. It remains among the most challenging of clinical syndromes for the practicing clinician and scientist alike, with a multitude of proposed mechanisms involving the heart and other organs and complex interplay with common comorbidities. Importantly, its morbidity and mortality are on par with HF with reduced EF, and as the list of failed treatments continues to grow, HF with preserved EF clearly represents a major unmet medical need. The field is greatly in need of a more unified approach to its definition and view of the syndrome that engages integrative and reserve pathophysiology beyond that related to the heart alone. We need to reflect on prior treatment failures and the message this is providing, and redirect our approaches likely with a paradigm shift in how the disease is viewed. Success will require interactions between clinicians, translational researchers, and basic physiologists. Here, we review recent translational and clinical research into HF with preserved EF and give perspectives on its evolving demographics and epidemiology, the role of multiorgan deficiencies, potential mechanisms that involve the heart and other organs, clinical trials, and future directions. © 2014 American Heart Association, Inc.

  13. A comparison of resting images from two myocardial perfusion tracers

    International Nuclear Information System (INIS)

    Anagnostopoulos, C.; Laney, R.; Pennell, D.; Proukakis, H.; Underwood, R.

    1995-01-01

    We have compared stress-redistribution and delayed rest thallium-201 with rest technetium-99m methoxyisobutylisonitrile (MIBI) tomograms in order to compare the tracers for the assessment of myocardial viability and to validate a rapid protocol combining the two tracers. We studied 30 consecutive patients with known or suspected coronary artery disease [group 1: 16 with normal left ventricular function, mean left ventricular ejection fraction (LVEF) 55%, SD 6%; group 2: 14 with abnormal function, mean LVEF 28%, SD 8%]. 201 Tl was injected during infusion of adenosine followed by acquisition of conventional stress and redistribution tomograms. On a separate day, 201 Tl was injected at rest with imaging 4 h later. 99m Tc-MIBI was then given at rest and imaging was performed. Three images were compared: redistribution 201 Tl, rest 201 Tl, and rest 99m Tc-MIBI. Tracer activity was classified visually and quantitatively in nine segments and segments with>50% activity were defined as containing clinically significant viable myocardium. Mean global tracer uptake as a percentage of maximum was similar in group 1 (rest 201 Tl 69%±12%, redistribution 201 Tl 69%±15%, rest 99m Tc-MIBI 70%±13%), but in group 2 mean tracer uptake was significantly greater in the rest 201 Tl images (59%±16%) than in redistribution 201 Tl images (53%±17%) or rest 99m Tc-MIBI images (53%±19%). Overall agreement for regional uptake score was excellent (κ from 0.79 to 0.84), although there were a significant number of segments with less uptake shown by redistribution 201 Tl and by rest 99m Tc-MIBI than by rest 201 Tl in group 2. The number of segments with significant viable myocardium in group 1 was very similar between the three images but in group 2 rest 201 Tl identified significantly more segments as viable than the other images. (orig./MG) (orig.). With 1 fig., 7 tabs

  14. Acute heart failure with mid-range left ventricular ejection fraction: clinical profile, in-hospital management, and short-term outcome.

    Science.gov (United States)

    Farmakis, Dimitrios; Simitsis, Panagiotis; Bistola, Vasiliki; Triposkiadis, Filippos; Ikonomidis, Ignatios; Katsanos, Spyridon; Bakosis, George; Hatziagelaki, Erifili; Lekakis, John; Mebazaa, Alexandre; Parissis, John

    2017-05-01

    Heart failure with mid-range left ventricular ejection fraction (HFmrEF) is a poorly characterized population as it has been studied either in the context of HF with reduced (HFrEF) or preserved (HFpEF) left ventricular ejection fraction (LVEF) depending on applied LVEF cutoffs. We sought to investigate the clinical profile, in-hospital management, and short-term outcome of HFmrEF patients in comparison with those with HFrEF or HFpEF in a large acute HF cohort. The Acute Heart Failure Global Registry of Standard Treatment (ALARM-HF) included 4953 patients hospitalized for HF in nine countries in Europe, Latin America, and Australia. Baseline characteristics, clinical presentation, in-hospital therapies, and short-term mortality (all-cause in-hospital or 30-day mortality, whichever first) were compared among HFrEF (LVEF chronic renal disease (p = 0.003), more hospitalizations for acute coronary syndrome (p < 0.001), or infection (p = 0.003), and were more frequently treated with intravenous vasodilators compared to HFrEF or HFpEF. Adjusted short-term mortality in HFmrEF was lower than HFrEF [hazard ratio (HR) = 0.635 (0.419, 0.963), p = 0.033] but similar to HFpEF [HR = 1.026 (0.605, 1.741), p = 0.923]. Hospitalized HFmrEF patients represent a demographically and clinically diverse group with many intermediate features compared to HFrEF and HFpEF and carry a lower risk of short-term mortality than HFrEF but a similar risk with HFpEF.

  15. Technetium-99m sestamibi imaging to predict left ventricular ejection fraction outcome after revascularisation in patients with chronic coronary artery disease and left ventricular dysfunction: comparison between baseline and nitrate-enhanced imaging

    International Nuclear Information System (INIS)

    Sciagra, R.; Pupi, A.; Leoncini, M.; Dabizzi, R.P.; Marcucci, G.

    2001-01-01

    Acceptance of technetium-99m sestamibi as a tracer of myocardial viability is growing, particularly when nitrate-enhanced imaging is used. However, few data are available on the ability of 99m Tc-sestamibi to predict the evolution of global left ventricular ejection fraction (EF). The aim of this study was to examine the ability of resting and nitrate 99m Tc-sestamibi single-photon emission tomography (SPET) to predict EF changes after revascularisation in patients who have chronic coronary artery disease with left ventricular dysfunction. Using baseline resting and nitrate 99m Tc-sestamibi SPET, we studied 61 patients scheduled for revascularisation because of left ventricular dysfunction. EF was estimated using two-dimensional echocardiography before and after the intervention. A post-revascularisation improvement of ≥5 EF units was defined as significant. Using a 13-segment model, 99m Tc-sestamibi activity was quantified and the nitrate-induced activity changes calculated. Three different criteria for detecting viability (defined as post-revascularisation reversible dysfunction) in asynergic segments were compared: (1) resting 99m Tc-sestamibi activity ≥60%; (2) nitrate 99m Tc-sestamibi activity ≥65%; and (3) nitrate-induced increase >+10% or nitrate-induced increase ≤+10% and nitrate activity ≥65%. EF increased significantly in 32 patients. The number of viable asynergic segments was significantly higher in these patients than in the remaining 29 subjects, and the difference was greater (P 99m Tc-sestamibi SPET appears able to predict the evolution of global left ventricular EF after revascularisation, thereby confirming the value of 99m Tc-sestamibi as a tracer of myocardial viability. The combination of baseline resting and nitrate imaging seems to significantly improve the diagnostic accuracy of 99m Tc-sestamibi SPET for this particular purpose. (orig.)

  16. Urinary Proteomics Pilot Study for Biomarker Discovery and Diagnosis in Heart Failure with Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Rossing, Kasper; Bosselmann, Helle Skovmand; Gustafsson, Finn

    2016-01-01

    and Results Urine samples were analyzed by on-line capillary electrophoresis coupled to electrospray ionization micro time-of-flight mass spectrometry (CE-MS) to generate individual urinary proteome profiles. In an initial biomarker discovery cohort, analysis of urinary proteome profiles from 33 HFr......Background Biomarker discovery and new insights into the pathophysiology of heart failure with reduced ejection fraction (HFrEF) may emerge from recent advances in high-throughput urinary proteomics. This could lead to improved diagnosis, risk stratification and management of HFrEF. Methods.......6%) in individuals with diastolic left ventricular dysfunction (N = 176). The HFrEF-related peptide biomarkers mainly included fragments of fibrillar type I and III collagen but also, e.g., of fibrinogen beta and alpha-1-antitrypsin. Conclusion CE-MS based urine proteome analysis served as a sensitive tool...

  17. Rationale, Design, and Methodology of the APOLLON trial: A comPrehensive, ObservationaL registry of heart faiLure with midrange and preserved ejectiON fraction.

    Science.gov (United States)

    Özlek, Bülent; Özlek, Eda; Çelik, Oğuzhan; Çil, Cem; Doğan, Volkan; Tekinalp, Mehmet; Zencirkıran Ağuş, Hicaz; Kahraman, Serkan; Ösken, Altuğ; Rencüzoğulları, İbrahim; Tanık, Veysel Ozan; Bekar, Lütfü; Çakır, Mustafa Ozan; Kaya, Bedri Caner; Tibilli, Hakan; Çelik, Yunus; Başaran, Özcan; Mert, Kadir Uğur; Sevinç, Samet; Demirci, Erkan; Dondurmacı, Engin; Biteker, Murat

    2018-05-01

    Although almost half of chronic heart failure (HF) patients have mid-range (HFmrEF) and preserved left-ventricular ejection fraction (HFpEF), no studies have been carried out with these patients in our country. This study aims to determine the demographic characteristics and current status of the clinical background of HFmrEF and HFpEF patients in a multicenter trial. A comPrehensive, ObservationaL registry of heart faiLure with mid range and preserved ejectiON fraction (APOLLON) trial will be an observational, multicenter, and noninterventional study conducted in Turkey. The study population will include 1065 patients from 12 sites in Turkey. All data will be collected at one point in time and the current clinical practice will be evaluated (ClinicalTrials.gov number NCT03026114). We will enroll all consecutive patients admitted to the cardiology clinics who were at least 18 years of age and had New York Heart Association class II, III, or IV HF, elevated brain natriuretic peptide levels within the last 30 days, and an left ventricular ejection fraction (LVEF) of at least 40%. Patients fulfilling the exclusion criteria will not be included in the study. Patients will be stratified into two categories according to LVEF: mid-range EF (HFmrEF, LVEF 40%-49%) and preserved EF (HFpEF, LVEF ≥50%). Regional quota sampling will be performed to ensure that the sample was representative of the Turkish population. Demographic, lifestyle, medical, and therapeutic data will be collected by this specific survey. The APOLLON trial will be the largest and most comprehensive study in Turkey evaluating HF patients with a LVEF ≥40% and will also be the first study to specifically analyze the recently designated HFmrEF category.

  18. Reproducibility of gallbladder ejection fraction measured by fatty meal cholescintigraphy

    International Nuclear Information System (INIS)

    Al-Muqbel, Kusai M.; Hani, M. N. Hani; Elheis, M. A.; Al-Omari, M. H.

    2010-01-01

    There are conflicting data in the literature regarding the reproducibility of the gallbladder ejection fraction (GBEF) measured by fatty meal cholescintigraphy (CS). We aimed to test the reproducibility of GBEF measured by fatty meal CS. Thirty-five subjects (25 healthy volunteers and 10 patients with chronic abdominal pain) underwent fatty meal CS twice in order to measure GBEF1 and GBEF2. The healthy volunteers underwent a repeat scan within 1-13 months from the first scan. The patients underwent a repeat scan within 1-4 years from the first scan and were not found to have chronic acalculous cholecystitis (CAC). Our standard fatty meal was composed of a 60-g Snickers chocolate bar and 200 ml full-fat yogurt. The mean ± SD values for GBEF1 and GBEF2 were 52±17% and 52±16%, respectively. There was a direct linear correlation between the values of GBEF1 and GBEF2 for the subjects, with a correlation coefficient of 0.509 (p=0.002). Subgroup data analysis of the volunteer group showed that there was significant linear correlation between volunteer values of GBEF1 and GBEF2, with a correlation coefficient of 0.473 (p=0.017). Subgroup data analysis of the non-CAC patient group showed no significant correlation between patient values of GBEF1 and GBEF2, likely due to limited sample size. This study showed that fatty meal CS is a reliable test in gallbladder motility evaluation and that GBEF measured by fatty meal CS is reproducible

  19. Reproducibility of gallbladder ejection fraction measured by fatty meal cholescintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Muqbel, Kusai M.; Hani, M. N. Hani; Elheis, M. A.; Al-Omari, M. H. [School of Medicine, Jordan University of Science and Technology, Irbid (Jordan)

    2010-12-15

    There are conflicting data in the literature regarding the reproducibility of the gallbladder ejection fraction (GBEF) measured by fatty meal cholescintigraphy (CS). We aimed to test the reproducibility of GBEF measured by fatty meal CS. Thirty-five subjects (25 healthy volunteers and 10 patients with chronic abdominal pain) underwent fatty meal CS twice in order to measure GBEF1 and GBEF2. The healthy volunteers underwent a repeat scan within 1-13 months from the first scan. The patients underwent a repeat scan within 1-4 years from the first scan and were not found to have chronic acalculous cholecystitis (CAC). Our standard fatty meal was composed of a 60-g Snickers chocolate bar and 200 ml full-fat yogurt. The mean {+-} SD values for GBEF1 and GBEF2 were 52{+-}17% and 52{+-}16%, respectively. There was a direct linear correlation between the values of GBEF1 and GBEF2 for the subjects, with a correlation coefficient of 0.509 (p=0.002). Subgroup data analysis of the volunteer group showed that there was significant linear correlation between volunteer values of GBEF1 and GBEF2, with a correlation coefficient of 0.473 (p=0.017). Subgroup data analysis of the non-CAC patient group showed no significant correlation between patient values of GBEF1 and GBEF2, likely due to limited sample size. This study showed that fatty meal CS is a reliable test in gallbladder motility evaluation and that GBEF measured by fatty meal CS is reproducible

  20. Outcomes of de novo and acute decompensated heart failure patients according to ejection fraction.

    Science.gov (United States)

    Choi, Ki Hong; Lee, Ga Yeon; Choi, Jin-Oh; Jeon, Eun-Seok; Lee, Hae-Young; Cho, Hyun-Jai; Lee, Sang Eun; Kim, Min-Seok; Kim, Jae-Joong; Hwang, Kyung-Kuk; Chae, Shung Chull; Baek, Sang Hong; Kang, Seok-Min; Choi, Dong-Ju; Yoo, Byung-Su; Kim, Kye Hun; Park, Hyun-Young; Cho, Myeong-Chan; Oh, Byung-Hee

    2018-03-01

    There are conflicting results among previous studies regarding the prognosis of heart failure with preserved ejection fraction (HFpEF) compared with heart failure with reduced ejection fraction (HFrEF). This study aimed to compare the outcomes of patients with de novo acute heart failure (AHF) or acute decompensated HF (ADHF) according to HFpEF (EF≥50%), or HFrEF (EF<40%) and to define the prognosis of patients with HF with mid-range EF (HFmrEF, 40≤EF<50%). Between March 2011 and February 2014, 5625 consecutive patients with AHF were recruited from 10 university hospitals. A total of 5414 (96.2%) patients with EF data were enrolled, which consisted of 2867 (53.0%) patients with de novo and 2547 (47.0%) with ADHF. Each of the enrolled group was stratified by EF. In de novo, all-cause death rates were not significantly different between HFpEF and HFrEF (HFpEF vs HFrEF, 206/744 (27.7%) vs 438/1631 (26.9%), HR adj 1.15, 95% CI 0.96 to 1.38, p=0.14). However, among patients with ADHF, HFrEF had a significantly higher mortality rate compared with HFpEF (HFpEF vs HFrEF, 245/613 (40.0%) vs 694/1551 (44.7%), HR adj 1.25, 95% CI 1.06 to 1.47, p=0.007). Also, in ADHF, HFmrEF was associated with a significantly lower mortality rate within 1 year compared with HFrEF (HFmrEF vs HFrEF, 88/383 (23.0%) vs 430/1551 (27.7%), HR adj 1.31, 95% CI 1.03 to 1.65, p=0.03), but a significantly higher mortality rate after 1 year compared with HFpEF (HFmrEF vs HFpEF, 83/295 (28.1%) vs 101/469 (21.5%), HR adj 0.70, 95% CI 0.52 to 0.96, p=0.02). HFpEF may indicate a better prognosis compared with HFrEF in ADHF, but not in de novo AHF. For patients with ADHF, the prognosis associated with HFmrEF was similar to that of HFpEF within the first year following hospitalisation and similar to HFrEF 1  year after hospitalisation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted

  1. Drug treatment effects on outcomes in heart failure with preserved ejection fraction: a systematic review and meta-analysis.

    Science.gov (United States)

    Zheng, Sean Lee; Chan, Fiona T; Nabeebaccus, Adam A; Shah, Ajay M; McDonagh, Theresa; Okonko, Darlington O; Ayis, Salma

    2018-03-01

    Clinical drug trials in patients with heart failure and preserved ejection fraction have failed to demonstrate improvements in mortality. We systematically searched Medline, Embase and the Cochrane Central Register of Controlled Trials for randomised controlled trials (RCT) assessing pharmacological treatments in patients with heart failure with left ventricular (LV) ejection fraction≥40% from January 1996 to May 2016. The primary efficacy outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, heart failure hospitalisation, exercise capacity (6-min walk distance, exercise duration, VO 2 max), quality of life and biomarkers (B-type natriuretic peptide, N-terminal pro-B-type natriuretic peptide). Random-effects models were used to estimate pooled relative risks (RR) for the binary outcomes, and weighted mean differences for continuous outcomes, with 95% CI. We included data from 25 RCTs comprising data for 18101 patients. All-cause mortality was reduced with beta-blocker therapy compared with placebo (RR: 0.78, 95%CI 0.65 to 0.94, p=0.008). There was no effect seen with ACE inhibitors, aldosterone receptor blockers, mineralocorticoid receptor antagonists and other drug classes, compared with placebo. Similar results were observed for cardiovascular mortality. No single drug class reduced heart failure hospitalisation compared with placebo. The efficacy of treatments in patients with heart failure and an LV ejection fraction≥40% differ depending on the type of therapy, with beta-blockers demonstrating reductions in all-cause and cardiovascular mortality. Further trials are warranted to confirm treatment effects of beta-blockers in this patient group. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Lie, S.P.; Simoons, M.L.; Hoek, C.; Gerbrands, J.J.; Wijns, W.; Bakker, W.H.; Kooij, P.P.M.

    1983-01-01

    A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r=0.98). The authors conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography

  3. Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies

    International Nuclear Information System (INIS)

    Montelatici, Giulia; Sciagra, Roberto; Passeri, Alessandro; Dona, Manjola; Pupi, Alberto

    2008-01-01

    Conflicting data exist about the difference between 8- and 16-frame gated single-photon emission computed tomography (SPECT) left ventricular volumes and ejection fraction (EF); moreover, the influence of framing on detection of stress-induced functional changes is unknown. In 133 patients, two separate gated SPECT studies, one with 8 and one with 16 frames, were simultaneously acquired during a single gantry orbit using dedicated software. In 33 of 133 patients, two additional studies (with 8 and 16 frames, respectively) were acquired using arrhythmia rejection. Left ventricular EF and volumes were calculated using the QGS software. Stress-induced ischemia was identified on summed perfusion images. Arrhythmia-rejection did not influence volumes and EF independently of framing rate. Using data without arrhythmia-rejection, there was a significant difference in volumes and EF between 8 and 16 frames both in resting and post-stress gated SPECT. However, the difference was small: 2.6% for resting and 2.8% for post-stress EF. Both using 8 and 16 frames, there were significantly larger volumes and lower EF in patients with than without stress-induced ischemia. A stress-induced decrease >5 EF units was observed in 26 of 133 patients using 8 and in 23 of 133 using 16 frames, respectively, with finding agreement in 19 patients. Comparing two simultaneously acquired studies, the use of 16 instead of 8 frames has minor and predictable influence on functional data. Furthermore, there are no differences in the detection of stress-induced functional changes. The advantage of 16 over 8 frames in the daily clinical practice appears questionable. (orig.)

  4. Radionuclide assessment of left ventricular function in patients requiring intraoperative balloon pump assistance

    International Nuclear Information System (INIS)

    Davies, R.A.; Laks, H.; Wackers, F.J.; Berger, H.J.; Williams, B.; Hammond, G.L.; Geha, A.S.; Gottschalk, A.; Zaret, B.L.

    1982-01-01

    Twenty-three surviving patients who were weaned from cardiopulmonary bypass with intraaortic balloon pump assistance returned for follow-up radionuclide left ventricular (LV) function and thallium 201 perfusion studies at a mean of 23 +/- 3 months following operation. It was found that despite profound intraoperative myocardial depression requiring intraaortic balloon assistance, 13 patients had no change (within 10%) in the resting LV ejection fraction compared with the preoperative measurement. Among all 23 patients, there was no difference between mean (+/- standard error of the mean) preoperative and postoperative resting LV ejection fraction (48 +/- 4 vs 46 +/- 4%, p . not significant [NS]). Only 11 patients had perioperative myocardial infarction documented by new Q waves in the electrocardiogram, by elevation of creatine kinase-MB fraction, or by defects on thallium 201 imaging not explained by documented myocardial infarction before operation. Overall, postoperative resting LV ejection fraction was not different from the preoperative value in patients with perioperative myocardial infarction (44 +/- 7 vs 47 +/- 5%, p . NS). Postoperative resting LV ejection fraction rose by greater than 10% compared with preoperative values in 4 patients (3 with aortic valve replacement), remained within the 10% limit in 9 patients, and fell by greater than 10% in 10 patients (7 with perioperative myocardial infarction). Only 4 out of 16 patients studied at follow-up with exercise radionuclide studies demonstrated a normal LV response to exercise (greater than 5% increase in LV ejection fraction). Thus, among survivors requiring intraaortic balloon pump assistance for weaning from cardiopulmonary bypass, LV performance at rest is frequently preserved. In addition, 11 of the 23 patients had evidence of perioperative myocardial infarction, indicating a component of reversible intraoperative LV dysfunction

  5. Hemodynamic and radionuclide effects of acute captopril therapy for heart failure: changes in left and right ventricular volumes and function at rest and during exercise

    International Nuclear Information System (INIS)

    Massie, B.; Kramer, B.L.; Topic, N.; Henderson, S.G.

    1982-01-01

    Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responses at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured

  6. Copeptin in patients with heart failure and preserved ejection fraction: a report from the prospective KaRen-study.

    Science.gov (United States)

    Hage, Camilla; Lund, Lars H; Donal, Erwan; Daubert, Jean-Claude; Linde, Cecilia; Mellbin, Linda

    2015-01-01

    Underlying mechanisms of heart failure (HF) with preserved ejection fraction (HFPEF) remain unknown. We explored copeptin, a biomarker of the arginine vasopressin system, hypothesising that copeptin in HFPEF is elevated, associated with diastolic dysfunction and N-terminal pro-brain natriuretic peptide (NT-proBNP) and predictive of HF hospitalisation and mortality. In a prospective observational substudy of the The Karolinska Rennes (KaRen) 86 patients with symptoms of acute HF and ejection fraction (EF) ≥45% were enrolled. After 4-8 weeks, blood sampling and echocardiography was performed. Plasma-copeptin was analysed in 86 patients and 62 healthy controls. Patients were followed in median 579 days (quartile 1; quartile 3 (Q1;Q3) 276;1178) regarding the composite end point all-cause mortality or HF hospitalisation. The patients with HFPEF had higher copeptin levels, median 13.56 pmol/L (Q1;Q3 8.56;20.55) than controls 5.98 pmol/L (4.15;9.42; p<0.001). Diastolic dysfunction, assessable in 75/86 patients, was present in 45 and absent in 30 patients. Copeptin did not differ regarding diastolic dysfunction and did not correlate with cardiac function but with NT-proBNP (r=0.223; p value=0.040). In univariate Cox regression analysis log copeptin predicted the composite end point (HR 1.56 (95% CI 1.03 to 2.38; p value=0.037)) but not after adjusting for NT-proBNP (HR 1.39 (95% CI 0.91 to 2.12; p value=0.125)). In the present patients with HFPEF, copeptin is elevated, correlates with NT-proBNP but not markers of diastolic dysfunction, and has prognostic implications, however blunted after adjustment for NT-proBNP. The HFPEF pathophysiology may be better reflected by markers of neurohormonal activation than by diastolic dysfunction. ClinicalTrials.gov NCT00774709.

  7. Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary-artery disease

    International Nuclear Information System (INIS)

    Borer, J.S.; Bacharach, S.L.; Green, M.V.; Kent, K.M.; Epstein, S.E.; Johnston, G.S.

    1977-01-01

    Although coronary angiography defines regions of potential ischemia in patients with coronary-artery disease, accurate assessment of the presence and functional importance of ischemia requires appraisal of regional and global left ventricular function during stress. To perform such assessment, we developed a noninvasive real-time radionuclide cineangiographic procedure permitting continuous monitoring and analysis of left ventricular function during exercise. In 11 patients with coronary disease who had normal regional and global ventricular function at rest, new regions of dysfunction developed during exercise (P less than 0.001), and in 10, global ejection fraction dropped 7 to 47 percent. Fourteen age-matched normal subjects were studied; during exercise none had regional dysfunction, and each increased global ejection fraction (average increase, 23 +- 3 percent [+-S.E.], P less than 0.001 as compared with patients with coronary disease). Radionuclide cineangiography during exercise permits accurate assessment of the presence and functional severity of ischemic heart disease

  8. Accuracy of diagnosis of coronary artery disease by radionuclide management of left ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Jones, R.H.; McEwan, P.; Newman, G.E.; Port, S.; Rerych, S.K.; Scholz, P.M.; Upton, M.T.; Peter, C.A.; Austin, E.H.; Leong, K.H.; Gibbons, R.J.; Cobb, F.R.; Coleman, R.E.; Sabiston, D.C. Jr.

    1981-01-01

    Rest and exercise radionuclide angiocardiographic measurements of left ventricular function were obtained in 496 patients who underwent cardiac catheterization for chest pain. Two hundred forty-eight of these patients also had an exercise treadmill test. An ejection fraction less than 50% was the abnormality of resting left ventricular function that provided the greatest diagnostic information. In patients with normal resting left ventricular function, exercise abnormalities that were optimal for diagnosis of coronary artery disease were an injection fraction at least 6% less than predicted, an increase greater than 20 ml in end-systolic volume and the appearance of an exercise-induced wall motion abnormality. The sensitivity and specificity of the test were lower in patients who were taking propranolol at the time of study and in patients who failed to achieve an adequate exercise end point. In the 387 patients with an optimal study, the test had a sensitivity of 90% and a specificity of 58%. Radionuclide angiocardiography was more sensitive and less specific than the exercise treadmill test. The high degree of sensitivity of the radionuclide test suggests that it is most appropriately applied to patient groups with a high prevalence of disease, including those considered for cardiac catheterization

  9. Cardiosphere-Derived Cells Reverse Heart Failure With Preserved Ejection Fraction in Rats by Decreasing Fibrosis and Inflammation

    Directory of Open Access Journals (Sweden)

    Romain Gallet, MD

    2016-01-01

    Full Text Available The pathogenesis of heart failure with a preserved ejection fraction (HFpEF is unclear. Myocardial fibrosis, inflammation, and cardiac hypertrophy have been suggested to contribute to the pathogenesis of HFpEF. Cardiosphere-derived cells (CDCs are heart-derived cell products with antifibrotic and anti-inflammatory properties. This study tested whether rat CDCs were sufficient to decrease manifestations of HFpEF in hypertensive rats. Starting at 7 weeks of age, Dahl salt-sensitive rats were fed a high-salt diet for 6 to 7 weeks and randomized to receive intracoronary CDCs or placebo. Dahl rats fed normal chow served as controls. High-salt rats developed hypertension, left ventricular (LV hypertrophy, and diastolic dysfunction, without impairment of ejection fraction. Four weeks after treatment, diastolic dysfunction resolved in CDC-treated rats but not in placebo. The improved LV relaxation was associated with lower LV end-diastolic pressure, decreased lung congestion, and enhanced survival in CDC-treated rats. Histology and echocardiography revealed no decrease in cardiac hypertrophy after CDC treatment, consistent with the finding of sustained, equally-elevated blood pressure in CDC- and placebo-treated rats. Nevertheless, CDC treatment decreased LV fibrosis and inflammatory infiltrates. Serum inflammatory cytokines were likewise decreased after CDC treatment. Whole-transcriptome analysis revealed that CDCs reversed changes in numerous transcripts associated with HFpEF, including many involved in inflammation and/or fibrosis. These studies suggest that CDCs normalized LV relaxation and LV diastolic pressure while improving survival in a rat model of HFpEF. The benefits of CDCs occurred despite persistent hypertension and cardiac hypertrophy. By selectively reversing inflammation and fibrosis, CDCs may be beneficial in the treatment of HFpEF.

  10. Left ventricular performance during psychological stress

    International Nuclear Information System (INIS)

    Young, D.Z.; Massachusetts General Hospital, Boston; Dimsdale, J.E.; Moore, R.H.; Barlai-Kovach, M.; Newell, J.B.; McKusick, K.A.; Boucher, C.A.; Fifer, M.A.; Strauss, H.W.

    1989-01-01

    Left ventricular ejection fraction, systolic blood pressure and plasma norepinephrine were measured in six normotensive and six mildly hypertensive subjects during rest and psychological stress. Compared with rest, 8 of the 12 subjects developed significant changes in ejection fraction (increase in 6, decrease in 2); 10 of 12 subjects developed significant elevations of plasma norepinephrine; and all developed significant increases in systolic blood pressure. When the stress effects were examined for the total group, as opposed to within subjects, there were significant increases in plasma norepinephrine and systolic blood pressure but, interestingly, mean ejection fraction and stroke volume remained unchanged, implying stress led to increased left ventricular contractility. (orig.)

  11. Device therapy in heart failure with reduced ejection fraction-cardiac resynchronization therapy and more.

    Science.gov (United States)

    Duncker, D; Veltmann, C

    2018-05-09

    In patients with heart failure with reduced ejection fraction (HFrEF), optimal medical treatment includes beta-blockers, ACE inhibitors/angiotensinreceptor-neprilysin inhibitors (ARNI), mineralocorticoid receptor antagonists, and ivabradine when indicated. In device therapy of HFrEF, implantable cardioverter-defibrillators and cardiac resynchronization therapy (CRT) have been established for many years. CRT is the therapy of choice (class I indication) in symptomatic patients with HFrEF and a broad QRS complex with a left bundle branch block (LBBB) morphology. However, the vast majority of heart failure patients show a narrow QRS complex or a non-LBBB morphology. These patients are not candidates for CRT and alternative electrical therapies such as baroreflex activation therapy (BAT) and cardiac contractility modulation (CCM) may be considered. BAT modulates vegetative dysregulation in heart failure. CCM improves contractility, functional capacity, and symptoms. Although a broad data set is available for BAT and CCM, mortality data are still lacking for both methods. This article provides an overview of the device-based therapeutic options for patients with HFrEF.

  12. Estimating right ventricular stroke work and the pulsatile work fraction in pulmonary hypertension.

    Science.gov (United States)

    Chemla, Denis; Castelain, Vincent; Zhu, Kaixian; Papelier, Yves; Creuzé, Nicolas; Hoette, Susana; Parent, Florence; Simonneau, Gérald; Humbert, Marc; Herve, Philippe

    2013-05-01

    The mean pulmonary artery pressure (mPAP) replaces mean systolic ejection pressure (msePAP) in the classic formula of right ventricular stroke work (RVSW) = (mPAP - RAP) × stroke volume, where RAP is mean right atrial pressure. Only the steady work is thus taken into account, not the pulsatile work, whereas pulmonary circulation is highly pulsatile. Our retrospective, high-fidelity pressure study tested the hypothesis that msePAP was proportional to mPAP, and looked at the implications for RVSW. Eleven patients with severe, precapillary pulmonary hypertension (PH) (six patients with idiopathic pulmonary arterial hypertension and five with chronic thromboembolic PH; mPAP = 57 ± 10 mm Hg) were studied at rest and during mild to moderate exercise. Eight non-PH control subjects were also studied at rest (mPAP = 16 ± 2 mm Hg). The msePAP was averaged from end diastole to dicrotic notch. In the full data set (53 pressure-flow points), mPAP ranged from 14 to 99.5 mm Hg, cardiac output from 2.38 to 11.1 L/min, and heart rate from 53 to 163 beats/min. There was a linear relationship between msePAP and mPAP (r² = 0.99). The msePAP matched 1.25 mPAP (bias, -0.5 ± 2.6 mm Hg). Results were similar in the resting non-PH group and in resting and the exercising PH group. This implies that the classic formula markedly underestimates RVSW and that the pulsatile work may be a variable 20% to 55% fraction of RVSW, depending on RAP and mPAP. At rest, RVSW in patients with PH was twice as high as that of the non-PH group (P work fraction was similar between the two groups (26 ± 4% vs 24 ± 1%) because of the counterbalancing effects of high RAP (11 ± 5 mm Hg vs 4 ± 2 mm Hg), which increases the fraction, and high mPAP, which decreases the fraction. Our study favored the use of an improved formula that takes into account the variable pulsatile work fraction: RVSW = (1.25 mPAP - RAP) × stroke volume. Increased RAP and increased mPAP have opposite effects on the pulsatile work

  13. Tensor Factorization for Precision Medicine in Heart Failure with Preserved Ejection Fraction.

    Science.gov (United States)

    Luo, Yuan; Ahmad, Faraz S; Shah, Sanjiv J

    2017-06-01

    Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous clinical syndrome that may benefit from improved subtyping in order to better characterize its pathophysiology and to develop novel targeted therapies. The United States Precision Medicine Initiative comes amid the rapid growth in quantity and modality of clinical data for HFpEF patients ranging from deep phenotypic to trans-omic data. Tensor factorization, a form of machine learning, allows for the integration of multiple data modalities to derive clinically relevant HFpEF subtypes that may have significant differences in underlying pathophysiology and differential response to therapies. Tensor factorization also allows for better interpretability by supporting dimensionality reduction and identifying latent groups of data for meaningful summarization of both features and disease outcomes. In this narrative review, we analyze the modest literature on the application of tensor factorization to related biomedical fields including genotyping and phenotyping. Based on the cited work including work of our own, we suggest multiple tensor factorization formulations capable of integrating the deep phenotypic and trans-omic modalities of data for HFpEF, or accounting for interactions between genetic variants at different omic hierarchies. We encourage extensive experimental studies to tackle challenges in applying tensor factorization for precision medicine in HFpEF, including effectively incorporating existing medical knowledge, properly accounting for uncertainty, and efficiently enforcing sparsity for better interpretability.

  14. Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography - Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease

    International Nuclear Information System (INIS)

    Sohn, In; Shin, Sung Hae; Chung, June Key; Lee, Myung Chul; Cho, Bo Youn; Lee, Young Woo; Han, Yong Cheol; Koh, Chang Soon

    1982-01-01

    To evaluate the usefulness of radionuclide cardiac angiography in the assessment of the right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged 52.7±5.9% (mean±S.D.). In 25 patients with chronic obstructive lung disease, RVEF was 37.2±10.6% and significantly lower than that of normal person (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 persons without right ventricular failure (27.6±5.7%, 43.9±8.5%, respectively, p<0.01). It concluded that RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  15. Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve.

    Science.gov (United States)

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K

    2018-03-01

    Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (pvirtual resting Pd/Pa and FFR (r=0.69, pVirtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  16. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass

    Science.gov (United States)

    Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillon, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-01-01

    Importance Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, Setting, and Participants Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main Outcomes and Measures Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, −7% [95% CI, −17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse

  17. Reduced systolic performance by tissue Doppler in patients with preserved and abnormal ejection fraction: new insights in chronic heart failure.

    Science.gov (United States)

    García, Edgar H; Perna, Eduardo R; Farías, Eduardo F; Obregón, Ricardo O; Macin, Stella M; Parras, Jorge I; Agüero, Marcelo A; Moratorio, Diego A; Pitzus, Ariel E; Tassano, Eduardo A; Rodriguez, Leonardo

    2006-04-04

    Tissue Doppler imaging (TDI) is useful in the evaluation of systolic and diastolic function. It allows assessment of ventricular dynamics in its longitudinal axis. We sought to investigate the difference in systolic and diastolic longitudinal function in patients with chronic heart failure (CHF) with normal and reduced ejection fraction. One hundred ten outpatients with CHF and 68 controls were included. Ejection fraction (EF) was obtained and longitudinal systolic (S) and diastolic (E' and A') wall velocities were recorded from basal septum. Group A (controls) were normal and CHF patients were classified by EF in Group B1: > 45% and B2: < or = 45%. In A, B1 and B2 the mean S peak was 7.74; 5.45 and 4.89 cm/s (p<0.001); the mean E' peak was 8.56; 5.72 and 6.1 cm/s (p<0.001); and the mean A' peak was 10.2; 7.3 and 5.3 cm/s (p<0.001). Also, isovolumic contraction and relaxation time were different among control and CHF groups, (both p<0.001). The most useful parameters for identifying diastolic CHF were IVRT and S peak, with area under ROC curves of 0.93 and 0.89. The cut-off of 115 ms for IVRT and 5.8 cm/s for S peak showed a sensitivity of 94 and 97%, with a specificity of 82 and 73%, respectively. These findings suggest that impairment of left ventricular systolic function is present even in those with diastolic heart failure, and that abnormalities may have an important role to identifying the condition.

  18. Measurement of the ejection fraction of the left ventricle with the isotope stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Marving, J.; Hoeilund-Carlsen, P.F.; Jensen, G. (Koebenhavns Amts Sygehus, Glostrup (Denmark))

    1982-01-01

    Non-invasive measurements of left ventricular ejection fraction was performed in 21 patients by two observers with the Nuclear Stethoscope, a new, mobile, non-imaging single probe equipment. sup 99mTc was used for erythrocyte-labelling. Measurements were carried out in two different ways: beat-to-beat mode (i.e. for individual beats or a few beats at a time) and by ventricular function mode (i.e. for a composite beat, registered over a preselected period of time). There was good correlation between the two Nuclear Stethoscope modes (r=0.97) and between these and a simultaneous measurement made by gammacamera (r=0.90 and r=0.88). Despite uncertainties in the determination of correct background-level and centering over the left ventricle, there was no difference between the accuracy of the results of the two observers, compared with gammacamera measurements. The Nuclear Stethoscope is considerably cheaper than a gammacamera with computer-system, it is simple to operate, and can easily be used at the bedside, even in severely ill patients. A special feature is its capability of measuring sudden alterations in heart contractility on a beat-to-beat basis. Clinically it can be employed for both diagnostic purposes and for the monitoring of spontaneous courses and the effect of therapeutic interventions.

  19. Measurement of the ejection fraction of the left ventricle with the isotope stethoscope

    International Nuclear Information System (INIS)

    Marving, J.; Hoeilund-Carlsen, P.F.; Jensen, G.

    1982-01-01

    Non-invasive measurements of left ventricular ejection fraction was performed in 21 patients by two observers with the Nuclear Stethoscope, a new, mobile, non-imaging single probe equipment. sup 99mTc was used for erythrocyte-labelling. Measurements were carried out in two different ways: beat-to-beat mode (i.e. for individual beats or a few beats at a time) and by ventricular function mode (i.e. for a composite beat, registered over a preselected period of time). There was good correlation between the two Nuclear Stethoscope modes (r=0.97) and between these and a simultaneous measurement made by gammacamera (r=0.90 and r=0.88). Despite uncertainties in the determination of correct background-level and centering over the left ventricle, there was no difference between the accuracy of the results of the two observers, compared with gammacamera measurements. The Nuclear Stethoscope is considerably cheaper than a gammacamera with computer-system, it is simple to operate, and can easily be used at the bedside, even in severely ill patients. A special feature is its capability of measuring sudden alterations in heart contractility on a beat-to-beat basis. Clinically it can be employed for both diagnostic purposes and for the monitoring of spontaneous courses and the effect of therapeutic interventions. (authors)

  20. Changes in left ventricular systolic function in patients with chronic heart failure with preserved ejection fraction and cardiorenal anemic syndrome

    Directory of Open Access Journals (Sweden)

    Vasylenko V.A.

    2015-09-01

    Full Text Available The feature of chronic heart failure (CHF in elderly people is increasing incidence of heart failure with preserved left ventricular ejection fraction (LVEF which is associated with age. Such patients account for almost half of the total number of patients with heart failure. Cardiorenal syndrome (CRS is associated with an increased risk of mortality in patients with CHF. The impact of CRS on the structural and functional condition of the heart in these patients is studied insufficiently. The study involved 103 patients with CHF II-IV NYHA with preserved LVEF (>45% and CRS (hemoglobin <120 g/l and fractional shortening size.

  1. New echocardiographic predictors of clinical outcome in patients presenting with heart failure and a preserved left ventricular ejection fraction: a subanalysis of the Ka (Karolinska) Ren (Rennes) Study.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Persson, Hans; Reynaud, Amélie; Ennezat, Pierre-Vladimir; Bauer, Fabrice; Drouet, Elodie; Linde, Cecilia; Daubert, Claude

    2015-07-01

    To identify electrocardiographic and echocardiographic predictors of mortality and hospitalizations for heart failure (HF) in the KaRen study. KaRen is a prospective, observational study of the long-term outcomes of patients presenting with heart failure and a preserved ejection fraction (HFpEF). We identified 538 patients who presented with acute cardiac decompensation, a >100 pg/mL serum b-type natriuretic peptide (BNP) or >300 pg/mL N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration and a left ventricular ejection fraction (LVEF) >45%. After 4-8 weeks of standard treatment, 413 patients (mean age = 76 ± 9 years, 55.9% women) returned for analyses of their clinical status, laboratory screen, and detailed electrocardiographic and Doppler echocardiographic recordings. They were followed for a mean of 28 months thereafter. The primary study endpoint was time to death from all causes or first hospitalization for heart failure. Mean LVEF was 62.4 ± 6.9% and median NT-proBNP 1410 pmol/L. PR interval >200 ms was present in 11.2% of patients and 14.9% had a >120 ms QRS duration, with left bundle branch block in only 6.3%. Over a mean follow-up of 28 months, 177 patients (42.9%) reached a primary study endpoint, including 61 deaths and 116 hospitalizations for heart failure. After adjustment for age, gender, New York Heart Association class, atrial fibrillation history, creatinine, sodium, BNP, ejection fraction, and right ventricular fractional shortening, only E/e' remained as a predictor, with a hazard ratio = 1.49 and P = 0.0012. The incidence of hospitalizations for HF and deaths in KaRen was high and E/e' predicted adverse clinical outcomes. These observations should help in the risk stratification and therapy of HFpEF. © 2015 The Authors. European Journal of Heart Failure © 2015 European Society of Cardiology.

  2. Dementia-related adverse events in PARADIGM-HF and other trials in heart failure with reduced ejection fraction

    DEFF Research Database (Denmark)

    Cannon, Jane A.; Shen, Li; Jhund, Pardeep S.

    2017-01-01

    Aims: Inhibition of neprilysin, an enzyme degrading natriuretic and other vasoactive peptides, is beneficial in heart failure with reduced ejection fraction (HFrEF), as shown in PARADIGM-HF which compared the angiotensin receptor–neprilysin inhibitor (ARNI) sacubitril/valsartan with enalapril....... As neprilysin is also one of many enzymes clearing amyloid-β peptides from the brain, there is a theoretical concern about the long-term effects of sacubitril/valsartan on cognition. Therefore, we have examined dementia-related adverse effects (AEs) in PARADIGM-HF and placed these findings in the context...... of other recently conducted HFrEF trials. Methods and results: In PARADIGM-HF, patients with symptomatic HFrEF were randomized to sacubitril/valsartan 97/103 mg b.i.d. or enalapril 10 mg b.i.d. in a 1:1 ratio. We systematically searched AE reports, coded using the Medical Dictionary for Regulatory...

  3. Supernova mass ejection and core hydrodynamics

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1978-01-01

    Simplifications that have emerged in the descriptions of stellar unstable collapse to a neutron star are discussed. The neutral current weak interaction leads to almost complete neutrino trapping in the collapse and to an electron fraction Y/sub e/ congruent to 0.35 in equilibrium with trapped electron neutrinos and ''iron'' nuclei. A soft equation of state (γ congruent to 1.30) leads to collapse, and bounce occurs on a hard core, γ = 2.5, at nuclear densities. Neutrino emission is predicted from a photosphere at r congruent to 2 x 10 7 cm and E/sub ν/ congruent to 10 MeV. The ejection of matter by an elastic core bounce and a subsequent escaping shock is marginal and may not be predicted for accurate values of the equation of state. A new concept of Rayleigh-Taylor driven core instabilities is invoked to predict an increased mass ejection either due to an increased flux and energy of neutrinos at second bounce time and, or, the rapid 0.1 to 0.4 second formation of a more energetically bound neutron star. The instability is caused by highly neutronized external matter from which neutrinos have escaped being supported by lighter matter of the lepton trapped core. An initial anisotropy of 10 -2 to 10 -3 should lead to adequately rapid (several milliseconds) overturn following several (2 to 4) bounces. Subsequent to the overturnwith or without a strong ejection shock, a weak ejection shock will allow an accretion shock to form on the ''cold'' neutron star core due to the reimplosion or rarefaction wave in the weakly ejected matter. The accretion shock forms at low enough mass accumulation rate, 1 / 2 M/sub solar/ sec -1 , such that a black body neutrino flux can escape from the shock front (kT congruent to 10 MeV, [E/sub ν/] congruent to 30 MeV). This strongly augments the weaker bounce ejection shock by heating the external matter in the mantle by electron neutrino scattering (congruent to 10 52 ergs) causing adequate mass ejection

  4. Prognostic value and limitations of exercise radionuclide angiography in medically treated coronary artery disease

    International Nuclear Information System (INIS)

    Taliercio, C.P.; Clements, I.P.; Zinsmeister, A.R.; Gibbons, R.J.

    1988-01-01

    We investigated whether exercise radionuclide angiography provides prognostic information in addition to that identified by resting left ventricular function and coronary anatomy in patients with medically treated coronary artery disease. Clinical follow-up (median, 21.7 months) was obtained in 424 medically treated patients who underwent exercise radionuclide angiography and coronary angiography. The mean age of the study population was 58 years, and 67% were men. Cardiac death occurred in 16 patients, nonfatal myocardial infarction in 16, and nonfatal out-of-hospital cardiac arrest in 1. Univariate analysis showed that multiple variables were associated with future cardiac events, including number of diseased vessels, exercise and rest radionuclide ejection fraction, history of myocardial infarction, exercise and rest left ventricular end-systolic and end-diastolic volume indices, peak exercise workload, age, abnormal resting electrocardiogram, and peak exercise ST-segment depression. Only three variables were independently associated with cardiac events on follow-up: number of diseased vessels, radionuclide ejection fraction at rest, and age. In patients with three-vessel disease and a resting radionuclide ejection fraction of more than 40%, a subgroup with higher risk could not be identified on the basis of exercise radionuclide response

  5. Impact of early, late, and no ST-segment resolution measured by continuous ST Holter monitoring on left ventricular ejection fraction and infarct size as determined by cardiovascular magnetic resonance imaging

    NARCIS (Netherlands)

    Haeck, Joost D. E.; Verouden, Niels J. W.; Kuijt, Wichert J.; Koch, Karel T.; Majidi, Mohamed; Hirsch, Alexander; Tijssen, Jan G. P.; Krucoff, Mitchell W.; de Winter, Robbert J.

    2011-01-01

    Background: The goal of this study is to determine the predictive value of ST-segment resolution (STR) early after percutaneous coronary intervention (PCI), late STR, and no STR for left ventricular ejection fraction (LVEF) and infarct size (IS) by cardiovascular magnetic resonance (CMR) at

  6. [Sacubitril/valsartan, a new and effective treatment for heart failure with reduced ejection fraction].

    Science.gov (United States)

    Senni, Michele; Trimarco, Bruno; Emdin, Michele; De Biase, Luciano

    2017-01-01

    Despite significant therapeutic advances, patients with chronic heart failure and reduced ejection fraction (HFrEF) remain at high risk for heart failure progression and death. The PARADIGM-HF study, the largest outcome trial in HFrEF, has shown improved cardiovascular outcomes with sacubitril/valsartan (Entresto®, Novartis), previously known as LCZ696, compared with angiotensin-converting enzyme (ACE) inhibitor therapy, possibly leading us to a new era for heart failure treatment. Sacubitril/valsartan represents a first-in-class drug acting through inhibition of angiotensin receptor and neprilysin, thus modulating the renin-angiotensin-aldosterone system and vasoactive substances such as natriuretic peptides. This approach can be considered a "paradigm shift" from neurohumoral inhibition to neurohumoral modulation. Based on the PARADIGM-HF results, the European Society of Cardiology and the American Heart Association/American College of Cardiology guidelines proposed a substitution of ACE-inhibitor/angiotensin receptor blocker therapy rather than an "add-on" strategy in HFrEF. Sacubitril/valsartan can be considered a milestone in cardiovascular therapy, like aspirin, statins, beta-blockers. Of course there are many questions that arise spontaneously from this trial, three recognized experts can help us to answer them.

  7. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  8. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    International Nuclear Information System (INIS)

    Benjelloun, H.; Brochier, M.; Itti, R.; Philippe, L.; Lorgeron, J.M.

    1983-01-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition. (orig.)

  9. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Benjelloun, H; Brochier, M; Itti, R; Philippe, L; Lorgeron, J M

    1983-05-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition.

  10. Evaluation of left cardiac function by exercise in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Horayama, Norihisa; Hamada, Masayuki; Nakano, Takeshi; Takezawa, Hideo

    1981-01-01

    Left ventricular systolic and diastolic features at rest and exercise in hypertrophic cardiomyopathy were evaluated by Fourier analysis of blood pool scintigraphy (intracorporeal labelling with sup(99m)Tc-RBC). In the normal group (17 subjects), the left ventricular ejection fraction showed a linear increase, but no abnormality of regional ventricular wall motion, by multistage exercises. The hypertrophic cardiomyopathy group showed higher left ventricular ejection fractions at rest than those of the normal group, and in the HCM group (non-obstructive, from morphological features; 7 cases) the left ventricular ejection fraction did not increase any more when it reached a certain plateau in accordance with increased stress. In the HOCM (obstructive; 5 cases), the left ventricular ejection fraction showed a decreasing tendency as the stress was increased and also showed contractile abnormalities from the left ventricular center to the apex. Fourier analysis was effective for the evaluation of these changes. (Chiba, N.)

  11. High Right Ventricular Stroke Work Index Is Associated with Worse Kidney Function in Patients with Heart Failure with Preserved Ejection Fraction.

    Science.gov (United States)

    Kanjanahattakij, Napatt; Sirinvaravong, Natee; Aguilar, Francisco; Agrawal, Akanksha; Krishnamoorthy, Parasuram; Gupta, Shuchita

    2018-01-01

    In patients with heart failure with preserved ejection fraction (HFpEF), worse kidney function is associated with worse overall cardiac mechanics. Right ventricular stroke work index (RVSWI) is a parameter of right ventricular function. The aim of our study was to determine the relationship between RVSWI and glomerular filtration rate (GFR) in patients with HFpEF. This was a single-center cross-sectional study. HFpEF is defined as patients with documented heart failure with ejection fraction > 50% and pulmonary wedge pressure > 15 mm Hg from right heart catheterization. RVSWI (normal value 8-12 g/m/beat/m2) was calculated using the formula: RVSWI = 0.0136 × stroke volume index × (mean pulmonary artery pressure - mean right atrial pressure). Univariate and multivariate linear regression analysis was performed to study the correlation between RVSWI and GFR. Ninety-one patients were included in the study. The patients were predominantly female (n = 64, 70%) and African American (n = 61, 67%). Mean age was 66 ± 12 years. Mean GFR was 59 ± 35 mL/min/1.73 m2. Mean RVSWI was 11 ± 6 g/m/beat/m2. Linear regression analysis showed that there was a significant independent inverse relationship between RVSWI and GFR (unstandardized coefficient = -1.3, p = 0.029). In the subgroup with combined post and precapillary pulmonary hypertension (Cpc-PH) the association remained significant (unstandardized coefficient = -1.74, 95% CI -3.37 to -0.11, p = 0.04). High right ventricular workload indicated by high RVSWI is associated with worse renal function in patients with Cpc-PH. Further prospective studies are needed to better understand this association. © 2018 S. Karger AG, Basel.

