WorldWideScience

Sample records for respiratory face mask

  1. A novel anti-influenza copper oxide containing respiratory face mask.

    Science.gov (United States)

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.

  2. Face mask spirometry and respiratory pressures in normal subjects.

    NARCIS (Netherlands)

    Wohlgemuth, M.; Kooi, E.L. van der; Hendriks, J.C.M.; Padberg, G.W.A.M.; Folgering, H.T.M.

    2003-01-01

    Spirometry and maximal respiratory pressures are pulmonary function parameters commonly used to evaluate respiratory function. Prediction values are available for conventional lung function devices using a standard tube or flanged type of mouthpiece connection. This equipment is not suitable for

  3. A novel anti-influenza copper oxide containing respiratory face mask.

    Directory of Open Access Journals (Sweden)

    Gadi Borkow

    Full Text Available BACKGROUND: Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. METHODOLOGY/PRINCIPAL FINDINGS: We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10TCID(50 of human influenza A virus (H1N1 and avian influenza virus (H9N2, respectively, under simulated breathing conditions (28.3 L/min. Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10TCID(50, while 4.67+/-1.35 log(10TCID(50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10TCID(50 and from the control masks 5.03+/-0.54 log(10TCID(50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. CONCLUSIONS/SIGNIFICANCE: Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical

  4. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses.

    Science.gov (United States)

    Zhou, S Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W; Suchmann, Donna B; Ijaz, M Khalid

    2018-03-01

    Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus ( S . aureus ), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S . aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM 2.5 ). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S . aureus ) were not significantly different. The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM 2.5 ) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against

  5. A low cost, simplified, and scaleable pneumotachograph and face mask for neonatal mouse respiratory measurements.

    Science.gov (United States)

    Sun, Jenny J; Nanu, Roshan; Ray, Russell S

    2017-07-01

    Neonatal respiratory disorders are a leading cause of perinatal mortality due to complications resulting from premature births and prenatal exposure to drugs of abuse, but optimal treatments for these symptoms are still unclear due to a variety of confounds and risk factors. Mouse models present an opportunity to study the underlying mechanisms and efficacy of potential treatments of these conditions with controlled variables. However, measuring respiration in newborn mice is difficult and commercial components are expensive and often require modification, creating a barrier and limiting our understanding of the short and long-term effects of birth complications on respiratory function. Here, we present an inexpensive and simple flow through pneumotachograph and face mask design that can be easily scaled for parallel, high-throughput assays measuring respiration in neonatal mouse pups. The final apparatus consists of three main parts: a water-jacketed chamber, an integrated support tray for the pup, and a pneumotachograph consisting of a two side-arm air channel that is attached to a pressure transducer. The pneumotach showed a linear response and clean, steady respiratory traces in which apneas and sighs were clearly visible. Administration of caffeine in P0.5 CD1 wildtype neonates resulted in an increase in tidal volume, minute ventilation, and minute ventilation normalized to oxygen consumption as well as a decrease in periodic instability. The described methods offer a relatively simple and inexpensive approach to constructing a pneumotachograph for non-invasive measurements of neonatal mouse respiration, enhancing accessibility and enabling the high-throughput and parallel characterizations of neonatal respiratory disorders and potential pharmacological therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Professional and home-made face masks reduce exposure to respiratory infections among the general population.

    Science.gov (United States)

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-07-09

    Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission.

  7. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial.

    Science.gov (United States)

    Sadeghi, Somayeh; Fakharian, Atefeh; Nasri, Peiman; Kiani, Arda

    2017-01-01

    Background . There is a growing controversy about the use of oronasal masks (ONM) or total facemask (TFM) in noninvasive positive pressure ventilation (NPPV), so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods . Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t -test and chi-square test. Repeated measures ANOVA and Mann-Whitney U test were used to compare clinical and laboratory data. Results . There were no differences in venous blood gas (VBG) values between the two groups ( P > 0.05). However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2) ( P = 0.04). Patient comfort and acceptance were statistically similar in both groups ( P > 0.05). Total time of NPPV was also similar in the two groups ( P > 0.05). Conclusions . TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  8. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial

    Directory of Open Access Journals (Sweden)

    Somayeh Sadeghi

    2017-01-01

    Full Text Available Background. There is a growing controversy about the use of oronasal masks (ONM or total facemask (TFM in noninvasive positive pressure ventilation (NPPV, so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods. Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t-test and chi-square test. Repeated measures ANOVA and Mann–Whitney U test were used to compare clinical and laboratory data. Results. There were no differences in venous blood gas (VBG values between the two groups (P>0.05. However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2 (P=0.04. Patient comfort and acceptance were statistically similar in both groups (P>0.05. Total time of NPPV was also similar in the two groups (P>0.05. Conclusions. TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  9. A respiratory mask for resting and exercising dogs.

    Science.gov (United States)

    Stavert, D M; Reischl, P; O'Loughlin, B J

    1982-02-01

    A respiratory face mask has been developed for use with unsedated beagles trained to run on a treadmill. The latex rubber mask, shaped to fit the animal's muzzle, incorporates two modified, commercially available, pulmonary valves for separating inspiratory and expiratory flows. The mask has a dead space of 30 cm3 and a flow resistance below 1 cmH2O . 1(-1) . s. The flexible mask is used to measure breath-by-breath respiratory variables over extended periods of time during rest and exercise.

  10. Face mask ventilation--the dos and don'ts.

    Science.gov (United States)

    Wood, Fiona E; Morley, Colin J

    2013-12-01

    Face mask ventilation provides respiratory support to newly born or sick infants. It is a challenging technique and difficult to ensure that an appropriate tidal volume is delivered because large and variable leaks occur between the mask and face; airway obstruction may also occur. Technique is more important than the mask shape although the size must appropriately fit the face. The essence of the technique is to roll the mask on to the face from the chin while avoiding the eyes, with a finger and thumb apply a strong even downward pressure to the top of the mask, away from the stem and sloped sides or skirt of the mask, place the other fingers under the jaw and apply a similar upward pressure. Preterm infants require continuous end-expiratory pressure to facilitate lung aeration and maintain lung volume. This is best done with a T-piece device, not a self-inflating or flow-inflating bag. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Mask versus Nasal Tube for Stabilization of Preterm Infants at Birth: Respiratory Function Measurements.

    Science.gov (United States)

    van Vonderen, Jeroen J; Kamlin, C Omar; Dawson, Jennifer A; Walther, Frans J; Davis, Peter G; te Pas, Arjan B

    2015-07-01

    To compare the nasal tube with face mask as interfaces for stabilization of very preterm infants at birth by using physiological measurements of leak, obstruction, and expired tidal volumes during positive pressure ventilation (PPV). In the delivery room, 43 infants face mask. Respiratory function, heart rate, and oxygen saturation were measured. Occurrence of obstruction, amount of leak, and tidal volumes were compared using a Mann-Whitney U test or a Fisher exact test. The first 5 minutes after initiation of PPV were analyzed (1566 inflations in the nasal tube group and 1896 inflations in the face mask group). Spontaneous breathing coincided with PPV in 32% of nasal tube and 34% of face mask inflations. During inflations, higher leak was observed using nasal tube compared with face mask (98% [33%-100%] vs 14 [0%-39%]; P face mask (0.0 [0.0-3.1] vs 9.9 [5.5-12.8] mL/kg; P 0.05). Heart rate was not significantly different between groups, but oxygen saturation was significantly lower in the nasal tube group the first 2 minutes after start of respiratory support. The use of a nasal tube led to large leak, more obstruction, and inadequate tidal volumes compared with face mask. Trial registration Registered with the Dutch Trial Registry (NTR 2061) and the Australia and New Zealand Clinical Trials Register (ACTRN 12610000230055). Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Comparison of face masks in the bag-mask ventilation of a manikin.

    Science.gov (United States)

    Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S

    2006-02-01

    We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

  13. Mask-wearing and respiratory infection in healthcare workers in Beijing, China

    Directory of Open Access Journals (Sweden)

    Peng Yang

    Full Text Available OBJECTIVES: The aim of the study was to determine rates of mask-wearing, of respiratory infection and the factors associated with mask-wearing and of respiratory infection in healthcare workers (HCWs in Beijing during the winter of 2007/2008. METHODS: We conducted a survey of 400 HCWs working in eight hospitals in Beijing by face to face interview using a standardized questionnaire. RESULTS: We found that 280/400 (70.0% of HCWs were compliant with mask-wearing while in contact with patients. Respiratory infection occurred in 238/400 (59.5% subjects from November, 2007 through February, 2008. Respiratory infection was higher among females (odds ratio [OR], 2.00 [95% confidence interval {CI}, 1.16-3.49] and staff working in larger hospitals (OR, 1.72 [95% CI, 1.092.72], but was lower among subjects with seasonal influenza vaccination (OR, 0.46 [95% CI, 0.280.76], wearing medical masks (reference: cotton-yarn; OR, 0.60 [95% CI, 0.39-0.91] or with good mask-wearing adherence (OR, 0.60 [95% CI, 0.37-0.98]. The risk of respiratory infection of HCWs working in low risk areas was similar to that of HCWs in high risk area. CONCLUSION: Our data suggest that female HCWs and staffs working in larger hospitals are the focus of prevention and control of respiratory infection in Beijing hospitals. Mask-wearing and seasonal influenza vaccination are protective for respiratory infection in HCWs; the protective efficacy of medical masks is better than that of cotton yarn ones; respiratory infection of HCWs working in low risk areas should also be given attention.

  14. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.

    Science.gov (United States)

    Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano

    2015-08-01

    To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    Science.gov (United States)

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  16. X-ray face mask and chest shield device

    International Nuclear Information System (INIS)

    Moti, S.

    1981-01-01

    A protective face mask is designed to shield an x-ray technician or machine operator primarily from random secondary or scatter x-rays deflected towards his face, head and neck by the table, walls, equipment and other reflecting elements in an x-ray room or chamber. The face mask and chest shield device can be mounted on a patient's shoulders in reverse attitude to protect the back of a patient's head and neck from the x-ray beam. The face mask is relatively or substantially transparent and contains lead in combination with a plastic ionomer or comonomer, which to a degree absorbs or resists penetration of the random deflected secondary or scatter x-rays or the x-ray beam through the mask. The face mask is removably attachable to the chest shield for easy application of the device to and support upon the shoulders of the technician or the patient. (author)

  17. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.

    1982-01-01

    An x-ray protective face mask is made of a relatively transparent lead containing radiation shielding plastics material, and is removably attachable to a chest or bib shield for application of the device to and support upon the shoulders of a technician or a patient. Alternatively, the face mask is formed of a lens portion supported in a plastics frame, upon the lower portion of which is removably attached a bib shield that in turn is removably attachable to an apron. The frame of the face mask, bib shield and apron are preferably lined with lead sheets to protect the neck, face, chest and body of the technician from the random secondary or scatter x-ray beams. The face mask and bib shield can be formed of a moulded plastics material as a unitary device, the lens portion being attached to the frame therefor. (author)

  18. Experiments on the evaluation of protection provided by full-face masks as worn

    International Nuclear Information System (INIS)

    Kinouchi, Nobuyuki; Ikezawa, Yoshio; Izumi, Yukio.

    1991-01-01

    The performance of a dust respirator is affected mostly by the leakage through the interstice between mask and face. Mask man-test using NaCl aerosols has been developed to evaluate protection provided by worn masks. However, there were some problems in application of man-test to field test. The sampling method of the NaCl aerosols inside the mask was discussed. The tool for sampling operated easily was selected, and the best sampling position at the mask was decided. The correction of the measured values was also discussed. Because of NaCl aerosols deposition in the respiratory tract and sampling lines, the leakage might be underestimated. The correction coefficient was experimentally measured and discussed. (author)

  19. Face and Mask: A Double History

    NARCIS (Netherlands)

    Saramifar, Y.

    2017-01-01

    How often have you read an article and then Googled the author to see him or her? How often have you swiped right or left just looking at the faces without reading the profile on Tinder? Seeking faces and trying to put faces to names happens every day but Hans Belting has brought together Face and

  20. Dead space variability of face masks for valved holding chambers.

    Science.gov (United States)

    Amirav, Israel; Newhouse, Michael T

    2008-03-01

    Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV and thus different performance. To compare both physical dead space and functional dead space of different face masks under various applied pressures. The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV). There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility. Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs.

  1. An investigation into the efficiency of disposable face masks.

    Science.gov (United States)

    Rogers, K B

    1980-01-01

    Disposable face masks used in hospitals have been assessed for the protection afforded the patient and the wearer by challenges of simulated natural conditions of stress. Operating theatre masks made of synthetic materials allow the wearer to breathe through the masks, and these have been shown to protect the patient well but the wearer slightly less. Cheaper paper masks are worn for ward duties, and of these only the Promask protected in area in front of the wearer: air does not pass through this mask, expired air is prevented from passing forward, and the wearer breathes unfiltered air. All the other paper masks tested allowed many bacteria-laden particles to pass through them. PMID:7440756

  2. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    OpenAIRE

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively ev...

  3. Respiratory source control using a surgical mask: An in vitro study.

    Science.gov (United States)

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  4. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    Science.gov (United States)

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average

  5. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    Science.gov (United States)

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected

  6. Design of aerosol face masks for children using computerized 3D face analysis.

    Science.gov (United States)

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Raviv, Dan; Kimmel, Ron; Waisman, Dan; Newhouse, Michael T

    2014-08-01

    Aerosol masks were originally developed for adults and downsized for children. Overall fit to minimize dead space and a tight seal are problematic, because children's faces undergo rapid and marked topographic and internal anthropometric changes in their first few months/years of life. Facial three-dimensional (3D) anthropometric data were used to design an optimized pediatric mask. Children's faces (n=271, aged 1 month to 4 years) were scanned with 3D technology. Data for the distance from the bridge of the nose to the tip of the chin (H) and the width of the mouth opening (W) were used to categorize the scans into "small," "medium," and "large" "clusters." "Average" masks were developed from each cluster to provide an optimal seal with minimal dead space. The resulting computerized contour, W and H, were used to develop the SootherMask® that enables children, "suckling" on their own pacifier, to keep the mask on their face, mainly by means of subatmospheric pressure. The relatively wide and flexible rim of the mask accommodates variations in facial size within and between clusters. Unique pediatric face masks were developed based on anthropometric data obtained through computerized 3D face analysis. These masks follow facial contours and gently seal to the child's face, and thus may minimize aerosol leakage and dead space.

  7. Measurements from preterm infants to guide face mask size.

    Science.gov (United States)

    O'Shea, Joyce E; Thio, Marta; Owen, Louise S; Wong, Connie; Dawson, Jennifer A; Davis, Peter G

    2016-07-01

    International guidelines recommend that an appropriately sized face mask for providing positive pressure ventilation should cover the mouth and nose but not the eyes and should not overlap the chin. This study aimed to measure the dimensions of preterm infants' faces and compare these with the size of the most commonly available face masks (external diameter 50 mm) and the smallest masks available (external diameters 35 and 42 mm). Infants 24-33 weeks' postmenstrual age (PMA) were photographed in a standardised manner. Images were analysed using ImageJ software (National Institute of Health, USA) to calculate the distance from the nasofrontal groove to the mental protuberance. This facial measurement corresponds to the external diameter of an optimally fitting mask. A cohort of 107 infants between 24 and 33 weeks' gestational age, including at least 10 infants per week of gestation, was photographed within 72 h after birth and weekly until 33 weeks' PMA. 347 photographs were analysed. Infants of 24, 26, 28, 30 and 32 weeks' PMA had mean (SD) facial measurements of 32 (2), 36 (3), 38 (4), 41 (2) and 43 (4) mm, respectively. There were no significant differences when examined by gender or when small for gestational age infants were excluded. The smallest size of some brands of mask is too large for many preterm infants. Masks of 35 mm diameter are suitable for infants Masks of 42 mm diameter are suitable for infants 27-33 weeks' PMA or 750-2500 g. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    Science.gov (United States)

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  9. Oral mask ventilation is more effective than face mask ventilation after nasal surgery.

    Science.gov (United States)

    Yazicioğlu, Dilek; Baran, Ilkay; Uzumcugil, Filiz; Ozturk, Ibrahim; Utebey, Gulten; Sayın, M Murat

    2016-06-01

    To evaluate and compare the face mask (FM) and oral mask (OM) ventilation techniques during anesthesia emergence regarding tidal volume, leak volume, and difficult mask ventilation (DMV) incidence. Prospective, randomized, crossover study. Operating room, training and research hospital. American Society of Anesthesiologists physical status I and II adult patients scheduled for nasal surgery. Patients in group FM-OM received FM ventilation first, followed by OM ventilation, and patients in group OM-FM received OM ventilation first, followed by FM ventilation, with spontaneous ventilation after deep extubation. The FM ventilation was applied with the 1-handed EC-clamp technique. The OM was placed only over the mouth, and the 1-handed EC-clamp technique was used again. A child's size FM was used for the OM ventilation technique, the mask was rotated, and the inferior part of the mask was placed toward the nose. The leak volume (MVleak), mean airway pressure (Pmean), and expired tidal volume (TVe) were assessed with each mask technique for 3 consecutive breaths. A mask ventilation grade ≥3 was considered DMV. DMV occurred more frequently during FM ventilation (75% with FM vs 8% with OM). In the FM-first sequence, the mean TVe was 249±61mL with the FM and 455±35mL with the OM (P=.0001), whereas in the OM-first sequence, it was 276±81mL with the FM and 409±37mL with the OM (P=.0001). Regardless of the order used, the OM technique significantly decreased the MVleak and increased the TVe when compared to the FM technique. During anesthesia emergence after nasal surgery the OM may offer an effective ventilation method as it decreases the incidence of DMV and the gas leak around the mask and provides higher tidal volume delivery compared with FM ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Techniques of preoxygenation in patients with ineffective face mask seal

    Directory of Open Access Journals (Sweden)

    Pankaj Kundra

    2013-01-01

    Full Text Available Background: Ineffective face mask seal is the most common cause for suboptimal pre-oxygenation. Room air entrainment can be more with vital capacity (VC breaths when the mask is not a tight fit. Aims: This study was designed to compare 5 min tidal volume (TV breathing and eight VC breaths in patients with ineffective face mask seal. Methods: Twenty eight ASA I adults with ineffective face mask seal were randomized to breathe 100% oxygen at normal TV for 5 min (Group TV and eight VC breaths (Group VC in a cross over manner through circle system at 10 L/min. End tidal oxygen concentration (EtO 2 and arterial blood gas analysis was performed to evaluate oxygenation with each technique. Statistical Analysis: Data were analysed using SPSS statistical software, version 16. Friedman′s two-way analysis of variance by ranks was used for non-parametric data. Results: Significant increase in EtO 2 (median 90 and PaO 2 (228.85 was seen in group TV when compared to group VC (EtO 2 median 85, PaO 2 147.65, P<0.05. Mean total ventilation volume in 1 min in group VC was 9.4±3.3 L/min and more than fresh gas flow (10 L/min in seven patients. In group TV, the fresh gas flow (50 L/5 min was sufficient at normal TV (mean total ventilation in 5 min 36.7±6.3 L/min. Conclusions: TV breathing for 5 min provides better pre-oxygenation in patients with ineffective mask seal with fresh gas flow of 10 L/min delivered through a circle system.

  11. Face Masks for Noninvasive Ventilation: Fit, Excess Skin Hydration, and Pressure Ulcers.

    Science.gov (United States)

    Visscher, Marty O; White, Cynthia C; Jones, Jennifer M; Cahill, Thomas; Jones, Donna C; Pan, Brian S

    2015-11-01

    Pressure ulcers (stages III and IV) are serious safety events (ie, never events). Healthcare institutions are no longer reimbursed for costs to care for affected patients. Medical devices are the leading cause of pediatric pressure ulcers. Face masks for noninvasive ventilation were associated with a high percentage of pressure ulcers at our institution. A prospective cohort study investigated factors contributing to pressure ulcer development in 50 subjects using face masks for noninvasive ventilation. Color imaging, 3-dimensional surface imaging, and skin hydration measurements were used to identify early skin compromise and evaluate 3 interventions to reduce trauma: (1) a silicone foam dressing, (2) a water/polyethylene oxide hydrogel dressing, and (3) a flexible cloth mask. A novel mask fit technique was used to examine the impact of fit on the potential for skin compromise. Fifty subjects age 10.4 ± 9.1 y participated with color images for 22, hydration for 34, and mask fit analysis for 16. Of these, 69% had diagnoses associated with craniofacial anomalies. Stage I pressure ulcers were the most common injury. Skin hydration difference was 317 ± 29 for sites with erythema versus 75 ± 28 for sites without erythema (P skin erythema and pressure ulcers. This fit method is currently being utilized to select best-fit masks from available options, to identify the potential areas of increased tissue pressure, and to prevent skin injuries and their complications. Improvement of mask fit is an important priority for improving respiratory outcomes. Strategies to maintain normal skin hydration are important for protecting tissue integrity. Copyright © 2015 by Daedalus Enterprises.

  12. Masking with faces in central visual field under a variety of temporal schedules.

    Science.gov (United States)

    Daar, Marwan; Wilson, Hugh R

    2015-11-01

    With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    Science.gov (United States)

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to

  14. Pressure Ulcer Incidence in Patients Wearing Nasal-Oral Versus Full-Face Noninvasive Ventilation Masks.

    Science.gov (United States)

    Schallom, Marilyn; Cracchiolo, Lisa; Falker, Antoinette; Foster, Jennifer; Hager, JoAnn; Morehouse, Tamara; Watts, Peggy; Weems, Linda; Kollef, Marin

    2015-07-01

    Device-related pressure ulcers from noninvasive ventilation masks alter skin integrity and cause patients discomfort. To examine the incidence, location, and stage of pressure ulcers and patients' comfort with a nasal-oral mask compared with a full-face mask. A before-after study of a convenience sample of patients with noninvasive ventilation orders in 5 intensive care units was conducted. Two groups of 100 patients each received either the nasal-oral mask or the full-face mask. Skin was assessed before the mask was applied and every 12 hours after that or upon mask removal. Comfort levels were assessed every 12 hours on a Likert scale of 1 to 5 (1, most comfortable). A pressure ulcer developed in 20% of patients in the nasal-oral mask group and 2% of patients in the full-face mask group (P face mask (mean [SD], 1.9 [1.1]) than with the nasal-oral mask (mean [SD], 2.7 [1.2], P face mask and 25 (SD, 20.7) and 92% for nasal-oral mask. No patients who had a pressure ulcer develop with the nasal-oral mask had a pressure ulcer develop with the full-face mask. The full-face mask resulted in significantly fewer pressure ulcers and was more comfortable for patients. The full-face mask is a reasonable alternative to traditional nasal-oral masks for patients receiving noninvasive ventilation. ©2015 American Association of Critical-Care Nurses.

  15. Comparing the Efficacy of Face Mask CPAP with Nasopharyngeal CPAP for Neonatal Transport after Delivery

    Directory of Open Access Journals (Sweden)

    Manizheh Mostafa-Gharehbaghi

    2013-09-01

    Full Text Available Background: Preterm infants have respiratory failure and complications because surfactant in alveolus is low. CPAP (Continuous positive airway pressure is a method for respiratory support in pre-term neonates and is provided by different equipment and methods. This study aims to compare two different routes of CPAP delivery in preterm newborn infants and to determine the need for surfactant replacement therapy in two groups. Materials and Methods: This is a randomized controlled clinical trial. Eighty four preterm infants delivered in Al-Zahra Hospital with gestational age 28-32 weeks were enrolled in this study from January 2012 to September 2012. They were randomly allocated in two groups. After initial stabilization in delivery room, forty two infants transferred to neonatal intensive care unit (NICU with face mask CPAP and 42 infant with nasopharyngeal CPAP and continued nasal CPAP in the NICU in both groups. All infants were followed for developing respiratory distress and need for surfactant replacement therapy and oxygen dependency till discharge.Results: The neonates that treated with two methods of CPAP delivery were similar with respect to gestation age, birth weight and other demographic characteristics. Twenty three neonates (65.5% in face mask group and 15 neonates (39.5% in nasopharyngeal CPAP group need surfactant replacement therapy (p=0.08.Conclusion: Mask CPAP or nasopharyngeal CPAP can used in preterm infants after delivery for neonatal transfer to NICU. This study showed no method of CPAP delivery is preferable to other in decreasing the need for surfactant therapy.

  16. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.; Moti, S.

    1984-01-01

    This invention provides an improved device for shielding and protecting a person against direct and scattered x-ray radiation to the face, head and neck to be worn on the shoulders. The device includes a radiation-shielding face mask having a lead-filled frame and a lead-containing transparent radiation-shielding lens mounted in the frame. The frame is supported upon the shoulders. A first portion of the frame extends generally inward below the chin of the person, and a second portion of the frame extends generally vertically from an inward portion of the first portion and generally rearwardly adjacent to at least one lateral side of the neck of the person

  17. A survey of Alberta physicians' use of and attitudes toward face masks and face shields in the operating room setting.

