WorldWideScience

Sample records for respiratory protection program

  1. Acceptable respiratory protection program and LASL respirator research

    International Nuclear Information System (INIS)

    Skaggs, B.J.

    1979-01-01

    A short history is presented on the LASL Respiratory Protection Training Programs. Then a discussion is given on the major points of an acceptable respiratory protection program utilizing the points required by the Occupational, Safety, and Health Administration (OSHA) Regulation 29 CFR 1910.134. Contributions to respirator research are reviewed. Discussion is presented under the following section headings: program administration; respirator selection; respirator use; fitting and training; respirator maintenance; medical clearance and surveillance; special problems; program evaluation; and documentation

  2. 10 CFR 850.28 - Respiratory protection.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Respiratory protection. 850.28 Section 850.28 Energy... Respiratory protection. (a) The responsible employer must establish a respiratory protection program that complies with the respiratory protection program requirements of 29 CFR 1910.134, Respiratory Protection...

  3. Evaluation of Respiratory Protection Program in Petrochemical Industries: Application of Analytic Hierarchy Process

    Directory of Open Access Journals (Sweden)

    Hadi Kolahi

    2018-03-01

    Full Text Available Background: Respiratory protection equipment (RPE is the last resort to control exposure to workplace air pollutants. A comprehensive respiratory protection program (RPP ensures that RPE is selected, used, and cared properly. Therefore, RPP must be well integrated into the occupational health and safety requirements. In this study, we evaluated the implementation of RPP in Iranian petrochemical industries to identify the required solutions to improve the current status of respiratory protection. Methods: This cross-sectional study was conducted among 24 petrochemical industries in Iran. The survey instrument was a checklist extracted from the Occupational Safety and Health Administration respiratory protection standard. An index, Respiratory Protection Program Index (RPPI, was developed and weighted by analytic hierarchy process to determine the compliance rate (CR of provided respiratory protection measures with the RPP standard. Data analysis was performed using Excel 2010. Results: The most important element of RPP, according to experts, was respiratory hazard evaluation. The average value of RPPI in the petrochemical plants was 49 ± 15%. The highest and lowest of CR among RPP elements were RPE selection and medical evaluation, respectively. Conclusion: None of studied petrochemical industries implemented RPP completely. This can lead to employees' overexposure to hazardous workplace air contaminants. Increasing awareness of employees and employers through training is suggested by this study to improve such conditions. Keywords: analytic hierarchy process, petrochemical industries, respiratory protection program

  4. Evaluation of a model training program for respiratory-protection preparedness at local health departments.

    Science.gov (United States)

    Alfano-Sobsey, Edie; Kennedy, Bobby; Beck, Frank; Combs, Brian; Kady, Wendy; Ramsey, Steven; Stockweather, Allison; Service, Will

    2006-04-01

    Respiratory-protection programs have had limited application in local health departments and have mostly focused on protecting employees against exposure to tuberculosis (TB). The need to provide the public health workforce with effective respiratory protection has, however, been underscored by recent concerns about emerging infectious diseases, bioterrorism attacks, drug-resistant microbes, and environmental exposures to microbial allergens (as in recent hurricane flood waters). Furthermore, OSHA has revoked the TB standard traditionally followed by local health departments, replacing it with a more stringent regulation. The additional OSHA requirements may place increased burdens on health departments with limited resources and time. For these reasons, the North Carolina Office of Public Health Preparedness and Response and industrial hygienists of the Public Health Regional Surveillance Teams have developed a training program to facilitate implementation of respiratory protection programs at local health departments. To date, more than 1,400 North Carolina health department employees have been properly fit-tested for respirator use and have received training in all aspects of respiratory protection. This article gives an overview of the development and evaluation of the program. The training approach presented here can serve as a model that other health departments and organizations can use in implementing similar respiratory-protection programs.

  5. Perceived Competence and Comfort in Respiratory Protection

    Science.gov (United States)

    Burgel, Barbara J.; Novak, Debra; Burns, Candace M.; Byrd, Annette; Carpenter, Holly; Gruden, MaryAnn; Lachat, Ann; Taormina, Deborah

    2015-01-01

    In response to the Institute of Medicine (2011) report Occupational Health Nurses and Respiratory Protection: Improving Education and Training, a nationwide survey was conducted in May 2012 to assess occupational health nurses’ educational preparation, roles, responsibilities, and training needs in respiratory protection. More than 2,000 occupational health nurses responded; 83% perceived themselves as competent, proficient, or expert in respiratory protection, reporting moderate comfort with 12 respiratory program elements. If occupational health nurses had primary responsibility for the respiratory protection program, they were more likely to perceive higher competence and more comfort in respiratory protection, after controlling for occupational health nursing experience, highest education, occupational health nursing certification, industry sector, Association of Occupational Health Professionals in Healthcare membership, taking a National Institute for Occupational Safety and Health spirometry course in the prior 5 years, and perceiving a positive safety culture at work. These survey results document high perceived competence and comfort in respiratory protection. These findings support the development of targeted educational programs and interprofessional competencies for respiratory protection. PMID:23429638

  6. Guide to industrial respiratory protection

    International Nuclear Information System (INIS)

    Pritchard, J.A.

    1977-03-01

    The Occupational Safety and Health Act of 1970 has increased the emphasis on proper selection and use of respirators in situations where engineering controls are not feasible or are being implemented. Although a great deal of information on respiratory protection has been published, most of it is more technical than necessary for the average user faced with day-to-day problems of respiratory protection in industrial environments. This Guide is to provide the industrial user a single reference source containing enough information for establishing and maintaining a respirator program that meets the OSHA requirements outlined in 29 CFR Part 1910.134. It includes chapters on respirator selection, use, maintenance, and inspection, a complete description of all types of respirators and their advantages and limitations, and chapters on respirator fitting and wearer training, respiratory physiology, respiratory hazards, and physiological and psychological limitations. Also included are samples of the decision logic used in respirator selection, guidance on setting up an adequate respirator program through formulation of written standard operating procedures, and discussion of the meaning of the approved respirator

  7. The American Association of Occupational Health Nurses' Respiratory Protection Education Program and Resources Webkit for Occupational Health Professionals.

    Science.gov (United States)

    Pompeii, Lisa; Byrd, Annette; Delclos, George L; Conway, Sadie H

    2016-12-01

    Organizations are required to adhere to the Occupational Safety and Health Administration's (OSHA) Respiratory Protection Standard (29 CFR 1910.134) if they have workers that wear a respirator on the job. They must also have an employee "suitably trained" to administer their program. The National Institute for Occupational Safety and Health and its National Personal Protective Technology Laboratory have worked to champion the occupational health nurse in this role by collaborating with the American Association of Occupational Health Nurses to develop free, online respiratory protection training and resources (RPP Webkit). This article describes the development, content, and success of this training. To date, 724 participants have completed the training, 32.6% of whom lead their organization's respiratory protection program, 15.3% who indicated they will lead a program in the near future, and 52% who did not lead a program, but indicated that the training was relevant to their work. The majority "strongly agreed" the training was applicable to their work and it enhanced their professional expertise. © 2016 The Author(s).

  8. Manual of respiratory protection against airborne radioactive materials

    International Nuclear Information System (INIS)

    Caplin, J.L.; Held, B.J.; Catlin, R.J.

    1976-10-01

    The manual supplements Regulatory Guide 8.15, ''Acceptable Programs for Respiratory Protection''. It provides broad guidance for the planned use of respirators to protect individuals from airborne radioactive materials that might be encountered during certain operations. The guidance is intended for use by management in establishing and supervising programs and by operating personnel in implementing programs. Guidance is primarily directed to the use of respirators to prevent the inhalation of airborne radioactive materials. Protection against other modes of intake (e.g., absorption, swallowing, wound injection) is, in general, not covered nor is the use of protective equipment for head, eye, or skin protection

  9. 33 CFR 142.39 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Respiratory protection. 142.39... Respiratory protection. (a) Personnel in an atmosphere specified under ANSI Z88.2, requiring the use of respiratory protection equipment shall wear the type of respiratory protection equipment specified in ANSI Z88...

  10. Manual of respiratory protection against airborne radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Caplin, J.L.; Held, B.J.; Catlin, R.J.

    1976-10-01

    The manual supplements Regulatory Guide 8.15, ''Acceptable Programs for Respiratory Protection''. It provides broad guidance for the planned use of respirators to protect individuals from airborne radioactive materials that might be encountered during certain operations. The guidance is intended for use by management in establishing and supervising programs and by operating personnel in implementing programs. Guidance is primarily directed to the use of respirators to prevent the inhalation of airborne radioactive materials. Protection against other modes of intake (e.g., absorption, swallowing, wound injection) is, in general, not covered nor is the use of protective equipment for head, eye, or skin protection.

  11. 46 CFR 154.1405 - Respiratory protection.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Respiratory protection. 154.1405 Section 154.1405... Equipment § 154.1405 Respiratory protection. When Table 4 references this section, a vessel carrying the listed cargo must have: (a) Respiratory protection equipment for each person on board that protects the...

  12. 29 CFR 1915.154 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Respiratory protection. 1915.154 Section 1915.154 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... (PPE) § 1915.154 Respiratory protection. Respiratory protection for shipyard employment is covered by...

  13. 33 CFR 127.1209 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Respiratory protection. 127.1209... Waterfront Facilities Handling Liquefied Hazardous Gas Equipment § 127.1209 Respiratory protection. Each waterfront facility handling LHG must provide equipment for respiratory protection for each employee of the...

  14. Respiratory Protection Program. Programmatic description

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, J.M.; Porter, W.E.

    1986-03-01

    The ORNL Respirator Program is designed to provide employees with devices which afford maximum protection with minimum inconvenience and discomfort. Teamwork is essential since a comprehensive program involves the Medical Department, the Industrial Hygiene Department, Radiation and Safety Surveys, the Operations Division, Quality Assurance and Inspection, and the Fire Department. The purpose of this manual is to describe in detail the ORNL Respirator Program. Included are discussions of the following elements: quality assurance, selection, fit-testing, maintenance and issue, certified breathing air for self-contained breathing apparatus, inspection, program surveillance, available devices, and standard operating procedures. As program modifications develop and improvements are made, periodic revisions may be necessary. The Industrial Hygiene Department will perform this task on an ''as required'' basis.

  15. 46 CFR 197.550 - Respiratory protection.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Respiratory protection. 197.550 Section 197.550 Shipping... GENERAL PROVISIONS Benzene § 197.550 Respiratory protection. (a) General. When the use of respirators in... section that is appropriate for the exposure. Table 197.550(b)—Respiratory Protection for Benzene Airborne...

  16. 29 CFR 1917.92 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Respiratory protection. 1917.92 Section 1917.92 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) MARINE TERMINALS Personal Protection § 1917.92 Respiratory protection. (See § 1917.1(a)(2)(x...

  17. 29 CFR 1926.103 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Respiratory protection. 1926.103 Section 1926.103 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... § 1926.103 Respiratory protection. Note: The requirements applicable to construction work under this...

  18. 29 CFR 1918.102 - Respiratory protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Respiratory protection. 1918.102 Section 1918.102 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Respiratory protection. (See § 1918.1(b)(8)). [65 FR 40946, June 30, 2000] ...

  19. Evaluation of protection factor of respiratory protective equipment using indigenously developed protection factor test facility

    International Nuclear Information System (INIS)

    Patkulkar, D.S.; Ganesh, G.; Tripathi, R.M.

    2018-01-01

    Assigned protection factor (APF) is an indicator representing effectiveness of a respirator and it provides workplace level of respiratory protection for workers in providing protection against exposure to airborne contaminants Occupational Safety and Health Administration (OSHA) specifies 'Respirator APF' and 'Maximum Use Concentration' (MUC - a term derived using APF) shall be an integral part of Respirator Protection Standard. MUC establishes the maximum airborne concentration of a contaminant in which a respirator with a given APF may be used. The use of particulate respirators such as half face mask, full face mask and powered air purifying respirators is essential for radioactive jobs in nuclear facilities to prevent any intake of radionuclide. With this impetus, the Protection Factor Test Facility (PFTF) for testing and evaluation of respiratory protective equipment meeting relevant applicable standards was designed, fabricated and installed in Respiratory Protective Equipment Laboratory of Health Physics Division

  20. RCT: Module 2.07, Respiratory Protection, Course 8773

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-10

    Internal dosimetry controls require the use of engineering controls to prevent the internal deposition of radioactive and nonradiological contaminants. However, when engineering and administrative controls are not available or feasible, respiratory protection may be necessary. The radiation control technician (RCT) should know and apply the considerations used in determining the respiratory protection equipment that is most appropriate for the job. The inappropriate use of or the use of the wrong respiratory protection equipment may result in undesirable health effects. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  1. Employee guide to respiratory protection

    International Nuclear Information System (INIS)

    Wright, E.M.

    1982-01-01

    This employee guide discusses use of respiratory protective equipment for particulates, gases, vapors, supplied air, and self-contained breathing apparatus. It also covers equipment selection medical factors, fitting criteria; care; and employee responsibilities

  2. Respiratory protection from isocyanate exposure in the autobody repair and refinishing industry.

    Science.gov (United States)

    Liu, Youcheng; Stowe, Meredith H; Bello, Dhimiter; Woskie, Susan R; Sparer, Judy; Gore, Rebecca; Youngs, Fred; Cullen, Mark R; Redlich, Carrie A

    2006-05-01

    This study, part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), evaluated the effectiveness of respiratory protection against exposure to aliphatic polyisocyanates. A total of 36 shops were assessed for respiratory protection program completeness; 142 workers were measured for respirator fit factor (FF) using PortaCount Plus respirator fit tester. Twenty-two painters from 21 shops were sampled using NIOSH method 5525 to determine the workplace protection factor (WPF) of negative pressure, air-purifying half-facepiece respirators equipped with organic vapor cartridges and paint prefilters during spray-painting and priming activities. Only 11 shops (30%) had written respiratory protection programs. Eighty percent of all fit tested workers passed the test on the first try with FF >or= 100, and 92% passed the second test after respirator use training. Overall geometric mean (GM) FF was 1012 for all fit tested workers. Significant differences on pass rate (92% vs. 72%) and on FF (1990 vs. 736) were found between previously fit tested workers vs. nontested workers. Twenty-nine WPF samples were collected. The outside facepiece GM concentration of total isocyanate group (NCO) was 378.4 micro g NCO/m(3) with 96% concentrations exceeding the U.K. short-term exposure limit, 70 micro g NCO/m(3), but no in-facepiece concentrations exceeded the limit. The GM WPF of total NCO was 319 (GSD 4) and the 5th percentile was 54. WPF of total NCO was positively correlated with the duration of painting task. FF positively correlated with WPF when FF was 450. We conclude that negative pressure, air-purifying half-facepiece respirators equipped with organic vapor cartridges and paint prefilters provide effective protection against isocyanate exposure in spray and priming operations if workers are properly trained and fitted.

  3. Comparison of performance of three different types of respiratory protection devices.

    Science.gov (United States)

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    qualitative (Bitrex and saccharin) and quantitative (N95-Companion) fit testing were performed on the N95 filtering- and elastomeric-facepiece respirators. It was found that passing a fit test generally improves the protection afforded the wearer. Passing the Bitrex fit test resulted in 5th percentile SWPFs of 11.1 and 7.9 for elastomeric and filtering-facepiece respirators, respectively. After passing the saccharin tests, the elastomeric respirators provided a 5th percentile of 11.7, and the filtering-facepiece respirators provided a 5th percentile of 11.0. The 5th percentiles after passing the N95-Companion were 13.0 for the elastomeric respirators and 20.5 for the filtering-facepiece respirators. The data supports fit testing as an essential element of a complete respiratory protection program.

  4. LUDEP 1. 0, a personal computer program to implement the new ICRP respiratory tract model

    Energy Technology Data Exchange (ETDEWEB)

    Jarvis, N.S.; Birchall, A. (National Radiological Protection Board, Chilton (United Kingdom))

    1994-01-01

    The International Commission on Radiological Protection has recently approved a new model of the human respiratory tract. This model has been designed to represent realistically the deposition and biokinetic behaviour of inhaled radionuclides, and to calculate doses to the respiratory tract. In order to examine the practical application and radiological implications of the new model, a Personal Computer program has been developed. LUDEP 1.0 is a user-friendly program for the IBM-compatible PC which enables the user to calculate doses to the respiratory tract and to other organs. (author).

  5. Differences in Hospital Managers’, Unit Managers’, and Health Care Workers’ Perceptions of the Safety Climate for Respiratory Protection

    Science.gov (United States)

    Peterson, Kristina; Rogers, Bonnie M. E.; Brosseau, Lisa M.; Payne, Julianne; Cooney, Jennifer; Joe, Lauren; Novak, Debra

    2017-01-01

    This article compares hospital managers’ (HM), unit managers’ (UM), and health care workers’ (HCW) perceptions of respiratory protection safety climate in acute care hospitals. The article is based on survey responses from 215 HMs, 245 UMs, and 1,105 HCWs employed by 98 acute care hospitals in six states. Ten survey questions assessed five of the key dimensions of safety climate commonly identified in the literature: managerial commitment to safety, management feedback on safety procedures, coworkers’ safety norms, worker involvement, and worker safety training. Clinically and statistically significant differences were found across the three respondent types. HCWs had less positive perceptions of management commitment, worker involvement, and safety training aspects of safety climate than HMs and UMs. UMs had more positive perceptions of management’s supervision of HCWs’ respiratory protection practices. Implications for practice improvements indicate the need for frontline HCWs’ inclusion in efforts to reduce safety climate barriers and better support effective respiratory protection programs and daily health protection practices. PMID:27056750

  6. Differences in Hospital Managers', Unit Managers', and Health Care Workers' Perceptions of the Safety Climate for Respiratory Protection.

    Science.gov (United States)

    Peterson, Kristina; Rogers, Bonnie M E; Brosseau, Lisa M; Payne, Julianne; Cooney, Jennifer; Joe, Lauren; Novak, Debra

    2016-07-01

    This article compares hospital managers' (HM), unit managers' (UM), and health care workers' (HCW) perceptions of respiratory protection safety climate in acute care hospitals. The article is based on survey responses from 215 HMs, 245 UMs, and 1,105 HCWs employed by 98 acute care hospitals in six states. Ten survey questions assessed five of the key dimensions of safety climate commonly identified in the literature: managerial commitment to safety, management feedback on safety procedures, coworkers' safety norms, worker involvement, and worker safety training. Clinically and statistically significant differences were found across the three respondent types. HCWs had less positive perceptions of management commitment, worker involvement, and safety training aspects of safety climate than HMs and UMs. UMs had more positive perceptions of management's supervision of HCWs' respiratory protection practices. Implications for practice improvements indicate the need for frontline HCWs' inclusion in efforts to reduce safety climate barriers and better support effective respiratory protection programs and daily health protection practices. © 2016 The Author(s).

  7. Respiratory protection standard: comments on OSHA's proposed revision.

    Science.gov (United States)

    Decker, M D

    1995-06-01

    On November 15, 1994, the Occupational Safety and Health Administration (OSHA) published in the Federal Register (59:58884-58956) the draft of a proposed revision of the Respiratory Protection Standard. One of OSHA's oldest standards, the Respiratory Protection Standard defines the conduct of the employer (eg, hospital) with respect to respirator training, fit testing, medical examinations, use, storage, and so on. The proposed revision appears to have been drafted with no consideration for its effect on healthcare workers or the healthcare industry. SHEA has prepared the following comments to OSHA, which have been submitted to the docket and will be presented at public hearings later this month.

  8. Knowledge, perceptions and practices of healthcare workers regarding the use of respiratory protection equipment at Iran hospitals.

    Science.gov (United States)

    Honarbakhsh, Marzieh; Jahangiri, Mehdi; Ghaem, Haleh

    2018-01-01

    Using appropriate respiratory protection equipment (RPE) is very important to protect healthcare workers (HCWs) against respiratory hazards. The aim of this study was to identify the level of knowledge, perceptions and practices of HCWs on using RPE. This cross-sectional study was conducted with 284 employees of educational hospitals affiliated to Shiraz University of Medical Sciences. The study's instrument was a self-made questionnaire that comprised four components: demographic inquiries and questions designed to assess the knowledge, perceptions and practice of HCWs regarding RPE. Collected data were analysed using SPSS software version 21. Average scores of knowledge, perceptions and practice of HCWs on using RPE were 66.50% ± 11.93%, 80.32% ± 10.05% and 70.12% ± 20.51%, respectively. A significant association was observed between knowledge and age, job experience, history of using respirator, marital status and risk of respiratory hazards in the workplace and perceptions with age and education and practice with education. Studied HCWs had positive perceptions and moderate level of knowledge and practice about the use of RPE. Full implementation of respiratory protection program in the hospitals would be helpful to improve the knowledge, perceptions and practices of HCWs regarding RPE.

  9. Radiological respiratory protection in Angra-1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Amaral, Marcos A. do

    1996-01-01

    The present paper has the purpose to describe the actual situation of the Radiological respiratory Protection in Angra I Nuclear Power Plant, the difficulties found and the goals to achieve, in order of the radiological protection excellence. (author)

  10. 76 FR 13668 - Respiratory Protection Standard; Extension of the Office of Management and Budget's (OMB...

    Science.gov (United States)

    2011-03-14

    ...] Respiratory Protection Standard; Extension of the Office of Management and Budget's (OMB) Approval of... proposal to extend OMB approval of the information collection requirements specified by the Respiratory... Respiratory Protection Standard (29 CFR 1910.134; hereafter, ``the [[Page 13669

  11. Intraoperative protective mechanical ventilation and risk of postoperative respiratory complications: hospital based registry study.

    Science.gov (United States)

    Ladha, Karim; Vidal Melo, Marcos F; McLean, Duncan J; Wanderer, Jonathan P; Grabitz, Stephanie D; Kurth, Tobias; Eikermann, Matthias

    2015-07-14

    To evaluate the effects of intraoperative protective ventilation on major postoperative respiratory complications and to define safe intraoperative mechanical ventilator settings that do not translate into an increased risk of postoperative respiratory complications. Hospital based registry study. Academic tertiary care hospital and two affiliated community hospitals in Massachusetts, United States. 69,265 consecutively enrolled patients over the age of 18 who underwent a non-cardiac surgical procedure between January 2007 and August 2014 and required general anesthesia with endotracheal intubation. Protective ventilation, defined as a median positive end expiratory pressure (PEEP) of 5 cmH2O or more, a median tidal volume of less than 10 mL/kg of predicted body weight, and a median plateau pressure of less than 30 cmH2O. Composite outcome of major respiratory complications, including pulmonary edema, respiratory failure, pneumonia, and re-intubation. Of the 69,265 enrolled patients 34,800 (50.2%) received protective ventilation and 34,465 (49.8%) received non-protective ventilation intraoperatively. Protective ventilation was associated with a decreased risk of postoperative respiratory complications in multivariable regression (adjusted odds ratio 0.90, 95% confidence interval 0.82 to 0.98, P=0.013). The results were similar in the propensity score matched cohort (odds ratio 0.89, 95% confidence interval 0.83 to 0.97, P=0.004). A PEEP of 5 cmH2O and median plateau pressures of 16 cmH2O or less were associated with the lowest risk of postoperative respiratory complications. Intraoperative protective ventilation was associated with a decreased risk of postoperative respiratory complications. A PEEP of 5 cmH2O and a plateau pressure of 16 cmH2O or less were identified as protective mechanical ventilator settings. These findings suggest that protective thresholds differ for intraoperative ventilation in patients with normal lungs compared with those used for patients

  12. Field selection of chemical protective clothing and respiratory protection

    International Nuclear Information System (INIS)

    Pinette, S.; Dodgen, C.; Morley, M.

    1991-01-01

    Safety professionals who must choose appropriate personal protective equipment for hazardous substance response or hazardous waste sites require useable information about the effectiveness of the various products available. Each hazardous waste operation involves a unique combination of chemical hazards requiring a unique combination of protective apparel. A chemical protective suit or respirator must be chosen for each site and each operation on the site. No single protective suit is effective against all chemical hazards. No single respirator is the best choice in every situation. Various sources of information on the effectiveness of protective clothing products will be discussed. Site-specific permeation testing of the proposed protective clothing options will also be discussed. It is both possible and practical to obtain specific information about the degree of protection afforded by a particular suit against a particular chemical mixture. It is also important to know how long the suit will last. Choosing adequate respiratory protection is a complex process. Respirator cartridge performance depends on various environmental factors as well as upon the combination and concentration of chemicals in the air. Once characterization of the air at a site has been accomplished, it may be appropriate to select an alternative to airline respirators and SCBAs. Respirator cartridges can be tested against specific chemical mixtures using worse case environmental factors. The results can be used to predict both the effectiveness and duration of protection afforded by respirator cartridges which can reduce costs and worker fatigue

  13. Control and prevention of healthcare-associated tuberculosis: the role of respiratory isolation and personal respiratory protection.

    Science.gov (United States)

    Humphreys, H

    2007-05-01

    Although the prevalence of tuberculosis continues to decline in most developed countries, the risk of healthcare-associated tuberculosis, remains for patients or healthcare staff. Outbreaks of healthcare-associated tuberculosis are usually associated with delays in diagnosis and treatment, or the care of patients in sub-optimal facilities. The control and prevention of tuberculosis in hospitals is best achieved by three approaches, namely administrative (early investigation diagnosis, etc.), engineering (physical facilities e.g. ventilated isolation rooms) and personal respiratory protection (face sealing masks which are filtered). Recent guidelines on the prevention of tuberculosis in healthcare facilities from Europe and the USA have many common themes. In the UK, however, negative pressure isolation rooms are recommended only for patients with suspected multi-drug resistant TB and personal respiratory protection, i.e. filtered masks, are not considered necessary unless multi-drug resistant TB is suspected, or where aerosol-generating procedures are likely. In the US, the standard of care for patients with infectious tuberculosis is a negative pressure ventilated room and the use of personal respiratory protection for all healthcare workers entering the room of a patient with suspected or confirmed tuberculosis. The absence of clinical trials in this area precludes dogmatic recommendations. Nonetheless, observational studies and mathematical modelling suggest that all measures are required for effective prevention. Even when policies and facilities are optimal, there is a need to regularly review and audit these as sometimes compliance is less than optimal. The differences in recommendations may reflect the variations in epidemiology and the greater use of BCG vaccination in the UK compared with the United States. There is a strong argument for advising ventilated facilities and personal respiratory protection for the care of all patients with tuberculosis, as

  14. Intranasal DNA Vaccine for Protection against Respiratory Infectious Diseases: The Delivery Perspectives

    Directory of Open Access Journals (Sweden)

    Yingying Xu

    2014-07-01

    Full Text Available Intranasal delivery of DNA vaccines has become a popular research area recently. It offers some distinguished advantages over parenteral and other routes of vaccine administration. Nasal mucosa as site of vaccine administration can stimulate respiratory mucosal immunity by interacting with the nasopharyngeal-associated lymphoid tissues (NALT. Different kinds of DNA vaccines are investigated to provide protection against respiratory infectious diseases including tuberculosis, coronavirus, influenza and respiratory syncytial virus (RSV etc. DNA vaccines have several attractive development potential, such as producing cross-protection towards different virus subtypes, enabling the possibility of mass manufacture in a relatively short time and a better safety profile. The biggest obstacle to DNA vaccines is low immunogenicity. One of the approaches to enhance the efficacy of DNA vaccine is to improve DNA delivery efficiency. This review provides insight on the development of intranasal DNA vaccine for respiratory infections, with special attention paid to the strategies to improve the delivery of DNA vaccines using non-viral delivery agents.

  15. Nasally administered Lactobacillus rhamnosus strains differentially modulate respiratory antiviral immune responses and induce protection against respiratory syncytial virus infection.

    Science.gov (United States)

    Tomosada, Yohsuke; Chiba, Eriko; Zelaya, Hortensia; Takahashi, Takuya; Tsukida, Kohichiro; Kitazawa, Haruki; Alvarez, Susana; Villena, Julio

    2013-08-15

    Some studies have shown that nasally administered immunobiotics had the potential to improve the outcome of influenza virus infection. However, the capacity of immunobiotics to improve protection against respiratory syncytial virus (RSV) infection was not investigated before. The aims of this study were: a) to evaluate whether the nasal administration of Lactobacillus rhamnosus CRL1505 (Lr05) and L. rhamnosus CRL1506 (Lr06) are able to improve respiratory antiviral defenses and beneficially modulate the immune response triggered by TLR3/RIG-I activation; b) to investigate whether viability of Lr05 or Lr06 is indispensable to modulate respiratory immunity and; c) to evaluate the capacity of Lr05 and Lr06 to improve the resistance of infant mice against RSV infection. Nasally administered Lr05 and Lr06 differentially modulated the TLR3/RIG-I-triggered antiviral respiratory immune response. Lr06 administration significantly modulated the production of IFN-α, IFN-β and IL-6 in the response to poly(I:C) challenge, while nasal priming with Lr05 was more effective to improve levels of IFN-γ and IL-10. Both viable Lr05 and Lr06 strains increased the resistance of infant mice to RSV infection while only heat-killed Lr05 showed a protective effect similar to those observed with viable strains. The present work demonstrated that nasal administration of immunobiotics is able to beneficially modulate the immune response triggered by TLR3/RIG-I activation in the respiratory tract and to increase the resistance of mice to the challenge with RSV. Comparative studies using two Lactobacillus rhamnosus strains of the same origin and with similar technological properties showed that each strain has an specific immunoregulatory effect in the respiratory tract and that they differentially modulate the immune response after poly(I:C) or RSV challenges, conferring different degree of protection and using distinct immune mechanisms. We also demonstrated in this work that it is possible

  16. Respiratory Protection Behavior and Respiratory Indices among Poultry House Workers on Small, Family-Owned Farms in North Carolina: A Pilot Project.

    Science.gov (United States)

    Kearney, Gregory D; Gallagher, Barbara; Shaw, Robert

    2016-01-01

    The aim of this pilot study was to evaluate respiratory behavior and respiratory indices of poultry workers on family-owned, poultry farms with 10 or less employees in North Carolina. A field study was conducted to collect data on participants (N = 24) using spirometry, fractional exhaled nitric oxide (Feno), and an interviewer-administered questionnaire. The majority of workers (76%) ranked respiratory protection as being important, yet 48% reported never or rarely wearing respiratory protection when working in dusty conditions. A large percent of workers reported eye (55%) and nasal (50%) irritation and dry cough (50%). On average, pulmonary lung function and Feno tests were normal among nonsmokers. In bivariate analysis, significant associations were identified between working 7 days on the farm (P = .01), with eye irritation, and working 5 or fewer years in poultry farming (P = .01). Poultry workers on family-owned farms spend a considerable amount of work time in poultry houses and report acute respiratory-related health symptoms. Administrative controls among small, family-owned poultry farms are necessary to improve and promote safety and health to its employees.

  17. MGR COMPLIANCE PROGRAM GUIDANCE PACKAGE FOR RADIATION PROTECTION EQUIPMENT, INSTRUMENTATION, AND FACILITIES

    International Nuclear Information System (INIS)

    2000-01-01

    This Compliance Program Guidance Package identifies the regulatory guidance and industry codes and standards addressing radiation protection equipment, instrumentation, and support facilities considered to be appropriate for radiation protection at the Monitored Geologic Repository (MGR). Included are considerations relevant to radiation monitoring instruments, calibration, contamination control and decontamination, respiratory protection equipment, and general radiation protection facilities. The scope of this Guidance Package does not include design guidance relevant to criticality monitoring, area radiation monitoring, effluent monitoring, and airborne radioactivity monitoring systems since they are considered to be the topics of specific design and construction requirements (i.e., ''fixed'' or ''built-in'' systems). This Guidance Package does not address radiation protection design issues; it addresses the selection and calibration of radiation monitoring instrumentation to the extent that the guidance is relevant to the operational radiation protection program. Radon and radon progeny monitoring instrumentation is not included in the Guidance Package since such naturally occurring radioactive materials do not fall within the NRC's jurisdiction at the MGR

  18. Protective roles of free avian respiratory macrophages in captive birds

    Directory of Open Access Journals (Sweden)

    Mbuvi P. Mutua

    Full Text Available In the mammalian lung, respiratory macrophages provide front line defense against invading pathogens and particulate matter. In birds, respiratory macrophages are known as free avian respiratory macrophages (FARM and a dearth of the cells in the avian lung has been purported to foreordain a weak first line of pulmonary defense, a condition associated with high mortality of domestic birds occasioned by respiratory inflictions. Avian pulmonary mechanisms including a three tiered aerodynamic filtration system, tight epithelial junctions and an efficient mucociliary escalator system have been known to supplement FARM protective roles. Current studies, however, report FARM to exhibit an exceptionally efficient phagocytic capacity and are effective in elimination of invading pathogens. In this review, we also report on effects of selective synthetic peroxisome proliferator activated receptor gamma (PPAR γ agonists on non phlogistic phagocytic properties in the FARM. To develop effective therapeutic interventions targeting FARM in treatment and management of respiratory disease conditions in the poultry, further studies are required to fully understand the role of FARM in innate and adaptive immune responses.

  19. Evaluation on the implementation of respiratory protection measures in old age homes

    Directory of Open Access Journals (Sweden)

    Lee DT

    2017-09-01

    Full Text Available Diana TF Lee,1 Doris Yu,1 Margaret Ip,2 Jennifer YM Tang3 1The Nethersole School of Nursing, The Chinese University of Hong Kong, 2Department of Microbiology, The Chinese University of Hong Kong, Prince of Wales Hospital, Sha Tin, 3Sau Po Centre on Ageing, The University of Hong Kong, Pok Fu Lam, Hong Kong Purpose: Old age homes (OAHs represent a vulnerable community for influenza outbreaks. Effective implementation of respiratory protection measures has been identified as an effective prevention measure to reduce mortality and morbidity caused by such outbreaks. Yet, relatively little is known about this aspect in these homes. This study evaluated the implementation of respiratory protection measures among infection control officers (ICOs and health care workers (HCWs in these homes in Hong Kong.Patients and methods: A territory-wide, cross-sectional survey was conducted in 87 OAHs. A total of 87 ICOs and 1,763 HCWs (including nurses, health workers, care workers, allied HCWs and assistants completed the questionnaires that evaluated the implementation at the organizational level and individual level, respectively. Generalized estimating equations with unstructured working correlation matrix were used to analyze the simultaneous influence of organizational and individual factors on the implementation.Results: At the organizational level, all homes had a policy on respiratory protection and implementation of such measures was generally adequate. Basic resources such as paper towels/hand dryers and equipment disinfectants, however, were rated as most inadequate by HCWs. Training opportunities were also identified as grossly inadequate. Only less than half of the ICOs and HCWs participated in training on infection control either at the initiation of employment or on a regular basis. Twenty-five percent of HCWs even indicated that they had never participated in any infection control training. At the individual level, hand hygiene, among other

  20. Consumption of unprocessed cow's milk protects infants from common respiratory infections

    NARCIS (Netherlands)

    Loss, G.; Depner, M.; Ulfman, L.H.; Neerven, van R.J.J.; Hose, A.J.; Genuneit, J.

    2015-01-01

    Background: Breast-feeding is protective against respiratory infections in early life. Given the co-evolutionary adaptations of humans and cattle, bovine milk might exert similar anti-infective effects in human infants. Objective: To study effects of consumption of raw and processed cow's milk on

  1. Non-specific Effect of Vaccines: Immediate Protection against Respiratory Syncytial Virus Infection by a Live Attenuated Influenza Vaccine

    Directory of Open Access Journals (Sweden)

    Young J. Lee

    2018-01-01

    Full Text Available The non-specific effects (NSEs of vaccines have been discussed for their potential long-term beneficial effects beyond direct protection against a specific pathogen. Cold-adapted, live attenuated influenza vaccine (CAIV induces local innate immune responses that provide a broad range of antiviral immunity. Herein, we examined whether X-31ca, a donor virus for CAIVs, provides non-specific cross-protection against respiratory syncytial virus (RSV. The degree of RSV replication was significantly reduced when X-31ca was administered before RSV infection without any RSV-specific antibody responses. The vaccination induced an immediate release of cytokines and infiltration of leukocytes into the respiratory tract, moderating the immune perturbation caused by RSV infection. The potency of protection against RSV challenge was significantly reduced in TLR3-/- TLR7-/- mice, confirming that the TLR3/7 signaling pathways are necessary for the observed immediate and short-term protection. The results suggest that CAIVs provide short-term, non-specific protection against genetically unrelated respiratory pathogens. The additional benefits of CAIVs in mitigating acute respiratory infections for which vaccines are not yet available need to be assessed in future studies.

  2. A brain-targeted ampakine compound protects against opioid-induced respiratory depression.

    Science.gov (United States)

    Dai, Wei; Xiao, Dian; Gao, Xiang; Zhou, Xin-Bo; Fang, Tong-Yu; Yong, Zheng; Su, Rui-Bin

    2017-08-15

    The use of opioid drugs for pain relief can induce life-threatening respiratory depression. Although naloxone effectively counteracts opioid-induced respiratory depression, it diminishes the efficacy of analgesia. Our studies indicate that ampakines, in particular, a brain-targeted compound XD-8-17C, are able to reverse respiratory depression without affecting analgesia at relatively low doses. Mice and rats were subcutaneously or intravenously injected with the opioid agonist TH-030418 to induce moderate or severe respiratory depression. XD-8-17C was intravenously administered before or after TH-030418. The effect of XD-8-17C on opioid-induced respiratory depression was evaluated in terms of the opioid-induced acute death rate, arterial blood gas analysis and pulmonary function tests. In addition, the hot-plate test was conducted to investigate whether XD-8-17C influenced opioid-induced analgesia. Pre-treatment with XD-8-17C significantly reduced opioid-induced acute death, and increased the median lethal dose of TH-030418 by 4.7-fold. Blood gas analysis and pulmonary function tests demonstrated that post-treatment with XD-8-17C alleviated respiratory depression, as indicated by restoration of arterial blood gas (pO 2 , sO 2 , cK + ) and lung function parameters (respiratory frequency, minute ventilation) to the normal range. The hot-plate test showed that XD-8-17C had no impact on the antinociceptive efficacy of morphine. The ability of XD-8-17C to reverse opioid-induced respiratory depression has the potential to increase the safety and convenience of opioid treatment. These findings contribute to the discovery of novel therapeutic agents that protect against opioid-induced respiratory depression without loss of analgesia. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Bovine respiratory syncytial virus ISCOMs - protection in the presence of maternal antibodies

    DEFF Research Database (Denmark)

    Hägglund, Sara; Hu, Ke-Fei; Larsen, Lars Erik

    2004-01-01

    The protection induced by immunostimulating complexes (ISCOMs) against bovine respiratory syncytial virus (BRSV) was evaluated and compared to that of a commercial inactivated vaccine (CV) in calves with BRSV-specific maternal antibodies. Following experimental challenge, controls (n = 4...

  4. Programming of respiratory health in childhood: influence of outdoor air pollution.

    Science.gov (United States)

    Wright, Rosalind J; Brunst, Kelly J

    2013-04-01

    This overview highlights recent experimental and epidemiological evidence for the programming effects of outdoor air pollution exposures during early development on lung function and chronic respiratory disorders, such as asthma and related allergic disorders. Air pollutants may impact anatomy and/or physiological functioning of the lung and interrelated systems. Programming effects may result from pollutant-induced shifts in a number of molecular, cellular, and physiological states and their interacting systems. Specific key regulatory systems susceptible to programming may influence lung development and vulnerability to respiratory diseases, including both central and peripheral components of neuroendocrine pathways and autonomic nervous system (ANS) functioning which, in turn, influence the immune system. Starting in utero, environmental factors, including air pollutants, may permanently organize these systems toward trajectories of enhanced pediatric (e.g., asthma, allergy) as well as adult disease risk (e.g., chronic obstructive pulmonary disease). Evidence supports a central role of oxidative stress in the toxic effects of air pollution. Additional research suggests xenobiotic metabolism and subcellular components, such as mitochondria are targets of ambient air pollution and play a role in asthma and allergy programming. Mechanisms operating at the level of the placenta are being elucidated. Epigenetic mechanisms may be at the roots of adaptive developmental programming. Optimal coordinated functioning of many complex processes and their networks of interaction are necessary for normal lung development and the maintenance of respiratory health. Outdoor air pollution may play an important role in early programming of respiratory health and is potentially amenable to intervention.

  5. Human respiratory tract model for radiological protection: A revision of the ICRP Dosimetric Model for the Respiratory System

    International Nuclear Information System (INIS)

    Bair, W.J.

    1989-01-01

    In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users

  6. Effect of health education based on BASNEF pattern on use of personal protective respiratory equipment in Ahvaz carbon block factory workers, 2009

    Directory of Open Access Journals (Sweden)

    M Solhi

    2012-11-01

    Full Text Available   Background and aims: Respiratory diseases due to work with 50 million annually incidence included one third of all occupational diseases and it is one of the main causes of absenteeism from work in workers. Some occupational diseases can be prevented with personal protective equipment. BASNEF model is one of the effective health education and safety training models for workers. The aim of this study was to determine the effect of educational intervention based on BASNEF pattern on increasing the use of personal protective respiratory equipment among carbon black factory workers , where many air pollutants such as carbon block exists. Methods: In this study the intervention curriculum based on BASNEF pattern administrated on 100 (experimental and control Ahvaz carbon block factory workers. Data were collected by questionnaires. The data were analyzed by Independent T, χ square and Pearson correlation co- efficient using SPSS version16.   Results : After the intervention, the mean scores of knowledge, attitude, intention, and enabling factors showed significant increase in experimental group in comparison of control group (p<0.00001. In addition, the mean score of subjective norms in experimental and control groups showed no significant differences. Conclusion: The educational program based on BASNEF pattern was effective in improving the use of respiratory personal protective equipment in Ahvaz carbon block factory workers 

  7. Work-Related Health Effects in Swine Building Workers After Respiratory Protection Use

    DEFF Research Database (Denmark)

    Bønløkke, Jakob Hjort; Veillette, Marc; Mériaux, Anne

    2012-01-01

    OBJECTIVE:To compare inflammation and lung function in swine workers after periods with and without respiratory protection during work. METHODS:Twenty-three workers were examined before and after two nonprotected work shifts. One shift was preceded by a period with diminished exposure by use...

  8. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  9. Emergency respiratory protection with common materials

    International Nuclear Information System (INIS)

    Cooper, D.W.; Hinds, W.C.; Price, J.M.

    1983-01-01

    Certain unexpected accidents, such as fires, explosions, chemical spills, or nuclear reactor malfunctions, can lead to the exposure of workers and the public to toxic gases, vapors, and aerosols. The efficacy of readily available materials, such as cotton fabric, toweling, and a single-use respirator, for providing emergency respiratory protection was evaluated by determining the filtration efficiency as a function of particle size over the range of 0.4 to 5 μm diameter and performance against a reactive water soluble (I 2 ) and unreactive vapor (CH 3 I). At a reasonable design face velocity (1.5 cm/s), the respirator mask used at double thickness could reduce particle concentrations a factor of 30 or more throughout the particle range tested, and a wetted towel four layers thick could provide a factor of five. Dry fabrics were ineffective in removing iodine vapor, but wetted sheeting or toweling reduced concentration by a factor of ten or more under design conditions, 1.5 cm/s face velocity and 50 Pa pressure drop (0.2 inches of water). The fabrics provided a statistically insignificant reduction in methyliodide. In practice, any leaks around the seal to the face would lessen the protection offered by such materials. The effectiveness factor approach proved useful in comparing filter performance under different conditions

  10. GROUNDWATER PROTECTION MANAGEMENT PROGRAM DESCRIPTION.

    Energy Technology Data Exchange (ETDEWEB)

    PAQUETTE,D.E.; BENNETT,D.B.; DORSCH,W.R.; GOODE,G.A.; LEE,R.J.; KLAUS,K.; HOWE,R.F.; GEIGER,K.

    2002-05-31

    THE DEPARTMENT OF ENERGY ORDER 5400.1, GENERAL ENVIRONMENTAL PROTECTION PROGRAM, REQUIRES THE DEVELOPMENT AND IMPLEMENTATION OF A GROUNDWATER PROTECTION PROGRAM. THE BNL GROUNDWATER PROTECTION MANAGEMENT PROGRAM DESCRIPTION PROVIDES AN OVERVIEW OF HOW THE LABORATORY ENSURES THAT PLANS FOR GROUNDWATER PROTECTION, MONITORING, AND RESTORATION ARE FULLY DEFINED, INTEGRATED, AND MANAGED IN A COST EFFECTIVE MANNER THAT IS CONSISTENT WITH FEDERAL, STATE, AND LOCAL REGULATIONS.

  11. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  12. Filtration of nanoparticles - Application to respiratory protecting devices

    International Nuclear Information System (INIS)

    Brochot, C.

    2012-01-01

    This study aims to determine how the respiratory protective devices (RPD), whose performances are qualified for particles above 100 nm, are effective for nanoparticles. Indeed, if the use of a collective filtration is inadequate, wearing a RPD is the last protection recommended. A literature review showed that no research concerned the effectiveness of half-masks for nanoparticles. The test bench ETNA has been sized and built to overcome these lacks. Two half masks were tested according to different configurations: constant flow rate and cyclic flow rate (average flow of 84 L /min), particle size (from 5 to 100 nm), positions of the mask (sealed, usual, or with calibrated leaks). The results show that, since the RPD contain high efficiency filter media (without charged fibers) for the most penetrating particle size (100 nm - 300 nm), the RPD is more efficient for nanoparticles. Furthermore, the results obtained in the presence of actual and calibrated leaks, highlighted the importance of face seal leakages in determining the performance of RPD. A model for calculating the protection factor was established based on the balance between the airflow through the filter and the leak. This model was validated using measurements obtained in the presence of calibrated leaks, and applied for the analysis of our results in usual position. (author)

  13. Groundwater protection management program plan

    International Nuclear Information System (INIS)

    1992-06-01

    US Department of Energy (DOE) Order 5400.1 requires the establishment of a groundwater protection management program to ensure compliance with DOE requirements and applicable Federal, state, and local laws and regulations. The Uranium Mill Tailings Remedial Action (UMTRA) Project Office has prepared a ''Groundwater Protection Management Program Plan'' (groundwater protection plan) of sufficient scope and detail to reflect the program's significance and address the seven activities required in DOE Order 5400.1, Chapter 3, for special program planning. The groundwater protection plan highlights the methods designed to preserve, protect, and monitor groundwater resources at UMTRA Project processing and disposal sites. The plan includes an overview of the remedial action status at the 24 designated processing sites and identifies project technical guidance documents and site-specific documents for the UMTRA groundwater protection management program. In addition, the groundwater protection plan addresses the general information required to develop a water resources protection strategy at the permanent disposal sites. Finally, the plan describes ongoing activities that are in various stages of development at UMTRA sites (long-term care at disposal sites and groundwater restoration at processing sites). This plan will be reviewed annually and updated every 3 years in accordance with DOE Order 5400.1

  14. Radiological respiratory protection in Angra-1 Nuclear Power Plant; Protecao respiratoria radiologica na Usina Nuclear de Angra

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Marcos A. do [Furnas Centrais Eletricas S.A., Angra dos Reis, RJ (Brazil). Central Nuclear de Angra I. Div. de Protecao Radiologica e Ambiental

    1996-07-01

    The present paper has the purpose to describe the actual situation of the Radiological respiratory Protection in Angra I Nuclear Power Plant, the difficulties found and the goals to achieve, in order of the radiological protection excellence. (author)

  15. Protection against avian metapneumovirus subtype C in turkeys immunized via the respiratory tract with inactivated virus.

    Science.gov (United States)

    Cha, Ra Mi; Khatri, Mahesh; Sharma, Jagdev M

    2011-01-10

    Avian metapneumovirus subtype C (aMPV/C) causes a severe upper respiratory tract (URT) infection in turkeys. Turkeys were inoculated oculonasally with inactivated aMPV/C adjuvanted with synthetic double-stranded RNA polyriboinosinic polyribocytidylic acid (Poly IC). Immunized turkeys had elevated numbers of mucosal IgA+ cells in the URT and increased levels of virus-specific IgG and IgA in the lachrymal fluid and IgG in the serum. After 7 or 21 days post immunization, turkeys were challenged oculonasally with pathogenic aMPV/C. Immunized groups were protected against respiratory lesions induced by the challenge virus. Further, the viral copy number of the challenge virus in the URT were significantly lower in the immunized turkeys than in the unimmunized turkeys (P<0.05). These results showed that inactivated aMPV/C administered by the respiratory route induced protective immunity against pathogenic virus challenge. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Induction and Subversion of Human Protective Immunity: Contrasting Influenza and Respiratory Syncytial Virus

    Directory of Open Access Journals (Sweden)

    Stephanie Ascough

    2018-03-01

    Full Text Available Respiratory syncytial virus (RSV and influenza are among the most important causes of severe respiratory disease worldwide. Despite the clinical need, barriers to developing reliably effective vaccines against these viruses have remained firmly in place for decades. Overcoming these hurdles requires better understanding of human immunity and the strategies by which these pathogens evade it. Although superficially similar, the virology and host response to RSV and influenza are strikingly distinct. Influenza induces robust strain-specific immunity following natural infection, although protection by current vaccines is short-lived. In contrast, even strain-specific protection is incomplete after RSV and there are currently no licensed RSV vaccines. Although animal models have been critical for developing a fundamental understanding of antiviral immunity, extrapolating to human disease has been problematic. It is only with recent translational advances (such as controlled human infection models and high-dimensional technologies that the mechanisms responsible for differences in protection against RSV compared to influenza have begun to be elucidated in the human context. Influenza infection elicits high-affinity IgA in the respiratory tract and virus-specific IgG, which correlates with protection. Long-lived influenza-specific T cells have also been shown to ameliorate disease. This robust immunity promotes rapid emergence of antigenic variants leading to immune escape. RSV differs markedly, as reinfection with similar strains occurs despite natural infection inducing high levels of antibody against conserved antigens. The immunomodulatory mechanisms of RSV are thus highly effective in inhibiting long-term protection, with disturbance of type I interferon signaling, antigen presentation and chemokine-induced inflammation possibly all contributing. These lead to widespread effects on adaptive immunity with impaired B cell memory and reduced T cell

  17. Induction and Subversion of Human Protective Immunity: Contrasting Influenza and Respiratory Syncytial Virus

    Science.gov (United States)

    Ascough, Stephanie; Paterson, Suzanna; Chiu, Christopher

    2018-01-01

    Respiratory syncytial virus (RSV) and influenza are among the most important causes of severe respiratory disease worldwide. Despite the clinical need, barriers to developing reliably effective vaccines against these viruses have remained firmly in place for decades. Overcoming these hurdles requires better understanding of human immunity and the strategies by which these pathogens evade it. Although superficially similar, the virology and host response to RSV and influenza are strikingly distinct. Influenza induces robust strain-specific immunity following natural infection, although protection by current vaccines is short-lived. In contrast, even strain-specific protection is incomplete after RSV and there are currently no licensed RSV vaccines. Although animal models have been critical for developing a fundamental understanding of antiviral immunity, extrapolating to human disease has been problematic. It is only with recent translational advances (such as controlled human infection models and high-dimensional technologies) that the mechanisms responsible for differences in protection against RSV compared to influenza have begun to be elucidated in the human context. Influenza infection elicits high-affinity IgA in the respiratory tract and virus-specific IgG, which correlates with protection. Long-lived influenza-specific T cells have also been shown to ameliorate disease. This robust immunity promotes rapid emergence of antigenic variants leading to immune escape. RSV differs markedly, as reinfection with similar strains occurs despite natural infection inducing high levels of antibody against conserved antigens. The immunomodulatory mechanisms of RSV are thus highly effective in inhibiting long-term protection, with disturbance of type I interferon signaling, antigen presentation and chemokine-induced inflammation possibly all contributing. These lead to widespread effects on adaptive immunity with impaired B cell memory and reduced T cell generation and

  18. Progress in Vaccine-Preventable and Respiratory Infectious Diseases-First 10 Years of the CDC National Center for Immunization and Respiratory Diseases, 2006-2015.

    Science.gov (United States)

    Schuchat, Anne; Anderson, Larry J; Rodewald, Lance E; Cox, Nancy J; Hajjeh, Rana; Pallansch, Mark A; Messonnier, Nancy E; Jernigan, Daniel B; Wharton, Melinda

    2018-07-01

    The need for closer linkages between scientific and programmatic areas focused on addressing vaccine-preventable and acute respiratory infections led to establishment of the National Center for Immunization and Respiratory Diseases (NCIRD) at the Centers for Disease Control and Prevention. During its first 10 years (2006-2015), NCIRD worked with partners to improve preparedness and response to pandemic influenza and other emergent respiratory infections, provide an evidence base for addition of 7 newly recommended vaccines, and modernize vaccine distribution. Clinical tools were developed for improved conversations with parents, which helped sustain childhood immunization as a social norm. Coverage increased for vaccines to protect adolescents against pertussis, meningococcal meningitis, and human papillomavirus-associated cancers. NCIRD programs supported outbreak response for new respiratory pathogens and oversaw response of the Centers for Disease Control and Prevention to the 2009 influenza A(H1N1) pandemic. Other national public health institutes might also find closer linkages between epidemiology, laboratory, and immunization programs useful.

  19. pRotective vEntilation with veno-venouS lung assisT in respiratory failure: A protocol for a multicentre randomised controlled trial of extracorporeal carbon dioxide removal in patients with acute hypoxaemic respiratory failure.

    Science.gov (United States)

    McNamee, J J; Gillies, M A; Barrett, N A; Agus, A M; Beale, R; Bentley, A; Bodenham, A; Brett, S J; Brodie, D; Finney, S J; Gordon, A J; Griffiths, M; Harrison, D; Jackson, C; McDowell, C; McNally, C; Perkins, G D; Tunnicliffe, W; Vuylsteke, A; Walsh, T S; Wise, M P; Young, D; McAuley, D F

    2017-05-01

    One of the few interventions to demonstrate improved outcomes for acute hypoxaemic respiratory failure is reducing tidal volumes when using mechanical ventilation, often termed lung protective ventilation. Veno-venous extracorporeal carbon dioxide removal (vv-ECCO 2 R) can facilitate reducing tidal volumes. pRotective vEntilation with veno-venouS lung assisT (REST) is a randomised, allocation concealed, controlled, open, multicentre pragmatic trial to determine the clinical and cost-effectiveness of lower tidal volume mechanical ventilation facilitated by vv-ECCO 2 R in patients with acute hypoxaemic respiratory failure. Patients requiring intubation and mechanical ventilation for acute hypoxaemic respiratory failure will be randomly allocated to receive either vv-ECCO 2 R and lower tidal volume mechanical ventilation or standard care with stratification by recruitment centre. There is a need for a large randomised controlled trial to establish whether vv-ECCO 2 R in acute hypoxaemic respiratory failure can allow the use of a more protective lung ventilation strategy and is associated with improved patient outcomes.

  20. Consumption of unprocessed cow's milk protects infants from common respiratory infections.

    Science.gov (United States)

    Loss, Georg; Depner, Martin; Ulfman, Laurien H; van Neerven, R J Joost; Hose, Alexander J; Genuneit, Jon; Karvonen, Anne M; Hyvärinen, Anne; Kaulek, Vincent; Roduit, Caroline; Weber, Juliane; Lauener, Roger; Pfefferle, Petra Ina; Pekkanen, Juha; Vaarala, Outi; Dalphin, Jean-Charles; Riedler, Josef; Braun-Fahrländer, Charlotte; von Mutius, Erika; Ege, Markus J

    2015-01-01

    Breast-feeding is protective against respiratory infections in early life. Given the co-evolutionary adaptations of humans and cattle, bovine milk might exert similar anti-infective effects in human infants. To study effects of consumption of raw and processed cow's milk on common infections in infants. The PASTURE birth cohort followed 983 infants from rural areas in Austria, Finland, France, Germany, and Switzerland, for the first year of life, covering 37,306 person-weeks. Consumption of different types of cow's milk and occurrence of rhinitis, respiratory tract infections, otitis, and fever were assessed by weekly health diaries. C-reactive protein levels were assessed using blood samples taken at 12 months. When contrasted with ultra-heat treated milk, raw milk consumption was inversely associated with occurrence of rhinitis (adjusted odds ratio from longitudinal models [95% CI]: 0.71 [0.54-0.94]), respiratory tract infections (0.77 [0.59-0.99]), otitis (0.14 [0.05-0.42]), and fever (0.69 [0.47-1.01]). Boiled farm milk showed similar but weaker associations. Industrially processed pasteurized milk was inversely associated with fever. Raw farm milk consumption was inversely associated with C-reactive protein levels at 12 months (geometric means ratio [95% CI]: 0.66 [0.45-0.98]). Early life consumption of raw cow's milk reduced the risk of manifest respiratory infections and fever by about 30%. If the health hazards of raw milk could be overcome, the public health impact of minimally processed but pathogen-free milk might be enormous, given the high prevalence of respiratory infections in the first year of life and the associated direct and indirect costs. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  1. CEBAF - environmental protection program plan

    International Nuclear Information System (INIS)

    1995-01-01

    An important objective in the successful operation of the Continuous Electron Beam Accelerator Facility (CEBAF) is to ensure protection of the public and the environment. To meet this objective, the Southeastern Universities Research Association, Inc., (SURA) is committed to working with the US Department of Energy (DOE) to develop, implement, and manage a sound and workable environmental protection program at CEBAF. This environmental protection plan includes information on environmental monitoring, long-range monitoring, groundwater protection, waste minimization, and pollution prevention awareness program plan

  2. History of mechanical ventilation may affect respiratory mechanics evolution in acute respiratory distress syndrome.

    Science.gov (United States)

    Koutsoukou, Antonia; Perraki, Helen; Orfanos, Stylianos E; Koulouris, Nikolaos G; Tromaropoulos, Andreas; Sotiropoulou, Christina; Roussos, Charis

    2009-12-01

    The aim of this study was to investigate the effect of mechanical ventilation (MV) before acute respiratory distress syndrome (ARDS) on subsequent evolution of respiratory mechanics and blood gases in protectively ventilated patients with ARDS. Nineteen patients with ARDS were stratified into 2 groups according to ARDS onset relative to the onset of MV: In group A (n = 11), MV was applied at the onset of ARDS; in group B (n = 8), MV had been initiated before ARDS. Respiratory mechanics and arterial blood gas were assessed in early (protectively ventilated patients with ARDS, late alteration of respiratory mechanics occurs more commonly in patients who have been ventilated before ARDS onset, suggesting that the history of MV affects the subsequent progress of ARDS even when using protective ventilation.

  3. Bioassay programs for radiation protection

    International Nuclear Information System (INIS)

    1979-01-01

    This report discusses the rationale for the establishment of bioassay programs as a means of protection for radiation workers in the nuclear industry. The bioassay program of the Radiation Protection Bureau is described for the years 1966-1978 and plans for future changes are outlined. (auth)

  4. Hanford Site grundwater protection management program

    International Nuclear Information System (INIS)

    1989-10-01

    Groundwater protection has emerged over the past few years as a national priority that has been promulgated in a variety of environmental regulations at both the state and federal level. In order to effectively coordinate and ensure compliance with applicable regulations, the US Department of Energy (DOE) requires all DOE facilities to prepare separate groundwater protection program descriptions and plans (groundwater activities were formerly included as a subpart of environmental protection programs). This document is for the Hanford Site located in the state of Washington. The DOE Order specifies that the groundwater protection management program cover the following general topical areas: (1) documentation of the groundwater regime, (2) design and implementation of a groundwater monitoring program to support resource management and comply with applicable laws and regulations, (3) a management program for groundwater protection and remediation, (4) a summary and identification of areas that may be contaminated with hazardous waste, (5) strategies for controlling these sources, (6) a remedial action program, and (7) decontamination and decommissioning and related remedial action requirements. 14 refs., 19 figs., 2 tabs

  5. A Meta-Analysis of the Association between Gender and Protective Behaviors in Response to Respiratory Epidemics and Pandemics.

    Science.gov (United States)

    Moran, Kelly R; Del Valle, Sara Y

    2016-01-01

    Respiratory infectious disease epidemics and pandemics are recurring events that levy a high cost on individuals and society. The health-protective behavioral response of the public plays an important role in limiting respiratory infectious disease spread. Health-protective behaviors take several forms. Behaviors can be categorized as pharmaceutical (e.g., vaccination uptake, antiviral use) or non-pharmaceutical (e.g., hand washing, face mask use, avoidance of public transport). Due to the limitations of pharmaceutical interventions during respiratory epidemics and pandemics, public health campaigns aimed at limiting disease spread often emphasize both non-pharmaceutical and pharmaceutical behavioral interventions. Understanding the determinants of the public's behavioral response is crucial for devising public health campaigns, providing information to parametrize mathematical models, and ultimately limiting disease spread. While other reviews have qualitatively analyzed the body of work on demographic determinants of health-protective behavior, this meta-analysis quantitatively combines the results from 85 publications to determine the global relationship between gender and health-protective behavioral response. The results show that women in the general population are about 50% more likely than men to adopt/practice non-pharmaceutical behaviors. Conversely, men in the general population are marginally (about 12%) more likely than women to adopt/practice pharmaceutical behaviors. It is possible that factors other than pharmaceutical/non-pharmaceutical status not included in this analysis act as moderators of this relationship. These results suggest an inherent difference in how men and women respond to epidemic and pandemic respiratory infectious diseases. This information can be used to target specific groups when developing non-pharmaceutical public health campaigns and to parameterize epidemic models incorporating demographic information.

  6. A Meta-Analysis of the Association between Gender and Protective Behaviors in Response to Respiratory Epidemics and Pandemics.