  12. Adaptive servo-ventilation to treat central sleep apnea in heart failure with reduced ejection fraction: the Bad Oeynhausen prospective ASV registry.

    Science.gov (United States)

    Oldenburg, Olaf; Wellmann, Birgit; Bitter, Thomas; Fox, Henrik; Buchholz, Anika; Freiwald, Eric; Horstkotte, Dieter; Wegscheider, Karl

    2018-04-13

    Central sleep apnea (CSA) is highly prevalent in heart failure patients with reduced left ventricular ejection fraction (HF-REF). The Bad Oeynhausen Adaptive Servo-ventilation (ASV) registry (NCT01657188) was designed to investigate whether treatment of CSA with ASV improved survival in HF-REF patients; the effects of ASV on symptoms and cardiopulmonary performance were also investigated. From January 2004 to October 2013, the registry prospectively enrolled HF-REF patients [NYHA class ≥ II, left ventricular ejection fraction (LVEF) ≤ 45%] with moderate to severe predominant CSA [apnea-hypopnea index (AHI) ≥ 15/h]. ASV-treated patients were followed up at 3, 6, 12 and 24 months, including natriuretic peptide concentrations, blood gas analyses, echocardiography, 6-min walk distance (6MWD), and cardiopulmonary exercise (CPX) testing. 550 patients were included [age 67.7 ± 10 years, 90% male, 52% in NYHA class ≥ III, LVEF 29.9 ± 8%, AHI 35.4 ± 13.6/h, and time with nocturnal oxygen saturation concentration, and nocturnal hypoxemia were significant predictors of mortality. Patient reported NYHA functional class improved in the ASV group, but LVEF, CPX, 6MWD, natriuretic peptides and blood gases remained unchanged. Long-term ASV treatment of predominant CSA in HF-REF patients included in our registry had no statistically significant effect on survival. ASV improved HF symptoms, but had no significant effects on exercise capacity, LVEF, natriuretic peptide concentrations or blood gases during follow-up as compared to control patients.

  13. The impact of coronary artery disease and left ventricular ejection fraction on the prognosis of patients with peripheral artery disease.

    Science.gov (United States)

    Tsujimura, Takuya; Iida, Osamu; Ishihara, Takayuki; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Takahara, Mitsuyoshi; Uematsu, Masaaki

    2017-11-01

    The impact of the severity of coronary artery disease (CAD) and left ventricular ejection fraction (LVEF) on the prognosis of patients with peripheral artery disease (PAD) has not been systematically studied. We retrospectively analysed 622 patients with PAD (intermittent claudication (IC): n = 446; critical limb ischaemia (CLI): n = 176). The association of SYNTAX score and LVEF with mortality was analysed using the Cox proportional hazard model. In patients with IC, a high SYNTAX score was significantly associated with mortality, whereas reduced LVEF was significantly associated with mortality in patients with CLI. The prognostic impact of CAD and LVEF appears different between patients with IC and CLI. © 2017 Royal Australasian College of Physicians.

  14. Assessment of various systolic phase indexes for the detection of coronary artery disease by multi-gated blood pool imaging at rest

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke

    1982-01-01

    After Tc-99m was labeled with red blood cells in vivo, multi-gated blood pool imaging (MGBPI) was obtained at anterior and 40-degree left anterior oblique (LAO) position at rest. In addition to left ventricular (LV) ejection fraction (EF) and wall motion (WM) abnormality, first-third EF, mean normalized systolic ejection rate, SdV/dt/EDV (LV peak ejection rate normalized by end-diastolic volume) and SdV/dt/V (peak ejection rate normalized by LV volume at the peak ejection) were calculated. Patients were divided into 3 groups; Normal (n = 14), coronary artery disease (CAD) with normal EF (> = 55%) and normal WM (Group I, n = 16), and CAD with abnormal EF and/or WM abnormality (Group II, n = 31). In all subjects of Normal and 13 patients of Group I, graded supine exercise stress MGBPI was performed at LAO position by using bicycle ergometer. All systolic phase indexes were correlated well with EF (r > = 0.77, p - 1 , p - 1 as a criteria of CAD, sensitivity of this index was 91% (100% in Group II and 75% in Group I). This sensitivity in Group I was identical with that of exercise stress MGBPI. Specificity of SdV/dt/V (86%) was a little inferior to that of exercise stress MGBPI (93%), but it was not statistically significant. In conclusion, SdV/dt/V is a useful systolic phase index to detect CAD. (J.P.N.)

  15. Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.

    Science.gov (United States)

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2018-02-01

    Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF. We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAV max ) - Minimum LA volume (LAV min ), LA emptying fraction = [(LAV max - LAV min )/LAV max ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A 2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004). Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF. © 2017 Wiley Periodicals, Inc.

  16. Computer-assisted determination of left ventricular endocardial borders reduces variability in the echocardiographic assessment of ejection fraction

    Directory of Open Access Journals (Sweden)

    Lindstrom Lena

    2008-11-01

    Full Text Available Abstract Background Left ventricular size and function are important prognostic factors in heart disease. Their measurement is the most frequent reason for sending patients to the echo lab. These measurements have important implications for therapy but are sensitive to the skill of the operator. Earlier automated echo-based methods have not become widely used. The aim of our study was to evaluate an automatic echocardiographic method (with manual correction if needed for determining left ventricular ejection fraction (LVEF based on an active appearance model of the left ventricle (syngo®AutoEF, Siemens Medical Solutions. Comparisons were made with manual planimetry (manual Simpson, visual assessment and automatically determined LVEF from quantitative myocardial gated single photon emission computed tomography (SPECT. Methods 60 consecutive patients referred for myocardial perfusion imaging (MPI were included in the study. Two-dimensional echocardiography was performed within one hour of MPI at rest. Image quality did not constitute an exclusion criterion. Analysis was performed by five experienced observers and by two novices. Results LVEF (%, end-diastolic and end-systolic volume/BSA (ml/m2 were for uncorrected AutoEF 54 ± 10, 51 ± 16, 24 ± 13, for corrected AutoEF 53 ± 10, 53 ± 18, 26 ± 14, for manual Simpson 51 ± 11, 56 ± 20, 28 ± 15, and for MPI 52 ± 12, 67 ± 26, 35 ± 23. The required time for analysis was significantly different for all four echocardiographic methods and was for uncorrected AutoEF 79 ± 5 s, for corrected AutoEF 159 ± 46 s, for manual Simpson 177 ± 66 s, and for visual assessment 33 ± 14 s. Compared with the expert manual Simpson, limits of agreement for novice corrected AutoEF was lower than for novice manual Simpson (0.8 ± 10.5 vs. -3.2 ± 11.4 LVEF percentage points. Calculated for experts and with LVEF (% categorized into Conclusion Corrected AutoEF reduces the variation in measurements compared with

  17. Physiological dead space and arterial carbon dioxide contributions to exercise ventilatory inefficiency in patients with reduced or preserved ejection fraction heart failure.

    Science.gov (United States)

    Van Iterson, Erik H; Johnson, Bruce D; Borlaug, Barry A; Olson, Thomas P

    2017-12-01

    Patients with heart failure (HF) with reduced (HFrEF) or preserved (HFpEF) ejection fraction demonstrate an increased ventilatory equivalent for carbon dioxide (V̇ E /V̇CO 2 ) slope. The physiological correlates of the V̇ E /V̇CO 2 slope remain unclear in the two HF phenotypes. We hypothesized that changes in the physiological dead space to tidal volume ratio (V D /V T ) and arterial CO 2 tension (PaCO 2 ) differentially contribute to the V̇ E /V̇CO 2 slope in HFrEF vs. HFpEF. Adults with HFrEF (n = 32) and HFpEF (n = 27) [mean ± standard deviation (SD) left ventricular ejection fraction: 22 ± 7% and 61 ± 9%, respectively; mean ± SD body mass index: 28 ± 4 kg/m 2 and 33 ± 6 kg/m 2 , respectively; P breath-by-breath ventilation and gas exchange measurements. PaCO 2 was measured via radial arterial catheterization. We calculated the V̇ E /V̇CO 2 slope via linear regression, and V D /V T  = 1 - [(863 × V̇CO 2 )/(V̇ E  × PaCO 2 )]. Resting V D /V T (0.48 ± 0.08 vs. 0.41 ± 0.11; P = 0.04), but not PaCO 2 (38 ± 5 mmHg vs. 40 ± 3 mmHg; P = 0.21) differed between HFrEF and HFpEF. Peak exercise V D /V T (0.39 ± 0.08 vs. 0.32 ± 0.12; P = 0.02) and PaCO 2 (33 ± 6 mmHg vs. 38 ± 4 mmHg; P < 0.01) differed between HFrEF and HFpEF. The V̇ E /V̇CO 2 slope was higher in HFrEF compared with HFpEF (44 ± 11 vs. 35 ± 8; P < 0.01). Variance associated with the V̇ E /V̇CO 2 slope in HFrEF and HFpEF was explained by peak exercise V D /V T (R 2  = 0.30 and R 2  = 0.50, respectively) and PaCO 2 (R 2  = 0.64 and R 2  = 0.28, respectively), but the relative contributions of each differed (all P < 0.01). Relationships between the V̇ E /V̇CO 2 slope and both V D /V T and PaCO 2 are robust, but differ between HFpEF and HFrEF. Increasing V̇ E /V̇CO 2 slope appears to be strongly explained by mechanisms influential in

  18. COMPOSITION OF CORONAL MASS EJECTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zurbuchen, T. H.; Weberg, M.; Lepri, S. T. [Department of Climate and Space Sciences and Engineering, University of Michigan, Ann Arbor, MI (United States); Von Steiger, R. [International Space Science Institute, Bern (Switzerland); Mewaldt, R. A. [California Institute of Technology, Pasadena, CA (United States); Antiochos, S. K. [Heliophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD (United States)

    2016-07-20

    We analyze the physical origin of plasmas that are ejected from the solar corona. To address this issue, we perform a comprehensive analysis of the elemental composition of interplanetary coronal mass ejections (ICMEs) using recently released elemental composition data for Fe, Mg, Si, S, C, N, Ne, and He as compared to O and H. We find that ICMEs exhibit a systematic abundance increase of elements with first ionization potential (FIP) < 10 eV, as well as a significant increase of Ne as compared to quasi-stationary solar wind. ICME plasmas have a stronger FIP effect than slow wind, which indicates either that an FIP process is active during the ICME ejection or that a different type of solar plasma is injected into ICMEs. The observed FIP fractionation is largest during times when the Fe ionic charge states are elevated above Q {sub Fe} > 12.0. For ICMEs with elevated charge states, the FIP effect is enhanced by 70% over that of the slow wind. We argue that the compositionally hot parts of ICMEs are active region loops that do not normally have access to the heliosphere through the processes that give rise to solar wind. We also discuss the implications of this result for solar energetic particles accelerated during solar eruptions and for the origin of the slow wind itself.

  19. Baseline characteristics of patients with heart failure and preserved ejection fraction included in the Karolinska Rennes (KaRen) study.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Persson, Hans; Reynaud, Amélie; Ennezat, Pierre-Vladimir; Bauer, Fabrice; Sportouch-Dukhan, Catherine; Drouet, Elodie; Daubert, Jean-Claude; Linde, Cecilia

    2014-02-01

    Karolinska Rennes (KaRen) is a prospective observational study to characterize heart failure patients with preserved ejection fraction (HFpEF) and to identify prognostic factors for long-term mortality and morbidity. To report characteristics and echocardiography at entry and after 4-8 weeks of follow-up. Patients were included following an acute heart failure presentation with B-type natriuretic peptide (BNP)>100 ng/L or N-terminal pro-BNP (NT-proBNP)>300 ng/L and left ventricular ejection fraction (LVEF)>45%. The mean ± SD age of 539 included patients was 77 ± 9 years and 56% were women. Patient history included hypertension (78%), atrial tachyarrhythmia (44%), prior heart failure (40%) and anemia (37%), but left bundle branch block was rare (3.8%). Median NT-proBNP was 2448 ng/L (n=438), and median BNP 429 ng/L (n=101). Overall, 101 patients did not return for the follow-up visit, including 13 patients who died (2.4%). Apart from older age (80 ± 9 vs. 76 ± 9 years; P=0.006), there were no significant differences in baseline characteristics between patients who did and did not return for follow-up. Mean LVEF was lower at entry than follow-up (56% vs. 62%; P<0.001). At follow-up, mean E/e' was 12.9 ± 6.1, left atrial volume index 49.4±17.8mL/m(2). Mean global left ventricular longitudinal strain was -14.6 ± 3.9%; LV mass index was 126.6 ± 36.2g/m(2). Patients in KaRen were old with slight female dominance and hypertension as the most prevalent etiological factor. LVEF was preserved, but with increased LV mass and depressed LV diastolic and longitudinal systolic functions. Few patients had signs of electrical dyssynchrony (ClinicalTrials.gov.- NCT00774709). Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. Correlation between sleep apnea syndrome and heart failure depending on ejection fraction

    Directory of Open Access Journals (Sweden)

    Carmen Loredana Ardelean

    2016-12-01

    Full Text Available OBJECTIVES The aim of this study was to analyze the correlations between sleep apnea syndrome(SAS and heart failure(HF in patients with preserved or reduced ejection fraction(EF. MATERIALS AND METHODS We evaluated 51 patients with suspected SAS and HF in sleep lab in Timișoara. General data was collected using sleep questionnaires, anthropometric measurements, somnography for apnea-hypopnea index, oxygen desaturation index, echocardiographic data, comorbidities and lab tests. RESULTS Creatinine -1.1±0.2 vs 1.4±0.7, p=0.05; stroke-23% vs 4%, p=0.04; aortic insufficiency-11.5% vs 36%, p=0.04; tricuspid insufficiency-46.1% vs 80%, p=0.01. Differences between groups regarding anthropometric measurements, somnographic index, lipidic profile were not statistically significant.. CONCLUSIONS Patients with SAS-IC with preserved EF have a higher risk of stroke events. Patients with IC with EF<50% had a significantly increased risk of developing a life-long chronic kidney disease. The SAS-IC population with low EF is at a higher risk of developing aortic and tricuspid insufficiency. REFERENCES 1. Douglas T. Sleep Apnea and Heart Failure. Part1: Obstructive Sleep Apnea. Circulation.2003.107:1671-1678. 2. Takatoshi K, Douglas TB. Obstructive Sleep Apnea and Heart Failure-Pathophysiologic and Therapeutic Implication. Journal of the American College of Cardiology. 2011; 57:doi: 10.1016/j.jacc.2010.08.627 3. Ferrier K, Campbell A, Yee B et al. Sleepdisordered breathing occurs frequently in stable outpatients with congestive heart failure. Chest. 2005;128:2116–2122.

  1. Increased left ventricular ejection fraction after a meal: potential source of error in performance of radionuclide angiography

    International Nuclear Information System (INIS)

    Brown, J.M.; White, C.J.; Sobol, S.M.; Lull, R.J.

    1983-01-01

    The effect of a standardized meal on left ventricular (LV) ejection fraction (EF) was determined by equilibrium radionuclide angiography in 16 patients with stable congestive heart failure but without pulmonary or valvular heart disease. LVEF was determined in the fasting state and 15, 30, and 45 minutes after a meal. Patients with moderately depressed fasting LVEF (30 to 50%), Group I, had a mean increase of 6.9 +/- 2.9% (p less than 0.005) in the LVEF at 45 minutes after the meal. Patients with severely depressed fasting LVEF (less than 30%), Group II, had no change after the meal. It is concluded that significant increases in LVEF may occur after meals in patients with moderate but not severe left ventricular dysfunction. Equilibrium radionuclide angiography studies that are not standardized for patients' mealtimes may introduce an important unmeasured variable that will affect the validity of data in serial studies of left ventricular function

  2. Increased left ventricular ejection fraction after a meal: potential source of error in performance of radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J.M.; White, C.J.; Sobol, S.M.; Lull, R.J.

    1983-06-01

    The effect of a standardized meal on left ventricular (LV) ejection fraction (EF) was determined by equilibrium radionuclide angiography in 16 patients with stable congestive heart failure but without pulmonary or valvular heart disease. LVEF was determined in the fasting state and 15, 30, and 45 minutes after a meal. Patients with moderately depressed fasting LVEF (30 to 50%), Group I, had a mean increase of 6.9 +/- 2.9% (p less than 0.005) in the LVEF at 45 minutes after the meal. Patients with severely depressed fasting LVEF (less than 30%), Group II, had no change after the meal. It is concluded that significant increases in LVEF may occur after meals in patients with moderate but not severe left ventricular dysfunction. Equilibrium radionuclide angiography studies that are not standardized for patients' mealtimes may introduce an important unmeasured variable that will affect the validity of data in serial studies of left ventricular function.

  3. Influence of magnification on the calculated value of left ventricular ejection fraction and volumes using quantitative gated perfusion SPECT

    International Nuclear Information System (INIS)

    Nunez, M.; Beretta, M.; Alonso, O.; Alvarez, B.; Canepa, J.; Mut, F.

    2002-01-01

    Aim: To compare left ventricular ejection fraction (LVEF), end-diastolic volumes (EDV) and end-systolic volumes (ESV) measured by quantitative gated SPECT (QGSPECT) in studies acquired with and without magnification factor (zoom). Material and Methods: We studied 30 consecutive patients (17 men, ages 61±14 years) referred for myocardial perfusion evaluation with a 2-day protocol. Studies were performed after injection of 925 MBq (25 mCi) of 99mTc-MIBI in the resting state. Gated SPECT was first acquired using a x2 zoom factor and immediately repeated with x1 zoom (no magnification), using a 64x64 matrix and 8 frames/cardiac cycle. Patients with arrhythmia were not included in the investigation. According to the median EDV calculated with the x2 zoom acquisition, the population was further divided in two sub-groups regarding the size of the LV cavity. Average LVEF, EDV, ESV and difference between values (delta) were then calculated for the total population and for each sub-group (a and b). Results: For the total population, results are expressed.Pearson correlation showed r=0.954 between LVEF with and without zoom (p<0.0001), but linear regression analysis did not fit a specific model (p=0.18). Median EDV with zoom was 92.5 ml, allowing to separate 15 cases with EDV above (a) and 15 below that value (b). Results for both sub-groups are presented. Conclusion: Calculated LVEF is higher with no zoom, at the expense of decreasing both EDV and ESV. Although differences were very significant for all parameters, ESV changes were specially relevant with no zoom, particularly in patients with smaller hearts. Although good correlation was found between LVEF with and without zoom, no specific correction factor was found to convert one value into the other. Magnification factor should be kept constant in gated SPECT if calculated LVEF values QGSPECT are expected to be reliable, and validation of the method using different zoom factors should be considered

  4. Heart Failure With Preserved Ejection Fraction in Diabetes: Mechanisms and Management.

    Science.gov (United States)

    Meagher, Patrick; Adam, Mohamed; Civitarese, Robert; Bugyei-Twum, Antoinette; Connelly, Kim A

    2018-05-01

    Diabetes mellitus (DM) is a major cause of heart failure in the Western world, either secondary to coronary artery disease or from a distinct entity known as "diabetic cardiomyopathy." Furthermore, heart failure with preserved ejection fraction (HFpEF) is emerging as a significant clinical problem for patients with DM. Current clinical data suggest that between 30% and 40% of patients with HFpEF suffer from DM. The typical structural phenotype of the HFpEF heart consists of endothelial dysfunction, increased interstitial and perivascular fibrosis, cardiomyocyte stiffness, and hypertrophy along with advanced glycation end products deposition. There is a myriad of mechanisms that result in the phenotypical HFpEF heart including impaired cardiac metabolism and substrate utilization, altered insulin signalling leading to protein kinase C activation, advanced glycated end products deposition, prosclerotic cytokine activation (eg, transforming growth factor-β activation), along with impaired nitric oxide production from the endothelium. Moreover, recent investigations have focused on the role of endothelial-myocyte interactions. Despite intense research, current therapeutic strategies have had little effect on improving morbidity and mortality in patients with DM and HFpEF. Possible explanations for this include a limited understanding of the role that direct cell-cell communication or indirect cell-cell paracrine signalling plays in the pathogenesis of DM and HFpEF. Additionally, integrins remain another important mediator of signals from the extracellular matrix to cells within the failing heart and might play a significant role in cell-cell cross-talk. In this review we discuss the characteristics and mechanisms of DM and HFpEF to stimulate potential future research for patients with this common, and morbid condition. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. The Nitrate-nitrite-NO pathway and its implications for Heart Failure and Preserved Ejection Fraction

    Science.gov (United States)

    Chirinos, Julio A.; Zamani, Payman

    2016-01-01

    The pathogenesis of exercise intolerance in patients with heart failure and preserved ejection fraction (HFpEF) is likely multifactorial. In addition to cardiac abnormalities (diastolic dysfunction, abnormal contractile reserve, chronotropic incompetence), several peripheral abnormalities are likely to be involved. These include abnormal pulsatile hemodynamics, abnormal arterial vasodilatory responses to exercise, and abnormal peripheral O2 delivery, extraction and utilization. The nitrate-nitrite-NO pathway is emerging as a potential target to modify key physiologic abnormalities, including late systolic LV load from arterial wave reflections (which has deleterious short- and long-term consequences for the LV), arterial vasodilatory reserve, muscle O2 delivery, and skeletal muscle mitochondrial function. In a recently completed randomized trial, the administration of a single dose of exogenous inorganic nitrate has been shown exert various salutary arterial hemodynamic effects, ultimately leading to enhanced aerobic capacity in patients with HFpEF. These effects have the potential for both immediate improvements in exercise tolerance and for long-term “disease-modifying” effects. In this review, we provide an overview of key mechanistic contributors to exercise intolerance in HFpEF, and of the potential therapeutic role of drugs that target the nitrate-nitrite-NO pathway. PMID:26792295

  6. Pulmonary thallium uptake: Correlation with systolic and diastolic left ventricular function at rest and during exercise

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary 201-thallium uptake, assessed as pulmonary/myocardial ratios (PM) and body surface area-corrected absolute pulmonary uptake (Pc), was determined from single photon emission computed tomography studies in 22 normal subjects and 46 consecutive patients with coronary artery disease (CAD). By means of equilibrium radionuclide angiography (ERNA), ejection fraction (EF), peak ejection rate (PER) in end-diastolic volume (EDV/sec) and peak filling rate (PFR) in EDV/sec and stroke volume (SV/sec) units, PFR/PER ratio, and time to peak filling rate (TPFR) in milliseconds were computed at rest and during exercise (n = 35). Left ventricular response to exercise was assessed as delta EF, relative delta EF, delta EDV, and delta ESV. In normal subjects the PM ratios showed significant inverse correlation with PER at rest and with EF, PER, and PFRedv during exercise. For the left ventricular response to exercise, delta ESV showed significant correlation with the PM ratios. The body surface area-corrected pulmonary uptake values showed no correlation with any of the variables. In patients with CAD the PM ratios and Pc uptake showed significant inverse correlation with EF, PER, PFRedv and to exercise EF, exercise PER, and exercise PFRedv. For the left ventricular response to exercise, delta EF showed significant inverse correlation with the PM ratios but not with the Pc uptake. Neither in normal subjects nor in patients with CAD did any of the independent diastolic variables show significant correlation with the PM ratios or Pc values. Thus pulmonary thallium uptake is correlated with systolic left ventricular function at rest and during exercise in normal subjects and in patients with CAD but not with diastolic function. In normal subjects delta ESV and in patients with CAD, delta EF showed correlation with pulmonary thallium uptake

  7. Left ventricle ejection fraction obtained by radioisotopic angiocardiography. Correlation between the values of the conventional ventriclegraphy

    International Nuclear Information System (INIS)

    Ascer, E.; Pimentel Filho, W.A.; Martins, L.R.F.; Marioni Filho, H.; Queiroga Filho, A.F.; Alonso, G.; Germek, O.A.; Thom, A.F.; Souza, J.E.M.R.

    1983-01-01

    Forty-two patients with clinical signs of coronary insuficiency underwent cineangiographic and radioisotopic examinations with the purpose of analysing the correlation between the values of left ventricle ejection fraction (LVEF) obtained by both methods. The values of EF obtained by the hemodynamic method (HEMO) ranged from 0.14 to 0.85 (x-bar = 0.566) and by radioisotopic method (RM) from 0.22 to 0.89 (x-bar = 0.573). The Student T test did not demonstrate statistically significant differences between the two methods (mean of differences = 0.007; t = 0.38 and p ≥ 0.353). A regression equation was obtained in order to estimate the EF by HEMO deriving from results obtained by RM (y = 0.11 + 0.80x) and to estimate the EF through RN from the results obtained by HEMO (x = 0.08 + 0.86y), where y = hemodynamic method and x = radioisotopic method. The authors conclude that the calculation of the EF by the methods used showed a good correlation and that this fact is evidenced by the elevated Pearson's correlation coefficient (r = 0.833). (author) [pt

  8. Causes and Temporal Patterns of 30-Day Readmission Among Older Adults Hospitalized With Heart Failure With Preserved or Reduced Ejection Fraction.

    Science.gov (United States)

    Goyal, Parag; Loop, Matthew; Chen, Ligong; Brown, Todd M; Durant, Raegan W; Safford, Monika M; Levitan, Emily B

    2018-04-23

    It is unknown whether causes and temporal patterns of 30-day readmission vary between heart failure (HF) with preserved ejection fraction (HFpEF) and HF with reduced ejection fraction (HFrEF). We sought to address this question by examining a 5% national sample of Medicare beneficiaries. We included individuals who experienced a hospitalization for HFpEF or HFrEF between 2007 and 2013. We identified causes of 30-day readmission based on primary discharge diagnosis and further classified causes of readmission as HF-related, non-HF cardiovascular-related, and non-cardiovascular-related. We calculated the cumulative incidence of these classifications for HFpEF and HFrEF in a competing risks model and calculated subdistribution hazard ratios of these classifications by comparing those with HFpEF and those with HFrEF. Among 60 640 Medicare beneficiaries, we identified 13 785 unique older adults hospitalized with HFpEF and 15 205 who were hospitalized with HFrEF. Noncardiovascular diagnoses represented the most common causes of 30-day readmission (HFpEF: 59%; HFrEF: 47%), a pattern that was observed for each week of the 30-day study period for both HFpEF and HFrEF participants. In comparing readmission diagnoses in an adjusted model, non-cardiovascular-related diagnoses were more common and HF-related diagnoses were less common in HFpEF participants. Non-cardiovascular-related diagnoses represented the most common causes of 30-day readmission following HF hospitalization for each week of the 30-day postdischarge period. HF diagnoses were less common among those with HFpEF compared with HFrEF. Future interventions aimed at reducing 30-day readmissions following an HF hospitalization would benefit from an increased focus on noncardiovascular comorbidity and interventions that target HFpEF and HFrEF separately. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  9. Right heart dysfunction and failure in heart failure with preserved ejection fraction: mechanisms and management. Position statement on behalf of the Heart Failure Association of the European Society of Cardiology.

    Science.gov (United States)

    Gorter, Thomas M; van Veldhuisen, Dirk J; Bauersachs, Johann; Borlaug, Barry A; Celutkiene, Jelena; Coats, Andrew J S; Crespo-Leiro, Marisa G; Guazzi, Marco; Harjola, Veli-Pekka; Heymans, Stephane; Hill, Loreena; Lainscak, Mitja; Lam, Carolyn S P; Lund, Lars H; Lyon, Alexander R; Mebazaa, Alexandre; Mueller, Christian; Paulus, Walter J; Pieske, Burkert; Piepoli, Massimo F; Ruschitzka, Frank; Rutten, Frans H; Seferovic, Petar M; Solomon, Scott D; Shah, Sanjiv J; Triposkiadis, Filippos; Wachter, Rolf; Tschöpe, Carsten; de Boer, Rudolf A

    2018-01-01

    There is an unmet need for effective treatment strategies to reduce morbidity and mortality in patients with heart failure with preserved ejection fraction (HFpEF). Until recently, attention in patients with HFpEF was almost exclusively focused on the left side. However, it is now increasingly recognized that right heart dysfunction is common and contributes importantly to poor prognosis in HFpEF. More insights into the development of right heart dysfunction in HFpEF may aid to our knowledge about this complex disease and may eventually lead to better treatments to improve outcomes in these patients. In this position paper from the Heart Failure Association of the European Society of Cardiology, the Committee on Heart Failure with Preserved Ejection Fraction reviews the prevalence, diagnosis, and pathophysiology of right heart dysfunction and failure in patients with HFpEF. Finally, potential treatment strategies, important knowledge gaps and future directions regarding the right side in HFpEF are discussed. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.

  10. Peak oxygen uptake and left ventricular ejection fraction, but not depressive symptoms, are associated with cognitive impairment in patients with chronic heart failure.

    Science.gov (United States)

    Steinberg, Gerrit; Lossnitzer, Nicole; Schellberg, Dieter; Mueller-Tasch, Thomas; Krueger, Carsten; Haass, Markus; Ladwig, Karl Heinz; Herzog, Wolfgang; Juenger, Jana

    2011-01-01

    The aim of the present study was to assess cognitive impairment in patients with chronic heart failure (CHF) and its associations with depressive symptoms and somatic indicators of illness severity, which is a matter of controversy. Fifty-five patients with CHF (mean age 55.3 ± 7.8 years; 80% male; New York Heart Association functional class I-III) underwent assessment with an expanded neuropsychological test battery (eg, memory, complex attention, mental flexibility, psychomotor speed) to evaluate objective and subjective cognitive impairment. Depressive symptoms were assessed using the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (SCID) and a self-report inventory (Hospital Anxiety and Depression Scale [HADS]). A comprehensive clinical dataset, including left ventricular ejection fraction, peak oxygen uptake, and a 6-minute walk test, was obtained for all patients. Neuropsychological functioning revealed impairment in 56% of patients in at least one measure of our neuropsychological test battery. However, the Mini Mental State Examination (MMSE) could only detect cognitive impairment in 1.8% of all patients, 24% had HADS scores indicating depressive symptoms, and 11.1% met SCID criteria for a depressive disorder. No significant association was found between depressive symptoms and cognitive impairment. Left ventricular ejection fraction was related to subjective cognitive impairment, and peak oxygen uptake was related to objective cognitive impairment. Cognitive functioning was substantially reduced in patients with CHF and should therefore be diagnosed and treated in routine clinical practice. Caution is advised when the MMSE is used to identify cognitive impairment in patients with CHF.

  11. Influence of ST-segment recovery on infarct size and ejection fraction in patients with ST-segment elevation myocardial infarction receiving primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Hallén, Jonas; Ripa, Maria Sejersten; Johanson, Per

    2010-01-01

    percutaneous coronary intervention. Three methods for calculating and categorizing ST-segment recovery were used: (1) summed ST-segment deviation (STD) resolution analyzed in 3 categories (> or = 70%, > or = 30% to or = 2 mm). Infarct size and ejection fraction were assessed at 4 months by cardiac magnetic...... resonance imaging. All 3 ST-segment recovery algorithms predicted the final infarct size and cardiac function. Worst-lead residual STD performed the same as, or better than, the more complex methods and identified large subgroups at either end of the risk spectrum (median infarct size from the lowest...

  12. Multicenter core laboratory comparison of the instantaneous wave-free ratio and resting Pd/Pa with fractional flow reserve: The RESOLVE study

    NARCIS (Netherlands)

    Jeremias, Allen; Maehara, Akiko; Généreux, Philippe; Asrress, Kaleab N.; Berry, Colin; Bruyne, de B. (Bernard); Davies, Justin E.; Escaned, Javier; Fearon, W.F. (William); Gould, K. Lance; Johnson, Nils P.; Kirtane, Ajay J.; Koo, Bon Kwon; Marques, Koen M.; Nijjer, Sukhjinder; Oldroyd, K.G. (Keith); Petraco, Ricardo; Piek, Jan J.; Pijls, Nico H.; Redwood, Simon; Siebes, M.; Spaan, J.A.E.; van 't Veer, Marcel; Mintz, Gary S.; Stone, Gregg W.

    2014-01-01

    Objectives This study sought to examine the diagnostic accuracy of the instantaneous wave-free ratio (iFR) and resting distal coronary artery pressure/aortic pressure (Pd/Pa) with respect to hyperemic fractional flow reserve (FFR) in a core laboratory-based multicenter collaborative study.

  13. Prediction of improvement of myocardial wall motion after coronary artery bypass surgery using rest Tl-201/dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Lee, Won Woo; Yeo, Jeong Yeo; Kim, Seok Ki; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul

    1998-01-01

    Using rest Tl-201/ dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), Tl-201 rest perfusion (Rest), Tl-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. In 39 patients (M:F=34:5, age 58±8), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. After bypass surgery, ejection fraction increased from 37.8±9.0% to 45.5±12.3% in 22 patients who had decreased ejectin fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Through univariate logistic regression analysis revealed Rev( p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Among independent predictors obtained by rest Tl-201/stress gated Tc-99m-MIBI/delayed Tl-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor

  14. Preoperative left ventricular ejection fraction and left atrium reverse remodeling after mitral regurgitation surgery.

    Science.gov (United States)

    Machado, Lucia R; Meneghelo, Zilda M; Le Bihan, David C S; Barretto, Rodrigo B M; Carvalho, Antonio C; Moises, Valdir A

    2014-11-06

    Left atrium enlargement has been associated with cardiac events in patients with mitral regurgitation (MR). Left atrium reverse remodeling (LARR) occur after surgical correction of MR, but the preoperative predictors of this phenomenon are not well known. It is therefore important to identify preoperative predictors for postoperative LARR. We enrolled 62 patients with chronic severe MR (prolapse or flail leaflet) who underwent successful mitral valve surgery (repair or replacement); all with pre- and postoperative echocardiography. LARR was defined as a reduction in left atrium volume index (LAVI) of ≥ 25%. Stepwise multiple regression analysis was used to identify independent predictors of LARR. LARR occurred in 46 patients (74.2%), with the mean LAVI decreasing from 85.5 mL/m2 to 49.7 mL/m2 (p <0.001). These patients had a smaller preoperative left ventricular systolic volume (p =0.022) and a higher left ventricular ejection fraction (LVEF) (p =0.034). LVEF was identified as the only preoperative variable significantly associated with LARR (odds ratio, 1.086; 95% confidence interval, 1.002-1.178). A LVEF cutoff value of 63.5% identified patients with LARR of ≥ 25% with a sensitivity of 71.7% and a specificity of 56.3%. LARR occurs frequently after mitral valve surgery and is associated with preoperative LVEF higher than 63.5%.

  15. Worsening Renal Function during Management for Chronic Heart Failure with Reduced Ejection Fraction: Results From the Pro-BNP Outpatient Tailored Chronic Heart Failure Therapy (PROTECT) Study.

    Science.gov (United States)

    Ibrahim, Nasrien E; Gaggin, Hanna K; Rabideau, Dustin J; Gandhi, Parul U; Mallick, Aditi; Januzzi, James L

    2017-02-01

    To assess prognostic meaning of worsening renal failure (WRF) occurring during management of chronic heart failure (HF) with reduced ejection fraction. When WRF develops during titration of HF medical therapy, it commonly leads to less aggressive care. A total of 151 patients enrolled in a prospective, randomized study of standard of care (SOC) HF therapy versus SOC plus a goal N-terminal pro-B type natriuretic peptide (NT-proBNP) renal function. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. REST: a toolkit for resting-state functional magnetic resonance imaging data processing.

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Song

    Full Text Available Resting-state fMRI (RS-fMRI has been drawing more and more attention in recent years. However, a publicly available, systematically integrated and easy-to-use tool for RS-fMRI data processing is still lacking. We developed a toolkit for the analysis of RS-fMRI data, namely the RESting-state fMRI data analysis Toolkit (REST. REST was developed in MATLAB with graphical user interface (GUI. After data preprocessing with SPM or AFNI, a few analytic methods can be performed in REST, including functional connectivity analysis based on linear correlation, regional homogeneity, amplitude of low frequency fluctuation (ALFF, and fractional ALFF. A few additional functions were implemented in REST, including a DICOM sorter, linear trend removal, bandpass filtering, time course extraction, regression of covariates, image calculator, statistical analysis, and slice viewer (for result visualization, multiple comparison correction, etc.. REST is an open-source package and is freely available at http://www.restfmri.net.

  17. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass: The LICORN Randomized Clinical Trial.

    Science.gov (United States)

    Cholley, Bernard; Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillion, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-08-08

    Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, -7% [95% CI, -17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Among patients with low ejection fraction

  18. Multicenter core laboratory comparison of the instantaneous wave-free ratio and resting Pd/Pa with fractional flow reserve: the RESOLVE study

    NARCIS (Netherlands)

    Jeremias, Allen; Maehara, Akiko; Généreux, Philippe; Asrress, Kaleab N.; Berry, Colin; de Bruyne, Bernard; Davies, Justin E.; Escaned, Javier; Fearon, William F.; Gould, K. Lance; Johnson, Nils P.; Kirtane, Ajay J.; Koo, Bon-Kwon; Marques, Koen M.; Nijjer, Sukhjinder; Oldroyd, Keith G.; Petraco, Ricardo; Piek, Jan J.; Pijls, Nico H.; Redwood, Simon; Siebes, Maria; Spaan, Jos A. E.; van 't Veer, Marcel; Mintz, Gary S.; Stone, Gregg W.

    2014-01-01

    This study sought to examine the diagnostic accuracy of the instantaneous wave-free ratio (iFR) and resting distal coronary artery pressure/aortic pressure (Pd/Pa) with respect to hyperemic fractional flow reserve (FFR) in a core laboratory-based multicenter collaborative study. FFR is an index of

  19. Resting Pd/Pa and haemodynamic relevance of coronary stenosis as evaluated by fractional flow reserve.

    Science.gov (United States)

    De Luca, Giuseppe; Verdoia, Monica; Barbieri, Lucia; Marino, Paolo; Suryapranata, Harry

    2018-03-01

    Fractional flow reserve (FFR) currently represents the gold standard in the evaluation of the haemodynamic relevance of coronary stenoses. However, both intracoronary and intravenous adenosine may be tolerated poorly by some patients. Therefore, considerable interest had been focused in the last few years on new adenosine-free indexes to define the haemodynamic relevance of coronary stenoses. So far, few data have been reported on resting Pd/Pa and its correlation with FFR as evaluated with high-dose intracoronary adenosine administration, which is the aim of the current study. FFR was assessed in 120 patients with 137 intermediate lesions during cardiac catheterization by a pressure-recording guidewire (PrimeWire). FFR was calculated as the ratio of the distal coronary pressure to the aortic pressure at hyperaemia. Intracoronary doses of adenosine were administered up to 720 μg as intracoronary boli. Exclusion criteria were as follows: (a) allergy to adenosine; (b) baseline bradycardia (heart rate values and increased the percentage of patients showing an FFR less than 0.80. Resting Pd/Pa showed good accuracy in the identification of patients with significant FFR values (value in the prediction of a positive FFR value. A value up to 0.88 was associated with a 100% positive predictive value, whereas a value of at least 0.95 was associated with a 95% negative predictive value. This study showed that in intermediate lesions, resting Pd/Pa was related linearly to FFR. We identified 0.93 as the best cut-off value in the prediction of haemodynamically significant coronary stenosis as evaluated by FFR. However, cut-off values of 0.88 and 0.95 could provide the maximal predictive positive and negative values, suggesting the additional use of FFR only in patients with resting values within this range.

  20. Analysis of a control rod ejection transient in a mox-fuelled PWR

    International Nuclear Information System (INIS)

    Lenain, R.; Mathonniere, G.; Perrutel, J.P.; Schaeffer, H.; Stelletta, S.; Lam Hime, M.

    1988-09-01

    The decision to use mixed-oxide (MOX) fuel in PWR's involved re-investigation of a certain number of accidents and notably control rod ejection transients. It has thus been shown that this accident would be no more severe than in the case of all-uranium cores, since the positive effects on the ejected rod worth would counterbalance the negative effects on the delayed neutron fraction. A new approach to the kinetics aspect of the calculation method for this accident is also presented, involving a 3-D kinetic calculation with only a few axial meshes

  1. Proton ejection project for Saturne; Projet d'ejection des protons de saturne

    Energy Technology Data Exchange (ETDEWEB)

    Bronca, G; Gendreau, G

    1959-07-01

    The reasons for choosing the ejection system are given. The characteristics required for the ejected beam are followed by a description of the ejection process, in chronological order from the viewpoint of the protons: movement of the particles, taking into account the various elements which make up the system (internal magnet, external magnet, quadrupoles, ejection correction coils, thin and thick cables,...) and specification of these elements. Then follows an estimation of the delay in manufacture and the cost of the project. Finally, the characteristics of the magnets and quadrupoles are listed in an appendix. (author) [French] On donne d'abord les raisons du choix du systeme d'ejection, puis le principe. Apres les caracteristiques requises pour le faisceau ejecte, on decrit le processus d'ejection selon l'ordre chronologique vu par les protons: mouvement des particules compte tenu des divers elements composant le systeme (aimant interne, aimant externe, quadrupoles, enroulements correcteurs ejection, cibles mince et epaisse,. ..) et cahier de charge de ces elements. On estime, ensuite les delais de realisation et le cout du projet. Enfin, un resume des caracteristiques des aimants et quadrupoles est donne en appendice. (auteur)

  2. Reproducibility in the analysis of multigated radionuclide studies of left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Gjorup, T.; Kelbaek, H.; Vestergaard, B.; Fogh, J.; Munck, O.; Jensen, A.M.

    1989-01-01

    The authors determined the reproducibility (the standard deviation [SD]) in the analysis of multigated radionuclide studies of left ventricular ejection fraction (LVEF). Radionuclide studies from a consecutive series of 38 patients suspected of ischemic heart disease were analyzed independently by four nuclear medicine physiologists and four laboratory technicians. Each study was analyzed three times by each of the observers. Based on the analyses of the eight observers, the SD could be estimated by the use of a variance component model for LVEF determinations calculated as the average of the analyses of an arbitrary number of observers making an arbitrary number of analyses. This study presents the SDs for LVEF determinations based on the analyses of one to five observers making one to five analyses each. The SD of a LVEF determination decreased from 3.96% to 2.98% when an observer increased his number of analyses from one to five. A more pronounced decrease in the SD from 3.96% to 1.77% was obtained when the LVEF determinations were based on the average of a single analysis made by one to five observers. However, when dealing with the difference between LVEF determinations from two studies, the highest reproducibility was obtained if the LVEF determinations at both studies were based on the analyses made by the same observer. No significant difference was found in the reproducibility of analyses made by nuclear medicine physicians and laboratory technicians. Our study revealed that to increase the reproducibility of LVEF determinations, special efforts should be made to standardize the outlining of the end-systolic region interest

  3. Relation of Renal Function with Left Ventricular Systolic Function and NT-proBNP Level and Its Prognostic Implication in Heart Failure with Preserved versus Reduced Ejection Fraction: an analysis from the Korean Heart Failure (KorHF) Registry.

    Science.gov (United States)

    Park, Chan Soon; Park, Jin Joo; Oh, Il-Young; Yoon, Chang-Hwan; Choi, Dong-Ju; Park, Hyun-Ah; Kang, Seok-Min; Yoo, Byung-Su; Jeon, Eun-Seok; Kim, Jae-Joong; Cho, Myeong-Chan; Chae, Shung Chull; Ryu, Kyu-Hyung; Oh, Byung-Hee

    2017-09-01

    The relationship between ejection fraction (EF), N-terminal pro-brain natriuretic peptide (NT-proBNP) levels and renal function is unknown as stratified by heart failure (HF) type. We investigated their relation and the prognostic value of renal function in heart failure with preserved ejection fraction (HFpEF) vs. reduced ejection fraction (HFrEF). NT-proBNP, glomerular filtration rate (GFR), and EF were obtained in 1,932 acute heart failure (AHF) patients. HFrEF was defined as EFrenal dysfunction as GFRrenal dysfunction: 30≤GFRrenal dysfunction: GFRrenal dysfunction did not differ between HFpEF and HFrEF (49% vs. 52%, p=0.210). Patients with renal dysfunction had higher 12-month mortality in both HFpEF (7.9% vs. 15.2%, log-rank p=0.008) and HFrEF (8.6% vs. 16.8%, log-rank prenal dysfunction was an independent predictor of 12-month mortality (hazard ratio [HR], 2.08; 95% confidence interval [CI], 1.40-3.11). When stratified according to EF: the prognostic value of severe renal dysfunction was attenuated in HFpEF patients (HR, 1.46; 95% CI, 0.66-3.21) contrary to HFrEF patients (HR, 2.43; 95% CI, 1.52-3.89). In AHF patients, the prevalence of renal dysfunction did not differ between HFpEF and HFrEF patients. However, the prognostic value of renal dysfunction was attenuated in HFpEF patients.

  4. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease

    International Nuclear Information System (INIS)

    Gibbons, R.J.

    1991-01-01

    Rest and exercise radionuclide angiography is frequently employed for the diagnosis of chest pain syndromes. Its value and limitations in this regard have been well studied, but proper utilization of the technique requires an understanding of five critical concepts: (1) Radionuclide angiography is superior to treadmill exercise testing and probably equivalent to thallium scintigraphy, although the published series did not use current methods. (2) The true specificity of radionuclide angiography is about 80%, intermediate between the early optimistic estimates and the later pessimistic ones. (3) The peak exercise ejection fraction is the preferred test parameter for diagnosis, although exercise hemodynamics, symptoms, and electrocardiographic changes should also be considered. (4) Although radionuclide angiography is clearly helpful for noninvasive diagnosis, significant numbers of patients will continue to fall in an uncertain category. (5) The proper application of the technique requires recognition of its limitations and careful attention to technical details. When properly applied, this modality can make an important contribution to clinical decision making. 58 references

  5. Clinical events in coronary heart disease patients with an ejection fraction of 40% or less: 3-year follow-up results.

    Science.gov (United States)

    Pischke, Claudia R; Elliott-Eller, Melanie; Li, Minmin; Mendell, Nancy; Ornish, Dean; Weidner, Gerdi

    2010-01-01

    It is unclear whether lifestyle changes can delay the need for surgical procedures in coronary heart disease (CHD) patients with asymptomatic reduced left ventricular ejection fraction (LVEF). The aim of this pilot study was to examine whether lifestyle changes can delay the need for surgical procedures in this population. We compared 3-year clinical events in 27 CHD patients eligible to receive revascularization (by insurance standards), but underwent lifestyle changes (low-fat diet, exercise, stress management) instead (intervention group [IG], LVEF Lifestyle Demonstration Project, an insurance-sponsored, community-based, secondary prevention study implemented at 8 hospital sites in the United States. At 3 months, there were more cardiac events in the UCG (6 events) than in the IG (1 event; P changes in lifestyle with no increased risk for cardiac events or overt heart failure over 3 years.

  6. Cardiac Involvement in Myotonic Dystrophy Type 2 Patients With Preserved Ejection Fraction: Detection by Cardiovascular Magnetic Resonance.

    Science.gov (United States)

    Schmacht, Luisa; Traber, Julius; Grieben, Ulrike; Utz, Wolfgang; Dieringer, Matthias A; Kellman, Peter; Blaszczyk, Edyta; von Knobelsdorff-Brenkenhoff, Florian; Spuler, Simone; Schulz-Menger, Jeanette

    2016-07-01

    Myotonic dystrophy type 2 (DM2) is a genetic disorder characterized by skeletal muscle symptoms, metabolic changes, and cardiac involvement. Histopathologic alterations of the skeletal muscle include fibrosis and fatty infiltration. The aim of this study was to investigate whether subclinical cardiac involvement in DM2 is already detectable in preserved left ventricular function by cardiovascular magnetic resonance. Twenty-seven patients (mean age, 54±10 years; 20 females) with a genetically confirmed diagnosis of DM2 were compared with 17 healthy age- and sex-matched controls using a 1.5 T magnetic resonance imaging. For myocardial tissue differentiation, T1 and T2 mapping, fat/water-separated imaging, focal fibrosis imaging (late gadolinium enhancement [LGE]), and (1)H magnetic resonance spectroscopy were performed. Extracellular volume fraction was calculated. Conduction abnormalities were diagnosed based on Groh criteria. LGE located subepicardial basal inferolateral was detectable in 22% of the patients. Extracellular volume was increased in this region and in the adjacent medial inferolateral segment (P=0.03 compared with healthy controls). In 21% of patients with DM2, fat deposits were detectable (all women). The control group showed no abnormalities. Myocardial triglycerides were not different in LGE-positive and LGE-negative subjects (P=0.47). Six patients had indicators for conduction disease (60% of LGE-positive patients and 12.5% of LGE-negative patients). In DM2, subclinical myocardial injury was already detectable in preserved left ventricular ejection fraction. Extracellular volume was also increased in regions with no focal fibrosis. Myocardial fibrosis was related to conduction abnormalities. © 2016 American Heart Association, Inc.

  7. Gated blood pool scintigraphy in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Breuel, H.P.; Heusinger, J.H.; Hanisch, K.

    1984-10-01

    In 58 patients suffering from either stenosis or insufficiency of a single heart valve, gated blood pool scintigraphy was performed to determine the ejection fraction as well as the peak filling and peak ejection rates. It could be demonstrated that in patients with valvular disorders the ejection fraction was only moderately decreased, generally remaining in the lower reference range. The peak filling and ejection rates showed no pathologic changes with the exception of patients with aortic regurgitation where these rates were significantly decreased. Thus, the estimation of left ventricular peak filling and ejection rates may permit diagnosis of myocardial impairment in patients with valvular disease even under resting conditions.

  8. Effects of beta-blockers on heart failure with preserved ejection fraction: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Feng Liu

    Full Text Available BACKGROUND: Effects of beta-blockers on the prognosis of the heart failure patients with preserved ejection fraction (HFpEF remain controversial. The aim of this meta-analysis was to determine the impact of beta-blockers on mortality and hospitalization in the patients with HFpEF. METHODS: A search of MEDLINE, EMBASE, and the Cochrane Library databases from 2005 to June 2013 was conducted. Clinical studies reporting outcomes of mortality and/or hospitalization for patients with HFpEF (EF ≥ 40%, being assigned to beta-blockers treatment and non-beta-blockers control group were included. RESULTS: A total of 12 clinical studies (2 randomized controlled trials and 10 observational studies involving 21,206 HFpEF patients were included for this meta-analysis. The pooled analysis demonstrated that beta-blocker exposure was associated with a 9% reduction in relative risk for all-cause mortality in patients with HFpEF (95% CI: 0.87 - 0.95; P < 0.001. Whereas, the all-cause hospitalization, HF hospitalization and composite outcomes (mortality and hospitalization were not affected by this treatment (P=0.26, P=0.97, and P=0.88 respectively. CONCLUSIONS: The beta-blockers treatment for the patients with HFpEF was associated with a lower risk of all-cause mortality, but not with a lower risk of hospitalization. These finding were mainly obtained from observational studies, and further investigations are needed to make an assertion.

