WorldWideScience

Sample records for response moderne mr-verfahren

  1. Functional MRI procedures in the diagnosis of brain tumors. Perfusion- and diffusion-weighted imaging; Funktionelle MR-Verfahren in der Diagnostik intraaxialer Hirntumoren. Perfusions- und Diffusions-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M. [Universitaetsklinikum Heidelberg (Germany). Neurologische Klinik, Abteilung Neuroradiologie; Heiland, S.; Sartor, K.

    2002-08-01

    Despite the increased diagnostic accuracy of contrast material enhanced MR imaging, specification and grading of brain tumors are still only approximate at best: neither morphology, nor relaxation times or contrast material enhancement reliably predict tumor histology or tumor grade. As histology and tumor grade strongly influence which therapy concept is chosen, a more precise diagnosis is mandatory. With diffusion- and perfusion-weighted MR imaging (DWI, PWI) it is now possible to obtain important information regarding the cellular matrix and the relative regional cerebral blood volume (rrCBV) of brain tumors, which cannot be obtained with standard MR techniques. These dynamic-functional imaging techniques are very useful in the preoperative diagnosis of gliomas, lymphomas, and metastases, as well as in the differentiation of these neoplastic lesions from abscesses, atypical ischemic infarctions, and tumor-like manifestations of demyelinating disease. Additionally, they appear suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy and therapy. After therapy these techniques are helpful to better assess the tumor response to therapy, possible therapy failure and therapy complications such as radiation necrosis. (orig.) [German] Die radiologische Diagnostik intraaxialer Hirntumoren ist durch die Magnetresonanztomographie (MRT) erheblich verbessert worden, besonders nach Einfuehrung der paramagnetischen Kontrastmittel. Mit konventionellen MR-Verfahren ist aber noch keine verlaessliche Unterscheidung zwischen Gliomen, Metastasen, primaeren Lymphomen und tumorsimulierenden entzuendlichen Erkrankungen moeglich. In dieser Hinsicht vielversprechend sind neue, funktionell-dynamische MR-Verfahren, mit denen sich nicht-invasiv die zerebrale Wasserdiffusion und Mikrozirkulation erfassen lassen und die eine bessere Gewebecharakterisierung erlauben als die herkoemmlichen MR-Methoden. Die Perfusions-MRT erfasst

  2. MR spectroscopy in dementia; MR-Spektroskopie bei Demenz

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, T.; Gerigk, L.; Giesel, F.; Schuster, L.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung E010, Radiologie, Heidelberg (Germany)

    2010-09-15

    With an increasingly aging population we are faced with the problem of an increasing number of dementia patients. In addition to clinical, neuropsychological and laboratory procedures, MRI plays an important role in the early diagnosis of dementia. In addition to various morphological changes functional changes can also help in the diagnosis and differential diagnosis of dementia. Overall the diagnosis of dementia can be improved by using parameters from MR spectroscopy. This article focuses on MR spectroscopic changes in the physiological aging process as well as on changes in mild cognitive impairment a precursor of Alzheimer's dementia, in Alzheimer's dementia, frontotemporal dementia, vascular dementia and Lewy body dementia. (orig.) [German] Angesichts einer immer aelter werdenden Bevoelkerung sind wir mit dem Problem einer zunehmenden Zahl an Demenzerkrankungen konfrontiert. Neben klinischen, neuropsychologischen und laborchemischen Verfahren spielt die MRT zur Fruehdiagnostik einer Demenz eine wichtige Rolle. Morphologische Veraenderungen wie auch verschiedene funktionelle Verfahren helfen bei der Diagnostik und Differenzialdiagnostik einer Demenz. Insgesamt kann mittels MR-spektroskopischer Parameter die Diagnostik einer Demenz verbessert werden. In diesem Artikel soll auf MR-spektroskopische Veraenderungen im Rahmen des physiologischen Alterungsprozesses eingegangen werden. Ferner werden speziell Veraenderungen bei leichter kognitiver Beeintraechtigung, einer Vorform der Alzheimer-Demenz, bei Alzheimer-, frontotemporaler, vaskulaerer und Lewy-Koerper-Demenz eroertert. (orig.)

  3. MR imaging of the kidneys: new diagnostic strategies; MR-Bildgebung der Nieren. Neue Ansaetze in der Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, S.O.; Knopp, M.V.; Bock, M.; Floemer, F.; Essig, M.; Hawighorst, H.; Kaick, G. van [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik; Kallinowski, F. [Heidelberg Univ. (Germany). Chirurgische Universitaetsklinik; Just, A. [Heidelberg Univ. (Germany). 1. Physiologisches Inst.; Laub, G. [Siemens AG, Erlangen (Germany). Unternehmensbereich Medizinische Technik; Prince, M.R [Michigan Univ., Ann Arbor, MI (United States). Dept. of Radiology

    1999-05-01

    Aim: New diagnostic strategies for evaluation of the kidney by fast MR imaging of renal morphology, multiphase 3D gadolinium MR angiography, MR urography and MR flow measurements. A signal MR examination is designed to grade renovascular disease and assess the hemodynamic and functional significance, detect and characterize renal lesions and evaluate the urinary tract. Results: The combined analysis of morphologic and functional data allows reliable assessment of renal artery stenosis, benign and malignant renal masses and diseases of the renal collecting system and ureters, as well as congenital abnormalities in good agreement to the results of conventional imaging modalities. The improved tissue contrast and additional functional information compensates for the disadvantage of a lower spatial resolution. Conclusion: Combined morphologic and functional MR examination represents a reliable, non-invasive and cost-effective alternative imaging modality for comprehensive diagnostic evaluation of renal disease. (orig.) [Deutsch] Fragestellung: Darstellung neuer diagnostischer Moeglichkeiten im Bereich der Niere mittels schneller Magnetresonanz (MR)-Bildgebung. Methodik: Vorgestellt wird ein kombiniertes morphologisches und funktionelles Untersuchungskonzept bestehend aus schneller morphologischer Bildgebung, multiphasischer 3D-Gadolinium-MR-Angiographie, MR-Urographie und MR-Flussmessung. In einer einzigen MR-Untersuchung sollen vaskulaere Erkrankungen erfasst, eingestuft und auf ihre haemodynamische und funktionelle Signifikanz ueberprueft werden, renale Laesionen detektiert und differenziert sowie die Harnabflusswege beurteilt werden. Ergebnisse: Durch Integration der gewonnenen morphologischen und funktionellen Daten lassen sich Nierenarterienstenosen, benigne und maligne renale Tumoren, Harnabflussstoerungen und kongenitale Fehlbildungen mit aehnlicher Genauigkeit wie in den konventionellen radiologischen Verfahren erfassen. Der Nachteil der geringeren raeumlichen

  4. The Siemens pyrolysis-combustion process; Das Siemens Schwel-Brenn-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, D [Siemens - KWU, Offenbach (Germany)

    1997-12-31

    The market introduction fo the SIEMENS pyrolysis-combustion process is a technical and ecological milestone in thermal waste processing. It bridges the gap between conventional incineration and recycling and is ideally suited for the modern waste management philosophy. The innovative combination of pyrolysis followed by high-temperature combustion produces energy and reusable materials nearly without emissions. (orig/sr) [Deutsch] Die Markteinfuehrung des Schwel-Brenn-Verfahrens hat im Bereich der thermischen Muellentsorgung eine technologische und oekologische Zeitenwende eingeleitet. Es fuegt sich als Bruecke zwischen herkoemmlicher Muellverbrennung und stofflichem Muell-Recyling ideal in das Konzept einer oekologischen Kreislaufwirtschaft. Die innovative Kombination von Muellverschwelung (Pyrolyse) und anschliessender Hochtemperaturverbrennung wandelt den unvermeidbaren Restmuell nahezu rueckstandsfrei in Wertstoffe und Energie um. (orig/SR)

  5. The Siemens pyrolysis-combustion process; Das Siemens Schwel-Brenn-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, D. [Siemens - KWU, Offenbach (Germany)

    1996-12-31

    The market introduction fo the SIEMENS pyrolysis-combustion process is a technical and ecological milestone in thermal waste processing. It bridges the gap between conventional incineration and recycling and is ideally suited for the modern waste management philosophy. The innovative combination of pyrolysis followed by high-temperature combustion produces energy and reusable materials nearly without emissions. (orig/sr) [Deutsch] Die Markteinfuehrung des Schwel-Brenn-Verfahrens hat im Bereich der thermischen Muellentsorgung eine technologische und oekologische Zeitenwende eingeleitet. Es fuegt sich als Bruecke zwischen herkoemmlicher Muellverbrennung und stofflichem Muell-Recyling ideal in das Konzept einer oekologischen Kreislaufwirtschaft. Die innovative Kombination von Muellverschwelung (Pyrolyse) und anschliessender Hochtemperaturverbrennung wandelt den unvermeidbaren Restmuell nahezu rueckstandsfrei in Wertstoffe und Energie um. (orig/SR)

  6. Ebenen des Verstehens: Überlegungen zu einem Verfahren zum Wurzelziehen

    Science.gov (United States)

    Winter, Martin

    Wir bemühen uns, insbesondere bei Kindern, den Lernprozess auch im Mathematikunterricht durch den Einsatz von Materialien zu unterstützen. Die Arbeitsschritte dienen dabei oft der Vorbereitung oder Herleitung von Verfahren - in der Hoffnung, dass durch die Veranschaulichung Zusammenhänge besser verstanden werden. Worin dann das Verstehen besteht, wenn im Ergebnis ein Verfahren von den Kindern erfolgreich abgearbeitet wird, ist nicht unmittelbar zu sehen.

  7. Sogenannte projektive Techniken: Verfahren zwischen Psychometrie, Hermeneutik und qualitativer Heuristik

    OpenAIRE

    Schaipp, Christian; Plaum, Ernst

    2000-01-01

    Bezüglich der diagnostischen Tauglichkeit projektiver Verfahren existiert auf internationaler Ebene ein seit langem anhaltender Grundsatzstreit. In diesem Kontext wird deutlich gemacht, dass eine zweckmäßige Einordnung und ein angemessenes Verständnis projektiver Techniken erheblich erleichtert wird, wenn man drei wissenschaftstheoretische und methodologische Strömungen (Psychometrie, Hermeneutik, qualitative Heuristik) unterscheidet. Es wird dafür plädiert, derartige Verfahren vor allem in e...

  8. Modern magnetic resonance imaging of the liver; Modernes MR-Protokoll fuer die Leberbildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hedderich, D.M.; Maintz, D.; Persigehl, T. [Universitaetsklinikum Koeln, Institut fuer Diagnostische und Interventionelle Radiologie, Koeln (Germany); Weiss, K. [Universitaetsklinikum Koeln, Institut fuer Diagnostische und Interventionelle Radiologie, Koeln (Germany); Philips Healthcare Deutschland, Hamburg (Germany)

    2015-12-15

    Magnetic resonance imaging (MRI) of the liver has become an essential tool in the radiological diagnostics of both focal and diffuse diseases of the liver and is subject to constant change due to technological progress. Recently, important improvements could be achieved by innovations regarding MR hardware, sequences and postprocessing methods. The diagnostic spectrum of MRI could be broadened particularly due to new examination sequences, while at the same time scanning time could be shortened and image quality has been improved. The aim of this article is to explain both the technological background and the clinical application of recent MR sequence developments and to present the scope of a modern MRI protocol for the liver. (orig.) [German] Die Magnetresonanztomographie (MRT) der Leber ist in der radiologischen Diagnostik fokaler und diffuser Lebererkrankungen fest etabliert und untersteht einem steten Wandel durch den fortwaehrenden technischen Fortschritt. Durch Neuerungen bei der Hardware, den Sequenzen und der Bildnachverarbeitung konnten in den letzten Jahren deutliche Fortschritte erzielt werden. Insbesondere auf dem Gebiet der Untersuchungssequenzen kam es zu Entwicklungen, die das diagnostische Spektrum der MRT erweiterten, zu einer Verkuerzung der Scanzeit fuehrten und zu einer Verbesserung der Bildqualitaet beitrugen. Gegenstand dieses Artikels ist es, den technischen Hintergrund und die klinische Anwendung neuerer Sequenztechniken zu erklaeren und so die Moeglichkeiten und den Umfang eines modernen MRT-Untersuchungsprotokolls fuer die Leber darzustellen. (orig.)

  9. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    wiederholte Untersuchungen durchlaufen muessen, und paediatrische Patienten relevant ist. Dabei koennen jedoch die Erfahrungen, die im Verlauf der letzten Jahre mit der Hybridtechnologie PET-CT gewonnen wurden, nicht direkt auf die MR-PET uebertragen werden. Ein wesentliches Beispiel hierfuer ist die Schwaechungskorrektur, fuer die in der PET-CT die mittels CT bestimmten Hounsfield-Einheiten verwendet werden. Da die in der PET emittierten 511-keV-Photonen durch das Koerpergewebe des Patienten geschwaecht werden, werden die CT-Datensaetze in sog. lineare Schwaechungskoeffizienten (''linear attenuation coefficients'', LAC) konvertiert. Da die Bilddatenakquisition in der MRT nicht auf einer Schwaechung von Roentgenstrahlung, sondern einer Messung der Protonendichte und von gewebespezifischen Relaxationszeiten basiert, muessen in der MR-PET alternative Verfahren zur Schwaechungskorrektur eingesetzt werden. Darueber hinaus bietet die MRT auch alternative Sequenz- und Akquisitionstechnologien, die es erlauben, bisherige Limitationen z. B. bzgl. der Bewegungskorrektur zu adressieren. Dieser Artikel berichtet ueber initiale klinische Erfahrungen mit einem voll integrierten MR-PET-System, wobei MR-Techniken zur Korrektur von Bewegungsartefakten, die Schwaechungskorrektur und die Reduktion von Metallartefakten im Zentrum stehen. (orig.)

  10. Narrative Kompetenz: Anforderungen an ein Verfahren der Sprach-standsfeststellung im Elementarbereich

    Directory of Open Access Journals (Sweden)

    Natalia Kapica

    2014-10-01

    Full Text Available Im vorliegenden Beitrag wird der Frage nachgegangen, welche Merkmale ein Verfahren zur Feststellung des Sprachstandes im Bereich Erzählkompetenz vereinen sollte, um nutzbare Informationen für die Planung an-schließender Fördermaßnahmen zu liefern. Dabei wird von der spracherwerbstheoretisch hergeleiteten Annahme ausgegangen, dass Förderangebote entwicklungssensitiv angelegt sein sollten, also von der erwartbaren Erwerbsprogression und dem jeweiligen Sprachstand des Kindes ausgehen sollten. Mit dieser diagnostischen Zielsetzung vor Augen werden anhand der Kategorien „entwicklungspsychologische/schulische Relevanz“, „profilanalytische Auswertung“ sowie „Authentizität der Sprachdaten“ Anforderungen an ein förderdiagnostisches Verfahren formuliert und exemplarisch auf Erkenntnisse der Spracherwerbsforschung zurückbezogen. The present article addresses the question of which characteristics a language proficiency assessment of children ́s narrative competence should possess to allow for its results to be used for planning subsequent assistance measures.The underlying assumption states that language acquisition processes follow their own inherent developmental pathway. Language promotion programmes should therefore be responsive to the children's development and be based on the respective proficiency level and the learning progress that may be expected. In view of this objective, the article specifies requirements on „interventional diagnostics” and correlates these with insights from languageacquisition research.

  11. Verfahren zur genbasierten Diagnose eines Legasthenierisikos

    OpenAIRE

    Wilcke, Arndt; Ahnert, Peter; Kirsten, Holger; Ligges, Carolin; Boltze, Johannes

    2016-01-01

    Die vorliegende Erfindung betrifft ein Verfahren zur Diagnose eines Legasthenierisikos, umfassend die Schritte: a) Bereitstellung einer Nukleinsäure beinhaltenden Probe von einem zu diagnostizierenden Menschen, b) Bestimmung des Genotyps der Nukleinsäure der Probe für mindestens eine chromosomale Region, ausgewählt aus der Gruppe bestehend aus der Region von Nukleotid 12091000 bis 12200000 des Chromosoms 1, der Region von Nukleotid 89066000 bis 89088000 des Chromosoms 15, der Region von Nukle...

  12. Questionnaire responses concerning safety issues in MR examination

    International Nuclear Information System (INIS)

    Yamaguchi-Sekino, Sachiko; Nakai, Toshiharu; Muranaka, Hiroyuki

    2011-01-01

    Recently, the rising numbers of medical implants and scanners with higher static magnetic field have increased safety concerns for magnetic resonance (MR) examination. To determine future safety focus, we distributed anonymous questionnaires to 3250 members of the Japanese Society for Magnetic Resonance in Medicine (JSMRM) and received 978 responses. Safety issues on the questionnaire concentrated on the handling of patients with implants (Q7-18, appendix), acoustic trauma due to scanning (Q19-21, appendix), and MR compatibility within the scanner room (Q22-25, appendix). Ninety-three percent of respondents indicated they had encountered cases with implants or medical materials of unknown MR compatibility; 21.7% reported heating problems and 15.0%, nerve stimulation problems, in patients with implants during MR examination. Although 88.7% of respondents recognized the term ''MR compatibility'', 68.2% indicated limited detailed understanding of the term. Eleven percent had had cases with suspected acoustic injury from MR scanner noise. Scanner noise levels were not clarified in any way in 37.4% cases, but 69.5% applied ear protection to patients. Labeling of ''MR compatibility'' of equipment brought into the MR scanner room was reported by 71.9%. More than 50% experienced MR compatibility issues related to equipment brought into the MR scanner room. With regard to safety issues on metallic objects which are implanted in MR workers, 88.1% indicated they would continue current operations even the implant is inside the body. Respondents identified lectures and seminars by professional societies, safety training by manufacturers, and information from the Internet and literature as the 3 main sources for up-dating safety information for MR examination. (author)

  13. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  14. Diagnostic criteria in MR neurography; Diagnostische Kriterien in der MR-Neurographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, P. [Deutsches Krebsforschungszentrum, Allgemeinradiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany)

    2017-03-15

    Peripheral neuropathies are frequent and can mostly be correctly diagnosed by clinical examination and electrophysiology; however, diagnostically difficult cases are sometimes encountered especially with respect to precise localization of nerve lesions. Imaging of the peripheral nervous system has been shown to provide additional useful diagnostic information. In addition to the more widely available nerve sonography, magnetic resonance neurography (MRN) is the method of choice in diagnostically complex cases. The most important pulse sequence is a T2-weighted fat-saturated pulse sequence with high in-plane resolution and detects increased T2-weighted signals of nerve fascicles as a highly sensitive sign for nerve lesions. Further established diagnostic criteria are nerve caliber and, less commonly used, contrast agent uptake. The spatial pattern of nerve lesions aids in the diagnostic classification of neuropathies. Functional imaging techniques, such as diffusion tensor imaging (DTI) and nerve perfusion are currently under examination with respect to the clinical potential. If all other diagnostic methods, including clinical examination, electrophysiology and nerve sonography do not arrive at an unambiguous diagnosis of a peripheral neuropathy, MRN should be used. The special value of MRN is demonstrated particularly in complex nerve lesions, such as traumatic plexopathies and in partial fascicular neuropathies and many other indications. (orig.) [German] Periphere Neuropathien sind haeufig und meist gut mithilfe klinischer Untersuchung und Elektrophysiologie zu diagnostizieren. Immer wieder gibt es jedoch diagnostisch schwierige Faelle, insbesondere auch hinsichtlich der praezisen Lokalisation von Nervenlaesionen. Die Etablierung bildgebender Verfahren auch fuer das periphere Nervensystem hat sich als hilfreiche zusaetzliche Diagnostik erwiesen. Neben der breiter verfuegbaren Nervensonographie ist die MR-Neurographie (MRN) Methode der Wahl bei der Diagnostik

  15. Material-stream-specific waste treatment with particular regard to thermal processes; Stoffstromspezifische Abfallbehandlung im Hinblick auf thermische Verfahren. Fachseminar

    Energy Technology Data Exchange (ETDEWEB)

    1998-09-01

    The experts` seminar on ``Material-stream-specific waste treatment with particular regard to thermal processes`` is the third event of its kind to be held by the Zentrum fuer Abfallforschung (ZAF=Centre for Waste Research). The purpose of the seminar is to de-emotionalise the debate going on between environment-oriented citizens, authorities, scientists, operators, and manufacturers and to find solutions that are acceptable in terms of costs as well as environmental impact. The seminar deals with traditional methods such as grate firing as well as with new methods such as low-temperature carbonisation, thermoselect, Noell-KRC, or RCP processes. [Deutsch] Das Fachseminar `Stoffstromspezifische Abfallbehandlung im Hinblick auf thermische Verfahren` ist die 13. Veranstaltung dieser Art, die durch das Zentrum fuer Abfallforschung (ZAF) durchgefuehrt wird. Das Seminar soll dazu beitragen, die Diskussion zwischen umweltbewuessten Bevoelkerungsgruppen, Behoerden, Wissenschaft, Betreibern und Herstellern zu versachlichen und dabei Loesungen zu finden, die hinsichtlich der Kosten und der Umweltbeeintraechtigung vertretbar sind. Es werden sowohl die traditionellen Verfahren wie Rostfeuerung als auch neue Verfahren wie Schwelbrenn-, Thermoselekt-, Noell-KRC- oder RCP-Verfahren behandelt. (orig.)

  16. Methods of heat transformation for solar facilities in buildings; Verfahren der Waermetransformation fuer die solare Gebaeudetechnik

    Energy Technology Data Exchange (ETDEWEB)

    Henning, H.M. [Fraunhofer-Inst. fuer Solare Energiesysteme, Freiburg (Germany). Gruppe Aktive Thermische Systeme; Treffinger, P. [Deutsche Zentrum fuer Luft- und Raumfahrt (DLR), Lampoldshausen (Germany). Inst. fuer Technische Thermodynamik

    1998-02-01

    Processes in which a heat pump cycle is driven by thermal energy may be defined as heat transformation processes. The technical realization of this type of processes in general is based on sorption techniques. Depending on the temperature level of the utilized heat these technologies may be used for either cooling or heating of buildings. The paper presents state-of-the-art technologies and new developments. It comprises solar cooling of buildings, utilization of environmental energy sources (earth, air) by thermal driven heat pumps and seasonal storage of solar thermal energy by means of sorption processes. (orig.) [Deutsch] Unter Waermetransformationsverfahren werden im allgemeinen Verfahren verstanden, in denen ein Waermepumpenprozess mit thermischer Energie angetrieben wird. Die technische Realisierung dieser Verfahren erfolgt ueberwiegend mit Hilfe von Sorptionsvorgaengen. Abhaengig vom Temperaturniveau des Nutzwaermestroms koennen solche Verfahren im Gebaeudebereich fuer die Kuehlung oder Heizung eingesetzt werden. Im Beitrag werden der Stand der Technik sowie neue Entwicklungen vorgestellt. Im einzelnen umfasst der Beitrag die solare Kuehlung von Gebaeuden, die Nutzung von Umweltenergie (Erdreich, Luft) mittels thermisch angetriebener Waermepumpen sowie die saisonale Speicherung von Solarenergie ueber Sorptionsprozesse. (orig.)

  17. Influence of age and menstrual cycle on mammography and MR imaging of the breast; Einfluss von Alter und Menstruationszyklus auf Mammographie und MR-Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Schimpfle, M.; Ohmenhaeuser, K.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik

    1997-09-01

    Implikationen fuer Durchfuehrung und Befundung von konventioneller Mammographie und MR-Mammographie ergeben. Die Kenntnisse dieser Veraenderungen sind darueber hinaus hilfreich fuer die Interpretation erhobener Befunde im Methodenvergleich. Schliesslich ermoeglichen die mittels bildgebender Verfahren gewonnenen Daten wichtige grundsaetzliche Einblicke in die Physiologie und Pathophysiologie der Mamma in vivo. (orig.)

  18. MR-guided focused ultrasound. Current and future applications; MR-gesteuerter fokussierter Ultraschall. Aktuelle und potenzielle Indikationen

    Energy Technology Data Exchange (ETDEWEB)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen-Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Napoli, A. [Sapienza Universitaet Rom, Abteilung fuer Radiologie (Department of Radiological Sciences), MRgFUS and Cardiovascular Imaging Unit, Rom (Italy); Matzko, M. [Klinikum Dachau, Abteilung fuer diagnostische und interventionelle Radiologie, Dachau (Germany)

    2013-03-15

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [German] MRT-gesteuerter hochintensiver fokussierter Ultraschall (MRgFUS bzw. MR-HIFU) ist ein nichtinvasives Verfahren zur praezisen Thermoablation eines Zielgewebes. Bei dieser Methode werden benachbarte Gewebe und Organe geschont. Die Kombination des fokussierten Ultraschalls (FUS) mit der MRT zwecks Planung und Monitoring (nahezu) in Echtzeit sowie zur Erfolgskontrolle von Behandlungen traegt wesentlich zur Sicherheit dieser Methode bei. MRgFUS ist klinisch v. a. zur Behandlung von symptomatischen Uterusmyomen etabliert, gefolgt von der palliativen Ablation von Knochenmetastasen. Weitere vielversprechende Anwendungsgebiete des MRgFUS sind die Adenomyose des Uterus, die Behandlung von Prostata-, Mamma- und Lebertumoren sowie der intrakranielle Einsatz. (orig.)

  19. Modern cartilage imaging of the ankle; Moderne Knorpelbildgebung des Sprunggelenks

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph [University Hospital Heidelberg (Germany). Diagnostic and Interventional Radiology; Jungmann, Pia M. [Technical Univ. Munich (Germany). Radiology; Kuni, Benita [Ortho-Zentrum Karlsruhe (Germany). Orthopedics and Trauma Surgery

    2017-10-15

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  20. Functional MR imaging of the liver; Funktionelle MR-Tomographie der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Wibmer, A.; Nolz, R.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Allgemeines Krankenhaus der Stadt Wien, Universitaetsklinik fuer Radiodiagnostik und Nuklearmedizin, Wien (Austria); Trauner, M. [Medizinische Universitaet Wien, Universitaetsklinik fuer Innere Medizin III, Klinische Abteilung fuer Gastroenterologie und Hepatologie, Wien (Austria)

    2015-12-15

    The diagnostics of diffuse liver disease traditionally rely on liver biopsies and histopathological analysis of tissue specimens. However, a liver biopsy is invasive and carries some non-negligible risks, especially for patients with decreased liver function and those requiring repeated follow-up examinations. Over the last decades, magnetic resonance imaging (MRI) has developed into a valuable tool for the non-invasive characterization of focal liver lesions and diseases of the bile ducts. Recently, several MRI methods have been developed and clinically evaluated that also allow the diagnostics and staging of diffuse liver diseases, e. g. non-alcoholic fatty liver disease, hepatitis, hepatic fibrosis, liver cirrhosis, hemochromatosis and hemosiderosis. The sequelae of diffuse liver diseases, such as a decreased liver functional reserve or portal hypertension, can also be detected and quantified by modern MRI methods. This article provides the reader with the basic principles of functional MRI of the liver and discusses the importance in a clinical context. (orig.) [German] Die Diagnostik diffuser Lebererkrankungen stuetzt sich klassisch auf die Leberbiopsie und deren histopathologische Analyse. Dieses Verfahren ist allerdings fuer die Patienten unangenehm und schmerzhaft, birgt v. a. bei Patienten mit Lebererkrankungen ein gewisses Risiko und eignet sich daher nur sehr eingeschraenkt zur Verlaufskontrolle bei chronischen Erkrankungen. Die Magnetresonanztomographie (MRT) der Leber nimmt schon jetzt eine zentrale Stellung in der Diagnostik von Raumforderungen der Leber und von Erkrankungen der Gallenwege ein. Darueber hinaus bietet dieses nichtinvasive Verfahren Moeglichkeiten, diffuse Erkrankungen des Leberparenchyms zu diagnostizieren und ihren Schweregrad abzuschaetzen, z. B. bei nichtalkoholischer Leberverfettung, Hepatitis, Leberfibrose, Zirrhose, Haemochromatose und Siderose und anderen. Folgen einer parenchymatoesen Lebererkrankung, wie die portale

  1. Von Roll RCP method - first experiences; Von Roll RCP - Verfahren. Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Capitaine, P.; Engweiler, J. [Roll Umwelttechnik AG, Zuerich (Switzerland)

    1998-09-01

    The RCP method was designed as a residue-optimised alternative to the thermally optimised grate firing of residual wastes. Its technical realisation and development to market maturity took no more than 5 years. In the first process stage the waste is converted to high-carbon pyrolysis charcoal and high-rank gas in the absence of oxygen. In the second stage these substances are oxidised by addition of oxygen. The resulting temperature causes the non-combustible constituents of the slag to melt. In a third, optional, stage this molten slag can be liberated of (heavy) metals to such an extent that it can subsequently be used directly as additive for grinding. Further exhaust gas treatment is facilitated by the use of a circulatory fluidised-bed secondary combustion chamber. Despite the reduced flue gas volume and resultant higher pollutant concentrations in the crude gas, overall emissions are lower than in conventional plants. [Deutsch] Das reststoffoptimierte RCP Verfahren ist als Alternative zur thermisch optimierten Rostverbrennung von Restabfaellen konzipiert. In nur fuenf Jahren wurde das Verfahren technisch umgesetzt und zur Marktreife entwickelt. In einer ersten Stufe des Verfahrens wird der Abfall unter Luftabschluss in einen kohlenstoffreichen Pyrolysekoks und eine heizwertreiches Gas umgesetzt. Im zweiten Schritt werden diese Stoffe unter Zugabe von Sauerstoff oxidiert. Dabei treten Temperaturen auf, bei denen die nichtbrennbaren Bestandteile der Schlacke schmelzen. Optional wird diese Schmelzschlacke in einem dritten Schritt derart von (Schwer-) Metallen befreit, dass sie anschliessend direkt als Zement-Zumahlstoff eingesetzt werden kann. Die Nutzung der zirkulierenden Wirbelschicht - Nachbrennkammer zur Abgasbehandlung vereinfacht die weitergehende Abgasbehandlung. Trotz verringertem Rauchgasvolumen und damit hoeheren Schadstoffkonzentrationen im Rohgas werden die Gesamtemissionen gegenueber konventionellen Anlagen verringert. (orig./SR)

  2. The Pyromelt process; Das Pyromelt-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Redepenning, H; Kremer, H; Rizzon, H [ML Entsorgungs- und Energieanlagen GmbH, Ratingen (Germany)

    1997-12-31

    PyroMelt is a thermal process for waste treatment by pyrolysis followed by a melting stage. The pyrolysis process produces the more or less homogeneous products pyrolysis gas, oil, and coke. In the melting stage, the inorganic constituents of the waste materials are converted into an eluation-resistant, recyclable granulated slag, while the organic constitutents are combusted completely without residues. (orig) [Deutsch] PyroMelt ist ein thermisches Verfahren zur Behandlung von Abfaellen durch eine Kombination aus Pyrolyse mit einer nachgeschalteten Einschmelzung. Die Pyrolyse uebernimmt die Aufgabe der thermischen Vorbehandlung der Abfaelle in die vergleichsweise homogenen Produkte Pyrolysegas, -oel und -koks. In der Einschmelzung werden die anorganischen Bestandteile der Abfaelle in eine eluationsresistentes und verwertbares Schlackegranulat ueberfuehrt. Gleichzeitig werden die organischen Abfallbestandteile vollstaendig ausgebrannt. (orig)

  3. The Pyromelt process; Das Pyromelt-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Redepenning, H.; Kremer, H.; Rizzon, H. [ML Entsorgungs- und Energieanlagen GmbH, Ratingen (Germany)

    1996-12-31

    PyroMelt is a thermal process for waste treatment by pyrolysis followed by a melting stage. The pyrolysis process produces the more or less homogeneous products pyrolysis gas, oil, and coke. In the melting stage, the inorganic constituents of the waste materials are converted into an eluation-resistant, recyclable granulated slag, while the organic constitutents are combusted completely without residues. (orig) [Deutsch] PyroMelt ist ein thermisches Verfahren zur Behandlung von Abfaellen durch eine Kombination aus Pyrolyse mit einer nachgeschalteten Einschmelzung. Die Pyrolyse uebernimmt die Aufgabe der thermischen Vorbehandlung der Abfaelle in die vergleichsweise homogenen Produkte Pyrolysegas, -oel und -koks. In der Einschmelzung werden die anorganischen Bestandteile der Abfaelle in eine eluationsresistentes und verwertbares Schlackegranulat ueberfuehrt. Gleichzeitig werden die organischen Abfallbestandteile vollstaendig ausgebrannt. (orig)

  4. MR Imaging in Monitoring and Predicting Treatment Response in Multiple Sclerosis.

    Science.gov (United States)

    Río, Jordi; Auger, Cristina; Rovira, Àlex

    2017-05-01

    MR imaging is the most sensitive tool for identifying lesions in patients with multiple sclerosis (MS). MR imaging has also acquired an essential role in the detection of complications arising from these treatments and in the assessment and prediction of efficacy. In the future, other radiological measures that have shown prognostic value may be incorporated within the models for predicting treatment response. This article examines the role of MR imaging as a prognostic tool in patients with MS and the recommendations that have been proposed in recent years to monitor patients who are treated with disease-modifying drugs. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Modern diagnostics of cystic liver lesions and hemangiomas; Moderne Diagnostik zystischer Leberlaesionen und Haemangiome

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S.; Bastati-Huber, N.; Ba-Ssalamah, A. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Wien (Austria); Brancatelli, G. [Universitaetsklinikum Palermo, Abteilung Radiologie, Palermo (Italy)

    2015-01-01

    Cystic liver lesions incorporate a broad heterogeneous group of mostly benign but also malignant abnormalities. The radiological aim is the non-invasive diagnosis with the use of different imaging modalities to determine the type of lesion. The common generally asymptomatic incidental findings of cystic lesions on ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) must be classified on the basis of specific imaging features. Such a differentiation is essential because the clinical consequences and the appropriate therapy can vary depending on the underlying pathology. Due to the morphological overlap of many cystic lesions, conventional radiological methods are often insufficient. The huge advances in cross-sectional imaging (multidetector CT, MRI with special sequences and different contrast agents and MR cholangiopancreatography) in combination with the clinical history usually enable a non-invasive diagnosis. Pathognomonic morphological and hemodynamic lesion features, as well as a knowledge of the pathomechanisms, help to differentiate this broad spectrum of entities. In this article the different entities of cystic liver lesions, together with the appropriate diagnostic method for detection and distinction and including their strengths and limitations, are demonstrated. A well-founded knowledge about the development of various cystic liver lesions and the suitable choice of imaging method facilitate a non-invasive diagnosis. (orig.) [German] Die zystischen Leberlaesionen umfassen eine grosse heterogene Gruppe meist benigner, jedoch auch maligner Veraenderungen. Das radiologische Ziel ist die nichtinvasive Artdiagnose mithilfe verschiedener bildgebender Verfahren. Die haeufigen, meist asymptomatischen Zufallsbefunde in Ultraschall, CT und MRT muessen anhand spezieller bildgebender Kriterien klassifiziert werden. Eine Differenzierung ist hierbei essenziell, da die klinischen Konsequenzen und weiterfuehrenden Therapien je nach zugrunde

  6. Neoadjuvant chemotherapy for breast cancer: correlation between the baseline MR imaging findings and responses to therapy

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Yuen, Sachiko; Kasami, Masako

    2010-01-01

    To retrospectively evaluate the magnetic resonance (MR) imaging findings of breast cancer before neoadjuvant chemotherapy (NAC) and to compare findings of chemosensitive breast cancer with those of chemoresistant breast cancer. The MR imaging findings before NAC in 120 women undergoing NAC were reviewed. The MR imaging findings were compared with the pathological findings and responses. A complete response (pCR) and marked response were achieved in 12 and 35% of 120 breast cancers in 120 women respectively. Breast cancers with a pCR or marked response were classified as chemosensitive breast cancer. The remaining 64 breast cancers (53%) were classified as chemoresistant breast cancer. Large tumour size, a lesion without mass effect, and very high intratumoural signal intensity on T2-weighted MR images were significantly associated with chemoresistant breast cancer. Lesions with mass effect and washout enhancement pattern were significantly associated with chemosensitive breast cancer. Areas with very high intratumoural signal intensity on T2-weighted images corresponded pathologically to areas of intratumoural necrosis. Several MR imaging features of breast cancer before NAC can help predict the efficacy of NAC. (orig.)

  7. Neoadjuvant chemotherapy for breast cancer: correlation between the baseline MR imaging findings and responses to therapy

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, Takayoshi; Yuen, Sachiko [Shizuoka Cancer Center Hospital, Breast Imaging and Breast Intervention Section, Naga-izumi, Shizuoka (Japan); Kasami, Masako [Shizuoka Cancer Center Hospital, Department of Pathology, Naga-izumi, Shizuoka (Japan)

    2010-10-15

    To retrospectively evaluate the magnetic resonance (MR) imaging findings of breast cancer before neoadjuvant chemotherapy (NAC) and to compare findings of chemosensitive breast cancer with those of chemoresistant breast cancer. The MR imaging findings before NAC in 120 women undergoing NAC were reviewed. The MR imaging findings were compared with the pathological findings and responses. A complete response (pCR) and marked response were achieved in 12 and 35% of 120 breast cancers in 120 women respectively. Breast cancers with a pCR or marked response were classified as chemosensitive breast cancer. The remaining 64 breast cancers (53%) were classified as chemoresistant breast cancer. Large tumour size, a lesion without mass effect, and very high intratumoural signal intensity on T2-weighted MR images were significantly associated with chemoresistant breast cancer. Lesions with mass effect and washout enhancement pattern were significantly associated with chemosensitive breast cancer. Areas with very high intratumoural signal intensity on T2-weighted images corresponded pathologically to areas of intratumoural necrosis. Several MR imaging features of breast cancer before NAC can help predict the efficacy of NAC. (orig.)

  8. Entwicklung eines kontinuierlichen Verfahrens zur enzymkatalysierten Synthese eines strukturierten Triglycerides

    OpenAIRE

    Stadler, Hans-Gerhard

    2005-01-01

    Ausgangspunkt für die in der vorliegenden Arbeit durchgeführten Entwicklung eines kontinuierlichen Verfahrens zur Synthese des strukturierten Triglycerides 1,3-Oleyl-2-palmitoylglycerin war die von Schmid [Schmid 1999] entwickelte lipase-katalysierte Zwei-Schritt-Synthese für strukturierte Triglyceride vom Typ ABA [European Patent Application; EP 0 882 797 A2]. In der ersten Reaktionsstufe dieser zweistufigen Umesterung wird in einer Folgereaktion das Substrat Tripalmitin mit Hilfe ein...

  9. Experimentelle Untersuchung des Chemical Looping Verfahrens an einer 1 MW Versuchsanlage

    OpenAIRE

    Orth, Matthias

    2014-01-01

    Im Zeichen des Klimawandels haben sich führende Industrienationen geeinigt, ihre jeweiligen CO2-Emissionen signifikant zu senken. Diese Reduktionsziele können nur erreicht werden, wenn die Emissionen bei der Energieerzeugung deutlich gesenkt werden. In der vorliegenden Arbeit wird das sogenannte Chemical Looping Verfahren untersucht, bei dem Energie aus fossilen Energieträgern gewonnen und das dabei entstehende CO2 abgeschieden wird. Die aktuelle Forschung im Bereich Chemical Looping konzentr...

  10. Ein Verfahren zur schnellen experimentellen Charakterisierung der Quietschneigung von Kfz-Scheibenbremsen

    OpenAIRE

    Gödecker, Holger

    2015-01-01

    Die Hauptaufgabe der bei dieser Arbeit im Vordergrund stehenden Kfz-Scheibenbremse ist das Verzögern des Fahrzeuges durch den auftretenden Reibeffekt. Dabei kann es zu ungewollten selbsterregten Schwingungen und damit zu störenden Geräuschentwicklungen kommen. Dieses bei der Entwicklung und Konstruktion von Bremsen vorherzusagen und zu vermeiden ist ein großes Thema in Industrie und Forschung. In dieser Arbeit wird ein Verfahren beschrieben, mit dem experimentell schnell, noch vor dem Auft...

  11. Rectal cancer: assessment of complete response to preoperative combined radiation therapy with chemotherapy--conventional MR volumetry versus diffusion-weighted MR imaging.

    Science.gov (United States)

    Curvo-Semedo, Luís; Lambregts, Doenja M J; Maas, Monique; Thywissen, Thomas; Mehsen, Rana T; Lammering, Guido; Beets, Geerard L; Caseiro-Alves, Filipe; Beets-Tan, Regina G H

    2011-09-01

    To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry. A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry. Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements. Post-CRT DW MR

  12. Verfahren zur Hydroformylierung, Liganden mit von Bisphenol A abgeleiteter Struktur und Katalysator umfassend einen Komplex dieser Liganden

    NARCIS (Netherlands)

    2002-01-01

    Die vorliegende Erfindung betrifft ein Verfahren zur Hydroformylierung ethylenisch ungesättigter Verbindungen, wobei man als Hydroformylierungskatalysator wenigstens einen Komplex eines Metalss der VIII. Nebengruppe mit wenigstens einer phosphorhaltigen Verbindung als Liganden einsetzt, wobei diese

  13. Mild cognitive impairment. Diagnostic value of different MR techniques; ''Mild cognitive impairment''. Diagnostische Wertigkeit verschiedener MR-Techniken

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, T.; Stieltjes, B.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung E010 Radiologie, Heidelberg (Germany); Thomann, P.A. [Zentrum fuer Psychosoziale Medizin, Universitaetsklinikum Heidelberg, AG Strukturelle Bildgebung, Klinik fuer Allgemeine Psychiatrie, Heidelberg (Germany)

    2011-04-15

    In view of an increasingly aging population the prevalence of dementia is also expected to increase rapidly. As well as clinical, neuropsychological and laboratory procedures magnetic resonance imaging (MRI) plays an important role in the early diagnosis of dementia which is important in the precursor stage of mild cognitive impairment (MCI). On the one hand this stage is associated with an increased risk of dementia and on the other hand an early treatment in this stage could attenuate development of the disease. In addition to morphological changes different functional MRI techniques can help in the early diagnosis of dementia and the precursor stages. Moreover, it is important to detect those MCI patients who are at particularly risk for developing dementia. In the differentiation of converters to non-converters initial studies suggest that particularly voxel-based morphometry, MR spectroscopy and diffusion tensor imaging can provide important additional information. (orig.) [German] Angesichts einer immer aelter werdenden Bevoelkerung sind wir mit dem Problem einer zunehmenden Zahl an Patienten mit Demenzerkrankungen konfrontiert. In der Fruehdiagnostik einer Demenz spielen neben klinischen, neuropsychologischen und laborchemischen Untersuchungen nichtinvasive Bildgebungsverfahren wie die MRT eine bedeutende Rolle. Wichtig ist dabei die Fruehdiagnostik einer Demenz bereits im Vorstadium der leichten kognitiven Beeintraechtigung (''mild cognitive impairment'', MCI), da dieses Krankheitsbild mit einem deutlich erhoehten Demenzrisiko einhergeht und durch eine fruehzeitige Therapie der Krankheitsverlauf abgemildert oder deutlich verzoegert werden kann. Neben morphologischen Veraenderungen helfen verschiedene funktionelle MR-Verfahren bei der Fruehdiagnostik einer Demenz. Darueber hinaus ist es von grosser Bedeutung, diejenigen MCI-Patienten zu detektieren, die in besonderem Masse von einer Demenz bedroht sind. Bei der Differenzierung von

  14. Typisierung von HLA-Klasse-II-Merkmalen mittels des TaqMan-Verfahrens

    OpenAIRE

    Tremmel, Matthias

    2001-01-01

    In Anlehnung an die konventionelle SSP-PCR-Methode wurde ein Low-Resolution-Panel mittels des TaqMan-Prinzips entwickelt und es wurde exemplarisch für DR4 und DR15/16 gezeigt, daß die auf dem 5 Nuklease-Assay beruhende Methode fähig ist, auch einzelne Punktmutationen voneinander zu unterscheiden. Das Grundprinzip dieser Methode basiert ähnlich dem der PCR-SSP auf dem Verfahren der PCR und auf dem Ausnutzen genetischer Unterschiede. So kommt es nur zu einer Amplifizierung wenn beide Primer spe...

  15. Modern cartilage imaging of the ankle

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph; Jungmann, Pia M.; Kuni, Benita

    2017-01-01

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  16. Indian, Japanese, And U.S. Responses To Chinese Submarine Modernization

    Science.gov (United States)

    2016-03-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited INDIAN, JAPANESE ...DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE INDIAN, JAPANESE , AND U.S. RESPONSES TO CHINESE SUBMARINE MODERNIZATION 5. FUNDING NUMBERS 6...is unlimited INDIAN, JAPANESE , AND U.S. RESPONSES TO CHINESE SUBMARINE MODERNIZATION David E. Kiser Lieutenant Commander, United States

  17. Optimization of MR fluid Yield stress using Taguchi Method and Response Surface Methodology Techniques

    Science.gov (United States)

    Mangal, S. K.; Sharma, Vivek

    2018-02-01

    Magneto rheological fluids belong to a class of smart materials whose rheological characteristics such as yield stress, viscosity etc. changes in the presence of applied magnetic field. In this paper, optimization of MR fluid constituents is obtained with on-state yield stress as response parameter. For this, 18 samples of MR fluids are prepared using L-18 Orthogonal Array. These samples are experimentally tested on a developed & fabricated electromagnet setup. It has been found that the yield stress of MR fluid mainly depends on the volume fraction of the iron particles and type of carrier fluid used in it. The optimal combination of the input parameters for the fluid are found to be as Mineral oil with a volume percentage of 67%, iron powder of 300 mesh size with a volume percentage of 32%, oleic acid with a volume percentage of 0.5% and tetra-methyl-ammonium-hydroxide with a volume percentage of 0.7%. This optimal combination of input parameters has given the on-state yield stress as 48.197 kPa numerically. An experimental confirmation test on the optimized MR fluid sample has been then carried out and the response parameter thus obtained has found matching quite well (less than 1% error) with the numerically obtained values.

  18. Percutaneous liver biopsy. Overview of different techniques; Perkutane Leberbiopsie. Uebersicht ueber verschiedene Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Kettenbach, J.; Blum, M.; El-RaBadi, K.; Langenberger, H.; Happel, B.; Berger, J.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Universitaet Wien (Austria)

    2005-01-01

    To classify a liver tumor, image-guided percutaneous biopsy of a liver lesion is indicated. Using ultrasound (US) to guide a biopsy needle into a liver lesion has been proven useful and safe. If a lesion cannot be seen on US or the access to a lesion has been complicated by its position, CT-guided biopsy can be performed. If a lesion cannot be delineated on US or CT, MR-guided biopsy is recommended. Using hepatospecific contrast agents, the time span to delineate tumor tissue can be prolonged. To differentiate diffuse liver disease, transvenous biopsy under fluoroscopic control can be performed if a percutaneous biopsy is contraindicated. In recent years fine-needle aspiration biopsy has been increasingly replaced by coaxial 14-20 G core biopsy, which is a safe and efficient technique to classify liver lesions and has a low complication rate. (orig.) [German] Zur definitiven Klaerung der Dignitaet und Tumorklasse einer Leberlaesion ist eine bildgesteuerte perkutane Biopsie indiziert. Unter Verwendung der Sonographie ist das Verfahren treffsicher und einfach. Die computertomographiegezielte Biopsie ist wegen der ueberlagerungsfreien, reproduzierbaren Darstellung von Leberherden und ihren Nachbarstrukturen in vielen Faellen besser geeignet. Fuer Laesionen, die sich weder mit Ultraschall noch mit CT biopsieren lassen, bietet sich die Magnetresonanztomographie an. Durch den Einsatz leberspezifischer Kontrastmittel kann das Zeitfenster zur Durchfuehrung einer Biopsie verlaengert werden. Zur Abklaerung diffuser Lebererkrankungen wird bei kontraindizierter perkutaner Biopsie eine transvenoese Leberbiopsie unter Durchleuchtung empfohlen. Die in den 1980er Jahren propagierte Feinnadelaspirationsbiopsie wurde zunehmend durch Stanzbiopsien (Durchmesser 14-20 gg) in koaxialer Technik ersetzt, da diese eine zuverlaessige artdiagnostische Klassifikation bei niedriger Komplikationsrate ermoeglichen. (orig.)

  19. Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus; Nichtinvasive Bestimmung des intrakraniellen Drucks. MR-basierte Untersuchung bei Kindern mit Hydrozephalus

    Energy Technology Data Exchange (ETDEWEB)

    Muehlmann, M.; Steffinger, D.; Ertl-Wagner, B.; Koerte, I.K. [Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Peraud, A. [Ludwig-Maximilians-Universitaet Muenchen, Abteilung fuer Neurochirurgie, Muenchen (Germany); Lehner, M. [Dr. von Haunersches Kinderspital, Ludwig-Maximilians-Universitaet Muenchen, Abteilung fuer Kinderchirurgie, Muenchen (Germany); Heinen, F.; Alperin, N. [University Miami, Department of Radiology, Miller School of Medicine, Miami (United States)

    2012-09-15

    -basierten Verfahrens (MR-ICP) bei Patienten mit Hydrozephalus vorgestellt. Der MR-ICP wird nichtinvasiv aus der intrakraniellen Volumenaenderung, die waehrend eines Herzzyklus entsteht, und dem kraniozervikalen Druckgradienten des Liquorflusses berechnet. Fuenfzehn Patienten mit Hydrozephalus, davon 6 (2,5-14,61 Jahre alt; Mittelwert 7,4 Jahre) mit Verdacht auf erhoehten ICP, und 9 ohne klinische Zeichen eines erhoehten ICP (2,1-15,9 Jahre alt; Mittelwert 9,8 Jahre) wurden an einem 3-T-MRT mittels Phasenkontrastangiographie untersucht. Der mediane MR-ICP der Patienten mit akuter Symptomatik lag bei 24,5 mmHg (25%-Perzentile 20,4 mmHg; 75%-Perzentile 44,5 mmHg). Der mediane MR-ICP der Patienten ohne akute Symptomatik war 9,8 mmHg (25%-Perzentile 8,6 mmHg; 75%-Perzentile 11,4 mmHg). Der Gruppenunterschied war signifikant (p <0,001; Mann-Whitney-U-Test). Der MR-ICP ist eine vielversprechende, nichtinvasive Methode zur Einschaetzung des ICP. Weitere Studien zur Evaluation der Anwendung bei verschiedenen klinischen Fragestellungen sind notwendig. (orig.)

  20. Ecological Modernization and Corporate Social Responsibility

    Directory of Open Access Journals (Sweden)

    Naira Tomiello

    2012-06-01

    Full Text Available This article discusses the role of social and environmental enterprises revealed in the concept of Corporate Social Responsibility (CSR and analyzed in the light of Ecological Modernization Theory (TME.The overall objective of this study is to understand CSR from the perspectiveof TME through more detailed research of a CSR program called  Clube dos Produtores [Producers Club].This program aims to influence the supply chain to adopt responsible and sustainable practices, and seeks to strengthen the small and medium producers through structured actions, such as training, qualification, and inspection, stimulating quality, innovation and productivity growth. It is conducted in parallel, in Portugal, by the Rede Sonae de Distribuição and, in Brazil, by Walmart Company. The data collection included both Countries. In Portugal, the Clube dos Produtores has emerged to combine the synergy between distribution and production and promote the development of domestic production. It takes the environment as the genesis for its creation, maintains a nationalist approach by encouraging the consumption of domestic products, and recognizes consumer pressure as the force for continuous innovation of products and services. In addition, it reconciles tradition and modernity through products supported by different generations. In Brazil, the Club is founded on the sustainability discourse; the customer awareness about environmental issues was not captured in the research; the producers innovations result from their own initiatives to participate in fairs or from direct contact with consumers; the dialogue between tradition and modernity occurs primarily through the entrepreneurial capacity of the producers and less direct intervention by Walmart.

  1. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  2. Neoadjuvant chemotherapy in breast cancer: prediction of pathologic response with PET/CT and dynamic contrast-enhanced MR imaging--prospective assessment.

    Science.gov (United States)

    Tateishi, Ukihide; Miyake, Mototaka; Nagaoka, Tomoaki; Terauchi, Takashi; Kubota, Kazunori; Kinoshita, Takayuki; Daisaki, Hiromitsu; Macapinlac, Homer A

    2012-04-01

    To clarify whether fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging performed after two cycles of neoadjuvant chemotherapy (NAC) can be used to predict pathologic response in breast cancer. Institutional human research committee approval and written informed consent were obtained. Accuracy after two cycles of NAC for predicting pathologic complete response (pCR) was examined in 142 women (mean age, 57 years: range, 43-72 years) with histologically proved breast cancer between December 2005 and February 2009. Quantitative PET/CT and DCE MR imaging were performed at baseline and after two cycles of NAC. Parameters of PET/CT and of blood flow and microvascular permeability at DCE MR were compared with pathologic response. Patients were also evaluated after NAC by using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 based on DCE MR measurements and European Organization for Research and Treatment of Cancer (EORTC) criteria and PET Response Criteria in Solid Tumors (PERCIST) 1.0 based on PET/CT measurements. Multiple logistic regression analyses were performed to examine continuous variables at PET/CT and DCE MR to predict pCR, and diagnostic accuracies were compared with the McNemar test. Significant decrease from baseline of all parameters at PET/CT and DCE MR was observed after NAC. Therapeutic response was obtained in 24 patients (17%) with pCR and 118 (83%) without pCR. Sensitivity, specificity, and accuracy to predict pCR were 45.5%, 85.5%, and 82.4%, respectively, with RECIST and 70.4%, 95.7%, and 90.8%, respectively, with EORTC and PERCIST. Multiple logistic regression revealed three significant independent predictors of pCR: percentage maximum standardized uptake value (%SUV(max)) (odds ratio [OR], 1.22; 95% confidence interval [CI]: 1.11, 1.34; P PET/CT is superior to DCE MR for the prediction of pCR (%SUV(max) [90.1%] vs %κ

  3. Characterization of a prototype MR-compatible Delta4 QA-system in a 1.5 tesla MR-linac

    NARCIS (Netherlands)

    de Vries, Wilfred J H; Seravalli, Enrica; Houweling, Anette; Woodings, Simon J; van Rooij, Rob; Wolthaus, Jochem W H; Lagendijk, JJW; Raaymakers, Bas W

    2018-01-01

    To perform patient plan-quality assurance (QA) on the newly installed MR-Linac (MRL) there was a need for having an MR-compatible QA-device. An MR compatible device (MR-Delta4) was developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response

  4. The Role of MR Enterography in Assessing Crohn’s Disease Activity and Treatment Response

    Directory of Open Access Journals (Sweden)

    Matthew P. Moy

    2016-01-01

    Full Text Available MR enterography (MRE has become the primary imaging modality in the assessment of Crohn’s disease (CD in both children and adults at many institutions in the United States and worldwide, primarily due to its noninvasiveness, superior soft tissue contrast, and lack of ionizing radiation. MRE technique includes distention of the small bowel with oral contrast media with the acquisition of T2-weighted, balanced steady-state free precession, and multiphase T1-weighted fat suppressed gadolinium contrast-enhanced sequences. With the introduction of molecule-targeted biologic agents into the clinical setting for CD and their potential to reverse the inflammatory process, MRE is increasingly utilized to evaluate disease activity and response to therapy as an imaging complement to clinical indices or optical endoscopy. New and emerging MRE techniques, such as diffusion-weighted imaging (DWI, magnetization transfer, ultrasmall superparamagnetic iron oxide- (USPIO- enhanced MRI, and PET-MR, offer the potential for an expanded role of MRI in detecting occult disease activity, evaluating early treatment response/resistance, and differentiating inflammatory from fibrotic strictures. Familiarity with MR enterography is essential for radiologists and gastroenterologists as the technique evolves and is further incorporated into the clinical management of CD.

  5. Mechanical/thermal dehydration - a new process for treatment of peat and coal; Mechanisch/Thermische Entwaesserung - ein neues Verfahren zur Veredelung von Torf und Kohlen

    Energy Technology Data Exchange (ETDEWEB)

    Bergins, C; Berger, S; Strauss, K [Dortmund Univ. (Germany); Elsen, R O [RWE Energie, Essen (Germany); Erken, M [Rheinbraun AG, Koeln (Germany); Bielfeldt, F B [Dieffenbacher, Eppingen (Germany)

    1998-09-01

    In order to keep German brown coal competitive, new technologies for enhanced efficiency of power generation from brown coal were developed in the past few years. At a water content of 50-60 percent by weight, much energy is lost for evaporation. Reduction of the water content will incur a 5 percent effiency enhancement. A new process was developed at Dortmund university, i.e. mechanical/thermal dehydration in which the water contained in brown coal is removed by heat and mechanical pressure. The process is described, and its applicability for other moist fuels, e.g. peat or waste from the paper and wood processing industry ist discussed. (orig./SR) [Deutsch] Damit Braunkohle in Deutschland als heimischer und subventionsfreier Energietraeger diesen Stellenwert behaupten und in Zukunft weiter ausbauen kann, wurde in den letzten Jahren verstaerkt die Entwicklung neuer Technologien zur Effizienzsteigerung der Braunkohleverstromung vorangetrieben. Bei der Verbrennung von Braunkohlen mit Wassergehalten von 50-60 Gew.-% ist in herkoemmlichen Kraftwerken ein erheblicher Teil des Energieinhaltes zur Verdampfung des Wassers mit Hilfe von heissen Rauchgasen in sogenannten Mahltrockungsanlagen erforderlich. Durch eine energetisch guenstige Reduzierung des Wassergehaltes vor der Verbrennung sind hier Wirkungsgradsteigerungen um bis zu 5 Prozentpunkte moeglich. Ein neues, fuer diese Aufgabenstellung einsetzbares Verfahren ist das am Lehrstuhl Energieprozesstechnik und Stroemungsmechanik der Universitaet Dortmund entwickelte Mechanisch/Thermische Entwaesserungsverfahren (MTE-Verfahren). Durch die kombinierte Anwendung von Waerme und mechanischem Druck laesst sich das in der Kohle enthaltene Wasser in fluessiger Form entfernen. Neben der Darstellung des MTE-Verfahrens am Beispiel von Braunkohle soll im folgenden auch auf die Moeglichkeiten der Anwendung des Verfahrens fuer andere feuchte Brennstoffe wie Torf und Abfaelle aus der Papier- und Holzverarbeitung eingegangen werden

  6. Gasification of residual waste by the PreCon {sup trademark} process on the basis of high-temperature Winkler gasification (HTW); Vergasung von Restmuell nach dem PreCon {sup trademark} -Verfahren auf Basis der Hochtemperatur-Winkler Vergasung (HTW)

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J; Luetge, C; Deutsch, M [Krupp Uhde GmbH, Dortmund (Germany); Wischnewski, R; Mittelstaedt, A [Rheinbraun AG, Koeln (Germany)

    1998-09-01

    The HTW process is an established technology. Experiments in the laboratory and in a demonstration plant resulted in a valid design basis for the PreCon {sup trademark} process. The economic efficiency and competitive strength of the process is outlined. (orig./SR) [Deutsch] Das HTW-Verfahren praesentiert sich als eine bewaehrte, grosstechnisch erprobte Technologie fuer eine geaenderte Applikation. Die Umsetzung der in den Versuchen im Technikum und an der Demonstrationsanlage gewonnenen positiven Ergebnisse fuehrt zu einer abgesicherten Auslegungsgrundlage fuer das PreCon {sup trademark} -Verfahren. Die Wirtschaftlichkeit und Wettbewerbsfaehigkeit des Verfahrens laesst sich schon heute darstellen. (orig./SR)

  7. Methodological principles for optimising functional MRI experiments; Methodische Grundlagen der Optimierung funktioneller MR-Experimente

    Energy Technology Data Exchange (ETDEWEB)

    Wuestenberg, T. [Georg-August-Universitaet Goettingen, Abteilung fuer Medizinische Psychologie (Germany); Georg-August-Universitaet, Abteilung fuer Medizinische Psychologie, Goettingen (Germany); Giesel, F.L. [Deutsches Kebsforschungszentrum (DKFZ) Heidelberg, Abteilung fuer Radiologische Diagnostik (Germany); Strasburger, H. [Georg-August-Universitaet Goettingen, Abteilung fuer Medizinische Psychologie (Germany)

    2005-02-01

    Functional magnetic resonance imaging (fMRI) is one of the most common methods for localising neuronal activity in the brain. Even though the sensitivity of fMRI is comparatively low, the optimisation of certain experimental parameters allows obtaining reliable results. In this article, approaches for optimising the experimental design, imaging parameters and analytic strategies will be discussed. Clinical neuroscientists and interested physicians will receive practical rules of thumb for improving the efficiency of brain imaging experiments. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) des Zentralnervensystems ist eine der meistgenutzten Methoden zur Lokalisierung neuronaler Aktivitaet im Gehirn. Obwohl die Sensitivitaet der fMRT vergleichsweise gering ist, kann durch die Auswahl geeigneter experimenteller Parameter die Empfindlichkeit dieses bildgebenden Verfahrens gesteigert und die Reliabilitaet der Ergebnisse gewaehrleistet werden. In diesem Artikel werden deshalb Ansaetze fuer die Optimierung des Paradigmendesigns, der MR-Bildgebung und der Datenauswertung diskutiert. Klinischen Forschern und interessierten Aerzten sollen dadurch Richtgroessen fuer die Durchfuehrung effektiver fMRT-Experimente vermittelt werden. (orig.)