    Directory of Open Access Journals (Sweden)

    Kelly R Moran

    Full Text Available Respiratory infectious disease epidemics and pandemics are recurring events that levy a high cost on individuals and society. The health-protective behavioral response of the public plays an important role in limiting respiratory infectious disease spread. Health-protective behaviors take several forms. Behaviors can be categorized as pharmaceutical (e.g., vaccination uptake, antiviral use or non-pharmaceutical (e.g., hand washing, face mask use, avoidance of public transport. Due to the limitations of pharmaceutical interventions during respiratory epidemics and pandemics, public health campaigns aimed at limiting disease spread often emphasize both non-pharmaceutical and pharmaceutical behavioral interventions. Understanding the determinants of the public's behavioral response is crucial for devising public health campaigns, providing information to parametrize mathematical models, and ultimately limiting disease spread. While other reviews have qualitatively analyzed the body of work on demographic determinants of health-protective behavior, this meta-analysis quantitatively combines the results from 85 publications to determine the global relationship between gender and health-protective behavioral response. The results show that women in the general population are about 50% more likely than men to adopt/practice non-pharmaceutical behaviors. Conversely, men in the general population are marginally (about 12% more likely than women to adopt/practice pharmaceutical behaviors. It is possible that factors other than pharmaceutical/non-pharmaceutical status not included in this analysis act as moderators of this relationship. These results suggest an inherent difference in how men and women respond to epidemic and pandemic respiratory infectious diseases. This information can be used to target specific groups when developing non-pharmaceutical public health campaigns and to parameterize epidemic models incorporating demographic information.

  7. Do 12-Week Yoga Program Influence Respiratory Function Of Elderly Women?

    Directory of Open Access Journals (Sweden)

    Bezerra Lídia Aguiar

    2014-12-01

    Full Text Available Aging produces several respiratory limitations and reduces tolerance to physical efforts, sometimes leading to pulmonary diseases in the elderly. The literature draws attention to the possible benefits of Yoga practice among the elderly, presenting evidence for significant improvements in quality of life. It was hypothesized that yoga practice can improve respiratory function in the elderly. The effects of a yoga program on pulmonary volumes and respiratory muscle strength were verified in 36 elderly women divided into a yoga group [YG] (63.1 ± 13.3 years of age and a control group (61.0 ± 6.9 years of age. Maximal inspiratory and expiratory pressure (MIP and MEP were assessed by a manovacuometer and tidal volume (VT, vital capacity (VC and minute ventilation (VE were measured by a ventilometer. The program comprised 65 min sessions, 3 times/week during 12 weeks. The heart rate and respiratory rate decreased significantly in the YG (76-39 ± 8-03 vs. 74-61±10.26 bpm and 18.61 ± 3.15 vs. 16.72 ± 3.12 resp/min, respectively. In the YG, VT and VE increased significantly (0.55 ± 0.22 vs. 0.64 ± 0.2 ml and 9.19 ± 2.39 vs. 10.05 ± 2.11 ml, respectively, as well as VC (1.48 ± 0.45 vs. 2.03 ± 0.72 ml. Improvements were also found in MIP and MEP in the YG (62.17 ± 14.77 vs. 73.06 ± 20.16 cmH2O and 80.56 ± 23.94 vs. 86.39 ± 20.16 cmH2O, respectively. It was concluded that a 12-week yoga program significantly improves pulmonary function of aged women.

  8. Do 12-week yoga program influence respiratory function of elderly women?

    Science.gov (United States)

    Bezerra, Lídia Aguiar; de Melo, Helton Fabrício; Garay, Ana Paula; Reis, Victor Machado; Aidar, Felipe José; Bodas, Ana Rita; Garrido, Nuno Domingos; de Oliveira, Ricardo Jacó

    2014-09-29

    Aging produces several respiratory limitations and reduces tolerance to physical efforts, sometimes leading to pulmonary diseases in the elderly. The literature draws attention to the possible benefits of Yoga practice among the elderly, presenting evidence for significant improvements in quality of life. It was hypothesized that yoga practice can improve respiratory function in the elderly. The effects of a yoga program on pulmonary volumes and respiratory muscle strength were verified in 36 elderly women divided into a yoga group [YG] (63.1 ± 13.3 years of age) and a control group (61.0 ± 6.9 years of age). Maximal inspiratory and expiratory pressure (MIP and MEP) were assessed by a manovacuometer and tidal volume (VT), vital capacity (VC) and minute ventilation (VE) were measured by a ventilometer. The program comprised 65 min sessions, 3 times/week during 12 weeks. The heart rate and respiratory rate decreased significantly in the YG (76-39 ± 8-03 vs. 74-61±10.26 bpm and 18.61 ± 3.15 vs. 16.72 ± 3.12 resp/min, respectively). In the YG, VT and VE increased significantly (0.55 ± 0.22 vs. 0.64 ± 0.2 ml and 9.19 ± 2.39 vs. 10.05 ± 2.11 ml, respectively), as well as VC (1.48 ± 0.45 vs. 2.03 ± 0.72 ml). Improvements were also found in MIP and MEP in the YG (62.17 ± 14.77 vs. 73.06 ± 20.16 cmH2O and 80.56 ± 23.94 vs. 86.39 ± 20.16 cmH2O, respectively). It was concluded that a 12-week yoga program significantly improves pulmonary function of aged women.

  9. Respiratory fit testing for farmworkers in the Black Dirt region of Hudson Valley, New York.

    Science.gov (United States)

    Earle-Richardson, Giulia; Fiske, Todd; Wyckoff, Sherry; Shuford, James; May, John

    2014-01-01

    Respiratory protection in agriculture has lagged behind other industries. Migrant farmworkers often work in dusty environments yet do not receive appropriate, fitted respiratory protection. During May and June of 2013, researchers pilot-tested a respiratory protection program adapted to fit the unique needs of migrant and seasonal farmworkers. It was implemented in Spanish, with literacy support, at convenient times and locations. Additionally, staff was known to workers, and a farmworker medical center provided medical follow-up. Fifty-six farmworkers participated (68%; 82 invited). Of the participants, 88% were male; 20% reported using respiratory protection. One worker had been fit tested previously; 57% reported being exposed to pesticides. All but six farmworkers passed the medical clearance (91%). The mask most commonly fit to the American-born population was a good fit for only 41% of Latino farmworkers. The fact that two thirds of invited farmworkers participated in the clearance and over half completed mask fitting indicates that the modified protocol meets farmworker needs. A wide range of mask types should be made available for Latino farmworkers.

  10. Bactericidal/Permeability-increasing protein fold-containing family member A1 in airway host protection and respiratory disease.

    Science.gov (United States)

    Britto, Clemente J; Cohn, Lauren

    2015-05-01

    Bactericidal/permeability-increasing protein fold-containing family member A1 (BPIFA1), formerly known as SPLUNC1, is one of the most abundant proteins in respiratory secretions and has been identified with increasing frequency in studies of pulmonary disease. Its expression is largely restricted to the respiratory tract, being highly concentrated in the upper airways and proximal trachea. BPIFA1 is highly responsive to airborne pathogens, allergens, and irritants. BPIFA1 actively participates in host protection through antimicrobial, surfactant, airway surface liquid regulation, and immunomodulatory properties. Its expression is modulated in multiple lung diseases, including cystic fibrosis, chronic obstructive pulmonary disease, respiratory malignancies, and idiopathic pulmonary fibrosis. However, the role of BPIFA1 in pulmonary pathogenesis remains to be elucidated. This review highlights the versatile properties of BPIFA1 in antimicrobial protection and its roles as a sensor of environmental exposure and regulator of immune cell function. A greater understanding of the contribution of BPIFA1 to disease pathogenesis and activity may clarify if BPIFA1 is a biomarker and potential drug target in pulmonary disease.

  11. Protection by recombinant viral proteins against a respiratory challenge with virulent avian metapneumovirus.

    Science.gov (United States)

    Chary, Parag; Njenga, M Kariuki; Sharma, Jagdev M

    2005-12-15

    Protection by recombinant avian metapneumovirus (aMPV) N or M proteins against a respiratory challenge with virulent aMPV was examined. N, M or N+M proteins were administered intramuscularly (IM) with incomplete Freund's adjuvant (IFA) or by the oculonasal (ON) route with cholera toxin-B (CTB). Each turkey received 40 or 80 microg of each recombinant protein. Birds were considered protected against challenge if the challenge virus was not detectable in the choanal swabs by RT-PCR. At a dose of 40 microg/bird, N protein given with IFA by the IM route protected eight out of nine birds. M protein at the same dose protected three out of seven birds, while a combination of N+M proteins (40 microg each) protected three out of four birds. At a dose of 80 microg of each of N and M proteins per bird given with IFA by the IM route, 100% protection was achieved. ON immunization with a mixture of N and M proteins induced partial protection when the proteins were given with CTB; no detectable protection was noted without CTB. N and M proteins induced anti-aMPV antibodies, although protection against virulent virus challenge did not appear to be associated with the level or presence of antibodies.

  12. Safety and protective efficacy of porcine reproductive and respiratory syndrome recombinant virus vaccines in young pigs.

    NARCIS (Netherlands)

    Verheije, M.H.; Kroese, M.V.; Linden, van der I.F.A.; Boer-Luijtze, de E.A.; Rijn, van P.A.; Pol, J.M.A.; Meulenberg, J.J.M.; Steverink, P.J.G.M.

    2003-01-01

    Three porcine reproductive and respiratory syndrome virus (PRRSV) recombinants, generated by mutagenesis of an infectious cDNA clone of the Lelystad virus (LV) isolate, were tested for their safety and protective efficacy as potential PRRSV vaccines in pigs. Recombinant vABV688 contains two amino

  13. Nevada Test Site Radiation Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council, Nevada Test Site

    2007-08-09

    Title 10 Code of Federal Regulations (CFR) 835, 'Occupational Radiation Protection', establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (onsite or offsite) DOE National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration offsite projects.

  14. Radiological protection Program of CDTN

    International Nuclear Information System (INIS)

    1983-01-01

    Radiological protection program of CDTN, its purposes and rules, responsabilities, physical control, monitoring, personnel radiation protection, radiation sources and radioactive wastes control, emergency and accidents and siting are described. (C.M.) [pt

  15. Grepafloxacin Clinical Program for Lower Respiratory Tract Infections

    Directory of Open Access Journals (Sweden)

    Arne C Rodloff

    1998-01-01

    Full Text Available The present paper evaluates the clinical trial program in lower respiratory tract infections treated with a new fluoroquinolone antibiotic, grepafloxacin. Unlike older quinolones, grepafloxacin has excellent activity against Gram-positive organisms, which include Streptococcus pneumoniae and “atypical” pathogens Legionella species. Mycoplasma pneumoniae and Chlamydia pneumoniae. Grepafloxacin has a long half-life of 12 to 15 h, which allows once daily dosing. Six studies have been conducted regarding community-acquired lower respiratory tract infections (LRTls, four about community-acquired pneumonia (CAP and two about acute bacterial exacerbations of chronic bronchitis (ABECB . In these studies, grepafloxacin demonstrated clinical equivalence with standard therapies. but, in patients with documented infections. grepafloxacin was statistically superior to amoxycillin in both CAP and ABECB. The new fluoroquinolone has a good safety profile, comparable with that of ciprofloxacin. The most common adverse effects of grepafloxacin were nausea and a metallic taste; however, these effects resulted in only a few discontinuations of therapy. With the increasing prevalence of resistance in pathogens isolated from community-acquired LRTIs, grepafloxacin offers a good alternative for monotherapy in these patients.

  16. Occupational Pesticide Exposures and Respiratory Health

    Science.gov (United States)

    Ye, Ming; Beach, Jeremy; Martin, Jonathan W.; Senthilselvan, Ambikaipakan

    2013-01-01

    Pesticides have been widely used to control pest and pest-related diseases in agriculture, fishery, forestry and the food industry. In this review, we identify a number of respiratory symptoms and diseases that have been associated with occupational pesticide exposures. Impaired lung function has also been observed among people occupationally exposed to pesticides. There was strong evidence for an association between occupational pesticide exposure and asthma, especially in agricultural occupations. In addition, we found suggestive evidence for a link between occupational pesticide exposure and chronic bronchitis or COPD. There was inconclusive evidence for the association between occupational pesticide exposure and lung cancer. Better control of pesticide uses and enforcement of safety behaviors, such as using personal protection equipment (PPE) in the workplace, are critical for reducing the risk of developing pesticide-related symptoms and diseases. Educational training programs focusing on basic safety precautions and proper uses of personal protection equipment (PPE) are possible interventions that could be used to control the respiratory diseases associated with pesticide exposure in occupational setting. PMID:24287863

  17. 75 FR 5697 - Employee Protection Program; Removal

    Science.gov (United States)

    2010-02-04

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary 14 CFR Part 314 RIN 2105-AD94 Employee... Employee Protection Program. These regulations are removed because the underlying program was repealed by... Employee Protection Program, to be administered by the U.S. Department of Transportation. Section 43 of the...

  18. Establishments of scientific radiation protection management program

    International Nuclear Information System (INIS)

    Pan Ziqiang

    1988-01-01

    Some aspects for establishing the radiation protection management program have been discussed. Radiation protection management program includes: definite aims of management, complete data register, strict supervision system, and scientific management methodology

  19. [Treatment of acute respiratory distress syndrome using pressure and volume controlled ventilation with lung protective strategy].

    Science.gov (United States)

    Ge, Ying; Wan, Yong; Wang, Da-qing; Su, Xiao-lin; Li, Jun-ying; Chen, Jing

    2004-07-01

    To investigate the significance and effect of pressure controlled ventilation (PCV) as well as volume controlled ventilation (VCV) by lung protective strategy on respiratory mechanics, blood gas analysis and hemodynamics in patients with acute respiratory distress syndrome (ARDS). Fifty patients with ARDS were randomly divided into PCV and VCV groups with permissive hypercapnia and open lung strategy. Changes in respiratory mechanics, blood gas analysis and hemodynamics were compared between two groups. Peak inspiration pressure (PIP) in PCV group was significantly lower than that in VCV group, while mean pressure of airway (MPaw) was significantly higher than that in VCV after 24 hours mechanical ventilation. After 24 hours mechanical ventilation, there were higher central venous pressure (CVP) and slower heart rate (HR) in two groups, CVP was significantly higher in VCV compared with PCV, and PCV group had slower HR than VCV group, the two groups had no differences in mean blood pressure (MBP) at various intervals. All patients showed no ventilator-induced lung injury. Arterial blood oxygenations were obviously improved in two groups after 24 hours mechanical ventilation, PCV group had better partial pressure of oxygen in artery (PaO2) than VCV group. Both PCV and VCV can improve arterial blood oxygenations, prevent ventilator-induced lung injury, and have less disturbance in hemodynamic parameters. PCV with lung protective ventilatory strategy should be early use for patients with ARDS.

  20. Hanford Site Groundwater Protection Management Program: Revision 1

    International Nuclear Information System (INIS)

    1993-11-01

    Groundwater protection is a national priority that is promulgated in a variety of environmental regulations at local, state, and federal levels. To effectively coordinate and ensure compliance with applicable regulations, the US Department of Energy has issued DOE Order 5400.1 (now under revision) that requires all US Department of Energy facilities to prepare separate groundwater protection program descriptions and plans. This document describes the Groundwater Protection Management Program for the Hanford Site located in the state of Washington. DOE Order 5400.1 specifies that the Groundwater Protection Management Program cover the following general topical areas: (1) documentation of the groundwater regime, (2) design and implementation of a groundwater monitoring program to support resource management and comply with applicable laws and regulations, (3) a management program for groundwater protection and remediation, (4) a summary and identification of areas that may be contaminated with hazardous waste, (5) strategies for controlling these sources, (6) a remedial action program, and (7) decontamination and decommissioning and related remedial action requirements. Many of the above elements are covered by existing programs at the Hanford Site; thus, one of the primary purposes of this document is to provide a framework for coordination of existing groundwater protection activities. Additionally, it describes how information needs are identified and can be incorporated into existing or proposed new programs. The Groundwater Protection Management Program provides the general scope, philosophy, and strategies for groundwater protection/management at the Hanford Site. Subtier documents provide the detailed plans for implementing groundwater-related activities and programs. Related schedule and budget information are provided in the 5-year plan for environmental restoration and waste management at the Hanford Site

  1. Inactivity-induced respiratory plasticity: Protecting the drive to breathe in disorders that reduce respiratory neural activity☆

    Science.gov (United States)

    Strey, K.A.; Baertsch, N.A.; Baker-Herman, T.L.

    2013-01-01

    Multiple forms of plasticity are activated following reduced respiratory neural activity. For example, in ventilated rats, a central neural apnea elicits a rebound increase in phrenic and hypoglossal burst amplitude upon resumption of respiratory neural activity, forms of plasticity called inactivity-induced phrenic and hypoglossal motor facilitation (iPMF and iHMF), respectively. Here, we provide a conceptual framework for plasticity following reduced respiratory neural activity to guide future investigations. We review mechanisms giving rise to iPMF and iHMF, present new data suggesting that inactivity-induced plasticity is observed in inspiratory intercostals (iIMF) and point out gaps in our knowledge. We then survey conditions relevant to human health characterized by reduced respiratory neural activity and discuss evidence that inactivity-induced plasticity is elicited during these conditions. Understanding the physiological impact and circumstances in which inactivity-induced respiratory plasticity is elicited may yield novel insights into the treatment of disorders characterized by reductions in respiratory neural activity. PMID:23816599

  2. Respiratory Health Symptoms among Schoolchildren in Relation to Possible Food-Related Risk and Protective Factors.

    Science.gov (United States)

    Wright, Caradee Y; Nkosi, Vusumuzi; Wichmann, Janine

    2018-03-13

    Respiratory health outcomes are among the top five causes of child morbidity and mortality around the world. We aimed to investigate possible food-related risk and protective factors for respiratory health outcomes in children. Structured questionnaires completed by primary caregivers of 10-year old children were used to collect information on demographics, socio-economic status, house characteristics and child respiratory health status. Upper (URIs) and Lower (LRIs) respiratory illnesses comprised hay fever, and wheezing, asthma and bronchitis, respectively. Eight hundred questionnaires were distributed, 648 retrieved and 420 completed in full (52.5% response rate). The hay fever 6-month prevalence was 22.4% and wheezing had the highest 6-month prevalence among the LRIs (13.8%). The majority of children ate vegetables (75.5%), fruit (69.3%) and chicken or fish (81.7%) regularly. Nearly half of the children (45.5%) regularly ate processed food. Eating processed food regularly was statistical significantly associated with wheeze (Adjusted Odds Ratio (OR) = 2.65; 95% CI: 1.38-5.08), hay fever (OR = 1.62; 95% CI: 1.09-2.64) and bronchitis (OR = 1.27; 95% CI: 1.06-2.56). The study found an association between regular consumption of processed foods and wheeze, hay fever and bronchitis among 10 year old children. The regular consumption of processed food plays a role in adverse respiratory health effects among children and healthy eating is emphasized.

  3. Protective effects of Mucuna pruriens seed extract pretreatment against cardiovascular and respiratory depressant effects of Calloselasma rhodostoma (Malayan pit viper) venom in rats.

    Science.gov (United States)

    Fung, S Y; Tan, N H; Sim, S M

    2010-12-01

    The protective effects of Mucuna pruriens seed extract (MPE) against the cardio-respiratory depressant and neuromuscular paralytic effects induced by injection of Calloselasma rhodostoma (Malayan pit viper) venom in anaesthetized rats were investigated. While MPE pretreatment did not reverse the inhibitory effect of the venom on the gastrocnemius muscle excitability, it significantly attenuated the venom-induced cardio-respiratory depressant effects (p < 0.05). The protection effects may have an immunological mechanism, as indicated by the presence of several proteins in the venom that are immunoreactive against anti-MPE. However, we cannot rule out the possibility that the pretreatment may exert a direct, non-immunological protective action against the venom.

  4. Coal Mining-Related Respiratory Diseases

    Science.gov (United States)

    ... Topics Publications and Products Programs Contact NIOSH NIOSH COAL WORKERS' HEALTH SURVEILLANCE PROGRAM Recommend on Facebook Tweet Share Compartir Coal Mining-Related Respiratory Diseases Coal mining-related respiratory ...

  5. EPRI Guide to Managing Nuclear Utility Protective Clothing Programs

    International Nuclear Information System (INIS)

    Kelly, J.J.; Kelly, D.M.

    1993-10-01

    The Electric Power Research Institute (EPRI) commissioned a radioactive waste related project (RP2414-34) in 1989 to produce a guide for developing and managing nuclear plant protective clothing programs. Every nuclear facility must coordinate some type of protective clothing program for its radiation workers to ensure proper and safe protection for the wearer and to maintain control over the spread of contamination. Yet, every nuclear facility has developed its own unique program for managing such clothing. Accordingly, a need existed for a reference guide to assist with standardizing protective clothing programs and in controlling the potentially escalating economics of such programs. The initial Guide to Managing Nuclear Utility Protective Clothing Programs, NP-7309, was published in May 1991. Since that time, a number of utilities have reviewed and/or used the report to enhance their protective clothing programs. Some of these utilities requested that a computer program be developed to assist utilities in evaluating the economics of protective clothing programs consistent with the guidance in NP-7309. The PCEVAL computer code responds to that industry need. This report, the PCEVAL User's Manual, provides detailed instruction on use of the software

  6. Mars Technology Program Planetary Protection Technology Development

    Science.gov (United States)

    Lin, Ying

    2006-01-01

    The objectives of the NASA Planetary Protection program are to preserve biological and organic conditions of solar-system bodies for future scientific exploration and to protect the Earth from potential hazardous extraterrestrial contamination. As the exploration of solar system continues, NASA remains committed to the implementation of planetary protection policy and regulations. To fulfill this commitment, the Mars Technology Program (MTP) has invested in a portfolio of tasks for developing necessary technologies to meet planetary protection requirements for the next decade missions.

  7. Hand Hygiene Program Decreases School Absenteeism Due to Upper Respiratory Infections

    Science.gov (United States)

    Azor-Martinez, Ernestina; Cobos-Carrascosa, Elena; Seijas-Vazquez, Maria Luisa; Fernández-Sánchez, Carmen; Strizzi, Jenna M.; Torres-Alegre, Pilar; Santisteban-Martínez, Joaquin; Gimenez-Sanchez, Francisco

    2016-01-01

    Background: We assessed the effectiveness of a handwashing program using hand sanitizer to prevent school absenteeism due to upper respiratory infections (URIs). Methods: This was a randomized, controlled, and open study on a sample of 1341 children 4-12 years old, attending 5 state schools in Almería (Spain), with an 8-month follow-up. The…

  8. An improvement of the child acute respiratory infection treatment program

    OpenAIRE

    E. N. Simovan'yan; E. E. Badalyants; L. P. Sizyakina; A. A. Lebedenko; V. B. Denisenko; M. A. Kim

    2013-01-01

    High morbidity rate, frequent development of severe complication forms, unfavorable remote effects for children’s health, insufficient efficacy of the used acute respiratory infection therapy schemes necessitate a treatment program improvement for this group of diseases. A complex clinical-laboratory examination of 72 3-6-year-old children with acute nasopharyngites and bronchites was conducted. Dependence of the disease’s clinical form and course peculiarities from the premorbid setting stat...

  9. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false DOP filter test; respirators designed as... filter test; respirators designed as respiratory protection against dusts, fumes, and mists having an air...) All single air-purifying respirator filter units will be tested in an atmosphere concentration of 100...

  10. Attenuation of earmuffs used simultaneously with respiratory protective devices

    Directory of Open Access Journals (Sweden)

    Emil Kozłowski

    2017-06-01

    Full Text Available Background: In the work environment, apart from the noise, employees may be exposed to other harmful factors. Therefore, they wear hearing protectors and other personal protective equipment. The aim of the study was to determine whether simultaneous use of earmuffs and respiratory protective devices affects the attenuation of earmuffs. Material and Methods: The study was conducted in laboratory conditions using the subjective REAT (Real Ear Attenuation at Threshold and objective MIRE (Microphone in Real Ear methods. The REAT method was used to measure sound attenuation of earmuffs, while MIRE was used to determine changes in attenuation of earmuffs due to the use of other personal protective equipment. Results: The study showed reduction in attenuation of earmuffs due to the use of a full face mask up to 20 dB. Using a full face mask causes that attenuation of earmuffs in the low frequency range is close to zero. Reduction in attenuation due to the use of half masks for complete with particle filters (half masks is 3–15 dB. Simultaneous use of earmuffs and filtering half masks makes small changes in attenuation not exceeding 3 dB. Conclusions: The study showed that full face masks give the greatest reduction in attenuation of earmuffs. On the other hand, the least reduction is observed in the case of filtering half masks. There is a significant difference between the reduction in attenuation of earmuffs worn with half masks for complete with particle filters because they may be equipped with different kind of the head strap. Med Pr 2017;68(3:349–361

  11. Ground-Water Protection and Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, P.E.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the ground-water protection and monitoring program strategy for the Hanford Site in 1994. Two of the key elements of this strategy are to (1) protect the unconfined aquifer from further contamination, and (2) conduct a monitoring program to provide early warning when contamination of ground water does occur. The monitoring program at Hanford is designed to document the distribution and movement of existing ground-water contamination and provides a historical baseline for evaluating current and future risk from exposure to the contamination and for deciding on remedial action options.

  12. Ground-Water Protection and Monitoring Program

    International Nuclear Information System (INIS)

    Dresel, P.E.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the ground-water protection and monitoring program strategy for the Hanford Site in 1994. Two of the key elements of this strategy are to (1) protect the unconfined aquifer from further contamination, and (2) conduct a monitoring program to provide early warning when contamination of ground water does occur. The monitoring program at Hanford is designed to document the distribution and movement of existing ground-water contamination and provides a historical baseline for evaluating current and future risk from exposure to the contamination and for deciding on remedial action options

  13. Effects of lung protective mechanical ventilation associated with permissive respiratory acidosis on regional extra-pulmonary blood flow in experimental ARDS.

    Science.gov (United States)

    Hering, Rudolf; Kreyer, Stefan; Putensen, Christian

    2017-10-27

    Lung protective mechanical ventilation with limited peak inspiratory pressure has been shown to affect cardiac output in patients with ARDS. However, little is known about the impact of lung protective mechanical ventilation on regional perfusion, especially when associated with moderate permissive respiratory acidosis. We hypothesized that lung protective mechanical ventilation with limited peak inspiratory pressure and moderate respiratory acidosis results in an increased cardiac output but unequal distribution of blood flow to the different organs of pigs with oleic-acid induced ARDS. Twelve pigs were enrolled, 3 died during instrumentation and induction of lung injury. Thus, 9 animals received pressure controlled mechanical ventilation with a PEEP of 5 cmH 2 O and limited peak inspiratory pressure (17 ± 4 cmH 2 O) versus increased peak inspiratory pressure (23 ± 6 cmH 2 O) in a crossover-randomized design and were analyzed. The sequence of limited versus increased peak inspiratory pressure was randomized using sealed envelopes. Systemic and regional hemodynamics were determined by double indicator dilution technique and colored microspheres, respectively. The paired student t-test and the Wilcoxon test were used to compare normally and not normally distributed data, respectively. Mechanical ventilation with limited inspiratory pressure resulted in moderate hypercapnia and respiratory acidosis (PaCO 2 71 ± 12 vs. 46 ± 9 mmHg, and pH 7.27 ± 0.05 vs. 7.38 ± 0.04, p respiratory acidosis was associated with an increase in cardiac output. However, the better systemic blood flow was not uniformly directed to the different organs. This observation may be of clinical interest in patients, e.g. with cardiac, renal and cerebral pathologies.

  14. A new sampler for simulating aerosol deposition in the respiratory tract

    International Nuclear Information System (INIS)

    Li Dehong; Zhuo Weihai; Yi Yanling; Chen Bo; Liu Haikuan

    2008-01-01

    For estimation of the deposition fractions of radon progeny in different regions of the respiratory tract, a new sampler consisting of three different configurations of sampling heads was developed. The deposition fractions of aerosols on the wire screens inside the sampling heads were calculated with the fan model of filtration theory. The deposition fractions of aerosols in different regions of the respiratory tract were calculated with the lung dose evaluation program (LUDEP) developed by National Radiological Protection Board (NRPB) as references. In general indoor and mine environments, the deviation between the deposition fractions of attached aerosol on the wire screens designed in this study and its reference values in the respiratory tract is less than 5%. It is possible to accurately estimate the deposition fractions of radon progeny in different regions of the respiratory tract through mimic measurements of radon progeny collected with the new sampler. (authors)

  15. 76 FR 44372 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Respiratory...

    Science.gov (United States)

    2011-07-25

    ... for OMB Review; Comment Request; Respiratory Protection Standard ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Respiratory Protection Standard,'' to the Office of Management... Respiratory Protection Standard outlined in 29 CFR 1910.134 assists employers in protecting the health of...

  16. Y-12 Site environmental protection program implementation plan (EPPIP)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The Y-12 Plant Environmental Protection Program is conducted to: (1) protect public health and the environment from chemical and radiological releases occurring from current plant operations and past waste management and operational practices; (2) ensure compliance with federal, state, and local environmental regulations and DOE directives; (3) identify potential environmental problems; (4) evaluate existing environmental contamination and determine the need for remedial actions and mitigative measures; (5) monitor the progress of ongoing remedial actions and cleanup measures; and (6) inform the public of environmental issues relating to DOE operations. DOE Order 5400.1, General Environmental Protection Program, defines the general requirements for environmental protection programs at DOE facilities. This Environmental Protection Program Implementation Plan (EPPIP) defines the methods by which the Y-12 Plant staff will comply with the order by: (1) referencing environmental protection goals and objectives and identifying strategies and timetables for attaining them; (2) providing the overall framework for the design and implementation of the Y-12 Environmental Protection Program; and (3) assigning responsibilities for complying with the requirements of the order. The EPPIP is revised and updated annually.

  17. Y-12 Site environmental protection program implementation plan (EPPIP)

    International Nuclear Information System (INIS)

    1996-11-01

    The Y-12 Plant Environmental Protection Program is conducted to: (1) protect public health and the environment from chemical and radiological releases occurring from current plant operations and past waste management and operational practices; (2) ensure compliance with federal, state, and local environmental regulations and DOE directives; (3) identify potential environmental problems; (4) evaluate existing environmental contamination and determine the need for remedial actions and mitigative measures; (5) monitor the progress of ongoing remedial actions and cleanup measures; and (6) inform the public of environmental issues relating to DOE operations. DOE Order 5400.1, General Environmental Protection Program, defines the general requirements for environmental protection programs at DOE facilities. This Environmental Protection Program Implementation Plan (EPPIP) defines the methods by which the Y-12 Plant staff will comply with the order by: (1) referencing environmental protection goals and objectives and identifying strategies and timetables for attaining them; (2) providing the overall framework for the design and implementation of the Y-12 Environmental Protection Program; and (3) assigning responsibilities for complying with the requirements of the order. The EPPIP is revised and updated annually

  18. [Respiratory function evaluation in welders taking into account tecnological evolution of individual protection dispositive and risk specific information].

    Science.gov (United States)

    Boggia, B; Graziuso, G; Carbone, U

    2011-01-01

    Aim of the study is to evaluate the effect of specific information program on DPI use on the functional respiratory parameters in a group of 15 welders compared with 18 welders not included in the program and 18 workers of industrial sector. Spirometryc parameters were recorded and compared and the results pointed out a significant increase of FEV1 and FVC in the study group compared with welder out of the study while no difference were observed between study group and workers of industrial sector. Results shown that the correct use of DPI could reduce the effects of welding fumes on respiratory tract making these effects equal to the exposure to industrial dusts.

  19. Conducting an inspection of protection program operations

    International Nuclear Information System (INIS)

    Brown, S.; Howell, J.

    1987-01-01

    Protection Program Operations (PPO) encompasses the entire physical security program at a facility, including security construction and equipment, procedures, forces, management and supervision, and the integration of these elements into a total system. PPO subtopics are Physical Security Systems (PSS), Protection Forces (PF), and System Performance Tests (SPT). PSS assesses those security elements designed to protect security interests, and include sensors, surveillance devices, systems for transmission and integration of alarm and assessment information, barriers, lighting, etc. PF assesses the management, training, equipment and facilities, and skills and knowledge of the protective force. SPT includes Force-on-Force, Emergency Management Performance Test, and Limited Scope Performance Tests

  20. Protection against Porcine Reproductive and Respiratory Syndrome Virus (PRRSV) Infection through Passive Transfer of PRRSV-Neutralizing Antibodies Is Dose Dependent▿ †

    OpenAIRE

    Lopez, O. J.; Oliveira, M. F.; Garcia, E. Alvarez; Kwon, B. J.; Doster, A.; Osorio, F. A.

    2007-01-01

    Previous work in our laboratory demonstrated that passive transfer of porcine reproductive and respiratory syndrome virus (PRRSV)-neutralizing antibodies (NA) protected pregnant sows against reproductive failure and conferred sterilizing immunity in sows and offspring. We report here on the dose requirement for protection by passive transfer with NA in young weaned pigs. The presence of a 1:8 titer of PRRSV-NA in serum consistently protected pigs against viremia. Nevertheless, their lungs, to...

  1. 42 CFR 84.52 - Respiratory hazards; classification.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...

  2. Radiation Protection of Patients program (Argentina)

    International Nuclear Information System (INIS)

    Touzet, R.; Perez, M. R.; Buzzi, A.; Andisco, D.

    2006-01-01

    After an initial period of conviction for installing an active discussion on Radiation Protection of Patients inside the medical community, there were organized working groups in Radiodiagnosis, Radiotherapy, Nuclear Medicine and on radiation protection of pregnant women. These groups began systematical activities, which received a strong institutional support of the Argentine Society of Radiology, toward the implementation of a Program of RPP that is being put nowadays into practice. This program has three aims and a series of targets to be fulfilled in successive stages: Basic aims and short term targets: 1) To guarantee the Justification. First goal: Development of the Prescription Guide (achieve) 2) To optimize the radioprotection: First goal: Development of a Manual of Procedures (achieved) 3) To prevent potential exposures. First goal: Design of a Basic Quality System in Health (achieved) The effective participation of the professional's and technician's associations in the development of the program of radiological protection of the patient is a key aspect for the success. (Author)

  3. Respiratory syncytial virus fusion glycoprotein expressed in insect cells form protein nanoparticles that induce protective immunity in cotton rats.

    Directory of Open Access Journals (Sweden)

    Gale Smith

    Full Text Available Respiratory Syncytial Virus (RSV is an important viral agent causing severe respiratory tract disease in infants and children as well as in the elderly and immunocompromised individuals. The lack of a safe and effective RSV vaccine represents a major unmet medical need. RSV fusion (F surface glycoprotein was modified and cloned into a baculovirus vector for efficient expression in Sf9 insect cells. Recombinant RSV F was glycosylated and cleaved into covalently linked F2 and F1 polypeptides that formed homotrimers. RSV F extracted and purified from insect cell membranes assembled into 40 nm protein nanoparticles composed of multiple RSV F oligomers arranged in the form of rosettes. The immunogenicity and protective efficacy of purified RSV F nanoparticles was compared to live and formalin inactivated RSV in cotton rats. Immunized animals induced neutralizing serum antibodies, inhibited virus replication in the lungs, and had no signs of disease enhancement in the respiratory track of challenged animals. RSV F nanoparticles also induced IgG competitive for binding of palivizumab neutralizing monoclonal antibody to RSV F antigenic site II. Antibodies to this epitope are known to protect against RSV when passively administered in high risk infants. Together these data provide a rational for continued development a recombinant RSV F nanoparticle vaccine candidate.

  4. Preventative programs for respiratory disease in cow/calf operations.

    Science.gov (United States)

    Engelken, T J

    1997-11-01

    Control of respiratory disease in cow/calf operations presents many challenges. The incidence of disease in the suckling calf is not well documented and the logistics of handling range animals make control programs difficult to implement. Health programs have to be built around normal working patterns, and these patterns may not provide the best "fit" for immune management of the calf. Weaned calves undergo significant disease challenge when they enter typical marketing channels. This provides the potential for high levels of calf morbidity, mortality, medicine costs, and losses from decreased performance as they arrive at a stocker operation or feedyard. If preweaning calf health and preconditioning programs are used, they must be planned so that the producer has an opportunity to obtain a return on their investment. Options for increasing calf weight marketed, certified calf health sales, or retained ownership through the next phase of production should be evaluated carefully. Any potential increase in calf value must be weighed against program costs. This affords the veterinarian an opportunity to build on traditional disease management and prevention skills and expand their influence in overall ranch management.

  5. An Epithelial Integrin Regulates the Amplitude of Protective Lung Interferon Responses against Multiple Respiratory Pathogens.

    Directory of Open Access Journals (Sweden)

    Victoria A Meliopoulos

    2016-08-01

    Full Text Available The healthy lung maintains a steady state of immune readiness to rapidly respond to injury from invaders. Integrins are important for setting the parameters of this resting state, particularly the epithelial-restricted αVβ6 integrin, which is upregulated during injury. Once expressed, αVβ6 moderates acute lung injury (ALI through as yet undefined molecular mechanisms. We show that the upregulation of β6 during influenza infection is involved in disease pathogenesis. β6-deficient mice (β6 KO have increased survival during influenza infection likely due to the limited viral spread into the alveolar spaces leading to reduced ALI. Although the β6 KO have morphologically normal lungs, they harbor constitutively activated lung CD11b+ alveolar macrophages (AM and elevated type I IFN signaling activity, which we traced to the loss of β6-activated transforming growth factor-β (TGF-β. Administration of exogenous TGF-β to β6 KO mice leads to reduced numbers of CD11b+ AMs, decreased type I IFN signaling activity and loss of the protective phenotype during influenza infection. Protection extended to other respiratory pathogens such as Sendai virus and bacterial pneumonia. Our studies demonstrate that the loss of one epithelial protein, αVβ6 integrin, can alter the lung microenvironment during both homeostasis and respiratory infection leading to reduced lung injury and improved survival.

  6. Mars Technology Program: Planetary Protection Technology Development

    Science.gov (United States)

    Lin, Ying

    2006-01-01

    This slide presentation reviews the development of Planetary Protection Technology in the Mars Technology Program. The goal of the program is to develop technologies that will enable NASA to build, launch, and operate a mission that has subsystems with different Planetary Protection (PP) classifications, specifically for operating a Category IVb-equivalent subsystem from a Category IVa platform. The IVa category of planetary protection requires bioburden reduction (i.e., no sterilization is required) The IVb category in addition to IVa requirements: (i.e., terminal sterilization of spacecraft is required). The differences between the categories are further reviewed.

  7. Hypoxemic Respiratory Failure from Acute Respiratory Distress Syndrome Secondary to Leptospirosis

    Directory of Open Access Journals (Sweden)

    Shannon M. Fernando

    2017-01-01

    Full Text Available Acute respiratory distress syndrome (ARDS, characterized by hypoxemic respiratory failure, is associated with a mortality of 30–50% and is precipitated by both direct and indirect pulmonary insults. Treatment is largely supportive, consisting of lung protective ventilation and thereby necessitating Intensive Care Unit (ICU admission. The most common precipitant is community-acquired bacterial pneumonia, but other putative pathogens include viruses and fungi. On rare occasions, ARDS can be secondary to tropical disease. Accordingly, a history should include travel to endemic regions. Leptospirosis is a zoonotic disease most common in the tropics and typically associated with mild pulmonary complications. We describe a case of a 25-year-old male with undiagnosed leptospirosis, presenting with fever and severe hypoxemic respiratory failure, returning from a Costa Rican holiday. There was no other organ failure. He was intubated and received lung protective ventilation. His condition improved after ampicillin and penicillin G were added empirically. This case illustrates the rare complication of ARDS from leptospirosis, the importance of taking a travel history, and the need for empiric therapy because of diagnostic delay.

  8. Standard Guide for Radiation Protection Program for Decommissioning Operations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide provides instruction to the individual charged with the responsibility for developing and implementing the radiation protection program for decommissioning operations. 1.2 This guide provides a basis for the user to develop radiation protection program documentation that will support both the radiological engineering and radiation safety aspects of the decommissioning project. 1.3 This guide presents a description of those elements that should be addressed in a specific radiation protection plan for each decommissioning project. The plan would, in turn, form the basis for development of the implementation procedures that execute the intent of the plan. 1.4 This guide applies to the development of radiation protection programs established to control exposures to radiation and radioactive materials associated with the decommissioning of nuclear facilities. The intent of this guide is to supplement existing radiation protection programs as they may pertain to decommissioning workers, members of...

  9. Effect of Menthol on Respiratory and Perceptual Responses to Exercise in Firefighter Protective Gear

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2015-09-01

    Full Text Available Impaired respiration reduces firefighters’ work capacity. This study evaluated the effect of menthol lozenge on respiratory and perceptual responses during exercise in a hot environment. Ten participants wearing firefighter protective gear performed two repeated exercise and rest trials in a counter-balanced order. Exercise consisted of two bouts of 20-min treadmill exercise at 60% of maximal oxygen uptake and one bout of 20-min stepping exercise at a wet bulb global temperature of 35°C. Participants either took 10-mg menthol or control lozenges prior to the beginning of each exercise bout. Respiratory gas exchange, heart rate, thermal sensation, and breathing comfort were continuously recorded. Menthol lozenges significantly increased pulmonary ventilation (menthol: 45.0±6.6 L•min-1 vs. control: 41.4±5.8 L•min-1 and menthol: 52.7±9.7 L•min-1 vs. control: 46.5±7.0 L•min-1, for the 1st and 2nd treadmill exercise, respectively and oxygen consumption (menthol: 26.7±2.0 ml•kg-1•min-1 vs. control: 25.2±2.3 ml•kg-1•min-1 and menthol: 28.8±2.3 ml•kg-1•min-1 vs. control: 26.9±1.9 ml•kg-1•min-1, for the 1st and 2nd treadmill exercise, respe¬cti¬ve¬ly (p0.05. The ventilatory equivalents though were not different throughout the exercise (p>0.05. Ratings of thermal sensation and breathing comfort were not different (p>0.05. It was concluded that menthol could alter breathing pattern and increase respiratory responses during strenuous exercise in the heat. There was no favorable effect of menthol on respiratory or perceptual responses under exercise-heat stress.

  10. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  11. Independent auto evaluation of an operative radiological protection program

    International Nuclear Information System (INIS)

    Medrano L, M.A.; Rodriguez C, C.C.; Linares R, D.; Zarate M, N.; Zempoalteca B, R.

    2006-01-01

    The program of operative radiological protection of a nuclear power plant consists of multiple procedures and associate tasks that have as purpose the radiological protection of the workers of the power station. It is for this reason that the constant evaluation of the one it programs it is an important tool in the identification of their weaknesses (and strengths), so they can be assisted appropriately. In this work the main elements of the program of independent auto evaluation of the program of operative radiological protection of the Laguna Verde Central that has been developed and implemented by the National Institute of Nuclear Research are described. (Author)

  12. Planetary protection in the framework of the Aurora exploration program

    Science.gov (United States)

    Kminek, G.

    The Aurora Exploration Program will give ESA new responsibilities in the field of planetary protection. Until now, ESA had only limited exposure to planetary protection from its own missions. With the proposed ExoMars and MSR missions, however, ESA will enter the realm of the highest planetary protection categories. As a consequence, the Aurora Exploration Program has initiated a number of activities in the field of planetary protection. The first and most important step was to establish a Planetary Protection Working Group (PPWG) that is advising the Exploration Program Advisory Committee (EPAC) on all matters concerning planetary protection. The main task of the PPWG is to provide recommendations regarding: Planetary protection for robotic missions to Mars; Planetary protection for a potential human mission to Mars; Review/evaluate standards & procedures for planetary protection; Identify research needs in the field of planetary protection. As a result of the PPWG deliberations, a number of activities have been initiated: Evaluation of the Microbial Diversity in SC Facilities; Working paper on legal issues of planetary protection and astrobiology; Feasibility study on a Mars Sample Return Containment Facility; Research activities on sterilization procedures; Training course on planetary protection (May, 2004); Workshop on sterilization techniques (fall 2004). In parallel to the PPWG, the Aurora Exploration Program has established an Ethical Working Group (EWG). This working group will address ethical issues related to astrobiology, planetary protection, and manned interplanetary missions. The recommendations of the working groups and the results of the R&D activities form the basis for defining planetary protection specification for Aurora mission studies, and for proposing modification and new inputs to the COSPAR planetary protection policy. Close cooperation and free exchange of relevant information with the NASA planetary protection program is strongly

  13. The Effect of a Designed Respiratory Care Program on the Incidence of Ventilator-Associated Pneumonia: A Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2016-01-01

    Full Text Available Introduction: Ventilator-associated pneumonia is a common complication of mechanical ventilation. This study aimed to evaluate the effect of designed respiratory care program on incidence of ventilator-associated pneumonia (VAP in the mechanically ventilated patient. Methods: In this clinical trial, 64 patients were selected among those who had undergone mechanical ventilation in the ICU of Al‑Zahra Hospital, Isfahan, Iran, using convenience sampling method. The subjects were randomly allocated to intervention and control groups. In the intervention group an upper respiratory care program and in the control group, routine cares were done. Modified Clinical Pulmonary Infection Questionnaire was completed before and on the third, fourth and fifth day of study. Data were analyzed by Chi-square and independent t-test through SPSS Ver.13. Results: The results of this study showed that until the third day of study, the incidence of VAP was similar in the both groups. However, on the fifth day of study, the incidence of VAP in the intervention group was significantly lower than control group. Conclusion: The results of this study showed that an upper respiratory care program reduced the incidence of VAP. Therefore, nurses are recommended to perform this program for prevention of VAP.

  14. Radiation protection technologist training and certification program

    International Nuclear Information System (INIS)

    1982-10-01

    The purpose of this program is to establish training requirements and methods for certifying the technical competence of Radiation Protection Technologists. This manual delineates general requirements as well as academic training, on-the-job training, area of facility training, and examination or evaluation requirements for Radiation Protection Trainees (Trainees), Junior Radiation Protection Technologists (JRPT), Radiation Protection Technologists (RPT), and Senior Radiation Protection Technologists (SRPT). This document also includes recertification requirements for SRPTs. The appendices include training course outlines, on-the-job training outlines, and training certification record forms

  15. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis

    Science.gov (United States)

    Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.

    2016-01-01

    Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions

  16. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis.

    Science.gov (United States)

    Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E

    2016-05-17

    Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95

  17. Establishing Correlates of Protection for Vaccine Development: Considerations for the Respiratory Syncytial Virus Vaccine Field.

    Science.gov (United States)

    Kulkarni, Prasad S; Hurwitz, Julia L; Simões, Eric A F; Piedra, Pedro A

    2018-03-01

    Correlates of protection (CoPs) can play a significant role in vaccine development by assisting the selection of vaccine candidates for clinical trials, supporting clinical trial design and implementation, and simplifying tests of vaccine modifications. Because of this important role in vaccine development, it is essential that CoPs be defined by well-designed immunogenicity and efficacy studies, with attention paid to benefits and limitations. The respiratory syncytial virus (RSV) field is unique in that a great deal of information about the humoral response is available from basic research and clinical studies. Polyclonal and monoclonal antibodies have been used routinely in the clinic to protect vulnerable infants from infection, providing a wealth of information about correlations between neutralizing antibodies and disease prevention. Considerations for the establishment of future CoPs to support RSV vaccine development in different populations are therefore discussed.

  18. Ebola virus disease: Effects of respiratory protection on healthcare workers

    Directory of Open Access Journals (Sweden)

    Hanan Mohammed Mohammed

    2015-07-01

    Full Text Available Ebola virus disease outbreak in West Africa sends an alarming message to all countries in the world, to increase the level of coordination and application of preventive measures globally to avoid a disastrous epidemic in the World, as the current situation in West Africa is critical especially after the World Health Organization increased the alarming level to an emergency in public health all over the world. Viral hemorrhagic fevers are important because they can readily spread within a hospital or mortuary setting, there is no effective cure or vaccine, they have a high mortality rate and they are difficult to recognize and diagnose rapidly. WHO has recommended respiratory protection for HCWs performing certain tasks such as aerosol-generating procedures, laboratory procedures, and autopsies. Particulate respirators are designed to help reduce the wearer’s exposure to certain airborne particles. The most effective way to block aerosolized particles is to use either a half-face or a full-face respirator. HCWs still need shoe covers, a full face respirator and latex or nitrile gloves to decrease the risk of Ebola virus contamination.

  19. Home discharge of technology-dependent children: evaluation of a respiratory-therapist driven family education program.

    Science.gov (United States)

    Tearl, Donna K; Hertzog, James H

    2007-02-01

    Initial hospital discharge to home of technology-dependent children requires extensive training and education of the family caregivers. Education of adult family members should promote positive interactions in a nonthreatening manner while facilitating the development of the knowledge and skills to competently and independently provide all aspects of the medical care. We utilize a training program for adult family members of children who have undergone tracheostomy to facilitate long-term mechanical ventilatory support and who are being prepared for their initial discharge from the hospital to home. A dedicated respiratory therapist family educator directs this program. Multiple teaching tools, activities, and training sessions, based on adult learning theory, are utilized to develop appropriate clinical skills to manage children with tracheostomies and the associated technological supports. We evaluated the effectiveness of our program by administering a written test to caregivers, at the start and the conclusion of their training. We also surveyed the caregivers about their satisfaction with the educational program and the respiratory therapist family educator's performance. We also surveyed employees of the durable medical equipment companies used by the families, regarding the caregivers' knowledge and competency in the home one month following discharge. Our program was associated with a statistically significant improvement in caregiver test performance, and the caregivers expressed a high degree of satisfaction with the program. The employees of the durable medical equipment companies perceived a high degree of knowledge and competence on the part of the home caregivers. Our training program appears to have a positive impact on the educational preparation of caregivers.

  20. Educational technology integration and distance learning in respiratory care: practices and attitudes.

    Science.gov (United States)

    Hopper, Keith B; Johns, Carol L

    2007-11-01

    Educational technologies have had an important role in respiratory care. Distance learning via postal correspondence has been used extensively in respiratory care, and Internet-based distance learning is now used in the training of respiratory therapists (RTs), clinical continuing education, and in baccalaureate degree and higher programs for RTs and educators. To describe the current scope of respiratory care educational technology integration, including distance learning. To investigate online research potential in respiratory care. A probabilistic online survey of United States respiratory care program directors was conducted on educational technology practices and attitudes, including distance learning. A parallel exploratory study of United States respiratory care managers was conducted. One-hundred seventy-seven (53%) program directors participated. One-hundred twenty-eight respiratory care managers participated. For instructional purposes, the respiratory care programs heavily use office-productivity software, the Internet, e-mail, and commercial respiratory care content-based computer-based instruction. The programs use, or would use, online resources provided by text publishers, but there is a paucity. Many program directors reported that their faculty use personal digital assistants (PDAs), often in instructional roles. 74.6% of the programs offer no fully online courses, but 61.0% reported at least one course delivered partially online. The managers considered continuing education via online technologies appropriate, but one third reported that they have not/will not hire RTs trained via distance learning. Neither group considered fully online courses a good match for RT training, nor did they consider training via distance learning of comparable quality to on-campus programs. Both groups rated baccalaureate and higher degrees via distance learning higher if the program included face-to-face instruction. Online distance-learning participatory experience

  1. Nevada National Security Site Radiation Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-04-30

    Title 10 Code of Federal Regulations (CFR) Part 835, “Occupational Radiation Protection,” establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada National Security Site (NNSS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operations, and environmental restoration off-site projects. This RPP section consists of general statements that are applicable to the NNSS as a whole. The RPP also includes a series of appendices which provide supporting detail for the associated NNSS Tennant Organizations (TOs). Appendix H, “Compliance Demonstration Table,” contains a cross-walk for the implementation of 10 CFR 835 requirements. This RPP does not contain any exemptions from the established 10 CFR 835 requirements. The RSPC and TOs are fully compliant with 10 CFR 835 and no additional funding is required in order to meet RPP commitments. No new programs or activities are needed to meet 10 CFR 835 requirements and there are no anticipated impacts to programs or activities that are not included in the RPP. There are no known constraints to implementing the RPP. No guides or technical standards are adopted in this RPP as a means to meet the requirements of 10 CFR 835.

  2. Workplace safety and health programs, practices, and conditions in auto collision repair businesses.

    Science.gov (United States)

    Brosseau, L M; Bejan, A; Parker, D L; Skan, M; Xi, M

    2014-01-01

    This article describes the results of a pre-intervention safety assessment conducted in 49 auto collision repair businesses and owners' commitments to specific improvements. A 92-item standardized audit tool employed interviews, record reviews, and observations to assess safety and health programs, training, and workplace conditions. Owners were asked to improve at least one-third of incorrect, deficient, or missing (not in compliance with regulations or not meeting best practice) items, of which a majority were critical or highly important for ensuring workplace safety. Two-thirds of all items were present, with the highest fraction related to electrical safety, machine safety, and lockout/tagout. One-half of shops did not have written safety programs and had not conducted recent training. Many had deficiencies in respiratory protection programs and practices. Thirteen businesses with a current or past relationship with a safety consultant had a significantly higher fraction of correct items, in particular related to safety programs, up-to-date training, paint booth and mixing room conditions, electrical safety, and respiratory protection. Owners selected an average of 58% of recommended improvements; they were most likely to select items related to employee Right-to-Know training, emergency exits, fire extinguishers, and respiratory protection. They were least likely to say they would improve written safety programs, stop routine spraying outside the booth, or provide adequate fire protection for spray areas outside the booth. These baseline results suggest that it may be possible to bring about workplace improvements using targeted assistance from occupational health and safety professionals.

  3. CEC radiation protection research and training program

    International Nuclear Information System (INIS)

    Gerber, G.B.

    1991-01-01

    The Radiation Protection Program (RPP), initiated as a consequence of the Euratom Treaty aims to promote: scientific knowledge to evaluate possible risks from low doses of natural, medical and man-made radiation; development of methods to assess radiological risks; incentive and support for cooperation between scientists of Member States; expertise in radiation protection by training scientists and the scientific basis for continual updating of the 'Basic Safety Standards', and the evolution of radiation protection concepts and practices. 3 refs

  4. The protection system to Brazilian Nuclear Program

    International Nuclear Information System (INIS)

    Andreuzza, Mario Giussepp Santezzi Bertottelli

    1997-01-01

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author)

  5. Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress sindrome.

    Science.gov (United States)

    Fanelli, Vito; Ranieri, Marco V; Mancebo, Jordi; Moerer, Onnen; Quintel, Michael; Morley, Scott; Moran, Indalecio; Parrilla, Francisco; Costamagna, Andrea; Gaudiosi, Marco; Combes, Alain

    2016-02-10

    Mechanical ventilation with a tidal volume (VT) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (Pplat) lower than 30 cmH2O, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low VT combined with extracorporeal carbon dioxide removal (ECCO2R). In fifteen patients with moderate ARDS, VT was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure--(Pplat) between 23 and 25 cmH2O. Low-flow ECCO2R was initiated when respiratory acidosis developed (pH 60 mmHg). Ventilation parameters (VT, respiratory rate, PEEP), respiratory compliance (CRS), driving pressure (DeltaP = VT/CRS), arterial blood gases, and ECCO2R system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCO2R when PaO2/FiO2 was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCO2R were also collected. During the 2 h run in phase, VT reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH protective mechanical ventilation strategy in patients with moderate ARDS.

  6. Effects on Pulmonary Vascular Mechanics of Two Different Lung-Protective Ventilation Strategies in an Experimental Model of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Santos, Arnoldo; Gomez-Peñalver, Eva; Monge-Garcia, M Ignacio; Retamal, Jaime; Borges, João Batista; Tusman, Gerardo; Hedenstierna, Goran; Larsson, Anders; Suarez-Sipmann, Fernando

    2017-11-01

    To compare the effects of two lung-protective ventilation strategies on pulmonary vascular mechanics in early acute respiratory distress syndrome. Experimental study. University animal research laboratory. Twelve pigs (30.8 ± 2.5 kg). Acute respiratory distress syndrome was induced by repeated lung lavages and injurious mechanical ventilation. Thereafter, animals were randomized to 4 hours ventilation according to the Acute Respiratory Distress Syndrome Network protocol or to an open lung approach strategy. Pressure and flow sensors placed at the pulmonary artery trunk allowed continuous assessment of pulmonary artery resistance, effective elastance, compliance, and reflected pressure waves. Respiratory mechanics and gas exchange data were collected. Acute respiratory distress syndrome led to pulmonary vascular mechanics deterioration. Four hours after randomization, pulmonary vascular mechanics was similar in Acute Respiratory Distress Syndrome Network and open lung approach: resistance (578 ± 252 vs 626 ± 153 dyn.s/cm; p = 0.714), effective elastance, (0.63 ± 0.22 vs 0.58 ± 0.17 mm Hg/mL; p = 0.710), compliance (1.19 ± 0.8 vs 1.50 ± 0.27 mL/mm Hg; p = 0.437), and reflection index (0.36 ± 0.04 vs 0.34 ± 0.09; p = 0.680). Open lung approach as compared to Acute Respiratory Distress Syndrome Network was associated with improved dynamic respiratory compliance (17.3 ± 2.6 vs 10.5 ± 1.3 mL/cm H2O; p mechanics similarly. The use of higher positive end-expiratory pressures in the open lung approach strategy did not worsen pulmonary vascular mechanics, improved lung mechanics, and gas exchange but at the expense of a lower cardiac index.

  7. Sleep technologists educational needs assessment: a survey of polysomnography, electroneurodiagnostic technology, and respiratory therapy education program directors.

    Science.gov (United States)

    Wells, Mary Ellen; Vaughn, Bradley V

    2013-10-15

    In this study, we assessed the community and educational needs for sleep technologists by surveying program directors of nationally accredited polysomnography, electroneurodiagnostic technology, and respiratory care educational programs. Currently, little is known about our educational capacity and the need for advanced degrees for sleep medicine technical support. A questionnaire was developed about current and future community and educational needs for sleep technologists. The questionnaire was sent to directors of CAAHEP-accredited polysomnography and electroneurodiagnostic technology programs (associate degree and certificate programs), and directors of CoARC-accredited respiratory therapy associate degree and bachelor degree programs (n = 358). Qualitative and quantitative data were collected via an internet survey tool. Data analysis was conducted with the IBM SPSS statistical package and included calculating means and standard deviations of the frequency of responses. Qualitative data was analyzed and classified based on emerging themes. One hundred seven of 408 program directors completed the survey. Seventy-four percent agreed that demand for qualified sleep technologists will increase, yet 50% of those surveyed believe there are not enough educational programs to meet the demand. Seventy-eight percent of those surveyed agreed that the educational requirements for sleep technologists will soon increase; 79% of those surveyed believe sleep centers have a need for technologists with advanced training or specialization. Our study shows educators of associate and certificate degree programs believe there is a need for a bachelor's degree in sleep science and technology.

  8. Program for radiation protection of the patient (Argentina)

    International Nuclear Information System (INIS)

    Touzet, Rodolfo E.; Perez, Maria del R.; Alfredo Buzzi; Andisco, Daniel

    2006-01-01

    After an initial period of conviction for installing an active discussion on radiation protection of patients inside the medical community, there were organized 'working groups' in radiodiagnosis, radiotherapy, nuclear medicine and on radiation protection of pregnant women. These groups began systematical activities, which received a strong institutional support of the Argentine Society of Radiology, toward the implementation of a 'Program of RPP' that is being put nowadays into practice. This program has three aims and a series of targets to be fulfilled in successive stages: basic aims and short term targets: 1) To guarantee the justification: first goal: development of the 'Prescription Guide' (achieved); 2) To optimize the radioprotection: first goal: Development of a 'Manual of Procedures' (achieved); 3) To prevent potential exposures: first goal: Design of a 'Basic quality system' in Health (achieved). The effective participation of the professional's and technician's associations in the development of the program of radiological protection of the patient is a key aspect for the success. (author) [es

  9. The depiction of protective eyewear use in popular television programs.

    Science.gov (United States)

    Glazier, Robert; Slade, Martin; Mayer, Hylton

    2011-04-01

    Media portrayal of health related activities may influence health related behaviors in adult and pediatric populations. This study characterizes the depiction of protective eyewear use in the scripted television programs most viewed by the age group that sustains the largest proportion of eye injuries. Viewership ratings data were acquired to assemble a list of the 24 most-watched scripted network broadcast programs for the 13-year-old to 45-year-old age group. The six highest average viewership programs that met the exclusion criteria were selected for analysis. Review of 30 episodes revealed a total of 258 exposure scenes in which an individual was engaged in an activity requiring eye protection (mean, 8.3 exposure scenes per episode; median, 5 exposure scenes per episode). Overall, 66 (26%) of exposure scenes depicted the use of any eye protection, while only 32 (12%) of exposure scenes depicted the use of adequate eye protection. No incidences of eye injuries or infectious exposures were depicted within the exposure scenes in the study set. The depiction of adequate protective eyewear use during eye-risk activities is rare in network scripted broadcast programs. Healthcare professionals and health advocacy groups should continue to work to improve public education about eye injury risks and prevention; these efforts could include working with the television industry to improve the accuracy of the depiction of eye injuries and the proper protective eyewear used for prevention of injuries in scripted programming. Future studies are needed to examine the relationship between media depiction of eye protection use and viewer compliance rates.

  10. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Science.gov (United States)

    2010-10-01

    ... mist respirators designed for respiratory protection against fumes of various metals having an air... HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist....1141 Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

  11. Effect of lung-protective ventilation-induced respiratory acidosis on the duration of neuromuscular blockade by rocuronium.

