WorldWideScience

Sample records for respiratory system smr

  1. International Cooperation for Creation of Closed System SMR

    Alekseev, P. N.; Kuharkin, N. E.; Stukalov, V.A.; Subbotin, S. A.; Schepetina, T. D.; Udyanskiy, Yu. N.

    2008-01-01

    SMR, there is a set of the projects multi-purpose SMR for technological, for manufacture of heat, electric power and their cogeneration; various modifications of NPP construction (mobile, floating, stationary) are worked. But remains unsolved some more very large complex of problems connected to large-scale use of SMR in civil power. For this purpose it is necessary to execute a complex of basic works including study of structure and organization of 'integral NP structure of Small capacities', where should enter: development system-made elements and their characteristic, namely, relative capacities of manufactures, services for operation and repair, SMR decommissioning, and fuel cycle facilities including RW processing and transmutation (it is an 'internal' part of System) with a choice of necessary technologies for 'System', a choice of reactors types, acceptable in safety, profitability, fuel consumption (elements of an 'external' part of System). It is necessary to note that the majority of the existing now SMR projects can not answer perspective norms and requirements of the future, where these projects are aimed. It is quite definite the place for SMR in power sector exists, an alternative to him it is difficult to find. For the compact large consumers - are intended large power NPP; SMR - for the allocated small consumers. As for independent power sources the requirement only of northern regions of Russia in such SMR makes about 20 GWe. At such places the application of nuclear power sources of small power capacity are possible in complex of independent power-technology facilities - IPTF - 'a cells' manufacturing both electricity, and heat, fresh water, accompanying chemical products from sea water, sea foods, hydrogen for power and technological application etc. Now SMR is considered as one of the most perspective directions in global power the water desalination. Besides the future development of power in the third world countries which have not advanced

  2. Respiratory system

    Bartlett, R. G., Jr.

    1973-01-01

    The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.

  3. Local-Level Prognostics Health Management Systems Framework for Passive AdvSMR Components. Interim Report

    Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Roy, Surajit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hirt, Evelyn H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pardini, Allan F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deibler, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States; Pitman, Stan G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States; Tucker, Joseph C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States; Prowant, Matthew S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States; Suter, Jonathan D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States

    2014-09-12

    This report describes research results to date in support of the integration and demonstration of diagnostics technologies for prototypical AdvSMR passive components (to establish condition indices for monitoring) with model-based prognostics methods. The focus of the PHM methodology and algorithm development in this study is at the localized scale. Multiple localized measurements of material condition (using advanced nondestructive measurement methods), along with available measurements of the stressor environment, enhance the performance of localized diagnostics and prognostics of passive AdvSMR components and systems.

  4. Lungs and Respiratory System

    ... Videos for Educators Search English Español Lungs and Respiratory System KidsHealth / For Parents / Lungs and Respiratory System ... ll have taken at least 600 million breaths. Respiratory System Basics All of this breathing couldn't ...

  5. Integrated Validation System for a Thermal-hydraulic System Code, TASS/SMR-S

    Kim, Hee-Kyung; Kim, Hyungjun; Kim, Soo Hyoung; Hwang, Young-Dong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Hyeon-Soo [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Development including enhancement and modification of thermal-hydraulic system computer code is indispensable to a new reactor, SMART. Usually, a thermal-hydraulic system code validation is achieved by a comparison with the results of corresponding physical effect tests. In the reactor safety field, a similar concept, referred to as separate effect tests has been used for a long time. But there are so many test data for comparison because a lot of separate effect tests and integral effect tests are required for a code validation. It is not easy to a code developer to validate a computer code whenever a code modification is occurred. IVS produces graphs which shown the comparison the code calculation results with the corresponding test results automatically. IVS was developed for a validation of TASS/SMR-S code. The code validation could be achieved by a comparison code calculation results with corresponding test results. This comparison was represented as a graph for convenience. IVS is useful before release a new code version. The code developer can validate code result easily using IVS. Even during code development, IVS could be used for validation of code modification. The code developer could gain a confidence about his code modification easily and fast and could be free from tedious and long validation work. The popular software introduced in IVS supplies better usability and portability.

  6. Avian respiratory system disorders

    Olsen, Glenn H.

    1989-01-01

    Diagnosing and treating respiratory diseases in avian species requires a basic knowledge about the anatomy and physiology of this system in birds. Differences between mammalian and avian respiratory system function, diagnosis, and treatment are highlighted.

  7. Prospects for the SMR Technology

    Tavron, B.; Marouani, D. R.

    2014-01-01

    The nuclear power industry which suffered from prolonged recession has got additional slowdown by the Fukushima nuclear accident. Nuclear safety and security concerns together with cheap fossil fuel alternatives are among main reasons for this recession. Small Modular Reactor (SMR) technologies which feature enhanced safety, security and economics features may restore confidence in nuclear power and lead the nuclear energy renaissance. SMR unit sizes (up to 300MWe), match common existing oil, coal and gas unit sizes and present the environmentally suitable candidate for replacing old polluting plants. Moreover, SMR unit sizes and their enhanced load following capabilities match well future electricity system requirements

  8. TASS/SMR Code Topical Report for SMART Plant, Vol. I: Code Structure, System Models, and Solution Methods

    Chung, Young Jong; Kim, Soo Hyoung; Kim, See Darl (and others)

    2008-10-15

    The TASS/SMR code has been developed with domestic technologies for the safety analysis of the SMART plant which is an integral type pressurized water reactor. It can be applied to the analysis of design basis accidents including non-LOCA (loss of coolant accident) and LOCA of the SMART plant. The TASS/SMR code can be applied to any plant regardless of the structural characteristics of a reactor since the code solves the same governing equations for both the primary and secondary system. The code has been developed to meet the requirements of the safety analysis code. This report describes the overall structure of the TASS/SMR, input processing, and the processes of a steady state and transient calculations. In addition, basic differential equations, finite difference equations, state relationships, and constitutive models are described in the report. First, the conservation equations, a discretization process for numerical analysis, search method for state relationship are described. Then, a core power model, heat transfer models, physical models for various components, and control and trip models are explained.

  9. Doping and respiratory system.

    Casali, L; Pinchi, G; Puxeddu, E

    2007-03-01

    Historically many different drugs have been used to enhance sporting performances. The magic elixir is still elusive and the drugs are still used despite the heavy adverse effects. The respiratory system is regularly involved in this research probably because of its central location in the body with several connections to the cardiovascular system. Moreover people are aware that O2 consumption and its delivery to mitochondria firstly depend on ventilation and on the respiratory exchanges. The second step consists in the tendency to increase V'O2 max and to prolong its availability with the aim of improving the endurance time and to relieve the fatigue. Many methods and substances had been used in order to gain an artificial success. Additional oxygen, autologous and homologous transfusion and erythropoietin, mainly the synthetic type, have been administered with the aim of increasing the amount of oxygen being delivered to the tissues. Some compounds like stimulants and caffeine are endowed of excitatory activity on the CNS and stimulate pulmonary ventilation. They did not prove to have any real activity in supporting the athletic performances. Beta-adrenergic drugs, particularly clenbuterol, when administered orally or parenterally develop a clear illicit activity on the myosin fibres and on the muscles as a whole. Salbutamol, terbutaline, salmeterol and formoterol are legally admitted when administrated by MDI in the treatment of asthma. The prevalence of asthma and bronchial hyperactivity is higher in athletes than amongst the general population. This implies that clear rules must be provided to set a correct diagnosis of asthma in the athletes and a correct therapy to align with the actual guidelines according to the same rights of the "other" asthmatic patients.

  10. THERMAL-HYDRAULIC ANALYSIS OF SMR WITH NATURALLY CIRCULATING PRIMARY SYSTEM DURING LOSS OF FEED WATER ACCIDENT

    Susyadi Susyadi

    2016-09-01

    ABSTRAK Reaktor daya kecil modular (SMR memiliki beberapa keunggulan dibanding reaktor daya besar konvensional. Dengan disain yang lebih sederhana dan terintegrasi, penerapan hukum alamiah untuk sistem keselamatannya dan biaya modal yang rendah, reaktor ini sangat cocok untuk dibangun di Indonesia. Salah satunya disain SMR yang sedang dikembangkan menerapkan gaya penggerak alami untuk sistim pendingin primernya. Dengan disain seperti itu, adalah sangat penting untuk memahami implikasinya terhadap aspek keselamatan pada seluruh kondisi operasi. Salah satu yang perlu diinvestigasi adalah kecelakaan kehilangan air umpan (LoFW. Pada studi ini, dilakukan analisis kinerja thermal hidrolik SMR yang menggunakan sistim pendinginan primer sirkulasi alam saat kecelakaan LoFW. Tujuannya adalah untuk menginvestigasi karakteristik aliran sistem primer saat kecelakaan LoFW dan untuk memastikan apakah aliran sirkulasi alam cukup untuk memindahkan panas dari teras guna menjaga kondisi tetap aman selama kecelakaan tersebut. Metoda yang digunakan adalah dengan merepresentasikan sistem reaktor ke dalam model-model generik program RELAP5 dan melakukan simulasi numerik. Hasil perhitungan menunjukkan bahwa setelah kejadian pemicu dan trip reaktor, pada sisi primer laju alirnya berfluktuasi secara signifikan dan temperatur pendinginnya menurun secara bertahap sedangkan  pada sisi sekunder kondisi uap berubah menjadi uap jenuh. Laju alir turun dari ~711 kg/detik menjadi ~263 kg/detik sebelum kembali naik lagi pada t=~46 detik. Saat laju alir di titik terendah, temperatur pusat bahan bakar dan fluida pendingin adalah sekitar  ~565 K dan  ~554 K, yang menujukkan bahwa temperatur bahan bakar masih jauh di bawah batas disain dan temperatur fluidanya juga berada di bawah titik saturasi. Keadaan ini menunjukkan bahwa saat transien kedua parameter utama termohidrolik reaktor tetap dalam kondisi yang dapat diterima sehingga dapat disimpulkan  bahwa saat  kecelakaan kehilangan air umpan, SMR

  11. Assessment of passive safety system of a Small Modular Reactor (SMR)

    Butt, Hassan Nawaz; Ilyas, Muhammad; Ahmad, Masroor; Aydogan, Fatih

    2016-01-01

    Highlights: • The MASLWR test facility has been modeled in RELAP5-SCDAP. The model is validated by comparing the simulation results with the experimental data. • Results obtained from various transients show that high pressure vent and sump recirculation lines provide natural circulation flow path for long term cooling of core. • New scenarios are considered in which the effect of vent and sump recirculation valves failure has been investigated. • It is found from the results that continuous loss of inventory occurs due to lack of recirculation. • It is concluded that the high pressure vent valves in the MASLWR safety system require more redundancy. - Abstract: Innovative SMRs are designed with enhanced safety features based on lessons learnt from past experience of plant operation. Reliance on natural circulation and addition of passive safety systems made them inherently safe and simple in design. It is required to study reliability assessment of passive safety systems during postulated transients prior to their deployment on commercial scale. Test facilities and best estimate system codes are playing significant role in assessment of passive safety systems as well as in design, certification and evaluation of these innovative types of reactors. RELAP5 code is widely used for thermal-hydraulic analysis of nuclear reactors. In this work, the passive safety systems of Multi-Application Small Light Water (MASLWR) have been assessed. The complete loop of the MASLWR test facility has been modeled in RELAP5-SCDAP Mod 4.0. The RELAP5 model is validated by comparing the simulation results with the experimental data. Results obtained for various transients show that high pressure vent and sump recirculation lines provide natural circulation flow path for long term cooling of core to avoid core heat up. Some of the components of passive safety system of MASLWR still rely on active power. Therefore, it was necessary to investigate their performance under failure

  12. Thermal hydraulic model descrition of TASS/SMR

    Yoon, Han Young; Kim, H. C.; Chung, Y. J.; Lim, H. S.; Yang, S. H

    2001-04-01

    The TASS/SMR code has been developed for the safety analysis of SMART. The governing equations were applied only to the primary coolant system in TASS which had been developed at KAERI. In TASS/SMR, the solution method is improved so that the primary and secondary coolant systems are solved simultaneously. Besides the solution method, thermal-hydraulic models are incorporated, in TASS/SMR, such as non-condensible gas model, helical steam generator heat transfer model, and passive residual heat removal system (PRHRS) heat transfer model for the application to SMART. The governing equtions of TASS/SMR are based on the drift-flux model so that the accidents and transients accompaning with two-phase flow can be analized. This report describes the governing equations and solution methods used in TASS/SMR and also includes the description for the thermal hydraulic models for SMART design.

  13. Respiratory care management information systems.

    Ford, Richard M

    2004-04-01

    Hospital-wide computerized information systems evolved from the need to capture patient information and perform billing and other financial functions. These systems, however, have fallen short of meeting the needs of respiratory care departments regarding work load assessment, productivity management, and the level of outcome reporting required to support programs such as patient-driven protocols. The respiratory care management information systems (RCMIS) of today offer many advantages over paper-based systems and hospital-wide computer systems. RCMIS are designed to facilitate functions specific to respiratory care, including assessing work demand, assigning and tracking resources, charting, billing, and reporting results. RCMIS incorporate mobile, point-of-care charting and are highly configurable to meet the specific needs of individual respiratory care departments. Important and substantial benefits can be realized with an RCMIS and mobile, wireless charting devices. The initial and ongoing costs of an RCMIS are justified by increased charge capture and reduced costs, by way of improved productivity and efficiency. It is not unusual to recover the total cost of an RCMIS within the first year of its operation. In addition, such systems can facilitate and monitor patient-care protocols and help to efficiently manage the vast amounts of information encountered during the practitioner's workday. Respiratory care departments that invest in RCMIS have an advantage in the provision of quality care and in reducing expenses. A centralized respiratory therapy department with an RCMIS is the most efficient and cost-effective way to monitor work demand and manage the hospital-wide allocation of respiratory care services.

  14. Westinghouse Small Modular Reactor (SMR) Programe

    Shulyak, Nick

    2014-01-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) in which all primarycomponents associated with the nuclear steam supply system, including the steam generator and the pressurizer, are housed within the reactor vessel. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. This paper describes the design and functionality of the Westinghouse SMR, the key drivers influencing the design of the Westinghouse SMR and the unique passive safety features of the Westinghouse SMR. Several critical motivators contributed to the development and integration of the Westinghouse SMR design. These design drivers include safety, economics, reactor expertise and experience, research and development requirements, functionality of systems and components, size of the systems and vessels, simplicity of design, and licensing requirements. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000 reactor, and provides mitigation of all design basis accidents without the need for offsite AC electrical power for a period of seven days. The economics of the Westinghouse SMR challenges the established approach of large Light Water Reactors (LWR) that utilized the economies of scale to reach economic competiveness. To serve the market expectation of smaller capital investment and cost competitive energy, a modular design approach is implemented within the Westinghouse SMR. The Westinghouse SMR building layout integrates the three basic design constraints of modularization; transportation, handling and module-joining technology. The integral Westinghouse SMR design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high

  15. Supply strategy for SMR deployment

    Coccagna, A.F.

    2013-01-01

    This document provides a description of Babcock and Wilcox's deployment strategy for the mPower™ Small Modular Reactor from the perspective of Supply Chain and Manufacturing. A desirable future state of readiness is described as one which leverages and revitalizes an existing supply chain and manufacturing infrastructure, as well as leveraging an existing workforce of engineering, construction, and project management employees. B and W's mPower™ SMR value proposition offers many desired design and operating advantages to the SMR market. (author)

  16. Respiratory guiding system for respiratory motion management in respiratory gated radiotherapy

    Kang, Seong Hee; Kim, Dong Su; Kim, Tae Ho; Suh, Tae Suk

    2013-01-01

    Respiratory guiding systems have been shown to improve the respiratory regularity. This, in turn, improves the efficiency of synchronized moving aperture radiation therapy, and it reduces the artifacts caused by irregular breathing in imaging techniques such as four-dimensional computed tomography (4D CT), which is used for treatment planning in RGRT. We have previously developed a respiratory guiding system that incorporates an individual-specific guiding waveform, which is easy to follow for each volunteer, to improve the respiratory regularity. The present study evaluates the application of this system to improve the respiratory regularity for respiratory-gated radiation therapy (RGRT). In this study, we evaluated the effectiveness of an in-house-developed respiratory guiding system incorporating an individual specific guiding waveform to improve the respiratory regularity for RGRT. Most volunteers showed significantly less residual motion at each phase during guided breathing owing to the improvement in respiratory regularity. Therefore, the respiratory guiding system can clearly reduce the residual, or respiratory, motion in each phase. From the result, the CTV and the PTV margins during RGRT can be reduced by using the respiratory guiding system, which reduces the residual motions, thus improving the accuracy of RGRT

  17. Respiratory

    The words "respiratory" and "respiration" refer to the lungs and breathing. ... Boron WF. Organization of the respiratory system. In: Boron WF, Boulpaep EL, eds. Medical Physiology . 3rd ed. Philadelphia, PA: Elsevier; 2017:chap 26.

  18. Effects of Aging on the Respiratory System.

    Levitzky, Michael G.

    1984-01-01

    Relates alterations in respiratory system functions occurring with aging to changes in respiratory system structure during the course of life. Main alterations noted include loss of alveolar elastic recoil, alteration in chest wall structure and decreased respiratory muscle strength, and loss of surface area and changes in pulmonary circulation.…

  19. Respiratory analysis system and method

    Liu, F. F. (Inventor)

    1973-01-01

    A system is described for monitoring the respiratory process in which the gas flow rate and the frequency of respiration and expiration cycles can be determined on a real time basis. A face mask is provided with one-way inlet and outlet valves where the gas flow is through independent flowmeters and through a mass spectrometer. The opening and closing of a valve operates an electrical switch, and the combination of the two switches produces a low frequency electrical signal of the respiratory inhalation and exhalation cycles. During the time a switch is operated, the corresponsing flowmeter produces electric pulses representative of the flow rate; the electrical pulses being at a higher frequency than that of the breathing cycle and combined with the low frequency signal. The high frequency pulses are supplied to conventional analyzer computer which also receives temperature and pressure inputs and computes mass flow rate and totalized mass flow of gas. From the mass spectrometer, components of the gas are separately computed as to flow rate. The electrical switches cause operation of up-down inputs of a reversible counter. The respective up and down cycles can be individually monitored and combined for various respiratory measurements.

  20. Challenges of SMR licensing practices

    Soderholm, K., E-mail: kristiina.soderholm@fortum.com [Fortum Power, Espoo (Finland)

    2012-12-15

    This paper aims to increase the understanding of high level Nuclear Power Plant (NPP) licensing processes in Finland, France, the UK, Canada and the USA. These countries have been selected for this study because of their different licensing processes and recent actions in new NPP construction. After discussing their similarities and differences, suitable features for Small Modular Reactor licensing can be emphasized and suggested. Some of the studied licensing processes have elements that are already quite well suited for application to SMRs, but all of these different national processes can benefit from studying and implementing lessons learned from SMR specific licensing needs. The main SMR features to take into account in licensing are standardization of the design, modularity, mass production and serial construction. Modularity can be divided into two different categories: the first category is simply a single unit facility constructed of independently engineered modules (e.g., construction process for Westinghouse AP-1000 NPP) and the second is a facility structure composed of many reactor modules where modules are manufactured in factories and installed into the facility as needed (e.g., NuScale Power SMR design). Short construction schedules will not be fully benefited from if the long licensing process prolongs the commissioning and approach to full-power operation. The focus area of this study is to better understand the possibility of SMR deployment in small nuclear countries, such as Finland, which currently has four operating NPPs. The licensing process needs to be simple and clear to make SMR deployment feasible from an economical point of view. This paper uses public information and interviews with experts to establish the overview of the different licensing processes and their main steps. A high-level comparison of the licensing steps has been carried out. Certain aspects of the aviation industry licensing process have also been studied and certain

  1. The respiratory system in equations

    Maury, Bertrand

    2013-01-01

    The book proposes an introduction to the mathematical modeling of the respiratory system. A detailed introduction on the physiological aspects makes it accessible to a large audience without any prior knowledge on the lung. Different levels of description are proposed, from the lumped models with a small number of parameters (Ordinary Differential Equations), up to infinite dimensional models based on Partial Differential Equations. Besides these two types of differential equations, two chapters are dedicated to resistive networks, and to the way they can be used to investigate the dependence of the resistance of the lung upon geometrical characteristics. The theoretical analysis of the various models is provided, together with state-of-the-art techniques to compute approximate solutions, allowing comparisons with experimental measurements. The book contains several exercises, most of which are accessible to advanced undergraduate students.

  2. Recent trends of SMR developments in USA

    Kang, Han Ok

    2011-11-01

    Recently several nuclear reactor vendors from the United States officially announced the development and construction plans for the Small and Modular Reactors (SMR). NuScale Power completed a preliminary plant design and intends to submit a design certification application to the NRC next year. Babcock and Wilcox is developing the mPower reactor, which has the capacity to provide 125 MWe to 750 MWe or more for a 4.5-year operating cycle without refueling, with its scalable and modular design. Recently Westinghouse has officially introduced new 200 MWe Small Modular Reactor (SMR) for the US Department of Energy's demonstration program. The SMART reactor is an advanced integral type reactor with a power of 330MWt. A passive residual heat removal system (PRHRS) is also installed to prevent over-heating and over-pressurization of the primary system during accidental conditions. Safety injection system for the SBLOCA and containment spray system for the containment cooling and precipitation of radioactive material are based on the active systems of conventional nuclear plant. Reliance on the active systems for the safety function lowers public acceptance and makes the SMART less competitive with other SMRs developed in the United States. Two approaches are suggested to solve this problem. The first approach is the passive safety system on the basis of the steel safeguard vessel and the second is on the basis of concrete containment

  3. Auscultation of the respiratory system

    Sarkar, Malay; Madabhavi, Irappa; Niranjan, Narasimhalu; Dogra, Megha

    2015-01-01

    Auscultation of the lung is an important part of the respiratory examination and is helpful in diagnosing various respiratory disorders. Auscultation assesses airflow through the trachea-bronchial tree. It is important to distinguish normal respiratory sounds from abnormal ones for example crackles, wheezes, and pleural rub in order to make correct diagnosis. It is necessary to understand the underlying pathophysiology of various lung sounds generation for better understanding of disease processes. Bedside teaching should be strengthened in order to avoid erosion in this age old procedure in the era of technological explosion. PMID:26229557

  4. Auscultation of the respiratory system

    Malay Sarkar

    2015-01-01

    Full Text Available Auscultation of the lung is an important part of the respiratory examination and is helpful in diagnosing various respiratory disorders. Auscultation assesses airflow through the trachea-bronchial tree. It is important to distinguish normal respiratory sounds from abnormal ones for example crackles, wheezes, and pleural rub in order to make correct diagnosis. It is necessary to understand the underlying pathophysiology of various lung sounds generation for better understanding of disease processes. Bedside teaching should be strengthened in order to avoid erosion in this age old procedure in the era of technological explosion.

  5. Systems dynamics (SD) strategy for Small Modular Reactor (SMR) marketing - Conquest at the MIT Energy Laboratory (Pres. MIT Energy Initiative)

    Woo, T. H. [Yonsei University, Wonju (Korea, Republic of)

    2016-10-15

    This reactor has the specification as the power is 330 MWt pressurized water reactor (PWR) with integral steam generators and advanced safety features. In the plant design, it is planned for electricity generation of 100 MWe and thermal applications of seawater desalination where the life span is a 60-year operation design and three-year refueling cycle. Regarding of the licensing, the standard design was approved from the Korean regulator in mid-2012 and the Korea Atomic Energy Research Institute (KAERI) has a plan to build a demonstration plant to operate from 2017. According to the previous study of the marketing strategy of the Canadian small reactor, Safe LOW-POwer Kritical Experiment (SLOWPOKE) reactor had been investigated in 1988. Therefore, it is interesting to compare SMART and SLOWPOKE. In this work, it is to find out the strategy of the successful marketing of SMART and suggest continuous marketing prospects. There are specifications and parameters of SMART in Tables 1 and 2. The public acceptance (PA) had been studies as safety-public interpretation, SLOWPOKE safety-experience and process, and economics in the previous paper of the SLOWPOKE, which was about the marketing strategy for the commercial nuclear reactor. The highly cognitive networking based dynamical modeling was discussed where the system is treated by a complex and non-linear way. The linear networking of the interested issue was changed by the SD algorithm where the feedback and multiple connections are added to the original networking theory. The non-linear method has shown the complexity of the marketing strategy, especially for the NPP which is the very expensive and safety focused facility.

  6. Systems dynamics (SD) strategy for Small Modular Reactor (SMR) marketing - Conquest at the MIT Energy Laboratory (Pres. MIT Energy Initiative)

    Woo, T. H.

    2016-01-01

    This reactor has the specification as the power is 330 MWt pressurized water reactor (PWR) with integral steam generators and advanced safety features. In the plant design, it is planned for electricity generation of 100 MWe and thermal applications of seawater desalination where the life span is a 60-year operation design and three-year refueling cycle. Regarding of the licensing, the standard design was approved from the Korean regulator in mid-2012 and the Korea Atomic Energy Research Institute (KAERI) has a plan to build a demonstration plant to operate from 2017. According to the previous study of the marketing strategy of the Canadian small reactor, Safe LOW-POwer Kritical Experiment (SLOWPOKE) reactor had been investigated in 1988. Therefore, it is interesting to compare SMART and SLOWPOKE. In this work, it is to find out the strategy of the successful marketing of SMART and suggest continuous marketing prospects. There are specifications and parameters of SMART in Tables 1 and 2. The public acceptance (PA) had been studies as safety-public interpretation, SLOWPOKE safety-experience and process, and economics in the previous paper of the SLOWPOKE, which was about the marketing strategy for the commercial nuclear reactor. The highly cognitive networking based dynamical modeling was discussed where the system is treated by a complex and non-linear way. The linear networking of the interested issue was changed by the SD algorithm where the feedback and multiple connections are added to the original networking theory. The non-linear method has shown the complexity of the marketing strategy, especially for the NPP which is the very expensive and safety focused facility

  7. Investigations of respiratory control systems simulation

    Gallagher, R. R.

    1973-01-01

    The Grodins' respiratory control model was investigated and it was determined that the following modifications were necessary before the model would be adaptable for current research efforts: (1) the controller equation must be modified to allow for integration of the respiratory system model with other physiological systems; (2) the system must be more closely correlated to the salient physiological functionings; (3) the respiratory frequency and the heart rate should be expanded to illustrate other physiological relationships and dependencies; and (4) the model should be adapted to particular individuals through a better defined set of initial parameter values in addition to relating these parameter values to the desired environmental conditions. Several of Milhorn's respiratory control models were also investigated in hopes of using some of their features as modifications for Grodins' model.

  8. Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

    Gallagher, R. R.

    1974-01-01

    The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

  9. Applicability of TASS/SMR using drift flux model for SMART LOCA analysis

    Chung, Young-Jong, E-mail: chung@kaeri.re.kr; Kim, Soo Hyung; Lee, Gyu Hyeung; Lee, Won Jae

    2013-09-15

    Highlights: • SMART plant and TASS/SMR code have been developed by KAERI. • TASS/SMR code adopts a drift flux model to consider relative velocity under two-phase condition. • Drift flux model in TASS/SMR is validated using separate effect test results. • Applicability of TASS/SMR using drift flux model for SMART LOCA analysis is confirmed. -- Abstract: Small reactors can apply to local power demands or remote areas. SMART, which can produce 90 MWe of electricity and 40,000 tons/day of sea-water desalination for a 100,000 population city, is a promising advanced integral type small reactor. The thermal hydraulic analysis code with a drift flux model, TASS/SMR, was developed for a conservative simulation of a small break loss of coolant accident in SMART. Taking into account SMART-specific inherent characteristics, the code adopts the Chexal–Lellouche correlation for a drift flux model. The capability of TASS/SMR code is validated using the results of the experimental data. The code predicts conservatively the void distribution compared with the experimental data. TASS/SMR calculation predicts reasonably major phenomena for the SBLOCA and is more conservative than or nearly the same as the results of the best estimated realistic system code, MARS. TASS/SMR code can be used for a SBLOCA analysis of SMART.

  10. Applicability of TASS/SMR using drift flux model for SMART LOCA analysis

    Chung, Young-Jong; Kim, Soo Hyung; Lee, Gyu Hyeung; Lee, Won Jae

    2013-01-01

    Highlights: • SMART plant and TASS/SMR code have been developed by KAERI. • TASS/SMR code adopts a drift flux model to consider relative velocity under two-phase condition. • Drift flux model in TASS/SMR is validated using separate effect test results. • Applicability of TASS/SMR using drift flux model for SMART LOCA analysis is confirmed. -- Abstract: Small reactors can apply to local power demands or remote areas. SMART, which can produce 90 MWe of electricity and 40,000 tons/day of sea-water desalination for a 100,000 population city, is a promising advanced integral type small reactor. The thermal hydraulic analysis code with a drift flux model, TASS/SMR, was developed for a conservative simulation of a small break loss of coolant accident in SMART. Taking into account SMART-specific inherent characteristics, the code adopts the Chexal–Lellouche correlation for a drift flux model. The capability of TASS/SMR code is validated using the results of the experimental data. The code predicts conservatively the void distribution compared with the experimental data. TASS/SMR calculation predicts reasonably major phenomena for the SBLOCA and is more conservative than or nearly the same as the results of the best estimated realistic system code, MARS. TASS/SMR code can be used for a SBLOCA analysis of SMART

  11. Dynamics of human respiratory system mycoflora

    Anna Biedunkiewicz

    2014-08-01

    Full Text Available The study aimed at determing the prevalence of individual species of fungi in the respiratory systems of women and men, analysis of the dynamics of the fungi in individual sections of the respiratory system as concerns their quantity and identification of phenology of the isolated fungi coupled with an attempt at identifying their possible preferences for appearing during specific seasons of thc year. During 10 years of studies (1989- 1998. 29 species of fungi belonging: Candida, Geolrichum, Saccharomyces, Saccharomycopsis, Schizosaccharomyces, Torulopsis, Trichosporon and Aspergillus were isolated from the ontocenoses of the respiratory systems of patients at the Independent Public Center for Pulmonology and Oncology in Olsztyn. Candida albicans was a clearly dominating fungus. Individual species appeared individually, in twos or threes in a single patient, they were isolated more frequently in the spring and autumn, less frequently during the winter and summer. The largest number of fungi species were isolated from sputum (29 species, bronchoscopic material (23 species and pharyngeal swabs (15 species. Sacchoromycopsis capsularis and Trichosporon beigelii should be treated as new for the respiratory system. Biodiversity of fungi, their numbers and continous fluctuations in frequency indicate that the respiratory system ontocenose offers the optimum conditions for growth and development of the majority of the majority of yeasts - like fungi.

  12. Canada puts emphasis on SMR

    Anon.

    2017-01-01

    Thanks to hydroelectricity and 16% share of nuclear power, Canada is among the few countries to respect GIEC's 2050 climate objectives: producing 80% of electricity without emitting CO 2 . In the context of a growing power demand, Canada has integrated nuclear energy in its energy scenarios. Small Modular Reactors (SMR) are considered as an efficient means to replace diesel generators used in small isolated communities. Several North America start-ups such as Terrestrial Energy that develops molten salt reactors, have moved to Canada. The British firm Moltex has chosen Canadian Nuclear Safety Authority (CCSN for the certification of its 4. generation reactor. In Ontario, Canada's most populated province, nuclear energy produces 60% of its electricity consumption and has allowed the progressive shutdown of all coal-fed power plants of the province. Between 2000 and 2013 nuclear power increased by 20% whereas the coal share in power production dropped by 27%. The 2014 Toronto Public Health report highlights that since 2004 premature mortality has dropped by 23% and the hospitalization due to air pollution by 41%. (A.C.)

  13. Respiratory system. Part 2: Gaseous exchange.

    McLafferty, Ella; Johnstone, Carolyn; Hendry, Charles; Farley, Alistair

    This article, which isthe last in the life sciences series and the second of two articles on the respiratory system, describes gaseous exchange in the lungs, transport of oxygen and carbon dioxide, and internal and external respiration. The article concludes with a brief consideration of two conditions that affect gas exchange and transport: carbon monoxide poisoning and chronic obstructive pulmonary disease.

  14. Endocan and the respiratory system: a review

    Kechagia M

    2016-12-01

    Full Text Available Maria Kechagia,1,2 Ioannis Papassotiriou,2 Konstantinos I Gourgoulianis1 1Respiratory Medicine Department, University of Thessaly Medical School, Larissa, 2Department of Clinical Biochemistry, Aghia Sophia Children’s Hospital, Athens, Greece Abstract: Endocan, formerly called endothelial cell-specific molecule 1, is an endothelial cell-associated proteoglycan that is preferentially expressed by renal and pulmonary endothelium. It is upregulated by proangiogenic molecules as well as by pro-inflammatory cytokines, and since it reflects endothelial activation and dysfunction, it is regarded as a novel tissue and blood-based relevant biomarker. As such, it is increasingly being researched and evaluated in a wide spectrum of healthy and disease pathophysiological processes. Here, we review the present scientific knowledge on endocan, with emphasis on the evidence that underlines its possible clinical value as a prognostic marker in several malignant, inflammatory and obstructive disorders of the respiratory system. Keywords: endocan, endothelial dysfunction, inflammation, respiratory disorders

  15. Opportunities in SMR Emergency Planning

    Moe, Wayne L. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Advanced Reactor Technologies Program

    2014-10-01

    Using year 2014 cost information gathered from twenty different locations within the current commercial nuclear power station fleet, an assessment was performed concerning compliance costs associated with the offsite emergency Planning Standards contained in 10 CFR 50.47(b). The study was conducted to quantitatively determine the potential cost benefits realized if an emergency planning zone (EPZ) were reduced in size according to the lowered risks expected to accompany small modular reactors (SMR). Licensees are required to provide a technical basis when proposing to reduce the surrounding EPZ size to less than the 10 mile plume exposure and 50 mile ingestion pathway distances currently being used. To assist licensees in assessing the savings that might be associated with such an action, this study established offsite emergency planning costs in connection with four discrete EPZ boundary distances, i.e., site boundary, 2 miles, 5 miles and 10 miles. The boundary selected by the licensee would be based on where EPA Protective Action Guidelines are no longer likely to be exceeded. Additional consideration was directed towards costs associated with reducing the 50 mile ingestion pathway EPZ. The assessment methodology consisted of gathering actual capital costs and annual operating and maintenance costs for offsite emergency planning programs at the surveyed sites, partitioning them according to key predictive factors, and allocating those portions to individual emergency Planning Standards as a function of EPZ size. Two techniques, an offsite population-based approach and an area-based approach, were then employed to calculate the scaling factors which enabled cost projections as a function of EPZ size. Site-specific factors that influenced source data costs, such as the effects of supplemental funding to external state and local agencies for offsite response organization activities, were incorporated into the analysis to the extent those factors could be

  16. Safety and international development of small modular reactors (SMR). A study of GRS

    Buchholz, Sebastian; Kruessenberg, Anne; Schaffrath, Andreas [Gesellschaft fuer Anlagen- und Reaktorsicherheit mbH (GRS), Garching (Germany). Bereich Reaktorsicherheitsforschung

    2015-11-15

    The abbreviation SMR stands for Small Modular Reactor and describes reactors with low power output. One reactor module, composed of primary, secondary and, where necessary, intermediate circuit and auxiliary systems, may be transported to the construction site as a whole or in few parts only and can therefore be connected quickly to the grid. Various modules can form a larger nuclear power plant and additional modules may be added one by one, while the others are in operation. Designers develop SMR for the deployment mainly in remote, sparsely populated areas or near cities respectively. SMR may provide in both cases electricity, district heating and potable water.

  17. Quality Assurance for Thermal Hydraulic Analysis Code, TASS/SMR-S

    Kim, Hee Kyung; Kim, Soo Hyoung; Chung, Young Jong; Kim, Hyeon Soo

    2012-01-01

    Safety analysis for a System-integrated Modular Advanced Reactor (SMART), a computer code called TASS/SMR-S has been developed by Korea Atomic Energy Research Institute (KAERI). To guarantee the quality of the software, a series of software Quality Assurance (QA) procedures has been developed for the TASS/SMR-S code. These procedures are described herein, from the requirement phase to the Verification and Validation (V and V) phase, and representative results of the TASS/SMR-S QA are presented

  18. Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure

    Kneyber, Martin C. J.; van Heerde, Marc; Twisk, Jos W. R.; Plotz, Frans B.; Markhors, Dick G.

    2009-01-01

    Introduction Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of

  19. Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure

    Kneijber, M.C.J.; van Heerde, M.; Twisk, J.W.R.; Plotz, F.; Markhorst, D.G.

    2009-01-01

    Introduction: Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of

  20. Evaluation of the new respiratory gating system

    Shi, Chengyu; Tang, Xiaoli; Chan, Maria

    2018-01-01

    Objective The newly released Respiratory Gating for Scanners (RGSC; Varian Medical Systems, Palo Alto, CA, USA) system has limited existing quality assurance (QA) protocols and pertinent publications. Herein, we report our experiences of the RGSC system acceptance and QA. Methods The RGSC system integration was tested with peripheral equipment, spatial reproducibility, and dynamic localization accuracy for regular and irregular breathing patterns, respectively. A QUASAR Respiratory Motion Phantom and a mathematical fitting method were used for data acquisition and analysis. Results The results showed that the RGSC system could accurately measure regular motion periods of 3–10 s. For irregular breathing patterns, differences from the existing Real-time Position Management (RPM; Varian Medical Systems, Palo Alto, CA) system were observed. For dynamic localization measurements, the RGSC system showed 76% agreement with the programmed test data within ±5% tolerance in terms of fitting period. As s comparison, the RPM system showed 66% agreement within ±5% tolerance, and 65% for the RGSC versus RPM measurements. Conclusions New functions and positioning accuracy improve the RGSC system’s ability to achieve higher dynamic treatment precision. A 4D phantom is helpful for the QA tests. Further investigation is required for the whole RGSC system performance QA. PMID:29722356

  1. Restructuring of the driver for TASS/SMR, SMART analysis code

    Lee, G. H.; Kim, S. H.; Whang, Y. D.; Kim, H. C.

    2003-01-01

    TASS/SMR is under development by implementing the newly developed thermal hydraulic models for the integral reactor, SMART. The data structure of TASS utilizes external files, which could result in difficulties for the code maintenance and an easy understanding of the code. The driver for TASS/SMR was rewritten for the use of Fortran 90 advanced features, such as dynamic memory management and user defined derived type. The input structure of TASS changed from the interactive method to card numbered system. Also the output process of TASS reformed by removing the utility program. The validation of the TASS/SMR driver was performed by the comparison of results. The use of the revised TASS/SMR driver is expected to accelerate code development process as well as improve user friendliness

  2. Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy

    Lee, Yeong Cheol; Kim, Sun Myung; Do, Gyeong Min; Park, Geun Yong; Kim, Gun Oh; Kim, Young Bum [Dept. of Radiation Oncology, Guro Hospital, Korea Univeristy, Seoul (Korea, Republic of)

    2012-09-15

    The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded after the therapy. The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory

  3. Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy

    Lee, Yeong Cheol; Kim, Sun Myung; Do, Gyeong Min; Park, Geun Yong; Kim, Gun Oh; Kim, Young Bum

    2012-01-01

    The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded after the therapy. The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance

  4. Parametric evaluation of an SMR design domain

    Al Rashdan, Ahmad; Tsvetkov, Pavel

    2015-01-01

    Highlights: • The design of nuclear reactors involves a large set of highly coupled variables. • The effects of 14 variables on 6 SMR performance characteristics was researched. • Screening and sensitivity analyses were applied to decouple the variables’ effects. • Significantly simpler system models were generated, enabling simple optimization. - Abstract: The complex and coupled behavior of the variables that affect the currently developing generation IV reactors and the increase of interest in Small Modular Reactors are major incentives to seek efficient design methods. Instead of the brute force design methodology, often applied to the analysis of nuclear reactors, other more economical and systematic methods should be applied. In a complex system with a high number of variables, it often is necessary to develop models to describe the behavior of each performance characteristic with respect to a set of variables and their interactions. If expensive experiments are needed to develop these models, the number of experiments should be minimized. This can be achieved by designing the experiments to be performed. Once the system’s models are developed, they can be used to decouple the variables’ effects on the performance characteristics and simplify the optimization process. In this article, three screening and sensitivity analysis methods are applied to decouple and understand the effects of fourteen variables on six performance characteristics of a Small Modular Reactor’s design, based on the Advanced Passive (AP-1000) reactor. The application of these methods facilitated the determination of the most important parameters of each performance characteristic, and resulted in several distinctive findings. These findings are applicable to any Light Water Small Modular Reactor that falls within the variables’ design domain

  5. Respiratory Effects and Systemic Stress Response Following ...

    Previous studies have demonstrated that exposure to the pulmonary irritant ozone causes myriad systemic metabolic and pulmonary effects attributed to sympathetic and hypothalamus-pituitary-adrenal (HPA) axis activation, which are exacerbated in metabolically impaired models. We examined respiratory and systemic effects following exposure to a sensory irritant acrolein to elucidate the systemic and pulmonary consequences in healthy and diabetic rat models. Male Wistar and Goto Kakizaki (GK) rats, a nonobese type II diabetic Wistar-derived model, were exposed by inhalation to 0, 2, or 4 ppm acrolein, 4 h/d for 1 or 2 days. Exposure at 4 ppm significantly increased pulmonary and nasal inflammation in both strains with vascular protein leakage occurring only in the nose. Acrolein exposure (4 ppm) also caused metabolic impairment by inducing hyperglycemia and glucose intolerance (GK > Wistar). Serum total cholesterol (GKs only), low-density lipoprotein (LDL) cholesterol (both strains), and free fatty acids (GK > Wistar) levels increased; however, no acrolein-induced changes were noted in branched-chain amino acid or insulin levels. These responses corresponded with a significant increase in corticosterone and modest but insignificant increases in adrenaline in both strains, suggesting activation of the HPA axis. Collectively, these data demonstrate that acrolein exposure has a profound effect on nasal and pulmonary inflammation, as well as glucose and lipid metabolis

  6. Respiratory Effects and Systemic Stress Response Following ...

    Previous studies have demonstrated that exposure to ozone, a pulmonary irritant, causes myriad systemic metabolic and pulmonary effects that are attributed to neuronal and hypothalamus-pituitary-adrenal (HPA) axis activation, which are exacerbated in metabolically-impaired models. In order to elucidate the systemic consequences and the contribution of the HPA axis in mediating metabolic and respiratory effects of acrolein, a sensory irritant, we examined pulmonary, nasal, and systemic effects in rats following exposure. Male, 10 week old Wistar and Goto Kakizaki (GK) rats, a non-obese type II diabetic Wistar-derived model, were exposed to 0, 2 or 4 ppm acrolein, 4h/day for 1 or 2 days. Acrolein exposure at 4 ppm significantly increased pulmonary and nasal damage in both strains as demonstrated by increased inspiratory and expiratory times indicating labored breathing, elevated biomarkers of injury, and neutrophilic inflammation. Overall, at both time points acrolein exposure caused noticeably more damage in the nasal passages as opposed to the lung with vascular protein leakage occurring only in the nose. Acrolein exposure (4 ppm) also led to metabolic impairment by inducing hyperglycemia and glucose intolerance (GK>Wistar) as indicated by glucose tolerance testing. In addition, serum total cholesterol (GKs only), LDL cholesterol (both strains), and free fatty acids (GK>Wistar) levels increased; however, no acrolein-induced changes were noted in branched-c

  7. Respiratory system mechanics during laparoscopic cholecystectomy.

    Rizzotti, L; Vassiliou, M; Amygdalou, A; Psarakis, Ch; Rasmussen, T R; Laopodis, V; Behrakis, P

    2002-04-01

    The influence of laparoscopic cholecystectomy (LC) on the mechanical properties of the respiratory system (RS) was examined using multiple regression analysis (MRA). Measurements of airway pressure (PaO) and flow (V') were obtained from 32 patients at four distinct stages of the LC procedure: 1) Immediately before the application of pneumoperitoneum (PP) at supine position, 2) 5 min after the induction of PP at Trendelenburg position, 3) 5 min after the patients position at reverse Trendelenburg, and 4) 5 min after the end ofthe surgical procedure with the patient again in supine position. Evaluated parameters were the RS elastance (Ers), resistance (Rrs), impedance (Zrs), the angle theta indicating the balance between the elastic and resistive components of the impedance, as well as the end-expiratory elastic recoil pressure (EEP). Ers and Zrs increased considerably during PP and remained elevated immediately after abolishing PP Rrs, on the contrary, returned to pre-operative levels right after the operation. Change of body position from Trendelenburg (T) to reverseTrendelenburg (rT) mainly induced a significant change in theta, thus indicating an increased dominance of the elastic component of Zrs on changing fromT to rT. There was no evidence of increased End-Expiratory Pressure during PP

  8. ACUTE RESPIRATORY DISEASE AS THE DEBUT OF SYSTEMIC LUPUS ERYTHEMATOSUS

    A. Yu. Ischenko

    2015-01-01

    Full Text Available Systemic lupus erythematosus — a chronic autoimmune disease that is often associated with infectious processes. The paper presents two clinical cases of systemic lupus erythematosus , debuted with acute respiratory infection.

  9. Influence of indoor formaldehyde pollution on respiratory system ...

    Some adults surveyed complained of common respiratory system disorders, including coughing (11.8%), nasal irritation (39.2%), Heterosmia (14.51%), and throat irritation (25.27%); 12% of children suffered from asthma. The analysis identified formaldehyde pollution and ventilation frequency as risk factors for respiratory ...

  10. Impact of cement dust pollution on respiratory systems of Lafarge ...

    In this investigation, the impact of cement dust pollution on respiratory systems of Lafarge cement workers was evaluated. A total of 120 respondents; 60 from the factory workers and 60 (controls) from Ifo, a nearby village 22 km NE of the factory were interviewed in 2014 using a modified respiratory symptom score ...

  11. Protective Alternatives of SMR against Extreme Threat Scenario – A Preliminary Risk Analysis

    Shohet, I.M.; Ornai, D.; Gal, E.; Ronen, Y.; Vidra, M.

    2014-01-01

    The article presents a preliminary risk analysis of the main features in NPP (Nuclear Power Plant) that includes SMR - Small and Modular Reactors, given an extreme threat scenario. A review of the structure and systems of the SMR is followed by systematic definitions and analysis of the threat scenario to which a preliminary risk analysis was carried out. The article outlines the basic events caused by the referred threat scenario, which had led to possible failure mechanisms according to FTA (Fault-Tree-Analysis),critical protective circuits, and todetecting critical topics for the protection and safety of the reactor

  12. An Analysis of Modern Japanese Think Tank Prototype——SMR Investigation Organization and Its Operation Mechanism

    Huang Wenyue

    2017-12-01

    Full Text Available [Purpose/significance] Through an analysis of SMR investigatory apparatus business and its operation mechanism, this paper discusses the development model of the investigation organ, the South Manchuria Railway think tank, and reveals the militarism influence on the early Japanese think tank development. [Method/process] This paper combed the SMR’s important survey agencies development pattern by the case study and literature survey and also discussed the key mechanism of operation system and organization characteristics. The evaluation of reports directed by the SMR provided references. [Result/conclusion] The SMR, as a colonial and aggressive policy tool, its surveys were done for the government and military authorities. With independent sources of information, the use of network intelligence structure and the combination of resident literature collection with field investigation, the collection of professional analysis personnel, the SMR investigation organization completes the decision-making through the scientific method and has reference value.

  13. The NtrY-NtrX two-component system is involved in controlling nitrate assimilation in Herbaspirillum seropedicae strain SmR1.

    Bonato, Paloma; Alves, Lysangela R; Osaki, Juliana H; Rigo, Liu U; Pedrosa, Fabio O; Souza, Emanuel M; Zhang, Nan; Schumacher, Jörg; Buck, Martin; Wassem, Roseli; Chubatsu, Leda S

    2016-11-01

    Herbaspirillum seropedicae is a diazotrophic β-Proteobacterium found endophytically associated with gramineae (Poaceae or graminaceous plants) such as rice, sorghum and sugar cane. In this work we show that nitrate-dependent growth in this organism is regulated by the master nitrogen regulatory two-component system NtrB-NtrC, and by NtrY-NtrX, which functions to specifically regulate nitrate metabolism. NtrY is a histidine kinase sensor protein predicted to be associated with the membrane and NtrX is the response regulator partner. The ntrYntrX genes are widely distributed in Proteobacteria. In α-Proteobacteria they are frequently located downstream from ntrBC, whereas in β-Proteobacteria these genes are located downstream from genes encoding an RNA methyltransferase and a proline-rich protein with unknown function. The NtrX protein of α-Proteobacteria has an AAA+ domain, absent in those from β-Proteobacteria. An ntrY mutant of H. seropedicae showed the wild-type nitrogen fixation phenotype, but the nitrate-dependent growth was abolished. Gene fusion assays indicated that NtrY is involved in the expression of genes coding for the assimilatory nitrate reductase as well as the nitrate-responsive two-component system NarX-NarL (narK and narX promoters, respectively). The purified NtrX protein was capable of binding the narK and narX promoters, and the binding site at the narX promoter for the NtrX protein was determined by DNA footprinting. In silico analyses revealed similar sequences in other promoter regions of H. seropedicae that are related to nitrate assimilation, supporting the role of the NtrY-NtrX system in regulating nitrate metabolism in H. seropedicae. © 2016 Federation of European Biochemical Societies.

  14. Study on the safety and on international developments of small modular reactors (SMR). Final report; Studie zur Sicherheit und zu internationalen Entwicklungen von Small Modular Reactors (SMR). Abschlussbericht

    Buchholz, Sebastian; Kruessenberg, Anne; Schaffrath, Andreas; Zipper, Reinhard

    2015-05-15

    This report documents the work and results of the project RS1521 Study of Safety and International Development of Small Modular Reactors (SMR). The aims of this study can be summarized as - setting-up of a sound overview on SMR, - identification of essential issues of reactor safety research and future R and D projects, - identification of needs for adaption of system codes of GRS used in reactor safety research. The sound overview consists of the descriptions of in total 69 SMR (Small and Medium Sized Rector) concepts (32 light water reactors (LWR), 22 liquid metal cooled reactors (LMR), 2 heavy water reactors, 9 gas cooled reactors (GCR) and 4 molten salt reactors (MSR)). It provides information about the core, the cooling circuits and the safety systems. The quality of the given specifications depends on their availability and public accessibility. Using the safety requirements for nuclear power plants and the fundamental safety functions, the safety relevant issues of the described SMR concepts were identified. The systems and measures used in the safety requirements were summarized in table form. Finally it was evaluated whether these systems and measures can be already simulated with the nuclear simulation chain of GRS and where further code development and validation is necessary. The results of this study can be summarized as follows: Many of the current SMR concepts are based on integral design. Here the main components like steam generators, intermediate heat exchangers or - in case of forced convection core cooling - main cooling pumps are located within the reactor pressure vessel. Most of the SMR fulfil highest safety standards and their safety concepts are mainly based on passive safety systems. The safety of theses reactors is achieved indefinitely without energy supply or additional measures of the operators. Since SMR's aim is not only to produce electricity but also couple them with chemical or physical process plants, the safety aspects of

  15. Computational Fluid and Particle Dynamics in the Human Respiratory System

    Tu, Jiyuan; Ahmadi, Goodarz

    2013-01-01

    Traditional research methodologies in the human respiratory system have always been challenging due to their invasive nature. Recent advances in medical imaging and computational fluid dynamics (CFD) have accelerated this research. This book compiles and details recent advances in the modelling of the respiratory system for researchers, engineers, scientists, and health practitioners. It breaks down the complexities of this field and provides both students and scientists with an introduction and starting point to the physiology of the respiratory system, fluid dynamics and advanced CFD modeling tools. In addition to a brief introduction to the physics of the respiratory system and an overview of computational methods, the book contains best-practice guidelines for establishing high-quality computational models and simulations. Inspiration for new simulations can be gained through innovative case studies as well as hands-on practice using pre-made computational code. Last but not least, students and researcher...

  16. [Development of expert diagnostic system for common respiratory diseases].

    Xu, Wei-hua; Chen, You-ling; Yan, Zheng

    2014-03-01

    To develop an internet-based expert diagnostic system for common respiratory diseases. SaaS system was used to build architecture; pattern of forward reasoning was applied for inference engine design; ASP.NET with C# from the tool pack of Microsoft Visual Studio 2005 was used for website-interview medical expert system.The database of the system was constructed with Microsoft SQL Server 2005. The developed expert system contained large data memory and high efficient function of data interview and data analysis for diagnosis of various diseases.The users were able to perform this system to obtain diagnosis for common respiratory diseases via internet. The developed expert system may be used for internet-based diagnosis of various respiratory diseases,particularly in telemedicine setting.

  17. Role of fluorographic examinations in diagnosis of respiratory system diseases

    Vil'derman, A.M.; Tsurkan, E.P.; Moskovchuk, A.F.

    1984-01-01

    Materials are considered on the role of fluorography in diagnosis of posttuberculous changes and chromic respiratory system diseases during total epidemiologic examination of 7791 adults from urban and rural population. A scheme is developed that characterize diagnosed pathology of respiratory organs with references to medical establishments rendering medical supervision and forms of supervision. It is shown that fluorograhic examination of the population provide an early diagnosis of both tuberculosis, neoplastic diseases and nonspecific pulmonary diseases that have no visible clinical symptomatology

  18. Experimental validation of TASS/SMR-S critical flow model for the integral reactor SMART

    Seo, Si Won; Ra, In Sik; Kim, Kun Yeup [ACT Co., Daejeon (Korea, Republic of); Chung, Young Jong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    An advanced integral PWR, SMART (System- Integrated Modular Advanced ReacTor) is being developed in KAERI. It has a compact size and a relatively small power rating (330MWt) compared to a conventional reactor. Because new concepts are applied to SMART, an experimental and analytical validation is necessary for the safety evaluation of SMART. The analytical safety validation is being accomplished by a safety analysis code for an integral reactor, TASS/SMR-S developed by KAERI. TASS/SMR-S uses a lumped parameter one dimensional node and path modeling for the thermal hydraulic calculation and it uses point kinetics for the reactor power calculation. It has models for a general usage such as a core heat transfer model, a wall heat structure model, a critical flow model, component models, and it also has many SMART specific models such as an once through helical coiled steam generator model, and a condensate heat transfer model. To ensure that the TASS/SMR-S code has the calculation capability for the safety evaluation of SMART, the code should be validated for the specific models with the separate effect test experimental results. In this study, TASS/SMR-S critical flow model is evaluated as compared with SMD (Super Moby Dick) experiment

  19. Activity of respiratory system during laser irradiation of brain structures

    Merkulova, N. A.; Sergeyeva, L. I.

    1984-06-01

    The performance of one of the principal links of the respiratory system, the respiratory center, was studied as a function of the exposure of the medulla oblongata and the sensomotor zone of the cerebral hemisphere cortex to low level laser irradiation in the red wavelength of the spectrum. Experiments were done on white rats under barbital anesthesia. Under such conditions a substantial effect was observed on the activity of the respiratory center. Laser light may display activating or inhibitory influences, in some cases the bilateral symmetry of the activity of the respiratory center is affected indicating deep changes in the integrative mechanism of the functioning of the right and left sides of the hemispheres. The laser beam effect depends on many factors: specific light properties, duration of the exposure, repetition of exposures, initial functional state of the CNS, etc.

  20. Visuo-motor coordination ability predicts performance with brain-computer interfaces controlled by modulation of sensorimotor rhythms (SMR

    Eva Maria Hammer

    2014-08-01

    Full Text Available Modulation of sensorimotor rhythms (SMR was suggested as a control signal for brain-computer interfaces (BCI. Yet, there is a population of users estimated between 10 to 50% not able to achieve reliable control and only about 20% of users achieve high (80-100% performance. Predicting performance prior to BCI use would facilitate selection of the most feasible system for an individual, thus constitute a practical benefit for the user, and increase our knowledge about the correlates of BCI control. In a recent study, we predicted SMR-BCI performance from psychological variables that were assessed prior to the BCI sessions and BCI control was supported with machine-learning techniques. We described two significant psychological predictors, namely the visuo-motor coordination ability and the ability to concentrate on the task. The purpose of the current study was to replicate these results thereby validating these predictors within a neurofeedback based SMR-BCI that involved no machine learning. Thirty-three healthy BCI novices participated in a calibration session and three further neurofeedback training sessions. Two variables were related with mean SMR-BCI performance: (1 A measure for the accuracy of fine motor skills, i.e. a trade for a person’s visuo-motor control ability and (2 subject’s attentional impulsivity. In a linear regression they accounted for almost 20% in variance of SMR-BCI performance, but predictor (1 failed significance. Nevertheless, on the basis of our prior regression model for sensorimotor control ability we could predict current SMR-BCI performance with an average prediction error of M = 12.07%. In more than 50% of the participants, the prediction error was smaller than 10%. Hence, psychological variables played a moderate role in predicting SMR-BCI performance in a neurofeedback approach that involved no machine learning. Future studies are needed to further consolidate (or reject the present predictors.

  1. [Aging of the respiratory system: anatomical changes and physiological consequences].

    Ketata, W; Rekik, W K; Ayadi, H; Kammoun, S

    2012-10-01

    The respiratory system undergoes progressive involution with age, resulting in anatomical and functional changes that are exerted on all levels. The rib cage stiffens and respiratory muscles weaken. Distal bronchioles have reduced diameter and tend to be collapsed. Mobilized lung volumes decrease with age while residual volume increases. Gas exchanges are modified with a linear decrease of PaO(2) up to the age of 70 years and a decreased diffusing capacity of carbon monoxide. Ventilatory responses to hypercapnia, hypoxia and exercise decrease in the elderly. Knowledge of changes in the respiratory system related to advancing age is a medical issue of great importance in order to distinguish the effects of aging from those of diseases. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. Mobilisation of toxic elements in the human respiratory system

    Pinheiro, T.; Alves, L.C.; Palhano, M.J.; Bugalho de Almeida, A.

    2001-01-01

    The fate of respired particles in the respiratory system is inferred through the chemical characterisation of individual particles at the tracheal and bronchial mucosas, and the accumulation of toxic elements in lung alveoli and lymph nodes. The particles and tissue elemental distributions were identified and characterised using micro-PIXE elemental mapping of thin frozen sections using the ITN Nuclear Microprobe facility. Significant particle deposits are found at the distal respiratory tract. Al, Si, Ti, V, Cr, Fe, Ni, Cu and Zn are elements detected at these accumulation areas. The elemental distributions in the different cellular environments of lymph nodes vary. The major compartments for Al, Si, Ti, Fe and Cr are the phagocytic cells and capsule of lymph nodes, while V and Ni are in the cortex and paracortex medullar areas which retain more than 70% of these two elements, suggesting high solubility of the latter in the cellular milieu. The elemental mobilisation from particles or deposits to surrounding tissues at the respiratory ducts evidences patterns of diffusion and removal that are different than those for elements in the respiratory tract. Mobilisation of elements such as V, Cr and Ni is more relevant at alveoli areas where gaseous exchange takes place. The apparent high solubility of V and Ni in the respiratory tract tissue points towards a deviation of the lymphatic system filtering efficiency for these elements when compared to others

  3. Evaluation of exercise-respiratory system modifications and integration schemes for physiological systems

    Gallagher, R. R.

    1974-01-01

    Exercise subroutine modifications are implemented in an exercise-respiratory system model yielding improvement of system response to exercise forcings. A more physiologically desirable respiratory ventilation rate in addition to an improved regulation of arterial gas tensions and cerebral blood flow is observed. A respiratory frequency expression is proposed which would be appropriate as an interfacing element of the respiratory-pulsatile cardiovascular system. Presentation of a circulatory-respiratory system integration scheme along with its computer program listing is given. The integrated system responds to exercise stimulation for both nonstressed and stressed physiological states. Other integration possibilities are discussed with respect to the respiratory, pulsatile cardiovascular, thermoregulatory, and the long-term circulatory systems.

  4. Gap conductance model validation in the TASS/SMR-S code

    Ahn, Sang-Jun; Yang, Soo-Hyung; Chung, Young-Jong; Bae, Kyoo-Hwan; Lee, Won-Jae

    2011-01-01

    An advanced integral pressurized water reactor, SMART (System-Integrated Modular Advanced ReacTor) has been developed by KAERI (Korea Atomic Energy Research and Institute). The purposes of the SMART are sea water desalination and an electricity generation. For the safety evaluation and performance analysis of the SMART, TASS/SMR-S (Transient And Setpoint Simulation/System-integrated Modular Reactor) code, has been developed. In this paper, the gap conductance model for the calculation of gap conductance has been validated by using another system code, MARS code, and experimental results. In the validation, the behaviors of fuel temperature and gap width are selected as the major parameters. According to the evaluation results, the TASS/SMR-S code predicts well the behaviors of fuel temperatures and gap width variation, compared to the MARS calculation results and experimental data. (author)

  5. Effect of ultraviolet exposure on mitochondrial respiratory system

    Noda, K [Kurume Univ., Fukuoka (Japan). School of Medicine

    1975-09-01

    To find the photodynamic effect of ultraviolet light on the mitochondrial respiratory chain, mitochondria were obtained from rat livers, and the suspension was exposed to an extensive ultraviolet light. The oxygen consumption was measured polarographically with a Clark oxygen electrode. The effect of ultraviolet exposure on the five states of respiratory control (Chance and Williams), the P/O ratio, and the respiratory control index in mitochondria was discussed. The ultraviolet light with a dose of 9.6 x 10/sup 6/ erg/cm/sup 2/ caused the oxidative phosphorylation in mitochondria to uncouple. The 2nd phosphorylation site of the respiratory chain was susceptible to ultraviolet exposure. The stimulation of latent ATPase activity in mitochondria following exposure was observed by increasing exposure of ultraviolet light. However, DNP-stimulated ATPase was found to be stable in activity. The uncoupling of the respiratory chain by ultraviolet exposure was not detected if the mitochondrial suspension was preincubated with bovine serum albumin before exposure. The changes in light absorption of the mitochondrial suspension were followed at 520 nm after exposure. A close correlation was found between the ultraviolet exposure and swelling in mitochondria. But, the reversing contraction was observed by adding ATP to the swelled mitochondria. The peroxide compound was formed in mitochondria irradiated with ultraviolet light. The amount of compounds formed was dependent on the radiant energy of ultraviolet light. The possible mechanisms involved in the photodynamic effect of ultraviolet light to the mitochondrial respiration system were discussed.

  6. 3-D Model of the Human Respiratory System

    The U.S. EPA’s Office of Research and Development (ORD) has developed a 3-D computational fluid dynamics (CFD) model of the human respiratory system that allows for the simulation of particulate based contaminant deposition and clearance, while being adaptable for age, ethnicity,...

  7. Computational 3-D Model of the Human Respiratory System

    We are developing a comprehensive, morphologically-realistic computational model of the human respiratory system that can be used to study the inhalation, deposition, and clearance of contaminants, while being adaptable for age, race, gender, and health/disease status. The model ...

  8. Cancer epidemiology in respiratory system among uranium miners

    Moraes, A.

    1976-11-01

    A summary of some published papers about cancer in respiratory system among uranium miners is presented. A comparative table relating cancer cases among uranium miners is shown. A table relating cases among miners in Checoslovaquia and cumulative exposure levels due to radon daughter products is also given [pt

  9. Research gaps and technology needs in development of PHM for passive AdvSMR components

    Meyer, Ryan M.; Ramuhalli, Pradeep; Hirt, Evelyn H.; Mitchell, Mark R.; Wootan, David W.; Berglin, Eric J.; Henagar, Chuck H. Jr. [Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99352 (United States); Coble, Jamie B. [University of Tennessee, Knoxville, Department of Nuclear Engineering, 315 Pasqua Engineering Building, Knoxville, TN 37996 (United States); Bond, Leonard J. [Iowa State University, Center for Nondestructive Evaluation, 1915 Scholl Rd., Ames, IA 50011 (United States)

    2014-02-18

    Advanced small modular reactors (AdvSMRs), which are based on modularization of advanced reactor concepts, may provide a longer-term alternative to traditional light-water reactors and near-term small modular reactors (SMRs), which are based on integral pressurized water reactor (iPWR) concepts. SMRs are challenged economically because of losses in economy of scale; thus, there is increased motivation to reduce the controllable operations and maintenance costs through automation technologies including prognostics health management (PHM) systems. In this regard, PHM systems have the potential to play a vital role in supporting the deployment of AdvSMRs and face several unique challenges with respect to implementation for passive AdvSMR components. This paper presents a summary of a research gaps and technical needs assessment performed for implementation of PHM for passive AdvSMR components.

  10. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Hugo, Jacques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Forester, John [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gertman, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Medema, Heather [Idaho National Lab. (INL), Idaho Falls, ID (United States); Persensky, Julius [Idaho National Lab. (INL), Idaho Falls, ID (United States); Whaley, April [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-08-01

    This report presents preliminary research results from the investigation into the development of new models and guidance for Concepts of Operations in advanced small modular reactor (AdvSMR) designs. AdvSMRs are nuclear power plants (NPPs), but unlike conventional large NPPs that are constructed on site, AdvSMRs systems and components will be fabricated in a factory and then assembled on site. AdvSMRs will also use advanced digital instrumentation and control systems, and make greater use of automation. Some AdvSMR designs also propose to be operated in a multi-unit configuration with a single central control room as a way to be more cost-competitive with existing NPPs. These differences from conventional NPPs not only pose technical and operational challenges, but they will undoubtedly also have regulatory compliance implications, especially with respect to staffing requirements and safety standards.

  11. Respiratory protective device design using control system techniques

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  12. Investigating parameters participating in the infant respiratory control system attractor.