  8. Survey of damage to 602 MR scanners after the Great East Japan Earthquake

    International Nuclear Information System (INIS)

    Nakai, Toshiharu; Yamaguchi-Sekino, Sachiko; Tsuchihashi, Toshio

    2013-01-01

    An earthquake of 9.0 magnitude, the largest in modern Japanese history, struck east Japan on March 11, 2011. We investigated hazards and observations related to magnetic resonance (MR) scanners in this earthquake to evaluate potential risks and consider further prevention or minimization of damage from and injury of patients in such large earthquakes. The investigation team funded by MHLW sent questionnaires to the 984 facilities with installed MR scanners in the 7 prefectures of east Japan (Iwate, Miyagi, Fukushima, Ibaraki, Chiba, Tokyo, Saitama) and collected 458 responses (46.6%) with information on 602 MR scanners (144 units≤0.5 tesla; 31 one-T units; 371 1.5-T units; and 56 units≥3 T). Significant differences in damage were observed between seismic scale 5 and 6 (χ 2 test, P<0.001 for all items of damage checked). The frequencies of typical damage were displacement of magnets (12.4%), failure of the chiller or air conditioning (9.6%), rapid decrease in liquid helium (8.4%), damage to magnet enclosure and its equipment (7.6%), damage to shielding of the MR scanner room (6.1%), damage to the quench duct (4.5%), breakage of devices anchoring system cabinets (4.4%), damage to the magnet base (3.9%), and flying of metal components (1.5%). Twelve facilities reported flooding by the subsequent tsunami, and quench was confirmed in 19 facilities. No fire damage was reported. It was confirmed that no one was severely injured in MR scanners, and base isolation of the building was very useful in completely preventing damage even at seismic scale 7. In the future, training for evacuation and establishment of a standard protocol for emergency shutdown of MR scanners, onsite checking by MR operators, and emergency power plant equipment to maintain chiller for MR scanners will further ensure MR safety in an earthquake. (author)

  9. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin; Hollingsworth, Alan B.; Qian, Wei

    2015-01-01

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy

  10. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin, E-mail: Bin.Zheng-1@ou.edu [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Hollingsworth, Alan B. [Mercy Women’s Center, Mercy Health Center, Oklahoma City, Oklahoma 73120 (United States); Qian, Wei [Department of Electrical and Computer Engineering, University of Texas, El Paso, Texas 79968 (United States)

    2015-11-15

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

  11. An algorithm for calculating unsteady flow with free surface; Ein Verfahren zur Berechnung instationaerer Stroemungen mit freier Oberflaeche

    Energy Technology Data Exchange (ETDEWEB)

    Janetzky, B.

    2001-07-01

    A numerical model for the transient, free surface flow is implemented in a Finite-Element program for the unsteady calculation of incompressible flow with free surface. The program is used to calculate the flow in different components of a hydraulic turbine, the Pelton turbine. The movement of the fluid with free surface is described mathematically by introducing a partial differential equation for the volume fraction. This equation is simply a transport equation for f, i.e. the volume fraction is advected with the flow in time. The equations is solved numerically. (orig.) [German] Es wird ein Verfahren zur Modellierung von veraenderlichen, freien Oberflaechen vorgestellt und in einem Finite-Elemente-Programm zur numerischen Berechnung von instationaeren, inkompressiblen Stroemungen implementiert. Die veraenderliche, freie Oberflaeche wird mit einem Volume-Of-Fluid Ansatz erfasst. Zur Approximierung der freien Oberflaeche werden stueckweise konstante oder gestufte Verlaeufe im Element angesetzt. Es werden die Eigenschaften des Verfahrens an ausgewaehlten Beispielen mit freier Oberflaeche untersucht. Das erweiterte Programm wird auf instationaere Stroemungen mit freier Oberflaeche in einer hydraulischen Maschine, der Peltonturbine, angewandt. (orig.)

  12. Pre-operative radiotherapy in soft tissue tumors: Assessment of response by static post-contrast MR imaging compared to histopathology

    International Nuclear Information System (INIS)

    Einarsdottir, H.; Wejde, J.; Bauer, H.C.F.

    2000-01-01

    To evaluate if static post-contrast MR imaging was adequate to assess tumor viability after pre-operative radiotherapy in soft tissue sarcoma. Post-contrast MR imaging of 36 soft tissue sarcomas performed 0 - 54 days (median 13 days) after pre-operative radiotherapy, were retrospectively reviewed and compared to post-operative histopathology reports. The contrast enhancement of the tumor was visually graded as minor, moderate or extensive. From the post-operative histopathology reports, three types of tumor response to radiotherapy were defined: Poor, intermediate or good. The size of the tumors before and after radiation was compared. Even if most viable tumors enhanced more than non-viable tumors, there was major overlapping and significant contrast enhancement could be seen in tumors where histopathological examination revealed no viable tumor tissue. Based on histopathology, there were 12 good responders; 8 of these showed minor, 3 moderate and 1 extensive contrast enhancement on MR imaging. Sixteen tumors had an intermediate response; 3 showed minor, 8 moderate and 5 extensive enhancement. Eight tumors had poor response; none showed minor enhancement, 3 moderate and 5 extensive enhancement. Both increase and Decrease in tumor size was seen in lesions with a good therapy response. Static post-contrast MR imaging cannot reliably assess tumor viability after pre-operative radiotherapy in soft tissue sarcoma. In tumors with no viable tumor tissue, moderate and extensive contrast enhancement can be seen

  13. Investigations on pretreatment of waste prior to fermentation by percolation using the ISKA {sup registered} process; Untersuchungen zur Vorbehandlung von Abfaellen vor der Vergaerung mittels Perkolation nach dem ISKA {sup registered} -Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Santen, H. [Technische Univ. Braunschweig (Germany). FG Abfallwirtschaft; Fricke, K. [Technische Univ. Braunschweig (Germany). Lehrstuhl Abfallwirtschaft; Engelhard, T.; Widmer, C. [ISKA GmbH, Ettlingen (Germany)

    2004-07-01

    Waste treatment prior to fermentation is a key aspect in achieving economic efficiency. One process is presented here in particular: percolation, in which waste is hydrolyzed aerobically, treated mechanically, and washed out with the aid of process water. The process involves a percolation stage followed by a fermentation stage. The process water burdened with organic matter is passed into a fermentation reactor in which the organic components are reacted anaerobically into biogas and bacterial mass, and the process water is recirculated into the percolation reactor. (orig.) [German] Vergaerungstechnologien zaehlen zu den etablierten Verfahren zur Gewinnung regenerativer Energien aus Biomasse. Fuer die Energieeffizienz dieser Verfahren sind die Leistung der Vergaerungsstufe, die Hoehe der Verfuegbarkeit der anaerob abzubauenden organischen Substanzen und der spezifische Energiebedarf des Behandlungsverfahrens massgeblich. Eine Schluesselstellung fuer die Optimierung beider Faktoren nimmt die Abfallaufbereitung vor der Vergaerung ein. Eine Technoloie zur Aufbereitung vor der Vergaerung basiert auf dem Verfahren der Perkolation, in der der Abfall aerob hydrolysiert,mechanisch aufgeschlossen und durch Zugabe von Prozesswasser ausgewaschen wird. Das Verfahren besteht aus einer Aufbereitung - der Perkolation - sowie einer nachgeschalteten Vergaerung. Das mit vergaerbarer Organik beladene Prozesswasser wird einem Vergaerungsreaktor zugefuehrt, in dem die organischen Komponenten anaerob zu Biogas und Bakterienmasse umgesetzt werden. Das aufbereitete Prozesswasser wird anschliessend wieder dem Perkolationsreaktor zugefuehrt. (orig.)

  14. Mr imaging and mr spectroscopy of brain metastases by mr perfusion

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Lichy, M.P.; Thilmann, C.; Guenther, M.; Bachert, P.; Delorme, S.; Schad, L.R.; Debus, J.; Schlemmer, H.P.; Maudsley, A.A.

    2003-01-01

    In follow-up examinations of irradiated brain metastases conventional contrast-enhanced morphological MR imaging is often unable to distinguish between transient radiation effects, radionecrosis, and tumor recurrence. To evaluate changes of relative cerebral blood flow (rCBF) in irradiated brain metastases arterial spin-labeling techniques (ASL) were applied and compared to the outcome of 1 H MR spectroscopy and spectroscopic imaging ( 1 H MRS, SI). Patients and methods In 2 patients follow-up examinations of irradiated brain metastases were performed on a 1.5-T tomograph (average single dose: 20 Gy/80% isodose). Relative CBF values of gray matter (GM), white matter (WM), and metastases (Met) were measured by means of the ASL techniques ITS-FAIR and Q2TIPS. 1 H MRS was performed with PRESS 1500/135. In both patients with initially hyperperfused metastases (Met/GM >1) the reduction of rCBF after stereotactic radiosurgery indicated response to treatment - even if the contrast-enhancing region increased - while increasing rCBF values indicated tumor progression. The findings were confirmed by 1 H MRS, SI and subsequent follow-up. The ASL techniques ITS-FAIR and Q2TIPS are able to monitor changes of rCBF in irradiated brain metastases. The two cases imply a possible role for ASL-MR perfusion imaging and 1 H MR spectroscopy in differentiating radiation effects from tumor progression. (orig.) [de

  15. Prediction of Early Response to Chemotherapy in Lung Cancer by Using Diffusion-Weighted MR Imaging

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2014-01-01

    Full Text Available Purpose. To determine whether change of apparent diffusion coefficient (ADC value could predict early response to chemotherapy in lung cancer. Materials and Methods. Twenty-five patients with advanced non-small cell lung cancer underwent chest MR imaging including DWI before and at the end of the first cycle of chemotherapy. The tumor’s mean ADC value and diameters on MR images were calculated and compared. The grouping reference was based on serial CT scans according to Response Evaluation Criteria in Solid Tumors. Logistic regression was applied to assess treatment response prediction ability of ADC value and diameters. Results. The change of ADC value in partial response group was higher than that in stable disease group (P=0.004. ROC curve showed that ADC value could predict treatment response with 100% sensitivity, 64.71% specificity, 57.14% positive predictive value, 100% negative predictive value, and 82.7% accuracy. The area under the curve for combination of ADC value and longest diameter change was higher than any parameter alone (P≤0.01. Conclusions. The change of ADC value may be a sensitive indicator to predict early response to chemotherapy in lung cancer. Prediction ability could be improved by combining the change of ADC value and longest diameter.

  16. Computer-aided global breast MR image feature analysis for prediction of tumor response to chemotherapy: performance assessment

    Science.gov (United States)

    Aghaei, Faranak; Tan, Maxine; Hollingsworth, Alan B.; Zheng, Bin; Cheng, Samuel

    2016-03-01

    Dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI) has been used increasingly in breast cancer diagnosis and assessment of cancer treatment efficacy. In this study, we applied a computer-aided detection (CAD) scheme to automatically segment breast regions depicting on MR images and used the kinetic image features computed from the global breast MR images acquired before neoadjuvant chemotherapy to build a new quantitative model to predict response of the breast cancer patients to the chemotherapy. To assess performance and robustness of this new prediction model, an image dataset involving breast MR images acquired from 151 cancer patients before undergoing neoadjuvant chemotherapy was retrospectively assembled and used. Among them, 63 patients had "complete response" (CR) to chemotherapy in which the enhanced contrast levels inside the tumor volume (pre-treatment) was reduced to the level as the normal enhanced background parenchymal tissues (post-treatment), while 88 patients had "partially response" (PR) in which the high contrast enhancement remain in the tumor regions after treatment. We performed the studies to analyze the correlation among the 22 global kinetic image features and then select a set of 4 optimal features. Applying an artificial neural network trained with the fusion of these 4 kinetic image features, the prediction model yielded an area under ROC curve (AUC) of 0.83+/-0.04. This study demonstrated that by avoiding tumor segmentation, which is often difficult and unreliable, fusion of kinetic image features computed from global breast MR images without tumor segmentation can also generate a useful clinical marker in predicting efficacy of chemotherapy.

  17. Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac

    Science.gov (United States)

    de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-01-01

    To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (tesla magnetic field of the Elekta MR-linac

  18. Diagnostic imaging in psychiatry; Bildgebende Verfahren in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Stoppe, G.; Hentschel, F.; Munz, D.L. (eds.)

    2000-07-01

    The textbook presents an exhaustive survey of diagnostic imaging methods available for clinical evaluation of the entire range of significant psychiatric symptoms via imaging of the anatomy and functions of the brain. The chapters discuss: The methods and their efficient use for given diagnostic objectives, image analysis, description and interpretation of findings with respect to the clinical symptoms. Morphology and functional correlation of findings. The book is intended to help psychiatrists and neurologists as well as doctors in the radiology and nuclear medicine departments. (orig./CB) [German] Die Entwicklung der modernen Bildgebung ermoeglicht faszinierende Einblicke in Anatomie und Funktionen des Gehirns und ihre Veraenderungen bei psychiatrischen Erkrankungen. Die Methodik der Untersuchungsverfahren und die Befunde bei allen wichtigen psychiatrischen Krankheitsbildern sind in diesem Buch systematisch und umfassend beschrieben: - gezielter und effizienter Einsatz der Verfahren, - Bildanalyse und Befundbeschreibung, - Bewertung der Befunde und Beziehung zum klinischen Bild, - morphologische und funktionelle Korrelate der Befunde. Psychiater und Neurologen werden ebenso angesprochen wie Radiologen und Nuklearmediziner. (orig.)

  19. MR urography: examination techniques and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Adam, G.B.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2001-03-01

    Modern MR urography is performed on the basis of two different imaging strategies, which can be used complementarily to cover almost all aspects in the diagnosis of upper urinary tract diseases. The first technique utilizes unenhanced, heavily T2-weighted pulse sequences to obtain static-fluid images of the urinary tract. T2-weighted MR urograms have proved to be excellent in the visualization of the markedly dilated urinary tract, even if the renal excretory function is quiescent. Static-fluid MR urography is less suitable for imaging of disorders that occur in the nondilated collecting system. The second MR urography technique is analogous to the methodology of conventional intravenous pyelography and is, therefore, designated as excretory MR urography. For this purpose, a non-nephrotoxic gadolinium chelate is intravenously administered and after its renal excretion, the gadolinium-enhanced urine is visualized using fast T1-weighted gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of the contrast material inside the entire urinary tract and, secondly, to avoid high endoluminal gadolinium concentrations, which cause signal loss of the urine due to T2{sup *} effects. Gadolinium excretory MR urography allows to obtain high-quality images of both nondilated and obstructed urinary tracts in patients with normal or moderately impaired renal function. This article reviews the principles of T2- and T1-weighted MR urography in detail and informs how to use these techniques safely in potential clinical applications such as chronic urolithiasis, intrinsic and extrinsic tumor diseases, and congenital anomalies. Magnetic resonance urography performed in combination with standard MR imaging offers a potential to reduce the need for invasive retrograde pyelography. Although the economic aspect is still problematic, it is obvious that MR urography will continue to increase its role in

  20. Physiological and technical limitations of functional magnetic resonance imaging (fMRI) - consequences for clinical use; Physiologische und technische Grenzen der funktionellen Magnetresonanztomographie und die damit verbundenen Konsequenzen fuer die klinische Anwendung

    Energy Technology Data Exchange (ETDEWEB)

    Wuestenberg, T. [Neurologische Klinik der Charite, Humboldt-Universitaet Berlin (Germany); Neurologische Klinik der Charite, Humboldt-Universitaet Berlin, Schumannstrasse 20/21, 10117, Berlin (Germany); Jordan, K. [Institut fuer Psychologie II, Otto-von-Guericke-Universitaet Magdeburg (Germany); Giesel, F.L. [Abteilung fuer onkologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum Heidelberg (Germany); Villringer, A. [Neurologische Klinik der Charite, Humboldt-Universitaet Berlin (Germany)

    2003-07-01

    Functional magnetic resonance imaging (fMRI) is the most common noninvasive technique in functional neuroanatomy. The capabilities and limitations of the method will be discussed based on a short review of the current knowledge about the neurovascular relationship. The focus of this article is on current methodical and technical problems regarding fMRI-based detection and localization of neuronal activity. Main error sources and their influence on the reliability and validity of fMRI-methods are presented. Appropriate solution strategies will be proposed and evaluated. Finally, the clinical relevance of MR-based diagnostic methods are discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) ist eines der wichtigsten Verfahren der funktionellen Neuroanatomie. Aufbauend auf einer kurzen Darstellung des aktuellen Wissensstands bzgl. des Zusammenhangs zwischen lokaler neuronaler Aktivitaet und haemodynamischer Reaktion werden ausgewaehlte Moeglichkeiten und Grenzen des Verfahrens fuer die klinische Anwendung diskutiert. Der Schwerpunkt liegt dabei auf der Darstellung der derzeitigen methodischen und technischen Einschraenkungen hinsichtlich einer fMRT-basierten Detektion und Lokalisierung neuronaler Aktivitaet. Es werden die Hauptfehlerquellen und ihre Auswirkungen auf die Reliabilitaet und Validitaet des Verfahrens erlaeutert und aktuelle Loesungsansaetze diskutiert. Abschliessend erfolgt eine Bewertung der aktuellen klinischen Relevanz funktioneller MR-Diagnosemethoden. (orig.)

  1. MR imaging of metabolic white matter diseases: Therapeutic response

    International Nuclear Information System (INIS)

    Gebarski, S.S.; Allen, R.

    1987-01-01

    In metabolic diseases affecting the brain, MR imaging abnormalities include white-matter signal aberrations suggesting myelination delay, dysmyelination and demyelination, pathologic iron storage, and finally, loss of substance usually in a nonspecific pattern. The authors suggest that MR imaging may have therapeutic implications: (1) classic galactosemia - white-matter signal aberration became normal after dietary therapy; (2) phenylketonuria - age- and sex-matched treated and nontreated adolescents showed marked differences in brain volume, with the treated patient's volume nearly normal; (3) maple syrup urine disease - gross white-matter signal aberration became nearly normal after dietary therapy; and (4) hyperglycinemia - relentless progression of white-matter signal aberration and loss of brain substance despite therapy. These data suggest that brain MR imaging may provide a therapeutic index in certain metabolic diseases

  2. Non-destructive testing of concrete structures with the impact-echo method; Zerstoerungsfreie Pruefung von Betonbauteilen mit dem Impact-Echo-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Algernon, Daniel; Feistkorn, Sascha; Scherrer, Michael [SVTI Schweizerischer Verein fuer technische Inspektionen, Wallisellen (Switzerland). Nuklearinspektorat

    2016-05-01

    The impact-echo method is based on the use of elastic waves. It was developed in the 1980 for the testing of concrete structures and is currently widespread. Main application areas are the component and coating thickness measurement and detection of delaminations, voids and other defects. Specifically, the method is also used to check the injection faults of clamping channels. Another application is the determination of mechanical material parameters such as the modulus of elasticity. Since the original development of the method has undergone several enhancements. The conversion of a single-point measurement method towards a area component testing, the use by the optimized measurement data acquisition and evaluation enlarged and delivered an important prerequisite for increasing the efficiency. The use of air-coupled sensors not only increases the measurement speed but also provides advantages in rough component surfaces. The imaging analysis in conjunction with signal processing algorithms simplifies the interpretation and allows statistical evaluation. [German] Das Impact-Echo-Verfahren beruht auf der Nutzung elastischer Wellen. Es wurde in den 1980er Jahren fuer die Pruefung von Stahlbetonbauteilen entwickelt und ist derzeit weit verbreitet. Haupteinsatzgebiete sind die Bauteil- und Schichtdickenmessung sowie die Detektion von Delaminationen, Hohl- und anderen Fehlstellen. Insbesondere wird das Verfahren auch zur Pruefung des Verpresszustandes von Spannkanaelen herangezogen. Eine weitere Anwendung ist die Bestimmung mechanischer Materialparameter wie dem Elastizitaetsmodul. Seit der urspruenglichen Entwicklung hat das Verfahren verschiedene Weiterentwicklungen erfahren. Die Ueberfuehrung von einem Einzelpunktmessverfahren hin zu einer flaechigen Bauteilpruefung hat die Einsatzmoeglichkeiten durch die optimierte Messdatenaufnahme und -auswertung vergroessert und eine wichtige Voraussetzung zur Erhoehung der Leistungsfaehigkeit geliefert. Der Einsatz

  3. CT and MR urography

    International Nuclear Information System (INIS)

    Hadjidekov, G.

    2012-01-01

    Full text: Learning objectives:1) To describe the techniques of CT Urography and of MR urography; 2) To illustrate the benefit of the methods in clinical practice; 3)To present typical cases from the daily practice CT has become the mainstay of uroradiology in adults. CT urography is an excellent technique for the evaluation of urinary tract calculi, trauma, infections, complicated cysts, renal masses, having high sensitivity and specificity for both conditions facilitated by the possibilities for multiplanar imaging of the urinary system. It resembles excretory urography and consists of unenhanced, nephrographic, and pyelographic phases and can be used even as routine investigation. MR urography is a new, modern modality for evaluation of various urological abnormalities providing both morphological and functional information by means of different sequences with or without injection of gadolinium. The method is clinically useful in the evaluation of the collecting system, various variants and congenital abnormalities of the kidney, different cases of obstruction of the excretory system, tumors and inflammatory processes, hematuria. Compared to CT urography, MR urography is particularly beneficial in pediatric group or pregnant patients. It can also be performed in patients with renal insufficiency, iodine allergy and other cases of contraindications to the use of ionizing radiation. CT and MR urography are promising diagnostic methods of the wide spectrum of pathological conditions affecting the urinary tract. They are highly informative and overcome a lot of limitations of the other imaging modalities with the potential to become leading modalities to diagnose kidney diseases and other urogenital disorders.

  4. OCR-D - Koordinierte Förderinitiative zur Weiterentwicklung von OCR-Verfahren

    Directory of Open Access Journals (Sweden)

    Elisa Herrmann

    2017-12-01

    Full Text Available Das Projekt OCR-D hat zum Ziel, das Verfahren der automatischen Texterkennung historischer Texte weiterzuentwickeln. Nach einer primären Phase der Bedarfsanalyse folgt 2018 die Modulprojektphase. Der vorliegende Artikel beschreibt in Kürze das in der ersten Projektphase erarbeitete Funktionsmodell von OCR-D und geht auf die Herausforderungen der einzelnen Prozessschritte ein. Für diese sollen die Modulprojekte zukünftig Lösungen erarbeiten. The OCR-D Project aims to refine the process of automatic text recognition especially for historical texts. After an initial analysis of the requirements in the first phase of the project, the second project phase – the module project phase – will start in 2018. The article describes the function model of OCR-D and addresses the challenges which have to be met at different process steps. These are supposed to be solved in the module projects

  5. Überblick zu Additive-Manufacturing-Verfahren im Industrie-Einsatz: Vortrag gehalten auf dem 1. VDI-Strategiekongress "Additive Manufacturing" 2017, Technologien - Globale Produktionsverbünde 4.0 - neue Geschäftsmodelle, 21. - 22. März 2017, Stuttgart

    OpenAIRE

    Müller, Bernhard

    2017-01-01

    Die additive Fertigung von Komponenten ermöglicht vollkommen neue Wege in der Entwicklung und Fertigung innovativer Bauteile und Produkte. Das Spektrum am Markt verfügbarer sowie neu an den Markt gelangender additiver Fertigungsverfahren ist weit und unübersichtlich. Einige wenige Verfahren haben bereits heute einen Status erreicht, der serienhafte industrielle Applikation möglich macht. Dazu gehört zum Beispiel das pulverbett- und laserbasierte Verfahren Laser-Strahlschmelzen zur additiven H...

  6. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  7. Entwicklung und Anwendung bildgebender Verfahren für die Messung der elektrischen Feldstärke mit Hilfe der Lochbrennspektroskopie

    OpenAIRE

    Balzer, Herbert

    2002-01-01

    In der Arbeit wird ein neues bildgebendes Verfahren zur optischen Sensorik der elektrischen Feldstärke vorgestellt, das auf der laserspektroskopischen Methode des stabilen spektralen Lochbrennens beruht. Hierbei erfolgt die Bestimmung der Feldstärkeverteilung durch Messung der E-Feldinduzierten Änderung der Absorption im Zentrum eines stabilen spektralen Loches, das mit einem schmalbandigen Laser in das Absorptionsspektrum einer Sensorschicht, bestehend aus dem Polymer Polyvinylbutyral dotier...

  8. REVIEW Interpretation and value of MR CSF flow studies for ...

    African Journals Online (AJOL)

    children should be able to request this procedure from any MR imaging department, and should ... on all modern 1.5T scanners equipped with standard software and phase contrast magnetic resonance (PCMR) capabilities and analysis packages. .... Follow-up imaging demonstrates change in CSF flow to a unidirectional.

  9. LOCUS MR: Localization of unaffected spins in MR tomography and MR spectroscopy

    International Nuclear Information System (INIS)

    Matthael, D.; Haase, A.

    1986-01-01

    Different pulse sequences have been proposed for localized in vivo MR spectroscopy. For localized MR tomography and MR spectroscopy, a method is proposed, dubbed LOCUS (LOCalization of Unaffected Spins) MR. The method uses the initial saturation of regions surrounding the region of interest (ROI) in the presence of gradients. This is followed by a conventional MR study of the unaffected ROI. In animals, human extremities, and phantoms, proton MR studies demonstrated that the method provides an optimal signal-to-noise ratio, an easily variable ROI, and ROI shim. The method can be combined with two- and three-dimensional imaging, and it allows localized measurement of MR parameters. The multinuclear capability is discussed

  10. Redox-responsive manganese dioxide nanoparticles for enhanced MR imaging and radiotherapy of lung cancer

    Science.gov (United States)

    Cho, Mi Hyeon; Choi, Eun-Seok; Kim, Sehee; Goh, Sung-Ho; Choi, Yongdoo

    2017-12-01

    In this study, we synthesized manganese dioxide nanoparticles (MnO2 NPs) stabilized with biocompatible polymers (polyvinylpyrrolidone and polyacrylic acid) and analyzed their effect on non-small cell lung cancer (NSCLC) cells with or without gefitinib resistance in vitro. MnO2 NPs showed glutathione (GSH)-responsive dissolution and subsequent enhancement in magnetic resonance (MR) imaging. Of note, treatment with MnO2 NPs induced significant cytotoxic effects on NSCLC cells, and additional dose-dependent therapeutic effects were obtained upon X-ray irradiation. Normal cells treated with MnO2 NPs were viable at the tested concentrations. In addition, increased therapeutic efficacy could be achieved when the cells were treated with MnO2 NPs in hypoxic conditions. Therefore, we conclude that the use of MnO2 NPs in MR imaging and combination radiotherapy may be an efficient strategy for the imaging and therapy of NSCLC.

  11. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  12. Interventional diagnostic breast procedures; Diagnostische Mammainterventionen

    Energy Technology Data Exchange (ETDEWEB)

    Bick, U. [Inst. fuer Radiologie, Universitaetsklinikum Charite, Berlin (Germany); Dept. of Radiology, The Univ. of Chicago (United States); Diekmann, S.; Diekmann, F. [Inst. fuer Radiologie, Universitaetsklinikum Charite, Berlin (Germany)

    2001-09-01

    The comprehensive survey describes in great detail the indications, performance, and advantages and drawbacks of the various biopsy and localization techniques available today for interventional diagnostic evaluation of lesions of the breast. (orig./CB) [German] Die Feinnadelaspirationszytologie ist einfach und rasch durchfuehrbar, ist jedoch insbesondere in der Hand von unerfahrenen Untersuchern mit einer relativ hohen Rate von nicht auswertbaren und falsch-negativen Befunden verbunden. Das Verfahren wird am haeufigsten bei soliden oder zystischen Herdbefunden eingesetzt, die palpabel oder sonographisch nachweisbar sind. Bei inadaequatem Zellmaterial muss eine erneute Biopsie, ggf. mit einem anderen Verfahren, erfolgen. Die Nadelstanzbiopsie ist heutzutage das Verfahren der Wahl bei mammographisch oder sonographisch sichtbaren soliden Herdbefunden. Das Verfahren ist einfach und kostenguenstig durchfuehrbar und weist bei soliden Herdbefunden eine extrem hohe Sensitivitaet und Spezifitaet auf. Bei Mikroverkalkungen sollten immer ausreichend viele Stanzen (5 und mehr) entnommen werden. Bei Stanzbiopsien besteht grundsaetzlich die Gefahr einer Unterschaetzung des histologischen Befundes (ADH statt DCIS, in situ statt invasiv). Bei Diagnose ADH in der Stanzbiopsie sollte eine Exzision des Befundes erfolgen. Die vakuumassistierte Stanzbiopsie ist besonders beeignet zur Biopsie von unklaren Mikroverkalkungen, da durch die groessere entnommene Gewebemenge eine hoehere Spezifitaet und Sensitivitaet erreicht werden kann. Fuer MR-gesteuerte Biopsien hat dieses Verfahren den Vorteil, dass die Nadel nur einmal platziert werden muss. Die stereotaktische Exzisionsbiopsie ist ein relativ teures und invasives Verfahren, das insbesondere zur diagnostischen Abklaerung von unklaren Mikroverkalkungen eingesetzt wird. Hierbei steht das Verfahren in direkter Konkurrenz zur vakuumassistierten Stanzbiopsie. Inwieweit es fuer die stereotaktische Exzisionsbiopsie wirklich ein

  13. Processes, spheres of use and importance of sewage sludge disintegration; Verfahren, Einsatzgebiete und Bedeutung der Klaerschlammdesintegration

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, J. [Technische Univ. Braunschweig (Germany). Inst. fuer Siedlungswasserwirtschaft; Technische Univ. Braunschweig (Germany). Inst. fuer Mechanische Verfahrenstechnik

    1999-07-01

    The paper gives an overview of results attained by means of mechanical sludge disintegration methods and compares them with thermal and ozone treatment. The objective is to describe in scientific as well as application-oriented terms the opportunities held and limits to this process step of sludge treatment. (orig.) [German] Im Rahmen des Beitrags wird eine Uebersicht ueber die mit mechanischen Verfahren der Schlammdesintegration erreichten Ergebnisse und ein Vergleich mit der Waerme- und der Ozonbehandlung gegeben. Ziel des Beitrages ist es, die Moeglichkeiten und Grenzen dieses Prozessschrittes der Schlammbehandlung aus wissenschaftlicher wie aus anwendungsorientierter Sicht darzustellen. (orig.)

  14. ETVS - a process for decentral processing of liquid, pasty and solid organic residues into electrical energy and ash, optionally with hydrosoft high-pressure dewatering, fluidized-bed drying, fluidized-bed gasification and heat-and-power cogeneration using product gas; ETVS - Ein Verfahren zur dezentralen Verwertung von fluessigen, pastoesen und festen biologischen Reststoffen in elektrische Energie und Asche, bedarfsweise mit Hydrosoft-Hochdruckentwaesserung, Wirbelschicht-Trockner, Wirbelschicht-Vergaser und Produktgas-Kraft-Waerme-Kopplung

    Energy Technology Data Exchange (ETDEWEB)

    Eder, C.; Eder, G. [Christian Eder Technology, Neunkirchen (Germany); Wied, E. [Bisanz GmbH, Saarbruecken (Germany)

    1999-07-01

    By means of the ETVS process, predominantly liquid organic residues can be converted into electrical energy and mineral ash decentrally, i.e. where they accrue. The process is exemplified with reference to sewage sludge. Sludge containing at least about 4 % dry residue is dewatered to the highest dry substance content possible. The obtained filter cakes are indirectly dried in a fluidized-bed drier using internal process waste heat. Then the organic sewage sludge constituents are gasified in an atmospheric fluidized bed system. The cleaned product gas is used to generate power in a cogeneration power plant, meeting the sewage treatment plant's in-house power demand. The ETVS process is self-sufficient in terms of thermal energy requirement from an initial dry substance content of the filter cake > 40 %. Incineration is a means of disposing of sewage sludge in accordance with the boundary conditions for sewage sludge disposal from 2005, laid down in the technical code on municipal waste. Combining the ETVS process with modern biological treatment stages makes for a substantial cut in the construction and operating cost of sewage treatment plants. (orig.) [German] Mit dem ETVS-Verfahren koennen ueberwiegend fluessige biologische Reststoffe dezentral, d.h. an der Anfallstelle in eigennutzbare elektrische Energie und mineralische Asche umgewandelt werden. Das Verfahren wird am Klaerschlamm beispielhaft dargestellt. Der Klaerschlamm wird ab einem Trockensubstanzgehalt von ca. 4%TR auf moeglichst hohe Trockensubstanzgehalte entwaessert und die dabei erzeugten Filterkuchen mit internen Prozessabwaermen in einem Wirbelschichttrockner indirekt getrocknet. Die organischen Bestandteile des Klaerschlammes werden anschliessend in einer ebenfalls atmosphaerischen Wirbelschichtanlage vergast. Der mit dem gereinigten Produktgas in einer KWK-Anlage erzeugte Strom wird zur Deckung des Eigenbedarfs der Klaeranlage verwandt. Durch die Veraschung liefert das ab einem

  15. Response assessment of stereotactic body radiation therapy using dynamic contrast-enhanced integrated MR-PET in non-small cell lung cancer patients.

    Science.gov (United States)

    Huang, Yu-Sen; Chen, Jenny Ling-Yu; Hsu, Feng-Ming; Huang, Jei-Yie; Ko, Wei-Chun; Chen, Yi-Chang; Jaw, Fu-Shan; Yen, Ruoh-Fang; Chang, Yeun-Chung

    2018-01-01

    To evaluate the response in patients undergoing SBRT using dynamic contrast-enhanced (DCE) integrated magnetic resonance positron emission tomography (MR-PET). Stereotactic body radiation therapy (SBRT) is efficacious as a front-line local treatment for non-small cell lung cancer (NSCLC). We prospectively enrolled 19 lung tumors in 17 nonmetastatic NSCLC patients who were receiving SBRT as a primary treatment. They underwent DCE-integrated 3T MR-PET before and 6 weeks after SBRT. The following image parameters were analyzed: tumor size, standardized uptake value (SUV), apparent diffusion coefficient, K trans , k ep , v e , v p , and iAUC 60 . Chest computed tomography (CT) was performed at 3 months after SBRT. SBRT treatment led to tumor changes including significant decreases in the SUV max (-61%, P PET SUV max was correlated with the MR k ep mean (P = 0.002) and k ep SD (P 10 (P = 0.083). In patients with NSCLC who are receiving SBRT, DCE-integrated MR-PET can be used to evaluate the response after SBRT and to predict the local treatment outcome. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:191-199. © 2017 International Society for Magnetic Resonance in Medicine.

  16. MR imaging for staging of cervical carcinoma: Update

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk; Kim, Dong Won [Dong A University Hospital, Busan(Korea, Republic of)

    2017-08-15

    Uterine cervical cancer is globally the third most common cancer among women, and shows high mortality with invasive cervical carcinoma. Early detection of the disease, its correct staging, and treatment are therefore of great importance. The staging system updated in 2009 by the International Federation of Gynecology and Obstetrics (FIGO), is commonly used for planning the treatment. However, there are significant inaccuracies in the FIGO staging system. Accurate tumor staging is very important to decide the treatment strategy. Although not included in the staging system, magnetic resonance (MR) imaging is a valuable tool for local staging of the disease, and is useful in assessing the spread of the tumor and metastatic lymph nodes, thereby becoming a more accurate substitute for clinical staging of cervical carcinoma. In addition, it is capable of assessing the disease response to surgery or chemoradiation. This review briefly describes the role of MR imaging and the basic MR scanning protocol in evaluating cervical carcinoma. The MR findings with staging, and MR evaluation of treatment response, are further addressed.

  17. Wirbelsäulenchirurgische Verfahren und Bedeutung bei osteoporotischen Wirbelkörperfrakturen

    Directory of Open Access Journals (Sweden)

    Teuscher R

    2013-01-01

    Full Text Available Osteoporotische Wirbelbrüche sind häufig. Der Großteil ist gutartig mit einem selbstlimitierenden Verlauf. Allerdings sehen wir in der Wirbelsäulenchirurgie zunehmend auch die Problemfälle: persistierende Instabilität/ Pseudarthrose nach einer Fraktur, der langsam progressive Verlust der Haltung/Wirbelsäulenbalance als Folge mehrerer Wirbelbrüche und schließlich neurologische Komplikationen in Verbindung mit einer osteoporotischen Fraktur. Die Injektion von Knochenzement zur Stabilisierung von Wirbelfrakturen ist effizient und hat sich bewährt. Damit erreicht man eine Stabilisierung des Wirbels und eine sehr wirksame Schmerzkontrolle. Zusätzlich (und häufig zu wenig beachtet können damit ein weiteres Einsintern des Knochens verhindert und Folgekomplikationen so vermieden werden. Wo diese einfache minimalinvasive Technik nicht mehr genügt, sind offene Verfahren notwendig. Auch dabei wird eine kombinierte Technik angewendet: Die Stabilisierung erfolgt nach den gängigen wirbelsäulenchirurgischen Prinzipien, zur Verankerung der Implantate im osteoporotischen Knochen wird ebenfalls Knochenzement verwendet.

  18. Mechanical-biological waste treatment with thermal processing of partial fractions; Mechanisch-biologische Restabfallbehandlung unter Einbindung thermischer Verfahren fuer Teilfraktionen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    Technologies for mechanical-biological treatment of waste in the Land of Hessen were compared including thermal processes like combustion and gasification. The new and more rigid limiting values specified in the Technical Guide for Municipal Waste Treatment (Technische Anleitung Siedlungsabfall - TASI) get a special mention. [Deutsch] Verschiedene Technologien der mechanisch-biologischen Restabfallbehandlung im Raum Hessen wurden unter Einbezug thermischer Verfahren (Verbrennung, Vergasung) miteinander verglichen. Dabei wurden besonders auf die verschaerften Grenzwerte der Technischen Anleitung Siedlungsabfall (TASI) eingegangen. (ABI)

  19. MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC

  20. Imaging techniques for ultrasonic testing; Bildgebende Verfahren fuer die Ultraschallpruefung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    - Klassische Anwendungen und neuere Entwicklungen der Ultraschall-Bildgebung; 3. Innovative abbildende Ultraschallverfahren in der Forschung und Applikation; 4. Industrielle Ultraschallpruefung geometrisch komplexer Faserverbundstrukturen; 5. Visualisierung von Rissspitzen bei der Pruefung von Radsatzwellen mit Laengsbohrung zur Vermeidung unnoetiger Radsatzwechsel; 6. Flaechige Analyse der Ausbreitung von Lamb-Wellen an gekruemmten, anisotropen Strukturen; 7. Hochaufloesende Darstellung bei der Pruefung in Tauchtechnik; 8. Varianten zur Bilderzeugung aus Phased Array Messdaten - Praktische Beispiele an Kupfer, CFK und anderen Materialien; 9. GIUM - ein unkonventionelles Verfahren der Mikrostrukturabbildung mit Ultraschallanregung und laservibrometrischer Abtastung; 10. Innovative Pruefkonzepte im Luftultraschall zur verbesserten Bildgebung; 11. Nutzung von bildgebenden Verfahren zur Verbesserung der zfP-Pruefaussage; 12.Modellierung und Visualisierung der EMUS-Anregung als Hilfsmittel zur Wandleroptimierung; 13. Anwendung von SAFT im Energiemaschinenbau; 14. Bildgebende Ultraschallpruefung zur verbesserten Fehlercharakterisierung bei der Schweissnahtpruefung von laengsnahtgeschweissten Grossrohren; 15. SAFT-Rekonstruktion fuer die Querfehlerpruefung in austenitischen Schweissnaehten und Mischnaehten; 16. Bildgebendes Optimierungsverfahren zur quantitativen US-Pruefung an anisotropen und inhomogenen austenitischen Schweissverbindungen mit Bestimmung und Nutzung der elastischen Eigenschaften. Ein Beitrag wurde separat aufgenommen.

  1. High-field-strength MR imaging of endometriosis

    International Nuclear Information System (INIS)

    Zawin, M.; McCarthy, S.M.; Comite, F.

    1987-01-01

    Twelve women with proven endometriosis were evaluated with MR imaging, utilizing a 1.5-T system. Axial and sagittal T1, proton density, and T2-weighted images were acquired. Laparoscopies were performed within a 1-month interval of the study in all cases. MR imaging accurately identified seven endometriomas but missed lesions in two cases. Areas with endometriotic implants were accurately localized five cases. The authors conclude that MR imaging is extremely useful in identifying sites of endometriosis and, therefore, promises to obviate repeated laparoscopies to monitor patients' response to therapy

  2. MR imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzenbecher, A.; Hamm, B.; Bollow, M. [Humboldt-Universitaet, Berlin (DD). Bereich Medizin (Charite); Braun, J. [Freie Univ. Berlin (Germany). Universitaetsklinikum Benjamin Franklin; Paris, S. [Unfallkrankenhaus Berlin (Germany). Dept. of Radiology; Biedermann, T. [Krankenhaus Berlin-Buch (Germany). II. Kinderklinik

    2000-08-01

    Objective. To investigate the diagnostic value of magnetic resonance (MR) imaging in detecting septic sacroiliitis and to determine whether the MR characteristics allow this entity to be differentiated from sacroiliitis in spondylarthropathy (SpA).Patients and design. The imaging findings of 11 patients with septic sacroiliitis were retrospectively analyzed by two experienced radiologists. Radiographic surveys of the pelvis as well as computed tomography (CT) and MR images of the sacroiliac joints were available in all cases. Seven of the patients additionally underwent a follow-up MR examination. The MR imaging protocol comprised combinations of coronal and transverse T1-weighted spin-echo (SE) or fast SE sequences, T2-weighted gradient-echo (GE) sequences and short tau inversion recovery sequence (STIR) sequences as well as dynamic contrast- enhanced T1-weighted acquisitions.Results. Three patients with a short disease history showed anterior and/or posterior subperiosteal infiltrations (''lava cleft phenomenon''), transcapsular infiltrations of juxta-articular muscle layers, which obscured the fasciae, and periarticular bone marrow edema. The eight patients with more advanced stages of sacroiliitis additionally showed abscess formation, sequestration, and erosion. At follow-up MR examination (n=7) under systemic antibiotic treatment, the morphologic characteristics showed progression (n=1), regression (n=4), unchanged findings (n=1), or a mixed response (n=1). Clinical improvement precedes resolution of the MR findings.Conclusions. Anterior and/or posterior subperiosteal infiltrations and transcapsular infiltrations of juxta-articular muscle layers were depicted in all patients. These MR imaging findings are characteristic of septic sacroiliitis and may be used to differentiate this entity from sacroiliitis in SpA. (orig.)

  3. Modern engine management using neuronal nets; Modernes Motormanagement mit Neuronalen Netzen

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, R O

    1998-07-01

    The author focuses on the theoretical analysis, description and extension of neuronal control technology and its applications in engine management. Definitions and methods are presented for forward and recurrent nets. The fundamentals of control technology are described, and neuronal methods for modelling and control are presented. The first part of the report ends with a stability calculation which leads to the extension of existing learning methods. The second part discusses neuronal methods in the control of an external combustion engine. The investigated engine system is described, the combustion process is analyzed, and the fundamentals of engine management are presented. Ignition point and momentum control are presented as examples to illustrate the applicability of neuronal methods. [German] Das Ziel der vorliegenden Arbeit war die theoretische Aufarbeitung, Darstellung und Erweiterung der neuronalen Regelungstechnik und ihre moegliche Anwendung im Motormanagement. Im grundlagenorientierten Teil wurden zuerst die wichtigsten Definitionen und Verfahren fuer vorwaertsgekoppelte und rekurrente Netze praesentiert. Anschliessend folgte eine kurze Einfuehrung in die Regelungstechnik, bevor ausfuehrlich verschiedene Methoden zur neuronalen Modellierung und Regelung vorgestellt wurden. Der erste Teil der Arbeit endete mit einer Stabilitaetsbetrachtung und einer darauf aufbauenden Erweiterung der bestehenden Lernverfahren. Der zweite Teil beschaeftigte sich mit der Anwendung der neuronalen Methoden in der Steuerung eines Verbrennungsmotors. Zur Motivation wurde das betrachtete System genau beschrieben, die Verbrennung analysiert und die Grundlagen des Motormanagements vorgestellt. Beispielhaft wurden im letzten Kapitel die Zuendzeitpunkt- und die Momentenregelung herausgegriffen und an ihnen die Anwendbarkeit der neuronalen Verfahren aufgezeigt. (orig.)

  4. Experimental investigation of the seismic control of a nonlinear soil-structure system using MR dampers

    International Nuclear Information System (INIS)

    Li, Hui; Wang, Jian

    2011-01-01

    This paper reports the results of an experimental study conducted to demonstrate the feasibility and capability of magnetorheological (MR) dampers commanded by a decentralized control algorithm for seismic control of nonlinear civil structures considering soil-structure interaction (SSI). A two-story reinforced concrete (RC) frame resting in a laminar soil container is employed as the test specimen, and two MR dampers equipped in the first story are used to mitigate the response of this frame subjected to various intensity seismic excitations. A hyperbolic tangent function is used to represent the hysteretic behavior of the MR damper and a decentralized control approach for commanding MR dampers is proposed and implemented in the shaking table tests. Only the response of the first story is feedback for control command calculation of the MR dampers. The results indicate that the MR damper can effectively reduce the response of the soil-structure system, even when the soil-structure system presents complex nonlinear hysteretic behavior. The robustness of the proposed decentralized control algorithm is validated through the shaking table tests on the soil-structure system with large uncertainty. The most interesting findings in this paper are that MR dampers not only mitigate the superstructure response, but also reduce the soil response, pile response and earth pressure on the pile foundation

  5. Value of diffusion-weighted MR imaging in assessing response of neoadjuvant chemo and radiation therapy in locally advanced rectal cancer

    Directory of Open Access Journals (Sweden)

    Rania A. Marouf

    2015-09-01

    Conclusion: The use of additional DWI yields better diagnostic accuracy than does use of conventional MR imaging alone in the evaluation of complete response to neoadjuvant chemo radiotherapy in patients with locally advanced rectal cancer.

  6. Tissue tropisms, infection kinetics, histologic lesions, and antibody response of the MR766 strain of Zika virus in a murine model.

    Science.gov (United States)

    Kawiecki, Anna B; Mayton, E Handly; Dutuze, M Fausta; Goupil, Brad A; Langohr, Ingeborg M; Del Piero, Fabio; Christofferson, Rebecca C

    2017-04-18

    The appearance of severe Zika virus (ZIKV) disease in the most recent outbreak has prompted researchers to respond through the development of tools to quickly characterize transmission and pathology. We describe here another such tool, a mouse model of ZIKV infection and pathogenesis using the MR766 strain of virus that adds to the growing body of knowledge regarding ZIKV kinetics in small animal models. We infected mice with the MR766 strain of ZIKV to determine infection kinetics via serum viremia. We further evaluated infection-induced lesions via histopathology and visualized viral antigen via immunohistochemical labeling. We also investigated the antibody response of recovered animals to both the MR766 and a strain from the current outbreak (PRVABC59). We demonstrate that the IRF3/7 DKO mouse is a susceptible, mostly non-lethal model well suited for the study of infection kinetics, pathological progression, and antibody response. Infected mice presented lesions in tissues that have been associated with ZIKV infection in the human population, such as the eyes, male gonads, and central nervous system. In addition, we demonstrate that infection with the MR766 strain produces cross-neutralizing antibodies to the PRVABC59 strain of the Asian lineage. This model provides an additional tool for future studies into the transmission routes of ZIKV, as well as for the development of antivirals and other therapeutics, and should be included in the growing list of available tools for investigations of ZIKV infection and pathogenesis.

  7. Modern Methodology and Techniques Aimed at Developing the Environmentally Responsible Personality

    Science.gov (United States)

    Ponomarenko, Yelena V.; Zholdasbekova, Bibisara A.; Balabekov, Aidarhan T.; Kenzhebekova, Rabiga I.; Yessaliyev, Aidarbek A.; Larchenkova, Liudmila A.

    2016-01-01

    The article discusses the positive impact of an environmentally responsible individual as the social unit able to live in harmony with the natural world, himself/herself and other people. The purpose of the article is to provide theoretical substantiation of modern teaching methods. The authors considered the experience of philosophy, psychology,…

  8. Neoplastic lesions of the temporomandibular joint (TMJ): diagnosis, differential diagnosis and intervention; Neoplasien des Temporomandibulargelenks (TMG). Diagnostik, Differenzialdiagnostik und Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Abolmaali, N.; Schedel, H.; Bergh, B. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Maeurer, J. [Radiologische Praxis am Prinzregentenplatz, Muenchen (Germany)

    2001-09-01

    Purpose. To evaluate the effectiveness of diagnostic and interventional radiological techniques for neoplastic lesions of the temporomandibular joint (TMJ). Material and methods. Modern diagnosis of the TMJ is based on the clinical use of conventional X-ray techniques, computed tomography (CT), magnetic resonance imaging (MRI) and interventional techniques like biopsies, vascular occlusion and ablation. Results. Conventional X-ray still forms the basic diagnostic procedure applied in open and closed mouth position. CT improves the diagnostic information and serves as the standard diagnostical instrument for cartaliganeous or osseous neoplastic lesions. MRI evaluates soft tissue infiltration in multiplanar techniques and high spatial resolution. Interventional vascular and ablative techniques improve the treatment of neoplastic disorders. (orig.) [German] Zielsetzung. Vorstellung der Wertigkeit bildgebender Verfahren fuer die diagnostische und interventionelle Radiologie des Temporomandibulargelenks (TMG). Material und Methodik. Die moderne Radiologie des TMG basiert auf dem Einsatz der konventionellen Roentgendiagnostik, der Computertomographie (CT) und der Magnetresonanztomographie (MRT), sowie interventioneller Verfahren wie der Biopsie, vaskulaerer Embolisationsverfahren und tumorablativer Verfahren. Ergebnisse. Als Basisdiagnostik dient die konventionelle Diagnostik in offener und geschlossener Mundposition der Erfassung von Funktionsstoerungen sowie ossaerer Destruktionen. Die CT erweitert das diagnostische Spektrum und verbessert die Differenzialdiagnostik fuer ossifizierende Prozesse. Der Einsatz der MRT erlaubt die Erfassung der Weichteilinfiltration sowie der Gelenkstrukturen. Vaskulaere interventionelle Verfahren dienen der praetherapeutischen Okklusion bzw. der palliativen Tumortherapie in Form der okklusiven Embolisation, der Chemoembolisation, oder auch der Tumorablation. (orig.)

  9. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  10. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  11. MR-fluid yield surface determination in disc-type MR rotary brakes

    International Nuclear Information System (INIS)

    Farjoud, Alireza; Vahdati, Nader; Fah, Yap Fook

    2008-01-01

    Magneto-rheological (MR) fluids are currently attracting a great deal of attention because of their unique rheological behavior. Many devices have been designed using MR fluids, and of potential interest here are disc-type MR rotary brakes. The plug flow region in MR devices is defined as the region where the fluid is not flowing. The plug flow region plays an important role in design and analysis of MR devices. In MR dampers, the damping coefficient is a function of the plug thickness. In MR valves, the plug thickness is used to control the flow rate through, and the pressure drop across, the MR valve. A MR clutch is performing at the highest efficiency when the entire MR gap is the plug region. For an MR rotary brake, the highest restraining torque is obtained when the entire gap is the plug region as far as there are no wall slip effects. In this paper, using the Bercovier and Engelman constitutive model, the MR fluid flow in disc-type MR brakes is modeled to determine the plug flow region. The resulting system of equations is solved numerically. It is shown that the existence of a plug flow region in the brake will affect the control torque ratio. Better estimation of the plug flow region results in better estimation of the viscous torque

  12. Synthesis and characterization of magneto-rheological (MR fluids for MR brake application

    Directory of Open Access Journals (Sweden)

    Bhau K. Kumbhar

    2015-09-01

    Full Text Available Magneto rheological (MR fluid technology has been proven for many industrial applications like shock absorbers, actuators, etc. MR fluid is a smart material whose rheological characteristics change rapidly and can be controlled easily in presence of an applied magnetic field. MR brake is a device to transmit torque by the shear stress of MR fluid. However, MR fluids exhibit yield stress of 50–90 kPa. In this research, an effort has been made to synthesize MR fluid sample/s which will typically meet the requirements of MR brake applications. In this study, various electrolytic and carbonyl iron powder based MR fluids have been synthesized by mixing grease as a stabilizer, oleic acid as an antifriction additive and gaur gum powder as a surface coating to reduce agglomeration of the MR fluid. MR fluid samples based on sunflower oil, which is bio-degradable, environmentally friendly and abundantly available have also been synthesized. These MR fluid samples are characterized for determination of magnetic, morphological and rheological properties. This study helps identify most suitable localized MR fluid meant for MR brake application.

  13. Bimodal MR-PET agent for quantitative pH imaging

    Science.gov (United States)

    Frullano, Luca; Catana, Ciprian; Benner, Thomas; Sherry, A. Dean; Caravan, Peter

    2010-01-01

    Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on relaxivity and agent concentration – two unknowns. A bimodal approach, incorporating a positron emitter, solves this problem. Simultaneous positron emission tomography (PET) and MR imaging with the biomodal, pH-responsive MR-PET agent GdDOTA-4AMP-F allows direct determination of both concentration (PET) and T1 (MRI), and hence pH. PMID:20191650

  14. Radiography in construction and combination of other NDT methods; Radiografie im Bauwesen und Kombination anderer ZfP-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Hasenstab, Andreas [Ingenieurbuero Dr. Hasenstab GmbH, Augsburg (Germany); Redmer, B. [Bundesanstalt fuer Materialforschung- und pruefung (BAM), Berlin (Germany)

    2016-05-01

    Radiography is in material examination one of the important research methods. So in the steel and plant construction a variety of studies are carried out. In construction, the dominance is the investigations with radar, ultrasonic echo and so in this contribution especially applications with radiographic methods are discribed. Furthermore the combination with different NDT methods should be presented. In all examples there was a combination of radiography and other non-destructive testing methods. In the first example, there is a combination of radiography with ultrasound echo and drilling resistance to an old oak beam from the St. Mary´s church in Lutherstadt Wittenberg (Germany). Measurements by reinforcement locating and radiography of steel plates in the vault of castle Lustheim near Munich and studies using radar and radiography at a temple in the Pergamon Museum in Berlin round off the examples. [German] Die Radiografie stellt in der Materialuntersuchung eine der bedeutendsten Untersuchungsmethoden dar. So werden im Stahl- und Anlagenbau eine Vielzahl von Untersuchungen durchgefuehrt. Im Bauwesen liegt die Dominanz der Untersuchungen bei den Verfahren Radar, Ultraschallecho und so sollen im folgenden Beitrag vor allem Anwendungsbeispiele mit radiographischen Methoden beschrieben werden. Weiter soll die Kombination unterschiedlicher ZfP-Verfahren dargestellt werden. Bei allen Beispielen kam es zu einer Kombination von Radiografie mit anderen zerstoerungsfreien Pruefverfahren. Im ersten Beispiel kommt es zu einer Kombination von Radiografie mit Ultraschallecho und Bohrwiderstand an einem alten Eichenbalken aus der Marienkirche aus Lutherstadt Wittenberg. Messungen mittels Bewehrungsortung und Radiografie an Stahllaschen im Gewoelbe des Schlosses Lustheim bei Muenchen und Untersuchungen mittels Radar und Radiografie an einem Tempel im Pergamonmuseum in Berlin runden die Beispiele ab.

  15. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system; MRT-gestuetzte Markierung und Stanzbiopsie suspekter Mammalaesionen. Moeglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Horn, L.C. [Inst. fuer Pathologie, Universitaetsklinikum Leipzig (Germany); Leinung, S. [Chirurgische Klinik I, Universitaetsklinikum Leipzig (Germany); Briest, S. [Frauenklinik, Universitaetsklinikum Leipzig (Germany)

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (<10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. Conclusion. Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out in a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy. (orig.) [German] Zielsetzung. In den letzten Jahren wurde eine Vielzahl von Systemen zur praeoperativen Markierung oder Biopsie MRT-suspekter Mammalaesionen vorgestellt. Ziel unserer Untersuchungen war es, Moeglichkeiten solcher Verfahren an einem vertikal offenen 0,5-T-Magneten (SIGNA SP/i, GE Medical Systems) zu entwickeln, zu erproben und in die klinische Routine zu

  16. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR

  17. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  18. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  19. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  20. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  1. Gadolinium-enhanced MR imaging in evaluation of Bell palsy

    International Nuclear Information System (INIS)

    Wang, A.M.; Wesolowski, D.P.; Bojrab, D.I.; Ernstoff, R.M.; Farah, J.

    1989-01-01

    Eight patients with Bell palsy were evaluated with Gd-DTPA (Magnevist)-enhanced MR imaging in a 1.0-T Siemen's Magnetom unit. Axial pre-and postcontrast and coronal postcontrast T1-weighted MR images of facial nerves were studied. Significant unilateral enhancement of the facial nerve within the internal auditory canal, with or without involvement of the geniculate ganglia, was found in six patients. Three of these patients without satisfactory response to medical treatment underwent surgical decompression, with excellent recovery of facial nerve function. The authors believe that gadolinium-enhanced MR imaging is valuable in the evaluation and management of Bell palsy

  2. Christian Responses to Modern Slavery

    OpenAIRE

    Reaves, Jayme

    2007-01-01

    Exhibited at the second Glucksman Memorial Symposium on June 13th 2007 This research project explores the theological and ethical issues around modern slavery and movements to abolish it. Topics include: human trafficking; human rights; racism; theological language and doctrines; Christian ethics, values and social practice.

  3. MR tractography

    International Nuclear Information System (INIS)

    Kinosada, Yasutomi; Okuda, Yasuyuki; Ono, Mototsugu

    1993-01-01

    We developed a new noninvasive technique to visualize the anatomical structure of the nerve fiber system in vivo, and named this technique magnetic resonance (MR) tractography and the acquired image an MR tractogram. MR tractography has two steps. One is to obtain diffusion-weighted images sensitized along axes appropriate for depicting the intended nerve fibers with anisotropic water diffusion MR imaging. The other is to extract the anatomical structure of the nerve fiber system from a series of diffusion-weighted images by the maximum intensity projection method. To examine the clinical usefulness of the proposed technique, many contiguous, thin (3 mm) coronal two-dimensional sections of the brain were acquired sequentially in normal volunteers and selected patients with paralyses, on a 1.5 Tesla MR system (Signa, GE) with an ECG-gated Stejskal-Tanner pulse sequence. The structure of the nerve fiber system of normal volunteers was almost the same as the anatomy. The tractograms of patients with paralyses clearly showed the degeneration of nerve fibers and were correlated with clinical symptoms. MR tractography showed great promise for the study of neuroanatomy and neuroradiology. (author)

  4. Explanatory item response modelling of an abstract reasoning assessment: A case for modern test design

    OpenAIRE

    Helland, Fredrik

    2016-01-01

    Assessment is an integral part of society and education, and for this reason it is important to know what you measure. This thesis is about explanatory item response modelling of an abstract reasoning assessment, with the objective to create a modern test design framework for automatic generation of valid and precalibrated items of abstract reasoning. Modern test design aims to strengthen the connections between the different components of a test, with a stress on strong theory, systematic it...

  5. Advanced MR diagnostic imaging in pediatric glial cell tumors: from morphological to pathophysiological evaluation

    International Nuclear Information System (INIS)

    Balev, B.; Georgiev, R.; Novakova, M.

    2013-01-01

    Full text: Introduction: The conventional MR imaging is important, and in most cases necessary imaging tool for studying the macroscopic structure, for localization and distribution of a glial brain tumor. It is an integral part of the optimal MR protocol, which further comprises a diffusion, perfusion techniques, techniques for the permeability and oxygenation assessment, as well as MR spectroscopy to the metabolism assessment. What you will learn: Glial brain tumors in children - incidence, histology, classification, diagnosis; Nature and principles of MR diffusion, perfusion, techniques for permeability and oxygenation assessment, MR spectroscopy; Contemporary techniques allowing to obtain not only MR morphological information but also to evaluate the tumor the pathophysiology: the cellular atypia, cellularity, tumor neovascularization, oxygen consumption, metabolism, status of the blood-brain barrier. This assessment determines the biological potential of the tumor, treatment options and prognosis. Discussion: The findings from conventional MR examinations, incl. administration of gadolinium contrast agents are associated with the degree of glioma and can be useful for their classification. Taking into account that from 20% to 45 % of the unenhanced supratentorial gliomas are malignant, some low-grade gliomas enhance (ganglioglioma, pilocytic astrocytoma, oligodendroglioma), 9% of malignant gliomas have no contrast enhancement, and in general, the contrast enhancement is not seen as a reliable indicator for the infiltration extent. The contemporary MR techniques improve the assessment of the pathophysiology of the tumor which is relevant to its histology and biological potential. Conclusion: Modern MR techniques besides purely diagnostic advantages (determine the extent and distribution of glioma), enable: differentiation of tumor recurrence from radiation necrosis; identification of optimal locations for biopsy or operative resection; prognosis, planning and

  6. Long-term follow-up after modern radical prostate cancer radiotherapy

    DEFF Research Database (Denmark)

    Sander, Lotte

    that clinical target volumes are up to 30% smaller on MRI delineation compared to computer tomography delineation. The overall aim of the thesis was to explore the use of MRI target planning and a Nicle-Titanium prostate stent as fiducial marker for both MR-CT co-registration and image guided radiotherapy....... radiotherapy is a well established treatment modality for prostate cancer. Accuracy and precision are key words with regard to optimal survival and minimal toxicity in modern radiotherapy and are fundamentals in modern radiotherapy. Modern imaging has improved the ability to define radiotherapy target volumes......A significant increase in the prostate cancer incidence has made prostate cancer a major health problem in recent years. Because of the often but unfortunately not always indolent nature of the disease, over-diagnosis and over-treatment are relevant clinical and ethic dilemmas. External beam...