    Science.gov (United States)

    Davis, Philip J; Spady, Donald; Forgie, Sarah E D

    2007-09-01

    There is little evidence that surgical mask use by physicians in the operating room (OR) reduces surgical site infections (SSIs), but masks do protect the wearer from potentially infectious splashes. Face shields offer even more protection because they cover the eyes, but they may be perceived as offering less protection to the patient than do masks. The objectives of this study were to ascertain if there were predictors to determine which OR physicians are continuing to use masks and what their reasons are for doing so, and which OR physicians would accept face shields and their reasons for doing so. We surveyed the province of Alberta's surgeons, general practice (GP) surgeons, anesthesiologists, and GP anesthetists to determine how many physicians in the OR wear surgical masks, their reasons for wearing surgical masks (ethical, legal, protection of the patient, protection of the wearer), and if they believe that face shields offer more protection to the patient or to the wearer. We also sought to examine which demographic factors affected their responses. The data were examined with chi(2) analysis to assess the relationships of age and practitioner type, and for various outcome variables. A significance level of P masks; masks are worn to prevent the spread of disease, not because it is tradition to do so; masks protect the wearer more than do face shields; and wearing face shields alone will subject the patient to higher rates of SSIs. Surgeons are more likely than are anesthesiologists to wear surgical masks in the OR and wear a surgical mask and a face shield if the patient has risk factors for a blood borne infection. According to our survey, age and profession were the most important variables that affected the potential use of surgical masks and face shields. Younger OR physicians likely would be amenable to using face shields in addition to masks in the OR to protect themselves from exposure to blood or bodily fluids.

  18. Cost Analysis of Noninvasive Helmet Ventilation Compared with Use of Noninvasive Face Mask in ARDS

    Directory of Open Access Journals (Sweden)

    Kwadwo Kyeremanteng

    2018-01-01

    Full Text Available Intensive care unit (ICU costs have doubled since 2000, totalling 108 billion dollars per year. Acute respiratory distress syndrome (ARDS has a prevalence of 10.4% and a 28-day mortality of 34.8%. Noninvasive ventilation (NIV is used in up to 30% of cases. A recent randomized controlled trial by Patel et al. (2016 showed lower intubation rates and 90-day mortality when comparing helmet to face mask NIV in ARDS. The population in the Patel et al. trial was used for cost analysis in this study. Projections of cost savings showed a decrease in ICU costs by $2527 and hospital costs by $3103 per patient, along with a 43.3% absolute reduction in intubation rates. Sensitivity analysis showed consistent cost reductions. Projected annual cost savings, assuming the current prevalence of ARDS, were $237538 in ICU costs and $291682 in hospital costs. At a national level, using yearly incidence of ARDS cases in American ICUs, this represents $449 million in savings. Helmet NIV, compared to face mask NIV, in nonintubated patients with ARDS, reduces ICU and hospital direct-variable costs along with intubation rates, LOS, and mortality. A large-scale cost-effectiveness analysis is needed to validate the findings.

  19. Evaluation of protection provided by air purifying half and full-face masks as worn

    International Nuclear Information System (INIS)

    Murata, Mikio; Ikezawa, Yoshio; Yoshida, Yoshikazu

    1979-01-01

    For selecting good-performing masks and estimating the protection provided by the masks, the leakage has been measured for six types of half mask and three types of full-face mask as worn. The cloud of submicron sodium chloride particles was generated within a test hood in which the subject wore his mask. The air sampled from inside the mask with a miniature pump was assessed by a flame photometer. The leakage was measured under four simulated working conditions such as normal breathing, smiling, moving head, and talking. The measured protection factors (defined as the ratio of the concentration of the test cloud outside the mask to that inside the mask) widely distributed from 10 to 3,300 for the half masks and from 100 to 3,300 for the full-face masks, depending on the persons and the working conditions. The values characterising the distribution of the protection factor for each mask are summarized. Based on these values, the performance of each mask and the effects of working conditions on the protection are discussed. (author)

  20. Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

    Science.gov (United States)

    Bugis, Alaa A; Sheard, Meryl M; Fink, James B; Harwood, Robert J; Ari, Arzu

    2015-09-01

    The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. Albuterol (2.5 mg/3 mL) was administered to an in vitro model consisting of an adult teaching mannequin extrathoracic and upper airway with stoma intubated with an 8-mm fenestrated tracheostomy tube. The cuff was deflated. A collecting filter at the level of the bronchi was connected to a breathing simulator at a tidal volume of 400 mL, breathing frequency of 20 breaths/min, and I:E of 2:1 and 1:2. A jet nebulizer was operated with O2 at 8 L/min. Each interface was tested in triplicate. The flow was discontinued at the end of nebulization. For each test, the nebulizer was attached to a tracheostomy collar with the fenestration open or closed, a Wright mask, or an aerosol mask. Drug was analyzed by spectrophotometry (276 nm). A paired t test and analysis of variance were performed (P mask (4.1 ± 0.6%) and aerosol mask (3.5 ± 0.04%) were both less than with the tracheostomy collar under either condition (P mask (7.2 ± 0.6%), and aerosol mask (6.1 ± 0.5%). In an adult tracheostomy model, the tracheostomy collar delivered more aerosol to the bronchi than the Wright or aerosol mask. An I:E of 2:1 caused greater aerosol deposition compared with an I:E of 1:2. During aerosol administration via a tracheostomy collar, closing the fenestration improved aerosol delivery. Copyright © 2015 by Daedalus Enterprises.

  1. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    Science.gov (United States)

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Surgical Face Masks Worn by Patients with Multidrug-Resistant Tuberculosis

    Science.gov (United States)

    Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A.; van der Walt, Martie; Nardell, Edward A.

    2012-01-01

    Rationale: Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. Objectives: We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Methods: Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Measurements and Main Results: Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68–85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31–51%), representing a 56% (95% CI, 33–70.5%) decreased risk of TB transmission when patients used masks. Conclusions: Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients. PMID:22323300

  3. Hyper-realistic face masks: a new challenge in person identification.

    Science.gov (United States)

    Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob

    2017-01-01

    We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.

  4. Noninvasive CPAP with face mask: comparison among new air-entrainment masks and the Boussignac valve.

    Science.gov (United States)

    Mistraletti, Giovanni; Giacomini, Matteo; Sabbatini, Giovanni; Pinciroli, Riccardo; Mantovani, Elena S; Umbrello, Michele; Palmisano, Debora; Formenti, Paolo; Destrebecq, Anne L L; Iapichino, Gaetano

    2013-02-01

    The performances of 2 noninvasive CPAP systems (high flow and low flow air-entrainment masks) were compared to the Boussignac valve in 3 different scenarios. Scenario 1: pneumatic lung simulator with a tachypnea pattern (tidal volume 800 mL at 40 breaths/min). Scenario 2: Ten healthy subjects studied during tidal breaths and tachypnea. Scenario 3: Twenty ICU subjects enrolled for a noninvasive CPAP session. Differences between set and effective CPAP level and F(IO(2)), as well as the lowest airway pressure and the pressure swing around the imposed CPAP level, were analyzed. The lowest airway pressure and swing were correlated to the pressure-time product (area of the airway pressure curve below the CPAP level) measured with the simulator. P(aO(2)) was a subject's further performance index. Lung simulator: Boussignac F(IO(2)) was 0.54, even if supplied with pure oxygen. The air-entrainment masks had higher swing than the Boussignac (P = .007). Pressure-time product correlated better with pressure swing (Spearman correlation coefficient [ρ] = 0.97) than with lowest airway pressure (ρ = 0.92). In healthy subjects, the high-flow air-entrainment mask showed lower difference between set and effective F(IO(2)) (P mask had lower swing than the Boussignac valve (P = .03) with similar P(aO(2)) increase. High-flow air-entrainment mask showed the best performance in human subjects. During high flow demand, the Boussignac valve delivered lower than expected F(IO(2)) and showed higher dynamic hyper-pressurization than the air-entrainment masks. © 2013 Daedalus Enterprises.

  5. Voice-associated static face image releases speech from informational masking.

    Science.gov (United States)

    Gao, Yayue; Cao, Shuyang; Qu, Tianshu; Wu, Xihong; Li, Haifeng; Zhang, Jinsheng; Li, Liang

    2014-06-01

    In noisy, multipeople talking environments such as a cocktail party, listeners can use various perceptual and/or cognitive cues to improve recognition of target speech against masking, particularly informational masking. Previous studies have shown that temporally prepresented voice cues (voice primes) improve recognition of target speech against speech masking but not noise masking. This study investigated whether static face image primes that have become target-voice associated (i.e., facial images linked through associative learning with voices reciting the target speech) can be used by listeners to unmask speech. The results showed that in 32 normal-hearing younger adults, temporally prepresenting a voice-priming sentence with the same voice reciting the target sentence significantly improved the recognition of target speech that was masked by irrelevant two-talker speech. When a person's face photograph image became associated with the voice reciting the target speech by learning, temporally prepresenting the target-voice-associated face image significantly improved recognition of target speech against speech masking, particularly for the last two keywords in the target sentence. Moreover, speech-recognition performance under the voice-priming condition was significantly correlated to that under the face-priming condition. The results suggest that learned facial information on talker identity plays an important role in identifying the target-talker's voice and facilitating selective attention to the target-speech stream against the masking-speech stream. © 2014 The Institute of Psychology, Chinese Academy of Sciences and Wiley Publishing Asia Pty Ltd.

  6. The extended functional neuroanatomy of emotional processing biases for masked faces in major depressive disorder.

    Directory of Open Access Journals (Sweden)

    Teresa A Victor

    Full Text Available Major depressive disorder (MDD is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however.To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants.Unmedicated-depressed participants with MDD (n=22 and healthy controls (HC; n=25 underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups.The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex.Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.

  7. The extended functional neuroanatomy of emotional processing biases for masked faces in major depressive disorder.

    Science.gov (United States)

    Victor, Teresa A; Furey, Maura L; Fromm, Stephen J; Bellgowan, Patrick S F; Öhman, Arne; Drevets, Wayne C

    2012-01-01

    Major depressive disorder (MDD) is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however. To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants. Unmedicated-depressed participants with MDD (n=22) and healthy controls (HC; n=25) underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD) signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups. The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex. Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.

  8. Universal Mask Usage for Reduction of Respiratory Viral Infections After Stem Cell Transplant: A Prospective Trial.

    Science.gov (United States)

    Sung, Anthony D; Sung, Julia A M; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J; Horwitz, Mitchell E

    2016-10-15

    Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010-2014) compared with the premask period (2003-2009). RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P mask group compared with the premask group (0.19-0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  9. Sandwich masking eliminates both visual awareness of faces and face-specific brain activity through a feedforward mechanism.

    Science.gov (United States)

    Harris, Joseph A; Wu, Chien-Te; Woldorff, Marty G

    2011-06-07

    It is generally agreed that considerable amounts of low-level sensory processing of visual stimuli can occur without conscious awareness. On the other hand, the degree of higher level visual processing that occurs in the absence of awareness is as yet unclear. Here, event-related potential (ERP) measures of brain activity were recorded during a sandwich-masking paradigm, a commonly used approach for attenuating conscious awareness of visual stimulus content. In particular, the present study used a combination of ERP activation contrasts to track both early sensory-processing ERP components and face-specific N170 ERP activations, in trials with versus without awareness. The electrophysiological measures revealed that the sandwich masking abolished the early face-specific N170 neural response (peaking at ~170 ms post-stimulus), an effect that paralleled the abolition of awareness of face versus non-face image content. Furthermore, however, the masking appeared to render a strong attenuation of earlier feedforward visual sensory-processing signals. This early attenuation presumably resulted in insufficient information being fed into the higher level visual system pathways specific to object category processing, thus leading to unawareness of the visual object content. These results support a coupling of visual awareness and neural indices of face processing, while also demonstrating an early low-level mechanism of interference in sandwich masking.

  10. Use of face masks by non-scrubbed operating room staff: a randomized controlled trial.

    Science.gov (United States)

    Webster, Joan; Croger, Sarah; Lister, Carolyn; Doidge, Michelle; Terry, Michael J; Jones, Ian

    2010-03-01

    Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections (SSIs) when non-scrubbed operating room staff did not wear surgical face masks. Eight hundred twenty-seven participants undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital were enrolled. Complete follow-up data were available for 811 patients (98.1%). Operating room lists were randomly allocated to a 'Mask group' (all non-scrubbed staff wore a mask) or 'No Mask group' (none of the non-scrubbed staff wore masks). The primary end point, SSI was identified using in-patient surveillance; post discharge follow-up and chart reviews. The patient was followed for up to six weeks. Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.

  11. Disposable surgical face masks for preventing surgical wound infection in clean surgery

    Directory of Open Access Journals (Sweden)

    Allyson Lipp

    Full Text Available BACKGROUND: Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. OBJECTIVES: To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. SEARCH METHODS: We searched The Cochrane Wounds Group Specialised Register (searched 14 September 2011; The Cochrane Central Register of Controlled Trials (CENTRAL (The Cochrane Library 2011, Issue 3; Ovid MEDLINE (2008 to August Week 5 2011; Ovid MEDLINE (In-Process &Other Non-Indexed Citations September 13, 2011; Ovid EMBASE (2008 to 2011 Week 35; and EBSCO CINAHL (2008 to 9 September 2011. SELECTION CRITERIA: Randomized controlled trials (RCTs and quasi-randomized controlled trials comparing the use of disposable surgical masks with the use of no mask. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently. MAIN RESULTS: Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. AUTHORS' CONCLUSIONS: From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  12. Review of economic evaluations of mask and respirator use for protection against respiratory infection transmission.

    Science.gov (United States)

    Mukerji, Shohini; MacIntyre, C Raina; Newall, Anthony T

    2015-10-13

    There has been increasing debate surrounding mask and respirator interventions to control respiratory infection transmission in both healthcare and community settings. As decision makers are considering the recommendations they should evaluate how to provide the most efficient protection strategies with minimum costs. The aim of this review is to identify and evaluate the existing economic evaluation literature in this area and to offer advice on how future evaluations on this topic should be conducted. We searched the Scopus database for all literature on economic evaluation of mask or respirator use to control respiratory infection transmission. Reference lists from the identified studies were also manually searched. Seven studies met our inclusion criteria from the initial 806 studies identified by the search strategy and our manual search. Five studies considered interventions for seasonal and/or pandemic influenza, with one also considering SARS (Severe Acute Respiratory Syndrome). The other two studies focussed on tuberculosis transmission control interventions. The settings and methodologies of the studies varied greatly. No low-middle income settings were identified. Only one of the reviewed studies cited clinical evidence to inform their mask/respirator intervention effectiveness parameters. Mask and respirator interventions were generally reported by the study authors to be cost saving or cost-effective when compared to no intervention or other control measures, however the evaluations had important limitations. Given the large cost differential between masks and respirators, there is a need for more comprehensive economic evaluations to compare the relative costs and benefits of these interventions in situations and settings where alternative options are potentially applicable. There are at present insufficient well conducted cost-effectiveness studies to inform decision-makers on the value for money of alternative mask/respirator options.

  13. Combined tool approach is 100% successful for emergency football face mask removal.

    Science.gov (United States)

    Copeland, Aaron J; Decoster, Laura C; Swartz, Erik E; Gattie, Eric R; Gale, Stephanie D

    2007-11-01

    To compare effectiveness of two techniques for removing football face masks: cutting loop straps [cutting tool: FMXtractor (FMX)] or removing screws with a cordless screwdriver and using the FMXtractor as needed for failed removals [combined tool (CT)]. Null hypotheses: no differences in face mask removal success, removal time or difficulty between techniques or helmet characteristics. Retrospective, cross-sectional. NOCSAE-certified helmet reconditioning plants. 600 used high school helmets. Face mask removal attempted with two techniques. Success, removal time, rating of perceived exertion (RPE). Both techniques were effective [CT 100% (300/300); FMX 99.4% (298/300)]. Use of the backup FMXtractor in CT trials was required in 19% of trials. There was significantly (Pfootball player's helmet.

  14. Thin-plate Spline Analysis of the Effects of Face Mask Treatment in Children with Maxillary Retrognathism

    OpenAIRE

    Jenny Zwei-Chieng Chang; Yi-Jane Chen; Jane Chung-Chen Yao; Frank Hsin-Fu Chang

    2006-01-01

    Face mask therapy is indicated for growing patients who suffer from maxillary retrognathia. Most previous studies used conventional cephalometric analysis to evaluate the effects of face mask treatment. Cephalometric analysis has been shown to be insufficient for complex craniofacial configurations. The purpose of this study was to investigate changes in the craniofacial structure of children with maxillary retrognathism following face mask treatment by means of thin-plate spline analysis. ...

  15. Interactions between concentric form-from-structure and face perception revealed by visual masking but not adaptation

    Science.gov (United States)

    Feczko, Eric; Shulman, Gordon L.; Petersen, Steven E.; Pruett, John R.

    2014-01-01

    Findings from diverse subfields of vision research suggest a potential link between high-level aspects of face perception and concentric form-from-structure perception. To explore this relationship, typical adults performed two adaptation experiments and two masking experiments to test whether concentric, but not nonconcentric, Glass patterns (a type of form-from-structure stimulus) utilize a processing mechanism shared by face perception. For the adaptation experiments, subjects were presented with an adaptor for 5 or 20 s, prior to discriminating a target. In the masking experiments, subjects saw a mask, then a target, and then a second mask. Measures of discriminability and bias were derived and repeated measures analysis of variance tested for pattern-specific masking and adaptation effects. Results from Experiment 1 show no Glass pattern-specific effect of adaptation to faces; results from Experiment 2 show concentric Glass pattern masking, but not adaptation, may impair upright/inverted face discrimination; results from Experiment 3 show concentric and radial Glass pattern masking impaired subsequent upright/inverted face discrimination more than translational Glass pattern masking; and results from Experiment 4 show concentric and radial Glass pattern masking impaired subsequent face gender discrimination more than translational Glass pattern masking. Taken together, these findings demonstrate interactions between concentric form-from-structure and face processing, suggesting a possible common processing pathway. PMID:24563526

  16. Fabrication technique for a custom face mask for the treatment of obstructive sleep apnea.

    Science.gov (United States)

    Prehn, Ronald S; Colquitt, Tom

    2016-05-01

    The development of the positive airway pressure custom mask (TAP-PAP CM) has changed the treatment of obstructive sleep apnea. The TAP-PAP CM is used in continuous positive airway pressure therapy (CPAP) and is fabricated from the impression of the face. This mask is then connected to a post screwed into the mechanism of the TAP3 (Thornton Anterior Positioner) oral appliance. This strapless CPAP face mask features an efficient and stable CPAP interface with mandibular stabilization (Hybrid Therapy). A technique with a 2-stage polyvinyl siloxane face impression is described that offers improvements over the established single-stage face impression. This 2-stage impression technique eliminates problems inherent in the single-stage face impression, including voids, compressed tissue, inadequate borders, and a rushed experience due to the setting time of the single stage. The result is a custom mask with an improved seal to the CPAP device. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis

    Science.gov (United States)

    Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.

    2016-01-01

    Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions

  18. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis.

    Science.gov (United States)

    Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E

    2016-05-17

    Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95

  19. Marquardt's Phi mask: pitfalls of relying on fashion models and the golden ratio to describe a beautiful face.

    Science.gov (United States)

    Holland, E

    2008-03-01

    Stephen Marquardt has derived a mask from the golden ratio that he claims represents the "ideal" facial archetype. Many have found his mask convincing, including cosmetic surgeons. However, Marquardt's mask is associated with numerous problems. The method used to examine goodness of fit with the proportions in the mask is faulty. The mask is ill-suited for non-European populations, especially sub-Saharan Africans and East Asians. The mask also appears to approximate the face shape of masculinized European women. Given that the general public strongly and overwhelmingly prefers above average facial femininity in women, white women seeking aesthetic facial surgery would be ill-advised to aim toward a better fit with Marquardt's mask. This article aims to show the proper way of assessing goodness of fit with Marquardt's mask, to address the shape of the mask as it pertains to masculinity-femininity, and to discuss the broader issue of an objective assessment of facial attractiveness. Generalized Procrustes analysis is used to show how goodness of fit with Marquardt's mask can be assessed. Thin-plate spline analysis is used to illustrate visually how sample faces, including northwestern European averages, differ from Marquardt's mask. Marquardt's mask best describes the facial proportions of masculinized white women as seen in fashion models. Marquardt's mask does not appear to describe "ideal" face shape even for white women because its proportions are inconsistent with the optimal preferences of most people, especially with regard to femininity.

  20. [Respiratory distress in three newborns after mask disinfection with Endosporine. Probable role of glutaraldehyde].

    Science.gov (United States)

    Testud, F; Bubnic, A; Valancogne, A; Assaf, G; Vray, C; Cottin, X; Bourgeois, J; Descotes, J

    2000-05-01

    Disinfectants for medical devices are uncommonly a cause of iatrogenic adverse effects. Nevertheless, when misused, they can induce severe complications. Three cases of acute respiratory distress in newborns probably induced by glutaraldehyde are reported. Three children born by Caesarean section between 8 and 19 May 1999 in the same hospital presented acute respiratory distress requiring hospitalization in the neonatal intensive care unit; one child was premature. The clinical appearance, which was initially normal, deteriorated with a respiratory distress in 30 to 60 minutes. Recovery was uneventful in all cases. The diagnosis considered was a hyaline membrane disease. The enquiry conducted after this cluster onset identified, as a main contributing factor, the disinfection procedure recently introduced in the surgical theater. Review of toxicologic data on glutaraldehyde shows this is a highly irritating chemical for the respiratory tract, even at low concentrations. Clinical and radiologic features in these three neonates are compatible with a pulmonary sub-edema on an immature alveolar setting. The hypothesis proposed is that glutaraldehyde, the active ingredient of the biocidal formula used to disinfect the respiratory masks, was massively desorbed from the rubber and foam of which masks are made.

  1. Effect of facial material softness and applied force on face mask dead volume, face mask seal, and inhaled corticosteroid delivery through an idealized infant replica.

    Science.gov (United States)

    Carrigy, Nicholas B; O'Reilly, Connor; Schmitt, James; Noga, Michelle; Finlay, Warren H

    2014-08-01

    During the aerosol delivery device design and optimization process, in vitro lung dose (LD) measurements are often performed using soft face models, which may provide a more clinically relevant representation of face mask dead volume (MDV) and face mask seal (FMS) than hard face models. However, a comparison of MDV, FMS, and LD for hard and soft face models is lacking. Metal, silicone, and polyurethane represented hard, soft, and very soft facial materials, respectively. MDV was measured using a water displacement technique. FMS was measured using a valved holding chamber (VHC) flow rate technique. The LD of beclomethasone dipropionate (BDP) delivered via a 100-μg Qvar® pressurized metered dose inhaler with AeroChamber Plus® Flow-Vu® VHC and Small Mask, defined as that which passes through the nasal airways of the idealized infant geometry, was measured using a bias tidal flow system with a filter. MDV, FMS, and LD were measured at 1.5 lb and 3.5 lb of applied force. A mathematical model was used to predict LD based on experimental measurements of MDV and FMS. Experimental BDP LD measurements for ABS, silicone, and polyurethane at 1.5 lb were 0.9 (0.6) μg, 2.4 (1.9) μg, and 19.3 (0.9) μg, respectively. At 3.5 lb, the respective LD was 10.0 (1.5) μg, 13.8 (1.4) μg, and 14.2 (0.9) μg. Parametric analysis with the mathematical model showed that differences in FMS between face models had a greater impact on LD than differences in MDV. The use of soft face models resulted in higher LD than hard face models, with a greater difference at 1.5 lb than at 3.5 lb. A lack of a FMS led to decreased dose consistency; therefore, a sealant should be used when measuring LD with a hard ABS or soft silicone face model at 1.5 lb of applied force or less.

  2. Face mask sampling for the detection of Mycobacterium tuberculosis in expelled aerosols.

    Science.gov (United States)

    Williams, Caroline M L; Cheah, Eddy S G; Malkin, Joanne; Patel, Hemu; Otu, Jacob; Mlaga, Kodjovi; Sutherland, Jayne S; Antonio, Martin; Perera, Nelun; Woltmann, Gerrit; Haldar, Pranabashis; Garton, Natalie J; Barer, Michael R

    2014-01-01

    Although tuberculosis is transmitted by the airborne route, direct information on the natural output of bacilli into air by source cases is very limited. We sought to address this through sampling of expelled aerosols in face masks that were subsequently analyzed for mycobacterial contamination. In series 1, 17 smear microscopy positive patients wore standard surgical face masks once or twice for periods between 10 minutes and 5 hours; mycobacterial contamination was detected using a bacteriophage assay. In series 2, 19 patients with suspected tuberculosis were studied in Leicester UK and 10 patients with at least one positive smear were studied in The Gambia. These subjects wore one FFP30 mask modified to contain a gelatin filter for one hour; this was subsequently analyzed by the Xpert MTB/RIF system. In series 1, the bacteriophage assay detected live mycobacteria in 11/17 patients with wearing times between 10 and 120 minutes. Variation was seen in mask positivity and the level of contamination detected in multiple samples from the same patient. Two patients had non-tuberculous mycobacterial infections. In series 2, 13/20 patients with pulmonary tuberculosis produced positive masks and 0/9 patients with extrapulmonary or non-tuberculous diagnoses were mask positive. Overall, 65% of patients with confirmed pulmonary mycobacterial infection gave positive masks and this included 3/6 patients who received diagnostic bronchoalveolar lavages. Mask sampling provides a simple means of assessing mycobacterial output in non-sputum expectorant. The approach shows potential for application to the study of airborne transmission and to diagnosis.