  9. Renin-Angiotensin Activation and Oxidative Stress in Early Heart Failure with Preserved Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Smita I. Negi

    2015-01-01

    Full Text Available Animal models have suggested a role of renin-angiotensin system (RAS activation and subsequent cardiac oxidation in heart failure with preserved ejection fraction (HFpEF. Nevertheless, RAS blockade has failed to show efficacy in treatment of HFpEF. We evaluated the role of RAS activation and subsequent systemic oxidation in HFpEF. Oxidative stress markers were compared in 50 subjects with and without early HFpEF. Derivatives of reactive oxidative metabolites (DROMs, F2-isoprostanes (IsoPs, and ratios of oxidized to reduced glutathione (Eh GSH and cysteine (Eh CyS were measured. Angiotensin converting enzyme (ACE levels and activity were measured. On univariate analysis, HFpEF was associated with male sex (p=0.04, higher body mass index (BMI (p=0.003, less oxidized Eh CyS (p=0.001, lower DROMs (p=0.02, and lower IsoP (p=0.03. Higher BMI (OR: 1.3; 95% CI: 1.1–1.6 and less oxidized Eh CyS (OR: 1.2; 95% CI: 1.1–1.4 maintained associations with HFpEF on multivariate analysis. Though ACE levels were higher in early HFpEF (OR: 1.09; 95% CI: 1.01–1.05, ACE activity was similar to that in controls. HFpEF is not associated with significant systemic RAS activation or oxidative stress. This may explain the failure of RAS inhibitors to alter outcomes in HFpEF.

  10. An Early View of Real-World Patient Response to Sacubitril/Valsartan: A Retrospective Study of Patients with Heart Failure with Reduced Ejection Fraction.

    Science.gov (United States)

    Antol, Dana Drzayich; Casebeer, Adrianne Waldman; DeClue, Richard W; Stemkowski, Stephen; Russo, Patricia A

    2018-06-01

    Sacubitril/valsartan has been established as an effective treatment for heart failure (HF) with reduced ejection fraction based on clinical trial data; however, little is known about its use or impact in real-world practice. This study included data from medical and pharmacy claims and medical records review for patients (n = 200) who initiated sacubitril/valsartan between August 2015 and March 2016 preceding issuance of American College of Cardiology (ACC)/American Heart Association (AHA)/Heart Failure Society of America (HFSA) focused update on new pharmacological therapy for HF (May 2016), which included recommendations for sacubitril/valsartan. A within-subject analysis compared symptoms and healthcare resource utilization before and after treatment initiation. Patients treated with sacubitril/valsartan had multiple comorbidities, and nearly all had previous treatment for HF. Most patients initiated sacubitril/valsartan at the lowest dose of 24/26 mg twice a day (BID), which remained unchanged during the observation period for half of the patients. During the first 6 weeks of treatment, few patients discontinued sacubitril/valsartan treatment (5.5%), and only 17% achieved the target dose of 97/103 mg BID after 4 months of treatment. The proportion of patients with ≥ 1 all-cause inpatient stay decreased significantly between the pre-initiation period (27.5%) and the post-initiation period (17.0%), P = 0.009. Fatigue was noted in 51.8% of patients pre-initiation and 39.5% post-initiation, P = 0.027. Shortness of breath was documented for 66.7% of patients pre-initiation and 51.8% post-initiation, P = 0.008. The findings of this real-world investigation suggest sacubitril/valsartan is associated with symptom improvements and a reduction in hospitalizations within 4 months of treatment for patients with HF and reduced ejection fraction. Novartis Pharmaceuticals Corporation.

  11. Regional interaction between myocardial sympathetic denervation, contractile dysfunction, and fibrosis in heart failure with preserved ejection fraction: {sup 11}C-hydroxyephedrine PET study

    Energy Technology Data Exchange (ETDEWEB)

    Aikawa, Tadao; Naya, Masanao; Obara, Masahiko [Hokkaido University, Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Sapporo (Japan); Oyama-Manabe, Noriko [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Manabe, Osamu [Hokkaido University, Department of Nuclear Medicine, Faculty of Medicine and Graduate School of Medicine, Sapporo (Japan); Magota, Keiichi [Hokkaido University Hospital, Division of Medical Imaging and Technology, Sapporo (Japan); Ito, Yoichi M. [Hokkaido University, Department of Biostatistics, Faculty of Medicine and Graduate School of Medicine, Sapporo (Japan); Katoh, Chietsugu [Hokkaido University, Department of Biomedical Science and Engineering, Faculty of Health Sciences, Sapporo (Japan); Tamaki, Nagara [Kyoto Prefectural University of Medicine, Department of Radiology, Kyoto (Japan)

    2017-10-15

    This investigation aimed to identify significant predictors of regional sympathetic denervation quantified by {sup 11}C-hydroxyephedrine (HED) positron emission tomography (PET) in patients with heart failure with preserved left ventricular ejection fraction (HFpEF). Included in the study were 34 patients (age 63 ± 15 years, 23 men) with HFpEF (left ventricular ejection fraction ≥40%) and 11 age-matched volunteers without heart failure. Cardiac magnetic resonance imaging was performed to measure left ventricular size and function, and the extent of myocardial late gadolinium enhancement (LGE). {sup 11}C-HED PET was performed to quantify myocardial sympathetic innervation that was expressed as a {sup 11}C-HED retention index (RI, %/min). To identify predictors of regional {sup 11}C-HED RI in HFpEF patients, we propose a multivariate mixed-effects model for repeated measures over segments with an unstructured covariance matrix. Global {sup 11}C-HED RI was significantly lower and more heterogeneous in HFpEF patients than in volunteers (P < 0.01 for all). Regional {sup 11}C-HED RI was correlated positively with systolic wall thickening (r = 0.42, P < 0.001) and negatively with the extent of LGE (r = -0.43, P < 0.001). Segments in HFpEF patients with a large extent of LGE had the lowest regional {sup 11}C-HED RI among all segments (P < 0.001 in post hoc tests). Multivariate analysis demonstrated that systolic wall thickening and the extent of LGE were significant predictors of regional {sup 11}C-HED RI in HFpEF patients (both P ≤ 0.001). Regional sympathetic denervation was associated with contractile dysfunction and fibrotic burden in HFpEF patients, suggesting that regional sympathetic denervation may provide an integrated measure of myocardial damage in HFpEF. (orig.)

  12. Stress hormones at rest and following exercise testing predict coronary artery disease severity and outcome.

    Science.gov (United States)

    Popovic, Dejana; Damjanovic, Svetozar; Djordjevic, Tea; Martic, Dejana; Ignjatovic, Svetlana; Milinkovic, Neda; Banovic, Marko; Lasica, Ratko; Petrovic, Milan; Guazzi, Marco; Arena, Ross

    2017-09-01

    Despite considerable knowledge regarding the importance of stress in coronary artery disease (CAD) pathogenesis, its underestimation persists in routine clinical practice, in part attributable to lack of a standardized, objective assessment. The current study examined the ability of stress hormones to predict CAD severity and prognosis at basal conditions as well as during and following an exertional stimulus. Forty Caucasian subjects with significant coronary artery lesions (≥50%) were included. Within 2 months of coronary angiography, cardiopulmonary exercise testing (CPET) on a recumbent ergometer was performed in conjunction with stress echocardiography (SE). At rest, peak and after 3 min of recovery following CPET, plasma levels of cortisol, adrenocorticotropic hormone (ACTH) and NT-pro-brain natriuretic peptide (NT-pro-BNP) were measured by immunoassay sandwich technique, radioimmunoassay, and radioimmunometric technique, respectively. Subjects were subsequently followed a mean of 32 ± 10 months. Mean ejection fraction was 56.7 ± 9.6%. Subjects with 1-2 stenotic coronary arteries (SCA) demonstrated a significantly lower plasma cortisol levels during CPET compared to those with 3-SCA (p  .05). Among CPET, SE, and hormonal parameters, cortisol at rest and during CPET recovery demonstrated the best predictive value in distinguishing between 1-, 2-, and 3-SCA [area under ROC curve 0.75 and 0.77 (SE = 0.11, 0.10; p = .043, .04) for rest and recovery, respectively]. ΔCortisol peak/rest predicted cumulative cardiac events (area under ROC curve 0.75, SE = 0.10, p = .049). Cortisol at rest and following an exercise test holds predictive value for CAD severity and prognosis, further demonstrating a link between stress and unwanted cardiac events.

  13. Fractional amplitude analysis of low frequency fluctuation in alcohol dependent individuals: a resting state functional MRI study

    International Nuclear Information System (INIS)

    Yan Dingfang; Cheng Jun; Wu Hanbin; Xu Liangzhou; Liu Jinhuan; Zhao Yilin; Lin Xue; Liu Changsheng; Qiu Li

    2012-01-01

    Objective: To explore brain activity features during the resting state in alcohol dependent individuals, and study the relationship between the brain activity features and alcohol dependent individuals' clinical symptoms. Methods: Twenty-four alcohol dependent individuals and 22 healthy control subjects, well matched in gender, age, education and handedness, were enrolled as the alcohol dependent group and control group respectively. A GE 3.0 T MR scanner was used to acquire all the subjects' resting state data. DPARSF software was used to process resting functional MRI data, and then the whole brain fractional amplitudes of low frequency fluctuation (fALFF) data were acquired. Two-sample t test statistical analysis was made to access fALFF difference between the two groups. Results: In comparison with the control group, the alcohol dependent group showed reduced fALFF in bilateral medial prefrontal gyrus, right inferior occipital gyrus, left precuneus,left inferior temporal gyrus, and left posterior lobe of cerebellum (0.64-1.69 vs. 0.87-1.78, t=-4.23- -2.79, P<0.05). fALFF was increased in the alcohol dependent group at the anterior cingulate,bilateral inferior frontal gyrus,right middle frontal gyrus,bilateral insular lobe,bilateral dorsal thalamus (0.86-1.82 vs. 0.76-1.58, t=3.56-3.96, P<0.05). Conclusion: Alcohol dependent individuals had abnormal activity at the bilateral prefrontal lobe,anterior cingulate, bilateral dorsal thalamus, bilateral insular lobe, left posterior lobe of cerebellum et al, during the resting state, and these abnormal activities might be related with clinical manifestation and pathophysiology. (authors)

  14. EJECTION AND CAPTURE DYNAMICS IN RESTRICTED THREE-BODY ENCOUNTERS

    International Nuclear Information System (INIS)

    Kobayashi, Shiho; Hainick, Yanir; Sari, Re'em; Rossi, Elena M.

    2012-01-01

    We study the tidal disruption of binaries by a massive point mass (e.g., the black hole at the Galactic center), and we discuss how the ejection and capture preference between unequal-mass binary members depends on which orbit they approach the massive object. We show that the restricted three-body approximation provides a simple and clear description of the dynamics. The orbit of a binary with mass m around a massive object M should be almost parabolic with an eccentricity of |1 – e| ∼ 1/3 1/3 times the binary rotation velocity, it would be abruptly disrupted, and the energy change at the encounter can be evaluated in a simple disruption model. We evaluate the probability distributions for the ejection and capture of circular binary members and for the final energies. In principle, for any hyperbolic (elliptic) orbit, the heavier member has more chance to be ejected (captured), because it carries a larger fraction of the orbital energy. However, if the orbital energy is close to zero, the difference between the two members becomes small, and there is practically no ejection and capture preferences. The preference becomes significant when the orbital energy is comparable to the typical energy change at the encounter. We discuss its implications to hypervelocity stars and irregular satellites around giant planets.

  15. Effects of upright and supine position on cardiac rest and exercise response in aortic regurgitation.

    Science.gov (United States)

    Shen, W F; Roubin, G S; Fletcher, P J; Choong, C Y; Hutton, B F; Harris, P J; Kelly, D T

    1985-02-01

    The effects of upright and supine position on cardiac response to exercise were assessed by radionuclide ventriculography in 15 patients with moderate to severe aortic regurgitation (AR) and in 10 control subjects. In patients with AR, heart rate was higher during upright exercise, but systolic and diastolic blood pressure and left ventricular (LV) output were similar during both forms of exercise. LV stroke volume and end-diastolic volume were not altered during supine exercise. LV end-systolic volume increased and ejection fraction decreased during supine exercise, but both were unchanged during upright exercise. Of 15 patients, 5 in the upright and 12 in the supine position had an abnormal LV ejection fraction response to exercise (p less than 0.01). Right ventricular ejection fraction increased and regurgitant index decreased with both forms of exercise and was not significantly different between the 2 positions. Thus, posture is important in determining LV response to exercise in patients with moderate to severe AR.

  16. Prognostic significance of hemoglobin level in patients with congestive heart failure and normal ejection fraction.

    Science.gov (United States)

    Varadarajan, Padmini; Gandhi, Siddharth; Sharma, Sanjay; Umakanthan, Branavan; Pai, Ramdas G

    2006-10-01

    Previous studies have shown low hemoglobin (Hb) to have an adverse effect on survival in patients with congestive heart failure (CHF) and reduced left ventricular (LV) ejection fraction (EF); but its effect on survival in patients with CHF and normal EF is not known. This study sought to determine whether low Hb has an effect on survival in patients with both CHF and normal EF. Detailed chart reviews were performed by medical residents on 2,246 patients (48% with normal EF) with a discharge diagnosis of CHF in a large tertiary care hospital from 1990 to 1999. The CHF diagnosis was validated using the Framingham criteria. Mortality data were obtained from the National Death Index. Survival analysis was performed using Kaplan-Meier and Cox regression models. By Kaplan-Meier analysis, low Hb (< 12 gm/dl) compared with normal hemoglobin was associated with a lower 5-year survival in patients with CHF and both normal (38 vs. 50%, p = 0.0008) and reduced (35 vs. 48%, p = 0.0009) EF. Using the Cox regression model, low Hb was an independent predictor of mortality after adjusting for age, gender, renal dysfunction, diabetes mellitus, hypertension, and EF in both groups of patients. Low Hb has an independent adverse effect on survival in patients with CHF and both normal and reduced EF in both groups of patients.

  17. Serial assessment of left ventricular function following coronary bypass surgery by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Sakakibara, Naoki; Iwa, Takashi; Taki, Junichi; Bunko, Hisashi

    1988-01-01

    The serial change in left ventricular function was investigated by radionuclide angiocardiography in 25 patients undergoing coronary artery bypass grafting (CABG). Multiple gated equilibrium blood pool imaging was performed at rest before, and at 1, 2 and 4 weeks after the operation and also during exercise on a supine bicycle ergometer before and 4 weeks after surgery. Global ejection fraction at rest was unchanged after CABG while peak ejection rate increased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05 respectively) after the operation. Peak filling rate at rest was generally unchanged after surgery but peak filling rate during the first third of diastole at rest decreased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05). After CABG, the increases in ejection fraction and peak ejection rate with exercise were significantly greater than those values measured before surgery. The increases, due to exercise, in peak filling rate and peak filling rate during the first third of diastole were unchanged after the operation. Radionuclide angiocardiography affords a safe, noninvasive, and highly reproducible procedure for serially assessing ventricular function in patients undergoing CABG. Our study revealed early diastolic dysfunction within 2 weeks of surgery and that CABG abolished abnormalities in left ventricular function induced by exercise. (author)

  18. Prevalence of symptomatic heart failure with reduced and with normal ejection fraction in an elderly general population-the CARLA study.

    Directory of Open Access Journals (Sweden)

    Daniel Tiller

    Full Text Available BACKGROUND/OBJECTIVES: Chronic heart failure (CHF is one of the most important public health concerns in the industrialized world having increasing incidence and prevalence. Although there are several studies describing the prevalence of heart failure with reduced ejection fraction (HFREF and heart failure with normal ejection fraction (HFNEF in selected populations, there are few data regarding the prevalence and the determinants of symptomatic heart failure in the general population. METHODS: Cross-sectional data of a population-based German sample (1,779 subjects aged 45-83 years were analyzed to determine the prevalence and determinants of chronic SHF and HFNEF defined according to the European Society of Cardiology using symptoms, echocardiography and serum NT-proBNP. Prevalence was age-standardized to the German population as of December 31st, 2005. RESULTS: The overall age-standardized prevalence of symptomatic CHF was 7.7% (95%CI 6.0-9.8 for men and 9.0% (95%CI 7.0-11.5 for women. The prevalence of CHF strongly increased with age from 3.0% among 45-54- year-old subjects to 22.0% among 75-83- year-old subjects. Symptomatic HFREF could be shown in 48% (n = 78, symptomatic HFNEF in 52% (n = 85 of subjects with CHF. The age-standardized prevalence of HFREF was 3.8 % (95%CI 2.4-5.8 for women and 4.6 % (95%CI 3.6-6.3 for men. The age-standardized prevalence of HFNEF for women and men was 5.1 % (95%CI 3.8-7.0 and 3.0 % (95%CI 2.1-4.5, respectively. Persons with CHF were more likely to have hypertension (PR = 3.4; 95%CI 1.6-7.3 or to have had a previous myocardial infarction (PR = 2.5, 95%CI 1.8-3.5. CONCLUSION: The prevalence of symptomatic CHF appears high in this population compared with other studies. While more women were affected by HFNEF than men, more male subjects suffered from HFREF. The high prevalence of symptomatic CHF seems likely to be mainly due to the high prevalence of cardiovascular risk factors in this population.

  19. The value of radionuclide angiography for risk assessment of patients following acute myocardial infarction

    International Nuclear Information System (INIS)

    Morris, K.G.

    1985-01-01

    Radionuclide angiography (RNA) is an accurate noninvasive method for the evaluation of left ventricular function at rest and exercise. Both the change in ejection fraction from rest to exercise and the exercise ejection fraction correlate with the severity of coronary artery disease and are more sensitive than ST-segment changes for detecting abnormalities due to exercise-induced myocardial ischemia. The amount of left ventricular dysfunction produced acutely by myocardial ischemia appears to vary linearly with the severity of ischemia produced. Thus rest and exercise RNA provide information noninvasively regarding both the severity of left ventricular dysfunction and the amount of potentially ischemic myocardium, two of the three major pathophysiologic mechanisms related to prognosis. It is reasonable to hypothesize that rest and exercise RNA may provide useful prognostic information concerning subsequent mortality and morbidity in survivors of acute myocardial infarction

  20. Comparison of left ventricular ejection fraction by 201Tl gated SPECT and gated blood pool scan

    International Nuclear Information System (INIS)

    Lau, W.F.E.; Kelly, M.J.; O'Donnell, M.; Kalff, V.; Van Every, B.

    2000-01-01

    Full text: The aim of this study was to evaluate left ventricular ejection fraction (LVEF) determination by the Germano 201 Tl gated-SPECT myocardial perfusion (TLGSMP) method using gated blood pool scintigraphy (GBPS) as a reference. 21 patients underwent both TLGSMP and GBPS within eight days of each other from June 1997 to Jan 2000. Acquisition of TLGSMP was performed on a GE Optima NX dual head camera using Tl-201 dose of 1.5MBq/Kg and imaging time of 45 cardiac cycles/step with 16 steps/90 Deg of rotation per detector. All LVEF results were determined using a GE Genie workstation. GBPS results were compared with TLGSMP results for LVEF obtained from the reinjection images using automated Germano processing, and from the stress images using automatic and manual processing. Duplicate automatic analysis by a second observer produced identical mean TLGSMP LVEF results (r = 0.99). Stress TLGSMP LVEF by the automatic and manual processing correlate well (r = 0.99) but the manual LVEF is significantly lower. In conclusion LVEF determination using TLGSMP is highly reproducible and is also accurate when applied to reinjection data. Both manual processing and the use of stress data lead to underestimation of LVEF. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. Automated determination of the right ventricular ejection fraction by digital processing of sup(81m)Kr scintigrams

    International Nuclear Information System (INIS)

    Elfner, R.; Vaknine, R.; Knapp, W.H.; Tillmanns, H.; Lorenz, W.J.

    1986-01-01

    A method is presented for the automated determination of the right ventricular ejection fraction (RVEF) by digital image processing of scintigrams obtained by intravenous infusion of Krypton 81m (sup(81m)Kr) dissolved in a glucose solution. End-diastolic and end-systolic sum pictures were computed by the addition of approximately 30-40 frames selected from the time-activity curve of a preliminary, manually drawn, right ventricular region of interest. After processing these two images with an adaptive Wiener filter, the right ventricular contour was determined by a recently developed algorithm using morphological and functional criteria. The RVEF was calculated for a series of 51 patients from the counts in the detected right ventricular regions in the end-diastolic and end-systolic sum images. In 16 patients without evidence of cardiopulmonary disease, the mean RVEF was 50+-6.1%. RVEF was significantly reduced in 18 patients with obstructive pulmonary disease (42+-6.5%) and in 17 patients with congestive cardiomyopathy (36+-7.1%). The correlation coefficient between two determinations of the RVEF was r=0.94. Through digital image processing, the determination of the RVEF by radioventriculography with sup(81m)Kr showed high reliability and reproducibility. (orig.)

  2. Ejection Tower Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Ejection Tower Facility's mission is to test and evaluate new ejection seat technology being researched and developed for future defense forces. The captive and...

  3. Repaired tetralogy of Fallot with coexisting unrepaired partial anomalous pulmonary venous connection is associated with diminished right ventricular ejection fraction and more severe right ventricular dilation

    International Nuclear Information System (INIS)

    Chan, Sherwin S.; Whitehead, Kevin K.; Kim, Timothy S.; Fu, Gregory L.; Fogel, Mark A.; Harris, Matthew A.; Keller, Marc S.

    2015-01-01

    There is an established association between tetralogy of Fallot and partial anomalous pulmonary venous connections. This association is important because surgically repaired tetralogy patients have increased risk of right heart failure. We hypothesize that partial anomalous venous connections increase right ventricular volumes and worsen right ventricular failure. We reviewed cardiac MRI exams performed at a tertiary pediatric hospital from January 2005 to January 2014. We identified patients with repaired tetralogy and unrepaired partial anomalous pulmonary venous connection. We used age- and gender-matched repaired tetralogy patients without partial anomalous pulmonary venous connection as controls. We analyzed the MRI results and surgical course and performed comparative statistics to identify group differences. There were eight patients with repaired tetralogy and unrepaired partial anomalous pulmonary venous connection and 16 controls. In all cases, the partial anomalous pulmonary venous connection was not detected on preoperative echocardiography. There were no significant differences in surgical course and body surface area between the two groups. Repaired tetralogy patients with unrepaired partial anomalous pulmonary venous connection showed significantly higher indexed right ventricular end diastolic volume (149 ± 33 mL/m 2 vs. 118 ± 30 mL/m 2 ), right ventricle to left ventricle size ratios (3.1 ± 1.3 vs. 1.9 ± 0.5) and a higher incidence of reduced right ventricular ejection fraction compared to controls (3/8 vs. 0/16). Repaired tetralogy of Fallot with unrepaired partial anomalous pulmonary venous connection is associated with reduced right ventricular ejection fraction and more significant right ventricular dilation. (orig.)

  4. Repaired tetralogy of Fallot with coexisting unrepaired partial anomalous pulmonary venous connection is associated with diminished right ventricular ejection fraction and more severe right ventricular dilation

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Sherwin S. [Children' s Mercy Hospital and Clinics, Department of Radiology, Kansas City, MO (United States); Whitehead, Kevin K.; Kim, Timothy S.; Fu, Gregory L.; Fogel, Mark A.; Harris, Matthew A. [Children' s Hospital of Philadelphia, Department of Cardiology, Philadelphia, PA (United States); Keller, Marc S. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2015-09-15

    There is an established association between tetralogy of Fallot and partial anomalous pulmonary venous connections. This association is important because surgically repaired tetralogy patients have increased risk of right heart failure. We hypothesize that partial anomalous venous connections increase right ventricular volumes and worsen right ventricular failure. We reviewed cardiac MRI exams performed at a tertiary pediatric hospital from January 2005 to January 2014. We identified patients with repaired tetralogy and unrepaired partial anomalous pulmonary venous connection. We used age- and gender-matched repaired tetralogy patients without partial anomalous pulmonary venous connection as controls. We analyzed the MRI results and surgical course and performed comparative statistics to identify group differences. There were eight patients with repaired tetralogy and unrepaired partial anomalous pulmonary venous connection and 16 controls. In all cases, the partial anomalous pulmonary venous connection was not detected on preoperative echocardiography. There were no significant differences in surgical course and body surface area between the two groups. Repaired tetralogy patients with unrepaired partial anomalous pulmonary venous connection showed significantly higher indexed right ventricular end diastolic volume (149 ± 33 mL/m{sup 2} vs. 118 ± 30 mL/m{sup 2}), right ventricle to left ventricle size ratios (3.1 ± 1.3 vs. 1.9 ± 0.5) and a higher incidence of reduced right ventricular ejection fraction compared to controls (3/8 vs. 0/16). Repaired tetralogy of Fallot with unrepaired partial anomalous pulmonary venous connection is associated with reduced right ventricular ejection fraction and more significant right ventricular dilation. (orig.)

  5. Calculation of left ventricular volume and ejection fraction from ECG-gated myocardial SPECT. Automatic detection of endocardial borders by threshold method

    International Nuclear Information System (INIS)

    Fukushi, Shoji; Teraoka, Satomi.

    1997-01-01

    A new method which calculate end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) of the left ventricle from myocardial short axis images of ECG-gated SPECT using 99m Tc myocardial perfusion tracer has been designed. Eight frames per cardiac cycle ECG-gated 180 degrees SPECT was performed. Threshold method was used to detect myocardial borders automatically. The optimal threshold was 45% by myocardial SPECT phantom. To determine if EDV, ESV and LVEF can also be calculated by this method, 12 patients were correlated ventriculography (LVG) for 10 days each. The correlation coefficient with LVG was 0.918 (EDV), 0.935 (ESV) and 0.900 (LVEF). This method is excellent at objectivity and reproductivity because of the automatic detection of myocardial borders. It also provides useful information on heart function in addition to myocardial perfusion. (author)

  6. Reduced ejection fraction heart failure – new data from multicenter studies and national registries regarding general and elderly populations: hopes and disappointments

    Directory of Open Access Journals (Sweden)

    Crișan S

    2018-04-01

    Full Text Available Simina Crişan,1,2 Lucian Petrescu,1,2 Mihai Andrei Lazăr,1,2 Cristina Văcărescu,1,2 Alina-Ramona Nicola,1 Dragoş Cozma,1,2 Cristian Mornoş,1,2 Constantin Tudor Luca1,2 1Cardiology Department, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania; 2Institute of Cardiovascular Diseases, Timisoara, Romania Abstract: The evaluation of patients diagnosed with impaired systolic function heart failure represents a great challenge, in both the general and elderly population. We consider that elderly patients are the most severely affected by this disease that represents the final impact of cardiovascular disease continuum. Cardiovascular diseases are associated with serious morbidity and mortality, and considerable health care costs related to diagnosis and treatment. In this report we discuss some controversies regarding methods of heart failure evaluation as well as therapeutic steps and devices, including: reparatory therapeutic steps and initiation of therapy with loop diuretics, inconsistent dose titration for angiotensin-converting enzyme inhibitors/angiotensin receptor blocker and beta blockers, as well as novel therapies, such as angiotensin receptor neprilysin inhibitor and treatments that directly improve cardiomyocyte function. We conclude that, beyond technical progress, which is raising the cost of therapy for patients with heart failure, more careful monitoring of patient progress through clinical and paraclinical control visits, both at medical facilities and at home, would have greater impact and be more cost-effective. Physical therapy and promoting emotional and psychological wellbeing, to maintain a positive state of mind, contribute substantially to the quality of life and life expectancy, and are most important in elderly people who are most affected by dramatic reductions in wellbeing. Unfortunately, for many patients with severe impairment of left ventricular ejection fraction, these goals and therapeutic

  7. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  8. Dietary Fat, Sugar Consumption, and Cardiorespiratory Fitness in Patients With Heart Failure With Preserved Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Salvatore Carbone, MS

    2017-10-01

    Full Text Available Heart failure with preserved ejection fraction (HFpEF is associated with obesity and, indirectly, with unhealthy diet. The role of dietary components in HFpEF is, however, largely unknown. In this study, the authors showed that in obese HFpEF patients, consumption of unsaturated fatty acids (UFA, was associated with better cardiorespiratory fitness, and UFA consumption correlated with better diastolic function and with greater fat-free mass. Similarly, mice fed with a high-fat diet rich in UFA and low in sugars had preserved myocardial function and reduced weight gain. Randomized clinical trials increasing dietary UFA consumption and reducing sugar consumption are warranted to confirm and expand our findings.

  9. Renal impairment and heart failure with preserved ejection fraction early post-myocardial infarction

    Science.gov (United States)

    Jorapur, Vinod; Lamas, Gervasio A; Sadowski, Zygmunt P; Reynolds, Harmony R; Carvalho, Antonio C; Buller, Christopher E; Rankin, James M; Renkin, Jean; Steg, Philippe Gabriel; White, Harvey D; Vozzi, Carlos; Balcells, Eduardo; Ragosta, Michael; Martin, C Edwin; Srinivas, Vankeepuram S; Wharton III, William W; Abramsky, Staci; Mon, Ana C; Kronsberg, Shari S; Hochman, Judith S

    2010-01-01

    AIM: To study if impaired renal function is associated with increased risk of peri-infarct heart failure (HF) in patients with preserved ejection fraction (EF). METHODS: Patients with occluded infarct-related arteries (IRAs) between 1 to 28 d after myocardial infarction (MI) were grouped into chronic kidney disease (CKD) stages based on estimated glomerular filtration rate (eGFR). Rates of early post-MI HF were compared among eGFR groups. Logistic regression was used to explore independent predictors of HF. RESULTS: Reduced eGFR was present in 71.1% of 2160 patients, with significant renal impairment (eGFR < 60 mL/min every 1.73 m2) in 14.8%. The prevalence of HF was higher with worsening renal function: 15.5%, 17.8% and 29.4% in patients with CKD stages 1, 2 and 3 or 4, respectively (P < 0.0001), despite a small absolute difference in mean EF across eGFR groups: 48.2 ± 10.0, 47.9 ± 11.3 and 46.2 ± 12.1, respectively (P = 0.02). The prevalence of HF was again higher with worsening renal function among patients with preserved EF: 10.1%, 13.6% and 23.6% (P < 0.0001), but this relationship was not significant among patients with depressed EF: 27.1%, 26.2% and 37.9% (P = 0.071). Moreover, eGFR was an independent correlate of HF in patients with preserved EF (P = 0.003) but not in patients with depressed EF (P = 0.181). CONCLUSION: A significant proportion of post-MI patients with occluded IRAs have impaired renal function. Impaired renal function was associated with an increased rate of early post-MI HF, the association being strongest in patients with preserved EF. These findings have implications for management of peri-infarct HF. PMID:20885993

  10. Determination of right ventricular ejection fraction in children with cystic fibrosis, using krypton-81m

    International Nuclear Information System (INIS)

    Piepsz, A.; Ham, H.R.; Millet, E.; Dab, I.

    1984-01-01

    The diagnosis of cor pulmonale and incipient heart failure remains difficult to assess in cystic fibrosis (CF) on the basis of the clinical as well as the biological parameters. The measurement of the right ventricular ejection fraction has been facilitated these last years by the introduction of the radionuclide methods. Methodological difficulties are however encountered when Tc-99m RBC are used, and are mainly related to heart chambers superposition (equilibrium method) or the low count density (first pass method). Few papers have been published on RVEF in cystic fibrosis and the results are somewhat contradictory. The authors have recently introduced a new method for the determination of RVEF, using equilibrium study during continuous injection of Kr-81m in glucose solution. This method offers several advantages related to an increased accuracy and a favorable dosimetry. In 25 patients aged 2 to 23 years with CF, one or more RVEF studies were performed. The severity of the disease was evaluated on the basis of the clinical Schwachman score, the lung function tests, the ventilation scan and the pa02. RVEF tended to decrease with the progression of the lung disease, although, owing to the spread of the results, no RVEF could be predicted on the basis of the other parameters. The decrease of RVEF in patients with advanced lung disease was moderate and terminal lung disease was sometimes associated with normal right heart contractility

  11. Validity of automated measurement of left ventricular ejection fraction and volume using the Philips EPIQ system.

    Science.gov (United States)

    Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia

    2017-11-01

    To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.

  12. Radionuclide ventriculographic evaluation of exercised left ventricular performance in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Fujii, Yusuke; Hara, Fumio

    1991-01-01

    Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30∼70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4±9.8% (mean±SD) to 60.3±9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3±8.4 to 63.0±11.4 (p -1 ) vs -2.66±0.52] and during dynamic exercise [-3.25±0.74 vs -3.23±0.90]. Time to end-systole were similar in both groups at rest [315±42 (ms) vs 309±42] and during dynamic exercise [258±37 vs 262±37]. The resting peak filling rates were similar in both groups [2.27±0.62 (s -1 ) vs 2.45±0.58], and the peak filling rates increased (p 1c in the diabetic patients. These results suggest that diabetic patients have less cardiac reserved performance. (author)

  13. The Benefits of Exercise Training on Aerobic Capacity in Patients with Heart Failure and Preserved Ejection Fraction.

    Science.gov (United States)

    do Prado, Danilo Marcelo Leite; Rocco, Enéas Antônio

    2017-01-01

    Heart failure with preserved ejection fraction (HFpEF) is defined as an inability of the ventricles to optimally accept blood from atria with blunted end- diastolic volume response by limiting the stroke volume and cardiac output. The HEpEF prevalence is higher in elderly and women and may be associated to hypertension, diabetes mellitus and atrial fibrillation. Severe exercise intolerance, manifested by dyspnea and fatigue during physical effort is the important chronic symptom in HFpEF patients, in which is the major determinant of their reduced quality of life. In this sense, several studies demonstrated reduced aerobic capacity in terms of lower peak oxygen consumption (peak VO 2 ) in patients with HFpEF. In addition, the lower aerobic capacity observed in HFpEF may be due to impaired both convective and diffusive O 2 transport (i.e. reduced cardiac output and arteriovenous oxygen difference, respectively).Exercise training program can help restore physiological function in order to increase aerobic capacity and improve the quality of life in HFpEF patients. Therefore, the primary purpose of this chapter was to clarify the physiological mechanisms associated with reduced aerobic capacity in HFpEF patients. Secondly, special focus was devoted to show how aerobic exercise training can improve aerobic capacity and quality of life in HFpEF patients.

  14. Creation of a restrictive atrial communication in heart failure with preserved and mid-range ejection fraction: effective palliation of left atrial hypertension and pulmonary congestion.

    Science.gov (United States)

    Bauer, Anna; Khalil, Markus; Lüdemann, Monika; Bauer, Jürgen; Esmaeili, Anoosh; De-Rosa, Roberta; Voelkel, Norbert F; Akintuerk, Hakan; Schranz, Dietmar

    2018-04-16

    Left atrial decompression is considered in patients with symptomatic heart failure with preserved ejection fraction (HFpEF). We aimed to evaluate the feasibility and efficacy of transcatheter generation of a restrictive atrial septum communication to manage HFpEF from infancy to adulthood with cardiomyopathy and congenital heart defect. From June 2009 to December 2016, 24 patients (50% with an age less than 16 years) with HFpEF were palliated; NYHA-/Ross class IV (n = 10); median systemic ventricular ejection fraction 64 (range 35-78) %. Cardiomyopathy was classified as a restrictive (n = 4) or hypertrophic (n = 2). (75% related to congenital heart defects) Three patients had a systemic right ventricle; in the majority of patients, HFpEF was associated to complex congenital heart defects (n = 18). Mean pulmonary arterial pressures (PAP systolic/diastolic) were 56/28 (± 24/13), left atrial pressures (LAP, v-, a-wave, mean) 26/25/20 (± 7/10/6). Trans-septal puncture was used in 22 patients; foramen ovale dilatation in 2 patients. Median balloon size was 12 (range 6-18) mm; procedure time including diagnostic measures 125 (83-221) min. No procedural death or complications were observed. Mean LA-pressures decreased significantly to 19/19/15 ± 6/8/5 mmHg (p = 0.05); median brain natriuretic peptide (BNP) decreased from 392 (range 93-4401) pg/ml median BNP to 314 (range 61-1544) pg/ml (p = 0.05). Three patients died; one patient received orthotopic heart and one patient a heart-lung transplantation. No patient required so far an assist device. Clinical improvement occurred in all patients, in some after additional surgical or interventional approach. Transcatheter LA decompression is an age-independent, effective palliation treating patients with HFpEF.

  15. Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging

    Science.gov (United States)

    Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman

    2017-06-01

    ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.

  16. Efficacy and safety of sacubitril/valsartan (LCZ696) in Japanese patients with chronic heart failure and reduced ejection fraction: Rationale for and design of the randomized, double-blind PARALLEL-HF study.

    Science.gov (United States)

    Tsutsui, Hiroyuki; Momomura, Shinichi; Saito, Yoshihiko; Ito, Hiroshi; Yamamoto, Kazuhiro; Ohishi, Tomomi; Okino, Naoko; Guo, Weinong

    2017-09-01

    The prognosis of heart failure patients with reduced ejection fraction (HFrEF) in Japan remains poor, although there is growing evidence for increasing use of evidence-based pharmacotherapies in Japanese real-world HF registries. Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor shown to reduce mortality and morbidity in the recently completed largest outcome trial in patients with HFrEF (PARADIGM-HF trial). The prospectively designed phase III PARALLEL-HF (Prospective comparison of ARNI with ACE inhibitor to determine the noveL beneficiaL trEatment vaLue in Japanese Heart Failure patients) study aims to assess the clinical efficacy and safety of LCZ696 in Japanese HFrEF patients, and show similar improvements in clinical outcomes as the PARADIGM-HF study enabling the registration of LCZ696 in Japan. This is a multicenter, randomized, double-blind, parallel-group, active controlled study of 220 Japanese HFrEF patients. Eligibility criteria include a diagnosis of chronic HF (New York Heart Association Class II-IV) and reduced ejection fraction (left ventricular ejection fraction ≤35%) and increased plasma concentrations of natriuretic peptides [N-terminal pro B-type natriuretic peptide (NT-proBNP) ≥600pg/mL, or NT-proBNP ≥400pg/mL for those who had a hospitalization for HF within the last 12 months] at the screening visit. The study consists of three phases: (i) screening, (ii) single-blind active LCZ696 run-in, and (iii) double-blind randomized treatment. Patients tolerating LCZ696 50mg bid during the treatment run-in are randomized (1:1) to receive LCZ696 100mg bid or enalapril 5mg bid for 4 weeks followed by up-titration to target doses of LCZ696 200mg bid or enalapril 10mg bid in a double-blind manner. The primary outcome is the composite of cardiovascular death or HF hospitalization and the study is an event-driven trial. The design of the PARALLEL-HF study is aligned with the PARADIGM-HF study and aims to assess

  17. Postoperative Functional Outcome After Off-Pump Versus On-Pump Coronary Artery Bypass Grafting Using Gated Myocardial SPECT: A Comparison by Propensity Score Analysis

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Paeng, Jin Chul; Lee, Dong Soo; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul; Kang, Won Jun

    2010-01-01

    We evaluated the short-term and mid-term differences in perfusion and function after off-pump and on-pump coronary artery bypass grafting (CABG) using gated myocardial single photon emission computed tomography. A total of 70 patients with coronary artery disease who underwent CABG were included based on the propensity score matching results from 165 patients. Thirty-five patients underwent off-pump and 35 patients on-pump CABG. Rest 201 TI/dipyridamole stress 99m Tc-methoxyisobutylisonitrile gated single photon emission computed thermographs were performed preoperatively and postoperatively at short-term (103±23 days after surgery) and mid-term follow-up (502±111 days after surgery). Changes in left ventricular ejection fraction, end systolic volume, stress and rest segmental perfusion, and segmental wall thickening were compared between the two groups. The segments with preoperative rest 201 T1 uptake under 60% of maximum uptake were included in the segmental analysis. Left ventricular ejection fraction (P=0.001) and end systolic volume (P=0.008) showed significant improvement in both groups. There were no significant short-term and mid-term differences between the two groups in terms of left ventricular ejection fraction (P=0.309) and end systolic volume (P=0.938). Likewise, segmental rest (P=0.178) and stress perfusion (P=0.071), and systolic wall thickening (P=0.241) showed significant improvement in both groups with similar time courses. Off-pump CABG resulted in significant improvements in left ventricular ejection fraction, end systolic volume, and regional myocardial perfusion and function that are comparable to on-pump CABG at short-term and mid-term. Gated myocardial SPECT successfully revealed that off-pump CABG is as good as on-pump CABG from the viewpoint of myocardial perfusion and function.

  18. Effects of an interatrial shunt on rest and exercise hemodynamics

    DEFF Research Database (Denmark)

    Kaye, David; Shah, Sanjiv J; Borlaug, Barry A

    2014-01-01

    BACKGROUND: A treatment based on an interatrial shunt device has been proposed for counteracting elevated pulmonary capillary wedge pressure (PCWP) in patients with heart failure and mildly reduced or preserved ejection fraction (HFpEF). We tested the theoretical hemodynamic effects of this appro...

  19. Echocardiographic right ventricle longitudinal contraction indices cannot predict ejection fraction in post-operative Fallot children.

    Science.gov (United States)

    Bonnemains, Laurent; Stos, Bertrand; Vaugrenard, Thibaud; Marie, Pierre-Yves; Odille, Freddy; Boudjemline, Younes

    2012-03-01

    To examine in a population of post-operative tetralogy of Fallot patients, the correlation between right ventricle (RV) ejection fractions (EF) computed from magnetic resonance imaging (MRI) and three echocardiographic indices of RV function: TAPSE, longitudinal strain and strain rate. Indeed, these patients present a pulmonary regurgitation which is responsible for progressive dilatation of the RV. An echocardiographic assessment of the RV function would be very useful in determining the timing of pulmonary revalvulation for Fallot patients. However, these indices are generally based on the ventricle contraction in the long axis direction which is impaired in this population and does not seem to correlate with the EF. Thirty-five post-operative tetralogy of Fallot patients and 20 patients with normal RVs were included. In both groups, RVEF, assessed by MRI, was compared with the three echocardiographic indices. Longitudinal strain and strain rates were computed both on the free wall and on the whole RV. No correlation was found between the echocardiographic indices and the MRI EF in our Fallot population. The accuracy of those indices as a diagnostic test of an altered RV was low with Younden's indices varying from -0.18 to 0.5 and areas under the Receiver Operating Characterictic (ROC) curves equal to 0.54 for tricuspid annulus plane systolic excursion, 0.59-0.62 for strain and 0.57-0.63 for strain rate. Three conventional echocardiographic indices based on RV longitudinal contraction failed to assess the EF in our population of post-operative tetralogy of Fallot patients.

  20. Comparison of clinical profile and management of outpatients with heart failure with reduced left ventricular ejection fraction treated by general practitioners and cardiologists in contemporary Poland: the results from the DATA-HELP registry.

    Science.gov (United States)

    Jankowska, Ewa A; Kalicinska, Elzbieta; Drozd, Marcin; Kurian, Beata; Banasiak, Waldemar; Ponikowski, Piotr

    2014-10-20

    We sought to determine and compare clinical profile and management of outpatients with heart failure with reduced ejection fraction (HFREF) treated by cardiologists and general practitioners (GPs) in Poland. All the 790 randomly selected cardiologists and GPs in the DATA-HELP registry, which included 5563 patients, filled out questionnaires about 10 consecutive outpatients with HFREF. Outpatients managed by GPs were older (69±10 vs 66±12 years), and the prevalence of men was less marked (58% vs 67%). They also had higher left ventricular ejection fraction (38±6% vs 35±8%) and had more pulmonary congestion (63% vs 49%) and peripheral oedema (66% vs 51%), compared with those treated by cardiologists (all p0.2) and digoxin (20% vs 21%, p>0.2) by GPs and cardiologists was similar. In contemporary Poland, most outpatients with HFREF receive drugs that improve survival and undergo revascularisation procedures, although devices are rare, but the clinical profiles and management of those treated by GPs and cardiologists differ. Outpatients treated by GPs are older and have more co-morbidities. Outpatients treated by cardiologists more commonly receive β-blocker, MRA, ICD, and CRT, and undergo coronary revascularisations. Copyright © 2014. Published by Elsevier Ireland Ltd.

  1. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  2. Substituição isolada da valva aórtica em pacientes com função ventricular deprimida Aortic valve replacement in patients with depressed left ventricular ejection fraction

    Directory of Open Access Journals (Sweden)

    Gilberto Venossi Barbosa

    1989-12-01

    Full Text Available Para avaliar o valor prognóstico da fração de ejeção do ventrículo esquerdo, entre 210 pacientes com lesões da valva aórtica operados, consecutivamente, entre maio de 1981 e outubro de 1988 e que receberam as próteses Omniscience e Meditronic-Hall, foram selecionados 112 e divididos, de acordo com a fração de ejeção do ventrículo esquerdo, em dois grupos: o G1 = FE > 40%, ficou com 52 pacientes com médias de idade 39 ± 12 anos, FE = 58 ± 10% e classe funcional (NYHA = 2,8; o GE = FE To evaluate the prognostic value of resting left ventricular ejection fraction (LVEF a series of 210 consecutive patients with aortic valve disease operated upon between May 1981 and October 1988 was studied retrospectively. All patients had their aortic valve replaced by Omniscience or Meditronic prosthesis; 112 formed the study group because they have complete follow up and cineangiocardiographic data. Based on pre-operatory left ventricular ejection fraction the patients were divided in two groups: Group 1 = 52 patients with LVEF > 40%, 39 ± 12 years, NYHA functional class 2.8, and EF 58 ± 10%. Group 2 = 60 patients with LVEF < 40, 48 ± 17 years, NYHA functional class 3.6, and LVEF of 27 ± 12%. During surgery moderate hypothermia and hemodilution were utilized, with dubble oxygenator and cardioplegia With St. Thomas cardioplegic solution. Mean extracorporeal circulation and cardiac arrest time were respectively 82 ± 18 and 49 ± 7 minutes in Group 1 and 96 ± 11 and 55 ± 6 minutes in Group 2. The size of the prosthesis were 25.2 ± 1.8 mm in Group 1. The short term mortality was 3.8% in Group 1 and 5.8 in Group 2. The long-term mortality was 4.0% in Group 1 and 8.7% in Group 2. In Group 1 there was a significant association between mortality and left ventricular systolic function. In the follow-up evaluation, among patients in Group 1, 65% were in class I, 28% were in functional class II, 5% in class III, and 2% in class IV. Among patients

  3. Comorbidities, risk factors and outcomes in patients with heart failure and an ejection fraction of more than or equal to 40% in primary care- and hospital care-based outpatient clinics.

    Science.gov (United States)

    Eriksson, B; Wändell, P; Dahlström, U; Näsman, P; Lund, L H; Edner, M

    2018-06-01

    The aim of this study is to describe patients with heart failure and an ejection fraction (EF) of more than or equal to 40%, managed in both Primary- and Hospital based outpatient clinics separately with their prognosis, comorbidities and risk factors. Further to compare the heart failure medication in the two groups. We used the prospective Swedish Heart Failure Registry to include 9654 out-patients who had HF and EF ≥40%, 1802 patients were registered in primary care and 7852 in hospital care. Descriptive statistical tests were used to analyze base line characteristics in the two groups and multivariate logistic regression analysis to assess mortality rate in the groups separately. The prospective Swedish Heart Failure Registry. Patients with heart failure and an ejection fraction (EF) of more than or equal to 40%. Comorbidities, risk factors and mortality. Mean-age was 77.5 (primary care) and 70.3 years (hospital care) p care group having more atrial fibrillation, hypertension, ischemic heart disease and COPD. According to the multivariate logistic regression analysis smoking, COPD and diabetes were the most important independent risk factors in the primary care group and valvular disease in the hospital care group. All-cause mortality during mean follow-up of almost 4 years was 31.5% in primary care and 27.8% in hospital care. One year-mortality rates were 7.8%, and 7.0% respectively. Any co-morbidity was noted in 97% of the HF-patients with an EF of more than or equal to 40% managed at primary care based out-patient clinics and these patients had partly other independent risk factors than those patients managed in hospital care based outpatients clinics. Our results indicate that more attention should be payed to manage COPD in the primary care group. KEY POINTS 97% of heart failure patients with an ejection fraction of more than or equal to 40% managed at primary care based out-patient clinics had any comorbidity. Patients in primary care had partly other

  4. Left ventricular ejection fraction and volumes as measured by 3D echocardiography and ultrafast computed tomography

    International Nuclear Information System (INIS)

    Vieira, Marcelo Luiz Campos; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Passos, Rodrigo B.D.; Funari, Marcelo B. G.; Fischer, Claudio H.; Morhy, Samira S.

    2009-01-01

    Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Methods: Thirty nine consecutive patients (27 men, mean age of 57+- 12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p 5 .58)%; end-diastolic volume ranged from 49.6 to 178.2 (87+-27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1+-13.6) ml. CT scan measurements: LVEF ranged from 53 to 86% (67.8+-7.78); end-diastolic volume ranged from 51 to 186 (106.5+-30.3) ml; end-systolic volume ranged from 7 to 72 (35.5+-13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95% CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95% CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95% CI 0.6673 to 0.8975). Conclusion: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series. (author)

  5. Cost-effectiveness of sacubitril/valsartan in chronic heart-failure patients with reduced ejection fraction.

    Science.gov (United States)

    Ademi, Zanfina; Pfeil, Alena M; Hancock, Elizabeth; Trueman, David; Haroun, Rola Haroun; Deschaseaux, Celine; Schwenkglenks, Matthias

    2017-11-29

    We aimed to assess the cost effectiveness of sacubitril/valsartan compared to angiotensin-converting enzyme inhibitors (ACEIs) for the treatment of individuals with chronic heart failure and reduced-ejection fraction (HFrEF) from the perspective of the Swiss health care system. The cost-effectiveness analysis was implemented as a lifelong regression-based cohort model. We compared sacubitril/valsartan with enalapril in chronic heart failure patients with HFrEF and New York-Heart Association Functional Classification II-IV symptoms. Regression models based on the randomised clinical phase III PARADIGM-HF trials were used to predict events (all-cause mortality, hospitalisations, adverse events and quality of life) for each treatment strategy modelled over the lifetime horizon, with adjustments for patient characteristics. Unit costs were obtained from Swiss public sources for the year 2014, and costs and effects were discounted by 3%. The main outcome of interest was the incremental cost-effectiveness ratio (ICER), expressed as cost per quality-adjusted life years (QALYs) gained. Deterministic sensitivity analysis (DSA) and scenario and probabilistic sensitivity analysis (PSA) were performed. In the base-case analysis, the sacubitril/valsartan strategy showed a decrease in the number of hospitalisations (6.0% per year absolute reduction) and lifetime hospital costs by 8.0% (discounted) when compared with enalapril. Sacubitril/valsartan was predicted to improve overall and quality-adjusted survival by 0.50 years and 0.42 QALYs, respectively. Additional net-total costs were CHF 10 926. This led to an ICER of CHF 25 684. In PSA, the probability of sacubitril/valsartan being cost-effective at thresholds of CHF 50 000 was 99.0%. The treatment of HFrEF patients with sacubitril/valsartan versus enalapril is cost effective, if a willingness-to-pay threshold of CHF 50 000 per QALY gained ratio is assumed.