  7. Proton (1H) MR spectroscopy for routine diagnostic evaluation of brain lesions

    International Nuclear Information System (INIS)

    Burtscher, I.M.; Holtaas, S.; Staahlberg, F.; Univ. Hospital, Lund

    1997-01-01

    Purpose: To describe the introduction and performance of proton MR spectroscopy ( 1 H-MRS) in the daily routine of a modern standard MR unit. Material and Methods: Over an 8-month period, 52 patients with brain lesions were studied with 1 H-MRS, using SE and STEAM sequences for chemical-shift imaging and single-volume spectroscopy. The quality of the spectra was graded from 1 (best) to 3, and the main factors influencing the quality of the spectra were evaluated. Results: Of the measurements: 85% were graded as 1; 12% as 2; and 3% as 3. The main reasons for poor spectral quality were: the unfortunate positioning of the VOI; hemorrhage; and/or postoperative changes within the VOI. Of 40 patients with a final diagnosis: MRS provided an increased confidence in MR diagnosis in 18 cases; MRS contributed significantly to preoperative diagnosis in 3 cases; and the spectra were not specific (n=10) or were difficult to evaluate (n=9) owing to reduced quality (grade 2 or 3) in 19 cases. Conclusion: MRS of the brain can provide a high percentage of interpretable spectra and frequently can increase confidence in the MR diagnosis of brain lesions in clinical routine. (orig.)

  8. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  9. Quantitative MR imaging in fracture dating--Initial results.

    Science.gov (United States)

    Baron, Katharina; Neumayer, Bernhard; Widek, Thomas; Schick, Fritz; Scheicher, Sylvia; Hassler, Eva; Scheurer, Eva

    2016-04-01

    For exact age determinations of bone fractures in a forensic context (e.g. in cases of child abuse) improved knowledge of the time course of the healing process and use of non-invasive modern imaging technology is of high importance. To date, fracture dating is based on radiographic methods by determining the callus status and thereby relying on an expert's experience. As a novel approach, this study aims to investigate the applicability of magnetic resonance imaging (MRI) for bone fracture dating by systematically investigating time-resolved changes in quantitative MR characteristics after a fracture event. Prior to investigating fracture healing in children, adults were examined for this study in order to test the methodology for this application. Altogether, 31 MR examinations in 17 subjects (♀: 11 ♂: 6; median age 34 ± 15 y, scanned 1-5 times over a period of up to 200 days after the fracture event) were performed on a clinical 3T MR scanner (TimTrio, Siemens AG, Germany). All subjects were treated conservatively for a fracture in either a long bone or in the collar bone. Both, qualitative and quantitative MR measurements were performed in all subjects. MR sequences for a quantitative measurement of relaxation times T1 and T2 in the fracture gap and musculature were applied. Maps of quantitative MR parameters T1, T2, and magnetisation transfer ratio (MTR) were calculated and evaluated by investigating changes over time in the fractured area by defined ROIs. Additionally, muscle areas were examined as reference regions to validate this approach. Quantitative evaluation of 23 MR data sets (12 test subjects, ♀: 7 ♂: 5) showed an initial peak in T1 values in the fractured area (T1=1895 ± 607 ms), which decreased over time to a value of 1094 ± 182 ms (200 days after the fracture event). T2 values also peaked for early-stage fractures (T2=115 ± 80 ms) and decreased to 73 ± 33 ms within 21 days after the fracture event. After that time point, no

  10. Automatic multi-modal MR tissue classification for the assessment of response to bevacizumab in patients with glioblastoma

    International Nuclear Information System (INIS)

    Liberman, Gilad; Louzoun, Yoram; Aizenstein, Orna; Blumenthal, Deborah T.; Bokstein, Felix; Palmon, Mika; Corn, Benjamin W.; Ben Bashat, Dafna

    2013-01-01

    Background: Current methods for evaluation of treatment response in glioblastoma are inaccurate, limited and time-consuming. This study aimed to develop a multi-modal MRI automatic classification method to improve accuracy and efficiency of treatment response assessment in patients with recurrent glioblastoma (GB). Materials and methods: A modification of the k-Nearest-Neighbors (kNN) classification method was developed and applied to 59 longitudinal MR data sets of 13 patients with recurrent GB undergoing bevacizumab (anti-angiogenic) therapy. Changes in the enhancing tumor volume were assessed using the proposed method and compared with Macdonald's criteria and with manual volumetric measurements. The edema-like area was further subclassified into peri- and non-peri-tumoral edema, using both the kNN method and an unsupervised method, to monitor longitudinal changes. Results: Automatic classification using the modified kNN method was applicable in all scans, even when the tumors were infiltrative with unclear borders. The enhancing tumor volume obtained using the automatic method was highly correlated with manual measurements (N = 33, r = 0.96, p < 0.0001), while standard radiographic assessment based on Macdonald's criteria matched manual delineation and automatic results in only 68% of cases. A graded pattern of tumor infiltration within the edema-like area was revealed by both automatic methods, showing high agreement. All classification results were confirmed by a senior neuro-radiologist and validated using MR spectroscopy. Conclusion: This study emphasizes the important role of automatic tools based on a multi-modal view of the tissue in monitoring therapy response in patients with high grade gliomas specifically under anti-angiogenic therapy

  11. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  12. Regional Ventilation Changes in the Lung: Treatment Response Mapping by Using Hyperpolarized Gas MR Imaging as a Quantitative Biomarker.

    Science.gov (United States)

    Horn, Felix C; Marshall, Helen; Collier, Guilhem J; Kay, Richard; Siddiqui, Salman; Brightling, Christopher E; Parra-Robles, Juan; Wild, Jim M

    2017-09-01

    Purpose To assess the magnitude of regional response to respiratory therapeutic agents in the lungs by using treatment response mapping (TRM) with hyperpolarized gas magnetic resonance (MR) imaging. TRM was used to quantify regional physiologic response in adults with asthma who underwent a bronchodilator challenge. Materials and Methods This study was approved by the national research ethics committee and was performed with informed consent. Imaging was performed in 20 adult patients with asthma by using hyperpolarized helium 3 ( 3 He) ventilation MR imaging. Two sets of baseline images were acquired before inhalation of a bronchodilating agent (salbutamol 400 μg), and one set was acquired after. All images were registered for voxelwise comparison. Regional treatment response, ΔR(r), was calculated as the difference in regional gas distribution (R[r] = ratio of inhaled gas to total volume of a voxel when normalized for lung inflation volume) before and after intervention. A voxelwise activation threshold from the variability of the baseline images was applied to ΔR(r) maps. The summed global treatment response map (ΔR net ) was then used as a global lung index for comparison with metrics of bronchodilator response measured by using spirometry and the global imaging metric percentage ventilated volume (%VV). Results ΔR net showed significant correlation (P treatment effect was detected with all metrics; however, ΔR net showed a lower intersubject coefficient of variation (64%) than all of the other tests (coefficient of variation, ≥99%). Conclusion TRM provides regional quantitative information on changes in inhaled gas ventilation in response to therapy. This method could be used as a sensitive regional outcome metric for novel respiratory interventions. © RSNA, 2017 Online supplemental material is available for this article.

  13. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. MR imaging of muscle diseases

    International Nuclear Information System (INIS)

    Kaiser, W.A.; Zeitler, E.; Schalke, B.C.G.

    1986-01-01

    Because of high soft-tissue contrast, MR imaging is especially suitable for the investigation of muscle diseases. Between March 1984 and March 1986, 76 patients with different types of muscle diseases were examined using a 1-T superconductive magnet (Siemens Magnetom). Studied were 14 patients with progressive muscular dystrophy (including carriers), 32 patients with myositis, four patients with myotonic dystrophy, six patients with spinal muscular atrophy, and 20 patients with other muscle diseases, including metabolic disorders. MR imaging showed typical signal patterns in affected muscle groups. These patterns can be used in the differential diagnosis, in biopsy planning, or in evaluation of response to therapy. The T1/T2 ratio especially seems to indicate very early stages of muscle disease

  15. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  16. Proton-MR-spectroscopy of vertebral bone marrow: normal age- and sex-related patterns; Protonen-MR-Spektroskopie des Wirbelkoerpermarks. Analyse des physiologischen Signalverhaltens

    Energy Technology Data Exchange (ETDEWEB)

    Jung, C.M.; Kugel, H.; Schulte, O.; Heindel, W. [Koeln Univ. (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    2000-08-01

    Background. Magnetic resonance imaging has shown to be a sensitive method for diagnostics of the red bone marrow, the composition of which changes physiologically and during pathological processes. However, the interpretation of MRI in patients with disorders of the red bone marrow is very difficult. The aim of this study was the characterization of the proton spectrum of healthy bone marrow and its age- and sex-dependent changes to obtain a data basis for measurements in patients. Methods. 154 healthy volunteers have been examined. After imaging, a spectroscopic measurement was performed to determine the relative intensities of fat and water, and their respective T2 times. Results. While T2 (water: 46.9 ms and fat: 75.4 ms) does not depend on age or sex, the relative signal intensity of fat increases by about 6% per decade. In the age groups between 31 and 50 years it diverses significantly between men (43.5%) and woman (32.5%) (p{<=}0.01, Mann-Whitney-Test). Conclusions. Proton spectroscopy can increase the reliability of diagnosis by offering information on composition of the marrow. The analysis of spectroscopic measurements requires exact knowledge about normal physiological values. (orig.) [German] Hintergrund. Die Magnetresonanztomographie ist ein sensitives bildgebendes Verfahren zur Beurteilung des roten Knochenmarkraums. Die Zusammensetzung des Knochenmarks aendert sich mit zunehmenden Alter, aber auch bei krankhaften Prozessen. Als Basis fuer die Interpretation von Patientenuntersuchungen bei Erkrankungen des haematopoetischen Systems wurden im Rahmen der vorliegenden Studie an Probanden die alters- und geschlechtsabhaengigen Veraenderungen des Protoenenspektrums aus dem Knochenmarkraum analysiert. Methode. Bei 154 gesunden Probanden wurde nach einer MR-Bildgebung eine spektroskopische Messung des Lendenwirbelkoerpermarks zur Bestimmung der relativen Fett- und Wasseranteile sowie der T2-Relaxationszeiten durchgefuehrt. Ergebnis. Die T2-Zeiten (46,9 ms

  17. Student and Teacher Responses to Prayer at a Modern Orthodox Jewish High School

    Science.gov (United States)

    Lehmann, Devra

    2010-01-01

    This article presents the attitudes of students and teachers to prayer at an American Modern Orthodox Jewish high school. Relevant data, based on observation and interviews, emerged from a larger study of the school's Jewish and secular worlds. A significant gap in responses became apparent. Students viewed prayer as a challenge to their autonomy,…

  18. Development of a method for influencing the nutrient content ofs stabilised sewage sludge by further treatment. Final report; Entwicklung eines Verfahrens zur Beeinflussung der Naehrstoffgehalte bei der weitergehenden Behandlung von stabilisierten Klaerschlaemmen. Verfahren der Aerob-Anoxischen Nachbehandlung - AAN-Verfahren. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Voigtlaender, G.; Lopp, M.

    2002-11-01

    -N-Rueckbelastungen in die KA um etwa 70% reduziert, waehrend sich die N-Frachten im entwaesserten Klaerschlamm um etwa 45% vermindern. Die Trockensubstanzgehalte im Klaerschlamm werden durch weiteren Abbau organischer Verbindungen um 20...25% reduziert. Dies kommt einer aequivalenten Mengenreduzierung des entwaesserten Klaerschlammes gleich. Die Entwaesserungseigenschaften des Schlammes werden deutlich verbessert. Vor allem die erhoehte Trennschaerfe und somit die verbesserte Schlammwasserqualitaet bedeutet im praktischen Einsatz eine Einsparung an Betriebskosten fuer Chemikalien (z.B. Polyelektrolyt). Tests in der Kammerfilterpresse und Flockungstest zeigten ebenfalls verbesserte Entwaesserungseigenschaften. Weiterhin ist festzustellen: Die Moeglichkeit der Faulzeitverkuerzung (ca. 15 d) bringt weitere Einsparpotentiale im Bereich der Schlammfaulung. Die zusaetzliche Rueckbelastungsreduzierung in Bezug auf P und schwer abbaubaren CSB entlastet die KA. Die Kombination mit der Klaerschlammdesintegration kommt vor allem bei sehr kurzen Faulzeiten (ca. 10 d) zum Tragen. Die Erprobung des Verfahrens fuer simultan aerob stabilisierte Schlaemme fuehrte, auch in Kombination mit der Klaerschlammdesintegration, nur zu Stickstoffreduzierungen von bis zu 15% und blieb damit unter den Erwartungen. Insgesamt laesst sich feststellen, dass das Projekt inhaltlich erfolgreich abgeschlossen wurde, dass die Ergebnisse in Bezug auf die Hauptzielrichtungen ausserordentlich positiv ausfielen und das der vorgesehene Kostenrahmen eingehalten wurde. Die Reduzierung der Stickstoffgehalte wird in absehbarer Zeit vorrangig der landschaftsbaulichen Verwertung zugute kommen. Insbesondere die Kombination der genannten Effekte macht das Verfahren fuer die praktische Anwendung interessant. (orig.)

  19. 2D-FE throughflow method for multistage cooled turbines with subsonic and transonic flow. Final report; 2D-FE-Verfahren fuer die Kennfeldberechnung von vielstufigen Turbinen mit unter- und ueberkritischen Stufendruckverhaeltnissen mit variabler Kuehlluftzufuhr. Abschlussbericht zum Vorhaben 1.312

    Energy Technology Data Exchange (ETDEWEB)

    Riess, W.; Gehring, S.

    2000-07-01

    ] Meridianstroemungsverfahren werden aufgrund ihres geringen Bedarfs an Rechenzeit zur schnellen Simulation des Betriebsverhaltens von Turbomaschinen eingesetzt. Um dieser Aufgabe bei der Auslegung des Turbinenteils einer Gasturbine gerecht zu werden, muessen die Verfahren sowohl alle wesentlichen stroemungsmechanischen Einfluesse als auch die Einfluesse moderner Systeme zur Bauteilkuehlung beruecksichtigen. Die vorliegende Arbeit befasst sich mit der Modellierung von Sekundaerstroemungseinfluessen, radialen Transportprozessen und Kuehlungseinfluessen in einem auf der Methode der Finiten-Elemente basierenden Meridianstroemungsverfahren. Zur Beruecksichtigung der Einfluesse komplexer Kuehlungssysteme koennen beliebige Konfigurationen von konvektiver Kuehlung, Ausblasung an den Schaufelhinterkanten, Filmkuehlung sowie Ausblasung an Nabe und Gehaeuse vorgegeben werden. Der Mischungsprozess zwischen Hauptmassenstrom und Kuehlluft wird mit Hilfe vereinfachter Bilanzgleichungen berechnet. Massenstromaenderungen werden entweder durch Aenderung der Definitionsgleichungen der Stromfunktion oder im Fall von Ausblasungen in den Randzonen durch geaenderte Randbedingungen an den Seitenwaenden beruecksichtigt. Um bei einem vorgegebenen Druckverhaeltnis den Massenstrom berechnen zu koennen, wird eine Druckregelung implementiert. Die Druckregelung passt den Massenstrom waehrend der Berechnung an das geforderte Druckverhaeltnis an. Die Kontinuitaetsgleichung ist zu jedem Zeitpunkt der Berechnung erfuellt, wodurch die Rechnung beschleunigt wird. Zur Ueberpruefung des Verfahrens wird eine 1,5-stufige Versuchsturbine mit lokaler Kuehlgasausblasung vor der Beschaufelung sowie der Turbinenteil der Hochtemperatur-Gasturbine V84.3 der Firma Siemens AG (KWU) nachgerechnet. Die Hochtemperatur-Gasturbine wird durch eine Kombination von Konvektionskuehlung und Hinterkantenausblasung gekuehlt. Die berechneten Stroemungsgroessen zeigen fuer beide Maschinen eine gute Uebereinstimmung mit experimentellen Daten bzw

  20. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  1. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  2. MR imaging of soft tissue tumors and tumor-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Laor, Tal [Department of Radiology, Cincinnati Children' s Hospital Medical Center, 3333 Burnet Avenue, 45229, Cincinnati, OH (United States)

    2004-01-01

    The evaluation of a soft tissue mass in a child should proceed with a differential diagnosis in mind, based on the clinical history, age of the child, and location of the abnormality. Small, superficial masses can be initially evaluated with sonography. More extensive or deep lesions usually require cross-sectional imaging. With the exception of myositis ossificans, magnetic resonance (MR) imaging has largely replaced the use of computed tomography. MR imaging is used to delineate the extent of a lesion, to evaluate response to therapy, and to monitor postoperative complications. There is great overlap in the MR imaging characteristics of benign and malignant lesions, making tissue sampling imperative for diagnosis. (orig.)

  3. Effect of transurethral microwave thermotherapy. An evaluation with MR imaging

    International Nuclear Information System (INIS)

    Nordenstam, G.; Aspelin, P.; Isberg, B.; Svensson, L.; Hallin, A.; Berlin, T.

    1996-01-01

    Purpose: To detect morphological changes in the prostate, as depicted with MR imaging, in order to clarify the effects of transurethral microwave thermotherapy (TUMT). Material and Methods: Twenty patients with prostatism and a prostatic volume of 30-71 cm 3 underwent MR examination before, the day after, and 6 months after treatment. TUMT was carried out with a Prostatron. A method to detect oedematous changes on heavily T2-weighted MR images was developed and used as an indicator of morphological changes. Results: The study showed some correlation (r=0.59) between the energy given at TUMT and an increased T2 signal. All patients with increased T2 signal except one were found among those who received the highest amount of energy to the prostate. Of 8 patients, 6 showed a symptomatic response to the treatment and 2 did not. There was a weak statistical correlation (r=0.41) between treatment response and increased T2 signal. Conclusion: The study does not support the view that TUMT leads to significant necrosis in the prostate with loss of tissue and retraction. We theorize that the response to TUMT may be caused by a denervation of the prostate. (orig.)

  4. Interventional MR: vascular applications.

    Science.gov (United States)

    Smits, H F; Bos, C; van der Weide, R; Bakker, C J

    1999-01-01

    Three strategies for visualisation of MR-dedicated guidewires and catheters have been proposed, namely active tracking, the technique of locally induced field inhomogeneity and passive susceptibility-based tracking. In this article the pros and cons of these techniques are discussed, including the development of MR-dedicated guidewires and catheters, scan techniques, post-processing tools, and display facilities for MR tracking. Finally, some of the results obtained with MR tracking are discussed.

  5. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  6. MR anatomy of the joints: an MR-cadaveric correlative study: part I. wrist

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Heung Sik [Seoul National University College of Medicine, Seoul (Korea, Republic of); Donald Resnick [University of California, San Diego (United States)

    1991-07-15

    To acquire the anatomic information necessary for correct interpretation of MR images of the wrist, transverse, coronal, and sagittal MR images of 3 fresh cadaveric wrists were obtained and, subsequently, sectioned along the MR imaging planes. For the precise correlation of anatomic features depicted with MR and with specimen section, cadaveric wrists were fixed in a rectangular cardboard box using paraffin and frozen after MR imaging. High contrast and spatial resolution enabled delineation of small structures including tendons, nerves, vessels, and ligaments, as well as osseous structures. Transverse images provided the best delineation of the carpal tunnel, tendons, nerves, and vessels. Coronal images permitted optimal visualization of triangular fibrocartilage and lunotriquetral and scapholunate ligaments. We conclude that MR imaging accurately and reliably displays the anatomy of the wrist.

  7. PET/MR in oncology: an introduction with focus on MR and future perspectives for hybrid imaging

    Science.gov (United States)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin; Zamogilnaya, Yanna; Højgaard, Liselotte; Fischer, Barbara M

    2012-01-01

    After more than 20 years of research, a fully integrated PET/MR scanner was launched in 2010 enabling simultaneous acquisition of PET and MR imaging. Currently, no clinical indication for combined PET/MR has been established, however the expectations are high. In this paper we will discuss some of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number of different MRI techniques, such as DWI-MR (diffusion weighted imaging MR), DCE-MR (dynamic contrast enhanced MR), MRS (MR spectroscopy) and MR for attenuation correction of PET. All MR techniques presented in this paper have shown promising results in the treatment of patients with solid tumors and could be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new tracers and drugs will be discussed. PMID:23145362

  8. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  9. MR and MR arthrography to identify degenerative and posttraumatic diseases in the shoulder joint

    International Nuclear Information System (INIS)

    Lee, Shi-Uk; Lang, Philipp

    2000-01-01

    MR imaging provides a comprehensive evaluation of a wide spectrum of both intraarticular and extraarticular pathology of the shoulder. MR imaging enables the detection or exclusion of degenerative and posttraumatic diseases of the shoulder with a reasonable accuracy. MR arthrography is useful in the visualization of subtle anatomic details and further improves the differentiation. In this article, findings of MR imaging and MR arthrography of degenerative and posttraumatic shoulder diseases (impingement syndrome, rotator cuff tears, and glenohumeral instability) has been reviewed

  10. Study on the development of passive MR damper with displacement-dependent damping characteristics

    International Nuclear Information System (INIS)

    Murakami, Takahiro; Sakai, Michiya; Nakano, Masami

    2010-01-01

    In this paper, we propose a new concept of a magneto-rheological (MR) fluid damper, which is a passive MR fluid damper. The passive MR damper has no electrical devices, such as a sensor, power supply and controller, and hence, it has an advantage in reliability and cost compared with semi-active MR dampers. Moreover, the proposed MR damper can be designed to have a variable damping force in response to its displacement. In this paper, the dynamic performance of the passive MR damper is experimentally demonstrated. The prototype of the proposed damper has been manufactured in order to verify the dynamic performance. The displacement excitation test result of the damper demonstrates that the damping characteristics depend on its displacement amplitude, that is, the damper behaves as a linear viscous damper under small vibrations and develops much higher damping performance under large vibrations. (author)

  11. MR evaluation of CSF fistulae

    International Nuclear Information System (INIS)

    Gupta, V.; Goyal, M.; Mishra, N.; Gaikwad, S.; Sharma, A.

    1997-01-01

    Purpose: To evaluate the role of MR imaging in the localisation of cerebrospinal fluid (CSF) fistulae. Material and Methods: A total of 36 consecutive unselected patients with either clincally proven CSF leakage (n=26) or suspected CSF fistula (n=10) were prospectively evaluated by MR. All MR examinations included fast spin-echo T2-weighted images in the 3 orthogonal planes. Thin-section CT was performed following equivocal or negative MR examination. MR and CT findings were correlated with surgical results in 33 patients. Results: CSF fistula was visualised as a dural-bone defect with hyperintense fluid signal continuous with that in the basal cisterns on T2-weighted images. MR was positive in 26 cases, in 24 of which the fistula was confirmed surgically. In 2 patients the CSF leakage was directly demonstrated on MR. MR sensitivity of 80% compared favourably with the reported 46-81% of CT cisternography (CTC). No significant difference in MR sensitivity in detecting CSF fistula was found between active and inactive leaks. (orig.)

  12. Contrast-Enhanced MR Imaging of Lymph Nodes in Cancer Patients

    International Nuclear Information System (INIS)

    Choi, Seung Hong; Moon, Woo Kyung

    2010-01-01

    The accurate identification and characterization of lymph nodes by modern imaging modalities has important therapeutic and prognostic significance for patients with newly diagnosed cancers. The presence of nodal metastases limits the therapeutic options, and it generally indicates a worse prognosis for the patients with nodal metastases. Yet anatomic imaging (CT and MR imaging) is of limited value for depicting small metastatic deposits in normal-sized nodes, and nodal size is a poor criterion when there is no extracapsular extension or focal nodal necrosis to rely on for diagnosing nodal metastases. Thus, there is a need for functional methods that can be reliably used to identify small metastases. Contrast-enhanced MR imaging of lymph nodes is a non-invasive method for the analysis of the lymphatic system after the interstitial or intravenous administration of contrast media. Moreover, some lymphotrophic contrast media have been developed and used for detecting lymph node metastases, and this detection is independent of the nodal size. This article will review the basic principles, the imaging protocols, the interpretation and the accuracies of contrast-enhanced MR imaging of lymph nodes in patients with malignancies, and we also focus on the recent issues cited in the literature. In addition, we discuss the results of several pre-clinical studies and animal studies that were conducted in our institution

  13. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  14. Normal anatomy and MR findings of fetal main organs at MR imaging

    International Nuclear Information System (INIS)

    Xia Liming; Zou Mingli; Feng Dingyi; Hu Junwu; Qi Jianpin; Wang Chengyuan

    2005-01-01

    Objective: To investigate normal anatomy and MR findings of fetal main organs. Methods: Forty-seven fetus underwented fast MR imaging, SSFSE sequence was used, the normal anatomy and MR findings of fetal main organs was observed in different gestational age. The organs included: brain, lungs, heart, liver, spleen, gastrointestinal tract, urinary collecting systems, bladder, bones, spine, and subcutaneous fat. Results: Results of MR in 47 fetus showed that the main organs had developed by 20-week-old fetus, about 20 weeks gestation, cerebral cortical surface was smooth, no cortical gyri and sulci, then cortical gyri and sulci developed slowly. The lungs, trachea, bronchus, gastrointestinal tract, renal collecting system and bladder showed high signal intensity; the heart, great vessels, liver, spleen, bones and muscles appeared hypointense; the kidneys appeared isointense, the spine had developed and subcutaneous fat was seen in 20-week-old fetus, the subcutaneous fat increased with fetus maturating. Conclusion: Normal anatomy and MR findings of fetal main organs were clearly showed by fast MR imaging, and they are different from the newborns. (authors)

  15. MR imaging of articular cartilage; Gelenkknorpel in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, F.K.W.; Muhle, C.; Heller, M.; Brossmann, J. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2001-04-01

    MR imaging has evolved to the best non-invasive method for the evaluation of articular cartilage. MR imaging helps to understand the structure and physiology of cartilage, and to diagnose cartilage lesions. Numerous studies have shown high accuracy and reliability concerning detection of cartilage lesions and early changes in both structure and biochemistry. High contrast-to-noise ratio and high spatial resolution are essential for analysis of articular cartilage. Fat-suppressed 3D-T{sub 1} weighted gradient echo and T{sub 2}-weighted fast spin echo sequences with or without fat suppression are recommended for clinical routine. In this article the anatomy and pathology of hyaline articular cartilage and the complex imaging characteristics of hyaline cartilage will be discussed. (orig.) [German] Die MR-Tomographie hat sich zur besten nichtinvasiven bildgebenden Methode fuer die Untersuchung von Gelenkknorpel entwickelt. Die MR-Tomographie liefert einen Beitrag zum Verstaendnis der Knorpelstruktur und der Physiologie sowie zur Diagnostik von Knorpelschaeden. Zahlreiche MR-Studien konnten eine hohe Genauigkeit und Zuverlaessigkeit bei der Detektion chondraler Laesionen sowie frueher Veraenderungen struktureller und biochemischer Natur zeigen. Neben einem hohen Kontrast/Rausch-Verhaeltnis ist fuer die Gelenkknorpelanalyse eine hohe raeumliche Aufloesung erforderlich. Im klinischen Routinebetrieb empfehlen sich fuer die Erkennung von Knorpellaesionen besonders fettunterdrueckte 3D-T{sub 1}-gewichtete Gradientenecho- und T{sub 2}-gewichtete Fastspinecho-Sequenzen mit oder ohne Fettunterdrueckung. Die vorliegende Arbeit geht auf die Anatomie und Pathologie des hyalinen Gelenkknorpels ein und diskutiert das komplexe MR-Signalverhalten. (orig.)

  16. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California-San Diego, Department of Radiology, San Diego, CA (United States); Ruangchaijatuporn, Thumanoon [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Rachathewi, Bangkok (Thailand); Biswas, Reni; Du, Jiang; Statum, Sheronda [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2016-04-15

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  17. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    International Nuclear Information System (INIS)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B.; Ruangchaijatuporn, Thumanoon; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  18. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties.

    Science.gov (United States)

    Bae, Won C; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda; Chung, Christine B

    2016-04-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques.

  19. MR imaging and histopathologic correlations of thermal injuries induced by interstitial laser applications

    International Nuclear Information System (INIS)

    Anzai, Y.; Lufkin, R.B.; Castro, D.J.; Farahani, K.; Chen, H.W.; Hirchowiz, S.

    1991-01-01

    Interstitial laser phototherapy for deep-seated tumors may become an attractive therapeutic modality when a noninvasive, accurate monitoring system is developed. In this paper, to devaluate the ability of MR imaging to differentiate reversible and irreversible thermal injuries induced by laser therapy, the precise correlation of MR and histopathologic findings are investigated in the in vivo model. Nd:YAG lasers were applied to normal musculature of rabbits, and MR examinations were performed immediately after laser exposure and followed up for up to 10 weeks. The sequential MR images were correlated with histopathologic findings. T2-weighted MR imaging clearly showed laser-induced thermal injuries on any postoperative day. MR imaging of acute thermal injuries showed a central cavity, low-signal zone of coagulative necrosis and a peripheral high-signal layer of interstitial edema. The infiltration of neutrophils followed by fibrovascular response was identified on the marginal edema layer after 6 postoperative days

  20. Vibration control of an MR vehicle suspension system considering both hysteretic behavior and parameter variation

    International Nuclear Information System (INIS)

    Choi, Seung-Bok; Seong, Min-Sang; Ha, Sung-Hoon

    2009-01-01

    This paper presents vibration control responses of a controllable magnetorheological (MR) suspension system considering the two most important characteristics of the system; the field-dependent hysteretic behavior of the MR damper and the parameter variation of the suspension. In order to achieve this goal, a cylindrical MR damper which is applicable to a middle-sized passenger car is designed and manufactured. After verifying the damping force controllability, the field-dependent hysteretic behavior of the MR damper is identified using the Preisach hysteresis model. The full-vehicle suspension model is then derived by considering vertical, pitch and roll motions. An H ∞ controller is designed by treating the sprung mass of the vehicle as a parameter variation and integrating it with the hysteretic compensator which produces additional control input. In order to demonstrate the effectiveness and robustness of the proposed control system, the hardware-in-the-loop simulation (HILS) methodology is adopted by integrating the suspension model with the proposed MR damper. Vibration control responses of the vehicle suspension system such as vertical acceleration are evaluated under both bump and random road conditions

  1. MR imaging of normal bone marrow; Obraz MR prawidlowego szpiku kostnego

    Energy Technology Data Exchange (ETDEWEB)

    Stajgis, M.; Paprzycki, W. [Osrodek Diagnostyki Obrazowej IR, Akademia Medyczna, Poznan (Poland)

    1994-12-31

    Principles of MR bone marrow imaging on the basis of retrospective analysis of MR examinations of bone marrow in different anatomic sites in 200 patients have been discussed. Significance of different physiologic factors and processes such as age, steatosis, osteoporosis, conversion and reconversion, which influence on MR bone marrow images, have been emphasized. T1-weighted images obtained with spin-echo sequences give the most of information about bone marrow structure in MR. Thorough knowledge of bone marrow physiology and clinical status of the patient is indispensable in correct interpretation of hypointensive lesions on T1-weighted images. When presence of disseminated bone marrow disease is suspected, authors propose routine imaging of lumbar vertebral column, pelvis and proximal parts of femoral bones. (author) 7 refs, 7 figs

  2. MR imaging of rhabdomyolysis

    International Nuclear Information System (INIS)

    Zagoria, R.J.; Karstaedt, N.; Koubek, T.D.

    1986-01-01

    The use of magnetic resonance (MR) imaging in two cases of rhabdomyolysis, one resulting from prolonged muscle compression and one from electrical burns, is described. The involved muscles were clearly demonstrated with MR. Recognition and assessment of the extent of rhabdomyolysis are important since life-threatening sequelae including severe metabolic disorders are possible. In one case, spin-echo and inversion-recovery MR imaging provided greater detail of muscle abnormalities than did 99mTc-pyrophosphate radionuclide scanning. Both cases illustrate the usefulness of MR in evaluation of skeletal muscle disorders

  3. Contribution of abdoscan using MR cholangio-pancreatography and MR urography

    International Nuclear Information System (INIS)

    Lecesne, R.; Drouillard, J.; Cisse, R.; Schiratti, M.

    1998-01-01

    MR cholangio-pancreatography (MRCP) and MR Urography (MRU) are promising recent imaging modalities. Oral magnetic particles (Abdoscan, Nycomed SA, Oslo, Norway) is an negative contrast agent eliminating signal intensity of the gastro-intestinal tract thus improvising image quality at MRCP and MRU. (author)

  4. Imaging of the lumbosacral plexus. Diagnostics and treatment planning with high-resolution procedures; Bildgebung des Plexus lumbosacralis. Diagnostik und Therapieplanung mithilfe hochaufgeloester Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Jengojan, S.; Schellen, C.; Bodner, G.; Kasprian, G. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2017-03-15

    Technical advances in magnetic resonance (MR) and ultrasound-based neurography nowadays facilitate the radiological assessment of the lumbosacral plexus. Anatomy and imaging of the lumbosacral plexus and diagnostics of the most common pathologies. Description of the clinically feasible combination of magnetic resonance imaging (MRI) and ultrasound diagnostics, case-based illustration of imaging techniques and individual advantages of MRI and ultrasound-based diagnostics for various pathologies of the lumbosacral plexus and its peripheral nerves. High-resolution ultrasound-based neurography (HRUS) is particularly valuable for the assessment of superficial structures of the lumbosacral plexus. Depending on the examiner's experience, anatomical variations of the sciatic nerve (e. g. relevant in piriformis syndrome) as well as more subtle variations, for example as seen in neuritis, can be sonographically depicted and assessed. The use of MRI enables the diagnostic evaluation of more deeply located nerve structures, such as the pudendal and the femoral nerves. Modern MRI techniques, such as peripheral nerve tractography allow three-dimensional depiction of the spatial relationship between nerves and local tumors or traumatic alterations. This can be beneficial for further therapy planning. The anatomy and pathology of the lumbosacral plexus can be reliably imaged by the meaningful combination of MRI and ultrasound-based high resolution neurography. (orig.) [German] Durch technische Fortschritte im Bereich der magnetresonanz- (MR-) und ultraschallbasierten Neurographie ist der Plexus lumbosacralis heute der radiologischen Abklaerung zugaenglich. Anatomie und Bildgebung des Plexus lumbosacralis, Abklaerung der haeufigsten Pathologien. Erlaeuterung der klinisch sinnvollen Kombination von MR- und Ultraschalldiagnostik, Darstellung der Untersuchungstechniken und der jeweiligen Vorteile von MRT und Ultraschall anhand fallbasierter Praesentation unterschiedlicher

  5. MR imaging and MR angiography in popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Atilla, S.; Akpek, S.; Yuecel, C.; Tali, E.T.; Isik, S.; Ilgit, E.T.

    1998-01-01

    Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome. (orig.)

  6. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  7. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  8. Functional MR imaging on an open 1T MR imaging system: exploiting the advantages of an open MR imaging system for functional MR imaging

    NARCIS (Netherlands)

    van de Giessen, E.; Groot, P. F. C.; Booij, J.; van den Brink, W.; Veltman, D. J.; Nederveen, A. J.

    2011-01-01

    Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for

  9. Basic MR relaxation mechanisms and contrast agent design.

    Science.gov (United States)

    De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean

    2015-09-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. © 2015 Wiley Periodicals, Inc.

  10. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  11. MR-guided pain therapy: principles and clinical applications; MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Pereira, P.L. [Diagnostische Radiologie, Eberhard-Karls-Universitaet, Tuebingen (Germany)

    2007-09-15

    X-ray fluoroscopy and computed tomography are frequently used to perform percutaneous interventions in pain therapy. The development of MR-compatible therapy needles now allows these interventions to be performed under MR imaging guidance. MR-guided interventions may be performed using most clinical MR scanners; however, systems with an open configuration are advantageous. Multiplanar pre- and intra-procedural MR imaging provides the interventionalist with essential information, such as evaluation of anatomy and pathology, as well as the planning of the procedure and monitoring of fluid distribution without the use of contrast agents. With the use of non-ionizing radiation, interventional MR imaging is especially suited for the treatment of children and young adults as well as for serial injection therapy. For spinal MR interventions, passive needle visualization is an easily achievable and reliable method. The resulting needle artifact is influenced by several factors such as the alloy of the needle, the strength of the static magnetic field, the sequence type, the spatial orientation of the therapy needle as well as the echo time and may further be optimized during the intervention by alteration of the last three factors. Fast acquisition techniques and image processing allow for continuous, near real-time MR imaging (so-called MR fluoroscopy) and interactive needle navigations, comparable to X-ray fluoroscopy and CT fluoroscopy. The purpose of this review is to illustrate and discuss general concepts of interventional MR imaging. A spectrum of interventional MR imaging procedures in spinal pain therapy is described and illustrated, including procedures such as lumbar facet joint injections, sacroiliac joint injections, lumbar spinal nerve root infiltrations and drug delivery to the lumbar sympathetic chain. (orig.)

  12. MR imaging of colorectal carcinomas using an MR endoscopic coil

    International Nuclear Information System (INIS)

    Murano, Akihiko; Kido, Choichiro; Sasaki, Fumio; Nakamura, Tsuneya; Kobayashi, Semi; Katoh, Tomoyuki; Hirai, Takashi

    1994-01-01

    Diagnosis of the depth of wall invasion by rectal carcinoma using MR endoscopy was performed in ten resected specimens, including five rectal carcinomas, three colon carcinomas, two normal gastric wall. In addition, the gastric wall of a pig was examined. MR imaging was done with a 1.5-T Signa Advantage (GE Medical System) system, with the surface coil of the MR endoscope acting as the receiver coil. Five layers could be distinguished in the bowel wall: mucosa, submucosa and muscularis propria divided into circular muscle, longitudinal muscle and intervening connective tissue. Tumors had almost the same signal intensity as muscle. The MR images of colon carcinomas, rectal carcinomas, and extrinsically metastatic involvement of the sigmoid colon by rectal carcinoma all correlated well with the pathological findings. The normal structure of the gastric wall was similar to that of the colon. 3D-fast Spoiled Grass (SPGR) sequence has a fairly short scanning time. Thus, the possibility of precise clinical diagnosis by this method was suggested. (author)

  13. Current status of MR colonography.

    LENUS (Irish Health Repository)

    Thornton, Eavan

    2010-01-01

    The search for an acceptable colorectal cancer screening examination has led to the development of virtual colonoscopy, which includes both computed tomographic (CT) colonography and magnetic resonance (MR) colonography. As indicated by the much larger number of published studies on CT colonography than on MR colonography, multidetector CT appears to be more suitable for colorectal screening than does MR colonography, in part reflecting the ease and speed of performing CT, as well as the increased spatial resolution, decreased cost, and wider availability of CT colonography. The main advantage of MR colonography over CT colonography is that it does not use ionizing radiation, which has important implications for colorectal cancer screening. The use of dark-lumen MR colonography to screen patients for colorectal cancer as well as other abdominopelvic disease could make it more attractive than CT. With the integration of 3.0-T MR colonography, fecal tagging, and parallel imaging into research and clinical settings, new MR colonography protocols must be optimized. Future MR colonography research should address issues such as image characteristics, presence of artifacts, management of specific absorption rate, and hardware-related modifications.

  14. MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Hricak, H.

    1987-01-01

    MR imaging, CT, and US should be viewed as complementary studies for imaging the pelvis. MR imaging is relatively expensive, not widely available, and requires special facilities. However, it is noninvasive and offers a large field-of-view, direct imaging in all three orthogonal planes and excellent soft-tissue contrast. Surgical clips, which present a problem with other imaging modalities, do not create significant MR image artifacts. Image degradation due to bowel motion can be minimized by bowel preparation and/or the administration of glucagon. The value of MR imaging of the pelvis is in staging rather than diagnosis of pelvic neoplasms. The accuracy, sensitivity, and specificity of MR imaging in staging prostate or bladder tumors exceed those of US and CT. In prostate carcinoma, MR imaging can be used to evaluate periprostatic tumor extension, especially to the bladder base, rectum, or seminal vesicles. For early transcapsular extension, however, the accuracy of transrectal US reportedly surpasses that of MR imaging. In bladder carcinoma, the value of MR imaging is in direct tumor visualization, the ability to differentiate between tumor and normal bladder wall, and the evaluation of bladder tumors located at the dome of the bladder base, where imaging in the sagittal plane is essential. In the evaluation of benign entities of the female pelvis, US remains the preferred screening modality. The use of MR imaging is reserved for cases of infertility or for planning myomectomy when knowledge of the exact number, size, and location of tumors is essential. MR imaging is useful in evaluating patients with amenorrhea or any suspected congenital anomalies. The main application of MR imaging of the female pelvis is in the staging of neoplasms, including endometrial and cervical carcinomas

  15. Modern disposal techniques for sewage sludge and municipal waste; Moderne Entsorgungsverfahren fuer Klaerschlamm und Hausmuell

    Energy Technology Data Exchange (ETDEWEB)

    Garlipp, G. [Lurgi Energie und Umwelt GmbH, Frankfurt am Main (Germany); Maczek, K. [Lurgi Energie und Umwelt GmbH, Frankfurt am Main (Germany); Steinkamp, H. [Lurgi Energie und Umwelt GmbH, Frankfurt am Main (Germany)

    1996-05-01

    Since the passing of the technical code on municipal waste, the issue of the disposal of sewage sludge and municipal waste has become more and more important in Germany. Increasingly, the possibility is made use of to burn industrial and municipal sewage sludge and municipal waste. For such thermal disposal, a great number of techniques are nowadays available. (orig.) [Deutsch] Seit der Verabschiedung der TA Siedlungsabfall gewinnt die Problematik der Entsorgung von Klaerschlamm und Hausmuell in Deutschland zunehmend an Bedeutung. Von der Moeglichkeit, industrielle und kommunale Klaerschlaemme und Hausmuell zu verbrennen, wird in zunehmendem Masse Gebrauch gemacht. Zur thermischen Entsorgung von Klaerschlaemmen und Hausmuell stehen heute eine Vielzahl von Verfahren zur Verfuegung. (orig.)

  16. MR imaging of the brain: tumors

    International Nuclear Information System (INIS)

    Sartor, K.

    1999-01-01

    The radiologic modality that most likely provides the imaging information needed in a patient suspected of having a brain tumor is MR imaging. A brain tumor can be reliably ruled out if the MR examination is performed properly and experts interpret the results as negative. If there is a tumor, however, its exact location and topography must be determined. Important for therapy and prognosis are also tumor properties such as histologic type and grade, as well as effects on adjacent brain structures. Although potentially a noninvasive method of in vivo neuropathology, MR is still far from being sufficiently specific, as dissimilar lesions may look the same despite the use of refined imaging protocols. The evolution of MR imaging continues, however, making further methodologic improvement likely. Presently, advanced methods, such as diffusion- and perfusion-weighted MR imaging, functional MR imaging, neuronavigation based on MR imaging data, and the use of MR imaging during surgery (intraoperative MR imaging), influence the way patients are treated. Likewise, follow-up imaging (monitoring) of tumor patients by MR has become more effective, and experience has shown how to distinguish reactive changes from recurrent tumor. In the future, MR imaging may gain importance in the development of novel therapeutic concepts. (orig.)

  17. Safety issues and updates under MR environments

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jung; Kim, Kyung Ah, E-mail: bellenina@daum.net

    2017-04-15

    Highlights: • Unexpected biological effects can occur within stronger magnetic fields. • MR safety for MR conditional items is not guaranteed beyond the tested conditions. • Updated knowledge about MR-related safety is important for a safe MR environment. - Abstract: Magnetic resonance (MR) imaging is a useful imaging tool with superior soft tissue contrast for diagnostic evaluation. The MR environments poses unique risks to patients and employees differently from ionizing radiation exposure originated from computed tomography and plain x-ray films. The technology associated with MR system has evolved continuously since its introduction in the late 1970s. MR systems have advanced with static magnetic fields, faster and stronger gradient magnetic fields and more powerful radiofrequency transmission coils. Higher field strengths of MR offers greater signal to noise capability and better spatial resolution, resulting in better visualization of anatomic detail, with a reduction in scan time. With the rapid evolution of technology associated with MR, we encounter new MR-related circumstances and unexpected dangerous conditions. A comprehensive update of our knowledge about MR safety is necessary to prevent MR-related accidents and to ensure safety for patients and staff associated with MR. This review presents an overview about MR-related safety issues and updates.

  18. Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases

    NARCIS (Netherlands)

    Lam, Mie K; Huisman, Merel; Nijenhuis, Robbert J; van den Bosch, Maurice; Viergever, Max A; Moonen, Chrit Tw; Bartels, LW

    2015-01-01

    BACKGROUND: Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of

  19. Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators

    DEFF Research Database (Denmark)

    Keller, Sune H; Hansen, Casper; Hansen, Christian

    2015-01-01

    BACKGROUND: We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS......: Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigators sampled at six time points, which were used to correct the PET image for rigid head motion. Five subjects with motion greater than 4 mm were reconstructed into six frames (one for each navigator...

  20. The potentials of spiral CT for detection of focal liver lesions; Moeglichkeiten der Spiral-CT zur Diagnostik fokaler Leberlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Helmberger, H. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kersting-Sommerhoff, B. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Lenz, M. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kirsten, R. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Bautz, W. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany)

    1996-03-01

    Spiral CT currently is the modality of choice for all aspects of diagnostic evaluation of the liver. Optimal selection of treatment should be based inter alia on the findings obtained by spiral CT with arterial application of contrast medium, as for example S-CTA (primary liver tumors), or S-CTAP (secondary liver tumors). Ultrasonography is the major supplementing modality. In the near future, MR imaging applying liver-specific contrast-enhancing agents is expected to become an important competing technique, and further developments of interest in diagnostic imaging of the liver are in the offing: it is not yet known which technique will be the modality of choice at the onset of the 21st century. (orig.) [Deutsch] Die Spiral-CT ist zur Zeit das empfehlenswerte Verfahren fuer alle Fragen der Leberdiagnostik. Zur optimalen praetherapeutischen Beurteilung der Leber sollte die Spiral-CT mit arterieller Kontrastmittelapplikation als S-CTA (primaere Lebertumoren) bzw. S-CTAP (sekundaere Lebertumoren) durchgefuehrt werden. Der US kommt ein Stellenwert als ergaenzende Methode zu. In Zukunft wird die MRT mit leberspezifischen Kontrastmitteln ein konkurrierendes Verfahren zur Spiral-CT darstellen, wobei eine weitere interessante Entwicklung auf dem Gebiet der hepatischen Bildgebung zu erwarten ist: Das diagnostische Verfahren der Wahl fuer die Leber zu Beginn des 21. Jahrhunderts ist noch nicht definiert. (orig.)

  1. Accuracy and interobserver agreement between MR-non-expert radiologists and MR-experts in reading MRI for suspected appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Leeuwenburgh, Marjolein M.N., E-mail: m.m.leeuwenburgh@amc.uva.nl [Department of Surgery, Academic Medical Center, University of Amsterdam (Netherlands); Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Wiarda, Bart M. [Department of Radiology, Alkmaar Medical Center, Alkmaar (Netherlands); Jensch, Sebastiaan [Department of Radiology, Sint Lucas Andreas Hospital, Amsterdam (Netherlands); Wouter van Es, H. [Department of Radiology, Sint Antonius Hospital, Nieuwegein (Netherlands); Stockmann, Hein B.A.C. [Department of Surgery, Kennemer Gasthuis, Haarlem (Netherlands); Gratama, Jan Willem C. [Department of Radiology, Gelre Hospitals, Apeldoorn (Netherlands); Cobben, Lodewijk P.J. [Department of Radiology, Haaglanden Medical Center, Leidschendam (Netherlands); Bossuyt, Patrick M.M. [Department of Clinical Epidemiology, Academic Medical Center, University of Amsterdam (Netherlands); Boermeester, Marja A. [Department of Surgery, Academic Medical Center, University of Amsterdam (Netherlands); Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands)

    2014-01-15

    Objective: To compare accuracy and interobserver agreement between radiologists with limited experience in the evaluation of abdominal MRI (non-experts), and radiologists with longer MR reading experience (experts), in reading MRI in patients with suspected appendicitis. Methods: MR imaging was performed in 223 adult patients with suspected appendicitis and read independently by two members of a team of eight MR-inexperienced radiologists, who were trained with 100 MR examinations previous to this study (non-expert reading). Expert reading was performed by two radiologists with a larger abdominal MR experience (>500 examinations) in consensus. A final diagnosis was assigned after three months based on all available information, except MRI findings. We estimated MRI sensitivity and specificity for appendicitis and for all urgent diagnoses separately. Interobserver agreement was evaluated using kappa statistics. Results: Urgent diagnoses were assigned to 147 of 223 patients; 117 had appendicitis. Sensitivity for appendicitis was 0.89 by MR-non-expert radiologists and 0.97 in MR-expert reading (p = 0.01). Specificity was 0.83 for MR-non-experts versus 0.93 for MR-expert reading (p = 0.002). MR-experts and MR-non-experts agreed on appendicitis in 89% of cases (kappa 0.78). Accuracy in detecting urgent diagnoses was significantly lower in MR-non-experts compared to MR-expert reading: sensitivity 0.84 versus 0.95 (p < 0.001) and specificity 0.71 versus 0.82 (p = 0.03), respectively. Agreement on urgent diagnoses was 83% (kappa 0.63). Conclusion: MR-non-experts have sufficient sensitivity in reading MRI in patients with suspected appendicitis, with good agreement with MR-expert reading, but accuracy of MR-expert reading was higher.

  2. Accuracy and interobserver agreement between MR-non-expert radiologists and MR-experts in reading MRI for suspected appendicitis

    International Nuclear Information System (INIS)

    Leeuwenburgh, Marjolein M.N.; Wiarda, Bart M.; Jensch, Sebastiaan; Wouter van Es, H.; Stockmann, Hein B.A.C.; Gratama, Jan Willem C.; Cobben, Lodewijk P.J.; Bossuyt, Patrick M.M.; Boermeester, Marja A.; Stoker, Jaap

    2014-01-01

    Objective: To compare accuracy and interobserver agreement between radiologists with limited experience in the evaluation of abdominal MRI (non-experts), and radiologists with longer MR reading experience (experts), in reading MRI in patients with suspected appendicitis. Methods: MR imaging was performed in 223 adult patients with suspected appendicitis and read independently by two members of a team of eight MR-inexperienced radiologists, who were trained with 100 MR examinations previous to this study (non-expert reading). Expert reading was performed by two radiologists with a larger abdominal MR experience (>500 examinations) in consensus. A final diagnosis was assigned after three months based on all available information, except MRI findings. We estimated MRI sensitivity and specificity for appendicitis and for all urgent diagnoses separately. Interobserver agreement was evaluated using kappa statistics. Results: Urgent diagnoses were assigned to 147 of 223 patients; 117 had appendicitis. Sensitivity for appendicitis was 0.89 by MR-non-expert radiologists and 0.97 in MR-expert reading (p = 0.01). Specificity was 0.83 for MR-non-experts versus 0.93 for MR-expert reading (p = 0.002). MR-experts and MR-non-experts agreed on appendicitis in 89% of cases (kappa 0.78). Accuracy in detecting urgent diagnoses was significantly lower in MR-non-experts compared to MR-expert reading: sensitivity 0.84 versus 0.95 (p < 0.001) and specificity 0.71 versus 0.82 (p = 0.03), respectively. Agreement on urgent diagnoses was 83% (kappa 0.63). Conclusion: MR-non-experts have sufficient sensitivity in reading MRI in patients with suspected appendicitis, with good agreement with MR-expert reading, but accuracy of MR-expert reading was higher

  3. Development of a non-piston MR suspension rod for variable mass systems

    Science.gov (United States)

    Deng, Huaxia; Han, Guanghui; Zhang, Jin; Wang, Mingxian; Ma, Mengchao; Zhong, Xiang; Yu, Liandong

    2018-06-01

    The semi-active suspension systems for variable mass systems require long work stroke and variable damping, while the currently piston structure limits the work stroke for the magnetorheological (MR) dampers. The main work of this paper is to design a semi-active non-piston MR (NPMR) suspension rod for the reduction of the vibration of an automatic impeller washing machine, which is a typical variable mass system. The designed suspension rod locates in the suspension system that links the internal tub to the washing machine cabinet. The NPMR suspension rod includes a MR part and a air part. The MR part can provide low initial damping force and the unlimited work stroke compared with the piston MR damper. The hysteretic response tests and vibration performance evaluation with different loadings are conducted to verify the dynamic performance for the designed rod. The measured damping force of the MR part varies from 5 to 20 N. Studies of dehydration mode experiments of the washing machine indicate that its vibration acceleration with the NPMR suspension rods can reduce to half of the original passive ones in certain conditions.

  4. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Lower glucose-dependent insulinotropic polypeptide (GIP) response but similar glucagon-like peptide 1 (GLP-1), glycaemic, and insulinaemic response to ancient wheat compared to modern wheat depends on processing

    DEFF Research Database (Denmark)

    Bakhøj, S; Flint, A.; Holst, Jens Juul

    2003-01-01

    with honey-salt added, leavening crushed whole grain, and conventional leavening with yeast added. Bread made from modern wheat was prepared by conventional leavening with yeast added. SUBJECTS: A total of 11 healthy young men. RESULTS: The postprandial GIP response was significantly (P... by the Einkorn breads processed with honey-salt leavening and by using crushed whole grain bread compared to the yeast leavened bread made from modern wheat or from Einkorn. No significant differences were found in the responses of GLP-1, insulin or glucose. CONCLUSION: Einkorn honey-salt leavened and Einkorn...... whole grain bread elicit a reduced gastrointestinal response of GIP compared to conventional yeast bread. No differences were found in the glycaemic, insulinaemic and GLP-1 responses. Processing of starchy foods such as wheat may be a powerful tool to modify the postprandial GIP response....

  6. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  7. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  8. Visit of Mr. Susumu Yoda, Japanese Atomic Energy Commission, Mr. Nobuo Natsume, Vice-President, Central Research Institute of Electric Power Industry, Japan (CRIEPI), Mr. Nobuya Yoshiki, CRIEPI, Mrs. Seiko Ichikawa, Interpreter, with Mr. Taylor of CERN, visiting SM18

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    Visit of Mr. Susumu Yoda, Japanese Atomic Energy Commission, Mr. Nobuo Natsume, Vice-President, Central Research Institute of Electric Power Industry, Japan (CRIEPI), Mr. Nobuya Yoshiki, CRIEPI, Mrs. Seiko Ichikawa, Interpreter, with Mr. Taylor of CERN, visiting SM18

  9. MR-Guided vacuum biopsy of 206 contrast-enhancing breast lesions; MRT-gefuehrte Vakuumbiopsie bei 206 Kontrastmittel anreichernden Laesionen der Mamma

    Energy Technology Data Exchange (ETDEWEB)

    Perlet, C.; Schneider, P.; Sittek, H.; Reiser, M.F. [Klinikum der Universitaet Grosshadern, Muenchen (Germany). Inst. fuer Klinische Radiologie; Amaya, B.; Grosse, A.; Heywang-Koebrunner, S.H. [Martin-Luther-Universitaet, Halle (Germany). Klinik fuer Diagnostische Radiologie

    2002-01-01

    Purpose: To determine the accuracy and clinical use of MR-guided vacuum biopsy (VB) of enhancing breast lesions. Material and Methods: 254 lesions were referred to MR-guided vacuum-assisted breast biopsy. In 43 (16%) patients the indication was dropped because the lesions could not be identified at the time VB was scheduled. This was due to hormonal influences (n=37), to too strong compression (n=3) or to misinterpretation of the initial diagnostic MRI. In 5 cases (2%) VB was not performed due to obesity (n=2); problems of access (n=2) or a defect of the MR-unit (n=1). VB was performed on altogether 206 lesions. In 4 cases (2%) VB was unsuccessful. This was immediately realized on the post-interventional images. Thus a false negative diagnosis was avoided. Verification included excision of the cavity in cases with proven malignancy or atypical ductal hyperplasia (ADH) and (for benign lesions) retrospective correlation of VB-histology with pre- and postinterventional MRI and subsequent follow-up. Results: 51/202 successful biopsies proved malignancy. In 7 cases ADH and in 144 cases a benign lesion was diagnosed. One DCIS was underestimated as ADH. All other benign or malignant diagnoses proved to be correct. Conclusion: MR-guided VB allows reliable histological work-up of contrast-enhancing small lesions which are not visible by any other modality. (orig.) [German] Zielsetzung: Evaluation der Wertigkeit und klinischen Anwendbarkeit der MRT-gefuehrten Vakuumbiopsie (VB) bei anreichernden Mammalaesionen. Material und Methoden: Insgesamt wurden 254 Laesionen der MRT-gefuehrten VB zugewiesen. Hiervon entfiel bei 43 Patientinnen (16%) die Biopsieindikation beim Planungs-MRT, da die urspruengliche Anreicherung hormonell (n=37), durch zu starke Kompression (n=3) oder durch eine Fehlinterpretation des vorausgegangenen diagnostischen MRT (n=3) nicht mehr abgrenzbar war. Bei 5 weiteren Laesionen (2%) war die Biopsie nicht moeglich (Adipositas n=2; Zugangsprobleme n=2; MRT

  10. MR myelography of sacral meningeal cysts

    International Nuclear Information System (INIS)

    Tsuchiya, K.; Katase, S.; Hachiya, J.

    1999-01-01

    Purpose: To describe the findings of sacral meningeal cysts (SMCs) on MR myelography and assess its value for the diagnosis of SMCs. Material and Methods: We evaluated the MR images and MR myelograms obtained from 10 patients with SMC. MR myelograms were obtained using a 2D or 3D single-shot fast spin-echo sequence. In 5 patients, X-ray myelograms and postmyelographic CT images were compared with the MR myelograms. Results: A total of 33 SMCs were diagnosed within the spinal canal and/or sacral foramen. MR myelograms clearly revealed each cyst as a well-defined mass showing hyperintensity (10 cysts) or isointensity (23 cysts) compared to cerebrospinal fluid. MR myelograms demonstrated SMCs better than X-ray myelograms and postmyelographic CT images in 3 of the 5 patients. Conclusion: MR myelography can be an adjunct to conventional imaging techniques when surgical treatment is indicated, because it can precisely delineate the extent of SMCs. (orig.)

  11. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Fritts, H.M.; Craig, E.; Kyle, R.; Strefling, M.; Miller, D.; Heithoff, K.; Schellhas, K.

    1988-01-01

    Magnetic resonance (MR) imaging (1.5-T unit) was performed in over 600 shoulders to evaluate shoulder pain. Ultrasound (US) and arthrography were performed in over 100 patients. Surgery was performed in over 75 patients. MR imaging offers information not well evaluated with other modalities, including bony impingement, tendinitis, bursitis, and osseous abnormalities, such as primary arthritis, avascular necrosis, occult fractures, and tumors. US and MR findings correlate well with surgical findings for medium to large rotator cuff tears. MR imaging with T2 weighting is superior for differentiating small tears from associated tendinitis. An algorithm for cost-effective shoulder imaging integrating US, MR imaging, arthrography, and computed tomographic arthrography are presented

  12. MR appearance of central neurocytoma

    International Nuclear Information System (INIS)

    Chang, K.H.; Han, M.H.; Kim, D.G.; Chi, J.G.; Suh, D.C.; Kim, S.J.; Cha, S.H.; Han, M.C.

    1993-01-01

    To provide a detailed description of the MR appearances of central neurocytoma, MR images of 13 patients with central neurocytoma were retrospectively reviewed and compared with CT examinations. The histology was confirmed by ultrastructural and immunohistochemical studies. In 12 patients the tumors were histologically benign and located in the anterior part of the lateral ventricle, 6 of which extended to the 3rd ventricle. There was one case of a histologically malignant variant involving the thalamus and lateral ventricle. The tumors were primarily solid, but contained cysts (85%, 11/13), calcifications (69%, 9/13), and signal void from tumor vessels (62%, 8/13), frequently producing heterogeneous signal intensity on both T1- and T2-weighted images. Most of the solid portion appeared isointense or slightly hyperintense relative to the cerebral cortex on all MR pulse sequences. Calcifications were iso- or hypointense on MR, making them difficult to characterize with MR alone. Intratumoral hemorrhage was seen in 2 patients on MR but not on CT. Contrast enhancement was variable in degree and pattern. Coronal and sagittal MR images were valuable in evaluating the tumor extent and origin site, and in planning the surgical approach. It is concluded that MR imaging appears to be more useful than CT in the overall evaluation of central neurocytoma, even though calcification is better characterized with CT. (orig.)

  13. First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system

    International Nuclear Information System (INIS)

    Fallone, B. G.; Murray, B.; Rathee, S.; Stanescu, T.; Steciw, S.; Vidakovic, S.; Blosser, E.; Tymofichuk, D.

    2009-01-01

    The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the linac target is 80 cm. The authors' design has resolved the mutual interferences between the two devices such that the MR magnetic field does not interfere with the trajectory of the electron in the linac waveguide, and the radiofrequency (RF) signals from each system do not interfere with the operation of the other system. Magnetic and RF shielding calculations were performed and confirmed with appropriate measurements. The prototype is currently on a fixed gantry; however, in the very near future, the linac and MR magnet will rotate in unison such that the linac is always aimed through the opening in the biplanar magnet. MR imaging was found to be fully operational during linac irradiation and proven by imaging a phantom with conventional gradient echo sequences. Except for small changes in SNR, MR images produced during irradiation were visually and quantitatively very similar to those taken with the linac turned off. This prototype system provides proof of concept that the design has decreased the mutual interferences sufficiently to allow the development of real-time MR-guided radiotherapy. Low field-strength systems (0.2-0.5 T) have been used clinically as diagnostic tools. The task of the linac-MR system is, however, to provide MR guidance to the radiotherapy beam. Therefore, the 0.2 T field strength would provide adequate image quality for this purpose and, with the addition of fast imaging techniques, has the potential to provide 4D soft-tissue visualization not presently available in image-guided radiotherapy systems. The authors' initial design incorporates a

  14. Osteochondrosis dissecans of the knee: Evaluation of the evolution of MR morphology during treatment

    International Nuclear Information System (INIS)

    Palczewski, P.; Golebiowski, M.; Strzelczyk, P.