    Terrill, Philip I; Wilson, Stephen J; Suresh, Sadasivam; Cooper, David M; Dakin, Carolyn

    2008-01-01

    Theoretically, any participating parameter in a non-linear system represents the dynamics of the whole system. Taken's time delay embedding theory provides the fundamental basis for allowing non-linear analysis to be performed on physiological, time-series data. In practice, only one measurable parameter is required to be measured to convey an accurate representation of the system dynamics. In this paper, the infant respiratory control system is represented using three variables-a digitally sampled respiratory inductive plethysmography waveform, and the derived parameters tidal volume and inter-breath interval time series data. For 14 healthy infants, these data streams were analysed using recurrence plot analysis across one night of sleep. The measured attractor size of these variables followed the same qualitative trends across the nights study. Results suggest that the attractor size measures of the derived IBI and tidal volume are representative surrogates for the raw respiratory waveform. The extent to which the relative attractor sizes of IBI and tidal volume remain constant through changing sleep state could potentially be used to quantify pathology, or maturation of breathing control.

  13. 38 CFR 4.97 - Schedule of ratings-respiratory system.

    2010-07-01

    ...-respiratory system. 4.97 Section 4.97 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Respiratory System § 4.97 Schedule of ratings—respiratory system. Rating DISEASES OF THE NOSE AND THROAT 6502Septum, nasal, deviation of: Traumatic only...

  14. TASS/SMR Code Topical Report for SMART Plant, Vol II: User's Guide and Input Requirement

    Kim, See Darl; Kim, Soo Hyoung; Kim, Hyung Rae

    2008-10-01

    The TASS/SMR code has been developed with domestic technologies for the safety analysis of the SMART plant which is an integral type pressurized water reactor. It can be applied to the analysis of design basis accidents including non-LOCA (loss of coolant accident) and LOCA of the SMART plant. The TASS/SMR code can be applied to any plant regardless of the structural characteristics of a reactor since the code solves the same governing equations for both the primary and secondary system. The code has been developed to meet the requirements of the safety analysis code. This report describes the overall structure of the TASS/SMR, input processing, and the processes of a steady state and transient calculations. In addition, basic differential equations, finite difference equations, state relationships, and constitutive models are described in the report. First, the conservation equations, a discretization process for numerical analysis, search method for state relationship are described. Then, a core power model, heat transfer models, physical models for various components, and control and trip models are explained

  15. Development of MIDAS/SMR Input Deck for SMART

    Cho, S. W.; Oh, H. K.; Lee, J. M.; Lee, J. H.; Yoo, K. J.; Kwun, S. K.; Hur, H.

    2010-01-01

    The objective of this study is to develop MIDAS/SMR code basic input deck for the severe accidents by simulating the steady state for the SMART plant. SMART plant is an integrated reactor developed by KAERI. For the assessment of reactor safety and severe accident management strategy, it is necessary to simulate severe accidents using the MIDAS/SMR code which is being developed by KAERI. The input deck of the MIDAS/SMR code for the SMART plant is prepared to simulate severe accident sequences for the users who are not familiar with the code. A steady state is obtained and the results are compared with design values. The input deck will be improved through the simulation of the DBAs and severe accidents. The base input deck of the MIDAS/SMR code can be used to simulate severe accident scenarios after improvement. Source terms and hydrogen generation can be analyzed through the simulation of the severe accident. The information gained from analyses of severe accidents is expected to be helpful to develop the severe accident management strategy

  16. Numerical simulation of volume-controlled mechanical ventilated respiratory system with 2 different lungs.

    Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas

    2017-09-01

    Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Lung volume recruitment acutely increases respiratory system compliance in individuals with severe respiratory muscle weakness

    Yannick Molgat-Seon

    2017-03-01

    Full Text Available The aim of the present study was to determine whether lung volume recruitment (LVR acutely increases respiratory system compliance (Crs in individuals with severe respiratory muscle weakness (RMW. Individuals with RMW resulting from neuromuscular disease or quadriplegia (n=12 and healthy controls (n=12 underwent pulmonary function testing and the measurement of Crs at baseline, immediately after, 1 h after and 2 h after a single standardised session of LVR. The LVR session involved 10 consecutive supramaximal lung inflations with a manual resuscitation bag to the highest tolerable mouth pressure or a maximum of 50 cmH2O. Each LVR inflation was followed by brief breath-hold and a maximal expiration to residual volume. At baseline, individuals with RMW had lower Crs than controls (37±5 cmH2O versus 109±10 mL·cmH2O−1, p0.05. LVR had no significant effect on measures of pulmonary function at any time point in either group (all p>0.05. During inflations, mean arterial pressure decreased significantly relative to baseline by 10.4±2.8 mmHg and 17.3±3.0 mmHg in individuals with RMW and controls, respectively (both p<0.05. LVR acutely increases Crs in individuals with RMW. However, the high airway pressures during inflations cause reductions in mean arterial pressure that should be considered when applying this technique.

  18. Virtual respiratory system for interactive e-learning of spirometry

    W. Tomalak

    2008-04-01

    Full Text Available Progress in computer simulation technology offers new possibilities for modern medicine. On one hand – virtual organs can help to create animal or human models for research, on the other hand – e-learning or distant learning through Internet is now possible. The aim of our work was to create a system for interactive learning of spirometry (SILS, enabling students or physicians to observe spirometric measurements (flow-volume modified by setting level and kind of abnormalities within the respiratory system. SILS is based on a virtual respiratory system presented previously in several papers. Its main features are: separation of the lungs and chest; anatomical division of the lungs; division of airway resistance into transmural pressure dependent (Rp and lung volume dependent (Rv parts. The one mathematical formula that represents Rp describes both flow limitation (forced expiration and dependence of Raw on lungs volume (small airflows. The output of system are spirometric parameters (as FEV1, FVC, FEV1%FVC and a flow–volume loop constructed according to results of simulation of forced expiration for the chosen abnormality kind and level. As a result – this system may be used in teaching process in medical schools and postgraduate education. We offer access to a basic version of SILS for students and physicians at: www.spirometry.ibib.waw.pl and www.zpigichp.edu.pl. As we expect feedback from users, it is possible to modify user interface or model features to comply with users' requests.

  19. Cellular defense of the avian respiratory system: effects of Pasteurella multocida on respiratory burst activity of avian respiratory tract phagocytes.

    Ochs, D L; Toth, T E; Pyle, R H; Siegel, P B

    1988-12-01

    The respiratory tract of healthy chickens contain few free-residing phagocytic cells. Intratracheal inoculation with Pasteurella multocida stimulated a significant (P less than 0.05) migration of cells to the lungs and air sacs of White Rock chickens within 2 hours after inoculation. We found the maximal number of avian respiratory tract phagocytes (22.9 +/- 14.0 x 10(6] at 8 hours after inoculation. Flow cytometric analysis of these cells revealed 2 populations on the basis of cell-size and cellular granularity. One of these was similar in size and granularity to those of blood heterophils. Only this population was capable of generating oxidative metabolites in response to phorbol myristate acetate. The ability of the heterophils to produce hydrogen peroxide, measured as the oxidation of intracellularly loaded 2',7'-dichlorofluorescein, decreased with time after inoculation. These results suggest that the migration of heterophils, which are capable of high levels of oxidative metabolism, to the lungs and air sacs may be an important defense mechanism of poultry against bacterial infections of the respiratory tract.

  20. Human respiratory tract model for radiological protection: A revision of the ICRP Dosimetric Model for the Respiratory System

    Bair, W.J.

    1989-01-01

    In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users

  1. A Novel Parametric Model For The Human Respiratory System

    Clara Mihaela IONESCU

    2003-12-01

    Full Text Available The purpose of this work is to present some recent results in an ongoing research project between Ghent University and Chess Medical Technology Company Belgium. The overall aim of the project is to provide a fast method for identification of the human respiratory system in order to allow for an instantaneously diagnosis of the patient by the medical staff. A novel parametric model of the human respiratory system as well as the obtained experimental results is presented in this paper. A prototype apparatus developed by the company, based on the forced oscillation technique is used to record experimental data from 4 patients in this paper. Signal processing is based on spectral analysis and is followed by the parametric identification of a non-linear mechanistic model. The parametric model is equivalent to the structure of a simple electrical RLC-circuit, containing a non-linear capacitor. These parameters have a useful and easy-to-interpret physical meaning for the medical staff members.

  2. The Steady State Calculation for SMART with MIDAS/SMR

    Park, Jong Hwa; Kim, Dong Ha; Chung, Young Jong; Park, Sun Hee; Cho, Seong Won

    2010-01-01

    KAERI is developing a new concept of reactor that all the main components such as the steam generator, the coolant pumps and the pressurizer are located inside the reactor vessel. Before the severe accident sequences are estimated, it is prerequisite that MIDAS code predicts the steady state conditions properly. But MIDAS code does not include the heat transfer model for the helical tube. Therefore, the heat transfer models for the helical tube from TASS/SMR-S were implemented into MIDAS code. To estimate the validity of the implemented heat transfer correlations for the helical tube and the input data, the steady state was recalculated with MIDAS/SMR based on design level 2 and compared with the design values

  3. Small modular reactor (SMR) development plan in Korea

    Shin, Yong-Hoon, E-mail: chaotics@snu.ac.kr; Park, Sangrok; Kim, Byong Sup; Choi, Swongho; Hwang, Il Soon [Nuclear Transmutation Energy Research Center, Seoul National University, Bldg.31-1, 1 Gwanak-ro, Gwanak-gu, Seoul, Republic of Korea, 151-742 (Korea, Republic of)

    2015-04-29

    Since the first nuclear power was engaged in Korean electricity grid in 1978, intensive research and development has been focused on localization and standardization of large pressurized water reactors (PWRs) aiming at providing Korean peninsula and beyond with economical and safe power source. With increased priority placed on the safety since Chernobyl accident, Korean nuclear power R and D activity has been diversified into advanced PWR, small modular PWR and generation IV reactors. After the outbreak of Fukushima accident, inherently safe small modular reactor (SMR) receives growing interest in Korea and Europe. In this paper, we will describe recent status of evolving designs of SMR, their advantages and challenges. In particular, the conceptual design of lead-bismuth cooled SMR in Korea, URANUS with 40∼70 MWe is examined in detail. This paper will cover a framework of the program and a strategy for the successful deployment of small modular reactor how the goals would entail and the approach to collaboration with other entities.

  4. Respiratory monitoring system based on fiber optic macro bending

    Purnamaningsih, Retno Wigajatri; Widyakinanti, Astari; Dhia, Arika; Gumelar, Muhammad Raditya; Widianto, Arif; Randy, Muhammad; Soedibyo, Harry

    2018-02-01

    We proposed a respiratory monitoring system for living activities in human body based on fiber optic macro-bending for laboratory scale. The respiration sensor consists of a single-mode optical fiber and operating on a wavelength at around 1550 nm. The fiber optic was integrated into an elastic fabric placed on the chest and stomach of the monitored human subject. Deformations of the flexible textile involving deformations of the fiber optic bending curvature, which was proportional to the chest and stomach expansion. The deformation of the fiber was detected using photodetector and processed using microcontroller PIC18F14K50. The results showed that this system able to display various respiration pattern and rate for sleeping, and after walking and running activities in real time.

  5. Verification and compensation of respiratory motion using an ultrasound imaging system

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Chiu, Wei-Hung; Tien, Der-Chi; Wu, Ren-Hong; Hsu, Chung-Hsien

    2015-01-01

    Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm

  6. Mathematical modelling of a human external respiratory system

    1977-01-01

    A closed system of algebraic and common differential equations solved by computer is investigated. It includes equations which describe the activity pattern of the respiratory center, the phrenic nerve, the thrust produced by the diaphragm as a function of the lung volume and discharge frequency of the phrenic nerve, as well as certain relations of the lung stretch receptors and chemoreceptors on various lung and blood characteristics, equations for lung biomechanics, pulmonary blood flow, alveolar gas exchange and capillary blood composition equations to determine various air and blood flow and gas exchange parameters, and various gas mixing and arterial and venous blood composition equations, to determine other blood, air and gas mixing characteristics. Data are presented by means of graphs and tables, and some advantages of this model over others are demonstrated by test results.

  7. Shutting down sensorimotor interference unblocks the networks for stimulus processing: an SMR neurofeedback training study.

    Kober, Silvia Erika; Witte, Matthias; Stangl, Matthias; Väljamäe, Aleksander; Neuper, Christa; Wood, Guilherme

    2015-01-01

    In the present study, we investigated how the electrical activity in the sensorimotor cortex contributes to improved cognitive processing capabilities and how SMR (sensorimotor rhythm, 12-15Hz) neurofeedback training modulates it. Previous evidence indicates that higher levels of SMR activity reduce sensorimotor interference and thereby promote cognitive processing. Participants were randomly assigned to two groups, one experimental (N=10) group receiving SMR neurofeedback training, in which they learned to voluntarily increase SMR, and one control group (N=10) receiving sham feedback. Multiple cognitive functions and electrophysiological correlates of cognitive processing were assessed before and after 10 neurofeedback training sessions. The experimental group but not the control group showed linear increases in SMR power over training runs, which was associated with behavioural improvements in memory and attentional performance. Additionally, increasing SMR led to a more salient stimulus processing as indicated by increased N1 and P3 event-related potential amplitudes after the training as compared to the pre-test. Finally, functional brain connectivity between motor areas and visual processing areas was reduced after SMR training indicating reduced sensorimotor interference. These results indicate that SMR neurofeedback improves stimulus processing capabilities and consequently leads to improvements in cognitive performance. The present findings contribute to a better understanding of the mechanisms underlying SMR neurofeedback training and cognitive processing and implicate that SMR neurofeedback might be an effective cognitive training tool. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  8. The Respiratory System. Instructional Materials in Anatomy and Physiology for Pennsylvania Health Occupations Programs.

    National Evaluation Systems, Inc., Amherst, MA.

    This instructional modular unit with instructor's guide provides materials on aspects of one of the major systems of the human body--the respiratory system. Its purpose is to introduce the student to the structures and functions of the human respiratory system--and the interrelationships of the two--and to famlliarize the student with some of the…

  9. Evaluation of the MEMS based portable respiratory training system with a tactile sensor for respiratory-gated radiotherapy

    Moon, Sun Young; Yoon, Myonggeun; Chung, Mijoo; Chung, Weon Kuu; Kim, Dong Wook

    2017-10-01

    In respiratory-gated radiotherapy, it is important to maintain the regular respiratory cycles of patients. If patients undergo respiration training, their regular breathing pattern is affected. Therefore, we developed a respiratory training system based on a micro electromechanical system (MEMS) and evaluated the feasibility of the MEMS in radiotherapy. By comparing the measured signal before and after radiation exposure, we confirmed the effects of radiation. By evaluating the period of the electric signal emitted by a tactile sensor and its constancy, the performance of the tactile sensor was confirmed. Moreover, by comparing the delay between the motion of the MEMS and the electric signal from the tactile sensor, we confirmed the reaction time of the tactile sensor. The results showed that a baseline shift occurred for an accumulated dose of 400 Gy in the sensor, and both the amplitude and period changed. The period of the signal released by the tactile sensor was 5.39 and its standard deviation was 0.06. Considering the errors from the motion phantom, a standard deviation of 0.06 was desirable. The delay time was within 0.5 s and not distinguishable by a patient. We confirmed the performance of the MEMS and concluded that MEMS could be applied to patients for respiratory-gated radiotherapy.

  10. Information system for diagnosis of respiratory system diseases

    Abramov, G. V.; Korobova, L. A.; Ivashin, A. L.; Matytsina, I. A.

    2018-05-01

    An information system is for the diagnosis of patients with lung diseases. The main problem solved by this system is the definition of the parameters of cough fragments in the monitoring recordings using a voice recorder. The authors give the recognition criteria of recorded cough moments, audio records analysis. The results of the research are systematized. The cough recognition system can be used by the medical specialists to diagnose the condition of the patients and to monitor the process of their treatment.

  11. Breath pacing system and method for pacing the respiratory activity of a subject

    2016-01-01

    To provide a breath pacing system and a corresponding method for pacing the respiratory activity of a subject that provide the possibility to adapt the output signal to the respiration characteristics of the subject automatically and effectively a breath pacing system (10) for pacing the respiratory

  12. An alternative respiratory sounds classification system utilizing artificial neural networks

    Rami J Oweis

    2015-04-01

    Full Text Available Background: Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. Methods: This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs and adaptive neuro-fuzzy inference systems (ANFIS toolboxes. The methods have been applied to 10 different respiratory sounds for classification. Results: The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. Conclusions: The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.

  13. B lymphocyte lineage cells and the respiratory system

    Kato, Atsushi; Hulse, Kathryn E.; Tan, Bruce K.; Schleimer, Robert P.

    2013-01-01

    Adaptive humoral immune responses in the airways are mediated by B cells and plasma cells that express highly evolved and specific receptors and produce immunoglobulins of most isotypes. In some cases, such as autoimmune diseases or inflammatory diseases caused by excessive exposure to foreign antigens, these same immune cells can cause disease by virtue of overly vigorous responses. This review discusses the generation, differentiation, signaling, activation and recruitment pathways of B cells and plasma cells, with special emphasis on unique characteristics of subsets of these cells functioning within the respiratory system. The primary sensitization events that generate B cells responsible for effector responses throughout the airways usually occur in the upper airways, in tonsils and adenoid structures that make up Waldeyer’s Ring. Upon secondary exposure to antigen in the airways, antigen-processing dendritic cells migrate into secondary lymphoid organs such as lymph nodes that drain the upper and lower airways and further B cell expansion takes place at those sites. Antigen exposure in the upper or lower airways can also drive expansion of B lineage cells in the airway mucosal tissue and lead to the formation of inducible lymphoid follicles or aggregates that can mediate local immunity or disease. PMID:23540615

  14. TASS/SMR Code Topical Report for SMART Plant, Vol II: User's Guide and Input Requirement

    Kim, See Darl; Kim, Soo Hyoung; Kim, Hyung Rae (and others)

    2008-10-15

    The TASS/SMR code has been developed with domestic technologies for the safety analysis of the SMART plant which is an integral type pressurized water reactor. It can be applied to the analysis of design basis accidents including non-LOCA (loss of coolant accident) and LOCA of the SMART plant. The TASS/SMR code can be applied to any plant regardless of the structural characteristics of a reactor since the code solves the same governing equations for both the primary and secondary system. The code has been developed to meet the requirements of the safety analysis code. This report describes the overall structure of the TASS/SMR, input processing, and the processes of a steady state and transient calculations. In addition, basic differential equations, finite difference equations, state relationships, and constitutive models are described in the report. First, the conservation equations, a discretization process for numerical analysis, search method for state relationship are described. Then, a core power model, heat transfer models, physical models for various components, and control and trip models are explained.

  15. The French approach through the SMR consortium (CEA, EDF, AREVA, DCNS)

    Chenais, J.; Diet, A.; Grondin, Y.; Perrier, S.

    2014-01-01

    The SMR (Small Modular Reactor) is a new range of nuclear reactors characterized by a low output power (less than 300 MWe) and a standardized modular factory-based construction. Moderate capital costs make this type of reactor very attractive for medium-size power utilities or small countries. A consortium made around the CEA and its industrial partners (EDF, AREVA and DCNS) has performed economic and technical feasibility studies. It appears that the competitiveness of SMR require power production costs around 100 euros/MWh and that SMR will be based on PWR technology with a power output of 150 MWe per unit. 2 types of SMR are proposed: a terrestrial unit and an immersed unit. The concept of the immersed SMR, called Flexblue, is based on an unlimited access to a cold sink (the ocean) and a complete modularity. In both types the standard of safety appears to be high. (A.C.)

  16. Pre-Analysis for Safety-Related Verification Test Using TASS/SMR Code

    Ra, I. S.; Kim, H. J.; Jeon, G. H. [ACTS Ltd., Daejeon (Korea, Republic of)

    2010-01-15

    General trends of TASS/SMR simulation were similar to those in both ORNF test and BENNETT test conducted to verify core heat transfer model in TASS/SMR. In high mass flux, however, a CHF location in the analytical result of TASS/SMR was greatly deviated from BENNETT test result. TASS/SMR gave better results in heterogeneous option that in homogeneous option in both KIT test, which was a steady state test with an inlet flow, and GE-LEVEL Swell test, which a transient test without an inlet flow. TASS/SMR simulation for SMD Long and Short test gave a good agreement with the test results in showing a reasonable predictability of critical flow model. But, in the case of Marviken test, the analytical result was not similar to the test result after the timing of vapor generation

  17. Respiratory and Systemic Effects of LASSBio596 Plus Surfactant in Experimental Acute Respiratory Distress Syndrome

    Johnatas Dutra Silva

    2016-02-01

    Full Text Available Background/Aims: Exogenous surfactant has been proposed as adjunctive therapy for acute respiratory distress syndrome (ARDS, but it is inactivated by different factors present in the alveolar space. We hypothesized that co-administration of LASSBio596, a molecule with significant anti-inflammatory properties, and exogenous surfactant could reduce lung inflammation, thus enabling the surfactant to reduce edema and improve lung function, in experimental ARDS. Methods: ARDS was induced by cecal ligation and puncture surgery in BALB/c mice. A sham-operated group was used as control (CTRL. After surgery (6 hours, CTRL and ARDS animals were assigned to receive: (1 sterile saline solution; (2 LASSBio596; (3 exogenous surfactant or (4 LASSBio596 plus exogenous surfactant (n = 22/group. Results: Regardless of exogenous surfactant administration, LASSBio596 improved survival rate and reduced collagen fiber content, total number of cells and neutrophils in PLF and blood, cell apoptosis, protein content in BALF, and urea and creatinine levels. LASSBio596 plus surfactant yielded all of the aforementioned beneficial effects, as well as increased BALF lipid content and reduced surface tension. Conclusion: LASSBio596 exhibited major anti-inflammatory and anti-fibrogenic effects in experimental sepsis-induced ARDS. Its association with surfactant may provide further advantages, potentially by reducing surface tension.

  18. Thermal-hydraulic analysis of SMART steam generator tube rupture using TASS/SMR-S code

    Kim, Hee-Kyung; Kim, Soo Hyoung; Chung, Young-Jong; Kim, Hyeon-Soo

    2013-01-01

    Highlights: ► The analysis was performed from the viewpoint of primary coolant leakage. ► The thermal hydraulic responses and the maximum leakage have been identified. ► There is no direct release into the atmosphere caused by an SGTR accident. ► SMART safety system works well against an SGTR accident. - Abstract: A steam generator tube rupture (SGTR) accident analysis for SMART was performed using the TASS/SMR-S code. SMART with a rated thermal power of 330 MWt has been developed at the Korea Atomic Energy Research Institute. The TASS/SMR-S code can analyze the thermal hydraulic phenomena of SMART in a full range of reactor operating conditions. An SGTR is one of the most important accidents from a thermal hydraulic and radiological viewpoint. A conservative analysis against a SMART SGTR was performed. The major concern of this analysis is to find the thermal hydraulic responses and maximum leakage amount from a primary to a secondary side caused by an SGTR accident. A sensitivity study searching for the conservative thermal hydraulic conditions, break locations, reactivity and other conditions was performed. The dominant parameters related with the integral leak are the high RCS pressure, low core inlet coolant temperature and low break location of the SG cassette. The largest integral leak comes to 28 tons in the most conservative case during 1 h. But there is no direct release into the atmosphere because the secondary system pressure is maintained with a sufficient margin for the design pressure. All leaks go to the condenser. The analysis results show that the primary and secondary system pressures are maintained below the design pressure and the SMART safety system is working well against an SGTR accident

  19. Effects on respiratory system due to exposure to wheat flour

    Adel Mohammed Said

    2017-07-01

    Conclusions: Exposure to wheat flour increases the risk of developing respiratory symptoms; it also causes reduction in the pulmonary function parameters, as regards spirometry and DLCOSB. Exposure to wheat flour causes interstitial lung disease as detected by HRCT chest. Smoking augments the wheat flour induced lung disease.

  20. Nitric oxide in health and disease of the respiratory system

    Ricciardolo, Fabio L. M.; Sterk, Peter J.; Gaston, Benjamin; Folkerts, Gert

    2004-01-01

    During the past decade a plethora of studies have unravelled the multiple roles of nitric oxide (NO) in airway physiology and pathophysiology. In the respiratory tract, NO is produced by a wide variety of cell types and is generated via oxidation of l-arginine that is catalyzed by the enzyme NO

  1. Timely diagnosis of dairy calf respiratory disease using a standardized scoring system.

    McGuirk, Sheila M; Peek, Simon F

    2014-12-01

    Respiratory disease of young dairy calves is a significant cause of morbidity, mortality, economic loss, and animal welfare concern but there is no gold standard diagnostic test for antemortem diagnosis. Clinical signs typically used to make a diagnosis of respiratory disease of calves are fever, cough, ocular or nasal discharge, abnormal breathing, and auscultation of abnormal lung sounds. Unfortunately, routine screening of calves for respiratory disease on the farm is rarely performed and until more comprehensive, practical and affordable respiratory disease-screening tools such as accelerometers, pedometers, appetite monitors, feed consumption detection systems, remote temperature recording devices, radiant heat detectors, electronic stethoscopes, and thoracic ultrasound are validated, timely diagnosis of respiratory disease can be facilitated using a standardized scoring system. We have developed a scoring system that attributes severity scores to each of four clinical parameters; rectal temperature, cough, nasal discharge, ocular discharge or ear position. A total respiratory score of five points or higher (provided that at least two abnormal parameters are observed) can be used to distinguish affected from unaffected calves. This can be applied as a screening tool twice-weekly to identify pre-weaned calves with respiratory disease thereby facilitating early detection. Coupled with effective treatment protocols, this scoring system will reduce post-weaning pneumonia, chronic pneumonia, and otitis media.

  2. A new laboratory-based surveillance system (Respiratory DataMart System) for influenza and other respiratory viruses in England: results and experience from 2009 to 2012.

    Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R

    2014-01-23

    During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.

  3. Contraindications to Athletic Participation. Cardiac, Respiratory, and Central Nervous System Conditions.

    Moeller, James L.

    1996-01-01

    Discusses contraindications to athletic participation, examining the cardiac, respiratory, and central nervous system conditions that warrant activity disqualification. Provides guidelines about when it is safe for individuals to participate, and discusses the physician's responsibility. (SM)

  4. Megacomplex organization of the oxidative phosphorylation system by structural analysis of respiratory supercomplexes from potato

    Bultema, Jelle B.; Braun, Hans-Peter; Boekema, Egbert J.; Kouřil, Roman

    The individual protein complexes of the oxidative phosphorylation system (OXPHOS complexes 1 to V) specifically interact and form defined supramolecular structures, the so-called "respiratory supercomplexes". Some supercomplexes appear to associate into larger structures, or megacomplexes, such as a

  5. Technical Note: Validation of Odin/SMR limb observations of ozone, comparisons with OSIRIS, POAM III, ground-based and balloon-borne instruments

    F. Jégou

    2008-06-01

    Full Text Available The Odin satellite carries two instruments capable of determining stratospheric ozone profiles by limb sounding: the Sub-Millimetre Radiometer (SMR and the UV-visible spectrograph of the OSIRIS (Optical Spectrograph and InfraRed Imager System instrument. A large number of ozone profiles measurements were performed during six years from November 2001 to present. This ozone dataset is here used to make quantitative comparisons with satellite measurements in order to assess the quality of the Odin/SMR ozone measurements. In a first step, we compare Swedish SMR retrievals version 2.1, French SMR ozone retrievals version 222 (both from the 501.8 GHz band, and the OSIRIS retrievals version 3.0, with the operational version 4.0 ozone product from POAM III (Polar Ozone Atmospheric Measurement. In a second step, we refine the Odin/SMR validation by comparisons with ground-based instruments and balloon-borne observations. We use observations carried out within the framework of the Network for Detection of Atmospheric Composition Change (NDACC and balloon flight missions conducted by the Canadian Space Agency (CSA, the Laboratoire de Physique et de Chimie de l'{}Environnement (LPCE, Orléans, France, and the Service d'Aéronomie (SA, Paris, France. Coincidence criteria were 5° in latitude×10° in longitude, and 5 h in time in Odin/POAM III comparisons, 12 h in Odin/NDACC comparisons, and 72 h in Odin/balloons comparisons. An agreement is found with the POAM III experiment (10–60 km within −0.3±0.2 ppmv (bias±standard deviation for SMR (v222, v2.1 and within −0.5±0.2 ppmv for OSIRIS (v3.0. Odin ozone mixing ratio products are systematically slightly lower than the POAM III data and show an ozone maximum lower by 1–5 km in altitude. The comparisons with the NDACC data (10–34 km for ozonesonde, 10–50 km for lidar, 10–60 for microwave instruments yield a good agreement within −0.15±0.3 ppmv for the SMR data and −0.3±0.3 ppmv

  6. The Herbaspirillum seropedicae SmR1 Fnr orthologs controls the cytochrome composition of the electron transport chain.

    Batista, Marcelo B; Sfeir, Michelle Z T; Faoro, Helisson; Wassem, Roseli; Steffens, Maria B R; Pedrosa, Fábio O; Souza, Emanuel M; Dixon, Ray; Monteiro, Rose A

    2013-01-01

    The transcriptional regulatory protein Fnr, acts as an intracellular redox sensor regulating a wide range of genes in response to changes in oxygen levels. Genome sequencing of Herbaspirillum seropedicae SmR1 revealed the presence of three fnr-like genes. In this study we have constructed single, double and triple fnr deletion mutant strains of H. seropedicae. Transcriptional profiling in combination with expression data from reporter fusions, together with spectroscopic analysis, demonstrates that the Fnr1 and Fnr3 proteins not only regulate expression of the cbb3-type respiratory oxidase, but also control the cytochrome content and other component complexes required for the cytochrome c-based electron transport pathway. Accordingly, in the absence of the three Fnr paralogs, growth is restricted at low oxygen tensions and nitrogenase activity is impaired. Our results suggest that the H. seropedicae Fnr proteins are major players in regulating the composition of the electron transport chain in response to prevailing oxygen concentrations.

  7. 76 FR 62164 - VASRD Improvement Forum-Updating Disability Criteria for the Respiratory System, Cardiovascular...

    2011-10-06

    ... Respiratory System, Cardiovascular System, Hearing Impairment, and Ear, Nose and Throat Diseases AGENCY... System, Cardiovascular System, Hearing Impairment, and Ear, Nose and Throat Diseases. The purpose of this...) the Cardiovascular System (38 CFR 4.100-4.104), (3) the Impairment of Auditory Acuity (38 CFR 4.85 and...

  8. [Measurement of the passive compliance of the total respiratory system in newborn after respiratory insufficiency for risk assessment of respiratory disorders during the first 6 month of life].

    Olechowski, Wiesław; Majorek-Olechowska, Bernadetta

    2010-01-01

    To evaluate the relationships between postnatal passive respiratory compliance (Crs) and development of respiratory disorders during the first 6 month of life in preterm and full-term infants after respiratory insufficiency. The purpose of this study was to investigate whether other relevant neonatal factors, like degree of prematurity, birth weigh, ventilatory conditions, sepsis, and respiratory disease severity affected this relationship. The passive respiratory compliance was measured by the single occlusion technique in 73 preterm infants after respiratory distress syndrome (RDS), 19 full-term infants after congenital pneumonia and 33 healthy full-term infants. Respiratory function measurements were performed by single occlusion technique, during natural sleep, after acute phase of illness, before discharge from neonatal department. Crs was significantly lower in premature newborns newborns who have suffered from a congenital pneumonia (p = 0.0411), than in healthy full-term newborn infants. Premature infants who have undergone sepsis have significantly decreased Crs in relationship with those who did not have this complication (p = 0.0334). Preterm newborns who have suffered pneumonia during treatment of RDS have significantly frequent respiratory problems during the first 6 month of age (p = 0.043). Full-term infants after congenital pneumonia have more but not significantly frequent respiratory problems than healthy term newborns (p = 0.055) in this period. Decreased neonatal Crs wasn't significantly related to respiratory disorders in age of 6 month of life. Prematurity under 36 week of gestational age, low birth weight and suffering from sepsis in premature infants significantly decreased Crs in newborn. Decreased neonatal Crs in premature and full term infants after respiratory insufficiency wasn't significantly related to respiratory disorders during first 6 month of life. This study has showed significantly increase of respiratory problems in this

  9. Physiological system integrations with emphasis on the respiratory-cardiovascular system

    Gallagher, R. R.

    1975-01-01

    The integration of two types of physiological system simulations is presented. The long term model is a circulatory system model which simulates long term blood flow variations and compartmental fluid shifts. The short term models simulate transient phenomena of the respiratory, thermoregulatory, and pulsatile cardiovascular systems as they respond to stimuli such as LBNP, exercise, and environmental gaseous variations. An overview of the interfacing approach is described. Descriptions of the variable interface for long term to short term and between the three short term models are given.

  10. Zastosowanie SMR neurofeedbacku w padaczce lekoopornej

    Marcin Kopka

    2015-08-01

    Full Text Available Padaczka to jedno z najczęstszych schorzeń neurologicznych. Głównym celem leczenia jest zmniejszenie liczby napadów, a co za tym idzie – poprawa jakości życia chorych. Jeżeli dwie próby odpowiednio dobranego, tolerowanego i zastosowanego leczenia farmakologicznego okazują się nieskuteczne, padaczkę określa się mianem lekoopornej. W Polsce na padaczkę choruje około 400 tysięcy osób, u około 30% z nich występuje postać lekooporna. Tylko część pacjentów może skorzystać z leczenia chirurgicznego, istnieje zatem potrzeba poszukiwania alternatywnych metod wspomagania terapii. Jedną z nich wydaje się SMR neurofeedback – metoda treningu oparta na zasadzie biologicznego sprzężenia zwrotnego, czyli dostarczania choremu informacji zwrotnej o zmianach wartości rejestrowanych parametrów fizjologicznych. Gdy podczas treningu rejestrowana jest i wykorzystywana czynność bioelektryczna mózgu (EEG, mówimy o neurofeedbacku. Artykuł ma na celu przedstawienie wiedzy na temat stosowania SMR neurofeedbacku w leczeniu osób z padaczką lekooporną. W 1972 roku Sterman i Friar, zachęceni pozytywnymi wynikami badań na zwierzętach, podjęli pierwszą próbę leczenia za pomocą neurofeedbacku pacjentki z padaczką lekooporną, zaś w ostatniej dekadzie opublikowano wyniki dwóch niezależnych metaanaliz. Wydaje się, że neurofeedback powinien być brany pod uwagę jako terapia uzupełniająca w przypadku chorych z padaczką lekooporną, zwłaszcza gdy zawiodły inne metody. Do potwierdzenia skuteczności neurofeedbacku konieczne są dalsze randomizowane badania kontrolowane – w pracy wskazano ich kierunki.

  11. Simulation of the VISTA SG heat transfer experiment using MIDAS/SMR

    Park, Jong Hwa; Kim, Dong Ha; Chung, Young Jong; Park, Sun Hee; Cho, Seong Won

    2011-01-01

    As the SMART plant was designed with the helical type tubes in the steam generators, the heat transfer model in that geometry has been implemented in the TASS/SMR-S code and used for the safety analysis. The same correlation was implemented in the MIDAS/SMR, which is being used for the severe accident analyses, to model heat transfer at the steam generators. In this study, the VISTA SG experiment with the helical steam generator tube was simulated with MIDAS/SMR to compare the heat transfer rates through the helical tube

  12. SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

    Kim, M; Jung, J; Yoon, D; Shin, H; Kim, S; Suh, T [The catholic university of Korea, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

  13. Development of Non-contact Respiratory Monitoring System for Newborn Using a FG Vision Sensor

    Kurami, Yoshiyuki; Itoh, Yushi; Natori, Michiya; Ohzeki, Kazuo; Aoki, Yoshimitsu

    In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and SpO2 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.

  14. Respiratory system dynamical mechanical properties: modeling in time and frequency domain.

    Carvalho, Alysson Roncally; Zin, Walter Araujo

    2011-06-01

    The mechanical properties of the respiratory system are important determinants of its function and can be severely compromised in disease. The assessment of respiratory system mechanical properties is thus essential in the management of some disorders as well as in the evaluation of respiratory system adaptations in response to an acute or chronic process. Most often, lungs and chest wall are treated as a linear dynamic system that can be expressed with differential equations, allowing determination of the system's parameters, which will reflect the mechanical properties. However, different models that encompass nonlinear characteristics and also multicompartments have been used in several approaches and most specifically in mechanically ventilated patients with acute lung injury. Additionally, the input impedance over a range of frequencies can be assessed with a convenient excitation method allowing the identification of the mechanical characteristics of the central and peripheral airways as well as lung periphery impedance. With the evolution of computational power, the airway pressure and flow can be recorded and stored for hours, and hence continuous monitoring of the respiratory system mechanical properties is already available in some mechanical ventilators. This review aims to describe some of the most frequently used models for the assessment of the respiratory system mechanical properties in both time and frequency domain.

  15. Automated respiratory therapy system based on the ARDSNet protocol with systemic perfusion control

    Pomprapa Anake

    2015-09-01

    Full Text Available A medical expert system of automatic artificial ventilation is set up in a star topology with additional closed-loop hemodynamic control. Arterial blood pressure (MAP is controlled by noradrenaline (NA as a controlling variable. The overall patient-in-the-loop expert system can intensively and intelligently perform a long-term treatment based on the Acute Respiratory Distress Syndrome Network (ARDSNet protocol. Three main goals are actively carried out, namely the stabilization and regulation of oxygenation, plateau pressure and blood pH value. The developed system shows a distinctive experimental result based on a 31.5-kg pig, in order to fulfil the ventilatory goals and to ensure proper systemic perfusion. Hence, this system has enormous potentials to realize a commercial system for individual patient with ARDS.

  16. Time-of-flight small-angle neutron scattering data reduction and analysis at LANSCE with program SMR

    Hjelm, R.P. Jr.; Seeger, P.A.

    1988-01-01

    A user-friendly integrated system, SMR, for the display, reduction and analysis of data from time-of-flight small-angle neutron diffractometers is described. Its purpose is to provide facilities for data display and assessment, and to provide these facilities in near real time. This allows the results of each scattering measurement to be available almost immediately, and enables the user to use the results of a measurement as a basis for other measurements in the same time allocation of the instrument. 8 refs., 10 figs

  17. The Effect of External Vessel Cooling for a 2 inch LOCA Severe Accident Scenario at SMART with MIDAS/SMR

    Park, Jong Hwa; Kim, Dong Ha; Chung, Young Jong; Park, Sun Hee; Cho, Seong Won

    2010-01-01

    KAERI is developing a new concept of reactor that all the main components such as the steam generator, the coolant pumps and the pressurizer are located inside the reactor vessel. This feature may prevent the large size of LOCA. However it is necessary to estimate the hypothetical severe accidents progression for improving the degree of safety and identifying the unknown weakness of the system against an accident. To simulate a hypothetical severe accident for the SMART, we adopt the MIDAS/SMR code which was developed by KAERI

  18. Real-time system for respiratory-cardiac gating in positron tomography

    Klein, G.J.; Reutter, B.W.; Ho, M.H.; Huesman, R.H.; Reed, J.H.

    1998-01-01

    A Macintosh-based signal processing system has been developed to support simultaneous respiratory and cardiac gating on the ECAT EXACT HR PET scanner. Using the Lab-View real-time software environment, the system reads analog inputs from a pneumatic respiratory bellows and an EGG monitor to compute an appropriate histogram memory location for the PET data. Respiratory state is determined by the bellows signal amplitude; cardiac state is based on the time since the last R-wave. These two states are used in a 2D lookup table to determine a combined respiratory-cardiac state. A 4-bit address encoding the selected histogram is directed from the system to the ECAT scanner, which dynamically switches the destination of tomograph events as respiratory-cardiac state changes. to Test the switching efficiency of the combined Macintosh/ECAT system, a rotating emission phantom was built. Acquisitions with 25 msec states while the phantom was rotating at 240 rpm demonstrate the system could effectively stop motion at this rate, with approximately 5 msec switching time between states

  19. SU-E-J-192: Comparative Effect of Different Respiratory Motion Management Systems

    Nakajima, Y; Kadoya, N; Ito, K; Kanai, T; Jingu, K [Tohoku University School of Medicine, Sendai, Miyagi (Japan); Kida, S [Tohoku University Hospital, Sendai City, Miyagi (Japan); Kishi, K; Sato, K [Tohoku University Hospital, Sendai, Miyagi (Japan); Dobashi, S; Takeda, K [Tohoku University, Sendai, Miyagi (Japan)

    2015-06-15

    Purpose: Irregular breathing can influence the outcome of four-dimensional computed tomography imaging for causing artifacts. Audio-visual biofeedback systems associated with patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches), representing simpler visual coaching techniques without guiding waveform are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching to reduce respiratory irregularities by comparing two respiratory management systems. Methods: We collected data from eleven healthy volunteers. Bar and wave models were used as audio-visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. Results: All coaching techniques improved respiratory variation, compared to free breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86, and 0.98 ± 0.47 mm for free breathing, Abches, bar model, and wave model, respectively. Free breathing and wave model differed significantly (p < 0.05). Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18, and 0.17 ± 0.05 s for free breathing, Abches, bar model, and wave model, respectively. Free breathing and all coaching techniques differed significantly (p < 0.05). For variation in both displacement and period, wave model was superior to free breathing, bar model, and Abches. The average reduction in displacement and period RMSE compared with wave model were 27% and 47%, respectively. Conclusion: The efficacy of audio-visual biofeedback to reduce respiratory irregularity compared with Abches. Our results showed that audio-visual biofeedback combined with a wave model can potentially provide clinical benefits in respiratory management

  20. SU-E-J-192: Comparative Effect of Different Respiratory Motion Management Systems

    Nakajima, Y; Kadoya, N; Ito, K; Kanai, T; Jingu, K; Kida, S; Kishi, K; Sato, K; Dobashi, S; Takeda, K

    2015-01-01

    Purpose: Irregular breathing can influence the outcome of four-dimensional computed tomography imaging for causing artifacts. Audio-visual biofeedback systems associated with patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches), representing simpler visual coaching techniques without guiding waveform are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching to reduce respiratory irregularities by comparing two respiratory management systems. Methods: We collected data from eleven healthy volunteers. Bar and wave models were used as audio-visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. Results: All coaching techniques improved respiratory variation, compared to free breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86, and 0.98 ± 0.47 mm for free breathing, Abches, bar model, and wave model, respectively. Free breathing and wave model differed significantly (p < 0.05). Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18, and 0.17 ± 0.05 s for free breathing, Abches, bar model, and wave model, respectively. Free breathing and all coaching techniques differed significantly (p < 0.05). For variation in both displacement and period, wave model was superior to free breathing, bar model, and Abches. The average reduction in displacement and period RMSE compared with wave model were 27% and 47%, respectively. Conclusion: The efficacy of audio-visual biofeedback to reduce respiratory irregularity compared with Abches. Our results showed that audio-visual biofeedback combined with a wave model can potentially provide clinical benefits in respiratory management

  1. Validation of the TASS/SMR-S Code for the PRHRS Condensation Heat Transfer Model

    Jun, In Sub; Yang, Soo Hyoung; Chung, Young Jong; Lee, Won Jae

    2011-01-01

    When some accidents or events are occurred in the SMART, the secondary system is used to remove the core decay heat for the long time such as a feedwater system. But if the feedwater system can't remove the residual core heat because of its malfunction, the core decay heat is removed using the Passive Residual Heat Removal System (PRHRS). The PRHRS is passive type safety system adopted to enhance the safety of the SMART. It can fundamentally eliminate the uncertainty of operator action. TASS/SMR-S (Transient And Setpoint Simulation/ System-integrated Modular Reactor-Safety) code has various heat transfer models reflecting the design features of the SMART. One of the heat transfer models is the PRHRS condensation heat transfer model. The role of this model is to calculate the heat transfer coefficient in the heat exchanger (H/X) tube side using the relevant heat transfer correlations for all of the heat transfer modes. In this paper, the validation of the condensation heat transfer model was carried out using the POSTECH H/X heat transfer test

  2. A System Approach to Navy Medical Education and Training. Appendix 37. Competency Curricula for Respiratory Therapy Assistant and Respiratory Therapy Technician.

    1974-08-31

    instruction. The training aids, like strategies, extend from the traditional references and handout material in the form of a student syllabus to...on careers; select students ; and identify and select faculty. The System Threa sub-systems, as described, comprise the proposed system for Education...of Intermittent Positive Pressure Breathing Treatment . . . . . . . . ... 13 5. Chest Physiotherapy ...... . .. . . . . . 14 6. Respiratory Exercises

  3. A closed-loop model of the respiratory system: focus on hypercapnia and active expiration.

    Yaroslav I Molkov

    Full Text Available Breathing is a vital process providing the exchange of gases between the lungs and atmosphere. During quiet breathing, pumping air from the lungs is mostly performed by contraction of the diaphragm during inspiration, and muscle contraction during expiration does not play a significant role in ventilation. In contrast, during intense exercise or severe hypercapnia forced or active expiration occurs in which the abdominal "expiratory" muscles become actively involved in breathing. The mechanisms of this transition remain unknown. To study these mechanisms, we developed a computational model of the closed-loop respiratory system that describes the brainstem respiratory network controlling the pulmonary subsystem representing lung biomechanics and gas (O2 and CO2 exchange and transport. The lung subsystem provides two types of feedback to the neural subsystem: a mechanical one from pulmonary stretch receptors and a chemical one from central chemoreceptors. The neural component of the model simulates the respiratory network that includes several interacting respiratory neuron types within the Bötzinger and pre-Bötzinger complexes, as well as the retrotrapezoid nucleus/parafacial respiratory group (RTN/pFRG representing the central chemoreception module targeted by chemical feedback. The RTN/pFRG compartment contains an independent neural generator that is activated at an increased CO2 level and controls the abdominal motor output. The lung volume is controlled by two pumps, a major one driven by the diaphragm and an additional one activated by abdominal muscles and involved in active expiration. The model represents the first attempt to model the transition from quiet breathing to breathing with active expiration. The model suggests that the closed-loop respiratory control system switches to active expiration via a quantal acceleration of expiratory activity, when increases in breathing rate and phrenic amplitude no longer provide sufficient

  4. Lost life years due to premature mortality caused by diseases of the respiratory system.

    Maniecka-Bryła, Irena; Paciej-Gołębiowska, Paulina; Dziankowska-Zaborszczyk, Elżbieta; Bryła, Marek

    2018-06-04

    In Poland, as in most other European countries, diseases of the respiratory system are the 4th leading cause of mortality; they are responsible for about 8% of all deaths in the European Union (EU) annually. To assess the socio-economic aspects of mortality, it has become increasingly common to apply potential measures rather than conventionally used ratios. The aim of this study was to analyze years of life lost due to premature deaths caused by diseases of the respiratory system in Poland from 1999 to 2013. The study was based on a dataset of 5,606,516 records, obtained from the death certificates of Polish residents who died between 1999 and 2013. The information on deaths caused by diseases of the respiratory system, i.e., coded as J00-J99 according to the International Statistical Classification of Diseases and Related Health Problems, 10th revision (ICD-10), was analyzed. The Standard Expected Years of Life Lost (SEYLL) indicator was used in the study. In the years 1999-2013, the Polish population suffered 280,519 deaths caused by diseases of the respiratory system (4.69% of all deaths). In the period analyzed, a gradual decrease in the standardized death rate was observed - from 46.31 per 100,000 inhabitants in 1999 to 41.02 in 2013. The dominant causes of death were influenza and pneumonia (J09-J18) and chronic lower respiratory diseases (J40-J47). Diseases of the respiratory system were the cause of 4,474,548.92 lost life years. The Standard Expected Years of Life Lost per person (SEYLLp) was 104.72 per 10,000 males and 52.85 per 10,000 females. The Standard Expected Years of Life Lost per death (SEYLLd) for people who died due to diseases of the respiratory system was 17.54 years of life on average for men and 13.65 years on average for women. The use of the SEYLL indicator provided significant information on premature mortality due to diseases of the respiratory system, indicating the fact that they play a large role in the health status of the Polish

  5. Preliminary study of steam cycle layout and modeling for SMR application

    Lee, Jae Jun; Lee, Won Woong; Kwon, Jinsu; Lee, Jeong Ik

    2017-01-01

    Until recently, a lot of small modular reactor (SMR) concepts such as NuScale, mPower and SMART have been developed and proposed. These reactors have specific features like natural circulation, advanced passive safety system. Center for Autonomous Small Modular Reactor Research (CASMRR) has been researching Autonomous Transportable On-demand reactor Module (ATOM). ATOM has some features such as soluble boron free, passive safety system that utilizes air cooled natural circulation, automatic load following algorithm, development of fuel and structural materials and so on. As a part of the project, a simulation platform is being constructed for thermal hydraulic analysis of the system at steady and transient states and evaluation of thermal margin. Also, this platform will be used for constructing database for autonomous operation. In this paper, some processes for building the platform are introduced. The layout of steam cycle for ATOM is designed using KAIST-CCD, which is an in-house code for the cycle design. The cycle is modeled for simulating the reactor power plant system using MARS-KS. The conceptual power conversion cycle is modeled using MARS-KS. The platform is constructed with the conceptual diagram only. To improve and fill the lack of information, additional design work will be followed and the model will be updated with more details. The more accurate and specific data will be presented during the conference.

  6. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study

    Jeanette Janaina Jaber Lucato

    2009-06-01

    Full Text Available OBJECTIVES: To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION: Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers' humidifying performance. METHODS: Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37°C, a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH was calculated for each setting. RESULTS: Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. CONCLUSIONS: Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers.

  7. Instrumentation for the analysis of respiratory system disorders during sleep: Design and application

    de Melo, Pedro Lopes; de Andrade Lemes, Lucas Neves

    2002-11-01

    Sleep breathing disorders are estimated to be present in 2%-4% of middle-aged adults. Serious adverse consequences, such as systemic arterial hypertension, myocardial infraction, and cerebrovascular disease, can be related to these conditions. Intellectual deficits associated with attention, memory, and problem-solving have also been associated with a poor quality of sleep. The main causes of these disorders are obstructions resulting from repetitive narrowing and closure of the pharyngeal airway, which have been monitored by indirect measurements of temperature, displacement, and other highly invasive procedures. The measurement of mechanical impedance of the respiratory system by the forced oscillation technique (FOT) has recently been suggested to quantify the respiratory obstruction during sleep. It is claimed that the noninvasive and dynamic characteristics of this technique would allow a noninvasive and accurate analysis of these events. In spite of this high scientific and clinical potential, there is no detailed description of a complete instrumentation system to implement this promising technique in sleep studies. In this context, the purpose of this study was twofold: (1) describe the development of a new computer-based system for identification of the mechanical impedance of the respiratory system during sleep by the FOT and (2) evaluate the performance of this device in the description of respiratory events in conditions including no, mild, serious disease, and therapeutic procedures. These evaluations confirmed the desirable features achieved in laboratory tests and the high scientific and clinical potential of this system.

  8. Late-onset Radiologic Findings of Respiratory System Following Sulfur Mustard Exposure

    Mahnaz Amini

    2013-06-01

    Full Text Available Background: Sulfur mustard (SM as a chemical warfare agent, increases permeability of bronchial vessels and damages airway epithelium. SM exposure causes debilitating respiratory complications. This study was designed to evaluate clinical respiratory manifestations, and to compare chest X ray (CXR and high resolution computed tomography (HRCT scan of chest in SM exposed patients with respiratory complaints. Methods:All patients with history of SM exposure who visited Imam Reza Specialized Clinic of Respiratory Diseases from September 2001 to March 2011 were included. Patients with other comorbidities which affect respiratory system were excluded. CXR and chest HRCT scan were performed on the same day and were repeated after 5 years. Clinical and radiologic findings were collected and were compared with each other. Results: In total, 62 male patients with mean age of 53 (6.9, 41-65 were studied. Dyspnea (61 cases; 100%, dry cough (40 cases; 66%, hemoptysis (21 cases; 35% and productive cough (20 cases; 33% were the most common respiratory manifestations. Pulmonary infiltration (51; 83%, pleural thickening (25; 40% and emphysema (16; 26% were the most common findings on CXR. According to HRCT scan, pulmonary infiltration (53; 85%, bronchiolitis obliterans (38; 61% and pleural thickening (36; 58% were the most common findings (Table 2. Repeated radiologic assessments after 5 years showed a few additional findings in HRCT scan, while in about one fifth of CXRs, new pathologic findings were found. Conclusion: Patients with SM exposure experience debilitating respiratory disorders in long term. Repeating CXR in patients who present with subjective symptoms may show new findings; however, repeating HRCT scan is probably not necessary.

  9. Morphogenesis of the rhea (Rhea americana respiratory system in different embryonic and foetal stages

    Renata P. Sousa

    Full Text Available ABSTRACT: The rhea (Rhea americana is an important wild species that has been highlighted in national and international livestock. This research aims to analyse embryo-foetal development in different phases of the respiratory system of rheas. Twenty-three embryos and foetuses were euthanized, fixed and dissected. Fragments of the respiratory system, including the nasal cavity, larynx, trachea, syrinx, bronchi and lungs, were collected and processed for studies using light and scanning electron microscopy. The nasal cavity presented cubic epithelium in the early stages of development. The larynx exhibited typical respiratory epithelium between 27 and 31 days. The trachea showed early formation of hyaline cartilage after 15 days. Syrinx in the mucous membrane of 18-day foetuses consisted of ciliated epithelium in the bronchial region. The main bronchi had ciliated epithelium with goblet cells in the syringeal region. In the lung, the parabronchial stage presented numerous parabronchi between 15 and 21 days. This study allowed the identification of normal events that occur during the development of the rhea respiratory system, an important model that has not previously been described. The information generated here will be useful for the diagnosis of pathologies that affect this organic system, aimed at improving captive production systems.

  10. Contactless respiratory monitoring system for magnetic resonance imaging applications using a laser range sensor

    Krug Johannes W.

    2016-09-01

    Full Text Available During a magnetic resonance imaging (MRI exam, a respiratory signal can be required for different purposes, e.g. for patient monitoring, motion compensation or for research studies such as in functional MRI. In addition, respiratory information can be used as a biofeedback for the patient in order to control breath holds or shallow breathing. To reduce patient preparation time or distortions of the MR imaging system, we propose the use of a contactless approach for gathering information about the respiratory activity. An experimental setup based on a commercially available laser range sensor was used to detect respiratory induced motion of the chest or abdomen. This setup was tested using a motion phantom and different human subjects in an MRI scanner. A nasal airflow sensor served as a reference. For both, the phantom as well as the different human subjects, the motion frequency was precisely measured. These results show that a low cost, contactless, laser-based approach can be used to obtain information about the respiratory motion during an MRI exam.

  11. Research Summary 3-D Computational Fluid Dynamics (CFD) Model Of The Human Respiratory System

    The U.S. EPA’s Office of Research and Development (ORD) has developed a 3-D computational fluid dynamics (CFD) model of the human respiratory system that allows for the simulation of particulate based contaminant deposition and clearance, while being adaptable for age, ethnicity,...

  12. From Head to Toe: Respiratory, Circulatory, and Skeletal Systems. Book 3.

    Wiebe, Arthur, Ed.; And Others

    Designed to supplement curricular programs dealing with the human body, this booklet offers an activity-based, student-oriented approach for middle school teachers and students. Twelve activities focus on principles and skills related to the respiratory, circulatory, and skeletal systems. Each activity consists of student sheets and a teacher's…

  13. Predicting nosocomial lower respiratory tract infections by a risk index based system

    Chen, Yong; Shan, Xue; Zhao, Jingya; Han, Xuelin; Tian, Shuguang; Chen, Fangyan; Su, Xueting; Sun, Yansong; Huang, Liuyu; Grundmann, Hajo; Wang, Hongyuan; Han, Li

    2017-01-01

    Although belonging to one of the most common type of nosocomial infection, there was currently no simple prediction model for lower respiratory tract infections (LRTIs). This study aims to develop a risk index based system for predicting nosocomial LRTIs based on data from a large point-prevalence

  14. Evaluation of Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students

    Paganini, Matteo; Bondì, Michela; Rubini, Alessandro

    2017-01-01

    Ultrasound imaging is a widely used diagnostic technique, whose integration in medical education is constantly growing. The aim of this study was to evaluate chest ultrasound usefulness in teaching respiratory system physiology, students' perception of chest ultrasound integration into a traditional lecture in human physiology, and short-term…

  15. Influence of the viscoelastic properties of the respiratory system on the energetically optimum breathing frequency.

    Bates, J H; Milic-Emili, J

    1993-01-01

    We hypothesized that the viscoelastic properties of the respiratory system should have significant implications for the energetically optimal frequency of breathing, in view of the fact that these properties cause marked dependencies of overall system resistance and elastance on frequency. To test our hypothesis we simulated two models of canine and human respiratory system mechanics during sinusoidal breathing and calculated the inspiratory work (WI) and pressure-time integral (PTI) per minute under both resting and exercise conditions. The two models were a two-compartment viscoelastic model and a single-compartment model. Requiring minute alveolar ventilation to be fixed, we found that both models predicted almost identical optimum breathing frequencies. The calculated PTI was very insensitive to increases in breathing frequency above the optimal frequencies, while WI was found to increase slowly with frequency above its optimum. In contrast, both WI and PTI increased sharply as frequency decreased below their respective optima. A sensitivity analysis showed that the model predictions were very insensitive to the elastance and resistance values chosen to characterize tissue viscoelasticity. We conclude that the WI criterion for choosing the frequency of breathing is compatible with observations in nature, whereas the optimal frequency predictions of the PTI are rather too high. Both criteria allow for a fairly wide margin of choice in frequency above the optimum values without incurring excessive additional energy expenditure. Furthermore, contrary to our expectations, the viscoelastic properties of the respiratory system tissues do not pose a noticeable problem to the respiratory controller in terms of energy expenditure.

  16. Systemic dermatitis and obstructive respiratory syndrome following occupational sensitization to trichloroethylene.

    Raşcu, Agripina; Bucur, Letiţia; Naghi, Eugenia; Drăghici, B

    2003-01-01

    We present a derma-respiratory syndrome in a patient occupationally exposed to trichloroethylene (TCE). At the beginning of its industrial use trichloroethylene was considered harmless. But, in time it showed a high noxious capacity. It produces an important and various pathology, which evolves as acute or chronic disease. The case we present shows that trichloroethylene can induce cutaneous pathology that excels contact dermatitis. It also proves that trichloroethylene can produce systemic effects (obstructive respiratory syndrome). The particularity of the case is based on the succession of the events, first the cutaneous and then the respiratory effects. A long period of time was necessary for the installation of the symptoms (for cutaneous and bronchial sensitization to take place). The case presented is the proof that trichloroethylene's great toxicity cannot be doubted and that the clinical forms due to sensitization to trichloroethylene can be dramatic.

  17. Genome of Herbaspirillum seropedicae strain SmR1, a specialized diazotrophic endophyte of tropical grasses.

    Pedrosa, Fábio O; Monteiro, Rose Adele; Wassem, Roseli; Cruz, Leonardo M; Ayub, Ricardo A; Colauto, Nelson B; Fernandez, Maria Aparecida; Fungaro, Maria Helena P; Grisard, Edmundo C; Hungria, Mariangela; Madeira, Humberto M F; Nodari, Rubens O; Osaku, Clarice A; Petzl-Erler, Maria Luiza; Terenzi, Hernán; Vieira, Luiz G E; Steffens, Maria Berenice R; Weiss, Vinicius A; Pereira, Luiz F P; Almeida, Marina I M; Alves, Lysangela R; Marin, Anelis; Araujo, Luiza Maria; Balsanelli, Eduardo; Baura, Valter A; Chubatsu, Leda S; Faoro, Helisson; Favetti, Augusto; Friedermann, Geraldo; Glienke, Chirlei; Karp, Susan; Kava-Cordeiro, Vanessa; Raittz, Roberto T; Ramos, Humberto J O; Ribeiro, Enilze Maria S F; Rigo, Liu Un; Rocha, Saul N; Schwab, Stefan; Silva, Anilda G; Souza, Eliel M; Tadra-Sfeir, Michelle Z; Torres, Rodrigo A; Dabul, Audrei N G; Soares, Maria Albertina M; Gasques, Luciano S; Gimenes, Ciela C T; Valle, Juliana S; Ciferri, Ricardo R; Correa, Luiz C; Murace, Norma K; Pamphile, João A; Patussi, Eliana Valéria; Prioli, Alberto J; Prioli, Sonia Maria A; Rocha, Carmem Lúcia M S C; Arantes, Olívia Márcia N; Furlaneto, Márcia Cristina; Godoy, Leandro P; Oliveira, Carlos E C; Satori, Daniele; Vilas-Boas, Laurival A; Watanabe, Maria Angélica E; Dambros, Bibiana Paula; Guerra, Miguel P; Mathioni, Sandra Marisa; Santos, Karine Louise; Steindel, Mario; Vernal, Javier; Barcellos, Fernando G; Campo, Rubens J; Chueire, Ligia Maria O; Nicolás, Marisa Fabiana; Pereira-Ferrari, Lilian; Silva, José L da Conceição; Gioppo, Nereida M R; Margarido, Vladimir P; Menck-Soares, Maria Amélia; Pinto, Fabiana Gisele S; Simão, Rita de Cássia G; Takahashi, Elizabete K; Yates, Marshall G; Souza, Emanuel M

    2011-05-01

    The molecular mechanisms of plant recognition, colonization, and nutrient exchange between diazotrophic endophytes and plants are scarcely known. Herbaspirillum seropedicae is an endophytic bacterium capable of colonizing intercellular spaces of grasses such as rice and sugar cane. The genome of H. seropedicae strain SmR1 was sequenced and annotated by The Paraná State Genome Programme--GENOPAR. The genome is composed of a circular chromosome of 5,513,887 bp and contains a total of 4,804 genes. The genome sequence revealed that H. seropedicae is a highly versatile microorganism with capacity to metabolize a wide range of carbon and nitrogen sources and with possession of four distinct terminal oxidases. The genome contains a multitude of protein secretion systems, including type I, type II, type III, type V, and type VI secretion systems, and type IV pili, suggesting a high potential to interact with host plants. H. seropedicae is able to synthesize indole acetic acid as reflected by the four IAA biosynthetic pathways present. A gene coding for ACC deaminase, which may be involved in modulating the associated plant ethylene-signaling pathway, is also present. Genes for hemagglutinins/hemolysins/adhesins were found and may play a role in plant cell surface adhesion. These features may endow H. seropedicae with the ability to establish an endophytic life-style in a large number of plant species.

  18. Genome of Herbaspirillum seropedicae strain SmR1, a specialized diazotrophic endophyte of tropical grasses.

    Fábio O Pedrosa

    2011-05-01

    Full Text Available The molecular mechanisms of plant recognition, colonization, and nutrient exchange between diazotrophic endophytes and plants are scarcely known. Herbaspirillum seropedicae is an endophytic bacterium capable of colonizing intercellular spaces of grasses such as rice and sugar cane. The genome of H. seropedicae strain SmR1 was sequenced and annotated by The Paraná State Genome Programme--GENOPAR. The genome is composed of a circular chromosome of 5,513,887 bp and contains a total of 4,804 genes. The genome sequence revealed that H. seropedicae is a highly versatile microorganism with capacity to metabolize a wide range of carbon and nitrogen sources and with possession of four distinct terminal oxidases. The genome contains a multitude of protein secretion systems, including type I, type II, type III, type V, and type VI secretion systems, and type IV pili, suggesting a high potential to interact with host plants. H. seropedicae is able to synthesize indole acetic acid as reflected by the four IAA biosynthetic pathways present. A gene coding for ACC deaminase, which may be involved in modulating the associated plant ethylene-signaling pathway, is also present. Genes for hemagglutinins/hemolysins/adhesins were found and may play a role in plant cell surface adhesion. These features may endow H. seropedicae with the ability to establish an endophytic life-style in a large number of plant species.

  19. SMR-Based Adaptive Mobility Management Scheme in Hierarchical SIP Networks

    KwangHee Choi

    2014-10-01

    Full Text Available In hierarchical SIP networks, paging is performed to reduce location update signaling cost for mobility management. However, the cost efficiency largely depends on each mobile node’s session-to-mobility-ratio (SMR, which is defined as a ratio of the session arrival rate to the movement rate. In this paper, we propose the adaptive mobility management scheme that can determine the policy regarding to each mobile node’s SMR. Each mobile node determines whether the paging is applied or not after comparing its SMR with the threshold. In other words, the paging is applied to a mobile node when a mobile node’s SMR is less than the threshold. Therefore, the proposed scheme provides a way to minimize signaling costs according to each mobile node’s SMR. We find out the optimal threshold through performance analysis, and show that the proposed scheme can reduce signaling cost than the existing SIP and paging schemes in hierarchical SIP networks.

  20. Simple gas chromatographic system for analysis of microbial respiratory gases

    Carle, G. C.

    1972-01-01

    Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

  1. A new respiratory monitoring and processing system based on Wii remote: proof of principle.

    Peng, Y; Vedam, S; Gao, S; Balter, P

    2013-07-01

    To create a patient respiratory management system and patient self-practice tool using the Wii remote, a widely available consumer hardware product. The Wii remote (Wiimote) (Nintendo, Redmond, WA) contains an infrared (IR) camera that can track up to four spots whose coordinates are reported to a host computer via Bluetooth. The Wiimote is capable of tracking a fiducial box currently used by a commercial monitoring system [Real-time Position Management(TM) (RPM) system, Varian Associates, Palo Alto, CA], if the correct IR source is used. The authors validated the Wiimote tracking by comparing the amplitude and frequency of signals among those reported by Wiimote with known movements from an inhouse servo-driven respiratory simulator, as well as with those measured using the RPM. The simulator comparison was done using standard sinusoid signals with amplitude of 2.0 cm as well as recorded patient respiratory traces. The RPM comparisons were done by simultaneously recording the RPM reflective box position with the Wiimote and the RPM. Timing was compared between these two systems by using the digital beam-on signal from the CT scanner, for the 4DCT to synchronize these acquisitions. The data acquisition rate from the Wiimote was 100.0 ± 0.4 Hz with a version 2.1 Bluetooth adaptor. The standard deviation of the height of the motion extrema was 0.06 and 1.1 mm when comparing those measured by the Wiimote and the servomotor encoder for standard sinusoid signal and prerecorded patient respiratory signal, respectively. The standard deviation of the amplitude of motion extrema between the Wiimote and RPM was 0.9 mm and the timing difference was 253 ms. The performance of Wiimote shows promise for respiratory monitoring for its faster sampling rate as well as the potential optical and GPU abilities. If used with care it can deliver reasonable spatial and temporal accuracy.