    Science.gov (United States)

    Taguchi, Shinya; Ono, Kazumi; Hidaka, Hidekuni; Koyama, Yusuke

    2016-12-01

    The purpose of this study was to elucidate whether lung-protective ventilation-induced respiratory acidosis increased the duration of neuromuscular blockade by rocuronium. A total of 72 patients were enrolled. After the induction of general anesthesia, rocuronium 0.6 mg/kg real body weight was administered. Tidal volume and positive end-expiratory pressure were randomly assigned as either 10 ml/kg predicted body weight and 0 cmH 2 O (group S) or 6 ml/kg and 5 cmH 2 O (group L), respectively. Respiratory rate was started at 10/min. Neuromuscular blockade was monitored by acceleromyography at the adductor pollicis with train-of-four stimulation. The time from the initial bolus injection of rocuronium to first recovery of the first twitch was defined as DUR1. Immediately, rocuronium 0.15 mg/kg was administered. The time from first recovery of the first twitch to second recovery of the first twitch was defined as DUR2. We also measured arterial pH (pH1 and pH2, respectively). Data from 66 patients (33 each in groups L and S) were eventually available. pH1 and pH2 were significantly lower in group L compared with group S [pH1: 7.308 (7.288-7.334) vs. 7.439 (7.423-7.466); p respiratory acidosis increased the duration of neuromuscular blockade by rocuronium.

  12. 76 FR 5186 - National Protection and Programs Directorate; Agency Information Collection Activities; Office of...

    Science.gov (United States)

    2011-01-28

    ... DEPARTMENT OF HOMELAND SECURITY [Docket No. DHS-2010-0084] National Protection and Programs... Protection Stakeholder Input Project--Generic Clearance AGENCY: National Protection and Programs Directorate.... SUMMARY: The Department of Homeland Security (DHS), National Protection and Programs Directorate (NPPD...

  13. Nevada Test Site Radiation Protection Program - Revision 1

    International Nuclear Information System (INIS)

    Nevada Test Site Radiological Control Managers' Council

    2008-01-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material

  14. Nevada Test Site Radiation Protection Program - Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council

    2008-06-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material.

  15. Quality assurance programs from laboratories offering radiological protection services

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Prendes Alonso, M.; Jova Sed, L.; Morales Monzon, J.A.

    1998-01-01

    The implementation of an adequate program for quality assurance in institutions servicing radiological protection programs will become an additional tool to achieve security targets included in that program. All scientific and technical services offered by CPHR employ quality assurance systems

  16. Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System® to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Akkanti, Bindu; Rajagopal, Keshava; Patel, Kirti P; Aravind, Sangeeta; Nunez-Centanu, Emmanuel; Hussain, Rahat; Shabari, Farshad Raissi; Hofstetter, Wayne L; Vaporciyan, Ara A; Banjac, Igor S; Kar, Biswajit; Gregoric, Igor D; Loyalka, Pranav

    2017-06-01

    Extracorporeal carbon dioxide removal (ECCO 2 R) permits reductions in alveolar ventilation requirements that the lungs would otherwise have to provide. This concept was applied to a case of hypercapnia refractory to high-level invasive mechanical ventilator support. We present a case of an 18-year-old man who developed post-pneumonectomy acute respiratory distress syndrome (ARDS) after resection of a mediastinal germ cell tumor involving the left lung hilum. Hypercapnia and hypoxemia persisted despite ventilator support even at traumatic levels. ECCO 2 R using a miniaturized system was instituted and provided effective carbon dioxide elimination. This facilitated establishment of lung-protective ventilator settings and lung function recovery. Extracorporeal lung support increasingly is being applied to treat ARDS. However, conventional extracorporeal membrane oxygenation (ECMO) generally involves using large cannulae capable of carrying high flow rates. A subset of patients with ARDS has mixed hypercapnia and hypoxemia despite high-level ventilator support. In the absence of profound hypoxemia, ECCO 2 R may be used to reduce ventilator support requirements to lung-protective levels, while avoiding risks associated with conventional ECMO.

  17. Dose-Dependent Protective Effect of Inhalational Anesthetics Against Postoperative Respiratory Complications

    DEFF Research Database (Denmark)

    Grabitz, Stephanie D; Farhan, Hassan N; Ruscic, Katarina J

    2017-01-01

    OBJECTIVES: Inhalational anesthetics are bronchodilators with immunomodulatory effects. We sought to determine the effect of inhalational anesthetic dose on risk of severe postoperative respiratory complications. DESIGN: Prospective analysis of data on file in surgical cases between January 2007...... with endotracheal intubation. INTERVENTIONS: Median effective dose equivalent of inhalational anesthetics during surgery (derived from mean end-tidal inhalational anesthetic concentrations). MEASUREMENTS AND MAIN RESULTS: Postoperative respiratory complications occurred in 6,979 of 124,497 cases (5.61%). High...... inhalational anesthetic dose of 1.20 (1.13-1.30) (median [interquartile range])-fold median effective dose equivalent versus 0.57 (0.45-0.64)-fold median effective dose equivalent was associated with lower odds of postoperative respiratory complications (odds ratio, 0.59; 95% CI, 0.53-0.65; p

  18. Physical protection evaluation methodology program development and application

    International Nuclear Information System (INIS)

    Seo, Janghoon; Yoo, Hosik

    2015-01-01

    It is essential to develop a reliable physical protection evaluation methodology for applying physical protection concept to the design stage. The methodology can be used to assess weak points and improve performance not only for the design stage but also for nuclear facilities in operation. Analyzing physical protection property of nuclear facilities is not a trivial work since there are many interconnected factors affecting overall performance. Therefore several international projects have been organized to develop a systematic physical protection evaluation methodology. INPRO (The International Project on Innovative Nuclear Reactors and Fuel Cycles) and GIF PRPP (Generation IV International Forum Proliferation Resistance and Physical Protection) methodology are among the most well-known evaluation methodologies. INPRO adopts a checklist type of questionnaire and has a strong point in analyzing overall characteristic of facilities in a qualitative way. COMPRE program has been developed to help general users apply COMPRE methodology to nuclear facilities. In this work, COMPRE program development and a case study of the hypothetical nuclear facility are presented. The development of COMPRE program and a case study for hypothetic facility is presented in this work. The case study shows that COMPRE PP methodology can be a useful tool to assess the overall physical protection performance of nuclear facilities. To obtain meaningful results from COMPRE PP methodology, detailed information and comprehensive analysis are required. Especially, it is not trivial to calculate reliable values for PPSE (Physical Protection System Effectiveness) and C (Consequence), while it is relatively straightforward to evaluate LI (Legislative and Institutional framework), MC (Material Control) and HR (Human Resources). To obtain a reliable PPSE value, comprehensive information about physical protection system, vital area analysis and realistic threat scenario assessment are required. Like

  19. Physical protection evaluation methodology program development and application

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Janghoon; Yoo, Hosik [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of)

    2015-10-15

    It is essential to develop a reliable physical protection evaluation methodology for applying physical protection concept to the design stage. The methodology can be used to assess weak points and improve performance not only for the design stage but also for nuclear facilities in operation. Analyzing physical protection property of nuclear facilities is not a trivial work since there are many interconnected factors affecting overall performance. Therefore several international projects have been organized to develop a systematic physical protection evaluation methodology. INPRO (The International Project on Innovative Nuclear Reactors and Fuel Cycles) and GIF PRPP (Generation IV International Forum Proliferation Resistance and Physical Protection) methodology are among the most well-known evaluation methodologies. INPRO adopts a checklist type of questionnaire and has a strong point in analyzing overall characteristic of facilities in a qualitative way. COMPRE program has been developed to help general users apply COMPRE methodology to nuclear facilities. In this work, COMPRE program development and a case study of the hypothetical nuclear facility are presented. The development of COMPRE program and a case study for hypothetic facility is presented in this work. The case study shows that COMPRE PP methodology can be a useful tool to assess the overall physical protection performance of nuclear facilities. To obtain meaningful results from COMPRE PP methodology, detailed information and comprehensive analysis are required. Especially, it is not trivial to calculate reliable values for PPSE (Physical Protection System Effectiveness) and C (Consequence), while it is relatively straightforward to evaluate LI (Legislative and Institutional framework), MC (Material Control) and HR (Human Resources). To obtain a reliable PPSE value, comprehensive information about physical protection system, vital area analysis and realistic threat scenario assessment are required. Like

  20. Biodegradable nanoparticle-entrapped vaccine induces cross-protective immune response against a virulent heterologous respiratory viral infection in pigs.

    Directory of Open Access Journals (Sweden)

    Varun Dwivedi

    Full Text Available Biodegradable nanoparticle-based vaccine development research is unexplored in large animals and humans. In this study, we illustrated the efficacy of nanoparticle-entrapped UV-killed virus vaccine against an economically important respiratory viral disease of pigs called porcine reproductive and respiratory syndrome virus (PRRSV. We entrapped PLGA [poly (lactide-co-glycolides] nanoparticles with killed PRRSV antigens (Nano-KAg and detected its phagocytosis by pig alveolar macrophages. Single doses of Nano-KAg vaccine administered intranasally to pigs upregulated innate and PRRSV specific adaptive responses. In a virulent heterologous PRRSV challenge study, Nano-KAg vaccine significantly reduced the lung pathology and viremia, and the viral load in the lungs. Immunologically, enhanced innate and adaptive immune cell population and associated cytokines with decreased secretion of immunosuppressive mediators were observed at both mucosal sites and blood. In summary, we demonstrated the benefits of intranasal delivery of nanoparticle-based viral vaccine in eliciting cross-protective immune response in pigs, a potential large animal model.

  1. Effect of a Health Care System Respiratory Fluoroquinolone Restriction Program To Alter Utilization and Impact Rates of Clostridium difficile Infection.

    Science.gov (United States)

    Shea, Katherine M; Hobbs, Athena L V; Jaso, Theresa C; Bissett, Jack D; Cruz, Christopher M; Douglass, Elizabeth T; Garey, Kevin W

    2017-06-01

    Fluoroquinolones are one of the most commonly prescribed antibiotic classes in the United States despite their association with adverse consequences, including Clostridium difficile infection (CDI). We sought to evaluate the impact of a health care system antimicrobial stewardship-initiated respiratory fluoroquinolone restriction program on utilization, appropriateness of quinolone-based therapy based on institutional guidelines, and CDI rates. After implementation, respiratory fluoroquinolone utilization decreased from a monthly mean and standard deviation (SD) of 41.0 (SD = 4.4) days of therapy (DOT) per 1,000 patient days (PD) preintervention to 21.5 (SD = 6.4) DOT/1,000 PD and 4.8 (SD = 3.6) DOT/1,000 PD posteducation and postrestriction, respectively. Using segmented regression analysis, both education (14.5 DOT/1,000 PD per month decrease; P = 0.023) and restriction (24.5 DOT/1,000 PD per month decrease; P cost of moxifloxacin, the formulary respiratory fluoroquinolone, was observed postrestriction compared to preintervention within the health care system ($123,882 versus $12,273; P = 0.002). Implementation of a stewardship-initiated respiratory fluoroquinolone restriction program can increase appropriate use while reducing overall utilization, acquisition cost, and CDI rates within a health care system. Copyright © 2017 American Society for Microbiology.

  2. Child Protection Program Implementations in Sport Management

    Directory of Open Access Journals (Sweden)

    Özgün PARASIZ

    2015-07-01

    Full Text Available The protection and provision of the welfare of children who are in a vulnerable condition to all kinds of risk in the modern world in every field they actively take part in is acknowledged as one of the most important social responsibilites of states in this day and age. In the fight against this problem, especially developed countries promote chi ld protection policies and implement them in every sport field children take active part in. The aim of this study is to examine in which dimensions child protection system, defined as the provision of the child’s safety in all aspects including physical, social, emotional, economic, cultural, ethnic, moral, religious and political on a legal basis and in practice, is implemented within the sport systems of England and to identify the policies of sports organizations. In the study, scanning method based o n the literature was used. Research data was obtained by examining the related sources on the subject in various international libraries, journals, books and sports organizations. According to the information obtained in the study, child protection progra ms were identified to be a legal obligation for independent sports organizations responsible for the management of the sport (such as Federations, Olympic committees, sport clubs. The fundamental purpose of child protection programs is to diminish the ris k of all kinds of (sexual, physical and emotional child abuse. Sports organization establish child protection systems within their governing structure and work in coordination with the related units of clubs, federations and central administrations. Moreo ver, by providing special trainings to administrators and coaches, the stipulation of obtaining a special document for coaches who shall work with sportsmen under the age of 18 has been laid down. Special regulations and educational programs for sport fede rations have been prepared intended for the functioning of child protection system in

  3. Human milk 90K (Mac-2 BP): possible protective effects against acute respiratory infections.

    Science.gov (United States)

    Fornarini, B; Iacobelli, S; Tinari, N; Natoli, C; De Martino, M; Sabatino, G

    1999-01-01

    Eighty-six children fed human milk were followed prospectively from birth to 12 months of age to assess the effect of milk 90K, a secreted glycoprotein with immune-stimulatory properties, on development of acute respiratory infections (ARI). The level of human milk 90K was inversely related to episodes of ARI (r = - 0.34; P = 0.001). The average 90K level in human milk fed to children who did not develop ARI was significantly higher than in milk fed to children in whom infection occurred on multiple occasions (156.6 +/- 144.8 microg/ml versus 70.9 +/- 92.3 microg/ml; P = 0.001). These data suggest that the protective effects of human milk against ARI may be due in part to immune maturation effects by secreted 90K.

  4. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2002-09-24

    U.S. Department of Energy (DOE) Order 5400.1, General Environmental Protection Program, requires each DOE site to prepare a Groundwater Protection Management Program Plan. This document fulfills the requirement for the Waste Isolation Pilot Plant (WIPP). This document was prepared by the Hydrology Section of the Westinghouse TRU Solutions LLC (WTS) Environmental Compliance Department, and it is the responsibility of this group to review the plan annually and update it every three years. This document is not, nor is it intended to be, an implementing document that sets forth specific details on carrying out field projects or operational policy. Rather, it is intended to give the reader insight to the groundwater protection philosophy at WIPP.

  5. Review of economic evaluations of mask and respirator use for protection against respiratory infection transmission.

    Science.gov (United States)

    Mukerji, Shohini; MacIntyre, C Raina; Newall, Anthony T

    2015-10-13

    There has been increasing debate surrounding mask and respirator interventions to control respiratory infection transmission in both healthcare and community settings. As decision makers are considering the recommendations they should evaluate how to provide the most efficient protection strategies with minimum costs. The aim of this review is to identify and evaluate the existing economic evaluation literature in this area and to offer advice on how future evaluations on this topic should be conducted. We searched the Scopus database for all literature on economic evaluation of mask or respirator use to control respiratory infection transmission. Reference lists from the identified studies were also manually searched. Seven studies met our inclusion criteria from the initial 806 studies identified by the search strategy and our manual search. Five studies considered interventions for seasonal and/or pandemic influenza, with one also considering SARS (Severe Acute Respiratory Syndrome). The other two studies focussed on tuberculosis transmission control interventions. The settings and methodologies of the studies varied greatly. No low-middle income settings were identified. Only one of the reviewed studies cited clinical evidence to inform their mask/respirator intervention effectiveness parameters. Mask and respirator interventions were generally reported by the study authors to be cost saving or cost-effective when compared to no intervention or other control measures, however the evaluations had important limitations. Given the large cost differential between masks and respirators, there is a need for more comprehensive economic evaluations to compare the relative costs and benefits of these interventions in situations and settings where alternative options are potentially applicable. There are at present insufficient well conducted cost-effectiveness studies to inform decision-makers on the value for money of alternative mask/respirator options.

  6. Association Between Use of Lung-Protective Ventilation With Lower Tidal Volumes and Clinical Outcomes Among Patients Without Acute Respiratory Distress Syndrome A Meta-analysis

    NARCIS (Netherlands)

    Serpa Neto, Ary; Cardoso, Sérgio Oliveira; Manetta, José Antônio; Pereira, Victor Galvão Moura; Espósito, Daniel Crepaldi; Pasqualucci, Manoela de Oliveira Prado; Damasceno, Maria Cecília Toledo; Schultz, Marcus J.

    2012-01-01

    Context Lung-protective mechanical ventilation with the use of lower tidal volumes has been found to improve outcomes of patients with acute respiratory distress syndrome (ARDS). It has been suggested that use of lower tidal volumes also benefits patients who do not have ARDS. Objective To determine

  7. Climate change and respiratory health.

    Science.gov (United States)

    Gerardi, Daniel A; Kellerman, Roy A

    2014-10-01

    To discuss the nature of climate change and both its immediate and long-term effects on human respiratory health. This review is based on information from a presentation of the American College of Chest Physicians course on Occupational and Environmental Lung Disease held in Toronto, Canada, June 2013. It is supplemented by a PubMed search for climate change, global warming, respiratory tract diseases, and respiratory health. It is also supplemented by a search of Web sites including the Environmental Protection Agency, National Oceanic and Atmospheric Administration, World Meteorological Association, National Snow and Ice Data Center, Carbon Dioxide Information Analysis Center, Inter-Governmental Panel on Climate Change, and the World Health Organization. Health effects of climate change include an increase in the prevalence of certain respiratory diseases, exacerbations of chronic lung disease, premature mortality, allergic responses, and declines in lung function. Climate change, mediated by greenhouse gases, causes adverse health effects to the most vulnerable patient populations-the elderly, children, and those in distressed socioeconomic strata.

  8. The CD8 T Cell Response to Respiratory Virus Infections.

    Science.gov (United States)

    Schmidt, Megan E; Varga, Steven M

    2018-01-01

    Humans are highly susceptible to infection with respiratory viruses including respiratory syncytial virus (RSV), influenza virus, human metapneumovirus, rhinovirus, coronavirus, and parainfluenza virus. While some viruses simply cause symptoms of the common cold, many respiratory viruses induce severe bronchiolitis, pneumonia, and even death following infection. Despite the immense clinical burden, the majority of the most common pulmonary viruses lack long-lasting efficacious vaccines. Nearly all current vaccination strategies are designed to elicit broadly neutralizing antibodies, which prevent severe disease following a subsequent infection. However, the mucosal antibody response to many respiratory viruses is not long-lasting and declines with age. CD8 T cells are critical for mediating clearance following many acute viral infections in the lung. In addition, memory CD8 T cells are capable of providing protection against secondary infections. Therefore, the combined induction of virus-specific CD8 T cells and antibodies may provide optimal protective immunity. Herein, we review the current literature on CD8 T cell responses induced by respiratory virus infections. Additionally, we explore how this knowledge could be utilized in the development of future vaccines against respiratory viruses, with a special emphasis on RSV vaccination.

  9. Operational experience using the OSTR flip fuel self-protection program

    International Nuclear Information System (INIS)

    Dodd, B.; Ringle, J.C.; Anderson, T.V.; Johnson, A.G.

    1982-01-01

    Recent changes in NRC Physical Security regulations make it highly desirable for a small number of TRIGA research reactor establishments to maintain each of the fuel elements in their reactor core above the self-protection dose rate criterion. OSTR operations personnel have written a computer program (SPOOF) which calculates the exposure rate (in Rhr -1 ) from an irradiated fuel element at 3 feet in air using the actual operating history of the reactor. The purpose of this current paper is to describe the operational experience gained over the last year and a half while using the SPOOF computer program, and while performing the quarterly dose rate measurements needed to confirm the continuing accuracy of the program, and, most importantly, the self-protection status of the OSTR fuel. The computer program in association with the quarterly dose rate measurements have been accepted by the NRC, and allow the OSTR to take credit for self-protecting FLIP fuel under the current physical security regulations

  10. Program of radiation protection of patients (Argentina)

    International Nuclear Information System (INIS)

    Touzet, Rodolfo E.; Buzzi, Alfredo; Rojas, Roberto; Andisco Daniel

    2008-01-01

    After an initial period of conviction for installing an active discussion on Radiation Protection of Patients inside the medical community, there were organized 'working groups' in Radiodiagnosis, Radiotherapy, Nuclear Medicine and on radiation protection of pregnant women. These groups began systematical activities, which received a strong institutional support of the Argentine Society of Radiology, toward the implementation of a 'Program of RPP' that is being put nowadays into practice. The rapid advances which are present in medicine today, both in equipment and work protocol, determine that 'norms and regulations never arrive on time' which is why it is paramount that health services have 'systems of dynamic quality' and 'continual improvement' that can be adapted quickly to changes. This program has 6 principal aims and a series of targets to be fulfilled in successive stages: Basic aims and short term targets: 1) To guarantee the Justification. First goal: Development of the 'Prescription Guide' (achieved); 2) To optimize the radioprotection: First goal: Development of a 'Manual of Procedures' (In process); 3) To prevent potential exposures. First goal: Design of a 'Basic Quality System' in Health (achieved); 4) To achieve a qualification of the professionals by means of a process of certification and re-certification (In process); 5) To spread PRP's criteria by means of chats, meetings and the use of the media and graphical means. (Partially fulfilled); 6) To establish criteria for the protection of patient and operators in Interventional Radiology by creating a referral service. Strategies to cope with different interests within society are described. Main problems, failures and difficulties are also described. The effective participation of the professional and technicians' associations in the development of the program for radiation protection of the patient is a key aspect for the success of the whole national programme. (author)

  11. 59th Medical Wing Protection of Vulnerable Populations: Ombudsman Program

    Science.gov (United States)

    2018-04-20

    REPORT TYPE 20/04/2018 poster 4. TITLE AND SUBTITLE 59th Medical Wing Protection of Vulnerable Populations: Ombudsman Program 6. AUTHOR(S...13. SUPPLEMENTARY NOTES 2018 Annual AAHRPP Conference April 20-22, 2018 Denver, CO 14. ABSTRACT 1S. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF...59th Medical Wing Protection of Vulnerable Populations: Ombudsman Program Wayne DeutschDDS1, MPH, Michele Tavish LYN, PMP, CCRC 1 Brenda

  12. Acute Responses to Diuretic Therapy in Extremely Low Gestational Age Newborns: Results from the Prematurity and Respiratory Outcomes Program Cohort Study.

    Science.gov (United States)

    Blaisdell, Carol J; Troendle, James; Zajicek, Anne

    2018-06-01

    To determine if daily respiratory status improved more in extremely low gestational age (GA) premature infants after diuretic exposure compared with those not exposed in modern neonatal intensive care units. The Prematurity and Respiratory Outcomes Program (PROP) was a multicenter observational cohort study of 835 extremely premature infants, GAs of 23 0/7 -28 6/7 weeks, enrolled in the first week of life from 13 US tertiary neonatal intensive care units. We analyzed the PROP study daily medication and respiratory support records of infants ≤34 weeks postmenstrual age. We determined whether there was a temporal association between the administration of diuretics and an acute change in respiratory status in premature infants in the neonatal intensive care unit, using an ordered categorical ranking of respiratory status. Infants in the diuretic exposed group of PROP were of lower mean GA and lower mean birth weight (P respiratory status before receiving diuretics) that the exposed infants were on a higher level of respiratory support was significantly greater (OR, >1) for each day after the initial day of diuretic exposure. Our analysis did not support the ability of diuretics to substantially improve the extremely premature infant's respiratory status. Further study of both safety and efficacy of diuretics in this setting are warranted. Clinicaltrials.gov: NCT01435187. Published by Elsevier Inc.

  13. Specific features of using programmed hardware in emergency protection systems of NPP

    International Nuclear Information System (INIS)

    Konoplev, N.P.; Pogorelov, I.V.; Kirsanov, A.V.

    2005-01-01

    The specific features of using the microprocessor-based technical means and programmed logic integrated circuits (PLIC) in WWER reactor protection systems are considered. The basic causes of occurring the failures in programmed technical means are analyzed. The features of using PLIC in reactor protection systems are discussed. The methods permitting to decrease the probability occurring the common mode failure of programmed technical means are proposed. It is concluded that at creating of reactor protection systems with the use of microprocessors and PLIC it is necessary to apply the principle of the functional diversity [ru

  14. An evaluation of the respiratory health status of automotive spray ...

    African Journals Online (AJOL)

    administered standardised respiratory health questionnaire and a cross-shift .... safety matters;. (il) a general questionnaire on the employee's knowledge of ... Occupational Safety and Health.' ... All establishments had provided some form of respiratory protection .... asthma,13 the effects of HOl exposure are not as clearly.

  15. A Quasi-Experimental, Before-After Trial Examining the Impact of an Emergency Department Mechanical Ventilator Protocol on Clinical Outcomes and Lung-Protective Ventilation in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Fuller, Brian M; Ferguson, Ian T; Mohr, Nicholas M; Drewry, Anne M; Palmer, Christopher; Wessman, Brian T; Ablordeppey, Enyo; Keeperman, Jacob; Stephens, Robert J; Briscoe, Cristopher C; Kolomiets, Angelina A; Hotchkiss, Richard S; Kollef, Marin H

    2017-04-01

    To evaluate the impact of an emergency department mechanical ventilation protocol on clinical outcomes and adherence to lung-protective ventilation in patients with acute respiratory distress syndrome. Quasi-experimental, before-after trial. Emergency department and ICUs of an academic center. Mechanically ventilated emergency department patients experiencing acute respiratory distress syndrome while in the emergency department or after admission to the ICU. An emergency department ventilator protocol which targeted variables in need of quality improvement, as identified by prior work: 1) lung-protective tidal volume, 2) appropriate setting of positive end-expiratory pressure, 3) oxygen weaning, and 4) head-of-bed elevation. A total of 229 patients (186 preintervention group, 43 intervention group) were studied. In the emergency department, the intervention was associated with significant changes (p protective ventilation from 11.1% to 61.5%, p value of less than 0.01. The intervention was associated with a reduction in mortality from 54.8% to 39.5% (odds ratio, 0.38; 95% CI, 0.17-0.83; p = 0.02) and a 3.9 day increase in ventilator-free days, p value equals to 0.01. This before-after study of mechanically ventilated patients with acute respiratory distress syndrome demonstrates that implementing a mechanical ventilator protocol in the emergency department is feasible and associated with improved clinical outcomes.

  16. Effectiveness of Human Research Protection Program Performance Measurements.

    Science.gov (United States)

    Tsan, Min-Fu; Nguyen, Yen

    2017-10-01

    We analyzed human research protection program performance metric data of all Department of Veterans Affairs research facilities obtained from 2010 to 2016. Among a total of 25 performance metrics, 21 (84%) showed improvement, four (16%) remained unchanged, and none deteriorated during the study period. The overall improvement from these 21 performance metrics was 81.1% ± 18.7% (mean ± SD), with a range of 30% to 100%. The four performance metrics that did not show improvement all had initial noncompliance/incidence rates of performance metrics that showed improvement ranged from 0.05% to 60%. However, of the 21 performance metrics that showed improvement, 10 had initial noncompliance/incidence rates of performance measurement is an effective tool in improving the performance of human research protection programs.

  17. Personalizing mechanical ventilation for acute respiratory distress syndrome

    OpenAIRE

    Berngard, S. Clark; Beitler, Jeremy R.; Malhotra, Atul

    2016-01-01

    Lung-protective ventilation with low tidal volumes remains the cornerstone for treating patient with acute respiratory distress syndrome (ARDS). Personalizing such an approach to each patient's unique physiology may improve outcomes further. Many factors should be considered when mechanically ventilating a critically ill patient with ARDS. Estimations of transpulmonary pressures as well as individual's hemodynamics and respiratory mechanics should influence PEEP decisions as well as response ...

  18. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  19. The new ICRP respiratory model for radiation protection (ICRP 66) : applications and comparative evaluations

    International Nuclear Information System (INIS)

    Castellani, C.M.; Luciani, A.

    1996-02-01

    The aim of this report is to present the New ICRP Respiratory Model Tract for Radiological Protection. The model allows considering anatomical and physiological characteristics, giving reference values for children aged 3 months, 1, 5,10, and 15 years for adults; it also takes into account aerosol and gas characteristics. After a general description of the model structure, deposition, clearance and dosimetric models are presented. To compare the new and previous model (ICRP 30), dose coefficients (committed effective dose for unit intake) foe inhalation of radionuclides by workers are calculated considering aerosol granulometries with activity median aerodynamic of 1 and 5 μm, reference values for the respective publications. Dose coefficients and annual limits of intakes concerning respective dose limits (50 and 20 mSv respectively for ICRP 26 and 60) for workers and for members of population in case of dispersion of fission products aerosols, are finally calculated

  20. Role of secondary standard dosimetry laboratory in radiation protection program

    International Nuclear Information System (INIS)

    Rahman, Sohaila; Ali, Noriah Mohd.

    2008-01-01

    Full text: The radiation dosimetry program is an important element of operational radiation protection. Dosimetry data enable workers and radiation protection professionals to evaluate and control work practices to eliminate unnecessary exposure to ionizing radiation. The usefulness of the data produced however depends on its quality and traceability. The emphasis of the global dosimetry program is focused through the IAEA/WHO network of secondary standard dosimetry laboratories (SSDLs), which aims for the determination of SI quantities through proper traceable calibration of radiation protection equipment. The responsibility of SSDL-NUCLEAR MALAYSIA to guarantee a reliable dosimetry service, which is traceable to international standards, is elucidated. It acts as the basis for harmonized occupational radiation monitoring in Malaysia.

  1. The effect of Sub-maximal exercise-rehabilitation program on cardio-respiratory endurance indexes and oxygen pulse in patients with spastic cerebral palsy

    Directory of Open Access Journals (Sweden)

    M Izadi

    2006-05-01

    Full Text Available Background: Physical or cardio-respiratory fitness are of the best important physiological variables in children with cerebral palsy (CP, but the researches on exercise response of individuals with CP are limited. Our aim was to determine the effect of sub-maximal rehabilitation program (aerobic exercise on maximal oxygen uptake, oxygen pulse and cardio- respiratory physiological variables of children with moderate to severe spastic cerebral palsy diplegia and compare with able-bodied children. Methods: In a controlled clinical trial study, 15 children with diplegia spastic cerebral palsy, were recruited on a voluntarily basis (experimental group and 18 subjects without neurological impairments selected as control group. In CP group, aerobic exercise program performed on the average of exercise intensity (144 beat per minute of heart rate, 3 times a week for 3 months. The time of each exercise session was 20-25 minutes. Dependent variables were measured in before (pretest and after (post test of rehabilitation program through Mac Master Protocol on Tantories cycle ergometer in CP group and compared with the control group. Results: The oxygen pulse (VO2/HR during ergometery protocol was significantly lower in CP group than normal group (P<0.05. No significant statistical difference in maximal oxygen uptake (VO2 max was found between groups. The rehabilitation program leads to little increase of this variable in CP group. After sub-maximal exercise in pretest and post test, the heart rate of patient group was greater than control group, and aerobic exercise leads to significant decrease in heart rate in CP patients(P<0.05. Conclusion: The patients with spastic cerebral palsy, because of high muscle tone, severe spasticity and involuntarily movements have higher energy cost and lower aerobic fitness than normal people. The rehabilitation exercise program can improve physiological function of muscle and cardio-respiratory endurance in these

  2. Research on effectiveness assessment programs for physical protection system

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of)

    2015-05-15

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT.

  3. Research on effectiveness assessment programs for physical protection system

    International Nuclear Information System (INIS)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu

    2015-01-01

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT

  4. Programming Guidelines for FBD Programs in Reactor Protection System Software

    International Nuclear Information System (INIS)

    Jung, Se Jin; Lee, Dong Ah; Kim, Eui Sub; Yoo, Jun Beom; Lee, Jang Su

    2014-01-01

    Properties of programming languages, such as reliability, traceability, etc., play important roles in software development to improve safety. Several researches are proposed guidelines about programming to increase the dependability of software which is developed for safety critical systems. Misra-c is a widely accepted programming guidelines for the C language especially in the sector of vehicle industry. NUREG/CR-6463 helps engineers in nuclear industry develop software in nuclear power plant systems more dependably. FBD (Function Block Diagram), which is one of programming languages defined in IEC 61131-3 standard, is often used for software development of PLC (programmable logic controllers) in nuclear power plants. Software development for critical systems using FBD needs strict guidelines, because FBD is a general language and has easily mistakable elements. There are researches about guidelines for IEC 61131-3 programming languages. They, however, do not specify details about how to use languages. This paper proposes new guidelines for the FBD based on NUREG/CR-6463. The paper introduces a CASE (Computer-Aided Software Engineering) tool to check FBD programs with the new guidelines and shows availability with a case study using a FBD program in a reactor protection system. The paper is organized as follows

  5. Programming Guidelines for FBD Programs in Reactor Protection System Software

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Se Jin; Lee, Dong Ah; Kim, Eui Sub; Yoo, Jun Beom [Division of Computer Science and Engineering College of Information and Communication, Konkuk University, Seoul (Korea, Republic of); Lee, Jang Su [Man-Machine Interface System team Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Properties of programming languages, such as reliability, traceability, etc., play important roles in software development to improve safety. Several researches are proposed guidelines about programming to increase the dependability of software which is developed for safety critical systems. Misra-c is a widely accepted programming guidelines for the C language especially in the sector of vehicle industry. NUREG/CR-6463 helps engineers in nuclear industry develop software in nuclear power plant systems more dependably. FBD (Function Block Diagram), which is one of programming languages defined in IEC 61131-3 standard, is often used for software development of PLC (programmable logic controllers) in nuclear power plants. Software development for critical systems using FBD needs strict guidelines, because FBD is a general language and has easily mistakable elements. There are researches about guidelines for IEC 61131-3 programming languages. They, however, do not specify details about how to use languages. This paper proposes new guidelines for the FBD based on NUREG/CR-6463. The paper introduces a CASE (Computer-Aided Software Engineering) tool to check FBD programs with the new guidelines and shows availability with a case study using a FBD program in a reactor protection system. The paper is organized as follows.

  6. Respiratory guiding system for respiratory motion management in respiratory gated radiotherapy

    International Nuclear Information System (INIS)

    Kang, Seong Hee; Kim, Dong Su; Kim, Tae Ho; Suh, Tae Suk

    2013-01-01

    Respiratory guiding systems have been shown to improve the respiratory regularity. This, in turn, improves the efficiency of synchronized moving aperture radiation therapy, and it reduces the artifacts caused by irregular breathing in imaging techniques such as four-dimensional computed tomography (4D CT), which is used for treatment planning in RGRT. We have previously developed a respiratory guiding system that incorporates an individual-specific guiding waveform, which is easy to follow for each volunteer, to improve the respiratory regularity. The present study evaluates the application of this system to improve the respiratory regularity for respiratory-gated radiation therapy (RGRT). In this study, we evaluated the effectiveness of an in-house-developed respiratory guiding system incorporating an individual specific guiding waveform to improve the respiratory regularity for RGRT. Most volunteers showed significantly less residual motion at each phase during guided breathing owing to the improvement in respiratory regularity. Therefore, the respiratory guiding system can clearly reduce the residual, or respiratory, motion in each phase. From the result, the CTV and the PTV margins during RGRT can be reduced by using the respiratory guiding system, which reduces the residual motions, thus improving the accuracy of RGRT

  7. 75 FR 18850 - National Protection and Programs Directorate; Chemical Facility Anti-Terrorism Standards...

    Science.gov (United States)

    2010-04-13

    ... Directorate; Chemical Facility Anti-Terrorism Standards Personnel Surety Program AGENCY: National Protection...-terrorism Vulnerability Information (CVI), Sensitive Security Information (SSI), or Protected Critical... . SUPPLEMENTARY INFORMATION: Program Description The Chemical Facility Anti-Terrorism Standards (CFATS), 6 CFR...

  8. The role of radiologic technologist in radiation protection and quality assurance programs

    International Nuclear Information System (INIS)

    Djurovic, B.; Spasci -Jokic, V.; Misovic, M.

    2001-01-01

    The most important sources of ionizing radiation for general public are medical sources. Good working protocols and radiological protections measurements provided significant reduction of patients and professional doses. Medical users of ionizing radiation are radiological technologists. The purpose of this paper is to point out to several facts and errors in radiation protection educational programs for radiological technologists. Medical College educational program covers main specific topics in radiation protection, but there are some omissions in training process. Radiological technologists must be actively involved in radiation protection. Following ethical standards they will reach higher standards than the law requires

  9. Enhancement of Immune Memory Responses to Respiratory Infection

    Science.gov (United States)

    2017-08-01

    AWARD NUMBER: W81XWH-16-1-0360 TITLE: Enhancement of Immune Memory Responses to Respiratory Infection PRINCIPAL INVESTIGATORs: Dr Min Chen PhD...5a. CONTRACT NUMBER Enhancement of Immune Memory Responses to Respiratory Infection 5b. GRANT NUMBER W81XWH-16-1-0360 5c. PROGRAM ELEMENT NUMBER...entitled “ENHANCEMENT OF IMMUNE MEMORY RESPONSES TO RESPIRATORY INFECTION: AUTOPHAGY IN MEMORY B-CELLS RESPONSE TO INFLUENZA VACCINE (AMBRIV

  10. Accreditation of human research protection program: An Indian perspective

    Directory of Open Access Journals (Sweden)

    K L Bairy

    2012-01-01

    Full Text Available With the increasing number of clinical trials being placed in India, it is the collective responsibility of the Investigator sites, Government, Ethics Committees, and Sponsors to ensure that the trial subjects are protected from risks these studies can have, that subjects are duly compensated, and credible data generated. Most importantly, each institution/hospital should have a strong Human Research Protection Program to safe guard the trial subjects. In order to look at research with a comprehensive objective approach, there is a need for a formal auditing and review system by a recognized body. As of now, only the sponsors are monitoring/auditing their respective trials; however, there is an increasing need to perform a more detailed review and assessment of processes of the institution and the Ethics Committee. This challenge can be addressed by going for accreditation by a reputed association that encompasses-the institutions, the ethics committees, and researcher/research staff. Starting their journey for the accreditation process in late 2010, Kasturba Medical College and Hospital [KMC], Manipal, and Manipal Hospital Bangalore [MHB] received full Association for the Accreditation of Human Research Protection Programs (AAHRPP accreditation in Dec 2011-a first in India. This article delves into the steps involved in applying for AAHRPP accreditation from an Indian Perspective, the challenges, advantages, and testimonials from the two hospitals on the application experience and how the accreditation has improved the Human Research Protection Program at these hospitals.

  11. Extracorporeal respiratory support in adult patients

    Directory of Open Access Journals (Sweden)

    Thiago Gomes Romano

    Full Text Available ABSTRACT In patients with severe respiratory failure, either hypoxemic or hypercapnic, life support with mechanical ventilation alone can be insufficient to meet their needs, especially if one tries to avoid ventilator settings that can cause injury to the lungs. In those patients, extracorporeal membrane oxygenation (ECMO, which is also very effective in removing carbon dioxide from the blood, can provide life support, allowing the application of protective lung ventilation. In this review article, we aim to explore some of the most relevant aspects of using ECMO for respiratory support. We discuss the history of respiratory support using ECMO in adults, as well as the clinical evidence; costs; indications; installation of the equipment; ventilator settings; daily care of the patient and the system; common troubleshooting; weaning; and discontinuation.

  12. Development of a risk informed fire protection program

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, J.; McDevitt, B.; Sawyer, O.; Volk, M.A.; Drennan, J.; Sweely, C.

    2015-07-01

    Over the past decade, one of the largest challenges for the Nuclear Power Plant (NPP) Operator in the United States has been the implementation of risk-informed, performance-based (RI-PB) fire protection strategies into their fire protection program. Regardless of whether a utility decides to fully transition their licensing basis from deterministic to risk based, or if they simply complete a fire probabilistic risk assessment (FPRA) in order to augment their current program, it is clear that risk-informed, performance based fire protection strategies and the associated challenges are the growing trend in the United States and are here to stay. The experience of the nuclear industry in the United States with the implementation of RI-PB fire protection strategies can provide a great deal of insight for plants and utilities that follow, either by choice or necessity, a similar path. The similarities in the design of the United States and Spanish nuclear plants make these insights even more significant contributions to the strategy and planning for the Spanish fleet. The experience in United States will provide guidance to avoid similar missteps and better plan for the challenges of the transition process. As the Spanish fleet develops risk-informed and deterministic strategies to improve fire safety, an understanding of the challenges and lessons learned from the United States experience will save time and money. (Author)

  13. Effective personal protective clothing for health care workers attending patients with severe acute respiratory syndrome.

    Science.gov (United States)

    Wong, Thomas K S; Chung, Joanne W Y; Li, Y; Chan, Wai F; Ching, Patricia T Y; Lam, Conita H S; Chow, Chun B; Seto, Wing H

    2004-04-01

    Optimal usability is crucial in providing protection for health care workers who are exposed to severe acute respiratory syndrome day and night while taking care of patients with the virus. No research study has yet tested the usability of personal protective clothing (PPC). The study was carried out in 3 stages. PPC available in Hong Kong were sorted by their physical properties in the first stage. The second stage was a single-blinded study examining the different usability aspects of the PPC. The third stage was a simulated viral load test. Four types were identified: good water repellency and water resistance, poor air permeability (Type A PPC); good water repellency and air permeability, poor water resistance (Type B PPC); poor water repellency, poor water resistance, and fair air permeability (Type C PPC); and good water repellency, poor air permeability, and fair water resistance (Type D PPC). Type D PPC had a significantly higher number of contamination sites on the subjects' dorsum and palm. Type C PPC had the highest contamination over the trunk. Findings in the viral load test showed that there was a significant difference in the contamination of the face (t=4.69, df=38, Phand contamination is lowest among the 4 groups in the current study.

  14. 76 FR 34732 - Privacy Act of 1974; Department of Homeland Security/National Protection and Programs Directorate...

    Science.gov (United States)

    2011-06-14

    ... 1974; Department of Homeland Security/National Protection and Programs Directorate--002 Chemical... Homeland Security/National Protection and Programs Directorate--002 Chemical Facility Anti-Terrorism.... 552a, the Department of Homeland Security (DHS)/National Protection and Programs Directorate (NPPD...

  15. OSE inspection of protection program operations field perspective of inspections

    International Nuclear Information System (INIS)

    Brown, R.W.; Martin, H.R.

    1987-01-01

    Protection Program Operations includes three functional areas: Physical Protection Systems, Protective Forces, and System Performance Testing. The Office of Security Evaluations (OSE) inspects field offices in these areas by evaluating programs relative to Standards and Criteria and by performing a variety of exercises and other types of tests to assure protective systems are effective and maintained at a proper level to meet the defined threat. Their perception of the OSE inspections has been positive. The approach taken by ID, with key areas/activities emphasized, during each phase of the field inspection process is described in this report. The most important areas for field offices to concentrate are: inspection preparations through self-evaluation, improving communications, assigning knowledgeable trusted agents, increasing awareness of facility procedures and operations, and assuring daily validations of inspected areas. Emphasis is placed on striving for a balance in reporting both positive and negative findings, and for consistency between ratings and the importance of report findings. OSE efforts to develop improved rating methodologies are encouraged

  16. Low-flow venovenous CO₂ removal in association with lung protective ventilation strategy in patients who develop severe progressive respiratory acidosis after lung transplantation.

    Science.gov (United States)

    Ruberto, F; Bergantino, B; Testa, M C; D'Arena, C; Zullino, V; Congi, P; Paglialunga, S G; Diso, D; Venuta, F; Pugliese, F

    2013-09-01

    Primary graft dysfunction (PGD) might occur after lung transplantation. In some severe cases, conventional therapies like ventilatory support, administration of inhaled nitric oxide (iNO), and intravenous prostacyclins are not sufficient to provide an adequate gas exchange. The aim of our study was to evaluate the use of a lung protective ventilation strategy associated with a low-flow venovenous CO2 removal treatment to reduce ventilator-associated injury in patients that develop severe PGD after lung transplantation. From January 2009 to January 2011, 3 patients developed PGD within 24 hours after lung transplantation. In addition to conventional medical treatment, including hemodynamic support, iNO and prostaglandin E1 (PGE1), we initiated a ventilatory protective strategy associated with low-flow venovenous CO2 removal treatment (LFVVECCO2R). Hemodynamic and respiratory parameters were assessed at baseline as well as after 3, 12, 24, and 48 hours. No adverse events were registered. Despite decreased baseline elevated pulmonary positive pressures, application of a protective ventilation strategy with LFVVECCO2R reduced PaCO2 and pulmonary infiltrates as well as increased pH values and PaO2/FiO2 ratios. Every patient showed simultaneous improvement of clinical and hemodynamic conditions. They were weaned from mechanical ventilation and extubated after 24 hours after the use of the low-flow venovenous CO2 removal device. The use of LFVVECCO2R together with a protective lung ventilation strategy during the perioperative period of lung transplantation may be a valid clinical strategy for patients with PGD and severe respiratory acidosis occured despite adequate mechanical ventilation. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Poor Adherence to Lung-Protective Mechanical Ventilation in Pediatric Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Ward, Shan L; Quinn, Carson M; Valentine, Stacey L; Sapru, Anil; Curley, Martha A Q; Willson, Douglas F; Liu, Kathleen D; Matthay, Michael A; Flori, Heidi R

    2016-10-01

    To determine the frequency of low-tidal volume ventilation in pediatric acute respiratory distress syndrome and assess if any demographic or clinical factors improve low-tidal volume ventilation adherence. Descriptive post hoc analysis of four multicenter pediatric acute respiratory distress syndrome studies. Twenty-six academic PICU. Three hundred fifteen pediatric acute respiratory distress syndrome patients. All patients who received conventional mechanical ventilation at hours 0 and 24 of pediatric acute respiratory distress syndrome who had data to calculate ideal body weight were included. Two cutoff points for low-tidal volume ventilation were assessed: less than or equal to 6.5 mL/kg of ideal body weight and less than or equal to 8 mL/kg of ideal body weight. Of 555 patients, we excluded 240 for other respiratory support modes or missing data. The remaining 315 patients had a median PaO2-to-FIO2 ratio of 140 (interquartile range, 90-201), and there were no differences in demographics between those who did and did not receive low-tidal volume ventilation. With tidal volume cutoff of less than or equal to 6.5 mL/kg of ideal body weight, the adherence rate was 32% at hour 0 and 33% at hour 24. A low-tidal volume ventilation cutoff of tidal volume less than or equal to 8 mL/kg of ideal body weight resulted in an adherence rate of 58% at hour 0 and 60% at hour 24. Low-tidal volume ventilation use was no different by severity of pediatric acute respiratory distress syndrome nor did adherence improve over time. At hour 0, overweight children were less likely to receive low-tidal volume ventilation less than or equal to 6.5 mL/kg ideal body weight (11% overweight vs 38% nonoverweight; p = 0.02); no difference was noted by hour 24. Furthermore, in the overweight group, using admission weight instead of ideal body weight resulted in misclassification of up to 14% of patients as receiving low-tidal volume ventilation when they actually were not. Low

  18. Protecting Human Health in a Changing Environment: 2018 Summer Enrichment Program

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) in Research Triangle Park, NC is offering a free 1-week Summer Enrichment Program to educate students about how the Agency protects human health and the environment.

  19. Radiation protection program of Petrobras in industrial radiography area

    International Nuclear Information System (INIS)

    Signorini, M.

    1988-01-01

    Industrial hygiene has as main purpose the preservation of employees physical integrity when exposed to certain agressive agents. PETROBRAS Industrial hygiene program forecasts preventive policies in several specific fields. For the ionizing radiations area it was developed the ''Radiologic Protection Program'' which also deals with specific actions in industrial radiography jobs. These actions are hereinafter presented. (C.M.) [pt

  20. 76 FR 75458 - Servicemembers' Group Life Insurance Traumatic Injury Protection Program-Genitourinary Losses

    Science.gov (United States)

    2011-12-02

    ... Traumatic Injury Protection Program--Genitourinary Losses AGENCY: Department of Veterans Affairs. ACTION... Protection (TSGLI) program by adding certain genitourinary (GU) system losses to the TSGLI Schedule of Losses and defining terms relevant to these new losses. This amendment is necessary to make qualifying GU...

  1. The ICRP task group respiratory tract model - an age-dependent dosimetric model for general application

    International Nuclear Information System (INIS)

    Bailey, M.R.; Birchall, A.

    1992-01-01

    The ICRP Task Group on Human Respiratory Tract Models for Radiological Protection has developed a revised dosimetric model for the respiratory tract. Papers outlining the model, and describing each aspect of it were presented at the Third International Workshop on Respiratory Tract Dosimetry (Albuquerque 1-3 July 1990), the Proceedings of which were recently published in Radiation Protection Dosimetry Volume 38 Nos 1-3 (1991). Since the model had not changed substantially since the Workshop at Albuquerque, only a summary of the paper presented at Schloss Elmau is included in these Proceedings. (author)

  2. 78 FR 31955 - Privacy Act of 1974; Department of Homeland Security National Protection and Programs Directorate...

    Science.gov (United States)

    2013-05-28

    ... 1974; Department of Homeland Security National Protection and Programs Directorate--001 Arrival and... of records titled Department of Homeland Security/National Protection and Programs Directorate--001... of 1974, 5 U.S.C. 552a, the Department of Homeland Security (DHS) National Protection and Programs...

  3. Summary of fire protection programs of the United States Department of Energy

    International Nuclear Information System (INIS)

    1991-10-01

    This edition of the Annual Summary of DOE Fire Protection Programs continues the series started in 1972. Since May 1950, an annual report has been required from each field organization. The content has varied through the years and most of the accident data reporting requirements have been superseded by the Computerized Accident/Incident Reporting System administered by EG ampersand G, Idaho. However, this report is the sole source of information relating to fire protection programs, and to the actions of the field offices and to headquarters that are of general fire protection interest

  4. Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis

    NARCIS (Netherlands)

    Neto, Ary Serpa; Simonis, Fabienne D.; Barbas, Carmen S. V.; Biehl, Michelle; Determann, Rogier M.; Elmer, Jonathan; Friedman, Gilberto; Gajic, Ognjen; Goldstein, Joshua N.; Linko, Rita; Pinheiro de Oliveira, Roselaine; Sundar, Sugantha; Talmor, Daniel; Wolthuis, Esther K.; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J.

    2015-01-01

    Protective mechanical ventilation with low tidal volumes is standard of care for patients with acute respiratory distress syndrome. The aim of this individual patient data analysis was to determine the association between tidal volume and the occurrence of pulmonary complications in ICU patients

  5. Cellular immune responses to respiratory viruses

    NARCIS (Netherlands)

    van Helden, M.J.G.

    2011-01-01

    When a respiratory virus successfully infects the lungs, cascades of immune responses are initiated aimed to remove the pathogen. Immediate non-specific protection is provided by the innate immune system and this reduces the viral load during the first days of infection. The adaptive immune response

  6. Achieving a SALP-1 radiation protection program

    International Nuclear Information System (INIS)

    Andersen, R.L.; Slider, J.E.

    1992-01-01

    In 1987, the Detroit Edison Company embarked on an ambitious program to raise the performance of the radiation protection (RP) program at its Fermi-2 nuclear plant. The target chosen was a systematic assessment of licensee's performance (SALP)-1 rating by the US Nuclear Regulatory Commission (NRC). This goal was achieved in the spring of 1990. This paper summarizes key parts of the improvement program undertaken by Detroit Edison, lessons learned from this experience, and recommendations about applying the lessons learned at other sites. This information may be particularly helpful to commercial and federal government sites wishing to upgrade the performance of their RP programs. Excellence does not necessarily require great expenditures on new equipment or additional staff. It requires a willingness and ability to examine all functions of the RP department and an honest assessment of the most efficient means to accomplish those functions

  7. Increased GABA(A receptor ε-subunit expression on ventral respiratory column neurons protects breathing during pregnancy.

    Directory of Open Access Journals (Sweden)

    Keith B Hengen

    Full Text Available GABAergic signaling is essential for proper respiratory function. Potentiation of this signaling with allosteric modulators such as anesthetics, barbiturates, and neurosteroids can lead to respiratory arrest. Paradoxically, pregnant animals continue to breathe normally despite nearly 100-fold increases in circulating neurosteroids. ε subunit-containing GABA(ARs are insensitive to positive allosteric modulation, thus we hypothesized that pregnant rats increase ε subunit-containing GABA(AR expression on brainstem neurons of the ventral respiratory column (VRC. In vivo, pregnancy rendered respiratory motor output insensitive to otherwise lethal doses of pentobarbital, a barbiturate previously used to categorize the ε subunit. Using electrode array recordings in vitro, we demonstrated that putative respiratory neurons of the preBötzinger Complex (preBötC were also rendered insensitive to the effects of pentobarbital during pregnancy, but unit activity in the VRC was rapidly inhibited by the GABA(AR agonist, muscimol. VRC unit activity from virgin and post-partum females was potently inhibited by both pentobarbital and muscimol. Brainstem ε subunit mRNA and protein levels were increased in pregnant rats, and GABA(AR ε subunit expression co-localized with a marker of rhythm generating neurons (neurokinin 1 receptors in the preBötC. These data support the hypothesis that pregnancy renders respiratory motor output and respiratory neuron activity insensitive to barbiturates, most likely via increased ε subunit-containing GABA(AR expression on respiratory rhythm-generating neurons. Increased ε subunit expression may be critical to preserve respiratory function (and life despite increased neurosteroid levels during pregnancy.

  8. Constructing a resilience index for the Enhanced Critical Infrastructure Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, R. E.; Bassett, G. W.; Buehring, W. A.; Collins, M. J.; Dickinson, D. C.; Eaton, L. K.; Haffenden, R. A.; Hussar, N. E.; Klett, M. S.; Lawlor, M. A.; Millier, D. J.; Petit, F. D.; Peyton, S. M.; Wallace, K. E.; Whitfield, R. G.; Peerenboom, J P

    2010-10-14

    Following recommendations made in Homeland Security Presidential Directive 7, which established a national policy for the identification and increased protection of critical infrastructure and key resources (CIKR) by Federal departments and agencies, the U.S. Department of Homeland Security (DHS) in 2006 developed the Enhanced Critical Infrastructure Protection (ECIP) program. The ECIP program aimed to provide a closer partnership with state, regional, territorial, local, and tribal authorities in fulfilling the national objective to improve CIKR protection. The program was specifically designed to identify protective measures currently in place in CIKR and to inform facility owners/operators of the benefits of new protective measures. The ECIP program also sought to enhance existing relationships between DHS and owners/operators of CIKR and to build relationships where none existed (DHS 2008; DHS 2009). In 2009, DHS and its protective security advisors (PSAs) began assessing CIKR assets using the ECIP program and ultimately produced individual protective measure and vulnerability values through the protective measure and vulnerability indices (PMI/VI). The PMI/VI assess the protective measures posture of individual facilities at their 'weakest link,' allowing for a detailed analysis of the most vulnerable aspects of the facilities (Schneier 2003), while maintaining the ability to produce an overall protective measures picture. The PMI has six main components (physical security, security management, security force, information sharing, protective measures assessments, and dependencies) and focuses on actions taken by a facility to prevent or deter the occurrence of an incident (Argonne National Laboratory 2009). As CIKR continue to be assessed using the PMI/VI and owners/operators better understand how they can prevent or deter incidents, academic research, practitioner emphasis, and public policy formation have increasingly focused on resilience as a

  9. Environmental Guidance Program Reference Book: Marine Protection, Research, and Sanctuaries Act and Marine Mammal Protection Act. Revision 3

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-31

    Two laws governing activities in the marine environment are considered in this Reference Book. The Marine Protection, Research, and Sanctuaries Act (MPRSA, P.L. 92-532) regulates ocean dumping of waste, provides for a research program on ocean dumping, and provides for the designation and regulation of marine sanctuaries. The Marine Mammal Protection Act (MMPA, P.L. 92-522) establishes a federal program to protect and manage marine mammals. The Fishery Conservation and Management Act (FCMA, P.L. 94-265) establishes a program to regulate marine fisheries resources and commercial marine fishermen. Because the Department of Energy (DOE) is not engaged in any activities that could be classified as fishing under FCMA, this Act and its regulations have no implications for the DOE; therefore, no further consideration of this Act is given within this Reference Book. The requirements of the MPRSA and the MMPA are discussed in terms of their implications for the DOE.

  10. Radiation safety and protection in US dental hygiene programs

    International Nuclear Information System (INIS)

    Farman, A.G.; Hunter, N.; Grammer, S.

    1986-01-01

    A survey of radiation safety and protection measures used by programs teaching dental hygiene indicated some areas for concern. No barriers or radiation shieldings were used between operator and patient in four programs. Radiation monitoring devices were not worn by faculty operators in 16% of the programs. Fewer than half of the programs used thyroid shields for patients on a routine basis. Insufficient filtration for the kilovolt peak employed was used by 14% of the programs, and for 19% more the filtration was unknown or unspecified. Three programs used closed cones. Rectangular collimation was not used at all by 63% of the programs, and only 20% used E speed film routinely. Quality assurance for equipment maintenance and for film processing were in place at only 54% and 49% of the programs, respectively

  11. A survey of research programs in radiation protection in Canada

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    A survey of research programs in Canada concerned with radiation protection was conducted in 1991-92 by the Joint Subcommittee on Regulatory Research (JSCRR) of the Atomic Energy Control Board (AECB) Advisory Committees on Radiological Protection and on Nuclear Safety. The purpose of this survey was to determine the current state of funding for this type of research in Canada. Funding for health-related radiation research in Canada is critical to establishing and maintaining a supply of trained professionals who can provide competent advice on health-related problems in radiation protection. The present report is an analysis of the information received in this survey. This survey concludes with the recommendation that the organization and definition of subprograms for the AECB Regulatory Research and Support Program should be completed as soon as possible. In this report the JSCRR should assist AECB staff in preparing a report in which priorities for research related to radiation protection are indicated. The sources of information noted at the end of the Discussion section of this report should be considered for this purpose. (author). 15 refs., 3 tabs.

  12. A survey of research programs in radiation protection in Canada

    International Nuclear Information System (INIS)

    1995-07-01

    A survey of research programs in Canada concerned with radiation protection was conducted in 1991-92 by the Joint Subcommittee on Regulatory Research (JSCRR) of the Atomic Energy Control Board (AECB) Advisory Committees on Radiological Protection and on Nuclear Safety. The purpose of this survey was to determine the current state of funding for this type of research in Canada. Funding for health-related radiation research in Canada is critical to establishing and maintaining a supply of trained professionals who can provide competent advice on health-related problems in radiation protection. The present report is an analysis of the information received in this survey. This survey concludes with the recommendation that the organization and definition of subprograms for the AECB Regulatory Research and Support Program should be completed as soon as possible. In this report the JSCRR should assist AECB staff in preparing a report in which priorities for research related to radiation protection are indicated. The sources of information noted at the end of the Discussion section of this report should be considered for this purpose. (author). 15 refs., 3 tabs

  13. Continuing training program in radiation protection in biological research centers

    International Nuclear Information System (INIS)

    Escudero, R.; Hidalgo, R.M.; Usera, F.; Macias, M.T.; Mirpuri, E.; Perez, J.; Sanchez, A.

    2008-01-01

    specific training program in radiation protection to meet the different needs of all workers in a biological research center. This program aims to ensure compliance with the relevant national legislation and to minimize the possibility of radiological incidents and accidents in this kind of center. This study has involved contributions from six nationally and internationally recognized Spanish biological research centers that have active training programs in radiation protection, and the design of the program presented here has been informed by the teaching experience of the training staff involved. The training method is based on introductory and refresher courses for personnel in direct contact with the radioactive facility and also for indirectly associated personnel. The courses will include guideline manuals (print or electronic), training through seminars or online materials, and also personnel evaluation, visits to the radioactive facility or practical training as required. The introductory courses are intended for newly incorporated personnel. The refresher courses are fundamentally designed to accommodate possible changes to national legal regulations, working conditions or the in-house radiological protection controls. Maintenance and instrumentation workers, cleaners, administrative personnel, etc. who are associated with the radioactive facility indirectly. These workers are affected by the work in the radioactive facility to varying degrees, and they therefore also require information and training in radiological protection tailored to their level of interaction with the installation. The aim of this study was to design a specific training program in radiation protection to meet the different needs of all workers in a biological research center. This program aims to ensure compliance with the relevant national legislation and to minimize the possibility of radiological incidents and accidents in this kind of center. This study has involved contributions from

  14. Use of the analytical tree technique to develop a radiological protection program

    International Nuclear Information System (INIS)

    Domenech N, H.; Jova S, L.

    1996-01-01

    The results obtained by the Cuban Center for Radiological Protection and Hygiene by using an analytical tree technique to develop its general operational radiation protection program are presented. By the application of this method, some factors such as the organization of the radiation protection services, the provision of administrative requirements, the existing general laboratories requirements, the viability of resources and the current documentation was evaluated. Main components were considered such as: complete normative and regulatory documentation; automatic radiological protection data management; scope of 'on the-job'and radiological protection training for the personnel; previous radiological appraisal for the safety performance of the works and application of dose constrains for the personnel and the public. The detailed development of the program allowed to identify the basic aims to be achieved in its maintenance and improvement. (authors). 3 refs

  15. TOXIC EFFECTS OF CHLOROPICRIN AND IMPACT OF SORBED WATER STEAM ON PROTECTION

    Directory of Open Access Journals (Sweden)

    Milena Nikolić

    2013-01-01

    Full Text Available Chloropicrin is a chemical substance that has a very toxic effect. Exerts its effect on the respiratory system. Causes pulmonary edema and difficult breathing and suffocating effect. Respiratory protection may be carried into execution respiratory filters. On the protective power filter based on active coal affects adsorbed water vapor. This paper presents the results of the adsorption of water vapor on activated carbon from 5% to 25%. Was used for the experiment apparatus for dynamic adsorption, the results showed that the humidity of 5% coal provides most power protection, while humidity of 25% minimum protective power.

  16. Personalizing mechanical ventilation for acute respiratory distress syndrome.

    Science.gov (United States)

    Berngard, S Clark; Beitler, Jeremy R; Malhotra, Atul

    2016-03-01

    Lung-protective ventilation with low tidal volumes remains the cornerstone for treating patient with acute respiratory distress syndrome (ARDS). Personalizing such an approach to each patient's unique physiology may improve outcomes further. Many factors should be considered when mechanically ventilating a critically ill patient with ARDS. Estimations of transpulmonary pressures as well as individual's hemodynamics and respiratory mechanics should influence PEEP decisions as well as response to therapy (recruitability). This summary will emphasize the potential role of personalized therapy in mechanical ventilation.