    2008-01-01

    To assess the evolution of MR morphology of OCD lesions in response to treatment and feasibility of MRI as a control study in patients with treated OCD. 11 patients (6 women and 5 men, aged 11-24 years, average age 17 years) with lesions affecting 12 knee joints were followed for approximately 24.2 months with repeated clinical examination and MR imaging. All MR studies were performed on a 1.5 Tesla unit. MR arthrography was performed in 3 patients. The evolution of MR morphology of the lesions was assessed with a 5-point scale and correlated with the results of clinical assessment with a modified Lysholm scale. In 10 patients, a good clinical result was achieved. In 7 knee joints of patients from this group, the features of the healing of the OCD lesion were observed in MRI and in 4 knees the morphology of the OCD lesion was stable. In 5 MR examinations, a transient deterioration was observed, which in 4 cases preceded healing and in 1 case stabilization in MR morphology. Transient deterioration may be observed in MR studies prior to the healing of OCD lesions irrespective of the improvement in clinical examination. The follow up of patients with OCD should be based mainly on clinical examination, with MR studies reserved for late control or patients with clinical signs of deterioration. (author)

  15. A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner

    International Nuclear Information System (INIS)

    Slates, R.B.; Farahani, K.; Marsden, P.K.; Taylor, J.; Summers, P.E.; Williams, S.; Beech, J.

    1999-01-01

    We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T 2 -weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner. (author)

  16. 'Modernization property' of our country is visualized / TAISEI; Wagakuni no 'kindaika isan' wo eizoka / taiseisensetsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-10

    TAISEI was about rapidly promoted from Days of the Tokugawa shogunate over Meiji and Taisho this, and the documentary film which focused on building and 'the modernization property' which are related to industry and traffic and civil engineering which made the base of the our country development was planned and was produced. The title of the movie is 'travel to the Japan modernization property'. The movie which really introduced such modern age property is rare, and it s as an image material precious. It tries to pick up main thing, The oldest lighthouse 'Mikomotojima Island lighthouse (Shizuoka Prefect.1870)' and covers Shiga Prefecture and Kyoto prefecture,'The Lake Biwa hydrophobic', in our country, the first gravitational concrete dam 'Nunobiki Gohnmatsu dam, Kobe City, 1900'Length furnace for the cement baking which remains in Yamaguchi Prefect. 'The ONODA CEMENT (Pacific Ocean cement) sake bottle furnace'. In becoming modernization property which widely remains in our country and so on the guide person, Mr. Shinbo Minami of the illustrator has introduced it. The narration is the Mr. platform step of the actress. Still, screening party of this movie is done in the following schedule (admission free). The detailed query is Japanese movie new Co. (141-0021 2-10-17 Kami-Osaki, Shinagawa ku, Tokyo), TEL 03-3442-7251 FAX 03-3442-7360. (translated by NEDO)

  17. Simulation of thermal radiation, illustrated by the Bridgman casting process for directional solidification of turbine blades; Simulation von Waermestrahlung am Beispiel des Bridgman-Verfahrens zur gerichteten Erstarrung von Turbinenschaufeln

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, N

    1996-12-31

    Directionally solidified turbine blades for high-temperature applications today are commonly produced by the Bridgman casting process. The production of a newly constructed turbine blade requires a number of costly and time-consuming casting experiments. The author develops a numerical simulation model based on the finite element method and net radiation method for low-cost and short-term simulation and optimisation of the casting experiments. Several different numerical methods for calculating thermal radiation are compared (radiosity, ray tracing and the finite difference method), and the simulation results are presented for several exemplry turbine blades. Further, an optimisation strategy for improving the quality of the turbine blade casting process is presented. (orig.). 65 figs., 8 tabs. [Deutsch] Gerichtet erstarrte Turbinenschaufeln mit hoher Einsatztemperatur werden nach dem heutigen Stand der Technik nach dem Bridgman-Verfahren gegossen. Die Herstellung einer neu konstruierten Turbinenschaufel verlangt eine Reihe von kosten- und zeitaufwendigen Giessexperimenten. In der vorliegenden Arbeit wird ein numerisches Simulationsmodell auf Basis der Finiten Elemente Methode und Net Radiation Methode entwickelt, mit dem sich kostenguenstig und in kurzen Zeitraeumen die Giessversuche simulieren und optimieren lassen. Die Arbeit vergleicht verschiedene numerische Loesungsverfahren fuer die Waermestrahlung (Radiosity, Ray Tracing und Finite Differenzen Verfahren) und stellt am Beispiel einiger Turbinenschaufeln die Simulationsergebnisse dar. Weiterhin wird eine Optimierungsstrategie fuer Verbesserung der Gussqualitaet von Turbinenschaufeln vorgestellt. (orig.)

  18. Diagnostic Efficiency of MR Imaging of the Knee. Relationship to time Interval between MR and Arthroscopy

    International Nuclear Information System (INIS)

    Barrera, M. C.; Recondo, J. A.; Aperribay, M.; Gervas, C.; Fernandez, E.; Alustiza, J. M.

    2003-01-01

    To evaluate the efficiency of magnetic resonance (MR) in the diagnosis of knee lesions and how the results are influenced by the time interval between MR and arthroscopy. 248 knees studied by MR were retrospectively analyzed, as well as those which also underwent arthroscopy. Arthroscopy was considered to be the gold standard, MR diagnostic capacity was evaluated for both meniscal and cruciate ligament lesions. Sensitivity, specificity and Kappa index were calculated for the set of all knees included in the study (248), for those in which the time between MR and arthroscopy was less than or equal to three months (134) and for those in which the time between both procedures was less than or equal to one month. Sensitivity, specificity and Kappa index of the MR had global values of 96.5%, 70% and 71%, respectively. When the interval between MR and arthroscopy was less than or equal to three months, sensitivity, specificity and Kappa index were 95.5%, 75% and 72%, respectively. When it was less than or equal to one month, sensitivity was 100%, specificity was 87.5% and Kappa index was 91%. MR is an excellent tool for the diagnosis of knee lesions. Higher MR values of sensitivity, specificity and Kappa index are obtained when the time interval between both procedures is kept to a minimum. (Author) 11 refs

  19. Interobserver agreement of radiologists assessing the response of rectal cancers to preoperative chemoradiation using the MRI tumour regression grading (mrTRG)

    International Nuclear Information System (INIS)

    Siddiqui, M.R.S.; Gormly, K.L.; Bhoday, J.; Balyansikova, S.; Battersby, N.J.; Chand, M.; Rao, S.; Tekkis, P.; Abulafi, A.M.; Brown, G.

    2016-01-01

    Aim: To investigate whether the magnetic resonance imaging (MRI) tumour regression grading (mrTRG) scale can be taught effectively resulting in a clinically reasonable interobserver agreement (>0.4; moderate to near perfect agreement). Materials and methods: This study examines the interobserver agreement of mrTRG, between 35 radiologists and a central reviewer. Two workshops were organised for radiologists to assess regression of rectal cancers on MRI staging scans. A range of mrTRGs on 12 patient scans were used for assessment. Results: Kappa agreement ranged from 0.14–0.82 with a median value of 0.57 (95% CI: 0.37–0.77) indicating good overall agreement. Eight (26%) radiologists had very good/near perfect agreement (κ>0.8). Six (19%) radiologists had good agreement (0.8≥κ>0.6) and a further 12 (39%) had moderate agreement (0.6≥κ>0.4). Five (16%) radiologists had a fair agreement (0.4≥κ>0.2) and two had poor agreement (0.2>κ). There was a tendency towards good agreement (skewness: 0.92). In 65.9% and 90% of cases the radiologists were able to correctly highlight good and poor responders, respectively. Conclusions: The assessment of the response of rectal cancers to chemoradiation therapy may be performed effectively using mrTRG. Radiologists can be taught the mrTRG scale. Even with minimal training, good agreement with the central reviewer along with effective differentiation between good and intermediate/poor responders can be achieved. Focus should be on facilitating the identification of good responders. It is predicted that with more intensive interactive case-based learning a κ>0.8 is likely to be achieved. Testing and retesting is recommended. - Highlights: • Inter-observer agreement of radiologists was assessed using MRI rectal tumour regression scale. • Kappa agreement had a median value of 0.57 (95% CI: 0.37–0.77) indicating an overall good agreement. • In 65.9% and 90% of cases the radiologists were able to correctly highlight

  20. Preview control of vehicle suspension system featuring MR shock absorber

    Energy Technology Data Exchange (ETDEWEB)

    Seong, M S; Choi, S B [Smart Structures and Systems Laboratory, Department of Mechanical Engineering, Inha University, Incheon 402-751 (Korea, Republic of); Cho, M W [Precision Manufacturing and Inspection Laboratory, Department of Mechanical Engineering, Inha University, Incheon 402-751 (Korea, Republic of); Lee, H G [Department of Automotive Engineering, Daeduk College, Daejeon, 305-715 (Korea, Republic of)], E-mail: seungbok@inha.ac.kr

    2009-02-01

    This paper presents control performance evaluation of optimal preview control algorithm for vehicle suspension featuring MR shock absorber. The optimal preview control algorithm has several advantages such as high control performance over that which is best for a non-preview system. In order to achieve this goal, a commercial MR shock absorber, Delphi MganerideTM, which is applicable to high class passenger vehicle, is adopted and its field-dependent damping force and dynamic responses are experimentally evaluated. Then the governing equation of motion for the full-vehicle model is established and integrated with the MR shock absorber. Subsequently, optimal controller with preview control algorithm is formulated and implemented for vibration suppression of the car body. Control performance of the preview controller is evaluated for the full-vehicle model under random road condition. In addition, the control performances depending on preview distances are evaluated.

  1. Preview control of vehicle suspension system featuring MR shock absorber

    International Nuclear Information System (INIS)

    Seong, M S; Choi, S B; Cho, M W; Lee, H G

    2009-01-01

    This paper presents control performance evaluation of optimal preview control algorithm for vehicle suspension featuring MR shock absorber. The optimal preview control algorithm has several advantages such as high control performance over that which is best for a non-preview system. In order to achieve this goal, a commercial MR shock absorber, Delphi MganerideTM, which is applicable to high class passenger vehicle, is adopted and its field-dependent damping force and dynamic responses are experimentally evaluated. Then the governing equation of motion for the full-vehicle model is established and integrated with the MR shock absorber. Subsequently, optimal controller with preview control algorithm is formulated and implemented for vibration suppression of the car body. Control performance of the preview controller is evaluated for the full-vehicle model under random road condition. In addition, the control performances depending on preview distances are evaluated.

  2. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  3. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  4. Development of production-integrated methods of reducing environmental pollution by reducing energy and materials consumption in a textile finishing plant. Final report; Entwicklung produktionsintegrierter Verfahren zur Reduzierung von Umweltbelastungen durch Minimierung der Energie- und Stoffstrommassenstroeme am Beispiel eines Textilveredlungsbetriebes. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-11-01

    The textile finishing industry is an industry with high consumption of energy, materials (dyes, finishing agents, chemicals), and water, and with a complex technology. The industry is forced to reduce organic water pollutants as well as the consumption of energy and water. This research project is to provide the fundamentals for further research. [German] Die mittelstaendisch strukturierte Textilveredlungsindustrie ist hinsichtlich ihres Energie- und Hilfsstoffbedarfs (Farbstoffe, Textilhilfsmittel, Chemikalien), des Bedarfs an Wasser als Loesemittel bzw. Medium fuer den Stofftransfer und der vorgegebenen Prozesstechnik zunehmend gezwungen, produktionsintegrierte Konzepte zur Reduzierung gewaesserrelevanter organischer Stoffe als auch des spezifischen Energie- und Wasserbedarfs zu entwickeln. Das geplante Forschungsvorhaben soll Grundlagen fuer produktionsintegrierte Massnahmen bzw. Verfahren schaffen, die zukunftsweisend - mit ausgepraegt oekonomischen Wirkungen - weitere Fortschritte bei Entlastung der Umweltkompartimente Wasser und Boden generieren. In diesem Sinne kommen anstelle der bislang ueberwiegend angewandten additiven Technologien nur Verfahren in Frage, die sich auf spezifisch belastete Abwasserteilstroeme konzentrieren, deren Behandlungsfaehigkeit vor dem Hintergrund der erwarteten Inhaltsstoffe untersucht werden soll. (orig.)

  5. 3D-MR Spectroscopic Imaging at 3Tesla for Early Response Assessment of Glioblastoma Patients during External Beam Radiation Therapy

    Science.gov (United States)

    Muruganandham, Manickam; Clerkin, Patrick P; Smith, Brian J; Anderson, Carryn M; Morris, Ann; Capizzano, Aristides A; Magnotta, Vincent; McGuire, Sarah M; Smith, Mark C; Bayouth, John E; Buatti, John M

    2014-01-01

    Purpose To evaluate the utility of 3D-MR proton spectroscopic imaging for treatment planning and its implications for early response assessment in glioblastoma multiforme. Methods and Materials Eighteen patients with newly diagnosed, histologically confirmed glioblastoma had 3D-MR proton spectroscopic imaging (MRSI) along with T2 and T1 gadolinium enhanced MR images at simulation and at boost treatment planning after 17-20 fractions of radiotherapy. All patients received standard radiotherapy with temozolomide and follow-up with every two month MR scans. Progression free survival was defined using MacDonald criteria. MRSI images obtained at initial simulation were analyzed for choline / N-acetylaspartate ratios (Cho/NAA) on a voxel by voxel basis with abnormal activity defined as Cho/NAA ≥ 2. These images were compared on anatomically matched MRSI data collected after 3 weeks of radiotherapy. Changes in Cho/NAA between pre-therapy and 3rd week RT scans were tested using Wilcoxon matched-pairs signed rank tests and correlated with progression free survival, radiation dose and location of recurrence using Cox proportional hazards regression. Results After 8.6 months (median follow-up), 50% of patients had progressed based on imaging. Patients with a decreased or stable mean or median Cho/NAA values had less risk of progression (p< 0.01). Patients with an increase in mean or median Cho/NAA values at the 3rd week RT scan had a significantly greater chance of early progression (p <0.01). An increased Cho/NAA at the 3rd week MRSI scan carried a hazard ratio of 2.72 (95% confidence interval 1.10-6.71, p= 0.03). Most patients received the prescription dose of RT to the Cho/NAA ≥ 2 volume, which was where recurrence most often occurred. Conclusion Change in mean and median Cho/NAA detected at 3 weeks was a significant predictor of early progression. The potential impact for risk-adaptive therapy based on early spectroscopic findings is suggested. PMID:24986746

  6. MR cholangiography: usefulness in obstructive jaundice

    International Nuclear Information System (INIS)

    Bae, Sang Hoon; Lee, In Jae; Nam, Kung Sook; Hong, Myung Sun; Lee, Kyung Hwan; Yun, Ku Sub

    1994-01-01

    Three-dimensional(3D) magnetic resonance(MR) projection imaging was evaluated as a noninvasive alternative to direct cholangiography for the assessment of its reliability in patients with obstructive jaundice. A heavily T2-weighted gradient-echo sequence(PSIF) was used for 3D MR projection imaging of the biliary system in five healthy volunteers and 25 patients with obstructive jaundice. The 3D images of the bile ducts were formed by stacking consecutive coronal MR images obtained with a fast imaging method to a maximum-intensity projection algorithm. In the volunteers, MR cholangiography could demonstrate the anatomy of the biliary tract in only two subjects. The extrahepatic and intrahepatic bile ducts were well visualized in 23 patients with obstructive jaundice. The leve of obstruction and the grade of dilatation were depicted with MR cholangiography in all cases. And the cause of obstruction could be determined with MR cholangiography in 18 cases, MR cholangiography wa successful in two patients in whom ERCP failed. The gallbladder or dilated pancreatic duct not demonstrated by means of direct cholangiography was demonstrated with MR cholangiography in six cases. MR cholangiography may be a useful adjunctive tool for the noninvasive evaluation of patients with obstructive Jaundice

  7. T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); UMR INSERM 965, Hôpital Lariboisière, 2 Rue Amboise Paré, 75010 Paris (France); Gavini, Jean-Philippe, E-mail: jpgavini@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Placé, Vinciane, E-mail: vinciane.place@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sebbag, Delphine, E-mail: delphinesebbag@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Vignaud, Alexandre, E-mail: alexandre.vignaud@cea.fr [LRMN, Neurospin, CEA-SACLAY, Bâtiment 145, 91 191 Gif-sur-Yvette Cedex (France); and others

    2013-11-01

    Objective: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. Materials and methods: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. Results: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median = 22.82) than TSE MR imaging (median = 14.15) (P < .001). No differences were found for SNR of hepatic parenchyma (P = .097), main focal hepatic lesions (P = .35), and splenic parenchyma (P = .25). SPACE sequence showed less artifacts than TSE sequence (vascular, P < .001; respiratory motion, P < .001; cardiac, P < .001) but needed a longer acquisition time (228.4 vs. 162.1 s; P < .001). Conclusion: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.

  8. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  9. MR-guided lumbar sympathicolysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H. [Department of Diagnostic Radiology, University of Tuebingen (Germany); Schneider, Wilke [Department of Vascular Surgery, University of Tuebingen (Germany)

    2002-06-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  10. MR-guided lumbar sympathicolysis

    International Nuclear Information System (INIS)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H.; Schneider, Wilke

    2002-01-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  11. Interventional oncology in urology; Interventionelle Onkologie in der Urologie

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J. [Klinikum Passau, Institut fuer Diagnostische und Interventionelle Radiologie/Neuroradiologie, Passau (Germany)

    2007-12-15

    angewendete Verfahren. Moderne Sondentypen ermoeglichen Laesionsgroessen zwischen 2 und 5 cm. Die RFA wird ueberwiegend perkutan unter Ultraschall- oder CT-Kontrolle vorgenommen, gilt als sicher und komplikationsarm. Wenngleich randomisierte Vergleichsstudien zu operativen Verfahren noch immer fehlen, sind die bisherigen Erfahrungen gut und lassen die RFA gegenueber den anderen thermischen Verfahren vorteilhaft erscheinen. Fuer die RFA sowie die seltener angewendete Kryotherapie betragen die klinischen Erfolgsraten ueber 90%; Tumorrezidive sind sehr selten. (orig.)

  12. Skeletal MR imaging: Correlation with skeletal scintigraphy

    International Nuclear Information System (INIS)

    Colletti, P.M.; Raval, J.K.; Ford, P.V.; Benson, R.C.; Kerr, R.M.; Boswell, W.D.; Siegel, M.E.; Ralls, P.W.

    1987-01-01

    Skeletal MR images bone marrow while skeletal scintigraphy uses bone metabolism to demonstrate abnormalities. The purpose of this paper is to correlate these MR and scintigraphic findings. T1 and T2 MR images at 0.5 T were correlated with planar bone scintigraphy (RN) using Tc-99m MDP in 56 patients. Of 23 cases with suspected spinal metastases, 19 were positive by MR imaging, 16 by RN. Individual lesions were shown better by MR imaging in five and by RN in two. These two cases had scoliosis, a potential difficulty with MR imaging. In 14 cases of suspected avascular necrosis (AVN), MR imaging was positive in 13 while RN was positive in ten. One negative case by RN had bilateral AVN by MR imaging. Four skull lesions shown easily by RN were seen only in retrospect on MR images. MR imaging is advantageous in evaluating bones with predominant marrow such as vertebrae or the femoral head, while RN is superior in areas primarily composed of cortical bone such as the skull

  13. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  14. MrSkn7 controls sporulation, cell wall integrity, autolysis, and virulence in Metarhizium robertsii.

    Science.gov (United States)

    Shang, Yanfang; Chen, Peilin; Chen, Yixiong; Lu, Yuzhen; Wang, Chengshu

    2015-04-01

    Two-component signaling pathways generally include sensor histidine kinases and response regulators. We identified an ortholog of the response regulator protein Skn7 in the insect-pathogenic fungus Metarhizium robertsii, which we named MrSkn7. Gene deletion assays and functional characterizations indicated that MrSkn7 functions as a transcription factor. The MrSkn7 null mutant of M. robertsii lost the ability to sporulate and had defects in cell wall biosynthesis but was not sensitive to oxidative and osmotic stresses compared to the wild type. However, the mutant was able to produce spores under salt stress. Insect bioassays using these spores showed that the virulence of the mutant was significantly impaired compared to that of the wild type due to the failures to form the infection structure appressorium and evade host immunity. In particular, deletion of MrSkn7 triggered cell autolysis with typical features such as cell vacuolization, downregulation of repressor genes, and upregulation of autolysis-related genes such as extracellular chitinases and proteases. Promoter binding assays confirmed that MrSkn7 could directly or indirectly control different putative target genes. Taken together, the results of this study help us understand the functional divergence of Skn7 orthologs as well as the mechanisms underlying the development and control of virulence in insect-pathogenic fungi. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  15. MR of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Spickler, E.; Lufkin, R.; Frazee, J.; Lylyk, P.; Vinuela, F.; Bentson, J.; Dion, J.

    1987-01-01

    Subarachnoid hemorrhage was produced in four Macaca nemestrina monkeys using the technique of Frazee. CT and MR imaging was performed immediately after the procedure and at frequent intervals up to 2 weeks after hemorrhage. The imaging studies were compared with clinical evaluations and pathologic specimens of all animals. Additional human clinical CT/MR studies of subarachnoid hemorrhage were also studied. Acute hemorrhage was recognized on MR images as an increase in signal in the region of clot compared with surrounding cerebrospinal fluid. This most likely reflects T1 shortening due to proton binding rather than a pure paramagnetic effect. While CT is sensitive to the hemoglobin protein in acute hemorrhage, the superior resolution of MR of the basal cisterns results in equal or better definition of acute subarachnoid hemorrhage on MR studies in many cases

  16. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Magnetic resonance (MR) defecography is a special ... with you. top of page What are the benefits vs. risks? Benefits MR defecography helps assess pelvic ...

  17. MR arthrography of the shoulder: possible indications for clinical use; Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Grebe, P. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Kersjes, W. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik fuer Unfallchirurgie; Kirschner, P. [Elisabeth-Hospital, Mainz (Germany). Abt. fuer Unfall- und Wiederherstellungschirurgie St. Vincenz; Schild, H.H. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie

    1994-02-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [Deutsch] In einer prospektiven Studie sollten Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes herausgearbeitet werden. 37 Patienten wurden sowohl nativ als auch nach intraartikulaerer Gabe einer 2mmolaren Gd-DTPA-Loesung untersucht. Voraussetzungen fuer die KM-Gabe waren ein fehlender Gelenkerguss und/oder ein unklarer Befund des Labrum-Kapsel-Komplexes oder der Rotatorenmanschette in der Nativuntersuchung. Durch die MR-Arthrographie wurde bei 11/22 Patienten eine verbesserte Darstellung der Labrumpathologie erzielt; in 20/22 Faellen ergabe sich eine zuverlaessige Beurteilung der Gelenkkapsel. Bei 9/15 Patienten mit Erkrankungen der Rotatorenmanschette konnten Tendinitiden von partiellen und kleinen kompletten Rotatorenmanschettenrupturen sicher differenziert werden. Die MR-Arthrographie des Schultergelenkes fuehrt bei nicht eindeutigen Befunden in der Nativuntersuchung zu einer verbesserten Treffsicherheit der MR-Diagnostik. (orig.)

  18. Modern biogeochemistry environmental risk assessment

    CERN Document Server

    Bashkin, Vladimir N

    2006-01-01

    Most books deal mainly with various technical aspects of ERA description and calculationsAims at generalizing the modern ideas of both biogeochemical and environmental risk assessment during recent yearsAims at supplementing the existing books by providing a modern understanding of mechanisms that are responsible for the ecological risk for human beings and ecosystem

  19. US and MR imaging of pelvic masses

    International Nuclear Information System (INIS)

    Angtuaco, T.L.; Boyd, C.M.; Mattison, D.R.; Williamson, M.R.; Sanders, M.M.; Bard, D.S.

    1987-01-01

    US and MR imaging were compared in benign and malignant pelvic masses to determine where MR imaging may replace US. With regard to benign masses, MR imaging showed a significant advantage only in the imaging of teratomas. In malignancy, US was better than MR imaging in delineating internal architecture. MR imaging was superior in suggesting the origin and extent of masses, especially in large neoplasms. US remains a reliable tool in the initial evaluation of pelvic masses. When US studies are suboptimal, MR imaging should be performed as complementary study. MR imaging may replace US in the initial examination of large masses where US cannot depict the origin and extent

  20. Mr. Ansar Shamsi, Member Finance, Mr. Malik Adalat Khan, Director Finance, Pakistan Atomic Energy Commission

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    Photo 01: Mr Ansar Shamsi, Member Finance, Pakistan Atomic Energy Commission (centre), visiting the ATLAS Tile Calorimeter in building 191 with, from left to right, Mr Syed Shaukat Hussain, Pakistan Mission in Geneva and Dr Peter Jenni, ATLAS Spokesperson. Photo 02: Mr Ansar Shamsi, Member Finance, Pakistan Atomic Energy Commission (2nd form left), visiting the ATLAS Tile Calorimeter in building 191 with, from left to right, Mr Syed Shaukat Hussain, Pakistan Mission in Geneva; Dr Peter Jenni, ATLAS Spokesperson; Dr David Jacobs and Dr Philip Bryant, Joint Pakistan-CERN Committee.

  1. Part project 1. Methods and concepts of biological waste composting. Comparison - evaluation - recommendations; Teilbericht 1. Verfahren und Konzepte der Bioabfallkompostierung. Vergleich - Bewertung - Empfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Gronauer, A; Helm, M; Schoen, H [Bayerische Landesanstalt fuer Landtechnik der Technischen Univ. Muenchen-Weihenstephan (Germany)

    1998-12-31

    Topics of this article are: composting of biological wastes; techniques, operation modes, regional concepts, engineering, hygienical, ecological, economical aspects. (SR) gardening plots. The project comprised three parts: Composting techniques, applications of compost in agriculture and gardening, and applications in landscaping. This volume comprises the summaries of the three part-projects. (orig./SR) [Deutsch] Das uebergeordnete Ziel des Weihenstephaner Verbundvorhabens bestand darin, fachliche Grundlagen und Entscheidungshilfen fuer den Bereich der Kompostierung und der Verwertung von biogenen Reststoffen, insbesondere der getrennt erfassten organischen Abfaelle aus den Haushaltungen (Bioabfall), zu schaffen. In diesem Rahmen sollen sowohl verschiedene Verfahren und Techniken der Kompostierung als auch regionale Konzepte hinsichtlich verfahrenstechnischer, hygienischer, oekologischer, oekonomischer und die Entsorgungssicherheit betreffender Aspekte untersucht und bewertet werden. (orig./SR)

  2. Part project 1. Methods and concepts of biological waste composting. Comparison - evaluation - recommendations; Teilbericht 1. Verfahren und Konzepte der Bioabfallkompostierung. Vergleich - Bewertung - Empfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Gronauer, A.; Helm, M.; Schoen, H. [Bayerische Landesanstalt fuer Landtechnik der Technischen Univ. Muenchen-Weihenstephan (Germany)

    1997-12-31

    Topics of this article are: composting of biological wastes; techniques, operation modes, regional concepts, engineering, hygienical, ecological, economical aspects. (SR) gardening plots. The project comprised three parts: Composting techniques, applications of compost in agriculture and gardening, and applications in landscaping. This volume comprises the summaries of the three part-projects. (orig./SR) [Deutsch] Das uebergeordnete Ziel des Weihenstephaner Verbundvorhabens bestand darin, fachliche Grundlagen und Entscheidungshilfen fuer den Bereich der Kompostierung und der Verwertung von biogenen Reststoffen, insbesondere der getrennt erfassten organischen Abfaelle aus den Haushaltungen (Bioabfall), zu schaffen. In diesem Rahmen sollen sowohl verschiedene Verfahren und Techniken der Kompostierung als auch regionale Konzepte hinsichtlich verfahrenstechnischer, hygienischer, oekologischer, oekonomischer und die Entsorgungssicherheit betreffender Aspekte untersucht und bewertet werden. (orig./SR)

  3. MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A.; Mueller-Lisse, U.G.; Massmann, J.

    2003-01-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [de

  4. Mr. Wolfgang Petritsch, Austrian Ambassador

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    Dr.Peter Schmid/CERN/EP, Dr.Wolfgang Petritsch, Austrian Ambassador, Permanent representative at UN, Mrs.Nora Petritsch, Dr.Kurt Hubner/CERN/AC, Mrs. Frederike Klaus-Salesin, Adviser, Mrs.Andrea Strohmeier, Secretary of the Ambassador, Mr.Heinz Klaus, Attaché, Dr.Theodor Tortschanoff/CERN/LHC, Mr.Peter Storer, Advisor. Dr.Peter Schmid/CERN/EP, Dr.Wolfgang Petritsch, Austrian Ambassador, Permanent representative at UN, Mrs.Nora Petritsch, Dr.Kurt Hubner/CERN/AC, Mrs. Frederike Klaus-Salesin, Adviser, Mrs.Andrea Strohmeier, Secretary of the Ambassador, Mr.Heinz Klaus, Attaché, Dr.Theodor Tortschanoff/CERN/LHC, Mr.Peter Storer, Advisor.

  5. Intracranial tuberculoma: MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, P; Zenteno, M A; Rodriguez-Carbajal, J; Brutto, O.H. del; Talamas, O

    1989-09-01

    MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, the potential role for MR diagnosis of intracranial tuberculoma is limited by the fact that other infectious or neoplasic diseases may present similar findings. The diagnosis of intracranial tuberculoma should rest on a proper integration of data from clinical manifestations, cerebrospinal fluid analysis, and neuroimaging studies. (orig.).

  6. Intracranial tuberculoma: MR imaging

    International Nuclear Information System (INIS)

    Salgado, P.; Zenteno, M.A.; Rodriguez-Carbajal, J.; Brutto, O.H. del; Talamas, O.

    1989-01-01

    MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, the potential role for MR diagnosis of intracranial tuberculoma is limited by the fact that other infectious or neoplasic diseases may present similar findings. The diagnosis of intracranial tuberculoma should rest on a proper integration of data from clinical manifestations, cerebrospinal fluid analysis, and neuroimaging studies. (orig.)

  7. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  8. Chondromalacia patellae: diagnosis with MR imaging.

    Science.gov (United States)

    McCauley, T R; Kier, R; Lynch, K J; Jokl, P

    1992-01-01

    Most previous studies of MR imaging for detection of chondromalacia have used T1-weighted images. We correlated findings on axial MR images of the knee with arthroscopic findings to determine MR findings of chondromalacia patellae on T2-weighted and proton density-weighted images. The study population included 52 patients who had MR examination of the knee with a 1.5-T unit and subsequent arthroscopy, which documented chondromalacia patellae in 29 patients and normal cartilage in 23. The patellar cartilage was assessed retrospectively for MR signal and contour characteristics. MR diagnosis based on the criteria of focal signal or focal contour abnormality on either the T2-weighted or proton density-weighted images yielded the highest correlation with the arthroscopic diagnosis of chondromalacia. When these criteria were used, patients with chondromalacia were detected with 86% sensitivity, 74% specificity, and 81% accuracy. MR diagnosis based on T2-weighted images alone was more sensitive and accurate than was diagnosis based on proton density-weighted images alone. In conclusion, most patients with chondromalacia patellae have focal signal or focal contour defects in the patellar cartilage on T2-weighted MR images. These findings are absent in most patients with arthroscopically normal cartilage.

  9. MR arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Trattnig, S.; Rand, T.; Breitenseher, M.; Ba-Ssalamah, A.; Schick, S.; Imhof, H.

    1999-01-01

    Due to its superior soft tissue contrast conventional MRI is the imaging method of choice in the evaluation of ankle joint disorders. Conventional MR imaging can accurately demonstrate normal or acutely injured ligaments; however, in subacute and chronic injury joint fluid necessary for delineation of injured ligaments is absent and MR arthrography should be performed. MR arthrography uses the intraarticular injection of contrast material to distend the joint, yielding improved discrimination of intraarticular structures. This joint distension with MR arthrography is also helpful in the staging of osteochondritis dissecans, since in cases of unstable lesions tracking of contrast material into the interface can be more easily demonstrated. Finally, high contrast and joint distension by MR arthrography improves the detection of intraarticular loose bodies, which often require surgery. MR artrography, although invasive, may provide additional information in various ankle joint disorders. (orig.) [de

  10. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J. Jr.; Engel, A. Jr.; Stiglbauer, R.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper reports on MR imaging which has gained increasing importance as a diagnostic instrument in orthopedics. The key to joint diagnostics - the evaluation of hyaline articular cartilage - however, has not been touched sufficiently by this development. Fundamental studies were done and 140 patients were examined with MR imaging after intraarticular administration of contrast agent. Hyaline cartilage, cruciate ligaments, and menisci were assessed before and after injection of a 2-mmol/L Gd-DTPA solution, and the results were compared with those of arthroscopy/arthrotomy. MR arthrography provided superior image quality compared with plain MR imaging. This resulted in an improved delineation of intraarticular structures, especially of cartilage defects

  11. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    modern uroradiology. (orig.) [German] Die MR-Urographie (MRU) und CT-Urographie (CTU) bieten differenzierte Darstellungsmoeglichkeiten der ableitenden Harnwege, die mit der intravenoesen Roentgenurographie (IVU) nicht erreicht werden. Die traditionelle MR-urographische Untersuchungstechnik verwendet unabhaengig von der renalen Ausscheidungsfunktion stark T{sub 2}-gewichtete Turbo-Spinecho-Seuqenzen fuer eine statische Wasserbildgebung und ist hervorragend zur Darstellung gestauter Harnwege geeignet, selbst bei stummen Nieren. Demgegenueber spiegelt die T{sub 1}-gewichtete Ausscheidungs-MRU die Nierenfunktion und die Abflussverhaeltnisse der Harnwege wider. Hierzu wird ein nierengaengiges gadoliniumhaltiges MR Kontrastmittel intravenoes verabreicht und der gadoliniumhaltige Harn mit schnellen T{sub 1}-gewichteten 3D-Gradientenecho-Sequenzen abgebildet. Die Kombination mit niedrigdosiertem Furosemid (5-10 mg i.v.) ist der Schluessel fuer eine homogene endoluminale Gadoliniumverteilung und zur Unterdrueckung von stoerenden Suszeptibilitaetsartefakten (T{sub 2}*-Effekte) in Harn. Die T{sub 1}-MRU ermoeglicht eindrucksvolle Urogramme der nicht dilatierten und maessiggradig gestauten Harnwege, sofern die Nierenfunktion nicht zu stark gestoert ist. Die Mehrschicht-CT Urography (MS-CTU) ist wie die T{sub 1}-MRU ebenfalls eine Ausscheidungsurographie. Auch bei der MS-CTU gewaehrleistet die Kombination mit niedrigdosiertem Furosemid eine verbesserte Kontrastmittelverteilung ohne Notwendigkeit einer abdominellen Kompression. Der Einsatz der CTU wird durch die Strahlenexposition und die Nephrotoxizitaet von Roentgenkontrastmitteln limitiert. Fuer die MRU und MS-CTU ergeben sich in Kombination mit einer konventionellen MRT oder CT zahlreiche Anwendungsmoeglichkeiten, z.B. bei intrinsischen und extrinsischen Tumorerkrankungen. Ferner empfiehlt sich die MRU zur Beurteilung von Transplantatnieren und ersetz mittlerweile in der paediatrischen Uroradiologie das Roentgen-IVU. Die MS

  12. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  13. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  14. MR investigation of recurrent cholesteatomas

    Energy Technology Data Exchange (ETDEWEB)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-03-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted.

  15. MR imaging of heterotopic gray matter; Heterotopia istoty szarej mozgu w obrazie MR

    Energy Technology Data Exchange (ETDEWEB)

    Kryst-Widzgowska, T.; Kozlowski, P.; Poniatowska, R. [Instytut Psychiatrii i Neurologii, Warsaw (Poland)

    1994-12-31

    Six patients with heterotopic gray matter were evaluated with MR. 5 patients had history of seizures. 4 cases were suspected of the cerebral tumor. In the MR examination areas of heterotopic gray matter were found along the posterior horn of the lateral ventricle on the one side in 4 cases and bilateraly in 2 cases. In 3 cases another brain abnormalities were also detected including: hypoplasia of corpus callosum, hypoplasia of brain hemisphere, cavum septi pellucidi. MR is a modality of choice in the assessment of abnormal gray matter migration. (author). 6 refs, 4 figs.

  16. Modern teaching for modern education

    OpenAIRE

    Mirascieva, Snezana

    2016-01-01

    Carrying the epithet of being contemporary education today means modern teaching. If modern education is a state in the field of education of all its elements, then teaching will also be a state with its own special features defining it as modern. The main issues of concern in this paper relate to what constitutes modern teaching, which features determine it as being modern, and how much is teaching today following the trend of modernization.

  17. Silencing MR-1 attenuates inflammatory damage in mice heart induced by AngII

    International Nuclear Information System (INIS)

    Dai, Wenjian; Chen, Haiyang; Jiang, Jiandong; Kong, Weijia; Wang, Yiguang

    2010-01-01

    Myofibrillogenesis regulator-1(MR-1) can aggravate cardiac hypertrophy induced by angiotensin(Ang) II in mice through activation of NF-κB signaling pathway, and nuclear transcription factor (NF)-κB and activator protein-1(AP-1) regulate inflammatory and immune responses by increasing the expression of specific inflammatory genes in various tissues including heart. Whether inhibition of MR-1 expression will attenuate AngII-induced inflammatory injury in mice heart has not been explored. Herein, we monitored the activation of NF-κB and AP-1, together with expression of pro-inflammatory of interleukin(IL)-6, tumor necrosis factor(TNF)-α, vascular-cell adhesion molecule (VCAM)-1, platelet endothelial cell adhesion molecule (PECAM), and inflammatory cell infiltration in heart of mice which are induced firstly by AngII (PBS),then received MR-1-siRNA or control-siRNA injecting. We found that the activation of NF-κB and AP-1 was inhibited significantly, together with the decreased expression of IL-6, TNF-α, VCAM-1, and PECAM in AngII-induced mice myocardium in MR-1-siRNA injection groups compared with control-siRNA injecting groups. However, the expression level of MR-1 was not an apparent change in PBS-infused groups than in unoperation groups, and MR-1-siRNA do not affect the expression of MR-1 in PBS-infused mice. Our findings suggest that silencing MR-1 protected mice myocardium against inflammatory injury induced by AngII by suppression of pro-inflammatory transcription factors NF-κB and AP-1 signaling pathway.

  18. Amnestic mild cognitive impairment: functional MR imaging study of response in posterior cingulate cortex and adjacent precuneus during problem-solving tasks.

    Science.gov (United States)

    Jin, Guangwei; Li, Kuncheng; Hu, Yingying; Qin, Yulin; Wang, Xiangqing; Xiang, Jie; Yang, Yanhui; Lu, Jie; Zhong, Ning

    2011-11-01

    To compare the blood oxygen level-dependent (BOLD) response, measured with functional magnetic resonance (MR) imaging, in the posterior cingulate cortex (PCC) and adjacent precuneus regions between healthy control subjects and patients with amnestic mild cognitive impairment (MCI) during problem-solving tasks. This study was approved by the institutional review board. Each subject provided written informed consent. Thirteen patients with amnestic MCI and 13 age- and sex-matched healthy control subjects participated in the study. The functional magnetic resonance (MR) imaging tasks were simplified 4 × 4-grid number placement puzzles that were divided into a simple task (using the row rule or the column rule to solve the puzzle) and a complex task (using both the row and column rules to solve the puzzle). Behavioral results and functional imaging results between the healthy control group and the amnestic MCI group were analyzed. The accuracy for the complex task in the healthy control group was significantly higher than that in the amnestic MCI group (P < .05). The healthy control group exhibited a deactivated BOLD signal intensity (SI) change in the bilateral PCC and adjacent precuneus regions during the complex task, whereas the amnestic MCI group showed activation. The positive linear correlations between the BOLD SI change in bilateral PCC and adjacent precuneus regions and in bilateral hippocampi in the amnestic MCI group were significant (P < .001), while in the healthy control group, they were not (P ≥ .23). These findings suggest that an altered BOLD response in amnestic MCI patients during complex tasks might be related to a decline in problem-solving ability and to memory impairment and, thus, may indicate a compensatory response to memory impairment. RSNA, 2011

  19. Serial MR imaging and 1H-MR spectroscopy in monozygotic twins with Tay-Sachs disease.

    Science.gov (United States)

    Imamura, A; Miyajima, H; Ito, R; Orii, K O

    2008-10-01

    Four-year-old monozygotic female twins with early onset Tay-Sachs disease are described. The sisters showed similar slowly progressive clinical symptoms and deterioration, however the younger sister also demonstrated intractable myoclonus in the right leg. The serial MR images and (1)H-MR spectroscopy of the brain were obtained in both twins. MR images showed high intensity on T (2)-weighted image in the bilateral white matter, however there were no signal changes in the basal ganglia and thalamus during any of the phases. The ratio of N-acetylaspartate (NAA)/creatine (Cr) was decreased in the both white matter lesions and the corpus striatum, and that of myoinositol (mI)/Cr was increased in the damaged white matter on MR spectroscopy. The elevation of the lactate peak was clearly demonstrated in the left basal ganglia of the younger sister; however it was not shown in cerebral lesions of the elder sister. Changes in metabolites on MR spectroscopy were closely linked to the respective clinical features of each twin. Follow-up examination by (1)H-MR spectroscopy is useful for the evaluation of neuronal changes in children with Tay-Sachs disease.

  20. Classification of bones from MR images in torso PET-MR imaging using a statistical shape model

    International Nuclear Information System (INIS)

    Reza Ay, Mohammad; Akbarzadeh, Afshin; Ahmadian, Alireza; Zaidi, Habib

    2014-01-01

    There have been exclusive features for hybrid PET/MRI systems in comparison with its PET/CT counterpart in terms of reduction of radiation exposure, improved soft-tissue contrast and truly simultaneous and multi-parametric imaging capabilities. However, quantitative imaging on PET/MR is challenged by attenuation of annihilation photons through their pathway. The correction for photon attenuation requires the availability of patient-specific attenuation map, which accounts for the spatial distribution of attenuation coefficients of biological tissues. However, the lack of information on electron density in the MR signal poses an inherent difficulty to the derivation of the attenuation map from MR images. In other words, the MR signal correlates with proton densities and tissue relaxation properties, rather than with electron density and, as such, it is not directly related to attenuation coefficients. In order to derive the attenuation map from MR images at 511 keV, various strategies have been proposed and implemented on prototype and commercial PET/MR systems. Segmentation-based methods generate an attenuation map by classification of T1-weighted or high resolution Dixon MR sequences followed by assignment of predefined attenuation coefficients to various tissue types. Intensity-based segmentation approaches fail to include bones in the attenuation map since the segmentation of bones from conventional MR sequences is a difficult task. Most MR-guided attenuation correction techniques ignore bones owing to the inherent difficulties associated with bone segmentation unless specialized MR sequences such as ultra-short echo (UTE) sequence are utilized. In this work, we introduce a new technique based on statistical shape modeling to segment bones and generate a four-class attenuation map. Our segmentation approach requires a torso bone shape model based on principle component analysis (PCA). A CT-based training set including clearly segmented bones of the torso region

  1. A comparison of chemoembolization endpoints using angiographic versus transcatheter intraarterial perfusion/MR imaging monitoring.

    Science.gov (United States)

    Lewandowski, Robert J; Wang, Dingxin; Gehl, James; Atassi, Bassel; Ryu, Robert K; Sato, Kent; Nemcek, Albert A; Miller, Frank H; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Salem, Riad; Omary, Reed A

    2007-10-01

    Transcatheter arterial chemoembolization (TACE) is an established treatment for unresectable liver cancer. This study was conducted to test the hypothesis that angiographic endpoints during TACE are measurable and reproducible by comparing subjective angiographic versus objective magnetic resonance (MR) endpoints of TACE. The study included 12 consecutive patients who presented for TACE for surgically unresectable HCC or progressive hepatic metastases despite chemotherapy. All procedures were performed with a dedicated imaging system. Angiographic series before and after TACE were reviewed independently by three board-certified interventional radiologists. A subjective angiographic chemoembolization endpoint (SACE) classification scheme, modified from an established angiographic grading system in the cardiology literature, was designed to assist in reproducibly classifying angiographic endpoints. Reproducibility in SACE classification level was compared among operators, and MR imaging perfusion reduction was compared with SACE levels for each observer. Twelve patients successfully underwent 15 separate TACE sessions. SACE levels ranged from I through IV. There was moderate agreement in SACE classification (kappa = 0.46 +/- 0.12). There was no correlation between SACE level and MR perfusion reduction (r = 0.16 for one operator and 0.02 for the other two). Angiographic endpoints during TACE vary widely, have moderate reproducibility among operators, and do not correlate with functional MR imaging perfusion endpoints. Future research should aim to determine ideal angiographic and functional MR imaging endpoints for TACE according to outcome measures such as imaging response, pathologic response, and survival.

  2. Breast cancer staging with MR imaging

    International Nuclear Information System (INIS)

    Smathers, R.L.; D'Amelio, F.; Stockdale, F.

    1989-01-01

    Forty-three patients with biopsy-proved breast cancer underwent MR staging of the cervicothoracic spine, lumbosacral spine, liver, and thorax. In all cases, these findings have been compared with the results of clinical staging, laboratory tests, chest radiography, and radionuclide bone scanning. MR imaging was a valuable staging tool for patients with more than minimal breast cancer and indications for radionuclide bone scanning. MR imaging had the greatest clinical importance when it identified thoracic soft-tissue abnormalities, including axillary., lateral thoracic, supraclavicular, and mediastinal lymphadenopathy. The coronal and sagittal views were very valuable for detection of chest wall invasion, sternal involvement, and internal mammary adenopathy. Negative MR staging clinically reassured patients that aggressive local therapy bad curative potential. Positive MR staging avoided inappropriate aggressive local therapy and mastectomy. MR imaging can be recommended for improved breast cancer staging in patients with newly diagnosed breast cancer who have more than minimal disease

  3. Hemato-oncological imaging. Importance of hybrid procedures; Haematoonkologische Bildgebung. Stellenwert der Hybridverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Mayerhoefer, M.E. [Univ.-Klinik fuer Radiologie und Nuklearmedizin, Abteilung fuer Allgemeine und Kinderradiologie, Medizinische Universitaet Wien, Wien (Austria); Haug, A. [Univ.-Klinik fuer Radiologie und Nuklearmedizin, Abteilung fuer Nuklearmedizin, Medizinische Universitaet Wien, Wien (Austria)

    2016-07-15

    Biomedical imaging procedures play a major role in hemato-oncological diseases with respect to pre-therapeutic staging and assessment of treatment response. Originally, the therapeutic management was the domain of computed tomography (CT) and whole-body magnetic resonance imaging (MRI). Over the last decade these purely morphological techniques have gradually been replaced by hybrid imaging techniques, such as positron emission tomography-CT (PET/CT) and PET/MRI, which also provide metabolic and functional information. For lymphomas, the PET tracer 18F-fluorodeoxyglucose (18 F-FDG) is meanwhile so well-established that its use is a cornerstone of the Lugano classification; however, for multiple myeloma the search for an optimal PET tracer that can also detect early disease stages is still ongoing. Functional MRI techniques, such as diffusion-weighted imaging (DWI), perfusion-weighted imaging and dynamic contrast-enhanced imaging have shown promising results for both lymphomas and multiple myelomas. The PET/MRI technique can combine the different types of information due to its truly multiparametric approach. In the future PET/MRI could possibly become the hybrid imaging technique of choice for hemato-oncological diseases. (orig.) [German] Bildgebende Verfahren spielen bei haematoonkologischen Erkrankungen eine wesentliche Rolle fuer das Staging vor der Therapie und die Beurteilung des Therapieansprechens. Urspruenglich waren es v. a. die CT und die Ganzkoerper-MRT, welche die fuer das therapeutische Management relevanten Informationen lieferten. Im letzten Jahrzehnt erfolgte bei dieser Gruppe von Tumorerkrankungen jedoch eine Abkehr von den rein morphologischen Verfahren hin zu den Hybridverfahren Positronenemissionstomographie(PET)-CT und PET-MRT, welche auch metabolische und funktionelle Informationen liefern. Bei Lymphomen steht der PET-Tracer {sup 18}F-Fluordesoxyglukose ({sup 18}F-FDG) mittlerweile im Zentrum der Diagnostik und ist auch fest in der aktuellen

  4. New aspects of MRI for diagnostics of large vessel vasculitis and primary angiitis of the central nervous system; Neue Aspekte der MRT-Bildgebung zur Diagnostik der Grossgefaessvaskulitiden sowie der primaeren Angiitis des zentralen Nervensystems

    Energy Technology Data Exchange (ETDEWEB)

    Saam, T.; Habs, M.; Cyran, C.C.; Grimm, J.; Reiser, M.F.; Nikolaou, K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Pfefferkorn, T. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Neurologie, Muenchen (Germany); Schueller, U. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Zentrum fuer Neuropathologie, Muenchen (Germany)

    2010-10-15

    Vasculitis is a rare disease and clinical symptoms are often unspecific. Accurate and early diagnosis is mandatory in order to prevent complications, such as loss of vision or stroke. Imaging techniques can contribute to establishing a definite diagnosis and to evaluate disease activity and the extent of the disease in various vascular regions. Conventional imaging methods, such as computed tomography (CT) and magnetic resonance (MR) angiography, as well as digital subtraction angiography allow the vessel lumen but not the vessel wall to be depicted. However, vasculitis is a disease which primarily affects the vessel wall, therefore conventional imaging modalities often fail to make a definite diagnosis. Recently black-blood high resolution MR in vivo imaging has been used to visualize cervical and intracranial vasculitis. This review article presents imaging protocols for intracranial and cervical black-blood MR imaging and clinical cases with large vessel vasculitis and vasculitis of the central nervous system. Furthermore the current literature, examples of the most common differential diagnoses of cervical and cranial arteriopathy and the potential of other imaging modalities, such as PET/CT and ultrasound will be discussed. (orig.) [German] Vaskulitiden sind seltene Erkrankungen, deren klinische Symptome oft unspezifisch sind und deren genaue und fruehzeitige Diagnose daher eine besondere Herausforderung fuer jeden Kliniker darstellt. Hierzu kann die Bildgebung einen wertvollen Beitrag leisten und ist insbesondere in der Lage, das Ausmass der Erkrankung und die Anzahl der betroffenen Gefaesse zu bestimmen. Die klassischen bildgebenden Verfahren wie CT- (CTA) oder MR-Angiographie (MRA) sowie die digitale Subtraktionsangiographie (DSA) fokussieren dabei hauptsaechlich auf Veraenderungen des Lumendurchmessers, die Gefaesswand wird mit diesen Verfahren in der Regel nur unzureichend dargestellt. Ultraschalluntersuchungen lassen zwar eine Beurteilung des Lumens und

  5. Clinical stage T1c prostate cancer: evaluation with endorectal MR imaging and MR spectroscopic imaging.

    Science.gov (United States)

    Zhang, Jingbo; Hricak, Hedvig; Shukla-Dave, Amita; Akin, Oguz; Ishill, Nicole M; Carlino, Lauren J; Reuter, Victor E; Eastham, James A

    2009-11-01

    To assess the diagnostic accuracy of endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for prediction of the pathologic stage of prostate cancer and the presence of clinically nonimportant disease in patients with clinical stage T1c prostate cancer. The institutional review board approved-and waived the informed patient consent requirement for-this HIPAA-compliant study involving 158 patients (median age, 58 years; age range, 40-76 years) who had clinical stage T1c prostate cancer, had not been treated preoperatively, and underwent combined 1.5-T endorectal MR imaging-MR spectroscopic imaging between January 2003 and March 2004 before undergoing radical prostatectomy. On the MR images and combined endorectal MR-MR spectroscopic images, two radiologists retrospectively and independently rated the likelihood of cancer in 12 prostate regions and the likelihoods of extracapsular extension (ECE), seminal vesicle invasion (SVI), and adjacent organ invasion by using a five-point scale, and they determined the probability of clinically nonimportant prostate cancer by using a four-point scale. Whole-mount step-section pathology maps were used for imaging-pathologic analysis correlation. Receiver operating characteristic curves were constructed and areas under the curves (AUCs) were estimated nonparametrically for assessment of reader accuracy. At surgical-pathologic analysis, one (0.6%) patient had no cancer; 124 (78%) patients, organ-confined (stage pT2) disease; 29 (18%) patients, ECE (stage pT3a); two (1%) patients, SVI (stage pT3b); and two (1%) patients, bladder neck invasion (stage pT4). Forty-six (29%) patients had a total tumor volume of less than 0.5 cm(3). With combined MR imaging-MR spectroscopic imaging, the two readers achieved 80% accuracy in disease staging and AUCs of 0.62 and 0.71 for the prediction of clinically nonimportant cancer. Clinical stage T1c prostate cancers are heterogeneous in pathologic stage and volume. MR imaging may

  6. Rickets on MR images

    International Nuclear Information System (INIS)

    Ecklund, K.; Jaramillo, D.; Doria, A.S.

    1999-01-01

    Background. The pathologic changes at the physis in patients with rickets have been well demonstrated histologically. Radiographs can depict only the associated osseous abnormalities. Patients and methods. We report two children in whom MR imaging demonstrated rachitic changes in the physeal cartilage beyond the well-recognized bony features. Results. The striking appearance of the physes and the physes of the secondary ossification centers confirm that MR imaging can successfully evaluate the cartilaginous structures of the developing skeleton. Conclusion. Though MR imaging is clearly unnecessary for the diagnosis of rickets, it is important that the typical features are not misinterpreted as other pathology. (orig.)

  7. PET/MR in oncology

    DEFF Research Database (Denmark)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin

    2012-01-01

    of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number...... be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new...

  8. MR investigation of recurrent cholesteatomas

    International Nuclear Information System (INIS)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-01-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted [fr

  9. Mannose Receptor Mediates the Immune Response to Ganoderma atrum Polysaccharides in Macrophages.

    Science.gov (United States)

    Li, Wen-Juan; Tang, Xiao-Fang; Shuai, Xiao-Xue; Jiang, Cheng-Jia; Liu, Xiang; Wang, Le-Feng; Yao, Yu-Fei; Nie, Shao-Ping; Xie, Ming-Yong

    2017-01-18

    The ability of mannose receptor (MR) to recognize the carbohydrate structures is well-established. Here, we reported that MR was crucial for the immune response to a Ganoderma atrum polysaccharide (PSG-1), as evidenced by elevation of MR in association with increase of phagocytosis and concentrations of interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) in normal macrophages. Elevation of MR triggered by PSG-1 also led to control lipopolysaccharide (LPS)-triggered inflammatory response via the increase of interleukin-10 (IL-10) and inhibition of phagocytosis and IL-1β. Anti-MR antibody partly attenuated PSG-1-mediated anti-inflammatory responses, while it could not affect TNF-α secretion, suggesting that another receptor was involved in PSG-1-triggered immunomodulatory effects. MR and toll-like receptor (TLR)4 coordinated the influences on the TLR4-mediated signaling cascade by the nuclear factor-κB (NF-κB) pathway in LPS-stimulated macrophages subjected to PSG-1. Collectively, immune response to PSG-1 required recognition by MR in macrophages. The NF-κB pathway served as a central role for the coordination of MR and TLR4 to elicit immune response to PSG-1.

  10. Potential of MR histogram analyses for prediction of response to chemotherapy in patients with colorectal hepatic metastases.

    Science.gov (United States)

    Liang, He-Yue; Huang, Ya-Qin; Yang, Zhao-Xia; Ying-Ding; Zeng, Meng-Su; Rao, Sheng-Xiang

    2016-07-01

    To determine if magnetic resonance imaging (MRI) histogram analyses can help predict response to chemotherapy in patients with colorectal hepatic metastases by using response evaluation criteria in solid tumours (RECIST1.1) as the reference standard. Standard MRI including diffusion-weighted imaging (b=0, 500 s/mm(2)) was performed before chemotherapy in 53 patients with colorectal hepatic metastases. Histograms were performed for apparent diffusion coefficient (ADC) maps, arterial, and portal venous phase images; thereafter, mean, percentiles (1st, 10th, 50th, 90th, 99th), skewness, kurtosis, and variance were generated. Quantitative histogram parameters were compared between responders (partial and complete response, n=15) and non-responders (progressive and stable disease, n=38). Receiver operator characteristics (ROC) analyses were further analyzed for the significant parameters. The mean, 1st percentile, 10th percentile, 50th percentile, 90th percentile, 99th percentile of the ADC maps were significantly lower in responding group than that in non-responding group (p=0.000-0.002) with area under the ROC curve (AUCs) of 0.76-0.82. The histogram parameters of arterial and portal venous phase showed no significant difference (p>0.05) between the two groups. Histogram-derived parameters for ADC maps seem to be a promising tool for predicting response to chemotherapy in patients with colorectal hepatic metastases. • ADC histogram analyses can potentially predict chemotherapy response in colorectal liver metastases. • Lower histogram-derived parameters (mean, percentiles) for ADC tend to have good response. • MR enhancement histogram analyses are not reliable to predict response.

  11. The semidry acid-anhydrite process (the use of flue gas desulphurization (FGD) gypsum by development of a new process for the production of FGD anhydrite); Das quasitrockene Saeure-Anhydrit-Verfahren (Erweiterung der Verwendungsmoeglichkeiten von REA-Gips durch Entwicklung eines Verfahrens zur Herstellung von REA-Anhydrit aus REA-Gips)

    Energy Technology Data Exchange (ETDEWEB)

    Wirsching, F. [Gebr. Knauf, Westdeutsche Gipswerke, Iphofen (Germany); Hueller, R. [Gebr. Knauf, Westdeutsche Gipswerke, Iphofen (Germany); Limmer, B. [Gebr. Knauf, Westdeutsche Gipswerke, Iphofen (Germany)

    1994-10-01

    -Anhydrit untersucht. Die Reaktion erfolgt mit feuchtem, feinteiligem REA-Gips unter der katalytischen Wirkung kleiner Mengen Schwefelsaeure bei Temperaturen um 100 bis 200 C. Es wird wasserfreier REA-Anhydrit mit orthorhombischer Kristallstruktur erhalten. Die Umwandlung des Kristallgitters von Calciumsulfat-Dihydrat in Calciumsulfat-Anhydrit II vollzieht sich dabei direkt durch Mineralneubildung. Diese Umwandlung wird zu einem Verfahren entwickelt und als `Quasitrockenes Saeure-Anydrit-Verfahren` bezeichnet. Die Reaktion und ihr Mechanismus wurde zuerst in Laborversuchen untersucht. Als Ausgangsstoff ist jedes feinteilige Calciumsulfat-Dihydrat geeignet. Der bereits im Kraftwerk feinteilig-kristallin erzeugte REA-Gips mit 10% Restfeuchte ist besonders vorteilhaft, da er fuer diese Verwendung vorher nicht getrocknet und nicht gemahlen werden muss. Die Verfahrensentwicklung wurde bis in den halbtechnischen Massstab durchgefuehrt und Auslegungsgrundlagen fuer Grossanlagen an Kraftwerksstandorten erarbeitet. Als Reaktionsaggregat zeigte sich der direkt beheizte Drehrohrofen geeignet. Der REA-Anhydrit wird in diesem Verfahren als trockenes feinteiliges Produkt mit reproduzierbaren Teilchengroessen um 2 Mikron erhalten und besitzt neuartige technologische Eigenschaften. Seine Verwendungsmoeglichkeit wurde fuer die Zementindustrie sowie als Rohstoff zur Herstellung von Fuellstoffen untersucht. Fuer die Zementindustrie ist er grundsaetzlich geeignet. Der Einsatz als Fuellstoff ermoeglicht eine erweiterte Verwendung des REA-Gipses ausserhalb der traditionellen Bereiche der Gipsindustrie. Erste Versuche erlauben die Schlussfolgerung, dass der REA-Anhydrit nach einer Aufbereitung, die ebenfalls labormaessig neu entwickelt wurde, die fuer einen hochwertigen Fuellstoff notwendigen guten Eigenschaftsmerkmale hat. (orig.)

  12. MR imaging of pituitary dwarfism

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Muramatsu, Masayuki; Inoue, Yusuke

    1993-01-01

    Pituitary MR imaging was performed in 32 patients with clinically diagnosed pituitary dwarfism and 12 normal controls. The patients were divided into two groups according to the severity of pituitary dwarfism based on endocrinological data. The two patients with severe dwarfism showed transection of the pituitary stalk, ectopic posterior lobe and atrophy of the anterior lobe on MR imaging, while the 27 patients with mild dwarfism showed no abnormal MR findings of the pituitary gland. The former group corresponds to typical pituitary dwarfism and the latter to partial GH deficiency, which was recently proposed as another type of pituitary dwarfism. In conclusion, pituitary MR imaging may differentiate partial GH deficiency from typical (stalk-transected) pituitary dwarfism. (author)

  13. MR imaging of pituitary dwarfism

    Energy Technology Data Exchange (ETDEWEB)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Muramatsu, Masayuki; Inoue, Yusuke (Saitama Medical School, Kawagoe (Japan). Medical Center)

    1993-02-01

    Pituitary MR imaging was performed in 32 patients with clinically diagnosed pituitary dwarfism and 12 normal controls. The patients were divided into two groups according to the severity of pituitary dwarfism based on endocrinological data. The two patients with severe dwarfism showed transection of the pituitary stalk, ectopic posterior lobe and atrophy of the anterior lobe on MR imaging, while the 27 patients with mild dwarfism showed no abnormal MR findings of the pituitary gland. The former group corresponds to typical pituitary dwarfism and the latter to partial GH deficiency, which was recently proposed as another type of pituitary dwarfism. In conclusion, pituitary MR imaging may differentiate partial GH deficiency from typical (stalk-transected) pituitary dwarfism. (author).