  3. Use of Respiratory Mask and Influencing Factors among Workers Who Worked in Welding Department at Automotive Sector

    Directory of Open Access Journals (Sweden)

    Melek Nihal Esin,A. Dilek Yilmaz

    2012-06-01

    Full Text Available AIM: This study was designed in a cross sectional pattern in order to determine workers’ behaviors about respiratory mask use and the factors involved. METHOD: The study was conducted with 100 workers in the welding department of a factory operating in automotive sector and employing approximately 1000 people. The data in the study was collected by means of ‘Form for the Assessment of Descriptive Features of Employees’ and ‘Respiratory Mask Use Behaviors Form”, developed by the researchers; the Multidimensional Health Locus of Control Scale, developed by Wallston and De Wellis; Self-Actualization Scale and Health Responsibility Scale, developed by Walker, Sechrist and Pender. RESULTS: It was found out that a majority of the workers are aged between 26 and 33 (32%, 76% of them are married, 37% are primary school graduates and 58% of them have been working for more than 11 years. It was also determined that 60% of the workers regularly wear respiratory mask. 14% of those using masks irregularly stated that they “used a respiratory mask for a short time” and 26% of them stated that they “never wore a respiratory mask”. The findings from the study showed that factors like the physical formation of the respiratory mask, the level of information about the mask, and the cognitive perceptual factors related to the employee’s health influenced respiratory mask use. Two variables with significant odds ratios were identified thorough logistic regression analysis. Worker who reported that they had inability to breathe when wearing a mask were over 9 times (OR= 9,48, %95 CI= 1,86- 16,52 and “the time spent putting on and removing a mask” were over 4 times (OR= 4,85, %95 CI= 0,03-8,81 more likely to have never wear a respiratory mask than those who used regularly wear mask . CONCLUSION: It is considered that the results from this study could form a set of basic data for “respiratory mask use improvement programs” to be designed by

  4. Face-masks for facial atopic eczema: consider a hydrocolloid dressing.

    Science.gov (United States)

    Rademaker, Marius

    2013-08-01

    Facial involvement of atopic eczema in young children can be difficult to manage. Chronic scratching and rubbing, combined with parental reluctance to use topical corticosteroids on the face, often results in recalcitrant facial eczema. While wet wraps are a useful management option for moderate/severe atopic eczema involving the trunk and limbs they are difficult to use on the face. We describe the use of a face-mask using a widely available adhesive hydrocolloid dressing (DuoDerm extra thin) in three children with recalcitrant facial atopic eczema. Symptomatic control of itch or soreness was obtained within hours and the facial atopic eczema was markedly improved by 7 days. The face-masks were easy to apply, each lasting 1-4 days. One patient had a single adjuvant application of a potent topical corticosteroid under the hydrocolloid dressing. All three patients had long remissions (greater than 3 months) of their facial eczema, although all continued to have significant eczema involving their trunk and limbs. Face-masks made from hydrocolloid dressings, with or without topical corticosteroids, are worth considering in children with recalcitrant facial eczema. © 2012 The Author. Australasian Journal of Dermatology © 2012 The Australasian College of Dermatologists.

  5. Suicidal nitrogen inhalation by use of scuba full-face diving mask.

    Science.gov (United States)

    Straka, Lubomir; Novomesky, Frantisek; Gavel, Anton; Mlynar, Juraj; Hejna, Petr

    2013-09-01

    A 29-year-old man was found dead lying on the bed in a hotel room in a famous Slovak mountain resort. He had a full-face diving mask on his face, connected through a diving breath regulator to a valve of an industrial (nondiving) high-pressure tank containing pure 100% nitrogen. The breath regulator (open-circuit type) used allowed inhalation of nitrogen without addition of open air, and the full-face diving mask assured aspiration of the gas even during the time of unconsciousness. At autopsy, we found the typical signs of suffocation. Toxicological analysis revealed 94.7% content of nitrogen in alveolar air. Following the completion of the police investigation, the manner of death was classified as a suicide. Within the medico-legal literature, there has been only one similar case of suicidal nitrogen inhalation described. © 2013 American Academy of Forensic Sciences.

  6. Experiences in the utilization of face masks for radiotherapy of tumors of the head and neck

    International Nuclear Information System (INIS)

    Niewald, M.; Lehmann, W.; Uhlmann, U.; Berberich, W.; Scharding, B.; Dietz, R.; Schnabel, K.; Leetz, K.H.; Universitaet des Saarlandes, Homburg/Saar

    1985-01-01

    By means of positioning and fixation aids, the precision and reproducibility of irradiation fields in radiotherapy of malignant tumors of the head and neck can be considerably improved. Face masks made of different synthetic materials have proved to be a practicable solution of this problem. In our hospital we have developed and tested a simple and not expensive possibility of manufacturing the maks with ''Baycast'' (producer: Bayer AG Leverkusen). The material is generally well tolerated by the patients, and the head is sufficiently fixed. An increased incidence of radiogenic dermatitides is caused by the overlapping of the depth dose of the Co-60 gamma radiation due to additional secondary electrons emanating from the mask material. This effect can be partly prevented by cutting out the irradiation fields in the masks. (orig.) [de

  7. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    Science.gov (United States)

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; Pcadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  8. A Novel system for the production of immobilisation face masks for radiotherapy

    International Nuclear Information System (INIS)

    Deans, T.; McKernan, B.

    2004-01-01

    Full text: Patient immobilisation is critically important for the radiation treatment of Head and Neck cancers. Immobilisation masks can be made from either thermoplastics or vacuumed polycarbonate taken from a plaster 'positive' mould. To create the positive mould, our Radiation Oncology Department has traditionally used Plaster of Paris impressions. This process is time consuming, messy and stressful for the patient. This presentation describes an alternative method for the creation of the positive mould which was developed at this hospital, which is much quicker than previous methods and which obviates all stress to the patient. The patient's face is scanned in the Department of Radiation Oncology using one of a new generation of lightweight, hand-held, laser surface scanners. This process takes a few seconds. The digital information captured by the scanner characterising the patient's face is then emailed to the Department of Medical Technology and Physics (MTP), where a software package is used to manipulate the information into a form suitable for use as input to a Computerised Numerical Control Vertical Machining Centre (CNC-VMC). The CNC-VMC then automatically mills a mould of the patient's face from a block of machineable Plaster of Paris. Two mechanical technicians have undergone specialised training in the manipulation of the data supplied by the scanner into the CNC-VMC format. Proof of principle of this method was established nearly four years ago, with the first patient face mould being produced in February 2004. Since that time more than 100 moulds for face masks have been produced. Typically moulds are delivered to Radiation Oncology within ninety minutes of an email containing patient face data being received in MTP. Approximately half of this time is used for the manipulation of the data provided, while the remaining time is used for the actual automated milling of the mould. This compares with an average time of in excess of 40 hours for

  9. Face masks in radiotherapy of head and neck cancers: Comparative test of different materials

    International Nuclear Information System (INIS)

    Niewald, M.; Lehmann, W.; Scharding, B.; Berberich, W.; Schnabel, K.; Leetz, H.K.; Universitaet des Saarlandes, Homburg/Saar

    1986-01-01

    A most precise immobilisation of the patient's head is indispensabel in order to reach a high degree of exactness and reproducibility in radiotherapy of malignant head and neck tumors. Face masks made of different synthetic materials have proved to be a simple and economical solution for this problem. Based on our own experiences with ''Baycast Longuettes'' (manufacturing firm: Johnson and Johnson, Duesseldorf), eleven substances have been tested in the phantom (compound of plaster and synthetic resin, thermoplast, polyurethane foam, compounds of cotton and synthetic resin and fibre glass compounds). An appropriate material was ''Hexcelite'' (manufacturing firm: Medimex, Hamburg), a reticulated thermoplast which after warming up can be easily adapted to the patient's face and which guarantees a very good fixation of the head. As compared to solid masks, there is only a slight superposition of the depth dose of Co-60 gamma radiation by secondary electrons from the mask material. So that an increased rate of radiogenic dermatitides is not to be expected. (orig.) [de

  10. Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward.

    Science.gov (United States)

    Dharmadhikari, Ashwin S; Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A; van der Walt, Martie; Nardell, Edward A

    2012-05-15

    Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68-85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31-51%), representing a 56% (95% CI, 33-70.5%) decreased risk of TB transmission when patients used masks. Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients.

  11. PENGGUNAAN FACE-MASK & EKSPANSI PALATAL PADA PERAWATAN MALOKLUSI KLAS III (Studi Pustaka

    Directory of Open Access Journals (Sweden)

    Krisnawati Krisnawati

    2015-08-01

    Full Text Available Class III skeletal anomaly is one of the most difficult malocclusions to correct in orthodontics. Orthodontist usually involved chincup appliances to restrain mandibular growth, camouflage techniques to advances maxillary incisors and retract mandibular incisors or waiting untul growth ceased to pursue orthognathic surgery. Many studies found that most of Class III malocclusions were characterized by maxillary retrognathism. In the late 1960s, the Delaire mask was popularized to protract the maxilla. The development of maxillary protraction with facemask and palatal expansion have provided a predictable and effective approach to managing treatment that was once considered difficult. Although no significant difference was found between early or late treatment group, the effect of improvement in facial aesthetics on psychosocial development resulted in a significant advantage for early treatment. However, the effects of face mask therapy should be evaluated over the long term in order to determine the relaps tendency.

  12. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  13. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.

    Science.gov (United States)

    Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S

    2010-03-01

    To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.

  14. Face Masks and Cough Etiquette Reduce the Cough Aerosol Concentration of Pseudomonas aeruginosa in People with Cystic Fibrosis.

    Science.gov (United States)

    Wood, Michelle E; Stockwell, Rebecca E; Johnson, Graham R; Ramsay, Kay A; Sherrard, Laura J; Jabbour, Nassib; Ballard, Emma; O'Rourke, Peter; Kidd, Timothy J; Wainwright, Claire E; Knibbs, Luke D; Sly, Peter D; Morawska, Lidia; Bell, Scott C

    2018-02-01

    People with cystic fibrosis (CF) generate Pseudomonas aeruginosa in droplet nuclei during coughing. The use of surgical masks has been recommended in healthcare settings to minimize pathogen transmission between patients with CF. To determine if face masks and cough etiquette reduce viable P. aeruginosa aerosolized during coughing. Twenty-five adults with CF and chronic P. aeruginosa infection were recruited. Participants performed six talking and coughing maneuvers, with or without face masks (surgical and N95) and hand covering the mouth when coughing (cough etiquette) in an aerosol-sampling device. An Andersen Cascade Impactor was used to sample the aerosol at 2 meters from each participant. Quantitative sputum and aerosol bacterial cultures were performed, and participants rated the mask comfort levels during the cough maneuvers. During uncovered coughing (reference maneuver), 19 of 25 (76%) participants produced aerosols containing P. aeruginosa, with a positive correlation found between sputum P. aeruginosa concentration (measured as cfu/ml) and aerosol P. aeruginosa colony-forming units. There was a reduction in aerosol P. aeruginosa load during coughing with a surgical mask, coughing with an N95 mask, and cough etiquette compared with uncovered coughing (P masks during coughing; yet, participants rated the surgical masks as more comfortable (P = 0.013). Cough etiquette provided approximately half the reduction of viable aerosols of the mask interventions during voluntary coughing. Talking was a low viable aerosol-producing activity. Face masks reduce cough-generated P. aeruginosa aerosols, with the surgical mask providing enhanced comfort. Cough etiquette was less effective at reducing viable aerosols.

  15. Superior recognition performance for happy masked and unmasked faces in both younger and older adults.

    Directory of Open Access Journals (Sweden)

    Joakim eSvard

    2012-11-01

    Full Text Available In the aging literature it has been shown that even though emotion recognition performance decreases with age, the decrease is less for happiness than other facial expressions. Studies in younger adults have also revealed that happy faces are more strongly attended to and better recognized than other emotional facial expressions. Thus, there might be a more age independent happy face advantage in facial expression recognition. By using a backward masking paradigm and varying stimulus onset asynchronies (17–267 ms the temporal development of a happy face advantage, on a continuum from low to high levels of visibility, was examined in younger and older adults. Results showed that across age groups, recognition performance for happy faces was better than for neutral and fearful faces at durations longer than 50 ms. Importantly, the results showed a happy face advantage already during early processing of emotional faces in both younger and older adults. This advantage is discussed in terms of processing of salient perceptual features and elaborative processing of the happy face. We also investigate the combined effect of age and neuroticism on emotional face processing. The rationale was previous findings of age related differences in physiological arousal to emotional pictures and a relation between arousal and neuroticism. Across all durations, there was an interaction between age and neuroticism, showing that being high in neuroticism might be disadvantageous for younger, but not older adults’ emotion recognition performance during arousal enhancing tasks. These results indicate that there is a relation between aging, neuroticism, and performance, potentially related to physiological arousal.

  16. Comparison of the effectiveness of high flow nasal oxygen cannula vs. standard non-rebreather oxygen face mask in post-extubation intensive care unit patients.

    Science.gov (United States)

    Brotfain, Evgeni; Zlotnik, Alexander; Schwartz, Andrei; Frenkel, Amit; Koyfman, Leonid; Gruenbaum, Shaun E; Klein, Moti

    2014-11-01

    Optimal oxygen supply is the cornerstone of the management of critically ill patients after extubation, especially in patients at high risk for extubation failure. In recent years, high flow oxygen system devices have offered an appropriate alternative to standard oxygen therapy devices such as conventional face masks and nasal prongs. To assess the clinical effects of high flow nasal cannula (HFNC) compared with standard oxygen face masks in Intensive Care Unit (ICU) patients after extubation. We retrospectively analyzed 67 consecutive ventilated critical care patients in the ICU over a period of 1 year. The patients were allocated to two treatment groups: HFNC (34 patients, group 1) and non-rebreathing oxygen face mask (NRB) (33 patients, group 2). Vital respiratory and hemodynamic parameters were assessed prior to extubation and 6 hours after extubation. The primary clinical outcomes measured were improvement in oxygenation, ventilation-free days, re-intubation, ICU length of stay, and mortality. The two groups demonstrated similar hemodynamic patterns before and after extubation. The respiratory rate was slightly elevated in both groups after extubation with no differences observed between groups. There were no statistically significant clinical differences in PaCO2. However, the use of HFNC resulted in improved PaO2/FiO2 post-extubation (P < 0.05). There were more ventilator-free days in the HFNC group (P< 0.05) and fewer patients required reintubation (1 vs. 6). There were no differences in ICU length of stay or mortality. This study demonstrated better oxygenation for patients treated with HFNC compared with NRB after extubation. HFNC may be more effective than standard oxygen supply devices for oxygenation in the post-extubation period.

  17. Thin-plate spline analysis of the effects of face mask treatment in children with maxillary retrognathism.

    Science.gov (United States)

    Chang, Jenny Zwei-Chieng; Liu, Pao-Hsin; Chen, Yi-Jane; Yao, Jane Chung-Chen; Chang, Hong-Po; Chang, Chih-Han; Chang, Frank Hsin-Fu

    2006-02-01

    Face mask therapy is indicated for growing patients who suffer from maxillary retrognathia. Most previous studies used conventional cephalometric analysis to evaluate the effects of face mask treatment. Cephalometric analysis has been shown to be insufficient for complex craniofacial configurations. The purpose of this study was to investigate changes in the craniofacial structure of children with maxillary retrognathism following face mask treatment by means of thin-plate spline analysis. Thirty children with skeletal Class III malocclusions who had been treated with face masks were compared with a group of 30 untreated gender-matched, age-matched, observation period-matched, and craniofacial configuration-matched subjects. Average geometries, scaled to an equivalent size, were generated by means of Procrustes analysis. Thin-plate spline analysis was then performed for localization of the shape changes. Face mask treatment induced a forward displacement of the maxilla, a counterclockwise rotation of the palatal plane, a horizontal compression of the anterior border of the symphysis and the condylar region, and a downward deformation of the menton. The cranial base exhibited a counterclockwise deformation as a whole. We conclude that thin-plate spline analysis is a valuable supplement to conventional cephalometric analysis.

  18. Face mask removal is safer than helmet removal for emergent airway access in American football.

    Science.gov (United States)

    Swartz, Erik E; Mihalik, Jason P; Beltz, Nora M; Day, Molly A; Decoster, Laura C

    2014-06-01

    In cases of possible cervical spine injury, medical professionals must be prepared to achieve rapid airway access while concurrently restricting cervical spine motion. Face mask removal (FMR), rather than helmet removal (HR), is recommended to achieve this. However, no studies have been reported that compare FMR directly with HR. The purpose of this study was to compare motion, time, and perceived difficulty in two commonly used American football helmets between FMR and HR techniques, and when helmet air bladders were deflated before HR compared with inflated scenarios. The study incorporated a repeated measures design and was performed in a controlled laboratory setting. Participants included 22 certified athletic trainers (15 men and seven women; mean age, 33.9±10.5 years; mean experience, 11.4±10.0 years; mean height, 172±9.4 cm; mean mass, 76.7±14.9 kg). All participants were free from upper extremity or central nervous system pathology for 6 months and provided informed consent. Dependent variables included head excursion in degrees (computed by subtracting the minimum position from the maximum position) in each of the three planes (sagittal, frontal, transverse), time to complete the required task, and ratings of perceived exertion. To address our study purposes, we used two-by-two repeated-measures analysis of variance (removal technique×helmet type, helmet type×deflation status) for each dependent variable. Independent variables consisted of removal technique (FMR and HR), helmet type (Riddell Revolution IQ [RIQ] and VSR4), and helmet deflation status (deflated [D], inflated, [I]). After familiarization, participants conducted two successful trials for each of six conditions in random order (RIQ-FMR, VSR4-FMR, RIQ-HR-D, VSR4-HR-D, RIQ-HR-I, and VSR4-HR-I). Face masks, helmets, and shoulder pads were removed from a live model wearing a properly fitted helmet and shoulder pads. The participant and an investigator stabilized the model's head. A six

  19. Cost-effectiveness analysis of N95 respirators and medical masks to protect healthcare workers in China from respiratory infections.

    Science.gov (United States)

    Mukerji, Shohini; MacIntyre, C Raina; Seale, Holly; Wang, Quanyi; Yang, Peng; Wang, Xiaoli; Newall, Anthony T

    2017-07-03

    There are substantial differences between the costs of medical masks and N95 respirators. Cost-effectiveness analysis is required to assist decision-makers evaluating alternative healthcare worker (HCW) mask/respirator strategies. This study aims to compare the cost-effectiveness of N95 respirators and medical masks for protecting HCWs in Beijing, China. We developed a cost-effectiveness analysis model utilising efficacy and resource use data from two cluster randomised clinical trials assessing various mask/respirator strategies conducted in HCWs in Level 2 and 3 Beijing hospitals for the 2008-09 and 2009-10 influenza seasons. The main outcome measure was the incremental cost-effectiveness ratio (ICER) per clinical respiratory illness (CRI) case prevented. We used a societal perspective which included intervention costs, the healthcare costs of CRI in HCWs and absenteeism costs. The incremental cost to prevent a CRI case with continuous use of N95 respirators when compared to medical masks ranged from US $490-$1230 (approx. 3000-7600 RMB). One-way sensitivity analysis indicated that the CRI attack rate and intervention effectiveness had the greatest impact on cost-effectiveness. The determination of cost-effectiveness for mask/respirator strategies will depend on the willingness to pay to prevent a CRI case in a HCW, which will vary between countries. In the case of a highly pathogenic pandemic, respirator use in HCWs would likely be a cost-effective intervention.

  20. SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

    International Nuclear Information System (INIS)

    Wiant, D; Squire, S; Maurer, J; Liu, H; Hayes, L; Sintay, B

    2015-01-01

    Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix

  1. SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wiant, D; Squire, S; Maurer, J; Liu, H; Hayes, L; Sintay, B [Cone Health Cancer Center, Greensboro, NC (United States)

    2015-06-15

    Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix.

  2. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    Science.gov (United States)

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and

  3. Nondepolarizing muscle relaxant improves direct laryngoscopy view with no effect on face mask ventilation

    Directory of Open Access Journals (Sweden)

    Marwan S. Rizk

    2017-07-01

    Full Text Available Background: Difficult or impossible face mask ventilation complicated with difficult tracheal intubation during anesthesia induction occurs in 0.4% of adult anesthesia cases, possibly leading to life-threatening complications. Because of such catastrophes, muscle relaxants have been recommended to be administered after confirming adequate face mask ventilation without a solid scientific validation of this principal. Methods: In this observational study, the ease of ventilation and the scores of direct laryngoscopy views before and after administration of cisatracurium were assessed in ninety young healthy adults, without anesthetic risks and without foreseen difficult intubation and who were scheduled for general elective surgeries. Results: Before muscle relaxation, 43 patients (48% were Cormack Grade I, while the remaining 47 patients (52% were either Cormack Grade II (28 patients, 31% or Cormack Grade II (19 patients, 21%. Following muscle relaxation with cisatracurium, the number of patients with Cormack Grade I significantly increased from 43 patients (48% to 65 patients (72% (p = 0.0013. Only 1 patient out of 19 patients (5% improved his Cormack grade from Grade III to Grade I while 16 out 19 patients (84% improved their Cormack grade from Grade III to Grade II after the use of cisatracurium. The quality of face mask ventilation did not differ with and without muscle relaxants in all patients. Conclusion: The use of cisatracurium in healthy young adults undergoing general elective surgeries with no anticipated difficult endotracheal intubation had no effect on the quality of face mask ventilation despite resulting in a quantifiable improvement in the laryngeal view. Resumo: Justificativa: A ventilação difícil ou impossível via máscara facial complicada pela intubação traqueal difícil durante a indução da anestesia ocorre em 0,4% dos casos de anestesia em adultos, possivelmente levando a complicações fatais. Devido a tais cat

  4. Protection by Face Masks against H1N1 Virus on Trans-Pacific Passenger Aircraft, 2009

    Centers for Disease Control (CDC) Podcasts

    2013-07-10

    Dr. Mike Miller reads an abridged version of the Emerging Infectious Diseases’ article, Protection by Face Masks against H1N1 Virus on Trans-Pacific Passenger Aircraft, 2009.  Created: 7/10/2013 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 7/11/2013.

  5. Comparison of two protocols for maxillary protraction: bone anchors versus face mask with rapid maxillary expansion

    Science.gov (United States)

    Cevidanes, Lucia; Baccetti, Tiziano; Franchi, Lorenzo; McNamara, James A.; De Clerck, Hugo

    2010-01-01

    Objective To test the hypothesis that there is no difference in the active treatment effects for maxillary advancement induced by bone-anchored maxillary protraction (BAMP) and the active treatment effects for face mask in association with rapid maxillary expansion (RME/FM). Materials and Methods This is a study on consecutively treated patients. The changes in dentoskeletal cephalometric variables from start of treatment (T1) to end of active treatment (T2) with an average T1–T2 interval of about 1 year were contrasted in a BAMP sample of 21 subjects with a RME/FM sample of 34 patients. All subjects were prepubertal at T1. Statistical comparison was performed with t-tests for independent samples. Results The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy (with a difference of 2 mm to 3 mm). Mandibular sagittal changes were similar, while vertical changes were better controlled with BAMP. The sagittal intermaxillary relationships improved 2.5 mm more in the BAMP patients. Additional favorable outcomes of BAMP treatment were the lack of clockwise rotation of the mandible as well as a lack of retroclination of the lower incisors. Conclusions The hypothesis is rejected. The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy. PMID:20578848

  6. Failed obstetric tracheal intubation and postoperative respiratory support with the ProSeal laryngeal mask airway

    NARCIS (Netherlands)

    Keller, Christian; Brimacombe, Joseph; Lirk, Philipp; Pühringer, Fritz

    2004-01-01

    The ProSeal laryngeal mask airway (ProSeal LMA) provides a better seal and probably better airway protection than the classic laryngeal mask airway (classic LMA). We report the use of the ProSeal LMA in a 26-yr-old female with HELLP syndrome for failed obstetric intubation and postoperative

  7. Telemedicine Versus Face-to-Face Evaluations by Respiratory Therapists of Mechanically Ventilated Neonates and Children: A Pilot Study.