  6. Peak Exercise Oxygen Uptake Predicts Recurrent Admissions in Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Palau, Patricia; Domínguez, Eloy; Núñez, Eduardo; Ramón, José María; López, Laura; Melero, Joana; Sanchis, Juan; Bellver, Alejandro; Santas, Enrique; Bayes-Genis, Antoni; Chorro, Francisco J; Núñez, Julio

    2018-04-01

    Heart failure with preserved ejection fraction (HFpEF) is a highly prevalent syndrome with an elevated risk of morbidity and mortality. To date, there is scarce evidence on the role of peak exercise oxygen uptake (peak VO 2 ) for predicting the morbidity burden in HFpEF. We sought to evaluate the association between peak VO 2 and the risk of recurrent hospitalizations in patients with HFpEF. A total of 74 stable symptomatic patients with HFpEF underwent a cardiopulmonary exercise test between June 2012 and May 2016. A negative binomial regression method was used to determine the association between the percentage of predicted peak VO 2 (pp-peak VO 2 ) and recurrent hospitalizations. Risk estimates are reported as incidence rate ratios. The mean age was 72.5 ± 9.1 years, 53% were women, and all patients were in New York Heart Association functional class II to III. Mean peak VO 2 and median pp-peak VO 2 were 10 ± 2.8mL/min/kg and 60% (range, 47-67), respectively. During a median follow-up of 276 days [interquartile range, 153-1231], 84 all-cause hospitalizations in 31 patients (41.9%) were registered. A total of 15 (20.3%) deaths were also recorded. On multivariate analysis, accounting for mortality as a terminal event, pp-peak VO 2 was independently and linearly associated with the risk of recurrent admission. Thus, and modeled as continuous, a 10% decrease of pp-peak VO 2 increased the risk of recurrent hospitalizations by 32% (IRR, 1.32; 95%CI, 1.03-1.68; P = .028). In symptomatic elderly patients with HFpEF, pp-peak VO 2 predicts all-cause recurrent admission. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  7. Low diastolic blood pressure and adverse outcomes in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Tsujimoto, Tetsuro; Kajio, Hiroshi

    2018-07-15

    It remains unknown whether a low diastolic blood pressure (DBP) increases the risks of cardiovascular events and death in patients with heart failure with preserved ejection fraction (HFpEF). We used data from the TOPCAT trial. The primary outcome was a composite of all-cause death, non-fatal myocardial infarction, non-fatal stroke, or hospitalization for heart failure. Hazard ratios (HRs) were analyzed for DBPs of <60, 60-69, 70-79, and ≥90 mm Hg in comparison with a DBP of 80-89 mm Hg using multivariable Cox proportional hazard models. This study included 3417 patients with HFpEF who had a controlled blood pressure. In the mean follow-up period of 3.0 years, 881 patients experienced at least one confirmed primary outcome event. Compared with patients with a DBP of 80-89 mm Hg, the adjusted HRs for primary outcome events were significantly higher in those with DBPs of <60 mm Hg (HR: 2.19 [95% confidence interval,1.72-2.78]) and 60-69 mm Hg (HR: 1.52 [1.23-1.87]). Similarly, the adjusted HRs for all-cause death, major cardiovascular events, and hospitalization for heart failure, but not stroke, were significantly higher in patients with a DBP of <70 mm Hg. A relationship between a low DBP and adverse outcomes was found in HFpEF patients with a systolic blood pressure of ≥120 mm Hg; however, a low systolic blood pressure with a DBP of ≥70 mm Hg was not associated with these event risks. A low DBP increased the risks of adverse outcomes in patients with HFpEF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  8. On the hypothesis of hyperimpact-induced ejection of asteroid-size bodies from Earth-type planets.

    Science.gov (United States)

    Drobyshevski, E. M.

    During the last two decades a number of facts have brought to life a seemingly fantastic idea of ejection of large rocky fragments from planets into space, like for example SNC meteorites or many-km-size fragments of Vesta. The theoretical description of impact processes of this ejection lags behind. Considerable efforts have been spent to show the possibility of ejection of bodies several meters in size from large impact craters on Mars. In general, the possibility of impact self-destruction of inner planets may drastically alter traditional models of the origin of the Solar System. However, non-destructive gasdynamic ejection of large fragments from planets requires a mechanism for fast conversion of shock-wave energy into heat. The extrapolation of data from laboratory impact experiments (≡10 kJ) and nuclear explosions (<1 Mt TNT) in order to describe hyperimpact processes with 105 - 106 Mt TNT energies can hardly be justified, that is why these calculations give relatively small gas production and, consequently, small velocities of fragment ejection from impact craters. It is predicted that at such energies some instabilities may lead to formation of new dissipation channels, that would increase the part of the overheated gas fraction in the hyperimpact ejection products. This would eliminate numerous contradictions in the impact history of planets, asteroids, meteorites etc.

  9. Diagnostic and Prognostic Value of CMR T1-Mapping in Patients With Heart Failure and Preserved Ejection Fraction.

    Science.gov (United States)

    Rommel, Karl-Philipp; Lücke, Christian; Lurz, Philipp

    2017-10-01

    Heart failure with preserved ejection fraction (HFpEF) presents a major challenge in modern cardiology. Although this syndrome is of increasing prevalence and is associated with unfavorable outcomes, treatment trials have failed to establish effective therapies. Currently, solutions to this dilemma are being investigated, including categorizing and characterizing patients more diversely to individualize treatment. In this regard, new imaging techniques might provide important information. Diastolic dysfunction is a diagnostic and pathophysiological cornerstone in HFpEF and is believed to be caused by systemic inflammation with the development of interstitial myocardial fibrosis and myocardial stiffening. Cardiac magnetic resonance (CMR) T 1 -mapping is a novel tool, which allows noninvasive quantification of the extracellular space and diffuse myocardial fibrosis. This review provides an overview of the potential of myocardial tissue characterization with CMR T 1 mapping in HFpEF patients, outlining its diagnostic and prognostic implications and discussing future directions. We conclude that CMR T 1 mapping is potentially an effective tool for patient characterization in large-scale epidemiological, diagnostic, and therapeutic HFpEF trials beyond traditional imaging parameters. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Left ventricular ejection fraction to predict early mortality in patients with non-ST-segment elevation acute coronary syndromes.

    Science.gov (United States)

    Bosch, Xavier; Théroux, Pierre

    2005-08-01

    Improvement in risk stratification of patients with non-ST-segment elevation acute coronary syndrome (ACS) is a gateway to a more judicious treatment. This study examines whether the routine determination of left ventricular ejection fraction (EF) adds significant prognostic information to currently recommended stratifiers. Several predictors of inhospital mortality were prospectively characterized in a registry study of 1104 consecutive patients, for whom an EF was determined, who were admitted for an ACS. Multiple regression models were constructed using currently recommended clinical, electrocardiographic, and blood marker stratifiers, and values of EF were incorporated into the models. Age, ST-segment shifts, elevation of cardiac markers, and the Thrombolysis in Myocardial Infarction (TIMI) risk score all predicted mortality (P model improved the prediction of mortality (C statistic 0.73 vs 0.67). The odds of death increased by a factor of 1.042 for each 1% decrement in EF. By receiver operating curves, an EF cutoff of 48% provided the best predictive value. Mortality rates were 3.3 times higher within each TIMI risk score stratum in patients with an EF of 48% or lower as compared with those with higher. The TIMI risk score predicts inhospital mortality in a broad population of patients with ACS. The further consideration of EF adds significant prognostic information.

  11. Analysis of blood pressure signal in patients with different ventricular ejection fraction using linear and non-linear methods.

    Science.gov (United States)

    Arcentales, Andres; Rivera, Patricio; Caminal, Pere; Voss, Andreas; Bayes-Genis, Antonio; Giraldo, Beatriz F

    2016-08-01

    Changes in the left ventricle function produce alternans in the hemodynamic and electric behavior of the cardiovascular system. A total of 49 cardiomyopathy patients have been studied based on the blood pressure signal (BP), and were classified according to the left ventricular ejection fraction (LVEF) in low risk (LR: LVEF>35%, 17 patients) and high risk (HR: LVEF≤35, 32 patients) groups. We propose to characterize these patients using a linear and a nonlinear methods, based on the spectral estimation and the recurrence plot, respectively. From BP signal, we extracted each systolic time interval (STI), upward systolic slope (BPsl), and the difference between systolic and diastolic BP, defined as pulse pressure (PP). After, the best subset of parameters were obtained through the sequential feature selection (SFS) method. According to the results, the best classification was obtained using a combination of linear and nonlinear features from STI and PP parameters. For STI, the best combination was obtained considering the frequency peak and the diagonal structures of RP, with an area under the curve (AUC) of 79%. The same results were obtained when comparing PP values. Consequently, the use of combined linear and nonlinear parameters could improve the risk stratification of cardiomyopathy patients.

  12. Proton ejection project for Saturne

    International Nuclear Information System (INIS)

    Bronca, G.; Gendreau, G.

    1959-01-01

    The reasons for choosing the ejection system are given. The characteristics required for the ejected beam are followed by a description of the ejection process, in chronological order from the viewpoint of the protons: movement of the particles, taking into account the various elements which make up the system (internal magnet, external magnet, quadrupoles, ejection correction coils, thin and thick cables,...) and specification of these elements. Then follows an estimation of the delay in manufacture and the cost of the project. Finally, the characteristics of the magnets and quadrupoles are listed in an appendix. (author) [fr

  13. Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe

    International Nuclear Information System (INIS)

    Schneider, J.; Berger, H.J.; Sands, M.J.; Lachman, A.B.; Zaret, B.L.

    1983-01-01

    There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r . 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients

  14. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Medicare Expenditures by Race/Ethnicity After Hospitalization for Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Ziaeian, Boback; Heidenreich, Paul A; Xu, Haolin; DeVore, Adam D; Matsouaka, Roland A; Hernandez, Adrian F; Bhatt, Deepak L; Yancy, Clyde W; Fonarow, Gregg C

    2018-05-01

    The purpose of this study was to analyze cumulative Medicare expenditures at index admission and after discharge by race or ethnicity. Heart failure with preserved ejection fraction (HFpEF) is a growing proportion of heart failure (HF) admissions. Research on health care expenditures for patients with HFpEF is limited. Records of patients discharged from the Get With The Guidelines-Heart Failure registry between 2006 and 2014 were linked to Medicare data. The primary outcome was unadjusted payments for acute care services. Comparisons between race/ethnic groups were made using generalized linear mixed models. Cost ratios were reported by race/ethnicity, and adjustments were made sequentially for patient characteristics, hospital factors, and regional socioeconomic status. Median Medicare costs for index hospitalizations were $7,241 for the entire cohort, $7,049 for whites, $8,269 for blacks, $8,808 for Hispanics, $8,477 for Asians, and $8,963 for other races. Median costs at 30 days for readmitted patients were $9,803 and $17,456 for the entire cohort at 1-year. No significant differences were seen in index admission cost ratios by race/ethnicity. At 30 days among readmitted patients, costs were 9% higher (95% confidence interval [CI]: 1% to 17%; p = 0.020) for blacks in the fully adjusted model than whites. At 1 year, costs were 14% higher (95% CI: 9% to 18%; p expenditures were noted. Minority patients with HFpEF have greater acute care service costs. Further research of improving care delivery is needed to reduce acute care use for vulnerable populations. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients.

    Science.gov (United States)

    Yoneyama, Hiroto; Shibutani, Takayuki; Konishi, Takahiro; Mizutani, Asuka; Hashimoto, Ryosuke; Onoguchi, Masahisa; Okuda, Koichi; Matsuo, Shinro; Nakajima, Kenichi; Kinuya, Seigo

    2017-09-01

    The IQ•SPECT system, which is equipped with multifocal collimators ( SMART ZOOM) and uses ordered-subset conjugate gradient minimization as the reconstruction algorithm, reduces the acquisition time of myocardial perfusion imaging compared with conventional SPECT systems equipped with low-energy high-resolution collimators. We compared the IQ•SPECT system with a conventional SPECT system for estimating left ventricular ejection fraction (LVEF) in patients with a small heart (end-systolic volume IQ•SPECT. End-systolic volume, end-diastolic volume, and LVEF were calculated using quantitative gated SPECT (QGS) and cardioREPO software. We compared the LVEF from gated myocardial perfusion SPECT to that from echocardiographic measurements. Results: End-diastolic volume, end-systolic volume, and LVEF as obtained from conventional SPECT, IQ•SPECT, and echocardiography showed a good to excellent correlation regardless of whether they were calculated using QGS or using cardioREPO. Although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (65.4% ± 13.8% vs. 68.4% ± 15.2%) ( P = 0.0002), LVEF calculated using cardioREPO did not (69.5% ± 10.6% vs. 69.5% ± 11.0%). Likewise, although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (75.0 ± 9.6 vs. 79.5 ± 8.3) ( P = 0.0005), LVEF calculated using cardioREPO did not (72.3% ± 9.0% vs. 74.3% ± 8.3%). Conclusion: In small-heart patients, the difference in LVEF between IQ•SPECT and conventional SPECT was less when calculated using cardioREPO than when calculated using QGS. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Peak oxygen uptake and left ventricular ejection fraction, but not depressive symptoms, are associated with cognitive impairment in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Steinberg G

    2011-12-01

    Full Text Available Gerrit Steinberg1,2*, Nicole Lossnitzer2*, Dieter Schellberg2, Thomas Mueller-Tasch2, Carsten Krueger3, Markus Haass4, Karl Heinz Ladwig5, Wolfgang Herzog2, Jana Juenger21University Hospital of Psychiatry, University of Bern, Bern, Switzerland; 2Department of Psychosomatic and General Internal Medicine, Medical Hospital, University of Heidelberg, Heidelberg, 3Department of Cardiology, Josefs Hospital, Heidelberg, 4Department of Cardiology, Theresien Hospital, Mannheim, 5Institute of Epidemiology, German Research Center for Environmental Health, Munich, Germany*both authors contributed equally to this paperBackground: The aim of the present study was to assess cognitive impairment in patients with chronic heart failure (CHF and its associations with depressive symptoms and somatic indicators of illness severity, which is a matter of controversy.Methods and results: Fifty-five patients with CHF (mean age 55.3 ± 7.8 years; 80% male; New York Heart Association functional class I–III underwent assessment with an expanded neuropsychological test battery (eg, memory, complex attention, mental flexibility, psychomotor speed to evaluate objective and subjective cognitive impairment. Depressive symptoms were assessed using the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (SCID and a self-report inventory (Hospital Anxiety and Depression Scale [HADS]. A comprehensive clinical dataset, including left ventricular ejection fraction, peak oxygen uptake, and a 6-minute walk test, was obtained for all patients. Neuropsychological functioning revealed impairment in 56% of patients in at least one measure of our neuropsychological test battery. However, the Mini Mental State Examination (MMSE could only detect cognitive impairment in 1.8% of all patients, 24% had HADS scores indicating depressive symptoms, and 11.1% met SCID criteria for a depressive disorder. No significant association was found

  18. Measurement of left ventricular ejection fraction with ionic sup(113m)In and a cardiac probe

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Harrison, K.S.; Wagner, H.N. Jr.

    1982-09-01

    Left ventricular ejection fraction (LVEF) was measured with a cardiac probe (Nuclear Stethoscope. Bios Inc., Valhalla, New York) and sup(113m)In in 28 normal subjects and 86 patients with coronary artery disease (CAD). In 20 normal subjects sup(99m)TC-RBCs were compared with sup(113m)In, which binds to transferrin after IV injection. With sup(99m)Tc-RBCs average LVEF was 57+-7% (1 SD); with sup(113m)In, average LEVF was 55+-8% (N.S.). Sequential measurements at different times over 60 min revealed good reproducibility. Comparison of LVEF's obtained using sup(99m)Tc-RBCs with a gamma camera and cardiac probe revealed a good correlation. The correlation coefficients were 0.92 in 25 patients with CAD and 0.95 in 10 patients with LV wall motion abnormalities. The LVEF obtained using a cardiac probe and sup(113m)In increased in 28 normals from 57+-9% to 64+-13% (P<0.001) during handgrip exercise, while the LVEF decreased from 45+-9% to 41+-10% (P<0.01) in patients with acute myocardial infarction 4-7 weeks after episode, from 48+-11 to 40+-12% (P<0.001) in patients with old myocardial infarction, and from 52+-9 to 42+-9% (P<0.001) in patients with angina pectoris. The cardiac probe and sup(113m)In provide a useful alternate means of determining left ventricular dysfunction in facilities where sup(99m)Tc and a gamma camera computer system are not readily available.

  19. Measurement of left ventricular ejection fraction with ionic sup(113m)In and a cardiac probe

    International Nuclear Information System (INIS)

    Liu, X.; Harrison, K.S.; Wagner, H.N. Jr.

    1982-01-01

    Left ventricular ejection fraction (LVEF) was measured with a cardiac probe (Nuclear Stethoscope. Bios Inc., Valhalla, New York) and sup(113m)In in 28 normal subjects and 86 patients with coronary artery disease (CAD). In 20 normal subjects sup(99m)TC-RBCs were compared with sup(113m)In, which binds to transferrin after IV injection. With sup(99m)Tc-RBCs average LVEF was 57+-7% (1 SD); with sup(113m)In, average LEVF was 55+-8% (N.S.). Sequential measurements at different times over 60 min revealed good reproducibility. Comparison of LVEF's obtained using sup(99m)Tc-RBCs with a gamma camera and cardiac probe revealed a good correlation. The correlation coefficients were 0.92 in 25 patients with CAD and 0.95 in 10 patients with LV wall motion abnormalities. The LVEF obtained using a cardiac probe and sup(113m)In increased in 28 normals from 57+-9% to 64+-13% (P<0.001) during handgrip exercise, while the LVEF decreased from 45+-9% to 41+-10% (P<0.01) in patients with acute myocardial infarction 4-7 weeks after episode, from 48+-11 to 40+-12% (P<0.001) in patients with old myocardial infarction, and from 52+-9 to 42+-9% (P<0.001) in patients with angina pectoris. The cardiac probe and sup(113m)In provide a useful alternate means of determining left ventricular dysfunction in facilities where sup(99m)Tc and a gamma camera computer system are not readily available. (orig.)

  20. Relationship between plasma xanthine oxidoreductase activity and left ventricular ejection fraction and hypertrophy among cardiac patients.

    Directory of Open Access Journals (Sweden)

    Yuki Fujimura

    Full Text Available Xanthine oxidoreductase (XOR, which catalyzes purine catabolism, has two interconvertible forms, xanthine dehydrogenase and xanthine oxidase, the latter of which produces superoxide during uric acid (UA synthesis. An association between plasma XOR activity and cardiovascular and renal outcomes has been previously suggested. We investigated the potential association between cardiac parameters and plasma XOR activity among cardiology patients.Plasma XOR activity was measured by [13C2,15N2]xanthine coupled with liquid chromatography/triplequadrupole mass spectrometry. Among 270 patients who were not taking UA-lowering drugs, XOR activity was associated with body mass index (BMI, alanine aminotransferase (ALT, HbA1c and renal function. Although XOR activity was not associated with serum UA overall, patients with chronic kidney disease (CKD, those with higher XOR activity had higher serum UA among patients without CKD. Compared with patients with the lowest XOR activity quartile, those with higher three XOR activity quartiles more frequently had left ventricular hypertrophy. In addition, plasma XOR activity showed a U-shaped association with low left ventricular ejection fraction (LVEF and increased plasma B-type natriuretic peptide (BNP levels, and these associations were independent of age, gender, BMI, ALT, HbA1C, serum UA, and CKD stages.Among cardiac patients, left ventricular hypertrophy, low LVEF, and increased BNP were significantly associated with plasma XOR activity independent of various confounding factors. Whether pharmaceutical modification of plasma XOR activity might inhibit cardiac remodeling and improve cardiovascular outcome should be investigated in future studies.

  1. Urinary Proteomics Pilot Study for Biomarker Discovery and Diagnosis in Heart Failure with Reduced Ejection Fraction.

    Directory of Open Access Journals (Sweden)

    Kasper Rossing

    Full Text Available Biomarker discovery and new insights into the pathophysiology of heart failure with reduced ejection fraction (HFrEF may emerge from recent advances in high-throughput urinary proteomics. This could lead to improved diagnosis, risk stratification and management of HFrEF.Urine samples were analyzed by on-line capillary electrophoresis coupled to electrospray ionization micro time-of-flight mass spectrometry (CE-MS to generate individual urinary proteome profiles. In an initial biomarker discovery cohort, analysis of urinary proteome profiles from 33 HFrEF patients and 29 age- and sex-matched individuals without HFrEF resulted in identification of 103 peptides that were significantly differentially excreted in HFrEF. These 103 peptides were used to establish the support vector machine-based HFrEF classifier HFrEF103. In a subsequent validation cohort, HFrEF103 very accurately (area under the curve, AUC = 0.972 discriminated between HFrEF patients (N = 94, sensitivity = 93.6% and control individuals with and without impaired renal function and hypertension (N = 552, specificity = 92.9%. Interestingly, HFrEF103 showed low sensitivity (12.6% in individuals with diastolic left ventricular dysfunction (N = 176. The HFrEF-related peptide biomarkers mainly included fragments of fibrillar type I and III collagen but also, e.g., of fibrinogen beta and alpha-1-antitrypsin.CE-MS based urine proteome analysis served as a sensitive tool to determine a vast array of HFrEF-related urinary peptide biomarkers which might help improving our understanding and diagnosis of heart failure.

  2. Prognostic Estimation of Advanced Heart Failure With Low Left Ventricular Ejection Fraction and Wide QRS Interval.

    Science.gov (United States)

    Oh, Changmyung; Chang, Hyuk-Jae; Sung, Ji Min; Kim, Ji Ye; Yang, Wooin; Shim, Jiyoung; Kang, Seok-Min; Ha, Jongwon; Rim, Se-Joong; Chung, Namsik

    2012-10-01

    Cardiac resynchronization therapy (CRT) has been known to improve the outcome of advanced heart failure (HF) but is still underutilized in clinical practice. We investigated the prognosis of patients with advanced HF who were suitable for CRT but were treated with conventional strategies. We also developed a risk model to predict mortality to improve the facilitation of CRT. Patients with symptomatic HF with left ventricular ejection fraction ≤35% and QRS interval >120 ms were consecutively enrolled at cardiovascular hospital. After excluding those patients who had received device therapy, 239 patients (160 males, mean 67±11 years) were eventually recruited. During a follow-up of 308±236 days, 56 (23%) patients died. Prior stroke, heart rate >90 bpm, serum Na ≤135 mEq/L, and serum creatinine ≥1.5 mg/dL were identified as independent factors using Cox proportional hazards regression. Based on the risk model, points were assigned to each of the risk factors proportional to the regression coefficient, and patients were stratified into three risk groups: low- (0), intermediate-(1-5), and high-risk (>5 points). The 2-year mortality rates of each risk group were 5, 31, and 64 percent, respectively. The C statistic of the risk model was 0.78, and the model was validated in a cohort from a different institution where the C statistic was 0.80. The mortality of patients with advanced HF who were managed conventionally was effectively stratified using a risk model. It may be useful for clinicians to be more proactive about adopting CRT to improve patient prognosis.

  3. Therapeutic Approach to Patients with Heart Failure with Reduced Ejection Fraction and End-stage Renal Disease.

    Science.gov (United States)

    Inampudi, Chakradhari; Alvarez, Paulino; Asleh, Rabea; Briasoulis, Alexandros

    2018-03-14

    Several risk factors including Ischemic heart disease, uncontrolled hypertension, high output Heart Failure (HF) from shunting through vascular hemodialysis access, and anemia, contribute to development of HF in patients with End-Stage Renal Disease (ESRD). Guidelinedirected medical and device therapy for Heart Failure with Reduced Ejection Fraction (HFrEF) has not been extensively studied and may have limited safety and efficacy in patients with ESRD. Maintenance of interdialytic and intradialytic euvolemia is a key component of HF management in these patients but often difficult to achieve. Beta-blockers, especially carvedilol which is poorly dialyzed is associated with cardiovascular benefit in this population. Despite paucity of data, Angiotensin-converting Enzyme Inhibitors (ACEI) or Angiotensin II Receptor Blockers (ARBs) when appropriately adjusted by dose and with close monitoring of serum potassium can also be administered to these patients who tolerate beta-blockers. Mineralocorticoid receptors in patients with HFrEF and ESRD have been shown to reduce mortality in a large randomized controlled trial without any significantly increased risk of hyperkalemia. Implantable Cardiac-defibrillators (ICDs) should be considered for primary prevention of sudden cardiac death in patients with HFrEF and ESRD who meet the implant indications. Furthermore in anemic iron-deficient patients, intravenous iron infusion may improve functional status. Finally, mechanical circulatory support with leftventricular assist devices may be related to increased mortality risk and the presence of ESRD poses a relative contraindication to further evaluation of these devices. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. Higher-speed coronal mass ejections and their geoeffectiveness

    Science.gov (United States)

    Singh, A. K.; Bhargawa, Asheesh; Tonk, Apeksha

    2018-06-01

    We have attempted to examine the ability of coronal mass ejections to cause geoeffectiveness. To that end, we have investigated total 571 cases of higher-speed (> 1000 km/s) coronal mass ejection events observed during the years 1996-2012. On the basis of angular width (W) of observance, events of coronal mass ejection were further classified as front-side or halo coronal mass ejections (W = 360°); back-side halo coronal mass ejections (W = 360°); partial halo (120°mass ejections were much faster and more geoeffective in comparison of partial halo and non-halo coronal mass ejections. We also inferred that the front-sided halo coronal mass ejections were 67.1% geoeffective while geoeffectiveness of partial halo coronal mass ejections and non-halo coronal mass ejections were found to be 44.2% and 56.6% respectively. During the same period of observation, 43% of back-sided CMEs showed geoeffectiveness. We have also investigated some events of coronal mass ejections having speed > 2500 km/s as a case study. We have concluded that mere speed of coronal mass ejection and their association with solar flares or solar activity were not mere criterion for producing geoeffectiveness but angular width of coronal mass ejections and their originating position also played a key role.

  5. Real-time three-dimensional echocardiographic left ventricular ejection fraction and volumes assessment: comparison with cardiac computed tomography; Comparacao entre a afericao da fracao de ejecao e dos volumes do ventriculo esquerdo, medidos com ecocardiografia tridimensional em tempo real e com tomografia computadorizada ultra-rapida

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Marcelo L.C.; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Cury, Alexandre; Passos, Rodrigo B.D.; Nobrega, Marcel V. da; Funari, Marcelo B.G.; Pfefermam, Abhaham; Makdisse, Marcia; Fischer, Claudio H.; Morhy, Samira S., E-mail: luiz766@terra.com.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)

    2008-10-15

    Background and objective: Few studies addressed the comparison between real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) concerning left ventricular ejection fraction and volumes assessment. We sought to compare both techniques regarding left ventricle (LV) ejection fraction function and volumes analysis. Methods: we studied by RT3DE (Philips IE 33, And, MA, USA) and by CCT (Toshiba, 64-slice, Otawara, Japan) 41 consecutive patients (29 males, 58 ± 11 yrs). We analysed by both techniques LVEF, LVEDV, LVESV. RT3DE and CCT data were compared by coefficients of determination (r: Pearson), Bland and Altman test and linear regression, 95% CI. Results: RT3DE data: LVEF ranged from 56.7 to 78.9 % (65.3 + 5.7 ); LVEDV ranged from 49.6 to 178.2 (88 + 27.5) mL; LVESV from 11.4 to 78 ( 33.9 + 13.7) mL. CCT data: LVEF ranged from 53 to 86 % (67.3 + 7.9 ); LVEDV ranged from 51 to 186 (106.4 + 30.7) mL; LVESV from 7 to 72 ( 35.1 + 13.8) mL. Correlations relative to RT3DE and CCT were: LVEF (r: 0. 7877, p<0.0001, 95 % CI 0.6327 to 0.8853 ); LVEDV (r:0.7671, p<0.0001, 95 % CI 0.5974 to 0.8745); LVESV (r: 0.8121, p<0.0001, 95 % CI 0.6659 to 0.8957). Conclusions: it was observed adequate correlation between real-time 3D echocardiography and cardiac computed tomography concerning ejection fraction and volumes assessment. (author)

  6. The effect of varying the acquisition angle on processing and ejection fractions in gated blood pool studies

    International Nuclear Information System (INIS)

    Hughes, K.; Schults, C.G.; Trinh, T.

    2002-01-01

    Full text: Suboptimal ventricular definition has been blamed for difficulties in processing and variations in Ejection Fraction (EF). Clinical patients had Gated Blood Pool Studies (GBPS) performed by one of two operators, ensuring good left ventricular separation and definition. With patient consent, another study was acquired with the camera angle altered in the caudal or septal plane. Using GE Entegra GBPS Software, which allows some operator involvement in modifying the automated systolic and diastolic regions, the studies were analysed by eight 'blinded' technologists. Analyses of optimal and suboptimal acquisitions were compared. The mean, standard deviation (SD) and coefficient of variation (CV%) were determined for each patient's set of EFs. There was no significant difference in the means of the optimal and suboptimal groups (61.2% and 61.7%). One third of the suboptimal studies acquired gave a mean EF that differed by more than 5% from the Optimal' mean. The average CV of all analyses was 4.5%. The optima] group CV 4.7% (septal 4.6%/caudal 4.8%) and the suboptimal group CV 4.3% (septal 4.5%/caudal 4.2%). The analysis demonstrates that precision of processing GBPS is not affected when the study is acquired at a suboptimal angle. Although most EF results are reliable when acquired at a suboptimal angle, approximately one third will produce an EF that varies from the optimal result by more than 5%. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Left ventricular function in chronic aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Manno, B.; Amenta, A.; Kane, S.A.

    1983-01-01

    Left ventricular performance was determined in 42 patients with moderate or severe aortic regurgitation during upright exercise by measuring left ventricular ejection fraction and volume with radionuclide ventriculography. Classification of the patients according to exercise tolerance showed that patients with normal exercise tolerance (greater than or equal to 7.0 minutes) had a significantly higher ejection fraction at rest (probability [p] . 0.02) and during exercise (p . 0.0002), higher cardiac index at exercise (p . 0.0008) and lower exercise end-systolic volume (p . 0.01) than did patients with limited exercise tolerance. Similar significant differences were noted in younger patients compared with older patients in ejection fraction at rest and exercise (both p . 0.001) and cardiac index at rest (p . 0.03) and exercise (p . 0.0005). The end-diastolic volume decreased during exercise in 60% of the patients. The patients with a decrease in volume were significantly younger and had better exercise tolerance and a larger end-diastolic volume at rest than did patients who showed an increase in volume. The mean corrected left ventricular end-diastolic radius/wall thickness ratio was significantly greater in patients with abnormal than in those with normal exercise reserve (mean +/- standard deviation 476 +/- 146 versus 377 +/- 92 mm Hg, p less than 0.05). Thus, in patients with chronic aortic regurgitation: 1) left ventricular systolic function during exercise was related to age, exercise tolerance and corrected left ventricular end-diastolic radius/wall thickness ratio, and 2) the end-diastolic volume decreased during exercise, especially in younger patients and patients with normal exercise tolerance or a large volume at rest

  8. [Surgical revascularisation of the heart in patients with chronic ischaemic cardiomyopathy and leftventricular ejection fraction of less than 30%].

    Science.gov (United States)

    Velinović, Milos; Kocica, Mladen; Vranes, Mile; Mikić, Aleksandar; Vukomanović, Vlada; Davidović, Lazar; Obrenović-Krićanski, Biljana; Cvetkovic, Slobodan; Soski, Ljiljana; Ristić, Arsen D

    2005-01-01

    Patients suffering from chronic ischaemic cardiomyopathy and left ventricular ejection fraction (LVEF) lower than 30% represent a difficult and controversial population for surgical treatment. The aim of this study was to evaluate the effects of surgical treatment on the early and long-term outcome of these patients. The patient population comprised 50 patients with LVEF < 30% (78% male, mean age: 58.3 years, range: 42-75 years) who underwent surgical myocardial revascularisation during the period 1995-2000. Patients with left ventricular aneurysms or mitral valve insufficiency were excluded from the study. The following echocardiography parameters were evaluated as possible prognostic indicators: LVEF, fraction of shortening (FS), left ventricular systolic and diastolic diameters (LVEDD, LVESD) and volumes (LVEDV, LVESV), as well as their indexed values (LVESVI). Fifteen patients (30%) died during the follow-up, 2/50 intraoperatively (4%). The presence of diabetes mellitus, previous myocardial infarction, main left coronary artery disease, and three-vessel disease, correlated significantly with the surgical outcomes. The patient's age, family history, smoking habits, hypertension, hyperlipidaemia, history of stroke, peripheral vascular disease, and renal failure, did not correlate with the mortality rate. A comparison of preoperative echocardiography parameters between survivors and non-survivors revealed significantly divergent LVEF, LVEDD, LVESD, LVEDV, LVESV, and LVESVI values. Preoperative LVESVI offered the highest predictive value (R = 0.595). Diabetes mellitus, history of myocardial infarction, stenosis of the main branch, and three-vessel disease, significantly affected the perioperative and long-term outcome of surgical revascularisation in patients with ischaemic cardiomyopathy and LVEF < 30%. In survivors, LVEF, FS, and systolic and diastolic echocardiography parameters, as well as their indexed values, significantly improved after surgical

  9. Prognostic implications of post-stress ejection fraction decrease detected by gated SPECT in the absence of stress-induced perfusion abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Dona, Manjola; Massi, Lucia; Settimo, Leonardo; Bartolini, Matteo; Gianni, Gianluca; Pupi, Alberto; Sciagra, Roberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy)

    2011-03-15

    The prognostic meaning of a post-stress ejection fraction (EF) decrease detected by perfusion gated SPECT is still unclear. We therefore followed up patients with post-stress EF decrease in the absence of stress-induced perfusion abnormalities. We prospectively enrolled 57 consecutive patients with post-stress EF drop {>=} 5 EF units and summed difference score (SDS) {<=} 1. They were followed up for more than 1 year and their outcome was compared with a group of sex- and age-matched controls with the same SDS but without EF decrease. During follow-up there were 13 events (1 cardiac death, 1 non-fatal myocardial infarction, 1 congestive heart failure and 10 late revascularizations). In the control group we registered six events. There was a significant difference (p < 0.0001) between the event-free survival curves of the two groups. The event rate of patients with post-stress EF decrease {>=} 5 EF units is relatively high and is significantly worse than that of a control group of patients with similarly normal SDS but without EF changes. Therefore, a post-stress EF decrease without stress-induced perfusion abnormalities should be cautiously interpreted. (orig.)

  10. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  11. Difference in resting-state fractional amplitude of low-frequency fluctuation between bipolar depression and unipolar depression patients.

    Science.gov (United States)

    Yu, H-L; Liu, W-B; Wang, T; Huang, P-Y; Jie, L-Y; Sun, J-Z; Wang, C; Qian, W; Xuan, M; Gu, Q-Q; Liu, H; Zhang, F-L; Zhang, M-M

    2017-04-01

    To investigate the difference in fractional amplitude of low-frequency fluctuation (fALFF) of localized brain activities in the resting-state between bipolar depression and unipolar depression patients and to find biological markers that differentiate the two groups of patients. Thirteen patients with bipolar depression, 15 patients with unipolar depression, and 16 healthy control subjects that were matched in age and years of education were subjected to 3.0 T resting-state functional magnetic resonance scans. The values of whole brain fALFF were calculated and statistical analysis was performed. The fALFF-values of the right inferior temporal gyrus, left cerebellar posterior lobe, right middle temporal gyrus, left inferior frontal gyrus/insula, right inferior frontal gyrus/insula, left lingual gyrus and right middle temporal gyrus of the three groups showed significant differences (p superior temporal gyrus, left insula, left inferior frontal gyrus, right inferior frontal gyrus, right supramarginal gyrus and right medial frontal gyrus but significantly decreased in the right medial occipital gyrus, left frontal lobe, right superior parietal lobule; the fALFF-values of the bipolar depression (BD) patient group significantly decreased in the left cerebellum posterior lobe, right lingual gyrus, left lingual gyrus, right middle temporal gyrus, left middle temporal gyrus, and left superior frontal gyrus and significantly increased in the right inferior frontal gyrus and left insula compared to those of the HC group; compared with those of the UD group, the fALFF-values of the BD group significantly decreased in the left middle occipital gyrus, right middle temporal gyrus, left middle frontal gyrus, and left medial frontal gyrus. The brain activities of BD and UD patients in the resting-state exhibit abnormalities, which differ between the two groups of patients.

  12. Both semiquantitative degree of rest Tl-201 uptake and reversibility at 24 hour-delay were needed to predict wall motion improvement after bypass surgery

    International Nuclear Information System (INIS)

    Lee, D. S.; Yoon, S. N.; Kim, K. B.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Controversy still exists about how to use the uptake at rest and 24 hour delay in rest redistribution Tl-201 SPECT to predict improvement of wall motion abnormality after bypass surgery. To find the best way to combine diagnostic efficacy of Tl-201 SPECT to predict myocardial viability, we studied the predictive values (positive: PPV, negative: NPV) of rest and 24 hour-delay Tl-201 SPECT in 21 patients. Wall motion was assessed comparing preoperative post-stress gated Tc-99m-MIBI SPECT with that of 3 months after surgery. Four point scoring system was used for 17 myocardial segments to asses uptakes ( 0 to 3 for normal to defect) at rest and 24 hour-delay and wall motion ( 0 to 3 for normal to dyskinesia). Ejection fraction improved after surgery (5011% vs 4313%). Intra-observer and inter-observer reproducibility of EF was 7 and 9% respectively when we used 3D Perfusion-Motion Map. Sixty seven segments showed wall motion abnormality before surgery. Predictive values of rest Tl-201 uptake decrease were as follows: 0: 15/15(100%), 1: 30/34(88%), 2: 6/11 (55%), 3: 3/7(43%). So PPV of mild decrease was 88%, and NPV of severe decrease was 50%. Delayed reversibility was evaluated in 37 segments (15 patients). Twenty seven segment had persistence or aggravation, but the other 10 segments improved at 24 hour delay. PPV of reversible 10 segments was 80%, and NPV of reversibility was only 46%. PPV of combination of rest Tl-201 uptake of mild degree and 24 hour reversibility was 86% (38/44) and NPV of neither one was 88%. We concluded that both semi-quantitative degree of Tl-201 uptake at rest and reversibility at 24 hour delay was the best to warrant or abandon postoperative improvement of abnormal wall motion found at preoperative post-stress gated myocardial SPECT

  13. Exercise radionuclide ventriculographic responses in hypertensive patients with chest pain

    International Nuclear Information System (INIS)

    Wasserman, A.G.; Katz, R.J.; Varghese, P.J.; Leiboff, R.H.; Bren, G.G.; Schlesselman, S.; Varma, V.M.; Reba, R.C.; Ross, A.M.

    1984-01-01

    The effectiveness of exercise-treadmill testing in diagnosing coronary-artery disease in hypertensive patients is limited by a high rate of false positivity. Exercise radionuclide ventriculography, however, relies on different criteria (ejection fraction and wall motion), and we have evaluated this procedure in 37 hypertensive and 109 normotensive patients with chest pain, using coronary arteriography as an indicator of coronary disease. In the hypertensive cohort there was no difference in the ejection fraction at rest between the 17 patients with coronary disease and the 20 without it. Neither group had a significant mean (+/- S.E.M.) change in ejection fraction from rest to exercise (-1.9 +/- 2 and 1.4 +/- 1%, respectively). A wall-motion abnormality developed during exercise in 5 of the 17 hypertensive patients with coronary disease (29%) and in 4 of the 20 without it (20%) (P = not significant). In the normotensive cohort, however, the peak-exercise ejection fractions were significantly different. The 71 patients with coronary disease had a mean decrease of 3.6 +/- 1%, in contrast to the patients without coronary disease, who had an increase of +/- 1% (P < 0.001). An exercise-induced wall-motion abnormality was seen in 35 of the 71 patients with coronary disease (48%), as compared with 3 of the 38 without it (8%) (P < 0.001). We conclude that exercise radionuclide ventriculography is inadequate as a screening test for coronary atherosclerosis in hypertensive patients with chest pain. 28 references, 2 figures, 3 tables

  14. Advances in the pharmacotherapy of chronic heart failure with preserved ejection fraction: an ideal opportunity for precision medicine.

    Science.gov (United States)

    Polsinelli, Vincenzo B; Shah, Sanjiv J

    2017-03-01

    Heart failure with preserved ejection fraction (HFpEF), which comprises approximately 50% of all heart failure patients, is a challenging and complex clinical syndrome that is often thought to lack effective treatments. Areas covered: Despite the common mantra that HFpEF has no effective treatments, closer inspection of HFpEF clinical trials reveals that several of the drugs tested are associated with benefits in exercise capacity and quality of life, and reduction in heart failure hospitalization. Here we review major randomized controlled trials in HFpEF, focusing on renin-angiotensin-aldosterone system antagonists, organic nitrates, digoxin, beta-blockers, and phosphodiesterase-5 inhibitors. In addition, we review several classes of drugs currently in development for HFpEF such as neprilysin inhibitors, inorganic nitrates (nitrites), and soluble guanylate cyclase stimulators. Expert opinion: HFpEF should not be viewed as lacking effective treatments. While there have been no breakthrough clinical trials showing a reduction in mortality, several existing medications are likely to benefit specific subgroups of HFpEF patients. HFpEF is now well known to be a heterogeneous syndrome; thus, the clinical management of HFpEF patients and future HFpEF clinical trials will both likely require a nuanced, phenotype-specific approach instead of a one-size-fits-all tactic. Drug development for HFpEF therefore represents an exciting opportunity for personalized medicine.

  15. New approach for simplified and automated measurement of left ventricular ejection fraction by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu; Adachi, Haruhiko; Sugihara, Hiroki; Katsume, Hiroshi; Ijichi, Hamao; Okamoto, Kunio; Hosoba, Minoru

    1984-12-01

    Background (BKG) correction is important but debatable in the measurement of Left ventricular ejection fraction (LVEF) with ECG gated blood pool scintigraphy. We devised a new simplified BKG processing (fixed BKG method) without BKG region-of-interest (ROI) assignment, and the accuracy and reproducibility were assessed in 25 patients with various heart diseases and 5 normal subjects by comparison with LVEF obtained by contrast levolgraphy (LVG-EF). Four additional protocols for LVEF measurement with BKG-ROI assignment were also assessed for reference. LVEF calculated using the fixed BKG ratio of 0.64 (BKG count rates were 64%) of end-diastolic count rates of LV) with ''Fixed'' LV-ROI was best correlated with LVG-EF (r = 0.936, p < 0.001) and most approximated (Fixed BKG ratio method EF: 61.1 +- 20.1, LVG-EF: 61.2 +- 20.4% (mean +- SD)) among other protocols. The wide availability of the fixed value of 0.64 was tested in various diseases, body size and end-diastolic volume by LVG, and the results were to be little influenced by them. Furthermore, fixed BKG method produced lower inter-and intra- observer variability than other protocols requiring BKG-ROI assignment, probably due to its simplified processing. In conclusion, fixed BKG ratio method simplifies the measurement of LVEF, and is feasible for automated processing and single probe system.

  16. Sacubitril/valsartan for heart failure with reduced left ventricular ejection fraction : A retrospective cohort study.

    Science.gov (United States)

    De Vecchis, R; Ariano, C; Di Biase, G; Noutsias, M

    2018-01-19

    The combination drug sacubitril/valsartan was reported to be superior to enalapril in reducing all-cause death, cardiovascular mortality, and heart failure (HF) hospitalizations in patients with cardiac insufficiency and reduced left ventricular ejection fraction (HFREF) with NYHA class II-IV. Our retrospective cohort study aimed to assess the effects of sacubitril/valsartan in addition to a beta-blocker and mineral receptor antagonist (MRA) in a group of HFREF patients with NYHA class II-III HF vs. conventional therapy (ACE inhibitor or angiotensin II receptor blocker added to a beta-blocker plus an MRA) administered to a control group of HFREF patients with comparable clinical features. In both groups, treatment was supplemented by a loop diuretic, usually furosemide, at variable doses. The primary outcomes were all-cause death and HF hospitalizations. Safety outcomes were symptomatic hypotension, angioedema, hyperkalemia, and worsening renal function. Mortality at 6 months was 6.8% in patients taking sacubitril/valsartan vs. 34% in those on conventional therapy (odds ratio [OR] = 0.14; 95% CI: 0.04-0.49). Moreover, there was a 4.5% rate of HF hospitalizations in the sacubitril/valsartan group vs. 59% in the control group (OR = 0.03; 95% CI: 0.01-0.14). Safety outcomes were comparable in the two groups, although hypotension (systolic blood pressure sacubitril/valsartan group vs. 5.7% in the control group (OR = 3.14; 95% CI: 0.94-10.55). Sacubitril/valsartan offered strong protection against all-cause death and HF hospitalizations at 6 months without any significant side effects. To validate this efficacious molecule, further postmarketing observational studies, focusing mainly on hypotension and angioedema are warranted.

  17. Cost-effectiveness of sacubitril/valsartan in the treatment of heart failure with reduced ejection fraction.

    Science.gov (United States)

    McMurray, John J V; Trueman, David; Hancock, Elizabeth; Cowie, Martin R; Briggs, Andrew; Taylor, Matthew; Mumby-Croft, Juliet; Woodcock, Fionn; Lacey, Michael; Haroun, Rola; Deschaseaux, Celine

    2018-06-01

    Chronic heart failure with reduced ejection fraction (HF-REF) represents a major public health issue and is associated with considerable morbidity and mortality. We evaluated the cost-effectiveness of sacubitril/valsartan (formerly LCZ696) compared with an ACE inhibitor (ACEI) (enalapril) in the treatment of HF-REF from the perspective of healthcare providers in the UK, Denmark and Colombia. A cost-utility analysis was performed based on data from a multinational, Phase III randomised controlled trial. A decision-analytic model was developed based on a series of regression models, which extrapolated health-related quality of life, hospitalisation rates and survival over a lifetime horizon. The primary outcome was the incremental cost-effectiveness ratio (ICER). In the UK, the cost per quality-adjusted life-year (QALY) gained for sacubitril/valsartan (using cardiovascular mortality) was £17 100 (€20 400) versus enalapril. In Denmark, the ICER for sacubitril/valsartan was Kr 174 000 (€22 600). In Colombia, the ICER was COP$39.5 million (€11 200) per QALY gained. Deterministic sensitivity analysis showed that results were most sensitive to the extrapolation of mortality, duration of treatment effect and time horizon, but were robust to other structural changes, with most scenarios associated with ICERs below the willingness-to-pay threshold for all three country settings. Probabilistic sensitivity analysis suggested the probability that sacubitril/valsartan was cost-effective at conventional willingness-to-pay thresholds was 68%-94% in the UK, 84% in Denmark and 95% in Colombia. Our analysis suggests that, in all three countries, sacubitril/valsartan is likely to be cost-effective compared with an ACEI (the current standard of care) in patients with HF-REF. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Csernay, L.; Mester, J.; Edes, I.; Pavics, L.; Gruber, N.; Szasz, K.; Csanady, M.

    1985-08-04

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed

  19. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    International Nuclear Information System (INIS)

    Csernay, Laszlo; Mester, Janos; Edes, Istvan; Pavics, Laszlo; Gruber, Noemi; Szasz, Karoly; Csanady, Miklos

    1985-01-01

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed. (author)

  20. Aircrew ejection experience: questionnaire responses from 20 survivors.

    Science.gov (United States)

    Taneja, Narinder; Pinto, Leslie J; Dogra, Manmohan

    2005-07-01

    Published studies on ejection have focused predominantly on the injuries sustained by aircrew and discussed their preventive measures from an aeromedical perspective. However, studies have not discussed aircrew experiences related to ejection or how they would like to advise other aircrew to successfully handle ejection as an event. Such information can assist in designing realistic indoctrination and training programs. This study was conducted to fill gaps in our understanding of aircrew perspectives of successful ejections. Aircrew reporting to the Institute of Aerospace Medicine (IAM), Indian Air Force, for post-ejection evaluation during the period of May 2003 to January 2005 completed a questionnaire that was designed for the study. A total of 20 aircrew completed this questionnaire. The mean age of the aircrew was 30.25 +/- 4.45 yr. Most of them had logged more than 500 flying hours. Some aircrew described their initial moments of ejection as "blacked out," "dazed, yet conscious," or as "a shock that gradually decreased." Practicing ejection drills on the ground, being prepared at all times, making a timely decision to eject, and assuming correct posture were identified as the most important factors for success. Descriptions of ejection as an event suggest intense emotional arousal could occur following ejection. This study provides first hand inputs into the psychological processes accompanying ejections. Such information could be very useful in understanding the critical factors that influence successful ejection.

  1. Scintigraphic ventriculography and stress testing

    International Nuclear Information System (INIS)

    Goris, M.L.; Hung, J.; Debusk, R.F.

    1982-01-01

    Scintigraphic stress ventriculography yields information which is complex and defies description by the difference in ejection fraction between rest and maximum exercise only. The complexity results in part from the ''derived'' nature of the ejection fraction measurement, which is physiologically secondary to stroke volume and end-diastolic volume. Furthermore, the nature of the stress test in which the pulse (stress) is not independent from the response forces an analysis which considers ''when'' as much as ''what'' happens. Automation in data processing, however, has made oversimplification unnecessary and allows a more exhaustive but correct analysis

  2. Effect of early treatment with ivabradine combined with beta-blockers versus beta-blockers alone in patients hospitalised with heart failure and reduced left ventricular ejection fraction (ETHIC-AHF): A randomised study.

    Science.gov (United States)

    Hidalgo, Francisco J; Anguita, Manuel; Castillo, Juan C; Rodríguez, Sara; Pardo, Laura; Durán, Enrique; Sánchez, José J; Ferreiro, Carlos; Pan, Manuel; Mesa, Dolores; Delgado, Mónica; Ruiz, Martín

    2016-08-15

    To analyse the effect of the early coadministration of ivabradine and beta-blockers (intervention group) versus beta-blockers alone (control group) in patients hospitalised with heart failure and reduced left ventricular ejection fraction (HFrEF). A comparative, randomised study was performed to compare the treatment strategies of beta-blockers alone versus ivabradine and beta-blockers starting 24hours after hospital admission, for acute HF in patients with an left ventricular ejection fraction (EF)70bpm. A total of 71 patients were examined, 33 in the intervention group and 38 in the control group. No differences were observed with respect to their baseline characteristics or standard treatment at discharge. HR at 28days (64.3±7.5 vs. 70.3±9.3bpm, p=0.01) and at 4months (60.6±7.5 vs. 67.8±8bpm, p=0.004) after discharge were significantly lower in the intervention group. Significant differences were found with respect to the EF and brain natriuretic peptide levels at 4months. No differences in clinical events (rehospitalisation/death) were reported at 4months. No severe side effects attributable to the early administration of ivabradine were observed. The early coadministration of ivabradine and beta-blockers during hospital admission for acute HFrEF is feasible and safe, and it produces a significant decrease in HR at 28days and at 4months after hospital discharge. It also seemed to improve systolic function and functional and clinical parameters of HF patients at short-term. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Severe aortic stenosis patients with preserved ejection fraction according to flow and gradient classification: Prevalence and outcomes.

    Science.gov (United States)

    González Gómez, Ariana; Fernández-Golfín, Covadonga; Monteagudo, Juan Manuel; Izurieta, Carlos; Hinojar, Rocío; García, Ana; Casas, Eduardo; Jiménez-Nacher, José Julio; Moya, José Luis; Ruiz, Soledad; Zamorano, José Luis

    2017-12-01

    Clinicians often encounter patients with apparently discordant echocardiographic findings, severe aortic stenosis (SAS) defined by aortic valve area (AVA) despite a low mean gradient. A new classification according to flow state and pressure gradient has been proposed. We sought to assess the prevalence, characteristics and outcomes of patients with asymptomatic SAS with preserved left-ventricular ejection fraction (LVEF) according to flow and gradient. In total 442 patients with SAS (AVAigradient (≥ or Gradient (LF/LG): 21.3%(n=94); Normal Flow/Low Gradient (NF/LG): 32.1%(n=142); Low Flow/High Gradient (LF/HG): 6.8%(n=30); Normal Flow/High Gradient (NF/HG): 39,8%(n=176). Mean follow-up time was 20.5months (SD=10.3). Primary combined endpoint was cardiovascular mortality and hospital admission for SAS related symptom, secondary endpoint was aortic valve replacement (AVR), comparing HG group to LF/LG group. During follow-up 17 (18%) of LF/LG patients and 21 (10.2%) of HG patients met the primary endpoint. A lower free of event survival (cardiovascular mortality and hospital admission) was observed in patients with LF/LG AS (Breslow, p=0.002). Significant differences were noted between groups with a lower AVR free survival in the LF/LG group compared to HG groups (Breslow, p=0.002). Our study confirms the high prevalence and worse prognosis of LF/LG SAS. Clinicians must be aware of this entity to ensure appropriate patient management. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  4. Thallium-201 right lung/heart ratio during exercise in patients with coronary artery disease: relation to thallium-201 myocardial single-photon emission tomography, rest and exercise left ventricular function and coronary angiography

    International Nuclear Information System (INIS)

    Morel, O.; Pezard, P.; Le Jeune, J.J.; Denizot, B.; Jallet, P.; Furber, A.; Vielle, B.