  14. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  15. Whole heart cine MR imaging of pulmonary veins in patients with congenital heart disease. Comparison with Spin Echo MR imaging

    International Nuclear Information System (INIS)

    Mitsui, Hideaki; Saito, Haruo; Ishibashi, Tadashi; Takahashi, Shoki; Zuguchi, Masayuki; Yamada, Shogo

    2002-01-01

    We evaluated the accuracy of Whole Heart Cine (WHC) magnetic resonance (MR) imaging in the depiction of pulmonary veins (PVs) in patients with congenital heart disease (CHD) compared to that of spin echo (SE) MR imaging. Among our 35 patients, 4 patients had anomalous PV return. Detectability of four PVs on each MR examination images were evaluated. MR imaging is an effective modality for the clarification of PVs, and WHC MR imaging is more useful in delineating PV anomalies than SE MR imaging. (author)

  16. MR-urography and CT-urography: principles, examination techniques, applications

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Adam, G.; Staatz, G.; Wildberger, J.

    2003-01-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T 2 -weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T 2 -weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T 1 -weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T 1 -weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T 2 *-effects) in the urine. T 1 -weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T 1 -weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in modern uroradiology. (orig

  17. Differential MR/GR Activation in Mice Results in Emotional States Beneficial or Impairing for Cognition

    Directory of Open Access Journals (Sweden)

    Vera Brinks

    2007-01-01

    Full Text Available Corticosteroids regulate stress response and influence emotion, learning, and memory via two receptors in the brain, the high‐affinity mineralocorticoid (MR and low‐affinity glucocorticoid receptor (GR. We test the hypothesis that MR- and GR-mediated effects interact in emotion and cognition when a novel situation is encountered that is relevant for a learning process. By adrenalectomy and additional constant corticosterone supplement we obtained four groups of male C57BL/6J mice with differential chronic MR and GR activations. Using a hole board task, we found that mice with continuous predominant MR and moderate GR activations were fast learners that displayed low anxiety and arousal together with high directed explorative behavior. Progressive corticosterone concentrations with predominant action via GR induced strong emotional arousal at the expense of cognitive performance. These findings underline the importance of a balanced MR/GR system for emotional and cognitive functioning that is critical for mental health.

  18. MR and CT for malignant hypernephromas

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Fischer, C.; Ruehl, G.; Beyer, H.K.; Hummelsheim, P.; Bochum Univ.; Marienhospital, Herne; Bochum Univ.

    1987-01-01

    Forty patients with histologically confirmed hypernephromas were examined by MR and CT. As regards T-staging, MR had an accuracy of 97 % and CT of 91%; for N-staging, MR had an accuracy of 85% and CT of 91% and, with regard to infiltration of the renal vein, MR was correct in 88% of cases and CT in 81%. MR was most accurate in the pre-operative assessment of tumour spread, demonstrating caval involvement in 100% and lymph node metastases in 97%. On the other hand, infiltration of the renal pelvis could be assessed in only 65% of cases; in 27% the assessment was not possible and in 8% one could not be certain. CT proved to be at its best for staging of lymph nodes, but in 15% it was not possible to identify infiltration of the renal vein. MR was not greatly superior to CT in the preoperative diagnosis and staging of hypernephromas. (orig.) [de

  19. Assessment of the responses to neoadjuvant chemotherapy of osteosarcoma by diffusion-weighted MR image: initial results

    International Nuclear Information System (INIS)

    Shu Min; Du Lianjun; Ding Xiaoyi; Lu Yong; Yan Ling; Jiang Hao; Chen Kemin

    2009-01-01

    Objective: To determine the utility of diffusion-weighted magnetic resonance imaging (MR DWI) in detecting tumor necrosis with histological correlation after neoadjuvant chemotherapy. Methods: Conventional MRI and DWI were obtained from 36 patients with histological proven osteosarcoma. Magnetic resonance examinations were performed in all patients before and after 4 cycles of preoperative neoadjuvant chemotherapy. Apparent diffusion coefficients (ADC) were calculated. The degree of tumor necrosis was assessed using the histological Huvos classification after chemotherapy. t-test was performed for testing changes in ADC value between the 2 groups. P value less than 0.05 were considered as a statistically significant difference. Results: The differences in ADC between viable [(1.06 ± 0.30)x10 -3 mm 2 /s] and necrotic [(2.39 ± 0.44)x10 -3 mm 2 /s] tumor were significant (t = 3.515, P -3 mm 2 /s to (2.27 ± 0.20)x10 -3 mm 2 s, the corresponding value in poor responses was increased from (1.45 ± 0.11)x10 -3 mm 2 /s to (1.83 ± 0.16)x10 -3 mm 2 /s. There was significant difference in changes of ADC values between good responses and poor responses (t = 4.981, P < 0.01). Conclusion: Diffusion-weighted MRI permits recognition of tumor necrosis induced by chemotherapy in osteosarcoma. DWI is correlated directly with tumor necrosis. They have potential utility in evaluating the preoperative chemotherapy response in patients with primary osteosarcoma. (authors)

  20. Fast high-resolution MR imaging using the snapshot-FLASH MR sequence

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Henrich, D.; Duhmke, E.

    1990-01-01

    Snapshot, fast low-angle short (FLASH) MR imaging using an accelerated FLASH-MR sequence provides MR images with measuring times far below 1 second. The short TE of this sequence prevents susceptibility artifacts in gradient-echo imaging. In this paper variations of the sequence are shown that provide high resolution images with T1-weighted IR, T2-weighted SE, and chemical shift (CHESS) contrast sequences. METHODS AND MATERIALS: A whole-body 2-T system (Bruker-Medizintechnik) were used in combination with a 60-cm gradient system (providing gradient strength of 5 mT/m) to study healthy volunteers. The measuring time for a 256 x 256 image matrix was 800 msec. This sequence has been used in combination with T1-weighted IR, T2-weighted SE, and CHESS variations

  1. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    International Nuclear Information System (INIS)

    Neuner, Irene; Kaffanke, Joachim B.; Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans; Shah, N. Jon

    2012-01-01

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as 18 F-fluoroethyl-l-tyrosine (FET) or 11 C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  2. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, Irene [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Psychiatry, Psychotherapy and Psychosomatics, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany); Kaffanke, Joachim B. [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); MR-Transfer e.K., Wuppertal (Germany); Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); Shah, N. Jon [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Neurology, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany)

    2012-12-15

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as {sup 18}F-fluoroethyl-l-tyrosine (FET) or {sup 11}C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  3. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  4. Postictal MR-changes. A rare and important differential diagnosis; Postiktale MR-Veraenderungen. Eine seltene und wichtige Differenzialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Hattingen, E.; Raab, P.; Lanfermann, H.; Zanella, F.E.; Weidauer, S. [Johann-Wolfgang-Goethe-Universitaet Frankfurt/Main, Institut fuer Neuroradiologie, Frankfurt (Germany)

    2008-11-15

    Postictal MR findings are analyzed in the context of MR morphological differential diagnoses. Postictal MRI was performed in 11 patients. The patterns of MR changes and their differential diagnoses were analyzed. Focal accentuation of signal increase in the cortex was found on T2-weighted images in 90% of these cases, pial enhancement in 70% and signal changes of the pulvinar/thalamus in 40%. The most common differential diagnoses were encephalitis, and in tumor patients carcinomatous involvement of the meninges. Postictal MR changes vary widely and are difficult to differentiate from illnesses such as encephalitis and carcinomatosis involving the meninges. Nevertheless, knowledge of the typical pattern of postictal MR findings and the clinical course may help to avoid mistaken diagnoses. (orig.) [German] Postiktale MR-Veraenderungen werden im Kontext ihrer Differenzialdiagnosen analysiert. Elf Patienten wurden postiktal im MRT untersucht. Ausgewertet wurden die MR-tomographischen Befundmuster und ihre Differenzialdiagnosen. Bei 90% der Patienten fanden sich fokale kortikal betonte Signalsteigerungen in der T2-Wichtung, bei 90% Diffusionseinschraenkungen, bei 70% piale Anreicherungen und bei 40% Signalalterationen des Pulvinars/Thalamus. Haeufigste Differenzialdiagnosen waren die Enzephalitis und bei entsprechender Tumoranamnese die Meningeosis carcinomatosa. Postiktale MR-Veraenderungen sind vielgestaltig und nicht immer leicht von Erkrankungen wie insbesondere der Enzephalitis oder der Meningeosis carcinomatosa zu unterscheiden. Dennoch helfen die Kenntnis typischer postiktaler Befallsmuster und der klinische Verlauf, Fehldiagnosen zu vermeiden. (orig.)

  5. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  6. MR imaging of persistent primitive trigeminal artery

    International Nuclear Information System (INIS)

    Ashikaga, Ryuichiro; Araki, Yutaka; Ono, Yukihiko; Ishida, Osamu; Mabuchi, Nobuhisa.

    1997-01-01

    The persistent trigeminal artery is the most common anomaly of the primitive carotid-vertebrobasilar anastomoses. We reviewed MR images and MR angiographies of 11 patients with primitive trigeminal artery. In 8 of the 11 cases, PTA were identified with conventional long TR spin-echo images. In 8 of 11 cases, a hypoplastic basilar trunk associated with PTA was seen on both MR images and MR angiographies. In 7 of 11 cases, a hypoplasia or agenesis of the ipsilateral posterior communicating artery was seen on MR angiographies. (author)

  7. 77 FR 65545 - Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption

    Science.gov (United States)

    2012-10-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 4815-009] Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption 1. By application filed on July 30, 2012 and supplemented on August 14, 2012, Mr. Jesse S. Capel and Mr. Hilton J. Cochran and EWP...

  8. Molecular MR Imaging Probes

    OpenAIRE

    MAHMOOD, UMAR; JOSEPHSON, LEE

    2005-01-01

    Magnetic resonance imaging (MRI) has been successfully applied to many of the applications of molecular imaging. This review discusses by example some of the advances in areas such as multimodality MR-optical agents, receptor imaging, apoptosis imaging, angiogenesis imaging, noninvasive cell tracking, and imaging of MR marker genes.

  9. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  10. MR-based field-of-view extension in MR/PET: B0 homogenization using gradient enhancement (HUGE).

    Science.gov (United States)

    Blumhagen, Jan O; Ladebeck, Ralf; Fenchel, Matthias; Scheffler, Klaus

    2013-10-01

    In whole-body MR/PET, the human attenuation correction can be based on the MR data. However, an MR-based field-of-view (FoV) is limited due to physical restrictions such as B0 inhomogeneities and gradient nonlinearities. Therefore, for large patients, the MR image and the attenuation map might be truncated and the attenuation correction might be biased. The aim of this work is to explore extending the MR FoV through B0 homogenization using gradient enhancement in which an optimal readout gradient field is determined to locally compensate B0 inhomogeneities and gradient nonlinearities. A spin-echo-based sequence was developed that computes an optimal gradient for certain regions of interest, for example, the patient's arms. A significant distortion reduction was achieved outside the normal MR-based FoV. This FoV extension was achieved without any hardware modifications. In-plane distortions in a transaxially extended FoV of up to 600 mm were analyzed in phantom studies. In vivo measurements of the patient's arms lying outside the normal specified FoV were compared with and without the use of B0 homogenization using gradient enhancement. In summary, we designed a sequence that provides data for reducing the image distortions due to B0 inhomogeneities and gradient nonlinearities and used the data to extend the MR FoV. Copyright © 2011 Wiley Periodicals, Inc.

  11. Substantia nigra in MR images in Parkinson disease and MPTP exposure

    International Nuclear Information System (INIS)

    De La Paz, R.L.; Duguid, J.; Langston, W.J.

    1986-01-01

    Eight patients, aged 60-77 years, with idiopathic Parkinson disease were studied to determine whether the characteristic degeneration of the substantia nigra (zona compacta), seen pathologically, could be identified in vivo on T2-weighted proton MR imaging (1.5 T). The mean width of the substantia nigra in the eight patients was 4.1 mm (SEM = 0.21 mm), significantly (rho < .004) less than the mean width of 5.2 mm (SEM= 0.30 mm) in ten age-matched controls. Overlap with control values was seen in only one patient. No clear correlation between low signal in the putamen (suggesting excess deposition of iron, Fe/sup 3+/) and Parkinson disease was seen. Narrowing of the substantia nigra on MR imaging was also seen in one patient with drug-induced Parkinson syndrome (MPTP exposure). These changes on MR imaging are probably due to atrophy of the zona compacta of the substantia nigra, but excess iron in the zona reticulata may partially contribute to these findings. MR imaging may be useful for differentiating ''classic'' Parkinson disease from other extrapyramidal degenerative disorders and for predicting response to drug therapy

  12. Early evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Zhou, Nan; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Guo, Tingting; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian

    2016-01-01

    Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and

  13. Rickets on MR images

    Energy Technology Data Exchange (ETDEWEB)

    Ecklund, K.; Jaramillo, D. [Department of Radiology, Children`s Hospital, Boston, MA (United States); Doria, A.S. [Department of Radiology, Instituto da Crianca - Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo (Brazil)

    1999-09-01

    Background. The pathologic changes at the physis in patients with rickets have been well demonstrated histologically. Radiographs can depict only the associated osseous abnormalities. Patients and methods. We report two children in whom MR imaging demonstrated rachitic changes in the physeal cartilage beyond the well-recognized bony features. Results. The striking appearance of the physes and the physes of the secondary ossification centers confirm that MR imaging can successfully evaluate the cartilaginous structures of the developing skeleton. Conclusion. Though MR imaging is clearly unnecessary for the diagnosis of rickets, it is important that the typical features are not misinterpreted as other pathology. (orig.) With 6 figs., 6 refs.

  14. Variable stiffness and damping MR isolator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X Z; Wang, X Y; Li, W H; Kostidis, K [University of Wollongong, School of Mechanical, Materials and Mechatronic Engineering, NSW 2522 (Australia)], E-mail: weihuali@uow.edu.au

    2009-02-01

    This paper presents the development of a magnetorheological (MR) fluid-based variable stiffness and damping isolator for vibration suppressions. The MR fluid isolator used a sole MR control unit to achieve the variable stiffness and damping in stepless and relative large scope. A mathematical model of the isolator was derived, and a prototype of the MR fluid isolator was fabricated and its dynamic behavior was measured in vibration under various applied magnetic fields. The parameters of the model under various magnetic fields were identified and the dynamic performances of isolator were evaluated.

  15. MR imaging of hemimegalencephaly in children

    International Nuclear Information System (INIS)

    Kalifa, G.; Sellier, N.; Demange, P.; Ponsot, G.; Chiron, C.; Robain, O.

    1986-01-01

    Hemimegalencephaly is a rare brain malformation characterized by cerebral asymmetry and cortical dysplasia. Affected infants are seen initially with early seizures and a severe encephalopathy. The author report five new cases studied with MR imaging. MR imaging clearly demonstrated brain hemihypertrophy, abnormal gyration, and poor differentiation between gray and white matter. A highly abnormal disposition of the cellular layers was observed. MR imaging turned out to be the most efficient diagnostic method for hemimegalencephaly. The examination may facilitate understanding and classification of this rare entity. Autopsy findings correlated well with MR imaging appearances

  16. MR appearance of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, F.J.; Leibrock, L.G.; Huseman, C.A.; Makos, M.M.

    1988-02-01

    Hypothalamic hamartoma is the most common detectable cerebral lesion causing precocious puberty. Two histologically confirmed cases were studied by computerized tomography (CT) and magnetic resonance (MR) imaging. T2 weighted, sagittal MR images were superior to CT in delineating the tumor from surrounding grey matter. The lesion was isointense to grey matter on T1 weighted images allowing exclusion of other hypothalamic tumors. MR will undoubtedly become the imaging modality of choice in the detection of hypothalamic hamartoma.

  17. TH-CD-BRA-06: Magnetic Field Effects On Gafchromic-Film Response in MR-IGRT

    International Nuclear Information System (INIS)

    Reynoso, F; Curcuru, A; Green, O; Mutic, S; Santanam, L; Das, I

    2016-01-01

    Purpose: To investigate the effects of magnetic fields in radiochromic films (RCF). Magnetokinetic changes may affect crystal orientation and polymerization within active layer of RCF, these effects are investigated in Magnetic Resonance Image-guided Radiotherapy (MR-IGRT). Methods: Gafchromic EBT2 RCF were irradiated in a 30×30×30 cm 3 solid water phantom using a ViewRay MRIdian Co-60 MRI guided radiotherapy system (B=0.35 T). Fifteen 20.3×25.4 cm 2 EBT2 film sheets were placed at three different depths (d=0.5, 5 and 10 cm) and irradiated using 5 different treatment plans. The plans were computed using the MRIdian treatment planning system to deliver 2, 4, 6, 8, and 10 Gy at a depth of 10 cm. The films were scanned using an Epson Expression 10000 XL flat-bed document scanner in transmission mode. Films were processed before and after irradiation to obtain a net optical density (netOD) for each color channel separately. Scanning electron microscope (SEM) images were obtained to compare the active layer of selected samples. Results: The results show the red channel netOD decreases between 1.3–12.3 % (average of 5.95 %) for doses above 2.8 Gy, with a linear increase in this effect for higher doses. Green channel netOD showed similar results with a decrease between 1.2–10.5 % (average of 4.09 %) for doses above 3.5 Gy. Blue channel showed the weakest effect between 1.3–2.9 % (average of 1.94 %) for doses above 8.0 Gy. SEM images show changes in crystal orientation within active layer in RCF exposed in a magnetic field. Conclusion: The presence of a magnetic field affects crystal orientation and polymerization during irradiation, decreasing netOD by an average of 5.95 % in the red channel. The under response is dependent on dose and differs by up to 12.3 % at 17.6 Gy. The results show that magnetokinetic effects should be carefully considered in MR-IGRT.

  18. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  19. MR imaging of carotid webs

    International Nuclear Information System (INIS)

    Boesen, Mari E.; Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K.; Goyal, Mayank; Frayne, Richard

    2017-01-01

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  20. MR imaging of carotid webs

    Energy Technology Data Exchange (ETDEWEB)

    Boesen, Mari E. [University of Calgary, Department of Biomedical Engineering, Calgary (Canada); Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K. [University of Calgary, Department of Clinical Neurosciences, Calgary (Canada); Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); Goyal, Mayank [Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); University of Calgary, Department of Radiology, Calgary (Canada); Frayne, Richard [Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); University of Calgary, Hotchkiss Brain Institute, Calgary (Canada)

    2017-04-15

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  1. 2011 ESTCP Live Site Demonstrations, Vallejo CA, ESTCP MR-1165, Demonstration Data Report, Former Mare Island Naval Shipyard, MTADS Discrimination Array, (TEMTADS) Survey

    Science.gov (United States)

    2012-04-05

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6110--12-9397 2011 ESTCP Live Site Demonstrations Vallejo , CA ESTCP MR-1165 Demonstration...b. ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT 2011 ESTCP Live Site Demonstrations Vallejo , CA ESTCP MR-1165 Demonstration...Hertz IVS Instrument Verification Strip (f)MINSY (former) Mare Island Naval Shipyard, located in Vallejo , CA MR Munitions Response MTADS Multi-sensor

  2. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  3. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  4. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  5. MR imaging of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Spickler, E.; Lufkin, R.B.; Frazee, J.; Lylyk, P.; Vinuela, F.; Bentson, J.R.; Dion, J.E.

    1987-01-01

    Subarachnoid hemorrhage was produced in four Macaca nemestrina monkeys using the technique of Frazee. CT and MR imaging were performed immediately after the procedure and at frequent intervals up to 2 weeks after hemorrhage. The imaging studies were compared with clinical evaluations and pathologic specimens of all animals. Additional human clinical CT/MR studies of subarachnoid hemorrhage were also studied. Acute hemorrhage was recognized on MR as an increase in signal in the region of clot compared with surrounding cerebrospinal fluid. This most likely reflects T1 shortening due to proton binding rather than a pure paramagnetic effect. While CT is sensitive to the hemoglobin protein in acute hemorrhage, the superior resolution of the basal cisterns on MR images results in equal or better definition of acute subarachnoid hemorrhage on MR in many cases

  6. Fibrolipomatous hamartoma: MR imaging findings

    International Nuclear Information System (INIS)

    De Maeseneer, M.; Jaovisidha, S.; Lenchik, L.; Witte, D.; Schweitzer, M.E.; Sartoris, D.J.; Resnick, D.

    1997-01-01

    Objective. To analyze the MR imaging features of fibrolipomatous hamartoma (FLH) of nerves. Design and patients. MR imaging studies from six patients (three men and three women) were retrospectively reviewed by three musculoskeletal radiologists. In four patients, a biopsy of the nerve lesion was performed. In two patients, biopsy data were unavailable and the diagnosis was based on the clinical history combined with the MR imaging findings. Results and conclusion. MR imaging demonstrated fusiform nerve enlargement that was caused by fatty proliferation and thickening of nerve bundles. Nerve bundles appeared as serpentine tubular structures, hypointense on both T1- and T2-weighted images. The degree of fatty proliferation varied among patients. In addition, significant variation in the distribution of fat along the course of the nerves was noted. In three patients, FLH followed the branching pattern of the nerves, a characteristic pathologic finding. In two patients, intramuscular fat deposition (biceps and tibialis posterior muscles) was present. MR imaging findings of FLH are typical, allowing a confident diagnosis. The variation of fatty proliferation among patients and involved nerves as well as the tendency of the abnormalities to follow the branching pattern of the nerves is well demonstrated with MR imaging. FLH may present as an isolated nerve lesion, may be associated with intramuscular fat deposition, or may occur as a feature of macrodystrophia lipomatosa (MDL). (orig.). With 5 figs., 2 tabs

  7. Meniscal tear. Diagnostic errors in MR imaging

    International Nuclear Information System (INIS)

    Barrera, M. C.; Recondo, J. A.; Gervas, C.; Fernandez, E.; Villanua, J. A.M.; Salvador, E.

    2003-01-01

    To analyze diagnostic discrepancies found between magnetic resonance (MR) and arthroscopy, and the determine the reasons that they occur. Two-hundred and forty-eight MR knee explorations were retrospectively checked. Forty of these showed diagnostic discrepancies between MR and arthroscopy. Two radiologists independently re-analyzed the images from 29 of the 40 studies without knowing which diagnosis had resulted from which of the two techniques. Their interpretations were correlated with the initial MR diagnosis, MR images and arthroscopic results. Initial errors in MR imaging were classified as either unavoidable, interpretive, or secondary to equivocal findings. Eleven MR examinations could not be checked since their corresponding imaging results could not be located. Of 34 errors found in the original diagnoses, 12 (35.5%)were classified as unavoidable, 14 (41.2%) as interpretative and 8 (23.5%) as secondary to equivocal findings. 41.2% of the errors were avoided in the retrospective study probably due to our department having greater experience in interpreting MR images, 25.5% were unavailable even in the retrospective study. A small percentage of diagnostic errors were due to the presence of subtle equivocal findings. (Author) 15 refs

  8. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    Science.gov (United States)

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68 Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68 Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count

  9. Actinomycotic brain infection: registered diffusion, perfusion MR imaging and MR spectroscopy

    International Nuclear Information System (INIS)

    Wang, Sumei; Wolf, Ronald L.; Woo, John H.; Melhem, Elias R.; Poptani, Harish; Wang, Jiongjiong; O'Rourke, Donald M.; Roy, Subhojit

    2006-01-01

    Introduction: Actinomycotic brain infection is caused by an organism of the Actinomyces genus. We report here one such case. Methods: The methods used included coregistered diffusion, perfusion and spectroscopic magnetic resonance (MR) imaging. Decreased apparent diffusion coefficient, markedly elevated fractional anisotropy (FA) and reduced cerebral blood flow were observed. MR spectroscopy demonstrated elevated amino acids, acetate and succinate. Elevated FA values may be due to the microstructure of this special brain infection. (orig.)

  10. Hippocampal MR volumetry

    Science.gov (United States)

    Haller, John W.; Botteron, K.; Brunsden, Barry S.; Sheline, Yvette I.; Walkup, Ronald K.; Black, Kevin J.; Gado, Mokhtar; Vannier, Michael W.

    1994-09-01

    Goal: To estimate hippocampal volumes from in vivo 3D magnetic resonance (MR) brain images and determine inter-rater and intra- rater repeatability. Objective: The precision and repeatability of hippocampal volume estimates using stereologic measurement methods is sought. Design: Five normal control and five schizophrenic subjects were MR scanned using a MPRAGE protocol. Fixed grid stereologic methods were used to estimate hippocampal volumes on a graphics workstation. The images were preprocessed using histogram analysis to standardize 3D MR image scaling from 16 to 8 bits and image volumes were interpolated to 0.5 mm3 isotropic voxels. The following variables were constant for the repeated stereologic measures: grid size, inter-slice distance (1.5 mm), voxel dimensions (0.5 mm3), number of hippocampi measured (10), total number of measurements per rater (40), and number of raters (5). Two grid sizes were tested to determine the coefficient of error associated with the number of sampled 'hits' (approximately 140 and 280) on the hippocampus. Starting slice and grid position were randomly varied to assure unbiased volume estimates. Raters were blind to subject identity, diagnosis, and side of the brain from which the image volumes were extracted and the order of subject presentation was randomized for each of the raters. Inter- and intra-rater intraclass correlation coefficients (ICC) were determined. Results: The data indicate excellent repeatability of fixed grid stereologic hippocampal volume measures when using an inter-slice distance of 1.5 mm and a 6.25 mm2 grid (inter-rater ICCs equals 0.86 - 0.97, intra- rater ICCs equals 0.85 - 0.97). One major advantage of the current study was the use of 3D MR data which significantly improved visualization of hippocampal boundaries by providing the ability to access simultaneous orthogonal views while counting stereological marks within the hippocampus. Conclusion: Stereological estimates of 3D volumes from 2D MR

  11. Applying modern psychometric techniques to melodic discrimination testing: Item response theory, computerised adaptive testing, and automatic item generation.

    Science.gov (United States)

    Harrison, Peter M C; Collins, Tom; Müllensiefen, Daniel

    2017-06-15

    Modern psychometric theory provides many useful tools for ability testing, such as item response theory, computerised adaptive testing, and automatic item generation. However, these techniques have yet to be integrated into mainstream psychological practice. This is unfortunate, because modern psychometric techniques can bring many benefits, including sophisticated reliability measures, improved construct validity, avoidance of exposure effects, and improved efficiency. In the present research we therefore use these techniques to develop a new test of a well-studied psychological capacity: melodic discrimination, the ability to detect differences between melodies. We calibrate and validate this test in a series of studies. Studies 1 and 2 respectively calibrate and validate an initial test version, while Studies 3 and 4 calibrate and validate an updated test version incorporating additional easy items. The results support the new test's viability, with evidence for strong reliability and construct validity. We discuss how these modern psychometric techniques may also be profitably applied to other areas of music psychology and psychological science in general.

  12. MR Spectroscopy and Perfusion MR Imaging Findings of Intracranial Foreign Body Granuloma: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seung Won; Kim, Sang Joon; Kim, Sun Mi; Lee, Jeong Hyun; Choi, Choong Gon; Lee, Deok Hee; Lee, Jung Kyo [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare, Seoul (Korea, Republic of)

    2010-06-15

    We report a case of intracranial foreign body granuloma that showed features of a high grade tumor on magnetic resonance (MR) imaging. However, the relative cerebral blood volume was not increased in the enhancing mass on perfusion MRI and the choline/creatine ratio only slightly increased on MR spectroscopy. The results suggest that the lesion is benign in nature. Perfusion MRI and MR spectroscopy may be helpful to differentiate a foreign body granuloma from a neoplastic condition

  13. Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET

    International Nuclear Information System (INIS)

    Tsoumpas, C.; Mackewn, J.E.; Halsted, P.; King, A.P.; Buerger, C.; Totman, J.J.; Schaeffter, T.; Marsden, P.K.

    2010-01-01

    Positron emission tomography (PET) provides an accurate measurement of radiotracer concentration in vivo, but performance can be limited by subject motion which degrades spatial resolution and quantitative accuracy. This effect may become a limiting factor for PET studies in the body as PET scanner technology improves. In this work, we propose a new approach to address this problem by employing motion information from images measured simultaneously using a magnetic resonance (MR) scanner. The approach is demonstrated using an MR-compatible PET scanner and PET-MR acquisition with a purpose-designed phantom capable of non-rigid deformations. Measured, simultaneously acquired MR data were used to correct for motion in PET, and results were compared with those obtained using motion information from PET images alone. Motion artefacts were significantly reduced and the PET image quality and quantification was significantly improved by the use of MR motion fields, whilst the use of PET-only motion information was less successful. Combined PET-MR acquisitions potentially allow PET motion compensation in whole-body acquisitions without prolonging PET acquisition time or increasing radiation dose. This, to the best of our knowledge, is the first study to demonstrate that simultaneously acquired MR data can be used to estimate and correct for the effects of non-rigid motion in PET. (author)

  14. Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Cristina [University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain); Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain); Imaging Science Institute, Tuebingen (Germany); Bezrukov, Ilja [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany); Schmidt, Holger [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Schwenzer, Nina; Werner, Matthias K. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Kupferschlaeger, Juergen [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Beyer, Thomas [Imaging Science Institute, Tuebingen (Germany); cmi-experts GmbH, Zuerich (Switzerland)

    2012-11-15

    Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem {sup registered} (oral) and Gadovist {sup registered} (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and {sup 18}F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist {sup registered} (IV) and a volunteer study employing two different oral MRCA (Lumirem {sup registered} and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation

  15. Responses of the Human Brain to Mild Dehydration and Rehydration Explored In Vivo by 1H-MR Imaging and Spectroscopy.

    Science.gov (United States)

    Biller, A; Reuter, M; Patenaude, B; Homola, G A; Breuer, F; Bendszus, M; Bartsch, A J

    2015-12-01

    As yet, there are no in vivo data on tissue water changes and associated morphometric changes involved in the osmo-adaptation of normal brains. Our aim was to evaluate osmoadaptive responses of the healthy human brain to osmotic challenges of de- and rehydration by serial measurements of brain volume, tissue fluid, and metabolites. Serial T1-weighted and (1)H-MR spectroscopy data were acquired in 15 healthy individuals at normohydration, on 12 hours of dehydration, and during 1 hour of oral rehydration. Osmotic challenges were monitored by serum measures, including osmolality and hematocrit. MR imaging data were analyzed by using FreeSurfer and LCModel. On dehydration, serum osmolality increased by 0.67% and brain tissue fluid decreased by 1.63%, on average. MR imaging morphometry demonstrated corresponding decreases of cortical thickness and volumes of the whole brain, cortex, white matter, and hypothalamus/thalamus. These changes reversed during rehydration. Continuous fluid ingestion of 1 L of water for 1 hour within the scanner lowered serum osmolality by 0.96% and increased brain tissue fluid by 0.43%, on average. Concomitantly, cortical thickness and volumes of the whole brain, cortex, white matter, and hypothalamus/thalamus increased. Changes in brain tissue fluid were related to volume changes of the whole brain, the white matter, and hypothalamus/thalamus. Only volume changes of the hypothalamus/thalamus significantly correlated with serum osmolality. This is the first study simultaneously evaluating changes in brain tissue fluid, metabolites, volume, and cortical thickness. Our results reflect cellular volume regulatory mechanisms at a macroscopic level and emphasize that it is essential to control for hydration levels in studies on brain morphometry and metabolism in order to avoid confounding the findings. © 2015 by American Journal of Neuroradiology.

  16. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  17. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Zijlstra, Frank; Sikkes, Gonda G.; de Boer, Hans C. J.; Meijer, Gert J.; Kerkmeijer, Linda G. W.; Viergever, Max A.; Lagendijk, Jan J. W.; Seevinck, Peter R.

    2017-10-01

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of 1.1 × 1.1 × 1.2 mm3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a

  18. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy.

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A T; Zijlstra, Frank; Sikkes, Gonda G; de Boer, Hans C J; Meijer, Gert J; Kerkmeijer, Linda G W; Viergever, Max A; Lagendijk, Jan J W; Seevinck, Peter R

    2017-10-03

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of [Formula: see text] mm 3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a

  19. Fast generation of 4D PET-MR data from real dynamic MR acquisitions

    International Nuclear Information System (INIS)

    Tsoumpas, C; Buerger, C; King, A P; Schleyer, P; Schaeffter, T; Marsden, P K; Mollet, P; Keereman, V; Vandenberghe, S; Schulz, V

    2011-01-01

    We have implemented and evaluated a framework for simulating simultaneous dynamic PET-MR data using the anatomic and dynamic information from real MR acquisitions. PET radiotracer distribution is simulated by assigning typical FDG uptake values to segmented MR images with manually inserted additional virtual lesions. PET projection data and images are simulated using analytic forward projections (including attenuation and Poisson statistics) implemented within the image reconstruction package STIR. PET image reconstructions are also performed with STIR. The simulation is validated with numerical simulation based on Monte Carlo (GATE) which uses more accurate physical modelling, but has 150x slower computation time compared to the analytic method for ten respiratory positions and is 7000x slower when performing multiple realizations. Results are validated in terms of region of interest mean values and coefficients of variation for 65 million coincidences including scattered events. Although some discrepancy is observed, agreement between the two different simulation methods is good given the statistical noise in the data. In particular, the percentage difference of the mean values is 3.1% for tissue, 17% for the lungs and 18% for a small lesion. The utility of the procedure is demonstrated by simulating realistic PET-MR datasets from multiple volunteers with different breathing patterns. The usefulness of the toolkit will be shown for performance investigations of the reconstruction, motion correction and attenuation correction algorithms for dynamic PET-MR data.

  20. MR images of oral cancer treated with preoperative radiotherapy

    International Nuclear Information System (INIS)

    Onizawa, Kojiro; Niitsu Mamoru; Yusa, Hiroshi; Yanagawa, Toru; Yoshida, Hiroshi

    2003-01-01

    This study was carried out to evaluate the relationship between the effect of preoperative radiotherapy for oral cancer and the changes of signal intensity with MR images. T2-weighted images were compared before and after radiotherapy in 18 patients with primary oral cancer, and the effect on the lesions was histologically evaluated in surgically resected specimens obtained four weeks after the therapy. The MR images showed significantly decreased signal intensity of the lesions. The decrease of signal intensity was remarkable starting at two weeks after completion of the radiotherapy, compared with the decrease at less than two weeks after the therapy. The change of signal intensity was more obvious in tongue cancer than in other oral cancers. There was no significant difference in the change of the signal intensity between cancers with histologically poor response to the therapy and those with good response. These results suggested that signal intensity of oral cancer on T2-weighted images showed a significant decrease after preoperative radiotherapy, and that the intensity could be affected by duration after radiotherapy and primary sites. (author)

  1. MR of head and neck hemangiomas

    International Nuclear Information System (INIS)

    Bilaniuk, L.T.; Zimmerman, R.A.; Gusnard, D.A.

    1990-01-01

    This paper defines the MR characteristics of head and neck hemangiomas and to evaluate the role of MR in their diagnosis and management. Eighteen pediatric and young adult patients with head and neck hemangiomas (six neck, six face, three eyelid, two scalp, and one parotid) underwent high-field-strength 1.5-T MR imaging. Conventional spin-echo sequences with T1 and T2 weighting were performed. In addition, one-third of patients underwent MR angiography and gadolinium enhancement. The hemangiomas were isointense to muscle on T1-weighted images and hyperintense on proton-density and T2-weighted images

  2. Brain MR imaging in child abuse

    International Nuclear Information System (INIS)

    Sato, Y.; Ellerbroek, C.J.; Alexander, R.; Kao, S.C.S.; Yuh, W.T.C.; Smith, W.L.

    1988-01-01

    Intracranial injuries represent the most severe manifestation of child abuse. CT of the brain is the current standard for evaluation of these infants; however, MR imaging offers several potential advantages. MR imaging and CT were performed in ten infants who suffered intracranial trauma owing to child abuse. CT was slightly better at demonstrating subarachnoid hemorrhage and had definite advantages for defining fractures. MR imaging was superior in the demonstration of subacute extraaxial hemorrhage, deep brain injuries owing to shearing effects from shaking, and anoxic injuries. MR imaging has a definite complementary role in the evaluation of acute intracranial trauma in child abuse victims

  3. CNS involvement in AIDS: spectrum of CT and MR findings

    International Nuclear Information System (INIS)

    Thurnher, M.M.; Thurnher, S.A.; Schindler, E.

    1997-01-01

    The brain may be affected by a variety of abnormalities in association with human immunodeficiency virus (HIV) infection. Knowledge of their existence and characteristic imaging features are important to radiologists for detection, diagnosis, and initiation of an appropriate treatment. Although there is a considerable overlap in the imaging characteristics of different entities, some findings are found to be very suggestive of a particular disease. The CT and MR imaging techniques are commonly used in the diagnosis of neurological disorders in acquired immunodeficiency syndrome (AIDS) patients, to verify treatment response and to guide brain biopsy. This review attempts to describe CT and MR features of infectious and malignant brain disorders in HIV-seropositive patients. (orig.). With 13 figs

  4. MR spectroscopy in metabolic disorders of the brain; MR-Spektroskopie bei Stoffwechselerkrankungen des Gehirns

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2017-06-15

    Metabolic disorders of the brain often present a particular challenge for the neuroradiologist, since the disorders are rare, changes on conventional MR are often non-specific and there are numerous differential diagnoses for the white substance lesions. As a complementary method to conventional brain MRI, MR spectroscopy may help to reduce the scope of the differential diagnosis. Entities with specific MR spectroscopy patterns are Canavan disease, maple syrup urine disease, nonketotic hyperglycinemia and creatine deficiency. (orig.) [German] Die Diagnostik metabolischer Erkrankungen des Gehirns stellt eine besondere Herausforderung in der Neuroradiologie dar, da die Erkrankungen insgesamt selten, die bildmorphologischen Befunde haeufig unspezifisch sind und es eine Vielzahl von Differenzialdiagnosen fuer die Veraenderungen der weissen Substanz gibt. Als zusaetzliche Technik kann die MR-Spektroskopie bei Stoffwechselerkrankungen helfen, die Diagnose einzugrenzen. Krankheitsentitaeten, die spezifische Veraenderungen in der Spektroskopie aufweisen, sind der Morbus Canavan, die Ahornsirupkrankheit, die nichtketotische Hyperglyzinaemie und Kreatinmangelsyndrome. (orig.)

  5. MR imaging evaluation of diabetic foot

    International Nuclear Information System (INIS)

    Beltran, J.; Campanini, D.S.; McCalla, M.; Knight, C.T.

    1988-01-01

    Fourteen diabetic patients with suspected foot infection and/or neuropathic joint were evaluated with MR imaging to identify the presence and extent of infection and also to exclude coexistent infection in the neuropathic joint. Osteomyelitis (n = 8), abscess (n = 7), septic arthritis (n = 4), tenosynovitis (n = 4), and neuropathic joint (n = 5) were diagnosed with MR imaging. Osteomyelitis and/or abscess were excluded by MR findings in 13 instances. Most patients with infection had one more than one site of involvement. Clinical or surgical confirmation of the MR diagnoses was obtained in all but nine of the infection sites or cases of neuropathic joint. Only one false-negative diagnosis of osteomyelitis was made in this series. It is concluded that MR imaging provided accurate information regarding the presence and extent of infection and that this information was decisive in patient management

  6. MR diagnosis of dural sinus thrombosis

    International Nuclear Information System (INIS)

    Rovira Canellas, A.; Turon Estrada, A.; Alvarez Sabin, J.; Lozano Sanchez, M.; Castano Duque, Ch.; Grive Isern, E.; Sumalla Sune, J.

    1994-01-01

    Four adult patients were diagnosed as having dural sinus thrombosis (DST) by means of magnetic resonance (MR). In the three cases of acute thrombosis, MR disclosed diffuse or segmental hyperintensity in the sinuses involved, which persisted regardless of the sequence and orientation of the plane selected. MR angiography (MRA) provided diagnostic information that proved useful in the chronic case, as well as in the two cases in which follow-up was carried out to determine the degree to which permeability was restored to the sinuses involved. MR diagnosis of DST can produce false positives and negatives, the causes of which should be known, as well as the ways to avoid them, in order to prevent diagnostic errors. MR, when applied and interpreted correctly, can be considered the first, and in many cases the only, choice as a diagnostic method in DST. (Author)

  7. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    Science.gov (United States)

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  8. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  9. MR implant labelling and its use in clinical MRI practice; MR-Implantatkennzeichnungen und ihre Anwendung in der klinischen MRT-Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany)

    2015-08-15

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [German] Implantate in Patienten muessen vor einer MR-Untersuchung auf MR-Sicherheit abgeklaert werden, um moegliche z. T. schwere Verletzungen und Implantatfehlfunktionen in einer MR-Umgebung weitestgehend auszuschliessen. Es gilt unveraendert die generelle Kontraindikation von

  10. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  11. CT and MR imaging of the kidney and adrenal glands: MR imaging of the kidney and adrenal glands

    International Nuclear Information System (INIS)

    Lee, J.K.T.

    1987-01-01

    The normal anatomy of the kidney is clearly demonstrated with MR imaging. The renal cortex can be differentiated from the renal medulla; renal vessels can also be identified. MR imaging can differentiate cystic from solid lesions. The signal intensity of a renal cell carcinoma varies and overlaps with the signal intensities of renal neoplasms of other etiologies. MR imaging is superior to CT in distinguishing vascular from nonvascular structures. It can distinguish collateral vessels from lymph nodes and can disclose tumoral thrombi. MR imaging can also aid in the differentiation of acute rejection from acute tubular necrosis in renal transplant recipients. Both normal and abnormal adrenal glands can be seen on MR imaging. A normal adrenal gland has a signal intensity higher than or equal to that of muscle but lower than that of fat. T1-weighted images offer excellent antomic resolution; T2-weighted images provide additional information about internal characteristics of adrenal neoplasms. Preliminary data indicate that MR imaging is useful in distinguishing nonfunctioning adenomas from adrenal metastases. The role of MR imaging of the kidney and adrenal gland is discussed

  12. Normal anatomy of the fetus at MR imaging.

    Science.gov (United States)

    Amin, R S; Nikolaidis, P; Kawashima, A; Kramer, L A; Ernst, R D

    1999-10-01

    Owing to recent advances in magnetic resonance (MR) imaging, the role of obstetric MR imaging has increased in cases in which the results of ultrasonography are equivocal. Fast MR imaging sequences, such as T2-weighted fast spin-echo (SE), half-Fourier single-shot fast SE, 0.5-signal-acquired single-shot fast SE, and echo-planar imaging, have virtually eliminated the need for fetal premedication, with a concomitant improvement in image resolution and diminished blurring. Artifacts related to maternal respiratory motion and fetal motion no longer limit the anatomic detail that can be demonstrated with MR imaging. With such advances in obstetric MR imaging, knowledge of normal fetal anatomy at MR imaging is essential to detect disease in utero. MR imaging can demonstrate fetal anatomy in detail, especially the brain, thorax, abdomen, pelvis, and vasculature. Major developmental structures of the fetus, particularly the cranial nervous system, naso- and oropharynx, lungs, and major abdominal viscera, can be adequately evaluated with targeted fast MR imaging as early as the beginning of the second trimester. However, MR imaging of the heart remains limited. Fetal MR imaging during the first trimester remains controversial secondary to biosafety issues and is limited due to diminutive fetal size.

  13. MR imaging of acute cervical spine injuries

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyu Hwa; Lee, Jung Hyung; Joo, Yang Goo [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1995-01-15

    To describe magnetic resonance (MR) findings of the patients with acute cervical spinal injury and to assess the usefulness of the MR imagings. We retrospectively reviewed the MR images of 32 patients with acute cervical spinal injury. MR images were obtained with a 2.0 T superconductive MR imaging units (Spectro-20000, Gold-Star, Seoul), using spin-echo and gradient-echo technique. Most of patients were in their 3rd-4th decades and motor vehicle accident was the most frequent cause of acute cervical trauma. We assessed the MR findings with respect to the spinal cord, ligaments, paravertebral soft tissues, intervertebral disk, and bony spine. Spinal cord injury was the most common (65%), where cord swelling, edema, and/or hematoma were demonstrated most frequently at C5-6 level. Traumatic intervertebral disk herniations were the second most common (62.5%) and frequently occurred at the lower cervical levels, mostly at C5-6. Paravertebral soft tissue injury, vertebral body fracture, bone marrow edema and displacement were also well shown on MR images. MR imaging appears to be essential for the evaluation of traumatic disk herniations, spinal cord abnormalities, and injury of paravertebral soft tissue in the acute injury of the cervical spine.

  14. MR imaging of acute cervical spine injuries

    International Nuclear Information System (INIS)

    Kim, Kyu Hwa; Lee, Jung Hyung; Joo, Yang Goo

    1995-01-01

    To describe magnetic resonance (MR) findings of the patients with acute cervical spinal injury and to assess the usefulness of the MR imagings. We retrospectively reviewed the MR images of 32 patients with acute cervical spinal injury. MR images were obtained with a 2.0 T superconductive MR imaging units (Spectro-20000, Gold-Star, Seoul), using spin-echo and gradient-echo technique. Most of patients were in their 3rd-4th decades and motor vehicle accident was the most frequent cause of acute cervical trauma. We assessed the MR findings with respect to the spinal cord, ligaments, paravertebral soft tissues, intervertebral disk, and bony spine. Spinal cord injury was the most common (65%), where cord swelling, edema, and/or hematoma were demonstrated most frequently at C5-6 level. Traumatic intervertebral disk herniations were the second most common (62.5%) and frequently occurred at the lower cervical levels, mostly at C5-6. Paravertebral soft tissue injury, vertebral body fracture, bone marrow edema and displacement were also well shown on MR images. MR imaging appears to be essential for the evaluation of traumatic disk herniations, spinal cord abnormalities, and injury of paravertebral soft tissue in the acute injury of the cervical spine

  15. Introduction of a MR-compatible system for extracorporal perfusion of vital organs for MR-guided procedures. First-experiences

    International Nuclear Information System (INIS)

    Gaffke, Gunnar; Nagel, Stefan; Hegemann, Olaf; Speck, Ulrich; Grosse-Siestrup, Christian; Jungnickel, Kerstin; Stroszczynski, Christian

    2009-01-01

    Purpose:To represent a MRI-compatible perfusion-system for extracorporeal perfusion of vital organs which permits the realisation of realistic experiments in a MR scanner. Material and methods: We performed MR examinations of explanted porcine livers and MR-guided interventions in porcine livers. Explanted organs were hemo-perfused under physiological conditions during the experiments. MR-sequences for diagnostic and interventional examinations were used. Results:The evaluated system was MRI-compatible. The achieved image quality of the used sequences showed excellent anatomical resolution. Planned experiments can be carried out with relatively low expenditure. Diagnostic as well as interventional investigations can be carried out. The used organs showed a stable function within physiological parameters up to 4 hours. Conclusion:It is possible to perform ex vivo experiments under in vivo conditions with this system. With the used MR-compatible system MR-guided experimental interventions and thermal ablations can be carried out in explanted organs under in vivo conditions. (orig.)

  16. Deep MR to CT synthesis using unpaired data

    NARCIS (Netherlands)

    Wolterink, Jelmer M.; Dinkla, Anna M.; Savenije, Mark H.F.; Seevinck, Peter R.; van den Berg, Cornelis A.T.; Išgum, Ivana

    2017-01-01

    MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between paired images could lead to errors in synthesized CT images. To

  17. Serial MR imaging in Creutzfeldt-Jakob disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, A.; Hata, H.; Ohno, M. (Kyushu Rosai Hospital, Kitakyushu (Japan). Dept. of Radiology); Yoshinaga, M.; Shiokawa, O. (Kyushu Rosai Hospital, Kitakyushu (Japan). Stroke Care Unit)

    1991-08-01

    Serial magnetic resonance (MR) imagings of two autopsied patients with Creutzfeldt-Jakob disease (CJD) are presented. Both patients showed a dramatic progression of brain atrophy. The initial MR imagings were, however, interpreted as normal except for localized mild cortical atrophy in one patient. When a normal MR image is obtained in a demented middle-aged or aged patient, CJD may still need to be ruled out: follow up MR imaging may be useful. (orig.).

  18. Serial MR imaging in Creutzfeldt-Jakob disease

    International Nuclear Information System (INIS)

    Uchino, A.; Hata, H.; Ohno, M.; Yoshinaga, M.; Shiokawa, O.

    1991-01-01

    Serial magnetic resonance (MR) imagings of two autopsied patients with Creutzfeldt-Jakob disease (CJD) are presented. Both patients showed a dramatic progression of brain atrophy. The initial MR imagings were, however, interpreted as normal except for localized mild cortical atrophy in one patient. When a normal MR image is obtained in a demented middle-aged or aged patient, CJD may still need to be ruled out: follow up MR imaging may be useful. (orig.)

  19. MR findings of brainstem injury

    Energy Technology Data Exchange (ETDEWEB)

    Park, Man Soo; Hwang, Woo Cheol; Park, Choong Ki [Hallym University College of Medicine, Seoul (Korea, Republic of); Suh, Dae Chul [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Sang Joon [Dankook University of College of Medicine, Cheonan (Korea, Republic of)

    1995-02-15

    To analyze the characteristics of traumatic brainstem injury by CT and MR. CT and MR studies of 10 patients with traumatic brainstem lesion in MR were retrospectively reviewed, particularly attended to location, signal intensity and associated lesions. CT failed to depict 8 of 10 brainstem lesions. All lesions were detected in MR images with T2-weighted images showing higher detection rate (n = 10) (100%) than T1-weighted images (n = 3) (30%) or CT (n = 2) (20%). The brainstem lesions located in the dorsolateral aspects of the rostral brainstem (mid brain and upper pons) in 7 (70%) cases, in ventral aspects of rostral brain in 2 (20%) cases and in median portion of pons in 1 (10%) case. Corpus callosal (n = 5), lobar white matter (n = 5) diffuse axonal injury, and 2 hemorrhagic lesions in basal ganglia were the associated findings. MR imaging is more helpful than CT in the detection of brainstem injury, especially T2 weighted images. Primary brainstem lesions were typically located in the dorsolateral aspect of rostral brainstem (midbrain and upper pons). Corpus callosum and white matter lesions were frequently associated.

  20. MR evaluation of fetal demise

    International Nuclear Information System (INIS)

    Victoria, Teresa; Chauvin, Nancy Anne; Johnson, Ann M.; Kramer, Sandra Sue; Epelman, Monica; Capilla, Elena

    2011-01-01

    Fetal demise is an uncommon event encountered at MR imaging. When it occurs, recognition by the interpreting radiologist is important to initiate appropriate patient management. To identify MR findings of fetal demise. Following IRB approval, a retrospective search of the radiology fetal MR database was conducted searching the words ''fetal demise'' and ''fetal death.'' Fetuses with obvious maceration or no sonographic confirmation of death were excluded. Eleven cases formed the study group. These were matched randomly to live fetuses of similar gestational age. Images were reviewed independently by three pediatric radiologists. The deceased fetus demonstrates decreased MR soft-tissue contrast and definition of tissue planes, including loss of gray-white matter differentiation in the brain. The signal within the cardiac chambers, when visible, is bright on HASTE sequences from the stagnant blood; the heart is small. Pleural effusions and decreased lung volumes may be seen. Interestingly, the fetal orbits lose their anatomical round shape and become smaller and more elliptical; a dark, irregular rim resembling a mask may be seen. Although fetal demise is uncommonly encountered at MR imaging, radiologists should be aware of such imaging findings so prompt management can be instituted. (orig.)

  1. A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI.

    Science.gov (United States)

    Bohning, Daryl E; Denslow, S; Bohning, P A; Walker, J A; George, M S

    2003-11-01

    Transcranial magnetic stimulation (TMS) can be interleaved with fMRI to visualize regional brain activity in response to direct, non-invasive, cortical stimulation, making it a promising tool for studying brain function. A major practical difficulty is accurately positioning the TMS coil within the MRI scanner for stimulating a particular area of brain cortex. The objective of this work was to design and build a self-contained hardware/software system for MR-guided TMS coil positioning in interleaved TMS/fMRI studies. A compact, manually operated, articulated TMS coil positioner/holder with 6 calibrated degrees of freedom was developed for use inside a cylindrical RF head coil, along with a software package for transforming between MR image coordinates, MR scanner space coordinates, and positioner/holder settings. Phantom calibration studies gave an accuracy for positioning within setups of dx=+/-1.9 mm, dy=+/-1.4 mm, dz=+/-0.8 mm and a precision for multiple setups of dx=+/-0.8 mm, dy=+/-0.1 mm, dz=+/-0.1 mm. This self-contained, integrated MR-guided TMS system for interleaved TMS/fMRI studies provides fast, accurate location of motor cortex stimulation sites traditionally located functionally, and a means of consistent, anatomy-based TMS coil positioning for stimulation of brain areas without overt response.

  2. Unusual MR manifestations of neurocysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Suh, D.C. (Seoul National Univ. (Republic of Korea). Dept. of Radiology; Woolsan Medical Coll., Seoul (Republic of Korea). Dept. of Radiology); Chang, K.H.; Han, M.H.; Han, M.C.; Kim, C.W. (Seoul National Univ. (Republic of Korea). Dept. of Radiology); Lee, S.R. (Hanyang Univ., Seoul (Republic of Korea). Dept. of Radiology)

    1989-11-01

    MR and CT features of neurocysticercosis are variable and depend fundamentally on the stage in evolution of the infection, location, number and size of the worm. The authors retrospectively evaluated MR images obtained on a 2.0T superconducting unit in 22 neurocysticercosis patients and observed various MR features including some new findings. A variety of MR findings are presented with special reference to six case reports. The features include: (1) A large simple cyst containing both internal septations and a scolex; (2) suprasellar racemose cysts mimicking other cysts, (3) a fourth ventricular cyst readily depicted by aid of CSF flow-void in the sagittal plane; (4) degenerating cysts showing 'white target' appearance; (5) granulomatous lesions having a 'black target' appearance; and (6) a meningitic form showing Gd-DTPA enhancement of basal cisterns and of a subacute infarct. (orig.).

  3. Reproducibility of MR-based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer

    DEFF Research Database (Denmark)

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H

    2018-01-01

    AIM: Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) is dependent upon reliable and reproducible MR-based attenuation correction (MR-AC). In this study we evaluated the quality of current vendor-provided thoracic MR-AC maps, and further investigated...... affecting the reproducibility of PET/MRI. This, in combination with other well-known sources of error associated with PET/MRI examinations, leads to inconsistent SUV measurements in serial studies and follow-up scenarios, which may affect the reliability of therapy response assessment. A thorough visual...

  4. Functional magnetic resonance imaging (fMRI) for fetal oxygenation during maternal hypoxia: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Adam, G. [Abt. fuer Diagnostische und Interventionelle Radiologie, Klinik und Poliklinik fuer Radiologie, UKE Hamburg (Germany); Tchirikov, M.; Schroeder, H. [Abt. fuer experimentelle Gynaekologie der Universitaetsfrauenklinik, Klinik und Poliklinik fuer Frauenheilkunde, UKE, Hamburg (Germany); Koch, M. [Klinik und Poliklinik fuer Neurologie, UKE Hamburg (Germany)

    2002-06-01

    Hirn ({proportional_to}10%). Schlussfolgerungen: Die funktionelle MR-Bildgebung ist ein vielversprechendes Verfahren zur Darstellung des fetalen Gewebssauerstoffgehaltes und ermoeglicht eventuell neue Verfahren in der Betreuung von Risikoschwangerschaften. Die unterschiedlich starken Signalabfaelle in Leber/Myokard und Gehirn spiegeln vermutlich die Zentralisation des fetalen Kreislaufes wider. (orig.)

  5. MR staging of malignant musculoskeletal tumors: An experimental study on MR and pathologic correlation of rabbit VX-2 carcinoma

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Chung, Sung Hoon; KIm, Cheol Woo; Kim, Seong Moon; Im, Jung Gi; Han, Man Chung

    1993-01-01

    To evaluate the reliability of MR imaging in tissue characterization and depiction of tumor boundaries, we performed MR pathologic correlation using parosteally implanted VX-2 carcinoma in 17 rabbit thighs. T1-weighted, T2-weighted and Gd-DTPA enhanced T1-weighted axial images were obtained 10-30 days after tumor implantation. After the animals were killed, frozen and sectioned along the MR imaging planes, and histopathologic examination were done. For accurate MR pathologic correlation, rabbit were fixed on the cardboard plate to minimize position change during the procedure. Tumor boundaries depicted on MR images were larger than those depicted on the specimen. Small tumors were surrounded by capsule-like loose connective tissue. Loose connective tissue became compact with tumor growth. This connective tissue showed high signal intensity on both T2-weighted and Gd-DTPA enhanced T1-weighted images. Muscle atrophy with fatty tissue accumulation around the tumor also contributed to the high signal intensity on MR images. Peritumoral edema and inflammatory reaction were not remarkable. Six of 8 cases with bone marrow fibrosis were detected on MR images. We concluded that peritumoral loose connective tissue and muscle atrophy exaggerated the size of experimentally induced malignant musculoskeletal tumors on MR images

  6. Craniofacial duplication (diprosopus): CT, MR imaging, and MR angiography findings case report.

    Science.gov (United States)

    Hähnel, Stefan; Schramm, Peter; Hassfeld, Stefan; Steiner, Hans H; Seitz, Angelika

    2003-01-01

    Diprosopus is one of the rarest malformations in humans. In addition to the facial structures, the cerebral frontal lobes were duplicated in this case. Three pairs of anterior cerebral arteries were detected, and the rostral parts of the superior sagittal sinus were duplicated. Computed tomography, magnetic resonance (MR) imaging, and MR angiography allowed study of the degree of duplicative changes in diprosopus, especially for planning cosmetic correction. Copyright RSNA, 2002

  7. Breast MR imaging: correlation of high resolution dynamic MR findings with prognostic factors

    International Nuclear Information System (INIS)

    Lee, Shin Ho; Cho, Nariya; Chung, Hye Kyung; Kim, Seung Ja; Cho, Kyung Soo; Moon, Woo Kyung; Cho, Joo Hee

    2005-01-01

    We wanted to correlate the kinetic and morphologic MR findings of invasive breast cancer with the classical and molecular prognostic factors. Eighty-seven patients with invasive ductal carcinoma NOS underwent dynamic MR imaging at 1.5 T, and with using the T1-weighted 3D FLASH technique. The morphologic findings (shape, margin, internal enhancement of the mass or the enhancement distribution and the internal enhancement of any non-mass lesion) and the kinetic findings (the initial phase and the delayed phase of the time-signal. Intensity curve) were interpreted using a ACR BI-RADS-MRI lexicon. We correlate MR findings with histopathologic prognostic factors (tumor size, lymph node status and tumor grade) and the immunohistochemically detected biomarkers (ER, PR, ρ 53, c-erbB-2, EGFR and Ki-67). Univariate and multivariate statistical analyses were than performed. Among the MR findings, a spiculated margin, rim enhancement and washout were significantly correlated with the prognostic factors. A spiculated margin was independently associated with the established predictors of a good prognosis (a lower histologic and nuclear grade, positive ER and PR) and rim enhancement was associated with a poor prognosis (a higher histologic and nuclear grade, negative ER and PR). Wash out was a independent predictor of Ki-67 activity. Some of the findings of high resolution dynamic MR imaging were associated with the prognostic factors, and these findings may predict the prognosis of breast cancer

  8. MR imaging of the spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Duthoy, M.J.; Lund, G.

    1988-08-01

    MR imaging was reviewed in 66 pediatric spinal cord patients with diagnoses of posterior fossa tumor, primary spinal cord tumor, metastatic disease, neuroectodermal disorder, congenital malformation, trauma, and demyelinating, neurodegenerative, or metabolic disorders. MR proved to be useful in delineating the extent of posterior fossa and cord tumor including metastasis to the cord. MR was of limited value in demyelinating and metabolic disorders. Arnold Chiari malformations, syringomyelia, tethered cord and meningoceles were all easily evaluated using MR.

  9. Value of new MR techniques in MR-PET

    International Nuclear Information System (INIS)

    Attenberger, U.I.; Schoenberg, S.O.; Quick, H.H.; Guimaraes, A.; Catalano, O.; Morelli, J.N.

    2013-01-01

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [de

  10. Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

    International Nuclear Information System (INIS)

    Blumhagen, Jan O.; Ladebeck, Ralf; Fenchel, Matthias; Braun, Harald; Quick, Harald H.; Faul, David; Scheffler, Klaus

    2014-01-01

    Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B 0 ) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B 0 inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the

  11. Transcriptome and metabolome responses of Shewanella oneidensis MR-1 to methyl orange under microaerophilic and aerobic conditions.