  2. The feasibility of the auto tuning respiratory compensation system with ultrasonic image tracking technique.

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Nieh, Shu-Kan; Tien, Der-Chi

    2015-01-01

    The purpose of this study is to assess the feasibility of using the analytical technique of ultrasound images in combination with an auto tumor localization system. During respiration, the activity of breathing in and out causes organs displacement at the lower lobe of the lung, and the maximum displacement range happens in the Superior-Inferior (SI) direction. Therefore, in this study all the tumor positioning is in SI direction under respiratory compensation, in which the compensations are carried out to the organs at the lower lobe and adjacent to the lower lobe of lung.In this research, due to the processes of ultrasound imaging generation, image analysis and signal transmission, when the captured respiratory signals are sent to auto tumor localization system, there was a signal time delay. The total delay time of the entire signal transmission process was 0.254 ± 0.023 seconds (with the lowest standard deviation) after implementing a series of analyses. To compensate for this signal delay time (0.254 ± 0.023 sec), a phase lead compensator (PLC) was designed and built into the auto tumor localization system. By analyzing the impact of the delay time and the respiratory waveforms under different frequencies on the phase lead compensator, an overall system delay time can be configured. Results showed as the respiratory frequency increased, variable value ``a'' and the subsequent gain ``k'' in the controller becomes larger. Moreover, value ``a'' and ``k'' increased as the system delay time increased when the respiratory frequency was fixed. The relationship of value ``a'' and ``k'' to the respiratory frequency can be obtained by using the curve fitting method to compensate for the respiratory motion for tumor localization. Through the comparison of the uncompensated signal and the compensated signal performed by the auto tumor localization system on the simulated respiratory signal, the feasibility of using ultrasound image analysis technology combined with the

  3. SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

    Yan, P; Cheng, S; Chao, C; Jain, A

    2014-01-01

    Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during

  4. Advanced Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) Technical Exchange Meeting

    Smith, Curtis [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-09-01

    During FY13, the INL developed an advanced SMR PRA framework which has been described in the report Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) Detailed Technical Framework Specification, INL/EXT-13-28974 (April 2013). In this framework, the various areas are considered: Probabilistic models to provide information specific to advanced SMRs Representation of specific SMR design issues such as having co-located modules and passive safety features Use of modern open-source and readily available analysis methods Internal and external events resulting in impacts to safety All-hazards considerations Methods to support the identification of design vulnerabilities Mechanistic and probabilistic data needs to support modeling and tools In order to describe this framework more fully and obtain feedback on the proposed approaches, the INL hosted a technical exchange meeting during August 2013. This report describes the outcomes of that meeting.

  5. Field Programmable Gate Array (FPGA Respiratory Monitoring System Using a Flow Microsensor and an Accelerometer

    Mellal Idir

    2017-04-01

    Full Text Available This paper describes a non-invasive system for respiratory monitoring using a Micro Electro Mechanical Systems (MEMS flow sensor and an IMU (Inertial Measurement Unit accelerometer. The designed system is intended to be wearable and used in a hospital or at home to assist people with respiratory disorders. To ensure the accuracy of our system, we proposed a calibration method based on ANN (Artificial Neural Network to compensate the temperature drift of the silicon flow sensor. The sigmoid activation functions used in the ANN model were computed with the CORDIC (COordinate Rotation DIgital Computer algorithm. This algorithm was also used to estimate the tilt angle in body position. The design was implemented on reconfigurable platform FPGA.

  6. On the respiratory mechanics measured by forced oscillation technique in patients with systemic sclerosis.

    Ingrid Almeida Miranda

    Full Text Available BACKGROUND: Pulmonary complications are the most common cause of death and morbidity in systemic sclerosis (SSc. The forced oscillation technique (FOT offers a simple and detailed approach to investigate the mechanical properties of the respiratory system. We hypothesized that SSc may introduce changes in the resistive and reactive properties of the respiratory system, and that FOT may help the diagnosis of these abnormalities. METHODOLOGY/PRINCIPAL FINDINGS: We tested these hypotheses in controls (n = 30 and patients with abnormalities classified using spirometry (n = 52 and pulmonary volumes (n = 29. Resistive data were interpreted with the zero-intercept resistance (Ri and the slope of the resistance (S as a function of frequency. Reactance changes were evaluated by the mean reactance between 4 and 32 Hz (Xm and the dynamic compliance (Crs,dyn. The mechanical load was evaluated using the absolute value of the impedance in 4 Hz (Z4Hz. A compartmental model was used to obtain central (R and peripheral (Rp resistances, and alveolar compliance (C. The clinical usefulness was evaluated by investigating the area under the receiver operating characteristic curve (AUC. The presence of expiratory flow limitation (EFL was also evaluated. For the groups classified using spirometry, SSc resulted in increased values in Ri, R, Rp and Z4Hz (p0.90. In groups classified by pulmonary volume, SSc resulted in reductions in S, Xm, C and Crs,dyn (p0.80. It was also observed that EFL is not common in patients with SSc. CONCLUSIONS/SIGNIFICANCE: This study provides evidence that the respiratory resistance and reactance are changed in SSc. This analysis provides a useful description that is of particular significance for understanding respiratory pathophysiology and to ease the diagnosis of respiratory abnormalities in these patients.

  7. Application of B{sub 4}C/Al{sub 2}O{sub 3} Burnable Absorber Rod to Control Excess Reactivity of SMR

    Muth, Boravy; Hah, C. J. [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-10-15

    Soluble boron in a nuclear reactor coolant is one of the methods to control excess reactivity of the reactor. However, the use of soluble boron also causes some negative effects such as corrosion, more-positive tendency of Moderator Temperature Coefficient (MTC) and the requirement of Chemical Volume Control System (CVCS). One of the conceptual design features of SMR having been developed in Korea is soluble boron- free reactor to eliminate those drawbacks. Control rods and Burnable Absorber (BA) rods can be other methods than soluble to control excess reactivity. WABA (Wet Annular Burnable Absorber) and PYREX are such type. The other type is IFBA (Integral Fuel Burnable Absorber) in which fuel pellet surface is coated with BA. This paper compares nuclear characteristics of three types of BA as well as SLOBA in terms of k-infinite vs. burnup and explain design basis of SLOBA. This paper also presents the application of SLOBA rods to control long-term excess reactivity of SMR. The SMR loaded with SLOBA rods has been developed for the past few years in Korean. It is named as Bandi-50 with design features of 180 MWth, 37 FAs, fuel assembly height of 200 cm. Soluble-boron-free is one of nuclear design requirements of Bandi-50 and is achieved by controlling excess reactivity of the SMR using BAs and control rods only. To achieve this design requirement, LP is carefully determined in such way that CBC should be as low as possible. Fuel assembly cross-sections are generated by CASMO-3, and core depletion calculations are performed by MASTER.

  8. Harmonisation of the acute respiratory infection reporting system in the Czech Republic with the European community networks.

    Kyncl, J.; Paget, W.J.; Havlickova, M.; Kriz, B.

    2005-01-01

    Respiratory virus activity is detected in Europe each winter, yet the precise timing and size of this activity is highly unpredictable. The impact of influenza infection and/or acute respiratory infection in European countries is continuously monitored through a variety of surveillance systems. All

  9. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system

    Chan, Chung; Sinusas, Albert J; Liu, Chi; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa

    2014-01-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory–cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory–cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased

  10. Development of a home screening system for pediatric respiratory sleep studies.

    Foo, Jong Yong Abdiel; Lim, Chu Sing

    2006-12-01

    To develop a simple and portable home screening monitor for sleep-disordered breathing (SDB) in children. In such a system, identifying the respiratory events and occurrences of motional artifacts are two essential elements that can affect the accuracy of the study. Moreover, such a system needs to be easy to set up and user friendly. The proposed system includes the following: electrocardiogram, pulse oximeter, microcontroller-based computation device, and a tri-axial accelerometer. Three physiologic parameters derived with this device were used to identify central (CE) and obstructive (OE) respiratory events. The criteria used were based on documented evidence and compared against corresponding standard polysomnographic scorings. In addition, a module was constructed in conjunction with a RS232 chip to transmit the recorded data to a personal computer. The accelerometer was used as a motion artifact detector. Detectable signals were acquired from the accelerometer when artifacts were induced on the photoplethysmography by motions in three regulated test activities lasting at least 30 seconds each. In classifying respiratory events, the combined use of oxygen saturation, heart rate, and pulse transit time to produce a complex classification (logic OR) showed promise. For OE, the sensitivity and specificity were 0.828 and 0.859, respectively. For CE, these values were 0.868 and 0.762, respectively. The proposed system potentially fulfils the criterion as a home screening tool and can form an indispensable addition to the SDB investigation in the pediatric population.

  11. A versatile hydraulically operated respiratory servo system for ventilation and lung function testing.

    Meyer, M; Slama, H

    1983-09-01

    A description is given of the design and performance of a microcomputer-controlled respiratory servo system that incorporates the characteristics of a mechanical ventilator and also allows the performance of a multitude of test procedures required for assessment of pulmonary function in paralyzed animals. The device consists of a hydraulically operated cylinder-piston assembly and solenoid valves that direct inspiratory and expiratory gas flow and also enable switching to different test gas sources. The system operates as a volume-flow-preset ventilator but may be switched to other operational cycling modes. Gas flow rates may be constant or variable. The system operates as an assister-controller and, combined with a gas analyzer, can function as a "demand" ventilator allowing for set-point control of end-tidal PCO2 and PO2. Complex breathing maneuvers for a variety of single- and multiple-breath lung function tests are automatically performed. Because of the flexibility in selection and timing of respiratory parameters, the system is particularly suitable for respiratory gas studies.

  12. A Wearable Respiratory Biofeedback System Based on Generalized Body Sensor Network

    Liu, Guan-Zheng; Huang, Bang-Yu

    2011-01-01

    Abstract Wearable medical devices have enabled unobtrusive monitoring of vital signs and emerging biofeedback services in a pervasive manner. This article describes a wearable respiratory biofeedback system based on a generalized body sensor network (BSN) platform. The compact BSN platform was tailored for the strong requirements of overall system optimizations. A waist-worn biofeedback device was designed using the BSN. Extensive bench tests have shown that the generalized BSN worked as intended. In-situ experiments with 22 subjects indicated that the biofeedback device was discreet, easy to wear, and capable of offering wearable respiratory trainings. Pilot studies on wearable training patterns and resultant heart rate variability suggested that paced respirations at abdominal level and with identical inhaling/exhaling ratio were more appropriate for decreasing sympathetic arousal and increasing parasympathetic activities. PMID:21545293

  13. Numerical Simulation of Hemodynamic and Physiological Responses of Human Cardiovascular and Respiratory System under Drugs Administration

    Převorovská, Světlana; Maršík, František

    2004-01-01

    Roč. 4, č. 4 (2004), s. 295-304 ISSN 1567-8822 R&D Projects: GA ČR(CZ) GA106/03/1073; GA ČR(CZ) GA106/03/0958 Institutional research plan: CEZ:AV0Z2076919 Keywords : human cardiovascular and respiratory system * baroreflex and chemoreflex control * physiologically based pharmacokinetic model Subject RIV: BK - Fluid Dynamics

  14. Changes in rat respiratory system produced by exposure to exhaust gases of combustion of glycerol.

    Serra, Daniel Silveira; Evangelista, Janaína Serra Azul Monteiro; Zin, Walter Araujo; Leal-Cardoso, José Henrique; Cavalcante, Francisco Sales Ávila

    2017-08-01

    The combustion of residual glycerol to generate heat in industrial processes has been suggested as a cost-effective solution for disposal of this environmental liability. Thus, we investigated the effects of exposure to the exhaust gases of glycerol combustion in the rat respiratory system. We used 2 rats groups, one exposed to the exhaust gases from glycerol combustion (Glycerol), and the other exposed to ambient air (Control). Exposure occurred 5h a day, 5days a week for 13 weeks. We observed statistically changes in all parameters of respiratory system mechanics in vivo. This results was supported by histological analysis and morphometric data, confirming narrower airways and lung parenchimal changes. Variables related to airway resistance (ΔR N ) and elastic properties of the tissue (ΔH), increased after challenge with methacholine. Finally, analysis of lung tissue micromechanics showed statistically increases in all parameters (R, E and hysteresivity). In conclusion, exhaust gases from glycerol combustion were harmful to the respiratory system. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 47 CFR 90.816 - Criteria for comparative 900 MHz SMR renewal proceedings.

    2010-10-01

    ...) Ultimate issue. The ultimate issue in comparative renewal proceedings will be to determine, in light of the... interest, convenience and necessity. (b) Renewal expectancies. The most important comparative factor to be... timetable of the construction of new base sites to meet changes in demand for SMR service; (iii) A...

  16. No effects of successful bidirectional SMR feedback training on objective and subjective sleep in healthy subjects

    Binsch, O.; Wilschut, E.S.; Arns, M.; Bottenheft, C.; Valk, P.J.L.; Vermetten, H.G.J.M.

    2017-01-01

    There is a growing interest in the application of psychophysiological signals in more applied settings. Unidirectional sensory motor rhythm-training (SMR) has demonstrated consistent effects on sleep. In this study the main aim was to analyze to what extent participants could gain voluntary control

  17. Design concepts and safety concerns of the small and medium size reactors (SMR)

    Seul, Kwang Won; Lee, Jae Hun; Kim, Hho Jung

    1998-01-01

    The small and medium size reactors (SMR) and interface facilities such as desalination plant are expected to be located near the population area because of restrictions in transporting the plant products such as fresh water to long distance area. To protect the public around the plant facility from the possible release of radioactive materials, the design development of the SMR is focusing on an enhancement of the safety and reliability as well as the economics. In this study, the major safety concepts of the SMR designs significantly different from the current PWR designs are investigated and the safety concerns applicable to the integrated SMR design of Korea (called SMART), were identified. Those safety issues include the use of proven technology, application of strengthening defense in depth, event categorization and selection, simplification of emergency planning, determination of accident source terms and so on. The efforts to resolve the safety concerns in the design stage will provide an improvement of the safety of the SMART design

  18. Respiratory acidosis

    Ventilatory failure; Respiratory failure; Acidosis - respiratory ... Causes of respiratory acidosis include: Diseases of the airways (such as asthma and COPD ) Diseases of the lung tissue (such as ...

  19. Consideration of the accuracy by variation of respiration in real-time position management respiratory gating system

    Na, Jun Young; Kang, Tae Young; Beak, Geum Mun; Kwon, Gyeong Tae

    2013-01-01

    Respiratory Gated Radiation Therapy (RGRT) has been carried out using RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, varian, USA) in Asan Medical Center. This study was to analyze and evaluate the accuracy of Respiratory Gated Radiation Therapy (RGRT) according to variation of respiration. Making variation of respiration using Motion Phantom:QUASAR Programmable Respiratory Motion Phantom (Moudus Medical Device Inc. CANADA) able to adjust respiration pattern randomly was varying period, amplitude and baseline by analyze 50 patient's respiration of lung and liver cancer. One of the variations of respiration is baseline shift gradually downward per 0.01 cm, 0.03 cm, 0.05 cm. The other variation of respiration is baseline shift accidently downward per 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm. Experiments were performed in the same way that is used RPM Respiratory Gating System (phase gating, usually 30-70% gating) in Asan Medical Center. It was all exposed radiation under one of the conditions of baseline shift gradually downward per 0.01 cm, 0.03 cm, 0.05 cm. Under the other condition of baseline shift accidently downward per 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm equally radiation was exposed. The variations of baseline shifts didn't accurately reflect on phase gating in RPM Respiratory Gating System. This inexactitude makes serious uncertainty in Respiratory Gated Radiation Therapy. So, Must be stabilized breathing of patient before conducting Respiratory Gated Radiation Therapy. also must be monitored breathing of patient in the middle of treatment. If you observe considerable changes of breathing when conducting Respiratory Gated Radiation Therapy. Stopping treatment immediately and then must be need to recheck treatment site using fluoroscopy. If patient's respiration rechecked using fluoroscopy restabilize, it is possible to restart Respiratory Gated Radiation Therapy

  20. MEchatronic REspiratory System SImulator for Neonatal Applications (MERESSINA project: a novel bioengineering goal

    Scaramuzzo RT

    2013-08-01

    Full Text Available Rosa T Scaramuzzo,1,2 Massimiliano Ciantelli,1 Ilaria Baldoli,3 Lisa Bellanti,3 Marzia Gentile,1 Francesca Cecchi,3 Emilio Sigali,1 Selene Tognarelli,3 Paolo Ghirri,1–4 Stefano Mazzoleni,3 Arianna Menciassi,3 Armando Cuttano,1 Antonio Boldrini,1–4 Cecilia Laschi,3 Paolo Dario3 1Centro di Formazione e Simulazione Neonatale "NINA," UO Neonatologia, Azienda Ospedaliera Universitaria Pisana, Pisa, Italy; 2Istituto di Scienze della Vita, 3The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; 4Università di Pisa, Pisa, Italy Abstract: Respiratory function is mandatory for extrauterine life, but is sometimes impaired in newborns due to prematurity, congenital malformations, or acquired pathologies. Mechanical ventilation is standard care, but long-term complications, such as bronchopulmonary dysplasia, are still largely reported. Therefore, continuous medical education is mandatory to correctly manage devices for assistance. Commercially available breathing function simulators are rarely suitable for the anatomical and physiological realities. The aim of this study is to develop a high-fidelity mechatronic simulator of neonatal airways and lungs for staff training and mechanical ventilator testing. The project is divided into three different phases: (1 a review study on respiratory physiology and pathophysiology and on already available single and multi-compartment models; (2 the prototyping phase; and (3 the on-field system validation. Keywords: simulation, lung, newborn, continuous medical education, respiratory system

  1. Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS)

    Kakar, Manish; Nystroem, Haakan; Aarup, Lasse Rye; Noettrup, Trine Jakobi; Olsen, Dag Rune

    2005-01-01

    The quality of radiation therapy delivered for treating cancer patients is related to set-up errors and organ motion. Due to the margins needed to ensure adequate target coverage, many breast cancer patients have been shown to develop late side effects such as pneumonitis and cardiac damage. Breathing-adapted radiation therapy offers the potential for precise radiation dose delivery to a moving target and thereby reduces the side effects substantially. However, the basic requirement for breathing-adapted radiation therapy is to track and predict the target as precisely as possible. Recent studies have addressed the problem of organ motion prediction by using different methods including artificial neural network and model based approaches. In this study, we propose to use a hybrid intelligent system called ANFIS (the adaptive neuro fuzzy inference system) for predicting respiratory motion in breast cancer patients. In ANFIS, we combine both the learning capabilities of a neural network and reasoning capabilities of fuzzy logic in order to give enhanced prediction capabilities, as compared to using a single methodology alone. After training ANFIS and checking for prediction accuracy on 11 breast cancer patients, it was found that the RMSE (root-mean-square error) can be reduced to sub-millimetre accuracy over a period of 20 s provided the patient is assisted with coaching. The average RMSE for the un-coached patients was 35% of the respiratory amplitude and for the coached patients 6% of the respiratory amplitude

  2. Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS)

    Kakar, Manish [Department of Radiation Biology, Norwegian Radium Hospital, Montebello, 0310 Oslo (Norway); Nystroem, Haakan [Department of Radiation Oncology, The Finsen Centre, Rigshospitalet, Copenhagen (Denmark); Aarup, Lasse Rye [Department of Radiation Oncology, The Finsen Centre, Rigshospitalet, Copenhagen (Denmark); Noettrup, Trine Jakobi [Department of Radiation Oncology, The Finsen Centre, Rigshospitalet, Copenhagen (Denmark); Olsen, Dag Rune [Department of Radiation Biology, Norwegian Radium Hospital, Montebello, 0310 Oslo (Norway); Department of Medical Physics and Technology, Norwegian Radium Hospital, Oslo (Norway); Department of Physics, University of Oslo (Norway)

    2005-10-07

    The quality of radiation therapy delivered for treating cancer patients is related to set-up errors and organ motion. Due to the margins needed to ensure adequate target coverage, many breast cancer patients have been shown to develop late side effects such as pneumonitis and cardiac damage. Breathing-adapted radiation therapy offers the potential for precise radiation dose delivery to a moving target and thereby reduces the side effects substantially. However, the basic requirement for breathing-adapted radiation therapy is to track and predict the target as precisely as possible. Recent studies have addressed the problem of organ motion prediction by using different methods including artificial neural network and model based approaches. In this study, we propose to use a hybrid intelligent system called ANFIS (the adaptive neuro fuzzy inference system) for predicting respiratory motion in breast cancer patients. In ANFIS, we combine both the learning capabilities of a neural network and reasoning capabilities of fuzzy logic in order to give enhanced prediction capabilities, as compared to using a single methodology alone. After training ANFIS and checking for prediction accuracy on 11 breast cancer patients, it was found that the RMSE (root-mean-square error) can be reduced to sub-millimetre accuracy over a period of 20 s provided the patient is assisted with coaching. The average RMSE for the un-coached patients was 35% of the respiratory amplitude and for the coached patients 6% of the respiratory amplitude.

  3. Evaluation of respiratory parameters in minimally processed lettuce grown under organic or conventional system

    Júlio César Mello

    2010-12-01

    Full Text Available The increased preference for minimally processed vegetables has been attributed to the health benefits associated with fresh produce and the demand for ready-to-eat salads. In this paper, lettuce (Lactuca sativa L. was evaluated for the effects of different cropping systems on the respiratory properties. Lettuce was packaged in low density polyethylene bags and stored in a refrigerator at 4 ºC. The concentration of carbon dioxide and oxygen inside the package was monitored during the storage at zero, three, six, eight, ten and twelve days by gas chromatography. Dry matter variation was measured gravimetrically up to day fourteen of storage. Values of respiratory rate for conventional lettuce increased from day 1 to 3 and remained low, while respiratory rate of the organic lettuce increased three-fold up to day 8, stabilizing at a high level. Variation in dry matter during storage also resulted from differences between the two cultivation systems. The highest content of dry matter was achieved by organic lettuce.

  4. MEchatronic REspiratory System SImulator for Neonatal Applications (MERESSINA) project: a novel bioengineering goal

    Scaramuzzo, Rosa T; Ciantelli, Massimiliano; Baldoli, Ilaria; Bellanti, Lisa; Gentile, Marzia; Cecchi, Francesca; Sigali, Emilio; Tognarelli, Selene; Ghirri, Paolo; Mazzoleni, Stefano; Menciassi, Arianna; Cuttano, Armando; Boldrini, Antonio; Laschi, Cecilia; Dario, Paolo

    2013-01-01

    Respiratory function is mandatory for extrauterine life, but is sometimes impaired in newborns due to prematurity, congenital malformations, or acquired pathologies. Mechanical ventilation is standard care, but long-term complications, such as bronchopulmonary dysplasia, are still largely reported. Therefore, continuous medical education is mandatory to correctly manage devices for assistance. Commercially available breathing function simulators are rarely suitable for the anatomical and physiological realities. The aim of this study is to develop a high-fidelity mechatronic simulator of neonatal airways and lungs for staff training and mechanical ventilator testing. The project is divided into three different phases: (1) a review study on respiratory physiology and pathophysiology and on already available single and multi-compartment models; (2) the prototyping phase; and (3) the on-field system validation. PMID:23966804

  5. Consecutive Food and Respiratory Allergies Amplify Systemic and Gut but Not Lung Outcomes in Mice.

    Bouchaud, Gregory; Gourbeyre, Paxcal; Bihouée, Tiphaine; Aubert, Phillippe; Lair, David; Cheminant, Marie-Aude; Denery-Papini, Sandra; Neunlist, Michel; Magnan, Antoine; Bodinier, Marie

    2015-07-22

    Epidemiological data suggest a link between food allergies and the subsequent development of asthma. Although this progression may result from the additional effects of exposure to multiple allergens, whether both allergies amplify each other's effects remains unknown. This study investigated whether oral exposure to food allergens influences the outcomes of subsequent respiratory exposure to an asthma-inducing allergen. Mice were sensitized and orally challenged with wheat (FA) and then exposed to house dust mite (HDM) extract (RA). Immunoglobulin (Ig), histamine, and cytokine levels were assayed by ELISA. Intestinal and lung physiology was assessed. Ig levels, histamine release, and cytokine secretion were higher after exposure to both allergens than after separate exposure to each. Intestinal permeability was higher, although airway hyper-responsiveness and lung inflammation remained unchanged. Exposure to food and respiratory allergens amplifies systemic and gut allergy-related immune responses without any additional effect on lung function and inflammation.

  6. Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer

    Song, Heung Kwon; Kwon, Kyung Tae; Park, Cheol Su; Yang, Oh Nam; Kim, Min Su; Kim, Jeong Man [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2005-09-15

    For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient no 1, motion of GTV was reduced to 2.6 mm in treatment phases (30-60%), while that was 9.4 mm in full phases (0-90%) and for patient no 2, it was reduced to 2.3 mm in treatment phases (30-70%), while it was 11.7 mm in full phases (0-90%). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  7. Upper respiratory tract (image)

    The major passages and structures of the upper respiratory tract include the nose or nostrils, nasal cavity, mouth, throat (pharynx), and voice box (larynx). The respiratory system is lined with a mucous membrane that ...

  8. School absence and treatment in school children with respiratory symptoms in the Netherlands: Data from the Child Health Monitoring System

    Spee-van Der Wekke, J.; Meulmeester, J.F.; Radder, J.J.; Verloove-Vanhorick, S.P.

    1998-01-01

    Study objective - To assess the prevalence of respiratory problems, and the relation of these problems with school attendance, medicine use, and medical treatment. Design - The Child Health Monitoring System. Setting - Nineteen public health services across the Netherlands. Participants - 5186

  9. The Effects of Leucine, Zinc, and Chromium Supplements on Inflammatory Events of the Respiratory System in Type 2 Diabetic Rats

    Kolahian, Saeed; Sadri, Hassan; Shahbazfar, Amir Ali; Amani, Morvarid; Mazadeh, Anis; Mirani, Mehdi

    2015-01-01

    Diabetes mellitus is a major cause of serious micro- and macrovascular diseases that affect nearly every system in the body, including the respiratory system. Non-enzymatic protein glycation due to hyperglycaemic stress has fundamental implications due to the large capillary network and amount of connective tissue in the lung. The current study was designed to determine whether leucine, zinc, and chromium supplementations influence the function and histological structure of the respiratory tr...

  10. Particle deposition due to turbulent diffusion in the upper respiratory system

    Hamill, P.

    1979-01-01

    Aerosol deposition in the upper respiratory system (trachea to segmental bronchi) is considered and the importance of turbulent diffusion as a deposition mechanism is evaluated. It is demonstrated that for large particles (diameter greater than about 5 microns), turbulent diffusion is the dominant deposition mechanism in the trachea. Conditions under which turbulent diffusion may be important in successive generations of the pulmonary system are determined. The probability of particle deposition is compared with probabilities of deposition, as determined by the equations generally used in regional deposition models. The analysis is theoretical; no new experimental data is presented.

  11. Effects of Long-Term Dust Exposure on Human Respiratory System Health in Minqin County, China.

    Wang, Jinyu; Li, Sheng; Wang, Shigong; Shang, Kezheng

    2015-01-01

    The aim of this study was to assess the effects of long-term sand dust exposure on human respiratory health. Dust events break out frequently in Minqin County, northwest China, whereas Pingliang City, northwest China, is rarely influenced by dust events. Therefore, Minqin and Pingliang were selected as sand dust exposure region and control area, respectively. The incidence of respiratory system diseases and symptoms was determined through a structured respiratory health questionnaire (ATS-DLD-78-A) and personal interviews. The subjects comprised 728 farmers (Minqin, 424; Pingliang, 304) aged 40 years or older, who had nondocumented occupational history to industrial dust exposure. Prevalences (odds ratio [OR], 95% confidence interval [CI]) of chronic rhinitis, chronic bronchitis, and chronic cough increased 9.6% (3.141, 1.776-5.555), 7.5% (2.468, 1.421-4.286), and 10.2% (1.787, 1.246-2.563) in Minqin comparison with Pingliang, respectively, and the differences were significant (p <.01).

  12. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (Pvolume during the isovolume maneuver (standard deviationpulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  13. The effect of environmental pollution on the respiratory system of lignite miners: a diachronic study.

    Sichletidis, L; Tsiotsios, I; Chloros, D; Daskalopoulou, E; Ziomas, I; Michailidis, K; Kottakis, I; Konstantinidis, T H; Palladas, P

    2004-01-01

    It is not known whether working in surface lignite mines can cause x-ray lesions or disorders of respiratory function. The aim of the study was to investigate the diachronic impact of environmental pollution on the respiratory system of lignite miners at mines in Eordea, Greece. Cases of 199 workers (Group A) residing permanently in the Eordea valley and 151 (Group B) living outside the Eordea valley were studied during Phase I and then re-examined after three years (Phase II). These cases were compared to those of 71 office workers living in Eordea valley (Group C) and to 96 living in Grevena, a region without pollution (Group D). The study included the completion of the MRC questionnaire for the detection of respiratory diseases, pulmonary function tests, measurement of diffusion capacity, otorhinolaryngologic examination, rhinomanonetry as well as chest and paranasal cavity X-rays. Chronic bronchitis was reported by 26.8%, 24.8%, 17.9% and 10.6% respectively of the subjects of groups A, B, C and D according to the answers of the questionnaire (pmines under conditions of excessive pollution by airborne contaminants have a high prevalence of atrophic rhinitis and, in addition to other standard examinations, should undergo rhinomanometry testing and X-ray imaging of the paranasal cavities.

  14. Next Generation Respiratory Viral Vaccine System: Advanced and Emerging Bioengineered Human Lung Epithelia Model (HLEM) Organoid Technology

    Goodwin, Thomas J.; Schneider, Sandra L.; MacIntosh, Victor; Gibbons, Thomas F.

    2010-01-01

    Acute respiratory infections, including pneumonia and influenza, are the S t" leading cause of United States and worldwide deaths. Newly emerging pathogens signaled the need for an advanced generation of vaccine technology.. Human bronchial-tracheal epithelial tissue was bioengineered to detect, identify, host and study the pathogenesis of acute respiratory viral disease. The 3-dimensional (3D) human lung epithelio-mesechymal tissue-like assemblies (HLEM TLAs) share characteristics with human respiratory epithelium: tight junctions, desmosomes, microvilli, functional markers villin, keratins and production of tissue mucin. Respiratory Syntial Virus (RSV) studies demonstrate viral growth kinetics and membrane bound glycoproteins up to day 20 post infection in the human lung-orgainoid infected cell system. Peak replication of RSV occurred on day 10 at 7 log10 particles forming units per ml/day. HLEM is an advanced virus vaccine model and biosentinel system for emergent viral infectious diseases to support DoD global surveillance and military readiness.

  15. Simulation of the condensation experiment for the SG primary of SMART with MIDAS/SMR

    Park, Jong Hwa; Kim, Dong Ha; Chung, Young Jong; Park, Sun Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seong Won [Korea Radiation Technology Institute Co., Daejeon (Korea, Republic of)

    2012-05-15

    SMART is new concept of reactor that all the main components such as the steam generator, the coolant pumps and the pressurizer are located inside the reactor vessel. MIDAS/SMR V1.0.3 code has been used for estimating the severe accident from SMART. SMART has the SG tube with helical shape that is different from that of PWR. MIDAS code has the condensation model for the both sides of surfaces from the various kinds of geometry. But it does not have the condensation model for the helical type of tube. In this study, the condensation experiment for the outer surface of the SG tube in SMART that was performed by Po-Hang university was simulated with MIDAS/SMR under the assumption of straight pipe. The simulation results showed well predictions of the amount of heat removal from the SG tube primary side and thermal hydraulic parameters

  16. Simulation of the condensation experiment for the SG primary of SMART with MIDAS/SMR

    Park, Jong Hwa; Kim, Dong Ha; Chung, Young Jong; Park, Sun Hee; Cho, Seong Won

    2012-01-01

    SMART is new concept of reactor that all the main components such as the steam generator, the coolant pumps and the pressurizer are located inside the reactor vessel. MIDAS/SMR V1.0.3 code has been used for estimating the severe accident from SMART. SMART has the SG tube with helical shape that is different from that of PWR. MIDAS code has the condensation model for the both sides of surfaces from the various kinds of geometry. But it does not have the condensation model for the helical type of tube. In this study, the condensation experiment for the outer surface of the SG tube in SMART that was performed by Po-Hang university was simulated with MIDAS/SMR under the assumption of straight pipe. The simulation results showed well predictions of the amount of heat removal from the SG tube primary side and thermal hydraulic parameters

  17. Gap Conductance model Validation in the TASS/SMR-S code using MARS code

    Ahn, Sang Jun; Yang, Soo Hyung; Chung, Young Jong; Lee, Won Jae

    2010-01-01

    Korea Atomic Energy Research Institute (KAERI) has been developing the TASS/SMR-S (Transient and Setpoint Simulation/Small and Medium Reactor) code, which is a thermal hydraulic code for the safety analysis of the advanced integral reactor. An appropriate work to validate the applicability of the thermal hydraulic models within the code should be demanded. Among the models, the gap conductance model which is describes the thermal gap conductivity between fuel and cladding was validated through the comparison with MARS code. The validation of the gap conductance model was performed by evaluating the variation of the gap temperature and gap width as the changed with the power fraction. In this paper, a brief description of the gap conductance model in the TASS/SMR-S code is presented. In addition, calculated results to validate the gap conductance model are demonstrated by comparing with the results of the MARS code with the test case

  18. Low power modular power generating reactors or Small Modular Reactors (SMR)

    Chenais, Jacques

    2016-01-01

    Electronuclear reactors were small reactors at the beginning, and then tend to be always bigger and more powerful, but since some recent times, several countries specialized in reactor design and fabrication (USA, Russia, China, and South Korea) have been developing Small Modular Reactors (SMR) of less than 300 MW. As France has already produced feasibility studies and is about to launch a SMR development programme, the author comments some specific aspects of this new architecture of reactors, characterises the targeted markets, gives an overview of the various more or less advanced existing concepts: a floating barge in Russia, the SMART 100 MW project in South Korea, several concepts in the USA (the mPower 125 MW, the NuScale 45 MW, the Westinghouse 225 MW, and the HI-SMUR 160 MW projects), the ACP 100 MW in China, the CAREM 27 MW in Argentina. French projects developed by the CEA, EDF, Areva and DCNS are then presented

  19. Inhalation method for delivery of nanoparticles to the Drosophila respiratory system for toxicity testing

    Posgai, Ryan; Ahamed, Maqusood [Department of Biology, University of Dayton, Dayton, OH, 45469-2320 (United States); Hussain, Saber M. [Applied Biotechnology Branch, Human Effectiveness Directorate Air Force Research Laboratory/RHBP, Wright-Patterson Air Force Base, OH, 45433 (United States); Rowe, John J. [Department of Biology, University of Dayton, Dayton, OH, 45469-2320 (United States); Nielsen, Mark G., E-mail: Mark.Nielsen@notes.udayton.edu [Department of Biology, University of Dayton, Dayton, OH, 45469-2320 (United States)

    2009-12-20

    The growth of the nanotechnology industry and subsequent proliferation of nanoparticle types present the need to rapidly assess nanoparticle toxicity. We present a novel, simple and cost-effective nebulizer-based method to deliver nanoparticles to the Drosophila melanogaster respiratory system, for the purpose of toxicity testing. FluoSpheres (registered) , silver, and CdSe/ZnS nanoparticles of different sizes were effectively aerosolized, showing the system is capable of functioning with a wide range of nanoparticle types and sizes. Red fluorescent CdSe/ZnS nanoparticles were successfully delivered to the fly respiratory system, as visualized by fluorescent microscopy. Silver coated and uncoated nanoparticles were delivered in a toxicity test, and induced Hsp70 expression in flies, confirming the utility of this model in toxicity testing. This is the first method developed capable of such delivery, provides the advantage of the Drosophila health model, and can serve as a link between tissue culture and more expensive mammalian models in a tiered toxicity testing strategy.

  20. Pediatric respiratory and systemic effects of chronic air pollution exposure: nose, lung, heart, and brain pathology.

    Calderón-Garcidueñas, Lilian; Franco-Lira, Maricela; Torres-Jardón, Ricardo; Henriquez-Roldán, Carlos; Barragán-Mejía, Gerardo; Valencia-Salazar, Gildardo; González-Maciel, Angelica; Reynoso-Robles, Rafael; Villarreal-Calderón, Rafael; Reed, William

    2007-01-01

    Exposures to particulate matter and gaseous air pollutants have been associated with respiratory tract inflammation, disruption of the nasal respiratory and olfactory barriers, systemic inflammation, production of mediators of inflammation capable of reaching the brain and systemic circulation of particulate matter. Mexico City (MC) residents are exposed to significant amounts of ozone, particulate matter and associated lipopolysaccharides. MC dogs exhibit brain inflammation and an acceleration of Alzheimer's-like pathology, suggesting that the brain is adversely affected by air pollutants. MC children, adolescents and adults have a significant upregulation of cyclooxygenase-2 (COX2) and interleukin-1beta (IL-1beta) in olfactory bulb and frontal cortex, as well as neuronal and astrocytic accumulation of the 42 amino acid form of beta -amyloid peptide (Abeta 42), including diffuse amyloid plaques in frontal cortex. The pathogenesis of Alzheimer's disease (AD) is characterized by brain inflammation and the accumulation of Abeta 42, which precede the appearance of neuritic plaques and neurofibrillary tangles, the pathological hallmarks of AD. Our findings of nasal barrier disruption, systemic inflammation, and the upregulation of COX2 and IL-1beta expression and Abeta 42 accumulation in brain suggests that sustained exposures to significant concentrations of air pollutants such as particulate matter could be a risk factor for AD and other neurodegenerative diseases.

  1. Inhalation method for delivery of nanoparticles to the Drosophila respiratory system for toxicity testing

    Posgai, Ryan; Ahamed, Maqusood; Hussain, Saber M.; Rowe, John J.; Nielsen, Mark G.

    2009-01-01

    The growth of the nanotechnology industry and subsequent proliferation of nanoparticle types present the need to rapidly assess nanoparticle toxicity. We present a novel, simple and cost-effective nebulizer-based method to deliver nanoparticles to the Drosophila melanogaster respiratory system, for the purpose of toxicity testing. FluoSpheres (registered) , silver, and CdSe/ZnS nanoparticles of different sizes were effectively aerosolized, showing the system is capable of functioning with a wide range of nanoparticle types and sizes. Red fluorescent CdSe/ZnS nanoparticles were successfully delivered to the fly respiratory system, as visualized by fluorescent microscopy. Silver coated and uncoated nanoparticles were delivered in a toxicity test, and induced Hsp70 expression in flies, confirming the utility of this model in toxicity testing. This is the first method developed capable of such delivery, provides the advantage of the Drosophila health model, and can serve as a link between tissue culture and more expensive mammalian models in a tiered toxicity testing strategy.

  2. SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Suh, T; Kim, S

    2015-01-01

    Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R

  3. SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States)

    2015-06-15

    Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R

  4. The Role and Immunobiology of Eosinophils in the Respiratory System: a Comprehensive Review.

    Eng, Stephanie S; DeFelice, Magee L

    2016-04-01

    The eosinophil is a fully delineated granulocyte that disseminates throughout the bloodstream to end-organs after complete maturation in the bone marrow. While the presence of eosinophils is not uncommon even in healthy individuals, these granulocytes play a central role in inflammation and allergic processes. Normally appearing in smaller numbers, higher levels of eosinophils in the peripheral blood or certain tissues typically signal a pathologic process. Eosinophils confer a beneficial effect on the host by enhancing immunity against molds and viruses. However, tissue-specific elevation of eosinophils, particularly in the respiratory system, can cause a variety of short-term symptoms and may lead to long-term sequelae. Eosinophils often play a role in more commonly encountered disease processes, such as asthma and allergic responses in the upper respiratory tract. They are also integral in the pathology of less common diseases including eosinophilic pneumonia, allergic bronchopulmonary aspergillosis, hypersensitivity pneumonitis, and drug reaction with eosinophilia and systemic symptoms. They can be seen in neoplastic disorders or occupational exposures as well. The involvement of eosinophils in pulmonary disease processes can affect the method of diagnosis and the selection of treatment modalities. By analyzing the complex interaction between the eosinophil and its environment, which includes signaling molecules and tissues, different therapies have been discovered and created in order to target disease processes at a cellular level. Innovative treatments such as mepolizumab and benralizumab will be discussed. The purpose of this article is to further explore the topic of eosinophilic presence, activity, and pathology in the respiratory tract, as well as discuss current and future treatment options through a detailed literature review.

  5. Analysis of radiation safety for Small Modular Reactor (SMR) on PWR-100 MWe type

    Udiyani, P. M.; Husnayani, I.; Deswandri; Sunaryo, G. R.

    2018-02-01

    Indonesia as an archipelago country, including big, medium and small islands is suitable to construction of Small Medium/Modular reactors. Preliminary technology assessment on various SMR has been started, indeed the SMR is grouped into Light Water Reactor, Gas Cooled Reactor, and Solid Cooled Reactor and from its site it is group into Land Based reactor and Water Based Reactor. Fukushima accident made people doubt about the safety of Nuclear Power Plant (NPP), which impact on the public perception of the safety of nuclear power plants. The paper will describe the assessment of safety and radiation consequences on site for normal operation and Design Basis Accident postulation of SMR based on PWR-100 MWe in Bangka Island. Consequences of radiation for normal operation simulated for 3 units SMR. The source term was generated from an inventory by using ORIGEN-2 software and the consequence of routine calculated by PC-Cream and accident by PC Cosyma. The adopted methodology used was based on site-specific meteorological and spatial data. According to calculation by PC-CREAM 08 computer code, the highest individual dose in site area for adults is 5.34E-02 mSv/y in ESE direction within 1 km distance from stack. The result of calculation is that doses on public for normal operation below 1mSv/y. The calculation result from PC Cosyma, the highest individual dose is 1.92.E+00 mSv in ESE direction within 1km distance from stack. The total collective dose (all pathway) is 3.39E-01 manSv, with dominant supporting from cloud pathway. Results show that there are no evacuation countermeasure will be taken based on the regulation of emergency.

  6. Shutting down sensorimotor interferences after stroke: A proof-of-principle SMR neurofeedback study

    Johanna Louise Reichert

    2016-07-01

    Full Text Available Introduction: Neurofeedback training aims at learning self-regulation of brain activity underlying cognitive, emotional or physiological functions. Despite of promising investigations on neurofeedback as a tool for cognitive rehabilitation in neurological diseases, such as after stroke, there is still a lack of research on feasibility and efficiency of neurofeedback in this field. Methods: The present study aimed at investigating behavioral and electrophysiological effects of 10 sessions of sensorimotor rhythm (SMR neurofeedback in a 74-year-old stroke patient (UG20. Based on previous results in healthy young participants, we hypothesized that SMR neurofeedback leads to a decrease in sensorimotor interferences and improved stimulus processing, reflected by changes in event-related potentials and electrophysiological coherence. To assess whether UG20 benefited from the training as much as healthy persons of a similar age, a healthy control group of N = 10 elderly persons was trained as well. Before and after neurofeedback training, participants took part in a multichannel EEG measurement conducted during a nonverbal and a verbal learning task. Results: Both UG20 and the healthy controls were able to regulate their SMR activity during neurofeedback training. Moreover, in a nonverbal learning task, changes in event-related potentials and coherence were observed after training: UG20 showed a better performance in the nonverbal learning task and a higher P3 amplitude after training than before, and coherence between central and parietal electrodes decreased after training. The control group also showed a behavioral improvement in the nonverbal learning task and tendencies for higher P3 amplitudes and decreased central-parietal coherence after training. Single-case analyses indicated that the changes observed in UG20 were not smaller than the changes in healthy controls. Conclusions: Neurofeedback can be successfully applied in a stroke patient and in

  7. Shutting Down Sensorimotor Interferences after Stroke: A Proof-of-Principle SMR Neurofeedback Study

    Reichert, Johanna L.; Kober, Silvia E.; Schweiger, Daniela; Grieshofer, Peter; Neuper, Christa; Wood, Guilherme

    2016-01-01

    Introduction: Neurofeedback training aims at learning self-regulation of brain activity underlying cognitive, emotional or physiological functions. Despite of promising investigations on neurofeedback as a tool for cognitive rehabilitation in neurological diseases, such as after stroke, there is still a lack of research on feasibility and efficiency of neurofeedback in this field. Methods: The present study aimed at investigating behavioral and electrophysiological effects of 10 sessions of sensorimotor rhythm (SMR) neurofeedback in a 74-years-old stroke patient (UG20). Based on previous results in healthy young participants, we hypothesized that SMR neurofeedback leads to a decrease in sensorimotor interferences and improved stimulus processing, reflected by changes in event-related potentials (ERPs) and electrophysiological coherence. To assess whether UG20 benefited from the training as much as healthy persons of a similar age, a healthy control group of N = 10 elderly persons was trained as well. Before and after neurofeedback training, participants took part in a multichannel electroencephalography measurement conducted during a non-verbal and a verbal learning task. Results: Both UG20 and the healthy controls were able to regulate their SMR activity during neurofeedback training. Moreover, in a non-verbal learning task, changes in ERPs and coherence were observed after training: UG20 showed a better performance in the non-verbal learning task and a higher P3 amplitude after training than before, and coherence between central and parietal electrodes decreased after training. The control group also showed a behavioral improvement in the non-verbal learning task and tendencies for higher P3 amplitudes and decreased central-parietal coherence after training. Single-case analyses indicated that the changes observed in UG20 were not smaller than the changes in healthy controls. Conclusion: Neurofeedback can be successfully applied in a stroke patient and in healthy

  8. The production of cellulosic ethanol using SMR. A prefeasibility study for the Italian scenario

    Locatelli, Giorgio; Mancini, Mauro

    2011-01-01

    Small Medium Reactors (SMR) can play an important role in the global nuclear renaissance coupling the production of Electrical Energy (EE) with by-products useful to increase their economic attractiveness and enhance the public acceptability. Light Water Reactors (LWR) have an average thermal efficiency of about 33%-35%, therefore two third of the thermal energy produced by the nuclear reaction is usually wasted. Nowadays there are industries able to use this thermal energy in an efficient way. Among the other the production of cellulosic ethanol seems one of the most attractive for the coupling with a nuclear power plant. This industry can exploit two by-products of a nuclear reactor: the wide area around the plant (the so called Emergency Planning Zone - EPZ) and the residual thermal energy post turbines. Cellulosic ethanol is a bio-fuel produced from non-edible parts of plants or wood. It is produced from lignocellulose the material composing much of the mass of plants. Production of ethanol (that can be used as a fuel) from lignocellulose can avoid the usage of food grain or precious vegetables usable for the human nutrition, but requires an enormous amount of heat in the production process. A SMR can be the ideal source of this thermal energy. The paper presents a prefeasibility study with the economic and strategic assessment of coupling an SMR and a cellulosic ethanol plant in the north of Italy. After an introduction on the ethanol production the papers describe the market of this product and the production process. Then it provides the cost estimation of coupling the SMR with the production plant. The results point out as this combination can be very attractive to enhance the production of ethanol since is really cost competitive and does not produce any green house gases (GHG). (author)

  9. Business Case Analysis Of Small Modular Reactors (SMR) For DOD Assured Power

    2017-12-01

    in SMR technology for energy security. Looking at the explicit costs and benefits of the investment using net present value (NPV) metrics can inform ...its useful life (Energy Information Administration [EIA], 2016). The old infrastructure can be attributed to the challenges that exist for...indicates that a dollar today is worth more than a dollar tomorrow. The discount rate accounts for whether an investor would obtain a better return on

  10. Potential toxicity and safety evaluation of nanomaterials for the respiratory system and lung cancer

    Vlachogianni T

    2013-11-01

    Full Text Available Thomais Vlachogianni,1 Konstantinos Fiotakis,1 Spyridon Loridas,1 Stamatis Perdicaris,2 Athanasios Valavanidis1 1Department of Chemistry, Free Radicals Research Group, 2Faculty of Pharmacy, Department of Pharmacognosy and Natural Product Chemistry, University of Athens, Athens, Greece Abstract: Engineered nanomaterials (ENMs are a diverse group of materials finding increasing use in manufacturing, computing, food, pharmaceuticals, and biomedicine due to their very small size and exceptional properties. Health and safety concerns for ENMs have forced regulatory agencies to consider preventive measures and regulations for workers’ health and safety protection. Respiratory system toxicity from inhalable ENMs is the most important concern to health specialists. In this review, we focus on similarities and differences between conventional microparticles (diameters in mm and µm, which have been previously studied, and nanoparticles (sizes between 1 and 100 nm in terms of size, composition, and mechanisms of action in biological systems. In past decades, respirable particulate matter (PM, asbestos fibers, crystalline silicate, and various amorphous dusts have been studied, and epidemiological evidence has shown how dangerous they are to human health, especially from exposure in working environments. Scientific evidence has shown that there is a close connection between respirable PM and pulmonary oxidative stress through the generation of reactive oxygen species (ROS and reactive nitrogen species (RNS. There is a close connection between oxidative stress in the cell and the elicitation of an inflammatory response via pro-inflammatory gene transcription. Inflammatory processes increase the risk for lung cancer. Studies in vitro and in vivo in the last decade have shown that engineered nanoparticles (ENPs at various doses can cause ROS generation, oxidative stress, and pro-inflammatory gene expression in the cell. It is assumed that ENPs have the

  11. A computer-aided audit system for respiratory therapy consult evaluations: description of a method and early results.

    Kester, Lucy; Stoller, James K

    2013-05-01

    Use of respiratory therapist (RT)-guided protocols enhances allocation of respiratory care. In the context that optimal protocol use requires a system for auditing respiratory care plans to assure adherence to protocols and expertise of the RTs generating the care plan, a live audit system has been in longstanding use in our Respiratory Therapy Consult Service. Growth in the number of RT positions and the need to audit more frequently has prompted development of a new, computer-aided audit system. The number and results of audits using the old and new systems were compared (for the periods May 30, 2009 through May 30, 2011 and January 1, 2012 through May 30, 2012, respectively). In contrast to the original, live system requiring a patient visit by the auditor, the new system involves completion of a respiratory therapy care plan using patient information in the electronic medical record, both by the RT generating the care plan and the auditor. Completing audits in the new system also uses an electronic respiratory therapy management system. The degrees of concordance between the audited RT's care plans and the "gold standard" care plans using the old and new audit systems were similar. Use of the new system was associated with an almost doubling of the rate of audits (ie, 11 per month vs 6.1 per month). The new, computer-aided audit system increased capacity to audit more RTs performing RT-guided consults while preserving accuracy as an audit tool. Ensuring that RTs adhere to the audit process remains the challenge for the new system, and is the rate-limiting step.

  12. Natural gas usage as a heat source for integrated SMR and thermochemical hydrogen production technologies

    Jaber, O.; Naterer, G.F.; Dincer, I.

    2010-01-01

    This paper investigates various usages of natural gas (NG) as an energy source for different hydrogen production technologies. A comparison is made between the different methods of hydrogen production, based on the total amount of natural gas needed to produce a specific quantity of hydrogen, carbon dioxide emissions per mole of hydrogen produced, water requirements per mole of hydrogen produced, and a cost sensitivity analysis that takes into account the fuel cost, carbon dioxide capture cost and a carbon tax. The methods examined are the copper-chlorine (Cu-Cl) thermochemical cycle, steam methane reforming (SMR) and a modified sulfur-iodine (S-I) thermochemical cycle. Also, an integrated Cu-Cl/SMR plant is examined to show the unique advantages of modifying existing SMR plants with new hydrogen production technology. The analysis shows that the thermochemical Cu-Cl cycle out-performs the other conventional methods with respect to fuel requirements, carbon dioxide emissions and total cost of production. (author)

  13. Time-of-flight small-angle-neutron-scattering data reduction and analysis at LANSCE (Los Alamos Neutron Scattering Center) with program SMR

    Hjelm, R.P. Jr.; Seegar, P.A.

    1989-01-01

    A user-friendly, integrated system, SMR, for the display, reduction and analysis of data from time-of-flight small-angle neutron diffractometers is described. Its purpose is to provide facilities for data display and assessment and to provide these facilities in near real time. This allows the results of each scattering measurement to be available almost immediately, and enables the experimenter to use the results of a measurement as a basis for other measurements in the same instrument allocation. 8 refs., 11 figs

  14. Functional Impairment of Mononuclear Phagocyte System by the Human Respiratory Syncytial Virus

    Karen Bohmwald

    2017-11-01

    Full Text Available The mononuclear phagocyte system (MPS comprises of monocytes, macrophages (MΦ, and dendritic cells (DCs. MPS is part of the first line of immune defense against a wide range of pathogens, including viruses, such as the human respiratory syncytial virus (hRSV. The hRSV is an enveloped virus that belongs to the Pneumoviridae family, Orthopneumovirus genus. This virus is the main etiological agent causing severe acute lower respiratory tract infection, especially in infants, children and the elderly. Human RSV can cause bronchiolitis and pneumonia and it has also been implicated in the development of recurrent wheezing and asthma. Monocytes, MΦ, and DCs significantly contribute to acute inflammation during hRSV-induced bronchiolitis and asthma exacerbation. Furthermore, these cells seem to be an important component for the association between hRSV and reactive airway disease. After hRSV infection, the first cells encountered by the virus are respiratory epithelial cells, alveolar macrophages (AMs, DCs, and monocytes in the airways. Because AMs constitute the predominant cell population at the alveolar space in healthy subjects, these cells work as major innate sentinels for the recognition of pathogens. Although adaptive immunity is crucial for viral clearance, AMs are required for the early immune response against hRSV, promoting viral clearance and controlling immunopathology. Furthermore, exposure to hRSV may affect the phagocytic and microbicidal capacity of monocytes and MΦs against other infectious agents. Finally, different studies have addressed the roles of different DC subsets during infection by hRSV. In this review article, we discuss the role of the lung MPS during hRSV infection and their involvement in the development of bronchiolitis.

  15. Systems for the management of respiratory disease in primary care - an international series: Australia.

    Glasgow, Nicholas

    2008-03-01

    Australia has a complex health system with policy and funding responsibilities divided across federal and state/territory boundaries and service provision split between public and private providers. General practice is largely funded through the federal government. Other primary health care services are provided by state/territory public entities and private allied health practitioners. Indigenous health services are specifically funded by the federal government through a series of Aboriginal Community Controlled Organisations. NATIONAL POLICY AND MODELS: The dominant primary health care model is federally-funded private "small business" general practices. Medicare reimbursement items have incrementally changed over the last decade to include increasing support for chronic disease care with both generic and disease specific items as incentives. Asthma has received a large amount of national policy attention. Other respiratory diseases have not had similar policy emphasis. Australia has a high prevalence of asthma. Respiratory-related encounters in general practice, including acute and chronic respiratory illness and influenza immunisations, account for 20.6% of general practice activity. Lung cancer is a rare disease in general practice. Tuberculosis is uncommon and most often found in people born outside of Australia. Aboriginal and Torres Strait Islanders have higher rates of asthma, smoking and tuberculosis. Access to care is positively influenced by substantial public funding underpinning both the private and public sectors through Medicare. Access to general practice care is negatively influenced by workforce shortages, the ongoing demands of acute care, and the incremental way in which system redesign is occurring in general practice. Most general practice operates from privately-owned rooms. The Australian Government requires general practice facilities to be accredited against certain standards in order for the practice to receive income from a number of

  16. Financial feasibility analysis on small medium reactor nuclear power plant (SMR NPP) project in Indonesia under uncertainty

    Nuryanti; Suparman; Mochamad Nasrullah; Elok Satiti Amitayani; Wiku Lulus Widodo

    2015-01-01

    NPP SMR is one alternative to overcome the Outside Java Bali region's dependence on diesel power plant. One crucial issue in the NPP project (including SMR) would be financing, associated with the capital-intensive nature of the project. In addition, the SMR NPP project also be vulnerable in occurrence of some uncertainties. Therefore, this study aimed to analyze the financial feasibility of SMR NPP project by accommodating the possibility of the uncertainties. The methodology used is probabilistic analysis which was performed by Monte Carlo technique. This technique simulates the relationship between the uncertainty variables with financial feasibility indicators. The results showed that in probabilistic approach, SMR NPP project is considered feasible on the 'most probable value' of electricity selling price of 15 cents/kWh, indicated by positive average value of NPV (US$ 135,324,004) and the average value of both of IRRs are bigger than MARR (IRR project = 10.65 %, IRR Equity = 14.29 %, while MARR = 10 %). The probability of rejection of the SMR project was about 20 %. The three main variables that are most influential in the project were: selling price of electricity, investment cost and inflation rate. (author)

  17. Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system

    Li, X. Allen; Stepaniak, Christopher; Gore, Elizabeth

    2006-01-01

    This work introduces a gating technique that uses 4DCT to determine gating parameters and to plan gated treatment, and employs a Siemens linear accelerator to deliver the gated treatment. Because of technology incompatibility, the 4DCT scanner (LightSpeed, GE) and the Siemens accelerator require two different motion-monitoring systems. The motion monitoring system (AZ-773V, Anzai Med.) used for the gated delivery utilizes a pressure sensor to detect the external respiratory motion (pressure change) in real time. Another system (RPM, Varian) used for the 4DCT scanner (LightSpeed, GE) is based on an infrared camera to detect motion of external markers. These two motion monitoring systems (RPM and Anzai systems) were found to correlate well with each other. The depth doses and profile measured for gated delivery (with a duty cycle of 25% or 50%) were found to agree within 1.0% with those measured for ungated delivery, indicating that gating did not significantly alter beam characteristics. The measurement verified also that the MU linearity and beam output remained unchanged (within 0.3%). A practical method of using 4DCT to plan a gated treatment was developed. The duty cycle for either phase or amplitude gating can be determined based on 4DCT with consideration of set-up error and delivery efficiency. The close-loop measurement involving the entire gating process (imaging, planning, and delivery) showed that the measured isodose distributions agreed with those intended, validating the accuracy and reliability of the gating technique. Based these observations, we conclude that the gating technique introduced in this work, integrating Siemens linear accelerator and Anzai pressure sensor device with GE/Varian RPM 4DCT, is reliable and effective, and it can be used clinically to account for respiratory motion during radiation therapy

  18. Evaluation of irradiation position in respiratory-gated radiotherapy using a phantom system simulating patient respiration

    Oyama, Masaya; Ueda, Takashi; Kitoh, Satoshi; Tanaka, Takashi; Goka, Tomonori; Ogino, Takashi

    2006-01-01

    Respiratory-gated (RG) radiotherapy is useful for minimizing the irradiated volume of normal tissues resulting from the shifting of internal structures caused by respiratory movement. The present study was conducted to evaluate the treatment field in RG radiotherapy using a phantom system simulating patient respiration. A phantom system consisting of a 3-cm ball-shaped dummy tumor and film placed in a cork lung phantom was used (THK Co., Ltd.). RG radiotherapy was employed in the expiratory phase. The phantom movement distance was set to 2 cm, and the gating signals from a respiratory-gating system (AZ-733V, Anzai Medical) were varied. The settings used for irradiation were an X-ray energy of 6 MV (PRIMUS, Toshiba Medical Systems), treatment field of 5 cm x 7 cm, and X-ray dose of 100 MU. Images were acquired using an electric portal-imaging device (EPID, OPTIVUE 500), and the X-ray dose distribution was measured by the film method. In images acquired using the EPID, the tumor margins became less clear when the gating signals were increased, and the ITVs were determined to be 3.6 cm, 3.7 cm, 4.2 cm, and 5.1 cm at gating rates of 10%, 25%, 50%, and no gate, respectively. With regard to the X-ray dose distribution measured by the film method, the dose profile in the cephalocaudal direction was shifted toward the expiratory phase, and the degree of shift became greater when the gating signals were increased. In addition, the optimal treatment fields in the cephalocaudal direction were determined to be 5.2 cm, 5.2 cm, 5.6 cm, and 7.0 cm at gating rates of 10%, 25%, 50%, and no gating, respectively. Although RG radiotherapy is useful for improving the accuracy of radiotherapy, the characteristics of the RG radiotherapy technique and the radiotherapy system must be clearly understood when this method is to be employed in clinical practice. Image-guided radiotherapy (IGRT) is now assuming a central role in radiotherapy, and properly identifying internal margins is an

  19. Systems for the management of respiratory disease in primary care--an international series: Pakistan.

    Yusuf, Mohammed Osman

    2009-03-01

    Pakistan has a population exceeding 160 million. Communicable diseases remain the most important health problem in Pakistan, with non-communicable diseases and injuries comprising a quarter of all deaths. The government provides a multi-tiered healthcare system, from the Basic Health Unit at the village level, ranging up to the tertiary care teaching hospitals in the larger cities. These facilities are accessible to all, and are usually free or highly subsidised. Patients have the choice to see a private or government GP, a specialist, or an alternative medicine healer. The current National Health Policy focusses mainly on prevention of communicable diseases, as well as improving primary and secondary health care services. Only 6% of 13 to 14 year olds are medically diagnosed as having asthma, and more than half report symptoms of rhinitis. The prevalence of chronic bronchitis in patients over 65 is 14% and 6% in rural females and males, respectively, and 9% (with no sex difference) in urban areas. The higher rates of chronic bronchitis observed in females in rural areas may be attributed to high levels of indoor air pollution due to cooking over smoking fires. It is estimated that 36% of adult males, and 9% of females, smoke, and the cigarette consumption per person per year in Pakistan is among the highest in South Asia. Pakistan is ranked 7th among the 22 highest tuberculosis disease burden countries in the world. In 2006 the number of all TB cases was 76,668 compared to 97,245 in 2004. It is estimated that 70-80,000 people are infected with HIV, but only 3,000 AIDS cases have been reported so far. The incidence of acute respiratory infections in children varies, and is a common cause of morbidity. In adults, it is estimated that pneumonia may affect as many as 2.8 million Pakistanis. Patients usually can access their local GPs or alternative medical practitioners with relative ease. In villages in remote areas, access to government-run health care facilities

  20. Respiratory alkalosis

    Alkalosis - respiratory ... leads to shortness of breath can also cause respiratory alkalosis (such as pulmonary embolism and asthma). ... Treatment is aimed at the condition that causes respiratory alkalosis. Breathing into a paper bag -- or using ...

  1. Detecting regional lung properties using audio transfer functions of the respiratory system.

    Mulligan, K; Adler, A; Goubran, R

    2009-01-01

    In this study, a novel instrument has been developed for measuring changes in the distribution of lung fluid the respiratory system. The instrument consists of a speaker that inputs a 0-4kHz White Gaussian Noise (WGN) signal into a patient's mouth and an array of 4 electronic stethoscopes, linked via a fully adjustable harness, used to recover signals on the chest surface. The software system for processing the data utilizes the principles of adaptive filtering in order to obtain a transfer function that represents the input-output relationship for the signal as the volume of fluid in the lungs is varied. A chest phantom model was constructed to simulate the behavior of fluid related diseases within the lungs through the injection of varying volumes of water. Tests from the phantom model were compared to healthy subjects. Results show the instrument can obtain similar transfer functions and sound propagation delays between both human and phantom chests.

  2. Mathematical modeling and validation in physiology applications to the cardiovascular and respiratory systems

    Bachar, Mostafa; Kappel, Franz

    2013-01-01

    This volume synthesizes theoretical and practical aspects of both the mathematical and life science viewpoints needed for modeling of the cardiovascular-respiratory system specifically and physiological systems generally.  Theoretical points include model design, model complexity and validation in the light of available data, as well as control theory approaches to feedback delay and Kalman filter applications to parameter identification. State of the art approaches using parameter sensitivity are discussed for enhancing model identifiability through joint analysis of model structure and data. Practical examples illustrate model development at various levels of complexity based on given physiological information. The sensitivity-based approaches for examining model identifiability are illustrated by means of specific modeling  examples. The themes presented address the current problem of patient-specific model adaptation in the clinical setting, where data is typically limited.

  3. Buying Time—The Immune System Determinants of the Incubation Period to Respiratory Viruses

    Thomas M. Moran

    2010-11-01

    Full Text Available Respiratory viruses cause disease in humans characterized by an abrupt onset of symptoms. Studies in humans and animal models have shown that symptoms are not immediate and appear days or even weeks after infection. Since the initial symptoms are a manifestation of virus recognition by elements of the innate immune response, early virus replication must go largely undetected. The interval between infection and the emergence of symptoms is called the incubation period and is widely used as a clinical score. While incubation periods have been described for many virus infections the underlying mechanism for this asymptomatic phase has not been comprehensively documented. Here we review studies of the interaction between human pathogenic respiratory RNA viruses and the host with a particular emphasis on the mechanisms used by viruses to inhibit immunity. We discuss the concept of the “stealth phase”, defined as the time between infection and the earliest detectable inflammatory response. We propose that the “stealth phase” phenomenon is primarily responsible for the suppression of symptoms during the incubation period and results from viral antagonism that inhibits major pathways of the innate immune system allowing an extended time of unhindered virus replication.

  4. Cytotoxicity of carbon nanohorns in different human cells of the respiratory system.

    Schramm, Franziska; Lange, Martina; Hoppmann, Pia; Heutelbeck, Astrid

    2016-01-01

    One of the new synthetic carbon-based nanomaterials is carbon nanohorns (CNH). A potential risk for employees of production processes is an unintentional intake of these nanomaterials via inhalation. Once taken up, nanoparticles might interact with cells of different tissues as well as with intercellular substances. These interactions may have far-reaching consequences for human health. Currently, many gaps in available information on the CNH toxicological profile remain. The aim of this study was to determine the cytotoxicity of CNH particles on human epithelial cells of the respiratory system with special consideration given to different particle sizes. In all cell lines, cell viability was reduced after 24 h of exposure up to 60% and metabolic activity as evidenced by mitochondrial activity was lowered to 9% at a concentration of 1 g/L. The three respiratory cell lines differed in their sensitivity. The most robust cells were the bronchial epithelial cells. Further, particle size fractions induced different adverse effect strength, whereby no correlation between particle size fraction and toxicity was found. These findings demonstrate the need for further information regarding the behavior and effect strength of nanomaterial. To avoid the production of new harmful materials, a more comprehensive integration of results from toxicity studies in the development processes of engineered nanomaterials is recommended not only from an occupational viewpoint but also from an environmental perspective.