  17. Development of Environmental Education Programs for Protected Areas in Madagascar

    Science.gov (United States)

    Ormsby, Alison

    2007-01-01

    Environmental education programs for schools in the peripheral zone of protected areas in Madagascar are still needed in numerous locations. My research investigated the status of environmental education and communication (EE&C) programs at Masoala National Park, Madagascar, as well as the attitudes of local residents toward the park and park…

  18. Constructing vulnerabilty and protective measures indices for the enhanced critical infrastructure protection program.

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, R. E.; Buehring, W. A.; Whitfield, R. G.; Bassett, G. W.; Dickinson, D. C.; Haffenden, R. A.; Klett, M. S.; Lawlor, M. A.; Decision and Information Sciences; LANL

    2009-10-14

    The US Department of Homeland Security (DHS) has directed its Protective Security Advisors (PSAs) to form partnerships with the owners and operators of assets most essential to the Nation's well being - a subclass of critical infrastructure and key resources (CIKR) - and to conduct site visits for these and other high-risk assets as part of the Enhanced Critical Infrastructure Protection (ECIP) Program. During each such visit, the PSA documents information about the facility's current CIKR protection posture and overall security awareness. The primary goals for ECIP site visits (DHS 2009) are to: (1) inform facility owners and operators of the importance of their facilities as an identified high-priority CIKR and the need to be vigilant in light of the ever-present threat of terrorism; (2) identify protective measures currently in place at these facilities, provide comparisons of CIKR protection postures across like assets, and track the implementation of new protective measures; and (3) enhance existing relationships among facility owners and operators; DHS; and various Federal, State, local tribal, and territorial partners. PSAs conduct ECIP visits to assess overall site security; educate facility owners and operators about security; help owners and operators identify gaps and potential improvements; and promote communication and information sharing among facility owners and operators, DHS, State governments, and other security partners. Information collected during ECIP visits is used to develop metrics; conduct sector-by-sector and cross-sector vulnerability comparisons; identify security gaps and trends across CIKR sectors and subsectors; establish sector baseline security survey results; and track progress toward improving CIKR security through activities, programs, outreach, and training (Snyder 2009). The data being collected are used in a framework consistent with the National Infrastructure Protection Plan (NIPP) risk criteria (DHS 2009). The

  19. Mask-wearing and respiratory infection in healthcare workers in Beijing, China

    Directory of Open Access Journals (Sweden)

    Peng Yang

    Full Text Available OBJECTIVES: The aim of the study was to determine rates of mask-wearing, of respiratory infection and the factors associated with mask-wearing and of respiratory infection in healthcare workers (HCWs in Beijing during the winter of 2007/2008. METHODS: We conducted a survey of 400 HCWs working in eight hospitals in Beijing by face to face interview using a standardized questionnaire. RESULTS: We found that 280/400 (70.0% of HCWs were compliant with mask-wearing while in contact with patients. Respiratory infection occurred in 238/400 (59.5% subjects from November, 2007 through February, 2008. Respiratory infection was higher among females (odds ratio [OR], 2.00 [95% confidence interval {CI}, 1.16-3.49] and staff working in larger hospitals (OR, 1.72 [95% CI, 1.092.72], but was lower among subjects with seasonal influenza vaccination (OR, 0.46 [95% CI, 0.280.76], wearing medical masks (reference: cotton-yarn; OR, 0.60 [95% CI, 0.39-0.91] or with good mask-wearing adherence (OR, 0.60 [95% CI, 0.37-0.98]. The risk of respiratory infection of HCWs working in low risk areas was similar to that of HCWs in high risk area. CONCLUSION: Our data suggest that female HCWs and staffs working in larger hospitals are the focus of prevention and control of respiratory infection in Beijing hospitals. Mask-wearing and seasonal influenza vaccination are protective for respiratory infection in HCWs; the protective efficacy of medical masks is better than that of cotton yarn ones; respiratory infection of HCWs working in low risk areas should also be given attention.

  20. Oestrogen influences on mitochondrial gene expression and respiratory chain activity in cortical and mesencephalic astrocytes.

    Science.gov (United States)

    Araújo, G W; Beyer, C; Arnold, S

    2008-07-01

    The regulation of mitochondrial energy metabolism plays an essential role in the central nervous system (CNS). Abnormalities of the mitochondrial respiratory chain often accompany neurodegenerative diseases. This makes mitochondria a perfect target for strategies of cellular protection against toxic compounds and pathological conditions. Steroid hormones, such as oestrogen, are well-known to fulfil a protective role in the brain during ischaemic and degenerative processes. Because astrocytes function as the major energy supplier in the CNS, we have analysed oestrogen effects on the mitochondrial respiratory chain of this cell type. In our studies, we applied semi- and quantitative polymerase chain reaction analysis of gene expression and polarographic measurements of the respiratory chain activity of mitochondria. We observed that structural and functional properties were regulated dependent on the oestrogen exposure time and the brain region, but independent of the nuclear oestrogen receptors. We could demonstrate that long-term oestrogen exposure increases the subunit gene expression of respiratory chain complexes and the mitochondrial DNA content, thereby indicating an up-regulation of the amount of mitochondria per cell together with an increase of mitochondrial energy production. This could represent an important indirect mechanism by which long-term oestrogen exposure protects neurones from cell death under neurotoxic conditions. On the other hand, we observed short-term effects of oestrogen on the activity of mitochondrial, proton-pumping respiratory chain complexes. In astrocytes from the cortex, respiratory chain activity was decreased, whereas it was increased in astrocytes from the mesencephalon. An increased production of reactive oxygen species would be the consequence of an increased respiratory chain activity in mesencephalic astrocytes. This could explain the different efficiencies of oestrogen-mediated short-term protection in distinct brain

  1. Technical methods for a risk-informed, performance-based fire protection program at nuclear power plants

    International Nuclear Information System (INIS)

    Dey, M.K.

    1998-01-01

    This paper presents a technical review and examination of technical methods that are available for developing a risk-informed, performance-based fire protection program at a nuclear plant. The technical methods include ''engineering tools'' for examining the fire dynamics of fire protection problems, reliability techniques for establishing an optimal fire protection surveillance program, fire computer codes for analyzing important fire protection safety parameters, and risk-informed approaches that can range from drawing qualitative insights from risk information to quantifying the risk impact of alternative fire protection approaches. Based on this technical review and examination, it is concluded that methods for modeling fires, and reliability and fire PRA analyses are currently available to support the initial implementation of simple risk-informed, performance-based approaches in fire protection programs. (author)

  2. Technical methods for a risk-informed, performance-based fire protection program at nuclear power plants

    International Nuclear Information System (INIS)

    Dey, M.K.

    2000-01-01

    This paper presents a technical review and examination of technical methods that are available for developing a risk-informed, performance-based fire protection program at a nuclear plant. The technical methods include 'engineering tools' for examining the fire dynamics of fire protection problems, reliability techniques for establishing an optimal fire protection surveillance program, fire computer codes for analyzing important fire protection safety parameters, and risk-informed approaches that can range from drawing qualitative insights from risk information to quantifying the risk impact of alternative fire protection approaches. Based on this technical review and examination, it is concluded that methods for modeling fires, and reliability and fire probabilistic risk analyses (PRA) are currently available to support the initial implementation of simple risk-informed, performance-based approaches in fire protection programs. (orig.) [de

  3. Propagation prevention: a complementary mechanism for "lung protective" ventilation in acute respiratory distress syndrome.

    Science.gov (United States)

    Marini, John J; Gattinoni, Luciano

    2008-12-01

    To describe the clinical implications of an often neglected mechanism through which localized acute lung injury may be propagated and intensified. Experimental and clinical evidence from the medical literature relevant to the airway propagation hypothesis and its consequences. The diffuse injury that characterizes acute respiratory distress syndrome is often considered a process that begins synchronously throughout the lung, mediated by inhaled or blood-borne noxious agents. Relatively little attention has been paid to possibility that inflammatory lung injury may also begin focally and propagate sequentially via the airway network, proceeding mouth-ward from distal to proximal. Were this true, modifications of ventilatory pattern and position aimed at geographic containment of the injury process could help prevent its generalization and limit disease severity. The purposes of this communication are to call attention to this seldom considered mechanism for extending lung injury that might further justify implementation of low tidal volume/high positive end-expiratory pressure ventilatory strategies for lung protection and to suggest additional therapeutic measures implied by this broadened conceptual paradigm.

  4. Planetary Protection Bioburden Analysis Program

    Science.gov (United States)

    Beaudet, Robert A.

    2013-01-01

    This program is a Microsoft Access program that performed statistical analysis of the colony counts from assays performed on the Mars Science Laboratory (MSL) spacecraft to determine the bioburden density, 3-sigma biodensity, and the total bioburdens required for the MSL prelaunch reports. It also contains numerous tools that report the data in various ways to simplify the reports required. The program performs all the calculations directly in the MS Access program. Prior to this development, the data was exported to large Excel files that had to be cut and pasted to provide the desired results. The program contains a main menu and a number of submenus. Analyses can be performed by using either all the assays, or only the accountable assays that will be used in the final analysis. There are three options on the first menu: either calculate using (1) the old MER (Mars Exploration Rover) statistics, (2) the MSL statistics for all the assays, or This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software

  5. The revised International Commission on Radiological Protection (ICRP) dosimetric model for the human respiratory tract

    International Nuclear Information System (INIS)

    Bair, W.J.

    1992-05-01

    A task group has revised the dosimetric model of the respiratory tract used to calculate annual limits on intake of radionuclides. The revised model can be used to project respiratory tract doses for workers and members of the public from airborne radionuclides and to assess past exposures. Doses calculated for specific extrathoracic and thoracic tissues can be adjusted to account for differences in radiosensitivity and summed to yield two values of dose for the respiratory tract that are applicable to the ICRP tissue weighted dosimetry system

  6. 75 FR 82037 - National Protection and Programs Directorate; President's National Security Telecommunications...

    Science.gov (United States)

    2010-12-29

    ... DEPARTMENT OF HOMELAND SECURITY [Docket No. DHS-2010-0050] National Protection and Programs Directorate; President's National Security Telecommunications Advisory Committee AGENCY: National Protection... Committee Meeting. SUMMARY: The President's National Security Telecommunications Advisory Committee (NSTAC...

  7. Respiratory care management information systems.

    Science.gov (United States)

    Ford, Richard M

    2004-04-01

    Hospital-wide computerized information systems evolved from the need to capture patient information and perform billing and other financial functions. These systems, however, have fallen short of meeting the needs of respiratory care departments regarding work load assessment, productivity management, and the level of outcome reporting required to support programs such as patient-driven protocols. The respiratory care management information systems (RCMIS) of today offer many advantages over paper-based systems and hospital-wide computer systems. RCMIS are designed to facilitate functions specific to respiratory care, including assessing work demand, assigning and tracking resources, charting, billing, and reporting results. RCMIS incorporate mobile, point-of-care charting and are highly configurable to meet the specific needs of individual respiratory care departments. Important and substantial benefits can be realized with an RCMIS and mobile, wireless charting devices. The initial and ongoing costs of an RCMIS are justified by increased charge capture and reduced costs, by way of improved productivity and efficiency. It is not unusual to recover the total cost of an RCMIS within the first year of its operation. In addition, such systems can facilitate and monitor patient-care protocols and help to efficiently manage the vast amounts of information encountered during the practitioner's workday. Respiratory care departments that invest in RCMIS have an advantage in the provision of quality care and in reducing expenses. A centralized respiratory therapy department with an RCMIS is the most efficient and cost-effective way to monitor work demand and manage the hospital-wide allocation of respiratory care services.

  8. Coordination Between the HEU Transparency Program and the Material Protection, Control and Accountability Program

    International Nuclear Information System (INIS)

    Glaser, J.; Hernandez, J.; Dougherty, D.; Bieniawski, A.; Cahalane, P.; Mastal, E.

    2000-01-01

    DOE sponsored programs such as Material Protection Control and Accountability (MPC and A) and implementation of the Highly-Enriched Uranium (HEU) Transparency Program send US personnel into Russian nuclear facilities and receive Russian representatives from these programs. While there is overlap in the Russian nuclear facilities visited by these two programs, there had not been any formal mechanism to share information between them. Recently, an MPC and A/HEU Working Group was developed to facilitate the sharing of appropriate information and to address concerns expressed by Minatom and Russian facility personnel such as US visit scheduling conflicts. This paper discusses the goals of the Working Group and ways it has helped to allow the programs to work more efficiently with the Russian facilities

  9. Pregnant Employee Protection Program in a Large Chemical Company.

    Science.gov (United States)

    Frey, Gunild; Schuster, Michael; Oberlinner, Christoph; Queier-Wahrendorf, Annette; Lang, Stefan; Yong, Mei

    2015-09-01

    To assess whether a structured employee protection program for pregnant workers at a chemical company has an impact on pregnancy outcomes. Reported pregnancies (n = 1402) between 2003 and 2010 and their outcomes were documented using questionnaires at the time of pregnancy report, end of pregnancy, and 1 year later. Potential maternal exposures were assessed using job histories, workplace inspections, and questionnaires. Participation was 86% overall and was consistently high across subgroups.Pregnancy losses (10.9%), pregnancy complications, and preterm births (8.1%) were in agreement with rates in the general population and were independent of type of work and maternal exposure category. Pregnancy complication rates in this chemical company are not statistically elevated than that in the general population, as suggested in a previous study. The protection program may play a role in preventing complications that may have occurred.

  10. Physical activity and respiratory muscle strength in elderly: a systematic review

    Directory of Open Access Journals (Sweden)

    Fabio Dutra Pereira

    Full Text Available Introduction The aging will inevitably bring some kind of functional decline in elderly, sarcopenia in this sense stands out because it damages the muscle function and extend also to the respiratory muscles. Objective Systematically review studies that have sought to compare the strength of respiratory muscles between sedentary and physically active elderly in training programs nonspecific respiratory musculature. Materials and methods From the descriptors motor activity, respiratory muscles and elderly, the databases LILACS, MedLine, Cochrane, PEDro, Scirus and Redalyc were consulted. Results Of 1.263 experiments available in said databases, 12 were recovered and 6 were selected due they meet all the inclusion criteria and selection requirements. Conclusion Physical activity programs offered by the selected studies led physically active elderly to have respiratory muscle strength statistically higher than the sedentary. However, this condition did not expressed itself as security to these elderly to present strength levels above of the minimum predictive of normality.

  11. Effectiveness of REDD programs in the protection of sui generis indigenous rights

    Directory of Open Access Journals (Sweden)

    Paloma Infante M.

    2013-06-01

    Full Text Available The article focuses on the implementation of the United Nations Reducing Emission from Deforestation and Forest Degradation Program, hereinafter UN REDD and its effectiveness in the protection of sui generis indigenous rights, meaning those different from the property right but derived from it, especially, the rights over the territories, natural resources and environmental services. The paper will cover the interconnection between sui generis indigenous rights and REDD programs including the relevance of land tenure and the sui generis rights derived from it. As we will emphasize, REDD programs are not only focused in the reduction of carbon emissions. In fact, REDD plus programs include as a main objective the sustainable management of forests and the protection to forest dependent communities.

  12. Epidemiologic analysis of respiratory viral infections among Singapore military servicemen in 2016.

    Science.gov (United States)

    Lau, Yuk-Fai; Koh, Wee-Hong Victor; Kan, Clement; Dua, Poh-Choo Alethea; Lim, Ai-Sim Elizabeth; Liaw, Chin-Wen Jasper; Gao, Qiu-Han; Chng, Jeremiah; Lee, Vernon J; Tan, Boon-Huan; Loh, Jin-Phang

    2018-03-12

    Respiratory illnesses have been identified as a significant factor leading to lost training time and morbidity among Singapore military recruits. A surveillance programme has been put in place to determine etiological agents responsible for febrile, as well as afebrile respiratory illnesses in a military camp. The goal of the study is to better understand the epidemiology of these diseases and identify potential countermeasures to protect military recruits against them. From Jan 2016 - Jan 2017, a total of 2647 respiratory cases were enrolled into the surveillance programme. The cases were further stratified into Febrile Respiratory Illness (FRI, with body temperature > 37.5 °C) or Acute Respiratory Illness (ARI, with body temperature respiratory diseases in military focused largely on FRI cases. With the expanded surveillance to ARI cases, this study allows unbiased evaluation of the impact of respiratory disease pathogens among recruits in a military environment. The results show that several pathogens have a much bigger role in causing respiratory diseases in this cohort.

  13. Severe acute respiratory syndrome vaccine efficacy in ferrets: whole killed virus and adenovirus-vectored vaccines.

    Science.gov (United States)

    See, Raymond H; Petric, Martin; Lawrence, David J; Mok, Catherine P Y; Rowe, Thomas; Zitzow, Lois A; Karunakaran, Karuna P; Voss, Thomas G; Brunham, Robert C; Gauldie, Jack; Finlay, B Brett; Roper, Rachel L

    2008-09-01

    Although the 2003 severe acute respiratory syndrome (SARS) outbreak was controlled, repeated transmission of SARS coronavirus (CoV) over several years makes the development of a SARS vaccine desirable. We performed a comparative evaluation of two SARS vaccines for their ability to protect against live SARS-CoV intranasal challenge in ferrets. Both the whole killed SARS-CoV vaccine (with and without alum) and adenovirus-based vectors encoding the nucleocapsid (N) and spike (S) protein induced neutralizing antibody responses and reduced viral replication and shedding in the upper respiratory tract and progression of virus to the lower respiratory tract. The vaccines also diminished haemorrhage in the thymus and reduced the severity and extent of pneumonia and damage to lung epithelium. However, despite high neutralizing antibody titres, protection was incomplete for all vaccine preparations and administration routes. Our data suggest that a combination of vaccine strategies may be required for effective protection from this pathogen. The ferret may be a good model for SARS-CoV infection because it is the only model that replicates the fever seen in human patients, as well as replicating other SARS disease features including infection by the respiratory route, clinical signs, viral replication in upper and lower respiratory tract and lung damage.

  14. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    International Nuclear Information System (INIS)

    1993-01-01

    The DOE has mandated in DOE Order 5400.1 that its operations will be conducted in an environmentally safe manner. The Waste Isolation Pilot Plant (WIPP) will comply with DOE Order 5400.1 and will conduct its operations in a manner that ensures the safety of the environment and the public. This document outlines how the WIPP will protect and preserve groundwater within and surrounding the WIPP facility. Groundwater protection is just one aspect of the WIPP environmental protection effort. The WIPP groundwater surveillance program is designed to determine statistically if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will be determined and appropriate corrective action initiated

  15. Sun Protection is Fun! A Skin Cancer Prevention Program for Preschools.

    Science.gov (United States)

    Tripp, Mary K.; Herrmann, Nancy B.; Parcel, Guy S.; Chamberlin, Robert M.; Gritz, Ellen R.

    2000-01-01

    Describes the Sun Protection is Fun! skin cancer prevention program for preschool children that features intervention methods grounded in social cognitive theory and emphasizes symbolic modeling, vicarious learning, enactive mastery experiences, and persuasion. Program components include a curriculum and teacher's guide, videos, newsletters,…

  16. Development and implementation of a comprehensive groundwater protection program at the Savannah River Plant

    International Nuclear Information System (INIS)

    Gordon, D.E.

    1984-01-01

    The major goals of the groundwater protection program are to evaluate the impact on groundwater quality as a result of Savannah River Plant operations, to take corrective measures as required to restore or protect groundwater quality, and to ensure that future operations do not adversely affect the quality or availability of the groundwater resources at the site. The specific elements of this program include (1) continuation of an extensive groundwater monitoring program, (2) assessment of waste disposal sites for impacts on groundwater quality, (3) implementation of mitigative actions, as required, to restore or protect groundwater quality, (4) incorporation of groundwater protection concepts in the design of new production and waste management facilities, and (5) review of site utilization of groundwater resources to ensure compatibility with regional needs. The major focal points of the groundwater protection program are the assessment of waste disposal sites for impacts on groundwater quality and the implementation of remedial action projects. Many locations at SRP have been used as waste disposal sites for a variety of liquid and solid wastes. Field investigations are ongoing to determine the nature and extent of any contamination in the sediments and groundwater at these waste sites on a priority basis. Remedial action has been initiated. Certain aspects of the groundwater protection program have been identified as key to the success in achieving the desired objectives. Key elements of the program have included early identification of all the potential sources for groundwater contamination, development of an overall strategy for waste site assessment and mitigation, use of a flexible computerized system for data base management, and establishing good relationships with regulatory agencies. 10 references, 6 figures, 4 tables

  17. Memory CD8 T cells mediate severe immunopathology following respiratory syncytial virus infection.

    Directory of Open Access Journals (Sweden)

    Megan E Schmidt

    2018-01-01

    Full Text Available Memory CD8 T cells can provide protection from re-infection by respiratory viruses such as influenza and SARS. However, the relative contribution of memory CD8 T cells in providing protection against respiratory syncytial virus (RSV infection is currently unclear. To address this knowledge gap, we utilized a prime-boost immunization approach to induce robust memory CD8 T cell responses in the absence of RSV-specific CD4 T cells and antibodies. Unexpectedly, RSV infection of mice with pre-existing CD8 T cell memory led to exacerbated weight loss, pulmonary disease, and lethal immunopathology. The exacerbated disease in immunized mice was not epitope-dependent and occurred despite a significant reduction in RSV viral titers. In addition, the lethal immunopathology was unique to the context of an RSV infection as mice were protected from a normally lethal challenge with a recombinant influenza virus expressing an RSV epitope. Memory CD8 T cells rapidly produced IFN-γ following RSV infection resulting in elevated protein levels in the lung and periphery. Neutralization of IFN-γ in the respiratory tract reduced morbidity and prevented mortality. These results demonstrate that in contrast to other respiratory viruses, RSV-specific memory CD8 T cells can induce lethal immunopathology despite mediating enhanced viral clearance.

  18. Reducing Error, Fraud and Corruption (EFC) in Social Protection Programs

    OpenAIRE

    Tesliuc, Emil Daniel; Milazzo, Annamaria

    2007-01-01

    Social Protection (SP) and Social Safety Net (SSN) programs channel a large amount of public resources, it is important to make sure that these reach the intended beneficiaries. Error, fraud, or corruption (EFC) reduces the economic efficiency of these interventions by decreasing the amount of money that goes to the intended beneficiaries, and erodes the political support for the program. ...

  19. Physical protection educational program - information security aspects

    International Nuclear Information System (INIS)

    Tolstoy, A.

    2002-01-01

    Full text: Conceptual approaches for designing an expert training program on object physical protection taking into account information security aspects are examined. A special educational course does not only address the immediate needs for an educational support but also ensures that new professionals include new concepts and knowledge in their practice and encourages current practitioners towards such practice. Features of the modern physical protection systems (PPS) and classification of information circulating at them are pointed out. The requirements to the PPS information protection subsystem are discussed. During the PPS expert training on information security (IS) aspects they should receive certain knowledge, on the basis of which they could competently define and carry out the PPS IS policy for a certain object. Thus, it is important to consider minimally necessary volume of knowledge taught to the PPS experts for independent and competent implementation of the above listed tasks. For the graduate PPS IS expert training it is also necessary to examine the normative and legal acts devoted to IS as a whole and the PPS IS in particular. It is caused by necessity of conformity of methods and information protection tools implemented on a certain object to the federal and departmental IS requirements. The departmental normative IS requirements define an orientation of the PPS expert training. By curriculum development it is necessary to precisely determine for whom the PPS experts are taught. The curriculum should reflect common features of the PPS functioning of the certain object type, i.e. it should be adapted to a certain customer of the experts. The specified features were taken into account by development of an educational course 'Information security of the nuclear facility physical protection systems', taught at the Moscow Engineering Physics Institute (State University) according to the Russian-American educational program 'Master in Physical

  20. Programming microphysiological systems for children's health protection (SEBM meeting)

    Science.gov (United States)

    Presentation: Programming microphysiological systems for children’s health protectionAuthors: Knudsen1 T, Klieforth2 B, and Slikker3 W Jr.1National Center for Computational Toxicology/EPA, Research Triangle Park NC2National Center for Environmental Research/EPA, Washington DC3Nat...

  1. Radiation protection program at an accelerator facility complex

    International Nuclear Information System (INIS)

    Ramanuja, Jaya

    2007-01-01

    Broad aspects of Radiation Protection Program at the Tyco Healthcare/Mallinckrodt Inc. will be presented with emphasis on Occupational dose, Public dose and ALARA program. Regulatory requirements, compliance and radio nuclides of concern for external exposure and internal contamination will be discussed. The facility is subject to in depth annual inspections by the Nuclear Regulatory Commission (NRC) to ensure compliance with regulations and operating license requirements. The facility is required to have an emergency contingency plan in place. A simulated emergency drill scenario is witnessed and graded by the NRC and state inspectors, with full participation by the fire department and the local hospital. Radiation Safety Officer (RSO) is in charge of all radiological aspects of the facility, and reports to the plant manager directly. The RSO or any of his staff has the authority to stop a job if there is a radiological concern. The Radiation protection organization interfaces with Production, QA and Engineering and ensures there is no conflict with Industrial Safety, OSHA and FDA requirements. Any employee has the right to call the regulatory officials if he/she has a concern. Operational aspects of Radiation protection program such as radiological survey, contamination control and limits, air sample survey, radio active waste processing and record retention requirements are per plant procedures and regulatory requirements. Shielding and administrative requirements for designing a modification to an existing design or a new lab/hot cell is subject to in-depth review and approval by Radiation Safety Committee. Each department has a Dose Reduction Subcommittee which meets periodically to discuss if any changes in procedures or facility can be made to decrease the dose. The subcommittee also trends the dose to ensure it is trending downward. Even though 99 Mo/ 99m TC generators are manufactured at the facility, majority of the dose is from cyclotron maintenance

  2. Respiratory mechanics to understand ARDS and guide mechanical ventilation.

    Science.gov (United States)

    Mauri, Tommaso; Lazzeri, Marta; Bellani, Giacomo; Zanella, Alberto; Grasselli, Giacomo

    2017-11-30

    As precision medicine is becoming a standard of care in selecting tailored rather than average treatments, physiological measurements might represent the first step in applying personalized therapy in the intensive care unit (ICU). A systematic assessment of respiratory mechanics in patients with the acute respiratory distress syndrome (ARDS) could represent a step in this direction, for two main reasons. Approach and Main results: On the one hand, respiratory mechanics are a powerful physiological method to understand the severity of this syndrome in each single patient. Decreased respiratory system compliance, for example, is associated with low end expiratory lung volume and more severe lung injury. On the other hand, respiratory mechanics might guide protective mechanical ventilation settings. Improved gravitationally dependent regional lung compliance could support the selection of positive end-expiratory pressure and maximize alveolar recruitment. Moreover, the association between driving airway pressure and mortality in ARDS patients potentially underlines the importance of sizing tidal volume on respiratory system compliance rather than on predicted body weight. The present review article aims to describe the main alterations of respiratory mechanics in ARDS as a potent bedside tool to understand severity and guide mechanical ventilation settings, thus representing a readily available clinical resource for ICU physicians.

  3. Use of certification programs in the radiological protection of the patient

    International Nuclear Information System (INIS)

    Lucino, Sergio; Touzet, Rodolfo

    2008-01-01

    Full text: One of the main recommendations of the Congress of Malaga on Radiological Protection of the Patient is 'the qualification and training of the staff'. This goal cannot be reached in a country, in complete and systematic form, without the help of existing national programs who allow designing a program of continuous development of the professional capacities. This program must be able to adapt in permanent form to the needs of the Program of Radiological Protection of the Patient that change and evolve in constant form. In case of the Argentina it was adapted to these needs the 'National Program of Certification and Re-certification of medical professionals in Radiology and Radio-Diagnosis'. On the base of the existing program, general requirements were established for the radiological protection of the patient and in addition, special requirements for four specialties: a) General and pediatrics radiology; b) Computed tomography; c) Interventional radiology; d) Radiotherapy. The National Program of Certification was established in 1997 with a 'Top Permanent Council' formed by the National Minister of Health advised by a scientific council. It was also creates the 'National Council of Certification and professional Re-certification' integrated by the Minister of Education, the National Academy of Medicine, the Faculties of Medicine of the whole country, the medical Federations, the trade-union Associations and the Argentine Medical Association. The process of certification can be delegated to academic or university entities, medical colleges and medical chambers that have been recognized path and ethical conduct. The certification is voluntary but it becomes obligatory to be recognized as a specialist. The certification has duration of 5 years and is renewable on the basis of a system of credits that considers different elements of the developed activities and the written theoretical and practical evaluations. It is a transparent process where the ethical

  4. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 05: A novel respiratory motion simulation program for VMAT treatment plans: a phantom validation study

    Energy Technology Data Exchange (ETDEWEB)

    Hubley, Emily; Pierce, Greg; Ploquin, Nicolas [University of Calgary, Tom Baker Cancer Centre, Tom Baker Cancer Centre (Canada)

    2016-08-15

    Purpose: To develop and validate a computational method to simulate craniocaudal respiratory motion in a VMAT treatment plan. Methods: Three 4DCTs of the QUASAR respiratory motion phantom were acquired with a 2cm water-density spherical tumour embedded in cedar to simulate lung. The phantom was oscillating sinusoidally with an amplitude of 2cm and periods of 3, 4, and 5 seconds. An ITV was contoured and 5mm PTV margin was added. High and a low modulation factor VMAT plans were created for each scan. An in-house program was developed to simulate respiratory motion in the treatment plans by shifting the MLC leaf positions relative to the phantom. Each plan was delivered to the phantom and the dose was measured using Gafchromic film. The measured and calculated plans were compared using an absolute dose gamma analysis (3%/3mm). Results: The average gamma pass rate for the low modulation plan and high modulation plans were 91.1% and 51.4% respectively. The difference between the high and low modulation plans gamma pass rates is likely related to the different sampling frequency of the respiratory curve and the higher MLC leaf speeds in the high modulation plan. A high modulation plan has a slower gantry speed and therefore samples the breathing cycle at a coarser frequency leading to inaccuracies between the measured and planned doses. Conclusion: A simple program, including a novel method for increasing sampling frequency beyond the control point frequency, has been developed to simulate respiratory motion in VMAT plans by shifting the MLC leaf positions.

  5. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 05: A novel respiratory motion simulation program for VMAT treatment plans: a phantom validation study

    International Nuclear Information System (INIS)

    Hubley, Emily; Pierce, Greg; Ploquin, Nicolas

    2016-01-01

    Purpose: To develop and validate a computational method to simulate craniocaudal respiratory motion in a VMAT treatment plan. Methods: Three 4DCTs of the QUASAR respiratory motion phantom were acquired with a 2cm water-density spherical tumour embedded in cedar to simulate lung. The phantom was oscillating sinusoidally with an amplitude of 2cm and periods of 3, 4, and 5 seconds. An ITV was contoured and 5mm PTV margin was added. High and a low modulation factor VMAT plans were created for each scan. An in-house program was developed to simulate respiratory motion in the treatment plans by shifting the MLC leaf positions relative to the phantom. Each plan was delivered to the phantom and the dose was measured using Gafchromic film. The measured and calculated plans were compared using an absolute dose gamma analysis (3%/3mm). Results: The average gamma pass rate for the low modulation plan and high modulation plans were 91.1% and 51.4% respectively. The difference between the high and low modulation plans gamma pass rates is likely related to the different sampling frequency of the respiratory curve and the higher MLC leaf speeds in the high modulation plan. A high modulation plan has a slower gantry speed and therefore samples the breathing cycle at a coarser frequency leading to inaccuracies between the measured and planned doses. Conclusion: A simple program, including a novel method for increasing sampling frequency beyond the control point frequency, has been developed to simulate respiratory motion in VMAT plans by shifting the MLC leaf positions.

  6. PROGRAM RATIONALE OF TREATMENT AND PREVENTION IN CHILDREN WITH FREQUENT RESPIRATORY DISEASES

    Directory of Open Access Journals (Sweden)

    A. V. Deryusheva

    2017-01-01

    Full Text Available The results of complex clinical and laboratory examination of 146 children aged 2—3 years attending kindergarten were presented. The leading predictors of frequent respiratory disease: disturbance of microbiocenosis oropharyngeal mucosa, immunoglobulins decrease, respiratory allergic pathology were established and scientifically substantiated. The results obtained prove the main directions of therapeutic and preventive measures.

  7. Creating a More Responsive and Seamless Refugee Protection System: The Scope, Promise and Limitations of US Temporary Protection Programs

    Directory of Open Access Journals (Sweden)

    Donald Kerwin

    2014-04-01

    Full Text Available Temporary protection programs can provide haven to endangered persons while states and non-governmental organizations (NGOs work to create durable solutions in sending, host and third countries.[1] They have the potential to further the interests of forced migrants in protection, states in effective and coordinated migration management, and the international community in solidarity.US temporary protection programs rest primarily on executive discretion and have not been substantially revisited for nearly 25 years. “Parole” represents the primary vehicle for temporarily admitting non-citizens for emergency and humanitarian reasons.[2]  Prior to 1980, the United States used parole to admit large refugee and refugee-like populations to whom (in most cases it later extended lawful permanent resident (LPR status. The 1980 Refugee Act made the US refugee resettlement program the primary vehicle for refugee admissions, limited the use of parole to individuals (not groups, and created a presumption against granting parole to refugees.The United States provides immigrant (permanent visas to abused, neglected and abandoned children, as well as to certain Iraqis and Afghanis who worked for the US military or for military contractors.  It can also award up to 5,000 non-immigrant (temporary “T” visas each year to victims of human trafficking and up to 10,000 non-immigrant “U” visas to survivors of crime who assist law enforcement officials in investigating and prosecuting crimes. However, since 1980, the United States has lacked a dedicated legal vehicle for admitting other refugee-like populations.Temporary protected status (TPS applies to non-citizens from states experiencing  armed conflict, the aftermath of natural disaster, or other extraordinary, temporary conditions that make it unsafe to return. The TPS statute allows the Secretary of the US Department of Homeland Security (DHS to designate states or regions within states for TPS

  8. Lessons learned at TMI: cleanup for respiratory protection

    International Nuclear Information System (INIS)

    Parfitt, B.A.; Gee, E.F.

    1987-01-01

    The March 28, 1979, accident at Three Mile Island Unit 2 (TMI-2) presented GPU Nuclear with technical challenges unprecedented in the nuclear power industry. Among these challenges were a myriad of health physics problems that had to be solved to ensure a radiologically safe environment for workers performing cleanup activities. The application of the as-low-as-reasonably-achievable (ALARA) philosophy has been a fundamental aspects in protecting cleanup workers. The unique conditions produced by the accident, however, have necessitated novel and innovative approaches in making this philosophy effective. The option to use respirators is based on which method will result in the lowest radiation dose to the worker. Inherent to this program has been the training of workers to overcome the perception that any internal contamination is of foremost concern and is orders of magnitude greater in biological effect than an identical external dose. It is, of course, the total dose (internal dose plus external dose) that must be minimized to implement a true ALARA philosophy. The need for considering the total radiation dose when making decisions to use respirators has been clear during the TMI-2 cleanup. Prescribing respirators is not always good for the ALARA concept

  9. The study protocol for a randomized controlled trial of a family-centred tobacco control program about environmental tobacco smoke (ETS to reduce respiratory illness in Indigenous infants

    Directory of Open Access Journals (Sweden)

    Segan Catherine

    2010-03-01

    Full Text Available Abstract Background Acute respiratory illness (ARI is the most common cause of acute presentations and hospitalisations of young Indigenous children in Australia and New Zealand (NZ. Environmental tobacco smoke (ETS from household smoking is a significant and preventable contributor to childhood ARI. This paper describes the protocol for a study which aims to test the efficacy of a family-centred tobacco control program about ETS to improve the respiratory health of Indigenous infants in Australia and New Zealand. For the purpose of this paper 'Indigenous' refers to Australia's Aboriginal and Torres Strait Islander peoples when referring to Australian Indigenous populations. In New Zealand, the term 'Indigenous' refers to Māori. Methods/Design This study will be a parallel, randomized, controlled trial. Participants will be Indigenous women and their infants, half of whom will be randomly allocated to an 'intervention' group, who will receive the tobacco control program over three home visits in the first three months of the infant's life and half to a control group receiving 'usual care' (i.e. they will not receive the tobacco control program. Indigenous health workers will deliver the intervention, the goal of which is to reduce or eliminate infant exposure to ETS. Data collection will occur at baseline (shortly after birth and when the infant is four months and one year of age. The primary outcome is a doctor-diagnosed, documented case of respiratory illness in participating infants. Discussion Interventions aimed at reducing exposure of Indigenous children to ETS have the potential for significant benefits for Indigenous communities. There is currently a dearth of evidence for the effect of tobacco control interventions to reduce children's exposure to ETS among Indigenous populations. This study will provide high-quality evidence of the efficacy of a family-centred tobacco control program on ETS to reduce respiratory illness. Outcomes of

  10. Impacts on power reactor health physics programs

    International Nuclear Information System (INIS)

    Meyer, B.A.

    1991-01-01

    The impacts on power reactor health physics programs form implementing the revised 10 CFR Part 20 will be extensive and costly. Every policy, program, procedure and training lesson plan involving health physics will require changes and the subsequent retraining of personnel. At each power reactor facility, hundreds of procedures and thousands of people will be affected by these changes. Every area of a power reactor health physics program will be affected. These areas include; ALARA, Respiratory Protection, Exposure Control, Job Coverage, Dosimetry, Radwaste, Effluent Accountability, Emergency Planning and Radiation Worker Training. This paper presents how power reactor facilities will go about making these changes and gives possible examples of some of these changes and their impact on each area of power reactor health physics program

  11. Training program in radiation protection: implantation in a radiation oncology department

    International Nuclear Information System (INIS)

    Chretien, Mario; Morrier, Janelle; Cote, Carl; Lavallee, Marie C.

    2008-01-01

    Full text: Purpose: To introduce the radiation protection training program implemented in the radiation oncology department of the Hotel-Dieu de Quebec. This program seeks to provide an adequate training for all the clinic workers and to fulfill Canadian Nuclear Safety Commission's (CNSC) legislations. Materials and Methods: The radiation protection training program implemented is based on the use of five different education modalities: 1) Oral presentations, when the objective of the formation is to inform a large number of persons about general topics; 2) Periodic journals are published bimonthly and distributed to members of the department. They aim to answer frequently asked questions on the radiation safety domain. Each journal contains one main subject which is vulgarized and short notices, these later added to inform the readers about the departmental news and developments in radiation safety; 3) Electronic self-training presentations are divided into several units. Topics, durations, complexity and evaluations are adapted for different worker groups; 4) Posters are strategically displayed in the department in order to be read by all the radiation oncology employees, even those who are not specialized in the radiation protection area; 5) Simulations are organized for specialised workers to practice and to develop their skills in radiation protection situations as emergencies. A registration method was developed to record all training performed by each member of the department. Results: The training program implemented follows the CNSC recommendations. It allows about 150 members of the department to receive proper radiation safety training. The oral presentations allow an interaction between the trainer and the workers. The periodic journals are simple to write while ensuring continuous training. They are also easy to read and to understand. The e-learning units and their associated evaluations can be done at any time and everywhere in the department. The

  12. Evaluation of respiratory pattern during respiratory-gated radiotherapy

    International Nuclear Information System (INIS)

    Dobashi, Suguru; Mori, Shinichiro

    2014-01-01

    The respiratory cycle is not strictly regular, and generally varies in amplitude and period from one cycle to the next. We evaluated the characteristics of respiratory patterns acquired during respiratory gating treatment in more than 300 patients. A total 331 patients treated with respiratory-gated carbon-ion beam therapy were selected from a group of patients with thoracic and abdominal conditions. Respiratory data were acquired for a total of 3,171 fractions using an external respiratory sensing monitor and evaluated for respiratory cycle, duty cycle, magnitude of baseline drift, and intrafractional/interfractional peak inhalation/exhalation positional variation. Results for the treated anatomical sites and patient positioning were compared. Mean ± SD respiratory cycle averaged over all patients was 4.1 ± 1.3 s. Mean ± SD duty cycle averaged over all patients was 36.5 ± 7.3 %. Two types of baseline drift were seen, the first decremental and the second incremental. For respiratory peak variation, the mean intrafractional variation in peak-inhalation position relative to the amplitude in the first respiratory cycle (15.5 ± 9.3 %) was significantly larger than that in exhalation (7.5 ± 4.6 %). Interfractional variations in inhalation (17.2 ± 18.5 %) were also significantly greater than those in exhalation (9.4 ± 10.0 %). Statistically significant differences were observed between patients in the supine position and those in the prone position in mean respiratory cycle, duty cycle, and intra-/interfractional variations. We quantified the characteristics of the respiratory curve based on a large number of respiratory data obtained during treatment. These results might be useful in improving the accuracy of respiratory-gated treatment.

  13. Implementation of smoke-free legislation in Malaysia: are adolescents protected from respiratory health effects?

    Science.gov (United States)

    Zulkifli, Aziemah; Abidin, Najihah Zainol; Abidin, Emilia Zainal; Hashim, Zailina; Rahman, Anita Abd; Rasdi, Irniza; Syed Ismail, Sharifah Norkhadijah; Semple, Sean

    2014-01-01

    This study aimed to examine the relationship between respiratory health of Malaysian adolescents with secondhand smoke (SHS) exposure and smoke-free legislation (SFL) implementation. A total of 898 students from 21 schools across comprehensive- and partial-SFL states were recruited. SHS exposures and respiratory symptoms were assessed via questionnaire. Prenatal and postnatal SHS exposure information was obtained from parental-completed questionnaire. The prevalence of respiratory symptoms was: 11.9% ever wheeze, 5.6% current wheeze, 22.3% exercise-induced wheeze, 12.4% nocturnal cough, and 13.1% self-reported asthma. SHS exposure was most frequently reported in restaurants. Hierarchical logistic regression indicates living in a comprehensive-SFL state was not associated with a lower risk of reporting asthma symptoms. SHS exposure in public transport was linked to increased risk for wheeze (Adjusted Odds Ratio (AOR) 16.6; 95%confidence interval (CI), 2.69-101.7) and current wheezing (AOR 24.6; 95%CI, 3.53-171.8). Adolescents continue to be exposed to SHS in a range of public venues in both comprehensive- and partial-SFL states. Respiratory symptoms are common among those reporting SHS exposure on public transportation. Non-compliance with SFL appears to be frequent in many venues across Malaysia and enforcement should be given priority in order to reduce exposure.

  14. Combining Primary Prevention and Risk Reduction Approaches in Sexual Assault Protection Programming

    Science.gov (United States)

    Menning, Chadwick; Holtzman, Mellisa

    2015-01-01

    Objective: The object of this study is to extend prior evaluations of Elemental, a sexual assault protection program that combines primary prevention and risk reduction strategies within a single program. Participants and Methods: During 2012 and 2013, program group and control group students completed pretest, posttest, and 6-week and 6-month…

  15. Monitoring of pulmonary mechanics in acute respiratory distress syndrome to titrate therapy.

    Science.gov (United States)

    Gattinoni, Luciano; Eleonora, Carlesso; Caironi, Pietro

    2005-06-01

    This paper reviews recent findings regarding the respiratory mechanics during acute respiratory distress syndrome as a tool for tailoring its ventilatory management. The pressure-volume curve has been used for many years as a descriptor of the respiratory mechanics in patients affected by acute respiratory distress syndrome. The use of the sigmoidal equation introduced by Venegas for the analysis of the pressure-volume curve seems to be the most rigorous mathematical approach to assessing lung mechanics. Increasing attention has been focused on the deflation limb for titration of positive end-expiratory pressure. Based on physiologic reasoning, a novel parameter, the stress index, has been proposed for tailoring a safe mechanical ventilation, although its clinical impact has still to be proved. Evidence has confirmed that a variety of underlying pathologies may lead to acute respiratory distress syndrome, making unrealistic any attempt to unify the ventilatory approach. Although extensively proposed to tailor mechanical ventilation during acute respiratory distress syndrome, there is no evidence that the pressure-volume curve may be useful in setting a lung-protective strategy in the presence of different potentials for recruitment. The Venegas approach should be the standard analysis of pressure-volume curves. In any patient, the potential for recruitment should be assessed, as a basis for tailoring the most effective mechanical ventilation. Further studies are needed to clarify the potential use of the pressure-volume curve to guide a lung-protective ventilatory strategy.

  16. Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure

    NARCIS (Netherlands)

    Kneyber, Martin C. J.; van Heerde, Marc; Twisk, Jos W. R.; Plotz, Frans B.; Markhors, Dick G.

    2009-01-01

    Introduction Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of

  17. Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure

    NARCIS (Netherlands)

    Kneijber, M.C.J.; van Heerde, M.; Twisk, J.W.R.; Plotz, F.; Markhorst, D.G.

    2009-01-01

    Introduction: Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of

  18. Respiratory tract infection during Hajj

    Directory of Open Access Journals (Sweden)

    Alzeer Abdulaziz

    2009-01-01

    Full Text Available Respiratory tract infection during Hajj (pilgrimage to Mecca is a common illness, and it is responsible for most of the hospital admissions. Influenza virus is the leading cause of upper respiratory tract infection during Hajj, and pneumonia can be serious. Taking into account the close contacts among the pilgrims, as well as the crowding, the potential for transmission of M. tuberculosis is expected to be high. These pilgrims can be a source for spreading infection on their return home. Although vaccination program for influenza is implemented, its efficacy is uncertain in this religious season. Future studies should concentrate on prevention and mitigation of these infections.

  19. Workplace protection of air-fed visors used in paint spraying operations.

    Science.gov (United States)

    Bolsover, J; Rajan-Sithamparanadarajah, B; Vaughan, N

    2006-04-01

    Air-fed visors are commonly used for protection against exposure to airborne isocyanates during paint spraying. Protection levels for this class of equipment are theoretically adequate, yet isocyanate sensitization in this occupation still occurs. The work reported here set out to establish the level of respiratory protection that is achieved during real paint spraying activities when air-fed visors are used. The work also examined the effects of reduced air supply flow rates on this type of respiratory protection. The workplace study highlighted common problems that occur when attempting to measure protection factors, and process and interpret the collected data. Many of the environments included in this study did not exhibit challenge concentrations high enough to reliably measure the workplace protection factor of this class of device. When detection limits are taken into consideration, the remaining field data suggest that an assigned protection factor in the region of 40 may be appropriate. When well maintained and used in accordance with the manufacturer's instructions, air-fed visors are capable of providing a good level of respiratory protection. The protection given by air-fed visors is strongly dependent on the air flow supplied to them. Laboratory measurements demonstrate that protection falls as the air supply falls. This is a gradual process and does not suddenly occur at any particular air supply flow. Observations made during the field tests indicate that there may be other activities associated with the spraying process that need to be taken into consideration when looking for sources of respiratory sensitization.

  20. PROPHYLACTIC ADMINISTRATION OF RESPIRATORY SYNCYTIAL VIRUS IMMUNE GLOBULIN TO HIGH-RISK INFANTS AND YOUNG-CHILDREN

    NARCIS (Netherlands)

    GROOTHUIS, [No Value; SIMOES, EAF; LEVIN, MJ; HALL, CB; LONG, CE; RODRIGUEZ, WJ; ARROBIO, J; MEISSNER, HC; FULTON, DR; WELLIVER, RC; TRISTRAM, DA; SIBER, GR; PRINCE, GA; VANRADEN, M; HEMMING, VG

    1993-01-01

    Background. Infants with cardiac disease or prematurity are at risk for severe illness caused by respiratory syncytial virus. Immune globulin with a high titer of antibodies against respiratory syncytial virus may offer infants and young children at risk protection from this serious, common

  1. Evaluation of exercise-respiratory system modifications and integration schemes for physiological systems

    Science.gov (United States)

    Gallagher, R. R.

    1974-01-01

    Exercise subroutine modifications are implemented in an exercise-respiratory system model yielding improvement of system response to exercise forcings. A more physiologically desirable respiratory ventilation rate in addition to an improved regulation of arterial gas tensions and cerebral blood flow is observed. A respiratory frequency expression is proposed which would be appropriate as an interfacing element of the respiratory-pulsatile cardiovascular system. Presentation of a circulatory-respiratory system integration scheme along with its computer program listing is given. The integrated system responds to exercise stimulation for both nonstressed and stressed physiological states. Other integration possibilities are discussed with respect to the respiratory, pulsatile cardiovascular, thermoregulatory, and the long-term circulatory systems.

  2. Radiation protection program for assistance of victims of radiation accidents

    International Nuclear Information System (INIS)

    Fajardo, P.W.; Costa Silva, L.H. da; Rosa, R.

    1991-11-01

    The principles aspects of a radiological protection program for hospitals in case of medical assistance to external and internal contaminated persons are showed. It is based on the experience obtained at Centro Medico Naval Marcilio Dias during the assistance to the victims of Goiania accident in 1987. This paper describes the basic infrastructure of a nursery and the radiation protection procedures for the access control of people and materials, area and personal monitoring, decontamination and the support activities such as calibration of radiation monitors and waste management. Is is also estimated the necessary radiation protection materials and the daily quantity of waste generated. (author)

  3. Distance Education Programs in Radiation Protection- A ten year Review

    International Nuclear Information System (INIS)

    Gauvin, J. P.

    2004-01-01

    Professional development has always played a critical role in the organisation of radiation safety programs. Training programs for professionals, technologists and general workers involved in high risk trades vary according to their experience and specific functions. The key concept for effective programs consists in the proper match of the training content with the individual skills and interests of the participants. In conventional class training, unless the students constitute an homogeneous group, the teaching can not perfectly follow the specific needs of all participants and the pace of the course is kept at a sub-optimal level in order to accommodate less talented participants. Distance education with Electronic Mail, web CT, first class mail, and other communication tools has been used with success during the last decade in undergraduate, master's and doctoral programs as well as in continuing training for workers. It offers a wide range of teaching strategies and course content. Compared to conventional training, it has numerous benefits: (1) Travel costs for students and instructors are eliminated and international groups of students and professors can easily be constituted; (2) Instructors can be recruited worldwide; (3) Discussion forums can be established easily; (4) Integration of expert guests into online course discussions are possible; (5) Student online publications of projects, assignments and abstracts are current; (6) Schedules are more flexible and proctored examinations are possible. The author will present the strategies used at McGill University in the teaching of Radiation Protection to physicians and professionals ( MSc. level ) and the application of distance education methods for training large groups of workers in biomedical research centres, hospitals, power generation facilities and utilities in general. He will describe the content of the programs, the study guides, the evaluation formats, web-site references and resources, the

  4. Dosimetry of the respiratory tract

    International Nuclear Information System (INIS)

    Roy, M.

    1996-01-01

    A new dosimetric model of the human respiratory tract has been recently recommended by the International Commission on Radiological Protection, in ICRP Publication 66. This model was intended to update the previous lung model of the Task Group on Lung Dynamics that was adopted by ICRP in Publication 30. With this aim, extensive reviews of the available knowledge were made for anatomy and physiology of the respiratory tract and for deposition, clearance and biological effects of inhaled radionuclides. Finally, expanded dosimetry requirements resulted in a widely different approach from the former model. The main features of the new model are the followings: instead of calculating the average dose to the total mass of blood filled lung, the model takes account of differences in radiosensitivity of the venous respiratory tract tissues. It applies not only to adult workers but also to all members of the population, and provides reference values for children aged 3 months, 1, 5, 10, and 15 years, and adults. Deposition modelling of airborne gases and aerosols associates age dependent breathing rates, airway dimensions and physical activity, to particle size, density and chemical form of inhaled material. Clearance results of competition between mechanical transport clearance and absorption to blood. At each step of the calculation, adjustment guidance is provided to account for use of exact values of particle sizes and specific dissolution rates of inhaled material in order to calculate their own parameter of retention in the airways, and to assess accurately doses to the respiratory tract. Possible influence of smoking, of respiratory tract diseases and of eventual exposure to airborne toxicants is also addressed. (author)

  5. Successful topical respiratory tract immunization of primates against Ebola virus.

    Science.gov (United States)

    Bukreyev, Alexander; Rollin, Pierre E; Tate, Mallory K; Yang, Lijuan; Zaki, Sherif R; Shieh, Wun-Ju; Murphy, Brian R; Collins, Peter L; Sanchez, Anthony

    2007-06-01

    Ebola virus causes outbreaks of severe viral hemorrhagic fever with high mortality in humans. The virus is highly contagious and can be transmitted by contact and by the aerosol route. These features make Ebola virus a potential weapon for bioterrorism and biological warfare. Therefore, a vaccine that induces both systemic and local immune responses in the respiratory tract would be highly beneficial. We evaluated a common pediatric respiratory pathogen, human parainfluenza virus type 3 (HPIV3), as a vaccine vector against Ebola virus. HPIV3 recombinants expressing the Ebola virus (Zaire species) surface glycoprotein (GP) alone or in combination with the nucleocapsid protein NP or with the cytokine adjuvant granulocyte-macrophage colony-stimulating factor were administered by the respiratory route to rhesus monkeys--in which HPIV3 infection is mild and asymptomatic--and were evaluated for immunogenicity and protective efficacy against a highly lethal intraperitoneal challenge with Ebola virus. A single immunization with any construct expressing GP was moderately immunogenic against Ebola virus and protected 88% of the animals against severe hemorrhagic fever and death caused by Ebola virus. Two doses were highly immunogenic, and all of the animals survived challenge and were free of signs of disease and of detectable Ebola virus challenge virus. These data illustrate the feasibility of immunization via the respiratory tract against the hemorrhagic fever caused by Ebola virus. To our knowledge, this is the first study in which topical immunization through respiratory tract achieved prevention of a viral hemorrhagic fever infection in a primate model.

  6. Respiratory viruses in young South African children with acute lower respiratory infections and interactions with HIV.

    Science.gov (United States)

    Annamalay, Alicia A; Abbott, Salome; Sikazwe, Chisha; Khoo, Siew-Kim; Bizzintino, Joelene; Zhang, Guicheng; Laing, Ingrid; Chidlow, Glenys R; Smith, David W; Gern, James; Goldblatt, Jack; Lehmann, Deborah; Green, Robin J; Le Souëf, Peter N

    2016-08-01

    Human rhinovirus (RV) is the most common respiratory virus and has been associated with frequent and severe acute lower respiratory infections (ALRI). The prevalence of RV species among HIV-infected children in South Africa is unknown. To describe the prevalence of respiratory viruses, including RV species, associated with HIV status and other clinical symptoms in children less than two years of age with and without ALRI in Pretoria, South Africa. Nasopharyngeal aspirates were collected from 105 hospitalized ALRI cases and 53 non-ALRI controls less than two years of age. HIV status was determined. Common respiratory viruses were identified by PCR, and RV species and genotypes were identified by semi-nested PCR, sequencing and phylogenetic tree analyses. Respiratory viruses were more common among ALRI cases than controls (83.8% vs. 69.2%; p=0.041). RV was the most commonly identified virus in cases with pneumonia (45.6%) or bronchiolitis (52.1%), regardless of HIV status, as well as in controls (39.6%). RV-A was identified in 26.7% of cases and 15.1% of controls while RV-C was identified in 21.0% of cases and 18.9% of controls. HIV-infected children were more likely to be diagnosed with pneumonia than bronchiolitis (pinfected cases (n=15) compared with 30.6% of HIV-uninfected cases (n=85, p=0.013), and was identified more frequently in bronchiolitis than in pneumonia cases (43.8% vs. 12.3%; pinfection may be protective against RSV and bronchiolitis. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Indigenous Respiratory Outreach Care: the first 18 months of a specialist respiratory outreach service to rural and remote Indigenous communities in Queensland, Australia.

    Science.gov (United States)

    Medlin, Linda G; Chang, Anne B; Fong, Kwun; Jackson, Rebecca; Bishop, Penny; Dent, Annette; Hill, Deb C; Vincent, Stephen; O'Grady, Kerry-Ann F

    2014-09-01

    Respiratory diseases are a leading cause of morbidity and mortality in Indigenous Australians. However, there are limited approaches to specialist respiratory care in rural and remote communities that are culturally appropriate. A specialist Indigenous Respiratory Outreach Care (IROC) program, developed to address this gap, is described. The aim of the present study was to implement, pilot and evaluate multidisciplinary specialist respiratory outreach medical teams in rural and remote Indigenous communities in Queensland, Australia. Sites were identified based on a perception of unmet need, burden of respiratory disease and/or capacity to use the clinical service and capacity building for support offered. IROC commenced in March 2011 and, to date, has been implemented in 13 communities servicing a population of approximately 43000 Indigenous people. Clinical service delivery has been possible through community engagement and capacity building initiatives directed by community protocols. IROC is a culturally sensitive and sustainable model for adult and paediatric specialist outreach respiratory services that may be transferrable to Indigenous communities across Queensland and Australia.

  8. WI-CERFP Respiratory Protection Optimization: A Detailed Analysis

    Science.gov (United States)

    2015-12-01

    Protection, “M50” http://www.avon-protection.com/ products /m50.htm, Accessed 14 Dec 2015. 17 Factor 3: Cost for Initial Purchase The Avon M50 APR, IRT...seal, the air inside the mask is “ cleaner ”. The output of the test is a ratio of dirty air to clean air, with a minimum value required to be

  9. The Voivodeship’s Program of Malopolska Heritage and Cultural Landscape Protection

    Directory of Open Access Journals (Sweden)

    JÓZEF HERNIK

    2007-01-01

    Full Text Available The main goal in the field of landscape management includes the protection and improvement of landscapes’ condition and departing from their degradation. This goal is included in the European Landscape Convention. Its aim is to care for continent’s landscapes through the processes such as identification, evaluation, protection, management, and planning. The Convention is to apply to all landscapes, not only to the landscapes of a unique value such as national parks or to the landscapes that are on the List of World Heritage UNESCO. The article includes the analysis of the Voivodeship’s Program of Malopolska Heritage and Cultural Landscape Protection from the point of view of the Convention. Due to the fact that Poland has ratified this Convention, certain responsibilities follow. On voivodeship’s level, the Voivodeship’s Program should be recognized as a device to carry out the policy in the field of landscape in accordance with Article 1 of the Convention.

  10. Impact of the probability of causation on the radiation protection program

    International Nuclear Information System (INIS)

    Meinhold, C.B.

    1988-01-01

    Although the probability of causation approach is the only scientific basis on which a given cancer can be judged to be causally related to a given exposure, the impact of this concept on the radiation safety program could be counter-productive. As health physicists, the practices and the concepts we employ have been developed to protect the worker. Effective dose equivalent and committed dose equivalent are protective concepts but useless for probability of causation analysis. Perhaps extensive records will be the only way that good radiation protection and probability of causation analysis can coexist

  11. Ultra-protective tidal volume: how low should we go?

    OpenAIRE

    Costa, Eduardo LV; Amato, Marcelo BP

    2013-01-01

    Applying tidal volumes of less than 6 mL/kg might improve lung protection in patients with acute respiratory distress syndrome. In a recent article, Retamal and colleagues showed that such a reduction is feasible with conventional mechanical ventilation and leads to less tidal recruitment and overdistension without causing carbon dioxide retention or auto-positive end-expiratory pressure. However, whether the compensatory increase in the respiratory rate blunts the lung protection remains une...

  12. The R+D radiological protection program in the European Communities

    International Nuclear Information System (INIS)

    Mingot Buades, F.

    1993-01-01

    The R+D program a radiological protection for the year 1992 has lied basically on three areas: I .- Radiological exposure of man II .- Radiation effects on man (evaluation, prevention and treatment) III.- Risks and management of radiation exposure

  13. Some problems in the acceptability of implementing radiation protection programs

    International Nuclear Information System (INIS)

    Neill, R.H.

    1997-01-01

    The three fundamentals that radiation protection programs are based upon are; 1) establishing a quantitative correlation between radiation exposure and biological effects in people; 2) determining a level of acceptable risk of exposure; and 3) establishing systems to measure the radiation dose to insure compliance with the regulations or criteria. The paper discusses the interrelationship of these fundamentals, difficulties in obtaining a consensus of acceptable risk and gives some examples of problems in identifying the most critical population-at-risk and in measuring dose. Despite such problems, it is recommended that we proceed with the existing conservative structure of radiation protection programs based upon a linear no threshold model for low radiation doses to insure public acceptability of various potential radiation risks. Voluntary compliance as well as regulatory requirements should continue to be pursued to maintain minimal exposure to ionizing radiation. (author)

  14. A radiation protection training program with a focus on communicating risk

    International Nuclear Information System (INIS)

    Clement, C.H.; Zelmer, R.L.; Tourneur, F.

    2000-01-01

    Radiation protection training is generally provided to promote a radiologically safe work environment, and to help ensure that doses are kept as low as reasonably achievable. In many cases, this reason makes good sense. Radiological risk can often be a significant concern when working with radioactive materials or radiation-emitting devices. However, in conducting the work of the Low-Level Radioactive Waste Management Office, it is often the case that the perception of radiological risk is of greater concern that the radiological risk itself. In this case, radiation protection training can serve another equally important purpose. It can be used to convey, in a balanced manner, the actual radiological risks associated with the work, and to put those risks in perspective. For individuals who are not familiar with radiation safety, effective radiation protection training that focuses on risk communication can reduce the level of concern surrounding work to be performed. This, in turn, can have an overall positive impact on the efficiency of the work, on goodwill within the community where the work is taking place, and even on the overall safety of those conducting the work. The radiation protection training program developed and implemented by the Low-Level Radioactive Waste Management Office is described in the context of other, more traditional radiation protection training programs. (author)

  15. [Effectiveness of an educational program for respiratory rehabilitation of Chronic Obstructive Pulmonary Disease patients in Primary Care in improving the quality of life, symptoms, and clinical risk].