    Science.gov (United States)

    Bell, Rebecca C; Yager, Phoebe H; Clark, Maureen E; Roumiantsev, Serguei; Venancio, Heather L; Chipman, Daniel W; Kacmarek, Robert M; Noviski, Natan N

    2016-02-01

    Mechanical ventilation is one of the most important therapeutic interventions in neonatal and pediatric ICUs. Telemedicine has been shown to reliably extend pediatric intensivist expertise to facilities where expertise is limited. If reliable, telemedicine may extend the reach of pediatric respiratory therapists (RTs) to facilities where expertise does not exist or free up existing RT resources for important face-to-face activities in facilities where expertise is limited. The aim of this study was to determine how well respiratory assessments for ventilated neonates and children correlated when performed simultaneously by 2 RTs face-to-face and via telemedicine. We conducted a pilot study including 40 assessments by 16 RTs on 11 subjects (5 neonatal ICU; 6 pediatric ICU). Anonymously completed intake forms by 2 different RTs concurrently assessing 14 ventilator-derived and patient-based respiratory variables were used to determine correlations. Forty paired assessments were performed. Median telemedicine assessment time was 8 min. The Pearson correlation coefficient (r) was used to determine agreement between continuous data, and the Cohen kappa statistics were used for binary variables. Pressure control, PEEP, breathing frequency, and FIO2 perfectly correlated (r = 1, all P Telemedicine technology was acceptable to RTs. Telemedicine evaluations highly correlated with face-to-face for 10 of 14 aspects of standard bedside respiratory assessment. Poor correlation was noted for more complex, patient-generated parameters, highlighting the importance of further investigation incorporating a virtual stethoscope. Copyright © 2016 by Daedalus Enterprises.

  8. Cephalometric variables used to predict the success of interceptive treatment with rapid maxillary expansion and face mask. A longitudinal study

    Directory of Open Access Journals (Sweden)

    Daniele Nóbrega Nardoni

    2015-02-01

    Full Text Available INTRODUCTION: Prognosis is the main limitation of interceptive treatment of Class III malocclusions. The interceptive procedures of rapid maxillary expansion (RME and face mask therapy performed in early mixed dentition are capable of achieving immediate overcorrection and maintenance of facial and occlusal morphology for a few years. Individuals presenting minimal acceptable faces at growth completion are potential candidates for compensatory orthodontic treatment, while those with facial involvement should be submitted to orthodontic decompensation for orthognathic surgery. OBJECTIVES: To investigate cephalometric variables that might predict the outcomes of orthopedic treatment with RME and face mask therapy (FM. METHODS: Cephalometric analysis of 26 Class III patients (mean age of 8 years and 4 months was performed at treatment onset and after a mean period of 6 years and 10 months at pubertal growth completion, including a subjective facial analysis. Patients was divided into two groups: success group (21 individuals and failure group (5 individuals. Discriminant analysis was applied to the cephalometric values at treatment onset. Two predictor variables were found by stepwise procedure. RESULTS: Orthopedic treatment of Class III malocclusion may have unfavorable prognosis at growth completion whenever initial cephalometric analysis reveals increased lower anterior facial height (LAFH combined with reduced angle between the condylar axis and the mandibular plane (CondAx.MP. CONCLUSION: The results of treatment with RME and face mask therapy at growth completion in Class III patients could be predicted with a probability of 88.5%.

  9. Antibiotic exposure and interpersonal variance mask the effect of ivacaftor on respiratory microbiota composition.

    Science.gov (United States)

    Peleg, Anton Y; Choo, Jocelyn M; Langan, Katherine M; Edgeworth, Deirdre; Keating, Dominic; Wilson, John; Rogers, Geraint B; Kotsimbos, Tom

    2018-01-01

    G551D is a class III mutation of the cystic fibrosis transmembrane regulator (CFTR) that results in impaired chloride channel function in cystic fibrosis (CF). Ivacaftor, a CFTR-potentiating agent improves sweat chloride, weight, lung function, and pulmonary exacerbation rate in CF patients with G551D mutations, but its effect on the airway microbiome remains poorly characterised. Twenty CF patients with at least one G551D mutation from a single centre were recruited to a 4month double-blind, placebo-controlled, crossover study of ivacaftor with 28days of active treatment. Sputum microbiota composition was assessed by 16S rRNA gene amplicon sequencing and quantitative PCR at five key time points, along with regular clinical review, respiratory function assessment, and peripheral blood testing. No significant difference in microbiota composition was observed in subjects following ivacaftor treatment or placebo (PERMANOVA P=0.95, square root ECV=-4.94, 9479 permutations). Microbiota composition variance was significantly greater between subjects, than within subjects over time (P<0.0001, Mann Whitney U test), and an additional within-patient paired assessment of microbiota similarity was therefore performed. Again, change in microbiota composition was not significantly greater during treatment with ivacaftor compared to placebo (Wilcoxon test, P=0.51). A significant change in microbiota composition was however associated with any change in antibiotic exposure, regardless of whether ivacaftor or placebo was administered (P=0.006). In a small, subgroup analysis of subjects whose antibiotic exposure did not change within the study period, a significant reduction in total bacterial load was observed during treatment with ivacaftor (P=0.004, two-tailed paired Student's t-test). The short-term impact of ivacaftor therapy on sputum microbiota composition in patients with G551D mutations are modest compared to those resulting from antibiotic exposure, and may be masked by

  10. Interruptions in Chest Compressions by Surf Lifeguards: A Comparison of Face-mask Ventilation in Over-the-head CPR vs Standard CPR

    DEFF Research Database (Denmark)

    Nørkjær, Louise; Nielsen, Lars Henrik; Bomholt, Katrine Bjørnshave

    . The International Life Saving Federation recommends CPR using face-mask ventilation. It is currently unknown if OH-CPR using face-mask ventilation improves CPR quality. We hypothesized that OH-CPR is superior to standard CPR with face-mask ventilation among surf lifeguards. Methods: Surf lifeguards were trained......Introduction: Ventilation is a priority in drowning resuscitation. Over-the-head CPR (OH-CPR), i.e. with the rescuer located at the top of the victim’s head instead of alongside the victim’s torso, has been demonstrated to be superior when doing bag-valve-mask ventilation compared to standard CPR...... in OH-CPR and standard CPR with face-mask ventilation and randomized to a crossover comparison on a manikin. CPR quality data were obtained from the manikin and video recordings. Interruptions in chest compressions were used as a primary measure of CPR quality. A sample size of 14 participants...

  11. Who is that masked person: the use of face masks on Mexico City public transportation during the Influenza A (H1N1) outbreak.

    Science.gov (United States)

    Condon, Bradly John; Sinha, Tapen

    2010-04-01

    This article examines three issues: (1) the use, over time, of facemasks in a public setting to prevent the spread of a respiratory disease for which the mortality rate is unknown; (2) the difference between the responses of male and female subjects in a public setting to unknown risks; and (3) the effectiveness of mandatory and voluntary public health measures in a public health emergency. The use of facemasks to prevent the spread of respiratory diseases in a public setting is controversial. At the height of the influenza epidemic in Mexico City in the spring of 2009, the federal government of Mexico recommended that passengers on public transport use facemasks to prevent contagion. The Mexico City government made the use of facemasks mandatory for bus and taxi drivers, but enforcement procedures differed for these two categories. Using an evidence-based approach, we collected data on the use of facemasks over a 2-week period. In the specific context of the Mexico City influenza outbreak, these data showed mask usage rates mimicked the course of the epidemic and gender difference in compliance rates among metro passengers. Moreover, there was not a significant difference in compliance with mandatory and voluntary public health measures where the effect of the mandatory measures was diminished by insufficiently severe penalties, the lack of market forces to create compliance incentives and sufficient political influence to diminish enforcement. Voluntary compliance was diminished by lack of trust in the government. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  12. The Influence of Various Factors on High School Football Helmet Face Mask Removal: A Retrospective, Cross-Sectional Analysis

    Science.gov (United States)

    Swartz, Erik E; Decoster, Laura C; Norkus, Susan A; Cappaert, Thomas A

    2007-01-01

    Context: Most research on face mask removal has been performed on unused equipment. Objective: To identify and compare factors that influence the condition of helmet components and their relationship to face mask removal. Design: A cross-sectional, retrospective study. Setting: Five athletic equipment reconditioning/recertification facilities. Participants: 2584 helmets from 46 high school football teams representing 5 geographic regions. Intervention(s): Helmet characteristics (brand, model, hardware components) were recorded. Helmets were mounted and face mask removal was attempted using a cordless screwdriver. The 2004 season profiles and weather histories were obtained for each high school. Main Outcome Measure(s): Success and failure (including reason) for removal of 4 screws from the face mask were noted. Failure rates among regions, teams, reconditioning year, and screw color (type) were compared. Weather histories were compared. We conducted a discriminant analysis to determine if weather variables, region, helmet brand and model, reconditioning year, and screw color could predict successful face mask removal. Metallurgic analysis of screw samples was performed. Results: All screws were successfully removed from 2165 (84%) helmets. At least 1 screw could not be removed from 419 (16%) helmets. Significant differences were found for mean screw failure per helmet among the 5 regions, with the Midwest having the lowest failure rate (0.08 ± 0.38) and the Southern (0.33 ± 0.72), the highest. Differences were found in screw failure rates among the 46 teams (F1,45 = 9.4, P < .01). Helmets with the longest interval since last reconditioning (3 years) had the highest failure rate, 0.47 ± 0.93. Differences in success rates were found among 4 screw types (χ21,4 = 647, P < .01), with silver screws having the lowest percentage of failures (3.4%). A discriminant analysis (Λ = .932, χ214,n=2584 = 175.34, P < .001) revealed screw type to be the strongest predictor of

  13. Evaluation of protection factors provided by full-face masks using man-test method at workplace

    International Nuclear Information System (INIS)

    Izumi, Yukio; Kinouchi, Nobuyuki; Ikezawa, Yoshio.

    1994-01-01

    From a practical angle of view to estimate the protection factors (PFs) provided by full-face masks, a number of protection factors were measured with a man-test apparatus just before the wearers started to do radiation work in radiation controlled area. PFs of the total number of 2,279 cases were measured under five simulated working conditions. The measured PFs were widely distributed from 2.3 to 6,700. About 95% of workers obtained PFs more than 50, and about 64% showed much higher PFs more than 1,000 due to good fitting. In the case of some persons, the measured PFs irregularly varied and changed to a large degree. This method is a reliable technique that has been confirmed to protect unexpected internal exposure. From the results obtained, the method should be necessary to provide a better mask and higher PF for each worker. (author)

  14. Neural circuitry of masked emotional face processing in youth with bipolar disorder, severe mood dysregulation, and healthy volunteers

    Directory of Open Access Journals (Sweden)

    Laura A. Thomas

    2014-04-01

    Full Text Available Youth with bipolar disorder (BD and those with severe, non-episodic irritability (severe mood dysregulation, SMD show face-emotion labeling deficits. These groups differ from healthy volunteers (HV in neural responses to emotional faces. It is unknown whether awareness is required to elicit these differences. We compared activation in BD (N = 20, SMD (N = 18, and HV (N = 22 during “Aware” and “Non-aware” priming of shapes by emotional faces. Subjects rated how much they liked the shape. In aware, a face (angry, fearful, happy, neutral, blank oval appeared (187 ms before the shape. In non-aware, a face appeared (17 ms, followed by a mask (170 ms, and shape. A Diagnosis-by-Awareness-by-Emotion ANOVA was not significant. There were significant Diagnosis-by-Awareness interactions in occipital regions. BD and SMD showed increased activity for non-aware vs. aware; HV showed the reverse pattern. When subjects viewed angry or neutral faces, there were Emotion-by-Diagnosis interactions in face-emotion processing regions, including the L precentral gyrus, R posterior cingulate, R superior temporal gyrus, R middle occipital gyrus, and L medial frontal gyrus. Regardless of awareness, BD and SMD differ in activation patterns from HV and each other in multiple brain regions, suggesting that BD and SMD are distinct developmental mood disorders.

  15. Neural circuitry of masked emotional face processing in youth with bipolar disorder, severe mood dysregulation, and healthy volunteers.

    Science.gov (United States)

    Thomas, Laura A; Brotman, Melissa A; Bones, Brian L; Chen, Gang; Rosen, Brooke H; Pine, Daniel S; Leibenluft, Ellen

    2014-04-01

    Youth with bipolar disorder (BD) and those with severe, non-episodic irritability (severe mood dysregulation, SMD) show face-emotion labeling deficits. These groups differ from healthy volunteers (HV) in neural responses to emotional faces. It is unknown whether awareness is required to elicit these differences. We compared activation in BD (N=20), SMD (N=18), and HV (N=22) during "Aware" and "Non-aware" priming of shapes by emotional faces. Subjects rated how much they liked the shape. In aware, a face (angry, fearful, happy, neutral, blank oval) appeared (187 ms) before the shape. In non-aware, a face appeared (17 ms), followed by a mask (170 ms), and shape. A Diagnosis-by-Awareness-by-Emotion ANOVA was not significant. There were significant Diagnosis-by-Awareness interactions in occipital regions. BD and SMD showed increased activity for non-aware vs. aware; HV showed the reverse pattern. When subjects viewed angry or neutral faces, there were Emotion-by-Diagnosis interactions in face-emotion processing regions, including the L precentral gyrus, R posterior cingulate, R superior temporal gyrus, R middle occipital gyrus, and L medial frontal gyrus. Regardless of awareness, BD and SMD differ in activation patterns from HV and each other in multiple brain regions, suggesting that BD and SMD are distinct developmental mood disorders. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Spatial Attention-Related Modulation of the N170 by Backward Masked Fearful Faces

    Science.gov (United States)

    Carlson, Joshua M.; Reinke, Karen S.

    2010-01-01

    Facial expressions are a basic form of non-verbal communication that convey important social information to others. The relevancy of this information is highlighted by findings that backward masked facial expressions facilitate spatial attention. This attention effect appears to be mediated through a neural network consisting of the amygdala,…

  17. Application of Dual Mask for Postoperative Respiratory Support in Obstructive Sleep Apnea Patient

    Directory of Open Access Journals (Sweden)

    Jahan Porhomayon

    2013-01-01

    Full Text Available In some conditions continuous positive airway pressure (CPAP or bilevel positive airway pressure (BIPAP therapy alone fails to provide satisfactory oxygenation. In these situations oxygen (O2 is often being added to CPAP/BIPAP mask or hose. Central sleep apnea and obstructive sleep apnea (OSA are often present along with other chronic conditions, such as chronic obstructive pulmonary disease (COPD, congestive heart failure, pulmonary fibrosis, neuromuscular disorders, chronic narcotic use, or central hypoventilation syndrome. Any of these conditions may lead to the need for supplemental O2 administration during the titration process. Maximization of comfort, by delivering O2 directly via a nasal cannula through the mask, will provide better oxygenation and ultimately treat the patient with lower CPAP/BIPAP pressure.

  18. Comparing the Efficacy of Face Mask CPAP with Nasopharyngeal CPAP for Neonatal Transport after Delivery

    OpenAIRE

    Manizheh Mostafa-Gharehbaghi; Ali Peirovifar; Bahram Karimi

    2013-01-01

    Background: Preterm infants have respiratory failure and complications because surfactant in alveolus is low. CPAP (Continuous positive airway pressure) is a method for respiratory support in pre-term neonates and is provided by different equipment and methods. This study aims to compare two different routes of CPAP delivery in preterm newborn infants and to determine the need for surfactant replacement therapy in two groups. Materials and Methods: This is a randomized controlled clinical tri...

  19. A modified face mask device for radiotherapy of head and neck tumor

    International Nuclear Information System (INIS)

    Adamietz, I.A.; Kremmin, B.; Emminger, A.

    1991-01-01

    The reproducibility during radiotherapy of head and neck tumors has been significantly improved by special devices like individual masks. However, the temporary fixation of head and neck region to the irradiation berth induces in many patients anxiety state and reduces this way the compliance. By means of modification of the device used till now a new model in which the set up mask is only coupled to the berth, could be developed. The clinical evaluation showed that this form of fixation device is much better tolerated by the patients and can be adapted without any problems to all equipment pieces in a radiotherapy department. The estimated reproducibility was comparable to that obtained with mounted device. The average translation of the central beam during 21 days observation period was 2.6±1.4 mm (0 to 9 mm) in the sagittal plane and 3.4±1.0 mm (1 to 8 mm) in the frontal plane. (orig.) [de

  20. PENGGUNAAN FACE-MASK & EKSPANSI PALATAL PADA PERAWATAN MALOKLUSI KLAS III (Studi Pustaka)

    OpenAIRE

    Krisnawati Krisnawati

    2015-01-01

    Class III skeletal anomaly is one of the most difficult malocclusions to correct in orthodontics. Orthodontist usually involved chincup appliances to restrain mandibular growth, camouflage techniques to advances maxillary incisors and retract mandibular incisors or waiting untul growth ceased to pursue orthognathic surgery. Many studies found that most of Class III malocclusions were characterized by maxillary retrognathism. In the late 1960s, the Delaire mask was popularized to protract the ...

  1. Laser Doppler imaging of cutaneous blood flow through transparent face masks: a necessary preamble to computer-controlled rapid prototyping fabrication with submillimeter precision.

    Science.gov (United States)

    Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H

    2008-01-01

    A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.

  2. Nonconscious Influences from Emotional Faces: A Comparison of Visual Crowding, Masking, and Continuous Flash Suppression

    Directory of Open Access Journals (Sweden)

    Nathan eFaivre

    2012-05-01

    Full Text Available In the study of nonconscious processing, different methods have been used in order to renderstimuli invisible. While their properties are well described, the level at which they disruptnonconscious processing remains unclear. Yet, such accurate estimation of the depth ofnonconscious processes is crucial for a clear differentiation between conscious and nonconsciouscognition. Here, we compared the processing of facial expressions rendered invisible through gazecontingentcrowding (GCC, masking, and continuous flash suppression (CFS, three techniquesrelying on different properties of the visual system. We found that both pictures and videos of happyfaces suppressed from awareness by GCC were processed such as to bias subsequent preferencejudgments. The same stimuli manipulated with visual masking and CFS did not bias significantlypreference judgments, although they were processed such as to elicit perceptual priming. Asignificant difference in preference bias was found between GCC and CFS, but not between GCCand masking. These results provide new insights regarding the nonconscious impact of emotionalfeatures, and highlight the need for rigorous comparisons between the different methods employedto prevent perceptual awareness.

  3. Comparison of the OxyMask and Venturi Mask in the Delivery of Supplemental Oxygen: Pilot Study in Oxygen-Dependent Patients

    OpenAIRE

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia.METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a ra...

  4. [Orthodontic treatment of malocclusion Class III in patients aged 6-12 by Postnikov appliance, face mask and bracket system].

    Science.gov (United States)

    Postnikov, M A; Trunin, D A; Pankratova, N V; Nesterov, A M; Sadykov, M I; Ostankov, S A

    2018-01-01

    The diagnostics and treatment of malocclusion Class III in patients aged 6-12 is an vital problem in orthodontics. Method of orthodontic treatment of malocclusion Class III in patients with the help of improved and patented orthodontic construction - 'Postnikov appliance' - and face mask and bracket system is analysed in the article. Orthodontic treatment of malocclusion Class III was examined in 24 patients aged 6-12 by the suggested method. All patients were examined clinically and with the help af additional diagnostic methods: head cephalometry in lateral position with further data analysis in Dolphin Imaging (USA). The use of computer technologies in Dolphin Imaging helps to controll the process of correction of dentition correlation in different stages of treatment, to reduce the period of treatment of malocclusion Class III in patients aged 6-12 and to improve face esthetics and life quality ratio.

  5. Processing of masked and unmasked emotional faces under different attentional conditions: an electrophysiological investigation.

    Directory of Open Access Journals (Sweden)

    Marzia eDel Zotto

    2015-10-01

    Full Text Available In order to investigate the interactions between non-spatial selective attention, awareness and emotion processing, we carried out an ERP study using a backward masking paradigm, in which angry, fearful, happy and neutral facial expressions were presented, while participants attempted to detect the presence of one or the other category of facial expressions in the different experimental blocks. ERP results showed that negative emotions enhanced an early N170 response over temporal-occipital leads in both masked and unmasked conditions, independently of selective attention. A later effect arising at the P2 was linked to awareness. Finally, selective attention was found to affect the N2 and N3 components over occipito-parietal leads. Our findings reveal that i the initial processing of facial expressions arises prior to attention and awareness; ii attention and awareness give rise to temporally distinct periods of activation independently of the type of emotion with only a partial degree of overlap; and iii selective attention appears to be influenced by the emotional nature of the stimuli, which in turn impinges on unconscious processing at a very early stage. This study confirms previous reports that negative facial expressions can be processed rapidly, in absence of visual awareness and independently of selective attention. On the other hand, attention and awareness may operate in a synergistic way, depending on task demand.

  6. Pilot scale test and commercialization of sago hydrogel for face mask and wound dressing

    International Nuclear Information System (INIS)

    Khairul Zaman Hj. Mohd Dahlan; Kamaruddin Hashim; Zulkafli Ghazali

    2008-01-01

    Commercialization of sago hydrogel as facial mask could be considered as one of the successful story of the radiation processing of natural polymer. However, the process of bringing the product from laboratory to market is not an easy task. The commercialization of new product through entrepreneur requires tremendous energy and funding if compare through company that is already in the same business. Hence, it would require an entrepreneur that is resilient, has certain quality such as hard working, flexible, persistence etc. In addition, the continuous support and 'follow through' from laboratory to market, by the inventor and government agency are equally important for the success of the commercialization of the product or technology. (author)

  7. SU-D-BRA-02: Motion Assessment During Open Face Mask SRS Using CBCT and Surface Monitoring

    International Nuclear Information System (INIS)

    Williams, BB; Fox, CJ; Hartford, AC; Gladstone, DJ

    2016-01-01

    Purpose: To assess the robustness of immobilization using open-face mask technology for linac-based stereotactic radiosurgery (SRS) with multiple non-coplanar arcs via repeated CBCT acquisition, with comparison to contemporaneous optical surface tracking data. Methods: 25 patients were treated in open faced masks with cranial SRS using 3–4 non-coplanar arcs. Repeated CBCT imaging was performed to verify the maintenance of proper patient positioning during treatment. Initial patient positioning was performed based on prescribed shifts and optical surface tracking. Positioning refinements employed rigid 3D-matching of the planning CT and CBCT images and were implemented via automated 6DOF couch control. CBCT imaging was repeated following the treatment of all non-transverse beams with associated couch kicks. Detected patient translations and rotations were recorded and automatically corrected. Optical surface tracking was applied throughout the treatments to monitor motion, and this contemporaneous patient positioning data was recorded to compare against CBCT data and 6DOF couch adjustments. Results: Initial patient positions were refined on average by translations of 3±1mm and rotations of ±0.9-degrees. Optical surface tracking corroborated couch corrections to within 1±1mm and ±0.4-degrees. Following treatment of the transverse and subsequent superior-oblique beam, average translations of 0.6±0.4mm and rotations of ±0.4-degrees were reported via CBCT, with optical surface tracking in agreement to within 1.1±0.6mm and ±0.6-degrees. Following treatment of the third beam, CBCT indicated additional translations of 0.4±0.2mm and rotations of ±0.3-degrees. Cumulative couch corrections resulted in 0.7 ± 0.4mm average magnitude translations and rotations of ±0.4-degrees. Conclusion: Based on CBCT measurements of patients during SRS, the open face mask maintained patient positioning to within 1.5mm and 1-degree with >95% confidence. Patient positioning

  8. SU-D-BRA-02: Motion Assessment During Open Face Mask SRS Using CBCT and Surface Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Williams, BB; Fox, CJ; Hartford, AC; Gladstone, DJ [Dartmouth-Hitchcock Medical Center, Lebanon, NH (Lebanon)

    2016-06-15

    Purpose: To assess the robustness of immobilization using open-face mask technology for linac-based stereotactic radiosurgery (SRS) with multiple non-coplanar arcs via repeated CBCT acquisition, with comparison to contemporaneous optical surface tracking data. Methods: 25 patients were treated in open faced masks with cranial SRS using 3–4 non-coplanar arcs. Repeated CBCT imaging was performed to verify the maintenance of proper patient positioning during treatment. Initial patient positioning was performed based on prescribed shifts and optical surface tracking. Positioning refinements employed rigid 3D-matching of the planning CT and CBCT images and were implemented via automated 6DOF couch control. CBCT imaging was repeated following the treatment of all non-transverse beams with associated couch kicks. Detected patient translations and rotations were recorded and automatically corrected. Optical surface tracking was applied throughout the treatments to monitor motion, and this contemporaneous patient positioning data was recorded to compare against CBCT data and 6DOF couch adjustments. Results: Initial patient positions were refined on average by translations of 3±1mm and rotations of ±0.9-degrees. Optical surface tracking corroborated couch corrections to within 1±1mm and ±0.4-degrees. Following treatment of the transverse and subsequent superior-oblique beam, average translations of 0.6±0.4mm and rotations of ±0.4-degrees were reported via CBCT, with optical surface tracking in agreement to within 1.1±0.6mm and ±0.6-degrees. Following treatment of the third beam, CBCT indicated additional translations of 0.4±0.2mm and rotations of ±0.3-degrees. Cumulative couch corrections resulted in 0.7 ± 0.4mm average magnitude translations and rotations of ±0.4-degrees. Conclusion: Based on CBCT measurements of patients during SRS, the open face mask maintained patient positioning to within 1.5mm and 1-degree with >95% confidence. Patient positioning

  9. Effect of a short training on neonatal face-mask ventilation performance in a low resource setting.

    Directory of Open Access Journals (Sweden)

    Alessandro Mazza

    Full Text Available We assessed whether a short training, effective in a high resource country, was able to improve the quality of face-mask ventilation (FMV in a low resource setting.Local healthcare providers at the Centre Médico-Social, Kouvè, Togo were asked to ventilate a neonatal leak-free manikin before (time-t1 and after (t2 a two-minute training session. Immediately after this section, a further two-minute training with participants aware of the data monitor was offered. Finally, a third 1-minute FMV round (t3 was performed by each participant. Ventilatory parameters were recorded using a computerized system. Primary outcome was the percentage of breaths with relevant mask leak (>25%. Secondary outcomes were percentages of breaths with a low peak inspiratory pressure (PIP35 cm H2O.Twenty-six subjects participated in the study. The percentage of relevant mask leak significantly decreased (p35 cm H2O was 19.5% (SD 32.8% at t1 and 39.2% (SD 37.7% at t2 (padj = 0.27; β = +0.61, SE = 0.36 and significantly decreased (padj = 0.01; β = -1.61, SE = 0.55 to 6.0% (SD 15.4% at t3.A 2-minute training on FMV, effective in a high resource country, had a positive effect also in a low resource setting. FMV performance further improved after an extra 2-minute verbal recall plus real time feedback. Although the training was extended, it still does not cost much time and effort. Further studies are needed to establish if these basic skills are transferred in real patients and if they are maintained over time.