    1999-01-01

    The aim of this study was to correlate lung thallium-201 uptake on exercise with 201 Tl single-photon emission tomography (SPET) myocardial perfusion imaging, rest and exercise equilibrium radionuclide angiographic and coronary angiographic findings in patients with coronary artery disease (CAD) using a simple, reproducible lung/heart (L/H) ratio that would be easy to use in clinical practice. L/H ratio was defined on the anterior planar image obtained during exercise 201 Tl SPET acquisition as the mean counts per pixel in an entire right lung field region of interest divided by the mean counts per pixel in the hottest myocardial wall region of interest. We studied 103 patients. Fifty-nine patients (group I) with 201 Tl SPET, radionuclide angiographic and coronary angiographic variables. The group I L/H ratio of 0.35±0.05 (mean ±1 SD) was significantly lower (P 0.45 (mean+2 SD in group I) was considered abnormal. In group II, L/H ratio showed a significant correlation with stress and rest 201 Tl perfusion defect size (r=0.39 and r=0.42, P<0.01, respectively), but not with extent of ischaemic myocardium. The mean L/H ratio was 0.41±0.10 in patients with one-vessel disease (n=15), 0.46±0.08 in those with two-vessel disease (n=17) and 0.47±0.12 in those with three-vessel disease (n=12), but no significant difference was found between the three subgroups. L/H ratio showed a significant inverse relation with rest and exercise left ventricular ejection fraction (r=-0.37 and r=-0.50, P<0.05 and P<0.001, respectively). Using stepwise multiple regression analysis, exercise left ventricular ejection fraction and previous history of hypertension were the sole two variables independently predictive of the L/H ratio. In conclusion, although lung thallium uptake is usually found to correlate with extent and severity of CAD, increased L/H ratio should primarily be considered as a marker of exercise-induced left ventricular systolic and perhaps diastolic dysfunction, probably

  5. Control rod ejection analysis during a depressurization accident and the development of a rod-ejection-preventing device

    International Nuclear Information System (INIS)

    Mitake, S.; Itoh, K.; Fukushima, H.; Inoue, T.

    1982-01-01

    The control rods used for the experimental VHTR are suspended in the core by means of flexible steel cables and it is conceivable that an accidental rod ejection could occur due to a depressurization accident. The computer code AFLADE was developed in order to analyze the possibility of accidental rod ejection, and several studies were performed. The parametric study results showed that the adopted design condition for the VHTR core will not cause a rod ejection accident. In parallel with these accident analyses, a rod-ejection-preventing device was developed in preparation for a hypothetical accident, and its function was verified by the component tests

  6. Usefulness of rest-redistribution on thallium myocardial scintigraphy in patients with acute myocardial infarction by SPECT; Analysis by bull's eye and unfolded map images

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yorio; Taya, Makoto; Sasaki, Akira; Nishimura, Tooru; Shimoyama, Katsuya; Mizuno, Haruyoshi; Ono, Akifumi; Okada, Michio; Ishikawa, Kyozo (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine)

    1990-01-01

    The purpose of this study was to clarify the clinical significance of rest-redistribution in myocardial scintigraphy (SPECT) in acute myocardial infarction (AMI). 30 patients with AMI within one week after the onset of attack were studied. SPECT images were obtained 10 min and 3hrs after injection of {sup 201}Tl. Bull's eye images and unfolded map images were prepared. A {sup 201}Tl uptake was studied at the infarct and non-infarct sites. Exercise SPECT and radionuclide angiography were performed in all patients one month after the onset of AMI, and the findings were compared with clinical and coronary angiographic (CAG) findings. Redistribution of Tl at rest was observed at the infarct sites in 9 of the 30 patients. Redistribution at rest was observed at the non-infarct sites in 8 patients. Redistribution at rest was observed during exercise SPECT one month after the onset of AMI in patients with redistribution at rest in the acute phase. In patients with redistribution at rest at the infarct site, left ventricular ejection fraction (EF) improved one month after the onset of AMI ({Delta}EF>5%), but it decreased slightly during exercise. Wall motion at the infarct site was not much impaired in patients who showed redistribution at rest at the infarct site. Angina pectoris and recurrence of myocardial infarction were observed more frequently on SPECT, but no characteristic findings were obtained on CAG in those with redistribution at rest. In conclusion, cardiac function and wall motion at the infarct site are better preserved in patients with redistribution of Tl at rest on SPECT in the acute stage of myocardial infarction, as compared with patients having fixed defects, but the EF decrease slightly during exercise and the frequency of post-infarction angina is greater in those patients. Resting SPECT in AMI is considered to provide useful information for predicting cardiac function and the clinical course following myocardial infarction. (author).

  7. Utility of Cardiovascular Magnetic Resonance-Derived Wave Intensity Analysis As a Marker of Ventricular Function in Children with Heart Failure and Normal Ejection Fraction.

    Science.gov (United States)

    Ntsinjana, Hopewell N; Chung, Robin; Ciliberti, Paolo; Muthurangu, Vivek; Schievano, Silvia; Marek, Jan; Parker, Kim H; Taylor, Andrew M; Biglino, Giovanni

    2017-01-01

    This study sought to explore the diagnostic insight of cardiovascular magnetic resonance (CMR)-derived wave intensity analysis to better study systolic dysfunction in young patients with chronic diastolic dysfunction and preserved ejection fraction (EF), comparing it against other echocardiographic and CMR parameters. Evaluating systolic and diastolic dysfunctions in children is challenging, and a gold standard method is currently lacking. Patients with presumed diastolic dysfunction [ n  = 18; nine aortic stenosis (AS), five hypertrophic, and four restrictive cardiomyopathies] were compared with age-matched control subjects ( n  = 18). All patients had no mitral or aortic incompetence, significant AS, or reduced systolic EF. E / A ratio, E / E ' ratio, deceleration time, and isovolumetric contraction time were assessed on echocardiography, and indexed left atrial volume (LAVi), acceleration time (AT), ejection time (ET), and wave intensity analyses were calculated from CMR. The latter was performed on CMR phase-contrast flow sequences, defining a ratio of the peaks of the early systolic forward compression wave (FCW) and the end-systolic forward expansion wave (FEW). Significant differences between patients and controls were seen in the E / E ' ratio (8.7 ± 4.0 vs. 5.1 ± 1.3, p  = 0.001) and FCW/FEW ratio (2.5 ± 1.6 vs. 7.2 ± 4.2 × 10 -5 m/s, p  wave intensity-derived ratio summarizing systolic and diastolic function could provide insight into ventricular function in children, on top of CMR and echocardiography, and it was here able to identify an element of ventricular dysfunction with preserved EF in a small group of young patients.

  8. Impact of right ventricular distensibility on congestive heart failure with preserved left ventricular ejection fraction in the elderly.

    Science.gov (United States)

    Harada, Daisuke; Aasanoi, Hidetsugu; Ushijima, Ryuichi; Noto, Takahisa; Takagawa, Junya; Ishise, Hisanari; Inoue, Hiroshi

    2018-06-01

    To elucidate involvement of age-related impairments of right ventricular (RV) distensibility in the elderly congestive heart failure (CHF), we examined the prevalence of less-distensible right ventricle in patients with preserved left ventricular ejection fraction (LVEF) over a wide range of ages. In 893 patients aged from 40 to 102 years, we simultaneously recorded electrocardiogram, phonocardiogram, and jugular venous pulse wave. Using signal-processing techniques, the prominent 'Y' descent of jugular pulse waveform was detected as a hemodynamic sign of a less-distensible right ventricle. Prevalence of less-distensible right ventricle and elevated RV systolic pressure increased along with aging from the 50s to the 90s in an exponential fashion from 3.3 and 12% up to 33 and 61%, respectively (p right ventricle (Odds ratio, 1.05 per 1 year, p = 0.003; and 1.03 per 1 mmHg, p = 0.026, respectively). The elderly CHF was associated with high prevalence of the less-distensible right ventricle and higher RV systolic pressure, both of which were independent risk factors for CHF (Odds ratio, 5.27, p = 0.001, and 1.08 per 1 mmHg, p right ventricle and a high RV systolic pressure seems to be related to developing CHF. The less-distensible right ventricle and elevated RV systolic pressure are closely associated with CHF with preserved LVEF in the elderly patients.

  9. Amplitude of low-frequency fluctuation (ALFF) and fractional ALFF in migraine patients: a resting-state functional MRI study

    International Nuclear Information System (INIS)

    Wang, J.-J.; Chen, X.; Sah, S.K.; Zeng, C.; Li, Y.-M.; Li, N.; Liu, M.-Q.; Du, S.-I.

    2016-01-01

    Aim: To evaluate the amplitude of low-frequency oscillations (LFOs) of the brain in migraine patients using amplitude of low-frequency fluctuation (ALFF) and fractional ALFF in the interictal period, in comparison to healthy controls (HCs). Materials and methods: A total of 54 subjects, including 30 migraineurs and 24 gender- and age-matched HCs completed the fMRI. All the data and ALFF, fALFF analyses were preprocessed with the Data Processing Assistant for Resting-State fMRI (DPARSF). All of the statistical analyses were performed using the REST software to explore the differences in ALFF and fALFF between migraine patients and HCs. Results: In contrast to HCs, migraine patients showed significant ALFF increase in the left medulla and pons, the bilateral cerebellum posterior lobe and right insula. The regions showing decreased ALFF in migraine patients included the bilateral cerebellum posterior lobe, left cerebellum anterior lobe, bilateral orbital cortex, right middle frontal gyrus, bilateral occipital lobe, right fusiform gyrus, and bilateral postcentral gyrus. The fALFFs in migraine patients were significantly increased in the bilateral insular and left orbital cortex, but were decreased in the left occipital lobe and bilateral cerebellum posterior lobe. Conclusion: These ALFF and fALFF alterations in the brain regions of migraineurs are in keeping with the domains associated with pain and cognition. Such brain functional alteration may contribute to further understanding of migraine-related network imbalances demonstrated in previous studies. - Highlights: • Migraine is a common, paroxysmal, highly disabling primary headache disorder. • Resting-state fMRI offers a novel approach to measure spontaneous brain activity in migraine patients • The ALFF and fALFF alterations in migraineurs' brain regions are in keeping with the domains associated with pain and cognition.

  10. Beat-to-beat evaluation of left ventricular ejection in cardiac arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.

    1982-01-01

    Conventional multi-gated cardiac blood pool studies suffer from two kinds of superimpositions: the spatial overlapping of various heart chambers and the temporal superimposition of a large number of cardiac cycles. The first problem can be partially solved by first pass techniques or by emission tomography. For the second one, which is specially critical arrhythmias, the single probe device (''nuclear stethoscope'') represents an original solution. Patients with normal cardiac rythm and patients presenting various kinds of cardiac rythm alterations were examined using a commercial ''nuclear stethoscope''. Some characteristic results achieved in these cases, were presented. For blood pool labeling, 20 mCi of 99mTc albumin was injected. The single probe detector was then positioned over the left ventricular area. The beat-to-beat left ventricular activity curve was then recorded for several minutes on paper in the same time as the E.C.G. signal. In cases with irregular cardiac rythm, the multigated techniques yield an average value of left ventricular ejection. Due to the relatively constant duration of systole, the superimposition of cycles may be valid during contration: differences mainly appear during diastole. But, as it could be demonstrated using the ''nuclear stethoscope'', individual cycles can show a large variability of ejection and average ejection fraction is only a very partial aspect of the real cardiac function

  11. Echocardiographic dimensions and function in adults with primary growth hormone resistance (Laron syndrome).

    Science.gov (United States)

    Feinberg, M S; Scheinowitz, M; Laron, Z

    2000-01-15

    Patients with primary growth hormone (GH) resistance-Laron Syndrome (LS)-have no GH signal transmission, and thus, no generation of circulating insulin-like growth factor-I (IGF-I), and should serve as a unique model to explore the controversies concerning the longterm effect of GH/IGF-I deficiency on cardiac dimension and function. We assessed 8 patients with LS (4 men, 4 women) with a mean (+/- SD) age of 38+/-7 years (range 22 to 45), and 8 aged-matched controls (4 men, 4 women) with a mean age of 38+/-9 years (range 18 to 47) by echocardiography at rest, following exercise, and during dobutamine administration. Left ventricular (LV) septum, posterior wall, and end-diastolic diameter were significantly reduced in untreated patients with LS compared with the control group (p<0.05 for all). Systolic Doppler-derived parameters, including LV stroke volume, stroke index, cardiac output, and cardiac index, were significantly lower (p<0.05 for all) than in the control subjects, whereas LV diastolic Doppler parameters, including mitral valve waves E, A, E/A ratio, and E deceleration time, were similar in both groups. LV ejection fraction at rest as well as the stress-induced increment of the LV ejection fraction were similar in both groups. Our results show that untreated patients with long-term IGF-I deficiency have reduced cardiac dimensions and output but normal LV ejection fraction at rest and LV contractile reserve following stress.

  12. Detecting abnormalities in left ventricular function during exercise by respiratory measurement

    International Nuclear Information System (INIS)

    Koike, A.; Itoh, H.; Taniguchi, K.; Hiroe, M.

    1989-01-01

    The degree of exercise-induced cardiac dysfunction and its relation to the anaerobic threshold were evaluated in 23 patients with chronic heart disease. A symptom-limited exercise test was performed with a cycle ergometer with work rate increased by 1 W every 6 seconds. Left ventricular function, as reflected by ejection fraction, was continuously monitored with a computerized cadmium telluride detector after the intravenous injection of technetium-labeled red blood cells. The anaerobic threshold (mean, 727 ± 166 ml/min) was determined by the noninvasive measurement of respiratory gas exchange. As work rate rose, the left ventricular ejection fraction increased but reached a peak value at the anaerobic threshold and then fell below resting levels. Ejection fraction at rest, anaerobic threshold, and peak exercise were 41.4 ± 11.3%, 46.5 ± 12.0%, and 37.2 ± 11.0%, respectively. Stroke volume also increased from rest (54.6 ± 17.0 ml/beat) to the point of the anaerobic threshold (65.0 ± 21.2 ml/beat) and then decreased at peak exercise (52.4 ± 18.7 ml/beat). The slope of the plot of cardiac output versus work rate decreased above the anaerobic threshold. The anaerobic threshold occurred at the work rate above which left ventricular function decreased during exercise. Accurate determination of the anaerobic threshold provides an objective, noninvasive measure of the oxygen uptake above which exercise-induced deterioration in left ventricular function occurs in patients with chronic heart disease

  13. Comparison of Causes of Death After Heart Transplantation in Patients With Left Ventricular Ejection Fractions ≤35% Versus >35.

    Science.gov (United States)

    Birati, Edo Y; Mathelier, Hansie; Molina, Maria; Hanff, Thomas C; Mazurek, Jeremy A; Atluri, Pavan; Acker, Michael A; Rame, J Eduardo; Margulies, Kenneth B; Goldberg, Lee R; Jessup, Mariell

    2016-04-15

    Sudden cardiac death (SCD) is a common cause of death in the general population, occurring in 300,000 to 350,000 people in the United States alone. Currently, there are no data supporting implantable cardioverter-defibrillator therapy in patients who underwent orthotopic heart transplant (OHT) with low left ventricular ejection fraction (LVEF). In this retrospective study, we included all patients who underwent primary OHT at our institution from 2007 to 2013. We compared the cause of death in patients who underwent OHT and evaluated the correlation of the cause of death and the patients' LVEF. Our objectives were to determine whether patients who underwent OHT with LVEF 6 months after OHT. Surviving patients had higher LVEF compared with deceased patients (64 ± 7% and 50 ± 24%, respectively, p ≤0.001). In all, 10 (25%) of the deceased patients died suddenly, 9 (23%) from sepsis, and 8 (20%) from malignancy. Of the 11 deceased patients with LVEF ≤35%, 2 patients (18%) died suddenly compared with 9 SCDs among the 29 deceased patients (31%) with LVEF >35% (p = 0.54). In conclusion, patients who underwent OHT who died were more likely to have LVEF <35%, and a quarter of the deceased patients who underwent OHT died suddenly. A reduced LVEF was not associated with an increased risk of SCD. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  15. Influence of atrial fibrillation on the mortality of patients with heart failure with preserved ejection fraction.

    Science.gov (United States)

    Franco, Jonathan; Formiga, Francesc; Cepeda, Jose; Llacer, Pau; Arévalo-Lorido, Juan; Cerqueiro, Jose; González-Franco, Alvaro; Epelde, Francesc; Manzano, Luis; Montero Pérez-Barquero, Manuel

    2018-05-23

    The impact of atrial fibrillation (AF) on the prognosis of heart failure with preserved ejection fraction (HFpEF) is still the subject of debate. We analysed the influence of AF on the prognosis on mortality and readmission in patients with HFpEF. Prospective observational study in 1,971 patients with HFpEF, who were admitted for acute heart failure. Patients were divided into 2 groups according to the presence or absence of AF. We analysed mortality, readmissions and combined mortality/readmissions at one year follow-up. A total of 1,177 (59%) patients had AF, mean age 80.3 (7.8) years and 1,233 (63%) were women. Patients with HFpEF and AF were older, female, greater valvular aetiology and lower comorbidity measured by the Charlson index. At the one year follow-up, 430 (22%) patients had died and 840 (43%) had been readmitted. In the 2 groups analysed, there was no difference in all-cause mortality (22 vs. 21%; P=.739, AF vs. no-AF, respectively) or cardiovascular causes (9.6 vs. 8.2%; P=.739, AF vs. no-AF, respectively). In the multivariable analysis, factors associated with higher mortality were: age, male, valvular aetiology, uric acid, and comorbidity. In the analysis of the subgroup with HFpEF with AF, the presence of chronic AF compared to de novo AF was associated with higher mortality (HR 1,716; 95% CI 1,099-2,681; P=.018). In patients with HFpEF, the presence of AF is frequent. During the one-year follow-up, the presence of AF does not influence mortality or readmissions in patients with HFpEF. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  16. The importance of integrated left atrial evaluation: From hypertension to heart failure with preserved ejection fraction.

    Science.gov (United States)

    Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe

    2018-02-01

    Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.

  17. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, N.; Yonekura, Y.; Yamamoto, K. (Kyoto Univ. (Japan). Hospital)

    1981-03-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time.

  18. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Yonekura, Yoshiharu; Yamamoto, Kazutaka

    1981-01-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time. (author)

  19. Effects of supervised exercise and dietary nitrate in older adults with controlled hypertension and/or heart failure with preserved ejection fraction.

    Science.gov (United States)

    Shaltout, Hossam A; Eggebeen, Joel; Marsh, Anthony P; Brubaker, Peter H; Laurienti, Paul J; Burdette, Jonathan H; Basu, Swati; Morgan, Ashley; Dos Santos, Patricia C; Norris, James L; Morgan, Timothy M; Miller, Gary D; Rejeski, W Jack; Hawfield, Amret T; Diz, Debra I; Becton, J Thomas; Kim-Shapiro, Daniel B; Kitzman, Dalane W

    2017-09-30

    Aerobic exercise training is an effective therapy to improve peak aerobic power (peak VO 2 ) in individuals with hypertension (HTN, AHA/ACC class A) and heart failure patients with preserved ejection fraction (HFpEF). High nitrate containing beetroot juice (BRJ) also improves sub-maximal endurance and decreases blood pressure in both HTN and HFpEF. We hypothesized that combining an aerobic exercise and dietary nitrate intervention would result in additive or even synergistic positive effects on exercise tolerance and blood pressure in HTN or HFpEF. We report results from two pilot studies examining the effects of supervised aerobic exercise combined with dietary nitrate in patients with controlled HTN (n = 26, average age 65 ± 5 years) and in patients with HFpEF (n = 20, average age 69 ± 7 years). All patients underwent an aerobic exercise training regimen; half were randomly assigned to consume a high nitrate-containing beet juice beverage (BRJ containing 6.1 mmol nitrate for the HFpEF study consumed three times a week and 8 mmol nitrate for the HTN study consumed daily) while the other half consumed a beet juice beverage with the nitrate removed (placebo). The main result was that there was no added benefit observed for any outcomes when comparing BRJ to placebo in either HTN or HFpEF patients undergoing exercise training (p ≥ 0.14). There were within-group benefits. In the pilot study in patients with HFpEF, aerobic endurance (primary outcome), defined as the exercise time to volitional exhaustion during submaximal cycling at 75% of maximal power output, improved during exercise training within each group from baseline to end of study, 369 ± 149 s vs 520 ± 257 s (p = 0.04) for the placebo group and 384 ± 129 s vs 483 ± 258 s for the BRJ group (p = 0.15). Resting systolic blood pressure in patients with HFpEF also improved during exercise training in both groups, 136 ± 16 mm Hg vs 122 ± 3 mm Hg for the placebo group (p

  20. Preoperative prediction of reversible myocardial asynergy by postexercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Rozanski, A.; Berman, D.; Gray, R.; Diamond, G.; Raymond, M.; Prause, J.; Maddahi, J.; Swan, H.J.; Matloff, J.

    1982-01-01

    Myocardial asynergy is sometimes reversed by coronary bypass, and a noninvasive method of predicting which assess are reversible would be desirable. To assess whether changes in myocardial wall motion observed immediately after exercise can differentiate reversible from nonreversible myocardial asynergy, we evaluated 53 patients by radionuclide ventriculography before and after exercise and again at rest after coronary bypass surgery. Preoperative improvement in wall motion immediately after exercise was highly predictive of the surgical outcome (average chance-corrected agreement, 91 per cent). At surgery the asynergic segments that had improved after exercise were free of grossly apparent epicardial scarring. The accuracy of these predictions for postoperative improvement was significantly greater (P less than 0.01) than that of analysis of Q waves on resting electrocardiography (average chance-corrected agreement, 40 per cent). In contrast, preoperative changes in left ventricular ejection fraction after exercise were not predictive of postoperative resting ejection fraction. We conclude that postexercise radionuclide ventriculography can be used to identify reversible resting myocardial asynergy. This test should prove effective in predicting which patients with myocardial asynergy are most likely to benefit from aortocoronary revascularization

  1. Barriers to Beta-Blocker Use and Up-Titration Among Patients with Heart Failure with Reduced Ejection Fraction.

    Science.gov (United States)

    Levitan, Emily B; Van Dyke, Melissa K; Loop, Matthew Shane; O'Beirne, Ronan; Safford, Monika M

    2017-12-01

    For patients with heart failure with reduced ejection fraction (HFrEF), guidelines recommend use of beta-blockers with gradual up-titration. However, many patients with HFrEF do not use beta-blockers and up-titration is rare. Our purpose was to identify and rank barriers to beta-blocker use and up-titration from the perspective of primary care physicians. We conducted 4 moderated, structured group discussions among 19 primary care physicians using the nominal group technique; 16 participants also completed a survey. Participants generated lists of barriers to beta-blocker use and up-titration among patients with HFrEF. Each participant had six votes with three votes assigned to the item ranked most important, two to the second most important item, and one to the third most important item. Investigators characterized items into themes. The percentage of available votes was calculated for each theme. Fifteen of 16 participating primary care physicians who completed the survey reported that management of beta-blockers was their responsibility. Treatment/side effects, particularly hypotension, were identified as the most important barrier for beta-blocker use (72% of available votes) followed by polypharmacy (11%), healthcare system barriers (10%), and comorbidities (6%). Barriers to up-titration included treatment/side effects (49% of available votes), patient communication/buy-in (21%), polypharmacy (13%), and healthcare system barriers (8%). Many barriers to guideline concordant use of beta-blockers among patients with HFrEF identified by primary care providers are not readily modifiable. Addressing these barriers may require development, testing, and dissemination of protocols for beta-blocker initiation and up-titration that are safe and appropriate in primary care.

  2. Changes with age in left ventricular function and volumes at rest and postexercise in postmenopausal women

    International Nuclear Information System (INIS)

    Yamada, Kiyoyasu; Isobe, Satoshi; Hirai, Makoto

    2006-01-01

    In postmenopausal women, it has been reported that the plasma estrogen levels diminish immediately after menopause, and that this phenomenon affects left ventricular (LV) function and volumes. However, the effects of age on LV function and volumes for a relatively short period in the postmenopausal women remain to be established. Electrocardiographically gated-myocardial single-photon emission computed tomography (SPECT) has recently provided accurate estimations of perfusion, cardiac systolic and diastolic functions. We investigated the age-related changes in LV function and volumes in postmenopausal women using electrocardiographically gated-myocardial scintigraphy. Twenty-two consecutive healthy postmenopausal women (mean age of 63.8±9.4 years, from 42 to 77 years) without cardiac disease underwent stress/rest technetium-99m tetrofosmin gated-myocardial SPECT with 16 frames per cardiac cycle at baseline and follow-up (1.0±0.3 years later). LV ejection fraction (LVEF) and LV volumes were calculated by quantitative gated SPECT (QGS) software. Fourier series were retained for the analysis of the volume curve. From this volume curve, we derived the following diastolic indices: peak filling rate (PFR) and time to PFR (TPFR). End-systolic volume index (ESVI) significantly decreased at postexercise (p=0.02) and tended to decrease at rest (p=0.06) from the baseline to the follow-up study. LVEF significantly increased at both postexercise (p=0.01) and rest (p=0.03) from the baseline to the follow-up study. The TPFR at rest tended to be prolonged from the baseline to the follow-up study (p=0.07). The absolute increase in LVEF at postexercise tended to decrease with age [4.8% (50s) vs. 3.4% (60s) vs. 1.2% (70s)]. An age-related change in cardiac performance is apparent at an approximately 1 year follow-up in postmenopausal women. In particular, the increase in LV systolic function tends to show the greatest value in the 50s subjects among the 3 generations. (author)

  3. Jet behaviors and ejection mode recognition of electrohydrodynamic direct-write

    Science.gov (United States)

    Zheng, Jianyi; Zhang, Kai; Jiang, Jiaxin; Wang, Xiang; Li, Wenwang; Liu, Yifang; Liu, Juan; Zheng, Gaofeng

    2018-01-01

    By introducing image recognition and micro-current testing, jet behavior research was conducted, in which the real-time recognition of ejection mode was realized. To study the factors influencing ejection modes and the current variation trends under different modes, an Electrohydrodynamic Direct-Write (EDW) system with functions of current detection and ejection mode recognition was firstly built. Then a program was developed to recognize the jet modes. As the voltage applied to the metal tip increased, four jet ejection modes in EDW occurred: droplet ejection mode, Taylor cone ejection mode, retractive ejection mode and forked ejection mode. In this work, the corresponding relationship between the ejection modes and the effect on fiber deposition as well as current was studied. The real-time identification of ejection mode and detection of electrospinning current was realized. The results in this paper are contributed to enhancing the ejection stability, providing a good technical basis to produce continuous uniform nanofibers controllably.

  4. Comparison of exercise ECG and radionuclide ventriculography in the assessment of myocardial ischemia in patients with isolated stenoses of the left anterior descending artery

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Mildenberger, D.; Kaltenbach, M.; Standke, R.; Baum, R.P.; Tezak, S.; Maul, F.D.; Hoer, G.

    1988-01-01

    21 patients with LAD-stenoses of at least 70% and 21 patients with LAD-stenoses and additional intramural anterior wall infarctions were studied. 20 patients without heart disease or after successful transluminal coronary angioplasty and 18 patients with intramural anterior wall infarction after successful transluminal dilatation of the LAD (remaining stenosis maximal 30%) served as controls. The normal range of global and regional left ventricular ejection fraction response to exercise was defined based on the data of 25 further patients without relevant coronary heart disease. Thus, a decrease in global ejection fraction and regional wall motion abnormalities were judged pathological. All patients were comparable with respect to age, ejection fraction at rest and work load. Myocardial ischemia could be detected by the exercise ECG in 81% of all patients without infarction and in 71% of patients with infarction. The corresponding values for global left ventricular ejection fraction were 76% and 81%, respectively, and for regional ejection fraction 95% in both groups. No false-positive exercise ECGs were observed in the healthy controls and 2(11%) in the corresponding group with intramural infaction. The global ejection fraction was pathological in 1(5%) healthy subject without infarction and in 3(17%) corresponding patients with infarction. Sectorial analysis revealed 5 and 22%, respectively. Our findings suggest that the exercise ECG has a limited sensitivity to detect myocardial ischemia in patients with isolated LAD-stenoses and intramural myocardial infarction. Radionuclide ventriculography yields pathological values more often; however, false-positive results also occur more frequently. (orig.) [de

  5. Physiologic abnormalities of cardiac function in progressive systemic sclerosis with diffuse scleroderma

    International Nuclear Information System (INIS)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.; Steen, V.D.; Uretsky, B.F.; Owens, G.R.; Rodnan, G.P.

    1984-01-01

    To investigate cardiopulmonary function in progressive systemic sclerosis with diffuse scleroderma, we studied 26 patients with maximal exercise and redistribution thallium scans, rest and exercise radionuclide ventriculography, pulmonary-function testing, and chest roentgenography. Although only 6 patients had clinical evidence of cardiac involvement, 20 had abnormal thallium scans, including 10 with reversible exercise-induced defects and 18 with fixed defects (8 had both). Seven of the 10 patients who had exercise-induced defects and underwent cardiac catheterization had normal coronary angiograms. Mean resting left ventricular ejection fraction and mean resting right ventricular ejection fraction were lower in patients with post-exercise left ventricular thallium defect scores above the median (59 +/- 13 per cent vs. 69 +/- 6 per cent, and 36 +/- 12 per cent vs. 47 +/- 7 per cent, respectively). The authors conclude that in progressive systemic sclerosis with diffuse scleroderma, abnormalities of myocardial perfusion are common and appear to be due to a disturbance of the myocardial microcirculation. Both right and left ventricular dysfunction appear to be related to this circulatory disturbance, suggesting ischemically mediated injury

  6. Ejection experience in Serbian air force, 1990-2010

    Directory of Open Access Journals (Sweden)

    Pavlović Miroslav

    2014-01-01

    Full Text Available Background/Aim. Ejection injuries are the problem for air forces. The present risk for injuries is still too high, approximately 30-50%. This study was an effort to determine factors responsible for and contributing to injuries in the Serbian Air Force (SAF in the last two decades. Methods. All ejection cases in the SAF between 1990 and 2010 were analyzed. The collected data were: aircraft type, ejection seat generation, pilots ´ age and experience, causes of ejection, aeronautical parameters, the condition of aircraft control and types of injuries. For ease of comparison the U.S. Air Force Safety Regulation was used to define of major injuries: hospitalization for 5 days or more, loss of consciousness for over 5 min, bone fracture, joint dislocation, injury to any internal organ, any third-degree burn, or second-degree burn over 5% of the body surface area. Results. There were 52 ejections (51 pilots and 1 mechanic on 44 airplanes. The ejected persons were from 22 to 46 years, average 32 years. Major injuries were present in 25.49% cases. Of all the ejected pilots 9.61% had fractures of thoracic spine, 11.53% fractures of legs, 3.48% fractures of arms. Of all major injuries, fractures of thoracic spine were 38.46%. None of the pilots had experienced ejection previously. Conclusion. Our results suggest to obligatory take preventive measures: magnetic resonance imaging (MRI scan must be included in the standard pilot selection procedure and procedure after ejection. Physical conditioning of pilots has to be improved. Training on ejection trainer has to be accomplished, too.

  7. Development of a DNBR evaluation method for the CEA ejection accident in SMART core

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Dae Hyun; Yoo, Y. J.; In, W. K.; Chang, M. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-12-01

    A methodology applicable to the analysis of the CEA ejection accident in SMART is developed for the evaluation of the fraction of fuel failure caused by DNB. The transient behavior of the core thermal-hydraulic conditions is calculated by the subchannel analysis code MATRA. The minimum DNBR during the accident is calculated by KRB-1 CHF correlation considering the 1/8 symmetry of hot assembly. The variation of hot assembly power during the accident is simulated by the LTC(Limiting transient Curve) which is determined from the analysis of power distribution data resulting from the three-dimensional core dynamics calculations. The initial condition of the accident is determined by considering LOC(Limiting Conditions for Operation) of SMART core. Two different methodologies for the evaluation of DNB failure rate are established; a deterministic method based on the DNB envelope, and a probabilistic method based on the DNB probability of each fuel rod. The methodology developed in this study is applied to the analysis of CEA ejection accident in the preliminary design core of SMART. As the result, the fractions of DNB fuel failure by the deterministic method and the probabilistic method are calculated as 38.7% and 7.8%, respectively. 16 refs., 16 figs., 5 tabs. (Author)

  8. 14 CFR 91.1057 - Flight, duty and rest time requirements: All crewmembers.

    Science.gov (United States)

    2010-01-01

    ... RULES Fractional Ownership Operations Program Management § 91.1057 Flight, duty and rest time... cabin-safety-related responsibilities. Multi-time zone flight means an easterly or westerly flight or... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight, duty and rest time requirements...

  9. Pharmacological radionuclide ventriculography for detection of myocardial contractile reserve in patients after myocardial infarction: head-to-head comparison of low dose dobutamine and low dose dypiridamole

    International Nuclear Information System (INIS)

    Petrasinovic, Z.; Ostojic, M.; Beleslin, B.; Stojkovic, S.; Nedeljkovic, M.; Stankovic, G.; Dikic, A.; Pavlovic, S.; Sobic, D.

    2002-01-01

    Background. Low dose pharmacological stress echocardiography with either dobutamine or dipyridamole infusion has been proposed for recognition of myocardial viability. However, dependence on adequate acoustic window, observer experience, and the mild degree of wall motion changes make the viability assessment by stress echocardiography especially bothersome. The objective of the study was to evaluate the ability of low dose dobutamine and low dose dipyridamole radionuclide ventriculography to detect contractile reserve in patients after myocardial infarction and functional recovery after coronary angioplasty. Methods. The study group consisted of 20 consecutive patients (52±10 years, 17 male) with previous myocardial infarction and resting regional dyssynergy, in whom diagnostic cardiac catheterization revealed significant one-vessel coronary artery stenosis suitable for angioplasty. Each patient underwent equilibrium 99m-Tc radionuclide ventriculography which was performed at rest and during low dose dipyridamole (0.28 mg/kg over 2 minutes) and low dose dobutamine infusion (up to 10 mcg/kg/min). Left ventricular global and regional ejection fractions were determined. Increase of regional ejection fraction for >5% (inferoapical and posterolateral regions) or >10% (anteroseptal regions) during low dose dobutamine and dipyridamole in infarcted regions, as well as in the follow up period, was considered as index of contractile reserve. After 8 weeks of successful angioplasty, resting radionuclide ventriculography was repeated in all patients in order to identify functional recovery of the infarct zone. Results. Out of the 180 analyzed segments (20x9), 90 regional ejection fractions have shown depressed contractility. The mean of the regional ejection fractions showing depressed contractility increased from the resting value of 34±12% to 42±14% in the follow-up period (p=0.06). Of the 90 with baseline dyssynergy, 46 were responders during low-dose dobutamine (51

  10. Equilibrium radionuclide ventriculography in male patients after transmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Nestaval, A; Stanek, V; Malek, I; Kidery, J; Runczik, I [Institut pro Klinickou a Experimentalni Medicinu, Prague (Czechoslovakia); Cernoch, V; Oppelt, A [Institut pro Dalsi Vzdelavani Lekaru a Farmaceutu, Prague (Czechoslovakia)

    1982-12-17

    The ejection fraction of the left ventricle was measured using the method of equilibrium radionuclide ventriculography in 10 healthy males and 57 males after the first transmural myocardial infarction. The examination was effected 4 to 7 months after the event and the sample is representative for males after myocardial infarction who are younger than 65 years and show no signs of heart insufficiency by the time of examination. The resting value of the ejection fraction was 63+-5% in healthy males, 54+-7% in patients with uncomplicated myocardial infarction and 37+-8% in patients with clinical manifestations of heart insufficiency in acute phase. The differences between the groups are statistically significant. In patients with anteroseptal localization of myocardial infarction there was a negative correlation between the ejection fraction on the one hand and the sum of the voltages of Q waves in precordial ECG map and the maximum value of serum creatine kinase in acute phase on the other. The ejection fraction was in correlation to the degree of pulmonary hypertension measured in equal phase during exercise. The ejection fraction was measured in 31 patients under the working load of 50 W; significant changes were not found in healthy males or in patients after myocardial infarction. No changes were found when the state just before discharge from the hospital was compared with his state 6 months after myocardial infarction. The results obtained in compensated patients showed a relative stability of the value of the ejection fraction both during the first 6 months after discharge and under a mild working load. A comparison between the indicators in acute phase and hemodynamic examination after 6 months shows that the value of the ejection fraction is a sensitive indicator of the extent of necrosis and functional lesion of the left ventricle.

  11. Effect of selective and nonselective beta-blockers on resting energy production rate and total body substrate utilization in chronic heart failure.

    Science.gov (United States)

    Podbregar, Matej; Voga, Gorazd

    2002-12-01

    In chronic heart failure (CHF) beta-blockers reduce myocardial oxygen consumption and improve myocardial efficiency by shifting myocardial substrate utilization from increased free fatty acid oxidation to increased glucose oxidation. The effect of selective and nonselective beta-blockers on total body resting energy production rate (EPR) and substrate utilization is not known. Twenty-six noncachectic patients with moderately severe heart failure (New York Heart Association class II or III, left ventricular ejection fraction < 0.40) were treated with carvedilol (37.5 +/- 13.5 mg/12 h) or bisoprolol (5.4 +/- 3.0 mg/d) for 6 months. Indirect calorimetry was performed before and after 6 months of treatment. Resting EPR was decreased in carvedilol (5.021 +/- 0.803 to 4.552 +/- 0.615 kJ/min, P <.001) and bisoprolol group (5.230 +/- 0.828 to 4.978 +/- 0.640 kJ/min, P <.05; nonsignificant difference between groups). Lipid oxidation rate decreased in carvedilol and remained unchanged in bisoprolol group (2.4 +/- 1.4 to 1.5 +/- 0.9 mg m(2)/kg min versus 2.7 +/- 1.1 to 2.5 +/- 1.1 mg m(2)/kg min, P <.05). Glucose oxidation rate was increased only in carvedilol (2.6 +/- 1.4 to 4.4 +/- 1.6 mg m(2)/kg min, P <.05), but did not change in bisoprolol group. Both selective and nonselective beta-blockers reduce total body resting EPR in noncachectic CHF patients. Carvedilol compared to bisoprolol shifts total body substrate utilization from lipid to glucose oxidation.

  12. A method to identify early ventricular dysfunction using resting gated blood pool scans (GBPS) in patients with coronary artery disease (CAD)

    International Nuclear Information System (INIS)

    Schwarzberg, R.J.; Seldin, D.W.; Johnson, L.L.; Alderson, P.O.

    1984-01-01

    To determine the sensitivity of regional 1st and 2nd time derivative (1DV, 2DV) images to assess ventricular function (VF) in CAD, the resting GBPS of 8 normal patients (pts) and 20 pts with CAD who had coronary angiography and contrast ventriculography (CV) were analyzed. The 1DV and 2DV of the systolic time-activity curve were determined for each left ventricular pixel in the GBPS. These values were displayed as functional images that were reviewed by three readers to determine the presence of regional abnormalities. No regional abnormalities were seen in the conventional GBPS or 1DV or 2DV images of the 8 normal pts. Regional GBPS and DV image abnormalities were seen in all 10 pts with CAD and abnormal wall motion by CV. The DV image abnormalities were in the distribution of 18/22 coronary arteries (CA) with ≥50% stenoses; 2 of these regions showed normal wall motion by CV and conventional GBPS. DV images were abnormal in 2/8 CAs without significant stenoses. In addition, regional DV image abnormalities were present in 9 of 10 pts with CAD who had normal wall motion and global ejection fraction by both CV and resting GBPS. These 10 pts showed regional abnormalities in the distribution of 13/15 CAs with significant stenoses and 2/15 CAs without such stenoses. The results suggest that time derivative functional images derived from resting GBPS provide a more sensitive means for detecting regional left ventricular dysfunction than several other current methods, especially in pts with mild CAD

  13. The Restoration of Chronotropic CompEtence in Heart Failure PatientS with Normal Ejection FracTion (RESET) Study: Rationale and Design

    Science.gov (United States)

    Kass, David A.; Kitzman, Dalane W.; Alvarez, Guy E.

    2009-01-01

    Background Heart failure with preserved ejection fraction (HFpEF) is the predominant form of HF among the elderly and in women. However, there are few if any evidence-based therapeutic options for HFpEF. The chief complaint of HFpEF is reduced tolerance to physical exertion. Recent data revealed that one potential mechanism of exertional intolerance in HFpEF patients is inadequate chronotropic response. Although there is considerable evidence demonstrating the benefits of rate-adaptive pacing (RAP) provided from implantable cardiac devices in patients with an impaired chronotropic response, the effect of RAP in HFpEF is unknown. Methods and Results The RESET study is a prospective, multi-center, double-blind, randomized with stratification, study assessing the effect of RAP on peak VO2 and quality of life. RAP therapy will be evaluated in a cross-over paired fashion for each patient within each study stratum. Study strata are based on patient beta-blocker usage at time of enrollment. The study is powered to assess the impact of pacing independently in both strata. Conclusions The RESET study seeks to evaluate the potential benefit of RAP in patients with symptomatic mild to moderate HFpEF and chronotropic impairment. Study enrollment began in July 2008. PMID:20123314

  14. The BEAUTIFUL study: randomized trial of ivabradine in patients with stable coronary artery disease and left ventricular systolic dysfunction - baseline characteristics of the study population

    DEFF Research Database (Denmark)

    NN, NN; Ferrari, R; Ford, I

    2008-01-01

    diabetes, and 40% had metabolic syndrome. Mean ejection fraction was 32% and resting heart rate was 71.6 bpm. Concomitant medications included beta-blockers (87%), renin-angiotensin system agents (89%), antithrombotic agents (94%), and lipid-lowering agents (76%). CONCLUSIONS: Main results from BEAUTIFUL...

  15. Multifraction dose response of growing and resting phase hair follicles

    International Nuclear Information System (INIS)

    Vegesna, V.; Withers, H.R.

    1987-01-01

    It has been established in both the clinic and the laboratory that there is a differentiation response to changes in dose per fraction in early and late responding tissues. To study one possible biological reason for differences in early and late responses. The authors selected one kind of cellular entity, the hair follicle, in two different phases of mitotic activity. The follicles are usually in a resting phase (7-12 wks), but mitotic activity can be initiated by plucking the club hairs. This was done on one half of the thorax and then exposing mice to doses of radiation (cesium gamma-ray). Dose responses for epilation between growing (early) and resting (late) follicles were compared for the same mouse. The fractionated response was studied by reducing the dose down to 2.5 Gy/fx. As the literature suggests, the total dose tolerated by a resting (late) follicle increased more than that for a growing (early) follicle

  16. Left ventricular global longitudinal strain is predictive of all-cause mortality independent of aortic stenosis severity and ejection fraction.

    Science.gov (United States)

    Ng, Arnold C T; Prihadi, Edgard A; Antoni, M Louisa; Bertini, Matteo; Ewe, See Hooi; Ajmone Marsan, Nina; Leung, Dominic Y; Delgado, Victoria; Bax, Jeroen J

    2017-07-28

    Left ventricular (LV) global longitudinal strain (GLS) may identify subclinical myocardial dysfunction in patients with aortic stenosis (AS). The aims of the present retrospective single centre study were to determine the independent prognostic value of LV GLS over LV ejection fraction (EF) and the role of LV GLS to further risk stratify severe AS patients before aortic valve replacement. A total of 688 patients (median age 72 years, 61.2% men) with mild (n = 130), moderate (n = 264) and severe AS (n = 294) were included. LV GLS was determined by 2D speckle tracking echocardiography. A total of 114 (16.6%) patients died before surgery during the study. When patients with severe AS and normal LVEF were dichotomized based on the median LV GLS value (-14.0%), patients with normal LVEF and 'preserved' LV GLS of ≤ -14% had significantly higher survival than patients with 'impaired' LV GLS of > -14%. There was no difference in survival between patients with normal LVEF but 'impaired' LV GLS ( > -14%) and patients with impaired LVEF (log-rank P = 0.34). LV GLS was independently associated with all-cause mortality on multivariable Cox regression analysis (hazard ratio 1.17, 95% confidence interval 1.09-1.26; P optimal timing of aortic valve replacement. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  17. Ultrasound - Aided ejection in micro injection molding

    Science.gov (United States)

    Masato, D.; Sorgato, M.; Lucchetta, G.

    2018-05-01

    In this work, an ultrasound-aided ejection system was designed and tested for different polymers (PS, COC and POM) and mold topographies. The proposed solution aims at reducing the ejection friction by decreasing the adhesion component of the frictional force, which is controlled by the contact area developed during the filling stage of the injection molding process. The experimental results indicate a positive effect of ultrasound vibration on the friction force values, with a maximum reduction of 16. Moreover, it is demonstrated that the ultrasound effect is strictly related to both polymer selection and mold roughness. The combined effect on the ejection force of mold surface roughness, melt viscosity during filling and polymer elastic modulus at ejection was modeled to the experimental data, in order to demonstrate that the effect of ultrasound vibration on the ejection friction reduction is due to the heating of the contact interface and the consequent reduction of the polymer elastic modulus.

  18. Mass Ejection from the Remnant of a Binary Neutron Star Merger: Viscous-radiation Hydrodynamics Study

    Science.gov (United States)

    Fujibayashi, Sho; Kiuchi, Kenta; Nishimura, Nobuya; Sekiguchi, Yuichiro; Shibata, Masaru

    2018-06-01

    We perform long-term general relativistic neutrino radiation hydrodynamics simulations (in axisymmetry) for a massive neutron star (MNS) surrounded by a torus, which is a canonical remnant formed after the binary neutron star merger. We take into account the effects of viscosity, which is likely to arise in the merger remnant due to magnetohydrodynamical turbulence. The viscous effect plays key roles for the mass ejection from the remnant in two phases of the evolution. In the first t ≲ 10 ms, a differential rotation state of the MNS is changed to a rigidly rotating state. A shock wave caused by the variation of its quasi-equilibrium state induces significant mass ejection of mass ∼(0.5–2.0) × {10}-2 {M}ȯ for the α-viscosity parameter of 0.01–0.04. For the longer-term evolution with ∼0.1–10 s, a significant fraction of the torus material is ejected. We find that the total mass of the viscosity-driven ejecta (≳ {10}-2 {M}ȯ ) could dominate over that of the dynamical ejecta (≲ {10}-2 {M}ȯ ). The electron fraction, Y e , of the ejecta is always high enough (Y e ≳ 0.25) that this post-merger ejecta is lanthanide-poor; hence, the opacity of the ejecta is likely to be ∼10–100 times lower than that of the dynamical ejecta. This indicates that the electromagnetic signal from the ejecta would be rapidly evolving, bright, and blue if it is observed from a small viewing angle (≲45°) for which the effect of the dynamical ejecta is minor.

  19. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    Science.gov (United States)

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEFstatistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a stress myocardial perfusion imaging variables. This model provides reliable LVEF estimations, comparable to those from (201)Tl gated SPET, and can enhance the clinical performance of the latter.

  20. Space weather and coronal mass ejections

    CERN Document Server

    Howard, Tim

    2013-01-01

    Space weather has attracted a lot of attention in recent times. Severe space weather can disrupt spacecraft, and on Earth can be the cause of power outages and power station failure. It also presents a radiation hazard for airline passengers and astronauts. These ""magnetic storms"" are most commonly caused by coronal mass ejections, or CMES, which are large eruptions of plasma and magnetic field from the Sun that can reach speeds of several thousand km/s. In this SpringerBrief, Space Weather and Coronal Mass Ejections, author Timothy Howard briefly introduces the coronal mass ejection, its sc

  1. 14 CFR 91.1059 - Flight time limitations and rest requirements: One or two pilot crews.

    Science.gov (United States)

    2010-01-01

    ... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1059 Flight time... Rest 10 Hours 12 Hours. (6) Minimum After Duty Rest Period for Multi-Time Zone Flights 14 Hours 18... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight time limitations and rest...

  2. Clinical use of ultrashort-lived radionuclide krypton-81m for noninvasive analysis of right ventricular performance in normal subjects and patients with right ventricular dysfunction

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Spielmann, R.P.; Wasmus, G.; Mathey, D.G.; Montz, R.; Bleifeld, W.H.

    1985-01-01

    The ultrashort-lived radionuclide krypton-81m, eluted in 5% dextrose from a bedside rubidium-81m generator, was intravenously infused for rapid imaging of the right-sided heart chambers in the right anterior oblique projection adjusted for optimal right atrioventricular separation. Left-sided heart and lung background was minimized by rapid decay and efficient exhalation of krypton-81m, requiring no algorithm for background correction. A double region of interest method decreased the variability in the assessment of ejection fraction to 5%. In 10 normal subjects, 11 patients with pulmonary hypertension, 4 patients with right ventricular outflow tract obstruction and 4 patients with right ventricular infarction, right ventricular ejection fraction determined by krypton-81m equilibrium blood pool imaging ranged from 14 to 76%. The correlation between these values and those determined by cineangiography according to Simpson's rule was close: r . 0.93 for all data points, r . 0.92 for studies at rest and r . 0.93 for exercise studies. Exercise-related changes in right ventricular function revealed a disturbed functional reserve with pulmonary hypertension and right ventricular infarction, whereas in compensated right ventricular outflow tract obstruction there was a physiologic increase in ejection fraction with exercise. Thus, equilibrium-gated right ventricular imaging using ultrashort-lived krypton-81m is a simple, accurate and reproducible method with potential for serial assessment of right ventricular ejection fraction in a variety of right ventricular anatomic and functional abnormalities, both at rest and during exercise. Advantages of this method include an extremely low radiation dose to patients and clear right atrioventricular separation without the need to correct for background activity

  3. Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

    International Nuclear Information System (INIS)

    Bartlett, M.L.; Seaton, D.; McEwan, L.; Fong, W.

    2001-01-01

    Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels ''greyed out''. This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively). (orig.)