    Science.gov (United States)

    Blánquez Moreno, Cristina; Colungo Francia, Cristina; Alvira Balada, M Carme; Kostov, Belchin; González-de Paz, Luis; Sisó-Almirall, Antoni

    2017-10-04

    To determine the impact of an educational program to improve the management of chronic obstructive pulmonary disease (COPD) that contributes to an increase of the quality of life, exercise capacity, level of dyspnoea, and clinical risk. Intervention study without controls. Primary Healthcare Centre. 193 patients with COPD were invited, 73 accepted and 55 participated in the educational program. Respiratory rehabilitation educational program with basic concepts of pulmonary and respiratory pathophysiology, respiratory physiotherapy exercises, practical workshop on the use of the most frequent inhalation devices, understanding of chronic disease and self-care measures in case of exacerbation. The quality of life (the COPD assessment test), exercise tolerance (the Six-Minute Walk Test), rating of perceived exertion (Borg Dyspnoea Score) and clinical risk (BODE index) were assessed by means of validated questionnaires in Spanish. A total of 43 (78.2%) participants completed the program. An improvement in the quality of life by a mean of 3.3 points was observed (95%CI; 1.76-4.84). Just over half (53.5%) of the participants obtained a clinically relevant improvement. Participants also improved their physical exercise capacity at post-intervention by increasing the distance that they walked in 6min by a mean of 20.76m (95%CI; 2.57-38.95). Improvements in the level of dyspnoea and clinical risk were also observed. The educational program shows a statistically significant and clinically relevant improvement in the quality of life, fatigue, symptomatology, exercise capacity, level of dyspnoea, and clinical risk. The program is adaptable to the health care routine of healthcare centres. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  16. Respiratory source control using a surgical mask: An in vitro study.

    Science.gov (United States)

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  17. Respiratory and oral vaccination improves protection conferred by the live vaccine strain against pneumonic tularemia in the rabbit model.

    Science.gov (United States)

    Stinson, Elizabeth; Smith, Le'Kneitah P; Cole, Kelly Stefano; Barry, Eileen M; Reed, Douglas S

    2016-10-01

    Tularemia is a severe, zoonotic disease caused by a gram-negative bacterium, Francisella tularensis We have previously shown that rabbits are a good model of human pneumonic tularemia when exposed to aerosols containing a virulent, type A strain, SCHU S4. We further demonstrated that the live vaccine strain (LVS), an attenuated type B strain, extended time to death when given by scarification. Oral or aerosol vaccination has been previously shown in humans to offer superior protection to parenteral vaccination against respiratory tularemia challenge. Both oral and aerosol vaccination with LVS were well tolerated in the rabbit with only minimal fever and no weight loss after inoculation. Plasma antibody titers against F. tularensis were higher in rabbits that were vaccinated by either oral or aerosol routes compared to scarification. Thirty days after vaccination, all rabbits were challenged with aerosolized SCHU S4. LVS given by scarification extended time to death compared to mock-vaccinated controls. One orally vaccinated rabbit did survive aerosol challenge, however, only aerosol vaccination extended time to death significantly compared to scarification. These results further demonstrate the utility of the rabbit model of pneumonic tularemia in replicating what has been reported in humans and macaques as well as demonstrating the utility of vaccination by oral and respiratory routes against an aerosol tularemia challenge. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Radiation protection program for early detection of breast cancer in a mammography facility

    Science.gov (United States)

    Villagomez Casimiro, Mariana; Ruiz Trejo, Cesar; Espejo Fonseca, Ruby

    2014-11-01

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1-4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (radiation protection program in this work is applied.

  19. Choosing the right respirator

    International Nuclear Information System (INIS)

    Bidwell, J.

    1997-01-01

    Selecting respirators to help protect workers from airborne contaminants can be a confusing process. The consequences of selecting the incorrect respirator can be intimidating, and worker safety and health may be dramatically and irreparably affected if an inappropriate respirator is chosen. When used in the workplace, a formal respiratory protection program must be established covering the basic requirements outlined in the OSHA Respiratory Protection Standard (29 CFR 1910.134). Education and training must be properly emphasized and conducted periodically. Maintenance, cleaning, and storage programs must be established and routinely followed for reusable respirators. The process of establishing a respiratory protection program can be broken down into four basic steps: Identify respiratory hazards and concentrations; understand the contaminants effects on workers' health; select appropriate respiratory protection; and train in proper respirator use and maintenance. These four steps are the foundation for establishing a basic respirator protection program. Be sure to consult state and federal OSHA requirements to ensure that the program complies. Leading industrial respirator manufacturers should be able to assist with on-site training and education in this four-step process, in addition to helping employers train their workers and conduct respirator fit testing

  20. The Zero Hunger and Brazil without Extreme Poverty programs: a step forward in Brazilian social protection policy.

    Science.gov (United States)

    Paes-Sousa, Romulo; Vaitsman, Jeni

    2014-11-01

    Brazilian social protection programs have had consistent effects in reducing poverty and inequality among their respective target-groups: children, adolescents and pregnant and breastfeeding women. In 2011, the Brazil without Extreme Poverty program was launched as a strategy to eradicate extreme poverty by 2014. It makes the promotion of rights the core concept of the official political narrative. This study seeks to provide a systematic description of the Brazil without Extreme Poverty program and its initial results. A review of official documents and academic studies on the social protection programs was conducted. The Brazil without Extreme Poverty program represents an incremental approach to the social protection policies enacted by the previous administration. It advocates a multidimensional and focused approach, funded primarily by the federal government. The strategy subscribes to the international trend of associating social protection with employment and income generation policies.

  1. Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis.

    Science.gov (United States)

    Neto, Ary Serpa; Simonis, Fabienne D; Barbas, Carmen S V; Biehl, Michelle; Determann, Rogier M; Elmer, Jonathan; Friedman, Gilberto; Gajic, Ognjen; Goldstein, Joshua N; Linko, Rita; Pinheiro de Oliveira, Roselaine; Sundar, Sugantha; Talmor, Daniel; Wolthuis, Esther K; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2015-10-01

    Protective mechanical ventilation with low tidal volumes is standard of care for patients with acute respiratory distress syndrome. The aim of this individual patient data analysis was to determine the association between tidal volume and the occurrence of pulmonary complications in ICU patients without acute respiratory distress syndrome and the association between occurrence of pulmonary complications and outcome in these patients. Individual patient data analysis. ICU patients not fulfilling the consensus criteria for acute respiratory distress syndrome at the onset of ventilation. Mechanical ventilation with low tidal volume. The primary endpoint was development of a composite of acute respiratory distress syndrome and pneumonia during hospital stay. Based on the tertiles of tidal volume size in the first 2 days of ventilation, patients were assigned to a "low tidal volume group" (tidal volumes ≤ 7 mL/kg predicted body weight), an "intermediate tidal volume group" (> 7 and volume group" (≥ 10 mL/kg predicted body weight). Seven investigations (2,184 patients) were included. Acute respiratory distress syndrome or pneumonia occurred in 23% of patients in the low tidal volume group, in 28% of patients in the intermediate tidal volume group, and in 31% of the patients in the high tidal volume group (adjusted odds ratio [low vs high tidal volume group], 0.72; 95% CI, 0.52-0.98; p = 0.042). Occurrence of pulmonary complications was associated with a lower number of ICU-free and hospital-free days and alive at day 28 (10.0 ± 10.9 vs 13.8 ± 11.6 d; p volumes is associated with a lower risk of development of pulmonary complications in patients without acute respiratory distress syndrome.

  2. Bovine respiratory syncytial virus (BRSV) pneumonia in beef calf herds despite vaccination

    DEFF Research Database (Denmark)

    Larsen, Lars Erik; Tegtmeier, C.; Pedersen, E.

    2001-01-01

    to the outbreak. The clinical signs comprised nasal discharge, pyrexia, cough and increased respiratory rates. A total of 28 calves died in the 2 herds. The laboratory investigations revealed that BRSV was involved and probably initiated both outbreaks. Furthermore, the serological results suggested...... beef herds failed to protect the calves against severe or even fatal BRSV mediated respiratory disease 2 months later.......The present report describes the clinical, pathological, serological and virological findings in calves from 2 larger Danish beef herds experiencing outbreaks of pneumonia. The calves had been vaccinated with an inactivated bovine respiratory syncytial virus (BRSV) vaccine 2 months prior...

  3. Impact of nasopharyngeal microbiota on the development of respiratory tract diseases.

    Science.gov (United States)

    Esposito, S; Principi, N

    2018-01-01

    Knowledge of whether and how respiratory microbiota composition can prime the immune system and provide colonisation resistance, limiting consecutive pathobiont overgrowth and infections, is essential to improving the prevention and therapy of respiratory disorders. Modulation of dysbiotic ecosystems or reconstitution of missing microbes might be a possible measure to reduce respiratory diseases. The aim of this review is to analyse the role of nasopharyngeal microbiota in the development of respiratory tract disease in paediatric-age subjects. PubMed was used to search for all studies published over the last 15 years using the following key words: "microbiota" or "microbioma" and "nasopharyngeal" or "respiratory" or "nasal" and "children" or "paediatric" or "infant". Analysis of the literature showed that respiratory microbiota can regulate health and disease development in the respiratory tract. Like the gut microbiota, the respiratory microbiota is established at birth, and early respiratory microbiota composition determines bacterial succession patterns and respiratory health in children. Protective and dangerous bacteria have been identified, and this can be considered the base for developing new approaches to diseases that respond poorly to traditional interventions. Reconstitution of missing microbes can be achieved by the administration of pre- and probiotics. Modulation of respiratory microbiota by favouring colonisation of the upper respiratory tract by beneficial commensals can interfere with the proliferation and activity of resident pathobionts and is a possible new measure to reduce the risk of disease. However, further studies are needed because a deeper understanding of these and related issues can be transferred to clinical practice.

  4. Respiratory and protective equipment at a large nuclear facility

    International Nuclear Information System (INIS)

    Zippler, D.B.

    1975-12-01

    A variety of personal protective equipment is used in a large nuclear facility to protect employees against both nuclear and ordinary industrial materials. Equipment requirements are based on risk evaluation and may range from a minimum of shoe covers to whole body protection by air-supplied plastic suits. Types of equipment are listed and one-year costs are given. Criteria for evaluating and compartmentalizing risks are discussed. Air-supplied suits and hoods are discussed in detail

  5. The radiation protection research within the fourth Framework Program of the European Union (1994-1998)

    International Nuclear Information System (INIS)

    Siunaeve, J.; Mingot, F.; Arranz, L.; Cancio, D.

    1995-01-01

    The next research program on Radiation Protection within the Fourth Framework Program of the European Union has been approved by the Council last December (O.I.N L 361, 12/31/94). The program includes important changes in its structure as well as in the way for implementation in Europe. The most important change is that the main activities concerning Nuclear Safety, Waste Management and Radiation Protection have been included in a single program called Nuclear Fission Safety. The program also includes specific work with CIS countries for the management of Chernobyl consequences as well as other significative contaminations in other areas of the former Soviet Union. (Author)

  6. GPK helmets protecting from gas and dusts

    Energy Technology Data Exchange (ETDEWEB)

    Il' inskii, Eh.G.; Kogan, Yu.A.; Mazanenko, V.P.

    1983-08-01

    The GPK protective helmet with an integrated respirator system protecting a miner's respiratory system and eyes from gases and dusts is described. The system uses compressed air from the mine compressed air system. Air is supplied to the respirator by an elastic rubber pipe to 30 m long. The air cools the miner's head under the helmet and passes between a protective shield and the miner's face protecting eyes and the respiratory system. Air supply ranges from 100 to 150 l/min. The air supplied to the respirator is cleaned by a filter. The GPK system weighs 1.2 kg. The system has been tested under laboratory conditions and in two coal mines under operational conditions at longwall faces and during mine drivage. Tests showed that the GPK guarantees efficient cooling and protection from dust. Design of the GPK helmet with a respirator is shown in two schemes. Technical specifications of the system are given.

  7. Fourth conference on radiation protection and dosimetry: Proceedings, program, and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Casson, W.H.; Thein, C.M.; Bogard, J.S. [eds.

    1994-10-01

    This Conference is the fourth in a series of conferences organized by staff members of Oak Ridge National Laboratory in an effort to improve communication in the field of radiation protection and dosimetry. Scientists, regulators, managers, professionals, technologists, and vendors from the United States and countries around the world have taken advantage of this opportunity to meet with their contemporaries and peers in order to exchange information and ideas. The program includes over 100 papers in 9 sessions, plus an additional session for works in progress. Papers are presented in external dosimetry, internal dosimetry, radiation protection programs and assessments, developments in instrumentation and materials, environmental and medical applications, and on topics related to standards, accreditation, and calibration. Individual papers are indexed separately on EDB.

  8. Incidence Proportion of Acute Cor Pulmonale in Patients with Acute Respiratory Distress Syndrome Subjected to Lung Protective Ventilation: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Das, Saurabh Kumar; Choupoo, Nang Sujali; Saikia, Priyam; Lahkar, Amitabh

    2017-06-01

    Reported incidence of acute cor pulmonale (ACP) in patients with acute respiratory distress syndrome (ARDS) varies from 10% to 84%, despite being subjected to lung protective ventilation according to the current guidelines. The objective of this review is to find pooled cumulative incidence of ACP in patients with ARDS undergoing lung protective ventilation. We searched MEDLINE, EMBASE, Cochrane Library, KoreaMed, LILACS, and WHO Clinical Trial Registry. Cross-sectional or cohort studies were included if they reported or provided data that could be used to calculate the incidence proportion of ACP. Inverse variance heterogeneity (IVhet) and random effect model were used for the main outcome and measures. We included 16 studies encompassing 1661 patients. The cumulative incidence of ACP using IVhet analysis was 23% (95% confidence interval [CI] = 18%-28%) over 3 days of lung protective ventilation. Random effect analysis of 7 studies (1250 patients) revealed pooled odd ratio of mortality of 1.16 (95% CI = 0.80-1.67, P = 0.44) due to ACP. Patients with ARDS have a 23% risk of developing ACP with lung protective ventilation. Findings of this review indicate the need of updating existing guidelines for ventilating ARDS patients to incorporate right ventricle protective strategy.

  9. Developing a model lifeline protection program for DOE facilities

    International Nuclear Information System (INIS)

    Lowing, A.N.

    1996-01-01

    A National Lifeline Standard Development Program is currently being conducted by FEMA and NIST. The Department of Energy is following these developments and supplementing them to meet Life-Safety and mission requirements for all DOE facilities as part of the Natural Phenomena Hazards Mitigation Plan. The task will be overseen by a DOE management team with technical guidance provided by a Steering Group of management and operating contractor representatives. The DOE will participate in the federal program by conducting a workshop on lifeline protection issues, developing an overall plan, organizing a Steering Group, and conducting a pilot study at a DOE facility

  10. A new paradigm in respiratory hygiene: modulating respiratory secretions to contain cough bioaerosol without affecting mucus clearance

    Directory of Open Access Journals (Sweden)

    Bonilla Gloria

    2007-08-01

    Full Text Available Abstract Background Several strategies and devices have been designed to protect health care providers from acquiring transmissible respiratory diseases while providing care. In modulating the physical characteristics of the respiratory secretions to minimize the aerosolization that facilitates transmission of airborne diseases, a fundamental premise is that the prototype drugs have no adverse effect on the first line of respiratory defense, clearance of mucus by ciliary action. Methods To assess and demonstrate the primary mechanism of our mucomodulators (XLs, we have built our evidence moving from basic laboratory studies to an ex-vivo model and then to an in-vivo large animal model. We exposed anesthetized dogs without hypersecretion to different dose concentrations of aerosolized XL "B", XL "D" and XL "S". We assessed: cardio-respiratory pattern, tracheal mucus clearance, airway patency, and mucus viscoelastic changes. Results Exposure of frog palate mucus to XLs did not affect the clearance of mucus by ciliary action. Dogs maintained normal cardio-respiratory pattern with XL administration. Tracheal mucociliary clearance in anesthetized dogs indicated a sustained 40% mean increase. Tracheal mucus showed increased filance, and there was no mucus retention in the airways. Conclusion The ex-vivo frog palate and the in-vivo mammalian models used in this study, appear to be appropriate and complement each other to better assess the effects that our mucomodulators exert on the mucociliary clearance defence mechanism. The physiological function of the mucociliary apparatus was not negatively affected in any of the two epithelial models. Airway mucus crosslinked by mucomodulators is better cleared from an intact airway and normally functioning respiratory system, either due to enhanced interaction with cilia or airflow-dependent mechanisms. Data obtained in this study allow us to assure that we have complied with the fundamental requirement

  11. ROLE OF MONOCYTES AND EOSINOPHILS IN RESPIRATORY SYNCTIAL VIRUS (RSV) INFECTION

    Science.gov (United States)

    Role of Monocytes and Eosinophils in Respiratory Syncytial Virus (RSV) InfectionJoleen M. Soukup and Susanne Becker US Environmental Protection Agency, National Health and Environmental Effects Research Laboratory, Research Triangle Park, NC 27711;...

  12. Social marketing campaign promoting the use of respiratory protection devices among farmers.

    Science.gov (United States)

    Pounds, Lea; Duysen, Ellen; Romberger, Debra; Cramer, Mary E; Wendl, Mary; Rautiainen, Risto

    2014-01-01

    This article describes the formal use of marketing concepts in a systematic approach to influence farmers to voluntarily increase respiratory protective device (RPD) use. The planning process for the project incorporated six key decision or action points, each informed by formative research or health behavior theory. The planning process included developing behavior change strategies based on a 4P model (product, price, place, and promotion). The resulting campaign elements included print and e-mail messages that leveraged motivators related to family and health in order to increase farmers' knowledge about the risks of exposure to dusty environments, four instructional videos related to the primary barriers identified in using RPDs, and a brightly colored storage bag to address barriers to using RPDs related to mask storage. Campaign implementation included a series of e-mails using a bulk e-mail subscription service, use of social media in the form of posting instructional videos on a YouTube channel, and in-person interactions with members of the target audience at farm shows throughout the Central States Center for Agricultural Safety and Health seven-state region. Evaluation of the e-mail campaigns indicated increased knowledge about RPD use and intent to use RPDs in dusty conditions. YouTube analytic data indicated continuing exposure of the instructional videos beyond the life of the campaign. The project demonstrates the efficacy of a planning process that incorporates formative research and clear decision points throughout. This process could be used to plan health behavior change interventions to address other agriculture-related health and safety issues.

  13. Effect of tangeretin on ovalbumin-provoked allergic respiratory ...

    African Journals Online (AJOL)

    Conclusion: These results demonstrate that tangeritin exerts protective effects against OVA-induced allergic respiratory asthma in Swiss albino mice, and that the drug can potentially be .... (0.1 mg/kg) was injected to suppress inhalation, and the mice were allowed ventilation from oxygen-filled air at 120 beats/min, with beat ...

  14. Variable tidal volumes improve lung protective ventilation strategies in experimental lung injury.

    Science.gov (United States)

    Spieth, Peter M; Carvalho, Alysson R; Pelosi, Paolo; Hoehn, Catharina; Meissner, Christoph; Kasper, Michael; Hübler, Matthias; von Neindorff, Matthias; Dassow, Constanze; Barrenschee, Martina; Uhlig, Stefan; Koch, Thea; de Abreu, Marcelo Gama

    2009-04-15

    Noisy ventilation with variable Vt may improve respiratory function in acute lung injury. To determine the impact of noisy ventilation on respiratory function and its biological effects on lung parenchyma compared with conventional protective mechanical ventilation strategies. In a porcine surfactant depletion model of lung injury, we randomly combined noisy ventilation with the ARDS Network protocol or the open lung approach (n = 9 per group). Respiratory mechanics, gas exchange, and distribution of pulmonary blood flow were measured at intervals over a 6-hour period. Postmortem, lung tissue was analyzed to determine histological damage, mechanical stress, and inflammation. We found that, at comparable minute ventilation, noisy ventilation (1) improved arterial oxygenation and reduced mean inspiratory peak airway pressure and elastance of the respiratory system compared with the ARDS Network protocol and the open lung approach, (2) redistributed pulmonary blood flow to caudal zones compared with the ARDS Network protocol and to peripheral ones compared with the open lung approach, (3) reduced histological damage in comparison to both protective ventilation strategies, and (4) did not increase lung inflammation or mechanical stress. Noisy ventilation with variable Vt and fixed respiratory frequency improves respiratory function and reduces histological damage compared with standard protective ventilation strategies.

  15. 25 CFR 63.30 - What is the purpose of the Indian child protection and family violence prevention program?

    Science.gov (United States)

    2010-04-01

    ... family violence prevention program? 63.30 Section 63.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Indian Child Protection and Family Violence Prevention Program § 63.30 What is the purpose of the Indian child protection...

  16. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain : Impact on respiratory muscle function, activity, mood and exercise capacity

    OpenAIRE

    會田, 信子; 渋谷, 優子; 吉野, 克樹; Komoda, Masaji; 井上, 智子

    2002-01-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) g...

  17. Respiratory acidosis

    Science.gov (United States)

    Ventilatory failure; Respiratory failure; Acidosis - respiratory ... Causes of respiratory acidosis include: Diseases of the airways (such as asthma and COPD ) Diseases of the lung tissue (such as ...

  18. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    International Nuclear Information System (INIS)

    2005-01-01

    The DOE established the Groundwater Monitoring Program (GMP) (WP 02-1) to monitor groundwater resources at WIPP. In the past, the GMP was conducted to establish background data of existing conditions of groundwater quality and quantity in the WIPP vicinity, and to develop and maintain a water quality database as required by regulation. Today the GMP is conducted consistent with 204.1.500 NMAC (New Mexico Administrative Code), 'Adoption of 40 CFR [Code of Federal Regulations] Part 264,'specifically 40 CFR 264.90 through 264.101. These sections of 20.4.1 NMAC provide guidance for detection monitoring of groundwater that is, or could be, affected by waste management activities at WIPP. Detection monitoring at WIPP is designed to detect contaminants in the groundwater long before the general population is exposed. Early detection will allow cleanup efforts to be accomplished before any exposure to the general population can occur. Title 40 CFR Part 264, Subpart F, stipulates minimum requirements of Resource Conservation and Recovery Act of 1976 (42 United States Code [U.S.C.] 6901 et seq.) (RCRA) groundwater monitoring programs including the number and location of monitoring wells; sampling and reporting schedules; analytical methods and accuracy requirements; monitoring parameters; and statistical treatment of monitoring data. This document outlines how WIPP intends to protect and preserve groundwater within the WIPP Land Withdrawal Area (WLWA). Groundwater protection is just one aspect of the WIPP environmental protection effort. An overview of the entire environmental protection effort can be found in DOE/WIPP 99-2194, Waste Isolation Pilot Plant Environmental Monitoring Plan. The WIPP GMP is designed to statistically determine if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will then be determined and the appropriate corrective action(s) initiated.

  19. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Washington Regulatory and Environmental Services

    2005-07-01

    The DOE established the Groundwater Monitoring Program (GMP) (WP 02-1) to monitor groundwater resources at WIPP. In the past, the GMP was conducted to establish background data of existing conditions of groundwater quality and quantity in the WIPP vicinity, and to develop and maintain a water quality database as required by regulation. Today the GMP is conducted consistent with 204.1.500 NMAC (New MexicoAdministrative Code), "Adoption of 40 CFR [Code of Federal Regulations] Part 264,"specifically 40 CFR §264.90 through §264.101. These sections of 20.4.1 NMAC provide guidance for detection monitoring of groundwater that is, or could be, affected by waste management activities at WIPP. Detection monitoring at WIPP is designed to detect contaminants in the groundwater long before the general population is exposed. Early detection will allow cleanup efforts to be accomplished before any exposure to the general population can occur. Title 40 CFR Part 264, Subpart F, stipulates minimum requirements of Resource Conservation and Recovery Act of 1976 (42 United States Code [U.S.C.] §6901 et seq.) (RCRA) groundwater monitoring programs including the number and location of monitoring wells; sampling and reporting schedules; analytical methods and accuracy requirements; monitoring parameters; and statistical treatment of monitoring data. This document outlines how WIPP intends to protect and preserve groundwater within the WIPP Land Withdrawal Area (WLWA). Groundwater protection is just one aspect of the WIPP environmental protection effort. An overview of the entire environmental protection effort can be found in DOE/WIPP 99-2194, Waste Isolation Pilot Plant Environmental Monitoring Plan. The WIPP GMP is designed to statistically determine if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will then be determined and the appropriate corrective action(s) initiated.

  20. Assessment of respiratory symptoms and lung function among textile ...

    African Journals Online (AJOL)

    The smokers among the exposed and unexposed workers had significantly lower lung function values than nonsmokers. Conclusion: Respiratory symptoms were more prevalent among workers in most dusty sections of the factory. Use of protective mask should be enforced. Workers in the spinning and weaving sections of ...

  1. Hypercapnic respiratory acidosis: a protective or harmful strategy for critically ill newborn foals?

    Science.gov (United States)

    Vengust, Modest

    2012-10-01

    This paper reviews both the beneficial and adverse effects of permissive hypercapnic respiratory acidosis in critically ill newborn foals. It has been shown that partial carbon dioxide pressure (PCO2) above the traditional safe range (hypercapnia), has beneficial effects on the physiology of the respiratory, cardiovascular, and nervous system in neonates. In human neonatal critical care medicine permissive hypercapnic acidosis is generally well-tolerated by patients and is more beneficial to their wellbeing than normal carbon dioxide (CO2) pressure or normocapnia. Even though adverse effects of hypercapnia have been reported, especially in patients with central nervous system pathology and/or chronic infection, critical care clinicians often artificially increase PCO2 to take advantage of its positive effects on compromised neonate tissues. This is referred to as therapeutic hypercapnia. Hypercapnic respiratory acidosis is common in critically ill newborn foals and has traditionally been considered as not beneficial. A search of online scientific databases was conducted to survey the literature on the effects of hypercapnia in neonates, with emphasis on newborn foals. The dynamic status of safety levels of PCO2 and data on the effectiveness of different carbon dioxide levels are not available for newborn foals and should be scientifically determined. Presently, permissive hypercapnia should be implemented or tolerated cautiously in compromised newborn foals and its use should be based on relevant data from adult horses and other species.

  2. Hazardous materials management and control program at Oak Ridge National Laboratory - environmental protection

    International Nuclear Information System (INIS)

    Eisenhower, B.M.; Oakes, T.W.

    1982-01-01

    In the Federal Register of May 19, 1980, the US Environmental Protection Agency promulgated final hazardous waste regulations according to the Resource Conservation and Recovery Act (RCRA) of 1976. The major substantive portions of these regulations went into effect on November 19, 1980, and established a federal program to provide comprehensive regulation of hazardous waste from its generation to its disposal. In an effort to comply with these regulations, a Hazardous Materials Management and Control Program was established at Oak Ridge National Laboratory. The program is administered by two Hazardous Materials Coordinators, who together with various support groups, ensure that all hazardous materials and wastes are handled in such a manner that all personnel, the general public, and the environment are adequately protected

  3. Hand hygiene to reduce community transmission of influenza and acute respiratory tract infection: a systematic review.

    OpenAIRE

    Warren-Gash, C; Fragaszy, E; Hayward, AC

    2012-01-01

    : Please cite this paper as: Warren-Gash et al. (2012) Hand hygiene to reduce community transmission of influenza and acute respiratory tract infection: a systematic review. Influenza and Other Respiratory Viruses DOI: 10.1111/irv.12015. Hand hygiene may be associated with modest protection against some acute respiratory tract infections, but its specific role in influenza transmission in different settings is unclear. We aimed to review evidence that improving hand hygiene reduces primary an...

  4. Environmental monitoring and radiation protection programs of Novi Han radioactive waste repository

    International Nuclear Information System (INIS)

    Christoskova, M.; Kostova, M.; Sheherov, L.; Bekiarov, P.; Iovtchev, M.

    2000-01-01

    The system for monitoring and control as an important part of the safety management of the Novi Han Radioactive Waste Repository contains two independent programs: environmental monitoring of the site (controlled area), the restricted access area and the surveillance area (supervised area) of the repository and radiation protection program including personal dosimetric control and indoor dosimetric control of workplaces in the buildings of the repository. The main activities related to the programs implementation are presented

  5. Adult venovenous extracorporeal membrane oxygenation for severe respiratory failure: Current status and future perspectives.

    Science.gov (United States)

    Sen, Ayan; Callisen, Hannelisa E; Alwardt, Cory M; Larson, Joel S; Lowell, Amelia A; Libricz, Stacy L; Tarwade, Pritee; Patel, Bhavesh M; Ramakrishna, Harish

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) for severe acute respiratory failure was proposed more than 40 years ago. Despite the publication of the ARDSNet study and adoption of lung protective ventilation, the mortality for acute respiratory failure due to acute respiratory distress syndrome has continued to remain high. This technology has evolved over the past couple of decades and has been noted to be safe and successful, especially during the worldwide H1N1 influenza pandemic with good survival rates. The primary indications for ECMO in acute respiratory failure include severe refractory hypoxemic and hypercarbic respiratory failure in spite of maximum lung protective ventilatory support. Various triage criteria have been described and published. Contraindications exist when application of ECMO may be futile or technically impossible. Knowledge and appreciation of the circuit, cannulae, and the physiology of gas exchange with ECMO are necessary to ensure lung rest, efficiency of oxygenation, and ventilation as well as troubleshooting problems. Anticoagulation is a major concern with ECMO, and the evidence is evolving with respect to diagnostic testing and use of anticoagulants. Clinical management of the patient includes comprehensive critical care addressing sedation and neurologic issues, ensuring lung recruitment, diuresis, early enteral nutrition, treatment and surveillance of infections, and multisystem organ support. Newer technology that delinks oxygenation and ventilation by extracorporeal carbon dioxide removal may lead to ultra-lung protective ventilation, avoidance of endotracheal intubation in some situations, and ambulatory therapies as a bridge to lung transplantation. Risks, complications, and long-term outcomes and resources need to be considered and weighed in before widespread application. Ethical challenges are a reality and a multidisciplinary approach that should be adopted for every case in consideration.

  6. Project Radiation Protection East. Swedish cooperation program for radiation protection in Eastern and Central Europe. Status Report, March 1996

    International Nuclear Information System (INIS)

    Snihs, J.O.; Johansson, Mai; Grapengiesser, S.; Bennerstedt, T.

    1996-04-01

    Until now the Swedish program for radiation protection work in central and Eastern europe has been granted 55 MSEK by the Swedish government. The projects are assessed, planned and performed in close cooperation with partner organizations in the East. Since 1994, radiation protection cooperation concerning the former Soviet Navy training reactors in Paldiski, Estonia, is included in Radiation Protection East. The government has granted 8 MSEK for this purpose. This report presents a summary over some 150 projects, their status, allocated funds and their distribution over countries and project areas. The presentation is updated up to March 1996. 7 figs

  7. The effect of personal experience on choice-based preferences for wildfire protection programs

    Science.gov (United States)

    Tom Holmes; Armando Gonzalez-Caban; John Loomis; Jose Sanchez

    2013-01-01

    In this paper, we investigate homeowner preferences and willingness to pay for wildfire protection programs using a choice experiment with three attributes: risk, loss and cost. Preference heterogeneity among survey respondents was examined using three econometric models and risk preferences were evaluated by comparing willingness to pay for wildfire protection...

  8. Auditory and Respiratory Health Disorders Among Workers in an ...

    African Journals Online (AJOL)

    For early detection of respiratory and auditory disorders, spirometry and audiometry should be included in the periodic medical examination. Accurate health records of workers, so, those at risk can be monitored, and/or pre-placed. Using personal protective equipments especially masks and ear muffles as well as prohibit ...

  9. A novel anti-influenza copper oxide containing respiratory face mask.

    Science.gov (United States)

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.

  10. Acute lung injury and the acute respiratory distress syndrome in the injured patient

    Directory of Open Access Journals (Sweden)

    Bakowitz Magdalena

    2012-08-01

    Full Text Available Abstract Acute lung injury and acute respiratory distress syndrome are clinical entities of multi-factorial origin frequently seen in traumatically injured patients requiring intensive care. We performed an unsystematic search using PubMed and the Cochrane Database of Systematic Reviews up to January 2012. The purpose of this article is to review recent evidence for the pathophysiology and the management of acute lung injury/acute respiratory distress syndrome in the critically injured patient. Lung protective ventilation remains the most beneficial therapy. Future trials should compare intervention groups to controls receiving lung protective ventilation, and focus on relevant outcome measures such as duration of mechanical ventilation, length of intensive care unit stay, and mortality.

  11. 25 CFR 63.34 - How are Indian child protection and family violence prevention program funds distributed?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false How are Indian child protection and family violence... INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Indian Child Protection and Family Violence Prevention Program § 63.34 How are Indian child protection and family violence...

  12. Implementation of the G8GP program on physical protection - experiences and results

    International Nuclear Information System (INIS)

    Hagemann, A.

    2006-01-01

    At the Kananaskis Summit in June 2002, G8 Leaders launched the Global Partnership against the Spread of Weapons and Materials of Mass Destruction committing to support projects to issues of non-proliferation, disarmament, counter terrorism and nuclear safety in Russia. Since then progress has been made in implementing projects. The German Federal Foreign Office contracted GRS to implement a program for improving the physical protection of nuclear or highly radioactive materials of relevance at facilities in the Russian Federation. This paper reports about this G8GP Program on physical protection, its implementation, gained experiences, current achievements and results. (author)

  13. Respiratory risks in broiler production workers

    Directory of Open Access Journals (Sweden)

    M do CB de Alencar

    2004-03-01

    Full Text Available There are many situations that involve health risks to the Brazilian rural worker, and animal production is just one of them. Inhalation of organic dust, which has many microorganisms, leads in general to respiratory allergic reactions in some individuals, "asthma-like syndrome", and mucous membrane inflammation syndrome, that is a complex of nasal, eye, and throat complaints. Furthermore, workers might have farmer's hypersensitivity pneumonia, that is a respiratory health risk along the years. The objective of this study was to evaluate the potential pulmonary health risks in poultry production workers in the region of Curitiba, PR, Brazil. Interviews using a pre-elaborated questionnaire with 40 questions were made with 37 broiler production workers, which were submitted to a pulmonary function test. Results of restrictive function with lower FEV1 (the maximum respiratory potential, the forced expiratory volume in the first second of exhalation and FVC (forced vital capacity represented 24.32% of the total of workers, and severe obstruction represented 2.70%. Other symptoms were found in 67.57% of the workers as well. The results showed that those who work more than 4 years and within more than one poultry house, exceeding 5 hours per day of work, presented higher pulmonary health risks. It is concluded that the activities within broiler houses may induce allergic respiratory reaction in workers. The use of IPE (individual protection equipment besides special attention to the air quality inside the housing may be advised in a preventive way.

  14. Emerging indications for extracorporeal membrane oxygenation in adults with respiratory failure.

    Science.gov (United States)

    Abrams, Darryl; Brodie, Daniel

    2013-08-01

    Recent advances in technology have spurred the increasing use of extracorporeal membrane oxygenation (ECMO) in patients with severe hypoxemic respiratory failure. However, this accounts for only a small percentage of patients with respiratory failure. We envision the application of ECMO in many other forms of respiratory failure in the coming years. Patients with less severe forms of acute respiratory distress syndrome, for instance, may benefit from enhanced lung-protective ventilation with the very low tidal volumes made possible by direct carbon dioxide removal from the blood. For those in whom hypercapnia predominates, extracorporeal support will allow for the elimination of invasive mechanical ventilation in some cases. The potential benefits of ECMO may be further enhanced by improved techniques, which facilitate active mobilization. Although ECMO for these and other expanded applications is under active investigation, it has yet to be proven beneficial in these settings in rigorous controlled trials. Ultimately, with upcoming and future technological advances, there is the promise of true destination therapy, which could lead to a major paradigm shift in the management of respiratory failure.

  15. Respiratory alkalosis

    Science.gov (United States)

    Alkalosis - respiratory ... leads to shortness of breath can also cause respiratory alkalosis (such as pulmonary embolism and asthma). ... Treatment is aimed at the condition that causes respiratory alkalosis. Breathing into a paper bag -- or using ...

  16. Comparisons of calculated respiratory tract deposition of particles based on the NCRP/ITRI model and the new ICRP66 model

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Hsu-Chi; Phalen, R.F. [Univ. of California, Irvine, CA (United States); Chang, I. [Lovelace Inst., Albuquerque, NM (United States)] [and others

    1995-12-01

    The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Although this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny ({approximately} 1 nm) to particles larger than 100 {mu}m. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar.

  17. Comparisons of calculated respiratory tract deposition of particles based on the NCRP/ITRI model and the new ICRP66 model

    International Nuclear Information System (INIS)

    Yeh, Hsu-Chi; Phalen, R.F.; Chang, I.

    1995-01-01

    The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Although this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny (∼ 1 nm) to particles larger than 100 μm. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar

  18. Working experiences of nurses during the Middle East respiratory syndrome outbreak.

    Science.gov (United States)

    Kang, Hee Sun; Son, Ye Dong; Chae, Sun-Mi; Corte, Colleen

    2018-05-30

    To explore working experiences of nurses during Middle East respiratory syndrome outbreak. Since the first case of Middle East respiratory syndrome was reported on May 20, 2015 in South Korea, 186 people, including health care workers, were infected, and 36 died. A qualitative descriptive study. Seven focus groups and 3 individual in-depth interviews were conducted from August to December 2015. Content analysis was used. The following 4 major themes emerged: "experiencing burnout owing to the heavy workload," "relying on personal protective equipment for safety," "being busy with catching up with the new guidelines related to Middle East respiratory syndrome," and "caring for suspected or infected patients with caution." Participants experienced burnout because of the high volume of work and expressed safety concerns about being infected. Unclear and frequently changing guidelines were 1 of the common causes of confusion. Participants expressed that they need to be supported while caring for suspected or infected patients. This study showed that creating a supportive and safe work environment is essential by ensuring adequate nurse staffing, supplying best-quality personal protective equipment, and improving communication to provide the quality of care during infection outbreak. © 2018 John Wiley & Sons Australia, Ltd.

  19. Can an hour or two of sun protection education keep the sunburn away? Evaluation of the Environmental Protection Agency's Sunwise School Program

    Directory of Open Access Journals (Sweden)

    Kenausis Kristin

    2003-11-01

    Full Text Available Abstract Background Melanoma incidence is rising at a rate faster than any other preventable cancer in the United States. Childhood exposure to ultraviolet (UV light increases risk for skin cancer as an adult, thus starting positive sun protection habits early may be key to reducing the incidence of this disease. Methods The Environmental Protection Agency's SunWise School Program, a national environmental and health education program for sun safety of children in primary and secondary schools (grades K-8, was evaluated with surveys administered to participating students and faculty. Results Pretests (n = 5,625 and posttests (n = 5,028 were completed by students in 102 schools in 42 states. Significant improvement was noted for the three knowledge variables. Intentions to play in the shade increased from 68% to 75%(p Conclusions Brief, standardized sun protection education can be efficiently interwoven into existing school curricula, and result in improvements in knowledge and positive intentions for sun protection.

  20. 77 FR 32397 - Servicemembers' Group Life Insurance Traumatic Injury Protection Program-Genitourinary Losses

    Science.gov (United States)

    2012-06-01

    ... payable. The additional GU losses are being added to the TSGLI program in response to the increase in the... Traumatic Injury Protection Program--Genitourinary Losses AGENCY: Department of Veterans Affairs. ACTION... adding certain genitourinary (GU) system losses to the TSGLI Schedule of Losses and defining terms...

  1. 77 FR 37060 - Critical Infrastructure and Key Resources (CIKR) Asset Protection Technical Assistance Program...

    Science.gov (United States)

    2012-06-20

    .../IP/IICD, 245 Murray Lane SW., Mailstop 0602, Arlington, VA 20598-0602. Email requests should go to...), National Protection and Programs Directorate (NPPD), Office of Infrastructure Protection (IP... the following methods: Federal eRulemaking Portal: http://www.regulations.gov . Email: Include the...

  2. Vaccination against acute respiratory virus infections and measles in man.

    NARCIS (Netherlands)

    A.D.M.E. Osterhaus (Albert); P. de Vries (Petra)

    1992-01-01

    textabstractSeveral viruses may cause more or less severe acute respiratory infections in man, some of which are followed by systemic infection. Only for influenza and measles are licensed vaccines available at present. The protection induced by influenza vaccines, which are based on inactivated

  3. Fifty Years of Research in ARDS. Respiratory Mechanics in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Henderson, William R; Chen, Lu; Amato, Marcelo B P; Brochard, Laurent J

    2017-10-01

    Acute respiratory distress syndrome is a multifactorial lung injury that continues to be associated with high levels of morbidity and mortality. Mechanical ventilation, although lifesaving, is associated with new iatrogenic injury. Current best practice involves the use of small Vt, low plateau and driving pressures, and high levels of positive end-expiratory pressure. Collectively, these interventions are termed "lung-protective ventilation." Recent investigations suggest that individualized measurements of pulmonary mechanical variables rather than population-based ventilation prescriptions may be used to set the ventilator with the potential to improve outcomes beyond those achieved with standard lung protective ventilation. This review outlines the measurement and application of clinically applicable pulmonary mechanical concepts, such as plateau pressures, driving pressure, transpulmonary pressures, stress index, and measurement of strain. In addition, the concept of the "baby lung" and the utility of dynamic in addition to static measures of pulmonary mechanical variables are discussed.

  4. 25 CFR 63.32 - Under what authority are Indian child protection and family violence prevention program funds...

    Science.gov (United States)

    2010-04-01

    ... family violence prevention program funds awarded? 63.32 Section 63.32 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Indian Child Protection and Family Violence Prevention Program § 63.32 Under what authority are Indian child...

  5. 76 FR 16000 - Voluntary Protection Programs Information; Extension of the Office of Management and Budget's...

    Science.gov (United States)

    2011-03-22

    ... management programs including how the programs successfully address management leadership and employee...] Voluntary Protection Programs Information; Extension of the Office of Management and Budget's (OMB's... concerning its proposal to extend the Office of Management and Budget's (OMB's) approval of the information...

  6. Sevoflurane postconditioning improves myocardial mitochondrial respiratory function and reduces myocardial ischemia-reperfusion injury by up-regulating HIF-1.

    Science.gov (United States)

    Yang, Long; Xie, Peng; Wu, Jianjiang; Yu, Jin; Yu, Tian; Wang, Haiying; Wang, Jiang; Xia, Zhengyuan; Zheng, Hong

    2016-01-01

    Sevoflurane postconditioning (SPostC) can exert myocardial protective effects similar to ischemic preconditioning. However, the exact myocardial protection mechanism by SPostC is unclear. Studies indicate that hypoxia-inducible factor-1 (HIF-1) maintains cellular respiration homeostasis by regulating mitochondrial respiratory chain enzyme activity under hypoxic conditions. This study investigated whether SPostC could regulate the expression of myocardial HIF-1α and to improve mitochondrial respiratory function, thereby relieving myocardial ischemia-reperfusion injury in rats. The myocardial ischemia-reperfusion rat model was established using the Langendorff isolated heart perfusion apparatus. Additionally, postconditioning was performed using sevoflurane alone or in combination with the HIF-1α inhibitor 2-methoxyestradiol (2ME2). The changes in hemodynamic parameters, HIF-1α protein expression levels, mitochondrial respiratory function and enzyme activity, mitochondrial reactive oxygen species (ROS) production rates, and mitochondrial ultrastructure were measured or observed. Compared to the ischemia-reperfusion (I/R) group, HIF-1α expression in the SPostC group was significantly up-regulated. Additionally, cardiac function indicators, mitochondrial state 3 respiratory rate, respiratory control ratio (RCR), cytochrome C oxidase (C c O), NADH oxidase (NADHO), and succinate oxidase (SUCO) activities, mitochondrial ROS production rate, and mitochondrial ultrastructure were significantly better than those in the I/R group. However, these advantages were completely reversed by the HIF-1α specific inhibitor 2ME2 ( P <0.05). The myocardial protective function of SPostC might be associated with the improvement of mitochondrial respiratory function after up-regulation of HIF-1α expression.

  7. Perioperative lung protective ventilation in obese patients

    OpenAIRE

    Fernandez-Bustamante, Ana; Hashimoto, Soshi; Serpa Neto, Ary; Moine, Pierre; Vidal Melo, Marcos F; Repine, John E

    2015-01-01

    The perioperative use and relevance of protective ventilation in surgical patients is being increasingly recognized. Obesity poses particular challenges to adequate mechanical ventilation in addition to surgical constraints, primarily by restricted lung mechanics due to excessive adiposity, frequent respiratory comorbidities (i.e. sleep apnea, asthma), and concerns of postoperative respiratory depression and other pulmonary complications. The number of surgical patients with obesity is increa...

  8. A Respiratory Syncytial Virus Vaccine Vectored by a Stable Chimeric and Replication-Deficient Sendai Virus Protects Mice without Inducing Enhanced Disease.

    Science.gov (United States)

    Wiegand, Marian Alexander; Gori-Savellini, Gianni; Gandolfo, Claudia; Papa, Guido; Kaufmann, Christine; Felder, Eva; Ginori, Alessandro; Disanto, Maria Giulia; Spina, Donatella; Cusi, Maria Grazia

    2017-05-15

    Respiratory syncytial virus (RSV) is a major cause of severe respiratory infections in children and elderly people, and no marketed vaccine exists. In this study, we generated and analyzed a subunit vaccine against RSV based on a novel genome replication-deficient Sendai virus (SeV) vector. We inserted the RSV F protein, known to be a genetically stable antigen, into our vector in a specific way to optimize the vaccine features. By exchanging the ectodomain of the SeV F protein for its counterpart from RSV, we created a chimeric vectored vaccine that contains the RSV F protein as an essential structural component. In this way, the antigen is actively expressed on the surfaces of vaccine particles in its prefusion conformation, and as recently reported for other vectored vaccines, the occurrence of silencing mutations of the transgene in the vaccine genome can be prevented. In addition, its active gene expression contributes to further stimulation of the immune response. In order to understand the best route of immunization, we compared vaccine efficacies after intranasal (i.n.) or intramuscular (i.m.) immunization of BALB/c mice. Via both routes, substantial RSV-specific immune responses were induced, consisting of serum IgG and neutralizing antibodies, as well as cytotoxic T cells. Moreover, i.n. immunization was also able to stimulate specific mucosal IgA in the upper and lower respiratory tract. In virus challenge experiments, animals were protected against RSV infection after both i.n. and i.m. immunization without inducing vaccine-enhanced disease. Above all, the replication-deficient SeV appeared to be safe and well tolerated. IMPORTANCE Respiratory syncytial virus (RSV) is a major cause of respiratory diseases in young children and elderly people worldwide. There is a great demand for a licensed vaccine. Promising existing vaccine approaches based on live-attenuated vaccines or viral vectors have suffered from unforeseen drawbacks related to immunogenicity

  9. Independent auto evaluation of an operative radiological protection program; Autoevaluacion independiente de un programa de proteccion radiologica operativa

    Energy Technology Data Exchange (ETDEWEB)

    Medrano L, M.A.; Rodriguez C, C.C.; Linares R, D.; Zarate M, N.; Zempoalteca B, R. [Gerencia Subsede Sureste Instituto Nacional de Investigaciones Nucleares, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: maam@nuclear.inin.mx

    2006-07-01

    The program of operative radiological protection of a nuclear power plant consists of multiple procedures and associate tasks that have as purpose the radiological protection of the workers of the power station. It is for this reason that the constant evaluation of the one it programs it is an important tool in the identification of their weaknesses (and strengths), so they can be assisted appropriately. In this work the main elements of the program of independent auto evaluation of the program of operative radiological protection of the Laguna Verde Central that has been developed and implemented by the National Institute of Nuclear Research are described. (Author)

  10. Upper Respiratory Tract Diseases in Athletes in Different Sports Disciplines.

    Science.gov (United States)

    Gałązka-Franta, Anna; Jura-Szołtys, Edyta; Smółka, Wojciech; Gawlik, Radosław

    2016-12-01

    Upper respiratory tract diseases in athletes are a very common medical problem. Training conditions in different sports disciplines increase the risk of upper respiratory disease. Epidemiological evidence suggests that heavy acute or chronic exercise is related to an increased incidence of upper respiratory tract infections in athletes. Regular physical exercise at high intensity may lead to transient immunosuppression due to high prevalence of allergic diseases in athletes. Regardless of the cause they can exclude athletes from the training program and significantly impair their performance. In the present work, the most common upper respiratory tract diseases in athletes taking into account the disciplines in which they most often occur were presented. The focus was laid on symptoms, diagnostic methods and pharmacotherapy. Moreover, preventive procedures which can help reduce the occurrence of upper respiratory tract disease in athletes were presented. Management according to anti-doping rules, criteria for return to training and competition as an important issues of athlete's health were discussed.

  11. The Respiratory System. Instructional Materials in Anatomy and Physiology for Pennsylvania Health Occupations Programs.

    Science.gov (United States)

    National Evaluation Systems, Inc., Amherst, MA.

    This instructional modular unit with instructor's guide provides materials on aspects of one of the major systems of the human body--the respiratory system. Its purpose is to introduce the student to the structures and functions of the human respiratory system--and the interrelationships of the two--and to famlliarize the student with some of the…

  12. Adult venovenous extracorporeal membrane oxygenation for severe respiratory failure: Current status and future perspectives

    Directory of Open Access Journals (Sweden)

    Ayan Sen

    2016-01-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO for severe acute respiratory failure was proposed more than 40 years ago. Despite the publication of the ARDSNet study and adoption of lung protective ventilation, the mortality for acute respiratory failure due to acute respiratory distress syndrome has continued to remain high. This technology has evolved over the past couple of decades and has been noted to be safe and successful, especially during the worldwide H1N1 influenza pandemic with good survival rates. The primary indications for ECMO in acute respiratory failure include severe refractory hypoxemic and hypercarbic respiratory failure in spite of maximum lung protective ventilatory support. Various triage criteria have been described and published. Contraindications exist when application of ECMO may be futile or technically impossible. Knowledge and appreciation of the circuit, cannulae, and the physiology of gas exchange with ECMO are necessary to ensure lung rest, efficiency of oxygenation, and ventilation as well as troubleshooting problems. Anticoagulation is a major concern with ECMO, and the evidence is evolving with respect to diagnostic testing and use of anticoagulants. Clinical management of the patient includes comprehensive critical care addressing sedation and neurologic issues, ensuring lung recruitment, diuresis, early enteral nutrition, treatment and surveillance of infections, and multisystem organ support. Newer technology that delinks oxygenation and ventilation by extracorporeal carbon dioxide removal may lead to ultra-lung protective ventilation, avoidance of endotracheal intubation in some situations, and ambulatory therapies as a bridge to lung transplantation. Risks, complications, and long-term outcomes and resources need to be considered and weighed in before widespread application. Ethical challenges are a reality and a multidisciplinary approach that should be adopted for every case in consideration.

  13. Quality assurance applied to Radiological Protection Program of CPHR - Centro de Proteccion Y Higiene de las Radiaciones

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Jova Sed, L.; Domenech Nieves, H.; Hernandez Sainz, A.

    2001-01-01

    The quality assurance in establishment that use ionizing radiation sources, is according to international recommendations of radiation protection programs. This work intends to present the experience of the Centro de Proteccion y Higiene de las Radiaciones (CPHR), in the implementation of requirements of quality in their Radiological Protection Program

  14. Effects of respiratory muscle training (RMT) in children with infantile-onset Pompe disease and respiratory muscle weakness.

    Science.gov (United States)

    Jones, Harrison N; Crisp, Kelly D; Moss, Tronda; Strollo, Katherine; Robey, Randy; Sank, Jeffrey; Canfield, Michelle; Case, Laura E; Mahler, Leslie; Kravitz, Richard M; Kishnani, Priya S

    2014-01-01

    Respiratory muscle weakness is a primary therapeutic challenge for patients with infantile Pompe disease. We previously described the clinical implementation of a respiratory muscle training (RMT) regimen in two adults with late-onset Pompe disease; both demonstrated marked increases in inspiratory and expiratory muscle strength in response to RMT. However, the use of RMT in pediatric survivors of infantile Pompe disease has not been previously reported. We report the effects of an intensive RMT program on maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP) using A-B-A (baseline-treatment-posttest) single subject experimental design in two pediatric survivors of infantile Pompe disease. Both subjects had persistent respiratory muscle weakness despite long-term treatment with alglucosidase alfa. Subject 1 demonstrated negligible to modest increases in MIP/MEP (6% increase in MIP, d=0.25; 19% increase in MEP, d=0.87), while Subject 2 demonstrated very large increases in MIP/MEP (45% increase in MIP, d=2.38; 81% increase in MEP, d=4.31). Following three-month RMT withdrawal, both subjects maintained these strength increases and demonstrated maximal MIP and MEP values at follow-up. Intensive RMT may be a beneficial treatment for respiratory muscle weakness in pediatric survivors of infantile Pompe disease.

  15. Respiratory

    Science.gov (United States)

    The words "respiratory" and "respiration" refer to the lungs and breathing. ... Boron WF. Organization of the respiratory system. In: Boron WF, Boulpaep EL, eds. Medical Physiology . 3rd ed. Philadelphia, PA: Elsevier; 2017:chap 26.

  16. Barriers and facilitators to the dissemination of DECISION+, a continuing medical education program for optimizing decisions about antibiotics for acute respiratory infections in primary care: A study protocol

    Directory of Open Access Journals (Sweden)

    Gagnon Marie-Pierre

    2011-01-01

    Full Text Available Abstract Background In North America, acute respiratory infections are the main reason for doctors' visits in primary care. Family physicians and their patients overuse antibiotics for treating acute respiratory infections. In a pilot clustered randomized trial, we showed that DECISION+, a continuing medical education program in shared decision making, has the potential to reduce the overuse of antibiotics for treating acute respiratory infections. DECISION+ learning activities consisted of three interactive sessions of three hours each, reminders at the point of care, and feedback to doctors on their agreement with patients about comfort with the decision whether to use antibiotics. The objective of this study is to identify the barriers and facilitators to physicians' participation in DECISION+ with the goal of disseminating DECISION+ on a larger scale. Methods/design This descriptive study will use mixed methods and retrospective and prospective components. All analyses will be based on an adapted version of the Ottawa Model of Research Use. First, we will use qualitative methods to analyze the following retrospective data from the pilot study: the logbooks of eight research assistants, the transcriptions of 15 training sessions, and 27 participant evaluations of the DECISION+ training sessions. Second, we will collect prospective data in semi-structured focus groups composed of family physicians to identify barriers and facilitators to the dissemination of a future training program similar to DECISION+. All 39 family physicians exposed to DECISION+ during the pilot project will be eligible to participate. We will use a self-administered questionnaire based on Azjen's Theory of Planned Behaviour to assess participants' intention to take part in future training programs similar to DECISION+. Discussion Barriers and facilitators identified in this project will guide modifications to DECISION+, a continuing medical education program in shared

  17. The respiratory microbiome and respiratory infections

    NARCIS (Netherlands)

    Unger, Stefan A.; Bogaert, Debby

    2017-01-01

    Despite advances over the past ten years lower respiratory tract infections still comprise around a fifth of all deaths worldwide in children under five years of age with the majority in low- and middle-income countries. Known risk factors for severe respiratory infections and poor chronic

  18. Dose response effect of cement dust on respiratory muscles competence in cement mill workers.

    Science.gov (United States)

    Meo, Sultan A; Azeem, Muhammad A; Qureshi, Aijaz A; Ghori, G Moinudin; Al-Drees, Abdul Majeed; Feisal Subhan, Mirza Muhammad

    2006-12-01

    Electromyography (EMG) of respiratory muscles is a reliable method of assessing the ventilatory muscle function, but still its use has not been fully utilized to determine the occupational and environmental hazards on respiratory muscles. Therefore, EMG of intercostal muscles was performed to determine the dose response effect of cement dust on respiratory muscles competence. Matched cross-sectional study of EMG in 50 non-smoking cement mill workers with an age range of 20 - 60 years, who worked without the benefit of cement dust control ventilation or respiratory protective devices. EMG was performed by using surface electrodes and chart recorder. Significant reduction was observed in number of peaks (p competence and stratification of results shows a dose-effect of years of exposure in cement mill.

  19. Is recurrent respiratory infection associated with allergic respiratory disease?

    Science.gov (United States)

    de Oliveira, Tiago Bittencourt; Klering, Everton Andrei; da Veiga, Ana Beatriz Gorini

    2018-03-13

    Respiratory infections cause high morbidity and mortality worldwide. This study aims to estimate the relationship between allergic respiratory diseases with the occurrence of recurrent respiratory infection (RRI) in children and adolescents. The International Study of Asthma and Allergies in Childhood questionnaire and a questionnaire that provides data on the history of respiratory infections and the use of antibiotics were used to obtain data from patients. The relationship between the presence of asthma or allergic rhinitis and the occurrence of respiratory infections in childhood was analyzed. We interviewed the caregivers of 531 children aged 0 to 15 years. The average age of participants was 7.43 years, with females accounting for 52.2%. This study found significant relationship between: presence of asthma or allergic rhinitis with RRI, with prevalence ratio (PR) of 2.47 (1.51-4.02) and 1.61 (1.34-1.93), respectively; respiratory allergies with use of antibiotics for respiratory problems, with PR of 5.32 (2.17-13.0) for asthma and of 1.64 (1.29-2.09) for allergic rhinitis; asthma and allergic rhinitis with diseases of the lower respiratory airways, with PR of 7.82 (4.63-13.21) and 1.65 (1.38-1.96), respectively. In contrast, no relationship between upper respiratory airway diseases and asthma and allergic rhinitis was observed, with PR of 0.71 (0.35-1.48) and 1.30 (0.87-1.95), respectively. RRI is associated with previous atopic diseases, and these conditions should be considered when treating children.

  20. Data on respiratory variables in critically ill patients with acute respiratory failure placed on proportional assist ventilation with load adjustable gain factors (PAV+

    Directory of Open Access Journals (Sweden)

    Dimitris Georgopoulos

    2016-09-01

    Full Text Available The data show respiratory variables in 108 critically ill patients with acute respiratory failure placed on proportional assist ventilation with load adjustable gain factors (PAV+ after at least 36 h on passive mechanical ventilation. PAV+ was continued for 48 h until the patients met pre-defined criteria either for switching to controlled modes or for breathing without ventilator assistance. Data during passive mechanical ventilation and during PAV+ are reported. Data are acquired from the whole population, as well as from patients with and without acute respiratory distress syndrome. The reported variables are tidal volume, driving pressure (ΔP, the difference between static end-inspiratory plateau pressure and positive end-expiratory airway pressure, respiratory system compliance and resistance, and arterial blood gasses. The data are supplemental to our original research article, which described individual ΔP in these patients and examined how it related to ΔP when the same patients were ventilated with passive mechanical ventilation using the currently accepted lung-protective strategy “Driving pressure during assisted mechanical ventilation. Is it controlled by patient brain?” [1]. Keywords: Tidal volume, Compliance, Driving pressure

  1. Permitted decompilation of a computer program in order to protect the general interest

    Directory of Open Access Journals (Sweden)

    Radovanović Sanja M.

    2015-01-01

    Full Text Available Computer program is an intellectual creation protected by copyright. However, unlike other items with equivalent legal protection, a computer program has a strong technical functionality, which is, in nowadays' society, an indispensable factor in everyday business activities, exchange of information, entertainment or achieving other similar purposes. Precisely because of this feature, computer program can rarely be seen in isolation from the hardware and software environment. In other words, the functionality of a computer program reaches its full scope only in interaction with other computer program or device. Bearing in mind the fact that this intellectual creation is in the focus of technological, and thus social, development, legislators are trying to provide a legal framework in which these interactions take place unhindered. In fact, considering that each aspect of the use of a computer program presents the exclusive right of the author, relying on his or her consent to undertake certain perpetration which would provide the necessary connectivity of the various components, could put in risk further technological development. Therefore, the lawmakers provide that, in certain cases and under certain conditions, the author's exclusive right could be restricted or excluded. This paper aims to analyze a normative contribution in achieving, technical and technological needed, and therefore, in terms of general interest justified, interactions.

  2. Implantation and Evaluation of a Training Program in Radiation Protection of the Exposed Workers in our Hospital

    International Nuclear Information System (INIS)

    Gil Agudo, A.; Ruiz Rodriguez, J. C.; Zapata Jimenez, J. C.; Munoz Cuevas, R.; Gil Tomas, S.

    2004-01-01

    The object of this work is to introduce the training program in Radiation Protection implemented in our Hospital, and its evaluation and follow-up. Material AND Methods: The training program in Radiation Protection implanted by the Department of Radiation Protection in the Hospital de la Ribera consists of three types of training modalities: Annual Seminars: applicable to all the exposed workers and divided in a general part and a specific one for each area; Informative lectures: applicable to a specific department, deal with specific issues of interest without predetermined frequency; Individualised training: applicable to pregnant, new workers, job moves and duties change. The follow-up of the program is carried out by mean of inquiries about general and site-specific knowledge on radiation protection. Results The results of the inquiries are analysed and related with the continuous training program. Conclusion: It is remarkable that departments with workers without academic training in radiation protection (Intensive Care Unit, Surgery, Endoscopy,) need a more dedicated training. The results confirm the validity of the three training modalities: The annual seminar provides a continuous training to all exposed workers; the informative lecture is useful to handle immediately issues of current interest in a specific department and the individual training are useful to acquire specific knowledge about radiation risks and radiation protection rules in new working situations. (Author)

  3. Protecting prosecution : Exploring the powers of law in an intervention program for domestic violence

    NARCIS (Netherlands)

    Römkens, R.