  10. Lung function after cold-water dives with a standard scuba regulator or full-face-mask during wintertime.

    Science.gov (United States)

    Uhlig, Florian; Muth, Claus-Martin; Tetzlaff, Kay; Koch, Andreas; Leberle, Richard; Georgieff, Michael; Winkler, Bernd E

    2014-06-01

    Full-face-masks (FFM) prevent the diver's face from cold and can support nasal breathing underwater. The aim of the study was to evaluate the effect of the use of FFMs on lung function and wellbeing. Twenty-one, healthy, non-asthmatic divers performed two cold-water dives (4⁰C, 25 min, 10 metres' depth) - one with a FFM and the other with a standard scuba regulator (SSR). Spirometry was performed before and after each dive and well-being and cold sensation were assessed after the dives. Significant decreases in forced vital capacity (FVC), forced expiratory volume in one second (FEV₁) and midexpiratory flow at 75% of FVC (MEF₇₅) occurred after both FFM and SSR dives. Changes in FVC and FEV₁ did not differ significantly between FFM and SSR dives. However, the mid-expiratory flows measured at 50% and 25% of FVC (MEF₅₀ and MEF₂₅) were significantly lower 10 minutes after the FFM dive compared to 10 minutes after the SSR dive. The wellbeing and cold sensation of the divers were significantly improved with FFM dives compared to SSR dives. Cold-water dives during wintertime can be associated with airway narrowing. During cold-water dives, the use of a FFM appears to reduce the cold sensation and enhance the well-being of the divers. However, a FFM does not appear to prevent airway narrowing in healthy, non-asthmatic subjects.

  11. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    Science.gov (United States)

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, pmask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.

    Science.gov (United States)

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.

  13. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study* **

    Science.gov (United States)

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653

  14. Maxillary Protraction With Intermaxillary Elastics to Miniplates Versus Bone-Anchored Face-Mask Therapy in Cleft Lip and Palate Patients.

    Science.gov (United States)

    Jahanbin, Arezoo; Kazemian, Mozhgan; Eslami, Neda; Pouya, Iman Saeedi

    2016-07-01

    Cleft lip and palate patients usually have deficient maxilla due to postsurgical scars. The aim this study was to compare the effectiveness of miniplates-anchored face-mask therapy versus intermaxillary elastics to miniplates for maxillary traction in cleft lip and palate patients. This clinical trial included 11 prepubertal patients with cleft lip and palate. Initially, a w-arch expander was cemented and activated 3 mm per month to overcorrect the crossbite. Then, the patients were divided into 2 groups: mini-plate-anchored face-mask (n = 5): 2 miniplates were placed in the maxilla and the patients were instructed to wear a face-mask for 12 to 14 hours/per day. Intermaxillary elastics to miniplates (n = 6): 2 miniplates were inserted in the maxilla; 1 on each side and 2 miniplates were placed in the anterior mandible on both sides. Intermaxillary elastics with a force of 250 g per side were attached to the hooks. Cephalometric parameters before treatment (T1) and after achieving positive overjet (T2) were compared between the 2 groups. Fisher exact, paired, and independent t tests were used for statistical comparison. At T1 or T2 there was not a significant difference between the 2 groups in the skeletal, dental, and soft tissue variables. According to results of our preliminary study, intermaxillary elastics to miniplates might have a promising effect as an alternative for face mask therapy in maxillary protraction of cleft lip and palate patients.

  15. Evaluation of cephalometric changes in patients with class III malocclusion in mixed dentition period following face mask therapy and slow maxillary expansion

    Directory of Open Access Journals (Sweden)

    Ahmad Akhondi MS.

    2008-11-01

    Full Text Available "nBackground and Aim: Among different treatments of patients with Class III malocclusion , orthopedic protraction of maxilla has been known as an effective method in mixed dentition period. The aim of this study was to evaluate the cephalometric changes of Cl III patients in mixed dentition period following face mask therapy and slow maxillary expansion. "nMaterials and Methods: This was a before-after study which was conducted on 10 children in mixed dentition period, who had class III malocclusion and maxillary deficiency according to the Stiener and Mc Namara's analysis. The patients were all treated by protraction face mask and slow maxillary expansion. The cephalometric changes of maxilla , mandible and dental relations during the treatment were analyzed by Paired sample T Test. P<0.05 was considered as the level of significant. "nResults: The overjet increasement was 1.7mm. Co. ANS distance improvement was 5.6mm, Ptm.ANS distance increasing was 3mm, and ultimately improvement of Gf.s distance was 1.5mm which were all statistically significant (p<0.05. "nConclusion: Based on the results of this study, face mask therapy with slow maxillary expansion is able to improve the horizotal position of maxilla, in patients with Cl III malocclusion , in mixed dentition period.

  16. Dissociative part-dependent biopsychosocial reactions to backward masked angry and neutral faces: An fMRI study of dissociative identity disorder.

    Science.gov (United States)

    Schlumpf, Yolanda R; Nijenhuis, Ellert R S; Chalavi, Sima; Weder, Ekaterina V; Zimmermann, Eva; Luechinger, Roger; La Marca, Roberto; Reinders, A A T Simone; Jäncke, Lutz

    2013-01-01

    The Theory of Structural Dissociation of the Personality (TSDP) proposes that dissociative identity disorder (DID) patients are fixed in traumatic memories as "Emotional Parts" (EP), but mentally avoid these as "Apparently Normal Parts" of the personality (ANP). We tested the hypotheses that ANP and EP have different biopsychosocial reactions to subliminally presented angry and neutral faces, and that actors instructed and motivated to simulate ANP and EP react differently. Women with DID and matched healthy female actors (CON) were as ANP and EP (DIDanp, DIDep, CONanp, CONep) consecutively exposed to masked neutral and angry faces. Their brain activation was monitored using functional magnetic resonance imaging. The black-and-white dotted masks preceding and following the faces each had a centered colored dot, but in a different color. Participants were instructed to immediately press a button after a perceived color change. State anxiety was assessed after each run using the STAI-S. Final statistical analyses were conducted on 11 DID patients and 15 controls for differences in neural activity, and 13 DID patients and 15 controls for differences in behavior and psychometric measures. Differences between ANP and EP in DID patients and between DID and CON in the two dissociative parts of the personality were generally larger for neutral than for angry faces. The longest reaction times (RTs) existed for DIDep when exposed to neutral faces. Compared to DIDanp, DIDep was associated with more activation of the parahippocampal gyrus. Following neutral faces and compared to CONep, DIDep had more activation in the brainstem, face-sensitive regions, and motor-related areas. DIDanp showed a decreased activity all over the brain in the neutral and angry face condition. There were neither significant within differences nor significant between group differences in state anxiety. CON was not able to simulate genuine ANP and EP biopsychosocially. DID patients have dissociative

  17. Dissociative part-dependent biopsychosocial reactions to backward masked angry and neutral faces: An fMRI study of dissociative identity disorder☆

    Science.gov (United States)

    Schlumpf, Yolanda R.; Nijenhuis, Ellert R.S.; Chalavi, Sima; Weder, Ekaterina V.; Zimmermann, Eva; Luechinger, Roger; La Marca, Roberto; Reinders, A.A.T. Simone; Jäncke, Lutz

    2013-01-01

    Objective The Theory of Structural Dissociation of the Personality (TSDP) proposes that dissociative identity disorder (DID) patients are fixed in traumatic memories as “Emotional Parts” (EP), but mentally avoid these as “Apparently Normal Parts” of the personality (ANP). We tested the hypotheses that ANP and EP have different biopsychosocial reactions to subliminally presented angry and neutral faces, and that actors instructed and motivated to simulate ANP and EP react differently. Methods Women with DID and matched healthy female actors (CON) were as ANP and EP (DIDanp, DIDep, CONanp, CONep) consecutively exposed to masked neutral and angry faces. Their brain activation was monitored using functional magnetic resonance imaging. The black-and-white dotted masks preceding and following the faces each had a centered colored dot, but in a different color. Participants were instructed to immediately press a button after a perceived color change. State anxiety was assessed after each run using the STAI-S. Final statistical analyses were conducted on 11 DID patients and 15 controls for differences in neural activity, and 13 DID patients and 15 controls for differences in behavior and psychometric measures. Results Differences between ANP and EP in DID patients and between DID and CON in the two dissociative parts of the personality were generally larger for neutral than for angry faces. The longest reaction times (RTs) existed for DIDep when exposed to neutral faces. Compared to DIDanp, DIDep was associated with more activation of the parahippocampal gyrus. Following neutral faces and compared to CONep, DIDep had more activation in the brainstem, face-sensitive regions, and motor-related areas. DIDanp showed a decreased activity all over the brain in the neutral and angry face condition. There were neither significant within differences nor significant between group differences in state anxiety. CON was not able to simulate genuine ANP and EP biopsychosocially

  18. Smoke Mask

    Science.gov (United States)

    2003-01-01

    Smoke inhalation injury from the noxious products of fire combustion accounts for as much as 80 percent of fire-related deaths in the United States. Many of these deaths are preventable. Smoke Mask, Inc. (SMI), of Myrtle Beach, South Carolina, is working to decrease these casualties with its line of life safety devices. The SMI personal escape hood and the Guardian Filtration System provide respiratory protection that enables people to escape from hazardous and unsafe conditions. The breathing filter technology utilized in the products is specifically designed to supply breathable air for 20 minutes. In emergencies, 20 minutes can mean the difference between life and death.

  19. Respiratory

    Science.gov (United States)

    The words "respiratory" and "respiration" refer to the lungs and breathing. ... Boron WF. Organization of the respiratory system. In: Boron WF, Boulpaep EL, eds. Medical Physiology . 3rd ed. Philadelphia, PA: Elsevier; 2017:chap 26.

  20. Shades of Emotion: What the Addition of Sunglasses or Masks to Faces Reveals about the Development of Facial Expression Processing

    Science.gov (United States)

    Roberson, Debi; Kikutani, Mariko; Doge, Paula; Whitaker, Lydia; Majid, Asifa

    2012-01-01

    Three studies investigated developmental changes in facial expression processing, between 3 years-of-age and adulthood. For adults and older children, the addition of sunglasses to upright faces caused an equivalent decrement in performance to face inversion. However, younger children showed "better" classification of expressions of faces wearing…

  1. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    Science.gov (United States)

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  2. Orthopedic treatment of Class III malocclusion with rapid maxillary expansion combined with a face mask: a cephalometric assessment of craniofacial growth patterns

    Directory of Open Access Journals (Sweden)

    Daniella Torres Tagawa

    2012-06-01

    Full Text Available OBJECTIVE: The aim of this prospective study was to assess potential changes in the cephalometric craniofacial growth pattern of 17 children presenting Angle Class III malocclusion treated with a Haas-type expander combined with a face mask. METHODS: Lateral cephalometric radiographs were taken at beginning (T1 and immediately after removal of the appliances (T2, average of 11 months of treatment. Linear and angular measurements were used to evaluate the cranial base, dentoskeletal changes and facial growth pattern. RESULTS: The length of the anterior cranial base experienced a reduction while the posterior cranial base assumed a more vertical position at T1. Some maxillary movement occurred, there was no rotation of the palatal plane, there was a slight clockwise rotation of the mandible, although not significant. The ANB angle increased, thereby improving the relationship between the jaws; dentoalveolar compensation was more evident in the lower incisors. Five out of 12 cases (29.41% showed the following changes: In one case the pattern became more horizontal and in four cases more vertical. CONCLUSIONS: It was concluded after a short-term assessment that treatment with rapid maxillary expansion (RME associated with a face mask was effective in the correction of Class III malocclusion despite the changes in facial growth pattern observed in a few cases.

  3. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    Science.gov (United States)

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  4. Thin-plate spline analysis of treatment effects of rapid maxillary expansion and face mask therapy in early Class III malocclusions.

    Science.gov (United States)

    Baccetti, T; Franchi, L; McNamara, J A

    1999-06-01

    An effective morphometric method (thin-plate spline analysis) was applied to evaluate shape changes in the craniofacial configuration of a sample of 23 children with Class III malocclusions in the early mixed dentition treated with rapid maxillary expansion and face mask therapy, and compared with a sample of 17 children with untreated Class III malocclusions. Significant treatment-induced changes involved both the maxilla and the mandible. Major deformations consisted of forward displacement of the maxillary complex from the pterygoid region and of anterior morphogenetic rotation of the mandible, due to a significant upward and forward direction of growth of the mandibular condyle. Significant differences in size changes due to reduced increments in mandibular dimensions were associated with significant shape changes in the treated group.

  5. Early orthopedic correction of skeletal Class III malocclusion using combined reverse twin block and face mask therapy

    Directory of Open Access Journals (Sweden)

    Vinay Kumar Chugh

    2015-01-01

    Full Text Available A 6-year 8-month-old girl presented with a moderate Class III malocclusion characterized by mid-face deficiency and an anterior cross bite. In the first phase, the patient was treated with combination of reverse twin block and facemask therapy. In phase two, fixed appliances were placed in the permanent dentition. The post treatment results were good and a favorable growth tendency could be observed. The correction of the Class III malocclusion occurred by a combination of skeletal and dental improvements. This report shows successful correction of skeletal Class III malocclusion in the early transitional dentition using combination therapy.

  6. Individuals and Their Masks

    Directory of Open Access Journals (Sweden)

    Belén Altuna

    2009-08-01

    Full Text Available This essay works on the opposition between face and mask, where ‘face’ is understood as that which makes every human being singular, and makes visible her or his unique worth, while ‘mask’ is understood as whatever hides that singularity, and refers to a category, stereotype or cliché. The etymological history that relates face and mask to the concept of person, and the history of modern portrait painting, which alternates representations of face and mask, both lead to a discussion with authors who diagnose a contemporary “defeat of the face” as a result of the crisis of humanism and of ethical individualism, which give meaning and dignity to that face.

  7. Gilded Silver Mask

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    This gilded silver mask from the Liao Dynasty is 31 cm long and 22.2 cm wide. The plump oval face was designed with a protruding brow ridge, narrow eyes, high-bridged nose and closed mouth. The chin is slightly round against a thin neck, the ears are long and the hair can be clearly seen from the finely carved lines. The use of masks was recorded as

  8. Flat Feline Faces: Is Brachycephaly Associated with Respiratory Abnormalities in the Domestic Cat (Felis catus)?

    Science.gov (United States)

    Farnworth, Mark J; Chen, Ruoning; Packer, Rowena M A; Caney, Sarah M A; Gunn-Moore, Danièlle A

    2016-01-01

    There has been little research into brachycephalism and associated disorders in cats. A questionnaire aimed at cat owners was used to determine the relationship between feline facial conformation and owner-reported cat management requirements and respiratory abnormalities. Owner-submitted photographs of cats were used to develop novel measures of skull conformation. One thousand valid questionnaires were received. Within these there were 373 valid photographs that allowed measurement of muzzle ratio (M%) and 494 that allowed nose position ratio (NP%). The data included 239 cats for which both measurements were available. Owners reported lifestyle factors (e.g. feeding type, grooming routine, activity level), physical characteristics (e.g. hair length) and other health characteristics of their cat (e.g. tear staining, body condition score). A composite respiratory score (RS) was calculated for each cat using their owner's assessment of respiratory noise whilst their cat was asleep and then breathing difficulty following activity. Multivariate analyses were carried out using linear models to explore the relationship between RS and facial conformation, and lifestyle risk factors. The results showed that reductions in NP% and M% were significantly associated with RS (P dogs.

  9. Faces

    DEFF Research Database (Denmark)

    Mortensen, Kristine Køhler; Brotherton, Chloe

    2018-01-01

    for the face the be put into action. Based on an ethnographic study of Danish teenagers’ use of SnapChat we demonstrate how the face is used as a central medium for interaction with peers. Through the analysis of visual SnapChat messages we investigate how SnapChat requires the sender to put an ‘ugly’ face...... already secured their popular status on the heterosexual marketplace in the broad context of the school. Thus SnapChat functions both as a challenge to beauty norms of ‘flawless faces’ and as a reinscription of these same norms by further manifesting the exclusive status of the popular girl...

  10. Comparison of short-term effects between face mask and skeletal anchorage therapy with intermaxillary elastics in patients with maxillary retrognathia.

    Science.gov (United States)

    Ağlarcı, Cahide; Esenlik, Elçin; Fındık, Yavuz

    2016-06-01

    The aim of this study was to compare the short-term dental and skeletal effects of a face mask (FM) with those of skeletal anchorage (SA) therapy with intermaxillary elastics in prepubertal patients with skeletal Class III malocclusion. Fifty patients with skeletal Class III malocclusion and maxillary deficiency were divided into two groups. In the FM group, an FM was applied by a bite plate with a force of 400g for each side. In the SA group, mini-plates were placed between mandibular lateral incisors and canines, and mini-implants were inserted between maxillary second premolars and first molars. A bite plate was inserted into the upper arch, and Class III elastics were applied with a force of 200g between each mini-plate and mini-implant. Mean treatment durations were 0.52±0.09 years for FM and 0.76±0.09 years for SA. After the treatment, statistically significant increases in SNA°, ANB°, A-y, 1-NA, SnGoGn°, Co-A, Co-Gn, and A-Nperp, and reductions in SNB° and FH┴N-Pg were observed in both groups, and these changes were similar in both groups. In the FM group, 1-NB decreased significantly, and in the SA group, it increased significantly (P journals.permissions@oup.com.

  11. Certainties and Uncertainties Facing Emerging Respiratory Infectious Diseases: Lessons from SARS

    Directory of Open Access Journals (Sweden)

    Yee-Chun Chen

    2008-06-01

    Full Text Available Every emerging infectious disease is a challenge to the whole of mankind. There are uncertainties regarding whether there will be a pandemic, if it will be caused by the highly pathogenic H5N1 influenza virus, when or where it will occur, how imminent or how severe it will be. No one can accurately predict if and when a given virus will become a pandemic virus. Pandemic prevention strategies must be based on preparing for the unexpected and being capable of reacting accordingly. There is growing evidence that infection control measures were helpful in containment of severe acute respiratory syndrome (SARS as well as avian influenza. Compliance of standard infection control measures, intensive promotion of hand and respiratory hygiene, vigilance and triage of patients with febrile illness, and specific infection control measures are key components to contain a highly contagious disease in hospital and to protect healthcare workers, patients and visitors. The importance of standard precautions for any patient and cleaning and disinfection for the healthcare environment cannot be overemphasized. SARS illustrated dramatically the potential of air travel and globalization for the dissemination of an emerging infectious disease. To prevent the potential serious consequences of pandemic influenza, timely implementation of pharmaceutical and non-pharmaceutical interventions locally within the outbreak area is the key to minimizing global spread. Herein, we relate our perspective on useful lessons derived from a review of the SARS epidemic that may be useful to physicians, especially when looking ahead to the next epidemic.

  12. 42 CFR 84.117 - Gas mask containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas mask containers; minimum requirements. 84.117... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.117 Gas mask containers; minimum requirements. (a) Gas masks shall be equipped with a substantial...

  13. Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients

    Science.gov (United States)

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425

  14. Ergonomic evaluation of pilot oxygen mask designs

    NARCIS (Netherlands)

    Lee, W.; Yang, Xiaopeng; Jung, Daehan; Park, Seikwon; Kim, Heeeun; You, Heecheon

    2018-01-01

    A revised pilot oxygen mask design was developed for better fit to the Korean Air Force pilots’ faces. The present study compared an existing pilot oxygen mask and a prototype of the revised mask design with 88 Korean Air Force pilots in terms of subjective discomfort, facial contact pressure,

  15. 21 CFR 868.5570 - Nonrebreathing mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonrebreathing mask. 868.5570 Section 868.5570...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5570 Nonrebreathing mask. (a) Identification. A nonrebreathing mask is a device fitting over a patient's face to administer oxygen. It utilizes...

  16. Gamma camera with reflectivity mask

    International Nuclear Information System (INIS)

    Stout, K.J.

    1980-01-01

    In accordance with the present invention there is provided a radiographic camera comprising: a scintillator; a plurality of photodectors positioned to face said scintillator; a plurality of masked regions formed upon a face of said scintillator opposite said photdetectors and positioned coaxially with respective ones of said photodetectors for decreasing the amount of internal reflection of optical photons generated within said scintillator. (auth)

  17. Respiratory tract infections and its preventive measures among hajj pilgrims, 2010: A nested case control study

    Directory of Open Access Journals (Sweden)

    Mohammad Hassan Emamian

    2013-01-01

    Conclusions: This study showed that measures such as seasonal influenza vaccination, use of face masks and personal prayer carpet have no effect on the incidence of respiratory tract infections. However, washing throat and mouth with salt water can be considered the most effective preventive measures.

  18. Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head

    International Nuclear Information System (INIS)

    Lopatta, E.; Liesenfeld, S.M.; Bank, P.; Guenther, R.; Wiezorek, T.; Wendt, T.G.; Wurm, R.

    2003-01-01

    Background: For high precision radiotherapy of the neurocranium a precise, reproducible positioning technique is the basic pre-requisite. The aim of this study was to assess the influence of a modification of the commercially available stereotactical BrainLab trademark -head mask system on accuracy in patient positioning during fractionated radiotherapy. Material and Methods: 29 patients were treated with stereotactic radiotherapy of the head. Immobilization was provided by a two layer thermoplastic mask system (BrainLab trademark). 18 of these patients received an additional custom made fixation either of the upper jaw (OKF) or of the mandibula (UKF). The positioning accuracy was assessed by measurements of the shifting of anatomical landmarks in relation to therigid mask system on biplanar simulator films using a digital imaging system. Before each measurement a fine adjustment of the simulator to an optical ring system was performed. The reference radiographs were done just before CT-planning. During a 2-7 weeks lasting course of radiotherapy displacement measurements in relation to the reference images for all three dimensions (z, y and x) were done once a week. In 29 patients 844 measurements were analyzed. Results: An additional jaw fixation improves the reproducibility of patient positioning significantly in all three spatial dimensions. The standard deviation in lateral direction (x) was 0.6 mm with jaw fixation vs. 0.7 mm without jaw fixation (p [de

  19. Unmasking Zorro: functional importance of the facial mask in the Masked Shrike (Lanius nubicus)

    OpenAIRE

    Reuven Yosef; Piotr Zduniak; Piotr Tryjanowski

    2012-01-01

    The facial mask is a prominent feature in the animal kingdom. We hypothesized that the facial mask of shrikes allows them to hunt into the sun, which accords them detection and surprise-attack capabilities. We conducted a field experiment to determine whether the mask facilitated foraging while facing into the sun. Male shrikes with white-painted masks hunted facing away from the sun more than birds with black-painted masks, which are the natural color, and more than individuals in the contro...

  20. International Space Station (ISS) Emergency Mask (EM) Development

    Science.gov (United States)

    Toon, Katherine P.; Hahn, Jeffrey; Fowler, Michael; Young, Kevin

    2011-01-01

    The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

  1. Clay Mask Workshop

    Science.gov (United States)

    Gamble, David L.

    2012-01-01

    Masks can represent so many things, such as emotions (happy, sad, fearful) and power. The familiar "comedy and tragedy" masks, derived from ancient Greek theater, are just one example from mask history. Death masks from the ancient Egyptians influenced the ancient Romans into creating similar masks for their departed. Masks can represent many…

  2. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial.