  5. Inhaled Pollutants: The Molecular Scene behind Respiratory and Systemic Diseases Associated with Ultrafine Particulate Matter

    Hussein Traboulsi

    2017-01-01

    Full Text Available Air pollution of anthropogenic origin is largely from the combustion of biomass (e.g., wood, fossil fuels (e.g., cars and trucks, incinerators, landfills, agricultural activities and tobacco smoke. Air pollution is a complex mixture that varies in space and time, and contains hundreds of compounds including volatile organic compounds (e.g., benzene, metals, sulphur and nitrogen oxides, ozone and particulate matter (PM. PM0.1 (ultrafine particles (UFP, those particles with a diameter less than 100 nm (includes nanoparticles (NP are considered especially dangerous to human health and may contribute significantly to the development of numerous respiratory and cardiovascular diseases such as chronic obstructive pulmonary disease (COPD and atherosclerosis. Some of the pathogenic mechanisms through which PM0.1 may contribute to chronic disease is their ability to induce inflammation, oxidative stress and cell death by molecular mechanisms that include transcription factors such as nuclear factor κB (NF-κB and nuclear factor (erythroid-derived 2-like 2 (Nrf2. Epigenetic mechanisms including non-coding RNA (ncRNA may also contribute towards the development of chronic disease associated with exposure to PM0.1. This paper highlights emerging molecular concepts associated with inhalational exposure to PM0.1 and their ability to contribute to chronic respiratory and systemic disease.

  6. Amyloidosis involving the respiratory system: 5-year′s experience of a multi-disciplinary group′s activity

    Raffaele Scala

    2015-01-01

    Full Text Available Amyloidosis may involve the respiratory system with different clinical-radiological-functional patterns which are not always easy to be recognized. A good level of knowledge of the disease, an active integration of the pulmonologist within a multidisciplinary setting and a high level of clinical suspicion are necessary for an early diagnosis of respiratory amyloidosis. The aim of this retrospective study was to evaluate the number and the patterns of amyloidosis involving the respiratory system. We searched the cases of amyloidosis among patients attending the multidisciplinary rare and diffuse lung disease outpatients′ clinic of Pulmonology Unit of the Hospital of Arezzo from 2007 to 2012. Among the 298 patients evaluated during the study period, we identified three cases of amyloidosis with involvement of the respiratory system, associated or not with other extra-thoracic localizations, whose diagnosis was histo-pathologically confirmed after the pulmonologist, the radiologist, and the pathologist evaluation. Our experience of a multidisciplinary team confirms that intra-thoracic amyloidosis is an uncommon disorder, representing 1.0% of the cases of rare and diffuse lung diseases referred to our center. The diagnosis of the disease is not always easy and quick as the amyloidosis may involve different parts of the respiratory system (airways, pleura, parenchyma. It is therefore recommended to remind this orphan disease in the differential diagnosis of the wide clinical scenarios the pulmonologist may intercept in clinical practice.

  7. SPECIFIC DISORDERS OF THE RESPIRATORY SYSTEM IN CYSTIC FIBROSIS. CLINICAL EFFICACY OF THERAPY WITH DORNASE ALFA IN CHILDREN

    T.V. Simanova

    2010-01-01

    Full Text Available The article is devoted to specific disorders of the respiratory system in cystic fibrosis. 64 patients with cystic fibrosis (CF aged 2 months to 32 years and residing in the Udmurtian Republic were studied. Epidemiological and genetic specifics of this disease in the mentioned region of the RF were examined. Clinical, X-ray, functional and microbiological studies of the CF patients’ respiratory system were conducted. It was found that genotype delF508 and chronic infection Pseudomonas aeruginosa, Staphylococcus aureus cause severe structural changes to the bronchopulmonary system more often. The obtained data suggest the advisability of identifying the groups of CF patients at the highest risk of severe respiratory system disorders in order to optimise therapeutic efforts. The article provides indicators of clinical efficacy of a dornase alfa therapy in CF children.Key words: cystic fibrosis, genotype, delF508 mutation, respiratory organs, pseudomonas aeruginosa infection, staphylococcal infection, respiratory function, mucolytic function, dornase alfa. (Pediatric Pharmacology. – 2010; 7(6:44-48

  8. Estimate of the real-time respiratory simulation system in cyberknife image-guided radiosurgery

    Min, Chul Kee; Chung, Weon Kuu; Lee, Suk

    2010-01-01

    The purpose of this study was to evaluate the target accuracy according to the movement with respiration of an actual patient in a quantitative way by developing a real-time respiratory simulation system (RRSS), including a patient customized 3D moving phantom. The real-time respiratory simulation system (RRSS) consists of two robots in order to implement both the movement of body surfaces and the movement of internal organs caused by respiration. The quantitative evaluation for the 3D movement of the RRSS was performed using a real-time laser displacement sensor for each axis. The average difference in the static movement of the RRSS was about 0.01 ∼ 0.06 mm. Also, in the evaluation of the dynamic movement by producing a formalized sine wave with the phase of four seconds per cycle, the difference between the measured and the calculated values for each cycle length in the robot that was in charge of body surfaces and the robot that was in charge of the movement of internal tumors showed 0.10 ∼ 0.55 seconds, and the correlation coefficients between the calculated and the measured values were 0.998 ∼ 0.999. The differences between the maximum and the minimum amplitudes were 0.01 ∼ 0.06 mm, and the reproducibility was within ±0.5 mm. In the case of the application and non-application of respiration, the target errors were -0.05 ∼ 1.05 mm and -0.13 ∼ 0.74 mm, respectively, and the entire target errors were 1.30 mm and 0.79 mm, respectively. Based on the accuracy in the RRSS system, various respiration patterns of patients can be reproduced in real-time. Also, this system can be used as an optimal tool for applying patient customized accuracy management in image-guided radiosurgery.

  9. Estimate of the real-time respiratory simulation system in cyberknife image-guided radiosurgery

    Min, Chul Kee [Konyang Univ. Hospital, Daejeon (Korea, Republic of); Kyonggi University, Seoul (Korea, Republic of); Chung, Weon Kuu [Konyang Univ. Hospital, Daejeon (Korea, Republic of); Lee, Suk [Korea University, Seoul (Korea, Republic of); and others

    2010-01-15

    The purpose of this study was to evaluate the target accuracy according to the movement with respiration of an actual patient in a quantitative way by developing a real-time respiratory simulation system (RRSS), including a patient customized 3D moving phantom. The real-time respiratory simulation system (RRSS) consists of two robots in order to implement both the movement of body surfaces and the movement of internal organs caused by respiration. The quantitative evaluation for the 3D movement of the RRSS was performed using a real-time laser displacement sensor for each axis. The average difference in the static movement of the RRSS was about 0.01 {approx} 0.06 mm. Also, in the evaluation of the dynamic movement by producing a formalized sine wave with the phase of four seconds per cycle, the difference between the measured and the calculated values for each cycle length in the robot that was in charge of body surfaces and the robot that was in charge of the movement of internal tumors showed 0.10 {approx} 0.55 seconds, and the correlation coefficients between the calculated and the measured values were 0.998 {approx} 0.999. The differences between the maximum and the minimum amplitudes were 0.01 {approx} 0.06 mm, and the reproducibility was within {+-}0.5 mm. In the case of the application and non-application of respiration, the target errors were -0.05 {approx} 1.05 mm and -0.13 {approx} 0.74 mm, respectively, and the entire target errors were 1.30 mm and 0.79 mm, respectively. Based on the accuracy in the RRSS system, various respiration patterns of patients can be reproduced in real-time. Also, this system can be used as an optimal tool for applying patient customized accuracy management in image-guided radiosurgery.

  10. LEADIR-PS: providing unprecedented SMR safety and economics

    Hart, R.S., E-mail: N2i2@xplornet.ca [Northern Nuclear Industries Incorporated, Cambridge, ON (Canada)

    2015-07-01

    Northern Nuclear Industries Incorporated (N{sup 2} I{sup 2}) is developing Small Modular Reactors (SMRs) called LEADIR-PS, an acronym for LEAD-cooled Integral Reactor-Passively Safe. LEADIR-PS integrates proven technologies including TRISO fuel, Pebble Bed core and graphite moderator, with molten lead coolant in an integral pool type reactor configuration to achieve unprecedented safety and economics. Plants under development are LEADIR-PS30, producing 30 MWth, LEADIR-PS100 producing 100 MWth and LEADIR-PS300 producing 300 MWth that are focused on serving the energy demands of areas with a small electrical grid and/or process heat applications. A plant consisting of six LEADIR-PS300 reactor modules serving a common turbine-generator, called the LEADIR-PS Six-Pack, is focused on serving areas with higher energy demands and a robust electricity grid. The Gen{sup +} I LEADIR-PS plants are inherently/passively safe. There is no potential for a Loss Of Coolant Accident, a reactivity transient without shutdown, a loss of heat sink, or hydrogen generation. No active systems or operator actions are required to assure safety. The unprecedented safety of LEADIR-PS reactors avoids large exclusion radius and demanding evacuation plan requirements. LEADIR-PS, with steam conditions of 370 {sup o}C and 12 MPa can serve over 85% of the world's non-transportation process heat demands. In Canada, the electricity and process heat demands, ranging from those of remote communities and the oil sands to densely populated areas can be served by LEADIR-PS. (author)

  11. Experimental verification of a two-dimensional respiratory motion compensation system with ultrasound tracking technique in radiation therapy.

    Ting, Lai-Lei; Chuang, Ho-Chiao; Liao, Ai-Ho; Kuo, Chia-Chun; Yu, Hsiao-Wei; Zhou, Yi-Liang; Tien, Der-Chi; Jeng, Shiu-Chen; Chiou, Jeng-Fong

    2018-05-01

    This study proposed respiratory motion compensation system (RMCS) combined with an ultrasound image tracking algorithm (UITA) to compensate for respiration-induced tumor motion during radiotherapy, and to address the problem of inaccurate radiation dose delivery caused by respiratory movement. This study used an ultrasound imaging system to monitor respiratory movements combined with the proposed UITA and RMCS for tracking and compensation of the respiratory motion. Respiratory motion compensation was performed using prerecorded human respiratory motion signals and also sinusoidal signals. A linear accelerator was used to deliver radiation doses to GAFchromic EBT3 dosimetry film, and the conformity index (CI), root-mean-square error, compensation rate (CR), and planning target volume (PTV) were used to evaluate the tracking and compensation performance of the proposed system. Human respiratory pattern signals were captured using the UITA and compensated by the RMCS, which yielded CR values of 34-78%. In addition, the maximum coronal area of the PTV ranged from 85.53 mm 2 to 351.11 mm 2 (uncompensated), which reduced to from 17.72 mm 2 to 66.17 mm 2 after compensation, with an area reduction ratio of up to 90%. In real-time monitoring of the respiration compensation state, the CI values for 85% and 90% isodose areas increased to 0.7 and 0.68, respectively. The proposed UITA and RMCS can reduce the movement of the tracked target relative to the LINAC in radiation therapy, thereby reducing the required size of the PTV margin and increasing the effect of the radiation dose received by the treatment target. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Efficacy of a Respiratory Training System on the Regularity of Breathing

    Shin, Eun Hyuk; Park, Hee Chul; Han, Young Yih; Ju, Sang Gyu; Shin, Jung Suk; Ahn, Yong Chan

    2008-01-01

    In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal

  13. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    Parsaei H.

    2017-03-01

    Full Text Available Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan.

  14. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    Parsaei, H.; Vakily, A.; Shafiei, A.M.

    2017-01-01

    Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan. PMID:28451580

  15. Work Domain Analysis of a Predecessor Sodium-cooled Reactor as Baseline for AdvSMR Operational Concepts

    Ronald Farris; David Gertman; Jacques Hugo

    2014-03-01

    This report presents the results of the Work Domain Analysis for the Experimental Breeder Reactor (EBR-II). This is part of the phase of the research designed to incorporate Cognitive Work Analysis in the development of a framework for the formalization of an Operational Concept (OpsCon) for Advanced Small Modular Reactors (AdvSMRs). For a new AdvSMR design, information obtained through Cognitive Work Analysis, combined with human performance criteria, can and should be used in during the operational phase of a plant to assess the crew performance aspects associated with identified AdvSMR operational concepts. The main objective of this phase was to develop an analytical and descriptive framework that will help systems and human factors engineers to understand the design and operational requirements of the emerging generation of small, advanced, multi-modular reactors. Using EBR-II as a predecessor to emerging sodium-cooled reactor designs required the application of a method suitable to the structured and systematic analysis of the plant to assist in identifying key features of the work associated with it and to clarify the operational and other constraints. The analysis included the identification and description of operating scenarios that were considered characteristic of this type of nuclear power plant. This is an invaluable aspect of Operational Concept development since it typically reveals aspects of future plant configurations that will have an impact on operations. These include, for example, the effect of core design, different coolants, reactor-to-power conversion unit ratios, modular plant layout, modular versus central control rooms, plant siting, and many more. Multi-modular plants in particular are expected to have a significant impact on overall OpsCon in general, and human performance in particular. To support unconventional modes of operation, the modern control room of a multi-module plant would typically require advanced HSIs that would

  16. Comparison of visual biofeedback system with a guiding waveform and abdomen-chest motion self-control system for respiratory motion management

    Nakajima, Yujiro; Kadoya, Noriyuki; Kanai, Takayuki; Ito, Kengo; Sato, Kiyokazu; Dobashi, Suguru; Yamamoto, Takaya; Ishikawa, Yojiro; Matsushita, Haruo; Takeda, Ken; Jingu, Keiichi

    2016-01-01

    Irregular breathing can influence the outcome of 4D computed tomography imaging and cause artifacts. Visual biofeedback systems associated with a patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches) (representing simpler visual coaching techniques without a guiding waveform) are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching in reducing respiratory irregularities by comparing two respiratory management systems. We collected data from 11 healthy volunteers. Bar and wave models were used as visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. All coaching techniques improved respiratory variation, compared with free-breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86 and 0.98 ± 0.47 mm for free-breathing, Abches, bar model and wave model, respectively. Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18 and 0.17 ± 0.05 s for free-breathing, Abches, bar model and wave model, respectively. The average reduction in displacement and period RMSE compared with the wave model were 27% and 47%, respectively. For variation in both displacement and period, wave model was superior to the other techniques. Our results showed that visual biofeedback combined with a wave model could potentially provide clinical benefits in respiratory management, although all techniques were able to reduce respiratory irregularities

  17. Experiment for ambulatory inhalation rehabilitation of occupational dust-radiation injuries of the respiratory system

    Ivanov, Z.; Nikolova, M.E.; Todorov, A.; Kuteva, E.

    1984-01-01

    An experiment was carried out for ambulatory inhalation rehabilitation on a group of 172 subjects with pronounced injuries of the respiratory system. Parallely with them was a rehabilitated group of 8 pensioners. Because of the specific nature of the production etiopathogenetic complex including inhalation introduced radioactive and stable aerosols and their uninterrupted action during rehabilitation, the experiment conducted is of special importance for the perspective elaboration and implementation of health measures in a numerous contingent of workers in industrial important branches without discontinuing work. A positive effect was obtained in 54,2% of the treated non-smokers. No improvement was found of the objective ventilation indices of respiration in smokers and pensioners. As far as physical and anamnestic indices are concerned, such as rales, cough, dyspnea, pains in the chest etc., there was impovement in all treated subjects. Finally, some conclusions are drawn about the future trends of inhalation prophylaxis in the respective branches of production

  18. A study on the relationship between trace elements and respiratory system diseases

    Hou Xiaolin; Wu Lanlan; Yuan Ling; Huang Liyun; Jia Zhanxiang; Chen Yang

    1995-01-01

    19 elements (Ca, Mg, Fe, Se, Cu, Zn, etc.) in hair of 65 patients with chronic bronchitis, pulmonary emphysema and corpulmonale and 65 healthy persons were determined with instrumental neutron activation analysis. It was shown that the contents of Ca and Mg are lower while the contents of Fe, As and Co higher for the patients. For the patients with chronic bronchitis in attack period the contents of Ca and Mg are lower and the content of Fe higher than those in relaxed period. A highly positive relation between Ca and Mg contents was also found. In addition, inorganic elements in 'Kechuandeping' capsule, a prepared traditional Chinese medicine to treat chronic bronchitis, were determined, and the contents of Ca, Mg, Sr, etc. were found higher than the corresponding average values for 120 kinds of traditional Chinese medicines, indicating a possible shortage of Ca, Mg, etc. for the patients with respiratory-system diseased

  19. Systemic signature of the lung response to respiratory syncytial virus infection.

    Jeroen L A Pennings

    Full Text Available Respiratory Syncytial Virus is a frequent cause of severe bronchiolitis in children. To improve our understanding of systemic host responses to RSV, we compared BALB/c mouse gene expression responses at day 1, 2, and 5 during primary RSV infection in lung, bronchial lymph nodes, and blood. We identified a set of 53 interferon-associated and innate immunity genes that give correlated responses in all three murine tissues. Additionally, we identified blood gene signatures that are indicative of acute infection, secondary immune response, and vaccine-enhanced disease, respectively. Eosinophil-associated ribonucleases were characteristic for the vaccine-enhanced disease blood signature. These results indicate that it may be possible to distinguish protective and unfavorable patient lung responses via blood diagnostics.

  20. [Characteristics of the sympathoadrenal system response to psychoemotional stress under hypoxic conditions in aged people with physiological and accelerated aging of the respiratory system].

    Asanov, E O; Os'mak, Ie D; Kuz'mins'ka, L A

    2013-01-01

    The peculiarities of the response of the sympathoadrenal system to psychoemotional and hypoxic stress in healthy young people and in aged people with physiological and accelerated aging of respiratory system were studied. It was shown that in aging a more pronounced response of the sympathoadrenal system to psychoemotional stress. At the same time, elderly people with different types of aging of the respiratory system did not demonstrate a difference in the response of the sympathoadrenal system to psychoemotional stress. Unlike in young people, in aged people, combination of psychoemotional and hypoxic stresses resulted in further activation of the sympathoadrenal system. The reaction of the sympathoadrenal system was more expressed in elderly people with accelerated ageing of the respiratory system.

  1. Evaluation of the educational value of YouTube videos about physical examination of the cardiovascular and respiratory systems.

    Azer, Samy A; Algrain, Hala A; AlKhelaif, Rana A; AlEshaiwi, Sarah M

    2013-11-13

    A number of studies have evaluated the educational contents of videos on YouTube. However, little analysis has been done on videos about physical examination. This study aimed to analyze YouTube videos about physical examination of the cardiovascular and respiratory systems. It was hypothesized that the educational standards of videos on YouTube would vary significantly. During the period from November 2, 2011 to December 2, 2011, YouTube was searched by three assessors for videos covering the clinical examination of the cardiovascular and respiratory systems. For each video, the following information was collected: title, authors, duration, number of viewers, and total number of days on YouTube. Using criteria comprising content, technical authority, and pedagogy parameters, videos were rated independently by three assessors and grouped into educationally useful and non-useful videos. A total of 1920 videos were screened. Only relevant videos covering the examination of adults in the English language were identified (n=56). Of these, 20 were found to be relevant to cardiovascular examinations and 36 to respiratory examinations. Further analysis revealed that 9 provided useful information on cardiovascular examinations and 7 on respiratory examinations: scoring mean 14.9 (SD 0.33) and mean 15.0 (SD 0.00), respectively. The other videos, 11 covering cardiovascular and 29 on respiratory examinations, were not useful educationally, scoring mean 11.1 (SD 1.08) and mean 11.2 (SD 1.29), respectively. The differences between these two categories were significant (P.86. A small number of videos about physical examination of the cardiovascular and respiratory systems were identified as educationally useful; these videos can be used by medical students for independent learning and by clinical teachers as learning resources. The scoring system utilized by this study is simple, easy to apply, and could be used by other researchers on similar topics.

  2. How UK is preparing for major push towards world's first SMR

    Dalton, David [NucNet, Bruessel (Belgium)

    2017-01-15

    The UK Department of Business, Energy and Industrial Strategy is finalising a roadmap for the development of SMRs in the UK in parallel with the first phase of the competition. The roadmap will be published early in 2017, although whether it will be affected by the change in personnel at the top of government following the June 2016 vote for Brexit remains to be seen. The UK seems to be taking a lead in the development of SMRs. In its 2015 autumn budget statement, the government announced it would invest pound 250 m in an ''ambitious nuclear research and development programme'', including in the SMR competition.

  3. Naringenin degradation by the endophytic diazotroph Herbaspirillum seropedicae SmR1.

    Marin, A M; Souza, E M; Pedrosa, F O; Souza, L M; Sassaki, G L; Baura, V A; Yates, M G; Wassem, R; Monteiro, R A

    2013-01-01

    Several bacteria are able to degrade flavonoids either to use them as carbon sources or as a detoxification mechanism. Degradation pathways have been proposed for several bacteria, but the genes responsible are not known. We identified in the genome of the endophyte Herbaspirillum seropedicae SmR1 an operon potentially associated with the degradation of aromatic compounds. We show that this operon is involved in naringenin degradation and that its expression is induced by naringenin and chrysin, two closely related flavonoids. Mutation of fdeA, the first gene of the operon, and fdeR, its transcriptional activator, abolished the ability of H. seropedicae to degrade naringenin.

  4. Development of a Technical Basis and Guidance for Advanced SMR Function Allocation

    Jacques Hugo; David Gertman; Jeffrey Joe; Ronal Farris; April Whaley; Heather Medema

    2013-09-01

    This report presents the results from three key activities for FY13 that influence the definition of new concepts of operations for advanced Small Modular Reactors (AdvSMR: a) the development of a framework for the analysis of the functional environmental, and structural attributes, b) the effect that new technologies and operational concepts would have on the way functions are allocated to humans or machines or combinations of the two, and c) the relationship between new concepts of operations, new function allocations, and human performance requirements.

  5. Enterovirus serotypes in patients with central nervous system and respiratory infections in Viet Nam 1997-2010.

    B'Krong, Nguyen Thi Thuy Chinh; Minh, Ngo Ngoc Quang; Qui, Phan Tu; Chau, Tran Thi Hong; Nghia, Ho Dang Trung; Do, Lien Anh Ha; Nhung, Nguyen Ngoc; Van Vinh Chau, Nguyen; Thwaites, Guy; Van Tan, Le; van Doorn, H Rogier; Thanh, Tran Tan

    2018-04-12

    Enteroviruses are the most common causative agents of human illness. Enteroviruses have been associated with regional and global epidemics, recently, including with severe disease (Enterovirus A71 and D68), and are of interest as emerging viruses. Here, we typed Enterovirus A-D (EV) from central nervous system (CNS) and respiratory infections in Viet Nam. Data and specimens from prospective observational clinical studies conducted between 1997 and 2010 were used. Species and serotypes were determined using type-specific RT-PCR and viral protein 1 or 4 (VP1, VP4) sequencing. Samples from patients with CNS infection (51 children - 10 CSF and 41 respiratory/rectal swabs) and 28 adults (28 CSF) and respiratory infection (124 children - 124 respiratory swabs) were analysed. Twenty-six different serotypes of the four Enterovirus species (A-D) were identified, including EV-A71 and EV-D68. Enterovirus B was associated with viral meningitis in children and adults. Hand, foot and mouth disease associated Enteroviruses A (EV-A71 and Coxsackievirus [CV] A10) were detected in children with encephalitis. Diverse serotypes of all four Enterovirus species were found in respiratory samples, including 2 polio-vaccine viruses, but also 8 CV-A24 and 8 EV-D68. With the exception of EV-D68, the relevance of these viruses in respiratory infection remains unknown. We describe the diverse spectrum of enteroviruses from patients with CNS and respiratory infections in Viet Nam between 1997 and 2010. These data confirm the global circulation of Enterovirus genera and their associations and are important for clinical diagnostics, patient management, and outbreak response.

  6. New Combined Scoring System for Predicting Respiratory Failure in Iraqi Patients with Guillain-Barré Syndrome

    Zaki Noah Hasan

    2010-09-01

    Full Text Available The Guillain-Barré syndrome (GBS is an acute post-infective autoimmune polyradiculoneuropathy, it is the commonest peripheral neuropathy causing respiratory failure. The aim of the study is to use the New Combined Scoring System in anticipating respiratory failure in order to perform elective measures without waiting for emergency situations to occur.
    Patients and methods: Fifty patients with GBS were studied. Eight clinical parameters (including progression of patients to maximum weakness, respiratory rate/minute, breath holding
    count (the number of digits the patient can count in holding his breath, presence of facial muscle weakness (unilateral or bilateral, presence of weakness of the bulbar muscle, weakness of the neck flexor muscle, and limbs weakness were assessed for each patient and a certain score was given to
    each parameter, a designed combined score being constructed by taking into consideration all the above mentioned clinical parameters. Results and discussion: Fifteen patients (30% that were enrolled in our study developed respiratory failure. There was a highly significant statistical association between the development of respiratory failure and the lower grades of (bulbar muscle weakness score, breath holding count scores, neck muscle weakness score, lower limbs and upper limbs weakness score , respiratory rate score and the total sum score above 16 out of 30 (p-value=0.000 . No significant statistical difference was found regarding the progression to maximum weakness (p-value=0.675 and facial muscle weakness (p-value=0.482.
    Conclusion: The patients who obtained a combined score (above 16’30 are at great risk of having respiratory failure.

  7. Development of a robust and cost-effective 3D respiratory motion monitoring system using the kinect device: Accuracy comparison with the conventional stereovision navigation system.

    Bae, Myungsoo; Lee, Sangmin; Kim, Namkug

    2018-07-01

    To develop and validate a robust and cost-effective 3D respiratory monitoring system based on a Kinect device with a custom-made simple marker. A 3D respiratory monitoring system comprising the simple marker and the Microsoft Kinect v2 device was developed. The marker was designed for simple and robust detection, and the tracking algorithm was developed using the depth, RGB, and infra-red images acquired from the Kinect sensor. A Kalman filter was used to suppress movement noises. The major movements of the marker attached to the four different locations of body surface were determined from the initially collected tracking points of the marker while breathing. The signal level of respiratory motion with the tracking point was estimated along the major direction vector. The accuracy of the results was evaluated through a comparison with those of the conventional stereovision navigation system (NDI Polaris Spectra). Sixteen normal volunteers were enrolled to evaluate the accuracy of this system. The correlation coefficients between the respiratory motion signal from the Kinect device and conventional navigation system ranged from 0.970 to 0.999 and from 0.837 to 0.995 at the abdominal and thoracic surfaces, respectively. The respiratory motion signal from this system was obtained at 27-30 frames/s. This system with the Kinect v2 device and simple marker could be used for cost-effective, robust and accurate 3D respiratory motion monitoring. In addition, this system is as reliable for respiratory motion signal generation and as practically useful as the conventional stereovision navigation system and is less sensitive to patient posture. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A chest radiograph scoring system in patients with severe acute respiratory infection: a validation study

    Taylor, Emma; Haven, Kathryn; Reed, Peter; Bissielo, Ange; Harvey, Dave; McArthur, Colin; Bringans, Cameron; Freundlich, Simone; Ingram, R. Joan H.; Perry, David; Wilson, Francessa; Milne, David; Modahl, Lucy; Huang, Q. Sue; Gross, Diane; Widdowson, Marc-Alain; Grant, Cameron C.

    2015-01-01

    The term severe acute respiratory infection (SARI) encompasses a heterogeneous group of respiratory illnesses. Grading the severity of SARI is currently reliant on indirect disease severity measures such as respiratory and heart rate, and the need for oxygen or intensive care. With the lungs being the primary organ system involved in SARI, chest radiographs (CXRs) are potentially useful for describing disease severity. Our objective was to develop and validate a SARI CXR severity scoring system. We completed validation within an active SARI surveillance project, with SARI defined using the World Health Organization case definition of an acute respiratory infection with a history of fever, or measured fever of ≥ 38 °C; and cough; and with onset within the last 10 days; and requiring hospital admission. We randomly selected 250 SARI cases. Admission CXR findings were categorized as: 1 = normal; 2 = patchy atelectasis and/or hyperinflation and/or bronchial wall thickening; 3 = focal consolidation; 4 = multifocal consolidation; and 5 = diffuse alveolar changes. Initially, four radiologists scored CXRs independently. Subsequently, a pediatrician, physician, two residents, two medical students, and a research nurse independently scored CXR reports. Inter-observer reliability was determined using a weighted Kappa (κ) for comparisons between radiologists; radiologists and clinicians; and clinicians. Agreement was defined as moderate (κ > 0.4–0.6), good (κ > 0.6–0.8) and very good (κ > 0.8–1.0). Agreement between the two pediatric radiologists was very good (κ = 0.83, 95 % CI 0.65–1.00) and between the two adult radiologists was good (κ = 0.75, 95 % CI 0.57–0. 93). Agreement of the clinicians with the radiologists was moderate-to-good (pediatrician:κ = 0.65; pediatric resident:κ = 0.69; physician:κ = 0.68; resident:κ = 0.67; research nurse:κ = 0.49, medical students: κ = 0.53 and κ = 0.56). Agreement between clinicians was good-to-very good

  9. Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients.

    Wirth, Steffen; Biesemann, Andreas; Spaeth, Johannes; Schumann, Stefan

    2017-02-01

    Pneumoperitoneum during laparoscopic surgery leads to atelectasis and impairment of oxygenation. Positive end-expiratory pressure (PEEP) is supposed to counteract atelectasis. We hypothesized that the derecruiting effects of pneumoperitoneum would deteriorate the intratidal compliance profile in patients undergoing laparoscopic surgery. In 30 adult patients scheduled for surgery with pneumoperitoneum, respiratory variables were measured during mechanical ventilation. We calculated the dynamic compliance of the respiratory system (C RS ) and the intratidal volume-dependent C RS curve using the gliding-SLICE method. The C RS curve was then classified in terms of indicating intratidal recruitment/derecruitment (increasing profile) and overdistension (decreasing profile). During the surgical interventions, the PEEP level was maintained nearly constant at 7 cm H 2 O. Data are expressed as mean [confidence interval]. Baseline C RS was 60 [54-67] mL cm H 2 O -1 . Application of pneumoperitoneum decreased C RS to 40 [37-43] mL cm H 2 O -1 which partially recovered to 54 [50-59] mL cm H 2 O -1 (P < 0.001) after removal but remained below the value measured before pneumoperitoneum (P < 0.001). Baseline compliance profiles indicated intratidal recruitment/derecruitment in 48 % patients. After induction of pneumoperitoneum, intratidal recruitment/derecruitment was indicated in 93 % patients (P < 0.01), and after removal intratidal recruitment/derecruitment was indicated in 59 % patients. Compliance profiles showing overdistension were not observed. Analyses of the intratidal compliance profiles reveal that pneumoperitoneum during laparoscopic surgery causes intratidal recruitment/derecruitment which partly persists after its removal. The analysis of the intratidal volume-dependent C RS profiles could be used to guide intraoperative PEEP adjustments during elevated intraabdominal pressure.

  10. Neurofeedback of SMR and Beta1 Frequencies: An Investigation of Learning Indices and Frequency-Specific Effects.

    Pimenta, Miguel G; van Run, Chris; de Fockert, Jan W; Gruzelier, John H

    2018-05-15

    Despite evidence that Sensorimotor Rhythm (SMR) and beta1 neurofeedback have distinct cognitive enhancement effects, it remains unclear whether their amplitudes can be independently enhanced. Furthermore, demands for top-down attention control, postural restraint and maintenance of cognitive set processes, all requiring low-beta frequencies, might masquerade as learning and confound interpretation. The feasibility of selectively enhancing SMR and beta1 amplitudes was investigated with the addition of a random frequency control condition that also requires the potentially confounding cognitive processes. A comprehensive approach to assessing neurofeedback learning was undertaken through the calculation of learning indices within- and across-session and pre-to-post baseline. Herein we provide the first demonstration of beta1 within-session amplitude learning that was not attributable to extraneous cognitive processes, for it was not found with random frequency training. On the other hand, within-session SMR learning might have been obscured by high interindividual variability and methodological limitations such as the type of feedback screen, the insufficient number of sessions, and the exclusion of simultaneous theta and high-beta inhibition. Interestingly, SMR and beta1 amplitude increased across sessions in the three groups suggesting unspecific effects of neurofeedback in the low beta frequency band. Moreover, there was no clear evidence of frequency specificity associated with either SMR or beta1 training. Some methodological limitations may underpin the divergent results with previous studies. Copyright © 2017 IBRO. All rights reserved.

  11. Response localization of the pharmacological agents histamine and salbutamol along the respiratory system by forced oscillations in asthmatic subjects.

    Wouters, E F; Polko, A H; Visser, B F

    1989-01-01

    The bronchodilating effect of 1 mg and 0.4 mg salbutamol on the impedance of the respiratory system was studied in 25 asthmatic subjects after histamine-induced bronchoconstriction. Histamine caused an increase of respiratory resistance (Rrs) at lower frequencies and a frequency dependence of Rrs. Respiratory reactance (Xrs) decreased at all frequencies after histamine challenge. These changes can be explained by peripheral airway obstruction. Impedance measurements performed 5 min after inhalation of 1 mg and 0.4 mg salbutamol showed a decrease of Rrs values at lower frequencies, a disappearance of the frequency dependence of Rrs, and a significant increase of Xrs values. No significant differences in absolute changes of Rrs and Xrs are observed between the salbutamol regimens. These changes after inhalation of salbutamol can be explained by supposing a predominant action on the peripheral airways.

  12. Aspiration pneumonia induces muscle atrophy in the respiratory, skeletal, and swallowing systems.

    Komatsu, Riyo; Okazaki, Tatsuma; Ebihara, Satoru; Kobayashi, Makoto; Tsukita, Yoko; Nihei, Mayumi; Sugiura, Hisatoshi; Niu, Kaijun; Ebihara, Takae; Ichinose, Masakazu

    2018-05-22

    Repetition of the onset of aspiration pneumonia in aged patients is common and causes chronic inflammation. The inflammation induces proinflammatory cytokine production and atrophy in the muscles. The proinflammatory cytokines induce muscle proteolysis by activating calpains and caspase-3, followed by further degradation by the ubiquitin-proteasome system. Autophagy is another pathway of muscle atrophy. However, little is known about the relationship between aspiration pneumonia and muscle. For swallowing muscles, it is not clear whether they produce cytokines. The main objective of this study was to determine whether aspiration pneumonia induces muscle atrophy in the respiratory (the diaphragm), skeletal (the tibialis anterior, TA), and swallowing (the tongue) systems, and their possible mechanisms. We employed a mouse aspiration pneumonia model and computed tomography (CT) scans of aged pneumonia patients. To induce aspiration pneumonia, mice were inoculated with low dose pepsin and lipopolysaccharide solution intra-nasally 5 days a week. The diaphragm, TA, and tongue were isolated, and total RNA, proteins, and frozen sections were stored. Quantitative real-time polymerase chain reaction determined the expression levels of proinflammatory cytokines, muscle E3 ubiquitin ligases, and autophagy related genes. Western blot analysis determined the activation of the muscle proteolysis pathway. Frozen sections determined the presence of muscle atrophy. CT scans were used to evaluate the muscle atrophy in aged aspiration pneumonia patients. The aspiration challenge enhanced the expression levels of proinflammatory cytokines in the diaphragm, TA, and tongue. Among muscle proteolysis pathways, the aspiration challenge activated caspase-3 in all the three muscles examined, whereas calpains were activated in the diaphragm and the TA but not in the tongue. Activation of the ubiquitin-proteasome system was detected in all the three muscles examined. The aspiration challenge

  13. A biophysical model of the mitochondrial respiratory system and oxidative phosphorylation.

    Daniel A Beard

    2005-09-01

    Full Text Available A computational model for the mitochondrial respiratory chain that appropriately balances mass, charge, and free energy transduction is introduced and analyzed based on a previously published set of data measured on isolated cardiac mitochondria. The basic components included in the model are the reactions at complexes I, III, and IV of the electron transport system, ATP synthesis at F1F0 ATPase, substrate transporters including adenine nucleotide translocase and the phosphate-hydrogen co-transporter, and cation fluxes across the inner membrane including fluxes through the K+/H+ antiporter and passive H+ and K+ permeation. Estimation of 16 adjustable parameter values is based on fitting model simulations to nine independent data curves. The identified model is further validated by comparison to additional datasets measured from mitochondria isolated from rat heart and liver and observed at low oxygen concentration. To obtain reasonable fits to the available data, it is necessary to incorporate inorganic-phosphate-dependent activation of the dehydrogenase activity and the electron transport system. Specifically, it is shown that a model incorporating phosphate-dependent activation of complex III is able to reasonably reproduce the observed data. The resulting validated and verified model provides a foundation for building larger and more complex systems models and investigating complex physiological and pathophysiological interactions in cardiac energetics.

  14. A Biophysical Model of the Mitochondrial Respiratory System and Oxidative Phosphorylation.

    2005-09-01

    Full Text Available A computational model for the mitochondrial respiratory chain that appropriately balances mass, charge, and free energy transduction is introduced and analyzed based on a previously published set of data measured on isolated cardiac mitochondria. The basic components included in the model are the reactions at complexes I, III, and IV of the electron transport system, ATP synthesis at F(1F(0 ATPase, substrate transporters including adenine nucleotide translocase and the phosphate-hydrogen co-transporter, and cation fluxes across the inner membrane including fluxes through the K/H antiporter and passive H and K permeation. Estimation of 16 adjustable parameter values is based on fitting model simulations to nine independent data curves. The identified model is further validated by comparison to additional datasets measured from mitochondria isolated from rat heart and liver and observed at low oxygen concentration. To obtain reasonable fits to the available data, it is necessary to incorporate inorganic-phosphate-dependent activation of the dehydrogenase activity and the electron transport system. Specifically, it is shown that a model incorporating phosphate-dependent activation of complex III is able to reasonably reproduce the observed data. The resulting validated and verified model provides a foundation for building larger and more complex systems models and investigating complex physiological and pathophysiological interactions in cardiac energetics.

  15. Quality assurance for respiratory-gated stereotactic body radiation therapy in lung using real-time position management system

    Nakaguchi, Yuji; Maruyama, Masato; Araki, Fujio; Kouno, Tomohiro

    2012-01-01

    In this study, we investigated comprehensive quality assurance (QA) for respiratory-gated stereotactic body radiation therapy (SBRT) in the lungs using a real-time position management system (RPM). By using the phantom study, we evaluated dose liberality and reproducibility, and dose distributions for low monitor unite (MU), and also checked the absorbed dose at isocenter and dose profiles for the respiratory-gated exposure using RPM. Furthermore, we evaluated isocenter dose and dose distributions for respiratory-gated SBRT plans in the lungs using RPM. The maximum errors for the dose liberality were 4% for 2 MU, 1% for 4-10 MU, and 0.5% for 15 MU and 20 MU. The dose reproducibility was 2% for 1 MU and within 0.1% for 5 MU or greater. The accuracy for dose distributions was within 2% for 2 MU or greater. The dose error along a central axis for respiratory cycles of 2, 4, and 6 sec was within 1%. As for geometric accuracy, 90% and 50% isodose areas for the respiratory-gated exposure became almost 1 mm and 2 mm larger than without gating, respectively. For clinical lung-SBRT plans, the point dose at isocenter agreed within 2.1% with treatment planning system (TPS). And the pass rates of all plans for TPS were more than 96% in the gamma analysis (3 mm/3%). The geometrical accuracy and the dose accuracy of TPS calculation algorithm are more important for the dose evaluation at penumbra region for respiratory-gated SBRT in lung using RPM. (author)

  16. SMR and economics competitiveness in small grids. A real option analysis

    Locatelli, Giorgio; Mancino, Mauro; Lotti, Giovanni

    2014-01-01

    The optimal investment in power plants depends on many uncertain parameters (price of electricity, construction costs, cost of emissions, fuel cost..). Traditional approaches based on the Discounted Cash Flows methodologies, like the Net Present Value (NPV), do not properly take into account these uncertainties since they depend on the implicit assumption that all the decisions regarding the investment are evaluated in a specific moment (the time now) and cannot be postponed, waiting to acquire more information. An evolution of these methods is the Real Options Analysis (ROA) that considers a further value into the evaluation: the value of flexibility to choose when to invest. In this paper the ROA will be used to test a hypothesis made in literature, that small-medium sized plants (300-400 MWe) can be a suitable choice for small grids (or markets), thanks to their flexibility in the deployment. The assessment of this hypothesis is based on a ROA model that compares the investment in a Large Reactor (LR) vs. a group of Small Modular Reactors (SMR). Montecarlo simulations are used to approximate the probability distributions of the profitability indicators, both with a static approach, implying that investments are made immediately, and with a dynamic approach, letting the model decide when to invest (optimizing the profitability distribution). The result show as SMR, in small grid, can yield similar profitability in lower risky conditions. (orig.)

  17. SMR and economics competitiveness in small grids. A real option analysis

    Locatelli, Giorgio [University of Lincoln - School of Engineering, Lincoln (United Kingdom). Faculty of Science; Mancino, Mauro; Lotti, Giovanni [Politecnico di Milano (Italy). Dept. of Management Economics and Industrial Engineering

    2014-03-15

    The optimal investment in power plants depends on many uncertain parameters (price of electricity, construction costs, cost of emissions, fuel cost..). Traditional approaches based on the Discounted Cash Flows methodologies, like the Net Present Value (NPV), do not properly take into account these uncertainties since they depend on the implicit assumption that all the decisions regarding the investment are evaluated in a specific moment (the time now) and cannot be postponed, waiting to acquire more information. An evolution of these methods is the Real Options Analysis (ROA) that considers a further value into the evaluation: the value of flexibility to choose when to invest. In this paper the ROA will be used to test a hypothesis made in literature, that small-medium sized plants (300-400 MWe) can be a suitable choice for small grids (or markets), thanks to their flexibility in the deployment. The assessment of this hypothesis is based on a ROA model that compares the investment in a Large Reactor (LR) vs. a group of Small Modular Reactors (SMR). Montecarlo simulations are used to approximate the probability distributions of the profitability indicators, both with a static approach, implying that investments are made immediately, and with a dynamic approach, letting the model decide when to invest (optimizing the profitability distribution). The result show as SMR, in small grid, can yield similar profitability in lower risky conditions. (orig.)

  18. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Jacques Hugo; John Forester; David Gertman; Jeffrey Joe; Heather Medema; Julius Persensky; April Whaley

    2013-04-01

    This report presents preliminary research results from the investigation in to the development of new models and guidance for concepts of operations (ConOps) in advanced small modular reactor (aSMR) designs. In support of this objective, three important research areas were included: operating principles of multi-modular plants, functional allocation models and strategies that would affect the development of new, non-traditional concept of operations, and the requiremetns for human performance, based upon work domain analysis and current regulatory requirements. As part of the approach for this report, we outline potential functions, including the theoretical and operational foundations for the development of a new functional allocation model and the identification of specific regulatory requirements that will influence the development of future concept of operations. The report also highlights changes in research strategy prompted by confirmationof the importance of applying the work domain analysis methodology to a reference aSMR design. It is described how this methodology will enrich the findings from this phase of the project in the subsequent phases and help in identification of metrics and focused studies for the determination of human performance criteria that can be used to support the design process.

  19. Isolation and identification of antibiotic resistance genes in Staphylococcus aureus isolates from respiratory system infections in shahrekord, Iran

    Maryam Reisi

    2014-07-01

    Full Text Available   Introduction : Staphylococcus aureus is considered as one of pathogenic agents in humans, that engages different body parts including respiratory system and causes to spend lots of costs and extending patient’s treatment period. This study which is performed to separate and investigate the pattern of antibiotic resistance in Staphylococcus aureus isolates from upper respiratory system infections in Shahrekord.   Materials and methods: This study was done by sectional-descriptive method On 200 suspicious persons to the upper respiratory system infections who were referred to the Imam Ali clinic in Shahrekord in 2012. After isolation of Staphylococcus aureus from cultured nose discharges, antibiotic resistance genes were identified by polymerase chain reaction (PCR by using defined primer pairs .   Results : Among 200 investigated samples in 60 cases (30% Staphylococcus aureus infection (by culturing and PCR method was determined. Isolates showed the lowest amount of antibiotic resistance to vancomycin (0.5% and the highest amount of resistance to the penicillin G and cefotaxime (100%. mecA gene (encoding methicillin resistance with frequency of 85.18% and aacA-D gene (encoding resistance to aminoglycosides with frequency of 28.33% showed the highest and lowest frequency of antibiotic resistance genes coding in Staphylococcus aureus isolates respectively .   Discussion and conclusion : Notable prevalence of resistant Staphylococcus aureus isolates in community acquired respiratory infections, recommend continuous control necessity to impede the spreading of these bacteria and their infections.  

  20. Effect of a Health Care System Respiratory Fluoroquinolone Restriction Program To Alter Utilization and Impact Rates of Clostridium difficile Infection.

    Shea, Katherine M; Hobbs, Athena L V; Jaso, Theresa C; Bissett, Jack D; Cruz, Christopher M; Douglass, Elizabeth T; Garey, Kevin W

    2017-06-01

    Fluoroquinolones are one of the most commonly prescribed antibiotic classes in the United States despite their association with adverse consequences, including Clostridium difficile infection (CDI). We sought to evaluate the impact of a health care system antimicrobial stewardship-initiated respiratory fluoroquinolone restriction program on utilization, appropriateness of quinolone-based therapy based on institutional guidelines, and CDI rates. After implementation, respiratory fluoroquinolone utilization decreased from a monthly mean and standard deviation (SD) of 41.0 (SD = 4.4) days of therapy (DOT) per 1,000 patient days (PD) preintervention to 21.5 (SD = 6.4) DOT/1,000 PD and 4.8 (SD = 3.6) DOT/1,000 PD posteducation and postrestriction, respectively. Using segmented regression analysis, both education (14.5 DOT/1,000 PD per month decrease; P = 0.023) and restriction (24.5 DOT/1,000 PD per month decrease; P cost of moxifloxacin, the formulary respiratory fluoroquinolone, was observed postrestriction compared to preintervention within the health care system ($123,882 versus $12,273; P = 0.002). Implementation of a stewardship-initiated respiratory fluoroquinolone restriction program can increase appropriate use while reducing overall utilization, acquisition cost, and CDI rates within a health care system. Copyright © 2017 American Society for Microbiology.

  1. Assessment of a volume-dependent dynamic respiratory system compliance in ALI/ARDS by pooling breathing cycles

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    New methods were developed to calculate the volume-dependent dynamic respiratory system compliance (C rs ) in mechanically ventilated patients. Due to noise in respiratory signals and different characteristics of the methods, their results can considerably differ. The aim of the study was to establish a practical procedure to validate the estimation of intratidal dynamic C rs . A total of 28 patients from intensive care units of eight German university hospitals with acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) were studied retrospectively. Dynamic volume-dependent C rs was determined during ongoing mechanical ventilation with the SLICE method, dynostatic algorithm and adaptive slice method. Conventional two-point compliance C 2P was calculated for comparison. A number of consecutive breathing cycles were pooled to reduce noise in the respiratory signals. C rs -volume curves produced with different methods converged when the number of pooling cycles increased (n ≥ 7). The mean volume-dependent C rs of 20 breaths was highly correlated with mean C 2P (C 2P,mean = 0.945 × C rs,mean − 0.053, r 2 = 0.968, p < 0.0001). The Bland–Altman analysis indicated that C 2P,mean was lower than C rs,mean (−2.4 ± 6.4 ml cm −1 H 2 O, mean bias ± 2 SD), but not significant according to the paired t-test (p > 0.05). Methods for analyzing dynamic respiratory mechanics are sensitive to noise and will converge to a unique solution when the number of pooled cycles increases. Under steady-state conditions, assessment of the volume-dependent C rs in ALI/ARDS patients can be validated by pooling respiratory data of consecutive breaths regardless of which method is applied. Confidence in dynamic C rs determination may be increased with the proposed pooling. (note)

  2. Human nasal turbinates as a viable source of respiratory epithelial cells using co-culture system versus dispase-dissociation technique.

    Noruddin, Nur Adelina Ahmad; Saim, Aminuddin B; Chua, Kien Hui; Idrus, Ruszymah

    2007-12-01

    To compare a co-culture system with a conventional dispase-dissociation method for obtaining functional human respiratory epithelial cells from the nasal turbinates for tissue engineering application. Human respiratory epithelial cells were serially passaged using a co-culture system and a conventional dispase-dissociation technique. The growth kinetics and gene expression levels of the cultured respiratory epithelial cells were compared. Four genes were investigated, namely cytokeratin-18, a marker for ciliated and secretory epithelial cells; cytokeratin-14, a marker for basal epithelial cells; MKI67, a proliferation marker; and MUC5B, a marker for mucin secretion. Immunocytochemical analysis was performed using monoclonal antibodies against the high molecular-weight cytokeratin 34 beta E12, cytokeratin 18, and MUC5A to investigate the protein expression from cultured respiratory epithelial cells. Respiratory epithelial cells cultured using both methods maintained polygonal morphology throughout the passages. At passage 1, co-cultured respiratory epithelial showed a 2.6-times higher growth rate compared to conventional dispase dissociation technique, and 7.8 times higher at passage 2. Better basal gene expression was observed by co-cultured respiratory epithelial cells compared to dispase dissociated cells. Immunocytochemical analyses were positive for the respiratory epithelial cells cultured using both techniques. Co-culture system produced superior quality of cultured human respiratory epithelial cells from the nasal turbinates as compared to dispase dissociation technique.

  3. Transmissibility of the monkeypox virus clades via respiratory transmission: investigation using the prairie dog-monkeypox virus challenge system.

    Christina L Hutson

    Full Text Available Monkeypox virus (MPXV is endemic within Africa where it sporadically is reported to cause outbreaks of human disease. In 2003, an outbreak of human MPXV occurred in the US after the importation of infected African rodents. Since the eradication of smallpox (caused by an orthopoxvirus (OPXV related to MPXV and cessation of routine smallpox vaccination (with the live OPXV vaccinia, there is an increasing population of people susceptible to OPXV diseases. Previous studies have shown that the prairie dog MPXV model is a functional animal model for the study of systemic human OPXV illness. Studies with this model have demonstrated that infected animals are able to transmit the virus to naive animals through multiple routes of exposure causing subsequent infection, but were not able to prove that infected animals could transmit the virus exclusively via the respiratory route. Herein we used the model system to evaluate the hypothesis that the Congo Basin clade of MPXV is more easily transmitted, via respiratory route, than the West African clade. Using a small number of test animals, we show that transmission of viruses from each of the MPXV clade was minimal via respiratory transmission. However, transmissibility of the Congo Basin clade was slightly greater than West African MXPV clade (16.7% and 0% respectively. Based on these findings, respiratory transmission appears to be less efficient than those of previous studies assessing contact as a mechanism of transmission within the prairie dog MPXV animal model.

  4. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  5. Respiratory Failure

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, ... brain, need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can' ...

  6. Neurological Respiratory Failure

    Mohan Rudrappa

    2018-01-01

    Full Text Available West Nile virus infection in humans is mostly asymptomatic. Less than 1% of neuro-invasive cases show a fatality rate of around 10%. Acute flaccid paralysis of respiratory muscles leading to respiratory failure is the most common cause of death. Although the peripheral nervous system can be involved, isolated phrenic nerve palsy leading to respiratory failure is rare and described in only two cases in the English literature. We present another case of neurological respiratory failure due to West Nile virus-induced phrenic nerve palsy. Our case reiterates the rare, but lethal, consequences of West Nile virus infection, and the increase of its awareness among physicians.

  7. Anatomy of Respiratory Rhythmic Systems in Brain Stem and Cerebellum of the Carp

    Jüch, P.J.W.; Luiten, P.G.M.

    1981-01-01

    The afferent and efferent connections of two respiratory rhythmic loci in the dorsal mesencephalic tegmentum were studied by retrograde and anterograde transport of horseradish peroxidase. The injection areas were determined with extracellular activity recording using HRP filled glass micropipettes,

  8. Porcine reproductive and respiratory syndrome virus (PRRSV): pathogenesis and interaction with the immune System

    This review addresses important issues of porcine reproductive and respiratory syndrome virus (PRRSV) infection, immunity, pathogenesis and control. Worldwide PRRS is the most economically important infectious disease of pigs. We highlight the latest information on viral genome structure, pathogenic...

  9. Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

    Kondwani Kawaza

    Full Text Available Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care.We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups.87 neonates (62 bCPAP, 25 controls were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62 compared with 44.0% (11/25 for controls. 65.5% (19/29 of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13 of controls. 64.6% (31/48 of neonates with respiratory distress syndrome (RDS receiving bCPAP survived to discharge, compared to 23.5% (4/17 of controls. 61.5% (16/26 of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived.Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries.

  10. Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

    Kawaza, Kondwani; Machen, Heather E; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; Smith, E O'Brian; Oden, Maria; Richards-Kortum, Rebecca R; Molyneux, Elizabeth

    2014-01-01

    Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries.

  11. Development of a Respiratory Inductive Plethysmography Module Supporting Multiple Sensors for Wearable Systems

    Zhengbo Zhang

    2012-09-01

    Full Text Available In this paper, we present an RIP module with the features of supporting multiple inductive sensors, no variable frequency LC oscillator, low power consumption, and automatic gain adjustment for each channel. Based on the method of inductance measurement without using a variable frequency LC oscillator, we further integrate pulse amplitude modulation and time division multiplexing scheme into a module to support multiple RIP sensors. All inductive sensors are excited by a high-frequency electric current periodically and momentarily, and the inductance of each sensor is measured during the time when the electric current is fed to it. To improve the amplitude response of the RIP sensors, we optimize the sensing unit with a matching capacitor parallel with each RIP sensor forming a frequency selection filter. Performance tests on the linearity of the output with cross-sectional area and the accuracy of respiratory volume estimation demonstrate good linearity and accurate lung volume estimation. Power consumption of this new RIP module with two sensors is very low. The performance of respiration measurement during movement is also evaluated. This RIP module is especially desirable for wearable systems with multiple RIP sensors for long-term respiration monitoring.

  12. Respiratory behavior of turning stage mature tomato (Solanum lycopersicum L. under closed system at different temperature

    Ranjeet Singh

    2013-01-01

    Full Text Available The respiration rate and respiratory quotient of mature tomato (Solanum lycopersicum L. cv. ‘Himsona’ fruits harvested at the turning stage were determined under closed system at 5, 10, 15, 20, 25 and 35 °C (ambient temperatures. The rate of respiration was higher at the start of the experiment and gradually declined as the storage period prolonged, before becoming almost constant. The steady-state respiration rate for CO2 evolution were observed to be 14.35, 15.04,19.95, 21.7 and 20.3 ml/kg-h at 10 °C, 15 °C, 20 °C, 25 °C and 35 °C, respectively. The RQ values for tomato varied from 0.55 to 1.10 with time under the experimental conditions. The respiration rate at steady state based on carbon dioxide evolution and oxygen consumption in closed condition decreased by about 46 % and 73 %, respectively relative to initial respiration rate values at normal air atmosphere. The results suggest that the respiration rate of tomato increased with temperature and decrease with storage time.

  13. Respiratory system loop gain in normal men and women measured with proportional-assist ventilation.

    Wellman, Andrew; Malhotra, Atul; Fogel, Robert B; Edwards, Jill K; Schory, Karen; White, David P

    2003-01-01

    We hypothesized that increased chemical control instability (CCI) in men could partially explain the male predominance in obstructive sleep apnea (OSA). CCI was assessed by sequentially increasing respiratory control system loop gain (LG) with proportional-assist ventilation (PAV) in 10 men (age 24-48 yr) and 9 women (age 22-36 yr) until periodic breathing or awakening occurred. Women were studied in both the follicular and luteal phases of the menstrual cycle. The amount by which PAV amplified LG was quantified from the tidal volume amplification factor [(VtAF) assisted tidal volume/unassisted tidal volume]. LG was calculated as the inverse of the VtAF occurring at the assist level immediately preceding the emergence of periodic breathing (when LG x VtAF = 1). Only 1 of 10 men and 2 of 9 women developed periodic breathing with PAV. The rest were resistant to periodic breathing despite moderately high levels of PAV amplification. We conclude that LG is low in the majority of normal men and women and that higher volume amplification factors are needed to determine whether gender differences exist in this low range.

  14. Pathogenesis of H5N1 influenza virus infections in mice and ferret models differ between respiratory and digestive system exposure

    Background. Epidemiological, clinical and laboratory data suggests H5N1 influenza viruses are transmitted through and predominantly affect the respiratory system of mammals. Some data suggests digestive system involvement. However, direct evidence of alimentary transmission and infection in mammal...

  15. Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

    Hoogeman, Mischa; Prevost, Jean-Briac; Nuyttens, Joost; Poell, Johan; Levendag, Peter; Heijmen, Ben

    2009-01-01

    Purpose: To quantify the clinical accuracy of the respiratory motion tracking system of the CyberKnife treatment device. Methods and Materials: Data in log files of 44 lung cancer patients treated with tumor tracking were analyzed. Errors in the correlation model, which relates the internal target motion with the external breathing motion, were quantified. The correlation model error was compared with the geometric error obtained when no respiratory tracking was used. Errors in the prediction method were calculated by subtracting the predicted position from the actual measured position after 192.5 ms (the time lag to prediction in our current system). The prediction error was also measured for a time lag of 115 ms and a new prediction method. Results: The mean correlation model errors were less than 0.3 mm. Standard deviations describing intrafraction variations around the whole-fraction mean error were 0.2 to 1.9 mm for cranio-caudal, 0.1 to 1.9 mm for left-right, and 0.2 to 2.5 mm for anterior-posterior directions. Without the use of respiratory tracking, these variations would have been 0.2 to 8.1 mm, 0.2 to 5.5 mm, and 0.2 to 4.4 mm. The overall mean prediction error was small (0.0 ± 0.0 mm) for all directions. The intrafraction standard deviation ranged from 0.0 to 2.9 mm for a time delay of 192.5 ms but was halved by using the new prediction method. Conclusions: Analyses of the log files of real clinical cases have shown that the geometric error caused by respiratory motion is substantially reduced by the application of respiratory motion tracking.

  16. Extraction and Analysis of Respiratory Motion Using Wearable Inertial Sensor System during Trunk Motion

    Apoorva Gaidhani

    2017-12-01

    Full Text Available Respiratory activity is an essential vital sign of life that can indicate changes in typical breathing patterns and irregular body functions such as asthma and panic attacks. Many times, there is a need to monitor breathing activity while performing day-to-day functions such as standing, bending, trunk stretching or during yoga exercises. A single IMU (inertial measurement unit can be used in measuring respiratory motion; however, breathing motion data may be influenced by a body trunk movement that occurs while recording respiratory activity. This research employs a pair of wireless, wearable IMU sensors custom-made by the Department of Electrical Engineering at San Diego State University. After appropriate sensor placement for data collection, this research applies principles of robotics, using the Denavit-Hartenberg convention, to extract relative angular motion between the two sensors. One of the obtained relative joint angles in the “Sagittal” plane predominantly yields respiratory activity. An improvised version of the proposed method and wearable, wireless sensors can be suitable to extract respiratory information while performing sports or exercises, as they do not restrict body motion or the choice of location to gather data.

  17. The effect of artichoke (Cynara scolymus L.) extract on respiratory chain system activity in rat liver mitochondria.

    Juzyszyn, Z; Czerny, B; Myśliwiec, Z; Pawlik, A; Droździk, M

    2010-06-01

    The effect of artichoke extract on mitochondrial respiratory chain (MRC) activity in isolated rat liver mitochondria (including reaction kinetics) was studied. The effect of the extract on the activity of isolated cytochrome oxidase was also studied. Extract in the range of 0.68-2.72 microg/ml demonstrated potent and concentration-dependent inhibitory activity. Concentrations > or =5.4 microg/ml entirely inhibited MRC activity. The succinate oxidase system (MRC complexes II-IV) was the most potently inhibited, its activity at an extract concentration of 1.36 microg/ml being reduced by 63.3% compared with the control (p artichoke extracts may rely in part on the effects of their active compounds on the activity of the mitochondrial respiratory chain system.

  18. The microbiota of the respiratory tract : Gatekeeper to respiratory health

    Man, Wing Ho; De Steenhuijsen Piters, Wouter A.A.; Bogaert, Debby

    2017-01-01

    The respiratory tract is a complex organ system that is responsible for the exchange of oxygen and carbon dioxide. The human respiratory tract spans from the nostrils to the lung alveoli and is inhabited by niche-specific communities of bacteria. The microbiota of the respiratory tract probably acts

  19. Reductions in the variations of respiration signals for respiratory-gated radiotherapy when using the video-coaching respiration guiding system

    Lee, Hyun Jeong; Yea, Ji Woon; Oh, Se An

    2015-07-01

    Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT by using a video-coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by using a realtime position management (RPM) respiratory gating system (Varian, USA), and the patients were trained using the video-coaching respiration guiding system. The patients performed free breathing and guided breathing, and the respiratory cycles were acquired for ~5 min. Then, Microsoft Excel 2010 software was used to calculate the mean and the standard deviation for each phase. The standard deviation was computed in order to analyze the improvement in the respiratory regularity with respect to the period and the displacement. The standard deviation of the guided breathing decreased to 48.8% in the inhale peak and 24.2% in the exhale peak compared with the values for the free breathing of patient 6. The standard deviation of the respiratory cycle was found to be decreased when using the respiratory guiding system. The respiratory regularity was significantly improved when using the video-coaching respiration guiding system. Therefore, the system is useful for improving the accuracy and the efficiency of RGRT.

  20. Evaluation of the Educational Value of YouTube Videos About Physical Examination of the Cardiovascular and Respiratory Systems

    Azer, Samy A; AlGrain, Hala A; AlKhelaif, Rana A; AlEshaiwi, Sarah M

    2013-01-01

    Background A number of studies have evaluated the educational contents of videos on YouTube. However, little analysis has been done on videos about physical examination. Objective This study aimed to analyze YouTube videos about physical examination of the cardiovascular and respiratory systems. It was hypothesized that the educational standards of videos on YouTube would vary significantly. Methods During the period from November 2, 2011 to December 2, 2011, YouTube was searched by three ass...

  1. Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System® to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome.

    Akkanti, Bindu; Rajagopal, Keshava; Patel, Kirti P; Aravind, Sangeeta; Nunez-Centanu, Emmanuel; Hussain, Rahat; Shabari, Farshad Raissi; Hofstetter, Wayne L; Vaporciyan, Ara A; Banjac, Igor S; Kar, Biswajit; Gregoric, Igor D; Loyalka, Pranav

    2017-06-01

    Extracorporeal carbon dioxide removal (ECCO 2 R) permits reductions in alveolar ventilation requirements that the lungs would otherwise have to provide. This concept was applied to a case of hypercapnia refractory to high-level invasive mechanical ventilator support. We present a case of an 18-year-old man who developed post-pneumonectomy acute respiratory distress syndrome (ARDS) after resection of a mediastinal germ cell tumor involving the left lung hilum. Hypercapnia and hypoxemia persisted despite ventilator support even at traumatic levels. ECCO 2 R using a miniaturized system was instituted and provided effective carbon dioxide elimination. This facilitated establishment of lung-protective ventilator settings and lung function recovery. Extracorporeal lung support increasingly is being applied to treat ARDS. However, conventional extracorporeal membrane oxygenation (ECMO) generally involves using large cannulae capable of carrying high flow rates. A subset of patients with ARDS has mixed hypercapnia and hypoxemia despite high-level ventilator support. In the absence of profound hypoxemia, ECCO 2 R may be used to reduce ventilator support requirements to lung-protective levels, while avoiding risks associated with conventional ECMO.

  2. Determination of respiratory system compliance during pressure support ventilation by small variations of pressure support.

    Becher, Tobias; Schädler, Dirk; Rostalski, Philipp; Zick, Günther; Frerichs, Inéz; Weiler, Norbert

    2017-09-22

    In mechanically ventilated patients, measurement of respiratory system compliance (C rs ) is of high clinical interest. Spontaneous breathing activity during pressure support ventilation (PSV) can impede the correct assessment of C rs and also alter the true C rs by inducing lung recruitment. We describe a method for determination of C rs during PSV and assess its accuracy in a study on 20 mechanically ventilated patients. To assess C rs during pressure support ventilation (C rs,PSV ), we performed repeated changes in pressure support level by ± 2 cmH 2 O. C rs,PSV was calculated from the volume change induced by these changes in pressure support level, taking into account the inspiration time and the expiratory time constant. As reference methods, we used C rs , measured during volume controlled ventilation (C rs,VCV ). In a post-hoc analysis, we assessed C rs during the last 20% of the volume-controlled inflation (C rs,VCV20 ). Values were compared by linear regression and Bland-Altman methods comparison. Comparing C rs,PSV to the reference value C rs,VCV , we found a coefficient of determination (r 2 ) of 0.90, but a relatively high bias of - 7 ml/cm H 2 O (95% limits of agreement - 16.7 to + 2.7 ml/cmH 2 O). Comparison with C rs,VCV20 resulted in a negligible bias (- 1.3 ml/cmH 2 O, 95% limits of agreement - 13.9 to + 11.3) and r 2 of 0.81. We conclude that the novel method provides an estimate of end-inspiratory C rs during PSV. Despite its limited accuracy, it might be useful for non-invasive monitoring of C rs in patients undergoing pressure support ventilation.

  3. Regulatory peptides in the upper respiratory system and oral cavity of man. An immunocytochemical and radioimmunological study

    Hauser-Kronberger, C.