  4. Long-term and clinical profile of heart failure with recovered ejection fraction in a non-tertiary hospital.

    Science.gov (United States)

    Martínez-Mateo, Virgilio; Fernández-Anguita, Manuel; Cejudo, Laura; Martín-Barrios, Eugenia; Paule, Antonio J

    2018-06-05

    Heart failure (HF) with recovered ejection fraction (EF) is emerging as a different HF subtype. There is little information about his clinical profile in hospitals that are not a reference. We analysed characteristics and prognosis in patients with recovered HF followed prospectively in the HF Unit of a non-tertiary hospital. A total of 431 patients with HF with reduced EF were followed (median 50 months, 79.3% males, mean age 70.3±12.2years). Of the patients, 26.9% (N 116) recovered EF, mainly in the first year of follow-up (76.7%). Compared with patients that did not recovered EF in the follow-up, they were younger, rate of ischemic origin of cardiomyopathy was less frequent and presented less comorbidity. Mortality was lower in patients with recovered HF (survival median of 85.2±2.1 vs. 74.2±1.9 months [log-rank χ 2 11.5, P=0.001], hazard ratio 0.37, 95% confidence interval [CI]: 0.21-0.67, P=0.002). Aetiology of deaths was not mainly secondary to HF. Younger age of 68 years (odds ratio [OR] 0-98, 95% CI: 0.96-0,99; P=0.025), ischemic origin (OR 1.12, 95% CI: 1.01-1.21; P=0.003) and use of aldosterone antagonists (OR 1.89, 95% CI: 1.09-3.26; P=0.023) were the variables independently associated to normalisation of EF. HF with recovered EF is a frequent phenomenon. It has a more favourable clinical course, prognosis and basal characteristics than HF with persistent reduced EF. Further studies are needed to identify natural history and optimal medications for HF-recovered patients. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  5. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

    Science.gov (United States)

    Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna

    2017-12-01

    Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.

  6. Reversible Congestive Heart Failure after Percutaneous Closure of a Large PDA in a 34-year-old Woman

    Directory of Open Access Journals (Sweden)

    Ramazan Kargın

    2010-08-01

    Full Text Available Patent ductus arteriosus is a congenital heart disease which can cause chronic volume overload leading to congestive heart failure. A 34-year-old woman with rest dyspnea was found to have patent ductus arteriosus and echocardiogram revealed a markedly dilated left ventricle (8.9 cm and severely-compromised left ventricle systolic functions (ejection fraction~24%. The patent ductus arteriosus was successfully closed percutaneously with Amplatzer occluder device. The patient was discharged on optimal dosages of ramipril, metoprolol, furosemide, spiranolactone and aspirin. On the follow-up after 18 months, the symptoms were found to have regressed and echocardiographic parameters improved (ejection fraction~55%.

  7. On the mass ejected by supernova explosions

    International Nuclear Information System (INIS)

    Bohigas, J.

    1984-01-01

    A simple model is developed in order to calculate the mass ejected by superonovae. We find that the 185, 1006, 1572 and 1604 AD events, all of them classified as either probable or possible type I supernovae, ejected between 0.1 and 0.4 solar masses with an expansion velocity of roughly 10,000 km s -1 . This range of masses suggests that a collapsed object is at the center of the remnants produced by these supernovae if the precursor was a white dwarf whose mass was closed to the Chandrasekhar limit. For the Crab we obtain an ejected mass of 0.45 Msub(sun) and point out that this value is not in contradiction with a proposal in which the moderate helium stars are good candidates for producing this kind of supernovae. Finally we obtain an ejected mass of 3.1 Msub(sun) for Cas A, indicating that a type II event produced this remnant. This ejected mass is closed to what would be expected for a progenitor like an OBN star. (author)

  8. Cost-effectiveness of sacubitril/valsartan versus enalapril in patients with heart failure and reduced ejection fraction.

    Science.gov (United States)

    Liang, Lin; Bin-Chia Wu, David; Aziz, Mohamed Ismail Abdul; Wong, Raymond; Sim, David; Leong, Kui Toh Gerard; Wei, Yong Quek; Tan, Doreen; Ng, Kwong

    2018-02-01

    Sacubitril/valsartan reduces cardiovascular death and hospitalizations for heart failure (HF). However, decision-makers need to determine whether its benefits are worth the additional costs, given the low-cost generic status of traditional standard of care. To evaluate the cost-effectiveness of sacubitril/valsartan compared to enalapril in patients with HF and reduced ejection fraction, from the Singapore healthcare payer perspective. A Markov model was developed to project clinical and economic outcomes of sacubitril/valsartan vs enalapril for 66-year-old patients with HF over 10 years. Key health states included New York Heart Association classes I-IV and deaths; patients in each state incurred a monthly risk of hospitalization for HF and cardiovascular death. Sacubitril/valsartan benefits were modeled by applying the hazard ratios (HRs) in PARADIGM-HF trial to baseline probabilities. Primary model outcomes were total and incremental costs and quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for sacubitril/valsartan relative to enalapril Results: Compared to enalapril, sacubitril/valsartan was associated with an ICER of SGD 74,592 (USD 55,198) per QALY gained. A major driver of cost-effectiveness was the cardiovascular mortality benefit of sacubitril/valsartan. The uncertainty of this treatment benefit in the Asian sub-group was tested in sensitivity analyses using a HR of 1 as an upper limit, where the ICERs ranged from SGD 41,019 (USD 30,354) to SGD 1,447,103 (USD 1,070,856) per QALY gained. Probabilistic sensitivity analyses showed the probability of sacubitril/valsartan being cost-effective was below 1%, 12%, and 71% at SGD 20,000, SGD 50,000, and SGD 100,000 per QALY gained, respectively. At the current daily price sacubitril/valsartan may not represent good value for limited healthcare dollars compared to enalapril in reducing cardiovascular morbidity and mortality in HF in the Singapore healthcare setting. This study

  9. Ejection of rocky and icy material from binary star systems: implications for the origin and composition of 1I/`Oumuamua

    Science.gov (United States)

    Jackson, Alan P.; Tamayo, Daniel; Hammond, Noah; Ali-Dib, Mohamad; Rein, Hanno

    2018-06-01

    In single-star systems like our own Solar system, comets dominate the mass budget of bodies ejected into interstellar space, since they form further away and are less tightly bound. However, 1I/`Oumuamua, the first interstellar object detected, appears asteroidal in its spectra and lack of detectable activity. We argue that the galactic budget of interstellar objects like 1I/`Oumuamua should be dominated by planetesimal material ejected during planet formation in circumbinary systems, rather than in single-star systems or widely separated binaries. We further show that in circumbinary systems, rocky bodies should be ejected in comparable numbers to icy ones. This suggests that a substantial fraction of interstellar objects discovered in future should display an active coma. We find that the rocky population, of which 1I/`Oumuamua seems to be a member, should be predominantly sourced from A-type and late B-star binaries.

  10. Pharmacodynamic and Pharmacokinetic Profiles of Sacubitril/Valsartan (LCZ696) in Patients with Heart Failure and Reduced Ejection Fraction.

    Science.gov (United States)

    Kobalava, Zhanna; Kotovskaya, Yulia; Averkov, Oleg; Pavlikova, Elena; Moiseev, Valentine; Albrecht, Diego; Chandra, Priya; Ayalasomayajula, Surya; Prescott, Margaret F; Pal, Parasar; Langenickel, Thomas H; Jordaan, Pierre; Rajman, Iris

    2016-08-01

    Concomitant renin-angiotensin-aldosterone system blockade and natriuretic peptide system enhancement may provide unique therapeutic benefits to patients with heart failure and reduced ejection fraction (HFrEF). This study assessed the pharmacodynamics and pharmacokinetics of LCZ696 in patients with HFrEF. This was an open-label, noncontrolled single-sequence study. After a 24-h run-in period, patients (n = 30) with HFrEF (EF ≤ 40%; NYHA class II-IV) received LCZ696 100 mg twice daily (bid) for 7 days and 200 mg bid for 14 days, along with standard treatment for heart failure (HF) (except angiotensin-converting enzyme inhibitors [ACEIs] or angiotensin receptor blockers [ARBs]). On Day 21, significant increases were observed in the plasma biomarkers indicative of neprilysin and RAAS inhibition (ratio-to-baseline: cyclic guanosine monophosphate [cGMP], 1.38; renin concentration and activity, 3.50 and 2.27, respectively; all, P sacubitril (neprilysin inhibitor prodrug), LBQ657 (active neprilysin inhibitor), and valsartan were reached within 0.5, 2.5, and 2 h. Between 100- and 200-mg doses, the Cmax and AUC0-12 h for sacubitril and LBQ657 were approximately dose-proportional while that of valsartan was less than dose-proportional. Treatment with LCZ696 for 21 days was well tolerated and resulted in plasma biomarker changes indicative of neprilysin and RAAS inhibition in patients with HF. The pharmacokinetic exposure of the LCZ696 analytes in patients with HF observed in this study is comparable to that observed in the pivotal Phase III study. © 2016 John Wiley & Sons Ltd.

  11. On improvement in ejection fraction with iron chelation in thalassemia major and the risk of future heart failure

    Directory of Open Access Journals (Sweden)

    Carpenter JP

    2011-09-01

    Full Text Available Abstract Background Trials of iron chelator regimens have increased the treatment options for cardiac siderosis in beta-thalassemia major (TM patients. Treatment effects with improved left ventricular (LV ejection fraction (EF have been observed in patients without overt heart failure, but it is unclear whether these changes are clinically meaningful. Methods This retrospective study of a UK database of TM patients modelled the change in EF between serial scans measured by cardiovascular magnetic resonance (CMR to the relative risk (RR of future development of heart failure over 1 year. Patients were divided into 2 strata by baseline LVEF of 56-62% (below normal for TM and 63-70% (lower half of the normal range for TM. Results A total of 315 patients with 754 CMR scans were analyzed. A 1% absolute increase in EF from baseline was associated with a statistically significant reduction in the risk of future development of heart failure for both the lower EF stratum (EF 56-62%, RR 0.818, p Conclusion These data show that during treatment with iron chelators for cardiac siderosis, small increases in LVEF in TM patients are associated with a significantly reduced risk of the development of heart failure. Thus the iron chelator induced improvements in LVEF of 2.6% to 3.1% that have been observed in randomized controlled trials, are associated with risk reductions of 25.5% to 46.4% for the development of heart failure over 12 months, which is clinically meaningful. In cardiac iron overload, heart mitochondrial dysfunction and its relief by iron chelation may underlie the changes in LV function.

  12. Anti-ejection system for control rod drives

    International Nuclear Information System (INIS)

    Matthews, J.C.

    1977-01-01

    A linearly movable latch mechanism is provided to move into engagement with a deformable collet whenever an undesired ejection of a leadscrew is initiated from a nuclear reactor mounted control rod drive. Such an undesired ejection would occur in the event of a rupture in a housing of the control rod drive. The collet is deformed by the linear movement of the latch mechanism to wedge itself against the leadscrew and prevent the ejection of the leadscrew from the housing. The latch mechanism is made to be controllably engageable with the leadscrew and when thus engaged to allow the leadscrew to move in a control direction while moving with the leadscrew to engage and deform the collet when the leadscrew moves in an ejection direction. 13 claims, 2 figures

  13. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  14. Effects of catheter-based renal denervation on heart failure with reduced ejection fraction: a systematic review and meta-analysis.

    Science.gov (United States)

    Fukuta, Hidekatsu; Goto, Toshihiko; Wakami, Kazuaki; Ohte, Nobuyuki

    2017-11-01

    Despite the recent advances in the management of heart failure, the mortality of heart failure patients remains high. It is of urgent need to develop new therapy for heart failure. Heart failure is characterized by increased sympathetic activity, and chronic sympathetic activation is involved in the maintenance of the pathological state. Catheter-based renal denervation (RDN) has emerged as an invasive but safe approach that can reduce sympathetic activation. Studies have reported inconsistent results regarding the effect of RDN in heart failure patients due to limited power with small sample sizes. We aimed to conduct a meta-analysis of the effect of RDN on heart failure patients with reduced left ventricular (LV) ejection fraction (EF). An electronic search for studies examining the effect of RDN on LV function in heart failure patients with reduced EF was conducted. Two controlled (80 patients) and 2 uncontrolled studies (21 patients) were included in this meta-analysis. In the pooled analysis, 6 months after RDN, there was a greater increase in EF (weighted mean difference [95% CI] = 8.63 [6.02, 11.24] %) and a greater decrease in LV end-diastolic diameter (-0.58 [-0.83, -0.34] cm) in RDN group than in control group. No serious adverse events such as acute renal artery stenosis and dissection occurred. Our meta-analysis of feasibility studies suggests that RDN may improve LV function in heart failure patients with reduced EF, providing the rationale to conduct next phase trials to confirm the observed potential benefits of RDN.

  15. Predictive potential of macrophage migration inhibitory factor (MIF) in patients with heart failure with preserved ejection fraction (HFpEF).

    Science.gov (United States)

    Luedike, Peter; Alatzides, Georgios; Papathanasiou, Maria; Heisler, Martin; Pohl, Julia; Lehmann, Nils; Rassaf, Tienush

    2018-05-04

    Prognostication in heart failure with preserved ejection fraction (HFpEF) is challenging and novel biomarkers are urgently needed. Macrophage migration inhibitory factor (MIF) is a pro-inflammatory cytokine that plays a crucial role in cardiovascular and various inflammatory diseases. Whether MIF is involved in HFpEF is unknown. Sixty-two patients with HFpEF were enrolled and followed up for 180 days. MIF plasma levels as well as natriuretic peptide (NP) levels were assessed. High MIF levels significantly predicted the combined end-point of all-cause death or hospitalization at 180 days in the univariate analysis (HR 2.41, 95% CI 1.12-5.19, p = 0.025) and after adjustment for relevant covariates in a Cox proportional hazard regression model (HR 2.35, 95% CI 1.05-5.27, p = 0.0374). Furthermore, MIF levels above the median were associated with higher pulmonary artery systolic pressure (PASP) as assessed by echocardiography (PASP 31 mmHg vs 48 mmHg in the low- and high-MIF group, respectively, p = 0.017). NPs significantly correlated with MIF in HFpEF patients (BNP p = 0.011; r = 0.32; NT-proBNP p = 0.027; r = 0.28). MIF was associated with clinical outcomes and might be involved in the pathophysiology of pulmonary hypertension in patients with HFpEF. These first data on MIF in HFpEF should stimulate further research to elucidate the role of this cytokine in heart failure. Trial registration NCT03232671.

  16. Is Rest Really Rest? Resting State Functional Connectivity during Rest and Motor Task Paradigms.

    Science.gov (United States)

    Jurkiewicz, Michael T; Crawley, Adrian P; Mikulis, David J

    2018-04-18

    Numerous studies have identified the default mode network (DMN) within the brain of healthy individuals, which has been attributed to the ongoing mental activity of the brain during the wakeful resting-state. While engaged during specific resting-state fMRI paradigms, it remains unclear as to whether traditional block-design simple movement fMRI experiments significantly influence the default mode network or other areas. Using blood-oxygen level dependent (BOLD) fMRI we characterized the pattern of functional connectivity in healthy subjects during a resting-state paradigm and compared this to the same resting-state analysis performed on motor task data residual time courses after regressing out the task paradigm. Using seed-voxel analysis to define the DMN, the executive control network (ECN), and sensorimotor, auditory and visual networks, the resting-state analysis of the residual time courses demonstrated reduced functional connectivity in the motor network and reduced connectivity between the insula and the ECN compared to the standard resting-state datasets. Overall, performance of simple self-directed motor tasks does little to change the resting-state functional connectivity across the brain, especially in non-motor areas. This would suggest that previously acquired fMRI studies incorporating simple block-design motor tasks could be mined retrospectively for assessment of the resting-state connectivity.

  17. Coronal Mass Ejections An Introduction

    CERN Document Server

    Howard, Timothy

    2011-01-01

    In times of growing technological sophistication and of our dependence on electronic technology, we are all affected by space weather. In its most extreme form, space weather can disrupt communications, damage and destroy spacecraft and power stations, and increase radiation exposure to astronauts and airline passengers. Major space weather events, called geomagnetic storms, are large disruptions in the Earth’s magnetic field brought about by the arrival of enormous magnetized plasma clouds from the Sun. Coronal mass ejections (CMEs) contain billions of tons of plasma and hurtle through space at speeds of several million miles per hour. Understanding coronal mass ejections and their impact on the Earth is of great interest to both the scientific and technological communities. This book provides an introduction to coronal mass ejections, including a history of their observation and scientific revelations, instruments and theory behind their detection and measurement, and the status quo of theories describing...

  18. Risk Related to Pre-Diabetes Mellitus and Diabetes Mellitus in Heart Failure With Reduced Ejection Fraction: Insights From Prospective Comparison of ARNI With ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure Trial.

    Science.gov (United States)

    Kristensen, Søren L; Preiss, David; Jhund, Pardeep S; Squire, Iain; Cardoso, José Silva; Merkely, Bela; Martinez, Felipe; Starling, Randall C; Desai, Akshay S; Lefkowitz, Martin P; Rizkala, Adel R; Rouleau, Jean L; Shi, Victor C; Solomon, Scott D; Swedberg, Karl; Zile, Michael R; McMurray, John J V; Packer, Milton

    2016-01-01

    The prevalence of pre-diabetes mellitus and its consequences in patients with heart failure and reduced ejection fraction are not known. We investigated these in the Prospective Comparison of ARNI With ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure (PARADIGM-HF) trial. We examined clinical outcomes in 8399 patients with heart failure and reduced ejection fraction according to history of diabetes mellitus and glycemic status (baseline hemoglobin A1c [HbA1c]: diabetes mellitus], and ≥ 6.5% [≥ 48 mmol/mol; diabetes mellitus]), in Cox regression models adjusted for known predictors of poor outcome. Patients with a history of diabetes mellitus (n = 2907 [35%]) had a higher risk of the primary composite outcome of heart failure hospitalization or cardiovascular mortality compared with those without a history of diabetes mellitus: adjusted hazard ratio, 1.38; 95% confidence interval, 1.25 to 1.52; P diabetes mellitus and 2103 (25%) had pre-diabetes mellitus. The hazard ratio for patients with undiagnosed diabetes mellitus (HbA1c, > 6.5%) and known diabetes mellitus compared with those with HbA1c diabetes mellitus were also at higher risk (hazard ratio, 1.27 [1.10-1.47]; P diabetes mellitus is associated with a higher risk of adverse cardiovascular outcomes (compared with patients with no diabetes mellitus and HbA1c < 6.0%). LCZ696 was beneficial compared with enalapril, irrespective of glycemic status. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01035255. © 2016 The Authors.

  19. Hemodynamic effects of metoprolol and nifedipine in angina pectoris measured by isotope technique

    Energy Technology Data Exchange (ETDEWEB)

    Bostroem, P.A.

    1988-01-01

    In order to evaluate the therapeutic effects of metoprolol, nifedipine, and their combination, 11 patients with secondary angina pectoris and with thallium tomographic findings indicating coronary artery disease were studied before and after these three treatment regimes in a single-blind cross-over study. The therapeutic effect was measured by standardized working test and isotope angiocardiography, which enabled evaluation of left ventricular ejection fraction, stroke volume, and phase analysis of left ventricular contraction. Treatment with metoprolol and combination therapy increased work performance. Ejection fraction did not differentiate the treatment regimes, whereas stroke volume was significantly lower at work and heart rate higher at rest and at work during nifedipine treatment compared to either metoprolol or combination treatment (p less than 0.05). Cardiac output was significantly reduced during nifedipine and metoprolol treatment during work (p less than 0.05). Phase improved after all therapeutic regimes, but reached significance only during the metoprolol treatment period at rest (p less than 0.05).

  20. Cardiac function and central haemodynamics in severe chronic obstructive lung disease. Acute and long-term effects of felodipine

    Energy Technology Data Exchange (ETDEWEB)

    Bratel, T; Hedenstierna, G; Lundquist, H; Nyquist, O; Ripe, E

    1988-01-01

    Eleven patients, with advanced chronic obstructive lung disease (COLD), received an infusion of the calcium antagonist felodipine at a rate of 0.9 mg/h. Pulmonary and systemic vascular resistances (PVR and SVR) at rest were reduced by 18% and 33%, respectively. Cardiac output increased by 33%. The right venticular and left venticular ejection fractions (RVEF and LVEF), measured by equilibrium gated radionuclide ventriculography, Increased by 32% and 25%, respectively. During exercise both PVR and SVR fell by a mean of 30%. RVEF and LVEF both increased by about 14%. After three months of oral felopdipine treatment, a dose-related decrease in PVR was noted at rest (r=-0.83) compared with pretreatment values. There was an increase in RVEF which correlated to a reduction in PVR. Three patiens discontinued the trial due to side effects. It is concluded that the reduction of PVR induced by felodipine is accompanied by an improvement in right heart function as measured by ejection fraction measurements.

  1. Rationale and Design of the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (Reduce LAP-HF) Trial

    DEFF Research Database (Denmark)

    Hasenfuss, Gerd; Gustafsson, Finn; Kaye, David

    2015-01-01

    OBJECTIVE: Heart failure with preserved ejection fraction (HFpEF) is characterized by elevated left atrial pressure during rest and/or exercise. The Reduce LAP-HF (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial will evaluate the safety and performance of the Interatrial...... Shunt Device (IASD) System II, designed to directly reduce elevated left atrial pressure, in patients with HFpEF. METHODS: The Reduce LAP-HF Trial is a prospective, nonrandomized, open-label trial to evaluate a novel device that creates a small permanent shunt at the level of the atria. A minimum of 60...... patients with ejection fraction ≥40% and New York Heart Association functional class III or IV heart failure with a pulmonary capillary wedge pressure (PCWP) ≥15 mm Hg at rest or ≥25 mm Hg during supine bike exercise will be implanted with an IASD System II, and followed for 6 months to assess the primary...

  2. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  3. Influence of Ejection Fraction on Outcomes and Efficacy of Sacubitril/Valsartan (LCZ696) in Heart Failure with Reduced Ejection Fraction: The Prospective Comparison of ARNI with ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure (PARADIGM-HF) Trial.

    Science.gov (United States)

    Solomon, Scott D; Claggett, Brian; Desai, Akshay S; Packer, Milton; Zile, Michael; Swedberg, Karl; Rouleau, Jean L; Shi, Victor C; Starling, Randall C; Kozan, Ömer; Dukat, Andrej; Lefkowitz, Martin P; McMurray, John J V

    2016-03-01

    The angiotensin receptor neprilysin inhibitor sacubitril/valsartan (LCZ696) reduced cardiovascular morbidity and mortality compared with enalapril in patients with heart failure (HF) and reduced ejection fraction (EF) in the Prospective Comparison of ARNI with ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure (PARADIGM-HF) trial. We evaluated the influence of EF on clinical outcomes and on the effectiveness of sacubitril/valsartan compared with enalapril. Eight thousand three hundred ninety-nine patients with New York Heart Association class II to IV HF with reduced EF [left ventricular EF (LVEF) ≤40%] were randomized to sacubitril/valsartan 97/103 mg twice daily versus enalapril 10 mg twice daily and followed for a median of 27 months. The primary study end point was cardiovascular death or HF hospitalization. LVEF was assessed at the sites and recorded on case report forms. We related LVEF to study outcomes and assessed the effectiveness of sacubitril/valsartan across the LVEF spectrum. The mean LVEF in PARADIGM-HF, reported by sites, was 29.5 (interquartile range, 25-34). The risk of all outcomes increased with decreasing LVEF. Each 5-point reduction in LVEF was associated with a 9% increased risk of cardiovascular death or HF hospitalization (hazard ratio, 1.09; 95% confidence interval, 1.05-1.13; PSacubitril/valsartan was effective across the LVEF spectrum, with no evidence of heterogeneity, when modeled either in tertiles (P interaction=0.87) or continuously (P interaction=0.95). In patients with HF and reduced EF enrolled in PARADIGM-HF, LVEF was a significant and independent predictor of all outcomes. Sacubitril/valsartan was effective at reducing cardiovascular death and HF hospitalization throughout the LVEF spectrum. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01035255. © 2016 American Heart Association, Inc.

  4. Evidence linking coronal mass ejections with interplanetary magnetic clouds

    International Nuclear Information System (INIS)

    Wilson, R.M.; Hildner, E.

    1983-12-01

    Using proxy data for the occurrence of those mass ejections from the solar corona which are directed earthward, we investigate the association between the post-1970 interplanetary magnetic clouds of Klein and Burlaga and coronal mass ejections. The evidence linking magnetic clouds following shocks with coronal mass ejections is striking. Six of nine clouds observed at Earth were preceded an appropriate time earlier by meter-wave type II radio bursts indicative of coronal shock waves and coronal mass ejections occurring near central meridian. During the selected periods when no clouds were detected near Earth, the only type II bursts reported were associated with solar activity near the limbs. Where the proxy solar data to be sought are not so clearly suggested, that is, for clouds preceding interaction regions and clouds within cold magnetic enhancements, the evidence linking the clouds and coronal mass ejections is not as clear proxy data usually suggest many candidate mass-ejection events for each cloud. Overall, the data are consistent with and support the hypothesis suggested by Klein and Burlaga that magnetic clouds observed with spacecraft at 1 AU are manifestations of solar coronal mass ejection transients

  5. Cardiac Amyloidosis and its New Clinical Phenotype: Heart Failure with Preserved Ejection Fraction.

    Science.gov (United States)

    Mesquita, Evandro Tinoco; Jorge, Antonio José Lagoeiro; Souza, Celso Vale; Andrade, Thais Ribeiro de

    2017-07-01

    Heart failure with preserved ejection fraction (HFpEF) is now an emerging cardiovascular epidemic, being identified as the main phenotype observed in clinical practice. It is more associated with female gender, advanced age and comorbidities such as hypertension, diabetes, obesity and chronic kidney disease. Amyloidosis is a clinical disorder characterized by the deposition of aggregates of insoluble fibrils originating from proteins that exhibit anomalous folding. Recently, pictures of senile amyloidosis have been described in patients with HFpEF, demonstrating the need for clinical cardiologists to investigate this etiology in suspect cases. The clinical suspicion of amyloidosis should be increased in cases of HFPS where the cardio imaging methods are compatible with infiltrative cardiomyopathy. Advances in cardio imaging methods combined with the possibility of performing genetic tests and identification of the type of amyloid material allow the diagnosis to be made. The management of the diagnosed patients can be done in partnership with centers specialized in the study of amyloidosis, which, together with the new technologies, investigate the possibility of organ or bone marrow transplantation and also the involvement of patients in clinical studies that evaluate the action of the new emerging drugs. Resumo A insuficiência cardíaca com fração de ejeção preservada (ICFEP) é hoje uma epidemia cardiovascular emergente, sendo identificada como o principal fenótipo observado na prática clínica. Está mais associado ao sexo feminino, idade avançada e a comorbidades como hipertensão arterial, diabetes, obesidade e doença renal crônica. A amiloidose é uma desordem clínica caracterizada pelo depósito de agregados de fibrilas insolúveis originadas de proteínas que apresentam dobramento anômalo. Recentemente, têm sido descritos quadros de amiloidose senil em pacientes com ICFEP, demonstrando a necessidade de os cardiologistas clínicos investigarem

  6. Polarized DNA Ejection from the Herpesvirus Capsid

    Science.gov (United States)

    Newcomb, William W.; Cockrell, Shelley K.; Homa, Fred L.; Brown, Jay C.

    2009-01-01

    Ejection of DNA from the capsid is an early step in infection by all herpesviruses. Ejection or DNA uncoating occurs after a parental capsid has entered the host cell cytoplasm, migrated to the nucleus and bound to a nuclear pore. DNA exits the capsid through the portal vertex and proceeds by way of the nuclear pore complex into the nucleoplasm where it is transcribed and replicated. Here we describe use of an in vitro uncoating system to determine which genome end exits first from the herpes simplex virus (HSV-1) capsid. Purified DNA-containing capsids were bound to a solid surface and warmed under conditions in which some, but not all, of the DNA was ejected. Restriction endonuclease digestion was then used to identify the genomic origin of the ejected DNA. The results support the view that the S segment end exits the capsid first. Preferential release at the S end demonstrates that herpesvirus DNA uncoating conforms to the paradigm in dsDNA bacteriophage where the last end packaged is the first to be ejected. Release of HSV-1 DNA beginning at the S end causes the first gene to enter the host cell nucleus to be α4, a transcription factor required for expression of early genes. PMID:19631662

  7. Circulating miR-126 and miR-499 reflect progression of cardiovascular disease; correlations with uric acid and ejection fraction

    Directory of Open Access Journals (Sweden)

    Masoud Khanaghaei

    2016-04-01

    Full Text Available BackgroundThe aim of this study was to assess plasma levels of endothelium- and heart-associated microRNAs (miRNAs miR-126 and miR-499, respectively, using quantitative reverse transcriptase polymerase chain reaction.MethodsA two-step analysis was conducted on 75 patients undergoing off-pomp coronary artery bypass graft (CABG surgery. Five biomarkers of inflammation and cardiac injury were assessed in addition to the above-mentioned miRNAs.ResultsPlasma concentrations of miRNAs were found to be significantly correlated with plasma levels of cardiac troponin I (cTnI (miR-499, r 0.49, p~0.002; miR-126, r = 0.30, p~0.001, indicating cardiac damage. Data analysis revealed that miR-499 had higher sensitivity and specificity for cardiac injury than miR-126, which reflects more endothelial activation. Interestingly, a strong correlation was observed between both miRNAs and uric acid (UA levels with ventricular contractility measured as ejection fraction (EF (miR-499/EF%, r = 0.58, p~0.004; UA/EF%, r = -0.6, p~0.006; UA/miR-499, r = -0.34; UA/miR-126, r = 0.5, p~0.01.ConclusionsIn patients undergoing CABG, circulating miR-126/499 is associated with presentation of traditional risk factors and reflects post-operative response to injury. Plasma pool of miRNAs likely reflects extracellular miRNAs which are proportional to intracellular miRNA levels. Therefore, circulating levels of these miRNAs have prognostic implications in detection of higher risk of future cardiovascular events.

  8. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  9. Coronal Mass Ejections

    CERN Document Server

    Kunow, H; Linker, J. A; Schwenn, R; Steiger, R

    2006-01-01

    It is well known that the Sun gravitationally controls the orbits of planets and minor bodies. Much less known, however, is the domain of plasma fields and charged particles in which the Sun governs a heliosphere out to a distance of about 15 billion kilometers. What forces activates the Sun to maintain this power? Coronal Mass Ejections (CMEs) and their descendants are the troops serving the Sun during high solar activity periods. This volume offers a comprehensive and integrated overview of our present knowledge and understanding of Coronal Mass Ejections (CMEs) and their descendants, Interplanetary CMEs (ICMEs). It results from a series of workshops held between 2000 and 2004. An international team of about sixty experimenters involved e.g. in the SOHO, ULYSSES, VOYAGER, PIONEER, HELIOS, WIND, IMP, and ACE missions, ground observers, and theoreticians worked jointly on interpreting the observations and developing new models for CME initiations, development, and interplanetary propagation. The book provides...

  10. Analysis of high burnup fuel behavior under control rod ejection accident in Korea standard nuclear power plant

    International Nuclear Information System (INIS)

    Lee, Chan Bok; Lee, Chung Chan; Kim, Oh Hwan; Kim, Jong Jin

    1996-07-01

    Test results of high burnup fuel behavior under RIA(reactivity insertion accident) indicated that fuel might fail at the fuel enthalpy lower than that in the current fuel failure criteria was derived by the conservative assumptions and analysis of fuel failure mechanisms, and applied to the analysis of control rod ejection accident in the 1,000 MWe Korea standard PWR. Except that three dimensional core analysis was performed instead of conventional zero dimensional analysis, all the other conservative assumptions were kept. Analysis results showed that less than on percent of the fuel rods in the core has failed which was much less than the conventional fuel failure fraction, 9.8 %, even though a newly derived fuel failure criteria -Fuel failure occurs at the power level lower than that in the current fuel failure criteria. - was applied, since transient fuel rod power level was significantly decreased by analyzing the transient fuel rod power level was significantly decreased by analyzing the transient core three dimensionally. Therefore, it can be said that results of the radiological consequence analysis for the control rod ejection accident in the FSAR where fuel failure fraction was assumed 9.8 % is still bounding. 18 tabs., 48 figs., 39 refs. (Author)

  11. Continuous on-line monitoring of left ventricular function with a new nonimaging detector:validation and clinical use in the evaluation of patients post angioplasty.

    Science.gov (United States)

    Breisblatt, W M; Schulman, D S; Follansbee, W P

    1991-06-01

    A new miniaturized nonimaging radionuclide detector (Cardioscint, Oxford, England) was evaluated for the continuous on-line assessment of left ventricular function. This cesium iodide probe can be placed on the patient's chest and can be interfaced to an IBM compatible personal computer conveniently placed at the patient's bedside. This system can provide a beat-to-beat or gated determination of left ventricular ejection fraction and ST segment analysis. In 28 patients this miniaturized probe was correlated against a high resolution gamma camera study. Over a wide range of ejection fraction (31% to 76%) in patients with and without regional wall motion abnormalities, the correlation between the Cardioscint detector and the gamma camera was excellent (r = 0.94, SEE +/- 2.1). This detector system has high temporal (10 msec) resolution, and comparison of peak filling rate (PFR) and time to peak filling (TPFR) also showed close agreement with the gamma camera (PFR, r = 0.94, SEE +/- 0.17; TPFR, r = 0.92, SEE +/- 6.8). In 18 patients on bed rest the long-term stability of this system for measuring ejection fraction and ST segments was verified. During the monitoring period (108 +/- 28 minutes) only minor changes in ejection fraction occurred (coefficient of variation 0.035 +/- 0.016) and ST segment analysis showed no significant change from baseline. To determine whether continuous on-line measurement of ejection fraction would be useful after coronary angioplasty, 12 patients who had undergone a successful procedure were evaluated for 280 +/- 35 minutes with the Cardioscint system.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. THE ROLE OF FACTORS AFFECTING THE FORMATION OF CHRONIC HEART FAILURE WITH PRESERVED EJECTION FRACTION

    Directory of Open Access Journals (Sweden)

    M. V. Kurkina

    2017-01-01

    Full Text Available Aim. To study the combination and contribution of risk factors (age, hypertension (HT, obesity, diabetes mellitus, chronic kidney disease (CKD, length of illness leading to the formation of chronic heart failure (CHF with preserved ejection fraction (EF.Material and methods. The study included 100 hypertensive patients (aged 40 to 80 years with concomitant obesity or diabetes or CKD. Patients were divided into 4 groups depending on the presence of one major and/or several concomitant diseases. Echocardiography, assessment of large arterial vessels stiffness indices (SI m/s, CAVI m/s, and determination of small muscle arteries tonus (RI% were performed in all patients.Results. Remodeling of the left ventricle (LV and left atrial (LA was observed in all patients with comorbid status, as well as reduction in diastolic function. The LV myocardial mass index in the first group was 117.2±31.4 g/m2, in the second one – 125.9±27.4 g/m2, in the third group – 121.5±15.6 g/m2 and in the fourth one – 126.1±11.5 g/m2. A significant increase in the LA volume index was founded in the first group  – 33.4±3.9 ml/m2, in the second one – 39.6±9.1 ml/m2, in the third group – 38.1±5.2 ml/m2 and in the fourth one – 39.8±6.6 ml/m2 (р<0.05. The parameters reflecting the rigidity of large arterial vessels (SI m/s, CAVI m/s also exceeded the threshold values in each group; significant differences SI were between the first and fourth, second  and fourth groups  (р<0.05, CAVI between the first and third groups  (р<0.05. A significant correlation was found between CAVI and age (r=0.63, which indicated an increase in arterial stiffness with age.Conclusions. In the formation of CHF with preserved EF, additional factors enhance the changes associated with LV remodeling and LA overload. These changes occur with a progressive decrease in LV diastolic function and increase in myocardial stiffness. HT and obesity are the main contributors to the

  13. Coronal mass ejections and coronal structures

    International Nuclear Information System (INIS)

    Hildner, E.; Bassi, J.; Bougeret, J.L.

    1986-01-01

    Research on coronal mass ejections (CMF) took a variety of forms, both observational and theoretical. On the observational side there were: case studies of individual events, in which it was attempted to provide the most complete descriptions possible, using correlative observations in diverse wavelengths; statistical studies of the properties of CMEs and their associated activity; observations which may tell us about the initiation of mass ejections; interplanetary observations of associated shocks and energetic particles; observations of CMEs traversing interplanetary space; and the beautiful synoptic charts which show to what degree mass ejections affect the background corona and how rapidly (if at all) the corona recovers its pre-disturbance form. These efforts are described in capsule form with an emphasis on presenting pictures, graphs, and tables so that the reader can form a personal appreciation of the work and its results

  14. Analysis Of Control Rod Ejection Of APR1400 By RELAP5

    International Nuclear Information System (INIS)

    Le Thi Thu; Hoang Minh Giang; Vo Thi Huong; Le Dai Dien

    2011-01-01

    This paper presents the analysis of Reactivity Induced Accident caused by ejection of a Control Element Assembly (CEA) from APR 1400 reactor vessel within 0.05 second. The initial condition were assumed as following: power level at 102%, delayed neutron fraction β = 412 pcm and CEA worth = 110 pcm. The analysis was simulated by RELAP5 code through two step: calculation of steady state and calculation of transient with initial condition mentioned as above. Some output results were presented with explanation: sequence of events corresponding to the time of the accident, the system behavior as power, reactivity feedback from fuel temperature changes (Doppler) as well as temperature, pressure, DNBR within 6 second of the accident. (author)

  15. Computer analysis of the exercise electrocardiogram and control of radionuclide ventriculography: an optimal statistical decision model for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Hsia, P.W.E.

    1987-01-01

    A new automated technique for the diagnosis of coronary artery disease (CAD) by stress electrocardiography and radionuclide ventriculography (RNV) has been developed. The method employs digital signal processing of the electrocardiogram (ECG) for recognition of ischemic and arrhythmic events. On-line detection of abnormal beats is used for control image acquisition by the gamma camera resulting in improved image quality since only identical beats are included in the composite images of the cardiac cycle. A combined stress ECG analysis which measures ST changes indicative of ischemia, and radionuclide results, which reveal corresponding ejection fraction abnormalities yields greater sensitivity and specificity than either test alone. Digitized data from the electrocardiogram are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is given. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate are completely automated. A statistical model base on computerized ST segment measurements combined with radionuclide ventriculography data has been developed by using a logistic model with stepwise regression fitting. A previously acquired database of similar measurements was used for designing the model. The most significant parameters were found to be (1) ejection fraction of exercise RNV; (2) difference of ST level between exercise and resting test (stdif); and (3) ejection fraction difference between exercise and resting test. The new parameter stdif, not previously used in ECG interpretation, was found to be of great diagnostic significance

  16. Comparative Assessment of the Preventive Use of Intra-Aortic Baloon Counterpulsation and Levosimendan in Patients with Coronary Heart Disease and Low Left Ventricular Ejection Fraction

    Directory of Open Access Journals (Sweden)

    V. A. Boboshko

    2012-01-01

    Full Text Available The aim of our study was to compare the efficiency of the use of intraaortic balloon counterpulsation (IABP and levosi-mendan in patients with low left ventricular ejection fraction operated on under cardiopulmonary bypass. The study included 90 patients who were randomized into three groups according to the strategy of hemodynamic support. Group A patients received IABP 24 hours before surgery. In group B, preventive IABP was combined with intraoperative levosimendan infusion. Group C patients received intraoperative levosimendan infusion only. Hemodynamics, the markers of myocardial damage and heart failure, postoperative complications and length of hospital stay were observed. The patients treated with lev-osimendan had a more stable hemodynamic profile. Troponin I level was significantly lower in Group C six hours after cardiopulmonary bypass than that in group A. Length of stay in intensive care was significantly lower in Group C. The pre-operative concentration of BNP (>360 pg/ml is a predictor of inotropic support in the postoperative period. The results of our study indicate that the use of levosimendan in high-risk patients is effective and shows the results comparable with those of intra-aortic balloon counterpulsation.

  17. Ivabradine, a novel heart rate slower: is it a sword of double blades in patients with idiopathic dilated cardiomyopathy?

    Science.gov (United States)

    Rayan, Mona; Tawfik, Mazen; Alabd, Ali; Gamal, Amr

    2011-08-01

    To prospectively assess the safety and efficacy of ivabradine in patients with idiopathic dilated cardiomyopathy. We included 35 patients with idiopathic dilated cardiomyopathy with an ejection fraction (EF) 70 beats/min despite optimal medical therapy, according to the international guidelines in this prospective, non-randomized, single-arm, open-label safety study. Ivabradine was used as an add-on therapy to the maximally tolerated b-blocker in an increasing titrated dose till a target dose of 15 mg/day or resting heart rate of 60 beats/min for 3 months. During follow-up period the safety, patient tolerance and efficacy of this drug were assessed. All patients underwent 12-lead resting electrocardiography and Holter monitoring at inclusion and after 3 months. Statistical analysis was accomplished using paired t-test and Pearson correlation analysis. We found a significant reduction in the resting heart rate by a mean of 25.9 ± 9.4%, without a significant change of blood pressure. There was no prolongation of PR, QTc or QRS durations. Ventricular ectopic activity showed significant reduction (p<0.001). There was a significant correlation between the resting heart rate, NYHA and left ventricular ejection fraction (p<0.001 for both). One patient developed photopsia and decompensation was observed in another patient. Ivabradine is a safe and effective drug in reducing resting heart rate, improving NYHA functional class without undesirable effects on conduction parameters or ectopic activity.

  18. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

    International Nuclear Information System (INIS)

    Navare, Sachin M.; Liu, Yi-Hwa; Wackers, Frans J.T.

    2003-01-01

    Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET. (orig.)

  19. A Global Assessment of Circulating Prolysyl Oxidase in Nonischemic Patients With Garden-variety Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Muñoz Calvo, Benjamín; Villa Martínez, Ana; López Orgil, Susana; López Andrés, Natalia; Román García, Feliciano; Víctor Palomares, Virginia; de la Calle de la Villa, Esther; Nadador Patiño, Verónica; Arribas-Gómez, Ignacio

    2018-05-25

    Lysyl oxidase is overexpressed in the myocardium of patients with hypertensive cardiomyopathy. We aimed to explore whether patients with hypertensive-metabolic heart failure with preserved ejection fraction (HM-HFpEF) also have increased concentrations of circulating prolysyl oxidase (cpLOX) and its possible consequences. We quantified cpLOX concentrations in 85 nonischemic patients with stage C, HM-HFpEF, and compared them with those of 51 healthy controls. We also assessed the correlations of cpLOX with myocardial stiffness parameters, collagen turnover products and fibrogenic cytokines, as well as the predictive value of plasma proenzyme levels at 1-year of follow-up. We detected raised cpLOX values and found that they correlated with calculated E/E' ratios and stiffness constants. The subgroup of patients with type I diastolic dysfunction showed a single negative correlation between cpLOX and B-type natriuretic peptide whereas patients with a restrictive diastolic pattern showed a strong correlation between cpLOX and galectin-3. Kaplan-Meier analysis revealed that cpLOX > 52.20 ng/mL slightly increased the risk of a fatal outcome (log-rank = 4.45; P = .034). When Cox regression was used, cpLOX was found to be a significant independent predictor of cardiovascular death or hospitalization due to the decompensation of HM-HFpEF (HR, 1.360; 95%CI, 1.126-1.638; P = .046). Patients with symptomatic HM-HFpEF show high cpLOX serum levels associated with restrictive diastolic filling indices. These levels represent a moderate risk factor for poor clinical outcome. Throughout the natural history of HM-HFpEF, we observed that cpLOX concentrations were initially negatively correlated with B-type natriuretic peptide but positively correlated with galectin-3 as advanced diastolic dysfunction developed. Copyright © 2018. Published by Elsevier España, S.L.U.

  20. Spironolactone use and higher hospital readmission for Medicare beneficiaries with heart failure, left ventricular ejection fraction 73 m(2.).

    Science.gov (United States)

    Inampudi, Chakradhari; Parvataneni, Sridivya; Morgan, Charity J; Deedwania, Prakash; Fonarow, Gregg C; Sanders, Paul W; Prabhu, Sumanth D; Butler, Javed; Forman, Daniel E; Aronow, Wilbert S; Allman, Richard M; Ahmed, Ali

    2014-07-01

    Although randomized controlled trials have demonstrated benefits of aldosterone antagonists for patients with heart failure and reduced ejection fraction (HFrEF), they excluded patients with serum creatinine >2.5 mg/dl, and their use is contraindicated in those with advanced chronic kidney disease (CKD). In the present analysis, we examined the association of spironolactone use with readmission in hospitalized Medicare beneficiaries with HFrEF and advanced CKD. Of the 1,140 patients with HFrEF (EF 73 m(2)), 207 received discharge prescriptions for spironolactone. Using propensity scores (PSs) for the receipt of discharge prescriptions for spironolactone, we estimated PS-adjusted hazard ratios (HRs) and 95% confidence intervals (CIs) for spironolactone-associated outcomes. Patients (mean age 76 years, 49% women, 25% African-American) had mean EF 28%, mean eGFR 31 ml/min/1.73 m(2), and mean potassium 4.5 mEq/L. Spironolactone use had significant PS-adjusted association with higher risk of 30-day (HR 1.41, 95% CI 1.04 to 1.90) and 1-year (HR 1.36, 95% CI 1.13 to 1.63) all-cause readmissions. The risk of 1-year all-cause readmission was higher among 106 patients with eGFR 73 m(2) (HR 4.75, 95% CI 1.84 to 12.28) than among those with eGFR 15 to 45 ml/min/1.73 m(2) (HR 1.34, 95% CI 1.11 to 1.61, p for interaction 0.003). Spironolactone use had no association with HF readmission and all-cause mortality. In conclusion, among hospitalized patients with HFrEF and advanced CKD, spironolactone use was associated with higher all-cause readmission but had no association with all-cause mortality or HF readmission. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. B-lines with Lung Ultrasound: The Optimal Scan Technique at Rest and During Stress.

    Science.gov (United States)

    Scali, Maria Chiara; Zagatina, Angela; Simova, Iana; Zhuravskaya, Nadezhda; Ciampi, Quirino; Paterni, Marco; Marzilli, Mario; Carpeggiani, Clara; Picano, Eugenio

    2017-11-01

    Various lung ultrasound (LUS) scanning modalities have been proposed for the detection of B-lines, also referred to as ultrasound lung comets, which are an important indication of extravascular lung water at rest and after exercise stress echo (ESE). The aim of our study was to assess the lung water spatial distribution (comet map) at rest and after ESE. We performed LUS at rest and immediately after semi-supine ESE in 135 patients (45 women, 90 men; age 62 ± 12 y, resting left ventricular ejection fraction = 41 ± 13%) with known or suspected heart failure or coronary artery disease. B-lines were measured by scanning 28 intercostal spaces (ISs) on the antero-lateral chest, 2nd-5th IS, along with the midaxillary (MA), anterior axillary (AA), mid-clavicular (MC) and parasternal (PS) lines. Complete 28-region, 16-region (3rd and 4th IS), 8-region (3rd IS), 4-region (3rd IS, only AA and MA) and 1-region (left 3rd IS, MA) scans were analyzed. In each space, the B-lines were counted from 0 = black lung to 10 = white lung. Interpretable images were obtained in all spaces (feasibility = 100 %). B-lines (>0 in at least 1 space) were present at ESE in 93 patients (69%) and absent in 42. More B-lines were found in the 3rd IS and along AA and MA lines. The B-line cumulative distribution was symmetric at rest (right/left = 1.10) and asymmetric with left lung predominance during stress (right/left = 0.67). The correlation of per-patient B-line number between 28-S and 16-S (R 2  = 0.9478), 8-S (R 2  = 0.9478) and 4-S scan (R 2  = 0.9146) was excellent, but only good with 1-S (R 2  = 0.8101). The average imaging and online analysis time were 5 s per space. In conclusion, during ESE, the comet map of lung water accumulation follows a predictable spatial pattern with wet spots preferentially aligned with the third IS and along the AA and MA lines. The time-saving 4-region scan is especially convenient during stress, simply dismissing dry regions and

  2. Do centrioles generate a polar ejection force?

    Science.gov (United States)

    Wells, Jonathan

    2005-01-01

    A microtubule-dependent polar ejection force that pushes chromosomes away from spindle poles during prometaphase is observed in animal cells but not in the cells of higher plants. Elongating microtubules and kinesin-like motor molecules have been proposed as possible causes, but neither accounts for all the data. In the hypothesis proposed here a polar ejection force is generated by centrioles, which are found in animals but not in higher plants. Centrioles consist of nine microtubule triplets arranged like the blades of a tiny turbine. Instead of viewing centrioles through the spectacles of molecular reductionism and neo-Darwinism, this hypothesis assumes that they are holistically designed to be turbines. Orthogonally oriented centriolar turbines could generate oscillations in spindle microtubules that resemble the motion produced by a laboratory vortexer. The result would be a microtubule-mediated ejection force tending to move chromosomes away from the spindle axis and the poles. A rise in intracellular calcium at the onset of anaphase could regulate the polar ejection force by shutting down the centriolar turbines, but defective regulation could result in an excessive force that contributes to the chromosomal instability characteristic of most cancer cells.

  3. Magnetohydrodynamic simulations of the ejection of a magnetic flux rope

    Science.gov (United States)

    Pagano, P.; Mackay, D. H.; Poedts, S.

    2013-06-01

    Context. Coronal mass ejections (CME's) are one of the most violent phenomena found on the Sun. One model to explain their occurrence is the flux rope ejection model. In this model, magnetic flux ropes form slowly over time periods of days to weeks. They then lose equilibrium and are ejected from the solar corona over a few hours. The contrasting time scales of formation and ejection pose a serious problem for numerical simulations. Aims: We simulate the whole life span of a flux rope from slow formation to rapid ejection and investigate whether magnetic flux ropes formed from a continuous magnetic field distribution, during a quasi-static evolution, can erupt to produce a CME. Methods: To model the full life span of magnetic flux ropes we couple two models. The global non-linear force-free field (GNLFFF) evolution model is used to follow the quasi-static formation of a flux rope. The MHD code ARMVAC is used to simulate the production of a CME through the loss of equilibrium and ejection of this flux rope. Results: We show that the two distinct models may be successfully coupled and that the flux rope is ejected out of our simulation box, where the outer boundary is placed at 2.5 R⊙. The plasma expelled during the flux rope ejection travels outward at a speed of 100 km s-1, which is consistent with the observed speed of CMEs in the low corona. Conclusions: Our work shows that flux ropes formed in the GNLFFF can lead to the ejection of a mass loaded magnetic flux rope in full MHD simulations. Coupling the two distinct models opens up a new avenue of research to investigate phenomena where different phases of their evolution occur on drastically different time scales. Movies are available in electronic form at http://www.aanda.org

  4. Assessment of ejection fraction of the right and left ventricles in patients with acute myocardial infarction by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zhang, Youyi; Imai, Kamon; Araki, Yasushi; Nishino, Yukari; Saito, Satoshi; Ozawa, Yukio; Yasugi, Tadao

    1993-01-01

    Right and left ventricular function in acute myocardial infarction (AMI) was assessed by ECG-gated magnetic resonance imaging (MRI) in 64 patients and 8 volunteers. Five short axis images for intrinsic cardiac long-axis of the left ventricle were obtained at 9 msec and 309 msec after the R wave as end-diastole and end-systole. Right and left ventricular volumes were measured by Simpson's rule. The intraobserver variabilities in right and left ventricular ejection fraction (RVEF: r=0.94, LVEF: 0.89) were excellent. The interobserver variabilities in RVEF (r=0.61) and LVEF (r=0.77) were fair. LVEF, but not RVEF, was significantly reduced in patients with AMI. Among left ventricular dysfunction (LVEF≤40%) patients, 50% exhibited right ventricular dysfunction (RVEF≤40%). Among patients without left ventricular dysfunction, only 12% exhibited right ventricular dysfunction. In left ventricular and biventricular dysfunction compared with control, the left ventricular end-diastolic volume index increased (65±10 ml/m 2 , 68±12 ml/m 2 vs 54±8 ml/m 2 ), the end-systolic volume index increased (40±16 ml/m 2 , 43±7 ml/m 2 vs 18±1 ml/m 2 ), and the right ventricular end-diastolic volume index decreased (52±13 ml/m 2 , 53±20 ml/m 2 vs 65±8 ml/m 2 ). MRI can thus be used to assess ventricular systolic function. Since patients with left ventricular dysfunction revealed a high incidence of right ventricular dysfunction, an interaction between the left and right ventricles may occur in ventricular dysfunction. (author)

  5. Predicting changes in flow category in patients with severe aortic stenosis and preserved left ventricular ejection fraction on medical therapy.