    Science.gov (United States)

    Neuzeret, Pierre-Charles; Morin, Laurent

    2017-11-01

    Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  3. Impacto do acoplamento de máscara facial sobre a oxigenação Impacto del acoplamiento de la máscara facial sobre la oxigenación Oxygenation: the impact of face mask coupling

    Directory of Open Access Journals (Sweden)

    Waldemar Montoya de Gregori

    2005-10-01

    la CEO2, (concentración expirada de O2, la eficacia de la técnica de oxigenación con máscara facial, en las condiciones habitualmente empleadas por los anestesiólogos, simulando situaciones de vaciamientos progresivos. MÉTODO: Fueron estudiadas las CEO2 de 15 voluntarios, estado físico ASA I, sometidos a la técnica de oxigenación con ocho respiraciones profundas (capacidad vital en 60s con flujo de gas fresco de 10 L.min-1. La máscara facial fue bien acoplada con CIO2 del 100% (Ac100, variando del 50% a 90% (Ac50; Ac60; Ac70; Ac80; Ac90 y máscara acoplada por la gravedad y CIO2 100% (Grav; máscara a 1 cm de la faz y CIO2 a 100% (Afast. La CEO2 fue registrada en intervalos de 10s hasta 60s. En los tests estadísticos p BACKGROUND AND OBJECTIVES: Different oxygenation techniques aim at promoting denitrogenation before apnea during induction. The main reason why CIO2 = 100% cannot be reached is the lack of adequate face mask coupling, allowing the entry of room air. Although anesthesiologists know this principle, not all of them apply it correctly, facilitating the entry of air in fresh gases flow and consequently diluting CIO2. This prospective study was performed to comparatively evaluate, through the variation of oxygen expired concentration (CEO2, the efficacy of the oxygenation technique via face mask in the conditions routinely used by anesthesiologists, simulating situations of progressive leaks. METHODS: Oxygen end-tidal concentrations of 15 volunteers, physical status ASA I, were studied with 8 deep breaths (vital capacity in 60 s with fresh gas flow of 10 L.min-1. The face mask was: tightly fitted with 100% CIO2 (Tf100 or varying from 50% to 90%, (Tf50, Tf60, Tf70, Tf80, Tf90; gravity-coupled to face and 100% CIO2 (Grav and moved 1 cm away from face with 100% CIO2 (Aw. CEO2 was recorded at 10 s intervals. P < 0.05 was considered statistically significant. RESULTS: CEO2 has increased for all groups (p < 0.001, but only Tf100 reached values close to

  4. Attenuation of earmuffs used simultaneously with respiratory protective devices

    Directory of Open Access Journals (Sweden)

    Emil Kozłowski

    2017-06-01

    Full Text Available Background: In the work environment, apart from the noise, employees may be exposed to other harmful factors. Therefore, they wear hearing protectors and other personal protective equipment. The aim of the study was to determine whether simultaneous use of earmuffs and respiratory protective devices affects the attenuation of earmuffs. Material and Methods: The study was conducted in laboratory conditions using the subjective REAT (Real Ear Attenuation at Threshold and objective MIRE (Microphone in Real Ear methods. The REAT method was used to measure sound attenuation of earmuffs, while MIRE was used to determine changes in attenuation of earmuffs due to the use of other personal protective equipment. Results: The study showed reduction in attenuation of earmuffs due to the use of a full face mask up to 20 dB. Using a full face mask causes that attenuation of earmuffs in the low frequency range is close to zero. Reduction in attenuation due to the use of half masks for complete with particle filters (half masks is 3–15 dB. Simultaneous use of earmuffs and filtering half masks makes small changes in attenuation not exceeding 3 dB. Conclusions: The study showed that full face masks give the greatest reduction in attenuation of earmuffs. On the other hand, the least reduction is observed in the case of filtering half masks. There is a significant difference between the reduction in attenuation of earmuffs worn with half masks for complete with particle filters because they may be equipped with different kind of the head strap. Med Pr 2017;68(3:349–361

  5. venice: Mask utility

    Science.gov (United States)

    Coupon, Jean

    2018-02-01

    venice reads a mask file (DS9 or fits type) and a catalogue of objects (ascii or fits type) to create a pixelized mask, find objects inside/outside a mask, or generate a random catalogue of objects inside/outside a mask. The program reads the mask file and checks if a point, giving its coordinates, is inside or outside the mask, i.e. inside or outside at least one polygon of the mask.

  6. Evaluation of protection factor of respiratory protective equipment using indigenously developed protection factor test facility

    International Nuclear Information System (INIS)

    Patkulkar, D.S.; Ganesh, G.; Tripathi, R.M.

    2018-01-01

    Assigned protection factor (APF) is an indicator representing effectiveness of a respirator and it provides workplace level of respiratory protection for workers in providing protection against exposure to airborne contaminants Occupational Safety and Health Administration (OSHA) specifies 'Respirator APF' and 'Maximum Use Concentration' (MUC - a term derived using APF) shall be an integral part of Respirator Protection Standard. MUC establishes the maximum airborne concentration of a contaminant in which a respirator with a given APF may be used. The use of particulate respirators such as half face mask, full face mask and powered air purifying respirators is essential for radioactive jobs in nuclear facilities to prevent any intake of radionuclide. With this impetus, the Protection Factor Test Facility (PFTF) for testing and evaluation of respiratory protective equipment meeting relevant applicable standards was designed, fabricated and installed in Respiratory Protective Equipment Laboratory of Health Physics Division

  7. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, and... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall be designed and...

  8. Shadows alter facial expressions of Noh masks.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    Full Text Available BACKGROUND: A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. METHODOLOGY/PRINCIPAL FINDINGS: In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. CONCLUSIONS/SIGNIFICANCE: Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety", which highly appreciates subtle emotional expressions in the darkness.

  9. Quantified Faces

    DEFF Research Database (Denmark)

    Sørensen, Mette-Marie Zacher

    2016-01-01

    artist Marnix de Nijs' Physiognomic Scrutinizer is an interactive installation whereby the viewer's face is scanned and identified with historical figures. The American artist Zach Blas' project Fag Face Mask consists of three-dimensional portraits that blend biometric facial data from 30 gay men's faces...... and critically examine bias in surveillance technologies, as well as scientific investigations, regarding the stereotyping mode of the human gaze. The American artist Heather Dewey-Hagborg creates three-dimensional portraits of persons she has “identified” from their garbage. Her project from 2013 entitled...

  10. The relationship between bedding and face-down death in infancy: mathematical analysis of a respiratory simulation system using an infant mannequin to assess gas diffusibility in bedding.

    Science.gov (United States)

    Sakai, Jun; Funayama, Masato; Kanetake, Jun

    2007-02-14

    Rebreathing is a model for the relationship between a prone sleeping position and sudden infant death syndrome. This study used a mechanical simulation model to establish the relationship between types of bedding and rebreathing potential for an infant placed prone (face down) at different postnatal ages. The infant mannequin was connected to a respirator set to deliver physiologically appropriate combinations of tidal volume (V(T)) and respiratory rates (RR) across a range of postnatal ages (0-18 months). Before measurements were made, CO(2) flow was regulated to 5+/-0.1% of end-tidal PCO(2) (EtCO(2)). After the model was placed in a prone position, any increase in the fractional concentration of inspired CO(2) (FiCO(2)) was measured. FiCO(2) increased immediately and rapidly, and reached a maximum value within a few minutes. The maximum FiCO(2) ranged from under 2% to over 10%, depending on the bedding. FiCO(2) was also affected by V(T) and RR. This model is not applicable to actual infants because of the large tissue stores of CO(2) in infants; however, it is useful for evaluation of gas diffusibility of bedding and will simplify the investigation of sleeping environments when a baby is found dead with its face covered by soft bedding. In general, the higher the FiCO(2), the greater the rebreathing potential. Theoretically, considering the paucity of body stores of O(2), changes in FiO(2) would be affected not by changes in FiCO(2), but by CO(2) production and gas movement around the infant's face. The rapid decrease of FiO(2) is approximated at the inverse of the FiCO(2) timecourse, suggesting the significance of not only CO(2) accumulation but also O(2) deprivation in the potential space around the baby's face.

  11. Visual masking & schizophrenia

    Directory of Open Access Journals (Sweden)

    Michael H. Herzog

    2015-06-01

    Full Text Available Visual masking is a frequently used tool in schizophrenia research. Visual masking has a very high sensitivity and specificity and masking paradigms have been proven to be endophenotypes. Whereas masking is a powerful technique to study schizophrenia, the underlying mechanisms are discussed controversially. For example, for more than 25 years, masking deficits of schizophrenia patients were mainly attributed to a deficient magno-cellular system (M-system. Here, we show that there is very little evidence that masking deficits are magno-cellular deficits. We will discuss the magno-cellular and other approaches in detail and highlight their pros and cons.

  12. Respiratory analysis system and method

    Science.gov (United States)

    Liu, F. F. (Inventor)

    1973-01-01

    A system is described for monitoring the respiratory process in which the gas flow rate and the frequency of respiration and expiration cycles can be determined on a real time basis. A face mask is provided with one-way inlet and outlet valves where the gas flow is through independent flowmeters and through a mass spectrometer. The opening and closing of a valve operates an electrical switch, and the combination of the two switches produces a low frequency electrical signal of the respiratory inhalation and exhalation cycles. During the time a switch is operated, the corresponsing flowmeter produces electric pulses representative of the flow rate; the electrical pulses being at a higher frequency than that of the breathing cycle and combined with the low frequency signal. The high frequency pulses are supplied to conventional analyzer computer which also receives temperature and pressure inputs and computes mass flow rate and totalized mass flow of gas. From the mass spectrometer, components of the gas are separately computed as to flow rate. The electrical switches cause operation of up-down inputs of a reversible counter. The respective up and down cycles can be individually monitored and combined for various respiratory measurements.

  13. Binaural masking level differences in nonsimultanuous masking

    NARCIS (Netherlands)

    Kohlrausch, A.G.; Fassel, R.; Gilkey, R.H.; Anderson, T.R.

    1997-01-01

    This chapter investigates the extent to which binaural unmasking occurs with nonsimultaneous presentation of masker and signal, particularly in forward masking. The majority of previous studies that addressed this question found that there is a substantial binaural masking level difference (BMLD) in

  14. Shadows Alter Facial Expressions of Noh Masks

    Science.gov (United States)

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748

  15. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, mouthpieces... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall be...

  16. Masks in Pedagogical Practice

    Science.gov (United States)

    Roy, David

    2016-01-01

    In Drama Education mask work is undertaken and presented as both a methodology and knowledge base. There are numerous workshops and journal articles available for teachers that offer knowledge or implementation of mask work. However, empirical examination of the context or potential implementation of masks as a pedagogical tool remains…

  17. Keeping African Masks Real

    Science.gov (United States)

    Waddington, Susan

    2012-01-01

    Art is a good place to learn about our multicultural planet, and African masks are prized throughout the world as powerfully expressive artistic images. Unfortunately, multicultural education, especially for young children, can perpetuate stereotypes. Masks taken out of context lose their meaning and the term "African masks" suggests that there is…

  18. 2013 mask industry survey

    Science.gov (United States)

    Malloy, Matt

    2013-09-01

    A comprehensive survey was sent to merchant and captive mask shops to gather information about the mask industry as an objective assessment of its overall condition. 2013 marks the 12th consecutive year for this process. Historical topics including general mask profile, mask processing, data and write time, yield and yield loss, delivery times, maintenance, and returns were included and new topics were added. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. While each year's survey includes minor updates based on feedback from past years and the need to collect additional data on key topics, the bulk of the survey and reporting structure have remained relatively constant. A series of improvements is being phased in beginning in 2013 to add value to a wider audience, while at the same time retaining the historical content required for trend analyses of the traditional metrics. Additions in 2013 include topics such as top challenges, future concerns, and additional details in key aspects of mask masking, such as the number of masks per mask set per ground rule, minimum mask resolution shipped, and yield by ground rule. These expansions beyond the historical topics are aimed at identifying common issues, gaps, and needs. They will also provide a better understanding of real-life mask requirements and capabilities for comparison to the International Technology Roadmap for Semiconductors (ITRS).

  19. What's behind the mask? A look at blood flow changes with prolonged facial pressure and expression using laser Doppler imaging.

    Science.gov (United States)

    Van-Buendia, Lan B; Allely, Rebekah R; Lassiter, Ronald; Weinand, Christian; Jordan, Marion H; Jeng, James C

    2010-01-01

    Clinically, the initial blanching in burn scar seen on transparent plastic face mask application seems to diminish with time and movement requiring mask alteration. To date, studies quantifying perfusion with prolonged mask use do not exist. This study used laser Doppler imaging (LDI) to assess perfusion through the transparent face mask and movement in subjects with and without burn over time. Five subjects fitted with transparent face masks were scanned with the LDI on four occasions. The four subjects without burn were scanned in the following manner: 1) no mask, 2) mask on while at rest, 3) mask on with alternating intervals of sustained facial expression and rest, and 4) after mask removal. Images were acquired every 3 minutes throughout the 85-minute study period. The subject with burn underwent a shortened scanning protocol to increase comfort. Each face was divided into five regions of interest for analysis. Compared with baseline, mask application decreased perfusion significantly in all subjects (P mask removal, all regions of the face demonstrated a hyperemic effect with the chin (P = .05) and each cheek (P mask removal. Perfusions remain constantly low while wearing the face mask, despite changing facial expressions. Changing facial expressions with the mask on did not alter perfusion. Hyperemic response occurs on removal of the mask. This study exposed methodology and statistical issues worth considering when conducting future research with the face, pressure therapy, and with LDI technology.

  20. Emergency airway management with laryngeal mask airway

    African Journals Online (AJOL)

    2009-12-01

    Dec 1, 2009 ... management and as a ventilatory device during anesthesia. It is concluded that ... minutes with a tight fitting face mask and a closed system; and 0.6 mg of ... In the operating suite, intravenous access was secured and saline ...

  1. Traditional Chinese Masks Reveal Customs

    Institute of Scientific and Technical Information of China (English)

    1996-01-01

    CHINESE masks are undoubtedly an important component in the worldwide mask culture. Minority nationality masks are a major component of China’s mask culture. Traditional Chinese masks, or nuo, represent a cultural component which originated from religious rites in prehistoric times. Various types of nuo are highly valuable for studies of Chinese customs.

  2. How the global layout of the mask influences masking strength.

    Science.gov (United States)

    Ghose, Tandra; Hermens, Frouke; Herzog, Michael H

    2012-12-10

    In visual backward masking, the perception of a target is influenced by a trailing mask. Masking is usually explained by local interactions between the target and the mask representations. However, recently it has been shown that the global spatial layout of the mask rather than its local structure determines masking strength (Hermens & Herzog, 2007). Here, we varied the mask layout by spatial, luminance, and temporal cues. We presented a vernier target followed by a mask with 25 elements. Performance deteriorated when the length of the two mask elements neighboring the target vernier was doubled. However, when the length of every second mask element was doubled, performance improved. When the luminance of the neighboring elements was doubled, performance also deteriorated but no improvement in performance was observed when every second element had a double luminance. For temporal manipulations, a complex nonmonotonic masking function was observed. Hence, changes in the mask layout by spatial, luminance, and temporal cues lead to highly different results.

  3. Mask Phenomenon in Communication

    Institute of Scientific and Technical Information of China (English)

    郎丽璇

    2013-01-01

    People sometimes wear masks. Abusive expression may be used to convey love while polite words can be exchanged among enemies. This essay describes and discusses this special phenomenon in communication and analyzes the elements that con-tribute to the success of a mask communication.

  4. Binary Masking & Speech Intelligibility

    DEFF Research Database (Denmark)

    Boldt, Jesper

    The purpose of this thesis is to examine how binary masking can be used to increase intelligibility in situations where hearing impaired listeners have difficulties understanding what is being said. The major part of the experiments carried out in this thesis can be categorized as either experime......The purpose of this thesis is to examine how binary masking can be used to increase intelligibility in situations where hearing impaired listeners have difficulties understanding what is being said. The major part of the experiments carried out in this thesis can be categorized as either...... experiments under ideal conditions or as experiments under more realistic conditions useful for real-life applications such as hearing aids. In the experiments under ideal conditions, the previously defined ideal binary mask is evaluated using hearing impaired listeners, and a novel binary mask -- the target...... binary mask -- is introduced. The target binary mask shows the same substantial increase in intelligibility as the ideal binary mask and is proposed as a new reference for binary masking. In the category of real-life applications, two new methods are proposed: a method for estimation of the ideal binary...

  5. Mask materials in powderblasting

    NARCIS (Netherlands)

    Wensink, H.; Berenschot, Johan W.; Jansen, Henricus V.; Elwenspoek, Michael Curt

    1999-01-01

    Powderblasting has the opportunity to become a standard technology in micromachining. To machine small details with powderbalsting, it is necessary to use a suiabled mask. In this paper four mask types ares examined. BF400 resist foil is most suitable for standard use in powderblasting for reason of

  6. The Moody Mask Model

    DEFF Research Database (Denmark)

    Larsen, Bjarke Alexander; Andkjær, Kasper Ingdahl; Schoenau-Fog, Henrik

    2015-01-01

    This paper proposes a new relation model, called "The Moody Mask model", for Interactive Digital Storytelling (IDS), based on Franceso Osborne's "Mask Model" from 2011. This, mixed with some elements from Chris Crawford's Personality Models, is a system designed for dynamic interaction between ch...

  7. Comparison of the OxyMask and Venturi Mask in the Delivery of Supplemental Oxygen: Pilot Study in Oxygen-Dependent Patients

    Directory of Open Access Journals (Sweden)

    Jaime M Beecroft

    2006-01-01

    Full Text Available BACKGROUND: The OxyMask (Southmedic Inc, Canada is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA in patients with chronic hypoxemia.

  8. What's in a mask? Information masking with forward and backward visual masks.

    Science.gov (United States)

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  9. Hybrid mask for deep etching

    KAUST Repository

    Ghoneim, Mohamed T.

    2017-08-10

    Deep reactive ion etching is essential for creating high aspect ratio micro-structures for microelectromechanical systems, sensors and actuators, and emerging flexible electronics. A novel hybrid dual soft/hard mask bilayer may be deposited during semiconductor manufacturing for deep reactive etches. Such a manufacturing process may include depositing a first mask material on a substrate; depositing a second mask material on the first mask material; depositing a third mask material on the second mask material; patterning the third mask material with a pattern corresponding to one or more trenches for transfer to the substrate; transferring the pattern from the third mask material to the second mask material; transferring the pattern from the second mask material to the first mask material; and/or transferring the pattern from the first mask material to the substrate.

  10. 42 CFR 84.135 - Half-mask facepieces, full facepieces, hoods, and helmets; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, hoods, and... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.135 Half-mask facepieces, full facepieces, hoods, and helmets; fit; minimum requirements. (a) Half-mask facepieces and full facepieces shall...

  11. 42 CFR 84.198 - Half-mask facepieces, full facepieces, mouthpieces, hoods, and helmets; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, mouthpieces... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Chemical Cartridge Respirators § 84.198 Half-mask facepieces, full facepieces, mouthpieces, hoods, and helmets; fit; minimum requirements. (a) Half-mask facepieces...

  12. 2012 Mask Industry Survey

    Science.gov (United States)

    Malloy, Matt; Litt, Lloyd C.

    2012-11-01

    A survey supported by SEMATECH and administered by David Powell Consulting was sent to semiconductor industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. 2012 marks the 11th consecutive year for the mask industry survey. This year's survey and reporting structure are similar to those of the previous years with minor modifications based on feedback from past years and the need to collect additional data on key topics. Categories include general mask information, mask processing, data and write time, yield and yield loss, delivery times, and maintenance and returns. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. Results, initial observations, and key comparisons between the 2011 and 2012 survey responses are shown here, including multiple indications of a shift towards the manufacturing of higher end photomasks.

  13. Mask quality assessment

    Science.gov (United States)

    Regis, Larry; Paulson, Neil; Reynolds, James A.

    1994-02-01

    Product quality and timely delivery are two of the most important parameters, determining the success of a mask manufacturing facility. Because of the sensitivity of this data, however, very little is known about industry performance in these areas. Using Arthur Andersen & Co. to protect contributor identity, the authors have conducted a blind quality survey of mask shops which represents over 75% of the total merchant and captive mask volume in the US. Quantities such as return rate, plate survival yield, performance to schedule and reason for return were requested from 1988 through Q2 1993. Data is analyzed and conclusions are presented.

  14. Respiratory acidosis

    Science.gov (United States)

    Ventilatory failure; Respiratory failure; Acidosis - respiratory ... Causes of respiratory acidosis include: Diseases of the airways (such as asthma and COPD ) Diseases of the lung tissue (such as ...

  15. Masked Photocathode for Photoinjector

    International Nuclear Information System (INIS)

    Qiang, Ji

    2010-01-01

    In this research note, we propose a scheme to insert a photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto the electrode, a masked electrode with small hole is used to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material very simple by rotating the photocathode behind the mask into the hole. This will significantly increase the usage lifetime of a photocathode. Furthermore, this also helps reduce the dark current or secondary electron emission from the photocathode. The hole on the mask also provides a transverse cut-off to the Gaussian laser profile which can be beneficial from the beam dynamics point of view.

  16. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    Science.gov (United States)

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Masks: The Artist in Me

    Science.gov (United States)

    Skophammer, Karen

    2009-01-01

    Whether masks are made from cardboard, papier-mache, metal, wood, leather, fabric, clay or any combination of these materials, they bring out the artist in people. Young children like to wear masks when they play to pretend they were another person or animal. Masks let them fantasize and be creative. The author's students made masks representing…

  18. Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems

    Energy Technology Data Exchange (ETDEWEB)

    Leitzen, C.; Wilhelm-Buchstab, T.; Garbe, S.; Luetter, C.; Muedder, T.; Simon, B.; Schild, H.H.; Schueller, H. [Universitaetsklinik Bonn, Radiologische Klinik, FE Strahlentherapie, Bonn (Germany)

    2014-04-15

    Patient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. Thirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal {sup registered} or Open Face {sup registered} mask, Orfit) or the standard three-point mask (Raycast {sup registered} -HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation. The mean values of the table adjustments were: (a) lateral (mm): -0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); -0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): -1 (mask 1, σ: 2.57); -0.5 (mask 2, σ: 4.7); -1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35 (mask 1, σ: 0.75); 0 (mask 2, σ: 0.8); 0.02 (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5 (roll). There were no significant differences between the groups. The new mask systems improve patient comfort while providing consistent patient positioning. (orig.)

  19. Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems

    International Nuclear Information System (INIS)

    Leitzen, C.; Wilhelm-Buchstab, T.; Garbe, S.; Luetter, C.; Muedder, T.; Simon, B.; Schild, H.H.; Schueller, H.

    2014-01-01

    Patient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. Thirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal registered or Open Face registered mask, Orfit) or the standard three-point mask (Raycast registered -HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation. The mean values of the table adjustments were: (a) lateral (mm): -0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); -0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): -1 (mask 1, σ: 2.57); -0.5 (mask 2, σ: 4.7); -1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35 (mask 1, σ: 0.75); 0 (mask 2, σ: 0.8); 0.02 (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5 (roll). There were no significant differences between the groups. The new mask systems improve patient comfort while providing consistent patient positioning. (orig.)

  20. Non-invasive measure of respiratory mechanics and conventional respiratory parameters in conscious large animals by high frequency Airwave Oscillometry.

    Science.gov (United States)

    Bassett, Leanne; Troncy, Eric; Robichaud, Annette; Schuessler, Thomas F; Pouliot, Mylène; Ascah, Alexis; Authier, Simon

    2014-01-01

    A number of drugs in clinical trials are discontinued due to potentially life-threatening airway obstruction. As some drugs may not cause changes in core battery parameters such as tidal volume (Vt), respiratory rate (RR) or minute ventilation (MV), including measurements of respiratory mechanics in safety pharmacology studies represents an opportunity for design refinement. The present study aimed to test a novel non-invasive methodology to concomitantly measure respiratory system resistance (Rrs) and conventional respiratory parameters (Vt, RR, MV) in conscious Beagle dogs and cynomolgus monkeys. An Airwave Oscillometry system (tremoFlo; THORASYS Inc., Montreal, Canada) was used to concomitantly assess Rrs and conventional respiratory parameters before and after intravenous treatment with a bronchoactive agent. Respiratory mechanics measurements were performed by applying a short (i.e. 16s) single high frequency (19Hz) waveform at the subject's airway opening via a face mask. During measurements, pressure and flow signals were recorded. After collection of baseline measurements, methacholine was administered intravenously to Beagle dogs (n=6) and cynomolgus monkeys (n=4) at 8 and 68μg/kg, respectively. In dogs, methacholine induced significant increases in Vt, RR and MV while in monkeys, it only augmented RR. A significant increase in Rrs was observed after methacholine administration in both species with mean percentage peak increases from baseline of 88 (53)% for dogs and 28 (16)% for cynomolgus monkeys. Airwave Oscillometry appears to be a promising non-invasive methodology to enable respiratory mechanics measurements in conscious large animals, a valuable refinement in respiratory safety pharmacology. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Orion Emergency Mask Approach

    Science.gov (United States)

    Tuan, George C.; Graf, John C.