    1992-01-01

    In the present study a dense network of peptide-immunoreactive nerve fibres in the upper respiratory system and the oral cavity of man was investigated. The occurrence, distribution and concentrations of regulatory peptide immunoreactivities in human nasal mucosa, soft palate, ventricular fold, vocal cord, epiglottis, subglottis, glandula submandibularis and glandula parotis were investigated using highly efficient immunocytochemical and radio-immunological methods. In the tissues investigated vasoactive intestinal polypeptide (VIP) and other derivatives from the VIP-precursor (peptide histidine methionine = PHM), prepro VIP (111-122)), neuropeptide tyrosine (NPY) and its C-flanking peptide (CPON), calcitonin gene-related peptide (CGRP), substance P, neurokinin A, bombesin-flanking peptide and somatostatin were detected. The regulatory peptides demonstrated also included the recently isolated peptides helospectin and pituitary adenylate cyclase activating peptide (PACAP). Single endocrine-like cells were for the first time demonstrated within the respiratory epithelium and in the lamina propria of the nasal mucosa and soft palate and in groups within ducts. Ultrastructural immunelectronmicroscopy was performed using an ABC-pre-embedding method. In addition, semithin Epon resin sections were immunostained. The concentrations of VIP, NPY, CGRP, substance P and neurokinin A were measured using radioimmunological methods. The peptide immunoreactivities demonstrated in a dense network of neuronal structures and endocrine cells give indication for the presence of a complex regulatory system with potent physiological mechanisms in the upper respiratory system and allocated tissues of man

  4. Bone histological correlates for air sacs and their implications for understanding the origin of the dinosaurian respiratory system.

    Lambertz, Markus; Bertozzo, Filippo; Sander, P Martin

    2018-01-01

    Air sacs are an important component of the avian respiratory system, and corresponding structures also were crucial for the evolution of sauropod dinosaur gigantism. Inferring the presence of air sacs in fossils so far is restricted to bones preserving internal pneumatic cavities and foramina as osteological correlates. We here present bone histological correlates for air sacs as a new potential identification tool for these elements of the respiratory system. The analysis of several avian and non-avian dinosaur samples revealed delicate fibres in secondary trabecular and secondary endosteal bone that in the former case (birds) is known or in the latter (non-avian dinosaurs) assumed to have been in contact with air sacs, respectively. The bone histology of this 'pneumosteal tissue' is markedly different from those regions where muscles attached presenting classical Sharpey's fibres. The pneumatized bones of several non-dinosaurian taxa do not exhibit the characteristics of this 'pneumosteum'. Our new histology-based approach thus can be instrumental in reconstructing the origin of air sacs among dinosaurs and hence for our understanding of this remarkable evolutionary novelty of the respiratory system. © 2018 The Author(s).

  5. MODERN MANAGEMENT OF ACUTE RESPIRATORY INFECTIONS IN CHILDREN. RECOURSES OF SYSTEM ANTI INFLAMMATORY TREATMENT

    O.V. Zaitseva

    2008-01-01

    Full Text Available A problem of etiology and pathogenesis of acute respiratory infections in children are observed in this article. Modern approach to management of its treatment in pediatric patients, including often ailing children, is described. Authors give characteristics to main directions of treatment of obstructive syndrome. An experience of anti-inflammatory therapy with fenspiride (eurespal in children of different age is summa ized in this article.Key words: often ailing children, acute respiratory infections, bronchoobstructive syndrome, anti-inflammatory treatment, fenspiride.

  6. Respiratory gating in cardiac PET

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... of our study was to compare the resulting imaging quality by the use of a time-based respiratory gating system in two groups administered either adenosine or dipyridamole as the pharmacological stress agent. METHODS AND RESULTS: Forty-eight patients were randomized to adenosine or dipyridamole cardiac...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4...

  7. Respiratory failure following anti-lung serum: study on mechanisms associated with surfactant system damage

    Lachmann, B.; Hallman, M.; Bergmann, K.C.

    1987-01-01

    Within 2 minutes intravenous anti-lung serum (ALS) into guinea pig induces a respiratory failure that is fatal within 30 min. The relationship between surfactant, alveolar-capillary permeability and respiratory failure was studied. Within two minutes ALS induced a leak in the alveolar-capillary barrier. Within 30 minutes 28.3% (controls, given normal rabbit serum: 0.7%) of iv 131 I-albumin, and 0.5% (controls 0.02%) of iv surfactant phospholipid tracer were recovered in bronchoalveolar lavage. Furthermore, 57% (controls 32%) of the endotracheally administered surfactant phospholipid became associated with lung tissue and only less than 0.5% left the lung. The distribution of proteins and phospholipids between the in vivo small volume bronchoalveolar lavages and the ex vivo bronchoalveolar lavages were dissimilar: 84% (controls 20%) of intravenously injected, lavageable 131 I-albumin and 23% (controls 18%) of total lavageable phospholipid were recovered in the in vivo small volume bronchoalveolar lavages. ALS also decreased lavageable surfactant phospholipid by 41%. After ALS the minimum surface tension increased. The supernatant of the lavage increased the minimum surface tension of normal surfactant. In addition, the sediment fraction of the lavage had slow surface adsorption, and a marked reduction in 35,000 and 10,000 MW peptides. Exogenous surfactant ameliorated the ALS-induced respiratory failure. We propose that inhibition, altered intrapulmonary distribution, and dissociation of protein and phospholipid components of surfactant are important in early pathogenesis of acute respiratory failure

  8. Amla Enhances Mitochondrial Spare Respiratory Capacity by Increasing Mitochondrial Biogenesis and Antioxidant Systems in a Murine Skeletal Muscle Cell Line

    Hirotaka Yamamoto

    2016-01-01

    Full Text Available Amla is one of the most important plants in Indian traditional medicine and has been shown to improve various age-related disorders while decreasing oxidative stress. Mitochondrial dysfunction is a proposed cause of aging through elevated oxidative stress. In this study, we investigated the effects of Amla on mitochondrial function in C2C12 myotubes, a murine skeletal muscle cell model with abundant mitochondria. Based on cell flux analysis, treatment with an extract of Amla fruit enhanced mitochondrial spare respiratory capacity, which enables cells to overcome various stresses. To further explore the mechanisms underlying these effects on mitochondrial function, we analyzed mitochondrial biogenesis and antioxidant systems, both proposed regulators of mitochondrial spare respiratory capacity. We found that Amla treatment stimulated both systems accompanied by AMPK and Nrf2 activation. Furthermore, we found that Amla treatment exhibited cytoprotective effects and lowered reactive oxygen species (ROS levels in cells subjected to t-BHP-induced oxidative stress. These effects were accompanied by increased oxygen consumption, suggesting that Amla protected cells against oxidative stress by using enhanced spare respiratory capacity to produce more energy. Thus we identified protective effects of Amla, involving activation of mitochondrial function, which potentially explain its various effects on age-related disorders.

  9. Development of respiratory motion reduction device system (RMRDs) for radiotherapy in moving tumors

    Lee, Suk; Yang, Dae-Sik; Choil, Myung-Sun; Kim, Chui-Yong

    2004-01-01

    The internal target volume (ITV) for tumors in the abdomen or thorax includes sufficient margin for breathing-related movement of tumor volumes during treatment. Depending on the location of the tumor, the magnitude of the ITV margin extends from 1 to 3 cm, which increases substantially the volume of the irradiated normal tissue, hence resulting in an increase in normal tissue complication probability (NTCP). We developed a simple and handy method which can reduce ITV margins in patients with moving tumors: the respiratory motion reduction device system (RMRDs). The patient's clinical database was structured for moving tumor patients and patient set-up error measurement and immobilization device effects were investigated. The system is composed of the respiration presser device (RPD) utilized in the prone position and the abdominal strip device (ASD) utilized in the supine position, and the analysis program, which enables analysis of patient set-up reproducibility. It was tested for analyzing the diaphragm movement from patients with RMRDs, the magnitude of the ITV margin was determined and the dose-volume histogram (DVH) was computed using treatment planning software. The dose to normal tissue in patients with and without RMRDs was analyzed by comparing the fraction of the normal liver receiving 50% of the isocenter dose. Average diaphragm movement due to respiration was 16±1.9 mm in the case of the supine position, and 12±1.9 mm in the case of the prone position. When utilizing the RMRDs, which was personally developed in our hospital, the value was reduced to 5±1.4 mm, and in the case in which the belt immobilization device was utilized, the value was reduced to 3±0.9 mm. In the case where the strip device was utilized, the value was proven to reduce to 4±0.3 mm. As a result of analyzing the volume of normal liver where 50% of the prescription dose is irradiated in DVH according to the radiation treatment planning, the use of the RMRD can create a reduction

  10. Combined effects of leaks, respiratory system properties and upper airway patency on the performance of home ventilators: a bench study.

    Zhu, Kaixian; Rabec, Claudio; Gonzalez-Bermejo, Jésus; Hardy, Sébastien; Aouf, Sami; Escourrou, Pierre; Roisman, Gabriel

    2017-11-21

    Combined effects of leaks, mechanical property of respiratory system and upper airway (UA) patency on patient-ventilator synchrony (PVA) and the level of clinically "tolerable" leaks are not well established in home ventilators. We comparatively assessed on a bench model, the highest leak level tolerated without inducing significant asynchrony ("critical leak") in three home ventilators (Astral 150, Trilogy 100 and Vivo 60; noted as A150, T100 and V60 respectively) subjected to three simulated diseased respiratory conditions: chronic obstructive pulmonary disease (COPD), obesity hypoventilation (OHS) and neuromuscular disorders (NMD), with both open and closed UA. Also, total leak values in the device reports were compared to the bench-measured values. With open UA, all ventilators were able to avoid asynchrony up to a 30 L/min leak and even to 55 L/min in some cases. UA closure and respiratory diseases especially OHS influenced PVA. With closed UA, the critical leak of A150 and T100 remained higher than 55 L/min in COPD and OHS, while for V60 decreased to 41 and 33 L/min respectively. In NMD with closed UA, only T100 reached a high critical leak of 69 L/min. Besides, inspiratory trigger sensitivity change was often necessary to avoid PVA. Home ventilators were able to avoid PVA in high-level leak conditions. However, asynchrony appeared in cases of abnormal mechanical properties of respiratory system or closed UA. In case of closed UA, the EPAP should be adjusted prior to the inspiratory trigger. Not applicable.

  11. Assessment of dynamic mechanical properties of the respiratory system during high-frequency oscillatory ventilation*.

    Dellacà, Raffaele L; Zannin, Emanuela; Ventura, Maria L; Sancini, Giulio; Pedotti, Antonio; Tagliabue, Paolo; Miserocchi, Giuseppe

    2013-11-01

    1) To investigate the possibility of estimating respiratory system impedance (Zrs, forced oscillation technique) by using high-amplitude pressure oscillations delivered during high-frequency oscillatory ventilation; 2) to characterize the relationship between Zrs and continuous distending pressure during an increasing/decreasing continuous distending pressure trial; 3) to evaluate how the optimal continuous distending pressure identified by Zrs relates to the point of maximal curvature of the deflation limb of the quasi-static pressure-volume curve. Prospective laboratory animal investigation. Experimental medicine laboratory. Eight New Zealand rabbits. The rabbits were ventilated with high-frequency oscillatory ventilation. Zrs was measured while continuous distending pressure was increased and decreased between 2 and 26 cm H2O in 1-minute steps of 4 cm H2O. At each step, a low-amplitude (6 cm H2O) sinusoidal signal was alternated with a high-amplitude (18 cm H2O) asymmetric high-frequency oscillatory ventilation square pressure waveform. Pressure-volume curves were determined at the end of the continuous distending pressure trial. All measurements were repeated after bronchoalveolar lavage. Zrs was estimated from flow and pressure measured at the inlet of the tracheal tube and expressed as resistance (Rrs) and reactance (Xrs). Linear correlation between the values, measured by applying the small-amplitude sinusoidal signal and the ventilator waveform, was good for Xrs (r = 0.95 ± 0.04) but not for Rrs (r = 0.60 ± 0.34). Following lavage, the Xrs-continuous distending pressure curves presented a maximum on the deflation limb, identifying an optimal continuous distending pressure that was, on average, 1.1 ± 1.7 cm H2O below the point of maximal curvature of the deflation limb of the pressure-volume curves. Xrs can be accurately measured during high-frequency oscillatory ventilation without interrupting ventilation and/or connecting additional devices. An optimal

  12. Feeding behavior as an early predictor of bovine respiratory disease in North American feedlot systems.

    Wolfger, B; Schwartzkopf-Genswein, K S; Barkema, H W; Pajor, E A; Levy, M; Orsel, K

    2015-01-01

    Bovine respiratory disease (BRD), which can cause substantial losses for feedlot operations, is often difficult to detect based solely on visual observations. The objectives of the current study were to determine a BRD case identification based on clinical and laboratory parameters and assess the value of feeding behavior for early detection of BRD. Auction-derived, mixed-breed beef steers (n = 213) with an average arrival weight of 294 kg were placed at a southern Alberta commercial feedlot equipped with an automated feed bunk monitoring system. Feeding behavior was recorded continuously (1-s intervals) for 5 wk after arrival and summarized into meals. Meals were defined as feeding events that were interrupted by less than 300 s nonfeeding. Meal intake (g) and meal time (min) were further summarized into daily mean, minimum, maximum, and sum and, together with frequency of meals per day, were fit into a discrete survival time analysis with a conditional log-log link. Feedlot staff visually evaluated (pen-checked) health status twice daily. Within 35 d after arrival, 76% (n = 165) of the steers had 1 or more clinical signs of BRD (reluctance to move, crusted nose, nasal or ocular discharge, drooped ears or head, and gaunt appearance). Whereas 41 blood samples could not be processed due to immediate freezing, for 124 of these steers, complete and differential blood cell count, total serum protein, plasma fibrinogen, serum concentration of haptoglobin (HP), and serum amyloid A (SAA) were determined. The disease definition for BRD was a rectal temperature ≥ 40.0°C, at least 2 clinical signs of BRD, and HP > 0.15 mg/mL. It was noteworthy that 94% of the 124 steers identified by the feedlot staff with clinical signs of BRD had HP > 0.15 mg/mL. An increase in mean meal intake, frequency, and mean inter-meal interval was associated with a decreased hazard for developing BRD 7 d before visual identification (P increased mean mealtime, frequency, and mean inter

  13. Overview and sample applications of SMILES and Odin-SMR retrievals of upper tropospheric humidity and cloud ice mass

    P. Eriksson

    2014-12-01

    Full Text Available Retrievals of cloud ice mass and humidity from the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES and the Odin-SMR (Sub-Millimetre Radiometer limb sounder are presented and example applications of the data are given. SMILES data give an unprecedented view of the diurnal variation of cloud ice mass. Mean regional diurnal cycles are reported and compared to some global climate models. Some improvements in the models regarding diurnal timing and relative amplitude were noted, but the models' mean ice mass around 250 hPa is still low compared to the observations. The influence of the ENSO (El Niño–Southern Oscillation state on the upper troposphere is demonstrated using 12 years of Odin-SMR data. The same retrieval scheme is applied for both sensors, and gives low systematic differences between the two data sets. A special feature of this Bayesian retrieval scheme, of Monte Carlo integration type, is that values are produced for all measurements but for some atmospheric states retrieved values only reflect a priori assumptions. However, this "all-weather" capability allows a direct statistical comparison to model data, in contrast to many other satellite data sets. Another strength of the retrievals is the detailed treatment of "beam filling" that otherwise would cause large systematic biases for these passive cloud ice mass retrievals. The main retrieval inputs are spectra around 635/525 GHz from tangent altitudes below 8/9 km for SMILES/Odin-SMR, respectively. For both sensors, the data cover the upper troposphere between 30° S and 30° N. Humidity is reported as both relative humidity and volume mixing ratio. The vertical coverage of SMILES is restricted to a single layer, while Odin-SMR gives some profiling capability between 300 and 150 hPa. Ice mass is given as the partial ice water path above 260 hPa, but for Odin-SMR ice water content, estimates are also provided. Besides a smaller contrast between most dry and wet

  14. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  15. Respiratory mechanics

    Wilson, Theodore A

    2016-01-01

    This book thoroughly covers each subfield of respiratory mechanics: pulmonary mechanics, the respiratory pump, and flow. It presents the current understanding of the field and serves as a guide to the scientific literature from the golden age of respiratory mechanics, 1960 - 2010. Specific topics covered include the contributions of surface tension and tissue forces to lung recoil, the gravitational deformation of the lung, and the interdependence forces that act on pulmonary airways and blood vessels. The geometry and kinematics of the ribs is also covered in detail, as well as the respiratory action of the external and internal intercostal muscles, the mechanics of the diaphragm, and the quantitative compartmental models of the chest wall is also described. Additionally, flow in the airways is covered thoroughly, including the wave-speed and viscous expiratory flow-limiting mechanisms; convection, diffusion and the stationary front; and the distribution of ventilation. This is an ideal book for respiratory ...

  16. A Two-Dimensional Human Minilung System (Model for Respiratory Syncytial Virus Infections

    Esmeralda Magro-Lopez

    2017-12-01

    Full Text Available Human respiratory syncytial virus (HRSV is a major cause of serious pediatric respiratory diseases that lacks effective vaccine or specific therapeutics. Although our understanding about HRSV biology has dramatically increased during the last decades, the need for adequate models of HRSV infection is compelling. We have generated a two-dimensional minilung from human embryonic stem cells (hESCs. The differentiation protocol yielded at least six types of lung and airway cells, although it is biased toward the generation of distal cells. We show evidence of HRSV replication in lung cells, and the induction of innate and proinflammatory responses, thus supporting its use as a model for the study of HRSV–host interactions.

  17. Using real options to evaluate the flexibility in the deployment of SMR

    Locatelli, G. [Univ. of Lincoln, Lincoln School of Engineering, Brayford Pool, Lincoln LN6 7TS (United Kingdom); Mancini, M. [Politecnico di Milano, Dept. of Management, Economics and Industrial Engineering, Via Lambruschini 4/B, Milano (Italy); Ruiz, F.; Solana, P. [Universidad Politecnica de Madrid, Dep. de Ingenieria de Organizacion, Administracion de Empresas y Estadistica, C/ Jose Gutierrez Abascal, 2, 28006-Madrid (Spain)

    2012-07-01

    According to recent estimations the financial gap between Large Reactors (LR) and Small Medium Reactors (SMRs) seems not as huge as the economy of scale would suggest, so the SMRs are going to be important players of the worldwide nuclear renaissance. POLIMIs INCAS model has been developed to compare the investment in SMR with respect to LR. It provides the value of IRR (Internal Rate of Return), NPV (Net Present Value), LUEC (Levelized Unitary Electricity Cost), up-front investment, etc. The aim of this research is to integrate the actual INCAS model, based on discounted cash flows, with the real option theory to measure flexibility of the investor to expand, defer or abandon a nuclear project, under future uncertainties. The work compares the investment in a large nuclear power plant with a series of smaller, modular nuclear power plants on the same site. As a consequence it compares the benefits of the large power plant, coming from the economy of scale, to the benefit of the modular project (flexibility) concluding that managerial flexibility can be measured and used by an investor to face the investment risks. (authors)

  18. Using real options to evaluate the flexibility in the deployment of SMR

    Locatelli, G.; Mancini, M.; Ruiz, F.; Solana, P.

    2012-01-01

    According to recent estimations the financial gap between Large Reactors (LR) and Small Medium Reactors (SMRs) seems not as huge as the economy of scale would suggest, so the SMRs are going to be important players of the worldwide nuclear renaissance. POLIMIs INCAS model has been developed to compare the investment in SMR with respect to LR. It provides the value of IRR (Internal Rate of Return), NPV (Net Present Value), LUEC (Levelized Unitary Electricity Cost), up-front investment, etc. The aim of this research is to integrate the actual INCAS model, based on discounted cash flows, with the real option theory to measure flexibility of the investor to expand, defer or abandon a nuclear project, under future uncertainties. The work compares the investment in a large nuclear power plant with a series of smaller, modular nuclear power plants on the same site. As a consequence it compares the benefits of the large power plant, coming from the economy of scale, to the benefit of the modular project (flexibility) concluding that managerial flexibility can be measured and used by an investor to face the investment risks. (authors)

  19. SU-F-J-129: Verification of Geometric and Dosimetric Accuracy of Respiratory Management Systems Using Homemade Phantom

    Goksel, E; Kucucuk, H; Senkesen, O [Acibadem Kozyatgi Hospital, Istanbul (Turkey); Tezcanli, E [Acibadem University, Istanbul (Turkey)

    2016-06-15

    Purpose: Different placements of Infrared Cameras (IRC) in CT and treatment rooms can cause gating window level (GWL) variations leading to differences between GWL used for planning and treatments. Although, Varian Clinac DHX-OBI sytem and CT are equipped with the same kind of IRC, Truebeam STx (TB) has a different type of IRC known as banana type. In this study; geometric and dosimetric accuracy of respiratory management system (RPM) for different machines were investigated with a special homemade phantom. Methods: Special phantom was placed on the respiratory simulator machine and a CT data set was obtained at the end of the expirium phase (EOE). Conformal and IMRT plans were generated on the EOE CT image series for both DHX-OBI and TB LINACs while a VMAT plan was generated only for TB.The acquired respiratory graphs in the CT were directly sent to DHX-OBI system, and they were converted with software before sending to TB. EBT3 films were placed inside the phantom and were irradiated using RPM system with two machines for different plans. Planar dose distributions were compared with gamma analysis (GA) method (3mm, %3) to evaluate planned-measured dose differences. In addition, radio-opac marker was placed in the center of the phantom to evaluate the geometric accuracy of treatment field with gated flouroscopy (GF). Results: There were no shifts detected between planning and treeatment GWL for both DHX-OBI and TB. Difference on the GF image between digital graticule and radio-opac marker was <1mm for TB and 1mm for DHX-OBI. Although, GA agreement was 97% for conformal and IMRT techniques in TB, it was 96% for VMAT technique. While GA agreement was 98% for conformal technique in DHX-OBI, IMRT was 95%.ConclusionThis study showed that RPM can be used accurately in spite of different IRC placements or different types of ICR used.

  20. Reassessment of the evidence for postcranial skeletal pneumaticity in Triassic archosaurs, and the early evolution of the avian respiratory system.

    Richard J Butler

    Full Text Available Uniquely among extant vertebrates, birds possess complex respiratory systems characterised by the combination of small, rigid lungs, extensive pulmonary air sacs that possess diverticula that invade (pneumatise the postcranial skeleton, unidirectional ventilation of the lungs, and efficient crosscurrent gas exchange. Crocodilians, the only other living archosaurs, also possess unidirectional lung ventilation, but lack true air sacs and postcranial skeletal pneumaticity (PSP. PSP can be used to infer the presence of avian-like pulmonary air sacs in several extinct archosaur clades (non-avian theropod dinosaurs, sauropod dinosaurs and pterosaurs. However, the evolution of respiratory systems in other archosaurs, especially in the lineage leading to crocodilians, is poorly documented. Here, we use µCT-scanning to investigate the vertebral anatomy of Triassic archosaur taxa, from both the avian and crocodilian lineages as well as non-archosaurian diapsid outgroups. Our results confirm previous suggestions that unambiguous evidence of PSP (presence of internal pneumatic cavities linked to the exterior by foramina is found only in bird-line (ornithodiran archosaurs. We propose that pulmonary air sacs were present in the common ancestor of Ornithodira and may have been subsequently lost or reduced in some members of the clade (notably in ornithischian dinosaurs. The development of these avian-like respiratory features might have been linked to inferred increases in activity levels among ornithodirans. By contrast, no crocodile-line archosaur (pseudosuchian exhibits evidence for unambiguous PSP, but many of these taxa possess the complex array of vertebral laminae and fossae that always accompany the presence of air sacs in ornithodirans. These laminae and fossae are likely homologous with those in ornithodirans, which suggests the need for further investigation of the hypothesis that a reduced, or non-invasive, system of pulmonary air sacs may be have

  1. Obesity and respiratory diseases

    Zammit, Christopher; Liddicoat, Helen; Moonsie, Ian; Makker, Himender

    2010-01-01

    Christopher Zammit, Helen Liddicoat, Ian Moonsie, Himender MakkerSleep and Ventilation Unit, Department of Respiratory Medicine, North Middlesex University Hospital, London, UKAbstract: The obesity epidemic is a global problem, which is set to increase over time. However, the effects of obesity on the respiratory system are often underappreciated. In this review, we will discuss the mechanical effects of obesity on lung physiology and the function of adipose tissue as an endocrine organ produ...

  2. Effects of Asian sand dust particles on the respiratory and immune system.

    Honda, Akiko; Matsuda, Yugo; Murayama, Rumiko; Tsuji, Kenshi; Nishikawa, Masataka; Koike, Eiko; Yoshida, Seiichi; Ichinose, Takamichi; Takano, Hirohisa

    2013-01-01

    Epidemiologic studies have reported that Asian sand dust (ASD) particles can affect respiratory health; however, the mechanisms remain unclear. We investigated the effects of ASD on airway epithelial cells and immune cells, and their contributing factors to the effects. Human airway epithelial cells were exposed to ASD collected on 1-3 May (ASD1) and on 12-14 May (ASD2) 2011 in Japan and heat-treated ASD1 for excluding heat-sensitive substances (H-ASD) at a concentration of 0, 3, 30 or 90 µg ...

  3. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion.

    Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Pelosi, Paolo; Silva, Pedro L; de Abreu, Marcelo Gama; Rocco, Patricia R M

    2017-01-01

    Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV ( n = 6/group) [tidal volume (V T ) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH 2 O, fraction of inspired oxygen (FiO 2 ) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated V T values ( n = 1200; mean V T = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH 2 0/ml and 2.0 ± 0.8 cmH 2 0/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9-33.1] and VV 5.4% [3.1-8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and

  4. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion

    Patricia R. M. Rocco

    2017-05-01

    Full Text Available Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1 ischemia-reperfusion (IR, in which the left pulmonary hilum was completely occluded and released after 30 min; and (2 Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured and right (contralateral lungs from 6 animals per group were removed, and served as non-ventilated group (NV for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group [tidal volume (VT = 6 mL/kg, positive end-expiratory pressure (PEEP = 2 cmH2O, fraction of inspired oxygen (FiO2 = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg, with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final, respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively. In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular

  5. Long Term Effects of Tear Gases on Respiratory System: Analysis of 93 Cases

    Peri Arbak

    2014-01-01

    Full Text Available Aim. This study aimed to assess the long-term respiratory effects of tear gases among the subjects with history of frequent exposure. Materials and Methods. A questionnaire by NIOSH and pulmonary function tests was performed in 93 males exposed to the tear gases frequently and 55 nonexposed subjects. Results. The mean numbers of total exposure and last 2 years exposure were 8.4±6.4 times, 5.6±5.8 times, respectively. Tear gas exposed subjects were presented with a higher rate for cough and phlegm more than 3 months (24.7% versus 11.3%, P>0.05. Mean FEV1/FVC and % predicted MMFR in smoker exposed subjects are significantly lower than those in smoker controls (81.7% versus 84.1%, P=0.046 and 89.9% versus 109.6%, P=0.0004, resp.. % predicted MMFR in nonsmoker exposed subjects is significantly lower than that in nonsmoker controls (99.4% versus 113.1%, P=0.05. Odds ratios for chest tightness, exercise dyspnea, dyspnea on level ground, winter morning cough, phlegm, and daily phlegm were increased almost 2 to 2.5 folds among tear gas exposed subjects. Conclusion. The rates for respiratory complaints were high in the case of the exposure to the tear gases previously. Tears gas exposed subjects were found to be under the risk for chronic bronchitis.

  6. Diagnosis and epidemiology of respiratory system diseases due to plant dusts

    Goscicki, J.W.; Indulski, J.A.

    1981-01-01

    Of the respiratory tract diseases - byssinosis - i.e. the disease diagnosed in textile industry workers has aroused interest and controversies for many years. In Western Europe Countries the USA, Egypt and Pakistan this disease was diagnosed in more than half of the workers employed at cotton processing. Epidemiological data imply that in Eastern and Middle Europe few authors diagnose byssinosis in the population exposed to vegetable dusts. In the Soviet Union, the greatest cotton producer in the world, processing the greatest amounts of this raw material in the textile industry, medical examinations carried out in different centres did not show byssinosis symptoms in textile workers, that would apply to Schilling's criteria. Vegetable dusts inherent in agricultural and food industry largely promote the occurrence of nonspecific respiratory tract diseases. They are diagnosed as chronic bronchitis, which at dusted workstations are the mean cause of sickness absenteeism. The preventive activities aimed at the reduction of hazardous effects of dust upon organism would consist mostly in application of technical measures, i.e. technological processes hermetization and ventilation and only in scarce cases - in the use of good antidust personal protective measures.

  7. Smoking status in parents of children hospitalized with a diagnosis of respiratory system disorders

    Nursan Cinar

    2010-11-01

    Full Text Available The purpose of this study was to investigate the relationship between the statuses of hospitalized children with diagnosis of respiratory tract disease with cigarette use in the parents. This descriptive study was conducted in a Gowerment Hospital in the Sakarya city center in Turkey between June 2007 and June 2008. The inclusion criterion was willingness of families with children hospitalized due to diagnosis of respiratory disease to particípate in the study. Data were collected from 345 parents using the questionnaire prepared by researchers. In our study parental smoking was observed in 42.3% of fathers, 7.8% mothers and for 20.9% both parents were smoking. It was found that the hospitalization rates were more than two times higher in children diagnosed with pneumonia and bronchitis and three times higher in children hospitalized for asthma whose parents smoke at home compared to those whose parents are non-smokers. Health care professionals who take care of children need to discuss the harmful effects of smoking and the importance of reducing childhood exposure to secondhand smoke; parents should be educated and encouraged not to smoke.

  8. Adaptive SLICE method: an enhanced method to determine nonlinear dynamic respiratory system mechanics

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    The objective of this paper is to introduce and evaluate the adaptive SLICE method (ASM) for continuous determination of intratidal nonlinear dynamic compliance and resistance. The tidal volume is subdivided into a series of volume intervals called slices. For each slice, one compliance and one resistance are calculated by applying a least-squares-fit method. The volume window (width) covered by each slice is determined based on the confidence interval of the parameter estimation. The method was compared to the original SLICE method and evaluated using simulation and animal data. The ASM was also challenged with separate analysis of dynamic compliance during inspiration. If the signal-to-noise ratio (SNR) in the respiratory data decreased from +∞ to 10 dB, the relative errors of compliance increased from 0.1% to 22% for the ASM and from 0.2% to 227% for the SLICE method. Fewer differences were found in resistance. When the SNR was larger than 40 dB, the ASM delivered over 40 parameter estimates (42.2 ± 1.3). When analyzing the compliance during inspiration separately, the estimates calculated with the ASM were more stable. The adaptive determination of slice bounds results in consistent and reliable parameter values. Online analysis of nonlinear respiratory mechanics will profit from such an adaptive selection of interval size. (paper)

  9. Approaches to systems biology. Four methods to study single-cell gene expression, cell motility, antibody reactivity, and respiratory metabolism

    Hagedorn, Peter

    To understand how complex systems, such as cells, function, comprehensive Measurements of their constituent parts must be made. This can be achieved by combining methods that are each optimized to measure specific parts of the system. Four such methods,each covering a different area, are presented...... from such measurements allows models of the system to be developed and tested. For each of the methods, such analysis and modelling approaches have beenapplied and are presented: Differentially regulated genes are identified and classified according to function; cell-specfic motility models...... are developed that can distinguish between different surfaces; a method for selecting repertoires of antigens thatseparate mice based on their response to treatment is developed; and the observed concentrations of free and bound NADH is used to build and test a basic model of respiratory metabolism...

  10. Respiratory system model for quasistatic pulmonary pressure-volume (P-V) curve: inflation-deflation loop analyses.

    Amini, R; Narusawa, U

    2008-06-01

    A respiratory system model (RSM) is developed for the deflation process of a quasistatic pressure-volume (P-V) curve, following the model for the inflation process reported earlier. In the RSM of both the inflation and the deflation limb, a respiratory system consists of a large population of basic alveolar elements, each consisting of a piston-spring-cylinder subsystem. A normal distribution of the basic elements is derived from Boltzmann statistical model with the alveolar closing (opening) pressure as the distribution parameter for the deflation (inflation) process. An error minimization by the method of least squares applied to existing P-V loop data from two different data sources confirms that a simultaneous inflation-deflation analysis is required for an accurate determination of RSM parameters. Commonly used terms such as lower inflection point, upper inflection point, and compliance are examined based on the P-V equations, on the distribution function, as well as on the geometric and physical properties of the basic alveolar element.

  11. New insight into the evolution of the vertebrate respiratory system and the discovery of unidirectional airflow in iguana lungs.

    Cieri, Robert L; Craven, Brent A; Schachner, Emma R; Farmer, C G

    2014-12-02

    The generally accepted framework for the evolution of a key feature of the avian respiratory system, unidirectional airflow, is that it is an adaptation for efficiency of gas exchange and expanded aerobic capacities, and therefore it has historically been viewed as important to the ability of birds to fly and to maintain an endothermic metabolism. This pattern of flow has been presumed to arise from specific features of the respiratory system, such as an enclosed intrapulmonary bronchus and parabronchi. Here we show unidirectional airflow in the green iguana, a lizard with a strikingly different natural history from that of birds and lacking these anatomical features. This discovery indicates a paradigm shift is needed. The selective drivers of the trait, its date of origin, and the fundamental aerodynamic mechanisms by which unidirectional flow arises must be reassessed to be congruent with the natural history of this lineage. Unidirectional flow may serve functions other than expanded aerobic capacity; it may have been present in the ancestral diapsid; and it can occur in structurally simple lungs.

  12. Technical Note: A respiratory monitoring and processing system based on computer vision: prototype and proof of principle.

    Leduc, Nicolas; Atallah, Vincent; Escarmant, Patrick; Vinh-Hung, Vincent

    2016-09-08

    Monitoring and controlling respiratory motion is a challenge for the accuracy and safety of therapeutic irradiation of thoracic tumors. Various commercial systems based on the monitoring of internal or external surrogates have been developed but remain costly. In this article we describe and validate Madibreast, an in-house-made respiratory monitoring and processing device based on optical tracking of external markers. We designed an optical apparatus to ensure real-time submillimetric image resolution at 4 m. Using OpenCv libraries, we optically tracked high-contrast markers set on patients' breasts. Validation of spatial and time accuracy was performed on a mechanical phantom and on human breast. Madibreast was able to track motion of markers up to a 5 cm/s speed, at a frame rate of 30 fps, with submillimetric accuracy on mechanical phantom and human breasts. Latency was below 100 ms. Concomitant monitoring of three different locations on the breast showed discrepancies in axial motion up to 4 mm for deep-breathing patterns. This low-cost, computer-vision system for real-time motion monitoring of the irradiation of breast cancer patients showed submillimetric accuracy and acceptable latency. It allowed the authors to highlight differences in surface motion that may be correlated to tumor motion.v. © 2016 The Authors.

  13. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method

    Schumann, Stefan; Burcza, Boris; Guttmann, Josef; Haberthür, Christoph; Lichtwarck-Aschoff, Michael

    2009-01-01

    In the clinical situation and in most research work, the analysis of respiratory system mechanics is limited to the estimation of single-value compliances during static or quasi-static conditions. In contrast, our SLICE method analyses intratidal nonlinearity under the dynamic conditions of mechanical ventilation by calculating compliance and resistance for six conjoined volume portions (slices) of the pressure–volume loop by multiple linear regression analysis. With the gliding-SLICE method we present a new approach to determine continuous intratidal nonlinear compliance. The performance of the gliding-SLICE method was tested both in computer simulations and in a physical model of the lung, both simulating different intratidal compliance profiles. Compared to the original SLICE method, the gliding-SLICE method resulted in smaller errors when calculating the compliance or pressure course (all p 2 O s L −1 to 0.8 ± 0.3 cmH 2 O s L −1 (mathematical model) and from 7.2 ± 3.9 cmH 2 O s L −1 to 0.4 ± 0.2 cmH 2 O s L −1 (physical model) (all p < 0.001). We conclude that the new gliding-SLICE method allows detailed assessment of intratidal nonlinear respiratory system mechanics without discontinuity error

  14. Stable Water Isotopologues in the Stratosphere Retrieved from Odin/SMR Measurements

    Tongmei Wang

    2018-01-01

    Full Text Available Stable Water Isotopologues (SWIs are important diagnostic tracers for understanding processes in the atmosphere and the global hydrological cycle. Using eight years (2002–2009 of retrievals from Odin/SMR (Sub-Millimetre Radiometer, the global climatological features of three SWIs, H216O, HDO and H218O, the isotopic composition δD and δ18O in the stratosphere are analysed for the first time. Spatially, SWIs are found to increase with altitude due to stratospheric methane oxidation. In the tropics, highly depleted SWIs in the lower stratosphere indicate the effect of dehydration when the air comes through the cold tropopause, while, at higher latitudes, more enriched SWIs in the upper stratosphere during summer are produced and transported to the other hemisphere via the Brewer–Dobson circulation. Furthermore, we found that more H216O is produced over summer Northern Hemisphere and more HDO is produced over summer Southern Hemisphere. Temporally, a tape recorder in H216O is observed in the lower tropical stratosphere, in addition to a pronounced downward propagating seasonal signal in SWIs from the upper to the lower stratosphere over the polar regions. These observed features in SWIs are further compared to SWI-enabled model outputs. This helped to identify possible causes of model deficiencies in reproducing main stratospheric features. For instance, choosing a better advection scheme and including methane oxidation process in a specific model immediately capture the main features of stratospheric water vapor. The representation of other features, such as the observed inter-hemispheric difference of isotopic component, is also discussed.

  15. Analysis of Cigarette Smoke Deposition Within an In Vitro Exposure System for Simulating Exposure in the Human Respiratory Tract

    Ishikawa Shinkichi

    2016-01-01

    Full Text Available For the risk assessment of airborne chemicals, a variety of in vitro direct exposure systems have been developed to replicate airborne chemical exposure in vivo. Since cells at the air-liquid interface are exposed to cigarette smoke as an aerosol in direct exposure systems, it is possible to reproduce the situation of cigarette smoke exposure in the human respiratory system using this device. However it is difficult to know whether the exposed cigarette smoke in this system is consistent with the smoke retained in the human respiratory tract. The purpose of this study is to clarify this point using the CULTEX® RFS module which is a recently developed direct exposure system. For this purpose, solanesol and acetaldehyde were respectively chosen as the particulate and gas/vapor phase representatives of smoke constituents, and their deposition and balance per unit area of cell culture surface of the RFS module were measured (dosimetry. We also conducted human retention studies to compare with the dosimetry data. By comparing inhaled smoke and exhaled smoke under three inhalation conditions, we estimated the regional retention and balance of each representative per unit surface area of the respiratory tract (mouth, bronchi, and alveoli separately. The deposition of solanesol and acetaldehyde per unit area of cell culture surface in the RFS module decreased dependent on the dilution flow rate and ranged from 0.26-0.0076%/cm2 in our experimental conditions. The ratio of deposited acetaldehyde to deposited solanesol ranged from 0.96-1.96 in the RFS module. The retention of solanesol and acetaldehyde per unit surface area in the mouth and the bronchi ranged from 0.095-0.0083%/cm2 in this study. The retention per unit surface area of alveoli was far lower than in the other two regions (0.0000063%/cm2. The ratio of retained acetaldehyde to retained solanesol ranged from 0.54-1.97. From these results, we concluded that the CULTEX® RFS module can simulate

  16. Prenatal and neonatal adaptations with a focus on the respiratory system.

    Vannucchi, C I; Silva, L C G; Lúcio, C F; Regazzi, F M; Veiga, G A L; Angrimani, D S

    2012-12-01

    Among the modifications that occur during the neonatal period, pulmonary development is the most critical. The neonate's lungs must be able to perform adequate gas exchange, which was previously accomplished by the placenta. Neonatal respiratory distress syndrome is defined as insufficient surfactant production or pulmonary structural immaturity and is specifically relevant to preterm newborns. Prenatal maternal betamethasone treatment of bitches at 55 days of gestation leads to structural changes in the neonatal lung parenchyma and consequently an improvement in the preterm neonatal respiratory condition, but not to an increase in pulmonary surfactant production. Parturition represents an important challenge to neonatal adaptation, as the uterine and abdominal contractions during labour provoke intermittent hypoxia. Immediately after birth, puppies present venous mixed acidosis (low blood pH and high dioxide carbon saturation) and low but satisfactory Apgar scores. Thus, the combination of physiological hypoxia during birth and the initial effort of filling the pulmonary alveoli with oxygen results in anaerobiosis. As a neonatal adaptation follow-up, the Apgar analysis indicates a tachypnoea response after 1 h of life, which leads to a shift in the blood acid-base status to metabolic acidosis. One hour is sufficient for canine neonates to achieve an ideal Apgar score; however, a haemogasometric imbalance persists. Dystocia promotes a long-lasting bradycardia effect, slows down Apgar score progression and aggravates metabolic acidosis and stress. The latest data reinforce the need to accurately intervene during canine parturition and offer adequate medical treatment to puppies that underwent a pathological labour. © 2012 Blackwell Verlag GmbH.

  17. A linear, time-varying simulation of the respiratory tract system

    Hernandez, O.

    1992-11-01

    These results show that regional deposition efficiencies of inhaled particles are highly dependent on the level of physical activity in all the spectrum of thermodynamic and aerodynamic aerosol particle sizes; also it was shown that for particles in the aerodynamic size range, the values of regional deposition efficiencies at the inner regions of the lung are highly dependent on age. In addition, the shape of regional deposition efficiency curves as a function of particle size have a similar behavior for all ages; thus, any variation of the airway geometry and respiratory physiological parameters such as tidal volumes and breathing frequencies due to age difference do not cause a change in the fundamental mechanisms of deposition. Thus, for all the cases of physical activity and age dependency, the deposition of ultrafine aerosol particles is highly enhanced by diffusive processes in all regions of the respiratory tract, and for very large aerosol size particles this behavior is repeated again due to impaction and sedimentation mechanisms. Although the results presented at this work, are the result of computer simulations based on different sources of experimental data, the structure of the computer simulation code BIODEP is flexible enough to the acquisition of any kind of new experimental information in terms of biokinetic analysis and regional deposition parameters. In addition, since the design of BIODEP was intended for easy access to the users, then with exception of the subroutine DIVPAG, at this moment, the modular design of BIODEP using FORTRAN 77 allows the implementation of all the subroutines of BIODEP to be used in a interactive mode with any microcomputer.

  18. Impact of obstructive sleep apnea on lung volumes and mechanical properties of the respiratory system in overweight and obese individuals.

    Abdeyrim, Arikin; Zhang, Yongping; Li, Nanfang; Zhao, Minghua; Wang, Yinchun; Yao, Xiaoguang; Keyoumu, Youledusi; Yin, Ting

    2015-07-25

    Even through narrowing of the upper-airway plays an important role in the generation of obstructive sleep apnea (OSA), the peripheral airways is implicated in pre-obese and obese OSA patients, as a result of decreased lung volume and increased lung elastic recoil pressure, which, in turn, may aggravate upper-airway collapsibility. A total of 263 male (n = 193) and female (n = 70) subjects who were obese to various degrees without a history of lung diseases and an expiratory flow limitation, but troubled with snoring or suspicion of OSA were included in this cross-sectional study. According to nocturnal-polysomnography the subjects were distributed into OSA and non-OSA groups, and were further sub-grouped by gender because of differences between males and females, in term of, lung volume size, airway resistance, and the prevalence of OSA among genders. Lung volume and respiratory mechanical properties at different-frequencies were evaluated by plethysmograph and an impulse oscillation system, respectively. Functional residual capacity (FRC) and expiratory reserve volume were significantly decreased in the OSA group compared to the non-OSA group among males and females. As weight and BMI in males in the OSA group were greater than in the non-OSA group (90 ± 14.8 kg vs. 82 ± 10.4 kg, p volumes decreases were independent from BMI and associated with the severity of OSA. This result was further confirmed by the female cohort. Significant increases in total respiratory resistance and decreases in respiratory conductance (Grs) were observed with increasing severity of OSA, as defined by the apnea-hypopnea index (AHI) in both genders. The specific Grs (sGrs) stayed relatively constant between the two groups in woman, and there was only a weak association between AHI and sGrs among man. Multiple-stepwise-regression showed that reactance at 5 Hz was highly correlated with AHI in males and females or hypopnea index in females, independently

  19. Dotriacontane-16,17-14C distribution pattern in the respiratory system of two hamster species after passive exposure to radioactive labelled smoke

    Kmoch, N.; Mohr, U.

    1974-01-01

    The quantitative and qualitative distribution of 14 C labeled dotriacontane (DOT- 14 C) determined by liquid scintillation counting and autoradiography in the respiratory system, the digestive tract, liver and kidneys of Syrian golden and European hamsters, males and females, is described after they had been exposed to radioactive labeled cigarette smoke. The different DOT- 14 C distributions are discussed in detail with special attention given to the respiratory tract, related species differences and the topographic subdivisions of apex nasi, fundus nasi, pharynx, larynx, trachea, and lungs. It is apparent that the absolute amount of activity in the respiratory tract related to body size of the Syrian golden hamster is greater than in the European hamster but that the percentual distribution exhibits a greater filtering action of the upper respiratory tract of Syrian golden hamster than of the European hamster so that a larger percentual amount of total inhaled particulate matter reaches the lungs. The European hamster might be a more useful model for the investigation of respiratory tract carcinogenesis due to the possibility of a longer life time exposure and a higher sensitivity to respiratory tract carcinogens

  20. Investigations of the Cardiovascular and Respiratory Systems on Board the International Space Station: Experiments Puls and Pneumocard

    Baranov, V. M.; Baevsky, R. M.; Drescher, J.; Tank, J.

    parameters describing the results of the function of these systems like heart rate, arterial pressure, cardiac output, or breathing frequency, concentration of O2 and CO2 , etc. Missing significant changes of these parameters during weightlessness supports the hypothesis that adaptational and compensatory mechanisms are sufficient and guarantee cardiovascular homeostasis under changing environmental conditions. characteristic changes of the vegetative balance and of the activity of different regulatory elements at the brainstem and subcortical level. This changes guaranteed the adaptation to long term weightlessness. However, it remains unclear to what extent the different levels are involved. Moreover, the criteria describing the efficacy of cardiorespiratory interaction for the different functional states are not defined yet. The investigation of this problems is highly relevant in order to improve the medical control, especially if considering that the disruption of regulatory systems mostly precedes dangerous destruction of homeostasis. cardiovascular and respiratory function on Board the International Space Station (ISS) aiming to obtain new insights into the interaction between different regulatory elements. "Puls" is measures ECG, photoplethysmogram (PPG), and the pneumotachogram (PTG). The ECG is used to measure time series of R-R intervals and to analyse HRV. PPG is used to define the pulse wave velocity, phases of the cardiac cycle, and an estimate of the filling of finger vessels. The variability of these parameters is also calculated and compared to HRV. The analysis of the PTG allows to describe the interaction of the regulatory parameters of the cardiovascular and respiratory systems. Hence, an important feature of the experiment "Puls" is the investigation of regulatory mechanisms rather than of cardiovascular homeostasis. cardiography) and left ventricular contractility (seismocardiography) will be obtained. This expansion is of major importance

  1. The Effects of Leucine, Zinc, and Chromium Supplements on Inflammatory Events of the Respiratory System in Type 2 Diabetic Rats.

    Saeed Kolahian

    Full Text Available Diabetes mellitus is a major cause of serious micro- and macrovascular diseases that affect nearly every system in the body, including the respiratory system. Non-enzymatic protein glycation due to hyperglycaemic stress has fundamental implications due to the large capillary network and amount of connective tissue in the lung. The current study was designed to determine whether leucine, zinc, and chromium supplementations influence the function and histological structure of the respiratory tract in a rat model of type 2 diabetes. Seventy-seven rats were divided into eleven groups, consisting of 7 animals each. One group served as negative control and insulin and glibenclamide were used as positive control drugs. Thus, eight groups received the nutritional supplements alone or in combination with each other. Nutritional supplements and glibenclamide were added to the drinking water and neutral protamine Hagedorn insulin was subcutaneously injected during the 4 weeks of treatment period. The induction of type 2 diabetes in the rats caused an infiltration of mononuclear cells and edema in the submucosa of the trachea and lung, severe fibrosis around the vessels and airways, and perivascular and peribronchial infiltration of inflammatory cells and fibrin. In the diabetic group, the total inflammation score and Reid index significantly increased. Diabetes induction significantly reduced the total antioxidant status and elevated the lipid peroxidation products in the serum, lung lavage and lung tissue of the diabetic animals. Treatment with nutritional supplements significantly decreased the histopathological changes and inflammatory indices in the diabetic animals. Supplementation of diabetic rats with leucine, zinc, and chromium, alone and in combination, significantly increased the total antioxidant status and lipid peroxidation level in the diabetic animals. The nutritional supplements improved the enzymatic antioxidant activity of catalase

  2. Clinical characteristics of the respiratory and cardiovascular systems in patients with combination of chronic obstructive pulmonary disease and heart failure

    I. I. Vyshnyvetskyy

    2017-06-01

    Full Text Available The aim of our work was to assess the respiratory and cardiovascular systems of patients with a combination of chronic obstructive pulmonary disease (COPD and congestive heart failure (CHF. Materials and methods. The study included 177 patients who had been diagnosed COPD by criteria GOLD. CHF was diagnosed in 77 (43.5 % cases – 29 (16.4 % with reduced systolic function and 48 (27.1 % with preserved systolic function. We analyzed some important parameters characterizing respiratory and cardiovascular systems. We tried to identify statistically significant difference of parameters between patients with COPD and those with COPD and CHF. Moreover, patients with CHF were evaluated as a whole, and separately with reduced and with preserved systolic function. Results. Thus, we observed significant deterioration in general clinical, laboratory, spirometric and echocardiographic parameters depending on the presence and severity of CHF in patients with COPD. In particular, the presence of CHF, especially with impaired systolic function significantly impair indicators such as incidence of cardiac arrhythmias and signs of ischemia on the ECG, NT-proBNP levels, prevalence of concentric, eccentric hypertrophy and concentric LV remodeling and diastolic dysfunction type "relaxation disorder", and incidence of a-wave absence during assessment of motion of the rear pulmonary artery valve wall. Listed changes as well as some of the tendencies that have not reached a certain level of significance, indicate that patients with COPD and concomitant CHF, especially with impaired systolic function, worsens general clinical parameters (breath rate, systolic blood pressure, heart rate, frequency arrhythmias and myocardial ischemia on ECG; laboratory levels of hemoglobin, hematocrit, cholesterol, glomerular filtration rate; spirometric indicators of bronchial obstruction (FEV1, FVC, instant volume expiratory flow rates; echocardiographic indicators suggest the

  3. The Effects of Leucine, Zinc, and Chromium Supplements on Inflammatory Events of the Respiratory System in Type 2 Diabetic Rats

    Kolahian, Saeed; Sadri, Hassan; Shahbazfar, Amir Ali; Amani, Morvarid; Mazadeh, Anis; Mirani, Mehdi

    2015-01-01

    Diabetes mellitus is a major cause of serious micro- and macrovascular diseases that affect nearly every system in the body, including the respiratory system. Non-enzymatic protein glycation due to hyperglycaemic stress has fundamental implications due to the large capillary network and amount of connective tissue in the lung. The current study was designed to determine whether leucine, zinc, and chromium supplementations influence the function and histological structure of the respiratory tract in a rat model of type 2 diabetes. Seventy-seven rats were divided into eleven groups, consisting of 7 animals each. One group served as negative control and insulin and glibenclamide were used as positive control drugs. Thus, eight groups received the nutritional supplements alone or in combination with each other. Nutritional supplements and glibenclamide were added to the drinking water and neutral protamine Hagedorn insulin was subcutaneously injected during the 4 weeks of treatment period. The induction of type 2 diabetes in the rats caused an infiltration of mononuclear cells and edema in the submucosa of the trachea and lung, severe fibrosis around the vessels and airways, and perivascular and peribronchial infiltration of inflammatory cells and fibrin. In the diabetic group, the total inflammation score and Reid index significantly increased. Diabetes induction significantly reduced the total antioxidant status and elevated the lipid peroxidation products in the serum, lung lavage and lung tissue of the diabetic animals. Treatment with nutritional supplements significantly decreased the histopathological changes and inflammatory indices in the diabetic animals. Supplementation of diabetic rats with leucine, zinc, and chromium, alone and in combination, significantly increased the total antioxidant status and lipid peroxidation level in the diabetic animals. The nutritional supplements improved the enzymatic antioxidant activity of catalase, glutathione peroxidase

  4. Adenosine A1 receptor mRNA expression and the effects of systemic theophylline administration on respiratory function 4 months after C2 hemisection.

    Nantwi, Kwaku D; Basura, Gregory J; Goshgarian, Harry G

    2003-01-01

    Previous studies from our laboratory have demonstrated that in an animal model of acute cervical spinal cord injury (SCI), respiratory function can be restored by theophylline. We also have shown that respiratory recovery occurs spontaneously after prolonged postinjury survival periods when a hemidiaphragm is paralyzed by an ipsilateral upper cervical (C2) spinal cord hemisection. Theophylline mediates functional recovery by central nervous system adenosine A1 receptor antagonism; however, it is unclear whether adenosine receptors are altered after prolonged postinjury periods and whether theophylline can further enhance restored respiratory function that occurs spontaneously. To assess putative effects of systemic theophylline administration on further enhancing spontaneous respiratory muscle recovery 4 months after C2 hemisection in rats and to determine whether adenosine A1 receptor mRNA expression is altered in these animals. Electrophysiologic assessment of respiratory activity in the phrenic nerves was conducted in C2 hemisected rats 4 months after hemisection under standardized conditions. Immediately thereafter, rats were killed and the cervical spinal cords were prepared for adenosine A1 receptor mRNA expression by in situ hybridization. Spontaneous recovery of respiratory activity in the ipsilateral phrenic nerve was detected in a majority (15/20) of C2 hemisected animals and amounted to 44.06% +/- 2.38% when expressed as a percentage of activity in the homolateral phrenic nerve in noninjured animals. At the optimal dosage used in the acute studies, theophylline (15 mg/kg) did not enhance, but rather unexpectedly blocked, recovered respiratory activity in 4 out of 5 animals tested. At dosages of 5 mg/kg and 2.5 mg/kg, the drug blocked recovered respiratory activity in 3 out of 4 and 3 out of 5 animals tested, respectively. Quantitative analysis of adenosine A1 receptor mRNA expression did not reveal a significant difference between experimental animals

  5. Impact of a radio frequency management information system on the process and timing of providing respiratory care services.

    Stoller, James K; Kester, Lucy; Orens, Douglas K; McCarthy, Kevin

    2002-08-01

    Although radio frequency (RF) systems have proliferated and are designed to simplify care delivery in many clinical settings, little information is available on the impact of such RF systems on the delivery of patient care. Having used a hand-held-device-based management information system in our Respiratory Therapy Section for 16 years, we assessed the impact of an RF system on the delivery of respiratory therapy (RT) services. A single nursing unit dedicated to pulmonary and ear, nose, and throat care was selected for the RF system trial. Baseline (pre-RF) data were collected over 2 separate 1-month intervals (February 1999 and February 2000). The main outcome measures were (1) the amount of time needed at the beginning of the shift to organize and assign orders for RT services, (2) the time interval between notification of an RT consult order and completion of the RT consult, and (3) the time interval between notification of an RT treatment order and completion of the RT treatment. The activities required for organizing and assigning the orders were manually timed. Starting 6 weeks after therapists were trained to use the RF system, similar data were collected while using the RF system for two 1-month intervals (February and March 2001). The mean +/- SD time interval between receiving an RT consult order and completing the consult was reduced from 7.8 +/- 18.9 h to 2.8 +/- 2.4 h (p = 0.002). The percentage of patients who waited longer than 8 hours between receipt of a consult order and completion of the consult decreased from 18% to 4.7% (p = 0.026). The total time required for organizing and assigning RT work was reduced from 81.6 min to 43.6 min. The RF system had several advantages over the hand-held-device-based system: (1) shorter interval between the order for and completion of an RT consult, (2) lower percentage of patients for whom the interval between the order and the consult exceeded 8 hours, and (3) less time required to make shift assignments

  6. A mathematical model of transport and regional uptake of radioactive gases in the human respiratory system

    Baek, Inseok

    The purpose of this research is to describe the development of a mathematical model of diffusion, convection, and lateral transport into the airway wall and alveolar absorption for inhaled radioactive gases in the human conductive and respiratory airways based on a Single Path Trumpet-bell model (SPM). Mathematical simulation models have been used successfully to study transport, absorption into the blood through alveoli, and lung tissue uptake of soluble and nonreactive radioactive gases. Results from such simulations also show clearly that inhaled radioactive gases are absorbed into the lung tissues as well as into the blood through the alveoli. In contrast to previous reports in the literature, the present study found that blood uptake through alveoli is much greater than that calculated previously. Regional depositions in the lung from inhaled radioactive gases are presented as the result of this simulation. The committed effective dose to lung tissue due to submersion in radioactive clouds has been newly defined using the results of this simulation.

  7. [The changes of physiological reactivity of cardiorespiratory system to respiratory homeostasis with the use of complex stimulation of special work capacity].

    Lysenko, O M

    2012-01-01

    We present the influence of the program of special additional stimulation of work capacity of high-performance athletes on the sensitivity of cardiorespiratory system to hypercapnic and hypoxic shifts in respiratory homeostasis. We found that under the influence of the pre-start complex a decrease in the sensitivity of ventilator responses to CO2-H+ stimuli in combination with a reduction in the thresholds of the reaction take place. This creates conditions for increased mobilization properties of the cardiorespiratory system and economization of its reaction under conditions of changes of respiratory homeostasis characteristic of intense training and competitive loads in the sport.

  8. Maternal and Fetal Recovery After Severe Respiratory Failure: A Case Report of Air Transportation of a Pregnant Woman on ECMO Using the CentriMag Transporter System.

    Kaliyev, Rymbay; Kapyshev, Timur; Goncharov, Alex; Lesbekov, Timur; Pya, Yuri

    2015-01-01

    Use of extracorporeal membrane oxygenation (ECMO) for severe cardiopulmonary failure has increased because of improved outcomes. A specially designed ECMO transport system allows for safe transport of patients over long distances. We report a 28-year-old pregnant woman (26 weeks gestation) with acute respiratory distress syndrome in whom ECMO support was necessary for survival, and she was transported to another facility 1,155 km away with the aid of the portable ECMO system. Transport was uneventful, and the patient's condition remained stable. Acute respiratory distress syndrome improved gradually until the patient was discharged from the hospital with excellent maternal and fetal outcome.

  9. Implementing systems thinking for infection prevention: The cessation of repeated scabies outbreaks in a respiratory care ward.

    Chuang, Sheuwen; Howley, Peter P; Lin, Shih-Hua

    2015-05-01

    Root cause analysis (RCA) is often adopted to complement epidemiologic investigation for outbreaks and infection-related adverse events in hospitals; however, RCA has been argued to have limited effectiveness in preventing such events. We describe how an innovative systems analysis approach halted repeated scabies outbreaks, and highlight the importance of systems thinking for outbreaks analysis and sustaining effective infection prevention and control. Following RCA for a third successive outbreak of scabies over a 17-month period in a 60-bed respiratory care ward of a Taiwan hospital, a systems-oriented event analysis (SOEA) model was used to reanalyze the outbreak. Both approaches and the recommendations were compared. No nosocomial scabies have been reported for more than 1975 days since implementation of the SOEA. Previous intervals between seeming eradication and repeat outbreaks following RCA were 270 days and 180 days. Achieving a sustainable positive resolution relied on applying systems thinking and the holistic analysis of the system, not merely looking for root causes of events. To improve the effectiveness of outbreaks analysis and infection control, an emphasis on systems thinking is critical, along with a practical approach to ensure its effective implementation. The SOEA model provides the necessary framework and is a viable complementary approach, or alternative, to RCA. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Obesity and respiratory diseases

    Christopher Zammit

    2010-10-01

    Full Text Available Christopher Zammit, Helen Liddicoat, Ian Moonsie, Himender MakkerSleep and Ventilation Unit, Department of Respiratory Medicine, North Middlesex University Hospital, London, UKAbstract: The obesity epidemic is a global problem, which is set to increase over time. However, the effects of obesity on the respiratory system are often underappreciated. In this review, we will discuss the mechanical effects of obesity on lung physiology and the function of adipose tissue as an endocrine organ producing systemic inflammation and effecting central respiratory control. Obesity plays a key role in the development of obstructive sleep apnea and obesity hypoventilation syndrome. Asthma is more common and often harder to treat in the obese population, and in this study, we review the effects of obesity on airway inflammation and respiratory mechanics. We also discuss the compounding effects of obesity on chronic obstructive pulmonary disease (COPD and the paradoxical interaction of body mass index and COPD severity. Many practical challenges exist in caring for obese patients, and we highlight the complications faced by patients undergoing surgical procedures, especially given the increased use of bariatric surgery. Ultimately, a greater understanding of the effects of obesity on the respiratory disease and the provision of adequate health care resources is vital in order to care for this increasingly important patient population.Keywords: obesity, lung function, obstructive sleep apnea, obesity hypoventilation syndrome, anesthesia

  11. Real-time PCR quantification of the plant growth promoting bacteria Herbaspirillum seropedicae strain SmR1 in maize roots.

    Pereira, Tomás Pellizzaro; do Amaral, Fernanda Plucani; Dall'Asta, Pamela; Brod, Fábio Cristiano Angonesi; Arisi, Ana Carolina Maisonnave

    2014-07-01

    The plant growth promoting bacteria Herbaspirillum seropedicae SmR1 is an endophytic diazotroph found in several economically important crops. Considering that methods to monitor the plant-bacteria interaction are required, our objective was to develop a real-time PCR method for quantification of PGPB H. seropedicae in the rhizosphere of maize seedlings. Primer pairs were designed, and their specificity was verified using DNA from 12 different bacterial species. Ten standard curves of qPCR assay using HERBAS1 primers and tenfold serial dilutions of H. seropedicae SmR1 DNA were performed, and PCR efficiency of 91 % and correlation coefficient of 0.99 were obtained. H. seropedicae SmR1 limit of detection was 10(1) copies (corresponding to 60.3 fg of bacterial DNA). qPCR assay using HERBAS1 was used to detect and quantify H. seropedicae strain SmR1 in inoculated maize roots, cultivated in vitro and in pots, harvested 1, 4, 7, and 10 days after inoculation. The estimated bacterial DNA copy number per gram of root was in the range 10(7)-10(9) for plants grown in vitro and it was around 10(6) for plants grown in pots. Primer pair HERBAS1 was able to quantify H. seropedicae SmR1, and this assay can be useful for monitoring plant-bacteria interaction.

  12. Respiratory Home Health Care

    ... Us Home > Healthy Living > Living With Lung Disease > Respiratory Home Health Care Font: Aerosol Delivery Oxygen Resources ... Teenagers Living With Lung Disease Articles written by Respiratory Experts Respiratory Home Health Care Respiratory care at ...

  13. The effect of tumor location and respiratory function on tumor movement estimated by real-time tracking radiotherapy (RTRT) system

    Onimaru, Rikiya; Shirato, Hiroki; Fujino, Masaharu; Suzuki, Keishiro; Yamazaki, Kouichi; Nishimura, Masaharu; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2005-01-01

    Purpose: The effects of tumor location and pulmonary function on the motion of fiducial markers near lung tumors were evaluated to deduce simple guidelines for determining the internal margin in radiotherapy without fiducial markers. Methods and Materials: Pooled data collected by a real-time tumor-tracking radiotherapy system on 42 markers in 39 patients were analyzed. The pulmonary functions of all patients were assessed before radiotherapy. Using chest X-ray film, the position of the marker was expressed relative to the geometry of the unilateral lung. Posterior location meant the area of the posterior half of the lung in a lateral chest X-ray film, and caudal location meant the caudal half of the chest X-ray film; these categories were determined by measuring the distance between the marker and anatomic landmarks, including the apex, costophrenic angle, midline of spinal canal, lateral, anterior, and posterior boundary of the lung. Results: Before the radiotherapy, 18 patients had obstructive respiratory dysfunction (ratio of forced expiratory volume in 1 s to forced vital capacity [FEV 1.0 /FVC] 1.0 /FVC and %VC were 97.0% and 66.5%, respectively. Median tumor movements in the x (left-right), y (anteroposterior), and z (craniocaudal) directions were 1.1 mm, 2.3 mm, and 5.4 mm, respectively. There was no significant correlation between respiratory function and magnitude of marker movement in any direction. Median marker movement in the z direction was 2.6 mm for the cranial location and 11.8 mm for the caudal location, respectively (p < 0.001). Median movement in the z direction was 11.8 mm for posterior location and 3.4 mm for anterior location, respectively (p < 0.01). Conclusions: Simple measurement of the relative location on plain chest X-ray film was related, but respiratory function test was not related, to the craniocaudal amplitude of the motion of the fiducial marker near lung tumors

  14. The effects of individually ventilated cages on the respiratory systems of male and female Wistar rats from birth until adulthood

    Guilherme D’Aprile Marchesi

    Full Text Available OBJECTIVE: To evaluate the respiratory systems of male and female rats maintained in individually ventilated cages (IVCs from birth until adulthood. METHODS: Female Wistar rats were housed in individually ventilated cages or conventional cages (CCs and mated with male Wistar rats. After birth and weaning, the male offspring were separated from the females and kept in cages of the same type until 12 weeks of age. RESULTS: The level of food consumption was lower in male offspring (IVC=171.7±9; CC=193.1±20 than in female offspring (IVC=100.6±7; CC=123.4±0.4, whereas the water intake was higher in female offspring (IVC=149.8±11; CC=99.2±0 than in male offspring (IVC=302.5±25; CC=249.7±22 at 11 weeks of age when housed in IVCs. The cage temperature was higher in individually ventilated cages than in conventional cages for both male (IVCs=25.9±0.5; CCs=22.95±0.3 and female (IVCs=26.2±0.3; CCs=23.1±0.3 offspring. The respiratory resistance (IVC=68.8±2.8; CC=50.6±3.0 and elastance (IVC=42.0±3.9; CC=32.4±2.0 at 300 µm/kg were higher in the female offspring housed in ventilated cages. The ciliary beat values were lower in both the male (IVCs=13.4±0.2; CC=15±0.4 and female (IVC=13.5±0.4; CC=15.9±0.6 offspring housed in individually ventilated cages than in those housed in conventional cages. The total cell (IVC=117.5±9.7; CC=285.0±22.8, neutrophil (IVC=13.1±4.8; CC=75.6±4.1 and macrophage (IVC=95.2±11.8; CC=170.0±18.8 counts in the bronchoalveolar lavage fluid were lower in the female offspring housed in individually ventilated cages than in those housed in conventional cages. CONCLUSIONS: The environmental conditions that exist in individually ventilated cages should be considered when interpreting the results of studies involving laboratory animals. In this study, we observed gender dimorphism in both the water consumption and respiratory mechanics of rats kept in ventilated cages.