    2006-01-01

    This article critically analyzes how the criminal justice system centrally situates itself in an intervention program intended to protect victims of domestic abuse and stalking. Based on the first empirical, in-depth study in the Netherlands of an intervention program using electronic technology

  4. THE ROLE AND PLACE OF INFORMATION PROTECTION IN THE PROGRAM OF TRAINING OF IT-SPECIALISTS

    Directory of Open Access Journals (Sweden)

    Andrey I. Volkov

    2015-01-01

    Full Text Available This article discusses the importance of issues related to the protection of information in the preparation of modern information technology specialists. Notes the importance of studying IT-specialists of this perspective and the need for an integrated approach to the selection and/or development of information security systems. Define the content of training programs on information security, as well as the amount of knowledge in the field of mathematics and information technologies needed for the development of this program. Formulated requirements to the results of development of the program and noted the need to include the protection of information in coursework and final qualifying work.

  5. Climate change and respiratory disease: European Respiratory Society position statement.

    Science.gov (United States)

    Ayres, J G; Forsberg, B; Annesi-Maesano, I; Dey, R; Ebi, K L; Helms, P J; Medina-Ramón, M; Windt, M; Forastiere, F

    2009-08-01

    Climate change will affect individuals with pre-existing respiratory disease, but the extent of the effect remains unclear. The present position statement was developed on behalf of the European Respiratory Society in order to identify areas of concern arising from climate change for individuals with respiratory disease, healthcare workers in the respiratory sector and policy makers. The statement was developed following a 2-day workshop held in Leuven (Belgium) in March 2008. Key areas of concern for the respiratory community arising from climate change are discussed and recommendations made to address gaps in knowledge. The most important recommendation was the development of more accurate predictive models for predicting the impact of climate change on respiratory health. Respiratory healthcare workers also have an advocatory role in persuading governments and the European Union to maintain awareness and appropriate actions with respect to climate change, and these areas are also discussed in the position statement.

  6. 25 CFR 63.35 - How may Indian child protection and family violence prevention program funds be used?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false How may Indian child protection and family violence... INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Indian Child Protection and Family Violence Prevention Program § 63.35 How may Indian child protection and family violence...

  7. Prevalence of Occupational Asthma and Respiratory Symptoms in Foundry Workers

    Directory of Open Access Journals (Sweden)

    Servet Kayhan

    2013-01-01

    Full Text Available This cross-sectional study was conducted in a foundry factory to assess the prevalence of respiratory symptoms and occupational asthma in foundry workers. Physical examination, spirometric evaluation, chest radiograph, and a questionnaire related to respiratory symptoms were performed. Monitoring of peak expiratory flow rates, spirometric reversibility test, and high-resolution computed tomographies were performed for the participants having respiratory symptoms and/or impaired respiratory function test. A total of 347 participants including 286 workers from production department and 61 subjects who worked in nonproduction departments were enrolled in this study. It is found that phlegm (n: 71, 20.46% and cough (n: 52, 14.98% were the most frequent symptoms. The other symptoms were breathlessness (n: 28, 8.06%, chest tightness (n: 14, 4.03%, and wheezing (n: 7, 2.01% . The prevalence of occupational asthma was found to be more frequent among the subjects who worked in the production department (n: 48, 16.78% than the other persons who worked in the nonproduction department (n: 3, 4.91% by chi-square test (P: 0.001. To prevent hazardous respiratory effects of the foundry production, an early diagnosis of occupational asthma is very important. Cessation of cigarette smoking and using of protective masks during the working time should be encouraged.

  8. 10 CFR 35.24 - Authority and responsibilities for the radiation protection program.

    Science.gov (United States)

    2010-01-01

    ...) Radiation protection program changes that do not require a license amendment and are permitted under § 35.26... of the nursing service, and a representative of management who is neither an authorized user nor a...

  9. The host defense peptide beta-defensin 1 confers protection against Bordetella pertussis in newborn piglets.

    Science.gov (United States)

    Elahi, Shokrollah; Buchanan, Rachelle M; Attah-Poku, Sam; Townsend, Hugh G G; Babiuk, Lorne A; Gerdts, Volker

    2006-04-01

    Innate immunity plays an important role in protection against respiratory infections in humans and animals. Host defense peptides such as beta-defensins represent major components of innate immunity. We recently developed a novel porcine model of pertussis, an important respiratory disease of young children and infants worldwide. Here, we investigated the role of porcine beta-defensin 1 (pBD-1), a porcine defensin homologue of human beta-defensin 2, in conferring protection against respiratory infection with Bordetella pertussis. In this model, newborn piglets were fully susceptible to infection and developed severe bronchopneumonia. In contrast, piglets older than 4 weeks of age were protected against infection with B. pertussis. Protection was associated with the expression of pBD-1 in the upper respiratory tract. In fact, pBD-1 expression was developmentally regulated, and the absence of pBD-1 was thought to contribute to the increased susceptibility of newborn piglets to infection with B. pertussis. Bronchoalveolar lavage specimens collected from older animals as well as chemically synthesized pBD-1 displayed strong antimicrobial activity against B. pertussis in vitro. Furthermore, in vivo treatment of newborn piglets with only 500 mug pBD-1 at the time of challenge conferred protection against infection with B. pertussis. Interestingly, pBD-1 displayed no bactericidal activity in vitro against Bordetella bronchiseptica, a closely related natural pathogen of pigs. Our results demonstrate that host defense peptides play an important role in protection against pertussis and are essential in modulating innate immune responses against respiratory infections.

  10. A Respiratory Therapist Disease Management Program for Subjects Hospitalized With COPD.

    Science.gov (United States)

    Silver, Patty C; Kollef, Marin H; Clinkscale, Darnetta; Watts, Peggy; Kidder, Robin; Eads, Brittany; Bennett, Debbie; Lora, Carolyn; Quartaro, Michael

    2017-01-01

    Patients with COPD often require repeated emergency department visits and hospitalizations for COPD exacerbations. Such readmissions increase health-care costs and expose COPD patients to the added risks of nosocomial infections and increased mortality. To determine whether a respiratory therapist (RT) disease management program could reduce re-hospitalization and emergency department visits, a prospective, single-center, unblinded, randomized trial was performed. We enrolled 428 subjects (214 intervention, 214 control). The primary outcome (combined non-hospitalized emergency department visits and hospital readmissions for a COPD exacerbation during the 6-month follow-up) was similar for the study groups (91 vs 159, P = .08). When the 2 components of the primary end point were analyzed individually, the percentage of subjects with non-hospitalized emergency department visits for COPD exacerbations was similar between groups (15.0% vs 15.9%, P = .79). Readmission for a COPD exacerbation was significantly lower in the intervention group (20.1% vs 28.5%, P = .042). The median (interquartile range) duration of hospitalization for a COPD exacerbation was less for the intervention group (5 [3-11] d vs 8 [4-18.5] d, P = .045). In-patient hospital days (306 d vs 523 d, P = .02) and ICU days (17 d vs 53 d, P = .02) due to COPD exacerbations were significantly less for the intervention group. Mortality was similar for both groups (1.4% vs 0.9%, P > .99). Our RT disease management program was associated with less readmission, fewer ICU days, and shorter hospital stays due to COPD exacerbations. Further studies are needed to determine the optimal utilization of RT disease management teams for patients with COPD to optimize outcomes and prevent return hospital visits. (ClinicalTrials.gov registration NCT01543217.). Copyright © 2017 by Daedalus Enterprises.

  11. Port Hope and area property value protection program: creating stability in the marketplace

    International Nuclear Information System (INIS)

    Zelmer, R.

    2003-01-01

    The Property Value Protection (PVP) Program offers an innovative approach to address the risk of individual property value loss resulting from the cleanup and long-term management of low level radioactive waste in the Port Hope area. In its first year of operation, the program has created stability in the marketplace and provided the communities' property owners with the assurance that their investment in their homes and properties will be protected. The PVP Program is part of the Port Hope Area Initiative (the Initiative), encompassing the Port Hope Project for the cleanup of low-level radioactive waste and the development of two long term, low-level radioactive waste management facilities in the Municipality of Port Hope, Ontario. Canada, and the Port Granby Project involving the development of along-term, low-level radioactive waste management facility near Port Granby in the neighbouring Municipality of Clarington. Ontario, Canada. (author)

  12. Application of virtual reality technique to a radiation protection training program

    International Nuclear Information System (INIS)

    Hajek, Brian K.; Kang, Ki Doo; Shin, Yoo Jin; Lee, Yon Sik

    2003-01-01

    Using an Internet Virtual Reality (IVR) technique, a 3-dimensional (3-D) model for the radiation controlled area in a nuclear power plant was developed, and a feasibility study to develop a computational program to estimate radiation dose was performed. For this purpose, a pilot model with a dynamic function and bi-directional communication was developed. This model was enhanced from the existing 3-D single-directional communication. In this pilot model, a plant visitor needs to first pass a series of security checks. If the visitor enters the controlled area and approaches a radiation hazard area, alarms with a warning lamp will be initiated automatically. Throughout the test to connect this model from both domestic and international sites in various time zones, it has proven to perform well. Therefore, this model can be applied to broad fields as radiation protection procedures or radiation protection training with photographic data, and on-line dose assessment programs

  13. Partnering for optimal respiratory home care: physicians working with respiratory therapists to optimally meet respiratory home care needs.

    Science.gov (United States)

    Spratt, G; Petty, T L

    2001-05-01

    The need for respiratory care services continues to increase, reimbursement for those services has decreased, and cost-containment measures have increased the frequency of home health care. Respiratory therapists are well qualified to provide home respiratory care, reduce misallocation of respiratory services, assess patient respiratory status, identify problems and needs, evaluate the effect of the home setting, educate the patient on proper equipment use, monitor patient response to and complications of therapy, monitor equipment functioning, monitor for appropriate infection control procedures, make recommendations for changes to therapy regimen, and adjust therapy under the direction of the physician. Teamwork benefits all parties and offers cost and time savings, improved data collection and communication, higher job satisfaction, and better patient monitoring, education, and quality of life. Respiratory therapists are positioned to optimize treatment efficacy, maximize patient compliance, and minimize hospitalizations among patients receiving respiratory home care.

  14. Pre-natal and post-natal exposure to respiratory infection and atopic diseases development: a historical cohort study

    Directory of Open Access Journals (Sweden)

    Gehring Ulrike

    2006-05-01

    Full Text Available Abstract Background According to the hygiene hypothesis, infections in early life protect from allergic diseases. However, in earlier studies surrogate measures of infection rather than clinical infections were associated with decreased frequencies of atopic diseases. Exposure to infection indicating sub-clinical infection rather than clinical infection might protect from atopic diseases. Objective: to investigate whether exposure to acute respiratory infections within pregnancy and the first year of life is associated with atopic conditions at age 5–14 years and to explore when within pregnancy and the first year of life this exposure is most likely to be protective. Methods Historical cohort study: Population level data on acute respiratory infections from the routine reporting system of the former German Democratic Republic were linked with individual data from consecutive surveys on atopic diseases in the same region (n = 4672. Statistical analyses included multivariate logistic regression analysis and polynomial distributed lag models. Results High exposure to acute respiratory infection between pregnancy and age one year was associated with overall reduced odds of asthma, eczema, hay fever, atopic sensitization and total IgE. Exposure in the first 9 months of life showed the most pronounced effect. Adjusted odds ratio's for asthma, hay fever, inhalant sensitization and total IgE were statistical significantly reduced up to around half. Conclusion Exposure to respiratory infection (most likely indicating sub-clinical infection within pregnancy and the first year of life may be protective in atopic diseases development. The post-natal period thereby seems to be particularly important.

  15. Respiratory care manpower issues.

    Science.gov (United States)

    Mathews, Paul; Drumheller, Lois; Carlow, John J

    2006-03-01

    Although respiratory care is a relatively new profession, its practitioners are deeply involved in providing patient care in the critical care. In preparation for writing this article, we sought to explore the respiratory therapy manpower needs and activities designed to fulfill those needs in critical care practice. We began by delineating the historical development of respiratory care as a profession, the development of its education, and the professional credentialing system. We then conducted several literature reviews with few articles generated. We requested and received data from the American Association for Respiratory Care (AARC), The National Board for Respiratory Care (NBRC), and the Committee on Accreditation of Respiratory Care education (CoARC) relative to their membership, number of credentialed individuals, and educational program student and graduate data for 2000 through 2004. We then conducted two electronic surveys. Survey 1 was a six-item survey that examined the use of mandatory overtime in respiratory care departments. We used a convenience sample of 30 hospitals stratified by size (or=500 beds). Survey 2 was a five-item instrument distributed by blast E-mail to the Society of Critical Care Medicine's Respiratory Care Section members and members of the RC_World list serve. This survey elicited 51 usable and non-duplicative responses from geographically and size-varied institutions. We analyzed these data in several ways from distribution analysis to one-way analysis of variance procedure and appropriate post hoc analysis techniques. Where appropriate, a matched-pairs analysis was performed and these were compared across the variables intensive care unit (ICU) beds per actual number of respiratory care practitioners (RCPs) and ICU beds per preferred number of RCPs. The data gathered from the professional organizations indicated a relatively stable attrition rate (35.2%+/-1.7-3.1%), even in the face of varying enrollments (6,231 in 2004 vs. 4

  16. Enhancement of Immune Memory Responses to Respiratory Infection

    Science.gov (United States)

    2017-08-01

    Unlimited Distribution 13. SUPPLEMENTARY NOTES 14. ABSTRACT Maintenance of long - term immunological memory against pathogens is crucial for the rapid...highly expressed in memory B cells in mice, and Atg7 is required for maintenance of long - term memory B cells needed to protect against influenza...AWARD NUMBER: W81XWH-16-1-0361 TITLE: Enhancement of Immune Memory Responses to Respiratory Infection PRINCIPAL INVESTIGATORs: Dr Farrah

  17. Wackenhut Services, Incorporated: Report from the DOE Voluntary Protection Program onsite review, August 10--14, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This report summarizes the Department of Energy Voluntary Protection Program (DOE-VPP) Review Team`s findings from the five-day onsite evaluation of Wackenhut Services, Inc. (WSI) at Savannah River Site (SRS), conducted August 10-14, 1998. The site was evaluated against the program requirements contained in US Department of Energy Voluntary Protection Program, Part 1: Program Elements to determine its success in implementing the five DOE-VPP tenets. The Team determined that WSI has met in varying degrees, all the tenets of the DOE-VPP. In every case, WSI programs and procedures exceed the level or degree necessary for compliance with existing standards, DOE Orders, and guidelines. In addition, WSI has systematically integrated their occupational safety and health (OSH) program into management and work practices at all levels. WSI`s efforts toward implementing the five major DOE-VPP tenets are summarized.

  18. Wackenhut Services, Incorporated: Report from the DOE Voluntary Protection Program onsite review, August 10-14, 1998

    International Nuclear Information System (INIS)

    1999-05-01

    This report summarizes the Department of Energy Voluntary Protection Program (DOE-VPP) Review Team's findings from the five-day onsite evaluation of Wackenhut Services, Inc. (WSI) at Savannah River Site (SRS), conducted August 10-14, 1998. The site was evaluated against the program requirements contained in US Department of Energy Voluntary Protection Program, Part 1: Program Elements to determine its success in implementing the five DOE-VPP tenets. The Team determined that WSI has met in varying degrees, all the tenets of the DOE-VPP. In every case, WSI programs and procedures exceed the level or degree necessary for compliance with existing standards, DOE Orders, and guidelines. In addition, WSI has systematically integrated their occupational safety and health (OSH) program into management and work practices at all levels. WSI's efforts toward implementing the five major DOE-VPP tenets are summarized

  19. Practical application of computer program Panthere for workers' radiation protection

    International Nuclear Information System (INIS)

    Carlier, Pierre; Michoux, Xavier; Lereculey, Clement

    2014-01-01

    The civil engineering operations to strengthen the raft of Fessenheim's nuclear plant were carried out by EDF. This technical modification has two principles objectives: 1) to increase the thickness of the reactor pit's concrete and 2) to create a new spreading area for corium (by creating a penetration through the wall of the reactor pit). Behind the complex technical operations two radioprotection issues were studied using the computer program 'PANTHERE': 1) Workers' radiation protection during the execution of the work (because of high dose rates in the reactor pit) and 2) operators' radiation protection after the execution of the work. Results contributed to decrease personal and collective dosimetry of operations and to model and design a biological shield to protect workers during Fessenheim reactor operation. (authors)

  20. Collective dose as a performance measure for occupational radiation protection programs: Issues and recommendations

    International Nuclear Information System (INIS)

    Strom, D.J.; Harty, R.; Hickey, E.E.; Martin, J.B.; Peffers, M.S.; Kathren, R.L.

    1998-07-01

    Collective dose is one of the performance measures used at many US Department of Energy (DOE) contractor facilities to quantitatively assess the objectives of the radiation protection program. It can also be used as a management tool to improve the program for keeping worker doses as low as reasonably achievable (ALARA). Collective dose is used here to mean the sum of all total effective dose equivalent values for all workers in a specified group over a specified time. It is often used as a surrogate estimate of radiological risk. In principle, improvements in radiation protection programs and procedures will result in reduction of collective dose, all other things being equal. Within the DOE, most frequently, a single collective dose number, which may or may not be adjusted for workload and other factors, is used as a performance measure for a contractor. The purpose of this report is to evaluate the use of collective dose as a performance measure for ALARA programs at DOE sites

  1. Fusion magnet safety studies program: superconducting magnet protection system and failure. Interim report

    International Nuclear Information System (INIS)

    Allinger, J.; Danby, G.; Hsieh, S.Y.; Keane, J.; Powell, J.; Prodell, A.

    1975-11-01

    This report includes the first two quarters study of available information on schemes for protecting superconducting magnets. These schemes can be divided into two different categories. The first category deals with the detection of faulty regions (or normal regions) in the magnet. The second category relates to the protection of the magnet when a fault is detected, and the derived signal which can be used to activate a safety system (or energy removal system). The general detection and protection methods are first described briefly and then followed by a survey of the protection systems used by different laboratories for various magnets. A survey of the cause of the magnet difficulties or failures is also included. A preliminary discussion of these protection schemes and the experimental development of this program is given

  2. Radiation protection program for early detection of breast cancer in a mammography facility

    International Nuclear Information System (INIS)

    Mariana, Villagomez Casimiro; Cesar, Ruiz Trejo; Ruby, Espejo Fonseca

    2014-01-01

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied

  3. Radiation protection program for early detection of breast cancer in a mammography facility

    Energy Technology Data Exchange (ETDEWEB)

    Mariana, Villagomez Casimiro, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Cesar, Ruiz Trejo, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx [Instituto de Física, UNAM. Cd. Universitaria, CP 04510 (Mexico); Ruby, Espejo Fonseca [Instituto de Enfermedades de la Mama FUCAM-AC, CP 04980 (Mexico)

    2014-11-07

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.

  4. Galacto-Oligosaccharide/Polidextrose Enriched Formula Protects against Respiratory Infections in Infants at High Risk of Atopy: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Giusy Ranucci

    2018-03-01

    Full Text Available Background: Early nutrition affects the risk of atopy and infections through modifications of intestinal microbiota. The Prebiotics in the Prevention of Atopy (PIPA study was a 24-month randomised, double-blind, placebo-controlled trial. It aimed to evaluate the effects of a galacto-oligosaccharide/polydextrose (GOS/PDX-formula (PF on atopic dermatitis (AD and common infections in infants who were born to atopic parents and to investigate the relationship among early nutrition, gut microbiota and clinical outcomes. Methods: A total of 201 and 199 infants were randomized to receive a PF and standard formula (SF, respectively; 140 infants remained on exclusive breastfeeding (BF. Results: The cumulative incidence of AD and its intensity and duration were not statistically different among the three groups. The number of infants with at least one episode of respiratory infection (RI and the mean number of episodes until 48 weeks of age were significantly lower in the PF group than in the SF group. The number of patients with recurrent RIs and incidence of wheezing lower RIs until 96 weeks were lower in the PF group than the SF group, but similar to the BF group. Bifidobacteria and Clostridium cluster I colonization increased over time in the PF group but decreased in the SF and BF groups. Bifidobacteria had a protective role in RIs, whereas Clostridium cluster I was associated with atopy protection. Conclusion: The early administration of PF protects against RIs and mediates a species-specific modulation of the intestinal microbiota. Trial registration: clinicaltrial.gov Identifier: NCT02116452.

  5. A novel anti-influenza copper oxide containing respiratory face mask.

    Directory of Open Access Journals (Sweden)

    Gadi Borkow

    Full Text Available BACKGROUND: Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. METHODOLOGY/PRINCIPAL FINDINGS: We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10TCID(50 of human influenza A virus (H1N1 and avian influenza virus (H9N2, respectively, under simulated breathing conditions (28.3 L/min. Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10TCID(50, while 4.67+/-1.35 log(10TCID(50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10TCID(50 and from the control masks 5.03+/-0.54 log(10TCID(50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. CONCLUSIONS/SIGNIFICANCE: Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical

  6. [The comparison of heparan sulfate and its fragments on the protection against extracellular histones during the pathogenesis of acute respiratory distress syndrome].

    Science.gov (United States)

    Zhang, Y L; Guan, L; Zheng, Y M; Zhao, Z M; Mao, L J; Li, S Q; Zhao, J Y

    2018-01-20

    Objective: In order to explore the role of heparan sulfate (HS) during the pathogenesis of acute respiratory distress syndrome (ARDS) , the protective effect of HS and its fragments against extracellular histones was compared. Methods: Calf thymus histones (CTH) were injected via femoral vein to induce ARDS in rats. HS, HS fragments or saline was intraperitoneally injected (10mg/kg, Q6h, 24h) to test the protective effect against CTH. The ratio of wet/dry lung weight, protein content in bronchoalveolar lavage fluid (BALF) , total leukocyte and neutrophil count in BALF were measured. Results: After CTH injection, the ratio of wet/dry lung weight (5.7±0.95) was much higher than the saline control group (3.1±0.15). The protein content (0.47±0.086mg/ml) , total leukocyte[ (97.4±15.6l) ×10(4)/ml] and neutrophil (18±3.4/LPF) in BALF were obviously increased compared with the saline control group. The intervention of HS evidently decreased ratio of wet/dry lung weight (4.2±0.41) , protein content[ (0.26±0.019) mg/ml], leukocyte[ (61.3±5.74) ×10(4)/ml] and neutrophil (12±1.8/LPF) in BALF. HS fragments also decreased ratio of wet/dry lung weight, protein content, leukocyte and neutrophil count in BALF though the strength was much less than HS. Conclusion: HS and its fragments could provide protection against extracellular histones during the pathogenesis of ARDS. For the protective effect full length HS was much better than HS fragments.

  7. Evasion of Neutrophil Extracellular Traps by Respiratory Pathogens.

    Science.gov (United States)

    Storisteanu, Daniel M L; Pocock, Joanna M; Cowburn, Andrew S; Juss, Jatinder K; Nadesalingam, Angalee; Nizet, Victor; Chilvers, Edwin R

    2017-04-01

    The release of neutrophil extracellular traps (NETs) is a major immune mechanism intended to capture pathogens. These histone- and protease-coated DNA structures are released by neutrophils in response to a variety of stimuli, including respiratory pathogens, and have been identified in the airways of patients with respiratory infection, cystic fibrosis, acute lung injury, primary graft dysfunction, and chronic obstructive pulmonary disease. NET production has been demonstrated in the lungs of mice infected with Staphylococcus aureus, Klebsiella pneumoniae, and Aspergillus fumigatus. Since the discovery of NETs over a decade ago, evidence that "NET evasion" might act as an immune protection strategy among respiratory pathogens, including group A Streptococcus, Bordetella pertussis, and Haemophilus influenzae, has been growing, with the majority of these studies being published in the past 2 years. Evasion strategies fall into three main categories: inhibition of NET release by down-regulating host inflammatory responses; degradation of NETs using pathogen-derived DNases; and resistance to the microbicidal components of NETs, which involves a variety of mechanisms, including encapsulation. Hence, the evasion of NETs appears to be a widespread strategy to allow pathogen proliferation and dissemination, and is currently a topic of intense research interest. This article outlines the evidence supporting the three main strategies of NET evasion-inhibition, degradation, and resistance-with particular reference to common respiratory pathogens.

  8. Social Protection Schemes in Pakistan: assessment of existing programs

    Directory of Open Access Journals (Sweden)

    Yu ShuHong

    2017-07-01

    Full Text Available Social protection is regarded as a basic human right guaranteed in several International Covenants and Treaties. The Constitution of Pakistan exclusively stipulates the provision of social security for all citizens of the country. The aim of the study is to explore and evaluate the social protection schemes with regards to its coverage, scope and outreach. The country has number of social security schemes that are being carried out by provincial and federal governments for the welfare of workers like old age benefits, disablement, health and medical facilities. However, these schemes have failed to extend their benefits to home based, part-time, temporary or contract and agricultural workers. This paper attempts to highlight the shortcomings of existing social protection programs that are obstructing their benefit distribution and limiting their outreach. It underlines the challenges faced by the implementing agencies. This paper also suggests some improvements in the structural design of social security mechanism with special focus on the scope, coverage, outreach and effective delivery mechanism. Since, the proper allocation of resources and effective implementation of these schemes can ensure the assistance and welfare of the targeted population.

  9. A recombinant anchorless respiratory syncytial virus (RSV) fusion (F) protein/monophosphoryl lipid A (MPL) vaccine protects against RSV-induced replication and lung pathology.

    Science.gov (United States)

    Blanco, Jorge C G; Boukhvalova, Marina S; Pletneva, Lioubov M; Shirey, Kari Ann; Vogel, Stefanie N

    2014-03-14

    We previously demonstrated that the severe cytokine storm and pathology associated with RSV infection following intramuscular vaccination of cotton rats with FI-RSV Lot 100 could be completely abolished by formulating the vaccine with the mild TLR4 agonist and adjuvant, monophosphoryl lipid A (MPL). Despite this significant improvement, the vaccine failed to blunt viral replication in the lungs. Since MPL is a weak TLR4 agonist, we hypothesized that its adjuvant activity was mediated by modulating the innate immune response of respiratory tract resident macrophages. Therefore, we developed a new vaccine preparation with purified, baculovirus expressed, partially purified, anchorless RSV F protein formulated with synthetic MPL that was administered to cotton rats intranasally, followed by an intradermal boost. This novel formulation and heterologous "prime/boost" route of administration resulted in decreased viral titers compared to that seen in animals vaccinated with F protein alone. Furthermore, animals vaccinated by this route showed no evidence of enhanced lung pathology upon RSV infection. This indicates that MPL acts as an immune modulator that protects the host from vaccine-enhanced pathology, and reduces RSV replication in the lower respiratory tract when administered by a heterologous prime/boost immunization regimen. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. 25 CFR 63.33 - What must an application for Indian child protection and family violence prevention program funds...

    Science.gov (United States)

    2010-04-01

    ... Child Protection and Family Violence Prevention Program § 63.33 What must an application for Indian... 25 Indians 1 2010-04-01 2010-04-01 false What must an application for Indian child protection and family violence prevention program funds include? 63.33 Section 63.33 Indians BUREAU OF INDIAN AFFAIRS...

  11. [Great depth pneumatic caisson and its load work involved with the efficiency of respiratory protection].

    Science.gov (United States)

    Shibayama, M; Oda, S; Takeuchi, J; Ikeda, Y; Yamamura, I; Mano, Y

    1989-07-01

    Pneumatic caisson work in Japan has been in operation since 1924. Afterward, this technique of compressed air work has been utilized in the constructions like as foundation works, the basements, and shafts of the bottom tunnel or shields for subway and so forth. While, it means for people to be exposed to hyperbaric environment that they use compressed air work, this technique has risks to be suffered from not only decompression sickness (DCS) but toxicity of poisonous gas or oxygen deficiency. However, this technique is necessary for urban civil engineering and recent compressed air works over than 1.0 kg/cm2 has been increased in 1.5 times more than in 1970's and the higher compressed air work more than 4.0 kg/cm2 will be actually planned in near future. So unmanned caisson work is considered as a better technique for such high pressure work, even though people must enter into hyperbaric working fields for maintenance or repair of unmanned operated machinery and materials. This research is to establish the safety work under hyperbaric environment within 7 kg/cm2. It is necessary for us to establish the system not only to keep safety but to maintain working efficiency. According to obtain the purpose, the effect of respiratory protection has been investigated and work load under hyperbaric caisson work has also been studied.

  12. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    2008-11-08

    Nov 8, 2008 ... Pulmonary gas exchange and ventilation were analysed with ... dioxide production (VCO2), minute ventilation (VE), respiratory rate. (fR) and .... Protective masks typically have a dead space of 150 - 500 ml and flow resistance of 8.0. - 10.0 cm H2O∙l-1∙s-1 compared with 70 - 150 ml dead space and 0.6 -.

  13. Evaluating watershed protection programs in New York City's Cannonsville Reservoir source watershed using SWAT-HS

    Science.gov (United States)

    Hoang, L.; Mukundan, R.; Moore, K. E.; Owens, E. M.; Steenhuis, T. S.

    2017-12-01

    New York City (NYC)'s reservoirs supply over one billion gallons of drinking water each day to over nine million consumers in NYC and upstate communities. The City has invested more than $1.5 billion in watershed protection programs to maintain a waiver from filtration for the Catskill and Delaware Systems. In the last 25 years, the NYC Department of Environmental Protection (NYCDEP) has implemented programs in cooperation with upstate communities that include nutrient management, crop rotations, improvement of barnyards and manure storage, implementing tertiary treatment for Phosphorus (P) in wastewater treatment plants, and replacing failed septic systems in an effort to reduce P loads to water supply reservoirs. There have been several modeling studies evaluating the effect of agricultural Best Management Practices (BMPs) on P control in the Cannonsville watershed in the Delaware System. Although these studies showed that BMPs would reduce dissolved P losses, they were limited to farm-scale or watershed-scale estimates of reduction factors without consideration of the dynamic nature of overland flow and P losses from variable source areas. Recently, we developed the process-based SWAT-Hillslope (SWAT-HS) model, a modified version of the Soil and Water Assessment Tool (SWAT) that can realistically predict variable source runoff processes. The objective of this study is to use the SWAT-HS model to evaluate watershed protection programs addressing both point and non-point sources of P. SWAT-HS predicts streamflow very well for the Cannonsville watershed with a daily Nash Sutcliffe Efficiency (NSE) of 0.85 at the watershed outlet and NSE values ranging from 0.56 - 0.82 at five other locations within the watershed. Based on good hydrological prediction, we applied the model to predict P loads using detailed P inputs that change over time due to the implementation of watershed protection programs. Results from P model predictions provide improved projections of P

  14. Respiratory mechanics

    CERN Document Server

    Wilson, Theodore A

    2016-01-01

    This book thoroughly covers each subfield of respiratory mechanics: pulmonary mechanics, the respiratory pump, and flow. It presents the current understanding of the field and serves as a guide to the scientific literature from the golden age of respiratory mechanics, 1960 - 2010. Specific topics covered include the contributions of surface tension and tissue forces to lung recoil, the gravitational deformation of the lung, and the interdependence forces that act on pulmonary airways and blood vessels. The geometry and kinematics of the ribs is also covered in detail, as well as the respiratory action of the external and internal intercostal muscles, the mechanics of the diaphragm, and the quantitative compartmental models of the chest wall is also described. Additionally, flow in the airways is covered thoroughly, including the wave-speed and viscous expiratory flow-limiting mechanisms; convection, diffusion and the stationary front; and the distribution of ventilation. This is an ideal book for respiratory ...

  15. Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy

    International Nuclear Information System (INIS)

    Kang, Dong Im; Jung, Sang Hoon; Kim, Chul Jong; Park, Hee Chul; Choi, Byung Ki

    2015-01-01

    External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40%-60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (0.71 sec), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). This study is

  16. Immunostimulation with oral vaccines for prevention and treatment of respiratory tract infections

    Directory of Open Access Journals (Sweden)

    Robert Szamborski

    2016-03-01

    Full Text Available The respiratory system is susceptible to unfavourable effects of biological and non-biological factors. In the protection against infectious agents, the immune system plays a crucial role thanks to close cooperation of specific (acquired and non-specific (natural, innate immune mechanisms. A non-specific response actively supports specific response mechanisms. This enables effective protection of our body against infections, both at the stage when pathogens reach the organism and after their penetration into tissues. A stimulation with microbial antigens leads to the activation of specific immunity mechanisms: humoral and cell-mediated responses. In the humoral response, specific immunoglobulins of various classes are involved to protect from recurrent infections. The knowledge of immunity development enables immune system stimulation with pharmaceutical products. The most common immunostimulants are non-specific and specific bacterial vaccines. The main goal of vaccines is the protection of healthy individuals against infections. Conventional prophylactic vaccines are immunogenic products. They contain a combination of extracts of various bacteria, usually ones that are aetiological factors of upper respiratory tract infections. Non-specific vaccines are administered to provoke a specific immune response towards antigens contained in the vaccine. They are bacterial immunostimulants acting mainly by stimulation and mobilisation of host defensive mechanisms. They improve antibacterial serum properties by increasing the level of natural antibodies. If needed, these reactions should be easily stimulated by a pathogen present in nature and should effectively neutralize or limit the disease. In patients who have been treated with a non-specific vaccine, decreased numbers of episodes of respiratory tract infections as well lower antibiotic intake were noted.

  17. Incidence of respiratory viruses in Peruvian children with acute respiratory infections.

    Science.gov (United States)

    del Valle Mendoza, Juana; Cornejo-Tapia, Angela; Weilg, Pablo; Verne, Eduardo; Nazario-Fuertes, Ronald; Ugarte, Claudia; del Valle, Luis J; Pumarola, Tomás

    2015-06-01

    Acute respiratory infections are responsible for high morbi-mortality in Peruvian children. However, the etiological agents are poorly identified. This study, conducted during the pandemic outbreak of H1N1 influenza in 2009, aims to determine the main etiological agents responsible for acute respiratory infections in children from Lima, Peru. Nasopharyngeal swabs collected from 717 children with acute respiratory infections between January 2009 and December 2010 were analyzed by multiplex RT-PCR for 13 respiratory viruses: influenza A, B, and C virus; parainfluenza virus (PIV) 1, 2, 3, and 4; and human respiratory syncytial virus (RSV) A and B, among others. Samples were also tested with direct fluorescent-antibodies (DFA) for six respiratory viruses. RT-PCR and DFA detected respiratory viruses in 240 (33.5%) and 85 (11.9%) cases, respectively. The most common etiological agents were RSV-A (15.3%), followed by influenza A (4.6%), PIV-1 (3.6%), and PIV-2 (1.8%). The viruses identified by DFA corresponded to RSV (5.9%) and influenza A (1.8%). Therefore, respiratory syncytial viruses (RSV) were found to be the most common etiology of acute respiratory infections. The authors suggest that active surveillance be conducted to identify the causative agents and improve clinical management, especially in the context of possible circulation of pandemic viruses. © 2015 Wiley Periodicals, Inc.

  18. The microbiota of the respiratory tract : Gatekeeper to respiratory health

    NARCIS (Netherlands)

    Man, Wing Ho; De Steenhuijsen Piters, Wouter A.A.; Bogaert, Debby

    2017-01-01

    The respiratory tract is a complex organ system that is responsible for the exchange of oxygen and carbon dioxide. The human respiratory tract spans from the nostrils to the lung alveoli and is inhabited by niche-specific communities of bacteria. The microbiota of the respiratory tract probably acts

  19. 75 FR 39266 - National Protection and Programs Directorate; National Infrastructure Advisory Council

    Science.gov (United States)

    2010-07-08

    ... Infrastructure Disruptions VII. New Business VIII. Closing Remarks IX. Adjournment Procedural While this meeting... Directorate; National Infrastructure Advisory Council AGENCY: National Protection and Programs Directorate... Infrastructure Advisory Council (NIAC) will meet on Tuesday, July 13, 2010, at the National Press Club's Ballroom...

  20. Innate lymphoid cells: the role in respiratory infections and lung tissue damage.

    Science.gov (United States)

    Głobińska, Anna; Kowalski, Marek L

    2017-10-01

    Innate lymphoid cells (ILCs) represent a diverse family of cells of the innate immune system, which play an important role in regulation of tissue homeostasis, immunity and inflammation. Emerging evidence has highlighted the importance of ILCs in both protective immunity to respiratory infections and their pathological roles in the lungs. Therefore, the aim of this review is to summarize the current knowledge, interpret and integrate it into broader perspective, enabling greater insight into the role of ILCs in respiratory diseases. Areas covered: In this review we highlighted the role of ILCs in the lungs, citing the most recent studies in this area. PubMed searches (2004- July 2017) were conducted using the term 'innate lymphoid cells respiratory viral infections' in combination with other relevant terms including various respiratory viruses. Expert commentary: Since studies of ILCs have opened new areas of investigation, understanding the role of ILCs in respiratory infections may help to clarify the mechanisms underlying viral-induced exacerbations of lung diseases, providing the basis for novel therapeutic strategies. Potential therapeutic targets have already been identified. So far, the most promising strategy is cytokine-targeting, although further clinical trials are needed to verify its effectiveness.

  1. Evaluation of Personal Chemical Vapor Protection for Patrol and Tactical Law Enforcement

    National Research Council Canada - National Science Library

    Fedele, Paul D; Lake, William L; Arca, Victor J; Marshall, Stephen M; Mitchell, David B

    2002-01-01

    ... functions in law enforcement. Various Level C, impermeable and charcoal impregnated, vapor-absorptive, air-permeable protective clothing ensembles, worn with the MSA Millenium respiratory protective mask/butyl hood, and seven-mil...

  2. Respiratory Home Health Care

    Science.gov (United States)

    ... Us Home > Healthy Living > Living With Lung Disease > Respiratory Home Health Care Font: Aerosol Delivery Oxygen Resources ... Teenagers Living With Lung Disease Articles written by Respiratory Experts Respiratory Home Health Care Respiratory care at ...

  3. Does personal experience affect choice-based preferences for wildfire protection programs?

    Science.gov (United States)

    Armando González-Cabán; Thomas P. Holmes; John B. Loomis; José J. Sánchez

    2013-01-01

    In this paper, we investigate homeowner preferences and willingness to pay for wildfire protection programs using a choice experiment with three attributes: risk, loss, and cost. A phone-mail-phone survey was used to collect data from homeowners predominantly living in medium and high wildfire risk communities in Florida. We tested three hypotheses: (1) homeowner...

  4. Acute Respiratory Distress Syndrome

    Directory of Open Access Journals (Sweden)

    Carmen Sílvia Valente Barbas

    2012-01-01

    Full Text Available This paper, based on relevant literature articles and the authors' clinical experience, presents a goal-oriented respiratory management for critically ill patients with acute respiratory distress syndrome (ARDS that can help improve clinicians' ability to care for these patients. Early recognition of ARDS modified risk factors and avoidance of aggravating factors during hospital stay such as nonprotective mechanical ventilation, multiple blood products transfusions, positive fluid balance, ventilator-associated pneumonia, and gastric aspiration can help decrease its incidence. An early extensive clinical, laboratory, and imaging evaluation of “at risk patients” allows a correct diagnosis of ARDS, assessment of comorbidities, and calculation of prognostic indices, so that a careful treatment can be planned. Rapid administration of antibiotics and resuscitative measures in case of sepsis and septic shock associated with protective ventilatory strategies and early short-term paralysis associated with differential ventilatory techniques (recruitment maneuvers with adequate positive end-expiratory pressure titration, prone position, and new extracorporeal membrane oxygenation techniques in severe ARDS can help improve its prognosis. Revaluation of ARDS patients on the third day of evolution (Sequential Organ Failure Assessment (SOFA, biomarkers and response to infection therapy allows changes in the initial treatment plans and can help decrease ARDS mortality.

  5. Effective Respiratory CD8 T-Cell Immunity to Influenza Virus Induced by Intranasal Carbomer-Lecithin-Adjuvanted Non-replicating Vaccines

    Science.gov (United States)

    Gasper, David J.; Neldner, Brandon; Plisch, Erin H.; Rustom, Hani; Imai, Hirotaka; Kawaoka, Yoshihiro; Suresh, M.

    2016-01-01

    CD8+ cytotoxic T lymphocytes (CTLs) are critical for clearing many viral infections, and protective CTL memory can be induced by vaccination with attenuated viruses and vectors. Non-replicating vaccines are typically potentiated by the addition of adjuvants that enhance humoral responses, however few are capable of generating CTL responses. Adjuplex is a carbomer-lecithin-based adjuvant demonstrated to elicit robust humoral immunity to non-replicating antigens. We report that mice immunized with non-replicating Adjuplex-adjuvanted vaccines generated robust antigen-specific CTL responses. Vaccination by the subcutaneous or the intranasal route stimulated systemic and mucosal CTL memory respectively. However, only CTL memory induced by intranasal vaccination was protective against influenza viral challenge, and correlated with an enhancement of memory CTLs in the airways and CD103+ CD69+ CXCR3+ resident memory-like CTLs in the lungs. Mechanistically, Myd88-deficient mice mounted primary CTL responses to Adjuplex vaccines that were similar in magnitude to wild-type mice, but exhibited altered differentiation of effector cell subsets. Immune potentiating effects of Adjuplex entailed alterations in the frequency of antigen-presenting-cell subsets in vaccine draining lymph nodes, and in the lungs and airways following intranasal vaccination. Further, Adjuplex enhanced the ability of dendritic cells to promote antigen-induced proliferation of naïve CD8 T cells by modulating antigen uptake, its intracellular localization, and rate of processing. Taken together, we have identified an adjuvant that elicits both systemic and mucosal CTL memory to non-replicating antigens, and engenders protective CTL-based heterosubtypic immunity to influenza A virus in the respiratory tract. Further, findings presented in this manuscript have provided key insights into the mechanisms and factors that govern the induction and programming of systemic and protective memory CTLs in the

  6. Respiratory Morbidity among Rice Mill Workers in an Urban Area of Burdwan District, West Bengal: A Cross-sectional Study.

    Science.gov (United States)

    Rana, Madhab Ch; Naskar, Somnath; Roy, Ramaprasad; Das, Dilip Kr; Das, Soumya

    2018-01-01

    Rice mill workers constitute a special group from the perspective of occupational health. Unprotected dust exposure among them adversely affects their respiratory health, which needs to be evaluated. Adequate evidence is still lacking in many parts of India including West Bengal. Burdwan is one of the main rice-producing districts in the state with abundant rice mills. The aim of the study was to find out the prevalence and pattern of respiratory morbidity and associated background characteristics of rice mill workers. A descriptive cross-sectional study was conducted at Burdwan municipality area during July-December 2016. Considering 44.2% prevalence, 95% confidence interval, 15% allowable error, 10% non-response, a sample of 252 directly engaged rice mill workers were selected through multistage random sampling. With prior consent, the subjects were interviewed, clinically examined, and underwent spirometry; relevant records were also reviewed using a pre-designed schedule. Any abnormal spirometry finding was considered as respiratory morbidity. Ethical approval was obtained from institutional ethics committee. Data were analyzed using SPSS version 20. Chi-square test and multiple logistic regression were applied. Prevalence of respiratory morbidity was 40.73% with obstructive and restrictive respiratory morbidity being 24.60% and 16.13%, respectively. Non-use of any protective measure, duration (years) of working in rice mill and average daily working hours were significant predictors of respiratory morbidity. Respiratory morbidity is quite high in the area. Proper health education and provision of personal protective equipments need to be provided.

  7. Descriptions of new varieties recently distributed from the Citrus Clonal Protection Program

    Science.gov (United States)

    The Citrus Clonal Protection Program (CCPP) is operated through the Department of Plant Pathology and Microbiology at University of California (UC) Riverside and is funded in large part by The California Citrus Research Board (CRB). The CCPP processes citrus propagative material in two phases. First...

  8. Material protection control and accounting program activities at the Urals electrochemical integrated plant

    International Nuclear Information System (INIS)

    McAllister, S.

    1997-01-01

    The Urals Electrochemical Integrated Plant (UEIP) is the Russian Federation's largest uranium enrichment plant and one of three sites in Russia blending high enriched uranium (HEU) into commercial grade low enriched uranium. UEIP is located approximately 70 km north of Yekaterinburg in the closed city of Novouralsk (formerly Sverdlovsk- 44). DOE's MPC ampersand A program first met with UEIP in June of 1996, however because of some contractual issues the work did not start until September of 1997. The six national laboratories participating in DOE's Material Protection Control and Accounting program are cooperating with UEIP to enhance the capabilities of the physical protection, access control, and nuclear material control and accounting systems. The MPC ampersand A work at UEIP is expected to be completed during fiscal year 2001

  9. Pulmonary rehabilitation improves exercise capacity and dyspnea in air pollution-related respiratory disease.

    Science.gov (United States)

    Miyamoto, Naomi; Senjyu, Hideaki; Tanaka, Takako; Asai, Masaharu; Yanagita, Yorihide; Yano, Yudai; Nishinakagawa, Tsuyoshi; Kotaki, Kenji; Kitagawa, Chika; Rikitomi, Naoto; Kozu, Ryo; Honda, Sumihisa

    2014-01-01

    Air pollution in Japan caused respiratory disease, such as chronic bronchitis and asthma, in many individuals in the 1960s. Although air pollution has decreased, many victims of air pollution-related respiratory disease are limited in their activities of daily living because of respiratory symptoms. The purpose of this study was to evaluate the efficacy of pulmonary rehabilitation in victims of air pollution-related chronic bronchitis or asthma. Subjects were enrolled in a 12-week (2-week inpatient followed by 10-week outpatient) pulmonary rehabilitation program. The program comprised conditioning, strength training, endurance training, and patient education. We assessed the Modified Medical Research Council (MMRC) dyspnea grade, pulmonary function, peripheral muscle force, incremental shuttle walk distance (ISWD), and physical activity at baseline and immediately after the program. Twenty-nine subjects (mean age 74.2 ± 10.1 years, 11 males) completed the program, including 11 subjects with COPD and 18 subjects with asthma. Following rehabilitation, the participants (n = 29) showed significant improvements in MMRC dyspnea grade, vital capacity % predicted, quadriceps force and ISWD (all P pollution-related asthma. In conclusion, we recommend that patients with chronic bronchitis or asthma, resulting from exposure to air pollution, are referred for pulmonary rehabilitation.

  10. Lung recruitment maneuver effects on respiratory mechanics and extravascular lung water index in patients with acute respiratory distress syndrome.

    Science.gov (United States)

    Zhang, Jian-Guo; Chen, Xiao-Juan; Liu, Fen; Zeng, Zhen-Guo; Qian, Ke-Jian

    2011-01-01

    Animal experiments showed that recruitment maneuver (RM) and protective ventilation strategy of the lung could improve oxygenation and reduce extravascular lung water. This study was to investigate the effects of RM on respiratory mechanics and extravascular lung water index (EVLWI) in patients with acute respiratory distress syndrome (ARDS). Thirty patients with ARDS were randomized into a RM group and a non-RM group. In the RM group, after basic mechanical ventilation stabilized for 30 minutes, RM was performed and repeated once every 12 hours for 3 days. In the non-RM group, lung protective strategy was conducted without RM. Oxygenation index (PaO2/FiO2), peak inspiratory pressure (PIP), Plateau pressure (Pplat), static pulmonary compliance (Cst) and EVLWI of patients before treatment and at 12, 24, 48, 72 hours after the treatment were measured and compared between the groups. Hemodynamic changes were observed before and after RM. One-way ANOVA, Student's t test and Fisher's exact test were used to process the data. The levels of PaO2/FiO2 and Cst increased after treatment in the two groups, but they were higher in the RM group than in the non-RM group (P0.05). RM could reduce EVLWI, increase oxygenation and lung compliance. The effect of RM on hemodynamics was transient.

  11. Three Mile Island, Unit 2, radiation protection program: report of the special panel

    International Nuclear Information System (INIS)

    Meinhold, C.B.; Murphy, T.D.; Neely, D.R.; Kathren, R.L.; Rich, B.L.; Stone, G.F.; Casey, W.R.

    1979-12-01

    A special panel was appointed by the Director of Nuclear Reactor Regulation, NRC, to review the radiation protection program at Three Mile Island Unit 2. The Panel confirmed several management and technical deficiencies in the program. Recent major GPU/Met Ed commitments and actions demonstrated a major change in management attitude. The Panel concluded that exposures to personnel can be maintained to as low as is reasonably achievable while limited preparatory recovery work continues and when further needed improvements are implemented as needed, the radiation safety program will be able to support major recovery activities

  12. Three Mile Island, Unit 2, radiation protection program: report of the special panel

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, C. B. [Brookhaven National Lab., Upton, NY (United States); Murphy, T. D. [Nuclear Regulatory Commission, Washington, DC (United States); Neely, D. R. [Nuclear Regulatory Commission, Washington, DC (United States); Kathren, R. L. [Batelle Pacific Northwest Lab. (United States); Rich, B. L. [Exxon Nuclear Idaho Co., Inc. ID (United States); Stone, G. F. [Tennessee Valley Authority, Chattanooga, TN (United States); Casey, W. R. [Brookhaven National Lab., Upton, NY (United States)

    1979-12-01

    A special panel was appointed by the Director of Nuclear Reactor Regulation, NRC, to review the radiation protection program at Three Mile Island Unit 2. The Panel confirmed several management and technical deficiencies in the program. Recent major GPU/Met Ed commitments and actions demonstrated a major change in management attitude. The Panel concluded that exposures to personnel can be maintained to as low as is reasonably achievable while limited preparatory recovery work continues and when further needed improvements are implemented as needed, the radiation safety program will be able to support major recovery activities.

  13. Community-based exercise training for people with chronic respiratory and chronic cardiac disease: a mixed-methods evaluation

    Directory of Open Access Journals (Sweden)

    McNamara RJ

    2016-11-01

    Full Text Available Renae J McNamara,1,2 Zoe J McKeough,3 Laura R Mo,3 Jamie T Dallimore,4 Sarah M Dennis3 1Physiotherapy Department, 2Respiratory and Sleep Medicine Department, Prince of Wales Hospital, Randwick, 3Discipline of Physiotherapy, The University of Sydney, Lidcombe, 4Eastern Sydney Medicare Local, Rosebery, NSW, Australia Background: Poor uptake and adherence are problematic for hospital-based pulmonary and heart failure rehabilitation programs, often because of access difficulties. The aims of this mixed-methods study were to determine the feasibility of a supervised exercise training program in a community gymnasium in people with chronic respiratory and chronic cardiac disease, to explore the experiences of participants and physiotherapists and to determine if a community venue improved access and adherence to rehabilitation. Methods: Adults with chronic respiratory and/or chronic cardiac disease referred to a hospital-based pulmonary and heart failure rehabilitation program were screened to determine their suitability to exercise in a community venue. Eligible patients were offered the opportunity to attend supervised exercise training for 8 weeks in a community gymnasium. Semi-structured interviews were conducted with participants and physiotherapists at the completion of the program. Results: Thirty-one people with chronic respiratory and chronic cardiac disease (34% males, mean [standard deviation] age 72 [10] years commenced the community-based exercise training program. Twenty-two (71% completed the program. All participants who completed the program, and the physiotherapists delivering the program, were highly satisfied, with reports of the community venue being well-equipped, convenient, and easily accessible. Using a community gymnasium promoted a sense of normality and instilled confidence in some to continue exercising at a similar venue post rehabilitation. However, factors such as cost and lack of motivation continue to be barriers

  14. Environmental Compliance and Protection Program Description Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Jacobs

    2009-02-26

    The objective of the Environmental Compliance and Protection (EC and P) Program Description (PD) is to establish minimum environmental compliance requirements and natural resources protection goals for the Bechtel Jacobs Company LLC (BJC) Oak Ridge Environmental Management Cleanup Contract (EMCC) Contract Number DE-AC05-98OR22700-M198. This PD establishes the work practices necessary to ensure protection of the environment during the performance of EMCC work activities on the US Department of Energy's (DOE's) Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee, by BJC employees and subcontractor personnel. Both BJC and subcontractor personnel are required to implement this PD. A majority of the decontamination and demolition (D and D) activities and media (e.g., soil and groundwater) remediation response actions at DOE sites on the ORR are conducted under the authority of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). CERCLA activities are governed by individual CERCLA decision documents (e.g., Record of Decision [ROD] or Action Memorandum) and according to requirements stated in the Federal Facility Agreement for the Oak Ridge Reservation (DOE 1992). Applicable or relevant and appropriate requirements (ARARs) for the selected remedy are the requirements for environmental remediation responses (e.g., removal actions and remedial actions) conducted under CERCLA.

  15. PROTECTING CHILDREN FROM ENVIRONMENTAL THREATS - A CONTINUING EDUCATION PROGRAM FOR NURSES OF THE AMERICAN NURSES FOUNDATION/ASSOCIATION

    Science.gov (United States)

    The American Nurses Association/Foundation will develop online, in print and pre conference continuing education (CE) children's environmental health protection programs to meet the objective of the program. The first CE program is on school environments, the second on home and ...

  16. Pulmonary specialty training to improve respiratory health in low- and middle-income countries. Needs and challenges.

    Science.gov (United States)

    Chakaya, Jeremiah M; Carter, E Jane; Hopewell, Philip C

    2015-04-01

    It is estimated that 85% of the world's population lives in low- and middle-income countries (LMICs). Although economic conditions are improving in these countries, health expenditures have not kept pace with the overall economic growth, and health systems remain weak. These already inadequate systems are being further stressed by the epidemiologic transition that is taking place, characterized by a slow decrease in communicable diseases and an increase in noninfectious chronic diseases, resulting in a "double burden" of infectious and noninfectious diseases. Respiratory diseases comprise the largest category of illness within this combined burden of disease. Although there are chronic respiratory disease programs of proven effectiveness appropriate for LMICs, implementation has been greatly hampered by the lack of physicians who have special knowledge and skills in addressing the full spectrum of lung diseases. Thus, there is an urgent need to create training programs for specialists in respiratory diseases. Such programs should be developed and conducted by institutions in LMICs and tailored to fit the prevailing circumstances of the country. Existing curriculum blueprints may be used to guide training program development with appropriate modifications. Academic institutions and professional societies in high-income countries may be called upon to provide technical assistance in developing and implementing training programs. In order to better define the burden of respiratory diseases and identify effective interventions, research, moved forward by persons committed and specialized in this area of health, will be essential.

  17. Respiratory mechanics in brain injury: A review.

    Science.gov (United States)

    Koutsoukou, Antonia; Katsiari, Maria; Orfanos, Stylianos E; Kotanidou, Anastasia; Daganou, Maria; Kyriakopoulou, Magdalini; Koulouris, Nikolaos G; Rovina, Nikoletta

    2016-02-04

    Several clinical and experimental studies have shown that lung injury occurs shortly after brain damage. The responsible mechanisms involve neurogenic pulmonary edema, inflammation, the harmful action of neurotransmitters, or autonomic system dysfunction. Mechanical ventilation, an essential component of life support in brain-damaged patients (BD), may be an additional traumatic factor to the already injured or susceptible to injury lungs of these patients thus worsening lung injury, in case that non lung protective ventilator settings are applied. Measurement of respiratory mechanics in BD patients, as well as assessment of their evolution during mechanical ventilation, may lead to preclinical lung injury detection early enough, allowing thus the selection of the appropriate ventilator settings to avoid ventilator-induced lung injury. The aim of this review is to explore the mechanical properties of the respiratory system in BD patients along with the underlying mechanisms, and to translate the evidence of animal and clinical studies into therapeutic implications regarding the mechanical ventilation of these critically ill patients.

  18. Respiratory Failure

    Science.gov (United States)

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, ... brain, need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can' ...

  19. Respiratory system

    Science.gov (United States)

    Bartlett, R. G., Jr.

    1973-01-01

    The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.

  20. Initial mechanical ventilator settings and lung protective ventilation in the ED.

    Science.gov (United States)

    Wilcox, Susan R; Richards, Jeremy B; Fisher, Daniel F; Sankoff, Jeffrey; Seigel, Todd A

    2016-08-01

    Mechanical ventilation with low tidal volumes has been shown to improve outcomes for patients both with and without acute respiratory distress syndrome. This study aims to characterize mechanically ventilated patients in the emergency department (ED), describe the initial ED ventilator settings, and assess for associations between lung protective ventilation strategies in the ED and outcomes. This was a multicenter, prospective, observational study of mechanical ventilation at 3 academic EDs. We defined lung protective ventilation as a tidal volume of less than or equal to 8 mL/kg of predicted body weight and compared outcomes for patients ventilated with lung protective vs non-lung protective ventilation, including inhospital mortality, ventilator days, intensive care unit length of stay, and hospital length of stay. Data from 433 patients were analyzed. Altered mental status without respiratory pathology was the most common reason for intubation, followed by trauma and respiratory failure. Two hundred sixty-one patients (60.3%) received lung protective ventilation, but most patients were ventilated with a low positive end-expiratory pressure, high fraction of inspired oxygen strategy. Patients were ventilated in the ED for a mean of 5 hours and 7 minutes but had few ventilator adjustments. Outcomes were not significantly different between patients receiving lung protective vs non-lung protective ventilation. Nearly 40% of ED patients were ventilated with non-lung protective ventilation as well as with low positive end-expiratory pressure and high fraction of inspired oxygen. Despite a mean ED ventilation time of more than 5 hours, few patients had adjustments made to their ventilators. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Equation Discovery for Model Identification in Respiratory Mechanics of the Mechanically Ventilated Human Lung

    Science.gov (United States)

    Ganzert, Steven; Guttmann, Josef; Steinmann, Daniel; Kramer, Stefan

    Lung protective ventilation strategies reduce the risk of ventilator associated lung injury. To develop such strategies, knowledge about mechanical properties of the mechanically ventilated human lung is essential. This study was designed to develop an equation discovery system to identify mathematical models of the respiratory system in time-series data obtained from mechanically ventilated patients. Two techniques were combined: (i) the usage of declarative bias to reduce search space complexity and inherently providing the processing of background knowledge. (ii) A newly developed heuristic for traversing the hypothesis space with a greedy, randomized strategy analogical to the GSAT algorithm. In 96.8% of all runs the applied equation discovery system was capable to detect the well-established equation of motion model of the respiratory system in the provided data. We see the potential of this semi-automatic approach to detect more complex mathematical descriptions of the respiratory system from respiratory data.

  2. The protection system to Brazilian Nuclear Program; O sistema de protecao ao Programa Nuclear Brasileiro

    Energy Technology Data Exchange (ETDEWEB)

    Andreuzza, Mario Giussepp Santezzi Bertottelli [Secretaria de Assuntos Estrategicos (SAE), Brasilia, DF (Brazil)

    1997-12-31

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author) 3 refs., 3 figs.

  3. Respiratory Viruses in Febrile Neutropenic Patients with Respiratory Symptoms

    Directory of Open Access Journals (Sweden)

    Mohsen Meidani

    2018-01-01

    Full Text Available Background: Respiratory infections are a frequent cause of fever in neutropenic patients, whereas respiratory viral infections are not frequently considered as a diagnosis, which causes high morbidity and mortality in these patients. Materials and Methods: This prospective study was performed on 36 patients with neutropenia who admitted to hospital were eligible for inclusion with fever (single temperature of >38.3°C or a sustained temperature of >38°C for more than 1 h, upper and lower respiratory symptoms. Sampling was performed from the throat of the patient by the sterile swab. All materials were analyzed by quantitative real-time multiplex polymerase chain reaction covering the following viruses; influenza, parainfluenza virus (PIV, rhinovirus (RV, human metapneumovirus, and respiratory syncytial virus (RSV. Results: RV was the most frequently detected virus and then RSV was the most. PIV was not present in any of the tested samples. Furthermore, no substantial differences in the distribution of specific viral species were observed based on age, sex, neutropenia duration, hematological disorder, and respiratory tract symptoms and signs (P > 0.05. Conclusion: Our prospective study supports the hypothesis that respiratory viruses play an important role in the development of neutropenic fever, and thus has the potential to individualize infection treatment and to reduce the extensive use of antibiotics in immunocompromised patients with neutropenia.

  4. Web-based system for radiological protection programs: a repository for research, consultation and information

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Denise S.; Sordi, Gian Maria A.A., E-mail: gmsordi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    In order to establish a Radiation Protection Plan or a Radiation Emergency Plan, Brazilian facilities should take into account all procedures based on national and international guidelines and recommendations. This information can be found in several documents published by different organizations over the past decades: the International Commission on Radiological Protection (ICRP), International Atomic Energy Agency (IAEA) and Comissao Nacional de Energia Nuclear (CNEN). Therefore, this project aims the informatization of the radiological protection programs in a single system in order to offer unified programs and inter-related information in Portuguese, providing Brazilian facilities a complete repository for research, consultation and information, combining computer technology and radiological protection in order to enhance the best benefits from information technology. This research work includes programs about: (1) Monitoring of Workplace (Monitoring for External Radiation, Monitoring for Surface Contamination, Monitoring for Air Contamination) and (2) Individual Monitoring (Monitoring of External Exposure and Monitoring of Internal Exposure, Monitoring for Skin and Clothing). WEB platform tools and functionalities were developed according to target public needs, regarding new possibilities of media, mobile access, and information sharing. The servers processing power added to the technology of relational databases allow to integrate information from different sources, enabling complex queries with reduced response time. Moreover, taking into account this is a pioneer project with the prospect of long-term use, the challenge involves the combination of multiple computer technologies that allows a robust, effective and flexible system, which can be easily adapted to future technological innovations. (author)

  5. Web-based system for radiological protection programs: a repository for research, consultation and information

    International Nuclear Information System (INIS)

    Levy, Denise S.; Sordi, Gian Maria A.A.