    2009-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction time, breakthroughs, and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  2. Face Attention Network: An Effective Face Detector for the Occluded Faces

    OpenAIRE

    Wang, Jianfeng; Yuan, Ye; Yu, Gang

    2017-01-01

    The performance of face detection has been largely improved with the development of convolutional neural network. However, the occlusion issue due to mask and sunglasses, is still a challenging problem. The improvement on the recall of these occluded cases usually brings the risk of high false positives. In this paper, we present a novel face detector called Face Attention Network (FAN), which can significantly improve the recall of the face detection problem in the occluded case without comp...

  3. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    Science.gov (United States)

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, Pmask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  5. Emergency respiratory protection with common materials

    International Nuclear Information System (INIS)

    Cooper, D.W.; Hinds, W.C.; Price, J.M.

    1983-01-01

    Certain unexpected accidents, such as fires, explosions, chemical spills, or nuclear reactor malfunctions, can lead to the exposure of workers and the public to toxic gases, vapors, and aerosols. The efficacy of readily available materials, such as cotton fabric, toweling, and a single-use respirator, for providing emergency respiratory protection was evaluated by determining the filtration efficiency as a function of particle size over the range of 0.4 to 5 μm diameter and performance against a reactive water soluble (I 2 ) and unreactive vapor (CH 3 I). At a reasonable design face velocity (1.5 cm/s), the respirator mask used at double thickness could reduce particle concentrations a factor of 30 or more throughout the particle range tested, and a wetted towel four layers thick could provide a factor of five. Dry fabrics were ineffective in removing iodine vapor, but wetted sheeting or toweling reduced concentration by a factor of ten or more under design conditions, 1.5 cm/s face velocity and 50 Pa pressure drop (0.2 inches of water). The fabrics provided a statistically insignificant reduction in methyliodide. In practice, any leaks around the seal to the face would lessen the protection offered by such materials. The effectiveness factor approach proved useful in comparing filter performance under different conditions

  6. Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking

    Science.gov (United States)

    Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.

    2011-01-01

    In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…

  7. Acute exposure to realistic acid fog: effects on respiratory function and airway responsiveness in asthmatics.

    OpenAIRE

    Leduc, Dimitri; Fally, Sophie; De Vuyst, Paul; Wollast, Roland; Yernault, Jean Claude

    1995-01-01

    Naturally occurring fogs in industrialized cities are contaminated by acidic air pollutants. In Brussels, Belgium, the pH of polluted fogwater may be as low as 3 with osmolarity as low as 30 mOsm. In order to explore short-term respiratory effects of a realistic acid-polluted fog, we collected samples of acid fog in Brussels, Belgium, which is a densely populated and industrialized city, we defined characteristics of this fog and exposed asthmatic volunteers at rest through a face mask to fog...

  8. Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head; Verbesserte lagerungsreproduzierbarkeit eines nichtinvasiven hochpraezisionsmaskensystems in der stereotaktischen Radiotherapie durch eine integrierte kieferfixierung

    Energy Technology Data Exchange (ETDEWEB)

    Lopatta, E.; Liesenfeld, S.M.; Bank, P.; Guenther, R.; Wiezorek, T.; Wendt, T.G. [Klinik fuer Radiologie, Abt. fuer Strahlentherapie, Friedrich-Schiller-Univ. Jena (Germany); Wurm, R. [Campus Charite Mitte, Klinik fuer Strahlentherapie, Berlin (Germany)

    2003-08-01

    Background: For high precision radiotherapy of the neurocranium a precise, reproducible positioning technique is the basic pre-requisite. The aim of this study was to assess the influence of a modification of the commercially available stereotactical BrainLab {sup trademark} -head mask system on accuracy in patient positioning during fractionated radiotherapy. Material and Methods: 29 patients were treated with stereotactic radiotherapy of the head. Immobilization was provided by a two layer thermoplastic mask system (BrainLab trademark). 18 of these patients received an additional custom made fixation either of the upper jaw (OKF) or of the mandibula (UKF). The positioning accuracy was assessed by measurements of the shifting of anatomical landmarks in relation to therigid mask system on biplanar simulator films using a digital imaging system. Before each measurement a fine adjustment of the simulator to an optical ring system was performed. The reference radiographs were done just before CT-planning. During a 2-7 weeks lasting course of radiotherapy displacement measurements in relation to the reference images for all three dimensions (z, y and x) were done once a week. In 29 patients 844 measurements were analyzed. Results: An additional jaw fixation improves the reproducibility of patient positioning significantly in all three spatial dimensions. The standard deviation in lateral direction (x) was 0.6 mm with jaw fixation vs. 0.7 mm without jaw fixation (p < 0.001); in longitudinal direction (z) (measured in 0 radiographs) 0.5 mm vs. 1.3 mm (p < 0.001); in longitudinal direction measured in 90 (orig.) [German] Hintergrund: Eine Grundvoraussetzung fuer die Praezisionsbestrahlung im Bereich des Neurokraniums ist eine genaue, reproduzierbare Lagerungstechnik. Die vorliegende Arbeit untersucht den Einfluss einer Modifikation am kommerziell erhaeltlichen stereotaktischen BrainLab trademark -Kopfmaskensystem auf die Lagerungsgenauigkeit waehrend einer fraktionierten

  9. Filtration of nanoparticles - Application to respiratory protecting devices

    International Nuclear Information System (INIS)

    Brochot, C.

    2012-01-01

    This study aims to determine how the respiratory protective devices (RPD), whose performances are qualified for particles above 100 nm, are effective for nanoparticles. Indeed, if the use of a collective filtration is inadequate, wearing a RPD is the last protection recommended. A literature review showed that no research concerned the effectiveness of half-masks for nanoparticles. The test bench ETNA has been sized and built to overcome these lacks. Two half masks were tested according to different configurations: constant flow rate and cyclic flow rate (average flow of 84 L /min), particle size (from 5 to 100 nm), positions of the mask (sealed, usual, or with calibrated leaks). The results show that, since the RPD contain high efficiency filter media (without charged fibers) for the most penetrating particle size (100 nm - 300 nm), the RPD is more efficient for nanoparticles. Furthermore, the results obtained in the presence of actual and calibrated leaks, highlighted the importance of face seal leakages in determining the performance of RPD. A model for calculating the protection factor was established based on the balance between the airflow through the filter and the leak. This model was validated using measurements obtained in the presence of calibrated leaks, and applied for the analysis of our results in usual position. (author)

  10. Non-invasive mechanical ventilation after the successful weaning: a comparison with the venturi mask

    Directory of Open Access Journals (Sweden)

    Esra Adıyeke

    Full Text Available Abstract Background and objectives: This study compared the rates of acute respiratory failure, reintubation, length of intensive care stay and mortality in patients in whom the non-invasive mechanical ventilation (NIMV was applied instead of the routine venturi face mask (VM application after a successful weaning. Methods: Following the approval of the hospital ethics committee, 62 patients who were under mechanical ventilation for at least 48 hours were scheduled for this study. 12 patients were excluded because of the weaning failure during T-tube trial. The patients who had optimum weaning criteria after the T-tube trial of 30 minutes were extubated. The patients were kept on VM for 1 hour to observe the hemodynamic and respiratory stability. The group of 50 patients who were successful to wean randomly allocated to have either VM (n = 25, or NIV (n = 25. Systolic arterial pressure (SAP, heart rate (HR, respiratory rate (RR, PaO2, PCO2, and pH values were recorded. Results: The number of patients who developed respiratory failure in the NIV group was significantly less than VM group of patients (3 reintubation vs. 14 NIV + 5 reintubation in the VM group. The length of stay in the ICU was also significantly shorter in NIV group (5.2 ± 4.9 vs. 16.7 ± 7.7 days. Conclusions: The ratio of the respiratory failure and the length of stay in the ICU were lower when non-invasive mechanical ventilation was used after extubation even if the patient is regarded as ‘successfully weaned’. We recommend the use of NIMV in such patients to avoid unexpected ventilator failure.

  11. Respiratory alkalosis

    Science.gov (United States)

    Alkalosis - respiratory ... leads to shortness of breath can also cause respiratory alkalosis (such as pulmonary embolism and asthma). ... Treatment is aimed at the condition that causes respiratory alkalosis. Breathing into a paper bag -- or using ...

  12. The difficult business model for mask equipment makers and mask infrastructure development support from consortia and governments

    Science.gov (United States)

    Hector, Scott

    2005-11-01

    The extension of optical projection lithography through immersion to patterning features with half pitch face the challenge of being profitable in the small market for mask equipment while encountering significant R&D expenses to bring new generations of mask fabrication equipment to market. The total available market for patterned masks is estimated to be $2.5B to $2.9B per year. The patterned mask market is about 20% of the market size for lithography equipment and materials. The total available market for mask-making equipment is estimated to be about $800M per year. The largest R&D affordability issue arises for the makers of equipment for fabricating masks where total available sales are typically less than ten units per year. SEMATECH has used discounted cash flow models to predict the affordable R&D while maintaining industry accepted internal rates of return. The results have been compared to estimates of the total R&D cost to bring a new generation of mask equipment to market for various types of tools. The analysis revealed that affordability of the required R&D is a significant problem for many suppliers of mask-making equipment. Consortia such as SEMATECH and Selete have played an important role in cost sharing selected mask equipment and material development projects. Governments in the United States, in Europe and in Japan have also helped equipment suppliers with support for R&D. This paper summarizes the challenging business model for mask equipment suppliers and highlight government support for mask equipment and materials development.

  13. Control and prevention of healthcare-associated tuberculosis: the role of respiratory isolation and personal respiratory protection.

    Science.gov (United States)

    Humphreys, H

    2007-05-01

    Although the prevalence of tuberculosis continues to decline in most developed countries, the risk of healthcare-associated tuberculosis, remains for patients or healthcare staff. Outbreaks of healthcare-associated tuberculosis are usually associated with delays in diagnosis and treatment, or the care of patients in sub-optimal facilities. The control and prevention of tuberculosis in hospitals is best achieved by three approaches, namely administrative (early investigation diagnosis, etc.), engineering (physical facilities e.g. ventilated isolation rooms) and personal respiratory protection (face sealing masks which are filtered). Recent guidelines on the prevention of tuberculosis in healthcare facilities from Europe and the USA have many common themes. In the UK, however, negative pressure isolation rooms are recommended only for patients with suspected multi-drug resistant TB and personal respiratory protection, i.e. filtered masks, are not considered necessary unless multi-drug resistant TB is suspected, or where aerosol-generating procedures are likely. In the US, the standard of care for patients with infectious tuberculosis is a negative pressure ventilated room and the use of personal respiratory protection for all healthcare workers entering the room of a patient with suspected or confirmed tuberculosis. The absence of clinical trials in this area precludes dogmatic recommendations. Nonetheless, observational studies and mathematical modelling suggest that all measures are required for effective prevention. Even when policies and facilities are optimal, there is a need to regularly review and audit these as sometimes compliance is less than optimal. The differences in recommendations may reflect the variations in epidemiology and the greater use of BCG vaccination in the UK compared with the United States. There is a strong argument for advising ventilated facilities and personal respiratory protection for the care of all patients with tuberculosis, as

  14. Migration from full‐head mask to “open‐face” mask for immobilization of patients with head and neck cancer

    Science.gov (United States)

    Lovelock, D. Michael; Mechalakos, James; Rao, Shyam; Della‐Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-01-01

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an “open‐face” thermoplastic mask was evaluated using video‐based optical surface imaging (OSI) and kilovoltage (kV) X‐ray radiography. A three‐point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real‐time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15 minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open‐face and full‐head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open‐face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real‐time OSI. With the open‐face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre‐/post‐treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask‐locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open‐face and full‐head masks were found to be similar. Most (80%) of the volunteers preferred the open‐face mask to the full‐head mask, while claustrophobic patients could only tolerate the open‐face mask. The open‐face mask is characterized for its immobilization capability and can immobilize patients sufficiently (face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full‐head mask. PACS numbers: 87.19.xj, 87.63.L‐, 87.59.‐e, 87.55.tg, 87.55.‐x PMID:24036878

  15. Mask industry quality assessment

    Science.gov (United States)

    Strott, Al; Bassist, Larry

    1994-12-01

    Product quality and timely delivery are two of the most important parameters in determining the success of a mask manufacturing facility. Because of the sensitivity of this data, very little was known about industry performance in these areas until an assessment was authored and presented at the 1993 BACUS Symposium by Larry Regis of Intel Corporation, Neil Paulsen of Intel Corporation, and James A. Reynolds of Reynolds Consulting. This data has been updated and will be published and presented at this year's BACUS Symposium. Contributor identities will again remain protected by utilizing Arthur Andersen & Company to compile the submittals. Participation was consistent with last year's representation of over 75% of the total merchant and captive mask volume in the United States. The data compiled includes shipments, customer return rate, customer return reasons from 1988 through Q2, 1994, performance to schedule, plate survival yield, and throughput time (TPT).

  16. Mask strategy at International SEMATECH

    Science.gov (United States)

    Kimmel, Kurt R.

    2002-08-01

    International SEMATECH (ISMT) is a consortium consisting of 13 leading semiconductor manufacturers from around the globe. Its objective is to develop the infrastructure necessary for its member companies to realize the International Technology Roadmap for Semiconductors (ITRS) through efficiencies of shared development resources and knowledge. The largest area of effort is lithography, recognized as a crucial enabler for microelectronics technology progress. Within the Lithography Division, most of the efforts center on mask-related issues. The development strategy at International SEMATCH will be presented and the interlock of lithography projects clarified. Because of the limited size of the mask production equipment market, the business case is weak for aggressive investment commensurate with the pace of the International Technology Roadmap for Semiconductors. With masks becoming the overwhelming component of lithography cost, new ways of reducing or eliminating mask costs are being explored. Will mask technology survive without a strong business case? Will the mask industry limit the growth of the semiconductor industry? Are advanced masks worth their escalating cost? An analysis of mask cost from the perspective of mask value imparted to the user is presented with examples and generic formulas for the reader to apply independently. A key part to the success for both International SEMATECH and the industry globally will be partnerships on both the local level between mask-maker and mask-user, and the macro level where global collaborations will be necessary to resolve technology development cost challenges.

  17. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    Science.gov (United States)

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  18. The prevalence and preventive measures of the respiratory illness among Malaysian pilgrims in 2013 Hajj season.

    Science.gov (United States)

    Hashim, Suhana; Ayub, Zeti N; Mohamed, Zeehaida; Hasan, Habsah; Harun, Azian; Ismail, Nabilah; Rahman, Zaidah A; Suraiya, Siti; Naing, Nyi Nyi; Aziz, Aniza A

    2016-02-01

    Respiratory illness continues to exert a burden on hajj pilgrims in Makkah. The purpose of this study is to determine the prevalence of respiratory illness and its associated factors among Malaysian hajj pilgrims in 2013 and to describe its preventive measures. A cross-sectional study was conducted in Makkah and Malaysia during the 2013 hajj season. A self-administered proforma on social demographics, previous experience of hajj or umrah, smoking habits, co-morbid illness and practices of preventive measures against respiratory illness were obtained. A total of 468 proforma were analysed. The prevalence of the respiratory illness was 93.4% with a subset of 78.2% fulfilled the criteria for influenza-like illness (ILI). Most of them (77.8%) had a respiratory illness of food supplement. Malaysian hajj pilgrims with previous experience of hajj (OR 0.24; 95% CI 0.10-0.56) or umrah (OR 0.19; 95% CI 0.07-0.52) and those who have practiced good hand hygiene (OR 0.35; 95% CI 0.16-0.79) were found to be significantly associated with lower risk of having respiratory illness. Otherwise, pilgrims who had contact with those with respiratory illness (OR 2.61; 95% CI 1.12-6.09) was associated with higher risk. The prevalence of respiratory illness remains high among Malaysian hajj pilgrims despite having some practices of preventive measures. All preventive measures which include hand hygiene, wearing face masks and influenza vaccination must be practiced together as bundle of care to reduce respiratory illness effectively. © The Author 2016. Published by Oxford University Press on behalf of International society of travel medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Mask fabrication process

    Science.gov (United States)

    Cardinale, Gregory F.

    2000-01-01

    A method for fabricating masks and reticles useful for projection lithography systems. An absorber layer is conventionally patterned using a pattern and etch process. Following the step of patterning, the entire surface of the remaining top patterning photoresist layer as well as that portion of an underlying protective photoresist layer where absorber material has been etched away is exposed to UV radiation. The UV-exposed regions of the protective photoresist layer and the top patterning photoresist layer are then removed by solution development, thereby eliminating the need for an oxygen plasma etch and strip and chances for damaging the surface of the substrate or coatings.

  20. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  1. Mask alignment system for semiconductor processing

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.; Weaver, William T.; Grant, Christopher N.

    2017-02-14

    A mask alignment system for providing precise and repeatable alignment between ion implantation masks and workpieces. The system includes a mask frame having a plurality of ion implantation masks loosely connected thereto. The mask frame is provided with a plurality of frame alignment cavities, and each mask is provided with a plurality of mask alignment cavities. The system further includes a platen for holding workpieces. The platen may be provided with a plurality of mask alignment pins and frame alignment pins configured to engage the mask alignment cavities and frame alignment cavities, respectively. The mask frame can be lowered onto the platen, with the frame alignment cavities moving into registration with the frame alignment pins to provide rough alignment between the masks and workpieces. The mask alignment cavities are then moved into registration with the mask alignment pins, thereby shifting each individual mask into precise alignment with a respective workpiece.

  2. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies.

    Science.gov (United States)

    Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T

    2015-01-01

    Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic "face" surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. To compare mask to "face" seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the "face." Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. The soft "face" significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft "face" was significantly greater for the SM compared to the AC (pmasks was observed with the hard "face." The material and pliability of the model "face" surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies.

  3. Akathisia masked by hypokinesia.

    Science.gov (United States)

    Tuisku, K; Lauerma, H; Holi, M M; Honkonen, T; Rimon, R

    2000-07-01

    Here, we will discuss the concept of subjective akathisia and present a patient case. Our patient was suffering from neuroleptic-induced hypokinesia and akathisia at the same time. The typical motor manifestations of akathisia were masked by hypokinesia, which made the diagnosis difficult. However, the subjective symptoms of akathisia were evident and distressing. Although not observable to bare eye, the pathognomonic pattern of motor activity detected in akathisia was demonstrated by actometric recording. Changing the conventional neuroleptic to an atypical one brought relief to the subjective symptoms of akathisia and hypokinesia, while the motor activity was clearly diminished in actometric recording. Actometric recording may be useful in diagnosing akathisia masked by hypokinesia, but the typical subjective symptoms of akathisia should not be ignored, even when actometry is not available to demonstrate the missing motor component of akathisia. Not only akathisia defined by DSM-IV but also subjective akathisia should be adequately treated to relieve the subjective distress, and to diminish the unfavorable effects on psychotic symptoms, behavior, and drug compliance.

  4. A survey of practice patterns in the use of laryngeal mask by pediatric anesthesiologists.

    Science.gov (United States)

    Patel, Anuradha; Clark, Scott R; Schiffmiller, Moshe; Schoenberg, Catherine; Tewfik, George

    2015-11-01

    Laryngeal mask is frequently the airway device of choice in routine general anesthesia for many procedures in children. Several studies have described the use of laryngeal masks in unconventional situations. This survey was undertaken to assess how laryngeal masks are being used by pediatric anesthesiologists. The 40-question electronic survey using SurveyMonkey™ was sent to 2740 members of the Society for Pediatric Anesthesia (SPA). This survey assessed the age, work environment, types of practice, and training levels, as well as clinical situations in which the practitioners use laryngeal masks across different pediatric age groups. Seven hundred and forty-three (27.1%) responses were obtained. The use of laryngeal mask increased as the patient age increased in nearly every queried situation. The practitioners routinely utilize laryngeal masks in a variety of challenging scenarios, such as in patients with a recent upper respiratory infection, in the difficult airway, remote locations, and long-duration surgeries. A small percentage of pediatric anesthesiologists use laryngeal masks in laparoscopic surgery and prone position procedures. Pediatric anesthesiologists are using laryngeal masks in both routine and challenging/unconventional situations. Although many of the uses for laryngeal masks are not explicitly stated in the manufacturer guidelines, literature and current practice support the use of laryngeal masks in several of these scenarios. © 2015 John Wiley & Sons Ltd.

  5. Pulmonary fibrosis secondary to siderosis causing symptomatic respiratory disease: a case report.

    Science.gov (United States)

    McCormick, Liam M; Goddard, Martin; Mahadeva, Ravi

    2008-08-05

    Pulmonary siderosis secondary to the inhalation of iron compounds is a rare condition which, despite striking radiological and histopathological features, has not traditionally been associated with symptoms or functional impairment. Although not the first of its kind, we present an unusual case of pulmonary siderosis with symptomatic respiratory disease, most likely secondary to associated fibrosis. A 66-year-old Caucasian man was referred to the outpatient clinic with a 2-year history of exertional breathlessness. He had worked as an engineer for 20 years where he did a significant amount of welding but always wore a face shield. Clinical, radiological and histological features were consistent with a diagnosis of pulmonary siderosis, with associated fibrosis, most likely related to his occupational welding history. Our report illustrates that symptomatic respiratory disease due to mild peribronchiolar fibrosis can occur with pulmonary siderosis despite wearing a mask. Furthermore, it reinforces the need for all clinicians to compile a detailed occupational history in individuals presenting with breathlessness.

  6. Mask Making: The Use of the Expressive Arts in Leadership Development.

    Science.gov (United States)

    Jones, Angela Thomas

    1992-01-01

    Outdoor educators in training engaged in a mask-making activity involving partners. One person made the mask and the other provided his or her face as the mold. The anxiety-provoking experience invited an intimate exchange between partners around issues of intimacy, trust, and compassion. (KS)

  7. The implementation of Mask-Ed: reflections of academic participants.

    Science.gov (United States)

    Reid-Searl, Kerry; Levett-Jones, Tracy; Cooper, Simon; Happell, Brenda

    2014-09-01

    This paper profiles the findings from a study that explored the perspectives and experiences of nurse educators who implemented a novel simulation approach termed Mask-Ed. The technique involves the educator wearing a silicone mask and or body parts and transforming into a character. The premise of this approach is that the masked educator has domain specific knowledge related to the simulation scenario and can transmit this to learners in a way that is engaging, realistic, spontaneous and humanistic. Nurse educators charged with the responsibility of implementing Mask-Ed in three universities were invited to participate in the study by attending an introductory workshop, implementing the technique and then journaling their experiences, insights and perspectives over a 12 month period. The journal entries were then thematically analysed. Key themes were categorised under the headings of Preparation, Implementation and Impact; Reflexivity and Responsiveness; Student Engagement and Ownership; and Teaching and Learning. Mask-Ed is a simulation approach which allows students to interact with the 'characters' in humanistic ways that promote person-centred care and therapeutic communication. This simulation approach holds previously untapped potential for a range of learning experiences, however, to be effective, adequate resourcing, training, preparation and practice is required. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. SEMATECH EUVL mask program status

    Science.gov (United States)

    Yun, Henry; Goodwin, Frank; Huh, Sungmin; Orvek, Kevin; Cha, Brian; Rastegar, Abbas; Kearney, Patrick

    2009-04-01

    As we approach the 22nm half-pitch (hp) technology node, the industry is rapidly running out of patterning options. Of the several lithography techniques highlighted in the International Technology Roadmap for Semiconductors (ITRS), the leading contender for the 22nm hp insertion is extreme ultraviolet lithography (EUVL). Despite recent advances with EUV resist and improvements in source power, achieving defect free EUV mask blank and enabling the EUV mask infrastructure still remain critical issues. To meet the desired EUV high volume manufacturing (HVM) insertion target date of 2013, these obstacles must be resolved on a timely bases. Many of the EUV mask related challenges remain in the pre-competitive stage and a collaborative industry based consortia, such as SEMATECH can play an important role to enable the EUVL landscape. SEMATECH based in Albany, NY is an international consortium representing several of the largest manufacturers in the semiconductor market. Full members include Intel, Samsung, AMD, IBM, Panasonic, HP, TI, UMC, CNSE (College of Nanoscience and Engineering), and Fuller Road Management. Within the SEMATECH lithography division a major thrust is centered on enabling the EUVL ecosystem from mask development, EUV resist development and addressing EUV manufacturability concerns. An important area of focus for the SEMATECH mask program has been the Mask Blank Development Center (MBDC). At the MBDC key issues in EUV blank development such as defect reduction and inspection capabilities are actively pursued together with research partners, key suppliers and member companies. In addition the mask program continues a successful track record of working with the mask community to manage and fund critical mask tools programs. This paper will highlight recent status of mask projects and longer term strategic direction at the MBDC. It is important that mask technology be ready to support pilot line development HVM by 2013. In several areas progress has been

  9. Respiratory Failure

    Science.gov (United States)

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, ... brain, need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can' ...

  10. Respiratory system

    Science.gov (United States)

    Bartlett, R. G., Jr.

    1973-01-01

    The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.

  11. SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

    International Nuclear Information System (INIS)

    Zhao, B; Maquilan, G; Anders, M; Jiang, S; Schwartz, D

    2016-01-01

    Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study

  12. SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Maquilan, G; Anders, M; Jiang, S; Schwartz, D [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study

  13. The efficacy of three different mask styles on a PAP titration night.

    Science.gov (United States)

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Barriers to mask wearing for influenza-like illnesses among urban Hispanic households.