  15. The effects of individually ventilated cages on the respiratory systems of male and female Wistar rats from birth until adulthood

    Marchesi, Guilherme D’Aprile; de Fatima Soto, Sônia; de Castro, Isac; Rodrigues, Thiago Guimarães; Moriya, Henrique Takachi; de Almeida, Francine Maria; Pazetti, Rogerio; Heimann, Joel Claudio; Furukawa, Luzia Naôko Shinohara

    2017-01-01

    OBJECTIVE: To evaluate the respiratory systems of male and female rats maintained in individually ventilated cages (IVCs) from birth until adulthood. METHODS: Female Wistar rats were housed in individually ventilated cages or conventional cages (CCs) and mated with male Wistar rats. After birth and weaning, the male offspring were separated from the females and kept in cages of the same type until 12 weeks of age. RESULTS: The level of food consumption was lower in male offspring (IVC=171.7±9; CC=193.1±20) than in female offspring (IVC=100.6±7; CC=123.4±0.4), whereas the water intake was higher in female offspring (IVC=149.8±11; CC=99.2±0) than in male offspring (IVC=302.5±25; CC=249.7±22) at 11 weeks of age when housed in IVCs. The cage temperature was higher in individually ventilated cages than in conventional cages for both male (IVCs=25.9±0.5; CCs=22.95±0.3) and female (IVCs=26.2±0.3; CCs=23.1±0.3) offspring. The respiratory resistance (IVC=68.8±2.8; CC=50.6±3.0) and elastance (IVC=42.0±3.9; CC=32.4±2.0) at 300 µm/kg were higher in the female offspring housed in ventilated cages. The ciliary beat values were lower in both the male (IVCs=13.4±0.2; CC=15±0.4) and female (IVC=13.5±0.4; CC=15.9±0.6) offspring housed in individually ventilated cages than in those housed in conventional cages. The total cell (IVC=117.5±9.7; CC=285.0±22.8), neutrophil (IVC=13.1±4.8; CC=75.6±4.1) and macrophage (IVC=95.2±11.8; CC=170.0±18.8) counts in the bronchoalveolar lavage fluid were lower in the female offspring housed in individually ventilated cages than in those housed in conventional cages. CONCLUSIONS: The environmental conditions that exist in individually ventilated cages should be considered when interpreting the results of studies involving laboratory animals. In this study, we observed gender dimorphism in both the water consumption and respiratory mechanics of rats kept in ventilated cages. PMID:28355363

  16. Comparison of Respiratory Disease Prevalence among Voluntary Monitoring Systems for Pig Health and Welfare in the UK.

    J I Eze

    Full Text Available Surveillance of animal diseases provides information essential for the protection of animal health and ultimately public health. The voluntary pig health schemes, implemented in the United Kingdom, are integrated systems which capture information on different macroscopic disease conditions detected in slaughtered pigs. Many of these conditions have been associated with a reduction in performance traits and consequent increases in production costs. The schemes are the Wholesome Pigs Scotland in Scotland, the BPEX Pig Health Scheme in England and Wales and the Pig Regen Ltd. health and welfare checks done in Northern Ireland. This report set out to compare the prevalence of four respiratory conditions (enzootic pneumonia-like lesions, pleurisy, pleuropneumonia lesions and abscesses in the lung assessed by these three Pig Health Schemes. The seasonal variations and year trends associated with the conditions in each scheme are presented. The paper also highlights the differences in prevalence for each condition across these schemes and areas where further research is needed. A general increase in the prevalence of enzootic pneumonia like lesions was observed in Scotland, England and Wales since 2009, while a general decrease was observed in Northern Ireland over the years of the scheme. Pleurisy prevalence has increased since 2010 in all three schemes, whilst pleuropneumonia has been decreasing. Prevalence of abscesses in the lung has decreased in England, Wales and Northern Ireland but has increased in Scotland. This analysis highlights the value of surveillance schemes based on abattoir pathology monitoring of four respiratory lesions. The outputs at scheme level have significant value as indicators of endemic and emerging disease, and for producers and herd veterinarians in planning and evaluating herd health control programs when comparing individual farm results with national averages.

  17. Comparison of Respiratory Disease Prevalence among Voluntary Monitoring Systems for Pig Health and Welfare in the UK.

    Eze, J I; Correia-Gomes, C; Borobia-Belsué, J; Tucker, A W; Sparrow, D; Strachan, D W; Gunn, G J

    2015-01-01

    Surveillance of animal diseases provides information essential for the protection of animal health and ultimately public health. The voluntary pig health schemes, implemented in the United Kingdom, are integrated systems which capture information on different macroscopic disease conditions detected in slaughtered pigs. Many of these conditions have been associated with a reduction in performance traits and consequent increases in production costs. The schemes are the Wholesome Pigs Scotland in Scotland, the BPEX Pig Health Scheme in England and Wales and the Pig Regen Ltd. health and welfare checks done in Northern Ireland. This report set out to compare the prevalence of four respiratory conditions (enzootic pneumonia-like lesions, pleurisy, pleuropneumonia lesions and abscesses in the lung) assessed by these three Pig Health Schemes. The seasonal variations and year trends associated with the conditions in each scheme are presented. The paper also highlights the differences in prevalence for each condition across these schemes and areas where further research is needed. A general increase in the prevalence of enzootic pneumonia like lesions was observed in Scotland, England and Wales since 2009, while a general decrease was observed in Northern Ireland over the years of the scheme. Pleurisy prevalence has increased since 2010 in all three schemes, whilst pleuropneumonia has been decreasing. Prevalence of abscesses in the lung has decreased in England, Wales and Northern Ireland but has increased in Scotland. This analysis highlights the value of surveillance schemes based on abattoir pathology monitoring of four respiratory lesions. The outputs at scheme level have significant value as indicators of endemic and emerging disease, and for producers and herd veterinarians in planning and evaluating herd health control programs when comparing individual farm results with national averages.

  18. The impact of the environmental and socio-economic factors to the occurrence of symptoms and diseases of the respiratory system in school children from Sosnowiec

    Magda Skiba

    2012-12-01

    Full Text Available Background: Objective of the study was to assess the impact of environmental and socio-economic factors to the occurrence of symptoms and diseases of the respiratory system in school children from Sosnowiec, based on the questionnaire data. Materials and methods: The crosssectional epidemiological questionnaire study was performed in the years 2005–2006. Parents of 709 primary school children aged 7–12 years took part in the study. Questionnaire was completed by parents to collect information on children health status, particularly respiratory symptoms, chronic diseases of respiratory system, allergic diseases, use of medical services, children dietary habits and family socio-economic status. Results: In the study group the statistical significance was found for the incidence of respiratory symptoms in children and housing conditions, i.e.: the number of people sleeping together with a child in the same room and dampness in the dwelling. Results of the study showed, that incidence of whizzing differed statistically significantly in the groups of different professional status of the parents. It is difficult to estimate if this is only the influence of socio-economic conditions or any other environmental factors as well. Conclusions: Results of the study demonstrated statistical significance between the status of respiratory system in children and housing occupancy rate (the number of people sleeping together with a child in the same room and dampness in the dwelling. Relation between respiratory symptoms in children, parents education and professional status was analyzed, but findings of the conducted studies do not give explicit evidence of such a relation.

  19. Respiratory Systems of Dental Technicians Negatively Affected during 5 Years of Follow-Up

    Nurgül Bozkurt

    2016-08-01

    forced expiratory volume in one second (FEV1. While restrictive disorder was found 25% in the first PFT evaluations, this ratio increased to 31% in the second PFT. When the radiological results were considered, 62% of the first X-ray results were found to be normal but this ratio decreased to 18% in 2013. While reticular/reticulonodular opacities were found in 11% of cases in 2008, it increased to 30% in 2013. Seven technicians were diagnosed with pneumoconiosis (5.6%. Conclusion: Respiratory tracts of the technicians were negatively affected during the five year period. The number of pneumoconiosis cases (5.6% shows that it is necessary to adopt comprehensive work health and safety precautions for laboratories.

  20. Influence of outdoor games on functional condition of the respiratory system at girls of the younger school age

    Оlena Potapova

    2016-10-01

    Full Text Available Purpose: to study influence of outdoor games on functional condition of the respiratory system of girls of the younger school age in the groups of 6–8 and 9–10 years old. Material & Methods: the problem of functional condition of external breath at girls of the younger school age (in the age groups of 6–8 and 9–10 years old, who were divided into the control group (CG in number of 32persons (CS No. 58 and the experimental (EG in number of 29 persons (OTEC No. 109 of Zaporozhe, is considered. Results: it is defined that the studied girls of both groups at the beginning of the research had mainly below average and average levels of functional condition of the system of external breath. Conclusions: the effective impact of outdoor games on functional condition of the whole organism in general and on the system of external breath, in particular, at girls of the experimental group in comparison with the studied girls of the same age of the control group is proved experimentally. Application of the large number of various outdoor games allowed diversifying the program of training at physical education classes emotionally and physically, than promoted the activation of functions of the whole organism of girls of the younger school age.

  1. Air conditioning systems as non-infectious health hazards inducing acute respiratory symptoms.

    Gerber, Alexander; Fischer, Axel; Willig, Karl-Heinz; Groneberg, David A

    2006-04-01

    Chronic and acute exposure to toxic aerosols belongs to frequent causes of airway diseases. However, asthma attacks due to long-distance inhalative exposure to organic solvents, transmitted via an air condition system, have not been reported so far. The present case illustrates the possibility of air conditioning systems as non-infectious health hazards in occupational medicine. So far, only infectious diseases such as legionella pneumophila pneumonia have commonly been associated to air-conditioning exposures but physicians should be alert to the potential of transmission of toxic volatile substances via air conditioning systems. In view of the events of the 11th of September 2001 with a growing danger of large building terrorism which may even use air conditioning systems to transmit toxins, facility management security staff should be alerted to possible non-infectious toxic health hazards arising from air-conditioning systems.

  2. SU-E-T-247: Determinations of the Optimal Phase for Respiratory Gated Radiotherapy From Statistical Analysis Using a Visible Guidance System

    Oh, S; Yea, J; Kang, M; Lee, H; Kim, S [Yeungnam University Medical Center, Daegu, Daegu (Korea, Republic of)

    2015-06-15

    Purpose: Respiratory gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung cancer patients. Determination of the optimal point in the respiratory phase of a patient is important in RGRT but it is not easy. The goal of the present study was to see if a visible guidance system is helpful in determining the optimal phase in respiratory gated therapy. Methods: The breathing signals of 23 lung cancer patients were recorded with a Real-time Position Management (RPM) respiratory gating system (Varian, USA). The patients underwent breathing training with our visible guidance system, after which their breathing signals were recorded during 5 min of free breathing and 5 min of guided breathing. The breathing signals recorded between 3 and 5 min before and after training were compared. We performed statistical analysis of the breathing signals to find the optimal duty cycle in guided breathing for RGRT. Results: The breathing signals aided by the visible guidance system had more regular cycles over time and smaller variations in the positions of the marker block than the free breathing signals. Of the 23 lung cancer patients, 19 showed statistically significant differences by time when the values obtained before and after breathing were compared (p < 0.05); 30% and 40% of the duty cycle, respectively, was determined to be the most effective, and the corresponding phases were 30 60% (duty cycle, 30%; p < 0.05) and 30 70% (duty cycle, 40%; p < 0.05). Conclusion: Respiratory regularity was significantly improved with the use of the RPM with our visible guiding system; therefore, it would help improve the accuracy and efficiency of RGRT.

  3. Decreased respiratory system compliance on the sixth day of mechanical ventilation is a predictor of death in patients with established acute lung injury

    Matthay Michael A

    2011-04-01

    Full Text Available Abstract Background Multiple studies have identified single variables or composite scores that help risk stratify patients at the time of acute lung injury (ALI diagnosis. However, few studies have addressed the important question of how changes in pulmonary physiologic variables might predict mortality in patients during the subacute or chronic phases of ALI. We studied pulmonary physiologic variables, including respiratory system compliance, P/F ratio and oxygenation index, in a cohort of patients with ALI who survived more than 6 days of mechanical ventilation to see if changes in these variables were predictive of death and whether they are informative about the pathophysiology of subacute ALI. Methods Ninety-three patients with ALI who were mechanically ventilated for more than 6 days were enrolled in this prospective cohort study. Patients were enrolled at two medical centers in the US, a county hospital and a large academic center. Bivariate analyses were used to identify pulmonary physiologic predictors of death during the first 6 days of mechanical ventilation. Predictors on day 1, day 6 and the changes between day 1 and day 6 were compared in a multivariate logistic regression model. Results The overall mortality was 35%. In multivariate analysis, the PaO2/FiO2 (OR 2.09, p th day of acute lung injury. In addition, a decrease in respiratory system compliance between days 1 and days 6 (OR 2.14, p Conclusions A low respiratory system compliance on day 6 or a decrease in the respiratory system compliance between the 1st and 6th day of mechanical ventilation were associated with increased mortality in multivariate analysis of this cohort of patients with ALI. We suggest that decreased respiratory system compliance may identify a subset of patients who have persistent pulmonary edema, atelectasis or the fibroproliferative sequelae of ALI and thus are less likely to survive their hospitalization.

  4. High frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice.

    Hadden, Hélène

    2013-01-15

    We tested the hypothesis that high frequency ventilation affects respiratory system mechanical functions in C57BL/6J and BALB/c mice. We measured respiratory mechanics by the forced oscillation technique over 1h in anesthetized, intubated, ventilated BALB/c and C57BL/6J male mice. We did not detect any change in airway resistance, Rn, tissue damping, G, tissue elastance, H and hysteresivity, eta in BALB/c mice during 1h of ventilation at 150 or at 450 breaths/min; nor did we find a difference between BALB/c mice ventilated at 150 breaths/min compared with 450 breaths/min. Among C57BL/6J mice, except for H, all parameters remained unchanged over 1h of ventilation in mice ventilated at 150 breaths/min. However, after 10 and 30 min of ventilation at 450 breaths/min, Rn, and respiratory system compliance were lower, and eta was higher, than their starting value. We conclude that high frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Classification of Normal Subjects and Pulmonary Function Disease Patients using Tracheal Respiratory Sound Detection System

    Im, Jae Joong; Yi, Young Ju; Jeon, Young Ju [Chonbuk National University (Korea)

    2000-04-01

    A new auscultation system for the detection of breath sound from trachea was developed in house. Small size microphone(panasonic pin microphone) was encapsuled in a housing for resonant effect, and hardware for the sound detection was fabricated. Pulmonary function test results were compared with the parameters extracted from frequency spectrum of breath sound obtained from the developed system. Results showed that the peak frequency and relative ratio of integral values between low(80-400Hz) and high(400-800Hz) frequency ranges revealed the significant differences. Developed system could be used for distinguishing normal subject and the patients who have pulmonary disease. (author). 13 refs., 9 figs.

  6. Respiratory Effects and Systemic Stress Response Following Acute Acrolein Inhalation in Rats

    U.S. Environmental Protection Agency — This data set is an Excel file pertaining to the study that examined nasal, pulmonary, and systemic effects of acrolein in rats acutely exposed to a range of...

  7. Respiratory Effects and Systemic Stress Response Following Acute Acrolein Inhalation in Rats.

    Previous studies have demonstrated that exposure to the pulmonary irritant ozone causes myriad systemic metabolic and pulmonary effects attributed to sympathetic and hypothalamus-pituitary-adrenal (HPA) axis activation, which are exacerbated in metabolically impaired models. We...

  8. Respiratory Effects and Systemic Stress Response Following Acute Acrolein Inhalation in Rats

    Previous studies have demonstrated that exposure to ozone, a pulmonary irritant, causes myriad systemic metabolic and pulmonary effects that are attributed to neuronal and hypothalamus-pituitary-adrenal (HPA) axis activation, which are exacerbated in metabolically-impaired models...

  9. The Streptococcus pneumoniae Competence Regulatory System Influences Respiratory Tract Colonization ▿

    Kowalko, J. E.; Sebert, M. E.

    2008-01-01

    The Streptococcus pneumoniae ComDE two-component signaling system controls the development of genetic competence in the bacterium and affects virulence in models of pneumonia and bacteremia. We have investigated the impact of the competence pathway during colonization of the nasopharynx, the principal ecological niche of the pneumococcus. Previous work showed that deletion of the pneumococcal CiaRH signaling system inhibited colonization and increased expression of genes required for competen...

  10. Body temperature and motion: Evaluation of an online monitoring system in pigs challenged with Porcine Reproductive & Respiratory Syndrome Virus.

    Süli, Tamás; Halas, Máté; Benyeda, Zsófia; Boda, Réka; Belák, Sándor; Martínez-Avilés, Marta; Fernández-Carrión, Eduardo; Sánchez-Vizcaíno, José Manuel

    2017-10-01

    Highly contagious and emerging diseases cause significant losses in the pig producing industry worldwide. Rapid and exact acquisition of real-time data, like body temperature and animal movement from the production facilities would enable early disease detection and facilitate adequate response. In this study, carried out within the European Union research project RAPIDIA FIELD, we tested an online monitoring system on pigs experimentally infected with the East European subtype 3 Porcine Reproductive & Respiratory Syndrome Virus (PRRSV) strain Lena. We linked data from different body temperature measurement methods and the real-time movement of the pigs. The results showed a negative correlation between body temperature and movement of the animals. The correlation was similar with both body temperature obtaining methods, rectal and thermal sensing microchip, suggesting some advantages of body temperature measurement with transponders compared with invasive and laborious rectal measuring. We also found a significant difference between motion values before and after the challenge with a virulent PRRSV strain. The decrease in motion values was noticeable before any clinical sign was recorded. Based on our results the online monitoring system could represent a practical tool in registering early warning signs of health status alterations, both in experimental and commercial production settings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Respiratory care manpower issues.

    Mathews, Paul; Drumheller, Lois; Carlow, John J

    2006-03-01

    Although respiratory care is a relatively new profession, its practitioners are deeply involved in providing patient care in the critical care. In preparation for writing this article, we sought to explore the respiratory therapy manpower needs and activities designed to fulfill those needs in critical care practice. We began by delineating the historical development of respiratory care as a profession, the development of its education, and the professional credentialing system. We then conducted several literature reviews with few articles generated. We requested and received data from the American Association for Respiratory Care (AARC), The National Board for Respiratory Care (NBRC), and the Committee on Accreditation of Respiratory Care education (CoARC) relative to their membership, number of credentialed individuals, and educational program student and graduate data for 2000 through 2004. We then conducted two electronic surveys. Survey 1 was a six-item survey that examined the use of mandatory overtime in respiratory care departments. We used a convenience sample of 30 hospitals stratified by size (or=500 beds). Survey 2 was a five-item instrument distributed by blast E-mail to the Society of Critical Care Medicine's Respiratory Care Section members and members of the RC_World list serve. This survey elicited 51 usable and non-duplicative responses from geographically and size-varied institutions. We analyzed these data in several ways from distribution analysis to one-way analysis of variance procedure and appropriate post hoc analysis techniques. Where appropriate, a matched-pairs analysis was performed and these were compared across the variables intensive care unit (ICU) beds per actual number of respiratory care practitioners (RCPs) and ICU beds per preferred number of RCPs. The data gathered from the professional organizations indicated a relatively stable attrition rate (35.2%+/-1.7-3.1%), even in the face of varying enrollments (6,231 in 2004 vs. 4

  12. Measuring the respiratory gas exchange of grazing cattle using the GreenFeed emissions monitoring system

    Ruminants are a significant source of enteric methane, which has been identified as a powerful greenhouse gas that contributes to climate change. With interest in developing technologies to decrease enteric methane emission, systems are currently being developed to measure the methane emission by c...

  13. Systemic Foot-and-Mouth Disease Vaccination in Cattle Promotes Specific Antibody-Secreting Cells at the Respiratory Tract and Triggers Local Anamnestic Responses upon Aerosol Infection.

    Pega, J; Di Giacomo, S; Bucafusco, D; Schammas, J M; Malacari, D; Barrionuevo, F; Capozzo, A V; Rodríguez, L L; Borca, M V; Pérez-Filgueira, M

    2015-09-01

    Foot-and-mouth disease (FMD) is a highly contagious viral disease affecting biungulate species. Commercial vaccines, formulated with inactivated FMD virus (FMDV), are regularly used worldwide to control the disease. Here, we studied the generation of antibody responses in local lymphoid tissues along the respiratory system in vaccinated and further aerosol-infected cattle. Animals immunized with a high-payload monovalent FMD vaccine developed high titers of neutralizing antibodies at 7 days postvaccination (dpv), reaching a plateau at 29 dpv. FMDV-specific antibody-secreting cells (ASC), predominantly IgM, were evident at 7 dpv in the prescapular lymph node (LN) draining the vaccination site and in distal LN draining the respiratory mucosa, although in lower numbers. At 29 dpv, a significant switch to IgG1 was clear in prescapular LN, while FMDV-specific ASC were detected in all lymphoid tissues draining the respiratory tract, mostly as IgM-secreting cells. None of the animals (n = 10) exhibited FMD symptoms after oronasal challenge at 30 dpv. Three days postinfection, a large increase in ASC numbers and rapid isotype switches to IgG1 were observed, particularly in LN-draining virus replication sites already described. These results indicate for the first time that systemic FMD vaccination in cattle effectively promotes the presence of anti-FMDV ASC in lymphoid tissues associated with the respiratory system. Oronasal infection triggered an immune reaction compatible with a local anamnestic response upon contact with the replicating FMDV, suggesting that FMD vaccination induces the circulation of virus-specific B lymphocytes, including memory B cells that differentiate into ASC soon after contact with the infective virus. Over recent decades, world animal health organizations as well as national sanitary authorities have supported the use of vaccination as an essential component of the official FMD control programs in both endemic and disease-free settings. Very few

  14. A Review on Human Respiratory Modeling.

    Ghafarian, Pardis; Jamaati, Hamidreza; Hashemian, Seyed Mohammadreza

    2016-01-01

    Input impedance of the respiratory system is measured by forced oscillation technique (FOT). Multiple prior studies have attempted to match the electromechanical models of the respiratory system to impedance data. Since the mechanical behavior of airways and the respiratory system as a whole are similar to an electrical circuit in a combination of series and parallel formats some theories were introduced according to this issue. It should be noted that, the number of elements used in these models might be less than those required due to the complexity of the pulmonary-chest wall anatomy. Various respiratory models have been proposed based on this idea in order to demonstrate and assess the different parts of respiratory system related to children and adults data. With regard to our knowledge, some of famous respiratory models in related to obstructive, restrictive diseases and also Acute Respiratory Distress Syndrome (ARDS) are reviewed in this article.

  15. Influenza hospitalization epidemiology from a severe acute respiratory infection surveillance system in Jordan, January 2008?February 2014

    Al?Abdallat, Mohammad; Dawson, Patrick; Haddadin, Aktham Jeries; El?Shoubary, Waleed; Dueger, Erica; Al?Sanouri, Tarek; Said, Mayar M.; Talaat, Maha

    2016-01-01

    Background Acute respiratory infections (ARIs) are a major cause of morbidity and mortality worldwide. Influenza typically contributes substantially to the burden of ARI, but only limited data are available on influenza activity and seasonality in Jordan. Methods Syndromic case definitions were used to identify individuals with severe acute respiratory infections (SARI) admitted to four sentinel hospitals in Jordan. Demographic and clinical data were collected. Nasopharyngeal and oropharyngea...

  16. Respiratory bronchiolitis-associated interstitial lung disease secondary to electronic nicotine delivery system use confirmed with open lung biopsy.

    Flower, Mark; Nandakumar, Lakshmy; Singh, Mahendra; Wyld, David; Windsor, Morgan; Fielding, David

    2017-05-01

    As a modern phenomenon, there is currently limited understanding of the possible toxic effects and broader implications of electronic nicotine delivery systems (ENDS). Large volumes of aerosolized particles are inhaled during "vaping" and there are now an increasing number of case reports demonstrating toxic effects of ENDS, as well as human studies demonstrating impaired lung function in users. This article presents a case of respiratory bronchiolitis interstitial lung disease (RB-ILD) precipitated by vaping in a 33-year-old male with 10 pack years of traditional cigarette and prior treatment for mixed germ cell tumour. The patient had started vaping 10-15 times per day while continuing to smoke 10 traditional cigarettes per day. After 3 months of exposure to e-cigarette vapour, chest computed tomography demonstrated multiple new poorly defined pulmonary nodules with fluffy parenchyma opacification centred along the terminal bronchovascular units. Video-assisted thoracoscopy with lung biopsy of the right upper and right middle lobes was undertaken. The microscopic findings were overall consistent with RB-ILD. This case demonstrates toxicity with use of ENDS on open lung biopsy with resolution of radiographic findings on cessation. We believe that this is the first case where open lung biopsy has demonstrated this and our findings are consistent with RB-ILD.

  17. Trace metals in fluids lining the respiratory system of patients with idiopathic pulmonary fibrosis and diffuse lung diseases.

    Bargagli, Elena; Lavorini, Federico; Pistolesi, Massimo; Rosi, Elisabetta; Prasse, Antje; Rota, Emilia; Voltolini, Luca

    2017-07-01

    Idiopathic pulmonary fibrosis (IPF) is an interstitial lung disease with a poor prognosis and an undefined etiopathogenesis. Oxidative stress contributes to alveolar injury and fibrosis development and, because transition metals are essential to the functioning of most proteins involved in redox reactions, a better knowledge of metal concentrations and metabolism in the respiratory system of IPF patients may provide a valuable complementary approach to prevent and manage a disease which is often misdiagnosed or diagnosed in later stages. The present review summarizes and discusses literature data on the elemental composition of bronchoalveolar lavage (BAL), induced sputum and exhaled breath condensate (EBC) from patients affected by IPF and healthy subjects. Available data are scanty and the lack of consistent methods for the collection and analysis of lung and airways lining fluids makes it difficult to compare the results of different studies. However, the elemental composition of BAL samples from IPF patients seems to have a specific profile that can be distinguished from that of patients with other interstitial lung diseases (ILD) or control subjects. Suggestions are given towards standard sampling and analytical procedures of BAL samples, in the aim to assess typical element concentration patterns and their potential role as biomarkers of IPF. Copyright © 2017 Elsevier GmbH. All rights reserved.

  18. Effects of passive inhalation of cigarette smoke on structural and functional parameters in the respiratory system of guinea pigs

    Thiago Brasileiro de Vasconcelos

    Full Text Available ABSTRACT Objective: To evaluate the effects of passive inhalation of cigarette smoke on the respiratory system of guinea pigs. Methods: Male guinea pigs were divided into two groups: control and passive smoking, the latter being exposed to the smoke of ten cigarettes for 20 min in the morning, afternoon and evening (30 cigarettes/day for five days. After that period, inflammatory parameters were studied by quantifying mesenteric mast cell degranulation, as well as oxidative stress, in BAL fluid. In addition, we determined MIP, MEP, and mucociliary transport (in vivo, as well as tracheal contractility response (in vitro. Results: In comparison with the control group, the passive smoking group showed a significant increase in mast cell degranulation (19.75 ± 3.77% vs. 42.53 ± 0.42%; p < 0.001 and in the levels of reduced glutathione (293.9 ± 19.21 vs. 723.7 ± 67.43 nM/g of tissue; p < 0.05; as well as a significant reduction in mucociliary clearance (p < 0.05, which caused significant changes in pulmonary function (in MIP and MEP; p < 0.05 for both and airway hyperreactivity. Conclusions: Passive inhalation of cigarette smoke caused significant increases in mast cell degranulation and oxidative stress. This inflammatory process seems to influence the decrease in mucociliary transport and to cause changes in pulmonary function, leading to tracheal hyperreactivity.

  19. Dysrhythmias of the respiratory oscillator

    Paydarfar, David; Buerkel, Daniel M.

    1995-03-01

    Breathing is regulated by a central neural oscillator that produces rhythmic output to the respiratory muscles. Pathological disturbances in rhythm (dysrhythmias) are observed in the breathing pattern of children and adults with neurological and cardiopulmonary diseases. The mechanisms responsible for genesis of respiratory dysrhythmias are poorly understood. The present studies take a novel approach to this problem. The basic postulate is that the rhythm of the respiratory oscillator can be altered by a variety of stimuli. When the oscillator recovers its rhythm after such perturbations, its phase may be reset relative to the original rhythm. The amount of phase resetting is dependent upon stimulus parameters and the level of respiratory drive. The long-range hypothesis is that respiratory dysrhythmias can be induced by stimuli that impinge upon or arise within the respiratory oscillator with certain combinations of strength and timing relative to the respiratory cycle. Animal studies were performed in anesthetized or decerebrate preparations. Neural respiratory rhythmicity is represented by phrenic nerve activity, allowing use of open-loop experimental conditions which avoid negative chemical feedback associated with changes in ventilation. In animal experiments, respiratory dysrhythmias can be induced by stimuli having specific combinations of strength and timing. Newborn animals readily exhibit spontaneous dysrhythmias which become more prominent at lower respiratory drives. In human subjects, swallowing was studied as a physiological perturbation of respiratory rhythm, causing a pattern of phase resetting that is characterized topologically as type 0. Computational studies of the Bonhoeffer-van der Pol (BvP) equations, whose qualitative behavior is representative of many excitable systems, supports a unified interpretation of these experimental findings. Rhythmicity is observed when the BvP model exhibits recurrent periods of excitation alternating with

  20. Reactor Subsystem Simulation for Nuclear Hybrid Energy Systems

    Shannon Bragg-Sitton; J. Michael Doster; Alan Rominger

    2012-09-01

    Preliminary system models have been developed by Idaho National Laboratory researchers and are currently being enhanced to assess integrated system performance given multiple sources (e.g., nuclear + wind) and multiple applications (i.e., electricity + process heat). Initial efforts to integrate a Fortran-based simulation of a small modular reactor (SMR) with the balance of plant model have been completed in FY12. This initial effort takes advantage of an existing SMR model developed at North Carolina State University to provide initial integrated system simulation for a relatively low cost. The SMR subsystem simulation details are discussed in this report.

  1. YnfA , a SMR family efflux pump is abundant in Escherichia coli isolates from urinary infection

    S K Sarkar

    2015-01-01

    Full Text Available A quantitative study was undertaken to determine the expression level of different efflux pumps in multi-drug-resistant (MDR Escherichia coli isolates from urinary infection. We have determined the presence of different efflux pumps and measured the expression level of tolC, mdfA, norE and ynfA genes among 48 isolates by quantitative real-time PCR. The expression level of tolC and ynfA was constantly high and observed among 75-80% of isolates, whereas mdfA and norE were expressed occasionally. Our findings suggest that ynfA, a new SMR efflux pump gene family member increases the antibiotics′ resistance in E. coli.

  2. Respiratory problems in foals.

    Beech, J

    1985-04-01

    Despite major advances in our knowledge and ability to treat respiratory diseases in neonatal foals, neonatal respiratory medicine is still in its infancy. It is hoped that this article may serve as a guideline for diagnosis and treatment. Specific antibiotic regimens and emergency procedures are covered in other articles in this symposium. Because management factors play a critical role in the pathogenesis of respiratory disease, education of clients as to their importance would help both prophylactically and therapeutically. The necessity of very careful monitoring of neonates, which is critical to early detection of disease, should be stressed. As respiratory diseases can be fulminant and rapidly fatal, it is imperative not to delay diagnosis and therapy. Thorough examination and implementation of appropriate diagnostic techniques, as well as prompt early referral to a more sophisticated facility when indicated, would prevent many deaths. Although sophisticated support systems are vital for survival of some of these foals, good basic intensive nursing care combined with selection of appropriate drug therapy very early in the course of the disease is all that many foals require and can significantly improve survival rates.

  3. Update on CNSC's readiness to regulate projects proposing the use of Small Modular Reactors (SMR)

    De Vos, M.; Lee, K.

    2014-01-01

    Over the past few years, Canadian Nuclear Security Commission (CNSC)staff have been working to identify and understand key regulatory and technical issues that may be encountered in Small Modular Reactor (SMR) deployment scenarios in Canada. This work is considered necessary not only to be ready to engage with vendors and utilities in technical and licensing discussions, but also to prepare to disseminate objective scientific, technical and regulatory information to the public. Beyond size differences, SMRs are reactor-based facilities. The main finding from CNSC's work-to-date is that most, if not all, of the regulatory issues to be addressed from a Canadian perspective are due to the alternate or novel approaches that proponents of SMRs are proposing and that present uncertainties from the perspective of proven technology or public acceptance. These uncertainties represent risks that need to be mitigated by proponents before the environmental assessment and licensing processes are initiated. Examples of alternate or novel approaches include, but are not limited to: non-traditional siting scenarios (remote regions, near industrial facilities, in urban areas); increased use of physical design measures to reduce the need for security personnel; fleet-based regional emergency planning and response; design specific passive design features; and, remote operation of the facility This paper covers two main themes: 1. CNSC staff have made significant progress in the ongoing characterization of key regulatory and licensing issues that may emerge in deployment of both large and / or small SMRs in Canada. This work informs CNSC’s regulatory framework activities. 2. Many regulatory framework development activities (e.g. REGDOCs) have either already accounted for SMR concepts in the development of requirements and guidance or are planning to do so. This includes taking into account the ability to use a graded approach. (author)

  4. The soluble mannose receptor (sMR) is elevated in alcoholic liver disease and associated with disease severity, portal hypertension, and mortality in cirrhosis patients

    Sandahl, Thomas Damgaard; Støy, Sidsel Hyldgaard; Laursen, Tea Lund

    2017-01-01

    BACKGROUND AND AIMS: Hepatic macrophages (Kupffer cells) are involved in the immunopathology of alcoholic liver disease (ALD). The mannose receptor (MR, CD206), expressed primarily by macrophages, mediates endocytosis, antigen presentation and T-cell activation. A soluble form, sMR, has recently ...... level predicts portal hypertension and long-term mortality in AC patients....... and long-term (4 years) in AC patients. We measured plasma sMR by ELISA. RESULTS: Median sMR concentrations were significantly elevated in AH 1.32(IQR:0.69) and AC 0.46(0.5) compared to HC 0.2(0.06) mg/L; pportal...... hypertension (HVPG ≥10 mmHg) with an area under the Receiver Operator Characteristics curve of 0.86 and a high sMR cut-off (>0.43 mg/l) was associated with increased mortality (p = 0.005). CONCLUSION: The soluble mannose receptor is elevated in alcoholic liver disease, especially in patients with AH. Its blood...

  5. The soluble mannose receptor (sMR) is elevated in alcoholic liver disease and associated with disease severity, portal hypertension, and mortality in cirrhosis patients

    Sandahl, Thomas Damgaard; Støy, Sidsel Hyldgaard; Laursen, Tea Lund

    2017-01-01

    Background and aims Hepatic macrophages (Kupffer cells) are involved in the immunopathology of alcoholic liver disease (ALD). The mannose receptor (MR, CD206), expressed primarily by macrophages, mediates endocytosis, antigen presentation and T-cell activation. A soluble form, sMR, has recently b...... level predicts portal hypertension and long-term mortality in AC patients....... and long-term (4 years) in AC patients. We measured plasma sMR by ELISA. Results Median sMR concentrations were significantly elevated in AH 1.32(IQR:0.69) and AC 0.46 (0.5) compared to HC 0.2(0.06) mg/L; pportal...... hypertension (HVPG ≥10 mmHg) with an area under the Receiver Operator Characteristics curve of 0.86 and a high sMR cut-off (>0.43 mg/l) was associated with increased mortality (p = 0.005). Conclusion The soluble mannose receptor is elevated in alcoholic liver disease, especially in patients with AH. Its blood...

  6. Identification and characterization of PhbF: a DNA binding protein with regulatory role in the PHB metabolism of Herbaspirillum seropedicae SmR1.

    Kadowaki, Marco A S; Müller-Santos, Marcelo; Rego, Fabiane G M; Souza, Emanuel M; Yates, Marshall G; Monteiro, Rose A; Pedrosa, Fabio O; Chubatsu, Leda S; Steffens, Maria B R

    2011-10-14

    Herbaspirillum seropedicae SmR1 is a nitrogen fixing endophyte associated with important agricultural crops. It produces polyhydroxybutyrate (PHB) which is stored intracellularly as granules. However, PHB metabolism and regulatory control is not yet well studied in this organism. In this work we describe the characterization of the PhbF protein from H. seropedicae SmR1 which was purified and characterized after expression in E. coli. The purified PhbF protein was able to bind to eleven putative promoters of genes involved in PHB metabolism in H. seropedicae SmR1. In silico analyses indicated a probable DNA-binding sequence which was shown to be protected in DNA footprinting assays using purified PhbF. Analyses using lacZ fusions showed that PhbF can act as a repressor protein controlling the expression of PHB metabolism-related genes. Our results indicate that H. seropedicae SmR1 PhbF regulates expression of phb-related genes by acting as a transcriptional repressor. The knowledge of the PHB metabolism of this plant-associated bacterium may contribute to the understanding of the plant-colonizing process and the organism's resistance and survival in planta.

  7. Identification and characterization of PhbF: A DNA binding protein with regulatory role in the PHB metabolism of Herbaspirillum seropedicae SmR1

    Pedrosa Fabio O

    2011-10-01

    Full Text Available Abstract Background Herbaspirillum seropedicae SmR1 is a nitrogen fixing endophyte associated with important agricultural crops. It produces polyhydroxybutyrate (PHB which is stored intracellularly as granules. However, PHB metabolism and regulatory control is not yet well studied in this organism. Results In this work we describe the characterization of the PhbF protein from H. seropedicae SmR1 which was purified and characterized after expression in E. coli. The purified PhbF protein was able to bind to eleven putative promoters of genes involved in PHB metabolism in H. seropedicae SmR1. In silico analyses indicated a probable DNA-binding sequence which was shown to be protected in DNA footprinting assays using purified PhbF. Analyses using lacZ fusions showed that PhbF can act as a repressor protein controlling the expression of PHB metabolism-related genes. Conclusions Our results indicate that H. seropedicae SmR1 PhbF regulates expression of phb-related genes by acting as a transcriptional repressor. The knowledge of the PHB metabolism of this plant-associated bacterium may contribute to the understanding of the plant-colonizing process and the organism's resistance and survival in planta.

  8. Effects of High Altitude on Sleep and Respiratory System and Theirs Adaptations

    Turhan San

    2013-01-01

    Full Text Available High-altitude (HA environments have adverse effects on the normal functioning body of people accustomed to living at low altitudes because of the change in barometric pressure which causes decrease in the amount of oxygen leading to hypobaric hypoxia. Sustained exposure to hypoxia has adverse effects on body weight, muscle structure and exercise capacity, mental functioning, and sleep quality. The most important step of acclimatization is the hyperventilation which is achieved by hypoxic ventilatory response of the peripheral chemoreceptors. Hyperventilation results in increase in arterial carbondioxide concentration. Altitude also affects sleep and cardiac output, which is the other determinant of oxygen delivery. Upon initial exposure to HA, the resting pulse rate increases rapidly, but with acclimatization, heart rate and cardiac output tend to fall. Another important component that leads to decrease in cardiac output is the reduction in the stroke volume with acclimatization. During sleep at HA, the levels of CO2 in the blood can drop very low and this can switch off the drive to breathe. Only after the body senses a further drop in O2 levels breathing is started again. Periodic breathing is thought to result from instability in the control system through the hypoxic drive or the response to CO2.

  9. Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

    Tachibana, Hidenobu; Kitamura, Nozomi; Ito, Yasushi; Kawai, Daisuke; Nakajima, Masaru; Tsuda, Akihisa; Shiizuka, Hisao

    2011-01-01

    Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 ± 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 ± 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 ± 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 ± 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The

  10. Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period

    Nava Pat

    2011-03-01

    Full Text Available Abstract Background Is Impulse Oscillometry System (IOS a valuable tool to measure respiratory system function in Children? Asthma (A is the most prevalent chronic respiratory disease in children. Therefore, early and accurate assessment of respiratory function is of tremendous clinical interest in diagnosis, monitoring and treatment of respiratory conditions in this subpopulation. IOS has been successfully used to measure lung function in children with a high degree of sensitivity and specificity to small airway impairments (SAI and asthma. IOS measures of airway function and equivalent electrical circuit models of the human respiratory system have been developed to quantify the severity of these conditions. Previously, we have evaluated several known respiratory models based on the Mead's model and more parsimonious versions based on fitting IOS data known as extended RIC (eRIC and augmented RIC (aRIC models have emerged, which offer advantages over earlier models. Methods IOS data from twenty-six children were collected and compared during pre-bronchodilation (pre-B and post- bronchodilation (post-B conditions over a period of 2 years. Results and Discussion Are the IOS and model parameters capable of differentiating between healthy children and children with respiratory system distress? Children were classified into two main categories: Healthy (H and Small Airway-Impaired (SAI. The IOS measures and respiratory model parameters analyzed differed consistently between H and SAI children. SAI children showed smaller trend of "growth" and larger trend of bronchodilator responses than H children. The two model parameters: peripheral compliance (Cp and peripheral resistance (Rp tracked IOS indices of small airway function well. Cp was a more sensitive index than Rp. Both eRIC and aRIC Cps and the IOS Reactance Area, AX, (also known as the "Goldman Triangle" showed good correlations. Conclusions What are the most useful IOS and model parameters? In

  11. Neonatal respiratory distress syndrome

    Hyaline membrane disease (HMD); Infant respiratory distress syndrome; Respiratory distress syndrome in infants; RDS - infants ... improves slowly after that. Some infants with severe respiratory distress syndrome will die. This most often occurs ...

  12. SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

    Shiinoki, T; Hanazawa, H; Shibuya, K [Yamaguchi University, Ube, Yamaguchi (Japan); Kawamura, S; Koike, M; Yuasa, Y; Uehara, T; Fujimoto, K [Yamaguchi University Hospital, Ube, Yamaguchi (Japan)

    2016-06-15

    Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of the lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.

  13. Nanotechnology in respiratory medicine.

    Omlor, Albert Joachim; Nguyen, Juliane; Bals, Robert; Dinh, Quoc Thai

    2015-05-29

    Like two sides of the same coin, nanotechnology can be both boon and bane for respiratory medicine. Nanomaterials open new ways in diagnostics and treatment of lung diseases. Nanoparticle based drug delivery systems can help against diseases such as lung cancer, tuberculosis, and pulmonary fibrosis. Moreover, nanoparticles can be loaded with DNA and act as vectors for gene therapy in diseases like cystic fibrosis. Even lung diagnostics with computer tomography (CT) or magnetic resonance imaging (MRI) profits from new nanoparticle based contrast agents. However, the risks of nanotechnology also have to be taken into consideration as engineered nanomaterials resemble natural fine dusts and fibers, which are known to be harmful for the respiratory system in many cases. Recent studies have shown that nanoparticles in the respiratory tract can influence the immune system, can create oxidative stress and even cause genotoxicity. Another important aspect to assess the safety of nanotechnology based products is the absorption of nanoparticles. It was demonstrated that the amount of pulmonary nanoparticle uptake not only depends on physical and chemical nanoparticle characteristics but also on the health status of the organism. The huge diversity in nanotechnology could revolutionize medicine but makes safety assessment a challenging task.

  14. Evaluation of a Computer-aided Lung Auscultation System for Diagnosis of Bovine Respiratory Disease in Feedlot Cattle.

    Mang, A V; Buczinski, S; Booker, C W; Timsit, E

    2015-01-01

    A computer-aided lung auscultation (CALA) system was recently developed to diagnose bovine respiratory disease (BRD) in feedlot cattle. To determine, in a case-control study, the level of agreement between CALA and veterinary lung auscultation and to evaluate the sensitivity (Se) and specificity (Sp) of CALA to diagnose BRD in feedlot cattle. A total of 561 Angus cross-steers (initial body weight = 246 ± 45 kg) were observed during the first 50 day after entry to a feedlot. Case-control study. Steers with visual signs of BRD identified by pen checkers were examined by a veterinarian, including lung auscultation using a conventional stethoscope and CALA that produced a lung score from 1 (normal) to 5 (chronic). For each steer examined for BRD, 1 apparently healthy steer was selected as control and similarly examined. Agreement between CALA and veterinary auscultation was assessed by kappa statistic. CALA's Se and Sp were estimated using Bayesian latent class analysis. Of the 561 steers, 35 were identified with visual signs of BRD and 35 were selected as controls. Comparison of veterinary auscultation and CALA (using a CALA score ≥2 as a cut off) revealed a substantial agreement (kappa = 0.77). Using latent class analysis, CALA had a relatively high Se (92.9%; 95% credible interval [CI] = 0.71-0.99) and Sp (89.6%; 95% CI = 0.64-0.99) for diagnosing BRD compared with pen checking. CALA had good diagnostic accuracy (albeit with a relatively wide CI). Its use in feedlots could increase the proportion of cattle accurately diagnosed with BRD. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  15. Lungs and Respiratory System

    ... Wrong Print en español Los pulmones y el sistema respiratorio Whether you're wide awake and getting ... of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on TeensHealth® is for ...

  16. Verification of respiratory-gated radiotherapy with new real-time tumour-tracking radiotherapy system using cine EPID images and a log file

    Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko

    2017-02-01

    A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were  ⩽3 mm and  ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.

  17. Verification of respiratory-gated radiotherapy with new real-time tumour-tracking radiotherapy system using cine EPID images and a log file.

    Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko

    2017-02-21

    A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were  ⩽3 mm and  ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.

  18. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    Koujalagi, V; Semple, S; Ayres, J G; Ramesh, S L; Gunarathne, G P P

    2009-01-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  19. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    Koujalagi, V.; Ramesh, S. L.; Gunarathne, G. P. P.; Semple, S.; Ayres, J. G.

    2009-02-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  20. Respiratory monitor system for 4D CT image acquisition based on accelerometer. Design and implementation; Sistema de monitorizacion respiratoria para adquisicion de imagenes 4D de TC basado en un acelerometro. Diseno e implementacion

    Llorente Manso, M.; Vivela Serrano, S.; Viera Jorge, J. C.; Garran del Rio, C.; Ferrer Gracia, C.; Carballo Gonzalez, N.

    2013-07-01

    The use of 4D CT images in Radiotherapy planning is increasing. Some commercial systems use abdominal movement to correlate images with respiratory phase. An in-house developed system based on an accelerometer to register patient's abdominal movement and a software to group 4D images in their corresponding respiratory phase is presented. A phantom test evaluates the capacity of the system to properly identify respiratory phases. A volunteers study compares breathing curves acquired by the accelerometer with those obtained using a commercial system. In the phantom images, maximum difference between real and calculated phase is 0.2 s. In the volunteer study, position of the curve maxima found by both systems differs, on average, around 2% (SD=2%) of the respiratory cycle period when volunteer's breathing is regular. Only when breathe is very irregular, differences of up to 10% in the phase assignment are found. (Author)

  1. Creatine and creatine pyruvate reduce hypoxia-induced effects on phrenic nerve activity in the juvenile mouse respiratory system.

    Scheer, Monika; Bischoff, Anna M; Kruzliak, Peter; Opatrilova, Radka; Bovell, Douglas; Büsselberg, Dietrich

    2016-08-01

    Adequate concentrations of ATP are required to preserve physiological cell functions and protect tissue from hypoxic damage. Decreased oxygen concentration results in ATP synthesis relying increasingly on the presence of phosphocreatine. The lack of ATP through hypoxic insult to neurons that generate or regulate respiratory function, would lead to the cessation of breathing (apnea). It is not clear whether creatine plays a role in maintaining respiratory phrenic nerve (PN) activity during hypoxic challenge. The aim of the study was to test the effects of exogenously applied creatine or creatine pyruvate in maintaining PN induced respiratory rhythm against the deleterious effects of severe hypoxic insult using Working Heart-Brainstem (WHB) preparations of juvenile Swiss type mice. WHB's were perfused with control perfusate or perfusate containing either creatine [100μM] or creatine pyruvate [100μM] prior to hypoxic challenge and PN activity recorded throughout. Results showed that severe hypoxic challenge resulted in an initial transient increase in PN activity, followed by a reduction in that activity leading to respiratory apnea. The results demonstrated that perfusing the WHB preparation with creatine or creatine pyruvate, significantly reduced the onset of apnea compared to control conditions, with creatine pyruvate being the more effective substance. Overall, creatine and creatine pyruvate each produced time-dependent degrees of protection against severe hypoxic-induced disturbances of PN activity. The underlying protective mechanisms are unknown and need further investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  3. Long-term effects of mustard gas on respiratory system of Iranian veterans after Iraq-Iran war: a review

    Razavi Seyed Mansour

    2013-06-01

    Full Text Available 【Abstract】To review long-term respiratory effects of mustard gas on Iranian veterans having undergone Iraq-Iran war. Electronic databases of Scopus, Medline, ISI, IranMedex, and Irandoc sites were searched. We accepted articles published in scientific journals as a quality criterion. The main pathogenic factors are free radical mediators. Preva-lence of pulmonary involvement is approximately 42.5%. The most common complaints are cough and dyspnea. Major respiratory complications are chronic obstructive pulmo-nary disease, bronchiectasis, and asthma. Spirometry re-sults can reveal restrictive and obstructive pulmonary disease. Plain chest X-ray does not help in about 50% of lung diseases. High-resolution CT of the lung is the best modality for diagnostic assessment of parenchymal lung and bronchi. There is no definite curative treatment for mus-tard lung. The effective treatment regimens consist of oxy-gen administration, use of vaporized moist air, respiratory physiotherapy, administration of mucolytic agents, bronchodilators, corticosteroids, and long-acting beta-2 agonists, antioxidants, surfactant, magnesium ions, thera-peutic bronchoscopy, laser therapy, placement of respira-tory stents, early tracheostomy in laryngospasm, and ulti-mately lung transplantation. High-resolution CT of the lung is the most accurate modality for the evaluation of the lung parenchyma and bronchi. The treatment efficacy of patients exposed to mustard gas depends on patient conditions (acute or chronic, upper or lower respiratory tract involvement. There are various treatment protocols, but unfortunately none of them is definitely curable. Key words: Lung injury; Chemical warfare; Mustard gas

  4. Middle East Respiratory Syndrome

    2014-07-07

    This podcast discusses Middle East Respiratory Syndrome, or MERS, a viral respiratory illness caused by Middle East Respiratory Syndrome Coronavirus—MERS-CoV.  Created: 7/7/2014 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 7/7/2014.

  5. Failure probabilities of SiC clad fuel during a LOCA in public acceptable simple SMR (PASS)

    Lee, Youho, E-mail: euo@kaist.ac.kr; Kim, Ho Sik, E-mail: hskim25@kaist.ac.kr; NO, Hee Cheon, E-mail: hcno@kaist.ac.kr

    2015-10-15

    Highlights: • Graceful operating conditions of SMRs markedly lower SiC cladding stress. • Steady-state fracture probabilities of SiC cladding is below 10{sup −7} in SMRs. • PASS demonstrates fuel coolability (T < 1300 °C) with sole radiation in LOCA. • SiC cladding failure probabilities of PASS are ∼10{sup −2} in LOCA. • Cold gas gap pressure controls SiC cladding tensile stress level in LOCA. - Abstract: Structural integrity of SiC clad fuels in reference Small Modular Reactors (SMRs) (NuScale, SMART, IRIS) and a commercial pressurized water reactor (PWR) are assessed with a multi-layered SiC cladding structural analysis code. Featured with low fuel pin power and temperature, SMRs demonstrate markedly reduced incore-residence fracture probabilities below ∼10{sup −7}, compared to those of commercial PWRs ∼10{sup −6}–10{sup −1}. This demonstrates that SMRs can serve as a near-term deployment fit to SiC cladding with a sound management of its statistical brittle fracture. We proposed a novel SMR named Public Acceptable Simple SMR (PASS), which is featured with 14 × 14 assemblies of SiC clad fuels arranged in a square ring layout. PASS aims to rely on radiative cooling of fuel rods during a loss of coolant accident (LOCA) by fully leveraging high temperature tolerance of SiC cladding. An overarching assessment of SiC clad fuel performance in PASS was conducted with a combined methodology—(1) FRAPCON-SiC for steady-state performance analysis of PASS fuel rods, (2) computational fluid dynamics code FLUENT for radiative cooling rate of fuel rods during a LOCA, and (3) multi-layered SiC cladding structural analysis code with previously developed SiC recession correlations under steam environments for both steady-state and LOCA. The results show that PASS simultaneously maintains desirable fuel cooling rate with the sole radiation and sound structural integrity of fuel rods for over 36 days of a LOCA without water supply. The stress level of

  6. Modeling acute respiratory illness during the 2007 San Diego wildland fires using a coupled emissions-transport system and generalized additive modeling.

    Thelen, Brian; French, Nancy H F; Koziol, Benjamin W; Billmire, Michael; Owen, Robert Chris; Johnson, Jeffrey; Ginsberg, Michele; Loboda, Tatiana; Wu, Shiliang

    2013-11-05

    A study of the impacts on respiratory health of the 2007 wildland fires in and around San Diego County, California is presented. This study helps to address the impact of fire emissions on human health by modeling the exposure potential of proximate populations to atmospheric particulate matter (PM) from vegetation fires. Currently, there is no standard methodology to model and forecast the potential respiratory health effects of PM plumes from wildland fires, and in part this is due to a lack of methodology for rigorously relating the two. The contribution in this research specifically targets that absence by modeling explicitly the emission, transmission, and distribution of PM following a wildland fire in both space and time. Coupled empirical and deterministic models describing particulate matter (PM) emissions and atmospheric dispersion were linked to spatially explicit syndromic surveillance health data records collected through the San Diego Aberration Detection and Incident Characterization (SDADIC) system using a Generalized Additive Modeling (GAM) statistical approach. Two levels of geographic aggregation were modeled, a county-wide regional level and division of the county into six sub regions. Selected health syndromes within SDADIC from 16 emergency departments within San Diego County relevant for respiratory health were identified for inclusion in the model. The model captured the variability in emergency department visits due to several factors by including nine ancillary variables in addition to wildfire PM concentration. The model coefficients and nonlinear function plots indicate that at peak fire PM concentrations the odds of a person seeking emergency care is increased by approximately 50% compared to non-fire conditions (40% for the regional case, 70% for a geographically specific case). The sub-regional analyses show that demographic variables also influence respiratory health outcomes from smoke. The model developed in this study allows a

  7. [Mortality from respiratory diseases in the provinces of Apulia Region (Southern Italy) from 1933 to 2010].

    Montinari, Maria Rosa; Gianicolo, Emilio Antonio Luca; Vigotti, Maria Angela

    2016-01-01

    OBIETTIVI: valutare l'andamento temporale della mortalità per patologie respiratorie nelle province pugliesi utilizzando dati omogenei per fonte e metodologia di calcolo. DISEGNO: analisi ecologica storica degli andamenti temporali di mortalità per tumori e patologie dell'apparato respiratorio nelle province pugliesi, in Puglia e nelle ripartizioni geografiche italiane dal 1933 al 2010. SETTING E PARTECIPANTI: i dati di mortalità e le popolazioni residenti sono di fonte Istat. Sono state esaminate tutte le cause di decesso, il tumore della laringe, il tumore del polmone, l'insieme dei tumori respiratori, la bronchite, la polmonite e la broncopolmonite considerate congiuntamente, e l'insieme delle patologie respiratorie. Le analisi sono disaggregate per sesso dal 1969. PRINCIPALI MISURE DI OUTCOME: rapporti standardizzati di mortalità (SMR%) in riferimento all'Italia, con intervalli di confidenza al 95%, e tassi di mortalità standardizzati col metodo diretto (TSD ) in riferimento alla popolazione standard europea. RISULTATI: dal 1933 al 2010, i TSD per tumori respiratori e per bronchiti diminuiscono in tutte le aree analizzate. Tuttavia, nelle province di Taranto, Brindisi e Lecce, l'SMR% per tumori respiratori, inferiore al riferimento nazionale fino agli anni Sessanta, si allinea (a Brindisi) e supera (a Lecce e Taranto) il riferimento negli anni successivi. Nelle province di Foggia e Bari il numero dei decessi per tumore del polmone è costantemente inferiore all'atteso. CONCLUSIONI: la ricostruzione storica e l'analisi dei trend temporali di mortalità dal 1933 al 2010 mostrano alcune criticità sanitarie in periodi specifici. L'elaborazione dei dati di mortalità per un arco temporale di circa 80 anni ha messo in evidenza la maggiore rilevanza di queste criticità con l'avvio dello sviluppo industriale.

  8. Immediate and long-term effects in the hematopoietic system and the morphology of the respiratory system in experimental animals under chronic combined action of external gamma exposure and inhalation exposure.

    Tatarkin, Sergey; Moukhamedieva, Lana; Aleksandr, Shafirkin; Barantseva, Maria; Ivanova, Svetlana

    The need to solve hygiene problems valuation of environmental factors in the implementation of the projected manned interplanetary missions, determined the relevance of studying the effect of external gamma-irradiation with inhalation of mixtures of chemicals on the parameters of major critical body systems: hematopoiesis and respiratory (morphological and morphometric parameters) in the short and long periods. The study conducted on 504 male mice F1 (CBA × C57BL6) under chronic fractional gamma-irradiation (within 10 weeks at a total dose 350sGr) and then under inhalation by mixtures of chemicals in low concentrations. Duration of the experiment (124 days) and 90 -day recovery period. Displaying adaptive reorganization in hematopoietic system, which was characterized by a tension of regulatory systems of animals and by a proliferation of bone marrow cells and by dynamic changes in amount of lymphoid cells in peripheral blood, elevated levels of the antioxidant activity of red blood cells, and morphological manifestations of "incomplete recovery " of the spleen, which are retained in the recovery period. Morphological changes in the respiratory organs of animals testified about immunogenesis activation and development of structural changes as a chronic inflammatory process. Increase of fibrous connective tissue in the walls of the trachea, bronchus and lung, against reduction of loose fibrous connective tissue (more pronounced in respiratory parts of the respiratory system) in experimental animals, which may indicate a reduction of the functional reserves of the body and increase the risk of adverse long-term effects.

  9. dbSMR: a novel resource of genome-wide SNPs affecting microRNA mediated regulation

    Hariharan Manoj

    2009-04-01

    Full Text Available Abstract Background MicroRNAs (miRNAs regulate several biological processes through post-transcriptional gene silencing. The efficiency of binding of miRNAs to target transcripts depends on the sequence as well as intramolecular structure of the transcript. Single Nucleotide Polymorphisms (SNPs can contribute to alterations in the structure of regions flanking them, thereby influencing the accessibility for miRNA binding. Description The entire human genome was analyzed for SNPs in and around predicted miRNA target sites. Polymorphisms within 200 nucleotides that could alter the intramolecular structure at the target site, thereby altering regulation were annotated. Collated information was ported in a MySQL database with a user-friendly interface accessible through the URL: http://miracle.igib.res.in/dbSMR. Conclusion The database has a user-friendly interface where the information can be queried using either the gene name, microRNA name, polymorphism ID or transcript ID. Combination queries using 'AND' or 'OR' is also possible along with specifying the degree of change of intramolecular bonding with and without the polymorphism. Such a resource would enable researchers address questions like the role of regulatory SNPs in the 3' UTRs and population specific regulatory modulations in the context of microRNA targets.

  10. Graphene as an active virtually massless top electrode for RF solidly mounted bulk acoustic wave (SMR-BAW) resonators

    Knapp, Marius; Hoffmann, René; Lebedev, Vadim; Cimalla, Volker; Ambacher, Oliver

    2018-03-01

    Mechanical and electrical losses induced by an electrode material greatly influence the performance of bulk acoustic wave (BAW) resonators. Graphene as a conducting and virtually massless 2D material is a suitable candidate as an alternative electrode material for BAW resonators which reduces electrode induced mechanical losses. In this publication we show that graphene acts as an active top electrode for solidly mounted BAW resonators (BAW-SMR) at 2.1 GHz resonance frequency. Due to a strong decrease of mass loading and its remarkable electronic properties, graphene demonstrates its ability as an ultrathin conductive layer. In our experiments we used an optimized graphene wet transfer on aluminum nitride-based solidly mounted resonator devices. We achieved more than a triplication of the resonator’s quality factor Q and a resonance frequency close to an ‘unloaded’ resonator without metallization. Our results reveal the direct influence of both, the graphene quality and the graphene contacting via metal structures, on the performance characteristic of a BAW resonator. These findings clearly show the potential of graphene in minimizing mechanical losses due to its virtually massless character. Moreover, they highlight the advantages of graphene and other 2D conductive materials for alternative electrodes in electroacoustic resonators for radio frequency applications.

  11. Influenza hospitalization epidemiology from a severe acute respiratory infection surveillance system in Jordan, January 2008-February 2014.

    Al-Abdallat, Mohammad; Dawson, Patrick; Haddadin, Aktham Jeries; El-Shoubary, Waleed; Dueger, Erica; Al-Sanouri, Tarek; Said, Mayar M; Talaat, Maha

    2016-03-01

    Acute respiratory infections (ARIs) are a major cause of morbidity and mortality worldwide. Influenza typically contributes substantially to the burden of ARI, but only limited data are available on influenza activity and seasonality in Jordan. Syndromic case definitions were used to identify individuals with severe acute respiratory infections (SARI) admitted to four sentinel hospitals in Jordan. Demographic and clinical data were collected. Nasopharyngeal and oropharyngeal swabs were tested for influenza using real-time reverse transcription polymerase chain reaction and typed as influenza A or B, with influenza A further subtyped. From January 2008-February 2014, 2891 SARI cases were tested for influenza, and 257 (9%) were positive. While 73% of all SARI cases were under 5 years of age, only 57% of influenza-positive cases were under 5 years of age. Eight (3%) influenza-positive cases died. An annual seasonal pattern of influenza activity was observed. The proportion of influenza-positive cases peaked during November-January (14-42%) in the non-pandemic years. Influenza is associated with substantial morbidity and mortality in Jordan. The seasonal pattern of influenza aligns with known Northern Hemisphere seasonality. Further characterization of the clinical and financial burden of influenza in Jordan will be critical in supporting decisions regarding disease control activities. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  12. Replication of elite music performance enhancement following alpha/theta neurofeedback and application to novice performance and improvisation with SMR benefits.

    Gruzelier, J H; Holmes, P; Hirst, L; Bulpin, K; Rahman, S; van Run, C; Leach, J

    2014-01-01

    Alpha/theta (A/T) and sensory-motor rhythm (SMR) neurofeedback were compared in university instrumentalists who were novice singers with regard to prepared and improvised instrumental and vocal performance in three music domains: creativity/musicality, technique and communication/presentation. Only A/T training enhanced advanced playing seen in all three domains by expert assessors and validated by correlations with learning indices, strongest with Creativity/Musicality as shown by Egner and Gruzelier (2003). Here A/T gains extended to novice performance - prepared vocal, improvised vocal and instrumental - and were recognised by a lay audience who judged the prepared folk songs. SMR learning correlated positively with Technical Competence and Communication in novice performance, in keeping with SMR neurofeedback's known impact on lower-order processes such as attention, working memory and psychomotor skills. The importance of validation through learning indices was emphasised in the interpretation of neurofeedback outcome. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Genomic comparison of the endophyte Herbaspirillum seropedicae SmR1 and the phytopathogen Herbaspirillum rubrisubalbicans M1 by suppressive subtractive hybridization and partial genome sequencing.

    Monteiro, Rose A; Balsanelli, Eduardo; Tuleski, Thalita; Faoro, Helison; Cruz, Leonardo M; Wassem, Roseli; de Baura, Valter A; Tadra-Sfeir, Michelle Z; Weiss, Vinícius; DaRocha, Wanderson D; Muller-Santos, Marcelo; Chubatsu, Leda S; Huergo, Luciano F; Pedrosa, Fábio O; de Souza, Emanuel M

    2012-05-01

    Herbaspirillum rubrisubalbicans M1 causes the mottled stripe disease in sugarcane cv. B-4362. Inoculation of this cultivar with Herbaspirillum seropedicae SmR1 does not produce disease symptoms. A comparison of the genomic sequences of these closely related species may permit a better understanding of contrasting phenotype such as endophytic association and pathogenic life style. To achieve this goal, we constructed suppressive subtractive hybridization (SSH) libraries to identify DNA fragments present in one species and absent in the other. In a parallel approach, partial genomic sequence from H. rubrisubalbicans M1 was directly compared in silico with the H. seropedicae SmR1 genome. The genomic differences between the two organisms revealed by SSH suggested that lipopolysaccharide and adhesins are potential molecular factors involved in the different phenotypic behavior. The cluster wss probably involved in cellulose biosynthesis was found in H. rubrisubalbicans M1. Expression of this gene cluster was increased in H. rubrisubalbicans M1 cells attached to the surface of maize root, and knockout of wssD gene led to decrease in maize root surface attachment and endophytic colonization. The production of cellulose could be responsible for the maize attachment pattern of H. rubrisubalbicans M1 that is capable of outcompeting H. seropedicae SmR1. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  14. SMR-CL, A Real-time Control Language for Mobile Robots

    Andersen, Nils Axel; Ravn, Ole

    2004-01-01

    The paper describes requirements and implementation of a tactical control lan¬guage for mobile robots. Emphasis is given to the real-time issues of the language especially the isolation of the hard real-time and the soft real-time layers of the mobile robot control system. The language may be used...