    Science.gov (United States)

    Cao, Xinhua; Qi, Yueling; Xu, Chen; Yang, Yuyi; Wang, Jun

    2017-04-01

    Shewanella oneidensis MR-1 degrades various azo dyes under microaerophilic and anaerobic conditions, but this process is inhibited under aerobic conditions. The mechanisms underlying azo dye biodegradation and inhibition remain unknown. Therefore, we investigated metabolic and transcriptional changes in strain MR-1, which was cultured under different conditions, to elucidate these mechanisms. At the transcriptional level, genes involved in certain metabolic processes, particularly the tricarboxylic acid (TCA) cycle, amino acid biodegradation, and the electron transfer system, were significantly altered (M ≧ 2, p > 0.8 ) in the presence of methyl orange (MO). Moreover, a high concentration of dissolved oxygen heavily impacted the expression levels of genes involved in fatty acid biodegradation. Metabolome analysis revealed significant alteration (p < 0.05) in the concentrations of nine metabolites when strain MR-1 was cultured under aerobic conditions; the majority of these metabolites were closely associated with amino acid metabolism and DNA replication. Accordingly, we propose a possible pathway for MO biodegradation and discuss the most likely causes of biodegradation inhibition due to dissolved oxygen.

  12. MR evaluation of brachial plexus injuries

    International Nuclear Information System (INIS)

    Gupta, R.K.; Jain, R.K.; Mehta, V.S.; Banerji, A.K.

    1989-01-01

    Ten cases of brachial plexus injury were subjected to magnetic resonance (MR) to demonstrate the roots, trunks, divisions or cord abnormalities. Both normal and abnormal brachial plexuses were imaged in sagittal, axial, coronal and axial oblique planes. Myelography, using water soluble contrast agents, was performed in seven cases. MR demonstrated one traumatic meningocele, one extradural cerebrospinal fluid (CSF) collection, trunk and/or root neuromas in four, focal root fibrosis in two and diffuse fibrosis in the remaining two cases. Results of MR were confirmed at surgery in four cases with neuromas, while myelography was normal in two and was not carried out in the remaining two. In two cases, where MR demonstrated diffuse fibrosis of the brachial plexus, myelography showed C7 and T1 traumatic meningocele in one and was normal in the other. Both these patients showed excellent clinical and electrophysiological correlation with MR findings and in one of them surgical confirmation was also obtained. In the other two cases with focal nerve root fibrosis, myelography was normal in one and showed a traumatic meningocele in another. Operative findings in these cases confirmed focal root fibrosis but no root avulsion was observed although seen on one myelogram. Focal fibrosis, however, was noted at operation in more roots than was observed with MR. Initial experience suggests that MR may be the diagnostic procedure of choice for complete evaluation of brachial plexus injuries. (orig.)

  13. MR imaging of von Hippel-Lindau disease

    International Nuclear Information System (INIS)

    Sato, Y.; Waziri, M.H.; Smith, W.L.; Frey, E.E.; Franken, E.A.

    1986-01-01

    Sixteen patients with von Hippel-Lindau disease (VH-L) and 11 asymptomatic family members underwent a total of 29 central nervous system (CNS) and 23 body MR imaging evaluations during a 2-year study period. Nineteen CNS and spinal lesions and nine abdominal visceral lesions were identified on MR imaging and were confirmed at surgery or by other imaging modalities. MR imaging is superior to CT in the evaluation of intraocular vitreous abnormalities and cerebellar and spinal hemangioblastomas because of superior tissue characterization and lack of bone artifacts. MR imaging adequately demonstrated the abdominal visceral lesions. MR imaging is a sensitive and reliable imaging modality for the various lesions of VH-L

  14. Practical Considerations for Clinical PET/MR Imaging.

    Science.gov (United States)

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. MR imaging of pleural and peritoneal effusion

    International Nuclear Information System (INIS)

    Shiono, Takahiro; Yoshikawa, Kohki; Takenaka, Eiichi; Hisamatsu, Katsuji

    1993-01-01

    The purpose of this study was to assess the efficacy of MR imaging in predicting the quality of ascites and pleural effusion. MR examinations of 20 patients with different benign or malignant diseases accompanied with ascites or pleural effusion were retrospectively studied. Results were compared with histopathological findings. On T 1 - and T 2 -weighted images, the MR intensity of the effusion depended mainly on the concentration of protein, whereas on gradient echo images, it depended mainly on the concentration of blood. MR examination was useful in non-invasively differentiating exudative or hemorrhagic effusion from serous effusion. Knowledge or inference of the quality of effusion can direct MR interpretation and may improve diagnostic accuracy. (author)

  16. MR imaging-guided percutaneous cryotherapy for lung tumors: initial experience.

    Science.gov (United States)

    Liu, Shangang; Ren, Ruimei; Liu, Ming; Lv, Yubo; Li, Bin; Li, Chengli

    2014-09-01

    To evaluate prospectively the initial clinical experience of magnetic resonance (MR) imaging-guided percutaneous cryotherapy of lung tumors. MR imaging-guided percutaneous cryotherapy was performed in 21 patients with biopsy-proven lung tumors (12 men, 9 women; age range, 39-79 y). Follow-up consisted of contrast-enhanced chest computed tomography (CT) scan performed at 3-month intervals to assess tumor control; CT scanning was carried out for 12 months or until death. Cryotherapy procedures were successfully completed in all 21 patients. Pneumothorax occurred in 7 (33.3%) of 21 patients. Chest tube placement was required in one (4.8%) case. Hemoptysis was exhibited by 11 (52.4%) patients, and pleural effusion occurred in 6 (28.6%) patients. Other complications were observed in 14 (66.7%) patients. The mean follow-up period was 10.5 months (range, 9-12 mo) in patients who died. At month 12 of follow-up, 7 (33.3%) patients had a complete response to therapy, and 10 (47.6%) patients showed a partial response. In addition, two patients had stable disease, and two patients developed progressive disease; one patient developed a tumor in the liver, and the other developed a tumor in the brain. The 1-year local control rate was 81%, and 1-year survival rate was 90.5%. MR imaging-guided percutaneous cryotherapy appears feasible, effective, and minimally invasive for lung tumors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  17. Changes of renal blood flow after ESWL: Assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index

    Energy Technology Data Exchange (ETDEWEB)

    Abd Ellah, Mohamed, E-mail: dr_m_hamdy2006@hotmail.co [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Kremser, Christian, E-mail: christian.kremser@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pallwein, Leo, E-mail: leo.pallwein-prettner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Aigner, Friedrich, E-mail: friedrich.Aigner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Schocke, Michael, E-mail: michael.schocke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Peschel, Reinhard, E-mail: reinhard.peschel@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pedross, Florian, E-mail: florian.pedross@i-med.ac.a [Innsbruck Medical University, Medical Statistics Dept., Anich St. 35, 6020 Innsbruck (Austria); Pinggera, Germar-Michael, E-mail: germar.pinggera@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Wolf, Christian, E-mail: christian.wolf@bkh-reutte.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Alsharkawy, Mostafa A.M., E-mail: drmostafamri@yahoo.co [Assiut University, Radiology Dept., Assiut (Egypt); Jaschke, Werner, E-mail: werner.jaschke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Frauscher, Ferdinand, E-mail: ferdinand.frauscher@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria)

    2010-10-15

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12 h before and 12 h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (p < 0.001) was found in both treated and untreated kidneys. ASL MR imaging also showed significant changes in both kidneys (p < 0.001). Contrast enhanced dynamic MR imaging did not show significant changes in the kidneys. ESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow.

  18. MR imaging of the neonatal brain: Pathologic features

    International Nuclear Information System (INIS)

    McArdle, C.B.; Richardson, C.J.; Nicholas, D.A.; Hayden, C.K.; Amparo, E.G.

    1986-01-01

    Seventy-three neonates, aged 29-43 weeks since conception, were studied. US and/or CT correlations were obtained in most infants with pathology. In the first 4-5 days after hemorrhage, US and CT were superior to MR imaging, but after that time MR imaging was the single best modality for imaging blood. In early premature infants with very watery white matter, US detected infarction and brain edema that were poorly seen on both MR imaging and CT. However, in late premature and full-term infants, MR imaging was better than CT in distinguishing between normal white matter and infarction. Only MR imaging disclosed delayed myelination in 13 term infants with hydrocephalus and severe asphyxia. MR imaging with play an important role in imaging neonates once MR imaging-compatible monitors and neonatal head coils become widely available

  19. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  20. Dynamic MR-mammography in invasive lobular breast cancer; Dynamische MR-Mammographie beim invasiv lobulaeren Mammakarzinom bei 1,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sittek, H.; Perlet, C.; Kessler, M.; Reiser, M. [Institut fuer Radiologische Diagnostik, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany); Untch, M. [Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany)

    1998-12-31

    Material and Methods: We carried out 1505 MR mammographoes in 1357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement, and type 3 with diffuse contrast enhancement of the glandular body. Results: Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. (orig.) [Deutsch] Material und Methode: Im Zeitraum 05/1993 bis 06/1996 fuehrten wir bei 1357 Patientinnen 1505 MR-Mammographien durch. In 413 Faellen wurde eine Probeexzision indiziert. Die histologische Untersuchung ergab in 214 Faellen einen malignen Tumor. Darunter befanden sich 23 ILC. Die MR-M wurden an einem 1,0 T MRT-System (Impact, Siemens, Erlangen) mit einer dynamischen FLASH 3D Sequenz durchgefuehrt. Neben dem prozentualen Anstieg der Signalintensitaet innerhalb einer Laesion haben wir fuer die Diagnostik folgende morphologische Befundmuster (BM) unterschieden: Typ 1: Keine Aufnahme, Typ 2: Fokale Aufnahme, Typ 3: Diffuse Aufnahme des Druesenkoerpers in der MR-M. Ergebnisse: Mit der MR-M konnten 19/23 (82,6%) der ILC anhand einer fokalen Zunahme der Signalintensitaet richtig positiv erkannt werden (BM Typ 2). Vier der ILC waren in der MR-M falsch negativ. In zwei Faellen (2/23) war keine Zunahme der Signalintensitaet zu verzeichnen (BM Typ 1). In zwei weiteren Faellen (2/23) maskierte eine diffuse Signalintensitaetszunahme des Druesenkoerpers (BM Typ 3

  1. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Paetzel, C.; Zorger, N.; Bachthaler, M.; Voelk, M.; Seitz, J.; Herold, T.; Feuerbach, S.; Lenhart, M.; Nitz, W.R.

    2004-01-01

    Purpose: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. Materials and Methods: Three patients (1 female, 2 male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n=2) or popliteal (n=1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71-88%. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035'' guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. Results: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed

  2. Brain MR imaging in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Ae; Chang, Kee Hyun; Han, Moon Hee; Lee, Kyung Hwon; Kim, Sung Kwon; Lee, Jung Sang [Seoul National University College of Medicine, Seoul (Korea, Republic of); Cha, Sang Hoon [Chungbuk National University College of Medicine, Chungju (Korea, Republic of)

    1992-09-15

    To present MR imaging findings of intracranial lesions in systemic lupus erythematosus(SLE), a retrospective study was performed on MR images of 33 SLE patients with neurologic symptoms and signs. MR imaging was performed on either a 0.5 T (21 patients) or 2.0 T unit (12 patients), using T1-weighted, proton-density-weighted, and T2-weighted spin echo sequences in all patients. In seven patients, post-contrast T1-weighted images were also obtained after administration of gadopentetate dimeglumine. The main MR findings consisted of focal lesions suggesting ischemia/infarct (15 patients), diffuse brain atrophy (8), and findings associated with infection (4). The MR findings were normal in 11 patients (33%). The focal lesions suggesting ischemia/infarcts presumably secondary to vasculitis were distributed in the cortex or subcortical white matter (7 patients), deep periventricular white matter (3), or in both areas (5). Most of the focal lesions were multiple and small in size. The findings associated with infection were variable and included communicating hydrocephalus, meningeal enhancement, granuloma, etc. MR findings of SLE were non-specific and therefore clinical correlation is needed when evaluating SLE in MR.

  3. Rosen's (M,R) system in process algebra.

    Science.gov (United States)

    Gatherer, Derek; Galpin, Vashti

    2013-11-17

    Robert Rosen's Metabolism-Replacement, or (M,R), system can be represented as a compact network structure with a single source and three products derived from that source in three consecutive reactions. (M,R) has been claimed to be non-reducible to its components and algorithmically non-computable, in the sense of not being evaluable as a function by a Turing machine. If (M,R)-like structures are present in real biological networks, this suggests that many biological networks will be non-computable, with implications for those branches of systems biology that rely on in silico modelling for predictive purposes. We instantiate (M,R) using the process algebra Bio-PEPA, and discuss the extent to which our model represents a true realization of (M,R). We observe that under some starting conditions and parameter values, stable states can be achieved. Although formal demonstration of algorithmic computability remains elusive for (M,R), we discuss the extent to which our Bio-PEPA representation of (M,R) allows us to sidestep Rosen's fundamental objections to computational systems biology. We argue that the behaviour of (M,R) in Bio-PEPA shows life-like properties.

  4. MR-guided joint reconstruction of activity and attenuation in brain PET-MR

    DEFF Research Database (Denmark)

    Mehranian, Abolfazl; Zaidi, Habib; Reader, Andrew J

    2017-01-01

    by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this algorithm can be effectively addressed by imposing MR spatial constraints on the estimation of attenuation maps using a penalized MLAA (P-MLAA(+)) algorithm. With the advent of simultaneous PET-MR systems......, MRI-guided PET image reconstruction has also gained attention for improving the quantitative accuracy of PET images, usually degraded by noise and partial volume effects. The aim of this study is therefore to increase the benefits of MRI information for improving the quantitative accuracy of PET...... as a reference. The simulation results showed that the proposed method can notably improve the visual quality of the PET images by reducing noise while preserving structural boundaries and at the same time improving the quantitative accuracy of the PET images. Our clinical reconstruction results showed...

  5. Does MR imaging effectively replace diagnostic arthroscopy

    International Nuclear Information System (INIS)

    Ruwe, P.; McCarthy, S.; Wright, J.; Randall, L.; Lynch, K.; Jokyl, P.

    1990-01-01

    This paper determines if MR imaging reduces the number of diagnostic arthroscopic procedures required in patients with knee complaints and if MR imaging is cost-effective compared with diagnostic arthroscopy. The cohort analysis consists of 100 patients seen in a sports medicine clinic by two orthopedic surgeons who agreed on well-defined criteria for performing MR imaging and arthroscopy. Each orthopedic surgeon referring a patient for MR imaging checked a form regarding the plans for arthroscopy. Outcome analysis was conducted at 6 months

  6. Prostate cancer: a comparative study of {sup 11}C-choline PET and MR imaging combined with proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Takako; Lee, Jin; Takahashi, Nobukazu; Oka, Takashi; Shizukuishi, Kazuya; Inoue, Tomio [Yokohama City University School of Medicine, Department of Radiology, Yokohama (Japan); Uemura, Hiroji; Kubota, Yoshinobu [Yokohama City University School of Medicine, Department of Urology, Kanagawa (Japan); Sasaki, Takeshi [Yokohama City University School of Medicine, Department of Pathology, Kanagawa (Japan); Endou, Hisashi [Yokohama City University School of Medicine, Department of Pharmacy, Kanagawa (Japan)

    2005-07-01

    Prostate cancer is difficult to visualise in its early stages using current imaging technology. The present study aimed to clarify the utility of {sup 11}C-choline PET for localising and evaluating cancer lesions in patients with prostate cancer by conducting a prospective comparison with magnetic resonance (MR) imaging combined with proton MR spectroscopy. PET and MR imaging combined with proton MR spectroscopy were performed in 20 patients with prostate cancer. Correlations among the metabolite ratio of choline + creatine to citrate (Cho+Cr/Ci) on MR spectroscopy, serum PSA and maximum standardised uptake value (SUV{sub max}) of {sup 11}C-choline were assessed. The location of the primary lesion was assessed by the site of SUV{sub max} and the laterality of the highest Cho+Cr/Ci ratio and confirmed by examination of surgical pathology specimens (n=16). PET exhibited a diagnostic sensitivity of 100% (20/20) for primary lesions, while the sensitivities of MR imaging and MR spectroscopy were 60% (12/20) and 65% (13/20), respectively. Weak linear correlations were observed between SUV{sub max} and serum PSA (r=0.52, p<0.05), and between SUV{sub max} and Cho+Cr/Ci ratio (r=0.49, p<0.05). Regarding the localisation of main primary lesions, PET results agreed with pathological findings in 13 patients (81%) ({kappa}=0.59), while MR spectroscopy results were in accordance with pathological findings in eight patients (50%) ({kappa}=0.11). This preliminary study suggests that {sup 11}C-choline PET may provide more accurate information regarding the localisation of main primary prostate cancer lesions than MR imaging/MR spectroscopy. A further clinical study of {sup 11}C-choline PET in a large number of patients suspected of prostate cancer will be necessary to determine the clinical utility of {sup 11}C-choline PET in patients who clinically require biopsy. (orig.)

  7. MR imaging features of craniodiaphyseal dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Marden, Franklin A. [Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Blvd., MO 63110, St. Louis (United States); Department of Radiology, St. Louis Children' s Hospital, Children' s Place, MO 63110, St. Louis (United States); Wippold, Franz J. [Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Blvd., MO 63110, St. Louis (United States); Department of Radiology, St. Louis Children' s Hospital, Children' s Place, MO 63110, St. Louis (United States); Department of Radiology/Nuclear Medicine, F. Edward Hebert School of Medicine, Uniformed Services University of the Health Sciences, MD 20814, Bethesda (United States)

    2004-02-01

    We report the magnetic resonance (MR) imaging findings in a 4-year-old girl with characteristic radiographic and computed tomography (CT) features of craniodiaphyseal dysplasia. MR imaging exquisitely depicted cranial nerve compression, small foramen magnum, hydrocephalus, and other intracranial complications of this syndrome. A syrinx of the cervical spinal cord was demonstrated. We suggest that MR imaging become a routine component of the evaluation of these patients. (orig.)

  8. Modern MRI of the small bowell; Moderne MRT des Duenndarms

    Energy Technology Data Exchange (ETDEWEB)

    Scharitzer, M.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2015-12-15

    The radiological diagnostics of diseases of the small intestine have undergone a great change in the last two decades. Through rapid progress with new treatments and an increasing therapeutic focus on transmural healing, a complete evaluation of the gastrointestinal tract is now crucial. With the introduction of endoscopy, gastrointestinal imaging with a relatively high radiation exposure had only limited applications. The development of cross-sectional imaging allowed a much broader radiological evaluation of abdominal diseases. Due to rapid investigation techniques, excellent soft tissue contrast and the distinct advantage of eliminating exposure to radiation, magnetic resonance imaging (MRI) of the gastrointestinal tract has gained increasing importance. With sufficient filling of the intestinal lumen, simultaneous imaging of all the intestinal wall layers, the perienteric structures and associated abdominal pathologies is now possible. New MR sequences, such as diffusion-weighted sequences, dynamic contrast-enhanced sequences and MR fluoroscopy, enable the detection of morphological changes, with additional characterization of affected bowel loops as well as the assessment of functional pathologies with dynamic information about intestinal motility disturbances. Recent guidelines of European radiological and gastroenterological organizations have confirmed the importance of cross-sectional imaging and particularly of MRI for diagnostics and follow-up in patients with Crohn's disease. Due to the possibility of assessment of all the layers of the intestinal wall and the presence of extramural complications, MRI has a significant impact on further therapeutic treatment in patients with inflammatory bowel disease. Especially in patients with inflammatory bowel disease, MR enterography and MR enteroclysis should be the methods of choice for the evaluation of small bowel pathologies because of radiation issues and the great diagnostic value they provide. A

  9. MR arthrography: how I do it

    International Nuclear Information System (INIS)

    Bankaoglu, M.

    2012-01-01

    Full text: Magnetic resonance imaging has to rely on improving new various sequences and techniques and to get the best imaging quality so magnetic resonance (MR) arthrography is one of the most important technique in the assessment of selected musculoskeletal disorders. It is now widely utilized and considered by most musculoskeletal radiologists and some orthopedists to be an integral part of their clinical practice. The technique include: desired degree of joint distension with contrast medium; markedly improved imaging quality of intra-articular structures with the direct delineation so improved detection of pathology with MRI. As appliance and technique of MR arthrography is completely based on traditional arthrography of X ray. In MR arthrography additional very little amount of Gadolinium based contrast agent is added to the desired mixture of contrast material injected to the joint. As in conventional radiography MR arthrography is used to get extra information for conventional MRI . Practically any joint that can be accessed by a needle can be imaged using MR arthrography but it has been applied to limited number of joints to compare with the traditional arthrography so shoulder, knee, wrist, elbow, ankle, and hip are mostly subjects to do in MR arthrography. The procedure is also less invasive and expensive rather than diagnostic arthroscopy and should carefully indicated because it is not completely noninvasive technique so previous imaging modalities and MRI of the patients should be completed and evaluated well. During or after the procedure there has been no major complication reported by so far but more than two third of patients are known to complain some degree of pain right after or several times later than the procedure. As it is more than twenty years now it has been widely accepted helpful for diagnosis and adds some extra sensitivity to conventional MRI . Up to this time MR arthrography has proven to increase sensitivity of conventional MRI in

  10. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  11. Tumor-mimicking primary angiitis of the central nervous system: initial and follow-up MR features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youkyung; Kim, Ji-hoon; Kim, Eunhee; Yim, Yoo Jeong; Sohn, Chul-Ho [Department of Radiology, Seoul National University Hospital, Seoul (Korea); Park, Sung-Hye [Seoul National University, Department of Pathology, School of Medicine, Seoul (Korea); Chang, Kee-Hyun [Department of Radiology, Seoul National University Hospital, Seoul (Korea); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea); Seoul National University Medical Research Center, Neuroscience Research Institute, Seoul (Korea)

    2009-10-15

    Primary angiitis of the central nervous system (PACNS) is an extremely rare vasculitis of unknown etiology. The purpose of this study was to describe the initial and follow-up magnetic resonance (MR) imaging features of the tumor-mimicking PACNS. We retrospectively reviewed a total of 21 initial and follow-up brain MR images obtained in four patients with biopsy-proven PACNS mimicking brain tumor on MR images during the periods from 1 to 8.1 years. In the initial study, diffusion-weighted imaging (DWI; n=4), MR angiogram (n=4), conventional catheter angiogram (n=3), perfusion MR (n=1), and computed tomography (n=1) and proton MR spectroscopy (MRS; n=2) were included. The lesions of the brain were qualitatively assessed in terms of location, number, size, shape, signal intensity, absence or presence of hemorrhage, enhancement pattern, and changes on the follow-up studies. Initially, the lesion manifested as single suprasellar (n=1) and frontal hemispheric (n=1) mass and as multiple-enhancing lesions in the unilateral supratentorial hemisphere (n=2). A patient showed steno-occlusive lesions in the internal carotid and middle cerebral arteries. DWI, perfusion imaging, and MRS revealed inconsistent findings among the patients. On the follow-up studies, a patient had two relapses but there was either significant decrease in size and extent or disappearance of the lesions with immunosuppressive therapy in all patients. Tumor-mimicking PACNS shows variable features on initial MR images but shows good responses to appropriate immunosuppressive therapy on follow-up MR images. (orig.)

  12. Tumor-mimicking primary angiitis of the central nervous system: initial and follow-up MR features

    International Nuclear Information System (INIS)

    Lee, Youkyung; Kim, Ji-hoon; Kim, Eunhee; Yim, Yoo Jeong; Sohn, Chul-Ho; Park, Sung-Hye; Chang, Kee-Hyun

    2009-01-01

    Primary angiitis of the central nervous system (PACNS) is an extremely rare vasculitis of unknown etiology. The purpose of this study was to describe the initial and follow-up magnetic resonance (MR) imaging features of the tumor-mimicking PACNS. We retrospectively reviewed a total of 21 initial and follow-up brain MR images obtained in four patients with biopsy-proven PACNS mimicking brain tumor on MR images during the periods from 1 to 8.1 years. In the initial study, diffusion-weighted imaging (DWI; n=4), MR angiogram (n=4), conventional catheter angiogram (n=3), perfusion MR (n=1), and computed tomography (n=1) and proton MR spectroscopy (MRS; n=2) were included. The lesions of the brain were qualitatively assessed in terms of location, number, size, shape, signal intensity, absence or presence of hemorrhage, enhancement pattern, and changes on the follow-up studies. Initially, the lesion manifested as single suprasellar (n=1) and frontal hemispheric (n=1) mass and as multiple-enhancing lesions in the unilateral supratentorial hemisphere (n=2). A patient showed steno-occlusive lesions in the internal carotid and middle cerebral arteries. DWI, perfusion imaging, and MRS revealed inconsistent findings among the patients. On the follow-up studies, a patient had two relapses but there was either significant decrease in size and extent or disappearance of the lesions with immunosuppressive therapy in all patients. Tumor-mimicking PACNS shows variable features on initial MR images but shows good responses to appropriate immunosuppressive therapy on follow-up MR images. (orig.)

  13. Multipurpose simulator ''MR TRIOS'' for reprocessing plant

    International Nuclear Information System (INIS)

    Mitsui, Takeshi; Uehara, Shigeru; Takata, Hideo; Kamishima, Naoyuki

    1993-01-01

    MHI (Mitsubishi Heavy Industries) has developed MR TRIOS (Mitsubishi Reprocessing plant TRansient simulation code for Integrated process for Operation Support), the realtime dynamic simulator, for multipurpose use to support the Reprocessing Plant operation in various aspects. MR TRIOS integrates the Simulation Models of the unit process in a Reprocessing Plant, including Shearing, Dissolution, NOx absorption, Accountability and Adjustment and Co-decontamination process, where each Simulation Model has two kinds of models: Process and Control System. MR TRIOS can simulate the process behavior of the unit process in an integrated manner as well as independently. It is supported by MR CONTROL, the simulator control program developed by MHI. From MR TRIOS one can obtain real-time process values, such as temperature, pressure, density, flow rate, and concentration of nuclides, enabling the evaluation of the process dynamic characteristics under various operating conditions. MR TRIOS has proved to be an effective tool for the comprehensive study of the process and system dynamics, for operation technique improvements and for training

  14. High-field MR imaging of tethered cord

    International Nuclear Information System (INIS)

    Sigal, R.; Bicetre, L.; Blass, C.; Doyon, D.; Pariente, D.

    1986-01-01

    MR imaging examinations of 12 patients with tethered cord syndrome have been performed on a 1.5-T MR imaging unit. Patients ranged in age from 3 to 60 years. MR findings were compared with those of myelography and metrizamide CT in all cases. Five patients underwent surgical control and postoperative MR imaging. Sagittal and axial sections were obtained using a spin-echo multisection, multiecho technique. T1-axial weighted images (SE 600/25) were sufficient to locate the position of the tip of the conus. They also allowed identification of extraspinal and intraspinal lipomas and clear-cut demarcation form associated tethered cord. Drawbacks of MR imaging were lack of precise depiction of the bone structures and the fact that clear identification of abnormal roots was problematic. The craniovertebral junction was always checked; two asymptomatic Chiari malformations were visualized. This study leads the authors to conclude that MR imaging should be used as the examination of first choice in the management of tethered cord syndrome

  15. MR imaging of posttraumatic spinal ligament injury

    International Nuclear Information System (INIS)

    Pathria, M.N.; Emery, S.; Masaryk, T.J.; Wilber, R.G.; Bohlman, H.

    1988-01-01

    The accuracy of MR imaging in the detection of ligamentous injury was evaluated in 29 patients (24 male, five female) with spinal injury resulting in fractures (n=27), evidence of instability (n=11), or neurologic deficit (n=2). MR examinations were performed acutely (average, 7.5 days posttrauma) with T1- and T2-weighted imaging and were blindly evaluated. Subsequently, plain films (n=27), tomograms (n=10), and CT scans (n=22) were evaluated. Eighteen patients underwent surgery. Fourteen patients had torn ligaments as indicated by clinical and surgical findings. MR imaging demonstrated ligament damage in 13. One case imaged 40 days following trauma was not detected. No patients with intact ligaments had evidence of ligamentous damage on MR images. MR imaging demonstrated retropulsed fractures in six patients in whom the posterior longitudinal ligament was intact but displaced from the vertebra. MR imaging was more reliable than radiography and CT for detection of ligamentous injury, and T2- weighted sequences are essential in such cases

  16. Dynamic MR imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Shah, A.S.; Hylton, H.; Hentz, V.R.; Schattner, P.

    1991-01-01

    This paper reports on dynamic MR imaging which is an MR technique that allows imaging of the musculoskeletal system in motion. Current methods for observing the articulation of muscles and joints are limited to acquisition of stationary images at different spatial orientations. These images are then replayed from computer memory to simulate motion. Unlike stationary acquisition, dynamic MR imaging allows the volume of interest to be subjected to motion and dynamic stress, which is important for detecting stress-induced pathology. To demonstrate the utility of dynamic MR imaging, a system for imaging a moving wrist has been developed. The system consists of apparatus capable of providing simultaneous radialulnar deviation and flexion-extension, and hardware for system control and acquisition gating. The apparatus is mounted on the patient bed and is transferable to a variety of standard clinical MR imaging systems. Images were obtained during motion, and the ability of dynamic MR imaging to accurately image the moving wrist with very little motion artifact was demonstrated

  17. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  18. CEST and PARACEST MR contrast agents

    International Nuclear Information System (INIS)

    Hancu, Ileana; Dixon, W. Thomas; Woods, Mark; Sherry, A. Dean; Vinogradov, Elena; Lenkinski, Robert E.

    2010-01-01

    In this review we describe the status of development for a new class of magnetic resonance (MR) contrast agents, based on chemical exchange saturation transfer (CEST). The mathematics and physics relevant to the description of the CEST effect in MR are presented in an appendix published in the online version only. We discuss the issues arising when translating in vitro results obtained with CEST agents to using these MR agents in in vivo model studies and in humans. Examples are given on how these agents are imaged in vivo. We summarize the status of development of these CEST agents, and speculate about the next steps that may be taken towards the demonstration of CEST MR imaging in clinical applications

  19. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    Science.gov (United States)

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2

  20. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Heuck, A.; Appel, M.; Kaiser, E.; Luttke, G.; Lukas, P.

    1990-01-01

    This paper evaluates the occurrence, frequency, and significance of increased signal intensity (SI) in the rotator cuff (RC) of normal volunteers suggestive of pathologic findings such as partial tears and tendinitis. Shoulders of 30 volunteers without evidence of prior shoulder disease or trauma were studied. MR imaging at 1.5 T included T1-weighted, proton-density, and T2-weighted spin-echo (SE) and T2*-weighted gradient-echo sequences in axial, oblique coronal, and sagittal planes. Shoulders of 30 cadavers were dissected and studied for correlation with MR findings, five of them after MR examination

  1. Evaluation of Marfan syndrome: MR imaging versus CT

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fishman, E.K.; Pyeritz, R.E.; Gott, V.L.; Zerhouni, E.A.

    1986-01-01

    Twenty-five patients with Marfan, syndrome underwent both CT and MR imaging. MR imaging were interpreted in blinded fashion and then compared with CT scans MR imaging was found to be equivalent to CT in the detection of aortic, dural, and hip abnormalities in patients not operated on. MR imaging was superior to CT in the evaluation of postoperative patients because the artifact produced by Bjork-Shirley or St. Jude valves precludes adequate evaluation of the aortic root on CT while producing only a small inferior field distortion (a ''pseudo-ventricular septal defect'') on MR imaging. The absence of radiation exposure is another major advantage of MR imaging in this relatively young population requiring serial studies. The authors conclude that MR imaging is the modality of choice for the evaluation and follow-up of patients with Marfan syndrome and offers an appropriate means of screening their kindred

  2. How to perform and interpret cine MR enterography.

    Science.gov (United States)

    Wnorowski, Amelia M; Guglielmo, Flavius F; Mitchell, Donald G

    2015-11-01

    Magnetic resonance (MR) enterography has become a fundamental tool for small bowel evaluation. Multiphasic cine imaging is a useful component of MR enterography evaluation because it provides functional information about bowel motility. Cine MR enterography can be used to evaluate for strictures and adhesions. Bowel motility evaluation has been shown to increase pathologic lesion detection in Crohn's disease and has been incorporated into disease activity scoring systems. Currently, cine MR enterography remains underutilized. The purpose of this article is to outline how to perform and interpret cine MR enterography. The authors describe how to perform a multiphasic balanced steady state free precession sequence using different MR systems and give practical advice on how to display and interpret the cine sequence. Sample cases illustrate how the cine sequence complements standard MR enterography evaluation with T2 -weighted, contrast-enhanced T1 -weighted, and diffusion-weighted imaging. © 2015 Wiley Periodicals, Inc.

  3. MR findings of cerebral palsy

    International Nuclear Information System (INIS)

    Yoon, Sang Hum; Chang, Seung Kuk; Cho, Mee Young; Park, Dong Woo; Kim, Jong Deok; Eun, Choong Ki

    1994-01-01

    To evaluate the MR findings of brain damage in cerebral palised patients and to correlate it with gestational age and the time of damage. A retrospective analysis was performed in 40 patients who underwent MR scanning for evaluation of brain lesion in clinically diagnosed cerebral palsy. Authors classified the patients into two groups as premature and full-term and compared MR findings of the two groups. Abnormal MR findings were noted in 28 cases (70%). Five out of 6 patients who had been born prematurely showed isolate periventricular white matter lesions. Twenty-three out of 34 patients who had been born at full-term showed abnormal MR findings. Of these 23 patients, migration anomalies in 7 patients, isolate periventricular white matter lesions in 3 patients, and other combined periventricular subcortical white matter and deep gray matter lesions in 14 patients were seen. At least, 10 patients(43%) of full term group showed abnormal MRI findings reflecting intrauterine brain damage and all 5 patients of premature group showed isolate periventricular white matter lesions suggesting immaturity of brain. MRI is thought to be very useful in the assessment of brain damage for the patients with cerebral palsy by recognizing the location of the lesion and estimating the time of damage

  4. MR findings of cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Hum; Chang, Seung Kuk; Cho, Mee Young; Park, Dong Woo; Kim, Jong Deok; Eun, Choong Ki [Pusan Paik Hospital, Pusan (Korea, Republic of)

    1994-11-15

    To evaluate the MR findings of brain damage in cerebral palised patients and to correlate it with gestational age and the time of damage. A retrospective analysis was performed in 40 patients who underwent MR scanning for evaluation of brain lesion in clinically diagnosed cerebral palsy. Authors classified the patients into two groups as premature and full-term and compared MR findings of the two groups. Abnormal MR findings were noted in 28 cases (70%). Five out of 6 patients who had been born prematurely showed isolate periventricular white matter lesions. Twenty-three out of 34 patients who had been born at full-term showed abnormal MR findings. Of these 23 patients, migration anomalies in 7 patients, isolate periventricular white matter lesions in 3 patients, and other combined periventricular subcortical white matter and deep gray matter lesions in 14 patients were seen. At least, 10 patients(43%) of full term group showed abnormal MRI findings reflecting intrauterine brain damage and all 5 patients of premature group showed isolate periventricular white matter lesions suggesting immaturity of brain. MRI is thought to be very useful in the assessment of brain damage for the patients with cerebral palsy by recognizing the location of the lesion and estimating the time of damage.

  5. MR imaging of spinal trauma

    International Nuclear Information System (INIS)

    Buchberger, W.; Springer, P.; Birbamer, G.; Judmaier, W.; Kathrein, A.; Daniaux, H.

    1995-01-01

    To assess the value of MR imaging in the acute and chronic stages of spinal trauma. 126 MR examinations of 120 patients were evaluated retrospectively. In 15 cases of acute spinal cord injury, correlation of MR findings with the degree of neurological deficit and eventual recovery was undertaken. Cord anomalies in the acute stage were seen in 16 patients. Intramedullary haemorrhage (n=6) and cord transection (n=2) were associated with complete injuries and poor prognosis, whereas patients with cord oedema (n=7) had incomplete injuries and recovered significant neurological function. In the chronic stage, MR findings included persistent cord compression in 8 patients, syringomyelia or post-traumatic cyst in 12, myelomalacia in 6, cord atrophy in 9, and cord transection in 7 patients. In acute spinal trauma, MR proved useful in assessing spinal cord compression and instability. In addition, direct visualisation and characterisation of posttraumatic changes within the spinal cord may offer new possibilities in establishing the prognosis for neurological recovery. In the later stages, potentially remediable causes of persistent or progressive symptoms, such as chronic spinal cord compression or syringomyelia can be distinguished from other sequelae of spinal trauma, such as myelomalacia, cord transection or atrophy. (orig.) [de

  6. Role of MR imaging in chronic wrist pain

    Energy Technology Data Exchange (ETDEWEB)

    Zanetti, Marco; Saupe, Nadja [University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Nagy, Ladislav [University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland)

    2007-04-15

    Magnetic resonance (MR) imaging for chronic wrist pain is challenging. Correct assessment of the triangular fibrocartilage, hyaline cartilage, ligaments, and tendons has become mandatory for comprehensive decision making in wrist surgery. The MR technique, potential and limits of MR imaging in patients with chronic wrist pain will be discussed. MR arthrography with injection of gadolinium-containing contrast material into the distal radioulnar joint is suggested for evaluation of the triangular fibrocartilage. The clinically meaningful ulnar-sided peripheral tears are otherwise hard to diagnose. The diagnostic performance of MR imaging for interosseous ligament tears varies considerably. The sensitivity for scapholunate ligament tears is consistently better than for lunotriquetral ligament tears. Gadolinium-enhanced MR imaging is considered to be the best technique for detecting established avascularity of bone, but the assessment of the MR results remains challenging. Most cases of ulnar impaction syndrome have characteristic focal signal intensity changes in the ulnar aspect of the lunate. Avascular necrosis of the lunate (Kienboeck's disease) is characterized by signal changes starting in the proximal radial aspect of the lunate. MR imaging is extremely sensitive for occult fractures. Questions arise if occult posttraumatic bone lesions seen on MR images only necessarily require the same treatment as fractures evident on plain films or computed tomography (CT) images. MR imaging and ultrasound are equally effective for detecting occult carpal ganglia. Carpe bossu (carpal boss) is a bony protuberance of a carpometacarpal joint II and III which may be associated with pain. (orig.)

  7. Role of MR imaging in chronic wrist pain

    International Nuclear Information System (INIS)

    Zanetti, Marco; Saupe, Nadja; Nagy, Ladislav

    2007-01-01

    Magnetic resonance (MR) imaging for chronic wrist pain is challenging. Correct assessment of the triangular fibrocartilage, hyaline cartilage, ligaments, and tendons has become mandatory for comprehensive decision making in wrist surgery. The MR technique, potential and limits of MR imaging in patients with chronic wrist pain will be discussed. MR arthrography with injection of gadolinium-containing contrast material into the distal radioulnar joint is suggested for evaluation of the triangular fibrocartilage. The clinically meaningful ulnar-sided peripheral tears are otherwise hard to diagnose. The diagnostic performance of MR imaging for interosseous ligament tears varies considerably. The sensitivity for scapholunate ligament tears is consistently better than for lunotriquetral ligament tears. Gadolinium-enhanced MR imaging is considered to be the best technique for detecting established avascularity of bone, but the assessment of the MR results remains challenging. Most cases of ulnar impaction syndrome have characteristic focal signal intensity changes in the ulnar aspect of the lunate. Avascular necrosis of the lunate (Kienboeck's disease) is characterized by signal changes starting in the proximal radial aspect of the lunate. MR imaging is extremely sensitive for occult fractures. Questions arise if occult posttraumatic bone lesions seen on MR images only necessarily require the same treatment as fractures evident on plain films or computed tomography (CT) images. MR imaging and ultrasound are equally effective for detecting occult carpal ganglia. Carpe bossu (carpal boss) is a bony protuberance of a carpometacarpal joint II and III which may be associated with pain. (orig.)

  8. Multidisciplinary Functional MR Imaging for Prostate Cancer

    International Nuclear Information System (INIS)

    Kim, Jeong Kon; Jang, Yun Jin; Cho, Gyung Goo

    2009-01-01

    Various functional magnetic resonance (MR) imaging techniques are used for evaluating prostate cancer including diffusion-weighted imaging, dynamic contrast- enhanced MR imaging, and MR spectroscopy. These techniques provide unique information that is helpful to differentiate prostate cancer from non-cancerous tissue and have been proven to improve the diagnostic performance of MRI not only for cancer detection, but also for staging, post-treatment monitoring, and guiding prostate biopsies. However, each functional MR imaging technique also has inherent challenges. Therefore, in order to make accurate diagnoses, it is important to comprehensively understand their advantages and limitations, histologic background related with image findings, and their clinical relevance for evaluating prostate cancer. This article will review the basic principles and clinical significance of functional MR imaging for evaluating prostate cancer

  9. Drug-induced MR urography: the effects of furosemide and intravenous saline injection on MR urography of obstructed and non-obstructed urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Ha; Lee, Myung Jun; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    2001-10-01

    To determine the usefulness of MR urography technique for the evaluation of urinary systems in patients with obstructed urinary tract and normal volunteers with non-obstructed urinary tract after intravenous normal saline and diuretic injection. Three normal volunteers and 12 patients with urinary tract obstruction [ureteral calculi (n=8), extraurinary mass (n=1), ureteral tumor invasion (n=3)] underwent MR urography using a 1.0T scanner and a 2D non-breath-hold heavily T2-weighted fast spin-cho sequence. These acquisition were post-processed with a maximum intensity projection (MIP) algorithm. Two acquisitions were performed, the first prior to saline solution infusion following standard MR urography procedures, and the second, within 2-3 minutes of the infusion of 250 ml saline solution followed by 20 mg of Lasix administered intravenously. For this latter, drug-induced MR urography procedures were followed. In healthy volunteer (n=3) and those experiencing partial obstruction (n=4) by a urinary stone, drug-induced MR urography provided better images of the urinary tract than did standard MR urography. In those in whom a urinary stone or tumor had caused complete obstruction (n=8), standard MR urography provided good images, as did drug-induced MR urography. In patients with a partially or non-obstructed urinary tract, drug-induced MR urography provided better anatomic and functional details of the kidney and urinary tract than did standard MR urography. In those experiencing complete obstruction of the urinary tract, however, standard or drug-induced MR urography permitted very adequate evaluation of the tract, and drug-induced MR urography was unnecessary.

  10. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  11. Overhauser-enhanced MR imaging (OMRI)

    DEFF Research Database (Denmark)

    Golman, K; Leunbach, I; Ardenkjaer-Larsen, JH

    1998-01-01

    Purpose. To evaluate a new single-electron contrast agent for Overhauser-enhanced MR imaging. The contrast agents that are currently available give enhancement factors that are too low to make the technique a valid option for routine clinical use. Material and Methods. MR images were generated di...

  12. Rapid myelin water content mapping on clinical MR systems

    International Nuclear Information System (INIS)

    Tonkova, Vyara; Arhelger, Volker; Schenk, Jochen; Neeb, Heiko; Koblenz Univ.

    2012-01-01

    We present an algorithm for the fast mapping of myelin water content using standard multiecho gradient echo acquisitions of the human brain. The method extents a previously published approach for the simultaneous measurement of brain T 1 , T * 2 and total water content. Employing the multiexponential T * 2 decay signal of myelinated tissue, myelin water content was measured based on the quantification of two water pools ('myelin water' and 'rest') with different relaxation times. As the existing protocol was focussed on the fast mapping of quantitative MR parameters with whole brain coverage in clinically relevant measurement times, the sampling density of the T * 2 curve was compromised to 10 echo times with a T Emax of approx. 40 ms. Therefore, pool amplitudes were determined using a quadratic optimisation approach. The optimisation was constrained by including a priori knowledge about brain water pools. All constraints were optimised in a simulation study to minimise systematic error sources given the incomplete knowledge about the real pool-specific relaxation properties. Based on the simulation results, whole brain in vivo myelin water content maps were acquired in 10 healthy controls and one subject with multiple sclerosis. The in vivo results obtained were consistent with previous reports which demonstrates that a simultaneous whole brain mapping of T 1 , T * 2 , total and myelin water content is feasible on almost any modern MR scanner in less than 10 minutes. (orig.)

  13. Cross-calibration of the Siemens mMR

    DEFF Research Database (Denmark)

    Keller, Sune H; Jakoby, Björn; Svalling, Susanne

    2016-01-01

    BACKGROUND: We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens Biograph mMR PET/MR system. We perform regular cross-calibrations (Xcal) of our PET systems, including the PET/MR, using a Siemens mCT water...

  14. MR staging of endometrial carcinoma

    International Nuclear Information System (INIS)

    Innocenti, P.; Agostini, S.; Erroi, C.; Ambrogetti, D.; Cellerini, A.; Nori, J.

    1991-01-01

    Biopsy is the technique of choice for the definitive diagnosis of endometrial carcinoma. Since lymphatic tumor spread has been demonstrated to depend on the degree of myometrial involvement, the definition of the latter with imaging techniques may significantly affect both pfognosis and therapy. We investigated, by means of MR imaging at 0.5 T, 14 patients with endometrial carcinoma, to assess both tumor stage and myometrial involvement. FIGO staging system was employed, and M parameter evaluated (M0= no myometrial involvement; M1involvement confined to the inner third; M2= Involvement confined to the middle third; M3= involvement of the whole myometrium). Another parameter was the characteristic high signal of the tumor on PD and T2W images. The patients were then operated and MR information was correlated with surgical findings. Overall diagnostic accuracy of MR imaging was 85.7% in tumor staging, and 92.2% in defining M parameter. Tumor spread into adnexa and into cervical canal was poorly demonstrated by MR imaging

  15. Technical errors in MR arthrography

    International Nuclear Information System (INIS)

    Hodler, Juerg

    2008-01-01

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  16. Technical errors in MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Hodler, Juerg [Orthopaedic University Hospital of Balgrist, Radiology, Zurich (Switzerland)

    2008-01-15

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  17. MR constrained simultaneous reconstruction of activity and attenuation maps in brain TOF-PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mehranian, Abolfazl; Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland)

    2014-07-29

    The maximum likelihood estimation of attenuation and activity (MLAA) algorithm has been proposed to jointly estimate activity and attenuation from emission data only. Salomon et al employed the MLAA to estimate activity and attenuation from time-of-flight PET data with spatial MR prior information on attenuation. Recently, we proposed a novel algorithm to impose both spatial and statistical constraints on attenuation estimation within the MLAA algorithm using Dixon MR images and a constrained Gaussian mixture model (GMM). In this study, we compare the proposed algorithm with MLAA and MLAA-Salomon in brain TOF-PET/MR imaging.

  18. MR constrained simultaneous reconstruction of activity and attenuation maps in brain TOF-PET/MR imaging

    International Nuclear Information System (INIS)

    Mehranian, Abolfazl; Zaidi, Habib

    2014-01-01

    The maximum likelihood estimation of attenuation and activity (MLAA) algorithm has been proposed to jointly estimate activity and attenuation from emission data only. Salomon et al employed the MLAA to estimate activity and attenuation from time-of-flight PET data with spatial MR prior information on attenuation. Recently, we proposed a novel algorithm to impose both spatial and statistical constraints on attenuation estimation within the MLAA algorithm using Dixon MR images and a constrained Gaussian mixture model (GMM). In this study, we compare the proposed algorithm with MLAA and MLAA_Salomon in brain TOF-PET/MR imaging.

  19. Value of MR-guided localization and biopsy in breast lesions; Stellenwert der MR-gestuetzten Lokalisation und Biopsie von Brustlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Grabbe, E.; Knollmann, F. [Abt. Diagnostische Radiologie, Georg-August-Univ. Goettingen (Germany)

    2006-05-15

    Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i.e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guide intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature. (orig.)

  20. MrGrid: a portable grid based molecular replacement pipeline.

    Directory of Open Access Journals (Sweden)

    Jason W Schmidberger

    Full Text Available BACKGROUND: The crystallographic determination of protein structures can be computationally demanding and for difficult cases can benefit from user-friendly interfaces to high-performance computing resources. Molecular replacement (MR is a popular protein crystallographic technique that exploits the structural similarity between proteins that share some sequence similarity. But the need to trial permutations of search models, space group symmetries and other parameters makes MR time- and labour-intensive. However, MR calculations are embarrassingly parallel and thus ideally suited to distributed computing. In order to address this problem we have developed MrGrid, web-based software that allows multiple MR calculations to be executed across a grid of networked computers, allowing high-throughput MR. METHODOLOGY/PRINCIPAL FINDINGS: MrGrid is a portable web based application written in Java/JSP and Ruby, and taking advantage of Apple Xgrid technology. Designed to interface with a user defined Xgrid resource the package manages the distribution of multiple MR runs to the available nodes on the Xgrid. We evaluated MrGrid using 10 different protein test cases on a network of 13 computers, and achieved an average speed up factor of 5.69. CONCLUSIONS: MrGrid enables the user to retrieve and manage the results of tens to hundreds of MR calculations quickly and via a single web interface, as well as broadening the range of strategies that can be attempted. This high-throughput approach allows parameter sweeps to be performed in parallel, improving the chances of MR success.

  1. MR imaging of central nervous system birth injuries

    International Nuclear Information System (INIS)

    Heier, L.A.; Zimmerman, R.D.

    1991-01-01

    This paper reports on head injuries due to birth trauma that have been evaluated with plain radiography, US, and CT. In the past, patient monitoring and transportation difficulties for a neonate have limited the use of MR. Does MR provide more information that would assist the management and prognostic assessment of these patients? An MR examination was requested on all neonates born or transferred to our institution with a documented traumatic delivery. CT and MR studies were compared for seven patients, including three cases of difficult forceps delivery, one case of double footling breech with forceps head extraction, two cases of shoulder dystocias, and one case of vacuum extraction. CT caused underestimation of subdural hematomas and contusions in three of five patients with this injury. The appreciation of a large subdural hematoma at MR resulted in surgical intervention. Both unsuspected cervical cord contusion and complete cord transection were identified on sagittal head MR images. Four of four skull fractures identified at CT were not seen at MR

  2. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  3. MR tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Rinast, E.; Weiss, H.D.; Pressler, M.; Vogel, H.

    1989-03-01

    MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.

  4. MR imaging of normal bone marrow

    International Nuclear Information System (INIS)

    Stajgis, M.; Paprzycki, W.

    1994-01-01

    Principles of MR bone marrow imaging on the basis of retrospective analysis of MR examinations of bone marrow in different anatomic sites in 200 patients have been discussed. Significance of different physiologic factors and processes such as age, steatosis, osteoporosis, conversion and reconversion, which influence on MR bone marrow images, have been emphasized. T1-weighted images obtained with spin-echo sequences give the most of information about bone marrow structure in MR. Thorough knowledge of bone marrow physiology and clinical status of the patient is indispensable in correct interpretation of hypointensive lesions on T1-weighted images. When presence of disseminated bone marrow disease is suspected, authors propose routine imaging of lumbar vertebral column, pelvis and proximal parts of femoral bones. (author)

  5. Rosen's (M,R) system in Unified Modelling Language.

    Science.gov (United States)

    Zhang, Ling; Williams, Richard A; Gatherer, Derek

    2016-01-01

    Robert Rosen's (M,R) system is an abstract biological network architecture that is allegedly non-computable on a Turing machine. If (M,R) is truly non-computable, there are serious implications for the modelling of large biological networks in computer software. A body of work has now accumulated addressing Rosen's claim concerning (M,R) by attempting to instantiate it in various software systems. However, a conclusive refutation has remained elusive, principally since none of the attempts to date have unambiguously avoided the critique that they have altered the properties of (M,R) in the coding process, producing merely approximate simulations of (M,R) rather than true computational models. In this paper, we use the Unified Modelling Language (UML), a diagrammatic notation standard, to express (M,R) as a system of objects having attributes, functions and relations. We believe that this instantiates (M,R) in such a way than none of the original properties of the system are corrupted in the process. Crucially, we demonstrate that (M,R) as classically represented in the relational biology literature is implicitly a UML communication diagram. Furthermore, since UML is formally compatible with object-oriented computing languages, instantiation of (M,R) in UML strongly implies its computability in object-oriented coding languages. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. MR Imaging of Articular Hyaline Cartilage

    OpenAIRE

    Uetani, Masataka

    2005-01-01

    MR imaging is still an evolving technique for the diagnosis of joint cartilage lesions. Early morphologic changes in the degenerative cartilage are not reliably diagnosed even with use of tailored MR imaging techniques. The detection of the biochemical changes of cartilage or high-resolution MRI will serve as an important tool for the early diagnosis of cartilage degeneration in near future. Further prospective studies are needed to establish the role of MR imaging in clinical use.

  7. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    Science.gov (United States)

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude

  8. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  9. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  10. Proton MR spectroscopy in connatal Pelizaeus-Merzbacher disease

    International Nuclear Information System (INIS)

    Spalice, A.; Parisi, P.; Iannetti, P.; Popolizio, T.; Scarabino, T.

    2000-01-01

    Background. Pelizaeus-Merzbacher disease (PMD) is a rare dysmyelinating disorder characterised by early pendular nystagmus, often rotatory and muscular hypotonia with subsequent ataxia, spasticity and mental retardation. Various point mutations or duplications in the PLP gene on the X chromosome are responsible for PMD in the majority of patients. Autosomal recessive inheritance, particularly in the connatal form, cannot be excluded. Three different forms of the disease have been identified based on their onset, progression and severity of myelin pathology indicated by MRI features.Objective. To determine if MR spectroscopy is useful in the diagnosis of the connatal form of PMD.Materials and methods. Proton MR spectroscopy was performed on two children with connatal PMD.Results. Our patients showed a markedly decreased peak of Cho. This alteration is well represented by quantitative analysis of the NAA-to-Cho ratio, which is the most important ratio affected. A significant decrease of the Cho-to-Cr ratio is also present. In the connatal form of PMD, global lack of myelination may be relevant, as demonstrated by a significant Cho peak reduction.Conclusions. Proton MR spectroscopy may be of diagnostic value in metabolic and destructive disorders of the brain. A greater number of patients with connatal PMD is needed in order to elucidate the significance of reduction of the Cho peak. (orig.)

  11. MR imaging of chondramalacia patella

    International Nuclear Information System (INIS)

    Yulish, B.S.; Montanez, J.; Mulopulos, G.P.; Goodfellow, D.; Dollinger, B.; Bryan, P.J.; Modic, M.T.

    1986-01-01

    Because of its inherent soft-tissue contrast, MR imaging can distinguish hyaline articular cartilage, fibrocartilage, and cortical and medullary bone, and thus seems a method ideally suited to examine the posterior patellar hyaline articular cartilage. The authors studied the knees of people with suspected chondromalacia patella using MR imagine and compared our findings to normal knees and, where available, results of surgery. They find that we can distinguish swollen cartilage, irregular cartilage, absent cartilage, and bony patellar defects. Joint fluid and meniscal injuries could also be identified. MR imaging is a useful method for evaluation of chondromalacia patella and may reduce the need for arthroscopy and arthrography for diagnosis

  12. MR imaging of the knee

    International Nuclear Information System (INIS)

    Mink, J.H.

    1987-01-01

    There is increasing evidence that MR imaging of the knee can accurately evaluate the menisci and the cruciate and collateral ligaments with an accuracy equal to that of conventional anthrography. MR imaging can, as a simple test, definitively assess a wide spectrum of the causes of knee pain, including osteonecrosis/osteochondritis dissecans, chondral and bony fractures, abnormal plicae, and chondromalacia. The presentation focuses on the optimal imaging parameters that will ensure accuracy and maximize patient throughput. The etiology and significance of meniscal signal is discussed, and the criteria for an MR imaging-based diagnosis of meniscal tears, cruciate and collateral ligament and extensor mechanism abnormalities, osteonecrosis, and stress fractures are presented

  13. The use of MR in cardiological diagnostics

    International Nuclear Information System (INIS)

    Smith, Hans-Joergen

    2004-01-01

    Image diagnostics is playing an important role in cardiology, and magnetic resonance tomography (MR) is one of many methods used in examinations of the heart. Based on studies of the literature and his own experience the author surveys the potential of MR in today's and tomorrow's diagnostics of heart diseases. Among the image diagnostic methods MR is the one that can give the most extensive information about the heart's anatomy and function. In a non-invasive way and without the use of ionizing radiation, MR can represent the anatomy in selectable planes, visualize and quantify the heart's pumping function and functioning of the cardiac valves, and give detailed information about the regional contractility, blood flow and viability of myocard. MR is capable of giving important and to some extent unique contributions to heart diseases, both congenital and contracted heart disease. Because of failing availability and competence MR is still little used in cardiological diagnostics, but the method undoubtedly has the potential to play a very important role in the future

  14. MR angiography of the TMJ in asymptomatic volunteers

    International Nuclear Information System (INIS)

    Takagi, Ritsuo; Ohashi, Yasushi; Westesson, P.L.; Togashi, Hirosuke

    1998-01-01

    To evaluate the vascular anatomy of the temporomandibular joint (TMJ) and surrounding soft tissue non-invasively, we applied magnetic resonance (MR) angiography for delineating the arterial architecture around the TMJ. MR angiograms of the left and right TMJs in asymptomatic volunteers were obtained using 3D/Time-of-flight (TOF) (First Field Echo, TR/TE/FLIP=46 ms/6.8 ms/17 deg) with intravenous contrast. These MR angiograms were compared with experimental angiograms of human TMJ autopsy specimens in order to identify each of the branches of the arteries on the MR angiograms. This study enabled the depiction by MR angiography of arterial vessels around the TMJ region to some degree. In conclusion, MR angiography appears promising as a non-invasive tool to evaluate the vascular anatomy of the TMJ. (author)

  15. Fundamentals of combustion research. Final report 2000; Grundlagen der Verbrennungsforschung. Abschlussbericht 2000

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    All ten projects were aimed at modelling and validation of practically relevant natural gas flames. Modelling comprises the use,l development and enhancement of advanced combustion and turbulence models, e.g. PDF models or higher order Reynolds stress models. Validation uses modern laser diagnostics, e.g. spontaneous Raman scattering, LIF spectroscopy, and LDA. The practical applicability is ensured by a 150 kW flame whose characteristics can be extrapolated to industrial-scale plants. For this, four identical experiments were set up in the TECFLAM institutes of Stuttgart, Karlsruhe, Heidelberg, and Darmstadt. [German] Gemeinsames Projektziel der vorliegenden zehn Vorhaben ist die Modellentwicklung und Validierung anwendungsnaher Erdgasflammen. Unter Modellentwicklung ist dabei die Nutzung, Entwicklung und Weiterentwicklung fortschrittlicher Verbrennungs- und Turbulenzmodelle wie PDF-Modelle oder Reynolds-Stress-Modelle hoeherer Ordnung zu verstehen. Validierung wird durchgefuehrt mittels moderner Laserdiagnostik-Verfahren, wie der spontanen Raman-Streuung, der LIF-Spektroskopie sowie LDA-Verfahren. Die Anwendungsnaehe wird sichergestellt durch eine Flamme mit 150 kW Leistung, deren Verhalten auf grosstechnische Anlagen extrapolierbar ist. Um dieses ehrgeizige Ziel zu erreichen, wurden vier identische Versuchsaufbauten in den TECFLAM-Instituten in Stuttgart, Karlsruhe, Heidelberg und Darmstadt errichtet. (orig.)

  16. Postoperative MR arthography of the shoulder joint; MR-Arthographie des Schultergelenks im postoperativen Patientenkollektiv

    Energy Technology Data Exchange (ETDEWEB)

    Rand, T. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Trattnig, S. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Breitenseher, M. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Freilinger, W. [Orthopaedisches Krankenhaus Speising (Austria); Cochole, M. [Orthopaedische Abt., Allgemein Oeffentliches Krankenhaus Amstetten (Austria); Imhof, H. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria)

    1996-12-01

    Indications of MR arthrography were analyzed in this prospective study. The aim was to evaluate possible advantages over conventional MRI, establish diagnostic criteria and to analyze its meaning further for the therapeutic management of postoperative patients. MR arthrography was performed in eight patients who had undergone surgical repair of rotator cuff lesions (modified Neer acromioplasty) and in six patients who had undergone arthroscopic therapy of recurrent unidirectional dislocation of the shoulder by combined arthroscopic intra- and extracapsular repair. MR investigations were performed before and after application of a contrast solution (2 mmol Gd-DTPA). All patients suffered from chronic postoperative pain. In patients with rotator cuff lesions, a partial tear could be verified in one patient and excluded in all others. In patients after arthroscopic therapy by combined intra- and extracapsular repair, a radiologically patulous-appearing capsule correlated with clinically recurrent dislocations. In all other patients diagnostic criteria, such as distribution of the intra-articular contrast solution, proliferation of scar tissue, nodular appearance of the glenohumeral ligaments and capsule thickness, correlated with a regular postoperative status. MR arthrography of the shoulder represents a promising method in the evaluation of the postoperative shoulder. It might further improve the evaluation of reactive capsule alterations, scar tissue proliferation, and the labroligamentous complex, as well as the ability to differentiate partial and complete rerupture from degenerative changes of the rotator cuff. (orig.) [Deutsch] In einer prospektiven Studie sollten die Einsatzmoeglichkeiten der MR-Arthrographie am operierten Schultergelenk erfasst werden. Ziel der Studie war einerseits eine gegenueber der konventionellen MR-Untersuchung verbesserten Diagnosestellung und andererseits die Erstellung von fuer die Rezidivdiagnostik relevanten Diagnosekriterien

  17. Prüfungen zur Beurteilung der Brandgefahr; Beispiele für Verfahren zur Beurteilung einer Brandgefahr und für die Auslegung von Ergebnissen; 3.1: Kennwerte der Verbrennung und Übersicht über Prüfverfahren zu ihrer Ermittlung; Identisch mit IEC 60695-3-1, Ausgabe 1982

    CERN Document Server

    Deutsches Institut für Normung. Berlin

    1986-01-01

    Prüfungen zur Beurteilung der Brandgefahr; Beispiele für Verfahren zur Beurteilung einer Brandgefahr und für die Auslegung von Ergebnissen; 3.1: Kennwerte der Verbrennung und Übersicht über Prüfverfahren zu ihrer Ermittlung; Identisch mit IEC 60695-3-1, Ausgabe 1982

  18. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  19. An MR-compatible neonatal incubator.