    2014-01-01

    In order to establish a Radiation Protection Plan or a Radiation Emergency Plan, Brazilian facilities should take into account all procedures based on national and international guidelines and recommendations. This information can be found in several documents published by different organizations over the past decades: the International Commission on Radiological Protection (ICRP), International Atomic Energy Agency (IAEA) and Comissao Nacional de Energia Nuclear (CNEN). Therefore, this project aims the informatization of the radiological protection programs in a single system in order to offer unified programs and inter-related information in Portuguese, providing Brazilian facilities a complete repository for research, consultation and information, combining computer technology and radiological protection in order to enhance the best benefits from information technology. This research work includes programs about: (1) Monitoring of Workplace (Monitoring for External Radiation, Monitoring for Surface Contamination, Monitoring for Air Contamination) and (2) Individual Monitoring (Monitoring of External Exposure and Monitoring of Internal Exposure, Monitoring for Skin and Clothing). WEB platform tools and functionalities were developed according to target public needs, regarding new possibilities of media, mobile access, and information sharing. The servers processing power added to the technology of relational databases allow to integrate information from different sources, enabling complex queries with reduced response time. Moreover, taking into account this is a pioneer project with the prospect of long-term use, the challenge involves the combination of multiple computer technologies that allows a robust, effective and flexible system, which can be easily adapted to future technological innovations. (author)

  6. Middle East Respiratory Syndrome

    Centers for Disease Control (CDC) Podcasts

    2014-07-07

    This podcast discusses Middle East Respiratory Syndrome, or MERS, a viral respiratory illness caused by Middle East Respiratory Syndrome Coronavirus—MERS-CoV.  Created: 7/7/2014 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 7/7/2014.

  7. 75 FR 14454 - National Protection and Programs Directorate; National Infrastructure Advisory Council

    Science.gov (United States)

    2010-03-25

    ..., National Infrastructure Advisory Council. [FR Doc. 2010-6633 Filed 3-24-10; 8:45 am] BILLING CODE 9110-9P-P ... Directorate; National Infrastructure Advisory Council AGENCY: National Protection and Programs Directorate... Infrastructure Advisory Council (NIAC) will meet on Tuesday, April 13, 2010, at the National Press Club's...

  8. Reduction of influenza virus titer and protection against influenza virus infection in infant mice fed Lactobacillus casei Shirota.

    Science.gov (United States)

    Yasui, Hisako; Kiyoshima, Junko; Hori, Tetsuji

    2004-07-01

    We investigated whether oral administration of Lactobacillus casei strain Shirota to neonatal and infant mice ameliorates influenza virus (IFV) infection in the upper respiratory tract and protects against influenza infection. In a model of upper respiratory IFV infection, the titer of virus in the nasal washings of infant mice administered L. casei Shirota (L. casei Shirota group) was significantly (P survival rate of the L. casei Shirota group was significantly (P L. casei Shirota group were significantly greater than those of mice in the control group. These findings suggest that oral administration of L. casei Shirota activates the immature immune system of neonatal and infant mice and protects against IFV infection. Therefore, oral administration of L. casei Shirota may accelerate the innate immune response of the respiratory tract and protect against various respiratory infections in neonates, infants, and children, a high risk group for viral and bacterial infections.

  9. Corrosion Protection of Launch Infrastructure and Hardware Through the Space Shuttle Program

    Science.gov (United States)

    Calle, L. M.

    2011-01-01

    Corrosion, the environmentally induced degradation of materials, has been a challenging and costly problem that has affected NASA's launch operations since the inception of the Space Program. Corrosion studies began at NASA's Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. NASA's KSC Beachside Corrosion Test Site, which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive natural conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. In the years that followed, numerous efforts at KSC identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosiye environment at the launch pads. Knowledge on materials degradation, obtained by facing the highly corrosive conditions of the Space Shuttle launch environment, as well as limitations imposed by the environmental impact of corrosion control, have led researchers at NASA's Corrosion Technology Laboratory to establish a new technology development capability in the area of corrosion prevention, detection, and mitigation at KSC that is included as one of the "highest priority" technologies identified by NASA's integrated technology roadmap. A historical perspective highlighting the challenges encountered in protecting launch infrastructure and hardware from corrosion during the life of the Space Shuttle program and the new technological advances that have resulted from facing the unique and highly corrosive conditions of the Space Shuttle launch environment will be presented.

  10. PRESENCE OF RESPIRATORY VIRUSES IN EQUINES IN BRAZIL

    Directory of Open Access Journals (Sweden)

    Dalva Assunção Portari Mancini

    2014-06-01

    Full Text Available Equines are susceptible to respiratory viruses such as influenza and parainfluenza. Respiratory diseases have adversely impacted economies all over the world. This study was intended to determine the presence of influenza and parainfluenza viruses in unvaccinated horses from some regions of the state of São Paulo, Brazil. Blood serum collected from 72 equines of different towns in this state was tested by hemagglutination inhibition test to detect antibodies for both viruses using the corresponding antigens. About 98.6% (71 and 97.2% (70 of the equines responded with antibody protective titers (≥ 80 HIU/25µL H7N7 and H3N8 subtypes of influenza A viruses, respectively. All horses (72 also responded with protective titers (≥ 80 HIU/25µL against the parainfluenza virus. The difference between mean antibody titers to H7N7 and H3N8 subtypes of influenza A viruses was not statistically significant (p > 0.05. The mean titers for influenza and parainfluenza viruses, on the other hand, showed a statistically significant difference (p < 0.001. These results indicate a better antibody response from equines to parainfluenza 3 virus than to the equine influenza viruses. No statistically significant differences in the responses against H7N7 and H3N8 subtypes of influenza A and parainfluenza 3 viruses were observed according to the gender (female, male or the age (≤ 2 to 20 years-old groups. This study provides evidence of the concomitant presence of two subtypes of the equine influenza A (H7N7 and H3N8 viruses and the parainfluenza 3 virus in equines in Brazil. Thus, it is advisable to vaccinate equines against these respiratory viruses.

  11. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  12. Physical Protection Study of the Radio metallurgy Installation Using SAVIComputer Program

    International Nuclear Information System (INIS)

    Pinitoyo, Andreas

    2000-01-01

    Based on IAEA Recommendation on INFCIR/225/Rev.3 (The Physical Protectionof Nuclear Material), a nuclear installation shall have physical protectionsystem for protection or being secure on sabotage activities in theinstallation and thieve of nuclear materials. The recommendation states therequirements for physical protection of nuclear materials usage, transit andstorage. Radio metallurgy Installation of the Fuel Element and ReprocessingDevelopment Center (BATAN) at Serpong is a nuclear installation for researchon post irradiation of high radioactive spent fuel element, its processingand storage. The installation has risk on threat of a sabotage, which isdominant than thieve. The RMI building was designed and constructed ofphysical protection components and have been integrated with the BATAN Safetyand Security System and the Security Guards functions to be PhysicalProtection System for the RMI. By using the SAVI Computer Program with inputdata from the existing standards, assumptions for detection possibility,delay and response, that will result the probability of interruptions of theworst adversary paths PI = 0.1. These mean that the physical protectionsystems of the RMI shall be upgraded and improved in order to be reliable orbetter if the most of paths to the target PI = 1.0. (author)

  13. Human herpesviruses respiratory infections in patients with acute respiratory distress (ARDS).

    Science.gov (United States)

    Bonizzoli, Manuela; Arvia, Rosaria; di Valvasone, Simona; Liotta, Francesco; Zakrzewska, Krystyna; Azzi, Alberta; Peris, Adriano

    2016-08-01

    Acute respiratory distress syndrome (ARDS) is today a leading cause of hospitalization in intensive care unit (ICU). ARDS and pneumonia are closely related to critically ill patients; however, the etiologic agent is not always identified. The presence of human herpes simplex virus 1, human cytomegalovirus and Epstein-Barr virus in respiratory samples of critically ill patients is increasingly reported even without canonical immunosuppression. The main aim of this study was to better understand the significance of herpesviruses finding in lower respiratory tract of ARDS patients hospitalized in ICU. The presence of this group of herpesviruses, in addition to the research of influenza viruses and other common respiratory viruses, was investigated in respiratory samples from 54 patients hospitalized in ICU, without a known microbiological causative agent. Moreover, the immunophenotype of each patient was analyzed. Herpesviruses DNA presence in the lower respiratory tract seemed not attributable to an impaired immunophenotype, whereas a significant correlation was observed between herpesviruses positivity and influenza virus infection. A higher ICU mortality was significantly related to the presence of herpesvirus infection in the lower respiratory tract as well as to impaired immunophenotype, as patients with poor outcome showed severe lymphopenia, affecting in particular T (CD3+) cells, since the first days of ICU hospitalization. In conclusion, these results indicate that herpesviruses lower respiratory tract infection, which occurs more frequently following influenza virus infection, can be a negative prognostic marker. An independent risk factor for ICU patients with ARDS is an impaired immunophenotype.

  14. Development of deformable moving lung phantom to simulate respiratory motion in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jina [Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Lee, Youngkyu [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 137-701, Seoul (Korea, Republic of); Shin, Hunjoo [Department of Radiation Oncology, Inchoen St. Mary' s Hospital College of Medicine, The Catholic University of Korea, Incheon 403-720 (Korea, Republic of); Ji, Sanghoon [Field Robot R& D Group, Korea Institute of Industrial Technology, Ansan 426-910 (Korea, Republic of); Park, Sungkwang [Department of Radiation Oncology, Busan Paik Hospital, Inje University, Busan 614-735 (Korea, Republic of); Kim, Jinyoung [Department of Radiation Oncology, Haeundae Paik Hospital, Inje University, Busan 612-896 (Korea, Republic of); Jang, Hongseok [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 137-701, Seoul (Korea, Republic of); Kang, Youngnam, E-mail: ynkang33@gmail.com [Department of Radiation Oncology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 137-701, Seoul (Korea, Republic of)

    2016-07-01

    Radiation treatment requires high accuracy to protect healthy organs and destroy the tumor. However, tumors located near the diaphragm constantly move during treatment. Respiration-gated radiotherapy has significant potential for the improvement of the irradiation of tumor sites affected by respiratory motion, such as lung and liver tumors. To measure and minimize the effects of respiratory motion, a realistic deformable phantom is required for use as a gold standard. The purpose of this study was to develop and study the characteristics of a deformable moving lung (DML) phantom, such as simulation, tissue equivalence, and rate of deformation. The rate of change of the lung volume, target deformation, and respiratory signals were measured in this study; they were accurately measured using a realistic deformable phantom. The measured volume difference was 31%, which closely corresponds to the average difference in human respiration, and the target movement was − 30 to + 32 mm. The measured signals accurately described human respiratory signals. This DML phantom would be useful for the estimation of deformable image registration and in respiration-gated radiotherapy. This study shows that the developed DML phantom can exactly simulate the patient's respiratory signal and it acts as a deformable 4-dimensional simulation of a patient's lung with sufficient volume change.

  15. Development of deformable moving lung phantom to simulate respiratory motion in radiotherapy

    International Nuclear Information System (INIS)

    Kim, Jina; Lee, Youngkyu; Shin, Hunjoo; Ji, Sanghoon; Park, Sungkwang; Kim, Jinyoung; Jang, Hongseok; Kang, Youngnam

    2016-01-01

    Radiation treatment requires high accuracy to protect healthy organs and destroy the tumor. However, tumors located near the diaphragm constantly move during treatment. Respiration-gated radiotherapy has significant potential for the improvement of the irradiation of tumor sites affected by respiratory motion, such as lung and liver tumors. To measure and minimize the effects of respiratory motion, a realistic deformable phantom is required for use as a gold standard. The purpose of this study was to develop and study the characteristics of a deformable moving lung (DML) phantom, such as simulation, tissue equivalence, and rate of deformation. The rate of change of the lung volume, target deformation, and respiratory signals were measured in this study; they were accurately measured using a realistic deformable phantom. The measured volume difference was 31%, which closely corresponds to the average difference in human respiration, and the target movement was − 30 to + 32 mm. The measured signals accurately described human respiratory signals. This DML phantom would be useful for the estimation of deformable image registration and in respiration-gated radiotherapy. This study shows that the developed DML phantom can exactly simulate the patient's respiratory signal and it acts as a deformable 4-dimensional simulation of a patient's lung with sufficient volume change.

  16. Creatine and creatine pyruvate reduce hypoxia-induced effects on phrenic nerve activity in the juvenile mouse respiratory system.

    Science.gov (United States)

    Scheer, Monika; Bischoff, Anna M; Kruzliak, Peter; Opatrilova, Radka; Bovell, Douglas; Büsselberg, Dietrich

    2016-08-01

    Adequate concentrations of ATP are required to preserve physiological cell functions and protect tissue from hypoxic damage. Decreased oxygen concentration results in ATP synthesis relying increasingly on the presence of phosphocreatine. The lack of ATP through hypoxic insult to neurons that generate or regulate respiratory function, would lead to the cessation of breathing (apnea). It is not clear whether creatine plays a role in maintaining respiratory phrenic nerve (PN) activity during hypoxic challenge. The aim of the study was to test the effects of exogenously applied creatine or creatine pyruvate in maintaining PN induced respiratory rhythm against the deleterious effects of severe hypoxic insult using Working Heart-Brainstem (WHB) preparations of juvenile Swiss type mice. WHB's were perfused with control perfusate or perfusate containing either creatine [100μM] or creatine pyruvate [100μM] prior to hypoxic challenge and PN activity recorded throughout. Results showed that severe hypoxic challenge resulted in an initial transient increase in PN activity, followed by a reduction in that activity leading to respiratory apnea. The results demonstrated that perfusing the WHB preparation with creatine or creatine pyruvate, significantly reduced the onset of apnea compared to control conditions, with creatine pyruvate being the more effective substance. Overall, creatine and creatine pyruvate each produced time-dependent degrees of protection against severe hypoxic-induced disturbances of PN activity. The underlying protective mechanisms are unknown and need further investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Utilization of the lower inflection point of the pressure-volume curve results in protective conventional ventilation comparable to high frequency oscillatory ventilation in an animal model of acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Felipe S. Rossi

    2008-01-01

    Full Text Available INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O. Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.

  18. Immunobiotic Lactobacillus administered post-exposure averts the lethal sequelae of respiratory virus infection.

    Science.gov (United States)

    Percopo, Caroline M; Rice, Tyler A; Brenner, Todd A; Dyer, Kimberly D; Luo, Janice L; Kanakabandi, Kishore; Sturdevant, Daniel E; Porcella, Stephen F; Domachowske, Joseph B; Keicher, Jesse D; Rosenberg, Helene F

    2015-09-01

    We reported previously that priming of the respiratory tract with immunobiotic Lactobacillus prior to virus challenge protects mice against subsequent lethal infection with pneumonia virus of mice (PVM). We present here the results of gene microarray which document differential expression of proinflammatory mediators in response to PVM infection alone and those suppressed in response to Lactobacillus plantarum. We also demonstrate for the first time that intranasal inoculation with live or heat-inactivated L. plantarum or Lactobacillus reuteri promotes full survival from PVM infection when administered within 24h after virus challenge. Survival in response to L. plantarum administered after virus challenge is associated with suppression of proinflammatory cytokines, limited virus recovery, and diminished neutrophil recruitment to lung tissue and airways. Utilizing this post-virus challenge protocol, we found that protective responses elicited by L. plantarum at the respiratory tract were distinct from those at the gastrointestinal mucosa, as mice devoid of the anti-inflammatory cytokine, interleukin (IL)-10, exhibit survival and inflammatory responses that are indistinguishable from those of their wild-type counterparts. Finally, although L. plantarum interacts specifically with pattern recognition receptors TLR2 and NOD2, the respective gene-deleted mice were fully protected against lethal PVM infection by L. plantarum, as are mice devoid of type I interferon receptors. Taken together, L. plantarum is a versatile and flexible agent that is capable of averting the lethal sequelae of severe respiratory infection both prior to and post-virus challenge via complex and potentially redundant mechanisms. Published by Elsevier B.V.

  19. 28 CFR 79.65 - Proof of nonmalignant respiratory disease.

    Science.gov (United States)

    2010-07-01

    ... expiratory volume in one second (FEV1) and the forced vital capacity (FVC) administered and reported in... Program will treat as equivalent to a diagnosis of pulmonary fibrosis any diagnosis of “restrictive lung... that the claimant contracted a nonmalignant respiratory disease, including pulmonary fibrosis, fibrosis...

  20. Protective clothing use at the Savannah River Plant Nuclear Facility

    International Nuclear Information System (INIS)

    Cabbil, C.C.

    1987-01-01

    The mission of the Savannah River Plant in producing nuclear materials does pose some unique protective clothing and equipment requirements not usually seen in the general industry. In addition to protection from the chemicals and physical agents encountered, radioactive hazards must also be managed. This paper describes the protective clothing and respiratory protection used at SRP, and focuses particularly on the development of a new plastic suit. 5 refs., 7 figs., 3 tabs

  1. Site Protection Program and Progress Report of Ali Observatory, Tibet

    Science.gov (United States)

    Yao, Yongqiang; Zhou, Yunhe; Wang, Xiaohua; He, Jun; Zhou, Shu

    2015-08-01

    The Ali observatory, Tibet, is a promising new site identified through ten year site survey over west China, and it is of significance to establish rules of site protection during site development. The site protection program is described with five aspects: site monitoring, technical support, local government support, specific organization, and public education. The long-term sky brightness monitoring is ready with site testing instruments and basic for light pollution measurement; the monitoring also includes directions of main light sources, providing periodical reports and suggestions for coordinating meetings. The technical supports with institutes and manufacturers help to publish lighting standards and replace light fixtures; the research pays special attention to the blue-rich sources, which impact the important application of high altitude sites. An official leading group towards development and protection of astronomical resources has been established by Ali government; one of its tasks is to issue regulations against light pollution, including special restrictions of airport, mine, and winter heating, and to supervise lighting inspection and rectification. A site protection office under the official group and local astronomical society are organized by Ali observatory; the office can coordinate in government levels and promote related activities. A specific website operated by the protection office releases activity propaganda, evaluation results, and technical comparison with other observatories. Both the site protection office and Ali observatory take responsibility for public education, including popular science lectures, light pollution and energy conservation education. Ali Night Sky Park has been constructed and opens in 2014, and provides a popular place and observational experience. The establishment of Ali Observatory and Night Sky Park brings unexpected social influence, and the starry sky trip to Ali becomes a new format of culture

  2. One more brick in the wall of protective ventilation in surgical patients

    NARCIS (Netherlands)

    Filho, Roberto Rabello; Serpa Neto, Ary

    2015-01-01

    On June 14, 2015, Ladha and colleagues published an article in the BMJ entitled "Intraoperative protective mechanical ventilation and risk of postoperative respiratory complications: hospital based registry study", which investigated the effects of intraoperative protective ventilation on major

  3. Afferent Neural Feedback Overrides the Modulating Effects of Arousal, Hypercapnia and Hypoxemia on Neonatal Cardio-respiratory Control.

    Science.gov (United States)

    Lumb, Kathleen J; Schneider, Jennifer M; Ibrahim, Thowfique; Rigaux, Anita; Hasan, Shabih U

    2018-04-20

    study provides the much needed physiologic evidence that profound apneas and life-threatening respiratory failure in vagally denervated animals do not result from lack of arousal or hypoxemia. Rather, change in sleep state and concomitant respiratory depression result from lack of afferent volume feedback, which appears to be critical for the maintenance of normal breathing patterns and adequate gas exchange during the early postnatal period. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Computerized Respiratory Sounds: Novel Outcomes for Pulmonary Rehabilitation in COPD.

    Science.gov (United States)

    Jácome, Cristina; Marques, Alda

    2017-02-01

    Computerized respiratory sounds are a simple and noninvasive measure to assess lung function. Nevertheless, their potential to detect changes after pulmonary rehabilitation (PR) is unknown and needs clarification if respiratory acoustics are to be used in clinical practice. Thus, this study investigated the short- and mid-term effects of PR on computerized respiratory sounds in subjects with COPD. Forty-one subjects with COPD completed a 12-week PR program and a 3-month follow-up. Secondary outcome measures included dyspnea, self-reported sputum, FEV 1 , exercise tolerance, self-reported physical activity, health-related quality of life, and peripheral muscle strength. Computerized respiratory sounds, the primary outcomes, were recorded at right/left posterior chest using 2 stethoscopes. Air flow was recorded with a pneumotachograph. Normal respiratory sounds, crackles, and wheezes were analyzed with validated algorithms. There was a significant effect over time in all secondary outcomes, with the exception of FEV 1 and of the impact domain of the St George Respiratory Questionnaire. Inspiratory and expiratory median frequencies of normal respiratory sounds in the 100-300 Hz band were significantly lower immediately (-2.3 Hz [95% CI -4 to -0.7] and -1.9 Hz [95% CI -3.3 to -0.5]) and at 3 months (-2.1 Hz [95% CI -3.6 to -0.7] and -2 Hz [95% CI -3.6 to -0.5]) post-PR. The mean number of expiratory crackles (-0.8, 95% CI -1.3 to -0.3) and inspiratory wheeze occupation rate (median 5.9 vs 0) were significantly lower immediately post-PR. Computerized respiratory sounds were sensitive to short- and mid-term effects of PR in subjects with COPD. These findings are encouraging for the clinical use of respiratory acoustics. Future research is needed to strengthen these findings and explore the potential of computerized respiratory sounds to assess the effectiveness of other clinical interventions in COPD. Copyright © 2017 by Daedalus Enterprises.

  5. Respiratory morbidity associated with exposure to particulate matter in the environment

    Directory of Open Access Journals (Sweden)

    Elkin Martínez. L

    2011-11-01

    Full Text Available Introduction: it is assumed that prolonged exposure to airborne pollutants in the areas where people live or work can affect their respiratory systems. In order to demand for control measures aimed at protecting the community’s health, it is necessary to provide evidence for this claim. Methods: the respiratory morbidity of people living or working in urban areas of Medellín was analyzed (high particulate matter pollution. The average of PM10 is 60 µg/m3 and then compared with the respiratory morbidity of a matched sample of inhabitants living in the municipalities located in eastern Antioquia (low pollution. The average of PM10 is 30 µg/m3. Results: the groups that were compared were similar with respect to sociodemographic and other potential confounding variables. Upon comparing the two groups, a higher risk of respiratory signs and symptoms can be observed for subjects from the urban areas of Medellín. Nasal congestion, respiratory distress, and cough are the symptoms that occur in sharper contrast with relative risk of 2.60 95% CI (1.93, 3.62; 2.22 95% CI (1.56, 3.15 and 2.14 95% CI (1.63, 2.81 respectively. Conclusion: high pm10 levels as an indicator of air pollution in urban environments where people live and work contribute to a higher risk of respiratory disease. This implies adverse consequences both in economic and social terms. The control of such a situation hence becomes a social and professional priority.

  6. Installation Restoration Program. Phase 2 - Confirmation/ Quantification. Stage 2 for McChord Air Force Base, Washington

    Science.gov (United States)

    1986-04-30

    canadensis), beaver (Castor canadensis), muskrat (Ondatra zibethica), and mink ( Mustela vison ). Mule or blacktail deer (Oedocoileus hemionus), raccoon...aprons, blouse, trousers) C. Respiratory protection using half-facepiece air purifying res- pirator with replaceable filter cartridges 1...Hierarchy of protective controls: engineered, admini- strative, work practice, personal protective clothing and eq- ^.pment. J-6 2. Forms of respiratory

  7. A pilot survey on the quality of life in respiratory rehabilitation carried out in COPD patients with severe respiratory failure: preliminary data of a novel Inpatient Respiratory Rehabilitation Questionnaire (IRRQ

    Directory of Open Access Journals (Sweden)

    Pasqua Franco

    2012-11-01

    Full Text Available Abstract Background Measuring the state of health is a method for quantifying the impact of an illness on the day-to-day life, health and wellbeing of a patient, providing a quantitative measure of an individual’s quality of life (QoL. QoL expresses patient point of view by a subjective dimension and can express the results of medical intervention. Pulmonary rehabilitation is an essential component in the management of COPD patients, and measuring QoL has become a central focus in the study of this disease. Although nowadays several questionnaires for measuring the QoL in COPD patients are available, there are no questionnaires specifically developed for evaluating QoL in COPD patients undergoing respiratory rehabilitation. The aim of this study was to develop a novel questionnaire for the QoL quantification in COPD patients undergoing in-patient pulmonary rehabilitation program. Methods The questionnaire, administered to COPD patients undergoing long-term oxygen therapy into a respiratory rehabilitation ward, was developed by a simple and graphic layout to be administered to elderly patients. It included one form for admission and another for discharge. It included only tips related to the subjective components of QoL that would be relevant for patient, although likely not strictly related to the respiratory function. A descriptive analysis was performed for the socio-demographic characteristics and both the non-parametric Wilcoxon T-test and the Cronbach’s alpha index were calculated for evaluating the sensitivity of the questionnaire to the effects of respiratory rehabilitation and for identifying its consistency. Results The physical and psychological condition of the 34 COPD patients improved after the rehabilitative treatment and this finding was detected by the questionnaire (overall improvement: 14.2±2.5%, as confirmed by the non-parametric Wilcoxon test (p Conclusions This proposed questionnaire represents a substantial innovation

  8. Radiological Threat Reduction (RTR) program: implementing physical security to protect large radioactive sources worldwide

    International Nuclear Information System (INIS)

    Lowe, Daniel L.

    2004-01-01

    The U.S. Department of Energy's Radiological Threat Reduction (RTR) Program strives to reduce the threat of a Radiological Dispersion Device (RDD) incident that could affect U.S. interests worldwide. Sandia National Laboratories supports the RTR program on many different levels. Sandia works directly with DOE to develop strategies, including the selection of countries to receive support and the identification of radioactive materials to be protected. Sandia also works with DOE in the development of guidelines and in training DOE project managers in physical protection principles. Other support to DOE includes performing rapid assessments and providing guidance for establishing foreign regulatory and knowledge infrastructure. Sandia works directly with foreign governments to establish cooperative agreements necessary to implement the RTR Program efforts to protect radioactive sources. Once necessary agreements are in place, Sandia works with in-country organizations to implement various security related initiatives, such as installing security systems and searching for (and securing) orphaned radioactive sources. The radioactive materials of interest to the RTR program include Cobalt 60, Cesium 137, Strontium 90, Iridium 192, Radium 226, Plutonium 238, Americium 241, Californium 252, and Others. Security systems are implemented using a standardized approach that provides consistency through out the RTR program efforts at Sandia. The approach incorporates a series of major tasks that overlap in order to provide continuity. The major task sequence is to: Establish in-country contacts - integrators, Obtain material characterizations, Perform site assessments and vulnerability assessments, Develop upgrade plans, Procure and install equipment, Conduct acceptance testing and performance testing, Develop procedures, and Conduct training. Other tasks are incorporated as appropriate and commonly include such as support of reconfiguring infrastructure, and developing security

  9. Neonatal respiratory distress syndrome

    Science.gov (United States)

    Hyaline membrane disease (HMD); Infant respiratory distress syndrome; Respiratory distress syndrome in infants; RDS - infants ... improves slowly after that. Some infants with severe respiratory distress syndrome will die. This most often occurs ...

  10. Activation of respiratory muscles during respiratory muscle training.

    Science.gov (United States)

    Walterspacher, Stephan; Pietsch, Fabian; Walker, David Johannes; Röcker, Kai; Kabitz, Hans-Joachim

    2018-01-01

    It is unknown which respiratory muscles are mainly activated by respiratory muscle training. This study evaluated Inspiratory Pressure Threshold Loading (IPTL), Inspiratory Flow Resistive Loading (IFRL) and Voluntary Isocapnic Hyperpnea (VIH) with regard to electromyographic (EMG) activation of the sternocleidomastoid muscle (SCM), parasternal muscles (PARA) and the diaphragm (DIA) in randomized order. Surface EMG were analyzed at the end of each training session and normalized using the peak EMG recorded during maximum inspiratory maneuvers (Sniff nasal pressure: SnPna, maximal inspiratory mouth occlusion pressure: PImax). 41 healthy participants were included. Maximal activation was achieved for SCM by SnPna; the PImax activated predominantly PARA and DIA. Activations of SCM and PARA were higher in IPTL and VIH than for IFRL (p<0.05). DIA was higher applying IPTL compared to IFRL or VIH (p<0.05). IPTL, IFRL and VIH differ in activation of inspiratory respiratory muscles. Whereas all methods mainly stimulate accessory respiratory muscles, diaphragm activation was predominant in IPTL. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification

    Science.gov (United States)

    Wang, Shouyi; Bowen, Stephen R.; Chaovalitwongse, W. Art; Sandison, George A.; Grabowski, Thomas J.; Kinahan, Paul E.

    2014-02-01

    The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUVpeak) over lesions of interest. Relative differences in SUVpeak between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUVpeak values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation

  12. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification

    International Nuclear Information System (INIS)

    Wang, Shouyi; Chaovalitwongse, W Art; Bowen, Stephen R; Kinahan, Paul E; Sandison, George A; Grabowski, Thomas J

    2014-01-01

    The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV peak ) over lesions of interest. Relative differences in SUV peak between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV peak values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion

  13. What Is Respiratory Distress Syndrome?

    Science.gov (United States)

    ... Home / Respiratory Distress Syndrome Respiratory Distress Syndrome Also known as What Is Respiratory ... This condition is called apnea (AP-ne-ah). Respiratory Distress Syndrome Complications Depending on the severity of ...

  14. Neurological Respiratory Failure

    Directory of Open Access Journals (Sweden)

    Mohan Rudrappa

    2018-01-01

    Full Text Available West Nile virus infection in humans is mostly asymptomatic. Less than 1% of neuro-invasive cases show a fatality rate of around 10%. Acute flaccid paralysis of respiratory muscles leading to respiratory failure is the most common cause of death. Although the peripheral nervous system can be involved, isolated phrenic nerve palsy leading to respiratory failure is rare and described in only two cases in the English literature. We present another case of neurological respiratory failure due to West Nile virus-induced phrenic nerve palsy. Our case reiterates the rare, but lethal, consequences of West Nile virus infection, and the increase of its awareness among physicians.

  15. Severe acute respiratory syndrome (SARS)

    Science.gov (United States)

    SARS; Respiratory failure - SARS ... Complications may include: Respiratory failure Liver failure Heart failure ... 366. McIntosh K, Perlman S. Coronaviruses, including severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS). ...

  16. Mechanical Ventilation during Extracorporeal Membrane Oxygenation in Patients with Acute Severe Respiratory Failure.

    Science.gov (United States)

    Zhang, Zhongheng; Gu, Wan-Jie; Chen, Kun; Ni, Hongying

    2017-01-01

    Conventionally, a substantial number of patients with acute respiratory failure require mechanical ventilation (MV) to avert catastrophe of hypoxemia and hypercapnia. However, mechanical ventilation per se can cause lung injury, accelerating the disease progression. Extracorporeal membrane oxygenation (ECMO) provides an alternative to rescue patients with severe respiratory failure that conventional mechanical ventilation fails to maintain adequate gas exchange. The physiology behind ECMO and its interaction with MV were reviewed. Next, we discussed the timing of ECMO initiation based on the risks and benefits of ECMO. During the running of ECMO, the protective ventilation strategy can be employed without worrying about catastrophic hypoxemia and carbon dioxide retention. There is a large body of evidence showing that protective ventilation with low tidal volume, high positive end-expiratory pressure, and prone positioning can provide benefits on mortality outcome. More recently, there is an increasing popularity on the use of awake and spontaneous breathing for patients undergoing ECMO, which is thought to be beneficial in terms of rehabilitation.

  17. Mechanical Ventilation during Extracorporeal Membrane Oxygenation in Patients with Acute Severe Respiratory Failure

    Directory of Open Access Journals (Sweden)

    Zhongheng Zhang

    2017-01-01

    Full Text Available Conventionally, a substantial number of patients with acute respiratory failure require mechanical ventilation (MV to avert catastrophe of hypoxemia and hypercapnia. However, mechanical ventilation per se can cause lung injury, accelerating the disease progression. Extracorporeal membrane oxygenation (ECMO provides an alternative to rescue patients with severe respiratory failure that conventional mechanical ventilation fails to maintain adequate gas exchange. The physiology behind ECMO and its interaction with MV were reviewed. Next, we discussed the timing of ECMO initiation based on the risks and benefits of ECMO. During the running of ECMO, the protective ventilation strategy can be employed without worrying about catastrophic hypoxemia and carbon dioxide retention. There is a large body of evidence showing that protective ventilation with low tidal volume, high positive end-expiratory pressure, and prone positioning can provide benefits on mortality outcome. More recently, there is an increasing popularity on the use of awake and spontaneous breathing for patients undergoing ECMO, which is thought to be beneficial in terms of rehabilitation.

  18. The Role of Human Milk Immunomodulators in Protecting Against Viral Bronchiolitis and Development of Chronic Wheezing Illness.

    Science.gov (United States)

    Dixon, Dani-Louise

    2015-07-07

    Infants who are breastfed are at an immunological advantage when compared with formula fed infants, evidenced by decreased incidence of infections and diminished propensity for long term conditions, including chronic wheeze and/or asthma. Exclusive breastfeeding reduces the duration of hospital admission, risk of respiratory failure and requirement for supplemental oxygen in infants hospitalised with bronchiolitis suggesting a potentially protective mechanism. This review examines the evidence and potential pathways for protection by immunomodulatory factors in human milk against the most common viral cause of bronchiolitis, respiratory syncytial virus (RSV), and subsequent recurrent wheeze in infants. Further investigations into the interplay between respiratory virus infections such as RSV and how they affect, and are affected by, human milk immunomodulators is necessary if we are to gain a true understanding of how breastfeeding protects many infants but not all against infections, and how this relates to long-term protection against conditions such as chronic wheezing illness or asthma.

  19. Advances in mechanical ventilation and pulmonary research for the enhancement of preterm and premature infant respiratory assistance

    OpenAIRE

    Silverii, Adam Phillip

    2017-01-01

    Chronic lung disease in premature and preterm infancy occurs due to the physiology of the underdeveloped pulmonary system. Therefore it is generally accepted that preterm and premature infants need significant respiratory support and a lung-protective strategy, starting from the delivery room where an inadequate respiratory approach may result in a poor outcome. However, there has been evidence to show that mechanical ventilation may aggravate or even cause lung disease if it is not expert...

  20. Childhood Acute Respiratory Infections and Household Environment in an Eastern Indonesian Urban Setting

    Directory of Open Access Journals (Sweden)

    Tomoyuki Shibata

    2014-11-01

    Full Text Available This pilot study evaluated the potential effect of household environmental factors such as income, maternal characteristics, and indoor air pollution on children’s respiratory status in an Eastern Indonesian community. Household data were collected from cross-sectional (n = 461 participants and preliminary childhood case-control surveys (pneumonia cases = 31 diagnosed within three months at a local health clinic; controls = 30. Particulate matter (PM2.5 and PM10 was measured in living rooms, kitchens, children’s bedrooms, and outside areas in close proximity once during the case-control household interviews (55 homes and once per hour from 6 a.m. to midnight in 11 homes. The household survey showed that children were 1.98 times (p = 0.02 more likely to have coughing symptoms indicating respiratory infection, if mothers were not the primary caregivers. More children exhibited coughing if they were not exclusively breastfed (OR = 2.18; p = 0.06 or there was a possibility that their mothers were exposed to environmental tobacco smoke during pregnancy (OR = 2.05; p = 0.08. This study suggests that household incomes and mother’s education have an indirect effect on childhood pneumonia and respiratory illness. The concentrations of PM2.5 and PM10 ranged from 0.5 to 35.7 µg/m3 and 7.7 to 575.7 µg/m3, respectively, based on grab samples. PM was significantly different between the case and control groups (p < 0.01. The study also suggests that ambient air may dilute indoor pollution, but also introduces pollution into the home from the community environment. Effective intervention programs need to be developed that consider multiple direct and indirect risk factors to protect children.

  1. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... of our study was to compare the resulting imaging quality by the use of a time-based respiratory gating system in two groups administered either adenosine or dipyridamole as the pharmacological stress agent. METHODS AND RESULTS: Forty-eight patients were randomized to adenosine or dipyridamole cardiac...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4...

  2. Respiratory and metabolic acidosis differentially affect the respiratory neuronal network in the ventral medulla of neonatal rats.

    Science.gov (United States)

    Okada, Yasumasa; Masumiya, Haruko; Tamura, Yoshiyasu; Oku, Yoshitaka

    2007-11-01

    Two respiratory-related areas, the para-facial respiratory group/retrotrapezoid nucleus (pFRG/RTN) and the pre-Bötzinger complex/ventral respiratory group (preBötC/VRG), are thought to play key roles in respiratory rhythm. Because respiratory output patterns in response to respiratory and metabolic acidosis differ, we hypothesized that the responses of the medullary respiratory neuronal network to respiratory and metabolic acidosis are different. To test these hypotheses, we analysed respiratory-related activity in the pFRG/RTN and preBötC/VRG of the neonatal rat brainstem-spinal cord in vitro by optical imaging using a voltage-sensitive dye, and compared the effects of respiratory and metabolic acidosis on these two populations. We found that the spatiotemporal responses of respiratory-related regional activities to respiratory and metabolic acidosis are fundamentally different, although both acidosis similarly augmented respiratory output by increasing respiratory frequency. PreBötC/VRG activity, which is mainly inspiratory, was augmented by respiratory acidosis. Respiratory-modulated pixels increased in the preBötC/VRG area in response to respiratory acidosis. Metabolic acidosis shifted the respiratory phase in the pFRG/RTN; the pre-inspiratory dominant pattern shifted to inspiratory dominant. The responses of the pFRG/RTN activity to respiratory and metabolic acidosis are complex, and involve either augmentation or reduction in the size of respiratory-related areas. Furthermore, the activation pattern in the pFRG/RTN switched bi-directionally between pre-inspiratory/inspiratory and post-inspiratory. Electrophysiological study supported the results of our optical imaging study. We conclude that respiratory and metabolic acidosis differentially affect activities of the pFRG/RTN and preBötC/VRG, inducing switching and shifts of the respiratory phase. We suggest that they differently influence the coupling states between the pFRG/RTN and preBötC/VRG.

  3. Lungs and Respiratory System

    Science.gov (United States)

    ... Videos for Educators Search English Español Lungs and Respiratory System KidsHealth / For Parents / Lungs and Respiratory System ... ll have taken at least 600 million breaths. Respiratory System Basics All of this breathing couldn't ...

  4. LLNL Radiation Protection Program (RPP) Rev 9.2, Implementation of 10 CFR 835, 'Occupational Radiation Protection'

    Energy Technology Data Exchange (ETDEWEB)

    Shingleton, K. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-06-15

    The Department of Energy (DOE) originally issued Part 10 CFR 835, Occupational Radiation Protection, on January 1, 1994. This regulation, hereafter referred to as “the Rule”, required DOE contractors to develop and maintain a DOE-approved Radiation Protection Program (RPP); DOE approved the initial Lawrence Livermore National Laboratory (LLNL) RPP (Rev 2) on 6/29/95. DOE issued a revision to the Rule on December 4, 1998 and approved LLNL’s revised RPP (Rev 7.1) on 11/18/99. DOE issued a second Rule revision on June 8, 2007 (effective July 9, 2007) and on June 13, 2008 approved LLNL’s RPP (Rev 9.0) which contained plans and measures for coming into compliance with the 2007 Rule changes. DOE issued a correction to the Rule on April 21, 2009.

  5. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC MONITORING TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This technology ...

  6. Effect of transoral tracheal wash on respiratory mechanics in dogs with respiratory disease.

    Science.gov (United States)

    Vaught, Meghan E; Rozanski, Elizabeth A; deLaforcade, Armelle M

    2018-01-01

    The purpose of this study was to determine the impact of a transoral tracheal wash (TOTW) on respiratory mechanics in dogs and to describe the use of a critical care ventilator (CCV) to determine respiratory mechanics. Fourteen client-owned dogs with respiratory diseases were enrolled. Respiratory mechanics, including static compliance (C stat ) and static resistance (R stat ), were determined before and after TOTW. Pre- and post-wash results were compared, with a P -value of mechanics, as observed by a reduction in C stat , presumably due to airway flooding and collapse. While no long-lasting effects were noted in these clinical patients, this effect should be considered when performing TOTW on dogs with respiratory diseases. Respiratory mechanics testing using a CCV was feasible and may be a useful clinical testing approach.

  7. Microbial flora variations in the respiratory tract of mice

    Directory of Open Access Journals (Sweden)

    Rosa Cangemi de Gutierrez

    1999-09-01

    Full Text Available A stable microbial system in the respiratory tract acts as an important defense mechanism against pathogenic microorganisms. Perturbations in this system may allow pathogens to establish. In an ecological environment such as the respiratory tract, there are many diverse factors that play a role in the establishment of the indigenous flora. In the present work we studied the normal microbial flora of different areas of the respiratory tract of mice and their evolution from the time the mice were born. Our interest was to know which were the dominant groups of microorganisms in each area, which were the first capable of colonizing and which dominated over time to be used as probiotic microorganisms. Our results show that Gram negative facultatively anaerobic bacilli and strict anaerobic microorganisms were the last ones to appear in the bronchia, while aerobic and Gram positive cocci were present in all the areas of the respiratory tract. The number of facultative aerobes and strict anaerobes were similar in the nasal passage, pharynx instilled and trachea, but lower in bronchia. The dominant species were Streptococcus viridans and Staphylococcus saprophyticcus, followed by S. epidermidis, Lactobacilli and S. cohnii I which were present on every studied days but at different proportions. This paper is the first part of a research topic investigating the protective effect of the indigenous flora against pathogens using the mice as an experimental model.

  8. A complete audit cycle to assess adherence to a lung protective ventilation strategy.

    Science.gov (United States)

    Joynes, Emma; Dalay, Satinder; Patel, Jaimin M; Fayek, Samia

    2014-11-01

    There is clear evidence for the use of a protective ventilation protocol in patients with acute respiratory distress syndrome (ARDS). There is evidence to suggest that protective ventilation is beneficial in patients at risk of ARDS. A protective ventilation strategy was implemented on our intensive care unit in critical care patients who required mechanical ventilation for over 48 h, with and at risk for ARDS. A complete audit cycle was performed over 13 months to assess compliance with a safe ventilation protocol in intensive care. The ARDS network mechanical ventilation protocol was used as the standard for our protective ventilation strategy. This recommends ventilation with a tidal volume (V t) of 6 ml/kg of ideal body weight (IBW) and plateau airway pressure of ≤30 cm H2O. The initial audit failed to meet this standard with V t's of 9.5 ml/kg of IBW. Following the implementation of a ventilation strategy and an educational program, we demonstrate a significant improvement in practice with V t's of 6.6 ml/kg of IBW in the re-audit. This highlights the importance of simple interventions and continuous education in maintaining high standards of care.

  9. Prevention of respiratory complications of the surgical patient: actionable plan for continued process improvement.

    Science.gov (United States)

    Ruscic, Katarina J; Grabitz, Stephanie D; Rudolph, Maíra I; Eikermann, Matthias

    2017-06-01

    Postoperative respiratory complications (PRCs) increase hospitalization time, 30-day mortality and costs by up to $35 000. These outcomes measures have gained prominence as bundled payments have become more common. Results of recent quantitative effectiveness studies and clinical trials provide a framework that helps develop center-specific treatment guidelines, tailored to minimize the risk of PRCs. The implementation of those protocols should be guided by a local, respected, and visible facilitator who leads proper implementation while inviting center-specific input from surgeons, anesthesiologists, and other perioperative stakeholders. Preoperatively, patients should be risk-stratified for PRCs to individualize intraoperative choices and postoperative pathways. Laparoscopic compared with open surgery improves respiratory outcomes. High-risk patients should be treated by experienced providers based on locally developed bundle-interventions to optimize intraoperative treatment and ICU bed utilization. Intraoperatively, lung-protective ventilation (procedure-specific positive end-expiratory pressure utilization, and low driving pressure) and moderately restrictive fluid therapy should be used. To achieve surgical relaxation, high-dose neuromuscular blocking agents (and reversal agents) as well as high-dose opioids should be avoided; inhaled anesthetics improve surgical conditions while protecting the lungs. Patients should be extubated in reverse Trendelenburg position. Postoperatively, continuous positive airway pressure helps prevent airway collapse and protocolized, early mobilization improves cognitive and respiratory function.

  10. Modern approaches to physical rehabilitation of children, who often suffer from acute respiratory infections.

    Directory of Open Access Journals (Sweden)

    Khrystova T.E.

    2012-06-01

    Full Text Available There it is described a comprehensive program of physical rehabilitation, which aims at the prevention of acute respiratory diseases in children of primary school age. The research involved 106 children aged 6-9 years. Comprehensive program of physical rehabilitation included: aromafitotherapy and cryomassage of feet. The research proves that using of the mentioned methods leads to improving health, a significant decrease in throat hyperemia, cough and nasal discharge. It also helps to normalize the indices of breathing and physical development of children. More visible effect was observed while using the essential oils of sage and composition of essential oils (sage, lavender, mint. It is proved that the use of aromafitotherapy and cryomassage of feet helps to reduce the frequency of acute respiratory infections and exacerbations of chronic diseases of children upper respiratory organs at age of 6-12 months. It significantly reduces the number of days when children have to be absent at school because of illness.

  11. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC TREATMENT TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techn...

  12. A new laboratory-based surveillance system (Respiratory DataMart System) for influenza and other respiratory viruses in England: results and experience from 2009 to 2012.

    Science.gov (United States)

    Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R

    2014-01-23

    During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.

  13. The AgI/II family adhesin AspA is required for respiratory infection by Streptococcus pyogenes.

    Directory of Open Access Journals (Sweden)

    Linda Franklin

    Full Text Available Streptococcus pyogenes (GAS is a human pathogen that causes pharyngitis and invasive diseases such as toxic shock syndrome and sepsis. The upper respiratory tract is the primary reservoir from which GAS can infect new hosts and cause disease. The factors involved in colonisation are incompletely known however. Previous evidence in oral streptococci has shown that the AgI/II family proteins are involved. We hypothesized that the AspA member of this family might be involved in GAS colonization. We describe a novel mouse model of GAS colonization of the nasopharynx and lower respiratory tract to elucidate these interactions. We used two clinical M serotypes expressing AspA, and their aspA gene deletant isogenic mutants in experiments using adherence assays to respiratory epithelium, macrophage phagocytosis and neutrophil killing assays and in vivo models of respiratory tract colonisation and infection. We demonstrated the requirement for AspA in colonization of the respiratory tract. AspA mutants were cleared from the respiratory tract and were deficient in adherence to epithelial cells, and susceptible to phagocytosis. Expression of AspA in the surrogate host Lactococcus lactis protected bacteria from phagocytosis. Our results suggest that AspA has an essential role in respiratory infection, and may function as a novel anti-phagocytic factor.

  14. What You Can Do to Protect Children from Environmental Risks

    Science.gov (United States)

    Tips for protection from pesticides, chemical poisoning, lead poisoning, respiratory problems, carbon monoxide poisoning, contaminated fish, radon, too much sun, and mercury. Also how to promote healthier communities.

  15. Critical-thinking ability in respiratory care students and its correlation with age, educational background, and performance on national board examinations.

    Science.gov (United States)

    Wettstein, Richard B; Wilkins, Robert L; Gardner, Donna D; Restrepo, Ruben D

    2011-03-01

    Critical thinking is an important characteristic to develop in respiratory care students. We used the short-form Watson-Glaser Critical Thinking Appraisal instrument to measure critical-thinking ability in 55 senior respiratory care students in a baccalaureate respiratory care program. We calculated the Pearson correlation coefficient to assess the relationships between critical-thinking score, age, and student performance on the clinical-simulation component of the national respiratory care boards examination. We used chi-square analysis to assess the association between critical-thinking score and educational background. There was no significant relationship between critical-thinking score and age, or between critical-thinking score and student performance on the clinical-simulation component. There was a significant (P = .04) positive association between a strong science-course background and critical-thinking score, which might be useful in predicting a student's ability to perform in areas where critical thinking is of paramount importance, such as clinical competencies, and to guide candidate-selection for respiratory care programs.

  16. Influence of Low-Temperature Plasma Treatment on The Liquid Filtration Efficiency of Melt-Blown PP Nonwovens in The Conditions of Simulated Use of Respiratory Protective Equipment

    Directory of Open Access Journals (Sweden)

    Majchrzycka Katarzyna

    2017-06-01

    Full Text Available Filtering nonwovens produced with melt-blown technology are one of the most basic materials used in the construction of respiratory protective equipment (RPE against harmful aerosols, including bio- and nanoaerosols. The improvement of their filtering properties can be achieved by the development of quasi-permanent electric charge on the fibres. Usually corona discharge method is utilized for this purpose. In the presented study, it was assumed that the low-temperature plasma treatment could be applied as an alternative method for the manufacturing of conventional electret nonwovens for the RPE construction. Low temperature plasma treatment of polypropylene nonwovens was carried out with various process gases (argon, nitrogen, oxygen or air in a wide range of process parameters (gas flow velocity, time of treatment and power supplied to the reactor electrodes. After the modification, nonwovens were evaluated in terms of filtration efficiency of paraffin oil mist. The stability of the modification results was tested after 12 months of storage and after conditioning at elevated temperature and relative humidity conditions. Moreover, scanning electron microscopy and ATR-IR spectroscopy were used to assess changes in surface topography and chemical composition of the fibres. The modification of melt-blown nonwovens with nitrogen, oxygen and air plasma did not result in a satisfactory improvement of the filtration efficiency. In case of argon plasma treatment, up to 82% increase of filtration efficiency of paraffin oil mist was observed in relation to untreated samples. This effect was stable after 12 months of storage in normal conditions and after thermal conditioning in (70 ± 3°C for 24 h. The use of low-temperature plasma treatment was proven to be a promising improvement direction of filtering properties of nonwovens used for the protection of respiratory tract against harmful aerosols.

  17. Is Overall Mortality the Right Composite Endpoint in Clinical Trials of Acute Respiratory Distress Syndrome?

    Science.gov (United States)

    Villar, Jesús; Martínez, Domingo; Mosteiro, Fernando; Ambrós, Alfonso; Añón, José M; Ferrando, Carlos; Soler, Juan A; Montiel, Raquel; Vidal, Anxela; Conesa-Cayuela, Luís A; Blanco, Jesús; Arrojo, Regina; Solano, Rosario; Capilla, Lucía; Del Campo, Rafael; Civantos, Belén; Fernández, María Mar; Aldecoa, César; Parra, Laura; Gutiérrez, Andrea; Martínez-Jiménez, Chanel; González-Martín, Jesús M; Fernández, Rosa L; Kacmarek, Robert M

    2018-06-01

    Overall mortality in patients with acute respiratory distress syndrome is a composite endpoint because it includes death from multiple causes. In most acute respiratory distress syndrome trials, it is unknown whether reported deaths are due to acute respiratory distress syndrome or the underlying disease, unrelated to the specific intervention tested. We investigated the causes of death after contracting acute respiratory distress syndrome in a large cohort. A secondary analysis from three prospective, multicenter, observational studies. A network of multidisciplinary ICUs. We studied 778 patients with moderate-to-severe acute respiratory distress syndrome treated with lung-protective ventilation. None. We examined death in the ICU from individual causes. Overall ICU mortality was 38.8% (95% CI, 35.4-42.3). Causes of acute respiratory distress syndrome modified the risk of death. Twenty-three percent of deaths occurred from refractory hypoxemia due to nonresolving acute respiratory distress syndrome. Most patients died from causes unrelated to acute respiratory distress syndrome: 48.7% of nonsurvivors died from multisystem organ failure, and cancer or brain injury was involved in 37.1% of deaths. When quantifying the true burden of acute respiratory distress syndrome outcome, we identified 506 patients (65.0%) with one or more exclusion criteria for enrollment into current interventional trials. Overall ICU mortality of the "trial cohort" (21.3%) was markedly lower than the parent cohort (relative risk, 0.55; 95% CI, 0.43-0.70; p respiratory distress syndrome patients are not directly related to lung damage but to extrapulmonary multisystem organ failure. It would be challenging to prove that specific lung-directed therapies have an effect on overall survival.

  18. Impact of NOx Emission Reduction Policy on Hospitalizations for Respiratory Disease in New York State

    Science.gov (United States)

    To date, only a limited number of studies have examined the impact of ambient pollutant policy on respiratory morbidities. This accountability study examined the effect of a regional pollution control policy, namely, the US Environmental Protection Agency’s (EPA) nitrogen oxides ...

  19. Weldon Spring Site Remedial Action Project: Report from the DOE voluntary protection program onsite review, November 17--21, 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-28

    This report summarizes the Department of Energy Voluntary Protection Program (DOE-VPP) Review Team`s findings from the five-day onsite evaluation of the Weldon Spring Site Remedial Action Project (WSSRAP), conducted November 17--21, 1997. The site was evaluated against the program requirements contained in ``US Department of Energy Voluntary Protection Program, Part 1: Program Elements`` to determine its success in implementing the five tenets of DOE-VPP. DOE-VPP consists of three programs, with names and functions similar to those in OSHA`s VPP. These programs are STAR, MERIT, and DEMONSTRATION. The STAR program is the core of DOE-VPP. The program is aimed at truly outstanding protectors of employee safety and health. The MERIT program is a steppingstone for contractors and subcontractors that have good safety and health programs but need time and DOE guidance to achieve STAR status. The DEMONSTRATION program is rarely used; it allows DOE to recognize achievements in unusual situations about which DOE needs to learn more before determining approval requirements for the STAR status.

  20. Weldon Spring Site Remedial Action Project: Report from the DOE voluntary protection program onsite review, November 17-21, 1997

    International Nuclear Information System (INIS)

    1998-01-01

    This report summarizes the Department of Energy Voluntary Protection Program (DOE-VPP) Review Team's findings from the five-day onsite evaluation of the Weldon Spring Site Remedial Action Project (WSSRAP), conducted November 17--21, 1997. The site was evaluated against the program requirements contained in ''US Department of Energy Voluntary Protection Program, Part 1: Program Elements'' to determine its success in implementing the five tenets of DOE-VPP. DOE-VPP consists of three programs, with names and functions similar to those in OSHA's VPP. These programs are STAR, MERIT, and DEMONSTRATION. The STAR program is the core of DOE-VPP. The program is aimed at truly outstanding protectors of employee safety and health. The MERIT program is a steppingstone for contractors and subcontractors that have good safety and health programs but need time and DOE guidance to achieve STAR status. The DEMONSTRATION program is rarely used; it allows DOE to recognize achievements in unusual situations about which DOE needs to learn more before determining approval requirements for the STAR status

  1. Cow's milk and immune function in the respiratory tract

    OpenAIRE

    Perdijk, Olaf; Splunter, van, Marloes; Savelkoul, Huub F.J.; Brugman, Sylvia; Neerven, van, Joost

    2018-01-01

    During the last decades, the world has witnessed a dramatic increase in allergy prevalence. Epidemiological evidence shows that growing up on a farm is a protective factor, which is partly explained by the consumption of raw cow's milk. Indeed, recent studies show inverse associations between raw cow's milk consumption in early life and asthma, hay fever, and rhinitis. A similar association of raw cow's milk consumption with respiratory tract infections is recently found. In line with these f...

  2. Comparison of old and new ICRP models for respiratory tract dosimetry

    International Nuclear Information System (INIS)

    Boecker, B.B.

    1993-01-01

    This paper examines the historical development and application of respiratory tract dosimetry models by the International Commission for Radiological Protection, ICRP, for health protection from inhaled radioactive aerosols. Three different models are discussed, those that were included in ICRP recommendations published in 1960 and 1979, and the new ICRP Publication 66. Basic features of these models are compared and contrasted. These features include model structure, sites and frequencies of particle deposition, processes and rates of clearance of the deposited material from the respiratory tract, and consideration of the parameters involved in these processes and how various factors can influence these parameters. All three models lead to the calculation of absorbed radiation doses with differing degrees of regional and local specificity. These calculations are achieved using different tools ranging from quick hand calculations to sophisticated computerized modeling approaches. A side-by-side review of these models indicates several important trends in respiratory tract dosimetry models, the most obvious of which is the increased complexity of each new model over the past 30+ years. These increases reflect both the increasing size of the knowledge base derived from studies in laboratory animals and in human subjects and the need for models more broadly applicable for both occupational and environmental exposures. It is likely that future research will be directed to those key aspects of the new model having the largest uncertainties. The detailed design of the new model and its associated software provide excellent means of identifying useful research areas and using the resulting new information in organized and productive ways

  3. Increased respiratory symptoms in COPD patients living in the vicinity of livestock farms.

    Science.gov (United States)

    Borlée, Floor; Yzermans, C Joris; van Dijk, Christel E; Heederik, Dick; Smit, Lidwien A M

    2015-12-01

    Several studies have investigated the effect of livestock farm emissions on the respiratory health of local residents, but results are inconsistent. This study aims to explore associations between the presence of livestock farms and respiratory health in an area of high-density livestock farming in the Netherlands. We focused especially on associations between farm exposures and respiratory symptoms within subgroups of potentially susceptible patients with a pre-existing lung disease.In total, 14 875 adults (response rate 53.4%) completed a questionnaire concerning respiratory health, smoking habits and personal characteristics. Different indicators of livestock farm exposures relative to the home address were computed using a geographic information system.Prevalence of chronic obstructive pulmonary disease (COPD) and asthma was lower among residents living within 100 m of a farm (OR 0.47, 95% CI 0.24-0.91 and OR 0.65, 95% CI 0.45-0.93, respectively). However, >11 farms in 1000 m compared to fewer than four farms in 1000 m (fourth quartile versus first quartile) was associated with wheezing among COPD patients (OR 1.71, 95% CI 1.01-2.89). Using general practitioners' electronic medical records, we demonstrated that selection bias did not affect the observed associations.Our data suggest a protective effect of livestock farm emissions on the respiratory health of residents. Nonetheless, COPD patients living near livestock farms reported more respiratory symptoms, suggesting an increased risk of exacerbations. Copyright ©ERS 2015.

  4. Pollution and respiratory disease: can diet or supplements help? A review.

    Science.gov (United States)

    Whyand, T; Hurst, J R; Beckles, M; Caplin, M E

    2018-05-02

    Pollution is known to cause and exacerbate a number of chronic respiratory diseases. The World Health Organisation has placed air pollution as the world's largest environmental health risk factor. There has been recent publicity about the role for diet and anti-oxidants in mitigating the effects of pollution, and this review assesses the evidence for alterations in diet, including vitamin supplementation in abrogating the effects of pollution on asthma and other chronic respiratory diseases. We found evidence to suggest that carotenoids, vitamin D and vitamin E help protect against pollution damage which can trigger asthma, COPD and lung cancer initiation. Vitamin C, curcumin, choline and omega-3 fatty acids may also play a role. The Mediterranean diet appears to be of benefit in patients with airways disease and there appears to be a beneficial effect in smokers however there is no direct evidence regarding protecting against air pollution. More studies investigating the effects of nutrition on rapidly rising air pollution are urgently required. However it is very difficult to design such studies due to the confounding factors of diet, obesity, co-morbid illness, medication and environmental exposure.

  5. Managing respiratory problems in athletes.

    Science.gov (United States)

    Hull, James H; Ansley, Les; Robson-Ansley, Paula; Parsons, Jonathan P

    2012-08-01

    Respiratory problems are common in athletes of all abilities and can significantly impact upon their health and performance. In this article, we provide an overview of respiratory physiology in athletes. We also discuss the assessment and management of common clinical respiratory conditions as they pertain to athletes, including airways disease, respiratory tract infection and pneumothorax. We focus on providing a pragmatic approach and highlight important caveats for the physician treating respiratory conditions in this highly specific population.

  6. Live Attenuated Tularemia Vaccines for Protection Against Respiratory Challenge With Virulent F. tularensis subsp. tularensis

    Science.gov (United States)

    Jia, Qingmei; Horwitz, Marcus A.

    2018-01-01

    Francisella tularensis is the causative agent of tularemia and a Tier I bioterrorism agent. In the 1900s, several vaccines were developed against tularemia including the killed “Foshay” vaccine, subunit vaccines comprising F. tularensis protein(s) or lipoproteins(s) in an adjuvant formulation, and the F. tularensis Live Vaccine Strain (LVS); none were licensed in the U.S.A. or European Union. The LVS vaccine retains toxicity in humans and animals—especially mice—but has demonstrated efficacy in humans, and thus serves as the current gold standard for vaccine efficacy studies. The U.S.A. 2001 anthrax bioterrorism attack spawned renewed interest in vaccines against potential biowarfare agents including F. tularensis. Since live attenuated—but not killed or subunit—vaccines have shown promising efficacy and since vaccine efficacy against respiratory challenge with less virulent subspecies holarctica or F. novicida, or against non-respiratory challenge with virulent subsp. tularensis (Type A) does not reliably predict vaccine efficacy against respiratory challenge with virulent subsp. tularensis, the route of transmission and species of greatest concern in a bioterrorist attack, in this review, we focus on live attenuated tularemia vaccine candidates tested against respiratory challenge with virulent Type A strains, including homologous vaccines derived from mutants of subsp. holarctica, F. novicida, and subsp. tularensis, and heterologous vaccines developed using viral or bacterial vectors to express F. tularensis immunoprotective antigens. We compare the virulence and efficacy of these vaccine candidates with that of LVS and discuss factors that can significantly impact the development and evaluation of live attenuated tularemia vaccines. Several vaccines meet what we would consider the minimum criteria for vaccines to go forward into clinical development—safety greater than LVS and efficacy at least as great as LVS, and of these, several meet the

  7. Does respiratory muscle training increase physical performance?

    Science.gov (United States)

    Sperlich, Billy; Fricke, Hannes; de Marées, Markus; Linville, John W; Mester, Joachim

    2009-09-01

    Special force units and military personnel undergo demanding physical exercise and might benefit from high-intensity respiratory muscle training (RMT) by increasing their endurance performance. This study examined the effects of a 6-week high-intensity RMT on running performance and oxygen uptake (VO2max) in a group of German Special Force Squad members. 17 participants were randomly assigned to a training or control group. Baseline and post-testing included a ramp test, as well as an incremental test on a treadmill, performed to physical exhaustion. VO2, respiratory exchange ratio, and heart rate were measured breath by breath. Furthermore, maximum running speed (V(max)), 4 mmol x 1(-1) lactate threshold (V4) and perception of respiratory effort were determined. During pulmonary testing, sustained maximum inspiratory and expiratory pressure (PI(max) and PE(max)) were obtained. RMT was performed daily at approximately 90% PI(max) for 6 weeks with 2 x 30 breath cycles using an Ultrabreathe lung trainer. No statistical differences were detected between the groups for any parameter after RMT. High-intensity RMT did not show any benefits on VO2max and endurance performance and are unlikely to be of benefit to military or paramilitary training programs for an increase in endurance performance.