  15. Flexblue: an immersed SMR with a new and challenging nuclear paradigm

    Bugat, A.; Felten, P.; Lecomte, M.; Poimboeuf, J-M.; Briffod, F-X.; Perrier, S.

    2014-01-01

    NucAdvisor gives advice and provides DCNS with studies related to the Flexblue project since the beginning of the project. The present paper will summarize the main results out of technical aspects. The important potential market of SMRs after 2020 has been put in evidence by several studies around the world and also in France. The development of the whole Flexblue system requires an innovative approach which appears to be more stringent and important than the reactor by itself. The interests of an immersed module for nuclear safety will be discussed as well as some challenges related to public acceptance. Flexblue shows also an LCOE in the range of 100 Euro/MWh which structure will be presented and discussed. The licensing process for such a system requires a challenging new approach to be defined at a multinational level. Lastly we will give a brief status of the Flexblue project. (authors)

  16. The influence of dietary fatty acid composition on the respiratory and cardiovascular physiology of Adriatic sturgeon (Acipenser naccarii): a review

    McKenzie, DJ; Piraccini, G; Agnisola, C

    1999-01-01

    as 15% of dry feed weight), with an elevated content of highly unsaturated fatty acids of the co3 series (¿3 HUFA), had a significantly lower standard metabolic rate (SMR) and routine oxygen consumption (Mo2) than those fed a diet enriched with the same quantity of hydrogenated coconut oil......This paper reviews evidence that the fatty acid composition of dietary lipids influences the respiratory and cardiovascular physiology of Adriatic sturgeon {Acipenser naccarii) and, thereby, their tolerance of the stress of hypoxia. Sturgeon fed a commercial diet enriched in fish oil (menhaden oil...

  17. Respiratory monitoring with an acceleration sensor

    Ono, Tomohiro; Takegawa, Hideki; Ageishi, Tatsuya; Takashina, Masaaki; Numasaki, Hodaka; Matsumoto, Masao; Teshima, Teruki

    2011-01-01

    Respiratory gating radiotherapy is used to irradiate a local area and to reduce normal tissue toxicity. There are certain methods for the detection of tumor motions, for example, using internal markers or an external respiration signal. However, because some of these respiratory monitoring systems require special or expensive equipment, respiratory monitoring can usually be performed only in limited facilities. In this study, the feasibility of using an acceleration sensor for respiratory monitoring was evaluated. The respiratory motion was represented by means of a platform and measured five times with the iPod touch (registered) at 3, 4 and 5 s periods of five breathing cycles. For these three periods of the reference waveform, the absolute means ± standard deviation (SD) of displacement were 0.45 ± 0.34 mm, 0.33 ± 0.24 mm and 0.31 ± 0.23 mm, respectively. On the other hand, the corresponding absolute means ± SD for the periods were 0.04 ± 0.09 s, 0.04 ± 0.02 s and 0.06 ± 0.04 s. The accuracy of respiratory monitoring using the acceleration sensor was satisfactory in terms of the absolute means ± SD. Using the iPod touch (registered) for respiratory monitoring does not need special equipment and makes respiratory monitoring easier. For these reasons, this system is a viable alternative to other respiratory monitoring systems.

  18. The respiratory microbiome and respiratory infections

    Unger, Stefan A.; Bogaert, Debby

    2017-01-01

    Despite advances over the past ten years lower respiratory tract infections still comprise around a fifth of all deaths worldwide in children under five years of age with the majority in low- and middle-income countries. Known risk factors for severe respiratory infections and poor chronic

  19. Essential Genes for In Vitro Growth of the Endophyte Herbaspirillum seropedicae SmR1 as Revealed by Transposon Insertion Site Sequencing.

    Rosconi, Federico; de Vries, Stefan P W; Baig, Abiyad; Fabiano, Elena; Grant, Andrew J

    2016-11-15

    The interior of plants contains microorganisms (referred to as endophytes) that are distinct from those present at the root surface or in the surrounding soil. Herbaspirillum seropedicae strain SmR1, belonging to the betaproteobacteria, is an endophyte that colonizes crops, including rice, maize, sugarcane, and sorghum. Different approaches have revealed genes and pathways regulated during the interactions of H. seropedicae with its plant hosts. However, functional genomic analysis of transposon (Tn) mutants has been hampered by the lack of genetic tools. Here we successfully employed a combination of in vivo high-density mariner Tn mutagenesis and targeted Tn insertion site sequencing (Tn-seq) in H. seropedicae SmR1. The analysis of multiple gene-saturating Tn libraries revealed that 395 genes are essential for the growth of H. seropedicae SmR1 in tryptone-yeast extract medium. A comparative analysis with the Database of Essential Genes (DEG) showed that 25 genes are uniquely essential in H. seropedicae SmR1. The Tn mutagenesis protocol developed and the gene-saturating Tn libraries generated will facilitate elucidation of the genetic mechanisms of the H. seropedicae endophytic lifestyle. A focal point in the study of endophytes is the development of effective biofertilizers that could help to reduce the input of agrochemicals in croplands. Besides the ability to promote plant growth, a good biofertilizer should be successful in colonizing its host and competing against the native microbiota. By using a systematic Tn-based gene-inactivation strategy and massively parallel sequencing of Tn insertion sites (Tn-seq), it is possible to study the fitness of thousands of Tn mutants in a single experiment. We have applied the combination of these techniques to the plant-growth-promoting endophyte Herbaspirillum seropedicae SmR1. The Tn mutant libraries generated will enable studies into the genetic mechanisms of H. seropedicae-plant interactions. The approach that we

  20. Respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK): Initial clinical experience on an MRI-guided radiotherapy system.

    Han, Fei; Zhou, Ziwu; Du, Dongsu; Gao, Yu; Rashid, Shams; Cao, Minsong; Shaverdian, Narek; Hegde, John V; Steinberg, Michael; Lee, Percy; Raldow, Ann; Low, Daniel A; Sheng, Ke; Yang, Yingli; Hu, Peng

    2018-06-01

    To optimize and evaluate the respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK-4D-MRI) method in a 0.35 T MRI-guided radiotherapy (MRgRT) system. The study included seven patients with abdominal tumors treated on the MRgRT system. ROCK-4D-MRI and 2D-CINE, was performed immediately after one of the treatment fractions. Motion quantification based on 4D-MRI was compared with those based on 2D-CINE. The image quality of 4D-MRI was evaluated against 4D-CT. The gross tumor volumes (GTV) were defined based on individual respiratory phases of both 4D-MRI and 4D-CT and compared for their variability over the respiratory cycle. The motion measurements based on 4D-MRI matched well with 2D-CINE, with differences of 1.04 ± 0.52 mm in the superior-inferior and 0.54 ± 0.21 mm in the anterior-posterior directions. The image quality scores of 4D-MRI were significantly higher than 4D-CT, with better tumor contrast (3.29 ± 0.76 vs. 1.86 ± 0.90) and less motion artifacts (3.57 ± 0.53 vs. 2.29 ± 0.95). The GTVs were more consistent in 4D-MRI than in 4D-CT, with significantly smaller GTV variability (9.31 ± 4.58% vs. 34.27 ± 23.33%). Our study demonstrated the clinical feasibility of using the ROCK-4D-MRI to acquire high quality, respiratory motion-resolved 4D-MRI in a low-field MRgRT system. The 4D-MRI image could provide accurate dynamic information for radiotherapy treatment planning. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Respiratory Syncytial Virus

    ... with facebook share with twitter share with linkedin Respiratory Syncytial Virus (RSV) Credit: CDC This is the ... the United States. Why Is the Study of Respiratory Syncytial Virus (RSV) a Priority for NIAID? In ...

  2. Respiratory syncytial virus (RSV)

    RSV; Palivizumab; Respiratory syncytial virus immune globulin; Bronchiolitis - RSV ... Crowe JE. Respiratory syncytial virus. In: Kliegman RM, Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ...

  3. Respiratory Issues in OI

    Respiratory Issues in Osteogenesis Imperfecta \\ Introduction The respiratory system’s job is to bring oxygen into the body and remove carbon dioxide, the waste product of breathing. Because oxygen is the fuel ...

  4. Acute respiratory distress syndrome

    ... page: //medlineplus.gov/ency/article/000103.htm Acute respiratory distress syndrome To use the sharing features on this page, please enable JavaScript. Acute respiratory distress syndrome (ARDS) is a life-threatening lung ...

  5. LEADIR-PS: the path to a safe and economic SMR

    Hart, R.S. [Nothern Nuclear Industries Inc., Cambridge, Ontario (Canada)

    2014-07-01

    Northern Nuclear Industries Incorporated (N{sup 2} I{sup 2}) is developing a family of Small Modular Reactors (SMRs) called LEADIR-PS, an acronym for LEAD-cooled Integral Reactor-Passively Safe. LEADIR-PS plants under development, focused on process heat applications and the energy demands of Canada, are the LEADIR-PS100 with an output of 100 MWth and LEADIR-PS300 with an output of 300 MWth. A plant consisting of six LEADIR-PS300 reactor modules serving a common turbine-generator, called the LEADIR-PS Six-Pack, is focused on serving areas with higher energy demands. LEADIR-PS integrates the inherent safety features of the Modular High Temperature Gas Reactor and molten lead coolant in an integral pool type reactor configuration. Molten lead coolant, which boils at 1750 {sup o}C,avoids the cost of a reactor pressure vessel and high pressure/high temperature reactor coolant systems, and the safety concerns regarding pressure vessel and large capacity reactor coolant system piping rupture and precludes evaporation of the coolant. Molten lead does not chemically react with air, water, or graphite. The Gen IV+ LEADIR-PS plants are inherently/passively safe. There are no active systems required for safe shutdown and decay heat removal. Safety is assured without active or stored energy power supply, without a requirement to reposition valves or other devices and operator intervention or action. The unprecedented safety achieved by LEADIR-PS reactors avoids requirements for a large exclusion radius and demanding evacuation plan requirements. LEADIR-PS, with steam conditions of 370 {sup o}C and 12 MPa (more than twice that of water cooled reactors), can serve over 85% of the world's non-transportation process heat demands and is ideally suited to serving Combined Heat and Electricity demands and industrial parks. Energy utilization of over 95% is feasible in process heat and Combined Heat and Electricity applications. The simple robust design of LEADIR-PS plants in

  6. Assessment of Air Pollution Effects on the Respiratory System Based on Pulmonary Function Tests Performed During Spirometry Days.

    Dąbrowiecki, Piotr; Mucha, Dominika; Gayer, Anna; Adamkiewicz, Łukasz; Badyda, Artur J

    2015-01-01

    The Polish Spirometry Day is an initiative aimed at increasing awareness of the causes, symptoms, course, and effects that accompany respiratory diseases, especially asthma and chronic obstructive pulmonary disease (COPD). In 2013, the second edition of the Spirometry Day was held. It gathered 180 medical centers and other institution. The final analysis encompassed a total of 1187 persons from 26 different locations, including rural areas, and smaller and larger city agglomerations. Of this total, 755 persons (63.6 %) completed their spirometry tests for the first time in life. Each person fulfilled a questionnaire regarding the personal information, respiratory diseases, symptoms, lifestyle, and a place of residence. In the total group, 234 (19.7 %) cases of bronchial obstruction were diagnosed. A hundred and thirty four persons with obstruction, among those tested for the first time in life (17.8 %), were unaware of their disease. The lowest values of FEV1 and FEF(1)/FVC, corresponding to the highest percentage of persons with obstruction (27.9 %) were observed in small and medium cities (100,000-500,000 inhabitants). There were differences in the prevalence of obstruction depending on the distance of the place of residence from a busy traffic road. A significant decrease of both spirometric variables was observed among people living in cities above 100,000 inhabitants within a distance lower than 50 m from roads. In general, better spirometry results were observed among inhabitants living more than 150 m from main roads.

  7. Mycoplasma pneumoniae-associated encephalitis in childhood--nervous system disorder during or after a respiratory tract infection.

    Meyer Sauteur, P M; Streuli, J C; Iff, T; Goetschel, P

    2011-07-01

    Mycoplasma pneumoniae is an important aetiological agent of encephalitis in children, with encephalitis being the most frequent paediatric extrapulmonary manifestation of M. pneumoniae infections. Evidence of M. pneumoniae involvement in childhood encephalitis is difficult to obtain, because M. pneumoniae is seldom detected in the cerebrospinal fluid and the clinical picture shows gradual onset. Therefore, we present a small case-study as a paradigm of M. pneumoniae-associated encephalitis in childhood and illustrate the importance of this entity based on a review of previously published cases. We describe neurological signs and symptoms of 2 patients with M. pneumoniae-associated encephalitis in childhood. Respiratory symptoms with fever occurred in both children. They were seropositive for M. pneumoniae, but did not have the organism detected by PCR from cerebrospinal fluid. No long-term neurologic sequelae occurred. M. pneumoniae has to be considered as a responsible pathogen of encephalitis in children, even if respiratory symptoms do not occur. Due to the seldom detection of M. pneumoniae in cerebrospinal fluid, evidence of m. pneumoniae involvement in childhood encephalitis is difficult to obtain.Faced with a neurological disease with no organism detected in CNS in the majority of cases assumes that M. pneumoniae-associated encephalitis is most likely a paradigm for an autoimmune disease with uniform pathogenesis mediated by an immunologic response to an antecedent antigenic stimulus from M. pneumoniae. It is important to relate this organism to this relatively common and potentially devastating clinical syndrome. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Long-term effects of recurrent intermittent hypoxia and hyperoxia on respiratory system mechanics in neonatal mice.

    Dylag, Andrew M; Mayer, Catherine A; Raffay, Thomas M; Martin, Richard J; Jafri, Anjum; MacFarlane, Peter M

    2017-04-01

    Premature infants are at increased risk for wheezing disorders. Clinically, these neonates experience recurrent episodes of apnea and desaturation often treated by increasing the fraction of inspired oxygen (FIO 2 ). We developed a novel paradigm of neonatal intermittent hypoxia with subsequent hyperoxia overshoots (CIH O/E ) and hypothesized that CIH O/E elicits long-term changes on pulmonary mechanics in mice. Neonatal C57BL/6 mice received CIH O/E , which consisted of 10% O2 (1 min) followed by a transient exposure to 50% FIO 2 , on 10-min repeating cycles 24 h/d from birth to P7. Baseline respiratory mechanics, methacholine challenge, RT-PCR for pro and antioxidants, radial alveolar counts, and airway smooth muscle actin were assessed at P21 after 2-wk room air recovery. Control groups were mice exposed to normoxia, chronic intermittent hyperoxia (CIH E ), and chronic intermittent hypoxia (CIH O ). CIH O/E and CIH E increased airway resistance at higher doses of methacholine and decreased baseline compliance compared with normoxia mice. Lung mRNA for NOX2 was increased by CIH O/E . Radial alveolar counts and airway smooth muscle actin was not different between groups. Neonatal intermittent hypoxia/hyperoxia exposure results in long-term changes in respiratory mechanics. We speculate that recurrent desaturation with hyperoxia overshoot may increase oxidative stress and contribute to wheezing in former preterm infants.

  9. Development of patient-controlled respiratory gating system based on visual guidance for magnetic-resonance image-guided radiation therapy.

    Kim, Jung-In; Lee, Hanyoung; Wu, Hong-Gyun; Chie, Eui Kyu; Kang, Hyun-Cheol; Park, Jong Min

    2017-09-01

    The aim of this study is to develop a visual guidance patient-controlled (VG-PC) respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy (MR-IGRT) and to evaluate the performance of the developed system. The near-real-time cine planar MR image of a patient acquired during treatment was transmitted to a beam projector in the treatment room through an optical fiber cable. The beam projector projected the cine MR images inside the bore of the ViewRay system in order to be visible to a patient during treatment. With this visual information, patients voluntarily controlled their respiration to put the target volume into the gating boundary (gating window). The effect of the presence of the beam projector in the treatment room on the image quality of the MRI was investigated by evaluating the signal-to-noise ratio (SNR), uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity with the VG-PC gating system. To evaluate the performance of the developed system, we applied the VG-PC gating system to a total of seven patients; six patients received stereotactic ablative radiotherapy (SABR) and one patient received conventional fractionated radiation therapy. The projected cine MR images were visible even when the room light was on. No image data loss or additional time delay during delivery of image data were observed. Every indicator representing MRI quality, including SNR, uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity exhibited values higher than the tolerance levels of the manufacturer with the VG-PC gating system; therefore, the presence of the VG-PC gating system in the treatment room did not degrade the MR image quality. The average beam-off times due to respiratory gating with and without the VG-PC gating system were 830.3 ± 278.2 s and 1264.2 ± 302.1 s respectively (P = 0.005). Consequently, the total treatment times excluding

  10. What Is Respiratory Distress Syndrome?

    ... Home / Respiratory Distress Syndrome Respiratory Distress Syndrome Also known as What Is Respiratory ... This condition is called apnea (AP-ne-ah). Respiratory Distress Syndrome Complications Depending on the severity of ...

  11. Severe acute respiratory syndrome (SARS)

    SARS; Respiratory failure - SARS ... Complications may include: Respiratory failure Liver failure Heart failure ... 366. McIntosh K, Perlman S. Coronaviruses, including severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS). ...

  12. The Virome and Its Major Component, Anellovirus, a Convoluted System Molding Human Immune Defenses and Possibly Affecting the Development of Asthma and Respiratory Diseases in Childhood

    Giulia Freer

    2018-04-01

    Full Text Available The microbiome, a thriving and complex microbial community colonizing the human body, has a broad impact on human health. Colonization is a continuous process that starts very early in life and occurs thanks to shrewd strategies microbes have evolved to tackle a convoluted array of anatomical, physiological, and functional barriers of the human body. Cumulative evidence shows that viruses are part of the microbiome. This part, called virome, has a dynamic composition that reflects what we eat, how and where we live, what we do, our genetic background, and other unpredictable variables. Thus, the virome plays a chief role in shaping innate and adaptive host immune defenses. Imbalance of normal microbial flora is thought to trigger or exacerbate many acute and chronic disorders. A compelling example can be found in the respiratory apparatus, where early-life viral infections are major determinants for the development of allergic diseases, like asthma, and other non-transmissible diseases. In this review, we focus on the virome and, particularly, on Anelloviridae, a recently discovered virus family. Anelloviruses are major components of the virome, present in most, if not all, human beings, where they are acquired early in life and replicate persistently without causing apparent disease. We will discuss how modulation of innate and adaptive immune systems by Anelloviruses can influence the development of respiratory diseases in childhood and provide evidence for the use of Anelloviruses as useful and practical molecular markers to monitor inflammatory processes and immune system competence.

  13. Improvements in SMR Modular Construction through Supply Chain Optimization and Lessons Learned

    White III, Chelsea C. [Georgia Tech Research Corporation, Atlanta, GA (United States); Petrovic, Bojan [Georgia Tech Research Corporation, Atlanta, GA (United States)

    2017-03-30

    Affordable energy is a critical societal need. Capital construction cost is a significant portion of nuclear energy cost. By controlling and reducing cost, companies can build more competitive nuclear power plants and hence provide access to more affordable energy. Modular construction provides an opportunity to reduce the cost of construction, and as projects scale up in number, the cost of each unit can be further reduced. The objective of this project was to advance design and construction methods for manufacturing Small Modular Reactors (SMRs), and in particular to improve modular construction techniques and develop best practices for designing and operating supply chains that take advantage of these techniques. The overarching objectives were to accelerate the construction schedule and reduce its variability, reduce the cost of construction, reduce interest costs accrued during construction (IDC), and thus enhance the economic attractiveness of SMRs. Our fundamental measure of merit was total capital investment cost (TCIC). To achieve these objectives, this project developed a decision support system, EVAL, to support identifying, addressing, and resolving or ameliorating challenges and deficiencies in the current modular construction approach. The results of this effort were consistent with the facts that the cost of a construction activity is often smallest when accomplished in the factory, greatest when accomplished at the construction site, and at an intermediate level when accomplished at an assembly area close to the construction site. Further, EVAL can aid in providing insight into ways to reduce waste, improve quality, efficiency, and throughput and reflects the fact that the more done early in the construction process, i.e., in the factory, the more upfront funding is required and hence the more IDC will be accrued. The analysis has lead to a better understanding of circumstances under which modular construction performed mainly in the factory will

  14. Respiratory syncytial virus, pneumonia virus of mice, and influenza A virus differently affect respiratory allergy in mice

    Barends, M.; de Rond, L. G. H.; Dormans, J.; van Oosten, M.; Boelen, A.; Neijens, H. J.; Osterhaus, A. D. M. E.; Kimman, T. G.

    2004-01-01

    Respiratory viral infections in early childhood may interact with the immune system and modify allergen sensitization and/or allergic manifestations. In mice, respiratory syncytial virus (RSV) infection during allergic provocation aggravates the allergic T helper (Th) 2 immune response,

  15. Respiratory Depression Caused by Heroin Use

    Kadir Hakan Cansiz

    2012-04-01

    Full Text Available Summary Heroin is a semisynthetic narcotic analgesic and heroin abuse is common due to its pleasure-inducing effect. For the last 30 years heroin abuse has become an important worldwide public health problem. Heroin can be administered in many different ways as preferred. Heroin affects many systems including respiratory system, cardiovascular system and particulary the central nervous system. Overdose use of heroin intravenously can be fatal due to respiratory depression. In this letter, we wanted to engage attention to respiratory depression caused by heroin abuse and potential benefits of using naloxone. [TAF Prev Med Bull 2012; 11(2.000: 248-250

  16. Stereotactic body radiotherapy for stage I lung cancer and small lung metastasis: evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary results

    Ayakawa Shiho

    2009-05-01

    Full Text Available Abstract Background In stereotactic body radiotherapy (SBRT for lung tumors, reducing tumor movement is necessary. In this study, we evaluated changes in tumor movement and percutaneous oxygen saturation (SpO2 levels, and preliminary clinical results of SBRT using the BodyFIX immobilization system. Methods Between 2004 and 2006, 53 consecutive patients were treated for 55 lesions; 42 were stage I non-small cell lung cancer (NSCLC, 10 were metastatic lung cancers, and 3 were local recurrences of NSCLC. Tumor movement was measured with fluoroscopy under breath holding, free breathing on a couch, and free breathing in the BodyFIX system. SpO2 levels were measured with a finger pulseoximeter under each condition. The delivered dose was 44, 48 or 52 Gy, depending on tumor diameter, in 4 fractions over 10 or 11 days. Results By using the BodyFIX system, respiratory tumor movements were significantly reduced compared with the free-breathing condition in both craniocaudal and lateral directions, although the amplitude of reduction in the craniocaudal direction was 3 mm or more in only 27% of the patients. The average SpO2 did not decrease by using the system. At 3 years, the local control rate was 80% for all lesions. Overall survival was 76%, cause-specific survival was 92%, and local progression-free survival was 76% at 3 years in primary NSCLC patients. Grade 2 radiation pneumonitis developed in 7 patients. Conclusion Respiratory tumor movement was modestly suppressed by the BodyFIX system, while the SpO2 level did not decrease. It was considered a simple and effective method for SBRT of lung tumors. Preliminary results were encouraging.

  17. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial.

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N T; Schultz, Marcus J; Pelosi, Paolo; Kaczka, David W; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications when compared to low PEEP (0-2 cm H2O) approach without recruitment breaths. However, effects of intraoperative PEEP on lung compliance remain poorly understood. We hypothesized that higher PEEP leads to a dominance of intratidal overdistension, whereas lower PEEP results in intratidal recruitment/derecruitment (R/D). To test our hypothesis, we used the volume-dependent elastance index %E2, a respiratory parameter that allows for noninvasive and radiation-free assessment of dominant overdistension and intratidal R/D. We compared the incidence of intratidal R/D, linear expansion, and overdistension by means of %E2 in a subset of the PROVHILO cohort. In 36 patients from 2 participating centers of the PROVHILO trial, we calculated respiratory system elastance (E), resistance (R), and %E2, a surrogate parameter for intratidal overdistension (%E2 > 30%) and R/D (%E2 mechanical ventilation with protective tidal volumes in patients undergoing open abdominal surgery, lung recruitment followed by PEEP of 12 cm H2O decreased the incidence of intratidal R/D and did not worsen overdistension, when compared to PEEP ≤2 cm H2O.

  18. Respiratory neuroplasticity - Overview, significance and future directions.

    Fuller, David D; Mitchell, Gordon S

    2017-01-01

    Neuroplasticity is an important property of the neural system controlling breathing. However, our appreciation for its importance is still relatively new, and we have much to learn concerning different forms of plasticity, their underlying mechanisms, and their biological and clinical significance. In this brief review, we discuss several well-studied models of respiratory plasticity, including plasticity initiated by inactivity in the respiratory system, intermittent and sustained hypoxia, and traumatic injury to the spinal cord. Other aspects of respiratory plasticity are considered in other contributions to this special edition of Experimental Neurology on respiratory plasticity. Finally, we conclude with discussions concerning the biological and clinical significance of respiratory motor plasticity, and areas in need of future research effort. Copyright © 2016. Published by Elsevier Inc.

  19. Quality assurance program of a respiratory gating irradiation system based on external and internal fiducial markers; Programa de garantia de calidad de un sistema de irradiacion con control respiratorio basado en marcadores fiduciales externos e internos

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrilla, J.; Minambres Moro, A.

    2011-07-01

    Respiratory Gating involves the administration of radiation during treatment delivery within a particular portion of the patients breathing cycle, so the absorbed dose administration with respiratory control techniques requires specific quality control to ensure the correctness of the delivered dose. The establishment of a Quality Control Program (QC) is proposed for the Respiratory Gating based techniques in order to have a better understanding of how this system works and to know its associated dosimetric impact. The influence of the CT acquisition under respiratory motion conditions has been analyzed for the treatment isocenter localization, using internal and external fiducial markers with IGRT techniques that allow the correlation of the isocenter positioning with the phase of the respiratory cycle. Radiation delivery in the presence of intra fraction organ motion causes an averaging or blurring of the static dose distribution over the path of motion increasing the beam penumbra of the radiation field and reducing the therapeutic region when the irradiation is not breath controlled. The feasibility of intensity modulated treatments (IMRT) for both static and dynamic techniques, managed by respiratory control has been tested, demonstrating the possibility of synchronizing the movement of the leaves in the microfluorimeter collimator (mMLC) with the gated beam irradiation. (Author) 45 refs.

  20. Optimization methodology for large scale fin geometry on the steel containment of a Public Acceptable Simple SMR (PASS)

    Kim, Do Yun; NO, Hee Cheon; Kim, Ho Sik

    2015-01-01

    Highlights: • Optimization methodology for fin geometry on the steel containment is established. • Optimum spacing is 7 cm in PASS containment. • Optimum thickness is 0.9–1.8 cm when a fin height is 10–25 cm. • Optimal fin geometry is determined in given fin height by overall effectiveness correlation. • 13% of material volume and 43% of containment volume are reduced by using fins. - Abstracts: Heat removal capability through a steel containment is important in accident situations to preserve the integrity of a nuclear power plant which adopts a steel containment concept. A heat transfer rate will be enhanced by using fins on the external surface of the steel containment. The fins, however, cause to increase flow resistance and to deteriorate the heat transfer rate at the same time. Therefore, this study investigates an optimization methodology of large scale fin geometry for a vertical base where a natural convection flow regime is turbulent. Rectangular plate fins adopted in the steel containment of a Public Acceptable Simple SMR (PASS) is used as a reference. The heat transfer rate through the fins is obtained from CFD tools. In order to optimize fin geometry, an overall effectiveness concept is introduced as a fin performance parameter. The optimizing procedure is starting from finding optimum spacing. Then, optimum thickness is calculated and finally optimal fin geometry is suggested. Scale analysis is conducted to show the existence of an optimum spacing which turns out to be 7 cm in case of PASS. Optimum thickness is obtained by the overall effectiveness correlation, which is derived from a total heat transfer coefficient correlation. The total heat transfer coefficient correlation of a vertical fin array is suggested considering both of natural convection and radiation. However, the optimum thickness is changed as a fin height varies. Therefore, optimal fin geometry is obtained as a function of a fin height. With the assumption that the heat

  1. Genetic and functional characterization of a novel meta-pathway for degradation of naringenin in Herbaspirillum seropedicae SmR1.

    Maria Marin, Anelis; de la Torre, Jésus; Ricardo Marques Oliveira, Alfredo; Barison, Andersson; Satie Chubatsu, Leda; Adele Monteiro, Rose; de Oliveira Pedrosa, Fabio; Maltempi de Souza, Emanuel; Wassem, Roseli; Duque, Estrella; Ramos, Juan-Luis

    2016-12-01

    In this study, a random mutant library of Herbaspirillum seropedicae SmR1 was constructed by Tn5 insertion and a mutant incapable of utilizing naringenin as a carbon source was isolated. The Tn5 transposon was found to be inserted in the fdeE gene (Hsero_1007), which encodes a monooxygenase. Two other mutant strains in fdeC (Hsero_1005) and fdeG (Hsero_1009) genes coding for a dioxygenase and a putative cyclase, respectively, were obtained by site-directed mutagenesis and then characterized. Liquid Chromatography coupled to mass spectrometry (LC-MS)/MS analyses of culture supernatant from the fdeE mutant strain revealed that naringenin remained unaltered, suggesting that the FdeE protein is involved in the initial step of naringenin degradation. LC-MS/MS analyses of culture supernatants from the wild-type (SmR1) and FdeC deficient mutant suggested that in H. seropedicae SmR1 naringenin is first mono-oxygenated by the FdeE protein, to produce 5,7,8-trihydroxy-2-(4-hydroxyphenyl)-2,3-dihydro-4H-chromen-4-one, that is subsequently dioxygenated and cleaved at the A-ring by the FdeC dioxygenase, since the latter compound accumulated in the fdeC strain. After meta-cleavage of the A-ring, the subsequent metabolic steps generate oxaloacetic acid that is metabolized via the tricarboxylic acid cycle. This bacterium can also modify naringenin by attaching a glycosyl group to the B-ring or a methoxy group to the A-ring, leading to the generation of dead-end products. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  2. The polymorphism of CYP2E1 Rsa I/Pst I gene and susceptibility to respiratory system cancer: a systematic review and meta-analysis of 34 studies.

    Xu, Li; Yang, Mingyuan; Zhao, Tiejun; Jin, Hai; Xu, Zhiyun; Li, Ming; Chen, Hezhong

    2014-12-01

    The purpose of this articles is to determine whether the cytochrome P450 2E1 (CYP2E1) Rsa I/Pst I gene polymorphism is correlated with respiratory system cancers. Respiratory system cancers included lung cancer, laryngeal cancer, nasopharyngeal cancer, and cancers of other respiratory organs, which are the most common malignant tumors worldwide; the significant relationship between CYP2E1 Rsa I/Pst I gene polymorphism and some respiratory system cancer have been reported, but results of some other studies are controversial. The pooled odds ratio (OR) with 95% confidence interval (CI) was calculated to assess the association. PubMed, EMBASE, Cochrane Library Databases, China National Knowledge Infrastructure, and Wanfang Database (up to July 20, 2014) were searched for all case-control studies those mainly studied the relationship between CYP2E1 Rsa I/Pst I gene polymorphism and the susceptibility of respiratory system cancer. A total of 332 articles were collected, among which 34 studies that involved 7028 cases and 9822 controls fulfilled the inclusion criteria after being assessed by 2 reviewers. When stratified by cancer site, the C2/C2 polymorphism could increase the risk of nasopharyngeal cancer under the homozygote model (C2C2 vs C1C1: OR = 1.85, 95% CI = 1.20-2.85, P = 0.005) and recessive model (C2C2 vs C1C2/C1C1: OR = 1.89, 95% CI = 1.23-2.89, P = 0.003). Protection effect was found in lung cancer in heterozygote model (C1C2 vs C1C1: OR = 0.82, 95% CI = 0.74-0.91, P Rsa I/Pst I gene polymorphism may reduce the risk of respiratory system cancer. Furthermore, significant association was also found in Asian populations.

  3. Westinghouse Small Modular Reactor balance of plant and supporting systems design

    Memmott, M. J.; Stansbury, C.; Taylor, C. [Westinghouse Electric Company LLC, 600 Cranberry Woods Drive, Cranberry Twp. PA 16066 (United States)

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the second in a series of four papers which describe the design and functionality of the Westinghouse SMR. It focuses, in particular, upon the supporting systems and the balance of plant (BOP) designs of the Westinghouse SMR. Several Westinghouse SMR systems are classified as safety, and are critical to the safe operation of the Westinghouse SMR. These include the protection and monitoring system (PMS), the passive core cooling system (PXS), and the spent fuel cooling system (SFS) including pools, valves, and piping. The Westinghouse SMR safety related systems include the instrumentation and controls (I and C) as well as redundant and physically separated safety trains with batteries, electrical systems, and switch gears. Several other incorporated systems are non-safety related, but provide functions for plant operations including defense-in-depth functions. These include the chemical volume control system (CVS), heating, ventilation and cooling (HVAC) systems, component cooling water system (CCS), normal residual heat removal system (RNS) and service water system (SWS). The integrated performance of the safety-related and non-safety related systems ensures the safe and efficient operation of the Westinghouse SMR through various conditions and transients. The turbine island consists of the turbine, electric generator, feedwater and steam systems, moisture separation systems, and the condensers. The BOP is designed to minimize assembly time, shipping challenges, and on-site testing requirements for all structures, systems, and components. (authors)

  4. Westinghouse Small Modular Reactor balance of plant and supporting systems design

    Memmott, M. J.; Stansbury, C.; Taylor, C.

    2012-01-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the second in a series of four papers which describe the design and functionality of the Westinghouse SMR. It focuses, in particular, upon the supporting systems and the balance of plant (BOP) designs of the Westinghouse SMR. Several Westinghouse SMR systems are classified as safety, and are critical to the safe operation of the Westinghouse SMR. These include the protection and monitoring system (PMS), the passive core cooling system (PXS), and the spent fuel cooling system (SFS) including pools, valves, and piping. The Westinghouse SMR safety related systems include the instrumentation and controls (I and C) as well as redundant and physically separated safety trains with batteries, electrical systems, and switch gears. Several other incorporated systems are non-safety related, but provide functions for plant operations including defense-in-depth functions. These include the chemical volume control system (CVS), heating, ventilation and cooling (HVAC) systems, component cooling water system (CCS), normal residual heat removal system (RNS) and service water system (SWS). The integrated performance of the safety-related and non-safety related systems ensures the safe and efficient operation of the Westinghouse SMR through various conditions and transients. The turbine island consists of the turbine, electric generator, feedwater and steam systems, moisture separation systems, and the condensers. The BOP is designed to minimize assembly time, shipping challenges, and on-site testing requirements for all structures, systems, and components. (authors)

  5. Respiratory correlated cone beam CT

    Sonke, Jan-Jakob; Zijp, Lambert; Remeijer, Peter; Herk, Marcel van

    2005-01-01

    A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated procedure for CBCT and evaluated its performance. This respiratory correlated CBCT procedure consists of retrospective sorting in projection space, yielding subsets of projections that each corresponds to a certain breathing phase. Subsequently, these subsets are reconstructed into a four-dimensional (4D) CBCT dataset. The breathing signal, required for respiratory correlation, was directly extracted from the 2D projection data, removing the need for an additional respiratory monitor system. Due to the reduced number of projections per phase, the contrast-to-noise ratio in a 4D scan reduced by a factor 2.6-3.7 compared to a 3D scan based on all projections. Projection data of a spherical phantom moving with a 3 and 5 s period with and without simulated breathing irregularities were acquired and reconstructed into 3D and 4D CBCT datasets. The positional deviations of the phantoms center of gravity between 4D CBCT and fluoroscopy were small: 0.13±0.09 mm for the regular motion and 0.39±0.24 mm for the irregular motion. Motion artifacts, clearly present in the 3D CBCT datasets, were substantially reduced in the 4D datasets, even in the presence of breathing irregularities, such that the shape of the moving structures could be identified more accurately. Moreover, the 4D CBCT dataset provided information on the 3D trajectory of the moving structures, absent in the 3D data. Considerable breathing irregularities, however, substantially reduces the image quality. Data presented for three different lung cancer patients were in line with the results obtained from the phantom study. In

  6. [Predictive values of different critical scoring systems for mortality in patients with severe acute respiratory failure supported by extracorporeal membrane oxygenation].

    Wang, R; Sun, B; Li, X Y; He, H Y; Tang, X; Zhan, Q Y; Tong, Z H

    2016-09-01

    To investigate the predictive values of different critical scoring systems for mortality in patients with severe acute respiratory failure (ARF) supported by venovenous extracorporeal membrane oxygenation (VV-ECMO). Forty-two patients with severe ARF supported by VV-ECMO were enrolled from November 2009 to July 2015.There were 25 males and 17 females. The mean age was (44±18) years (rang 18-69 years). Acute Physiology and Chronic Health Evaluation (APACHE) Ⅱ, Ⅲ, Ⅳ, Simplified Acute Physiology Score Ⅱ (SAPS) Ⅱ, Sequential Organ Failure Assessment (SOFA), ECMO net, PRedicting dEath for SEvere ARDS on VVECMO (PRESERVE), and Respiratory ECMO Survival Prediction (RESP) scores were collected within 6 hours before VV-ECMO support. The patients were divided into the survivors group (n=17) and the nonsurvivors group (n=25) by survival at 180 d after receiving VV-ECMO. The patient clinical characteristics and aforementioned scoring systems were compared between groups. Scoring systems for predicting prognosis were assessed using the area under the receiver-operating characteristic (ROC) curve. The Kaplan-Meier method was used to draw the surviving curve, and the survival of the patients was analyzed by the Log-rank test. The risk factors were assessed for prognosis by multiple logistic regression analysis. (1) Positive end expiratory pressure (PEEP) 6 hours prior to VV-ECMO support in the survivors group [(9.7±5.0)cmH2O, (1 cmH2O=0.098 kPa)] was lower than that in the nonsurvivors group [(13.2±5.4)cmH2O, t=-2.134, P=0.039]. VV-ECMO combination with continuous renal replacement therapy(CRRT) in the nonsurvivors group (32%) was used more than in the survivors group (6%, χ(2)=4.100, P=0.043). Duration of VV-ECMO support in the nonsurvivors group [(15±13) d] was longer than that in the survivors group [(12±11)d, t=-2.123, P=0.041]. APACHE Ⅱ, APACHE Ⅲ, APACHE Ⅳ, ECMO net, PRESERVE, and RESP scores in the survivors group were superior to the nonsurvivors

  7. Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy

    Kang, Dong Im; Jung, Sang Hoon; Kim, Chul Jong; Park, Hee Chul; Choi, Byung Ki

    2015-01-01

    External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40%-60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (0.71 sec), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). This study is

  8. Respiratory muscle training for multiple sclerosis

    Rietberg, Marc B.; Veerbeek, Janne M.; Gosselink, Rik; Kwakkel, Gert; van Wegen, Erwin E.H.

    2017-01-01

    Background: Multiple sclerosis (MS) is a chronic disease of the central nervous system, affecting approximately 2.5 million people worldwide. People with MS may experience limitations in muscular strength and endurance - including the respiratory muscles, affecting functional performance and

  9. Effects of air pollution on respiratory health

    Hasan Bayram

    2015-01-01

    In conclusion, air pollutants can induce respiratory mortality and morbidity by leading to airway and lung inflammation and impairing the airway defence system against noxious agents and microorganisms such as mycobacteria TB.

  10. Chronic respiratory disfunction due to diffuse alveolar hemorrhage in patients with systemic lupus erythematosus and primary vasculitis.

    Pérez Aceves, Eva; Pérez Cristóbal, Mario; Espinola Reyna, Gerardo A; Ariza Andraca, Raul; Xibille Fridmann, Daniel; Barile Fabris, Leonor A

    2013-01-01

    Pulmonary hemorrhage (PH) occurs in 2-5% of SLE patients, and is associated with a high mortality rate (79-90%). Diagnostic criteria for this complication include: 1) Pulmonary infiltrates, with at least ¾ of lung tissue involved in a chest x ray, 2) Acute respiratory failure, 3) A decrease of 3g/dL or more in hemoglobin levels. PH might lead to organized pneumonia, collagen deposition, and pulmonary fibrosis which in time might cause changes in pulmonary function tests with either restrictive or obstructive patterns. To evaluate the existence of abnormalities in pulmonary function tests after a PH episode. We included patients with SLE and primary vasculitis that developed PH. During the acute episode, we measured SLEDAI in SLE patients, five factor score in microscopic polyangiitis (MPA) and Birmingham Vasculitis Activity Store (BVAS) in granulomatosis with polyangiitis (GPA) (Wegener). We determined the number of PH events, treatment, and ventilator assistance requirements and correlated its association with abnormal pulmonary function tests. We included 10 patients, 7 with SLE, 2 with MPA and 1 with GPA (Wegener). The mean activity measures were: SLEDAI 20.4 ± 7.5, FFS 2, and BVAS 36. Treatment consisted in methylprednisolone (MPD) in 3 patients, MPD plus cyclophosphamide (CY) in 6 patients, and MPD, CY, IV immunoglobulin, and plasmapheresis in one patient. Five patients required ventilatory support. We found abnormalities in pulmonary function tests in 8 patients, three had an obstructive pattern and five a restrictive pattern; 2 patients did not show any change. We did not find a significant association with any of the studied variables. PH might cause abnormalities in pulmonary function tests and prolonged immunosuppressive treatment could be required. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  11. Adhesion properties of styrene-butadiene rubber (SBR/Standard Malaysian Rubber (SMR L-based adhesives in the presence of phenol formaldehyde resin

    2007-10-01

    Full Text Available The adhesion properties, i. e. viscosity, tack and peel strength of styrene-butadiene rubber (SBR/Standard Malaysian Rubber (SMR L-based pressure-sensitive adhesive was studied using phenol formaldehyde resin as the tackifying resin. Toluene was used as the solvent throughout the experiment. SBR composition in SBR/SMR L blend used was 0, 20, 40, 60, 80, 100%. Three different resin loadings, i. e. 40, 80 and 120 parts per hundred parts of rubber (phr were used in the adhesive formulation. The viscosity of adhesive was determined by a HAAKE Rotary Viscometer whereas loop tack and peel strength of paper/polyethylene terephthalate (PET film were measured using a Lloyd Adhesion Tester operating at 30 cm/min. Results indicate that the viscosity of adhesive decreases with increasing % SBR whereas loop tack passes through a maximum value at 20% SBR for all resin loadings. Except for the control sample (without resin, the peel strength shows a maximum value at 60% SBR for the three modes of peel tests. For a fixed % SBR, adhesive sample containing 40 phr phenol formaldehyde resin always exhibits the highest loop tack and peel strength, an observation which is associated to the optimum wettability of adhesive on the substrate.

  12. Cleavage of a Neuroinvasive Human Respiratory Virus Spike Glycoprotein by Proprotein Convertases Modulates Neurovirulence and Virus Spread within the Central Nervous System.

    Alain Le Coupanec

    Full Text Available Human coronaviruses (HCoV are respiratory pathogens that may be associated with the development of neurological diseases, in view of their neuroinvasive and neurotropic properties. The viral spike (S glycoprotein is a major virulence factor for several coronavirus species, including the OC43 strain of HCoV (HCoV-OC43. In an attempt to study the role of this protein in virus spread within the central nervous system (CNS and neurovirulence, as well as to identify amino acid residues important for such functions, we compared the sequence of the S gene found in the laboratory reference strain HCoV-OC43 ATCC VR-759 to S sequences of viruses detected in clinical isolates from the human respiratory tract. We identified one predominant mutation at amino acid 758 (from RRSR↓ G758 to RRSR↓R758, which introduces a putative furin-like cleavage (↓ site. Using a molecular cDNA infectious clone to generate a corresponding recombinant virus, we show for the first time that such point mutation in the HCoV-OC43 S glycoprotein creates a functional cleavage site between the S1 and S2 portions of the S protein. While the corresponding recombinant virus retained its neuroinvasive properties, this mutation led to decreased neurovirulence while potentially modifying the mode of virus spread, likely leading to a limited dissemination within the CNS. Taken together, these results are consistent with the adaptation of HCoV-OC43 to the CNS environment, resulting from the selection of quasi-species harboring mutations that lead to amino acid changes in viral genes, like the S gene in HCoV-OC43, which may contribute to a more efficient establishment of a less pathogenic but persistent CNS infection. This adaptative mechanism could potentially be associated with human encephalitis or other neurological degenerative pathologies.

  13. Sulfur mustard and respiratory diseases.

    Tang, Feng Ru; Loke, Weng Keong

    2012-09-01

    Victims exposed to sulfur mustard (HD) in World War I and Iran-Iraq war, and those suffered occupational or accidental exposure have endured discomfort in the respiratory system at early stages after exposure, and marked general physical deterioration at late stages due to pulmonary fibrosis, bronchiolitis obliterans or lung cancer. At molecule levels, significant changes of cytokines and chemokines in bronchoalveolar lavage and serum, and of selectins (in particular sE-selectin) and soluble Fas ligand in the serum have been reported in recent studies of patients exposed to HD in Iran-Iraq war, suggesting that these molecules may be associated with the pathophysiological development of pulmonary diseases. Experimental studies in rodents have revealed that reactive oxygen and nitrogen species, their product peroxynitrite (ONOO(-)), nitric oxide synthase, glutathione, poly (adenosine diphosphate-ribose) polymerase, activating protein-1 signaling pathway are promising drug targets for preventing HD-induced toxicity, whereas N-acetyl cysteine, tocopherols, melatonin, aprotinin and many other molecules have been proved to be effective in prevention of HD-induced damage to the respiratory system in different animal models. In this paper, we will systemically review clinical and pathophysiological changes of respiratory system in victims exposed to HD in the last century, update clinicians and researchers on the mechanism of HD-induced acute and chronic lung damages, and on the relevant drug targets for future development of antidotes for HD. Further research directions will also be proposed.

  14. Diagram-based Analysis of Causal Systems (DACS): elucidating inter-relationships between determinants of acute lower respiratory infections among children in sub-Saharan Africa.

    Rehfuess, Eva A; Best, Nicky; Briggs, David J; Joffe, Mike

    2013-12-06

    Effective interventions require evidence on how individual causal pathways jointly determine disease. Based on the concept of systems epidemiology, this paper develops Diagram-based Analysis of Causal Systems (DACS) as an approach to analyze complex systems, and applies it by examining the contributions of proximal and distal determinants of childhood acute lower respiratory infections (ALRI) in sub-Saharan Africa. Diagram-based Analysis of Causal Systems combines the use of causal diagrams with multiple routinely available data sources, using a variety of statistical techniques. In a step-by-step process, the causal diagram evolves from conceptual based on a priori knowledge and assumptions, through operational informed by data availability which then undergoes empirical testing, to integrated which synthesizes information from multiple datasets. In our application, we apply different regression techniques to Demographic and Health Survey (DHS) datasets for Benin, Ethiopia, Kenya and Namibia and a pooled World Health Survey (WHS) dataset for sixteen African countries. Explicit strategies are employed to make decisions transparent about the inclusion/omission of arrows, the sign and strength of the relationships and homogeneity/heterogeneity across settings.Findings about the current state of evidence on the complex web of socio-economic, environmental, behavioral and healthcare factors influencing childhood ALRI, based on DHS and WHS data, are summarized in an integrated causal diagram. Notably, solid fuel use is structured by socio-economic factors and increases the risk of childhood ALRI mortality. Diagram-based Analysis of Causal Systems is a means of organizing the current state of knowledge about a specific area of research, and a framework for integrating statistical analyses across a whole system. This partly a priori approach is explicit about causal assumptions guiding the analysis and about researcher judgment, and wrong assumptions can be reversed

  15. Evaluation of alternative strategies to MERV 16-based air filtration systems for reduction of the risk of airborne spread of porcine reproductive and respiratory syndrome virus.

    Dee, Scott; Pitkin, Andrea; Deen, John

    2009-07-02

    Porcine reproductive and respiratory syndrome (PRRS) is a re-emerging disease of pigs and a growing threat to the global swine industry. For sustainable disease control it is critical to prevent the airborne spread of the etiologic agent, PRRS virus, between pig populations. The application of MERV 16-based air filtration systems to swine facilities in an effort to reduce this risk has been proposed; however, due to the cost and air flow restrictions of such systems the need for alternative strategies has arisen. Therefore, the objective of this study was to evaluate 3 groups of alternative biosecurity strategies for reducing the risk of the airborne spread of PRRSV. Strategies evaluated included mechanical filters, antimicrobial filters and a disinfectant-EVAP (evaporative cooling) system. Results from this study indicate that while alternatives to MERV 16-based biosecurity protocols for protecting farms from the airborne spread of PRRSV are available, further information on their efficacy in the field is needed before conclusions can be drawn.

  16. Respiratory physiology during early life.

    Stocks, J

    1999-08-01

    Despite the rapid adaptation to extrauterine life, the respiratory system of an infant is not simply a miniaturized version of that of an adult, since the rapid somatic growth that occurs during the first year of life is accompanied by major developmental changes in respiratory physiology. The highly compliant chest wall of the infant results in relatively low transpulmonary pressures at end expiration with increased tendency of the small peripheral airways to close during tidal breathing. This not only impairs gas exchange and ventilation-perfusion balance, particularly in dependent parts of the lung, but, together with the small absolute size of the airways, renders the infant and young child particularly susceptible to airway obstruction. Premature airways are highly compliant structures compared with those of mature newborns or adults. This increased compliance can cause airway collapse, resulting in increased airways resistance, flow limitation, poor gas exchange and increased work of breathing. Although there is clear evidence that airway reactivity is present from birth, its role in wheezing lower respiratory tract illnesses in young infants may be overshadowed by pre-existing abnormalities of airway geometry and lung mechanics, or by pathological changes such as airway oedema and mucus hypersecretion. Attempts to assess age-related changes in airway reactivity or response to aerosol therapy in the very young is confounded by changes in breathing patterns and the fact that infants are preferential nose breathers. There is increasing evidence that pre-existing abnormalities of respiratory function, associated with adverse events during foetal life (including maternal smoking during pregnancy), and familial predisposition to wheezing are important determinants of wheezing illnesses during the first years of life. This emphasizes the need to identify and minimize any factors that threaten the normal development of the lung during this critical period if

  17. Respiratory manifestations in endocrine diseases

    LENCU, CODRU?A; ALEXESCU, TEODORA; PETRULEA, MIRELA; LENCU, MONICA

    2016-01-01

    The control mechanisms of respiration as a vital function are complex: voluntary ? cortical, and involuntary ? metabolic, neural, emotional and endocrine. Hormones and hypothalamic neuropeptides (that act as neurotrasmitters and neuromodulators in the central nervous system) play a role in the regulation of respiration and in bronchopulmonary morphology. This article presents respiratory manifestations in adult endocrine diseases that evolve with hormone deficit or hypersecretion. In hyperthy...

  18. Synchrony - Cyberknife Respiratory Compensation Technology

    Ozhasoglu, Cihat; Saw, Cheng B.; Chen Hungcheng; Burton, Steven; Komanduri, Krishna; Yue, Ning J.; Huq, Saiful M.; Heron, Dwight E.

    2008-01-01

    Studies of organs in the thorax and abdomen have shown that these organs can move as much as 40 mm due to respiratory motion. Without compensation for this motion during the course of external beam radiation therapy, the dose coverage to target may be compromised. On the other hand, if compensation of this motion is by expansion of the margin around the target, a significant volume of normal tissue may be unnecessarily irradiated. In hypofractionated regimens, the issue of respiratory compensation becomes an important factor and is critical in single-fraction extracranial radiosurgery applications. CyberKnife is an image-guided radiosurgery system that consists of a 6-MV LINAC mounted to a robotic arm coupled through a control loop to a digital diagnostic x-ray imaging system. The robotic arm can point the beam anywhere in space with 6 degrees of freedom, without being constrained to a conventional isocenter. The CyberKnife has been recently upgraded with a real-time respiratory tracking and compensation system called Synchrony. Using external markers in conjunction with diagnostic x-ray images, Synchrony helps guide the robotic arm to move the radiation beam in real time such that the beam always remains aligned with the target. With the aid of Synchrony, the tumor motion can be tracked in three-dimensional space, and the motion-induced dosimetric change to target can be minimized with a limited margin. The working principles, advantages, limitations, and our clinical experience with this new technology will be discussed

  19. Respiratory medicine of reptiles.

    Schumacher, Juergen

    2011-05-01

    Noninfectious and infectious causes have been implicated in the development of respiratory tract disease in reptiles. Treatment modalities in reptiles have to account for species differences in response to therapeutic agents as well as interpretation of diagnostic findings. Data on effective drugs and dosages for the treatment of respiratory diseases are often lacking in reptiles. Recently, advances have been made on the application of advanced imaging modalities, especially computed tomography for the diagnosis and treatment monitoring of reptiles. This article describes common infectious and noninfectious causes of respiratory disease in reptiles, including diagnostic and therapeutic regimen. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Obesity and common respiratory diseases in children.

    Xanthopoulos, Melissa; Tapia, Ignacio E

    2017-06-01

    Obesity has become an important public health problem worldwide that disproportionally affects the underserved. Obesity has been associated with many diseases and unfortunately has not spared the respiratory system. Specifically, the prevalence of common respiratory problems, such as asthma and obstructive sleep apnoea, is higher in obese children. Further, the treatment outcomes of these frequent conditions is also worse in obese children compared to lean controls. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. [Immunomodulators in Therapy of Respiratory Infections].

    Isakov, V A; Isakov, D V

    2014-01-01

    Viral infections provoke dysbalance in the interferon system and inhibition of the cellular and phagocytic responses of the host. Long-term persistence of pathogenic viruses and bacteria induce atopy and could aggravate chronic respiratory diseases. The up-to-date classification of immunomodulators is described. High efficacy of interferon inductors, such as cycloferon and some others as auxiliary means in therapy or prophylaxis (immunorehabilitation) of viral respiratory infections in adults and children was shown.

  2. Supervisory Control System Architecture for Advanced Small Modular Reactors

    Cetiner, Sacit M [ORNL; Cole, Daniel L [University of Pittsburgh; Fugate, David L [ORNL; Kisner, Roger A [ORNL; Melin, Alexander M [ORNL; Muhlheim, Michael David [ORNL; Rao, Nageswara S [ORNL; Wood, Richard Thomas [ORNL

    2013-08-01

    This technical report was generated as a product of the Supervisory Control for Multi-Modular SMR Plants project within the Instrumentation, Control and Human-Machine Interface technology area under the Advanced Small Modular Reactor (SMR) Research and Development Program of the U.S. Department of Energy. The report documents the definition of strategies, functional elements, and the structural architecture of a supervisory control system for multi-modular advanced SMR (AdvSMR) plants. This research activity advances the state-of-the art by incorporating decision making into the supervisory control system architectural layers through the introduction of a tiered-plant system approach. The report provides a brief history of hierarchical functional architectures and the current state-of-the-art, describes a reference AdvSMR to show the dependencies between systems, presents a hierarchical structure for supervisory control, indicates the importance of understanding trip setpoints, applies a new theoretic approach for comparing architectures, identifies cyber security controls that should be addressed early in system design, and describes ongoing work to develop system requirements and hardware/software configurations.

  3. Vitamin D and respiratory disorder

    Mahnaz Hushmand

    2015-09-01

    Full Text Available The active form of vitamin D is synthesized in some body organs following sun exposure and dietary intake. Vitamin D exhibits its major and critical effects not only through regulation of calcium and phosphate metabolism but also by influencing on respiratory and immune system. Serum concentrations of 25-hydroxyvitamin D below the optimum limit lead to vitamin D insufficiency or maybe deficiency. These inappropriate concentrations of vitamin D lead to different types of pulmonary diseases such as viral and bacterial respiratory infection, asthma, chronic obstructive pulmonary disease, and cancer. In this review we described the association between vitamin D deficiency and severe therapy resistant asthma. We also reviewed the underlying molecular mechanism of vitamin D deficiency in children with severe- therapy resistant asthma. Based on current information, future clinical trial are needed to study the role of vitamin D supplementation on different groups of patients with severe asthma including infants, children of school age, and ethnic minorities.

  4. Respiratory Syncytial Virus (RSV)

    2013-02-04

    Respiratory Syncytial Virus, or RSV, causes cold-like symptoms but can be serious for infants and older adults. In this podcast, CDC’s Dr. Eileen Schneider discusses this common virus and offers tips to prevent its spread.  Created: 2/4/2013 by National Center for Immunization and Respiratory Diseases (NCIRD), Division of Viral Diseases (DVD).   Date Released: 2/13/2013.

  5. Acute respiratory distress syndrome

    Confalonieri, Marco; Salton, Francesco; Fabiano, Francesco

    2017-01-01

    Since its first description, the acute respiratory distress syndrome (ARDS) has been acknowledged to be a major clinical problem in respiratory medicine. From July 2015 to July 2016 almost 300 indexed articles were published on ARDS. This review summarises only eight of them as an arbitrary overview of clinical relevance: definition and epidemiology, risk factors, prevention and treatment. A strict application of definition criteria is crucial, but the diverse resource-setting scenarios foste...

  6. Respiratory Syncytial Virus Vaccines

    Dudas, Robert A.; Karron, Ruth A.

    1998-01-01

    Respiratory syncytial virus (RSV) is the most important cause of viral lower respiratory tract illness (LRI) in infants and children worldwide and causes significant LRI in the elderly and in immunocompromised patients. The goal of RSV vaccination is to prevent serious RSV-associated LRI. There are several obstacles to the development of successful RSV vaccines, including the need to immunize very young infants, who may respond inadequately to vaccination; the existence of two antigenically d...

  7. Macrophage-related serum biomarkers soluble CD163 (sCD163) and soluble mannose receptor (sMR) to differentiate mild liver fibrosis from cirrhosis in patients with chronic hepatitis C

    Andersen, E S; Rødgaard-Hansen, S; Moessner, B

    2014-01-01

    Macrophages regulate the fibrotic process in chronic liver disease. The aim of the present pilot study was to evaluate two new macrophage-specific serum biomarkers [soluble CD163 (sCD163) and soluble mannose receptor (sMR, sCD206)] as potential fibrosis markers in patients chronically infected wi...

  8. Managing respiratory problems in athletes.

    Hull, James H; Ansley, Les; Robson-Ansley, Paula; Parsons, Jonathan P

    2012-08-01

    Respiratory problems are common in athletes of all abilities and can significantly impact upon their health and performance. In this article, we provide an overview of respiratory physiology in athletes. We also discuss the assessment and management of common clinical respiratory conditions as they pertain to athletes, including airways disease, respiratory tract infection and pneumothorax. We focus on providing a pragmatic approach and highlight important caveats for the physician treating respiratory conditions in this highly specific population.

  9. Neurodegeneration in drop-dead mutant drosophila melanogaster is associated with the respiratory system but not with Hypoxia.

    Christine Lynn Sansone

    Full Text Available Mutations in the gene drop-dead (drd cause diverse phenotypes in adult Drosophila melanogaster including early lethality, neurodegeneration, tracheal defects, gut dysfunction, reduced body mass, and female sterility. Despite the identification of the drd gene itself, the causes of early lethality and neurodegeneration in the mutant flies remain unknown. To determine the pattern of drd expression associated with the neurodegenerative phenotype, knockdown of drd with various Gal4 drivers was performed. Early adult lethality and neurodegeneration were observed upon knockdown of drd in the tracheal system with two independent insertions of the breathless-Gal4 driver and upon knockdown in the tracheal system and elsewhere with the DJ717-Gal4 driver. Surprisingly, rescue of drd expression exclusively in the tracheae in otherwise mutant flies rescued the neurodegenerative phenotype but not adult lethality. Gut dysfunction, as measured by defecation rate, was not rescued in these flies, and gut function appeared normal upon tracheal-specific knockdown of drd. Finally, the hypothesis that tracheal dysfunction in drd mutants results in hypoxia was tested. Hypoxia-sensitive reporter transgenes (LDH-Gal4 and LDH-LacZ were placed on a drd mutant background, but enhanced expression of these reporters was not observed. In addition, manipulation of drd expression in the tracheae did not affect expression of the hypoxia-induced genes LDH, tango, and similar. Overall, these results indicate that there are at least two causes of adult lethality in drd mutants, that gut dysfunction and neurodegeneration are independent phenotypes, and that neurodegeneration is associated with tracheal expression of drd but not with hypoxia.

  10. A study of the x-ray image quality improvement in the examination of the respiratory system based on the new image processing technique

    Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio

    2014-03-01

    Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.

  11. Scaling laws for oxygen transport across the space-filling system of respiratory membranes in the human lung

    Hou, Chen

    Space-filling fractal surfaces play a fundamental role in how organisms function at various levels and in how structure determines function at different levels. In this thesis, we develop a quantitative theory of oxygen transport to and across the surface of the highly branched, space-filling system of alveoli, the fundamental gas exchange unit (acinar airways), in the human lung. Oxygen transport in the acinar airways is by diffusion, and we treat the two steps---diffusion through the branched airways, and transfer across the alveolar membranes---as a stationary diffusion-reaction problem, taking into account that there may be steep concentration gradients between the entrance and remote alveoli (screening). We develop a renormalization treatment of this screening effect and derive an analytic formula for the oxygen current across the cumulative alveolar membrane surface, modeled as a fractal, space-filling surface. The formula predicts the current from a minimum of morphological data of the acinus and appropriate values of the transport parameters, through a number of power laws (scaling laws). We find that the lung at rest operates near the borderline between partial screening and no screening; that it switches to no screening under exercise; and that the computed currents agree with measured values within experimental uncertainties. From an analysis of the computed current as a function of membrane permeability, we find that the space-filling structure of the gas exchanger is simultaneously optimal with respect to five criteria. The exchanger (i) generates a maximum oxygen current at minimum permeability; (ii) 'wastes' a minimum of surface area; (iii) maintains a minimum residence time of oxygen in the acinar airways; (iv) has a maximum fault tolerance to loss of permeability; and (v) generates a maximum current increase when switching from rest to exercise.

  12. Respiratory manifestations of hypothyroidism

    Sorensen, Jesper Roed; Winther, Kristian Hillert; Bonnema, Steen Joop

    2016-01-01

    BACKGROUND: Hypothyroidism has been associated with increased pulmonary morbidity and overall mortality. We conducted a systematic review to identify the prevalence and underlying mechanisms of respiratory problems among patients with thyroid insufficiency. METHODS: PubMed and EMBASE databases were...... searched for relevant literature from January 1950 through January 2015 with study eligibility criteria: English-language publications; Adult subclinical or overt hypothyroid patients; Intervention, observational or retrospective studies; and respiratory manifestations. We followed the PRISMA statement...... and used the Cochrane's risk of bias tool. RESULTS: A total of 1699 papers were screened by two independent authors for relevant titles. Of 109 relevant abstracts, 28 papers underwent full text analyses, of which 22 were included in the review. We identified possible mechanisms explaining respiratory...

  13. Evaluation of the Effectiveness of the Stereotactic Body Frame in Reducing Respiratory Intrafractional Organ Motion Using the Real-Time Tumor-Tracking Radiotherapy System

    Bengua, Gerard; Ishikawa, Masayori; Sutherland, Kenneth; Horita, Kenji; Yamazaki, Rie; Fujita, Katsuhisa; Onimaru, Rikiya; Katoh, Noriwo; Inoue, Tetsuya; Onodera, Shunsuke; Shirato, Hiroki

    2010-01-01

    Purpose: To evaluate the effectiveness of the stereotactic body frame (SBF), with or without a diaphragm press or a breathing cycle monitoring device (Abches), in controlling the range of lung tumor motion, by tracking the real-time position of fiducial markers. Methods and Materials: The trajectories of gold markers in the lung were tracked with the real-time tumor-tracking radiotherapy system. The SBF was used for patient immobilization and the diaphragm press and Abches were used to actively control breathing and for self-controlled respiration, respectively. Tracking was performed in five setups, with and without immobilization and respiration control. The results were evaluated using the effective range, which was defined as the range that includes 95% of all the recorded marker positions in each setup. Results: The SBF, with or without a diaphragm press or Abches, did not yield effective ranges of marker motion which were significantly different from setups that did not use these materials. The differences in the effective marker ranges in the upper lobes for all the patient setups were less than 1mm. Larger effective ranges were obtained for the markers in the middle or lower lobes. Conclusion: The effectiveness of controlling respiratory-induced organ motion by using the SBF+diaphragm press or SBF + Abches patient setups were highly dependent on the individual patient reaction to the use of these materials and the location of the markers. They may be considered for lung tumors in the lower lobes, but are not necessary for tumors in the upper lobes.

  14. Effect of body position on respiratory system volumes in anesthetized red-tailed hawks (Buteo jamaicensis) as measured via computed tomography.

    Malka, Shachar; Hawkins, Michelle G; Jones, James H; Pascoe, Peter J; Kass, Philip H; Wisner, Erik R

    2009-09-01

    To determine the effects of body position on lung and air-sac volumes in anesthetized and spontaneously breathing red-tailed hawks (Buteo jamaicensis). 6 adult red-tailed hawks (sex unknown). A crossover study design was used for quantitative estimation of lung and air-sac volumes in anesthetized hawks in 3 body positions: dorsal, right lateral, and sternal recumbency. Lung volume, lung density, and air-sac volume were calculated from helical computed tomographic (CT) images by use of software designed for volumetric analysis of CT data. Effects of body position were compared by use of repeated-measures ANOVA and a paired Student t test. Results for all pairs of body positions were significantly different from each other. Mean +/- SD lung density was lowest when hawks were in sternal recumbency (-677 +/- 28 CT units), followed by right lateral (-647 +/- 23 CT units) and dorsal (-630 +/- 19 CT units) recumbency. Mean lung volume was largest in sternal recumbency (28.6 +/- 1.5 mL), followed by right lateral (27.6 +/- 1.7 mL) and dorsal (27.0 +/- 1.5 mL) recumbency. Mean partial air-sac volume was largest in sternal recumbency (27.0 +/- 19.3 mL), followed by right lateral (21.9 +/- 16.1 mL) and dorsal (19.3 +/- 16.9 mL) recumbency. In anesthetized red-tailed hawks, positioning in sternal recumbency resulted in the greatest lung and air-sac volumes and lowest lung density, compared with positioning in right lateral and dorsal recumbency. Additional studies are necessary to determine the physiologic effects of body position on the avian respiratory system.