    Science.gov (United States)

    Ngiam, Jinghao Nicholas; Kuntjoro, Ivandito; Tan, Benjamin Y Q; Sim, Hui-Wen; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong

    2017-11-01

    Controversy surrounds the prognosis and management of patients with paradoxical low-flow severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF). It was not certain if patients in a particular flow category remained in the same category as disease progressed. We investigated whether there were switches in categories and if so, their predictors. Consecutive subjects (n = 203) with isolated severe AS and paired echocardiography (>180 days apart) were studied. They were divided into 4 groups, based on their flow categories and if they progressed on subsequent echocardiography to switch or remain in the same flow category. Univariate analyses of clinical and echocardiographic parameters identified predictors of these changes in flow category. One hundred eighteen were normal flow (SVI ≥ 35 mL/m 2 ), while 85 were low flow on index echocardiography. In the patients with normal flow, 33% switched to low flow. This was associated with higher valvuloarterial impedance (Zva, P 4.77 mm Hg/mL/m 2 , AUC = 0.81 [95% CI:0.75-0.87, P < .001]). In patients with low flow, 25% switched to normal flow, which was associated with lower Zva and higher SAC and the switch was predicted by a higher initial mean transaortic pressure gradient. A significant number of patients switched flow categories in severe AS with preserved LVEF on subsequent echocardiography. Changes in flow were reflected by respective changes in Zva and SAC. Identifying echocardiographic predictors of a switch in category may guide prognostication and management of such patients. © 2017, Wiley Periodicals, Inc.

  6. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    International Nuclear Information System (INIS)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa

    1997-01-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  7. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa [Osaka Univ. (Japan). Faculty of Medicine] [and others

    1997-08-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF`s derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  8. Fractional Klein-Gordon equation composed of Jumarie fractional derivative and its interpretation by a smoothness parameter

    Science.gov (United States)

    Ghosh, Uttam; Banerjee, Joydip; Sarkar, Susmita; Das, Shantanu

    2018-06-01

    Klein-Gordon equation is one of the basic steps towards relativistic quantum mechanics. In this paper, we have formulated fractional Klein-Gordon equation via Jumarie fractional derivative and found two types of solutions. Zero-mass solution satisfies photon criteria and non-zero mass satisfies general theory of relativity. Further, we have developed rest mass condition which leads us to the concept of hidden wave. Classical Klein-Gordon equation fails to explain a chargeless system as well as a single-particle system. Using the fractional Klein-Gordon equation, we can overcome the problem. The fractional Klein-Gordon equation also leads to the smoothness parameter which is the measurement of the bumpiness of space. Here, by using this smoothness parameter, we have defined and interpreted the various cases.

  9. Reduced variability of visual left ventricular ejection fraction assessment with reference images: The Japanese Association of Young Echocardiography Fellows multicenter study.

    Science.gov (United States)

    Kusunose, Kenya; Shibayama, Kentaro; Iwano, Hiroyuki; Izumo, Masaki; Kagiyama, Nobuyuki; Kurosawa, Koji; Mihara, Hirotsugu; Oe, Hiroki; Onishi, Tetsuari; Onishi, Toshinari; Ota, Mitsuhiko; Sasaki, Shunsuke; Shiina, Yumi; Tsuruta, Hikaru; Tanaka, Hidekazu

    2018-07-01

    Visual estimation of left ventricular ejection fraction (LVEF) is widely applied to confirm quantitative EF. However, visual assessment is subjective, and variability may be influenced by observer experience. We hypothesized that a learning session might reduce the misclassification rate. Protocol 1: Visual LVEFs for 30 cases were measured by 79 readers from 13 cardiovascular tertiary care centers. Readers were divided into 3 groups by their experience: limited (1-5 years, n=28), intermediate (6-11 years, n=26), and highly experienced (12-years, n=25). Protocol 2: All readers were randomized to assess the effect of a learning session with reference images only or feedback plus reference images. After the session, 20 new cases were shown to all readers following the same methodology. To assess the concordance and accuracy pre- and post-intervention, each visual LVEF measurement was compared to overall average values as a reference. Experience affected the concordance in visual EF values among the readers. Groups with intermediate and high experience showed significantly better mean difference (MD), standard deviation (SD), and coefficient of variation (CV) than those with limited experience at baseline. The learning session with reference image reduced the MD, SD, and CV in readers with limited experience. The learning session with reference images plus feedback also reduced proportional bias. Importantly, the misclassification rate for mid-range EF cases was reduced regardless of experience. This large multicenter study suggested that a simple learning session with reference images can successfully reduce the misclassification rate for LVEF assessment. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  10. The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Ali Eshraghi

    2016-03-01

    Full Text Available Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR imaging. Materials and Methods: This observational study was done in Ghaem general hospital in 2014.  LVEF and RVEF were measured in a series of 33 patients with ischemic heart disease, undergoing CMR for the evaluation of myocardial viability. The correlation between RVEF and LVEF in patients with ischemic heart disease was studied, using Pearson product-moment correlation coefficient analysis.   This study was done in Ghaem general hospital in 2014 with simple sapling. Results: Right ventricular end diastolic volume (186.33±58.90 and left ventricular end diastolic volume (121.72±61.64 were significantly correlated (r=0.223, P=0.005. Moreover, there was a significant correlation between right ventricular end systolic volume (88.18±40.90 and left ventricular end systolic volume (140.96±35.33 (r=0.329, P=0.000. The most significant association was observed between RVEF and LVEF (r=0.913, P=0.000. Conclusion: Based on the findings, RVEF and LVEF were significantly correlated in patients with ischemic heart disease, although this association was not always present in all cardiac patients. The cause of this discrepancy is still unknown.

  11. Hydrodynamic ejection of bipolar flows from objects undergoing disk accretion: T Tauri stars, massive pre-main-sequence objects, and cataclysmic variables

    International Nuclear Information System (INIS)

    Torbett, M.V.

    1984-01-01

    A general mechanism is presented for generating pressure-driven winds that are intrinsically bipolar from objects undergoing disk accretion. The energy librated in a boundary layer shock as the disk matter impacts the central object is shown to be sufficient to eject a fraction βapprox.10 -2 to 10 -3 of the accreted mass. These winds are driven by a mechanism that accelerates the flow perpendicular to the plane of the disk and can therefore account for the bipolar geometry of the mass loss observed near young stars. The mass loss contained in these winds is comparable to that inferred for young stars. Thus, disk accretion-driven winds may constitute the T Tauri phase of stellar evolution. This mechanism is generally applicable, and thus massive pre-main-sequence objects as well as cataclysmic variables at times of enhanced accretion are predicted to eject bipolar outflows as well. Unmagnetized accreting neutron stas are also expected to eject bipolar flows. Since this mechanism requires stellar surfaces, however, it will not operate in disk accretion onto black holes

  12. Effects of organic and inorganic nitrate on aortic and carotid haemodynamics in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Chirinos, Julio A; Londono-Hoyos, Francisco; Zamani, Payman; Beraun, Melissa; Haines, Philip; Vasim, Izzah; Varakantam, Swapna; Phan, Timothy S; Cappola, Thomas P; Margulies, Kenneth B; Townsend, Raymond R; Segers, Patrick

    2017-11-01

    To assess the haemodynamic effects of organic vs. inorganic nitrate administration among patients with heart failure with preserved ejection fraction (HFpEF). We assessed carotid and aortic pressure-flow relations non-invasively before and after the administration of 0.4 mg of sublingual nitroglycerin (n = 26), and in a separate sub-study, in response to 12.9 mmoL of inorganic nitrate (n = 16). Nitroglycerin did not consistently reduce wave reflections arriving at the proximal aorta (change in real part of reflection coefficient, 1st harmonic: -0.09; P = 0.01; 2nd harmonic: -0.045, P = 0.16; 3rd harmonic: +0.087; P = 0.05), but produced profound vasodilatation in the carotid territory, with a significant reduction in systolic blood pressure (133.6 vs. 120.5 mmHg; P = 0.011) and a marked reduction in carotid bed vascular resistance (19 580 vs. 13 078 dynes · s/cm 5 ; P = 0.001) and carotid characteristic impedance (3440 vs. 1923 dynes · s/cm 5 ; P = 0.002). Inorganic nitrate, in contrast, consistently reduced wave reflections across the first three harmonics (change in real part of reflection coefficient, 1st harmonic: -0.12; P = 0.03; 2nd harmonic: -0.11, P = 0.01; 3rd harmonic: -0.087; P = 0.09) and did not reduce blood pressure, carotid bed vascular resistance, or carotid characteristic impedance (P = NS). Nitroglycerin produces marked vasodilatation in the carotid circulation, with a pronounced reduction in blood pressure and inconsistent effects on central wave reflections. Inorganic nitrate, in contrast, produces consistent reductions in wave reflections, and unlike nitroglycerin, it does so without significant hypotension or cerebrovascular dilatation. These haemodynamic differences may underlie the different effects on exercise capacity and side effect profile of inorganic vs. organic nitrate in HFpEF. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.

  13. Diagnosis of heart failure with preserved ejection fraction: improved accuracy with the use of markers of collagen turnover.

    LENUS (Irish Health Repository)

    Martos, Ramon

    2012-02-01

    AIMS: Heart failure with preserved ejection fraction (HF-PEF) can be difficult to diagnose in clinical practice. Myocardial fibrosis is a major determinant of diastolic dysfunction (DD), potentially contributing to the progression of HF-PEF. The aim of this study was to analyse whether serological markers of collagen turnover may predict HF-PEF and DD. METHODS AND RESULTS: We included 85 Caucasian treated hypertensive patients (DD n=65; both DD and HF-PEF n=32). Serum carboxy (PICP), amino (PINP), and carboxytelo (CITP) peptides of procollagen type I, amino (PIIINP) peptide of procollagen type III, matrix metalloproteinases (MMP-1, MMP-2, and MMP-9), and tissue inhibitor of MMP levels were assayed. Using receiver operating characteristic curve analysis, MMP-2 (AUC=0.91; 95% CI: 0.84, 0.98), CITP (0.83; 0.72, 0.92), PICP (0.82; 0.72, 0.92), B-type natriuretic peptide (BNP) (0.82; 0.73, 0.91), MMP-9 (0.79; 0.68, 0.89), and PIIINP (0.78; 0.66, 0.89) levels were significant predictors of HF-PEF (P<0.01 for all). Carboxytelo peptides of procollagen type I (AUC=0.74; 95% CI: 0.62, 0.86), MMP-2 (0.73; 0.62, 0.84), PIIINP (0.73; 0.60, 0.85), BNP (0.69; 0.55, 0.83) and PICP (0.66; 0.54, 0.78) levels were significant predictors of DD (P<0.05 for all). A cutoff of 1585 ng\\/mL for MMP-2 provided 91% sensitivity and 76% specificity for predicting HF-PEF and combinations of biomarkers could be used to adjust either sensitivity or specificity. CONCLUSION: Markers of collagen turnover identify patients with HF-PEF and DD. Matrix metalloproteinase 2 may be more useful than BNP in the identification of HF-PEF. This suggests that these new biochemical tools may assist in identifying patients with these diagnostically challenging conditions.

  14. β-Blockers on Discharge From Acute Atrial Fibrillation Are Associated With Decreased Mortality and Lower Cerebrovascular Accidents in Patients With Heart Failure and Reduced Ejection Fraction.

    Science.gov (United States)

    Abi Khalil, Charbel; Zubaid, Mohammad; Asaad, Nidal; Rashed, Wafa A; Hamad, Adel Khalifa; Singh, Rajvir; Al Suwaidi, Jassim

    2018-04-01

    The benefits of β-blockers in patients with heart failure (HF) with reduced ejection fraction (HFrEF) and atrial fibrillation (AF) are controversial. The Gulf Survey of Atrial Fibrillation Events was a prospective, multinational, observational registry of consecutive patients with AF recruited from the emergency department (ED). We studied the incidence of 6- and 12-month mortality, hospitalization for HF or AF, and stroke/transient ischemic attacks (TIAs) in patients with HFrEF, in relation to β-blockers on discharge from the ED or the subsequent hospital stay. Of the 344 patients with HFrEF and AF in the GULF-SAFE, 177 patients (53%) were discharged on β-blockers. Mortality was lower in those patients compared with the non-β-blockers group at 6 and 12 months (odds ratios [ORs] 0.31, 95% CI [0.16-0.61]; OR 0.30, 95% CI [0.16-0.55]; P = .001 for both, respectively), so was the risk of stroke/TIAs. However, hospitalizations for AF increased in the β-blockers group. Even after adjustment for several risk variables in 2 different models, the beneficial effect of β-blockers on mortality persisted, at the cost of more hospitalization for AF.

  15. Impact of a systolic parameter, defined as the ratio of right brachial pre-ejection period to ejection time, on the relationship between brachial-ankle pulse wave velocity and left ventricular diastolic function.

    Science.gov (United States)

    Hsu, Po-Chao; Lin, Tsung-Hsien; Lee, Chee-Siong; Chu, Chun-Yuan; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2011-04-01

    Arterial stiffness is correlated with left ventricular (LV) diastolic function as well as susceptibility to LV systolic function. Therefore, if LV systolic function is not known, the relationship between arterial stiffness and LV diastolic function is difficult to determine. A total of 260 patients were included in the study. The brachial-ankle pulse wave velocity (baPWV) and the ratio of right brachial pre-ejection period to ejection time (rbPEP/rbET) were measured using an ABI-form device. Patients were classified into four groups. Groups 1, 2, 3 and 4 were patients with rbPEP/rbET and baPWV below the median, rbPEP/rbET above but baPWV below the median, rbPET/rbET below but baPWV above the median, and rbPET/rbET and baPWV above the median, respectively. The LV ejection fractions in groups 1 and 3 were higher than those in groups 2 and 4 (Pwave velocity to Ea that were comparable to those in groups 3 and 4. In conclusion, rbPEP/rbET had an impact on the relationship between baPWV and LV diastolic function. In patients with high rbPEP/rbET but low baPWV, low baPWV may not indicate good LV diastolic function but implies that cardiac dysfunction may precede vascular dysfunction in such patients. When interpreting the relationship between baPWV and LV diastolic function, the rbPEP/rbET value obtained from the same examination should be considered.

  16. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  17. Evaluation of the Efficiency of Alveolar Opening in Cardiosurgical Patients with Low Left Ventricular Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Yu. G Zorina

    2009-01-01

    Full Text Available Objective: to determine the optimum alveolar opening parameters for the improvement of postoperative pulmonary oxygenizing function in patients with a left ventricular ejection fraction (LVEF of less or more than 40% after aortocoronary bypass surgery (ACBS. Subjects and methods. Twenty patients with a LVEF of less than 40% after ACBS and with postoperative pulmonary oxygenizing dysfunction (PaO2/FiO2 less than 250 (Group 1 were examined. A control group consisted of 20 patients with a LVEF of more than 40% (Group 2. Gas exchange, respiration biomechanics, and central hemodynamic (CH parameters were monitored (a Vigilance monitor (Edvard LifeScience. Alveolar mobilization was carried out on Drager Evita-2 apparatuses in the BIPAP mode, by taking into account the previous artificial ventilation (AV parameters. The low pressure phase corresponded to the positive end-expiratory pressure (PEEP with volume AV, the high pressure phase was Pplato; the duration of both phases — that of inspiration and expiration (the high pressure phase was inspiration time; the low pressure phase was expiration time. Then the values of Pplato and PEEP were simultaneously increased by 2 cm H2O with a duration of 10 breathing cycles, by continuously monitoring Vt and SaO2 over this interval. By continuously monitoring Vt, a stepwise increase in PEEP and Pplato was continued until there was a Vt reduction or a negative impact of AV on CH. All alveoli were considered to be open when the maximum Vt and SaO2 were achieved. Conclusion. In Group 1 patients with Pinsp of 27—30 cm H2O, PEEP of 10—12 cm H2O, there are increases in PaO2/FiO2 and Cst. In Group 2, the increase of PaO2/FiO2 and Cst is observed with Pinsp of 30—35 cm H2O and PEEP 12—14 cm H2O. With these AV indices, there is an allowable hemodynamic reduction that results in no negative consequences and development of cardiovascular events. After switching to AV in an individually chosen mode, all

  18. Relative Importance of History of Heart Failure Hospitalization and N-Terminal Pro-B-Type Natriuretic Peptide Level as Predictors of Outcomes in Patients With Heart Failure and Preserved Ejection Fraction

    DEFF Research Database (Denmark)

    Kristensen, Søren L; Jhund, Pardeep S; Køber, Lars

    2015-01-01

    of NT-proBNP (n = 1468) (HR: 3.19; 95% CI: 2.68 to 3.80). In patients with no recent HF hospitalization and NT-proBNP ≤360 pg/ml (n = 1,187), the event rate was 2.43 (95% CI: 2.03 to 2.90) compared with 17.79 (95% CI: 15.77 to 20.07) per 100 person-years when both risk predictors were present (n = 523......; HR: 6.18; 95% CI: 4.96 to 7.69). CONCLUSIONS: Recent hospitalization for HF or an elevated level of NT-proBNP identified patients at higher risk for cardiovascular events, and this risk was increased further when both factors were present.......OBJECTIVES: The aim of this study was to investigate N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels and recent heart failure (HF) hospitalization as predictors of future events in heart failure - preserved ejection fraction (HF-PEF). BACKGROUND: Recently, doubt has been expressed...

  19. Mass ejection in failed supernovae: variation with stellar progenitor

    Science.gov (United States)

    Fernández, Rodrigo; Quataert, Eliot; Kashiyama, Kazumi; Coughlin, Eric R.

    2018-05-01

    We study the ejection of mass during stellar core-collapse when the stalled shock does not revive and a black hole forms. Neutrino emission during the protoneutron star phase causes a decrease in the gravitational mass of the core, resulting in an outward going sound pulse that steepens into a shock as it travels out through the star. We explore the properties of this mass ejection mechanism over a range of stellar progenitors using spherically symmetric, time-dependent hydrodynamic simulations that treat neutrino mass-loss parametrically and follow the shock propagation over the entire star. We find that all types of stellar progenitor can eject mass through this mechanism. The ejected mass is a decreasing function of the surface gravity of the star, ranging from several M⊙ for red supergiants to ˜0.1 M⊙ for blue supergiants and ˜10-3 M⊙ for Wolf-Rayet stars. We find that the final shock energy at the surface is a decreasing function of the core-compactness, and is ≲ 1047-1048 erg in all cases. In progenitors with a sufficiently large envelope, high core-compactness, or a combination of both, the sound pulse fails to unbind mass. Successful mass ejection is accompanied by significant fallback accretion that can last from hours to years. We predict the properties of shock breakout and thermal plateau emission produced by the ejection of the outer envelope of blue supergiant and Wolf-Rayet progenitors in otherwise failed supernovae.

  20. Two-Stage Dynamics of In Vivo Bacteriophage Genome Ejection

    Science.gov (United States)

    Chen, Yi-Ju; Wu, David; Gelbart, William; Knobler, Charles M.; Phillips, Rob; Kegel, Willem K.

    2018-04-01

    Biopolymer translocation is a key step in viral infection processes. The transfer of information-encoding genomes allows viruses to reprogram the cell fate of their hosts. Constituting 96% of all known bacterial viruses [A. Fokine and M. G. Rossmann, Molecular architecture of tailed double-stranded DNA phages, Bacteriophage 4, e28281 (2014)], the tailed bacteriophages deliver their DNA into host cells via an "ejection" process, leaving their protein shells outside of the bacteria; a similar scenario occurs for mammalian viruses like herpes, where the DNA genome is ejected into the nucleus of host cells, while the viral capsid remains bound outside to a nuclear-pore complex. In light of previous experimental measurements of in vivo bacteriophage λ ejection, we analyze here the physical processes that give rise to the observed dynamics. We propose that, after an initial phase driven by self-repulsion of DNA in the capsid, the ejection is driven by anomalous diffusion of phage DNA in the crowded bacterial cytoplasm. We expect that this two-step mechanism is general for phages that operate by pressure-driven ejection, and we discuss predictions of our theory to be tested in future experiments.

  1. Highly charged ions at rest: The HITRAP project at GSI

    International Nuclear Information System (INIS)

    Herfurth, F.; Beier, T.; Dahl, L.; Eliseev, S.; Heinz, S.; Kester, O.; Kluge, H.-J.; Kozhuharov, C.; Maero, G.; Quint, W.

    2005-01-01

    A decelerator will be installed at GSI in order to provide and study bare heavy nuclei or heavy nuclei with only few electrons at very low energies or even at rest. Highly-charged ions will be produced by stripping at relativistic energies. After electron cooling and deceleration in the Experimental Storage Ring the ions are ejected out of the storage ring at 4 MeV/u and further decelerated in a combination of an IH and RFQ structure. Finally, they are injected into a Penning trap where the ions are cooled to 4 K. From here, the ions can be transferred in a quasi dc or in a pulsed mode to different experimental setups. This article describes the technical concepts of this project as well as planned key experiments

  2. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Minardi Giovanni

    2006-09-01

    Full Text Available Abstract Background The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm in relatively aged patients at mean 24 months follow-up. Methods and results The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years. All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min. The following parameters were evaluated at rest and/or under DSE: heart rate (HR, ejection fraction (EF, cardiac output (CO, peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG, effective orifice area (EOA, indexed EOA (EOAi, left ventricular mass (LVM, indexed LVM (LVMi, Velocity Time Integral at left ventricular outflow tract (VTI LVOT and transvalvular (Aortic VTI, Doppler velocity index (DVI. At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm2 and 0.76 ± 0.2 cm2/m2; DVI was normal (0.50 ± 0.1. At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m2 to 191 ± 23.8g and 114.5 ± 10.6g/m2, respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg, MnPG (up to 43.2 ± 12.7mmHg. EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm2, 0.75 ± 0.3cm2/m2 and 0.48 ± 0.1 respectively. Two patients developed significant intraventricular gradients. Conclusion These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic

  3. Effect of Natriuretic Peptide-Guided Therapy on Hospitalization or Cardiovascular Mortality in High-Risk Patients With Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.

    Science.gov (United States)

    Felker, G Michael; Anstrom, Kevin J; Adams, Kirkwood F; Ezekowitz, Justin A; Fiuzat, Mona; Houston-Miller, Nancy; Januzzi, James L; Mark, Daniel B; Piña, Ileana L; Passmore, Gayle; Whellan, David J; Yang, Hongqiu; Cooper, Lawton S; Leifer, Eric S; Desvigne-Nickens, Patrice; O'Connor, Christopher M

    2017-08-22

    The natriuretic peptides are biochemical markers of heart failure (HF) severity and predictors of adverse outcomes. Smaller studies have evaluated adjusting HF therapy based on natriuretic peptide levels ("guided therapy") with inconsistent results. To determine whether an amino-terminal pro-B-type natriuretic peptide (NT-proBNP)-guided treatment strategy improves clinical outcomes vs usual care in high-risk patients with HF and reduced ejection fraction (HFrEF). The Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure (GUIDE-IT) study was a randomized multicenter clinical trial conducted between January 16, 2013, and September 20, 2016, at 45 clinical sites in the United States and Canada. This study planned to randomize 1100 patients with HFrEF (ejection fraction ≤40%), elevated natriuretic peptide levels within the prior 30 days, and a history of a prior HF event (HF hospitalization or equivalent) to either an NT-proBNP-guided strategy or usual care. Patients were randomized to either an NT-proBNP-guided strategy or usual care. Patients randomized to the guided strategy (n = 446) had HF therapy titrated with the goal of achieving a target NT-proBNP of less than 1000 pg/mL. Patients randomized to usual care (n = 448) had HF care in accordance with published guidelines, with emphasis on titration of proven neurohormonal therapies for HF. Serial measurement of NT-proBNP testing was discouraged in the usual care group. The primary end point was the composite of time-to-first HF hospitalization or cardiovascular mortality. Prespecified secondary end points included all-cause mortality, total hospitalizations for HF, days alive and not hospitalized for cardiovascular reasons, the individual components on the primary end point, and adverse events. The data and safety monitoring board recommended stopping the study for futility when 894 (median age, 63 years; 286 [32%] women) of the planned 1100 patients had been enrolled with

  4. Ejection and Lofting of Dust from Hypervelocity Impacts on the Moon

    Science.gov (United States)

    Hermalyn, B.; Schultz, P. H.

    2011-12-01

    Hypervelocity impact events mobilize and redistribute fine-grained regolith dust across the surfaces of planetary bodies. The ejecta mass-velocity distribution controls the location and emplacement of these materials. The current flux of material falling on the moon is dominated by small bolides and should cause frequent impacts that eject dust at high speeds. For example, approximately 25 LCROSS-sized (~20-30m diameter) craters are statistically expected to be formed naturally on the moon during any given earth year. When scaled to lunar conditions, the high-speed component of ejecta from hypervelocity impacts can be lofted for significant periods of time (as evidenced by the LCROSS mission results, c.f., Schultz, et al., 2010, Colaprete, et al., 2010). Even at laboratory scales, ejecta can approach orbital velocities; the higher impact speeds and larger projectiles bombarding the lunar surface may permit a significant portion of material to be launched closer to escape velocity. When these ejecta return to the surface (or encounter local topography), they impact at hundreds of meters per second or faster, thereby "scouring" the surface with low mass oblique impacts. While these high-speed ejecta represent only a small fraction of the total ejected mass, the lofting and subsequent ballistic return of this dust has the highest mobilization potential and will be directly applicable to the upcoming LADEE mission. A suite of hypervelocity impact experiments into granular materials was performed at the NASA Ames Vertical Gun Range (AVGR). This study incorporates both canonical sand targets and air-fall pumice dust to simulate the mechanical properties of lunar regolith. The implementation of a Particle Tracking Velocimetry (PTV) technique permits non-intrusive measurement of the ejecta velocity distribution within the ejecta curtain by following the path of individual ejecta particles. The PTV system developed at the AVGR uses a series of high-speed cameras (ranging

  5. Non-invasive evaluation of regional function of the left ventricle

    International Nuclear Information System (INIS)

    Schad, N.; Nickel, O.

    1980-01-01

    Assessment of regional left ventricular function with first pass angiocardiography in the RAO view almost entirely depends on high image statistics, accurate border definition and background subtraction, as well as an analysis of so called functional images which regionally measure and illustrate functional change during heart action. During first bolus transit the multicrystal camera gives an average of 300,000 cts/sec allowing precise border definition because of steepness of count changes at the LV-border. A varying background adjacent to each border point and also over the LV is subtracted. Measurements of segmental hemiaxis shortening and of zonal ejection fractions in the three zones supplied by the major coronary arteries have been performed. Clinical applications comprise examinations at rest, peak exercise, after nitroglycerin administration and after bypass graft surgery. Wall motion measured by means of hemiaxis shortening (210 segments) showed good correlation with angiocardiography in 91% of segments with normokinesis, in 90% asynergic and 88% of hypokinetic segments. Functional images corrected false negativ and false positiv wall motion measurements. In patients after myocardial infarction, there was (after NTG-administration) a significant increase in hemiaxis shortening in asynergic segment, but not in dyskinesias. Exercise studies in patients with wall motion disorders showed a significantly higher increase in global ejection fraction in patients with resting EF-values and 58% than above that value. Zonal ejection fractions after bypass surgery showed an average increase of 6.4 points if complete vascularization was performed, but no zonal increase or decrease when vascularization was incomplete or the zone included a previous myocardial infarction. (orig.) [de

  6. Application of the four formula of software ECToolbox for the assessment of left ventricular ejection fraction in myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Xia Wei; Ni Jing; Zhuang Juhua; Hu Cuihua

    2014-01-01

    Objective: To compare the four formula of software programs ECToolbox for the assessment of left ventricular ejection fraction (LVEF) with equilibrium radionuclide ventriculography. And to calculate the normal cutoff values for the four formula. Methods: A total of 103 patients (59 men, 44 women) were recruited into the study. Thirty-eight patients had known CAD and sixty-five were referred with suspicion of CAD. All the patients underwent equilibrium radionuclide ventriculograph (ERNV) and ECG-gated myocardial perfusion SPECT (GMPS) as the standard protocol. LVEF values were separately calculated with formula R_0, R_1, R_2, R_3 of ECToolbox software, and the results were compared with LVEF values from ERNV. The normal cutoff values for the four formula were calculated by using normal cutoff values greater than or equal to 50% in ERNV as the classifying variable. Results: The mean LVEF on ERNV was 54.6% ± 17.5%. The mean LVEF values for formula R_0, R_1, R_2, R_3 were 64.1% ± 15.7%, 56.3% ± 15.1%, 69.9% ± 17.9%, 56.3% ± 13.6%, respectively. On correlation analysis, a very strong positive correlation was observed between LVEF values derived by ERNV and those derived by the four formula (all of r values were greater than 0.85, P O.05). Normal cutoff values for LVEF on R_0, R_1, R_2, R_3 were 56.5%, 51.5%, 64.5%, 52.5%, respectively, using a 50% or more cutoff value on ERNV. Conclusion: A strong correlation was observed among the four formula of ECToolbox software programs when compared with ERNV. However, there are subtle differences in the objective values of LVEF generated by individual calculation methods, which must be taken into account for clinical studies. (authors)

  7. Inspiratory Muscle Training and Functional Electrical Stimulation for Treatment of Heart Failure With Preserved Ejection Fraction: The TRAINING-HF Trial.

    Science.gov (United States)

    Palau, Patricia; Domínguez, Eloy; López, Laura; Ramón, José María; Heredia, Raquel; González, Jessika; Santas, Enrique; Bodí, Vicent; Miñana, Gema; Valero, Ernesto; Mollar, Anna; Bertomeu González, Vicente; Chorro, Francisco J; Sanchis, Juan; Lupón, Josep; Bayés-Genís, Antoni; Núñez, Julio

    2018-03-16

    Despite the prevalence of heart failure with preserved ejection fraction (HFpEF), there is currently no evidence-based effective therapy for this disease. This study sought to evaluate whether inspiratory muscle training (IMT), functional electrical stimulation (FES), or a combination of both (IMT + FES) improves 12- and 24-week exercise capacity as well as left ventricular diastolic function, biomarker profile, and quality of life in HFpEF. A total of 61 stable symptomatic patients (New York Heart Association II-III) with HFpEF were randomized (1:1:1:1) to receive a 12-week program of IMT, FES, or IMT + FES vs usual care. The primary endpoint of the study was to evaluate change in peak exercise oxygen uptake at 12 and 24 weeks. Secondary endpoints were changes in quality of life, echocardiogram parameters, and prognostic biomarkers. We used a mixed-effects model for repeated-measures to compare endpoints changes. Mean age and peak exercise oxygen uptake were 74 ± 9 years and 9.9 ± 2.5mL/min/kg, respectively. The proportion of women was 58%. At 12 weeks, the mean increase in peak exercise oxygen uptake (mL/kg/min) compared with usual care was 2.98, 2.93, and 2.47 for IMT, FES, and IMT + FES, respectively (P < .001) and this beneficial effect persisted after 6 months (1.95, 2.08, and 1.56; P < .001). Significant increases in quality of life scores were found at 12 weeks (P < .001). No other changes were found. In HFpEF patients with low aerobic capacity, IMT and FES were associated with a significant improvement in exercise capacity and quality of life. This trial was registered at ClinicalTrials.gov (Identifier: NCT02638961).. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Effect of Switching from Cilnidipine to Azelnidipine on Cardiac Sympathetic Nerve Function in Patients with Heart Failure Preserved Ejection Fraction.

    Science.gov (United States)

    Kiuchi, Shunsuke; Hisatake, Shinji; Kabuki, Takayuki; Oka, Takashi; Dobashi, Shintaro; Fujii, Takahiro; Ikeda, Takanori

    2018-01-27

    Cardiac sympathetic nerve activity is known to play a key role in the development and progression of heart failure (HF). Azelnidipine, an L-type calcium channel blocker (CCB), inhibits the sympathetic nerve activity of the central system. In contrast, cilnidipine, an N-type CCB, inhibits the sympathetic nerve activity of the peripheral system. CCBs are recommended as class IIa in patients with HF preserved ejection fraction (HFpEF); however, there are no comparative data on the difference in effect of cilnidipine and azelnidipine in patients with HFpEF and hypertension. We investigated the difference in effect of azelnidipine compared with cilnidipine in patients with HFpEF. Twenty-four consecutive HF patients who received angiotensin II type1a receptor blocker and beta blocker from April 2013 to January 2015 were enrolled. Cilnidipine was switched to azelnidipine during the follow-up period. Blood pressures, heart rate, blood tests, echocardiography, and 123 I-metaiodobenzylguanidine (MIBG) cardiac-scintigraphy were measured before and after 6 months from azelnidipine administration. B-type natriuretic peptide tended to decrease after switching to azelnidipine; however, there were no significant differences between the pre-state and post-state (pre-state: 118.5 pg/mL and post-state: 78.4 pg/mL, P = 0.137). Other laboratory findings, including catecholamine, also did not change significantly. In echocardiography, there were no significant differences in systolic and diastolic functions at the pre-state and post-state. As for MIBG, there were no significant changes in heart/mediastinum ratio. However, washout rate was significantly reduced (pre-state: 42.9 and post-state: 39.6, P = 0.030). Azelnidipine improved the dysfunction of cardiac sympathetic nerve activity compared with cilnidipine in patients with HFpEF.

  9. Do sodium-glucose co-transporter-2 inhibitors prevent heart failure with a preserved ejection fraction by counterbalancing the effects of leptin? A novel hypothesis.

    Science.gov (United States)

    Packer, Milton

    2018-06-01

    Sodium-glucose co-transporter-2 (SGLT2) inhibitors reduce the risk of serious heart failure events in patients with type 2 diabetes, but little is known about mechanisms that might mediate this benefit. The most common heart failure phenotype in type 2 diabetes is obesity-related heart failure with a preserved ejection fraction (HFpEF). It has been hypothesized that the synthesis of leptin in this disorder leads to sodium retention and plasma volume expansion as well as to cardiac and renal inflammation and fibrosis. Interestingly, leptin-mediated neurohormonal activation appears to enhance the expression of SGLT2 in the renal tubules, and SGLT2 inhibitors exert natriuretic actions at multiple renal tubular sites in a manner that can oppose the sodium retention produced by leptin. In addition, SGLT2 inhibitors reduce the accumulation and inflammation of perivisceral adipose tissue, thus minimizing the secretion of leptin and its paracrine actions on the heart and kidneys to promote fibrosis. Such fibrosis probably contributes to the impairment of cardiac distensibility and glomerular function that characterizes obesity-related HFpEF. Ongoing clinical trials with SGLT2 inhibitors in heart failure are positioned to confirm or refute the hypothesis that these drugs may favourably influence the course of obesity-related HFpEF by their ability to attenuate the secretion and actions of leptin. © 2018 John Wiley & Sons Ltd.

  10. Characterizing the original ejection velocity field of the Koronis family

    Science.gov (United States)

    Carruba, V.; Nesvorný, D.; Aljbaae, S.

    2016-06-01

    An asteroid family forms as a result of a collision between an impactor and a parent body. The fragments with ejection speeds higher than the escape velocity from the parent body can escape its gravitational pull. The cloud of escaping debris can be identified by the proximity of orbits in proper element, or frequency, domains. Obtaining estimates of the original ejection speed can provide valuable constraints on the physical processes occurring during collision, and used to calibrate impact simulations. Unfortunately, proper elements of asteroids families are modified by gravitational and non-gravitational effects, such as resonant dynamics, encounters with massive bodies, and the Yarkovsky effect, such that information on the original ejection speeds is often lost, especially for older, more evolved families. It has been recently suggested that the distribution in proper inclination of the Koronis family may have not been significantly perturbed by local dynamics, and that information on the component of the ejection velocity that is perpendicular to the orbital plane (vW), may still be available, at least in part. In this work we estimate the magnitude of the original ejection velocity speeds of Koronis members using the observed distribution in proper eccentricity and inclination, and accounting for the spread caused by dynamical effects. Our results show that (i) the spread in the original ejection speeds is, to within a 15% error, inversely proportional to the fragment size, and (ii) the minimum ejection velocity is of the order of 50 m/s, with larger values possible depending on the orbital configuration at the break-up.

  11. Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Yang, You Jung; Im, Ki Chun; Hong, Il Ki; Yun, Sung Cheol; Kang, Duk Hyun; Song, Jae Kwan; Moon, Dae Hyuk

    2005-01-01

    Systemic errors in the gated single photon emission computed tomography (SPECT) measurement of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) may occur. We evaluated whether patient-related factors affected the accuracy of EDV, ESV, and EF measured by electrocardiogram-gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. EDV, ESV, and EF were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated EDV and ESV, and overestimated EF, but 4D-MSPECT overestimated all those values (p<0.001). Independent variables that increased the difference in EDV between echocardiography and gated SPECT were decreasing LV end-diastolic wall thickness, decreasing body surface area, female sex and increasing EDV (p< 0.001). Those for ESV were decreasing LV end-systolic wall thickness, female sex, and decreasing ESV (p<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in EF (p< 0.001). Adenosine stress SPECT showed significantly higher EDV and ESV values and a lower EF than did redistribution SPECT (p< 0.001). In determination of EF, QGS demonstrated a smaller bias than did 4D-MSPECT. However, in men with LV hypertrophy, 4D-MSPECT was superior to QGS. Systemic error by gated Tl-201 SPECT is determined by individual patient-characteristics

  12. Relationship between angina pectoris and outcomes in patients with heart failure and reduced ejection fraction: an analysis of the Controlled Rosuvastatin Multinational Trial in Heart Failure (CORONA).

    Science.gov (United States)

    Badar, Athar A; Perez-Moreno, Ana Cristina; Jhund, Pardeep S; Wong, Chih M; Hawkins, Nathaniel M; Cleland, John G F; van Veldhuisen, Dirk J; Wikstrand, John; Kjekshus, John; Wedel, Hans; Watkins, Stuart; Gardner, Roy S; Petrie, Mark C; McMurray, John J V

    2014-12-21

    Angina pectoris is common in patients with heart failure and reduced ejection fraction (HF-REF) but its relationship with outcomes has not been well defined. This relationship was investigated further in a retrospective analysis of the Controlled Rosuvastatin Multinational Trial in Heart Failure (CORONA). Four thousand, eight hundred and seventy-eight patients were divided into three categories: no history of angina and no chest pain at baseline (Group A; n = 1240), past history of angina but no chest pain at baseline (Group B; n = 1353) and both a history of angina and chest pain at baseline (Group C; n = 2285). Outcomes were examined using Kaplan-Meier and Cox regression survival analysis. Compared with Group A, Group C had a higher risk of non-fatal myocardial infarction or unstable angina (HR: 2.36, 1.54-3.61; P angina are at an increased risk of acute coronary syndrome and HF hospitalization. Whether these patients would benefit from more aggressive medical therapy or percutaneous revascularization is not known and merits further investigation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  13. Speeds of coronal mass ejections: SMM observations from 1980 and 1984-1989

    Science.gov (United States)

    Hundhausen, A. J.; Burkepile, J. T.; St. Cyr, O. C.

    1994-01-01

    The speeds of 936 features in 673 coronal mass ejections have been determined from trajectories observed with the Solar Maximum Mission (SMM) coronagraph in 1980 and 1984 to 1989. The distribution of observed speeds has a range (from 5th to 95th percentile) of 35 to 911 km/s; the average and median speeds are 349 and 285 km/s. The speed distributions of some selected classes of mass ejections are significantly different. For example, the speeds of 331 'outer loops' range from 80 to 1042 km/s; the average and median speeds for this class of ejections are 445 and 372 km/s. The speed distributions from each year of SMM observations show significant changes, with the annual average speeds varying from 157 (1984) to 458 km/s (1985). These variations are not simply related to the solar activity cycle; the annual averages from years near the sunspot maxima and minimum are not significantly different. The widths, latitudes, and speeds of mass ejections determined from the SMM observations are only weakly correlated. In particular, mass ejection speeds vary only slightly with the heliographic latitudes of the ejection. High-latitude ejections, which occur well poleward of the active latitudes, have speeds similar to active latitude ejections.

  14. Cost-Effectiveness of Sacubitril-Valsartan Combination Therapy Compared With Enalapril for the Treatment of Heart Failure With Reduced Ejection Fraction.

    Science.gov (United States)

    King, Jordan B; Shah, Rashmee U; Bress, Adam P; Nelson, Richard E; Bellows, Brandon K

    2016-05-01

    The objective of this study was to determine the cost-effectiveness and cost per quality-adjusted life year (QALY) gained of sacubitril-valsartan relative to enalapril for treatment of heart failure with reduced ejection fraction (HFrEF). Compared with enalapril, combination angiotensin receptor-neprilysin inhibition (ARNI), as is found in sacubitril-valsartan, reduces cardiovascular death and heart failure hospitalization rates in patients with HFrEF. Using a Markov model, costs, effects, and cost-effectiveness were estimated for sacubitril-valsartan and enalapril therapies for the treatment of HFrEF. Patients were 60 years of age at model entry and were modeled over a lifetime (40 years) from a third-party payer perspective. Clinical probabilities were derived predominantly from PARADIGM-HF (Prospective Comparison of ARNI With ACEI to Determine Impact on Global Mortality and Morbidity in Heart Failure). All costs and effects were discounted at a 3% rate annually and are presented in 2015 U.S. dollars. In the base case, sacubitril-valsartan, compared with enalapril, was more costly ($60,391 vs. $21,758) and more effective (6.49 vs. 5.74 QALYs) over a lifetime. The cost-effectiveness of sacubitril-valsartan was highly dependent on duration of treatment, ranging from $249,411 per QALY at 3 years to $50,959 per QALY gained over a lifetime. Sacubitril-valsartan may be a cost-effective treatment option depending on the willingness-to-pay threshold. Future investigations should incorporate real-world evidence with sacubitril-valsartan to further inform decision making. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Association between circulating fibroblast growth factor 23, α-Klotho, and the left ventricular ejection fraction and left ventricular mass in cardiology inpatients.

    Directory of Open Access Journals (Sweden)

    Kensaku Shibata

    Full Text Available BACKGROUND: Fibroblast growth factor 23 (FGF23, with its co-receptor Klotho, plays a crucial role in phosphate metabolism. Several recent studies suggested that circulating FGF23 and α-Klotho concentrations might be related to cardiovascular abnormalities in patients with advanced renal failure. PURPOSE: Using data from 100 cardiology inpatients who were not undergoing chronic hemodialysis, the association of circulating levels of FGF23, α-Klotho, and other calcium-phosphate metabolism-related parameters with the left ventricular ejection fraction (LVEF and left ventricular mass (LVM was analyzed. METHODS AND RESULTS: LVEF was measured using the modified Simpson method for apical 4-chamber LV images and the LVM index (LVMI was calculated by dividing the LVM by body surface area. Univariate analysis showed that log transformed FGF23, but not that of α-Klotho, was significantly associated with LVEF and LVMI with a standardized beta of -0.35 (P<0.001 and 0.26 (P<0.05, respectively. After adjusting for age, sex, estimated glomerular filtration rate, and serum concentrations of intact parathyroid hormone, and 25-hydroxyvitamin D as covariates into the statistical model, log-transformed FGF23 was found to be a statistically positive predictor for decreased left ventricular function and left ventricular hypertrophy. CONCLUSIONS: In cardiology department inpatients, circulating FGF23 concentrations were found to be associated with the left ventricular mass and LVEF independent of renal function and other calcium-phosphate metabolism-related parameters. Whether modulation of circulating FGF23 levels would improve cardiac outcome in such a high risk population awaits further investigation.

  16. POWER LEVEL EFFECT IN A PWR ROD EJECTION ACCIDENT

    International Nuclear Information System (INIS)

    Diamond, D.J.; Bromley, B.P.; Aronson, A.L.

    2002-01-01

    The purpose of this study is to determine the effect of the initial power level during a rod ejection accident (REA) on the ejected rod worth and the resulting energy deposition in the fuel. The model used is for the hot zero power (HZP) conditions at the end of a typical fuel cycle for the Three Mile Island Unit 1 pressurized water reactor. PARCS , a transient, three-dimensional, two-group neutron nodal diffusion code, coupled with its own thermal-hydraulics model, is used to perform both steady-state and transient simulations. The worth of an ejected control rod is affected by both power level, and the positions of control banks. As the power level is increased, the worth of a single central control rod tends to drop due to thermal-hydraulic feedback and control bank removal, both of which flatten the radial neutron flux and power distributions. Although the peak fuel pellet enthalpy rise during an REA will be greater for a given ejected rod worth at elevated initial power levels, it is more likely the HZP condition will cause a greater net energy deposition because an ejected rod will have the highest worth at HZP. Thus, the HZP condition can be considered the most conservative in a safety evaluation

  17. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Van Staden, J.A.; Herbst, C.P.; Du Raan, H.; Lotter, M.G.; Otto, A.C.

    2004-01-01

    Full text: Introduction: Gated myocardial perfusion SPECT has been used to calculate left ventricular ejection fraction (LVEF) and left ventricular end-diastolic volume (LVEDV) and has correlated well with conventional methods. However, the comparative accuracy of and correlations across various types of gated SPECT software are not well understood. Materials and methods: Twelve patients participated in a radionuclide gated blood-pool (GBP) study in addition to undergoing 99m Tc-sestamibi gated SPECT. Three different software algorithms, Quantitative Gated SPECT (QGS) from Cedars-Sinai, MultiDim from Stanford University Medical School and GQUANT from Alfa Nuclear were used to compute LVEF and LVEDV. These software algorithms operate in 3-dimensional space, two dependent on surface detection and the other on statistical parameters. The LVEF as calculated from gated SPECT myocardial perfusion images were compared with LVEF calculated from the GBP studies in the same patients to assess accuracy of the three software algorithms. Results: The software success-rate was 92% (11/12 pts) for MultiDim and 100% for the QGS and GQUANT. Agreement between LVEF measured with MultiDim and QGS, MultiDim and GQUANT and QGS and GQUANT were excellent (LVEF-MuItidim 0.80 LVEF QGS +5.02, r = 0.93, LVEF GQUANT = 1.10 LVEF MuItidim -1.33, r 0.90 and LVEF GQUANT = 1.02 LVEF QGS -1.40, r = 0.96). The correlation coefficient for LVEF between gated SPECT and the GBP study was 0.95, 0.95 and 0.97, for MultiDim, GQUANT and QGS, respectively. Conclusion: All 3 software programs showed good correlation between LVEF for gated SPECT and the GBP study. Good agreement for LVEF was observed also between the three software algorithms. However, because each method has unique characteristics that depend on its specific algorithm and thus behaves differently in the various patients, the methods should not be used interchangeably. (author)

  18. The influence of occupant anthropometry and seat position on ejection risk in a rollover.

    Science.gov (United States)

    Atkinson, Theresa; Fras, Andrew; Telehowski, Paul

    2010-08-01

    During rollover crashes, ejection increases an occupant's risk of severe to fatal injury as compared to risks for those retained in the vehicle. The current study examined whether occupant anthropometry might influence ejection risk. Factors such as restraint use/disuse, seating position, vehicle type, and roll direction were also considered in the analysis. The current study examined occupant ejections in 10 years of National Automotive Sampling System (NASS) single-event rollovers of passenger vehicles and light trucks. Statistical analysis of unweighted and weighted ejection data was carried out. No statistically significant differences in ejection rates were found based on occupant height, age, or body mass index. Drivers were ejected significantly more frequently than other occupants: 62 percent of unrestrained drivers were ejected vs. 51 percent unrestrained right front occupants. Second row unrestrained occupants were ejected at rates similar to right front-seated occupants. There were no significant differences in ejection rates for near- vs. far-side occupants. These data suggest that assessment of ejection prevention systems using either a 50th or 5th percentile adult anthropomorphic test dummy (ATD) might provide a reasonable measure of system function for a broad range of occupants. They also support the development of ejection mitigation technologies that extend beyond the first row to protect occupants in rear seat positions. Future studies should consider potential interaction effects (i.e., occupant size and vehicle dimensions) and the influence of occupant size on ejection risk in non-single-event rollovers.

  19. Recurrent mass ejections observed in H-alpha and CIV

    International Nuclear Information System (INIS)

    Schmieder, B.; Simon, G.

    1984-01-01

    Time sequences of recurrent mass ejections have been observed during a coordinated SMY program (Sept. 1, 1980 - Sept. 23, 1980 - Oct. 2, 1980). Comparison of the temporal evolution of H-alpha and CIV brightnesses shows a weak phase lag between H-alpha and CIV maxima, in the case of homologous flares, with CIV brightness maxima preceding H-alpha maxima. The analysis of the variation of the ejection velocities is expected to lead to the determination of an energy balance. Such recurrent ejections could be due to periodic energy storage and periodic reorganization of magnetic field as envisaged to occur for flares, but at lower energy levels

  20. Continuous analysis of parotid saliva during resting and short-duration simulated chewing

    NARCIS (Netherlands)

    Neyraud, E.; Bult, J.H.F.; Dransfield, E.

    2009-01-01

    Objective: Parotid saliva flow is increased by mastication and its composition is also modified. The aim of this work was to clarify the relationships between flow rate, pH and protein concentration, during resting and short-duration simulated chewing, using continuous and fractional saliva

  1. Ejection of the Massive Hydrogen-rich Envelope Timed with the Collapse of the Stripped SN 2014C

    Energy Technology Data Exchange (ETDEWEB)

    Margutti, Raffaella [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA), Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208 (United States); Kamble, A.; Milisavljevic, D.; Drout, M.; Chakraborti, S.; Kirshner, R.; Parrent, J. T.; Patnaude, D.; Soderberg, A. M. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Zapartas, E.; De Mink, S. E. [Anton Pannenkoek Institute for Astronomy, University of Amsterdam, 1090 GE Amsterdam (Netherlands); Chornock, R. [Astrophysical Institute, Department of Physics and Astronomy, 251B Clippinger Lab, Ohio University, Athens, OH 45701 (United States); Risaliti, G. [INAF-Arcetri Astrophysical Observatory, Largo E. Fermi 5, I-50125 Firenze (Italy); Zauderer, B. A. [Center for Cosmology and Particle Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Bietenholz, M. [Department of Physics and Astronomy, York University, Toronto, ON M3J 1P3 (Canada); Cantiello, M. [Kavli Institute for Theoretical Physics, University of California, Santa Barbara, CA 93106 (United States); Chomiuk, L. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Fong, W. [Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Grefenstette, B. [Cahill Center for Astrophysics, 1216 E. California Boulevard, California Institute of Technology, Pasadena, CA 91125 (United States); Guidorzi, C. [University of Ferrara, Department of Physics and Earth Sciences, via Saragat 1, I-44122 Ferrara (Italy); and others

    2017-02-01

    We present multi-wavelength observations of SN 2014C during the first 500 days. These observations represent the first solid detection of a young extragalactic stripped-envelope SN out to high-energy X-rays ∼40 keV. SN 2014C shows ordinary explosion parameters ( E {sub k} ∼ 1.8 × 10{sup 51} erg and M {sub ej} ∼ 1.7 M{sub ⊙}). However, over an ∼1 year timescale, SN 2014C evolved from an ordinary hydrogen-poor supernova into a strongly interacting, hydrogen-rich supernova, violating the traditional classification scheme of type-I versus type-II SNe. Signatures of the SN shock interaction with a dense medium are observed across the spectrum, from radio to hard X-rays, and revealed the presence of a massive shell of ∼1 M {sub ⊙} of hydrogen-rich material at ∼6 × 10{sup 16} cm. The shell was ejected by the progenitor star in the decades to centuries before collapse. This result challenges current theories of massive star evolution, as it requires a physical mechanism responsible for the ejection of the deepest hydrogen layer of H-poor SN progenitors synchronized with the onset of stellar collapse. Theoretical investigations point at binary interactions and/or instabilities during the last nuclear burning stages as potential triggers of the highly time-dependent mass loss. We constrain these scenarios utilizing the sample of 183 SNe Ib/c with public radio observations. Our analysis identifies SN 2014C-like signatures in ∼10% of SNe. This fraction is reasonably consistent with the expectation from the theory of recent envelope ejection due to binary evolution if the ejected material can survive in the close environment for 10{sup 3}–10{sup 4} years. Alternatively, nuclear burning instabilities extending to core C-burning might play a critical role.