  8. Respiratory Syncytial Virus

    Science.gov (United States)

    ... with facebook share with twitter share with linkedin Respiratory Syncytial Virus (RSV) Credit: CDC This is the ... the United States. Why Is the Study of Respiratory Syncytial Virus (RSV) a Priority for NIAID? In ...

  9. Deposition of inhaled particles in the respiratory tract as a function of age at exposure

    International Nuclear Information System (INIS)

    Thomas, R.G.; Healy, J.W.

    1985-01-01

    A respiratory tract deposition model was developed that would accommodate age 1 month to adulthood as an initial step in calculating radiation dose following inhalation during environmental exposures. The approach to changing respiratory tract and physiological parameters to be applicable to children was to derive an analytical function describing the ratio of the child value to the value for a reference adult with the desired characteristics. A computer program was written to carry out the tracing of airflow through the respiratory tract and deposition in each of the sections for monodispersed particles of known density and diameter. 7 references

  10. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity

    Directory of Open Access Journals (Sweden)

    Katarzyna Majchrzycka

    2016-01-01

    Full Text Available Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs. Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%–92% and temperature increased to 29–30 °C. S. aureus survived the best on filter materials with 40%–200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48–72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  11. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity.

    Science.gov (United States)

    Majchrzycka, Katarzyna; Okrasa, Małgorzata; Skóra, Justyna; Gutarowska, Beata

    2016-01-04

    Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs). Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%-92% and temperature increased to 29-30 °C. S. aureus survived the best on filter materials with 40%-200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48-72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  12. National Renewable Energy Laboratory program on lightning risk and wind turbine generator protection

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E. [National Renewable Energy Lab., Golden, CO (United States); McNiff, B. [McNiff Light Industry, Blue Hill, ME (United States)

    1997-12-31

    In the early development of wind turbine generators (WTG) in the United States, wind farms were primarily located in California where lightning activity is the lowest in the United States. As such, lightning protection for wind turbines was not considered to be a major issue for designers or wind farm operators. However, wind turbine installations are expanding into the Midwest, Southwest and other regions of the United States where lightning activity is significantly more intense and lightning damage to wind turbines is more common. There is a growing need, therefore, to better understand lightning activity on wind farms and to improve wind turbine lightning protection systems. In support of the U.S. Department of Energy/Electric Power Research Institute (DOE/EPRI) Utility Wind Turbine Verification Program (TVP), the National Renewable Energy Laboratory (NREL) has recently begun to take steps to determine the extent of damage due to lightning and the effectiveness of various lightning protection techniques for wind power plants. Working through the TVP program, NREL will also perform outreach and education to (1) help manufacturers to provide equipment that is adequately designed to survive lightning, (2) make sure that operators are aware of effective safety procedures, and (3) help site designers and wind farm developers take the risk of lightning into account as effectively as possible.

  13. Iterative integral parameter identification of a respiratory mechanics model.

    Science.gov (United States)

    Schranz, Christoph; Docherty, Paul D; Chiew, Yeong Shiong; Möller, Knut; Chase, J Geoffrey

    2012-07-18

    Patient-specific respiratory mechanics models can support the evaluation of optimal lung protective ventilator settings during ventilation therapy. Clinical application requires that the individual's model parameter values must be identified with information available at the bedside. Multiple linear regression or gradient-based parameter identification methods are highly sensitive to noise and initial parameter estimates. Thus, they are difficult to apply at the bedside to support therapeutic decisions. An iterative integral parameter identification method is applied to a second order respiratory mechanics model. The method is compared to the commonly used regression methods and error-mapping approaches using simulated and clinical data. The clinical potential of the method was evaluated on data from 13 Acute Respiratory Distress Syndrome (ARDS) patients. The iterative integral method converged to error minima 350 times faster than the Simplex Search Method using simulation data sets and 50 times faster using clinical data sets. Established regression methods reported erroneous results due to sensitivity to noise. In contrast, the iterative integral method was effective independent of initial parameter estimations, and converged successfully in each case tested. These investigations reveal that the iterative integral method is beneficial with respect to computing time, operator independence and robustness, and thus applicable at the bedside for this clinical application.

  14. Respiratory viral infections in infancy and school age respiratory outcomes and healthcare costs.

    Science.gov (United States)

    MacBean, Victoria; Drysdale, Simon B; Yarzi, Muska N; Peacock, Janet L; Rafferty, Gerrard F; Greenough, Anne

    2018-03-01

    To determine the impact of viral lower respiratory tract infections (LRTIs) in infancy including rhinovirus (RV) and infancy respiratory syncytial virus (RSV), on school age pulmonary function and healthcare utilization in prematurely born children. School age respiratory outcomes would be worse and healthcare utilization greater in children who had viral LRTIs in infancy. Prospective study. A cohort of prematurely born children who had symptomatic LRTIs during infancy documented, was recalled. Pulmonary function was assessed at 5 to 7 years of age and health related costs of care from aged one to follow-up determined. Fifty-one children, median gestational age 33 +6 weeks, were assessed at a median (IQR) age 7.03 (6.37-7.26) years. Twenty-one children had no LRTI, 14 RV LRTI, 10 RSV LRTI, and 6 another viral LRTI (other LRTI). Compared to the no LRTI group, the RV group had a lower FEV 1 (P = 0.033) and the other LRTI group a lower FVC (P = 0.006). Non-respiratory medication costs were higher in the RV (P = 0.018) and RSV (P = 0.013) groups. Overall respiratory healthcare costs in the RV (£153/year) and RSV (£27/year) groups did not differ significantly from the no LRTI group (£56/year); the other LRTI group (£431/year) had higher respiratory healthcare costs (P = 0.042). In moderately prematurely born children, RV and RSV LRTIs in infancy were not associated with higher respiratory healthcare costs after infancy. Children who experienced LRTIs caused by other respiratory viruses (including RV) had higher respiratory healthcare costs and greater pulmonary function impairment. © 2018 Wiley Periodicals, Inc.

  15. Respiratory viruses in children hospitalized for acute lower respiratory tract infection in Ghana.

    Science.gov (United States)

    Kwofie, Theophilus B; Anane, Yaw A; Nkrumah, Bernard; Annan, Augustina; Nguah, Samuel B; Owusu, Michael

    2012-04-10

    Acute respiratory tract infections are one of the major causes of morbidity and mortality among young children in developing countries. Information on the viral aetiology of acute respiratory infections in developing countries is very limited. The study was done to identify viruses associated with acute lower respiratory tract infection among children less than 5 years. Nasopharyngeal samples and blood cultures were collected from children less than 5 years who have been hospitalized for acute lower respiratory tract infection. Viruses and bacteria were identified using Reverse Transcriptase Real-Time Polymerase Chain Reaction and conventional biochemical techniques. Out of 128 patients recruited, 33(25.88%%, 95%CI: 18.5% to 34.2%) were positive for one or more viruses. Respiratory Syncytial Virus (RSV) was detected in 18(14.1%, 95%CI: 8.5% to 21.3%) patients followed by Adenoviruses (AdV) in 13(10.2%, 95%CI: 5.5% to 16.7%), Parainfluenza (PIV type: 1, 2, 3) in 4(3.1%, 95%CI: 0.9% to 7.8%) and influenza B viruses in 1(0.8%, 95%CI: 0.0 to 4.3). Concomitant viral and bacterial co-infection occurred in two patients. There were no detectable significant differences in the clinical signs, symptoms and severity for the various pathogens isolated. A total of 61.1% (22/36) of positive viruses were detected during the rainy season and Respiratory Syncytial Virus was the most predominant. The study has demonstrated an important burden of respiratory viruses as major causes of childhood acute respiratory infection in a tertiary health institution in Ghana. The data addresses a need for more studies on viral associated respiratory tract infection.

  16. Modern features of infants’ feeding and its impact on respiratory diseases

    Directory of Open Access Journals (Sweden)

    Duka K.D.

    2015-03-01

    Full Text Available The article discusses the problem of infants’ feeding connected with the incidence of respiratory diseases. Rationality and duration of breast feeding does not cause doubts. But unfortunately today, only 60-80% of children under the age of 6 months are exclusively breastfed. Naturally, this causes impact on disease incidence of such children. Formation of bronchopulmonary pathology is of particular interest. The basis of modern research is the concept of programmed impact of nutrition in early childhood on health in lateryears. We have determined the dependence of respiratory diseases incidence in children of early age on duration of exclusively breast feeding. Not only frequent respiratory diseases, but formation of bronchitis, pneumonia or other complications of their course is of importance. The study included questioning of mothers and children under 7 years of age, clinical, radiological and laboratory investigations in the hospital in case of respiratory disease. All studies were conducted in accordance with the characteristics of diet quality of the child in the first year of life with the following biostatistical processing. 601 children aged from 3 months to 7 years were examined. It was found that the duration of breast feeding in the region is 89% only to the age of 6-months, and up to 1 year the percentage of breastfed children reduces to 38%. This affected the resistance of children to respiratory infections, especially in the first year of life. Children exclusively breastfed up to 1 year suffer from respiratory diseases 1-2 times per year. In children over one year of age breast feeding does not affect the frequency of respiratory pathology. Increase of respiratory diseases frequency in children aged 3-5 years is due to attending preschool institutions and increasing contacts between children, which significantly reduces their resistance.

  17. Does Viral Co-Infection Influence the Severity of Acute Respiratory Infection in Children?

    Science.gov (United States)

    Cebey-López, Miriam; Herberg, Jethro; Pardo-Seco, Jacobo; Gómez-Carballa, Alberto; Martinón-Torres, Nazareth; Salas, Antonio; Martinón-Sánchez, José María; Justicia, Antonio; Rivero-Calle, Irene; Sumner, Edward; Fink, Colin; Martinón-Torres, Federico

    2016-01-01

    Multiple viruses are often detected in children with respiratory infection but the significance of co-infection in pathogenesis, severity and outcome is unclear. To correlate the presence of viral co-infection with clinical phenotype in children admitted with acute respiratory infections (ARI). We collected detailed clinical information on severity for children admitted with ARI as part of a Spanish prospective multicenter study (GENDRES network) between 2011-2013. A nested polymerase chain reaction (PCR) approach was used to detect respiratory viruses in respiratory secretions. Findings were compared to an independent cohort collected in the UK. 204 children were recruited in the main cohort and 97 in the replication cohort. The number of detected viruses did not correlate with any markers of severity. However, bacterial superinfection was associated with increased severity (OR: 4.356; P-value = 0.005), PICU admission (OR: 3.342; P-value = 0.006), higher clinical score (1.988; P-value = 0.002) respiratory support requirement (OR: 7.484; P-value respiratory distress (OR: 2.917; P-value = 0.035), PICU admission (OR: 0.301; P-value = 0.011), lower clinical score (-1.499; P-value = 0.021) respiratory support requirement (OR: 0.324; P-value = 0.016) and oxygen necessity (OR: 0.328; P-value = 0.001). All these findings were replicated in the UK cohort. The presence of more than one virus in hospitalized children with ARI is very frequent but it does not seem to have a major clinical impact in terms of severity. However bacterial superinfection increases the severity of the disease course. On the contrary, pneumococcal vaccination plays a protective role.

  18. Respiratory alkalosis in children with febrile seizures.

    Science.gov (United States)

    Schuchmann, Sebastian; Hauck, Sarah; Henning, Stephan; Grüters-Kieslich, Annette; Vanhatalo, Sampsa; Schmitz, Dietmar; Kaila, Kai

    2011-11-01

    Febrile seizures (FS) are the most common type of convulsive events in children. FS are suggested to result from a combination of genetic and environmental factors. However, the pathophysiologic mechanisms underlying FS remain unclear. Using an animal model of experimental FS, it was demonstrated that hyperthermia causes respiratory alkalosis with consequent brain alkalosis and seizures. Here we examine the acid-base status of children who were admitted to the hospital for FS. Children who were admitted because of gastroenteritis (GE), a condition known to promote acidosis, were examined to investigate a possible protective effect of acidosis against FS. We enrolled 433 age-matched children with similar levels of fever from two groups presented to the emergency department. One group was admitted for FS (n = 213) and the other for GE (n = 220). In the FS group, the etiology of fever was respiratory tract infection (74.2%), otitis media (7%), GE (7%), tonsillitis (4.2%), scarlet fever (2.3%) chickenpox (1.4%), urinary tract infection (1.4%), postvaccination reaction (0.9%), or unidentified (1.4%). In all patients, capillary pH and blood Pco(2) were measured immediately on admission to the hospital. Respiratory alkalosis was found in children with FS (pH 7.46 ± 0.04, [mean ± standard deviation] Pco(2) 29.5 ± 5.5 mmHg), whereas a metabolic acidosis was seen in all children admitted for GE (pH 7.31 ± 0.03, Pco(2) 37.7 ± 4.3 mmHg; p respiratory alkalosis, irrespective of the severity of the underlying infection as indicated by the level of fever. The lack of FS in GE patients is attributable to low pH, which also explains the fact that children with a susceptibility to FS do not have seizures when they have GE-induced fever that is associated with acidosis. The present demonstration of a close link between FS and respiratory alkalosis may pave the way for further clinical studies and attempts to design novel therapies for the treatment of FS by controlling the

  19. Measuring the impact of air pollution on respiratory infection risk in China

    International Nuclear Information System (INIS)

    Tang, Sanyi; Yan, Qinling; Shi, Wei; Wang, Xia; Sun, Xiaodan; Yu, Pengbo; Wu, Jianhong; Xiao, Yanni

    2018-01-01

    China is now experiencing major public health challenges caused by air pollution. Few studies have quantified the dynamics of air pollution and its impact on the risk of respiratory infection. We conducted an integrated data analysis to quantify the association among air quality index (AQI), meteorological variables and respiratory infection risk in Shaanxi province of China in the period of November 15th, 2010 to November 14th, 2016. Our analysis illustrated a statistically significantly positive correlation between the number of influenza-like illness (ILI) cases and AQI, and the respiratory infection risk has increased progressively with increased AQI with a time lag of 0–3 days. We also developed mathematical models for the AQI trend and respiratory infection dynamics, incorporating AQI-dependent incidence and AQI-based behaviour change interventions. Our combined data and modelling analysis estimated the basic reproduction number for the respiratory infection during the studying period to be 2.4076, higher than the basic reproduction number of the 2009 pandemic influenza in the same province. Our modelling-based simulations concluded that, in terms of respiratory infection risk reduction, the persistent control of emission in the China's blue-sky programme is much more effective than substantial social-economic interventions implemented only during the smog days. - Highlights: • Quantify the dynamics of air pollution, evaluate impact on respiratory infection. • Present a novel methodology through integrating statistic and dynamic models. • The respiratory infection risk has increased with increased air quality index. • Persistent control of emission in China's blue-sky program is much more effective. - This study presented a novel methodology to quantify the dynamics of air pollution and evaluate its impact of on the risk of respiratory infection, and hence to suggest interventions for China's blue-sky programme.

  20. A prime-boost vaccination strategy using attenuated Salmonella typhimurium and a replication-deficient recombinant adenovirus vector elicits protective immunity against human respiratory syncytial virus.

    Science.gov (United States)

    Fu, Yuan-Hui; He, Jin-Sheng; Wang, Xiao-Bo; Zheng, Xian-Xian; Wu, Qiang; Xie, Can; Zhang, Mei; Wei, Wei; Tang, Qian; Song, Jing-Dong; Qu, Jian-Guo; Hong, Tao

    2010-04-23

    Human respiratory syncytial virus (RSV), for which no clinically approved vaccine is available yet, is globally a serious pediatric pathogen of the lower respiratory tract. Several approaches have been used to develop vaccines against RSV, but none of these have been approved for use in humans. An efficient vaccine-enhancing strategy for RSV is still urgently needed. We found previously that oral SL7207/pcDNA3.1/F and intranasal FGAd/F were able to induce an effective protective immune response against RSV. The heterologous prime-boost immunization regime has been reported recently to be an efficient vaccine-enhancing strategy. Therefore, we investigated the ability of an oral SL7207/pcDNA3.1/F prime and intranasal (i.n.) FGAd/F boost regimen to generate immune responses to RSV. The SL7207/pcDNA3.1/F prime-FGAd/F boost regimen generated stronger RSV-specific humoral and mucosal immune responses in BALB/c mice than the oral SL7207/pcDNA3.1/F regimen alone, and stronger specific cellular immune responses than the i.n. FGAd/F regimen alone. Histopathological analysis showed an increased efficacy against RSV challenge by the heterologous prime-boost regimen. These results suggest that such a heterologous prime-boost strategy can enhance the efficacy of either the SL7207 or the FGAd vector regimen in generating immune responses in BALB/c mice. 2010 Elsevier Inc. All rights reserved.

  1. [Respiratory symptoms and atmospheric pollution and respiratory symptoms in the general population].

    Science.gov (United States)

    Simon, I; Charpin, D

    2010-06-01

    Epidemiological studies on air pollution have mainly been interested in the effects of short- or long-term exposure on patients suffering from respiratory illnesses. Fewer studies have addressed the acute effects of air pollution on respiratory symptoms in the general population. We conducted a review of the literature over the last 16years that has addressed the impact of atmospheric pollution on respiratory symptoms in the general population to estimate the magnitude of effect. The majority of studies demonstrated a significant association between exposure to air pollutants and the occurrence of respiratory symptoms, without any threshold. Although a link between atmospheric pollution and respiratory symptoms has been demonstrated, knowledge of the effects of specific air pollutants and the effect of pollution on particular vulnerable groups (infants, young children, the elderly) is still limited. There is a need for further studies in this area. Copyright 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  2. Feedback and education improve physician compliance in use of lung-protective mechanical ventilation

    NARCIS (Netherlands)

    Wolthuis, Esther K.; Korevaar, Johanna C.; Spronk, Peter; Kuiper, Michael A.; Dzoljic, Misa; Vroom, Margreeth B.; Schultz, Marcus J.

    2005-01-01

    Objective: Use of lung-protective mechanical ventilation (MV) by applying lower tidal volumes is recommended in patients suffering from acute lung injury (ALI) or acute respiratory distress syndrome (ARDS). Recent data suggest that lung-protective MV may benefit non-ALI/ARDS patients as well. This

  3. Respiratory viruses in children hospitalized for acute lower respiratory tract infection in Ghana

    Directory of Open Access Journals (Sweden)

    Kwofie Theophilus B

    2012-04-01

    Full Text Available Abstract Background Acute respiratory tract infections are one of the major causes of morbidity and mortality among young children in developing countries. Information on the viral aetiology of acute respiratory infections in developing countries is very limited. The study was done to identify viruses associated with acute lower respiratory tract infection among children less than 5 years. Method Nasopharyngeal samples and blood cultures were collected from children less than 5 years who have been hospitalized for acute lower respiratory tract infection. Viruses and bacteria were identified using Reverse Transcriptase Real-Time Polymerase Chain Reaction and conventional biochemical techniques. Results Out of 128 patients recruited, 33(25.88%%, 95%CI: 18.5% to 34.2% were positive for one or more viruses. Respiratory Syncytial Virus (RSV was detected in 18(14.1%, 95%CI: 8.5% to 21.3% patients followed by Adenoviruses (AdV in 13(10.2%, 95%CI: 5.5% to 16.7%, Parainfluenza (PIV type: 1, 2, 3 in 4(3.1%, 95%CI: 0.9% to 7.8% and influenza B viruses in 1(0.8%, 95%CI: 0.0 to 4.3. Concomitant viral and bacterial co-infection occurred in two patients. There were no detectable significant differences in the clinical signs, symptoms and severity for the various pathogens isolated. A total of 61.1% (22/36 of positive viruses were detected during the rainy season and Respiratory Syncytial Virus was the most predominant. Conclusion The study has demonstrated an important burden of respiratory viruses as major causes of childhood acute respiratory infection in a tertiary health institution in Ghana. The data addresses a need for more studies on viral associated respiratory tract infection.

  4. Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yeong Cheol; Kim, Sun Myung; Do, Gyeong Min; Park, Geun Yong; Kim, Gun Oh; Kim, Young Bum [Dept. of Radiation Oncology, Guro Hospital, Korea Univeristy, Seoul (Korea, Republic of)

    2012-09-15

    The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded after the therapy. The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory

  5. Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy

    International Nuclear Information System (INIS)

    Lee, Yeong Cheol; Kim, Sun Myung; Do, Gyeong Min; Park, Geun Yong; Kim, Gun Oh; Kim, Young Bum

    2012-01-01

    The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded after the therapy. The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance

  6. Notification: Review of the U.S. Environmental Protection Agency's Purchase Card and Convenience Check Program

    Science.gov (United States)

    Project #OA-FY13-0116, December 20, 2012. The U.S. Environmental Protection Agency, Office of Inspector General, plans to begin preliminary research for an audit of the agency’s purchase card and convenience check programs.

  7. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  8. Ocular Tropism of Respiratory Viruses

    Science.gov (United States)

    Rota, Paul A.; Tumpey, Terrence M.

    2013-01-01

    SUMMARY Respiratory viruses (including adenovirus, influenza virus, respiratory syncytial virus, coronavirus, and rhinovirus) cause a broad spectrum of disease in humans, ranging from mild influenza-like symptoms to acute respiratory failure. While species D adenoviruses and subtype H7 influenza viruses are known to possess an ocular tropism, documented human ocular disease has been reported following infection with all principal respiratory viruses. In this review, we describe the anatomical proximity and cellular receptor distribution between ocular and respiratory tissues. All major respiratory viruses and their association with human ocular disease are discussed. Research utilizing in vitro and in vivo models to study the ability of respiratory viruses to use the eye as a portal of entry as well as a primary site of virus replication is highlighted. Identification of shared receptor-binding preferences, host responses, and laboratory modeling protocols among these viruses provides a needed bridge between clinical and laboratory studies of virus tropism. PMID:23471620

  9. Three example applications of optimization techniques to Department of Energy contractor radiation protection programs

    International Nuclear Information System (INIS)

    Merwin, S.E.; Martin, J.B.; Tawil, J.J.; Selby, J.M.

    1989-01-01

    Six numerical examples of optimization of radiation protection are provided in the appendices of International Commission on Radiological Protection (ICRP) Publication No. 37 (1983). In each case, the calculations were based on well-defined parameters and assumptions. In this paper, we examined three different numerical examples that were based on empirical data and less-certain assumptions. In the first example, the optimum sampling frequency for a typical 3H bioassay program was found to be once every 2 mo. However, this result depended on assumed values for several variables that were difficult to evaluate. The second example showed that the optimum frequency for recalibrating a group of cutie pie (CP) ionization chamber survey instruments was once every 85 d. This result depended largely on the assumption that an improperly operating CP instrument could lead to a serious overexposure. In the third example, one continuous air monitor (CAM) was determined to be the optimum number in a workplace at a Department of Energy (DOE) Pu facility. The optimum location of the CAM was determined from past glove-box release studies. These examples demonstrated that cost-benefit analysis of individual elements of radiation protection programs can be useful even if limited data are available

  10. 78 FR 6350 - The Standard on 4,4′-Methylenedianiline for General Industry; Extension of the Office of...

    Science.gov (United States)

    2013-01-30

    ... exposure to MDA, including cancer, liver and skin disease. The major paperwork requirements specify that... a respiratory protection program in accordance with 29 CFR 1910.134 (OSHA's Respiratory Protection... hours. This adjustment is the result of increasing the job hire rate from 10% to 25.6%, resulting in an...

  11. Phytotherapy of Acute Respiratory Viral Diseases

    Directory of Open Access Journals (Sweden)

    I.B. Ershova

    2016-11-01

    Full Text Available Nowadays phytotherapy is increasingly being implemented into medical practice, especially for the prevention and treatment of many diseases. Acute respiratory viral infections are most common in childhood and in adults. Acute rhinitis, pharyngitis, tonsillitis, sinusitis, nasopharyngitis and acute laryngitis refer to diseases of the upper respiratory tract. The main reason for respiratory diseases in recurrent respiratory infection child is disorders of mucociliary and immune protection. The therapeutic value of medicinal plants is determined by their biologically active substances. The method of application of phytotherpy is an integral part of traditional medicine. Herbal medicine can be used at home and does not require special equipment. The main indications for the herbal medicine use in pediatrics are the initial stage of the disease as a primary method of treatment due to mild and low toxicity; as a supporting treatment for enhancing the protective forces of the child’s body during the disease deterioration. During the recovery period herbal medicine again occupies a leading position, especially in case of chronic diseases because it can be used for a long time and is well combined with synthetic drugs. The terms of appointment of herbs for children: prescription of medicinal plants for children must be individual according to indications, taking into account the child’s age; it is recommended to take into account the form and nature of the course of the main disease and comorbidities as well; at the initial stage of the treatment it is better to use some medicinal plants or species consisting of 2–3 plants and in the future a more complex composition; therapy with medicinal plants requires a long period to be used use, especially in chronic diseases; in the treatment of chronic diseases a good effect preventive courses of herbal medicine was revealed, which are appointed during seasonal exacerbations; in case of intolerance

  12. Systemic Foot-and-Mouth Disease Vaccination in Cattle Promotes Specific Antibody-Secreting Cells at the Respiratory Tract and Triggers Local Anamnestic Responses upon Aerosol Infection.

    Science.gov (United States)

    Pega, J; Di Giacomo, S; Bucafusco, D; Schammas, J M; Malacari, D; Barrionuevo, F; Capozzo, A V; Rodríguez, L L; Borca, M V; Pérez-Filgueira, M

    2015-09-01

    Foot-and-mouth disease (FMD) is a highly contagious viral disease affecting biungulate species. Commercial vaccines, formulated with inactivated FMD virus (FMDV), are regularly used worldwide to control the disease. Here, we studied the generation of antibody responses in local lymphoid tissues along the respiratory system in vaccinated and further aerosol-infected cattle. Animals immunized with a high-payload monovalent FMD vaccine developed high titers of neutralizing antibodies at 7 days postvaccination (dpv), reaching a plateau at 29 dpv. FMDV-specific antibody-secreting cells (ASC), predominantly IgM, were evident at 7 dpv in the prescapular lymph node (LN) draining the vaccination site and in distal LN draining the respiratory mucosa, although in lower numbers. At 29 dpv, a significant switch to IgG1 was clear in prescapular LN, while FMDV-specific ASC were detected in all lymphoid tissues draining the respiratory tract, mostly as IgM-secreting cells. None of the animals (n = 10) exhibited FMD symptoms after oronasal challenge at 30 dpv. Three days postinfection, a large increase in ASC numbers and rapid isotype switches to IgG1 were observed, particularly in LN-draining virus replication sites already described. These results indicate for the first time that systemic FMD vaccination in cattle effectively promotes the presence of anti-FMDV ASC in lymphoid tissues associated with the respiratory system. Oronasal infection triggered an immune reaction compatible with a local anamnestic response upon contact with the replicating FMDV, suggesting that FMD vaccination induces the circulation of virus-specific B lymphocytes, including memory B cells that differentiate into ASC soon after contact with the infective virus. Over recent decades, world animal health organizations as well as national sanitary authorities have supported the use of vaccination as an essential component of the official FMD control programs in both endemic and disease-free settings. Very few

  13. 75 FR 60408 - Government Programs To Assist Businesses Protect Their Intellectual Property Rights (IPR) in...

    Science.gov (United States)

    2010-09-30

    ... DEPARTMENT OF COMMERCE International Trade Administration Government Programs To Assist Businesses Protect Their Intellectual Property Rights (IPR) in Foreign Markets: Request of the International Trade... Property Rights, International Trade Administration, Department of Commerce. ACTION: Request for written...

  14. US/Russian laboratory-to-laboratory program in materials protection, control and accounting at the RRC Kurchatov Institute

    International Nuclear Information System (INIS)

    Sukhoruchkin, V.; Roumiansev, A.; Shmelev, V.

    1996-01-01

    Six US DOE Laboratories are carrying out a program of cooperation with the Russian Research Center Kurchatov Institute (RRC KI) to improve the capabilities and facilities in nuclear material protection, control, and accounting (MPC ampersand A). In 1995, the primary emphasis of this program was the implementation of improved physical protection at a demonstration building at RRC KI, and the upgrading of the computerized MC ampersand A system, diagnostic instrumentation, and physical inventory procedures at a critical assembly within this building. Work continues in 1996 at the demonstration building but now also has begun at the two Kurchatov buildings which constitute the Central Storage Facility (CSF). At this facility, there will be upgrades in the physical inventory taking procedures, a test and evaluation of gamma-ray isotopic measurements, evaluations of nuclear material portal monitors and neutron-based measurement equipment as well as development of an improved computerized materials accounting system, implementation of bar code printing and reading equipment, development of tamper indicating device program, and substantial improvements in physical protection. Also, vulnerability assessments begun in 1995 are being extended to additional high priority facilities at Kurchatov

  15. Community-level characteristics and environmental factors of child respiratory illnesses in Southern Arizona

    Directory of Open Access Journals (Sweden)

    Nathan Lothrop

    2017-05-01

    Full Text Available Abstract Background Lower respiratory illnesses (LRIs and asthma are common diseases in children 0.05. Conclusions Our study revealed complex, multi-factorial associations between predictors and outcomes. Findings indicate that many rural areas with lower SES have distinct factors for childhood respiratory diseases that require further investigation. County-wide differences in maternal characteristics or agricultural land uses (not tested here may also play a role in Pima County residence protecting against hospitalizations, when compared to Maricopa County. By better understanding this and other relationships, more focused public health interventions at the community level could be developed to reduce and better control these diseases in children <5 years, who are more physiologically vulnerable.

  16. Increase of CTGF mRNA expression by respiratory syncytial virus infection is abrogated by caffeine in lung epithelial cells.

    Science.gov (United States)

    Kunzmann, Steffen; Krempl, Christine; Seidenspinner, Silvia; Glaser, Kirsten; Speer, Christian P; Fehrholz, Markus

    2018-04-16

    Respiratory syncytial virus (RSV) is a leading cause of severe lower respiratory tract infection in early childhood. Underlying pathomechanisms of elevated pulmonary morbidity in later infancy are largely unknown. We found that RSV-infected H441 cells showed increased mRNA expression of connective tissue growth factor (CTGF), a key factor in airway remodeling. Additional dexamethasone treatment led to further elevated mRNA levels, indicating additive effects. Caffeine treatment prevented RSV-mediated increase of CTGF mRNA. RSV may be involved in airway remodeling processes by increasing CTGF mRNA expression. Caffeine might abrogate these negative effects and thereby help to restore lung homeostasis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. RESPIRATORY GYMNASTICS AS A REHABILITATION MEANS FOR THE PRESCHOOL CHILDREN WITH THE RESPIRATORY PATHOLOGY

    Directory of Open Access Journals (Sweden)

    T.A. Shemyakina

    2007-01-01

    Full Text Available The researchers analyzed the efficacy of the new medical technology aimed at rehabilitation of the preschool children with the respiratory pathology. 177 children aged between 2 and 7 with recurrent respiratory diseases, bronchial asthma or chronic pathology of the end organs have been examined for 9 months. It was uncovered that among children (n = 90, who performed the sets of the therapeutic physical training and respiratory gymnastics according to the methods developed by the authors, the recurrence of the acute respiratory diseases and exacerbations of bronchial asthma was lower by 1,83 and 1,86 timers respectively. Besides, among children of this group the researchers noted the significant improvement of the physical qualities, spirometric indices and cytological picture of the substance removed from the nasal cavity if compared with the children from the screening group (n = 87, who performed the sets of the conventional gymnastics at the physical training lessons. Thus, the researchers proved the high efficacy of the proposed technology for the rehabilitation of the children, suffering from the chronic respiratory pathology.Key words: acute respiratory diseases, asthma, therapeutic physical training, respiratory gymnastics, children.

  18. Variables predictive of outcome in patients with acute hypercapneic respiratory failure treated with noninvasive ventilation

    International Nuclear Information System (INIS)

    Salahuddin, N.; Irfan, M.; Khan, S.; Naeem, M.; Haque, A.S.

    2010-01-01

    To assess results with NIV in acute hypercapneic respiratory failure and to identify outcome predictors. This was a retrospective observational study on consecutive patients presenting with acute type II respiratory failure and meeting criteria for NIV use over a 5 year period. Patients presenting with haemodynamic instability, inability to protect their airway, malignant arrhythmias and recent oesophageal surgery were excluded. Univariate and Multivariate regression analysis was used to determine the impact on survival. A p value of 35 Meq/L (adjusted Odds ratio 0.9; 95% CI 0.83, 0.98, p < 0.015) identified those less at risk for intubation. NIV was found to be both safe and effective in the management of acute hypercapneic respiratory failure. Sepsis and serum HCO/sub 3/ at admission identified patients having poor outcomes (JPMA 60:13; 2010). (author)

  19. Optimization programs of radiation protection applied to post-graduation and encouraging research

    International Nuclear Information System (INIS)

    Levy, Denise S.; Sordi, Gian Maria A.A.

    2013-01-01

    In 2011 we started the automation and integration of radiological protection optimization programs, in order to offer unified programs and inter-related information in Portuguese, providing Brazilian radioactive facilities a complete repository for research, consultation and information. The authors of this project extended it to postgraduate education, in order to encourage postgraduate students researches, expanding methods for enhancing student learning through the use of different combined resources, such as educational technology, information technology and group dynamics. This new methodology was applied in a postgraduate discipline at Instituto de Pesquisas Energeticas e Nucleares (IPEN), Brazil, in the postgraduate discipline entitled Fundamental Elements of Radiological Protection (TNA-5732). Students have six weeks to assimilate a complex content of optimization, considering national and international standards, guidelines and recommendations published by different organizations over the past decades. Unlike traditional classes, in which students receive prompt responses, this new methodology stimulates discussion, encouraging collective thinking processes and promoting ongoing personal reflection and researches. Case-oriented problem-solving permitted students to play different roles, promoting whole-group discussions and cooperative learning, approaching theory and practical applications. Students discussed different papers, published in international conferences, and their implications according to current standards. The automation of optimization programs was essential as a research tool during the course. The results of this experience were evaluated in two consecutive years. We had excellent results compared to the previous 14 years. The methodology has exceeded expectations and will be also applied in 2013 to ionizing radiation monitoring postgraduate classes. (author)

  20. Quality assurance program of a respiratory gating irradiation system based on external and internal fiducial markers; Programa de garantia de calidad de un sistema de irradiacion con control respiratorio basado en marcadores fiduciales externos e internos

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrilla, J.; Minambres Moro, A.

    2011-07-01

    Respiratory Gating involves the administration of radiation during treatment delivery within a particular portion of the patients breathing cycle, so the absorbed dose administration with respiratory control techniques requires specific quality control to ensure the correctness of the delivered dose. The establishment of a Quality Control Program (QC) is proposed for the Respiratory Gating based techniques in order to have a better understanding of how this system works and to know its associated dosimetric impact. The influence of the CT acquisition under respiratory motion conditions has been analyzed for the treatment isocenter localization, using internal and external fiducial markers with IGRT techniques that allow the correlation of the isocenter positioning with the phase of the respiratory cycle. Radiation delivery in the presence of intra fraction organ motion causes an averaging or blurring of the static dose distribution over the path of motion increasing the beam penumbra of the radiation field and reducing the therapeutic region when the irradiation is not breath controlled. The feasibility of intensity modulated treatments (IMRT) for both static and dynamic techniques, managed by respiratory control has been tested, demonstrating the possibility of synchronizing the movement of the leaves in the microfluorimeter collimator (mMLC) with the gated beam irradiation. (Author) 45 refs.

  1. Regional target program «Veteran’ eyesight» as a component of native system of social protection for population

    Directory of Open Access Journals (Sweden)

    O. O. Rozhko

    2014-06-01

    System of social protection for population in Ukraine is focused on provision of wide facilities for participation of the most vulnerable people, in particular, invalids, in social-economical and political life of society, realization of their intellectual and physical potential, creation of conditions for their normal vital activity. By this reason, public and local government authorities work out correspondent social protection programs. Program «Veteran’ Eyesight» is considered to be a novel one by its nature among such programs, during period of independence. Public authorities’ initiative was realized at the regional level for the first time in Ukraine; it dealt with conduction of address examination, diagnostics, and provision of invalids and veterans of the Great Patriotic War with remedies for eyesight correction by financial support from state budget. Principles of public administration were applied during «Veteran’ Eyesight» program realization for maximization of social effect.

  2. Harmful Effects of Formaldehyde and Possible Protective Effect of ...

    African Journals Online (AJOL)

    2017-05-22

    May 22, 2017 ... the ocular and respiratory system, but it also affects the nervous and genital system. ... possible protective effect of Nigella sativa on the trachea of rats. Niger ..... Vitamin A deficiency in the tracheal epithelium of rats has been ...

  3. Hippotherapy and respiratory muscle strength in children and adolescents with Down syndrome

    Directory of Open Access Journals (Sweden)

    Valéria Sovat de Freitas Costa

    Full Text Available Introduction Individuals with Down syndrome may have decreased respiratory muscle strength due to hypotonia, a common characteristic in this population. Objective To analyze the effects of a hippotherapy program on respiratory muscle strength in individuals with Down syndrome. Materials and methods The study included 41 subjects, 20 of which were in the hippotherapy practicing group (PG and 21 of which were in the non-practicing group (NPG. Study subjects were of both sexes, aged 7-13 years, and all diagnosed with Down syndrome. A manovacuometer was used to measure respiratory muscle strength, following the protocol proposed by Black and Hyatt (23. Statistical analysis was performed by means of descriptive distribution. After verifying normality and homoscedasticity of the variables, the Mann-Whitney test was used to determine differences between the means of the two groups (PG and NPG, and the Spearman’s rank correlation coefficient test was used to view possible relationships with age and time practicing hippotherapy. Significance was set at p < 0.05. Results and discussion Individuals who practiced hippotherapy showed improvements in both inspiratory and expiratory respiratory muscle strength, although no significant difference was demonstrated. Conclusion This study demonstrates that hippotherapy benefits respiratory muscle strength in individuals with Down syndrome, and that the youngest subjects had the best results.

  4. Effectiveness of China's National Forest Protection Program and nature reserves.

    Science.gov (United States)

    Ren, Guopeng; Young, Stephen S; Wang, Lin; Wang, Wei; Long, Yongcheng; Wu, Ruidong; Li, Junsheng; Zhu, Jianguo; Yu, Douglas W

    2015-10-01

    There is profound interest in knowing the degree to which China's institutions are capable of protecting its natural forests and biodiversity in the face of economic and political change. China's 2 most important forest-protection policies are its National Forest Protection Program (NFPP) and its national-level nature reserves (NNRs). The NFPP was implemented in 2000 in response to deforestation-caused flooding. We undertook the first national, quantitative assessment of the NFPP and NNRs to examine whether the NFPP achieved its deforestation-reduction target and whether the NNRs deter deforestation altogether. We used MODIS data to estimate forest cover and loss across mainland China (2000-2010). We also assembled the first-ever polygon dataset for China's forested NNRs (n = 237, 74,030 km(2) in 2000) and used both conventional and covariate-matching approaches to compare deforestation rates inside and outside NNRs (2000-2010). In 2000, 1.765 million km(2) or 18.7% of mainland China was forested (12.3% with canopy cover of ≥70%)) or woodland (6.4% with canopy cover <70% and tree plus shrub cover ≥40%). By 2010, 480,203 km(2) of forest and woodland had been lost, an annual deforestation rate of 2.7%. Forest-only loss was 127,473 km(2) (1.05% annually). In the NFPP provinces, the forest-only loss rate was 0.62%, which was 3.3 times lower than in the non-NFPP provinces. Moreover, the Landsat data suggest that these loss rates are overestimates due to large MODIS pixel size. Thus, China appears to have achieved, and even exceeded, its target of reducing deforestation to 1.1% annually in the NFPP provinces. About two-thirds of China's NNRs were effective in protecting forest cover (prevented loss 4073 km(2) unmatched approach; 3148 km(2) matched approach), and within-NNR deforestation rates were higher in provinces with higher overall deforestation. Our results indicate that China's existing institutions can protect domestic forest cover. © 2015 The Authors

  5. Respiratory muscle involvement in sarcoidosis.

    Science.gov (United States)

    Schreiber, Tina; Windisch, Wolfram

    2018-07-01

    In sarcoidosis, muscle involvement is common, but mostly asymptomatic. Currently, little is known about respiratory muscle and diaphragm involvement and function in patients with sarcoidosis. Reduced inspiratory muscle strength and/or a reduced diaphragm function may contribute to exertional dyspnea, fatigue and reduced health-related quality of life. Previous studies using volitional and non-volitional tests demonstrated a reduced inspiratory muscle strength in sarcoidosis compared to control subjects, and also showed that respiratory muscle function may even be significantly impaired in a subset of patients. Areas covered: This review examines the evidence on respiratory muscle involvement and its implications in sarcoidosis with emphasis on pathogenesis, diagnosis and treatment of respiratory muscle dysfunction. The presented evidence was identified by a literature search performed in PubMed and Medline for articles about respiratory and skeletal muscle function in sarcoidosis through to January 2018. Expert commentary: Respiratory muscle involvement in sarcoidosis is an underdiagnosed condition, which may have an important impact on dyspnea and health-related quality of life. Further studies are needed to understand the etiology, pathogenesis and extent of respiratory muscle involvement in sarcoidosis.

  6. Port Hope and area property value protection program: creating stability in the marketplace

    International Nuclear Information System (INIS)

    Gerestein, B.; Flynn, B.

    2006-01-01

    The Property Value Protection (PVP) Program, administered by the Low-Level Radioactive Waste Management Office (LLRWMO), functions as an integral part of the Port Hope Area Initiative, a $260M, 10-year project to clean up and safely manage low- level radioactive waste for the long-term in the Port Hope area. The PVP Program was established in March 2001 to compensate owners of residential, commercial or industrial properties in designated parts of the municipalities of Port Hope and Clarington. Compensation is awarded to owners if they realize financial loss on the sale or rental of their property or mortgage renewal difficulties as a result of the Initiative. Key features of the PVP Program include a claim process, an appeal process and the appointment of independent Compensation Officers to hear appeals. (author)

  7. US/Russian program in materials protection, control and accounting at the RRC Kurchatov Institute: 1997--1998

    International Nuclear Information System (INIS)

    Sukhoruchkin, V.; Rumyantsev, A.; Shmelev, V.

    1998-01-01

    Six US Department of Energy Laboratories are carrying out a program of cooperation with the Russian Research Center Kurchatov Institute to improve nuclear material protection, control and accounting (MPC and A) at Kurchatov. In 1997--1998 the primary thrust of this program has been directed to Building 106, which houses a number of test reactors and critical facilities. Substantial improvements in physical protection, upgrades in the physical inventory taking procedures, installation of equipment for the computerized materials accounting system, and installation of nuclear material portal monitors and neutron-based measurement equipment are being carried out at this facility. Software for the computerized accounting system, named KI-MACS, has been developed at Kurchatov and the system has been fully integrated with the bar code printing and reading equipment, electronic scales, and nondestructive assay equipment provided under this program. Additional 1997--1998 activities at Kurchatov include continuation of a tamper indicating device program, vulnerability assessments of several facilities, hosting of a Russian-American Workshop on Fissile Material Control and Accountability at Critical Facilities, and the development of accounting procedures for transfers of nuclear materials between material balance areas

  8. Low Tidal Volume Ventilation in Patients without Acute Respiratory Distress Syndrome: A Paradigm Shift in Mechanical Ventilation

    OpenAIRE

    Lipes, Jed; Bojmehrani, Azadeh; Lellouche, Francois

    2012-01-01

    Protective ventilation with low tidal volume has been shown to reduce morbidity and mortality in patients suffering from acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). Low tidal volume ventilation is associated with particular clinical challenges and is therefore often underutilized as a therapeutic option in clinical practice. Despite some potential difficulties, data have been published examining the application of protective ventilation in patients without lung inj...

  9. Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome.

    Science.gov (United States)

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2006-01-01

    To assess the effects of step-changes in tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury (ALI) or the acute respiratory distress syndrome (ARDS). Prospective, nonconsecutive patients with ALI/ARDS. Adult surgical, trauma, and medical intensive care units at a major inner-city, university-affiliated hospital. Ten patients with ALI/ARDS managed clinically with lung-protective ventilation. Five patients were ventilated at a progressively smaller tidal volume in 1 mL/kg steps between 8 and 5 mL/kg; five other patients were ventilated at a progressively larger tidal volume from 5 to 8 mL/kg. The volume mode was used with a flow rate of 75 L/min. Minute ventilation was maintained constant at each tidal volume setting. Afterward, patients were placed on continuous positive airway pressure for 1-2 mins to measure their spontaneous tidal volume. Work of breathing and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). Work of breathing progressively increased (0.86 +/- 0.32, 1.05 +/- 0.40, 1.22 +/- 0.36, and 1.57 +/- 0.43 J/L) at a tidal volume of 8, 7, 6, and 5 mL/kg, respectively. In nine of ten patients there was a strong negative correlation between work of breathing and the ventilator-to-patient tidal volume difference (R = -.75 to -.998). : The ventilator-delivered tidal volume exerts an independent influence on work of breathing during lung-protective ventilation in patients with ALI/ARDS. Patient work of breathing is inversely related to the difference between the ventilator-delivered tidal volume and patient-generated tidal volume during a brief trial of unassisted breathing.

  10. Simulation of The ICRP-30 Dosimetric Model for the Respiratory Tract

    International Nuclear Information System (INIS)

    Giaddui, T.; Atia, M. A.

    2004-01-01

    Matlab was used to write a simulation program (ACID1) to simulate the ICRP-30 dosimetric model for the respiratory tract. The program (a new version of the one presented at the sixth Arab conference held in Cairo 2002) calculates a series of dosimetric quantities for the reference man as a result of the inhalation of any radionuclide. The program also plots the variation of activity with time for all organs and provided with a graphical user interface to make it friendly user. The results obtained by this program was compared with similar results obtained by other source and found to be very close. (Authors)

  11. Dysrhythmias of the respiratory oscillator

    Science.gov (United States)

    Paydarfar, David; Buerkel, Daniel M.

    1995-03-01

    Breathing is regulated by a central neural oscillator that produces rhythmic output to the respiratory muscles. Pathological disturbances in rhythm (dysrhythmias) are observed in the breathing pattern of children and adults with neurological and cardiopulmonary diseases. The mechanisms responsible for genesis of respiratory dysrhythmias are poorly understood. The present studies take a novel approach to this problem. The basic postulate is that the rhythm of the respiratory oscillator can be altered by a variety of stimuli. When the oscillator recovers its rhythm after such perturbations, its phase may be reset relative to the original rhythm. The amount of phase resetting is dependent upon stimulus parameters and the level of respiratory drive. The long-range hypothesis is that respiratory dysrhythmias can be induced by stimuli that impinge upon or arise within the respiratory oscillator with certain combinations of strength and timing relative to the respiratory cycle. Animal studies were performed in anesthetized or decerebrate preparations. Neural respiratory rhythmicity is represented by phrenic nerve activity, allowing use of open-loop experimental conditions which avoid negative chemical feedback associated with changes in ventilation. In animal experiments, respiratory dysrhythmias can be induced by stimuli having specific combinations of strength and timing. Newborn animals readily exhibit spontaneous dysrhythmias which become more prominent at lower respiratory drives. In human subjects, swallowing was studied as a physiological perturbation of respiratory rhythm, causing a pattern of phase resetting that is characterized topologically as type 0. Computational studies of the Bonhoeffer-van der Pol (BvP) equations, whose qualitative behavior is representative of many excitable systems, supports a unified interpretation of these experimental findings. Rhythmicity is observed when the BvP model exhibits recurrent periods of excitation alternating with

  12. Thomas L Petty's lessons for the respiratory care clinician of today.

    Science.gov (United States)

    Pierson, David J

    2014-08-01

    Because of the importance of his original contributions and their practical relevance today, Thomas L Petty (1932-2009) was arguably the most important physician in the history of respiratory care. As much as any single individual, he was responsible for the concept of intensive and multidisciplinary respiratory care. In the 1960s and 1970s, he made key observations and introduced pioneering therapies in the ICU and in the home. He was the first to describe and name ARDS and to show how to use PEEP to treat life-threatening hypoxemia. He was one of the first anywhere to organize a pulmonary rehabilitation program and to show the beneficial effects of long-term oxygen therapy in COPD. Dr Petty emphasized the importance of practical, hands-on respiratory care education for both physicians and non-physicians using a collaborative team approach. He targeted educational activities and practical resources specifically to patients, and he showed how researchers and clinicians could interact responsibly with innovators in industry to the benefit of both. His life and career provide 6 important lessons for respiratory clinicians today and in the future: (1) whatever their roles, RTs and other clinicians in this field need to be experts in its core areas, such as mechanical ventilation, ARDS, and COPD; (2) respiratory care is a team activity: every member is important, and all the members need to communicate well and work together; (3) education needs to be targeted to those in the best position to benefit the patient, including primary care providers and family members; (4) everyone in the field needs to understand the important role of the respiratory care industry and to deal with it responsibly; (5) it must never be forgotten that it is all about the patient; and (6) respiratory care should be exciting and fun. Copyright © 2014 by Daedalus Enterprises.

  13. Fire protection for telecommunications central offices

    International Nuclear Information System (INIS)

    McKenna, L.A. Jr.

    1990-01-01

    The provision of continuous, uninterrupted telecommunications service is vital to modern life. In order to provide uninterrupted service to customers, a service continuity program has been in place with AT and T for many years. This program integrates many different protection strategies and plans, each designed to mitigate one of the many threats to service continuity. The fire protection program implemented within AT and T is a part of this service continuity program. In the design of this program, a number of unusual problems had to be addressed due to the service continuity requirements. Typical solutions to fire protection problems (ignition prevention, detection, and suppression) which are embodied in building and fire prevention codes are inadequate to provide service continuity. This presentation outlines the basic arrangement of a telecommunications central office, the specific fire protection problems encountered, the fire protection philosophy developed through the use of a systems approach, and the implementation of the fire protection program. Special emphasis is placed on the strategies employed in lieu of more traditional fire protection schemes and the stimuli for selecting them

  14. Iterative integral parameter identification of a respiratory mechanics model

    Directory of Open Access Journals (Sweden)

    Schranz Christoph

    2012-07-01

    Full Text Available Abstract Background Patient-specific respiratory mechanics models can support the evaluation of optimal lung protective ventilator settings during ventilation therapy. Clinical application requires that the individual’s model parameter values must be identified with information available at the bedside. Multiple linear regression or gradient-based parameter identification methods are highly sensitive to noise and initial parameter estimates. Thus, they are difficult to apply at the bedside to support therapeutic decisions. Methods An iterative integral parameter identification method is applied to a second order respiratory mechanics model. The method is compared to the commonly used regression methods and error-mapping approaches using simulated and clinical data. The clinical potential of the method was evaluated on data from 13 Acute Respiratory Distress Syndrome (ARDS patients. Results The iterative integral method converged to error minima 350 times faster than the Simplex Search Method using simulation data sets and 50 times faster using clinical data sets. Established regression methods reported erroneous results due to sensitivity to noise. In contrast, the iterative integral method was effective independent of initial parameter estimations, and converged successfully in each case tested. Conclusion These investigations reveal that the iterative integral method is beneficial with respect to computing time, operator independence and robustness, and thus applicable at the bedside for this clinical application.

  15. The effects of carbon monoxide on respiratory chemoreflexes in humans

    International Nuclear Information System (INIS)

    Vesely, A.E.; Somogyi, R.B.; Sasano, Hiroshi; Sasano, Nobuko; Fisher, J.A.; Duffin, James

    2004-01-01

    As protection against low-oxygen and high-carbon-dioxide environments, the respiratory chemoreceptors reflexly increase breathing. Since CO is also frequently present in such environments, it is important to know whether CO affects the respiratory chemoreflexes responsiveness. Although the peripheral chemoreceptors fail to detect hypoxia produced by CO poisoning, whether CO affects the respiratory chemoreflex responsiveness to carbon dioxide is unknown. The responsiveness of 10 healthy male volunteers were assessed before and after inhalation of ∼1200 ppm CO in air using two iso-oxic rebreathing tests; hypoxic, to emphasize the peripheral chemoreflex, and hyperoxic, to emphasize the central chemoreflex. Although mean (SEM) COHb values of 10.2 (0.2)% were achieved, no statistically significant effects of CO were observed. The average differences between pre- and post-CO values for ventilation response threshold and sensitivity were -0.5 (0.9) mmHg and 0.8 (0.3) L/min/mmHg, respectively, for hyperoxia, and 0.7 (1.1) mmHg and 1.2 (0.8) L/min/mmHg, respectively, for hypoxia. The 95% confidence intervals for the effect of CO were small. We conclude that environments with low levels of CO do not have a clinically significant effect acutely on either the central or the peripheral chemoreflex responsiveness to carbon dioxide

  16. Respiratory effort from the photoplethysmogram.

    Science.gov (United States)

    Addison, Paul S

    2017-03-01

    The potential for a simple, non-invasive measure of respiratory effort based on the pulse oximeter signal - the photoplethysmogram or 'pleth' - was investigated in a pilot study. Several parameters were developed based on a variety of manifestations of respiratory effort in the signal, including modulation changes in amplitude, baseline, frequency and pulse transit times, as well as distinct baseline signal shifts. Thirteen candidate parameters were investigated using data from healthy volunteers. Each volunteer underwent a series of controlled respiratory effort maneuvers at various set flow resistances and respiratory rates. Six oximeter probes were tested at various body sites. In all, over three thousand pleth-based effort-airway pressure (EP) curves were generated across the various airway constrictions, respiratory efforts, respiratory rates, subjects, probe sites, and the candidate parameters considered. Regression analysis was performed to determine the existence of positive monotonic relationships between the respiratory effort parameters and resulting airway pressures. Six of the candidate parameters investigated exhibited a distinct positive relationship (poximeter probe and an ECG (P2E-Effort) and the other using two pulse oximeter probes placed at different peripheral body sites (P2-Effort); and baseline shifts in heart rate, (BL-HR-Effort). In conclusion, a clear monotonic relationship was found between several pleth-based parameters and imposed respiratory loadings at the mouth across a range of respiratory rates and flow constrictions. The results suggest that the pleth may provide a measure of changing upper airway dynamics indicative of the effort to breathe. Copyright © 2017 The Author. Published by Elsevier Ltd.. All rights reserved.

  17. Extracorporeal respiratory support in adult patients.

    Science.gov (United States)

    Romano, Thiago Gomes; Mendes, Pedro Vitale; Park, Marcelo; Costa, Eduardo Leite Vieira

    2017-01-01

    In patients with severe respiratory failure, either hypoxemic or hypercapnic, life support with mechanical ventilation alone can be insufficient to meet their needs, especially if one tries to avoid ventilator settings that can cause injury to the lungs. In those patients, extracorporeal membrane oxygenation (ECMO), which is also very effective in removing carbon dioxide from the blood, can provide life support, allowing the application of protective lung ventilation. In this review article, we aim to explore some of the most relevant aspects of using ECMO for respiratory support. We discuss the history of respiratory support using ECMO in adults, as well as the clinical evidence; costs; indications; installation of the equipment; ventilator settings; daily care of the patient and the system; common troubleshooting; weaning; and discontinuation. RESUMO Em pacientes com insuficiência respiratória grave (hipoxêmica ou hipercápnica), o suporte somente com ventilação mecânica pode ser insuficiente para suas necessidades, especialmente quando se tenta evitar o uso de parâmetros ventilatórios que possam causar danos aos pulmões. Nesses pacientes, extracorporeal membrane oxygenation (ECMO, oxigenação extracorpórea por membrana), que também é muito eficaz na remoção de dióxido de carbono do sangue, pode manter a vida, permitindo o uso de ventilação pulmonar protetora. No presente artigo de revisão, objetivamos explorar alguns dos aspectos mais relevantes do suporte respiratório por ECMO. Discutimos a história do suporte respiratório por ECMO em adultos; evidências clínicas; custos; indicações; instalação do equipamento; parâmetros ventilatórios; cuidado diário do paciente e do sistema; solução de problemas comuns; desmame e descontinuação.

  18. Effect of respiratory function training on respiratory function of patients with severe cerebrovascular disease

    Directory of Open Access Journals (Sweden)

    Ming GUO

    2017-07-01

    Full Text Available Objective To investigate the effect of respiratory function training on respiratory function and conscious state of patients with severe cerebrovascular disease (SCVD.  Methods A total of 27 patients with SCVD were divided into control group (N = 17 and observation group (N = 10. Control group received routine drug and rehabilitation treatment, and observation group was added respiratory function training based on routine treatment. The respiratory rate, tidal volume (TV, heart rate, blood pressure and artery oxygen saturation (SaO2 of patients were monitored by breathing machine before and after 4-week treatment. Meanwhile, arterial blood gas analysis was used to detect arterial partial pressure of oxygen (PaO2, oxygenation index, partial pressure of carbon dioxide (PaCO2 and pH value. At the same time, Glasgow Coma Scale (GCS was used to evaluate the conscious state of patients.  Results All patients successfully completed 4-week rehabilitation training, without asphyxia, arrhythmia or other adverse events. Compared with before training, the respiratory rate (P = 0.006 and pH value (P = 0.010 were significantly decreased, while SaO2 (P = 0.001, oxygenation index (P = 0.000 and GCS scores (P = 0.004, 0.017 were significantly increased in both groups of patients after training. There was no statistically significant difference between 2 groups on respiratory function indexes and GCS scores after training (P > 0.05, for all. Conclusions Respiratory function training did not significantly improve the respiratory function and conscious state of patients with SCVD, yet to be further studied. Randomized controlled clinical trials with larger, layered samples and long-term prognosis observation are needed. Examination method of respiratory function of SCVD patients is also a topic to be explored.  DOI: 10.3969/j.issn.1672-6731.2017.04.007

  19. Particle deposition and clearance of atmospheric particles in the human respiratory tract during LACE 98

    Science.gov (United States)

    Bundke, U.; Hänel, G.

    2003-04-01

    During the LACE 98footnote{Lindenberg Aerosol Characterization Experiment, (Germany) 1998} experiment microphysical, chemical and optical properties of atmospheric particles were measured by several groups. (Bundke et al.). The particle deposition and clearance of the particles in the human respiratory tract was calculated using the ICRP (International Commission on Radiological Protection) deposition and clearance model (ICRP 1994). Particle growth as function of relative humidity outside the body was calculated from measurement data using the model introduced by Bundke et al.. Particle growth inside the body was added using a non-equilibrium particle growth model. As a result of the calculations, time series of the total dry particle mass and -size distribution were obtained for all compartments of the human respiratory tract defined by ICRP 1994. The combined ICRP deposition and clearance model was initialized for different probationers like man, woman, children of different ages and several circumstances like light work, sitting, sleeping etc. Keeping the conditions observed during LACE 98 constant a approximation of the aerosol burdens of the different compartments was calculated up to 4 years of exposure and compared to the results from Snipes et al. for the "Phoenix" and "Philadelphia" aerosol. References: footnotesize{ Bundke, U. et al.,it{Aerosol Optical Properties during the Lindenberg Aerosol Characterization Experiment (LACE 98)} ,10.1029/2000JD000188, JGR, 2002 ICRP,it{Human Respiratory Tract Model for Radiological Protection, Bd. ICRP Publication 66}, Annals of the ICRP, 24,1-3, Elsevier Science, Ocford, 1994 Snipes et al. ,it{The 1994 ICRP66 Human Respiratory Tract Model as a Tool for predicting Lung Burdens from Exposure to Environmental Aerosols}, Appl. Occup. Environ. Hyg., 12, 547-553,1997}

  20. Chronic Respiratory Diseases in the Regions of Northern Russia: Epidemiological Distinctions in the Results of a National Population Study.

    Science.gov (United States)

    Gambaryan, Marine H; Shalnova, Svetlana A; Deev, Alexander D; Drapkina, Oxana M

    2017-07-26

    The aim of the study is to investigate the epidemiological situation regarding chronic respiratory diseases in populations that inhabit different climatic-geographical regions of Russia, and to develop targeted programs for prevention of these diseases. (1) a comparative analysis of the standardized mortality data in Russia and other selected regions of the Russian North using the European standard for respiratory diseases, in a population aged 25-64; and (2) data from a randomized cross-sectional epidemiological study, with subjects from three different climatic-geographical regions of Russia. (1) the respiratory disease-related mortality rates in the majority of Russian Northern regions were much higher compared to the national average. Although death rates from chronic lower respiratory diseases were higher among the Northern regions and in the whole of Russia relative to the countries of European Union (EU), the cause of death in the populations of the Northern regions tend to be lower respiratory infections and pneumonia; and (2) despite the absence of any significant differences in the prevalence of smoking, the prevalence of chronic respiratory diseases (COPD) is significantly higher in Far North Yakutsk compared to the other two regions in this study-Chelyabinsk and Vologda. The status of hyperborean had the highest chance of a significant contribution to COPD and cardiorespiratory pathology among all other risk factors. The results revealed a need for effective targeted strategies for primary and secondary prevention of chronic respiratory diseases for the populations of the Northern regions of Russia. The revealed regional distinctions regarding the prevalence of, and mortality from, chronic respiratory diseases should be taken into consideration when designing integrated programs for chronic non-communicable disease prevention in these regions.