  15. Influence of eNOS gene 4a/bVNTR polymorphism on development of endothelial dysfunction and respiratory system disorders in children - residents of radioactively contaminated areas

    Stepanova, Je.Yi.; Kolpakov, Yi.Je.; Zigalo, V.M.; And Others

    2015-01-01

    Total of 184 children were examined to determine the possible associative links between eNOS gene intron 4m polymorphism and indices characterizing the functional state of the endothelium and the bronchopulmonary system. Of them the main group of children consisted of 135 childrenresidents of radioactively contaminated areas, the control group - of 49 healthy children who lived in ''clean'' regions by the radioactive con tamination and were not belonging to victims of the Chernobyl accident contingents. The molecular genetic study determining the eNOS gene intron 4 polymorphism was performed. Children of the main group did not differ from that of control and literature data by the frequency of geno types 4a/b and eNOS gene allele polymorphism. An increase in the duration of circulation restoration up to the ini tial level after occlusion test was noted in children of the main group with genotype 4a/4b comparing to children with genotype 4b/4b ; a decrease in the nitrite content was observed in blood serum. The integral indices of elastic ity and tensility of the lung tissue, respiratory permeability were decreased; the signs of bronchospasm were record ed 1.5 times more often. These adverse effects were associated with the presence of genotype allele 4a , the signs of endothelial dysfunction and the level of the incorporated 137 Cs. More pronounced changes in vascular endothelial reaction to occlusion and the significant decrease of serum nitrite level in allele 4a carriers, especially in children who live in adverse ecological conditions, give the right to include them into the risk group for the development of endothelial dysfunction, and to conside pulmonary dysfunction as one of its manifestations

  16. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance

    Korreman, S.S.; Boyer, A.L.; Juhler-Nøttrup, Trine

    2008-01-01

    PURPOSE/OBJECTIVE: In radiotherapy of targets moving with respiration, beam gating is offered as a means of reducing the target motion. The purpose of this study is to evaluate the safe magnitude of margin reduction for respiratory gated beam delivery. MATERIALS/METHODS: The study is based on data...... for 17 lung cancer patients in separate protocols at Rigshospitalet and Stanford Cancer Center. Respiratory curves for external optical markers and implanted fiducials were collected using equipment based on the RPM system (Varian Medical Systems). A total of 861 respiratory curves represented external...... measurements over 30 fraction treatment courses for 10 patients, and synchronous external/internal measurements in single sessions for seven patients. Variations in respiratory amplitude (simulated coaching) and external/internal phase shifts were simulated by perturbation with realistic values. Variations...

  17. Your Lungs and Respiratory System

    ... Lungs Print en español Tus pulmones y tu sistema respiratorio What's something that you do all day, ... of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for ...

  18. Methods of respiratory system investigation

    Rozenshtraukh, L.C.; Rybakova, N.I.; Vinner, M.G.

    1987-01-01

    Different methods of chest organs investigation are discussed in detail: roentgenoscopy, roentgenography, tomography and others. A detailed roentgenologic semiotics of every method is presented, as well as their comparative evaluation

  19. The respiratory system under weightlessness

    Paiva, M.; Engel, L. A.; Hughes, J. M. B.; Guy, H. J.; Prisk, G. K.; West, J. B.

    1987-01-01

    Studies of pulmonary functions at rest to be studied on Spacelab mission D-2 are introduced. Gravity dependence of the distribution of ventilation (single breath washout, multibreath washout-washin); chest wall shape and motion; and the vascular compartment (lung blood flow, capillary volume, liquid content, diffusive capacity) are discussed.

  20. Respiratory disease related mortality and morbidity on an island of Greece exposed to perlite and bentonite mining dust.

    Sampatakakis, Stefanos; Linos, Athena; Papadimitriou, Eleni; Petralias, Athanasios; Dalma, Archontoula; Papasaranti, Eirini Saranti; Christoforidou, Eleni; Stoltidis, Melina

    2013-10-14

    A morbidity and mortality study took place, focused on Milos Island, where perlite and bentonite mining sites are located. Official data concerning number and cause of deaths, regarding specific respiratory diseases and the total of respiratory diseases, for both Milos Island and the Cyclades Prefecture were used. Standardized Mortality Ratios (SMRs) were computed, adjusted specifically for age, gender and calendar year. Tests of linear trend were performed. By means of a predefined questionnaire, the morbidity rates of specific respiratory diseases in Milos, were compared to those of the municipality of Oinofita, an industrial region. Chi-square analysis was used and the confounding factors of age, gender and smoking were taken into account, by estimating binary logistic regression models. The SMRs for Pneumonia and Chronic Obstructive Pulmonary Disease (COPD) were found elevated for both genders, although they did not reach statistical significance. For the total of respiratory diseases, a statistically significant SMR was identified regarding the decade 1989-1998. The morbidity study revealed elevated and statistically significant Odds Ratios (ORs), associated with allergic rhinitis, pneumonia, COPD and bronchiectasis. An elevated OR was also identified for asthma. After controlling for age, gender and smoking, the ORs were statistically significant and towards the same direction.

  1. Respiratory Disease Related Mortality and Morbidity on an Island of Greece Exposed to Perlite and Bentonite Mining Dust

    Melina Stoltidis

    2013-10-01

    Full Text Available A morbidity and mortality study took place, focused on Milos Island, where perlite and bentonite mining sites are located. Official data concerning number and cause of deaths, regarding specific respiratory diseases and the total of respiratory diseases, for both Milos Island and the Cyclades Prefecture were used. Standardized Mortality Ratios (SMRs were computed, adjusted specifically for age, gender and calendar year. Tests of linear trend were performed. By means of a predefined questionnaire, the morbidity rates of specific respiratory diseases in Milos, were compared to those of the municipality of Oinofita, an industrial region. Chi-square analysis was used and the confounding factors of age, gender and smoking were taken into account, by estimating binary logistic regression models. The SMRs for Pneumonia and Chronic Obstructive Pulmonary Disease (COPD were found elevated for both genders, although they did not reach statistical significance. For the total of respiratory diseases, a statistically significant SMR was identified regarding the decade 1989–1998. The morbidity study revealed elevated and statistically significant Odds Ratios (ORs, associated with allergic rhinitis, pneumonia, COPD and bronchiectasis. An elevated OR was also identified for asthma. After controlling for age, gender and smoking, the ORs were statistically significant and towards the same direction.

  2. Estimation of Time-Dependent Reproduction Numbers for Porcine Reproductive and Respiratory Syndrome across Different Regions and Production Systems of the US.

    Arruda, Andréia G; Alkhamis, Moh A; VanderWaal, Kimberly; Morrison, Robert B; Perez, Andres M

    2017-01-01

    Porcine reproductive and respiratory syndrome (PRRS) is, arguably, the most impactful disease for the North American swine industry, due to its known considerable economic losses. The Swine Health Monitoring Project (SHMP) monitors and reports weekly new PRRS cases in 766 sow herds across the US. The time-dependent reproduction number (TD-R) is a measure of a pathogen's transmissibility. It may serve to capture and report PRRS virus (PRRSV) spread at the regional and system levels. The primary objective of the study here was to estimate the TD-R values for PRRSV using regional and system-level PRRS data, and to contrast it with commonly used metrics of disease, such as incidence estimates and space-time clusters. The second objective was to test whether the estimated TD-Rs were homogenous across four US regions. Retrospective monthly incidence data (2009-2016) were available from the SHMP. The dataset was divided into four regions based on location of participants, and demographic and environmental features, namely, South East (North Carolina), Upper Midwest East (UME, Minnesota/Iowa), Upper Midwest West (Nebraska/South Dakota), and South (Oklahoma panhandle). Generation time distributions were fit to incidence data for each region, and used to calculate the TD-Rs. The Kruskal-Wallis test was used to determine whether the median TD-Rs differed across the four areas. Furthermore, we used a space-time permutation model to assess spatial-temporal patterns for the four regions. Results showed TD-Rs were right skewed with median values close to "1" across all regions, confirming that PRRS has an overall endemic nature. Variation in the TD-R patterns was noted across regions and production systems. Statistically significant periods of PRRSV spread (TD-R > 1) were identified for all regions except UME. A minimum of three space-time clusters were detected for all regions considering the time period examined herein; and their overlap with "spreader events" identified by

  3. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems

    Panettieri, Vanessa; Wennberg, Berit; Gagliardi, Giovanna; Amor Duch, Maria; Ginjaume, Mercè; Lax, Ingmar

    2007-07-01

    The purpose of this work was to simulate with the Monte Carlo (MC) code PENELOPE the dose distribution in lung tumours including breathing motion in stereotactic body radiation therapy (SBRT). Two phantoms were modelled to simulate a pentagonal cross section with chestwall (unit density), lung (density 0.3 g cm-3) and two spherical tumours (unit density) of diameters respectively of 2 cm and 5 cm. The phase-space files (PSF) of four different SBRT field sizes of 6 MV from a Varian accelerator were calculated and used as beam sources to obtain both dose profiles and dose-volume histograms (DVHs) in different volumes of interest. Dose distributions were simulated for five beams impinging on the phantom. The simulations were conducted both for the static case and including the influence of respiratory motion. To reproduce the effect of breathing motion different simulations were performed keeping the beam fixed and displacing the phantom geometry in chosen positions in the cranial and caudal and left-right directions. The final result was obtained by combining the different position with two motion patterns. The MC results were compared with those obtained with three commercial treatment planning systems (TPSs), two based on the pencil beam (PB) algorithm, the TMS-HELAX (Nucletron, Sweden) and Eclipse (Varian Medical System, Palo Alto, CA), and one based on the collapsed cone algorithm (CC), Pinnacle3 (Philips). Some calculations were also carried out with the analytical anisotropic algorithm (AAA) in the Eclipse system. All calculations with the TPSs were performed without simulated breathing motion, according to clinical practice. In order to compare all the TPSs and MC an absolute dose calibration in Gy/MU was performed. The analysis shows that the dose (Gy/MU) in the central part of the gross tumour volume (GTV) is calculated for both tumour sizes with an accuracy of 2-3% with PB and CC algorithms, compared to MC. At the periphery of the GTV the TPSs overestimate

  4. Adult respiratory distress syndrome

    Svendsen, J.; Jespersen, J.; Skjoedt, T.

    1986-01-01

    Our present-day knowledge concerning the clinico-chemical and radiological findings in adult respiratory distress syndrome are described. Three typical case histories have been selected to illustrate this condition; they were due to multiple trauma or sepsis. It is stressed that radiology is in a key position for making the diagnosis and for observing the course of the illness. (orig) [de

  5. European Respiratory Society statement

    Miravitlles, Marc; Dirksen, Asger; Ferrarotti, Ilaria

    2017-01-01

    lung disease. A large proportion of individuals affected remain undiagnosed and therefore without access to appropriate care and treatment.The most recent international statement on AATD was published by the American Thoracic Society and the European Respiratory Society in 2003. Since then there has...

  6. Respiratory Syncytial Virus (RSV)

    Respiratory Syncytial Virus, or RSV, causes cold-like symptoms but can be serious for infants and older adults. In this podcast, CDC’s Dr. Eileen Schneider discusses this common virus and offers tips to prevent its spread.

  7. Respiratory Symptoms in Firefighters

    Greven, Frans E.; Rooyackers, Jos M.; Kerstjens, Huib A. M.; Heederik, Dick J.

    Background The aim of the present study was to determine the prevalence and risk factors associated with respiratory symptoms in common firefighters in the Netherlands. Methods A total of 1,330 firefighters from the municipal fire brigades of three provinces of the Netherlands were included in the

  8. Textbook of respiratory medicine

    Murray, J.F.; Nadel, J.

    1987-01-01

    This book presents a clinical reference of respiratory medicine. It also details basic science aspects of pulmonary physiology and describes recently developed, sophisticated diagnostic tools and therapeutic methods. It also covers anatomy, physiology, pharmacology, and pathology; microbiologic, radiologic, nuclear medicine, and biopsy methods for diagnosis

  9. ARDS (Acute Respiratory Distress Syndrome)

    ... Also known as What Is ARDS, or acute respiratory distress syndrome, is a lung condition that leads ... treat ARDS. Other Names Acute lung injury Adult respiratory distress syndrome Increased-permeability pulmonary edema Noncardiac pulmonary ...

  10. Middle East Respiratory Syndrome (MERS)

    Middle East Respiratory Syndrome Coronavirus; MERS-CoV; Novel coronavirus; nCoV ... for Disease Control and Prevention website. Middle East Respiratory Syndrome (MERS): Frequently asked questions and answers. www. ...

  11. Acute respiratory infections at children

    Delyagin, V.

    2009-01-01

    The common signs of virus respiratory diseases, role of pathological inclination to infections, value of immunodeficiency are presented at lecture. Features of most often meeting respiratory virus infections are given.

  12. Respiratory Management in the Patient with Spinal Cord Injury

    Rita Galeiras Vázquez

    2013-01-01

    Full Text Available Spinal cord injuries (SCIs often lead to impairment of the respiratory system and, consequently, restrictive respiratory changes. Paresis or paralysis of the respiratory muscles can lead to respiratory insufficiency, which is dependent on the level and completeness of the injury. Respiratory complications include hypoventilation, a reduction in surfactant production, mucus plugging, atelectasis, and pneumonia. Vital capacity (VC is an indicator of overall pulmonary function; patients with severely impaired VC may require assisted ventilation. It is best to proceed with intubation under controlled circumstances rather than waiting until the condition becomes an emergency. Mechanical ventilation can adversely affect the structure and function of the diaphragm. Early tracheostomy following short orotracheal intubation is probably beneficial in selected patients. Weaning should start as soon as possible, and the best modality is progressive ventilator-free breathing (PVFB. Appropriate candidates can sometimes be freed from mechanical ventilation by electrical stimulation. Respiratory muscle training regimens may improve patients’ inspiratory function following a SCI.

  13. Inhaled Antibiotic Therapy in Chronic Respiratory Diseases

    Diego J. Maselli

    2017-05-01

    Full Text Available The management of patients with chronic respiratory diseases affected by difficult to treat infections has become a challenge in clinical practice. Conditions such as cystic fibrosis (CF and non-CF bronchiectasis require extensive treatment strategies to deal with multidrug resistant pathogens that include Pseudomonas aeruginosa, Methicillin-resistant Staphylococcus aureus, Burkholderia species and non-tuberculous Mycobacteria (NTM. These challenges prompted scientists to deliver antimicrobial agents through the pulmonary system by using inhaled, aerosolized or nebulized antibiotics. Subsequent research advances focused on the development of antibiotic agents able to achieve high tissue concentrations capable of reducing the bacterial load of difficult-to-treat organisms in hosts with chronic respiratory conditions. In this review, we focus on the evidence regarding the use of antibiotic therapies administered through the respiratory system via inhalation, nebulization or aerosolization, specifically in patients with chronic respiratory diseases that include CF, non-CF bronchiectasis and NTM. However, further research is required to address the potential benefits, mechanisms of action and applications of inhaled antibiotics for the management of difficult-to-treat infections in patients with chronic respiratory diseases.

  14. Assessment of respiratory involvement in children with mucoplysaccharidosis using pulmonary function tests

    Mona M. El Falaki

    2014-01-01

    Conclusions: Evaluation and follow up of patients with MPS using pulmonary function tests are essential to detect early involvement of respiratory system and hence start treatment for respiratory complications early in the course of the disease.

  15. Surfactant Protein D in Respiratory and Non-Respiratory Diseases

    Sorensen, Grith L.

    2018-01-01

    Surfactant protein D (SP-D) is a multimeric collectin that is involved in innate immune defense and expressed in pulmonary, as well as non-pulmonary, epithelia. SP-D exerts antimicrobial effects and dampens inflammation through direct microbial interactions and modulation of host cell responses via a series of cellular receptors. However, low protein concentrations, genetic variation, biochemical modification, and proteolytic breakdown can induce decomposition of multimeric SP-D into low-molecular weight forms, which may induce pro-inflammatory SP-D signaling. Multimeric SP-D can decompose into trimeric SP-D, and this process, and total SP-D levels, are partly determined by variation within the SP-D gene, SFTPD. SP-D has been implicated in the development of respiratory diseases including respiratory distress syndrome, bronchopulmonary dysplasia, allergic asthma, and chronic obstructive pulmonary disease. Disease-induced breakdown or modifications of SP-D facilitate its systemic leakage from the lung, and circulatory SP-D is a promising biomarker for lung injury. Moreover, studies in preclinical animal models have demonstrated that local pulmonary treatment with recombinant SP-D is beneficial in these diseases. In recent years, SP-D has been shown to exert antimicrobial and anti-inflammatory effects in various non-pulmonary organs and to have effects on lipid metabolism and pro-inflammatory effects in vessel walls, which enhance the risk of atherosclerosis. A common SFTPD polymorphism is associated with atherosclerosis and diabetes, and SP-D has been associated with metabolic disorders because of its effects in the endothelium and adipocytes and its obesity-dampening properties. This review summarizes and discusses the reported genetic associations of SP-D with disease and the clinical utility of circulating SP-D for respiratory disease prognosis. Moreover, basic research on the mechanistic links between SP-D and respiratory, cardiovascular, and metabolic diseases

  16. SugE belongs to the small multidrug resistance (SMR) protein family involved in tributyltin (TBT) biodegradation and bioremediation by alkaliphilic Stenotrophomonas chelatiphaga HS2.

    Hassan, Hamdy A

    2018-03-01

    Tributyltin (TBT) used in a variety of industrial processes, subsequent discharge into the environment, its fate, toxicity and human exposure are topics of current concern. TBT degradation by alkaliphilic bacteria may be a key factor in the remediation of TBT in high pH contaminated sites. In this study, Stenotrophomonas chelatiphaga HS2 were isolated and identified from TBT contaminated site in Mediterranean Sea. S. chelatiphaga HS2 has vigor capability to transform TBT into dibutyltin and monobutyltin (DBT and MBT) at pH 9 and 7% NaCl (w/v). A gene was amplified and characterized from strain HS2 as SugE protein belongs to SMR protein family, a reverse transcription polymerase chain reaction analysis confirmed that SugE protein involved in the TBT degradation by HS2 strain. TBT bioremediation was investigated in stimulated TBT contaminated sediment samples (pH 9) using S chelatiphaga HS2 in association with E. coli BL21 (DE3)-pET28a(+)-sugE instead of S chelatiphaga HS2 alone reduced significantly the TBT half-life from 12d to 5d, although no TBT degradation appeared using E. coli BL21 (DE3)-pET28a(+)-sugE alone. This finding indicated that SugE gene increased the rate and degraded amount of TBT and is necessary in enhancing TBT bioremediation. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparative proteomics analysis of the rice roots colonized by Herbaspirillum seropedicae strain SmR1 reveals induction of the methionine recycling in the plant host.

    Alberton, Dayane; Müller-Santos, Marcelo; Brusamarello-Santos, Liziane Cristina Campos; Valdameri, Glaucio; Cordeiro, Fabio Aparecido; Yates, Marshall Geoffrey; de Oliveira Pedrosa, Fabio; de Souza, Emanuel Maltempi

    2013-11-01

    Although the use of plant growth-promoting bacteria in agriculture is a reality, the molecular basis of plant-bacterial interaction is still poorly understood. We used a proteomic approach to study the mechanisms of interaction of Herbaspirillum seropedicae SmR1 with rice. Root proteins of rice seedlings inoculated or noninoculated with H. seropedicae were separated by 2-D electrophoresis. Differentially expressed proteins were identified by MALDI-TOF/TOF and MASCOT program. Among the identified proteins of H. seropedicae, the dinitrogenase reductase NifH and glutamine synthetase GlnA, which participate in nitrogen fixation and ammonium assimilation, respectively, were the most abundant. The rice proteins up-regulated included the S-adenosylmethionine synthetase, methylthioribose kinase, and acireductone dioxygenase 1, all of which are involved in the methionine recycling. S-Adenosylmethionine synthetase catalyzes the synthesis of S-adenosylmethionine, an intermediate used in transmethylation reactions and in ethylene, polyamine, and phytosiderophore biosynthesis. RT-qPCR analysis also confirmed that the methionine recycling and phytosiderophore biosynthesis genes were up-regulated, while ACC oxidase mRNA level was down-regulated in rice roots colonized by bacteria. In agreement with these results, ethylene production was reduced approximately three-fold in rice roots colonized by H. seropedicae. The results suggest that H. seropedicae stimulates methionine recycling and phytosiderophore synthesis and diminishes ethylene synthesis in rice roots.

  18. Comparison of Sensorimotor Rhythm (SMR) and Beta Training on Selective Attention and Symptoms in Children with Attention Deficit/Hyperactivity Disorder (ADHD): A Trend Report.

    Mohammadi, Mohammad Reza; Malmir, Nastaran; Khaleghi, Ali; Aminiorani, Majd

    2015-06-01

    The aim of this study was to assess and compare the effect of two neurofeedback protocols (SMR/theta and beta/theta) on ADHD symptoms, selective attention and EEG (electroencephalogram) parameters in children with ADHD. The sample consisted of 16 children (9-15 year old: 13 boys; 3 girls) with ADHD-combined type (ADHD-C). All of children used methylphenidate (MPH) during the study. The neurofeedback training consisted of two phases of 15 sessions, each lasting 45 minutes. In the first phase, participants were trained to enhance sensorimotor rhythm (12-15 Hz) and reduce theta activity (4-8 Hz) at C4 and in the second phase; they had to increase beta (15-18 Hz) and reduce theta activity at C3. Assessments consisted of d2 attention endurance test, ADHD rating scale (parent form) at three time periods: before, middle and the end of the training. EEG signals were recorded just before and after the training. Based on parents' reports, inattention after beta/theta training, and hyperactivity/impulsivity were improved after the end of the training. All subscales of d2 test were improved except for the difference between maximum and minimum responses. However, EEG analysis showed no significant differences. Neurofeedback in conjunction with Methylphenidate may cause further improvement in ADHD symptoms reported by parents and selective attention without long-term impact on EEG patterns. However, determining the exact relationship between EEG parameters, neurofeedback protocols and ADHD symptoms remain unclear.

  19. Climate change and respiratory disease: European Respiratory Society position statement.

    Ayres, J G; Forsberg, B; Annesi-Maesano, I; Dey, R; Ebi, K L; Helms, P J; Medina-Ramón, M; Windt, M; Forastiere, F

    2009-08-01

    Climate change will affect individuals with pre-existing respiratory disease, but the extent of the effect remains unclear. The present position statement was developed on behalf of the European Respiratory Society in order to identify areas of concern arising from climate change for individuals with respiratory disease, healthcare workers in the respiratory sector and policy makers. The statement was developed following a 2-day workshop held in Leuven (Belgium) in March 2008. Key areas of concern for the respiratory community arising from climate change are discussed and recommendations made to address gaps in knowledge. The most important recommendation was the development of more accurate predictive models for predicting the impact of climate change on respiratory health. Respiratory healthcare workers also have an advocatory role in persuading governments and the European Union to maintain awareness and appropriate actions with respect to climate change, and these areas are also discussed in the position statement.

  20. Incremental exercise test performance with and without a respiratory ...

    Incremental exercise test performance with and without a respiratory gas collection system. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  1. Influence of chemoreflexes on respiratory variability in healthy subjects

    van den Aardweg, Joost G.; Karemaker, John M.

    2002-01-01

    The background of this study was the hypothesis that respiratory variability is influenced by chemoreflex regulation, In search for periodicities in the variability due to instability of the respiratory control system, spectral analysis was applied to breath-to-breath variables in 19 healthy

  2. Evaluation of respiratory pattern during respiratory-gated radiotherapy

    Dobashi, Suguru; Mori, Shinichiro

    2014-01-01

    The respiratory cycle is not strictly regular, and generally varies in amplitude and period from one cycle to the next. We evaluated the characteristics of respiratory patterns acquired during respiratory gating treatment in more than 300 patients. A total 331 patients treated with respiratory-gated carbon-ion beam therapy were selected from a group of patients with thoracic and abdominal conditions. Respiratory data were acquired for a total of 3,171 fractions using an external respiratory sensing monitor and evaluated for respiratory cycle, duty cycle, magnitude of baseline drift, and intrafractional/interfractional peak inhalation/exhalation positional variation. Results for the treated anatomical sites and patient positioning were compared. Mean ± SD respiratory cycle averaged over all patients was 4.1 ± 1.3 s. Mean ± SD duty cycle averaged over all patients was 36.5 ± 7.3 %. Two types of baseline drift were seen, the first decremental and the second incremental. For respiratory peak variation, the mean intrafractional variation in peak-inhalation position relative to the amplitude in the first respiratory cycle (15.5 ± 9.3 %) was significantly larger than that in exhalation (7.5 ± 4.6 %). Interfractional variations in inhalation (17.2 ± 18.5 %) were also significantly greater than those in exhalation (9.4 ± 10.0 %). Statistically significant differences were observed between patients in the supine position and those in the prone position in mean respiratory cycle, duty cycle, and intra-/interfractional variations. We quantified the characteristics of the respiratory curve based on a large number of respiratory data obtained during treatment. These results might be useful in improving the accuracy of respiratory-gated treatment.

  3. Evaluation of an intranasal virosomal vaccine against respiratory syncytial virus in mice: effect of TLR2 and NOD2 ligands on induction of systemic and mucosal immune responses.

    Muhammad Shafique

    Full Text Available INTRODUCTION: RSV infection remains a serious threat to newborns and the elderly. Currently, there is no vaccine available to prevent RSV infection. A mucosal RSV vaccine would be attractive as it could induce mucosal as well as systemic antibodies, capable of protecting both the upper and lower respiratory tract. Previously, we reported on a virosomal RSV vaccine for intramuscular injection with intrinsic adjuvant properties mediated by an incorporated lipophilic Toll-like receptor 2 (TLR2 ligand. However, it has not been investigated whether this virosomal RSV vaccine candidate would be suitable for use in mucosal immunization strategies and if additional incorporation of other innate receptor ligands, like NOD2-ligand, could further enhance the immunogenicity and protective efficacy of the vaccine. OBJECTIVE: To explore if intranasal (IN immunization with a virosomal RSV vaccine, supplemented with TLR2 and/or NOD2-ligands, is an effective strategy to induce RSV-specific immunity. METHODS: We produced RSV-virosomes carrying TLR2 (Pam3CSK4 and/or NOD2 (L18-MDP ligands. We tested the immunopotentiating properties of these virosomes in vitro, using TLR2- and/or NOD2-ligand-responsive murine and human cell lines, and in vivo by assessing induction of protective antibody and cellular responses upon IN immunization of BALB/c mice. RESULTS: Incorporation of Pam3CSK4 and/or L18-MDP potentiates the capacity of virosomes to activate (antigen-presenting cells in vitro, as demonstrated by NF-κB induction. In vivo, incorporation of Pam3CSK4 in virosomes boosted serum IgG antibody responses and mucosal antibody responses after IN immunization. While L18-MDP alone was ineffective, incorporation of L18-MDP in Pam3CSK4-carrying virosomes further boosted mucosal antibody responses. Finally, IN immunization with adjuvanted virosomes, particularly Pam3CSK4/L18-MDP-adjuvanted-virosomes, protected mice against infection with RSV, without priming for enhanced

  4. Panic disorder and the respiratory system: clinical subtype and challenge tests Transtorno do pânico e sistema respiratório: subtipo clínico e testes de provocação

    Rafael C. Freire

    2012-06-01

    Full Text Available INTRODUCTION: Respiratory changes are associated with anxiety disorders, particularly panic disorder (PD. The stimulation of respiration in PD patients during panic attacks is well documented in the literature, and a number of abnormalities in respiration, such as enhanced CO2 sensitivity, have been detected in PD patients. Investigators hypothesized that there is a fundamental abnormality in the physiological mechanisms that control breathing in PD. METHODS: The authors searched for articles regarding the connection between the respiratory system and PD, more specifically papers on respiratory challenges, respiratory subtype, and current mechanistic concepts. CONCLUSIONS: Recent evidences support the presence of subclinical changes in respiration and other functions related to body homeostasis in PD patients. The fear network, comprising the hippocampus, medial prefrontal cortex, amygdala and its brainstem projections, may be abnormally sensitive in PD patients, and respiratory stimulants like CO2 may trigger panic attacks. Studies indicate that PD patients with dominant respiratory symptoms are particularly sensitive to respiratory tests compared to those who do not manifest dominant respiratory symptoms, representing a distinct subtype. The evidence of changes in several neurochemical systems might be the expression of the complex interaction among brain circuitsINTRODUÇÃO: As anormalidades respiratórias estão associadas a transtornos de ansiedade, especialmente ao transtorno do pânico (TP. A estimulação respiratória em pacientes com TP durante os ataques de pânico está bem documentada na literatura, e vários problemas respiratórios como uma elevada sensibilidade ao CO2 foram detectados em pacientes com TP. Os pesquisadores levantam a hipótese de que existe um distúrbio fundamental nos mecanismos fisiológicos que controlam a respiração no TP. MÉTODOS: Os autores pesquisaram artigos sobre a conexão entre o sistema respirat

  5. Spinal Metaplasticity in Respiratory Motor Control

    Gordon S Mitchell

    2015-02-01

    Full Text Available A hallmark feature of the neural system controlling breathing is its ability to exhibit plasticity. Less appreciated is the ability to exhibit metaplasticity, a change in the capacity to express plasticity (ie. plastic plasticity. Recent advances in our understanding of cellular mechanisms giving rise to respiratory motor plasticity lay the groundwork for (ongoing investigations of metaplasticity. This detailed understanding of respiratory metaplasticity will be essential as we harness metaplasticity to restore breathing capacity in clinical disorders that compromise breathing, such as cervical spinal injury, motor neuron disease and other neuromuscular diseases. In this brief review, we discuss key examples of metaplasticity in respiratory motor control, and our current understanding of mechanisms giving rise to spinal plasticity and metaplasticity in phrenic motor output; particularly after pre-conditioning with intermittent hypoxia. Progress in this area has led to the realization that similar mechanisms are operative in other spinal motor networks, including those governing limb movement. Further, these mechanisms can be harnessed to restore respiratory and non-respiratory motor function after spinal injury.

  6. Ocular Tropism of Respiratory Viruses

    Rota, Paul A.; Tumpey, Terrence M.

    2013-01-01

    SUMMARY Respiratory viruses (including adenovirus, influenza virus, respiratory syncytial virus, coronavirus, and rhinovirus) cause a broad spectrum of disease in humans, ranging from mild influenza-like symptoms to acute respiratory failure. While species D adenoviruses and subtype H7 influenza viruses are known to possess an ocular tropism, documented human ocular disease has been reported following infection with all principal respiratory viruses. In this review, we describe the anatomical proximity and cellular receptor distribution between ocular and respiratory tissues. All major respiratory viruses and their association with human ocular disease are discussed. Research utilizing in vitro and in vivo models to study the ability of respiratory viruses to use the eye as a portal of entry as well as a primary site of virus replication is highlighted. Identification of shared receptor-binding preferences, host responses, and laboratory modeling protocols among these viruses provides a needed bridge between clinical and laboratory studies of virus tropism. PMID:23471620

  7. Cellular immune responses to respiratory viruses

    van Helden, M.J.G.

    2011-01-01

    When a respiratory virus successfully infects the lungs, cascades of immune responses are initiated aimed to remove the pathogen. Immediate non-specific protection is provided by the innate immune system and this reduces the viral load during the first days of infection. The adaptive immune response

  8. Adult respiratory distress syndrome

    Murphy, C.H.; Colvin, R.S.

    1987-01-01

    Due to improved emergency resuscitation procedures, and with advancing medical technology in the field of critical care, an increasing number of patients survive the acute phase of shock and catastrophic trauma. Patients who previously died of massive sepsis, hypovolemic or hypotensive shock, multiple fractures, aspiration, toxic inhalation, and massive embolism are now surviving long enough to develop previously unsuspected and unrecognized secondary effects. With increasing frequency, clinicians are recognizing the clinical and radiographic manifestations of pathologic changes in the lungs occurring secondary to various types of massive insult. This paper gives a list of diseases that have been shown to precipitate or predispose to diffuse lung damage. Various terms have been used to describe the lung damage and respiratory failure secondary to these conditions. The term adult respiratory distress syndrome (ARDS) is applied to several cases of sudden respiratory failure in patients with previously healthy lungs following various types of trauma or shock. Numerous investigations and experiments have studied the pathologic changes in ARDS, and, while there is still no clear indication of why it develops, there is now some correlation of the sequential pathologic developments with the clinical and radiographic changes

  9. Extracorporeal respiratory support in adult patients

    Thiago Gomes Romano

    Full Text Available ABSTRACT In patients with severe respiratory failure, either hypoxemic or hypercapnic, life support with mechanical ventilation alone can be insufficient to meet their needs, especially if one tries to avoid ventilator settings that can cause injury to the lungs. In those patients, extracorporeal membrane oxygenation (ECMO, which is also very effective in removing carbon dioxide from the blood, can provide life support, allowing the application of protective lung ventilation. In this review article, we aim to explore some of the most relevant aspects of using ECMO for respiratory support. We discuss the history of respiratory support using ECMO in adults, as well as the clinical evidence; costs; indications; installation of the equipment; ventilator settings; daily care of the patient and the system; common troubleshooting; weaning; and discontinuation.

  10. Thermo-economic analysis of integrated membrane-SMR ITM-oxy-combustion hydrogen and power production plant

    Sanusi, Yinka S.; Mokheimer, Esmail M.A.; Habib, Mohamed A.

    2017-01-01

    Highlights: •A methane reforming reactor integrated to an oxy-combustion plant is proposed. •Co-production of power and hydrogen was investigated and presented. •Optimal thermo-economic operating conditions of the system were identified and presented. •The ion transport membrane oxygen separation unit has the highest capital cost. •The combustor has the highest exergy destruction. -- Abstract: The demand for hydrogen has greatly increased in the last decade due to the stringent regulations enacted to address environmental pollution concerns. Natural gas reforming is currently the most mature technology for large-scale hydrogen production. However, it is usually associated with greenhouse gas emissions. As part of the strategies to reduce greenhouse gas emissions, new designs need to be developed to integrate hydrogen production facilities that are based on natural gas reforming with carbon capture facilities. In this study, we carried out energy, exergy and economic analysis of hydrogen production in a steam methane reforming reactor integrated with an oxy-combustion plant for co-production of power and hydrogen. The results show that the overall system efficiency and hydrogen production efficiency monotonically increase with increasing the combustor exit temperature (CET), increasing the amount of hydrogen extracted and decreasing the auxiliary fuel added to the system. The optimal thermo-economic operating conditions of the system were obtained as reformer pressure of 15 bar, auxiliary fuel factor of 0.8 and hydrogen extraction factor of 0.6. The production cost of hydrogen using the proposed system, under these optimal operating conditions, is within the range suggested by the International Energy Agency (IEA). Further analysis shows that the capital cost of the membrane-air separation unit (ITM) has the major share in the total investment cost of the system and constitutes 37% of the total capital cost of the system at the CET of 1500 K. The exergy

  11. Titration of High Frequency Percussive Ventilation by means of real-time monitoring of the viscoelastic respiratory system properties and endotracheal tubes pressure drop.

    Lucangelo, Umberto

    2014-01-01

    2012/2013 The use of High Frequency Percussive Ventilation (HFPV) is still debated although this type of non-conventional ventilation has proven effective and safe in patients with acute respiratory failure. In the clinical practice, HFPV is not an intuitive ventilatory modality and the absence of real-time delivered volume monitoring produces disaffection among the physicians. Avoiding the "volutrauma" is the cornerstone of the "protective ventilation strategy", which assumes a cons...

  12. Retrospective data-driven respiratory gating for PET/CT

    Schleyer, Paul J; O'Doherty, Michael J; Barrington, Sally F; Marsden, Paul K

    2009-01-01

    Respiratory motion can adversely affect both PET and CT acquisitions. Respiratory gating allows an acquisition to be divided into a series of motion-reduced bins according to the respiratory signal, which is typically hardware acquired. In order that the effects of motion can potentially be corrected for, we have developed a novel, automatic, data-driven gating method which retrospectively derives the respiratory signal from the acquired PET and CT data. PET data are acquired in listmode and analysed in sinogram space, and CT data are acquired in cine mode and analysed in image space. Spectral analysis is used to identify regions within the CT and PET data which are subject to respiratory motion, and the variation of counts within these regions is used to estimate the respiratory signal. Amplitude binning is then used to create motion-reduced PET and CT frames. The method was demonstrated with four patient datasets acquired on a 4-slice PET/CT system. To assess the accuracy of the data-derived respiratory signal, a hardware-based signal was acquired for comparison. Data-driven gating was successfully performed on PET and CT datasets for all four patients. Gated images demonstrated respiratory motion throughout the bin sequences for all PET and CT series, and image analysis and direct comparison of the traces derived from the data-driven method with the hardware-acquired traces indicated accurate recovery of the respiratory signal.

  13. Controlled cross-over study in normal subjects of naloxone-preceding-lactate infusions; respiratory and subjective responses: relationship to endogenous opioid system, suffocation false alarm theory and childhood parental loss.

    Preter, M; Lee, S H; Petkova, E; Vannucci, M; Kim, S; Klein, D F

    2011-02-01

    The expanded suffocation false alarm theory (SFA) hypothesizes that dysfunction in endogenous opioidergic regulation increases sensitivity to CO2, separation distress and panic attacks. In panic disorder (PD) patients, both spontaneous clinical panics and lactate-induced panics markedly increase tidal volume (TV), whereas normals have a lesser effect, possibly due to their intact endogenous opioid system. We hypothesized that impairing the opioidergic system by naloxone could make normal controls parallel PD patients' response when lactate challenged. Whether actual separations and losses during childhood (childhood parental loss, CPL) affected naloxone-induced respiratory contrasts was explored. Subjective panic-like symptoms were analyzed although pilot work indicated that the subjective aspect of anxious panic was not well modeled by this specific protocol. Randomized cross-over sequences of intravenous naloxone (2 mg/kg) followed by lactate (10 mg/kg), or saline followed by lactate, were given to 25 volunteers. Respiratory physiology was objectively recorded by the LifeShirt. Subjective symptomatology was also recorded. Impairment of the endogenous opioid system by naloxone accentuates TV and symptomatic response to lactate. This interaction is substantially lessened by CPL. Opioidergic dysregulation may underlie respiratory pathophysiology and suffocation sensitivity in PD. Comparing specific anti-panic medications with ineffective anti-panic agents (e.g. propranolol) can test the specificity of the naloxone+lactate model. A screen for putative anti-panic agents and a new pharmacotherapeutic approach are suggested. Heuristically, the experimental unveiling of the endogenous opioid system impairing effects of CPL and separation in normal adults opens a new experimental, investigatory area.

  14. Controlled cross-over study in normal subjects of naloxone-preceding-lactate infusions; respiratory and subjective responses: relationship to endogenous opioid system, suffocation false alarm theory and childhood parental loss

    Preter, M.; Lee, S. H.; Petkova, E.; Vannucci, M.; Kim, S.; Klein, D. F.

    2015-01-01

    Background The expanded suffocation false alarm theory (SFA) hypothesizes that dysfunction in endogenous opioidergic regulation increases sensitivity to CO2, separation distress and panic attacks. In panic disorder (PD) patients, both spontaneous clinical panics and lactate-induced panics markedly increase tidal volume (TV), whereas normals have a lesser effect, possibly due to their intact endogenous opioid system. We hypothesized that impairing the opioidergic system by naloxone could make normal controls parallel PD patients' response when lactate challenged. Whether actual separations and losses during childhood (childhood parental loss, CPL) affected naloxone-induced respiratory contrasts was explored. Subjective panic-like symptoms were analyzed although pilot work indicated that the subjective aspect of anxious panic was not well modeled by this specific protocol. Method Randomized cross-over sequences of intravenous naloxone (2 mg/kg) followed by lactate (10 mg/kg), or saline followed by lactate, were given to 25 volunteers. Respiratory physiology was objectively recorded by the LifeShirt. Subjective symptomatology was also recorded. Results Impairment of the endogenous opioid system by naloxone accentuates TV and symptomatic response to lactate. This interaction is substantially lessened by CPL. Conclusions Opioidergic dysregulation may underlie respiratory pathophysiology and suffocation sensitivity in PD. Comparing specific anti-panic medications with ineffective anti-panic agents (e.g. propranolol) can test the specificity of the naloxone + lactate model. A screen for putative anti-panic agents and a new pharmacotherapeutic approach are suggested. Heuristically, the experimental unveiling of the endogenous opioid system impairing effects of CPL and separation in normal adults opens a new experimental, investigatory area. PMID:20444308

  15. Quality verification for respiratory gated proton therapy

    Kim, Eun Sook; Jang, Yo Jong; Park, Ji Yeon; Kang, Dong Yun; Yeom, Doo Seok

    2013-01-01

    To verify accuracy of respiratory gated proton therapy by measuring and analyzing proton beam delivered when respiratory gated proton therapy is being performed in our institute. The plan data of 3 patients who took respiratory gated proton therapy were used to deliver proton beam from proton therapy system. The manufactured moving phantom was used to apply respiratory gating system to reproduce proton beam which was partially irradiated. The key characteristics of proton beam, range, spreat-out Bragg peak (SOBP) and output factor were measured 5 times and the same categories were measured in the continuous proton beam which was not performed with respiratory gating system. Multi-layer ionization chamber was used to measure range and SOBP, and Scanditronix Wellhofer and farmer chamber was used to measure output factor. The average ranges of 3 patients (A, B, C), who had taken respiratory gated proton therapy or not, were (A) 7.226, 7.230, (B) 12.216, 12.220 and (C) 19.918, 19.920 g/cm 2 and average SOBP were (A) 4.950, 4.940, (B) 6.496, 6.512 and (C) 8.486, 8.490 g/cm 2 . And average output factor were (A) 0.985, 0.984 (B) 1.026, 1.027 and (C) 1.138, 1.136 cGy/MU. The differences of average range were -0.004, -0.004, -0.002 g/cm 2 , that of SOBP were 0.010, -0.016, -0.004 g/cm 2 and that of output factor were 0.001, -0.001, 0.002 cGy/MU. It is observed that the range, SOBP and output factor of proton beam delivered when respiratory gated proton therapy is being performed have the same beam quality with no significant difference compared to the proton beam which was continuously irradiated. Therefore, this study verified the quality of proton beam delivered when respiratory gated proton therapy and confirmed the accuracy of proton therapy using this

  16. Respiratory cancer database: An open access database of respiratory cancer gene and miRNA.

    Choubey, Jyotsna; Choudhari, Jyoti Kant; Patel, Ashish; Verma, Mukesh Kumar

    2017-01-01

    Respiratory cancer database (RespCanDB) is a genomic and proteomic database of cancer of respiratory organ. It also includes the information of medicinal plants used for the treatment of various respiratory cancers with structure of its active constituents as well as pharmacological and chemical information of drug associated with various respiratory cancers. Data in RespCanDB has been manually collected from published research article and from other databases. Data has been integrated using MySQL an object-relational database management system. MySQL manages all data in the back-end and provides commands to retrieve and store the data into the database. The web interface of database has been built in ASP. RespCanDB is expected to contribute to the understanding of scientific community regarding respiratory cancer biology as well as developments of new way of diagnosing and treating respiratory cancer. Currently, the database consist the oncogenomic information of lung cancer, laryngeal cancer, and nasopharyngeal cancer. Data for other cancers, such as oral and tracheal cancers, will be added in the near future. The URL of RespCanDB is http://ridb.subdic-bioinformatics-nitrr.in/.

  17. Respiratory muscle training for cystic fibrosis.

    Hilton, Nathan; Solis-Moya, Arturo

    2018-05-24

    Cystic fibrosis is the most common autosomal recessive disease in white populations, and causes respiratory dysfunction in the majority of individuals. Numerous types of respiratory muscle training to improve respiratory function and health-related quality of life in people with cystic fibrosis have been reported in the literature. Hence a systematic review of the literature is needed to establish the effectiveness of respiratory muscle training (either inspiratory or expiratory muscle training) on clinical outcomes in cystic fibrosis. This is an update of a previously published review. To determine the effectiveness of respiratory muscle training on clinical outcomes in people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials register comprising of references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Date of most recent search: 17 April 2018.A hand search of the Journal of Cystic Fibrosis and Pediatric Pulmonology was performed, along with an electronic search of online trial databases up until 07 May 2018. Randomised controlled studies comparing respiratory muscle training with a control group in people with cystic fibrosis. Review authors independently selected articles for inclusion, evaluated the methodological quality of the studies, and extracted data. Additional information was sought from trial authors where necessary. The quality of the evidence was assessed using the GRADE system MAIN RESULTS: Authors identified 19 studies, of which nine studies with 202 participants met the review's inclusion criteria. There was wide variation in the methodological and written quality of the included studies. Four of the nine included studies were published as abstracts only and lacking concise details, thus limiting the information available. Seven studies were parallel studies and two of a cross-over design. Respiratory

  18. 一种接口兼容的非接触式呼吸信号检测系统的设计与研究%Design and Research of an Interface Compatible Non-contacting Respiratory Signal Detection System

    宋奎; 齐家俊; 林涛; 张逸

    2011-01-01

    Respiration-induced displacements of organs greatly affect the safety and efficiency of high intensity focused ultrasound (HIFU) tumor therapy system. The key to solve this problem is accurate, real-time detection of respiratory signals. The present study gives a new design of an interface compatible non-contacting respiratory signal detection system using the method of irradiating the laser beam onto certain region of the surface of human body that is intensely influenced by the breathing movements (mostly the breast or the dorsum) at a certain angle, and meanwhile using a camera to aquire information from the location of the laser projection. Then we can draw a curve of the location of laser projection versus time base, that is the respiration curve. This respiratory signal detection method is non-contacting, interface compatible and easy to be integrated into the treatment system.%呼吸运动引发的体内脏器移位极大影响高强度聚焦超声(HIFU)肿瘤治疗系统的安全性和治疗效率.解决这一问题的关键是实时、准确的呼吸信号检测.以一定角度,用激光束在人体表受呼吸运动影响较大的部位(一般是胸部或背部)投射激光点,用摄像机采集激光点位置信息.描绘激光点位置与采集时刻的关系曲线,即呼吸曲线.该呼吸信号检测方法为非接触式,同时具有接口兼容性好的优点,便于集成到治疗系统中.

  19. Effects of nasal or pulmonary delivered treatments with an adenovirus vectored interferon (mDEF201 on respiratory and systemic infections in mice caused by cowpox and vaccinia viruses.

    Donald F Smee

    Full Text Available An adenovirus 5 vector encoding for mouse interferon alpha, subtype 5 (mDEF201 was evaluated for efficacy against lethal cowpox (Brighton strain and vaccinia (WR strain virus respiratory and systemic infections in mice. Two routes of mDEF201 administration were used, nasal sinus (5-µl and pulmonary (50-µl, to compare differences in efficacy, since the preferred treatment of humans would be in a relatively small volume delivered intranasally. Lower respiratory infections (LRI, upper respiratory infections (URI, and systemic infections were induced by 50-µl intranasal, 10-µl intranasal, and 100-µl intraperitoneal virus challenges, respectively. mDEF201 treatments were given prophylactically either 24 h (short term or 56d (long-term prior to virus challenge. Single nasal sinus treatments of 10(6 and 10(7 PFU/mouse of mDEF201 protected all mice from vaccinia-induced LRI mortality (comparable to published studies with pulmonary delivered mDEF201. Systemic vaccinia infections responded significantly better to nasal sinus delivered mDEF201 than to pulmonary treatments. Cowpox LRI infections responded to 10(7 mDEF201 treatments, but a 10(6 dose was only weakly protective. Cowpox URI infections were equally treatable by nasal sinus and pulmonary delivered mDEF201 at 10(7 PFU/mouse. Dose-responsive prophylaxis with mDEF201, given one time only 56 d prior to initiating a vaccinia virus LRI infection, was 100% protective from 10(5 to 10(7 PFU/mouse. Improvements in lung hemorrhage score and lung weight were evident, as were decreases in liver, lung, and spleen virus titers. Thus, mDEF201 was able to treat different vaccinia and cowpox virus infections using both nasal sinus and pulmonary treatment regimens, supporting its development for humans.

  20. Prevention of Nosocomial Respiratory Infections

    N. A. Karpun

    2007-01-01

    Full Text Available Objective: to evaluate the efficiency of an extended package of preventive measures on the incidence of nosocomial respiratory infections in surgical patients at an intensive care unit (ICU. Subjects and methods. The study included 809 patients aged 35 to 80 years. A study group comprised 494 patients in whom an extended package of preventive measures was implemented during 7 months (March-September. A control group consisted of 315 patients treated in 2004 in the same period of time (March-September. The groups were stratified by age, gender, underlying diseases, and APACHE-2 and SOFA scores. The extended package of anti-infectious measures involved a high air purification in ICUs («Flow-M» technology, routine use of ventilatory filters, closed aspiration systems with a built-in antibacterial filter under artificial ventilation for over 2 days. Results. The proposed technologies could reduce the frequency of tracheobronchitis and ventilator-associated pneumonias in the groups of patients at high risk for nosocomial infections substantially (by more than twice. Conclusion. The findings have led to the conclusion that the extended package of preventive measures is effective in preventing respiratory infections in ICU patients. Of special note is the proper prevention of upper airway contamination with pathogenic microorganisms, by employing the closed aspiration systems with a built-in antibacterial filter. The routine use of high-tech consumables in the intensive care of surgical patients causes a considerable decrease in the incidence of nosocomial pneumonia, ventilator-associated pneumonia, and purulent tracheobronchitis and a reduction in the number of microbiological studies. Key words: ventilator-associated pneumonia, prevention of nosocomial infections, closed aspiration system.

  1. [Respiratory handicap. Recognition, evaluation and social benefits].

    Marsac, J; Pujet, J C

    1983-01-01

    The medico-social aspects of respiratory handicap pose some perplexing problems, notably in their recognition, rigorous evaluation and in the granting of social security benefits. The clinical and respiratory function data should be standardised and classified according to type and significance of respiratory disease and also according to the degree of co-operation and understanding of the patient. The respiratory handicap should be evaluated after considering the functional disability engendered by the disorder and their socio-professional repercussions. The abnormality in the lungs should be measured by resting tests; the degree of disability by exercise studies; the socio-professional handicap by ergonometric tests to assess the scale of the demands and requirements of family and social and professional life, indeed the cultural and economic style of the individual concerned. Such combined studies would enable recognition of severe chronic respiratory handicap leading to decisions for exemption certificates, such as cases of severe respiratory failure in patients requiring supplementary treatment for oxygen therapy or assisted ventilation. The benefits and grants offered to those with respiratory handicaps would involve a number of rights relating to: care, work, costs of replacement of workers in the event of prolonged sick leave or the benefits of an invalidity pension. There will be other allowances such as invalidity cards, lodging special studies and other rights particularly relating to lodging and special equipment. The present scale is difficult to use both because of its lack of specificity and its ill-chosen terminology. For better balance between the handicap and the benefits offered, a common and more flexible system, with a printed table should be at hand for the doctor to use for certain decisions: long term illness, period of invalidity or early retirement because of medical incapacity. Within each table a sub-section should exist to allow for

  2. Westinghouse Small Modular Reactor nuclear steam supply system design

    Memmott, M. J.; Harkness, A. W.; Van Wyk, J. [Westinghouse Electric Company LLC, 600 Cranberry Woods Drive, Cranberry Twp. PA 16066 (United States)

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the first in a series of four papers which describe the design and functionality of the Westinghouse SMR. Also described in this series are the key drivers influencing the design of the Westinghouse SMR and the unique passive safety features of the Westinghouse SMR. Several critical motivators contributed to the development and integration of the Westinghouse SMR design. These design driving motivators dictated the final configuration of the Westinghouse SMR to varying degrees, depending on the specific features under consideration. These design drivers include safety, economics, AP1000{sup R} reactor expertise and experience, research and development requirements, functionality of systems and components, size of the systems and vessels, simplicity of design, and licensing requirements. The Westinghouse SMR NSSS consists of an integral reactor vessel within a compact containment vessel. The core is located in the bottom of the reactor vessel and is composed of 89 modified Westinghouse 17x17 Robust Fuel Assemblies (RFA). These modified fuel assemblies have an active core length of only 2.4 m (8 ft) long, and the entirety of the core is encompassed by a radial reflector. The Westinghouse SMR core operates on a 24 month fuel cycle. The reactor vessel is approximately 24.4 m (80 ft) long and 3.7 m (12 ft) in diameter in order to facilitate standard rail shipping to the site. The reactor vessel houses hot and cold leg channels to facilitate coolant flow, control rod drive mechanisms (CRDM), instrumentation and cabling, an intermediate flange to separate flow and instrumentation and facilitate simpler refueling, a pressurizer, a straight tube, recirculating steam

  3. Gene editing as a promising approach for respiratory diseases.

    Bai, Yichun; Liu, Yang; Su, Zhenlei; Ma, Yana; Ren, Chonghua; Zhao, Runzhen; Ji, Hong-Long

    2018-03-01

    Respiratory diseases, which are leading causes of mortality and morbidity in the world, are dysfunctions of the nasopharynx, the trachea, the bronchus, the lung and the pleural cavity. Symptoms of chronic respiratory diseases, such as cough, sneezing and difficulty breathing, may seriously affect the productivity, sleep quality and physical and mental well-being of patients, and patients with acute respiratory diseases may have difficulty breathing, anoxia and even life-threatening respiratory failure. Respiratory diseases are generally heterogeneous, with multifaceted causes including smoking, ageing, air pollution, infection and gene mutations. Clinically, a single pulmonary disease can exhibit more than one phenotype or coexist with multiple organ disorders. To correct abnormal function or repair injured respiratory tissues, one of the most promising techniques is to correct mutated genes by gene editing, as some gene mutations have been clearly demonstrated to be associated with genetic or heterogeneous respiratory diseases. Zinc finger nucleases (ZFN), transcription activator-like effector nucleases (TALEN) and clustered regulatory interspaced short palindromic repeats/CRISPR-associated protein 9 (CRISPR/Cas9) systems are three innovative gene editing technologies developed recently. In this short review, we have summarised the structure and operating principles of the ZFNs, TALENs and CRISPR/Cas9 systems and their preclinical and clinical applications in respiratory diseases. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Patient training in respiratory-gated radiotherapy

    Kini, Vijay R.; Vedam, Subrahmanya S.; Keall, Paul J.; Patil, Sumukh; Chen, Clayton; Mohan, Radhe

    2003-01-01

    Respiratory gating is used to counter the effects of organ motion during radiotherapy for chest tumors. The effects of variations in patient breathing patterns during a single treatment and from day to day are unknown. We evaluated the feasibility of using patient training tools and their effect on the breathing cycle regularity and reproducibility during respiratory-gated radiotherapy. To monitor respiratory patterns, we used a component of a commercially available respiratory-gated radiotherapy system (Real Time Position Management (RPM) System, Varian Oncology Systems, Palo Alto, CA 94304). This passive marker video tracking system consists of reflective markers placed on the patient's chest or abdomen, which are detected by a wall-mounted video camera. Software installed on a PC interfaced to this camera detects the marker motion digitally and records it. The marker position as a function of time serves as the motion signal that may be used to trigger imaging or treatment. The training tools used were audio prompting and visual feedback, with free breathing as a control. The audio prompting method used instructions to 'breathe in' or 'breathe out' at periodic intervals deduced from patients' own breathing patterns. In the visual feedback method, patients were shown a real-time trace of their abdominal wall motion due to breathing. Using this, they were asked to maintain a constant amplitude of motion. Motion traces of the abdominal wall were recorded for each patient for various maneuvers. Free breathing showed a variable amplitude and frequency. Audio prompting resulted in a reproducible frequency; however, the variability and the magnitude of amplitude increased. Visual feedback gave a better control over the amplitude but showed minor variations in frequency. We concluded that training improves the reproducibility of amplitude and frequency of patient breathing cycles. This may increase the accuracy of respiratory-gated radiation therapy

  5. On the phosphorylase activity of GH3 enzymes: A β-N-acetylglucosaminidase from Herbaspirillum seropedicae SmR1 and a glucosidase from Saccharopolyspora erythraea.

    Ducatti, Diogo R B; Carroll, Madison A; Jakeman, David L

    2016-11-29

    A phosphorolytic activity has been reported for beta-N-acetylglucosaminidases from glycoside hydrolase family 3 (GH3) giving an interesting explanation for an unusual histidine as catalytic acid/base residue and suggesting that members from this family may be phosphorylases [J. Biol. Chem. 2015, 290, 4887]. Here, we describe the characterization of Hsero1941, a GH3 beta-N-acetylglucosaminidase from the endophytic nitrogen-fixing bacterium Herbaspirillum seropedicae SmR1. The enzyme has significantly higher activity against pNP-beta-D-GlcNAcp (K m  = 0.24 mM, k cat  = 1.2 s -1 , k cat /K m  = 5.0 mM -1 s -1 ) than pNP-beta-D-Glcp (K m  = 33 mM, k cat  = 3.3 × 10 -3 s -1 , k cat /K m  = 9 × 10 -4  mM -1 s -1 ). The presence of phosphate failed to significantly modify the kinetic parameters of the reaction. The enzyme showed a broad aglycone site specificity, being able to hydrolyze sugar phosphates beta-D-GlcNAc 1P and beta-D-Glc 1P, albeit at a fraction of the rate of hydrolysis of aryl glycosides. GH3 beta-glucosidase EryBI, that does not have a histidine as the general acid/base residue, also hydrolyzed beta-D-Glc 1P, at comparable rates to Hsero1941. These data indicate that Hsero1941 functions primarily as a hydrolase and that phosphorolytic activity is likely adventitious. The prevalence of histidine as a general acid/base residue is not predictive, nor correlative, with GH3 beta-N-acetylglucosaminidases having phosphorolytic activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Comparison of Sensorimotor Rhythm (SMR and Beta Training on Selective Attention and Symptoms in Children with Attention Deficit/Hyperactivity Disorder (ADHD: A Trend Report

    Mohammad Reza Mohammadi

    2015-11-01

    Full Text Available  Objective: The aim of this study was to assess and compare the effect of two neurofeedback protocols (SMR/theta and beta/theta on ADHD symptoms, selective attention and EEG (electroencephalogram parameters in children with ADHD.  Method:The sample consisted of 16 children (9-15 year old: 13 boys; 3 girls with ADHD-combined type (ADHD-C. All of children used methylphenidate (MPH during the study. The neurofeedback training consisted of two phases of 15 sessions, each lasting 45 minutes. In the first phase, participants were trained to enhance sensorimotor rhythm (12-15 Hz and reduce theta activity (4-8 Hz at C4 and in the second phase; they had to increase beta (15-18 Hz and reduce theta activity at C3. Assessments consisted of d2 attention endurance test, ADHD rating scale (parent form at three time periods: before, middle and the end of the training. EEG signals were recorded just before and after the training . Result:Based on parents’ reports, inattention after beta/theta training, and hyperactivity/impulsivity were improved after the end of the training. All subscales of d2 test were improved except for the difference between maximum and minimum responses. However, EEG analysis showed no significant differences . Conclusion:Neurofeedback in conjunction with Methylphenidate may cause further improvement in ADHD symptoms reported by parents and selective attention without long-term impact on EEG patterns. However, determining the exact relationship between EEG parameters, neurofeedback protocols and ADHD symptoms remain unclear.

  7. Critical Thinking in Respiratory Therapy Students: Comparing Baccalaureate and Associate Degree Students

    Clark, Myava C.

    2012-01-01

    Respiratory care is an allied health discipline that specializes in cardiopulmonary function and health. Respiratory therapists apply scientific principles to prevent, identify, and treat acute and chronic dysfunction of the cardiopulmonary system. Respiratory care specifically focuses on the assessment, treatment, management, control, diagnostic…

  8. Didactic tools for understanding respiratory physiology

    Kehoe, P Donnelly; Bratovich, C; Perrone, Ms; Castells, L Mendez

    2007-01-01

    The challenges in Bioengineering are not only the application of engineering knowledge to the measurement of physiological variables, but also the simulation of biological systems. Experience has shown that the physiology of the respiratory system involves a set of concepts that cannot be effectively taught without the help of a group of didactic tools that contribute to the measurement of characteristic specific variables and to the simulation of the system itself. This article describes a series of tools designed to optimize the teaching of the respiratory system, including the use of spirometers and software developed entirely by undergraduate Bioengineering students from Universidad Nacional de Entre Rios (UNER). The impact these resources have caused on the understanding of the topic and how each of them has facilitated the interpretation of the concepts by the students is also discussed

  9. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Allmendinger, Thomas [Siemens Healthcare, GmbH, Computed Tomography Division, Forchheim (Germany)

    2017-09-15

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.

  10. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    Goo, Hyun Woo; Allmendinger, Thomas

    2017-01-01

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children

  11. Submersion and acute respiratory failure

    Yu-Jang Su

    2014-01-01

    Conclusions: Submersion patients who are hypothermic on arrival of emergency department (ED are risky to respiratory failure and older, more hypothermic, longer hospital stay in suicidal submersion patients.

  12. Management of Postoperative Respiratory Failure.

    Mulligan, Michael S; Berfield, Kathleen S; Abbaszadeh, Ryan V

    2015-11-01

    Despite best efforts, postoperative complications such as postoperative respiratory failure may occur and prompt recognition of the process and management is required. Postoperative respiratory failure, such as postoperative pneumonia, postpneumonectomy pulmonary edema, acute respiratory distress-like syndromes, and pulmonary embolism, are associated with high morbidity and mortality. The causes of these complications are multifactorial and depend on preoperative, intraoperative, and postoperative factors, some of which are modifiable. The article identifies some of the risk factors, causes, and treatment strategies for successful management of the patient with postoperative respiratory failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Respiratory mass spectrometer

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  14. The respiratory mass spectrometer

    Mostert, J.W.

    1983-01-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M 2 body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O 2 consumption of less than 50 ml O 2 /min/M 2 ) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery

  15. Acute Respiratory Distress Syndrome

    Carmen Sílvia Valente Barbas

    2012-01-01

    Full Text Available This paper, based on relevant literature articles and the authors' clinical experience, presents a goal-oriented respiratory management for critically ill patients with acute respiratory distress syndrome (ARDS that can help improve clinicians' ability to care for these patients. Early recognition of ARDS modified risk factors and avoidance of aggravating factors during hospital stay such as nonprotective mechanical ventilation, multiple blood products transfusions, positive fluid balance, ventilator-associated pneumonia, and gastric aspiration can help decrease its incidence. An early extensive clinical, laboratory, and imaging evaluation of “at risk patients” allows a correct diagnosis of ARDS, assessment of comorbidities, and calculation of prognostic indices, so that a careful treatment can be planned. Rapid administration of antibiotics and resuscitative measures in case of sepsis and septic shock associated with protective ventilatory strategies and early short-term paralysis associated with differential ventilatory techniques (recruitment maneuvers with adequate positive end-expiratory pressure titration, prone position, and new extracorporeal membrane oxygenation techniques in severe ARDS can help improve its prognosis. Revaluation of ARDS patients on the third day of evolution (Sequential Organ Failure Assessment (SOFA, biomarkers and response to infection therapy allows changes in the initial treatment plans and can help decrease ARDS mortality.

  16. Respiratory symptoms of megaesophagus

    Fabio Di Stefano

    2013-03-01

    Full Text Available Megaesophagus as the end result of achalasia is the consequence of disordered peristalsis and the slow decompensation of the esophageal muscular layer. The main symptoms of achalasia are dysphagia, regurgitation, chest pain and weight loss, but respiratory symptoms, such as coughing, particularly when patients lie in a horizontal position, may also be common due to microaspiration. A 70-year old woman suffered from a nocturnal cough and shortness of breath with stridor. She reported difficulty in swallowing food over the past ten years, but had adapted by eating a semi-liquid diet. Chest X-ray showed right hemithorax patchy opacities projecting from the posterior mediastinum. Chest computed tomography scan showed a marked dilatation of the esophagus with abundant food residues. Endoscopy confirmed the diagnosis of megaesophagus due to esophageal achalasia, excluding other causes of obstruction, such as secondary esophagitis, polyps, leiomyoma or leiomyosarcoma. In the elderly population, swallowing difficulties due to esophageal achalasia are often underestimated and less troublesome than the respiratory symptoms that are caused by microaspiration. The diagnosis of esophageal achalasia, although uncommon, should be considered in patients with nocturnal chronic coughs and shortness of breath with stridor when concomitant swallowing difficulties are present.

  17. Acute respiratory distress syndrome

    Marco Confalonieri

    2017-04-01

    Full Text Available Since its first description, the acute respiratory distress syndrome (ARDS has been acknowledged to be a major clinical problem in respiratory medicine. From July 2015 to July 2016 almost 300 indexed articles were published on ARDS. This review summarises only eight of them as an arbitrary overview of clinical relevance: definition and epidemiology, risk factors, prevention and treatment. A strict application of definition criteria is crucial, but the diverse resource-setting scenarios foster geographic variability and contrasting outcome data. A large international multicentre prospective cohort study including 50 countries across five continents reported that ARDS is underdiagnosed, and there is potential for improvement in its management. Furthermore, epidemiological data from low-income countries suggest that a revision of the current definition of ARDS is needed in order to improve its recognition and global clinical outcome. In addition to the well-known risk-factors for ARDS, exposure to high ozone levels and low vitamin D plasma concentrations were found to be predisposing circumstances. Drug-based preventive strategies remain a major challenge, since two recent trials on aspirin and statins failed to reduce the incidence in at-risk patients. A new disease-modifying therapy is awaited: some recent studies promised to improve the prognosis of ARDS, but mortality and disabling complications are still high in survivors in intensive care.

  18. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance

    Korreman, Stine S.; Juhler-Nottrup, T