  2. Chromospheric Plasma Ejections in a Light Bridge of a Sunspot

    Energy Technology Data Exchange (ETDEWEB)

    Song, Donguk; Chae, Jongchul; Yang, Heesu; Cho, Kyuhyoun; Kwak, Hannah [Astronomy Program, Department of Physics and Astronomy, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Yurchyshyn, Vasyl [Big Bear Solar Observatory, New Jersey Institute of Technology, 40386 North Shore Lane, Big Bear City, CA 92314-9672 (United States); Lim, Eun-Kyung; Cho, Kyung-Suk, E-mail: dusong@astro.snu.ac.kr [Korea Astronomy and Space Science Institute 776, Daedeokdae-ro, Yuseong-gu, Daejeon 34055 (Korea, Republic of)

    2017-02-01

    It is well-known that light bridges (LBs) inside a sunspot produce small-scale plasma ejections and transient brightenings in the chromosphere, but the nature and origin of such phenomena are still unclear. Utilizing the high-spatial and high-temporal resolution spectral data taken with the Fast Imaging Solar Spectrograph and the TiO 7057 Å broadband filter images installed at the 1.6 m New Solar Telescope of Big Bear Solar Observatory, we report arcsecond-scale chromospheric plasma ejections (1.″7) inside a LB. Interestingly, the ejections are found to be a manifestation of upwardly propagating shock waves as evidenced by the sawtooth patterns seen in the temporal-spectral plots of the Ca ii 8542 Å and H α intensities. We also found a fine-scale photospheric pattern (1″) diverging with a speed of about 2 km s{sup −1} two minutes before the plasma ejections, which seems to be a manifestation of magnetic flux emergence. As a response to the plasma ejections, the corona displayed small-scale transient brightenings. Based on our findings, we suggest that the shock waves can be excited by the local disturbance caused by magnetic reconnection between the emerging flux inside the LB and the adjacent umbral magnetic field. The disturbance generates slow-mode waves, which soon develop into shock waves, and manifest themselves as the arcsecond-scale plasma ejections. It also appears that the dissipation of mechanical energy in the shock waves can heat the local corona.

  3. Chromospheric Plasma Ejections in a Light Bridge of a Sunspot

    Science.gov (United States)

    Song, Donguk; Chae, Jongchul; Yurchyshyn, Vasyl; Lim, Eun-Kyung; Cho, Kyung-Suk; Yang, Heesu; Cho, Kyuhyoun; Kwak, Hannah

    2017-02-01

    It is well-known that light bridges (LBs) inside a sunspot produce small-scale plasma ejections and transient brightenings in the chromosphere, but the nature and origin of such phenomena are still unclear. Utilizing the high-spatial and high-temporal resolution spectral data taken with the Fast Imaging Solar Spectrograph and the TiO 7057 Å broadband filter images installed at the 1.6 m New Solar Telescope of Big Bear Solar Observatory, we report arcsecond-scale chromospheric plasma ejections (1.″7) inside a LB. Interestingly, the ejections are found to be a manifestation of upwardly propagating shock waves as evidenced by the sawtooth patterns seen in the temporal-spectral plots of the Ca II 8542 Å and Hα intensities. We also found a fine-scale photospheric pattern (1″) diverging with a speed of about 2 km s-1 two minutes before the plasma ejections, which seems to be a manifestation of magnetic flux emergence. As a response to the plasma ejections, the corona displayed small-scale transient brightenings. Based on our findings, we suggest that the shock waves can be excited by the local disturbance caused by magnetic reconnection between the emerging flux inside the LB and the adjacent umbral magnetic field. The disturbance generates slow-mode waves, which soon develop into shock waves, and manifest themselves as the arcsecond-scale plasma ejections. It also appears that the dissipation of mechanical energy in the shock waves can heat the local corona.

  4. Cobalt irradiation box ejection accident of ETRR-2

    International Nuclear Information System (INIS)

    El-Messiry, A.M.

    2000-01-01

    The new Egyptian test and research reactor number 2 ETRR-2, MTR type, is now under operational tests. It has a main central irradiation channel for the purpose of Co 60 isotope production with an intended rated capacity of 50000 Ci per year. The reactivity introduced in the reactor due to accidental ejection of the Co 60 irradiation box (CIB) should be discussed. This reactivity insertion accident (RIA) may be fast or slow with maximum reactivity worth 2.9428 $. The CIB may move with constant speed or variable acceleration according to its initial speed and the applied forces. This results in a linear, parabolic or sinusoidal motion, which in turn affects the reactivity insertion rate (RIR). The present work analyzes this type of perturbation during normal operating conditions: 22 MW full power and 1900 kg s -1 forced core cooling flow. The work serves as a part of the safety evaluation process applicable to similar MTR cores. The RIA code TRANSP20 is developed for this study. It simulates various types of RIR, fast or slow resulting from different CIB ejections. Scram signal due to power, period, inlet and outlet temperatures, or temperature difference is expected to activate the shutdown system. The work presents five case studies, two for fast ejection and three for slow. The transient behavior of the reactor during this is illustrated. The results show that the reactor can withstand slow ejection if the scram is available. However, for fast ejection the scram system does not prevent the clad temperature from exceeding safety limits. Recommendations to prevent or mitigate this accident are highlighted. (orig.)

  5. Speckle tracking echocardiography derived 2-dimensional myocardial strain predicts left ventricular function and mass regression in aortic stenosis patients undergoing aortic valve replacement.

    Science.gov (United States)

    Staron, Adam; Bansal, Manish; Kalakoti, Piyush; Nakabo, Ayumi; Gasior, Zbigniew; Pysz, Piotr; Wita, Krystian; Jasinski, Marek; Sengupta, Partho P

    2013-04-01

    Regression of left ventricular (LV) mass in severe aortic stenosis (AS) following aortic valve replacement (AVR) reduces the potential risk of sudden death and congestive heart failure associated with LV hypertrophy. We investigated whether abnormalities of resting LV deformation in severe AS can predict the lack of regression of LV mass following AVR. Two-dimensional speckle tracking echocardiography (STE) was performed in a total of 100 subjects including 60 consecutive patients with severe AS having normal LV ejection fraction (EF > 50 %) and 40 controls. STE was performed preoperatively and at 4 months following AVR, including longitudinal strain assessed from the apical 4-chamber and 2-chamber views and the circumferential and rotational mechanics measured from the apical short axis view. In comparison with controls, the patients with AS showed a significantly lower LV longitudinal (p regression (>10 %) following AVR. In conclusion, STE can quantify the burden of myocardial dysfunction in patients with severe AS despite the presence of normal LV ejection fraction. Furthermore, resting abnormalities in circumferential strain at LV apex is related with a hemodynamic milieu associated with the lack of LV mass regression during short-term follow up after AVR.

  6. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  7. Relationships between egg-recognition and egg-ejection in a grasp-ejector species.

    Directory of Open Access Journals (Sweden)

    Manuel Soler

    Full Text Available Brood parasitism frequently leads to a total loss of host fitness, which selects for the evolution of defensive traits in host species. Experimental studies have demonstrated that recognition and rejection of the parasite egg is the most common and efficient defence used by host species. Egg-recognition experiments have advanced our knowledge of the evolutionary and coevolutionary implications of egg recognition and rejection. However, our understanding of the proximate mechanisms underlying both processes remains poor. Egg rejection is a complex behavioural process consisting of three stages: egg recognition, the decision whether or not to reject the putative parasitic egg and the act of ejection itself. We have used the blackbird (Turdus merula as a model species to explore the relationship between egg recognition and the act of egg ejection. We have manipulated the two main characteristics of parasitic eggs affecting egg ejection in this grasp-ejector species: the degree of colour mimicry (mimetic and non-mimetic, which mainly affects the egg-recognition stage of the egg-rejection process and egg size (small, medium and large, which affects the decision to eject, while maintaining a control group of non-parasitized nests. The behaviour of the female when confronted with an experimental egg was filmed using a video camera. Our results show that egg touching is an indication of egg recognition and demonstrate that blackbirds recognized (i.e., touched non-mimetic experimental eggs significantly more than mimetic eggs. However, twenty per cent of the experimental eggs were touched but not subsequently ejected, which confirms that egg recognition does not necessarily mean egg ejection and that accepting parasitic eggs, at least sometimes, is the consequence of acceptance decisions. Regarding proximate mechanisms, our results show that the delay in egg ejection is not only due to recognition problems as usually suggested, given that experimental

  8. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  9. Validation of a novel modified wall motion score for estimation of left ventricular ejection fraction in ischemic and non-ischemic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Scholl, David, E-mail: David.Scholl@utoronto.ca [Imaging Research Laboratories, Robarts Research Institute, London, Ontario (Canada); Kim, Han W., E-mail: hanwkim@gmail.com [Duke Cardiovascular Magnetic Resonance Center, Division of Cardiology, Duke University, NC (United States); Shah, Dipan, E-mail: djshah@tmhs.org [The Methodist DeBakey Heart Center, Houston, TX (United States); Fine, Nowell M., E-mail: nowellfine@gmail.com [Division of Cardiology, Department of Medicine, Schulich School of Medicine and Dentistry, University of Western Ontario (Canada); Tandon, Shruti, E-mail: standon4@uwo.ca [Division of Cardiology, Department of Medicine, Schulich School of Medicine and Dentistry, University of Western Ontario (Canada); Thompson, Terry, E-mail: thompson@lawsonimaging.ca [Lawson Health Research Institute, London, Ontario (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario (Canada); Drangova, Maria, E-mail: mdrangov@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London, Ontario (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario (Canada); White, James A., E-mail: jwhite@imaging.robarts.ca [Division of Cardiology, Department of Medicine, Schulich School of Medicine and Dentistry, University of Western Ontario (Canada); Lawson Health Research Institute, London, Ontario (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario (Canada)

    2012-08-15

    Background: Visual determination of left ventricular ejection fraction (LVEF) by segmental scoring may be a practical alternative to volumetric analysis of cine magnetic resonance imaging (MRI). The accuracy and reproducibility of this approach for has not been described. The purpose of this study was to validate a novel segmental visual scoring method for LVEF estimation using cine MRI. Methods: 362 patients with known or suspected cardiomyopathy were studied. A modified wall motion score (mWMS) was used to blindly score the wall motion of all cardiac segments from cine MRI imaging. The same datasets were subjected to blinded volumetric analysis using endocardial contour tracing. The population was then separated into a model cohort (N = 181) and validation cohort (N = 181), with the former used to derive a regression equation of mWMS versus true volumetric LVEF. The validation cohort was then used to test the accuracy of this regression model to estimate the true LVEF from a visually determined mWMS. Reproducibility testing of mWMS scoring was performed upon a randomly selected sample of 20 cases. Results: The regression equation relating mWMS to true LVEF in the model cohort was: LVEF = 54.23 - 0.5761 Multiplication-Sign mWMS. In the validation cohort this equation produced a strong correlation between mWMS-derived LVEF and true volumetric LVEF (r = 0.89). Bland and Altman analysis showed no systematic bias in the LVEF estimated using the mWMS (-0.3231%, 95% limits of agreement -12.22% to 11.58%). Inter-observer and intra-observer reproducibility was excellent (r = 0.93 and 0.97, respectively). Conclusion: The mWMS is a practical tool for reporting regional wall motion and provides reproducible estimates of LVEF from cine MRI.

  10. Myocardial fibrosis burden predicts left ventricular ejection fraction and is associated with age and steroid treatment duration in duchenne muscular dystrophy.

    Science.gov (United States)

    Tandon, Animesh; Villa, Chet R; Hor, Kan N; Jefferies, John L; Gao, Zhiqian; Towbin, Jeffrey A; Wong, Brenda L; Mazur, Wojciech; Fleck, Robert J; Sticka, Joshua J; Benson, D Woodrow; Taylor, Michael D

    2015-03-26

    Patients with Duchenne muscular dystrophy exhibit progressive cardiac and skeletal muscle dysfunction. Based on prior data, cardiac dysfunction in Duchenne muscular dystrophy patients may be influenced by myocardial fibrosis and steroid therapy. We examined the longitudinal relationship of myocardial fibrosis and ventricular dysfunction using cardiac magnetic resonance in a large Duchenne muscular dystrophy cohort. We reviewed 465 serial cardiac magnetic resonance studies (98 Duchenne muscular dystrophy patients with ≥4 cardiac magnetic resonance studies) for left ventricular ejection fraction (LVEF) and presence of late gadolinium enhancement (LGE), a marker for myocardial fibrosis. LVEF was modeled by examining LGE status, myocardial fibrosis burden (as assessed by the number of LGE-positive left ventricular segments), patient age, and steroid treatment duration. An age-only model demonstrated that LVEF declined 0.58 ± 0.10% per year. In patients with both LGE-negative and LGE-positive studies (n=51), LVEF did not decline significantly over time if LGE was absent but declined 2.2 ± 0.31% per year when LGE was present. Univariate modeling showed significant associations between LVEF and steroid treatment duration, presence of LGE, and number of LGE-positive left ventricular segments; multivariate modeling showed that LVEF declined by 0.93 ± 0.09% for each LGE-positive left ventricular segment, whereas age and steroid treatment duration were not significant. The number of LGE-positive left ventricular segments increased with age, and longer steroid treatment duration was associated with lower age-related increases. Progressive myocardial fibrosis, as detected by LGE, was strongly correlated with the LVEF decline in Duchenne muscular dystrophy patients. Longer steroid treatment duration was associated with a lower age-related increase in myocardial fibrosis burden. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley

  11. Prevalence and characteristics of coronary artery disease in heart failure with preserved and mid-range ejection fractions: A systematic angiography approach.

    Science.gov (United States)

    Trevisan, Lory; Cautela, Jennifer; Resseguier, Noemie; Laine, Marc; Arques, Stephane; Pinto, Johan; Orabona, Morgane; Barraud, Jeremie; Peyrol, Michael; Paganelli, Franck; Bonello, Laurent; Thuny, Franck

    2018-02-01

    Guidelines recommend careful screening and treatment of coronary artery disease (CAD) in heart failure with preserved or mid-range ejection fraction (HFpEF/HFmEF). We aimed to determine the prevalence and characteristics of CAD using a prospective systematic coronary angiography approach. A systematic coronary angiography protocol was applied in consecutive patients admitted for HFpEF/HFmEF during a 6-month period in a single centre. History of CAD and results of angiography, including revascularization, were reported. Of the 164 patients with HFpEF/HFmEF who were included, an angiography assessment was applied in 108 (66%) (median age: 79 years [interquartile range: 70-85 years]; 54% were women). In our analysis, 64% (95% confidence interval [CI] 55-73%) of patients had a significant coronary stenosis corresponding to a global CAD prevalence of 80% (95% CI 73-88%). The prevalence of CAD was similar for HFpEF and HFmEF. The left main coronary artery presented a significant stenosis in 6.5% of cases and 39% of patients had a two- or three-vessel disease. The rate of significant coronary stenosis was non-significantly higher in patients with a history of CAD. Patients with HFpEF/HFmEF with and without CAD did not differ in clinically meaningful ways, in terms of symptoms or laboratory and echocardiography results. This strategy led to complete revascularization in 36% of patients with significant stenosis and in 23% of all patients with HFpEF/HFmEF. Our study differs from others in that we used a systematic angiography approach. The results suggest a much higher prevalence of CAD in HFpEF/HFmEF than previously reported and should encourage clinicians to aggressively identify this co-morbidity. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Parametric study of a reactivity accident in a pressurized water reactor: control rod cluster ejection

    International Nuclear Information System (INIS)

    Chesnel, A.

    1985-01-01

    This research thesis concerns a class 4 accident in a PWR: the ejection of a control rod cluster from the reactor core. It aims at defining, for such an accident, the envelope values which relate the reactivity to the hot spot factor within the frame of a mode A control. The report describes the physical phenomena and their modelling during the considered transient. It presents a simple mathematical solution of the accident which shows that the main neutron parameters are the released reactivity, the delayed neutron fraction, the Doppler coefficient, and the hot spot factor. It reports a temperature sensitivity study, and discusses three-dimensional calculations of irradiation distributions

  13. Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

    Science.gov (United States)

    Scott, Jessica M.; Matz, Timothy; Caine, Timothy; Martin, David S.; Downs, Meghan; Ploutz-Snyder, Lori

    2014-01-01

    BACKGROUND Current techniques used to assess cardiac function following spaceflight or head-down tilt bed rest (HDTBR) involve invasive and time consuming procedures such as Swan-Ganz catheterization or cardiac magnetic resonance imaging. An alternative approach, echocardiography, can monitor cardiac morphology and function via sequential measurements of left ventricular (LV) mass and ejection fraction (EF). However, LV mass and EF are insensitive measures of early (subclinical) cardiac deconditioning, and a decrease in LV mass and EF become evident only once significant deconditioning has already occurred. The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the magnitude and time course of cardiac deconditioning. METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR-2), during (BR31, 70), and following (BR+4hr) HDTBR. Multi-level modeling was used to evaluate the effect of HDTBR condition (Control, Exercise) on cardiac variables. RESULTS Compared to BR-2, longitudinal (BR-2: - 19.0 +/- 1.8%; BR31: -15.9 +/- 2.4%; BR70: -14.9 +/- 2.4%; BR+4hr: -16.0 +/- 2.1%) and radial (BR-2: 15.0 +/- 1.9%; BR31: 12.3 +/- 2.4%; BR70: 11.3 +/- 2.2%; BR+4hr: 13.5 +/- 2.5% ) strains were significantly impaired during and following bed rest (pmechanics for longitudinal strain (BR-2: -19.1 +/- 1.5%; BR 31: -19.0 +/- 2.4%; BR70: -19.1 +/- 2.7%; BR+4hr: -17.8 +/- 2.1%), radial strain (BR-2: 13.8 +/- 2.4; BR31: 14.7 +/- 2.4; BR70: 14.4 +/- 1.6; BR+4hr: 14.4 +/- 2.4), and twist (BR-2: 17.8 +/- 3.6deg; BR31: 18.0 +/- 3.6deg; BR70: 18.2 +/- 5.9deg; BR+4hr: 18.3 +/- 4.2deg). CONCLUSIONS Speckle-tracking echocardiography provides important

  14. Left ventricular ejection fraction and left atrium diameter related to new-onset atrial fibrillation following acute myocardial infarction: a systematic review and meta-analysis.

    Science.gov (United States)

    Zeng, Rui-Xiang; Chen, Mao-Sheng; Lian, Bao-Tao; Liao, Peng-Da; Zhang, Min-Zhou

    2017-10-06

    New-onset atrial fibrillation (NOAF) occurs frequently in patients with acute myocardial infarction (AMI), and is associated with increased subsequent cardiovascular mortality. However, only a few studies directly evaluated the relationship of left ventricular ejection fraction (LVEF) or left atrium diameter (LAD) and NOAF following AMI. MEDLINE ® , EMBASE ® and the Cochrane Library were carried out to find studies until January 2017. Pooled mean difference (MD) and 95% confidence interval (CI) were calculated to evaluate the value of LVEF and LAD in the prediction of NOAF after AMI. We performed sensitivity analyses to explore the potential sources of heterogeneity. Statistical analyses were carried out using the Revman 5.3. We included 10 qualifying studies comprising a total of 708 patients with NOAF and 6785 controls. Overall, decreased LVEF and increased LAD levels had a significant positive association with NOAF in patients with AMI. The MD in the LVEF levels between the patients with and those without NOAF was -4.91 units (95% Cl: -5.70 to -4.12), test for overall effect z-score = 12.18 ( p < 0.00001, I 2 = 35%). Moreover, in a subgroup analysis, the MD for LAD and NOAF was 2.55 units (95% Cl: 1.91 to 3.19), test for overall effect z-score = 7.80 ( p < 0.00001, I 2 = 57%). Our meta-analysis demonstrated that both decreased LVEF and increased LAD levels were associated with greater risk of NOAF following AMI.

  15. Ejection Regimes in Picosecond Laser-Induced Forward Transfer of Metals

    NARCIS (Netherlands)

    Pohl, Ralph; Visser, C.W.; Römer, Gerardus Richardus, Bernardus, Engelina; Lohse, Detlef; Sun, Chao; Huis in 't Veld, Bert

    2015-01-01

    Laser-induced forward transfer (LIFT) is a 3D direct-write method suitable for precision printing of various materials, including pure metals. To understand the ejection mechanism and thereby improve deposition, here we present visualizations of ejection events at high-spatial (submicrometer) and

  16. Association of N-terminal pro-brain natriuretic peptide with the severity of coronary artery disease in patients with normal left ventricular ejection fraction.

    Science.gov (United States)

    Wu, Naqiong; Ma, Fenglian; Guo, Yuanlin; Li, Xiaoling; Liu, Jun; Qing, Ping; Xu, Ruixia; Zhu, Chenggang; Jia, Yanjun; Liu, Geng; Dong, Qian; Jiang, Lixin; Li, Jianjun

    2014-01-01

    Backround N-terminal pro-brain natriuretic peptide (NT-proBNP) is a reliable predictor in acute coronary artery disease (CAD). Little is known about patients with stable CAD, especially Chinese patients with CAD. The aim of the present study was to investigate the association of NT-proBNP levels with the severity of CAD in patients with normal left ventricular ejection fraction. A total of 658 consecutive patients were divided into two groups based on angiograms: CAD group (n = 484) and angiographic normal control group (n = 174). The severity of CAD was evaluated by modified Gensini score, and its relationship with NT-proBNP was analyzed. The prevalence of risk factors such as age, male gender, diabetes mellitus (DM), dyslipidemia, smoking, and family history of CAD in the CAD group were higher than that in the control group. In multivariate regression model analysis, age, gender, and DM were determinants of the presence of CAD. NT-pro BNP was found to be an independent predictor for CAD (OR:1.66 (95% CI: 1.06-2.61), P value of 641.15 pmol/L was identified as a cut-off value in the diagnosis or exclusion of CAD (area under curve (AUC) = 0.56, 95% CI: 0.51-0.61). Furthermore, NT-proBNP was positively correlated with Gensini score (r = 0.14, P < 0.001) in patients with CAD. NT-proBNP was an independent predictor for Chinese patients with CAD, suggesting that the NT-proBNP level might be associated with the presence and the severity of CAD.

  17. Simulating AIA observations of a flux rope ejection

    Science.gov (United States)

    Pagano, P.; Mackay, D. H.; Poedts, S.

    2014-08-01

    Context. Coronal mass ejections (CMEs) are the most violent phenomena observed on the Sun. Currently, extreme ultraviolet (EUV) images from the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory (SDO) are providing new insights into the early phase of CME evolution. In particular, observations now show the ejection of magnetic flux ropes from the solar corona and how they evolve into CMEs. While this is the case, these observations are difficult to interpret in terms of basic physical mechanisms and quantities. To fully understand CMEs we need to compare equivalent quantities derived from both observations and theoretical models. This will aid in bridging the gap between observations and models. Aims: To this end, we aim to produce synthesised AIA observations from simulations of a flux rope ejection. To carry this out we include the role of thermal conduction and radiative losses, both of which are important for determining the temperature distribution of the solar corona during a CME. Methods: We perform a simulation where a flux rope is ejected from the solar corona. From the density and temperature of the plasma in the simulation we synthesise AIA observations. The emission is then integrated along the line of sight using the instrumental response function of AIA. Results: We sythesise observations of AIA in the channels at 304 Å, 171 Å, 335 Å, and 94 Å. The synthesised observations show a number of features similar to actual observations and in particular reproduce the general development of CMEs in the low corona as observed by AIA. In particular we reproduce an erupting and expanding arcade in the 304 Å and 171 Å channels with a high density core. Conclusions: The ejection of a flux rope reproduces many of the features found in the AIA observations. This work is therefore a step forward in bridging the gap between observations and models, and can lead to more direct interpretations of EUV observations in terms of flux rope

  18. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  19. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  20. Nuclear medical quality control of transluminal coronary angioplastic (TCA)

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Scherer, D.; Kober, G.; Kaltenbach, M.; Maul, F.D.; Standke, R.; Hoer, G.; Kanemoto, N.

    1984-01-01

    To assess the results of transluminal coronary angioplasty 48 patients with coronary heart disease were investigated at rest and during exercise with the ECG (46 patients), thallium-201 myocardial scintigraphy (26 patients), and equilibrium radionuclide ventriculography (38 patients). Exercise stress test was quantified by means of an ischemia score, myocardial scintigraphy by an vitality index and by corresponding redistribution factors, and radionuclide ventriculography by ejection fraction and maximum systolic volume change as a fraction of enddiastolic volume. The patients were divided into three groups: 36 patients had successful TCA (group 1); 6 patients underwent aortocoronary bypass operation (ACB, group 2); in 6 patients TCA was unsuccessful, they served as control (group 3). On average TCA yielded a reduction of coronary artery stenosis from 83% to 44%. Functional improvement was comparable in group 1 and 2: Ischemia score was reduced significantly. Perfusion index increased, the corresponding redistribution factors decreased. Left ventricular ejection fraction increased at rest and during exercise. Maximum systolic volume change increased correspondingly. Only slight changes were noted in group 3. Three months later 2 of 16 reinvestigated patients showed a restenosis and one a new narrowing distal to the successfully dilated stenosis. Functional deterioration could be demonstrated in these, whilst maintainance of the good functional results was documented in the others. (orig./MG) [de

  1. Two-Stage Dynamics of In Vivo Bacteriophage Genome Ejection

    Directory of Open Access Journals (Sweden)

    Yi-Ju Chen

    2018-05-01

    Full Text Available Biopolymer translocation is a key step in viral infection processes. The transfer of information-encoding genomes allows viruses to reprogram the cell fate of their hosts. Constituting 96% of all known bacterial viruses [A. Fokine and M. G. Rossmann, Molecular architecture of tailed double-stranded DNA phages, Bacteriophage 4, e28281 (2014], the tailed bacteriophages deliver their DNA into host cells via an “ejection” process, leaving their protein shells outside of the bacteria; a similar scenario occurs for mammalian viruses like herpes, where the DNA genome is ejected into the nucleus of host cells, while the viral capsid remains bound outside to a nuclear-pore complex. In light of previous experimental measurements of in vivo bacteriophage λ ejection, we analyze here the physical processes that give rise to the observed dynamics. We propose that, after an initial phase driven by self-repulsion of DNA in the capsid, the ejection is driven by anomalous diffusion of phage DNA in the crowded bacterial cytoplasm. We expect that this two-step mechanism is general for phages that operate by pressure-driven ejection, and we discuss predictions of our theory to be tested in future experiments.

  2. Ejection of a rear facing, golf cart passenger.

    Science.gov (United States)

    Schau, Kyle; Masory, Oren

    2013-10-01

    The following report details the findings of a series of experiments and simulations performed on a commercially available, shuttle style golf cart during several maneuvers involving rapid accelerations of the vehicle. It is determined that the current set of passive restraints on these types of golf carts are not adequate in preventing ejection of a rear facing passenger during rapid accelerations in the forward and lateral directions. Experimental data and simulations show that a hip restraint must be a minimum of 13 in. above the seat in order to secure a rear facing passenger during sharp turns, compared to the current restraint height of 5 in. Furthermore, it is determined that a restraint directly in front of the rear facing passenger is necessary to prevent ejection. In addressing these issues, golf cart manufacturers could greatly reduce the likelihood of injury due to ejection of a rear facing, golf cart passenger. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. 3-D rod ejection analysis using a conservative methodology

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Ho; Park, Jin Woo; Park, Guen Tae; Um, Kil Sup; Ryu, Seok Hee; Lee, Jae Il; Choi, Tong Soo [KEPCO, Daejeon (Korea, Republic of)

    2016-05-15

    The point kinetics model which simplifies the core phenomena and physical specifications is used for the conventional rod ejection accident analysis. The point kinetics model is convenient to assume conservative core parameters but this simplification loses large amount of safety margin. The CHASER system couples the three-dimensional core neutron kinetics code ASTRA, the sub-channel analysis code THALES and the fuel performance analysis code FROST. The validation study for the CHASER system is addressed using the NEACRP three-dimensional PWR core transient benchmark problem. A series of conservative rod ejection analyses for the APR1400 type plant is performed for both hot full power (HFP) and hot zero power (HZP) conditions to determine the most limiting cases. The conservative rod ejection analysis methodology is designed to properly consider important phenomena and physical parameters.

  4. Evidence for direct geographic influences on linguistic sounds: the case of ejectives.

    Directory of Open Access Journals (Sweden)

    Caleb Everett

    Full Text Available We present evidence that the geographic context in which a language is spoken may directly impact its phonological form. We examined the geographic coordinates and elevations of 567 language locations represented in a worldwide phonetic database. Languages with phonemic ejective consonants were found to occur closer to inhabitable regions of high elevation, when contrasted to languages without this class of sounds. In addition, the mean and median elevations of the locations of languages with ejectives were found to be comparatively high. The patterns uncovered surface on all major world landmasses, and are not the result of the influence of particular language families. They reflect a significant and positive worldwide correlation between elevation and the likelihood that a language employs ejective phonemes. In addition to documenting this correlation in detail, we offer two plausible motivations for its existence. We suggest that ejective sounds might be facilitated at higher elevations due to the associated decrease in ambient air pressure, which reduces the physiological effort required for the compression of air in the pharyngeal cavity--a unique articulatory component of ejective sounds. In addition, we hypothesize that ejective sounds may help to mitigate rates of water vapor loss through exhaled air. These explications demonstrate how a reduction of ambient air density could promote the usage of ejective phonemes in a given language. Our results reveal the direct influence of a geographic factor on the basic sound inventories of human languages.

  5. Ejection dynamics of hydrogen molecular ions from methanol in intense laser fields

    International Nuclear Information System (INIS)

    Okino, T; Furukawa, Y; Liu, P; Ichikawa, T; Itakura, R; Hoshina, K; Yamanouchi, K; Nakano, H

    2006-01-01

    The ejection of hydrogen molecular ions from two-body Coulomb explosion processes of methanol (CH 3 OH, CD 3 OH and CH 3 OD) in an intense laser field (800 nm, 60 fs, 0.2 PW cm -2 ) is investigated by a coincidence momentum imaging method. From the coincidence momentum maps, the ejection processes of hydrogen molecular ions, CH 3 OH 2+ → H m + + CH (3-m) OH + (m = 2, 3), CD 3 OH 2+ → D m + + CH (3-m) OH + (m = 2, 3) and CH 3 OD 2+ → H m + + CH (3-m) OD + (m = 2, 3), are identified. Based on the results obtained with isotopically substituted methanol, the isotope effect on the ejection process of hydrogen molecular ions is discussed. Furthermore, the ejection of H/D exchanged hydrogen molecular ions (HD + , HD 2 + and H 2 D + ) is identified, and the timescales for the H/D exchanging processes are estimated from the extent of anisotropy in the ejection directions

  6. Femtosecond pulse-width dependent trapping and directional ejection dynamics of dielectric nanoparticles

    KAUST Repository

    Chiang, Weiyi

    2013-09-19

    We demonstrate that laser pulse duration, which determines its impulsive peak power, is an effective parameter to control the number of optically trapped dielectric nanoparticles, their ejections along the directions perpendicular to polarization vector, and their migration distances from the trapping site. This ability to controllably confine and eject the nanoparticle is explained by pulse width-dependent optical forces exerted on nanoparticles in the trapping site and ratio between the repulsive and attractive forces. We also show that the directional ejections occur only when the number of nanoparticles confined in the trapping site exceeds a definite threshold. We interpret our data by considering the formation of transient assembly of the optically confined nanoparticles, partial ejection of the assembly, and subsequent filling of the trapping site. The understanding of optical trapping and directional ejections by ultrashort laser pulses paves the way to optically controlled manipulation and sorting of nanoparticles. © 2013 American Chemical Society.

  7. Resting state fMRI: A review on methods in resting state connectivity analysis and resting state networks.

    Science.gov (United States)

    Smitha, K A; Akhil Raja, K; Arun, K M; Rajesh, P G; Thomas, Bejoy; Kapilamoorthy, T R; Kesavadas, Chandrasekharan

    2017-08-01

    The inquisitiveness about what happens in the brain has been there since the beginning of humankind. Functional magnetic resonance imaging is a prominent tool which helps in the non-invasive examination, localisation as well as lateralisation of brain functions such as language, memory, etc. In recent years, there is an apparent shift in the focus of neuroscience research to studies dealing with a brain at 'resting state'. Here the spotlight is on the intrinsic activity within the brain, in the absence of any sensory or cognitive stimulus. The analyses of functional brain connectivity in the state of rest have revealed different resting state networks, which depict specific functions and varied spatial topology. However, different statistical methods have been introduced to study resting state functional magnetic resonance imaging connectivity, yet producing consistent results. In this article, we introduce the concept of resting state functional magnetic resonance imaging in detail, then discuss three most widely used methods for analysis, describe a few of the resting state networks featuring the brain regions, associated cognitive functions and clinical applications of resting state functional magnetic resonance imaging. This review aims to highlight the utility and importance of studying resting state functional magnetic resonance imaging connectivity, underlining its complementary nature to the task-based functional magnetic resonance imaging.

  8. Classification of the ejection mechanisms of charged macromolecules from liquid droplets.

    Science.gov (United States)

    Consta, Styliani; Malevanets, Anatoly

    2013-01-28

    The relation between the charge state of a macromolecule and its ejection mechanism from droplets is one of the important questions in electrospray ionization methods. In this article, effects of solvent-solute interaction on the manifestation of the charge induced instability in a droplet are examined. We studied the instabilities in a prototype system of a droplet comprised of charged poly(ethylene glycol) and methanol, acetonitrile, and water solvents. We observed instances of three, previously only conjectured, [S. Consta, J. Phys. Chem. B 114, 5263 (2010)] mechanisms of macroion ejection. The mechanism of ejection of charged macroion in methanol is reminiscent of "pearl" model in polymer physics. In acetonitrile droplets, the instability manifests through formation of solvent spines around the solvated macroion. In water, we find that the macroion is ejected from the droplet through contiguous extrusion of a part of the chain. The difference in the morphology of the instabilities is attributed to the interplay between forces arising from the macroion solvation energy and the surface energy of the droplet interface. For the contiguous extrusion of a charged macromolecule from a droplet, we demonstrate that the proposed mechanism leads to ejection of the macromolecule from droplets with sizes well below the Rayleigh limit. The ejected macromolecule may hold charge significantly higher than that suggested by prevailing theories. The simulations reveal new mechanisms of macroion evaporation that differ from conventional charge residue model and ion evaporation mechanisms.

  9. RESTful NET

    CERN Document Server

    Flanders, Jon

    2008-01-01

    RESTful .NET is the first book that teaches Windows developers to build RESTful web services using the latest Microsoft tools. Written by Windows Communication Foundation (WFC) expert Jon Flanders, this hands-on tutorial demonstrates how you can use WCF and other components of the .NET 3.5 Framework to build, deploy and use REST-based web services in a variety of application scenarios. RESTful architecture offers a simpler approach to building web services than SOAP, SOA, and the cumbersome WS- stack. And WCF has proven to be a flexible technology for building distributed systems not necessa

  10. Resting-state functional MR changes in Alzheimer's disease patients visualized by amplitude of low-frequency fluctuation and fraction of amplitude of low-frequency fluctuation

    International Nuclear Information System (INIS)

    Long Miaomiao; Ni Hongyan; Feng Jie; Zhang Hongtao; Liu Tie; Shen Wen; Qi Ji

    2013-01-01

    Objective: To investigate the difference of amplitude of low-frequency fluctuation (ALFF) and fraction of amplitude of low-frequency fluctuation (fALFF) between Alzheimer's disease (AD)patients and normal aging (NA) controls by voxel-based analysis. Methods: Thirty-one AD patients and 44 NA controls were enrolled in the study. Blood oxygen level dependent functional (BOLD) EPI data were obtained during resting-state by using 32-channel head coil. Data were realigned, normalized and then smoothed with 8 mm FWHM kernel. Resting-state fMRI toolkit (version 1.6) was used to generate ALFF and fALFF images. Independent two sample t-test was performed with SPM5 to compare ALFF and fALFF of AD and NA controls. Pearson correlation analysis was performed to examine the relationship between MMSE score and ALFF, fALFF parameters. The significance level was set to be uncorrected O.001 on the voxel level and 0.05 on the cluster level. Results: AD patients showed increased ALFF in left temporal lobe (0.492 ± 0.119) and right cingulated cortex (0.434 ± 0.093) of AD patients, which were 0.443 ± 0.068 and 0.380 ± 0.081 in NA controls (t = 2.658, 2.227, P < 0.05). Decreased fALFF was found in bilateral posterior cingulate cortices (1.167 ± 0.203) and increased fALFF was found in bilateral temporal lobes (left 1.226 ± 0.127, right 1.146 ± 0.214) with left side dominance, which were 1.453 ± 0.269, 1.134 ± 0.088, 1.014 ± O.132 in NA controls (t =5.001, 3.695, 3.285, P < 0.05). Bilateral temporal ALFF and fALFF correlated with MMSE positively (r = 0.768-0.909, P < 0.05) with left dominance. Conclusion: AD patients showed increased resting-state functional MRI changes correlated with MMSE score in the temporal lobes with left dominance, which indicated left temporal lobe may be the best location for the observation of disease progression in AD patients. (authors)

  11. The natural history of new-onset heart failure with a severely depressed left ventricular ejection fraction: implications for timing of implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Teeter, William A; Thibodeau, Jennifer T; Rao, Krishnasree; Brickner, M Elizabeth; Toto, Kathleen H; Nelson, Lauren L; Mishkin, Joseph D; Ayers, Colby R; Miller, Justin G; Mammen, Pradeep P A; Patel, Parag C; Markham, David W; Drazner, Mark H

    2012-09-01

    Guidelines recommend that patients with new-onset systolic heart failure (HF) receive a trial of medical therapy before an implantable cardiac defibrillator (ICD). This strategy allows for improvement of left ventricular ejection fraction (LVEF), thereby avoiding an ICD, but exposes patients to risk of potentially preventable sudden cardiac death during the trial of medical therapy. We reviewed a consecutive series of patients with HF of <6 months duration with a severely depressed LVEF (<30%) evaluated in a HF clinic (N = 224). The ICD implantation was delayed with plans to reassess LVEF approximately 6 months after optimization of β-blockers. Mortality was ascertained by the National Death Index. Follow-up echocardiograms were performed in 115 of the 224 subjects. Of these, 50 (43%) had mildly depressed or normal LVEF at follow-up ("LVEF recovery") such that an ICD was no longer indicated. In a conservative sensitivity analysis (using the entire study cohort, whether or not a follow-up echocardiogram was obtained, as the denominator), 22% of subjects had LVEF recovery. Mortality at 6, 12, and 18 months in the entire cohort was 2.3%, 4.5%, and 6.8%, respectively. Of 87 patients who tolerated target doses of β-blockers, only 1 (1.1%) died during the first 18 months. Patients with new-onset systolic HF have both a good chance of LVEF recovery and low 6-month mortality. Achievement of target β-blocker dose identifies a very low-risk population. These data support delaying ICD implantation for a trial of medical therapy. Copyright © 2012 Mosby, Inc. All rights reserved.

  12. Comparing characteristics and clinical and echocardiographic outcomes in low-flow vs normal-flow severe aortic stenosis with preserved ejection fraction in an Asian population.

    Science.gov (United States)

    Ngiam, Jinghao Nicholas; Tan, Benjamin Yong-Qiang; Sia, Ching-Hui; Lee, Glenn K M; Kong, William K F; Chan, Yiong-Huak; Poh, Kian-Keong

    2017-05-01

    In severe aortic stenosis (AS), deterioration of left ventricular ejection fraction (LVEF) to 50%) and with paired echocardiography were studied. Univariate and multivariate analyses identified factors associated with LVEF deterioration. Clinical outcomes were determined on follow-up for more than 5 years. Significant LVEF deterioration (to <50%) was seen in 18% of low-flow (initial LVEF 63±8% to 32±9%) and 18% of normal-flow AS (61±7% to 31±12%). Independent factors in low-flow AS were hypertension (OR: 30.7, 95% CI: 2.0-467.6, P=.014) and higher end-systolic wall stress (OR: 1.086, 95% CI: 1.022-1.153, P=.008), compared to normal-flow, which were hypertension (OR: 15.9, 95% CI: 3.1-81.9, P=.001), higher septal E/E' ratio (OR: 1.16, 95% CI: 1.01-1.35, P=.043), lower septal S' velocity (OR: 0.204, 95% CI: 0.061-0.682, P=.010), and higher end-systolic wall stress (OR: 1.051, 95% CI: 1.001-1.104, P=.047). Overall, a third of the cohort experienced MACE, regardless of flow (log-rank 0.048, P=.827). However, aortic valve replacement (AVR) rates were lower in low-flow AS (20% vs 43%, P=.005). Low-flow AS despite normal LVEF appears similar to normal-flow in terms of LVEF deterioration and clinical outcomes in our Asian population. AVR rate was lower even though low-flow may not reflect less severe disease. © 2017, Wiley Periodicals, Inc.

  13. The effect of filtrating and reconstruction method on the left ventricular ejection fraction derived from GSPET. A statistical comparison of angiography and echocardiography

    International Nuclear Information System (INIS)

    Bitarafan, A.; Rajabi, H.

    2008-01-01

    There are different protocols of reconstruction in myocardial gated imaging that produce different values of left ventricular ejection fraction (EF). We attempted to determine how the parameters of reconstruction affect the calculated EF. The results were statistically compared with the values obtained from angiography and echocardiography. In this retrospective study, the data from 23 patients were used. All the patients had the angiographic and the echocardiographic data within 2 weeks before the test. Imaging was performed using a single-head gamma camera using technetium-99 methoxyisobutylisonitrile. The image data were reconstructed using 50 different combinations of the ramp, Hanning, Butterworth, Wiener, and Metz filters. The ordered subset expectation maximization (OSEM) technique was also examined using 12 combinations of iteration and subset. The calculated EF values were analyzed and compared with the echocardiographic and angiographic results. The backprojection technique produced higher values of EF than those derived from echocardiography and angiography. The OSEM on the other hand produced lower values when compared with echocardiography and angiography. On using the backprojection technique, the maximum correlation between the values derived from gated single-photon emission tomography and echocardiography (r=0.88, P<0.01) and angiography (r=0.81, P<0.01) was observed when using the Metz filter (full width at half maximum=5 mm and order=9) and the Gaussian filter (α=3), respectively. In the case of the OSEM technique, the maximum correlation with both angiography and echocardiography was observed when using the iteration=2 and the subset=12. On the average, the backprojection technique produces higher values, and iteration technique produces lower estimation of the EF when compared with angiography and echocardiography. (author)

  14. Detection of infarct size safety threshold for left ventricular ejection fraction impairment in acute myocardial infarction successfully treated with primary percutaneous coronary intervention.

    Science.gov (United States)

    Sciagrà, Roberto; Cipollini, Fabrizio; Berti, Valentina; Migliorini, Angela; Antoniucci, David; Pupi, Alberto

    2013-04-01

    In acute myocardial infarction (AMI) treated by primary percutaneous coronary intervention (PCI), there is a direct relationship between myocardial damage and consequent left ventricular (LV) functional impairment. It is however unclear whether there is a safety threshold below which infarct size does not significantly affect LV ejection fraction (EF). The aim of this study was to evaluate the relationship between infarct size and LVEF in AMI patients treated by successful PCI using a specific statistical approach to identify a possible safety threshold. Among patients with recent AMI submitted to perfusion gated single photon emission computed tomography (SPECT) to define the infarct size, the data of 427 subjects with sizable infarct size were considered. The relationship between infarct size and LVEF was analysed using a simple segmented regression (SSR) model and an iterative algorithm based on robust least squares (RLS) for parameter estimation. The RLS algorithm detected two break points in the SSR model, set at infarct size values of 11.0 and 51.5 %. Because the slope coefficients of the two extreme segments of the regression line were not significant, by constraining such segments to zero slope in the SSR model, the lower break point was identified at infarct size = 8 % and the upper one at 45 %. Using a rigorous statistical approach, it is possible to demonstrate that below a threshold of 8 % the infarct size apparently does not affect the LVEF and therefore a safety threshold could be set at this value. Furthermore, the same analysis suggests that the relationship between infarct size and LVEF impairment is lost for an infarct size > 45 %.

  15. Magazine Influence on Cartridge Case Ejection Patterns with Glock Pistols.

    Science.gov (United States)

    Kerkhoff, Wim; Alberink, Ivo; Mattijssen, Erwin J A T

    2018-01-01

    In this study, the cartridge case ejection patterns of six different Glock model pistols (one specimen per model) were compared under three conditions: firing with a loaded magazine, an empty magazine, and without magazine. The distances, covered by the ejected cartridge cases given these three conditions, were compared for each of the six models. A significant difference was found between the groups of data for each of the tested specimens. This indicates that it is important that, to reconstruct a shooting scene incident based on the ejection patterns of a pistol, test shots are fired with the same pistol type and under the correct magazine condition. © 2017 American Academy of Forensic Sciences.

  16. Association of myocardial inotropic reserve and adrenergic nerve alterations in idiopathic dilated cardiomyopathy. A dobutamine stress echocardiographic and 123-I-MIBG scintigraphic study

    International Nuclear Information System (INIS)

    Prassopoulos, V.P.; Koukouraki, S.; Velidaki, A.; Karkavitsas, N.; Parthenakis, F.; Patrianakos, A.; Kochiadakis, G.; Papadimitriou, E.; Vardas, P.

    2002-01-01

    Aim: Evaluation of contractile reserve is important in congestive hear failure. The aim of this study was to examine the relationship between the myocardial response to dobutamine by stress echocardiography and the sympathetic nerve alterations by 123-I-Metaiodobenzylguanidine (MIBG)scintigraphy and how both contribute to predict exercise capacity in patients with idiopathic dilated cardiomyopathy. Materials-Methods: We studied 20 patients with idiopathic dilated cardiomyopathy (IDC) and ejection fraction < 45% (M/F 13/7, age 56±11 years) while 15 healthy individuals served as controls. Echocardiography and myocardial scintigraphic study with 123-I- MIBG, provided quantitative assessment of left ventricular (LV) wall motion and heart to mediastinum uptake(H/M) ratio and washout. All patients underwent a cardiopulmonary exercise test with a modified Naughton protocol and gas exchange data were analyzed. According to LV response to dobutamine, patients were divided into two groups: those in whom contractility improved in ≥ five segments (Group I: 11 patients) and those in whom contractility improved in < 5 segments (Group II : 9 patients). Results: MIBG uptake was significantly lower in patients than in controls (p < 0.001). MIBG uptake and washout was higher in Group I compared to Group II (P<0,01 and p<0,05). Late MIBG H/M was correlated with resting ejection fraction (r=0,70), wall motion score index (WMSI) (r=-0,50), end systolic wall stress (r=-0,61), washout (r=-0,57), and oxygen consumption at peak exercise (r=0,64) and at anaerobic threshold (r=0,67). LV ejection fraction increased in both groups at Dobutamine, with a higher increase in Group I (p=0,008). WMSI changes at dobutamine correlated significantly with resting ejection fraction (r=0,46) early (r=0,53) and late (r=0,54) MIBG. Multivariate analysis revealed that only the late MIBG uptake was independently associated with the improvement in WMSI. Conclusions: The present data indicate that in

  17. Reconstructing the Morphology of an Evolving Coronal Mass Ejection

    Science.gov (United States)

    2009-01-01

    694, 707 Wood, B. E., Howard, R. A ., Thernisien, A ., Plunkett, S. P., & Socker, D. G. 2009b, Sol. Phys., 259, 163 Wood, B. E., Karovska , M., Chen, J...Reconstructing the Morphology of an Evolving Coronal Mass Ejection B. E. Wood, R. A . Howard, D. G. Socker Naval Research Laboratory, Space Science...mission, we empirically reconstruct the time-dependent three-dimensional morphology of a coronal mass ejection (CME) from 2008 June 1, which exhibits

  18. A study on interaction of DNA molecules and carbon nanotubes for an effective ejection of the molecules

    International Nuclear Information System (INIS)

    Wu, N.; Wang, Q.

    2012-01-01

    The ejection of DNA molecules from carbon nanotubes is reported from interaction energy perspectives by molecular dynamics simulations. The critical ejection energy, which is to be applied to a DNA molecule for a successful ejection from a carbon nanotube, is investigated based on a study on the friction and binding energy between the DNA molecule and the tube. An effective ejection is realized by subjecting a kinetic energy on the DNA molecule that is larger than the solved critical ejection energy. In addition, the relationship between ejection energies and sizes of DNA molecules and carbon nanotubes is investigated. -- Highlights: ► Report the ejection of DNA molecules from CNTs from interaction energy perspectives. ► Develop a methodology for the critical energy of an effective ejection of a DNA molecule from a CNT. ► Present the relationship between critical ejection energies and sizes of DNA molecules and CNTs. ► Provide a general guidance on the ejection of encapsulated molecules from CNTs.

  19. Endothelial Function as a Possible Significant Determinant of Cardiac Function during Exercise in Patients with Structural Heart Disease

    Directory of Open Access Journals (Sweden)

    Bonpei Takase

    2009-01-01

    Full Text Available This study was investigated the role that endothelial function and systemic vascular resistance (SVR play in determining cardiac function reserve during exercise by a new ambulatory radionuclide monitoring system (VEST in patients with heart disease. The study population consisted of 32 patients. The patients had cardiopulmonary stress testing using the treadmill Ramp protocol and the VEST. The anaerobic threshold (AT was autodetermined using the V-slope method. The SVR was calculated by determining the mean blood pressure/cardiac output. Flow-mediated vasodilation (FMD was measured in the brachial artery to evaluate endotheilial function. FMD and the percent change f'rom rest to AT in SVR correlated with those from rest to AT in ejection fraction and peak ejection ratio by VEST, respectively. Our findings suggest that FMD in the brachial artery and the SVR determined by VEST in patients with heart disease can possibly reflect cardiac function reserve during aerobic exercise.

  20. Sizes and locations of coronal mass ejections - SMM observations from 1980 and 1984-1989

    Science.gov (United States)

    Hundhausen, A. J.

    1993-01-01

    A statistical description of the sizes and locations of 1209 mass ejections observed with the SMM coronagraph/polarimeter in 1980 and 1984-1989 is presented. The average width of the coronal mass ejections detected with this instrument was close to 40 deg in angle for the entire period of SMM observations. No evidence was found for a significant change in mass ejection widths as reported by Howard et al. (1986). There is clear evidence for changes in the latitude distribution of mass ejections over this epoch. Mass ejections occurred over a much wider range of latitudes at the times of high solar activity (1980 and 1989) than at times of low activity (1985-1986).