    Science.gov (United States)

    Paley, M N J; Hart, A R; Lait, M; Griffiths, P D

    2012-07-01

    To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost.

  20. German Roentgen Society statement on MR imaging of patients with cardiac pacemakers; Positionspapier der Deutschen Roentgengesellschaft (DRG) zu MR-Untersuchungen bei Patienten mit Herzschrittmachern

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T. [German Red Cross Hospital Neuwied (Germany). Dept. of Diagnostic and Interventional Radiology; Luechinger, R. [Zuerich Univ. (Switzerland). Inst. for Biomedical Engineering; Barkhausen, J. [University Hospital Luebeck (Germany). Dept. of Radiology and Nuclear Medicine; Gutberlet, M. [Univ. Leipzig - German Heart Center Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology; Quick, H.H. [University Hospital Essen (Germany). Erwin L. Hahn Inst. for MR Imaging, High Field and Hybrid MR Imaging; Fischbach, K. [University Hospital Magdeburg (Germany). Dept. of Radiology and Nuclear Medicine

    2015-09-15

    The aim of this paper is to inform physicians, especially radiologists and cardiologists, about the technical and electrophysiological background of MR imaging of patients with implanted cardiac pacemakers (PM) and to provide dedicated clinical practice guidelines how to perform MR exams in this patient group. The presence of a conventional PM system is not any more considered an absolute contraindication for MR imaging. The prerequisites for MR imaging on pacemaker patients include the assessment of the individual risk/benefit ratio as well as to obtain full informed consent about the off label character of the procedure and all associated risks. Furthermore the use of special PM-related (e.g. re-programming of the PM) and MRI-related (e.g. limitation of whole body SAR to 2 W/kg) precautions is required and needs to be combined with adequate monitoring during MR imaging using continuous pulsoximetry. MR conditional PM devices are tested and approved for the use in the MR environment under certain conditions, including the field strength and gradient slew rate of the MR system, the maximum whole body SAR value and the presence of MR imaging exclusion zones. Safe MR imaging of patients with MR conditional PM requires the knowledge of the specific conditions of each PM system. If MR imaging within these specific conditions cannot be guaranteed in a given patient, the procedure guidelines for conventional PM should be used. The complexity of MR imaging of PM patients requires close cooperation of radiologists and cardiologists.

  1. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer; MRT-gezielte interventionelle Verfahren zur Abklaerung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Division fuer Molekulare und Gender-Bildgebung, Wien (Austria); Margreiter, M. [Medizinische Universitaet Wien, Univ.-Klinik fuer Urologie, Wien (Austria)

    2011-11-15

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [German] Neben dem transrektalen Ultraschall (TRUS) hat sich in den letzten Jahren die MRT als nichtinvasive Methode zur Bildgebung von Prostatatumoren etabliert. Mittels T2-gewichteter Sequenzen ist eine exakte anatomische Darstellung der Prostata und ihrer umliegenden Strukturen moeglich. Andere MRT-Techniken ermoeglichen Rueckschluesse auf das biologische Verhalten des Tumors: dynamische kontrastmittelverstaerkte T1-gewichtete Sequenzen zur Darstellung der Angiogenese, diffusionsgewichtete Aufnahmen zur Beurteilung der Zelldichte und die Spektroskopie zur Bestimmung von Gewebemetaboliten wie Cholin und Kreatin (multiparametrische Bildgebung). Prostatatumoren, die nur mittels MRT nachweisbar sind oder verdaechtige Tumoren, die hauptsaechlich anterior in der Prostata lokalisiert sind und in wiederholten TRUS-gezielten Biopsien verfehlt wurden, benoetigen eine MRT-gezielte Biopsie zur Diagnosesicherung. Die bisherigen

  2. MR imaging of sacral and perisacral lesions

    International Nuclear Information System (INIS)

    Wetzel, L.H.; Levine, E.; Murphey, M.D.

    1987-01-01

    This exhibit demonstrates the utility of MR imaging in evaluating sacral and perisacral lesions. Thirty-two lesions were studied using a superconducting 1.0-T MR imager. Eleven primary and 13 metastatic tumors, four congenital lesions, and four arachnoid cysts were evaluated. MR did not usually enable a more specific histologic diagnosis than other imaging techniques. However, extraosseous and proximal spinal extent of tumors was well defined without use of oral or intravenous contrast material. MR imaging is an excellent noninvasive technique for evaluating most sacral and perisacral lesions and is particularly helpful when precise tumor extent must be determined for treatment planning

  3. Requirements of modernization strategies

    International Nuclear Information System (INIS)

    Heinbuch, R.

    1997-01-01

    Instrumentation and control contributed a major share to the current level of safety, economic efficiency, and availability of the German nuclear power plants. German NPPs occupy a top position in this respect at international level, but novel instrumentation and digital control technology alone will not guarantee further enhancements. Therefore, the owner/operators established carefully devised maintenance and modernization strategies in order to safeguard their NPPs top position in the long run. The German NPPs are the most thoroughly automated plants of the world. In addition to the sweeping modernization strategies recommended by the plant manufacturers, based on computer-supported control, alternative modernization strategies have been considered in the evaluation process. This approach provides for room for maneuvre, for manufacturers as well as managers responsible for risk and cost optimization, which is a major task in view of the changing regulatory framework in the electricity market. (orig./CB) [de

  4. Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.

    Science.gov (United States)

    Erickson, S J; Fitzgerald, S W; Quinn, S F; Carrera, G F; Black, K P; Lawson, T L

    1992-05-01

    The tendon of the long head of the biceps muscle (long bicipital tendon) has a complex course from its muscle belly to its insertion onto the supraglenoid tubercle/glenoid labrum. It is stabilized by numerous tendinous and ligamentous structures and is, in turn, partly responsible for maintenance of normal glenohumeral function. In this report we describe the anatomy of this tendon, correlating high-resolution MR images with cryomicrotome sections. We illustrate typical MR findings in pathologic conditions affecting the long bicipital tendon sheath, the substance of the tendon, and finally the tendon position.

  5. Pseudo-reorganization of language cortical function at fMR imaging: a consequence of tumor-induced neurovascular uncoupling.

    Science.gov (United States)

    Ulmer, John L; Krouwer, Hendrikus G; Mueller, Wade M; Ugurel, M Sahin; Kocak, Mehmet; Mark, Leighton P

    2003-02-01

    A left-handed patient with a grade II left frontal lobe astrocytoma had spontaneous seizures causing speech arrest and uncontrolled right upper extremity movements. Word-generation functional MR (fMR) imaging showed activity nearly exclusively in the right inferior frontal gyrus. The clinical history of the speech arrest and the intraoperative mapping proved left-hemisphere language dominance. Tumor involvement of the left inferior frontal gyrus caused uncoupling of the blood oxygenation level-dependent (BOLD) and neuronal response, leading to the erroneous fMR imaging appearance of right-hemisphere language dominance. Discrepancies between BOLD and intraoperative mapping in areas near lesions illustrate the complementary nature of these techniques.

  6. Feasibility of MR urography in patients with urinary diversion

    International Nuclear Information System (INIS)

    Battal, Bilal; Kocaoglu, Murat; Ilica, Turan; Akgun, Veysel; Aydur, Emin; Dayanc, Murat

    2011-01-01

    The aims of this study were to determine the diagnostic value of MR urography and to compare the T2- and T1-weighted MR urography techniques in patients with urinary diversion. We retrospectively reviewed 19 MR urograms in 14 patients (13 male and one female, 8–77 years old, mean age: 54.2) with urinary diversion. Magnetic resonance urography examinations were performed with 1.5-T MR scanners. In addition to T2- and T1-weighted MR urography techniques, conventional T1- and T2-weighted axial and coronal sequences were also obtained. Collecting systems were evaluated in five segments (right proximal and distal collecting system, left proximal and distal collecting system and conduit or reservoir). Imaging features of the urinary collecting systems were evaluated with T2- and T1-weighted MR urography images. The clinical, laboratory data and follow-up imaging findings were regarded as standard. A cross table was formed to determine sensitivity, specificity and accuracy of MR urography techniques. T2-weighted MR urography, T1-weighted MR urography and combination of these two techniques could demonstrate 89.01, 87.65 and 93.83% of all collecting system segments, respectively. For the detection of the pathologic urinary segments, sensitivity, specificity and accuracy were 100, 95.29 and 95.6% in T2-weighted MR urography and 100, 93.42 and 93.82% in T1-weighted MR urography, respectively. Sensitivity, specificity and accuracy were 100% in combined T2- and T1-weighted MR urography technique. Magnetic resonance urography is an effective imaging method for the evaluation of the urinary system in patients with urinary diversion. T2-weighted MR urography alone has high sensitivity, specificity and accuracy, does not require intravenous contrast medium and can be obtained in 3–5 min. However, T1-weighted MR urography may provide additional information in some cases.

  7. Epstein-Barr virus encephalitis and encephalomyelitis: MR findings

    International Nuclear Information System (INIS)

    Shian, W.J.; Chi, C.S.

    1996-01-01

    The purpose of this project is to investigate the clinical and brain MR characteristics of Epstein-Barr virus (EBV) encephalitis and encephalomyelitis. Clinical and 30 MR findings of 29 patients with EBV encephalitis or encephalomyelitis were retrospectively reviewed. Patients included 24 with encephalitis, 3 with encephalomyelitis, and 2 with brain-stem encephalitis. Altered consciousness, seizures, visual hallucination, and acute psychotic reaction were the common presentations. Eight patients had positive MR findings. These included T2 prolongation over gray and white matter, periventricular leukomalacia, and brain atrophy. Transient T2 prolongation over gray and white matter was found in one patient. Our results indicate that EBV encephalitis and encephalomyelitis have a wide range of both clinical and MR findings. The MR lesions may disappear in a short period, so the timing for the MR scan may be critical. (orig.). With 5 figs., 2 tabs

  8. Epstein-Barr virus encephalitis and encephalomyelitis: MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Shian, W.J. [Department of Pediatrics, Tao-Yuan Veterans Hospital, No. 100, Sec 3, Cheng-Kung Rd, City of Tao-Yuan, Taiwan (Taiwan, Province of China); Chi, C.S. [Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan (Taiwan, Province of China)

    1996-09-01

    The purpose of this project is to investigate the clinical and brain MR characteristics of Epstein-Barr virus (EBV) encephalitis and encephalomyelitis. Clinical and 30 MR findings of 29 patients with EBV encephalitis or encephalomyelitis were retrospectively reviewed. Patients included 24 with encephalitis, 3 with encephalomyelitis, and 2 with brain-stem encephalitis. Altered consciousness, seizures, visual hallucination, and acute psychotic reaction were the common presentations. Eight patients had positive MR findings. These included T2 prolongation over gray and white matter, periventricular leukomalacia, and brain atrophy. Transient T2 prolongation over gray and white matter was found in one patient. Our results indicate that EBV encephalitis and encephalomyelitis have a wide range of both clinical and MR findings. The MR lesions may disappear in a short period, so the timing for the MR scan may be critical. (orig.). With 5 figs., 2 tabs.

  9. MR pancreatography (MRP) for mucin-producing pancreatic tumors

    International Nuclear Information System (INIS)

    Usuki, Noriaki; Nishimoto, Masaoki; Shima, Tomoko; Hirokawa, Keiko; Tashiro, Takahiko; Saiwai, Shigeo; Miyamoto, Takeshi; Okabe, Sumihiro

    1997-01-01

    MR pancreatography was performed in 11 patients with mucin-producing pancreatic tumor (main duct type: four and branch duct type: seven) using HASTE with a body phased array coil on a 1.5-T unit. The results of MR pancreatography were compared with imaging of endoscopic retrograde pancreatography (ERP). In all cases, MR pancreatography demonstrated all dilated pancreatic ducts and cysts. ERP did not completely demonstrate dilated ducts and cysts because of mucinous materials. Conspicuity of an intraductal tumor was more excellent by ER pancreatography than MR pancreatography. Therefore MR pancreatography and ER pancreatography are complementary methods in diagnosis for mucin-producing pancreatic tumors. (author)

  10. Cancer Metabolism and Tumor Heterogeneity: Imaging Perspectives Using MR Imaging and Spectroscopy

    Directory of Open Access Journals (Sweden)

    Gigin Lin

    2017-01-01

    Full Text Available Cancer cells reprogram their metabolism to maintain viability via genetic mutations and epigenetic alterations, expressing overall dynamic heterogeneity. The complex relaxation mechanisms of nuclear spins provide unique and convertible tissue contrasts, making magnetic resonance imaging (MRI and magnetic resonance spectroscopy (MRS pertinent imaging tools in both clinics and research. In this review, we summarized MR methods that visualize tumor characteristics and its metabolic phenotypes on an anatomical, microvascular, microstructural, microenvironmental, and metabolomics scale. The review will progress from the utilities of basic spin-relaxation contrasts in cancer imaging to more advanced imaging methods that measure tumor-distinctive parameters such as perfusion, water diffusion, magnetic susceptibility, oxygenation, acidosis, redox state, and cell death. Analytical methods to assess tumor heterogeneity are also reviewed in brief. Although the clinical utility of tumor heterogeneity from imaging is debatable, the quantification of tumor heterogeneity using functional and metabolic MR images with development of robust analytical methods and improved MR methods may offer more critical roles of tumor heterogeneity data in clinics. MRI/MRS can also provide insightful information on pharmacometabolomics, biomarker discovery, disease diagnosis and prognosis, and treatment response. With these future directions in mind, we anticipate the widespread utilization of these MR-based techniques in studying in vivo cancer biology to better address significant clinical needs.

  11. MR tomography in the assessment of functional stability of posterolateral lumbar fusions

    International Nuclear Information System (INIS)

    Lang, P.; Genant, H.K.; Chafetz, N.; Steiger, P.; Stoller, D.; California Univ., San Francisco

    1987-01-01

    MR tomography was used to assess functional lumbar stability in 30 patients with posterolateral fusions. The vertebral bodies of 9 of the 12 patients with unstable lumbar fusions presented with areas of decreased signal intensity on T 1 - and intermediately weighted images, which increased on T 2 -weighting. The vertebrae of 15 of the 18 patients with stable fusions demonstrated zones of increased signal intensity on T 1 - and intermediately weighted images, which were less intense or invisible on T 2 -weighting. Surgical correlation was available in 11 of the 30 patients studied. Hyperemia and inflammation appear to be responsible for the abnormal signal intensities in the patients with stable fusions, whereas an increase in adipose marrow due to decreased biomechanical stress is thought to account for the atypical signal intensities in the vertebral bodies of the patients with stable fusions. MR tomography seems to be a potential method for evaluating functional lumbar fusion stability. MR tomography may be particularly helpful in those patients with multiple back surgeries and possible instability, recurrent disc herniation, or post-operative fibrosis. MR is recommended in the patient, who appears clinically unstable, whose radiographs and CT, however, do not demonstrate fusion failure. (orig.) [de

  12. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  13. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  14. MR imaging of pineal cysts

    International Nuclear Information System (INIS)

    Ahn, Yong Sik; Yu, Hyeon; Kim, Wan Tae; Bae, Jin Woo; Moon, Hee Jung; Shin, Hyun Ja

    1999-01-01

    To evaluate the incidence and characteristic findings of pineal cyst incidentally detected on magnetic resonance (MR) imaging. Brain MR images obtained in 2432 patients were retrospectively reviewed to determine the incidence and MR findings of pineal cysts, which were evaluated according to their size, shape, location, signal intensity, interval change, contrast enhancement and mass effect on adjacent structures. Cysts were encountered in 107(4.4 %) of 2432 patients evaluated. their size ranged from 1 X 1 X 1 to 15 X 8 X 9 (mean, 5.97 X 3.82 X 4.82)mm. All were spherical (n=53) or oval (n=54) in shape. Their margin was smooth and they were homogeneous in nature. On T1-weighted images, the cysts were seen to be hyperintense (n=57) or isointense (n=50) to cerebrospinal fluid, but less so than brain parenchyma. T2-weighted images showed them to be isointense (n=51)or hyperintense (n=56) to cerebrospinal fluid. The cysts were centrally located in 65 cases and eccentrically in 42. Compression of the superior colliculi of the tectum was demonstrated in 17 cases (15.9 %). NO patients presented clinical symptoms or signs related to either pineal or tectal lesions. Peripheral enhancement around the cyst after Gd-DTPA injection was demonstrated in 51 cases(100 %). Follow-up examinations in 19 cases demonstrated no interval change. The incidence of pineal cysts was 4.4 %. The MR characteristics of simple pineal cysts include: (1) an oval or spherical shape, (2) a smooth outer margin and homogeneous nature, (3) isosignal or slightly high signal intensity to cerebrospinal fluid on whole pulse sequences, (4) ring enhancement after contrast injection, (5) an absence of interval change, as seen during follow up MR study. These MR appearances of pineal cysts might be helpful for differentiating them from pineal tumors

  15. MR findings of cerebral arteriovenous malformations associated with hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro (National Defence Medical Coll., Tokorozawa, Saitama (Japan))

    1990-10-01

    This study was developed to assess the role of magnetic resonance (MR) imaging in the diagnosis of cerebral arteriovenous malformations (AVMs) associated with hemorrhage. MR images were retrospectively reviewed in 10 patients (age 8 to 60 years) who had an AVM with intracerebral or intraventricular hemorrhage. MR imaging was performed at 1.5 T obtaining T{sub 1}- and T{sub 2}-weighted spin-echo images with a slice thickness of 5 mm, and a slice interval of 0-5 mm. The AVM was detected on MR in seven patients (70%), while enhanced CT was positive in six of eight patients (75%). In six patients in whom both the AVM and intracerebral hematoma (ICH) were depicted on MR, the nidi were located not inside but adjacent to the ICH. In three patients, MR disclosed a thin subdural hematoma (SDH) which was not noted on CT. There is little difference in the detectability of AVMs by MR and enhanced CT. However, MR clearly demonstrates the anatomic relationship to associated ICH. A non-traumatic SDH with an ICH demonstrated on MR may indicate the presence of an AVM even when the AVM itself is not apparent. (author).

  16. Utility of MR imaging in pediatric spinal cord injury

    International Nuclear Information System (INIS)

    Felsberg, G.J.; Tien, R.D.; Osumi, A.K.; Cardenas, C.A.

    1995-01-01

    We evaluated the utility of MR imaging in pediatric patients with acute and subacute spinal cord injuries. MR imaging of 22 pediatric patients with suspected traumatic spinal cord injuries was reviewed. MR findings were correlated with physical examination and compared to available radiographs and CT examinations performed at time of presentation. Twelve patients had abnormalities on MR imaging. Seven had spinal cord contusions; five contusions were hemorrhagic. Five of seven patients with cord contusion had normal radiographs and CT exams. Six patients with normal radiographs and CT examinations had abnormal MR studies revealing cord contusion, ligamentous injury, disc herniation, and epidural hematoma. MR is useful in initial evaluation of pediatric patients with spinal cord injuries and in prognosis of future neurologic function. In the setting of spinal cord symptomatology and negative radiographic studies, MR imaging should be performed. Surgically correctable causes of cord compression demonstrated by MR imaging include disc herniation, epidural hematoma, and retropulsed fracture fragments. The entity of spinal cord injury without radiographic abnormality is a diagnosis of exclusion which should only be made after radiologic investigation with radiographs, high-resolution thin-section CT, and MR imaging. (orig.)

  17. Interventional and intravascular MR angiography

    International Nuclear Information System (INIS)

    Ladd, M.E.; Debatin, J.F.

    2000-01-01

    Magnetic resonance imaging (MRI) has a number of characteristics which make it attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in any arbitrary oblique plane, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity and volume per unit time. For MR guidance of vascular interventions to be safe, catheters and guidewires must be visualized relative to the vascular system and surrounding tissues. A number of approaches for making instruments visible in an MR environment are presented, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts, whereas active techniques, including MR tracking, MR profiling, and active field inhomogeneity, use some form of electrical coil built into the instrument. The potential for obtaining high-resolution images of the vessel wall using coils built into a catheter is also discussed. These images provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications beyond those currently performed under X-ray fluoroscopic guidance. (orig.) [de

  18. MR diagnosis of temporomandibular arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Shigeaki [Kagoshima Univ. (Japan). Faculty of Dentistry

    1996-09-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author`s apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  19. MR diagnosis of temporomandibular arthrosis

    International Nuclear Information System (INIS)

    Suenaga, Shigeaki

    1996-01-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author's apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  20. TRANSFORMATION OF FAMILY IN MODERN RUSSIAN SOCIETY

    Directory of Open Access Journals (Sweden)

    Olga Anatolevna Otradnova

    2014-09-01

    Full Text Available The article examines concept of family in Russian society, changes in interpretation of family, connected with modern tendencies and processes in different sociocultural spheres.   The article is structured and has accurate limits of introduction, main part and conclusion. The relevance of the research is caused by present-day crisis tendencies connected with suicide actions, atomization and hedonization of society, value depreciation of family.  The object of the research is to analyze the conception of family and its transformation in condition of modern Russian society. The tasks are to determine the term family, to analyze approaches to understanding of the family and its genesis, detect some peculiarities of modern Russian society, research the transformation of interpretation of family in modern society; the matter of investigation is modern Russian society, the subject is the transformation of family structures; the following methods of research are used: historical and cultural approach, typological method, existential method, common logic procedures. The research contains author’s definition of the term family, historical and cultural analysis and typological explication of the approaches to interpretation of the problem, classification of family structures - which have been formed in Russian society- on the base of statistic and sociological data.   Some interweaving of concept family with the most important existential values (love, freedom, responsibility were investigated and some tendencies for further development of family relationship in Russian society were revealed, its problems and prospect were emphasized. The results of the investigation testify that modern types of matrimonial relationship differ in limitation of functionality, mutual responsibility, thereby it is possible to state that interpretation of family in modern Russian society has transformed.

  1. Cardiac and vascular imaging with snapshot FLASH MR imaging

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Norris, D.; Leibfritz, D.; Henrich, D.; Duhmke, E.

    1989-01-01

    Acceleration of fast low-angle-shot (FLASH) MR imaging to about 200 msec measuring time on dedicated MR systems is called snapshot FLASH MR imaging. It snaps real-time series of MR images of the MR relaxation and of physiologic motions with nearly absent motion and susceptibility artifacts. Results in animals (4.7T) and human volunteers (2.0T) show plain vascular and cardiac snapshot FLASH MR images obtained as single shot, triggered reconstructed motion, or real-time films. The reduction of artifacts and the high resolution (triggered, three-dimensional moving heart images are possible) result in favorable applications in myocardial and great vascular disease

  2. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Cherry, Simon R

    2006-12-01

    PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

  3. MR imaging in hemophilic arthropathy

    International Nuclear Information System (INIS)

    Baunin, C.; Railhac, J.J.; Younes, I.; Gaubert, J.; DuBoullay, C.; Dirat, G.; Robert, A.

    1990-01-01

    This paper reports on twenty children with hemophilia examined to determine if MR imaging could be used to assess hemophilic arthropathy. Twenty-eight joints were imaged (17 knees, 10 ankles, 1 elbow) with plain radiography, US, CT, and MR imaging. The results were compared with the surgical view and histologic study of the articular components when synovectomy was done. These results show the usefulness of MR imaging: fluid collections in the joint space were evaluated, and it was possible to distinguish blood from inflammatory fluid. Synovial hypertrophy was appreciated, and findings correlated well with histologic study. Anomalies of articular cartilage, joint-space narrowing, and bone lesions were demonstrated early, when plain radiography findings were still normal

  4. Retroperitoneal fibrosis: findings with MR

    International Nuclear Information System (INIS)

    Martinez Rodrigo, J.; Marti-Bonnati, L.; Diago, T.; Ferrer, M.D.; Aleixandre, A.; Morote, V.

    1993-01-01

    Retroperitoneal fibrosis (RF) is an uncommon disease characterized by the presence of a chronic inflammatory reaction, with the formation of fibrous tissue that replaces the normal retroperitoneal tissue, trapping vessels and/or ureters. We present a retrospective review of 3 cases of idiopathic RF studied by means of ultrasound, CT scan and MR imaging, and we assess the features of the MR image, as well as its capacity for characterizing the lesion. We compare the findings obtained with 3 imaging techniques, describing the utility of each one, and their advantages and disadvantages in the assessment of this pathology. In MR, idiopathic RF appears as a hypodense mass in SET1, SE-T2 and STIR sequences. (Author) 9 ref

  5. Valuation of dynamic MR imaging for diagnosis of pituitary microadenomas

    International Nuclear Information System (INIS)

    Lu Wu; Zhou Shengli; Liu Yusheng

    2003-01-01

    Objective: To evaluate the use of keyhole dynamic magnetic resonance (MR) imaging in evaluation of pituitary microadenomas. Methods: Fifty-three patients with pituitary microadenomas proved by operation or clinical findings such as headache, amenorrhea, lactating, fat or acromegaly were retrospectively studied on dynamic MR, conventional contrast enhanced MR, and unenhanced MR. Then the image data were analyzed by two experienced doctors who didn't know the details and three degrees were made as follows: grade 0, no evidence of the tumor; grade I, asymmetry signals in the pituitary; and grade II, nodulated or sheets signals in the pituitary. The grading data were compared with statistical methods. Results: In dynamic MR grading system: grade 0 was revealed in 1 patient, grade I in 29 patients and grade II in 23 patients. In conventional enhanced MR: grade 0 in 26 patients, grade I in 17 patients and grade II in 10 patients. In conventional unenhanced MR: grade 0 in 39 patients, grade I in 10 patients and grade II in 4 patients. The diagnostic rate of dynamic MR, conventional enhanced MR, and unenhanced MR was 98.1%, 51.9%, and 26.4%, respectively. (P < 0.005). Dynamic MR can increase the grade of tumor compared to the other two, which is significant statistically. Conclusion: Keyhole dynamic MR can increase the diagnostic accuracy of pituitary microadenomas while decreasing the uncertainty. So dynamic MR should become a routine examination for pituitary microadenoma when suspected by clinical findings but negative in conventional MR

  6. Experimental validation of hyperthermia SAR treatment planning using MR B1+ imaging

    International Nuclear Information System (INIS)

    Berg, Cornelis A T van den; Bartels, Lambertus W; Leeuw, Astrid A C De; Lagendijk, Jan J W; Kamer, Jeroen B Van de

    2004-01-01

    In this paper the concept of using B 1+ imaging as a means to validate SAR models for radiofrequency hyperthermia is presented. As in radiofrequency hyperthermia, in common clinical MR imaging which applies RF frequencies between 64 and 128 MHz, the RF field distribution inside a patient is largely determined by the dielectric distribution of the anatomy. Modern MR imaging techniques allow measurement of the RF magnetic field component B 1+ making it possible to measure at high resolution the dielectric interaction of the RF field with the patient. Given these considerations, we propose to use MR imaging to verify the validity of our dielectric patient model used for SAR models of radiofrequency hyperthermia. The aim of this study was to investigate the feasibility of this concept by performing B 1+ measurements and simulations on cylindrical split phantoms consisting of materials with dielectric properties similar to human tissue types. Important topics of investigation were the accuracy and sensitivity of B 1+ measurements and the validity of the electric model of the MR body coil. The measurements were performed on a clinical 1.5 T MR scanner with its quadrature body coil operating at 64 MHz. It was shown that even small B 1+ variations of 2 to 5% could be measured reliably in the phantom experiments. An electrical model of the transmit coil was implemented on our FDTD-based hyperthermia treatment planning platform and the RF field distributions were calculated assuming an idealized quadrature current distribution in the coil. A quantitatively good correlation between measurements and simulations was found for phantoms consisting of water and oil, while highly conductive phantoms show considerable deviations. However, assuming linear excitation for these conductive phantoms resulted in good correspondence. As an explanation it is suggested that the coil is being detuned due to the inductive nature of the conductive phantoms, breaking up the phase difference of

  7. Multiparametric MR assessment of pediatric brain tumors

    International Nuclear Information System (INIS)

    Tzika, A.A.; Astrakas, L.G.; Zarifi, M.K.; Petridou, N.; Young-Poussaint, T.; Goumnerova, L.; Black, P.McL.; Zurakowski, D.; Anthony, D.C.

    2003-01-01

    MR assessment of pediatric brain tumors has expanded to include physiologic information related to cellular metabolites, hemodynamic and diffusion parameters. The purpose of this study was to investigate the relationship between MR and proton MR spectroscopic imaging in children with primary brain tumors. Twenty-one patients (mean age 9 years) with histologically verified brain tumors underwent conventional MR imaging, hemodynamic MR imaging (HMRI) and proton MR spectroscopic imaging (MRSI). Fourteen patients also had diffusion-weighted MR imaging (DWMRI). Metabolic indices including choline-containing compounds (Cho), total creatine (tCr) and lipids/lactate (L) were derived by proton MRSI, relative cerebral blood volume (rCBV) by HMRI, and apparent tissue water diffusion coefficients (ADC) by DWMRI. Variables were examined by linear regression and correlation as well as by ANOVA. Cho (suggestive of tumor cellularity and proliferative activity) correlated positively with rCBV, while the relationship between Cho and ADC (suggestive of cellular density) was inverse (P<0.001). The relationship between rCBV and ADC was also inverse (P=0.004). Cho and lipids (suggestive of necrosis and/or apoptosis) were not significantly correlated (P=0.51). A positive relationship was found between lipids and ADC (P=0.002). The relationships between Cho, rCBV, ADC and lipids signify that tumor physiology is influenced by the tumor's physical and chemical environment. Normalized Cho and lipids distinguished high-grade from low-grade tumors (P<0.05). Multiparametric MR imaging using MRSI, HMRI and DWMRI enhances assessment of brain tumors in children and improves our understanding of tumor physiology while promising to distinguish higher- from lower-malignancy tumors, a distinction that is particularly clinically important among inoperable tumors. (orig.)

  8. MR imaging of an intrapericardial pheochromocytoma

    International Nuclear Information System (INIS)

    Fisher, M.R.; Higgins, C.B.; Andereck, W.

    1985-01-01

    The magnetic resonance (MR) appearance of an intrapericardial pheochromocytoma is reported, and the role of MR, compared with CT and a 131 I-metaiodobenzylguanidine scan in delineating masses from cardiac and vascular structures in the mediastinum is discussed

  9. MR findings of bowlegs in toddlers

    International Nuclear Information System (INIS)

    Iwasawa, Tae; Inaba, Yutaka; Kameshita, Kikuo; Nishimura, Gen; Aida, Noriko; Matsubara, Sho

    1999-01-01

    Background. Toddlers with severe physiologic tibial bowing are considered to be at risk for the development of Blount's disease. Objective. To correlate MR findings of the knee with the clinical outcome in toddlers with severe physiological tibial bowing. Materials and methods. MR findings were evaluated in 22 affected legs of 14 children with severe tibial bowing (mean age 1.9 years). In 18 affected legs, MR findings were compared with the transition of the tibial metaphyseal-diaphyseal angle (MDA) and tibiofemoral angle (TFA) measured serially between 2 and 3 years of age. Results. MR findings of severe tibial bowing comprised undulation of the posteromedial physis of the tibia (3/22), signal alterations in the medial tibial metaphysis (10/22), T2 prolongation in the posteromedial tibial epiphyseal cartilage (14/22) and signal changes in the medial menisci (18/22). The decrease in the TFA was different in the legs with and without increased signal in the epiphyseal cartilage, and the decrease in the MDA was different in the legs with and without physeal undulation. Conclusion. MR imaging findings can predict the retarded resolution of tibial bowing, which may be a risk factor for the development of Blount's disease. (orig.)

  10. Nontraumatic spinal epidural hematomas. MR features

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Baumgartner, R.W.; Zambaz, B.D.; Remonda, L.; Ozdoba, C.; Schroth, G.

    1997-01-01

    Purpose: Spinal epidural hematoma (SEH) is a rare clinical entity with a bleak outcome. The aim of our study was to establish the value of MR findings in the diagnosis of nontraumatic SEH. Material and Methods: Seven patients with nontraumatic SEH were examined by MR at 1.5 T. Two patients were under anticoagulation therapy with heparin, and 2 others were taking salicylic acid. One patient had lupus erythematodes with a marked thrombocytopenia. One patient had a spinal arteriovenous malformation. Results: MR imaging permitted the accurate localization of extradural intraspinal expansive lesions which exhibited the characteristic signal intensities of blood. Five patients underwent laminectomy and evacuation of the hematoma. In the acute phase, the hematomas appeared isointense when compared with the spinal cord on T1-weighted images and hyperintense on T2-weighted images. Later the hematomas were hyperintense on T1-weighted images and showed signals identical to those of cerebrospinal fluid (CSF) on T2-weighted images. Conclusion: MR imaging established the exact diagnosis and localization of SEH in all cases. MR also can provide useful information about the age of the hematomas. (orig.)

  11. MR imaging and histopathology of cartilage tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mizutani, Hirokazu; Ohba, Satoru; Ohtsuka, Takanobu; Matui, Norio; Nakamura, Takaaki (Nagoya City Univ. (Japan). Faculty of Medicine)

    1994-05-01

    The MR imaging-pathologic correlation of cartilaginous bone tumors and the value of intravenously administered Gd-DTPA enhanced MR imaging was studied. The MR studies were retrospectively reviewed. Thirty-seven cases were examined with 0.5 T and 1.0 T scanner and all cases were pathologically proved. We discussed the following MR findings: signal intensities of tumors, Gd-DTPA features, morphological findings, and associated findings. Hyaline cartilage tumors showed low signal intensity on T[sub 1]-weighted images and very high signal intensity on T[sub 2]-weighted images. Lobulated marginal enhancements were recognized in chondrosarcomas. This may be an important finding to suspect chondrosarcoma. (author).

  12. MR angiography of eddy-current-free MR imaging system with a 3T permanent magnet

    International Nuclear Information System (INIS)

    Nishimura, H.; Watanabe, S.; Takeuchi, H.

    1991-01-01

    This paper reports that, the authors main purpose was to evaluate two-dimensional time flight MR angiography in the visualization of vascular structure by using an eddy-current-free 0.3-T permanent magnet MR imaging system. The authors have developed multisection acquisition technique for two-dimensional time-of-flight MR angiography with the use of velocity-compensated gradient echoes. MR angiograms were obtained with a ray-tracing algorithm of the new modified maximum intensity projection at various viewing angles. These angiograms are displayed on cathode-ray tubes in a high-speed cyclic mode to depict the front-rear relation of vessels for better recognition. With an eddy-current-free permanent magnet system, two-dimensional time-of-flight angiography could clearly depict intracranial vascular structure, cervical vessels, and vessels of the extremities with thin-section (2 or 3 mm) acquisition. A high flip angle (90 degrees) with a short TR enabled better differentiation between blood flow and stationary tissues. Stenosis of the carotids could be detected in accordance with digital subtraction angiography

  13. Magnetic resonance imaging of sacroiliitis: anatomy, histological pathology, MR-morphology, and grading; Magnetresonanztomographie der Sakroiliitis: Anatomie, Pathohistologie, MR-Morphologie und Graduierung

    Energy Technology Data Exchange (ETDEWEB)

    Hermann, K.G.A.; Fischer, T. [Institut fuer Radiologie, Charite Universitaetsmedizin Berlin (Germany); Braun, J. [Rheumazentrum Ruhrgebiet, St. Josefs-Krankenhaus, Herne (Germany); Reisshauer, H. [Gemeinschaftspraxis fuer Pathologie, Neubrandenburg (Germany); Bollow, M. [Institut fuer Radiologie, Augusta-Kranken-Anstalt, Bochum (Germany)

    2004-03-01

    The diagnosis of spondyloarthropathy is based on radiography of the sacroiliac joints, beside the patient's history and clinical examination. In cases where the clinical examination and radiography yield discrepant findings, contrast-enhanced magnetic resonance imaging (MRI) is a sensitive modality for the diagnosis of early sacroiliitis. Knowledge of the morphologic anatomy of the sacroiliac joints and of their abnormal micro- and macroanatomy in sacroiliitis and enthesitis are helpful for interpreting MR images. Arthritis of the sacroiliac joints is characterized by subchondral sclerosis, erosions, transarticular bone bridges, accumulation of periarticular fat, juxta-articular osteitis, synovitis, capsulitis, and enthesitis. The major histologic finding in active sacroiliitis is the presence of proliferative, pannus-like connective tissue destroying cartilage and bone. This tissue contains fibroblasts and fibrocytes as well as T cells and macrophages with a shift of the CD4/CD8 ratio toward the CD4 T helper cell population. The well-established grading of MRI findings by means of a chronicity and activity index, which are determined quantitatively from dynamic MR images, is supplemented by an alternative, semiquantitative grading of activity. The following grades were defined for the short tau inversion recovery (STIR) sequence or the T1-weighted, fat-saturated spin-echo sequence for each quadrant (iliac anterior, iliac posterior, sacral anterior, sacral posterior):0: no signal increase,1: local signal increase in the joint cavity or within erosions,2: small areas of increased juxta-articular signal,3: moderate sized areas of increased juxta-articular signal,4: large areas of increased juxta-articular signal.Values of the 4 quadrants are summed to an activity score (range 0-16). The new grading system is proposed to facilitate the examination and shorten image interpretation time. (orig.) [German] Neben Anamnese und klinischer Untersuchung bildet das

  14. Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy

    Science.gov (United States)

    Wyatt, Jonathan J.; Dowling, Jason A.; Kelly, Charles G.; McKenna, Jill; Johnstone, Emily; Speight, Richard; Henry, Ann; Greer, Peter B.; McCallum, Hazel M.

    2017-12-01

    There is increasing interest in MR-only radiotherapy planning since it provides superb soft-tissue contrast without the registration uncertainties inherent in a CT-MR registration. However, MR images cannot readily provide the electron density information necessary for radiotherapy dose calculation. An algorithm which generates synthetic CTs for dose calculations from MR images of the prostate using an atlas of 3 T MR images has been previously reported by two of the authors. This paper aimed to evaluate this algorithm using MR data acquired at a different field strength and a different centre to the algorithm atlas. Twenty-one prostate patients received planning 1.5 T MR and CT scans with routine immobilisation devices on a flat-top couch set-up using external lasers. The MR receive coils were supported by a coil bridge. Synthetic CTs were generated from the planning MR images with (sCT1V ) and without (sCT) a one voxel body contour expansion included in the algorithm. This was to test whether this expansion was required for 1.5 T images. Both synthetic CTs were rigidly registered to the planning CT (pCT). A 6 MV volumetric modulated arc therapy plan was created on the pCT and recalculated on the sCT and sCT1V . The synthetic CTs’ dose distributions were compared to the dose distribution calculated on the pCT. The percentage dose difference at isocentre without the body contour expansion (sCT-pCT) was Δ D_sCT=(0.9 +/- 0.8) % and with (sCT1V -pCT) was Δ D_sCT1V=(-0.7 +/- 0.7) % (mean  ±  one standard deviation). The sCT1V result was within one standard deviation of zero and agreed with the result reported previously using 3 T MR data. The sCT dose difference only agreed within two standard deviations. The mean  ±  one standard deviation gamma pass rate was Γ_sCT = 96.1 +/- 2.9 % for the sCT and Γ_sCT1V = 98.8 +/- 0.5 % for the sCT1V (with 2% global dose difference and 2~mm distance to agreement gamma criteria). The one voxel body contour

  15. MR imaging in cervical hyperextension injuries

    International Nuclear Information System (INIS)

    Davis, S.J.; Teresi, L.M.; Bradley, W.G. Jr.; Ziemba, M.R.

    1990-01-01

    This paper reports on cervical hyperextension injuries that are common and often show minimal radiographic abnormalities, even with severe or unstable lesions. MR images and clinical records of 14 patients scanned within 4 months of hyperextension cervical injuries were reviewed. Clinical, radiographic, and MR findings were correlated. Nine patients had acceleration hyperextension whiplash injuries, four with acute cervical disk herniations developing radiculopathy after several weeks. Five patients injured by direct frontal head trauma presented with myelopathy and had MR evidence of cord injury, and four had acute disk herniation

  16. MR imaging and spinal cord injury

    International Nuclear Information System (INIS)

    Azar-Kia, B.; Fine, M.; Naheedy, M.; Elias, D.

    1987-01-01

    MR imaging has significantly improved diagnostic capability of spinal cord injuries. Other available diagnostic modalities such as plain films, myelography, CT, and post-CT myelography have failed to consistently show the secific evidence of spinal cord injuries and their true extent. The authors are presenting our experiences with MR imaging in spinal column injury. They have found MR imaging to be the procedure of choice for prognostic evaluation of spinal cord trauma. They are showing examples of recent and old spinal cord injury such as hematomyelia, myelomalacia, transection, spinal cord edema, and cavitation

  17. MR imaging of heterotopic gray matter

    International Nuclear Information System (INIS)

    Kryst-Widzgowska, T.; Kozlowski, P.; Poniatowska, R.

    1994-01-01

    Six patients with heterotopic gray matter were evaluated with MR. 5 patients had history of seizures. 4 cases were suspected of the cerebral tumor. In the MR examination areas of heterotopic gray matter were found along the posterior horn of the lateral ventricle on the one side in 4 cases and bilateraly in 2 cases. In 3 cases another brain abnormalities were also detected including: hypoplasia of corpus callosum, hypoplasia of brain hemisphere, cavum septi pellucidi. MR is a modality of choice in the assessment of abnormal gray matter migration. (author)

  18. MR in plasmocytoma

    International Nuclear Information System (INIS)

    Linden, A.; Widder, R.; Jungehuelsing, M.; Schicha, H.; Gueckel, C.; Diehl, V.

    1992-01-01

    In 20 patients with multiple myeloma, the results of MR, X-ray, bone scintigraphy, bone marrow scintigraphy and bone marrow biopsy were compared. MR proved the most sensitive imaging method for the detection of bone marrow infiltration followed by X-ray examinations. Bone marrow scintigraphy and especially bone scintigraphy revealed false negative results more often. These findings were more impressive by the direct comparison of several investigated regions showing different findings of each imaging method. False positive results were not found. In 4 patients false negative results of bone marrow biopsy had to be assumed because of definitely pathological findings by X-ray and MRI. (orig.) [de

  19. Mr Bjarne Mork-Eidem, Director General, Norwegian State Audit

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Photos 01,02: Mr Bjarne Mørk-Eidem, Auditor General of Norway (centre) visiting the ATLAS assembly hall in building 180, with from left to right: Prof. Steinar Stapnes, University of Oslo ; Mr Per Ivar Lied, Permanent Mission of Norway, Geneva ; Prof. Egil Lillestøl, University of Bergen and Mr Jan Otto Jøranli, Office of the Auditor General of Norway, May 2003. Photo 03: Mr Bjarne Mørk-Eidem, Auditor General of Norway (left) visiting the ATLAS assembly hall in building 180, with from left to right: Mr Jan Otto Jøranli, Office of the Auditor General of Norway ; Prof. Steinar Stapnes, University of Oslo and Prof. Egil Lillestøl, University of Bergen, May 2003. Photo 04: Mr Bjarne Mørk-Eidem, Auditor General of Norway, during his visit of the ATLAS assembly hall in building 180, May 2003. Photo 05: From left to right: Mr Jan Otto Jøranli, Office of the Auditor General of Norway ; Mr Bjarne Mørk-Eidem, Auditor General of Norway; Prof. Egil Lillestøl, University of Bergen and Prof. Steinar Stapnes, Univ...

  20. MR imaging and MR spectroscopy for characterization of cardiomyopathies in adolescents - preliminary results

    International Nuclear Information System (INIS)

    Beer, M.; Buchner, S.; Fuchs, J.; Machann, W.; Ritter, C.O.; Beissert, M.; Darge, K.; Hahn, D.; Koestler, H.; Wirbelauer, J.

    2007-01-01

    Purpose: Cardiomyopathy is a rare but life-threatening disease in children and adolescents. Recent studies reported morphological, functional or metabolic alterations of the heart. We discuss a combined MR imaging and 31 P MR spectroscopy (MRS) protocol allowing the analysis of interdependencies between these parameters. Since normal values of cardiac MR parameters in this age group are not available, we included studies of age-matched healthy adolescents. Materials and Methods: 2D-CINE was used to assess left ventricular (LV) parameters. Additional 3D-Chemical Shift Imaging (3D-CSI) and Spectral Localization with Optimal Pointspread Function (SLOOP) reconstruction allowed quantification of the cardiac energy metabolism. Patients (n = 4; all male; age 16.8 ± 2.9 years) were included on the basis of an echocardiographic diagnosis of possible cardiomyopathy. The same protocol was applied to healthy young volunteers (n = 4; 1 female, 3 male; age 15.5 ± 0.6 years). Results: The patients had a significantly higher LV mass index compared to the control group (147 ± 41 g/m2 versus 97 ± 16 g/m2; p = 0.04). The other LV parameters (including LV EF with 59 ± 22 % versus 67 ± 10 %) showed no significant differences. The phosphocreatine to adenosine triphosphate ratio (PCr/ATP-ratio) of the patients was reduced to 1.71 ± 0.40 versus 2.44 ± 0.30 (p = 0.01), combined with a tendency towards decreased PCr concentrations of 9.1 ± 2.5 versus 7.9 ± 1.0 mmol/kg. Conclusion: The combination of 31 P MR spectroscopy and MR imaging allows quantitative determination of morphologic, functional and metabolic alterations in adolescents with suspected cardiomyopathy in one examination procedure. The reduction of energy metabolism combined with unaltered global function may indicate a primary role of metabolism in the pathogenesis of cardiomyopathies in adolescents. (orig.)

  1. Gd-DTPA administered MR imaging of intracranial mass lesions

    International Nuclear Information System (INIS)

    Mihara, Futoshi; Hirakata, Ryosuke; Hasuo, Kanehiro; Yasumori, Kotaro; Yoshida, Kisaku; Kuroiwa, Toshiro; Masuda, Kouji; Fukui, Masashi

    1989-01-01

    Magnetic resonance (MR) images of 13 intracranial mass lesions taken with the intravenous administration of gadolinium-DTPA were evaluated in comparison with precontrast computed tomography (CT), postcontrast CT, and precontrast MR. In the MR images taken with Gd-DTPA, tumor delineation improved in eight of 13 cases (62%) in comparison with precontrast MR images, and in seven of 13 cases (54%) in comparison with the overall evaluation of precontrast CT, postcontrast CT, and precontrast MR images. Tumor demarcation was unchanged in the remaining cases; no deterioration was observed with Gd-DTPA administration. MR imaging with Gd-DTPA should be performed to better evaluate the extent of intracranial mass lesions and to provide additional information. (author)

  2. An investigation of Saudi Arabian MR radiographers' knowledge and confidence in relation to MR image-quality-related errors

    International Nuclear Information System (INIS)

    Alsharif, W.; Davis, M.; McGee, A.; Rainford, L.

    2017-01-01

    Objective: To investigate MR radiographers' current knowledge base and confidence level in relation to quality-related errors within MR images. Method: Thirty-five MR radiographers within 16 MRI departments in the Kingdom of Saudi Arabia (KSA) independently reviewed a prepared set of 25 MR images, naming the error, specifying the error-correction strategy, scoring how confident they were in recognising this error and suggesting a correction strategy by using a scale of 1–100. The datasets were obtained from MRI departments in the KSA to represent the range of images which depicted excellent, acceptable and poor image quality. Results: The findings demonstrated a low level of radiographer knowledge in identifying the type of quality errors and when suggesting an appropriate strategy to rectify those errors. The findings show that only (n = 7) 20% of the radiographers could correctly name what the quality errors were in 70% of the dataset, and none of the radiographers correctly specified the error-correction strategy in more than 68% of the MR datasets. The confidence level of radiography participants in their ability to state the type of image quality errors was significantly different (p < 0.001) for who work in different hospital types. Conclusion: The findings of this study suggest there is a need to establish a national association for MR radiographers to monitor training and the development of postgraduate MRI education in Saudi Arabia to improve the current status of the MR radiographers' knowledge and direct high quality service delivery. - Highlights: • MR radiographers recognised the existence of the image quality related errors. • A few MR radiographers were able to correctly identify which image quality errors were being shown. • None of MR radiographers were able to correctly specify error-correction strategy of the image quality errors. • A low level of knowledge was demonstrated in identifying and rectify image quality errors.

  3. Multiple modernities, modern subjectivities and social order

    DEFF Research Database (Denmark)

    Jung, Dietrich; Sinclair, Kirstine

    2015-01-01

    to modern subjectivity formation. In combining conceptual tools from these strands of social theory, we argue that the emergence of multiple modernities should be understood as a historical result of idiosyncratic social constructions combining global social imaginaries with religious and other cultural......Taking its point of departure in the conceptual debate about modernities in the plural, this article presents a heuristic framework based on an interpretative approach to modernity. The article draws on theories of multiple modernities, successive modernities and poststructuralist approaches...... traditions. In the second part of the article we illustrate this argument with three short excursions into the history of Islamic reform in the 19th and 20th centuries. In this way we interpret the modern history of Muslim societies as based on cultural conflicts between different forms of social order...

  4. Pseudodynamic MR imaging of temporomandibular joint disorders

    International Nuclear Information System (INIS)

    Nakasato, Tatsuhiko; Ehara, Shigeru

    1992-01-01

    Magnetic resonance (MR) imaging of the temporomandibular joint (TMJ) has now been established as a procedure of choice in the evaluation of TMJ disorders. In this study, we evaluated the dynamics of TMJ motion on MR imaging, which resembles arthrography. Sixty-eight TMJs in 38 symptomatic patients and one healthy volunteer were examined using pseudodynamic images with gradient echo sequences using a 0.5 Tesla MR unit and 8 cm circular planar surface coil. For depiction of each compartment of the meniscus, the optimum sequence was 200/15/2 (TR/TE/excitations) with 50 deg or 60 deg flip angle in gradient refocused acquisition in steady-state (GRASS) sequences. Three contiguous slices on sagittal MR images were routinely obtained at 14-18 different phases of the opening cycle and displayed in closed-loop cine fashion. Internal derangement was observed in 57% of 68 joints. The most common type was anterior meniscal displacement without reduction. Sideway and rotational displacements, observed in 10% each, were noted on both sagittal multislice images and axial reference images. As a pseudodynamic MR technique, jaw movement specifically designed to check bite procedure to adjust splints is useful for detecting the exact time of meniscal redisplacement on the second click. After conservative therapy for arthrosis, pseudodynamic MR provided information on changes in the meniscus and condylar relationship. Pseudodynamic MR with multiple phases is suitable for evaluating subtle motion abnormality of the meniscus and for post-therapeutic monitoring. (author)

  5. Pseudodynamic MR imaging of temporomandibular joint disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Tatsuhiko; Ehara, Shigeru (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1992-09-01

    Magnetic resonance (MR) imaging of the temporomandibular joint (TMJ) has now been established as a procedure of choice in the evaluation of TMJ disorders. In this study, we evaluated the dynamics of TMJ motion on MR imaging, which resembles arthrography. Sixty-eight TMJs in 38 symptomatic patients and one healthy volunteer were examined using pseudodynamic images with gradient echo sequences using a 0.5 Tesla MR unit and 8 cm circular planar surface coil. For depiction of each compartment of the meniscus, the optimum sequence was 200/15/2 (TR/TE/excitations) with 50 deg or 60 deg flip angle in gradient refocused acquisition in steady-state (GRASS) sequences. Three contiguous slices on sagittal MR images were routinely obtained at 14-18 different phases of the opening cycle and displayed in closed-loop cine fashion. Internal derangement was observed in 57% of 68 joints. The most common type was anterior meniscal displacement without reduction. Sideway and rotational displacements, observed in 10% each, were noted on both sagittal multislice images and axial reference images. As a pseudodynamic MR technique, jaw movement specifically designed to check bite procedure to adjust splints is useful for detecting the exact time of meniscal redisplacement on the second click. After conservative therapy for arthrosis, pseudodynamic MR provided information on changes in the meniscus and condylar relationship. Pseudodynamic MR with multiple phases is suitable for evaluating subtle motion abnormality of the meniscus and for post-therapeutic monitoring. (author).

  6. Role of magnetic resonance imaging (MRI), MR spectroscopy (MRS) and other imaging modalities in breast cancer

    International Nuclear Information System (INIS)

    Sharma, Uma; Virendra Kumar; Jagannathan, N.R.

    2004-01-01

    Breast cancer is the commonest cancer among women world over and the diagnosis continues to generate fear and turmoil in the life of patients and their families. This article describes the currently available techniques used for screening primary and recurrent breast cancers and the evaluation of therapeutic response of breast cancer with special emphasis on MRI and MRS techniques. MRI, a noninvasive technique, provides anatomic images in multiple planes enabling tissue characterization. Contrast enhanced MR studies have been found to be useful in the diagnosis of small tumors in dense breast benign diseases from malignant ones. In vivo magnetic resonance spectroscopy (MRS) is another useful technique for diagnosis and for assessing the biochemical status of normal and diseased tissues. Being noninvasive, MR techniques can be used repetitively for assessment of response of the tumor to various therapeutic regimens and for evaluating the efficacy of drugs at both the structural and molecular level. An overview of the various aspects of different imaging modalities used in breast cancer research including various in vivo MR methodologies with clinical examples is presented in this review. (author)

  7. Modernity: Are Modern Times Different?

    Directory of Open Access Journals (Sweden)

    Lynn Hunt

    2014-12-01

    Full Text Available “Modernity” has recently been the subject of considerable discussion among historians. This article reviews some of the debates and argues that modernity is a problematic concept because it implies a complete rupture with “traditional” ways of life. Studies of key terms are undertaken with the aid of Google Ngrams. These show that “modernity,” “modern times,” and “traditional” —in English and other languages— have a history of their own. A brief analysis of the shift from a self oriented toward equilibrium to a self oriented toward stimulation demonstrates that modernity is not necessary to historical analysis.

  8. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  9. Traumatic spinal cord injury in MR imaging; Urazowe przerwanie ciaglosci rdzenia kregowego w obrazie MR

    Energy Technology Data Exchange (ETDEWEB)

    Bronarski, J.; Wozniak, E. [Stoleczne Centrum Rehabilitacji, Konstancin (Poland)]|[Inst. Psychiatrii i Neurologii, Warsaw (Poland)

    1993-12-31

    Spinal cord injuries in tetraplegics were briefly discussed on the basis of MR imaging. It was found that severe cervical spine trauma usually results in concussion - the complete transection of the cord is rare. A case of 19 years old male with total cord transection confirmed by MR imaging is described. (author). 5 refs, 3 figs.

  10. WE-H-207B-02: MR-Driven RT Planning

    Energy Technology Data Exchange (ETDEWEB)

    Cao, M. [UCLA School of Medicine (United States)

    2016-06-15

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

  11. WE-H-207B-02: MR-Driven RT Planning

    International Nuclear Information System (INIS)

    Cao, M.

    2016-01-01

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A

  12. MR arthrography of the shoulder: possible indications for clinical use

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Grebe, P.; Kersjes, W.; Runkel, M.; Kirschner, P.; Schild, H.H.

    1994-01-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [de

  13. Prenatal MR imaging of congenital diaphragmatic hernias: association of MR fetal lung volume with the need for postnatal prosthetic patch repair

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, Claudia; Weidner, Meike; Schoenberg, Stefan O.; Buesing, Karen A.; Neff, K.W. [University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim (Germany); Zahn, Katrin [University of Heidelberg, Department of Pediatric Surgery, University Medical Center Mannheim, Mannheim (Germany); Weiss, Christel [University of Heidelberg, Department of Medical Statistics and Biomathematics, University Medical Center Mannheim, Mannheim (Germany); Schaible, Thomas [University of Heidelberg, Department of Pediatrics, University Medical Center Mannheim, Mannheim (Germany)

    2015-01-15

    To assess whether the need for postnatal prosthetic patch repair of the diaphragmatic defect in neonates with a congenital diaphragmatic hernia (CDH) is associated with the antenatal measured observed-to-expected magnetic resonance fetal lung volume (o/e MR-FLV). The o/e MR-FLV was calculated in 247 fetuses with isolated CDH. Logistic regression analysis was used to assess the prognostic value of the individual o/e MR-FLV for association with the need for postnatal patch repair. Seventy-seven percent (77 %) of patients with a CDH (190/247) required prosthetic patch repair and the defect was closed primarily in 23 % (57/247). Patients requiring a patch had a significantly lower o/e MR-FLV (27.7 ± 10.2 %) than patients with primary repair (40.8 ± 13.8 %, p < 0.001, AUC = 0.786). With an o/e MR-FLV of 20 %, 92 % of the patients required patch repair, compared to only 24 % with an o/e MR-FLV of 60 %. The need for a prosthetic patch was further influenced by the fetal liver position (herniation/no herniation) as determined by magnetic resonance imaging (MRI; p < 0.001). Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy (AUC = 0.827). Logistic regression analysis based on the o/e MR-FLV is useful for prenatal estimation of the prosthetic patch requirement in patients with a CDH. In addition to the o/e MR-FLV, the position of the liver as determined by fetal MRI helps improve prognostic accuracy. (orig.)

  14. Functional-anatomic evaluation of dilated uropathies in children using combined MR-nephrography and MR-urography compared to renal scintigraphy; Funktionell-anatomische Diagnostik dilatierter Uropathien bei Kindern mit kombinierter MR-Nephrographie und MR-Urographie im Vergleich zur renalen Isotopennephrographie

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M. [Abt. fuer bildgebende Diagnostik am Kinderkrankenhaus Park Schoenfeld, Kassel (Germany); Tuerkay, S. [GE Medical Systems Deutschland GmbH, Solingen (Germany)

    2004-02-01

    Purpose: to evaluate MR-tomographic assessment of split renal function and degree of obstruction compared to diuretic renal scintigraphy, and pathoanatomic imaging of the urinary tract as all in one exam. Patients and methods: in a prospective study 62 children, aged 1 month to 9.5 years, mean 2.8 years, underwent diuretic renal scintigraphy and dynamic MR-nephrography at the same day except for 7 patients with a time interval of 1 day. In all patients we did T2w (water-technique) MR-urography additionally. Results: comparing spilt renal function we found a very close correlation in 54 out of 62 patients (correlation coefficient = 0.95). Due to technical failures 8 cases couldn't be calculated. Comparing degrees of obstruction there was an agreement in 57 out of 62 patients, 3 studies were gradually over-, 2 underestimated. All but one morphologic diagnoses in advance obtained by ultrasound and completed by other imaging modalities later on were confirmed MR-urographically. Though correctly imaged the functionless upper moiety in a renal duplication with ureterocele was misinterpreted at a first glance. (orig.) [German] Ziel: Es sollte geprueft werden, ob die Berechnung der seitengetrennten Nierenfunktion, die Bestimmung des Obstruktionsgrades und die pathoanatomische Darstellung des Harntraktes im Vergleich zur Diurese-Szintigraphie in einem Untersuchungsgang MR-tomographisch zuverlaessig moeglich ist. Patienten und Methode: In einer prospektiven Studie wurden bei 62 Kindern im Alter von 1 Monat bis 9,5 Jahren, Mittelwert 2,8 Jahre, ein Diurese-Szintigramm und eine dynamische MR-Nephrographie am gleichen Tag durchgefuehrt; lediglich bei 7 Patienten lag 1 Tag zwischen beiden Untersuchungen. Alle Patienten erhielten zusaetzlich eine T2w-MR-Urographie in ''Wasserbild''-Technik. Ergebnisse: Beim Vergleich der seitengetrennten Nierenfunktion fand sich eine sehr enge Korrelation bei 54 von insgesamt 62 Patienten (Korrelationskoeffizient = 0

  15. Correlation of angiography and MR imaging in cerebral vasculitis

    International Nuclear Information System (INIS)

    Cloft, H.J.; Phillips, C.D.; Dix, J.E.; McNulty, B.C.; Kallmes, D.F.; Zagardo, M.T.

    1999-01-01

    Purpose: MR imaging and cerebral angiography were correlated in patients with primary angiitis of the central nervous system (PACNS) to assess the relative roles of these imaging modalities in the diagnosis. Material and Methods: In 9 patients, MR imaging and angiography were compared with regard to the relative involvement of each major vascular territory. Vascular territories assessed were the anterior, middle, and posterior cerebral arteries, and the posterior fossa. Results: All patients had angiographic findings consistent with vasculitis in multiple vascular territories. MR findings ranged from normal to diffusely abnormal. One patient had a completely normal MR investigation. Of 50 territories affected by vasculitis on angiography, 17 (34%) were normal on MR. Conclusion: Relative to cerebral angiography, MR imaging is a poor indicator of the presence or absence of PACNS. Angiography is indicated when clinical suspicion of PACNS is strong, regardless of the findings on MR. (orig.)

  16. MR imaging of acute transverse myelitis (myelopathy)

    Energy Technology Data Exchange (ETDEWEB)

    Isoda, Haruo [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Ramsey, R.G.

    1998-05-01

    The purpose of our study was to review the MR characteristics of acute transverse myelitis (ATM) retrospectively and to review the literature. The subjects were 26 patients (two males, 24 females). MR examinations were carried out using a 1.5 Tesla scanner. MR imaging in eight of 16 lesions in nine subjects with preexisting MS showed multiple areas of increased signal intensity on T{sub 2}-weighted sagittal images, and 11 lesions had no cord swelling. Twelve of 16 lesions showed heterogeneous enhancement. MR imaging in 10 of 13 lesions in 12 subjects with preexisting HTLV-1 infection, mycoplasma pneumonia infection, hepatitis B vaccinations, and uncertain etiologies revealed fusiform increased signal intensity areas on T{sub 2}-weighted sagittal images and cord swelling. Seven of 11 lesions in the patients who underwent injection of contrast medium showed heterogeneous enhancement, whereas others showed no enhancement. MR examination is recommended for the evaluation of ATM. (author)

  17. MR plaque imaging of the carotid artery

    International Nuclear Information System (INIS)

    Watanabe, Yuji; Nagayama, Masako

    2010-01-01

    Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan. (orig.)

  18. MR appearance of skeletal neoplasms following cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, M.L. [Dept. of Radiology SB-05, Washington Univ., Seattle, WA (United States); Lough, L.R. [Pitts Radiological Associates, Columbia, SC (United States); Shuman, W.P. [Dept. of Radiology, Medical Center Hospital of Vermont, Burlington, VT (United States); Lazerte, G.D. [Dept. of Pathology RC-72, Washington Univ., Medical Center Hospital of Vermont, Burlington, VT (United States); Conrad, E.U. [Dept. of Orthopedic Surgery RK-10, Washington Univ., Medical Center of Vermont, Burlington, VT (United States)

    1994-02-01

    Cryotherapy is an increasingly popular mode of therapy adjunctive to surgical curettage in the treatment of certain skeletal neoplasms, such as giant cell tumors or chondrosarcomas. The magnetic resonance (MR) findings following cryotherapy have not been previously reported. We reviewed the MR findings in seven patients with skeletal neoplasms following curettage and cryotherapy. In six cases we found a zone of varying thickness extending beyond the surgical margins, corresponding to an area of cryoinjury to medullary bone. This zone displayed low signal intensity on T1-weighted images and high signal intensity on T2-weighted images, consistent with the presence of marrow edema. This zone of edema almost certainly reflects underlying thermal osteonecrosis. This zone may vary in size and intensity over time as the area of cryoinjury evolves or resolves. MR is currently the imaging procedure of choice for follow-up of most musculoskeletal neoplasms. Knowledge of the MR findings following cryotherapy should help prevent confusion during the interpretation of follow-up MR examinations. (orig.)

  19. MR appearance of skeletal neoplasms following cryotherapy

    International Nuclear Information System (INIS)

    Richardson, M.L.; Lough, L.R.; Shuman, W.P.; Lazerte, G.D.; Conrad, E.U.

    1994-01-01

    Cryotherapy is an increasingly popular mode of therapy adjunctive to surgical curettage in the treatment of certain skeletal neoplasms, such as giant cell tumors or chondrosarcomas. The magnetic resonance (MR) findings following cryotherapy have not been previously reported. We reviewed the MR findings in seven patients with skeletal neoplasms following curettage and cryotherapy. In six cases we found a zone of varying thickness extending beyond the surgical margins, corresponding to an area of cryoinjury to medullary bone. This zone displayed low signal intensity on T1-weighted images and high signal intensity on T2-weighted images, consistent with the presence of marrow edema. This zone of edema almost certainly reflects underlying thermal osteonecrosis. This zone may vary in size and intensity over time as the area of cryoinjury evolves or resolves. MR is currently the imaging procedure of choice for follow-up of most musculoskeletal neoplasms. Knowledge of the MR findings following cryotherapy should help prevent confusion during the interpretation of follow-up MR examinations. (orig.)

  20. Reflex sympathetic dystrophy syndrome: MR imaging study

    International Nuclear Information System (INIS)

    Masciocchi, C.; Fascetti, E.; Bonanni, G.; Calvisi, V.; Buoni, C.; Passariello, R.

    1987-01-01

    Reflex sympathetic dystrophy syndrome (RSDS) is characterized by pain, swelling, and limitation of motion. The etiology and pathophysiology mechanism have not yet been identified. We considered eight patients with clinical signs of RSDS, in five cases located at the knee joint and in three cases in the hip. In all cases conventional radiography and radionuclide bone scanning were performed before MR imaging. Conventional radiography was negative in three cases while scintigraphy demonstrated the lesion in all patients. MR imaging showed an area of low intensity signal on T1-weighted scans and an increased signal intensity on T2-weighted images. This area is located at the bone marrow and its regular and homogeneous. This specific finding on MR images is due to reflect edema by hyperemia of the bone marrow. The MR imaging diagnosis was confirmed on clinical and radiological follow-up. MR imaging can have a role in the differential diagnosis when other studies are nondiagnostic or nonspecific for RSDS

  1. Value of MR-angiography in brain infarction

    International Nuclear Information System (INIS)

    Pirronello, Veronica; Capizzano, Aristides A.; Chouela, Carolina L.; Ternak, Alejandro; Ramirez, Susana; Mazzuco, Juan C.

    2004-01-01

    A retrospective study has been performed in a series of 237 patients, with brain and neck MR and MR angiography techniques. 108/237 (45.5%) patients presented either hemorrhage or lacunar and non lacunar ischemic stroke, 67 of which showed restricted diffusion. Diffusion and perfusion techniques can significantly contribute to study acute stroke. In our series MR angiography showed a 4% sensitivity to detect small arteries pathology. (author)

  2. MR imaging exploration of the pituitary region

    International Nuclear Information System (INIS)

    Braun, M.; Roland, J.; Moret, C.; Picard, L.

    1992-01-01

    MR Imaging has become the procedure of choice for the exploration of the pituitary region. MR contrast resolution is far better than the finest CT examination, especially concerning the microadenomas and the neurohypophysis. The present paper concerns, at first the major principles of magnetic resonance imaging, its application for the study of the pituitary region including the use of contrast agent (Gadolinium). Lastly, MR anatomy and physiological variations are presented

  3. MR of experimental cerebral ischemia

    International Nuclear Information System (INIS)

    DeLaPaz, R.; Steinberg, G.; Rocklage, S.; Glover, G.H.

    1990-01-01

    This paper reports on MR imaging of cerebral ischemia and treatment with N-methyl-D-aspartate (NMDA) antagonists in an animal model. Forty-four New Zealand white rabbits underwent 1-hour transorbital ICA-MCA-ACA occlusion and pretreatment or immediate posttreatment with systemic dextromethorphan (DM, n = 14), dextrorphan (DX, n = 14), or normal saline (NS, n = 16). Serial MR studies (1.5 T) were performed 1--6 hours after occlusion with T1- and T2-weighted spinecho, IVIM (b = 1,352), gradient recalled acquisition in a steady-state, and chemical shift sequences (for magnetic susceptibility, T2* and T2') and DyDTPA-BMA intravenous contrast material (Salutar). Spatial correlation between MR findings, histologic findings (ischemic neuronal damage), and regional cerebral blood flow (microspheres) was done

  4. MR imaging findings and MR criteria for instability in osteochondritis dissecans of the elbow in children

    International Nuclear Information System (INIS)

    Jans, Lennart B.O.; Ditchfield, Michael; Anna, Gomez; Jaremko, Jacob L.; Verstraete, Koenraad L.

    2012-01-01

    Purpose: Osteochondritis dissecans (OCD) of the elbow is an uncommon cause of elbow pain in adolescents and occurs at different locations in the elbow joint. Early diagnosis and treatment may prevent surgery. The aim of the study is to describe the MR imaging features of OCD at initial imaging, and to correlate these findings with surgical findings of stability and instability with arthroscopic findings as the reference standard. Methods: Patients were identified through a keyword search of the radiology information system from 2000 to 2009. Twenty-five patients (26 elbows) with OCD of the elbow were identified (age 10.4–18 years, mean age 14 years). MR studies were retrospectively reviewed by two radiologists in consensus to define MR imaging findings and to determine the presence of previously described MR imaging criteria for OCD instability (i.e., high T2 signal rim, surrounding cysts, high T2 signal fracture line, fluid-filled osteochondral defect). Sensitivity of the individual and combined criteria was calculated. Results: OCD occurred in the capitellum in 24 patients (92%), in the trochlea in 2 patients (8%) and radial head in 1 patient (4%). Loose bodies were identified in 11 (42%) patients. Eighteen patients demonstrated MRI findings in keeping with unstable lesions. In all 11 patients who had surgery the surgical findings of instability correlated with the MRI findings. When combined, the MR criteria were 100% sensitive for instability of OCD lesions of the elbow. Conclusion: The vast majority of OCD of the elbow occurs in the capitellum. When used together, the MR criteria for instability were 100% sensitive for evaluation OCD lesions of the elbow.

  5. Knowledge-based interpretation of cranial MR images

    International Nuclear Information System (INIS)

    Kuhn, M.H.; Menhardt, W.; Schmidt, K.H.

    1987-01-01

    A computerized system is described that can be used to evaluate an MR tomogram automatically to support clinical identification of anatomic and pathologic structures and to aid in planning MR measurements. Knowledge from three domains is used for the interpretation of an MR image: nosologic knowledge, knowledge of MR imaging parameters, and anatomic and morphologic knowledge. Nosologic information is used to generate hypotheses about possible pathologies and their locations, based on the signs and symptoms of the patient. With this information, a sequence of interpretation modules, each able to detect substructures in already detected structures with the aid of techniques from image processing, pattern recognition, and artificial intelligence, is generated and executed

  6. How does Modernity Taste? Tomatoes in the Societal Change from Modernity to Late Modernity

    Directory of Open Access Journals (Sweden)

    Lena Ekelund

    2011-10-01

    Full Text Available The aim of this article is to discuss how changes in tomato food regulation, production and consumption, can be seen as part of a broader societal change from Modernity to Late Modernity. Based on evidence from the Swedish and European food systems we demonstrate how a system, which has been successfully managing development in food production for several decades by stressing rationality, homogeneity and standardization, is being challenged by a system that has adapted to, and also exploited, consumer preferences such as heterogeneity, diversity and authenticity. The article shows how tomato growers develop differentiation strategies, adapting to and cultivating this new consumer interest, and how authorities responsible for regulations of trade and quality struggle to adapt to the new situation. As the products become more diversified, taste becomes an important issue and is associated with a view that traditional and natural are superior to standardized and homogeneous products. The analytical approaches for the discussion come from two study areas: ethnological, and marketing and policy perspective, thus showing a multidimensional picture of a changing food system.

  7. Rapid myelin water content mapping on clinical MR systems

    Energy Technology Data Exchange (ETDEWEB)

    Tonkova, Vyara; Arhelger, Volker [Fachhochschule Koblenz, RheinAhrCampus Remagen (Germany); Schenk, Jochen [Radiologisches Institut, Koblenz (Germany); Neeb, Heiko [Fachhochschule Koblenz, RheinAhrCampus Remagen (Germany); Koblenz Univ. (Germany). Inst. for Medical Engineering and Information Processing - MTI Mittelrhein

    2012-07-01

    We present an algorithm for the fast mapping of myelin water content using standard multiecho gradient echo acquisitions of the human brain. The method extents a previously published approach for the simultaneous measurement of brain T{sub 1}, T{sup *}{sub 2} and total water content. Employing the multiexponential T{sup *}{sub 2} decay signal of myelinated tissue, myelin water content was measured based on the quantification of two water pools ('myelin water' and 'rest') with different relaxation times. As the existing protocol was focussed on the fast mapping of quantitative MR parameters with whole brain coverage in clinically relevant measurement times, the sampling density of the T{sup *}{sub 2} curve was compromised to 10 echo times with a T {sub Emax} of approx. 40 ms. Therefore, pool amplitudes were determined using a quadratic optimisation approach. The optimisation was constrained by including a priori knowledge about brain water pools. All constraints were optimised in a simulation study to minimise systematic error sources given the incomplete knowledge about the real pool-specific relaxation properties. Based on the simulation results, whole brain in vivo myelin water content maps were acquired in 10 healthy controls and one subject with multiple sclerosis. The in vivo results obtained were consistent with previous reports which demonstrates that a simultaneous whole brain mapping of T{sub 1}, T{sup *}{sub 2}, total and myelin water content is feasible on almost any modern MR scanner in less than 10 minutes. (orig.)

  8. Use of intravoxel incoherent motion diffusion-weighted MR imaging for assessment of treatment response to invasive fungal infection in the lung

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Chenggong; Xiong, Wei; Wu, Yuankui; Li, Caixia; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou (China); Xu, Jun; Wei, Qi; Feng, Ru; Liu, Qifa [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories, Hon Kong (China)

    2017-01-15

    The purpose of this study was to determine whether intravoxel incoherent motion (IVIM) -derived parameters and apparent diffusion coefficient (ADC) could act as imaging biomarkers for predicting antifungal treatment response. Forty-six consecutive patients (mean age, 33.9 ± 13.0 y) with newly diagnosed invasive fungal infection (IFI) in the lung according to EORTC/MSG criteria were prospectively enrolled. All patients underwent diffusion-weighted magnetic resonance (MR) imaging at 3.0 T using 11 b values (0-1000 sec/mm{sup 2}). ADC, pseudodiffusion coefficient D*, perfusion fraction f, and the diffusion coefficient D were compared between patients with favourable (n=32) and unfavourable response (n=14). f values were significantly lower in the unfavourable response group (12.6%±4.4%) than in the favourable response group (30.2%±8.6%) (Z=4.989, P<0.001). However, the ADC, D, and D* were not significantly different between the two groups (P>0.05). Receiver operating characteristic curve analyses showed f to be a significant predictor for differentiation, with a sensitivity of 93.8% and a specificity of 92.9%. IVIM-MRI is potentially useful in the prediction of antifungal treatment response to patients with IFI in the lung. Our results indicate that a low perfusion fraction f may be a noninvasive imaging biomarker for unfavourable response. (orig.)

  9. Overhauser-enhanced MR imaging (OMRI)

    International Nuclear Information System (INIS)

    Golman, K.; Leunbach, I.; Ardenkjaer-Larsen, J.H.; Wistrand, L.G.; Petersson, J.S.; Ehnholm, G.J.; Jaervi, A.; Vahasalo, S.

    1998-01-01

    Purpose: To evaluate a new single-electron contrast agent for Overhauser-enhanced MR imaging. The contrast agents that are currently available give enhancement factors that are too low to make the technique a valid option for routine clinical use. Material and Methods: MR images were generated directly following the injection of the substance into rats. The MR scanner was operated at a main magnetic field of 0.01 T and equipped with a separate rf-transmitter tuned to the electron paramagnetic resonance frequency of the contrast agent. Results: As expected, the images generated show a high level of enhancement in areas where the contrast agent was present, and a maximum enhancement of 60 times the normal proton signal was obtained in the vascular area. The signal-to-noise ratios in the images were superior to those previously attained. Conclusion: The new contrast agent makes it possible to generate MR images with both morphological and functional information at 0.01 T. The signal-to-noise ratios found in the generated images were of the same order as, or better than, those obtained with the standard clinical routine. (orig.)

  10. Evaluation of Nitrogen Uptake and Growth Performance of Advanced Mutant Lines MR219-4 and MR219-9 Grown Under Aerobic Conditions

    International Nuclear Information System (INIS)

    Shyful Azizi Abdul Rahman; Abdul Rahim Harun; Rusli Ibrahim; Khairuddin Abdul Rahim

    2014-01-01

    Developing a good crop production management package; drought resistance variety, effective water and nutrient management in rice production practices is crucial for global climate change adaptation. A research project under IAEA RAS5065 (Supporting Climate-Proofing Rice Production Systems (CRiPS) Based on Nuclear Applications) was conducted from 2012 to 2013, in collaboration with MARDI. Two advanced mutant lines, MR219-4 and MR219-9 were used in this research project to evaluate growth, yield potential and fertilizer uptake under different water input condition (flooded and aerobic). The advanced mutant line MR219-9 showed comparable growth, yield and nitrogen uptake under both flooded and aerobic conditions. The yield and yield components are not significantly different from the parent variety (MR219) but total N uptake was lower than MR219 regardless of water regime. The field trial showed that MR219-9 has a better total N content which is comparable to the aerobic rice variety (MRIA 1) and this indicates that this advance mutant line MR219-9 is a potential aerobic rice variety. (author)

  11. Changes of renal blood flow after ESWL: assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index.

    Science.gov (United States)

    Abd Ellah, Mohamed; Kremser, Christian; Pallwein, Leo; Aigner, Friedrich; Schocke, Michael; Peschel, Reinhard; Pedross, Florian; Pinggera, Germar-Michael; Wolf, Christian; Alsharkawy, Mostafa A M; Jaschke, Werner; Frauscher, Ferdinand

    2010-10-01

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12h before and 12h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (pESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  12. Correlation of CT and MR findings with clinical outcome

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Kim, In One; Choi, Du Hwan; Yeon, Kyung Mo; Hwang, Yong Seung

    1991-01-01

    A retrospective analysis of the CT and MR findings of 14 pediatric patients with brain stem tumors was performed to evaluate whether the clinical outcome could be predicted from a radiographic pattern of the tumors. CT was performed in 11 patients and MR was performed in 14 patients. Ten patients were treated with radiation therapy (RT) alone, 2 patients with RT and chemotherapy, and 2 patients underwent subtotal resection. After treatment, 9 patients died within 10 months, and 5 patients were alive for 9 months to 51 months. There was no statistically significant correlation between survival and tumor location or size, but in 2 cases of exophytic growing tumor, a subtotal resection of the tumor was possible and the patients were alive for 9 months and 24 months, respectively. The tumors with a cystic portion and definite rim enhancement revealed a poor response to conventional RT, and all 6 patients died within 10 months. In conclusion, a better prognosis is predicted in the case of an exophytic growing tumor after surgical resection, but the definite ring-enhancing tumor showed a poor response on conventional RT. Also, we should consider a more active therapeutic approach such as hyperfractionated RT or combinations of chemotherapy to improve the prognosis

  13. MR imaging of appendicular musculoskeletal trauma

    International Nuclear Information System (INIS)

    Kathol, M.H.; Montgomery, W.J.; Yuh, W.T.C.; El-Khoury, G.Y.

    1987-01-01

    Thirty cases of musculoskeletal trauma to the extremities examined by MR imaging have been reviewed retrospectively. Examples of various injuries will be shown, including disruption of ligament and tendon, muscular tear and edema, hemorrhage (local or diffuse), vascular injury, bone marrow contusion, osteocartilaginous fracture, meniscal tear, and joint fluid. Many of these patients were collegiate athletes, and MR was valuable in establishing a rapid, accurate diagnosis influencing not only treatment but also return to competition. Negative examinations allowed resumption of competition with a high degree of confidence. The advantages and disadvantages of MR in musculo-skeletal trauma are discussed

  14. Elucidating the Molecular Basis and Regulation of Chromium (VI) Reduction by Shewanella oneidensis MR-1 Using Biochemical, Genomic, and Proteomic Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hettich, Robert L.

    2006-10-30

    Although microbial metal reduction has been investigated intensively from physiological and biochemical perspectives, little is known about the genetic basis and regulatory mechanisms underlying the ability of certain bacteria to transform, detoxify, or immobilize a wide array of heavy metals contaminating DOE-relevant environments. The major goal of this work is to elucidate the molecular components comprising the chromium(VI) response pathway, with an emphasis on components involved in Cr(VI) detoxification and the enzyme complex catalyzing the terminal step in Cr(VI) reduction by Shewanella oneidensis MR-1. We have identified and characterized (in the case of DNA-binding response regulator [SO2426] and a putative azoreductase [SO3585]) the genes and gene products involved in the molecular response of MR-1 to chromium(VI) stress using whole-genome sequence information for MR-1 and recently developed proteomic technology, in particular liquid chromatographymass spectrometry (LC-MS), in conjunction with conventional protein purification and characterization techniques. The proteome datasets were integrated with information from whole-genome expression arrays for S. oneidensis MR-1 (as illustrated in Figure 1). The genes and their encoded products identified in this study are of value in understanding metal reduction and bacterial resistance to metal toxicity and in developing effective metal immobilization strategies.

  15. MR findings in iliotibial band syndrome

    International Nuclear Information System (INIS)

    Nishimura, G.; Yamato, M.; Tamai, K.; Takahashi, J.; Uetani, M.

    1997-01-01

    Objective. To elucidate the MR findings in iliotibial band (ITB) syndrome. Design and patients. The subjects comprised four patients (five knees) with lateral knee pain: two athletes and two non-athletes. One non-athlete was engaged in work requiring repetitive knee movement, and the other suffered from Cushing syndrome and had bilateral abnormalities. All patients were suspected of having a lateral meniscal tear prior to MR examination, but physical examination following provisional MR diagnosis warranted the final diagnosis. MR studies included fast spin echo sagittal imaging, fat-saturated fast spin echo proton density coronal imaging, and T2* radial imaging. Twelve normal volunteers were examined. Results and conclusion. Fat-saturated coronal imaging demonstrated an ill-defined, high-intensity area deep to the ITB. T2* radial imaging showed an identical, but less conspicuous, abnormality. The MR finding suggested soft tissue inflammation and/or edema rather than focal fluid collection in the bursae. The signal alteration predominated in the region beneath the posterior fibers of the ITB, thus supporting the current opinion that the posterior fibers of the ITB are tighter against the lateral femoral epicondyle than the anterior fibers. The ITB itself did not show any signal alteration or increased thickness. (orig.). With 4 figs., 1 tab

  16. MR imaging of transient synovitis: differentiation from septic arthritis

    International Nuclear Information System (INIS)

    Yang, W.J.; Im, S.A.; Lim, G.Y.; Chun, H.J.; Jung, N.Y.; Sung, M.S.; Choi, B.G.

    2006-01-01

    Transient synovitis is the most common cause of acute hip pain in children. However, MR imaging findings in transient synovitis and the role of MR imaging in differentiating transient synovitis from septic arthritis have not been fully reported. To describe the MR findings of transient synovitis and to determine whether the MR characteristics can differentiate this disease entity from septic arthritis. Clinical findings and MR images of 49 patients with transient synovitis (male/female 36/13, mean age 6.1 years) and 18 patients with septic arthritis (male/female 10/8, mean age 4.9 years) were retrospectively reviewed. MR findings of transient synovitis were symptomatic joint effusion, synovial enhancement, contralateral joint effusion, synovial thickening, and signal intensity (SI) alterations and enhancement in surrounding soft tissue. Among these, SI alterations and enhancement in bone marrow and soft tissue, contralateral joint effusion, and synovial thickening were statistically significant MR findings in differentiating transient synovitis from septic arthritis. The statistically significant MR findings in transient synovitis are contralateral (asymptomatic) joint effusions and the absence of SI abnormalities of the bone marrow. It is less common to have SI alterations and contrast enhancement of the soft tissues. The statistically significant MR findings in septic arthritis are SI alterations of the bone marrow, and SI alterations and contrast enhancement of the soft tissue. Ipsilateral effusion and synovial thickening and enhancement are present in both diseases

  17. MR imaging of the pulmonary vasculature - an update

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Mark R.; Fisher, Mark T. [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); Beek, Edwin J.R. van [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); University of Iowa Hospitals and Clinics, JPP 3895, Department of Radiology, Iowa City, Iowa (United States)

    2006-06-15

    Although the advent of multi-detector row computed tomography (CT) angiography has been at the heart of improving the diagnostic management of pulmonary vascular disease, MR technology has also moved forward. This review outlines the current state of affairs of MR techniques for the assessment of pulmonary vascular diseases such as pulmonary hypertension, pulmonary arteritis and arteriovenous malformations. It highlights the main areas of MR angiography and MR perfusion imaging and discusses novel methods, such as non-contrast enhanced direct thrombus imaging, and will discuss its merits in the context of other diagnostic modalities. (orig.)

  18. Fast FLAIR MR images of intracranial hemorrhage

    International Nuclear Information System (INIS)

    Chun, Eun Ju; Choi, Hye Young; Cho, Young A; Kim, Wha Young

    1998-01-01

    The purpose of this study is to evaluate the signal characteristics of intracranial hemorrhage, as seen on fluid attenuated inversion recovery (FLAIR) MR imaging according to various stages, and to compare FLAIR imaging with spin-echo T1- and T2-weighted MR imaging. We retrospectively evaluated fast FLAIR images along with spin-echo T1- and T2 weighted MR images of 32 lesions in 25 patients (12 males and 14 females, aged 3 - 84 yrs) with intracranial hemorrhagic lesions. For imaging, 1.5 T unit was used, and the nature of the lesions was found to be as follows : intracranial hemorrhage (n=15); tumor (n=9); infarction (n=4); arteriovenous malformation (n=3); and arachnoid cyst with hemorrhage (n=1). On the basis of spin-echo MR imaging, lesions were classified as acute, early subacute, late subacute, early chronic, or late chronic stage. The signal characteristics of intracranial hemorrhage were analysed in accordance with each staging, as seen on MR FLAIR imaging, and compared to the staging seen on spin-echo T1- and T-2 weighted MR imaging. The signal intensity of intracranial hemorrhage, as seen on FLAIR imaging, was not characteristic; it was similar to that of T2WI during the acute and subacute stages, and similiar to that of T1WI during the chronic stage. When used together with spin-echo T1- and T2-weighted MR imaging, however, FLAIR imaging may be useful for the classification of chronic intracranial hemorrhage as either early or late stage. (author). 20 refs., 2 tabs., 6 figs

  19. MR imaging of brachial plexus

    International Nuclear Information System (INIS)

    Carriero, A.; Ciccotosto, C.; Dragani, M.; Manes, L.; Bonomo, L.

    1991-01-01

    The brachial plexus is a difficult region to evaluate with radiological techniques. MR imaging has great potentials for the depiction of the various anatomical structures of the branchial plexus - i.e., spinal ganglion, ventral nerve rami root exit of the neural foramina, trunks an cordes. Moreover, MR imaging, thanks to its direct multiplanarity, to its excellent soft-tissue contrast, and to its lack of motion artifacts, allows good evaluation of pathologic conditions in the branchial plexus, especially traumas and cancers. On the contrary CT, in spite of its high spatial resolution and good contrast, cannot demonstrate the anatomical structures of the brachial plexus. US detects superficials structures, and conventional radiographs depict only indirect changes in the adjacent lung apex and skeletal structures. From November 1989 to May 1990, 20 normal volunteers (15 males and 5 females; average age: 35 years) were studied with MR imaging. Multisection technique was employed with a dedicated coil and a primary coil. The anatomical structures of the brachial plexus were clearly demonstrated by T1-weighted sequences on the sagittal and axial planes. T2-weighted pulse sequences on the coronal plane were useful for the anatomical definition of the brachial plexus and for eventual tissue characterization. The correct representation of the anatomical structures of the brachial plexus allowed by MR imaging with author's standard technique makes MR imaging the most appropriate exam for the diagnosis of pathologic conditions in the brachial plexus, although its use must be suggested by specific clinical questions

  20. Usefulness of perfusion MR imaging in hyperacute ischemic stroke

    International Nuclear Information System (INIS)

    Park, Ji Hoon; Kim, Jae Hyoung; Shin, Tae Min; Lee, Eun Ja; Chung, Sung Hoon; Choi, Nack Cheon; Lim, Byeong Hoon; Kim, In One

    1998-01-01

    Perfusion MR imaging is a new technique for the assessment of acute ischemic stroke. The aim of this study was to evaluate the usefulness of this imaging in hyperacute ischemic stroke in comparison with conventional CT and MR imaging. Eight patients presenting the symptoms of acute ischemic stroke due to middle cerebral artery occlusion were included in this study. Within 2 hours of initial CT scan and 6 hours after the onset of stroke, perfusion MR imaging was performed in all patients using a single-section dynamic contrast-enhanced T2*-weighted imager in conjunction with conventional routine MR imaging and MR angiography. Cerebral blood volume (CBV) maps were then obtained from dynamic MR imaging data by using numerical integration techniques. The findings of CBV maps were compared with those of initial and follow-up CT or MR images. The findings of CBV maps were obviously abnormal in all patients, as compared with normal or focal subtle abnormal findings seen on initial CT and MR images. CBV in the occluded arterial territory was lower in all eight patients;two had focal regions of increased CBV within the affected territory, indicating reperfusion hyperemia. In all patients, regions of abnormal CBV were eventually converted to infarctions on follow-up images. Perfusion MR imaging was useful for the evaluation of hemodynamic change occurring during cerebral perfusion in hyperacute ischemic stroke, and prediction of the final extent of infarction. These results suggest that pertusion MR imaging can play an important role in the diagnosis and management of hyperacute ischemic stroke.=20

  1. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  2. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  3. The MR evaluation of pachygyria and associated syndromes

    International Nuclear Information System (INIS)

    Byrd, S.E.; Radkowski, M.A.; Northwestern Univ., Chicago, IL; Osborn, R.E.

    1991-01-01

    A retrospective study of 40 children with some form of pachygyria was performed at the Children's Memorial Hospital in Chicago. All children had MR brain scans. The MR findings were analyzed, and correlated with the clinical symptoms and course in all the children. 15 percent had autopsy findings. Based on the clinical, MR and autopsy findings, in conjunction with the medical literature, the following was found: (1) Pachygyria can occur as an isolated entity without an association with lissencephaly. The MR findings in these children consisted of a brain that demonstrated normal opercularization with either focal or diffuse areas of pachygyria without areas of agyria. These children live longer and have less severity of symptoms than the children with lissencephaly. (2) The MR findings in children with lissencephaly consisted of a brain that demonstrated abnormal oper-cularization with areas of total agyria or areas with agyria with pachygyria. (3) The MR findings in 25 percent of the children with poly-microgyria simulated pachygyria. The MR findings of the brain in these children consisted of a 'nubby' appearance to the outer surface of these abnormal gyri which resembled pachygyria but on histologic exam was polymicrogyria. (author). 11 refs.; 7 figs.; 1 tab

  4. Reconversion of bone marrow in Gaucher disease treated with enzyme therapy documented by MR

    International Nuclear Information System (INIS)

    Allison, J.W.; James, C.A.; Arnold, G.L.; Stine, K.C.; Becton, D.L.; Bell, J.M.

    1998-01-01

    Background. Skeletal complications are responsible for significant morbidity in Gaucher patients. Plain radiographs have been unreliable in assessing bone marrow infiltration and activity. A way to assess bone marrow improvement is needed during enzyme therapy. Objective. The purpose of this paper is to assess the usefulness of MR in following improvement of abnormal bone marrow in Gaucher patients on enzyme therapy. Materials and methods. Three patients aged 2, 7, and 24 years underwent serial MR scans of the lower extremities before and during treatment with Alglucerase (two patients) and Imiglucerase (one patient). T1-weighted, T2-weighted, STIR and FSE T2-weighted images were utilized. Two patients were imaged after 16 months of therapy, and one patient was imaged after 6 months of therapy. Results. All patients had improvement in marrow signal consistent with partial reconversion to fatty marrow during treatment. The findings were more marked after prolonged therapy. T1-weighted images demonstrated findings most clearly. Conclusion. MR consistently showed improvement in marrow signal in Gaucher patients on enzyme therapy. As smaller doses of enzyme therapy are the trend, MR can be utilized to determine if therapy is effecting a change in the bone marrow. (orig.)

  5. Combined PET/MR imaging in neurology

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Ladefoged, Claes Nøhr; Beyer, Thomas

    2014-01-01

    AIM: Combined PET/MR systems have now become available for clinical use. Given the lack of integrated standard transmission (TX) sources in these systems, attenuation and scatter correction (AC) must be performed using the available MR-images. Since bone tissue cannot easily be accounted for duri...

  6. Clinical PET/MR Imaging in Oncology

    DEFF Research Database (Denmark)

    Kjær, Andreas; Torigian, Drew A.

    2016-01-01

    . The question, therefore, arises regarding what the future clinical applications of PET/MR imaging will be. In this article, the authors discuss ways in which PET/MR imaging may be used in future applications that justify the added cost, predominantly focusing on oncologic applications. The authors suggest...

  7. PET/MR imaging of the pelvis in the presence of endoprostheses

    DEFF Research Database (Denmark)

    Ladefoged, Claes Nøhr; Andersen, Flemming Littrup; Keller, Sune Høgild

    2013-01-01

    In combined whole-body PET/MR, attenuation correction (AC) is performed indirectly using the available MR image information and subsequent segmentation. Implant-induced susceptibility artifacts and subsequent signal voids may challenge MR-based AC (MR-AC). We evaluated the accuracy of MR-AC in PE...

  8. Assessing Biological Response to Bevacizumab Using 18F-Fluoromisonidazole PET/MR Imaging in a Patient with Recurrent Anaplastic Astrocytoma

    Directory of Open Access Journals (Sweden)

    Ramon F. Barajas

    2015-01-01

    Full Text Available We present our initial experience in using single modality fluoromisonidazole (FMISO PET/MR imaging to noninvasively evaluate the biological effects induced by bevacizumab therapy in a patient treated for recurrent high grade glioma. In this index patient, bevacizumab therapy resulted in the development of nonenhancing tumor characterized by reduced diffusion and markedly decreased FMISO uptake in the setting of maintained CBF and CBV. These observations suggest that the dynamic biological interplay between tissue hypoxia and vascular normalization occurring within treated recurrent high grade glioma can be captured utilizing FMISO PET/MR imaging.

  9. Cellular MR Imaging

    Directory of Open Access Journals (Sweden)

    Michel Modo

    2005-07-01

    Full Text Available Cellular MR imaging is a young field that aims to visualize targeted cells in living organisms. In order to provide a different signal intensity of the targeted cell, they are either labeled with MR contrast agents in vivo or prelabeled in vitro. Either (ultrasmall superparamagnetic iron oxide [(USPIO] particles or (polymeric paramagnetic chelates can be used for this purpose. For in vivo cellular labeling, Gd3+- and Mn2+- chelates have mainly been used for targeted hepatobiliary imaging, and (USPIO-based cellular imaging has been focused on imaging of macrophage activity. Several of these magneto-pharmaceuticals have been FDA-approved or are in late-phase clinical trials. As for prelabeling of cells in vitro, a challenge has been to induce a sufficient uptake of contrast agents into nonphagocytic cells, without affecting normal cellular function. It appears that this issue has now largely been resolved, leading to an active research on monitoring the cellular biodistribution in vivo following transplantation or transfusion of these cells, including cell migration and trafficking. New applications of cellular MR imaging will be directed, for instance, towards our understanding of hematopoietic (immune cell trafficking and of novel guided (stem cell-based therapies aimed to be translated to the clinic in the future.

  10. Evaluation of fetal anomalies with MR imaging

    International Nuclear Information System (INIS)

    Benson, R.C.; Platt, L.D.; Colletti, P.M.; Raval, J.K.; Boswell, W.D. Jr.; Halls, J.M.

    1987-01-01

    Twenty pregnant women underwent MR imaging (0.5 T) after US disclosed a significant fetal anomaly. The ability of MR imaging to depict the abnormalities was assessed. Of 20 abnormalities, 17 were visualized with MR imaging. Abnormalities included conjoined twins, omphalocele, gastroschisis, hydrocephalus, hydronephrosis, fetal ascites, facial teratoma, anencephaly, bladder outlet obstruction, thanatophoric dwarfism, cystic, hygroma, and fetal ovarian cyst. Thirteen of 14 abnormalities in third-trimester fetuses were visualized, as were four of six abnormalities in second-trimester fetuses. Associated polyhydramnios or oligohydramnios was evident in six of six cases. Anomalies were best delineated with T1-weighted sequences. The study suggests that MR imaging is potentially useful as a complementary imaging modality in the evaluation of fetal anomalies

  11. A typical MR imaging of multiple sclerosis

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Kan, Shinichi; Ikeda, Toshiaki; Nishiyama, Syougo; Nishimaki, Hiroshi; Matsubayashi, Takashi; Hata, Takashi

    1995-01-01

    MR imaging is very useful in detecting the intracranial lesion of multiple sclerosis (MS). We present six patients of MS with atypical MR imaging findings. Six patients aged 27-56 years (mean 36 years), and sexuality of six patients were 2 men and 4 females. Three patient's clinical course had episodes of optic neuritis. The plaque's size of the predominant lesion of the patients ranged from 3.0 to 9.0 cm in diameter. The plaques were oval, elliptically and other shaped. At acute stage, MR imaging detected perfocal edema and focal mass effect in three cases of our study. Two out of six cases showed multiple irregularly enhancing lesion with Gadolinium-DTPA. Plaques of all cases did not disappear completely in final MR imaging study. (author)

  12. MR findings of cerebral palsy and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ho; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To demonstrate MR findings of cerebral palsy (CP), correlation with clinical findings, and differences between the full-term and pre-term group. Brain MRI of 94 patients with cerebral palsy (CP) were reviewed. The frequency of each MR finding, statistical correlation with clinical findings including type, severity and extent of CP, and differences between the full-term and pre-term group were analyzed. Abnormal MR findings were found in 83 patients(88%), and were as follows : diffuse brain atrophy(30%); periventricular leukomalacia(PVL)(28%); infarction(11%), basal ganglia abnormality(11%); delayed myelination(10%); nonspecific tissue loss or encephalomalacia(9%); and cortical dysplasia(7%). Hemiplegia was the most common condition among patients with infarction, and was found in 80% of this group; diplegia was found in 50% of cases with diffuse brain atrophy, while paraplegia was found in 36% of those with normal MR findings (p < .05). Mild symptoms were dominant in patients with normal MR findings(82%) and in those with infarctions(90%)(p < .05). PVL was the dominant finding in the pre-term group (65%) whereas findings in the full-term group varied; in this group, 38% of MR findings suggested prenatal insults. Possible causative factors were found in 66% of the full-term and 80% of the pre-term group. Perinatal factors were dominant in the pre-term group(81%), whereas prenatal and postnatal factors showed relatively higher frequencies in the full-term group(30% and 24%, respectively). Diffuse brain atrophy and PVL were the most common MR findings. The extent of CP the pre-term correlated well with MR findings. PVL and perinatal factors were dominant in the pre-term group, whereas variable MR findings and relatively higher frequencies of pre- and postnatal factors were found in the full-term group.

  13. MR findings of cerebral palsy and clinical correlation

    International Nuclear Information System (INIS)

    Kim, Sun Ho; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo

    1997-01-01

    To demonstrate MR findings of cerebral palsy (CP), correlation with clinical findings, and differences between the full-term and pre-term group. Brain MRI of 94 patients with cerebral palsy (CP) were reviewed. The frequency of each MR finding, statistical correlation with clinical findings including type, severity and extent of CP, and differences between the full-term and pre-term group were analyzed. Abnormal MR findings were found in 83 patients(88%), and were as follows : diffuse brain atrophy(30%); periventricular leukomalacia(PVL)(28%); infarction(11%), basal ganglia abnormality(11%); delayed myelination(10%); nonspecific tissue loss or encephalomalacia(9%); and cortical dysplasia(7%). Hemiplegia was the most common condition among patients with infarction, and was found in 80% of this group; diplegia was found in 50% of cases with diffuse brain atrophy, while paraplegia was found in 36% of those with normal MR findings (p < .05). Mild symptoms were dominant in patients with normal MR findings(82%) and in those with infarctions(90%)(p < .05). PVL was the dominant finding in the pre-term group (65%) whereas findings in the full-term group varied; in this group, 38% of MR findings suggested prenatal insults. Possible causative factors were found in 66% of the full-term and 80% of the pre-term group. Perinatal factors were dominant in the pre-term group(81%), whereas prenatal and postnatal factors showed relatively higher frequencies in the full-term group(30% and 24%, respectively). Diffuse brain atrophy and PVL were the most common MR findings. The extent of CP the pre-term correlated well with MR findings. PVL and perinatal factors were dominant in the pre-term group, whereas variable MR findings and relatively higher frequencies of pre- and postnatal factors were found in the full-term group

  14. Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system

    International Nuclear Information System (INIS)

    Weihrauch, Mirko; Wust, Peter; Weiser, Martin; Nadobny, Jacek; Eisenhardt, Steffen; Budach, Volker; Gellermann, Johanna

    2007-01-01

    A combined numerical-experimental iterative procedure, based on the Gauss-Newton algorithm, has been developed for control of magnetic resonance (MR)-guided hyperthermia (HT) applications in a hybrid MR-HT system BSD 2000 3D-MRI. In this MR-HT system, composed of a 3-D HT applicator Sigma-Eye placed inside a tunnel-type MR tomograph Siemens MAGNETOM Symphony (1.5 T), the temperature rise due to the HT radiation can be measured on-line in three dimensions by use of the proton resonance frequency shift (PRFS) method. The basic idea of our iterative procedure is the improvement of the system's characterization by a step-by-step modification of the theoretical HT antenna profiles (electric fields radiated by single antennas). The adaptation of antenna profiles is efficient if the initial estimates are radiation fields calculated from a good a priori electromagnetic model. Throughout the iterative procedure, the calculated antenna fields (FDTD) are step-by-step modified by comparing the calculated and experimental data, the latter obtained using the PRFS method. The procedure has been experimentally tested on homogeneous and inhomogeneous phantoms. It is shown that only few comparison steps are necessary for obtaining a dramatic improvement of the general predictability and quality of the specific absorption rate (SAR) inside the MR-HT hybrid system

  15. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  16. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J.; Engel, A. Jr.; Stiglbauer, R. Jr.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper demonstrates the diagnostic value of MR arthrography in the assessment of cartilaginous lesions, including osteochondritis dissecans. One hundred thirty-two knees of 125 patients were examined with MR arthrography performed on a 1.5-T magnet with a knee resonator. T1-weighted spin-echo and T2*-weighted three-dimensional gradient-echo sequences were obtained after intraarticular administration of 40 mL of 2-mmol GD-DTPA solution. Seventy-five patients were also imaged without contrast agent. The description of the articular surface was classified into four types: I, normal cartilage surface and thickness; II, surface normal or slightly irregular; III, severe surface irregularities and cartilage defects; and IV, extensive cartilage defects, scar formation. MR findings were correlated with those of arthroscopy/arthrotomy (n = 75)

  17. MR findings of spondylolysis

    International Nuclear Information System (INIS)

    Ojiri, Hiroya; Fukuda, Kunihiko; Hashimoto, Toru; Doi, Michiko; Irie, Takeo; Tatsuno, Satoshi; Tada, Shinpei; Toyoda, Keiko.

    1994-01-01

    We reviewed MR images of 50 patients with spondylolisthesis to disclose MR findings of spondylolysis. In almost half of our series, spondylolysis was detected as a low signal intensity band traversing in the pairs interarticularis on both T1 and T2 weighted images. Sagittal images was superior to axial image in detection of the low signal intensity band. In some patients, a focal high signal intensity accompanying the low signal intensity band was considered to be fluid collection within pseudoarthrosis due to spondylolysis on T2-weighted image. (author)

  18. MR findings of spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Ojiri, Hiroya; Fukuda, Kunihiko; Hashimoto, Toru; Doi, Michiko; Irie, Takeo; Tatsuno, Satoshi; Tada, Shinpei (Jikei Univ., Tokyo (Japan). School of Medicine); Toyoda, Keiko

    1994-08-01

    We reviewed MR images of 50 patients with spondylolisthesis to disclose MR findings of spondylolysis. In almost half of our series, spondylolysis was detected as a low signal intensity band traversing in the pairs interarticularis on both T1 and T2 weighted images. Sagittal images was superior to axial image in detection of the low signal intensity band. In some patients, a focal high signal intensity accompanying the low signal intensity band was considered to be fluid collection within pseudoarthrosis due to spondylolysis on T2-weighted image. (author).

  19. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Liu, M; Hearshen, D; Brown, S; Siddiqui, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable

  20. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G; Kadbi, M; Blencowe, A

    2016-01-01

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe 3+ ) reduction versus ferrous ion (Fe 2+ ) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T 1 -weighted and inversion recovery sequences). Results: Irradiation of Fe 3+ reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R 2 =1.00). T 1 -weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe 2+ oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T 1 -weighted-MR SI, and R 1 relative to dose exhibited a linear response up to at least 8 Gy (R 2 =1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T 1 -weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R 2 >0.93). Conclusion: The Fe 2+ oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe 3+ reduction system is recommended for high

  1. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States); Kadbi, M [MR Therapy, Philips healthTech, Cleveland, OH (United States); Blencowe, A [The University of South Australia, South Australia, SA (Australia)

    2016-06-15

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose

  2. A wavelet multiscale denoising algorithm for magnetic resonance (MR) images

    International Nuclear Information System (INIS)

    Yang, Xiaofeng; Fei, Baowei

    2011-01-01

    Based on the Radon transform, a wavelet multiscale denoising method is proposed for MR images. The approach explicitly accounts for the Rician nature of MR data. Based on noise statistics we apply the Radon transform to the original MR images and use the Gaussian noise model to process the MR sinogram image. A translation invariant wavelet transform is employed to decompose the MR 'sinogram' into multiscales in order to effectively denoise the images. Based on the nature of Rician noise we estimate noise variance in different scales. For the final denoised sinogram we apply the inverse Radon transform in order to reconstruct the original MR images. Phantom, simulation brain MR images, and human brain MR images were used to validate our method. The experiment results show the superiority of the proposed scheme over the traditional methods. Our method can reduce Rician noise while preserving the key image details and features. The wavelet denoising method can have wide applications in MRI as well as other imaging modalities

  3. MR imaging of the brain in neurofibromatosis

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Cohen, M.L.; Duffner, P.K.; Seidel, F.; Harwood-Nash, D.

    1986-01-01

    Fifteen children and young adults with neurofibromatosis underwent CT and MR imaging (0.5-T superconducting magnet). Seven had optic gliomas and five had other intracranial neoplasms. Before thin-section MR imaging became available, CT was superior for demonstrating the optic nerves, although MR imaging better delineated tumor spread to the optic chiasm and tract. MR imaging was superior for demonstrating other gliomatous lesions associated with neurofibromatosis. Most lesions had long T1 and T2 values and were best seen on T2-weighted images. MR imaging revealed small areas of increased signal intensity on T2-weighted images in nearly half the patients. These lesions were not apparent on CT and were usually located in the globus pallidus, but were seen in many areas of the brain, commonly in the white matter, and in the brain steam and the cerebellar peduncles. Their exact etiology is unknown. Their imaging characteristics are somewhat different from those of gray matter. They may represent hamartomas or areas of glial scarring. Differentiation from a small glioma is presently not possible on a single examination

  4. Seismic performance evaluation of an MR elastomer-based smart base isolation system using real-time hybrid simulation

    International Nuclear Information System (INIS)

    Eem, S H; Jung, H J; Koo, J H

    2013-01-01

    Recently, magneto-rheological (MR) elastomer-based base isolation systems have been actively studied as alternative smart base isolation systems because MR elastomers are capable of adjusting their modulus or stiffness depending on the magnitude of the applied magnetic field. By taking advantage of the MR elastomers’ stiffness-tuning ability, MR elastomer-based smart base isolation systems strive to alleviate limitations of existing smart base isolation systems as well as passive-type base isolators. Until now, research on MR elastomer-based base isolation systems primarily focused on characterization, design, and numerical evaluations of MR elastomer-based isolators, as well as experimental tests with simple structure models. However, their applicability to large civil structures has not been properly studied yet because it is quite challenging to numerically emulate the complex behavior of MR elastomer-based isolators and to conduct experiments with large-size structures. To address these difficulties, this study employs the real-time hybrid simulation technique, which combines physical testing and computational modeling. The primary goal of the current hybrid simulation study is to evaluate seismic performances of an MR elastomer-based smart base isolation system, particularly its adaptability to distinctly different seismic excitations. In the hybrid simulation, a single-story building structure (non-physical, computational model) is coupled with a physical testing setup for a smart base isolation system with associated components (such as laminated MR elastomers and electromagnets) installed on a shaking table. A series of hybrid simulations is carried out under two seismic excitations having different dominant frequencies. The results show that the proposed smart base isolation system outperforms the passive base isolation system in reducing the responses of the structure for the excitations considered in this study. (paper)

  5. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    Energy Technology Data Exchange (ETDEWEB)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min [Chonbuk Narional University Hospital, Chonju (Korea, Republic of); Ym, Seong Hee [Namwon Medical Center, Chonju (Korea, Republic of)

    2000-09-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  6. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min; Ym, Seong Hee

    2000-01-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  7. Fundamentals of quantitative dynamic contrast-enhanced MR imaging.

    Science.gov (United States)

    Paldino, Michael J; Barboriak, Daniel P

    2009-05-01

    Quantitative analysis of dynamic contrast-enhanced MR imaging (DCE-MR imaging) has the power to provide information regarding physiologic characteristics of the microvasculature and is, therefore, of great potential value to the practice of oncology. In particular, these techniques could have a significant impact on the development of novel anticancer therapies as a promising biomarker of drug activity. Standardization of DCE-MR imaging acquisition and analysis to provide more reproducible measures of tumor vessel physiology is of crucial importance to realize this potential. The purpose of this article is to review the pathophysiologic basis and technical aspects of DCE-MR imaging techniques.

  8. Characteristic MR spectroscopy in fucosidosis: in vitro investigation

    Energy Technology Data Exchange (ETDEWEB)

    Mamourian, Alex C.; Chawla, Sanjeev; Poptani, Harish [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Hopkin, Jeremy R. [Barrow Neurological Institute, Department of Neuroradiology, Phoenix, AZ (United States)

    2010-08-15

    Fucosidosis is a rare lysosomal storage disorder that results in the deposition of the sugar fucose within various organs, including the central nervous system. Neuroimaging abnormalities on MR, specifically T2 shortening in the basal ganglia, have been reported as suggestive of fucosidosis. A more recent report of MR spectroscopy (MRS) of one patient provided evidence that MRS is specific for fucosidosis. We present another confirmed case with nearly identical MR spectroscopic findings along with in vitro data that support the contention that MR spectroscopy, in the setting of typical clinical and imaging features, is characteristic for this rare disorder. (orig.)

  9. Characteristic MR spectroscopy in fucosidosis: in vitro investigation

    International Nuclear Information System (INIS)

    Mamourian, Alex C.; Chawla, Sanjeev; Poptani, Harish; Hopkin, Jeremy R.

    2010-01-01

    Fucosidosis is a rare lysosomal storage disorder that results in the deposition of the sugar fucose within various organs, including the central nervous system. Neuroimaging abnormalities on MR, specifically T2 shortening in the basal ganglia, have been reported as suggestive of fucosidosis. A more recent report of MR spectroscopy (MRS) of one patient provided evidence that MRS is specific for fucosidosis. We present another confirmed case with nearly identical MR spectroscopic findings along with in vitro data that support the contention that MR spectroscopy, in the setting of typical clinical and imaging features, is characteristic for this rare disorder. (orig.)

  10. Implantate und Verfahren in der Augenheilkunde

    Science.gov (United States)

    Neuhann, Tobias H.

    Das in der Medizin mit am häufigsten verwendete Implantat weltweit ist die Intraokulare Linse (IOL). Die Gründe hierfür sind vielschichtig: einmal haben die Operationstechniken in den letzten 30 Jahren eine wesentliche Steigerung an Gleichmäßigkeit, Erfolg und Effizienz erfahren, zum anderen verursachen die gestiegenen Anforderungen des Alltags in den Industrienationen und im Berufsleben den höheren Anspruch an das Sehvermögen. Ist die menschliche Linse Ursache für schlechtes Sehvermögen, besteht meist eine Trübung des Linsenproteins. Diese Trübung nennt wird Volksmund Grauer Star genannt, wissenschaftlich die Katarakt (cataracta). Es gibt unterschiedliche Formen wie angeborene (congenita) oder erworbene, traumatische, krankheitsoder altersbedingte Formen [45]. Wird die eingetrübte Linse nun mittels moderner Operationsverfahren entfernt, muss für Ersatz dieses lichtbrechenden Mediums gesorgt werden [2].

  11. MR imaging of neonatal cerebral infarction

    International Nuclear Information System (INIS)

    McArdle, C.B.; Mehta, S.D.; Kulkarni, M.V.; Keeney, S.A.; Hayden, C.K.; Adcock, E.W. III.

    1987-01-01

    Twenty-six neonatal infarcts were imaged with 0.6 T and 1.5-T magnets and correlated with US and/or CT. Periventricular leukomalacia (PVL) was seen in six cases: lobar infarction, ten cases; global infarction, six cases; and basal ganglia infarction, four cases. MR imaging was superior to US and CT in detecting hemorrhagic PVL and basal ganglia infarcts. MR demonstrates lobar infarcts better than US and CT because of a wider field of view, specificty, and improved gray and white matter differentiation. US underestimates the extent of brain destruction in global infarcts. These results indicate that MR is the single best imaging modality for detecting ischemic brain injury

  12. Feasibility of simultaneous PET/MR of the carotid artery

    DEFF Research Database (Denmark)

    Ripa, Rasmus S; Knudsen, Andreas; Hag, Anne Mette F

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of (18)F-FDG. PET/MR was performed a median of 131......) indicating that the luminal (18)F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of (18)F-FDG uptake correlated well between PET/MR and PET...

  13. Proton MR spectroscopy in solitary pulmonary nodules: a preliminary study

    International Nuclear Information System (INIS)

    Yang Chunshan; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Li Shenjiang

    2005-01-01

    Objective: To study the characteristics and the regularities of the metabolites in solitary pulmonary nodules with proton MR spectroscopy, and to investigate the clinical value of MR spectroscopy in differentiating benign from malignant pulmonary nodules. Methods: Sixty-nine patients with solitary pulmonary nodules underwent routine MRI and single-voxel MR spectroscopy using Siemens Vision 1.5 T MR system. MR spectroscopy characteristics and parameters of the metabolites were observed and recorded. Ten pathologic specimens were examined with single-voxel MR spectroscopy. The MR spectroscopy results of the pathologic specimens were compared with those of the solitary pulmonary nodules in vivo. Results: The Cho peak (2.86 ± 1.89) of the malignant nodules was higher than that of the inflammatory (0.87 ± 0.74), tuberculous nodules (0.97 ± 1.09), and hamartoma (0.42 ± 0.53) (P 0.05). Conclusion: MR spectroscopy is reliable in evaluating pulmonary nodules in vivo. The Cho peak, Cho/Cr, and Lac peak of the malignant nodules were higher than those of inflammatory, tuberculous nodules, and hamartoma. MR spectroscopy is helpful in differentiating benign from malignant pulmonary nodules. (authors)

  14. Sacrococcygeal chordoma: MR imaging in 30 patients

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Mi Sook; Chung, Myung Hee [Catholic University of Korea, Holy Family Hospital, Department of Radiology, Pucheon (Korea); Lee, Gyung Kyu; Kang, Heung Sik [Seoul National University Hospital, Department of Radiology, Seoul (Korea); Kwon, Soon Tae [Chungnam University Hospital, Department of Radiology, Taejun (Korea); Park, Jin Gyoon [Chunnam University Hospital, Department of Radiology, Kwangju (Korea); Suh, Jin Suk [Yonsei University, Severans Hospital, Department of Radiology, Seoul (Korea); Cho, Gil Ho [Yeungnam University Hospital, Department of Radiology, Taegu (Korea); Lee, Sung Moon [Kaemyung University Hospital, Department of Radiology, Taeku (Korea); Resnick, Donald [VA Medical Center, Department of Radiology, San Diego, CA (United States)

    2005-02-01

    To evaluate MR imaging of sacrococcygeal chordoma. Thirty patients (age range 22-80 years) underwent MR imaging for the diagnosis and preoperative evaluation of sacrococcygeal chordomas. Eight patients had follow-up MR examination after treatment. The MR images were performed with T1- and T2-weighted imaging, and gadolinium (Gd)-enhanced imaging. The MR images were analyzed for the signal intensity, enhancing pattern, tumor size, growth pattern of the soft tissue component, and tumor extension. T1-weighted images showed low signal masses with foci of high signal intensity in 73% of cases. Tumors enhanced in a variety of patterns after the administration of Gd. Soft tissue masses extending anteriorly were seen in all cases with posterior extension in 77% of cases. The posterior masses involved the surrounding muscles and extended toward the greater sciatic notch, appearing with pseudopodia (87%). Sacroiliac joints were involved in 23% of cases. Four lesions showed intraspinal extension and involvement of the posterior spinal muscles above the level of bony involvement. In 6 patients recurrent tumors were found at or around the surgical margin of the tumor 6 months to 5 years after resection of the sacral tumor. In two of the patients, nodular metastases to the pelvic bones and femur were found 1-4 years after initial examination. In conclusion, MR imaging is useful in the diagnosis and preoperative assessment of sacrococcygeal chordoma. Characteristic findings included sacral mass with heterogeneously high signal intensity with crisscrossing septa on long-repetition-time imaging, well-encapsulated pseudopodia-like or lobulated appearance, and gluteal muscle infiltration. Follow-up MR imaging is helpful to assess for recurrent or metastatic lesions of chordomas. (orig.)

  15. PET/MR imaging of head/neck in the presence of dental implants

    DEFF Research Database (Denmark)

    Ladefoged, Claes; Beyer, Thomas; Keller, Sune

    2013-01-01

    Aim: In combined PET/MR, attenuation correction (AC) is performed indirectly based on the available MR image information. Implant-induced susceptibility artifacts and subsequent signal voids challenge MR-based AC (MR-AC). We evaluate the accuracy of MR-AC in PET/MR in patients with metallic denta...

  16. Interventional MR imaging: state of the art and future perspectives

    International Nuclear Information System (INIS)

    Kahn, T.; Moedder, U.

    1998-01-01

    The concept of MR guidance of invasive diagnostic and minimally invasive therapeutic procedures is based on the excellent morphologic and functional properties of MR imaging. Prerequisites are adequate patient monitoring and adherence to safety guidelines. Fast and ultrafast sequences, temperature quantification, visualization of intravascular devices, thermal stability of contrast media and thermosensitive contrast media are discussed. The spectrum of clinical applications includes biopsies, thermal ablation modalities, vascular applications, MR endoscopy and intraoperative MR imaging. The development of interventional MR imaging is still in its infancy. In the future, MR imaging may play an important role in interventional radiology and minimally invasive therapy. (orig.) [de

  17. MR imaging of cerebral abnormalities in utero.

    Science.gov (United States)

    Thickman, D; Mintz, M; Mennuti, M; Kressel, H Y

    1984-12-01

    In view of the lack of ionizing radiation, ability to image in a variety of planes, and high contrast resolution, magnetic resonance (MR) imaging may have a role in obstetrical management. Three fetuses with severe cerebral abnormalities were studied by MR in utero. The findings were correlated with ultrasound examinations and with autopsy results. Ventricular dilatation and progression of hydrocephalus were detected by MR. Although fetal motion may affect image quality, diagnostically useful images were obtained with imaging times of 2.5 min.

  18. Multi-purpose simulator 'MR TRIOS' for reprocessing plant

    International Nuclear Information System (INIS)

    Mitsui, Takeshi; Ariyoshi, Masahiro

    1993-01-01

    MHI(Mitsubishi Heavy Industries, Ltd.) has developed MR TRIOS(Mitsubishi Reprocessing plant TRansient simulator of Integrated process for Operation Support), the realtime dynamic simulator, for multipurpose use to support the Reprocessing Plant operation in various aspects. MR TRIOS integrates the simulation models of the unit process in reprocessing plant, including shearing, dissolution, NO x absorption, accountability and adjustment and co-decontamination process, where each simulation model has two kinds of models, one is Process and the other is Control System. MR TRIOS can simulate the process behavior of the above listed unit process in an integrated manner as well as independently. It is realized by MR CONTROL, the simulator control program developed by MHI. We can get from MR TRIOS the real-time process values, such as temperature, pressure, density, flow rate and concentration of eminent nuclides etc. enabling the evaluation of the process dynamic characteristics under various operating conditions. MR TRIOS has been proved to be an effective tool for the comprehensive study of the process and system dynamics, for operation technique improvements and for training. In this report we will show the introductory outline of multi-purpose simulator 'MR TRIOS' for reprocessing plant and also show the possibility to clarify the fundamental technical requirement to realize the effective material accountancy measure for Head-end Area. (author)

  19. Radiologic findings of sacroiliitis : emphasis on MR findings

    International Nuclear Information System (INIS)

    Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Soo Young; Park, Jong Ho

    1997-01-01

    To compare the characteristic MR findings of infectious sacroiliitis (IS) and ankylosing spondylitis (AS). We retrospectively reviewed MR findings in eight patients with IS (pyogenic in six, tuberculosis in two) confirmed by culture and clinical follow-up, and in six with AS by HLA-B27 typing. AA control group of 13 asymptomatic volunteers was formed, and they underwent MRI Findings were analysed for morphology, degree of bone erosion, and adjacent soft tissue change. CT findings of AS in four patients and IS in four were also compared to MR findings. MR characteristics of IS included unilaterality (100%), abnormal cartilage signal intensity (100%), bone marrow change (100%), contrast enhancement (100%), erosion (63%), and soft tissue change (63%). MR findings of AS showed bilaterality (67%), abnormal cartilage signal intensity (80%), bone marrow change (80%), erosion (80%), contrast enhancement (44%) and soft tissue change (10%). CT scan showed bony sclerosis and erosion (86%), and abnormal joint space (71%). MR findings of sacroiliitis were loss of thin zone of a cartilage and erosions on T1-weighted image, and increased signal intensity on T2-weighted image. MRI is regarded as a useful diagnostic method where conventional diagnosis is difficult, and is able to image cartilage abnormalities directly and noninvasively. Significant differences in MR findings between IS and AS were not noted, however

  20. Constructing a philosophy of chiropractic: evolving worldviews and modern foundation☆

    Science.gov (United States)

    Senzon, Simon A.

    2011-01-01

    Objective The purpose of this article is to trace the foundations of DD Palmer's sense of self and philosophy of chiropractic to its sources in modern Western philosophy as well as current metatheories about modernity. Discussion DD Palmer's sense of self was indicative of a modern self. A modern self is characterized as a self that developed after the Western Enlightenment and must come to terms with the insights of modernity such as Cartesian dualism, Spinoza's substance, Rousseau's expressivism, and Kant's critiques. It is argued that Palmer's philosophy can be viewed as part of the this tradition alongside his involvement in the 19th century American metaphysical religious culture, which was itself a response to these challenges of the modern self of modernity. Conclusion Palmer's development of chiropractic and its philosophy was a reaction to the challenges and promises of modernity. PMID:22693479