    Science.gov (United States)

    Ferng, Yu-hui; Wong-McLoughlin, Jennifer; Barrett, Angela; Currie, Leanne; Larson, Elaine

    2011-01-01

    To identify barriers to mask wearing and to examine the factors associated with the willingness to wear masks among households. We used data sources from a study assessing the impact of 3 nonpharmaceutical interventions on the rates of influenza: exit interviews; home visits with a subset of the mask group; and a focus group. Risk perception score, univariate analysis, and logistic regression were conducted to identify the characteristics and predictors of mask use. Thematic barriers to mask wearing were identified from qualitative data obtained at home visits and focus group. Respondents from the mask group, when compared with the nonmask group, demonstrated higher risk perception scores concerning influenza (maximum score: 60, means: 37.6 and 30.2, pmask wearing (maximum score: 10, means: 7.8 and 7.3, p=.043). There was no significant association between demographic, attitudinal, or knowledge variables and adherence to wearing masks. Thematic barriers were identified such as social acceptability of mask use, comfort and fit, and perception of the risk/need for masks. Face masks may not be an effective intervention for seasonal or pandemic influenza unless the risk perception of influenza is high. Dissemination of culturally appropriate mask use information by health authorities and providers must be emphasized when educating the public. © 2010 Wiley Periodicals, Inc.

  15. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    Science.gov (United States)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  16. Masked rat: an x-ray-induced mutant with chronic blepharitis, alopecia, and pasteurellosis

    International Nuclear Information System (INIS)

    Kent, R.L.; Lutzner, M.A.; Hansen, C.T.

    1976-01-01

    An autosomal recessive mutation had been previously x-ray-induced in the rat and named the masked rat (genotype mk/mk). This study describes the mutant's appearance, histology, and microflora. The rat's eyelids were swollen, often to the point of closure, and its face was partially covered by a brownish crust, giving the mutant a mask-like appearance. The chronic blepharitis was also accompanied by alopecia that appeared as bare patches across the mutant's back. Pasteurella pneumotropica was found in eyelids and on skin from all masked rats. The normal rat demonstrated a resistance to Pasteurella pneumotropica infection, or, conversely, the masked rat appeared to be genetically predisposed to pasteurellosis

  17. Comparison of performance of three different types of respiratory protection devices.

    Science.gov (United States)

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both

  18. EUV mask manufacturing readiness in the merchant mask industry

    Science.gov (United States)

    Green, Michael; Choi, Yohan; Ham, Young; Kamberian, Henry; Progler, Chris; Tseng, Shih-En; Chiou, Tsann-Bim; Miyazaki, Junji; Lammers, Ad; Chen, Alek

    2017-10-01

    As nodes progress into the 7nm and below regime, extreme ultraviolet lithography (EUVL) becomes critical for all industry participants interested in remaining at the leading edge. One key cost driver for EUV in the supply chain is the reflective EUV mask. As of today, the relatively few end users of EUV consist primarily of integrated device manufactures (IDMs) and foundries that have internal (captive) mask manufacturing capability. At the same time, strong and early participation in EUV by the merchant mask industry should bring value to these chip makers, aiding the wide-scale adoption of EUV in the future. For this, merchants need access to high quality, representative test vehicles to develop and validate their own processes. This business circumstance provides the motivation for merchants to form Joint Development Partnerships (JDPs) with IDMs, foundries, Original Equipment Manufacturers (OEMs) and other members of the EUV supplier ecosystem that leverage complementary strengths. In this paper, we will show how, through a collaborative supplier JDP model between a merchant and OEM, a novel, test chip driven strategy is applied to guide and validate mask level process development. We demonstrate how an EUV test vehicle (TV) is generated for mask process characterization in advance of receiving chip maker-specific designs. We utilize the TV to carry out mask process "stress testing" to define process boundary conditions which can be used to create Mask Rule Check (MRC) rules as well as serve as baseline conditions for future process improvement. We utilize Advanced Mask Characterization (AMC) techniques to understand process capability on designs of varying complexity that include EUV OPC models with and without sub-resolution assist features (SRAFs). Through these collaborations, we demonstrate ways to develop EUV processes and reduce implementation risks for eventual mass production. By reducing these risks, we hope to expand access to EUV mask capability for

  19. Oxytocin Attenuates Neural Reactivity to Masked Threat Cues from the Eyes

    OpenAIRE

    Kanat, Manuela; Heinrichs, Markus; Schwarzwald, Ralf; Domes, Gregor

    2014-01-01

    The neuropeptide oxytocin has recently been shown to modulate covert attention shifts to emotional face cues and to improve discrimination of masked facial emotions. These results suggest that oxytocin modulates facial emotion processing at early perceptual stages prior to full evaluation of the emotional expression. Here, we used functional magnetic resonance imaging to examine whether oxytocin alters neural responses to backwardly masked angry and happy faces while controlling for attention...

  20. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    Incremental exercise test performance with and without a respiratory gas collection system. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  1. Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask.

    Science.gov (United States)

    Jannu, Anubhav; Shekar, Ashim; Balakrishna, Ramdas; Sudarshan, H; Veena, G C; Bhuvaneshwari, S

    2017-12-01

    The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

  2. Masks for extreme ultraviolet lithography

    International Nuclear Information System (INIS)

    Cardinale, G; Goldsmith, J; Kearney, P A; Larson, C; Moore, C E; Prisbrey, S; Tong, W; Vernon, S P; Weber, F; Yan, P-Y.

    1998-01-01

    In extreme ultraviolet lithography (EUVL), the technology specific requirements on the mask are a direct consequence of the utilization of radiation in the spectral region between 10 and 15 nm. At these wavelengths, all condensed materials are highly absorbing and efficient radiation transport mandates the use of all-reflective optical systems. Reflectivity is achieved with resonant, wavelength-matched multilayer (ML) coatings on all of the optical surfaces - including the mask. The EUV mask has a unique architecture - it consists of a substrate with a highly reflective ML coating (the mask blank) that is subsequently over-coated with a patterned absorber layer (the mask). Particulate contamination on the EUVL mask surface, errors in absorber definition and defects in the ML coating all have the potential to print in the lithographic process. While highly developed technologies exist for repair of the absorber layer, no viable strategy for the repair of ML coating defects has been identified. In this paper the state-of-the-art in ML deposition technology, optical inspection of EUVL mask blank defects and candidate absorber patterning approaches are reviewed

  3. Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.

    Science.gov (United States)

    Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo

    2015-04-01

    Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.

  4. Mask leak increases and minute ventilation decreases when chest compressions are added to bag ventilation in a neonatal manikin model.

    Science.gov (United States)

    Tracy, Mark B; Shah, Dharmesh; Hinder, Murray; Klimek, Jan; Marceau, James; Wright, Audrey

    2014-05-01

    To determine changes in respiratory mechanics when chest compressions are added to mask ventilation, as recommended by the International Liaison Committee on Resuscitation (ILCOR) guidelines for newborn infants. Using a Laerdal Advanced Life Support leak-free baby manikin and a 240-mL self-inflating bag, 58 neonatal staff members were randomly paired to provide mask ventilation, followed by mask ventilation with chest compressions with a 1:3 ratio, for two minutes each. A Florian respiratory function monitor was used to measure respiratory mechanics, including mask leak. The addition of chest compressions to mask ventilation led to a significant reduction in inflation rate, from 63.9 to 32.9 breaths per minute (p mask leak of 6.8% (p mask ventilation, in accordance with the ILCOR guidelines, in a manikin model is associated with a significant reduction in delivered ventilation and increase in mask leak. If similar findings occur in human infants needing an escalation in resuscitation, there is a potential risk of either delay in recovery or inadequate response to resuscitation. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. Bilateral diaphragmatic paralysis after cardiac surgery: ventilatory assistance by nasal mask continuous positive airway pressure.

    Science.gov (United States)

    Hoch, B; Zschocke, A; Barth, H; Leonhardt, A

    2001-01-01

    The case of an 8-month-old boy with bilateral diaphragmatic paralysis after surgical reoperation for congenital heart disease is presented. In order to avoid repeated intubation and long-term mechanical ventilation or tracheotomy, we used nasal mask continuous positive airway pressure (CPAP) as an alternative method for assisted ventilation. Within 24 hours the boy accepted the nasal mask and symptoms such as dyspnea and sweating disappeared. Respiratory movements became regular and oxygen saturation increased. Nasal mask CPAP may serve as an alternative treatment of bilateral diaphragmatic paralysis in infants, thereby avoiding tracheotomy or long-term mechanical ventilation.

  6. Mechanical alignment of substrates to a mask

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.; Honan, Michael; Amato, Luigi G.; Grant, Christopher Neil; Strassner, James D.

    2016-11-08

    A plurality of masks is attached to the underside of a mask frame. This attachment is made such that each mask can independently move relative to the mask frame in three directions. This relative movement allows each mask to adjust its position to align with respective alignment pins disposed on a working surface. In one embodiment, each mask is attached to the mask frame using fasteners, where the fasteners have a shaft with a diameter smaller than the diameter of the mounting hole disposed on the mask. A bias element may be used to allow relative movement between the mask and the mask frame in the vertical direction. Each mask may also have kinematic features to mate with the respective alignment pins on the working surface.

  7. Who's Behind that Mask?

    Science.gov (United States)

    Leonard, Stephanie

    2011-01-01

    Part of the fourth-grade curriculum in the author's district is the creation of a self-portrait. This is always a challenge for both the students and the author, because it is so difficult for beginners to draw a satisfying drawing of a face, whether it is their own or someone else's. In the past the author tried many formats and materials to…

  8. Image differencing using masked CCD

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.; Webber, C.J. St. J.

    1987-01-01

    A charge coupled device has some of its ''pixels'' masked by a material which is opaque to the radiation to which the device is to be exposed, each masked region being employed as a storage zone into which the charge pattern from the unmasked pixels can be transferred to enable a subsequent charge pattern to be established on further exposure of the unmasked pixels. The components of the resulting video signal corresponding to the respective charge patterns read-out from the CCD are subtracted to produce a video signal corresponding to the difference between the two images which formed the respective charge patterns. Alternate rows of pixels may be masked, or chequer-board pattern masking may be employed. In an X-ray imaging system the CCD is coupled to image intensifying and converting means. (author)

  9. Vibrotactile masking through the body.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2014-09-01

    Touches on one hand or forearm can affect tactile sensitivity at contralateral locations on the opposite side of the body. These interactions suggest an intimate connection between the two sides of the body. Here, we explore the effect of masking not across the body but through the body by measuring the effect of a masking stimulus on the back on the tactile sensitivity of the corresponding point on the front. Tactile sensitivity was measured on each side of the stomach, while vibrotactile masking stimulation was applied to one side of the front and to points on the back including the point directly behind the test point on the front. Results were compared to sensitivity, while vibrotactile stimulation was applied to a control site on the shoulder. A reduction in sensitivity of about .8 dB was found that required the masking stimulus to be within about 2 cm of the corresponding point on the back.

  10. Hybrid mask for deep etching

    KAUST Repository

    Ghoneim, Mohamed T.

    2017-01-01

    Deep reactive ion etching is essential for creating high aspect ratio micro-structures for microelectromechanical systems, sensors and actuators, and emerging flexible electronics. A novel hybrid dual soft/hard mask bilayer may be deposited during

  11. Rapid iconic erasure without masking.

    Science.gov (United States)

    Tijus, Charles Albert; Reeves, Adam

    2004-01-01

    We report on the erasure of the iconic memory of an array of 12 black letters flashed on a continuously- present white field. Erasure is accomplished by replacing the 16 ms letter array (frame 1) with a blank white frame for 16 ms (frame 2). The letter array returns in frame 3, with from one to six letters missing. Report of the missing letters is accurate without the blank white frame but is impoverished with it, as if interposing the blank erases the icon. Erasure occurs without any obvious luminance masking, 'mud splashes', pattern masking (backward, forward, or metacontrast), lateral masking, or masking by object substitution. Erasure is greatly decreased if the blank is presented one frame earlier or later. We speculate that erasure is due to a rapid reset of the icon produced by an informational mis-match.

  12. Face to Face

    OpenAIRE

    Robert Leckey

    2013-01-01

    This paper uses Queer theory, specifically literature on Bowers v. Hardwick, to analyze debates over legislation proposed in Quebec regarding covered faces. Queer theory sheds light on legal responses to the veil. Parliamentary debates in Quebec reconstitute the polity, notably as secular and united. The paper highlights the contradictory and unstable character of four binaries: legislative text versus social practice, act versus status, majority versus minority, and knowable versus unknowabl...

  13. A new horizon for the use of non-invasive ventilation in patients with acute respiratory distress syndrome.

    Science.gov (United States)

    Carron, Michele

    2016-09-01

    Non-invasive ventilation (NIV) has assumed an important role in the management of acute respiratory failure (ARF). NIV, compared with standard medical therapy, improves survival and reduces complications in selected patients with ARF. NIV represents the first-line intervention for some forms of ARF, such as chronic obstructive pulmonary disease (COPD) exacerbations and acute cardiogenic pulmonary edema. The use of NIV is also well supported for immunocompromised patients who are at high risk for infectious complications from endotracheal intubation. Selection of appropriate patients is crucial for optimizing NIV success rates. Appropriate ventilator settings, a well-fitting and comfortable interface, and a team skilled and experienced in managing NIV are key components to its success. In a recent issue of the Journal of the American Medical Association , Patel et al . reported the results of their single-center trial of 83 patients with acute respiratory distress syndrome (ARDS) who were randomly assigned to NIV delivered via a helmet or face mask. Patients assigned to the helmet group exhibited a significantly lower intubation rate and were more likely to survive through 90 days. This perspective reviews the findings of this trial in the context of current clinical practice and in light of data from the literature focused on the potential reasons for success of NIV delivered through a helmet compared to face mask. The implications for early management of patients with ARDS are likewise discussed.

  14. Respiratory mechanics

    CERN Document Server

    Wilson, Theodore A

    2016-01-01

    This book thoroughly covers each subfield of respiratory mechanics: pulmonary mechanics, the respiratory pump, and flow. It presents the current understanding of the field and serves as a guide to the scientific literature from the golden age of respiratory mechanics, 1960 - 2010. Specific topics covered include the contributions of surface tension and tissue forces to lung recoil, the gravitational deformation of the lung, and the interdependence forces that act on pulmonary airways and blood vessels. The geometry and kinematics of the ribs is also covered in detail, as well as the respiratory action of the external and internal intercostal muscles, the mechanics of the diaphragm, and the quantitative compartmental models of the chest wall is also described. Additionally, flow in the airways is covered thoroughly, including the wave-speed and viscous expiratory flow-limiting mechanisms; convection, diffusion and the stationary front; and the distribution of ventilation. This is an ideal book for respiratory ...

  15. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

    Science.gov (United States)

    Qureshi, Mosarrat J; Kumar, Manoj

    2018-03-15

    Providing effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation. Among newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. We included seven trials that involved a total of 794 infants. Five

  16. Obesity and respiratory diseases

    Directory of Open Access Journals (Sweden)

    Christopher Zammit

    2010-10-01

    Full Text Available Christopher Zammit, Helen Liddicoat, Ian Moonsie, Himender MakkerSleep and Ventilation Unit, Department of Respiratory Medicine, North Middlesex University Hospital, London, UKAbstract: The obesity epidemic is a global problem, which is set to increase over time. However, the effects of obesity on the respiratory system are often underappreciated. In this review, we will discuss the mechanical effects of obesity on lung physiology and the function of adipose tissue as an endocrine organ producing systemic inflammation and effecting central respiratory control. Obesity plays a key role in the development of obstructive sleep apnea and obesity hypoventilation syndrome. Asthma is more common and often harder to treat in the obese population, and in this study, we review the effects of obesity on airway inflammation and respiratory mechanics. We also discuss the compounding effects of obesity on chronic obstructive pulmonary disease (COPD and the paradoxical interaction of body mass index and COPD severity. Many practical challenges exist in caring for obese patients, and we highlight the complications faced by patients undergoing surgical procedures, especially given the increased use of bariatric surgery. Ultimately, a greater understanding of the effects of obesity on the respiratory disease and the provision of adequate health care resources is vital in order to care for this increasingly important patient population.Keywords: obesity, lung function, obstructive sleep apnea, obesity hypoventilation syndrome, anesthesia

  17. Automatic pattern localization across layout database and photolithography mask

    Science.gov (United States)

    Morey, Philippe; Brault, Frederic; Beisser, Eric; Ache, Oliver; Röth, Klaus-Dieter

    2016-03-01

    Advanced process photolithography masks require more and more controls for registration versus design and critical dimension uniformity (CDU). The distribution of the measurement points should be distributed all over the whole mask and may be denser in areas critical to wafer overlay requirements. This means that some, if not many, of theses controls should be made inside the customer die and may use non-dedicated patterns. It is then mandatory to access the original layout database to select patterns for the metrology process. Finding hundreds of relevant patterns in a database containing billions of polygons may be possible, but in addition, it is mandatory to create the complete metrology job fast and reliable. Combining, on one hand, a software expertise in mask databases processing and, on the other hand, advanced skills in control and registration equipment, we have developed a Mask Dataprep Station able to select an appropriate number of measurement targets and their positions in a huge database and automatically create measurement jobs on the corresponding area on the mask for the registration metrology system. In addition, the required design clips are generated from the database in order to perform the rendering procedure on the metrology system. This new methodology has been validated on real production line for the most advanced process. This paper presents the main challenges that we have faced, as well as some results on the global performances.

  18. A masking index for quantifying hidden glitches

    OpenAIRE

    Berti-Equille, Laure; Loh, J. M.; Dasu, T.

    2015-01-01

    Data glitches are errors in a dataset. They are complex entities that often span multiple attributes and records. When they co-occur in data, the presence of one type of glitch can hinder the detection of another type of glitch. This phenomenon is called masking. In this paper, we define two important types of masking and propose a novel, statistically rigorous indicator called masking index for quantifying the hidden glitches. We outline four cases of masking: outliers masked by missing valu...

  19. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    Science.gov (United States)

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  20. Contralateral tactile masking between forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2014-03-01

    Masking effects have been demonstrated in which tactile sensitivity is affected when one touch is close to another on the body surface. Such effects are likely a result of local lateral inhibitory circuits that sharpen the spatial tuning of a given tactile receptor. Mutually inhibitory pathways have also been demonstrated between cortical tactile maps of the two halves of the body. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at contralateral locations. Here, we measure the spatial tuning and effect of posture on this contralateral masking effect. Tactile sensitivity was measured on one forearm, while vibrotactile masking stimulation was applied to the opposite arm. Results were compared to sensitivity while vibrotactile stimulation was applied to a control site on the right shoulder. Sensitivity on the forearm was reduced by over 3 dB when the arms were touching and by 0.52 dB when they were held parallel. The masking effect depended on the position of the masking stimulus. Its effectiveness fell off by 1 STD when the stimulus was 29 % of arm length from the corresponding contralateral point. This long-range inhibitory effect in the tactile system suggests a surprisingly intimate relationship between the two sides of the body.

  1. Self-Rescue Mask Training

    CERN Multimedia

    2013-01-01

    Nine new self-rescue mask instructors have been trained since early 2013, which provides CERN with a total of 26 self-rescue mask instructors to date. This will allow us to meet the increasing training needs caused by the Long Shut Down LS1.   The self-rescue mask instructors have trained 1650 persons in 2012 and about 500 persons since the beginning of the year on how to wear the masks properly. We thank all the instructors and all the persons that made this training possible. Please remember that the self-rescue masks training sessions are scheduled as follows: Basic course: Tuesday and Thursday mornings (2 sessions – 8.30 AM and 10.30 AM), duration:  1.30 hour, in French and English – registration via CERN online training catalogue – Course code 077Y00. Refresher training : Monday mornings (2 sessions – 8.30 AM and 10.30 AM), duration: 1.30 hour , in French and English – registration via CERN online training catalogue &...

  2. 1995 mask industry quality assessment

    Science.gov (United States)

    Bishop, Chris; Strott, Al

    1995-12-01

    The third annual mask industry assessment will again survey various industry companies for key performance measurements in the areas of quality and delivery. This year's assessment is enhanced to include the area of safety and further breakdown of the data into 5-inch vs. 6- inch. The data compiled includes shipments, customer return rate, customer return reason, performance to schedule, plate survival yield, and throughput time (TPT) from 1988 through Q2, 1995. Contributor identities remain protected by utilizing Arthur Andersen & Company to ensure participant confidentiality. Participation in the past included representation of over 75% of the total merchant and captive mask volume in the United States. This year's assessment is expected to result in expanded participation by again inviting all mask suppliers domestically to participate as well as an impact from inviting international suppliers to participate.

  3. Electrostatic mask for active targets

    International Nuclear Information System (INIS)

    Pancin, J; Gangnant, P; Libin, J-F; Raabe, R; Roger, T; Roussel-Chomaz, P; Gibelin, J; Goth, M

    2012-01-01

    Active gas targets have been used in nuclear physics since 30 years. They are promising systems in view of the new exotic beams soon available at facilities like SPIRAL2 or FAIR, but the system can still be improved. One of the main limitation is the dynamic range in energy deposition. The energy deposited per unit length can be 3 decades higher for the beam than for the light reaction products and the risk to saturate the electronics or that the detector spark are not negligible. A simple solution using a wire plane to mask partially the beam is presented here. Some simulation has been realized and some experimental results are shown confirming the feasibility of this wire tunable mask. The mask can be used from full transparency to full opacity without degrading neither the drift electric field of the chamber nor the performances of detection of the beam or the light products.

  4. Self-masking subtraction tomosynthesis

    International Nuclear Information System (INIS)

    Chakraborty, D.P.; Yester, M.V.; Barnes, G.T.; Lakshminarayanan, A.V.

    1984-01-01

    The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation

  5. Mask roughness and its implications for LER at the 22- and 16-nm nodes

    Energy Technology Data Exchange (ETDEWEB)

    Naulleau, Patrick; George, Simi A.; McClinton, Brittany M.

    2010-02-16

    Line-edge roughness (LER) remains the most significant challenge facing the development of extreme ultraviolet (EUV) resist. The mask, however, has been found to be a significant contributor to image-plane LER. This has long been expected based on modeling and has more recently been demonstrated experimentally. Problems arise from both mask-absorber LER as well as mask multilayer roughness leading to random phase variations in the reflected beam and consequently speckle. Understanding the implications this has on mask requirements for the 22-nm half pitch node and below is crucial. Modeling results indicate a replicated surface roughness (RSR) specification of 50 pm and a ruthenium capping layer roughness specification of 440 pm. Moreover, modeling indicates that it is crucial to achieve the current ITRS specifications for mask absorber LER which is significantly smaller than current capabilities.

  6. Face to Face

    Directory of Open Access Journals (Sweden)

    Robert Leckey

    2013-12-01

    Full Text Available This paper uses Queer theory, specifically literature on Bowers v. Hardwick, to analyze debates over legislation proposed in Quebec regarding covered faces. Queer theory sheds light on legal responses to the veil. Parliamentary debates in Quebec reconstitute the polity, notably as secular and united. The paper highlights the contradictory and unstable character of four binaries: legislative text versus social practice, act versus status, majority versus minority, and knowable versus unknowable. As with contradictory propositions about homosexuality, contradiction does not undermine discourse but makes it stronger and more agile. Este artículo utiliza la teoría Queer, más concretamente la literatura sobre Bowers vs. Hardwick, para analizar los debates sobre la legislación propuesta en Quebec en relación al velo. La teoría Queer arroja luz sobre las respuestas legales al velo. Los debates parlamentarios en Quebec reconstituyen la forma de gobierno, especialmente como secular y unido. El documento pone de relieve el carácter contradictorio e inestable de cuatro binarios: texto legislativo frente a las prácticas sociales; legislación frente a estado; mayoría versus minoría; y conocible frente a incognoscible. Al igual que con las proposiciones contradictorias acerca de la homosexualidad, la contradicción no socava el discurso, sino que lo hace más fuerte y más ágil.

  7. Trial manufacture of round mask for TV fluoroscopic unit

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Matsumoto, Yukio

    1977-01-01

    Demands for revision of existing medical law were described together with an introduction of TV fluoroscopic unit. Round mask, which does not always press out the bottom face of used x-ray beam from the effective primary fluorescent face of photomultiplier inspite of shifting of a spot in time of TV fluoroscopy, was manufactured for trial, and it was furnished with already established fluoroscopic stand. It is used in daily examination without any trouble. Round mask was divided into two parts, and opened upward and downward quickly by lod motor in time of photographing. Multiple iris was operated in order to fit to film size, and round mask was closed at the same time of the finishment of photographing and fluoroscopy was performed again. Item 3 of Para 2 of Art 30 of the existing medical low states that it is good not to press out, the distance between x-ray focus and fluorescent screen, and used x-ray beam from fluorescent screen. However, a regulation, which states that x-ray beam should not be pressed out from effective primary fluorescent face in x-ray fluoroscopy using photomultiplier, must be added. Improvement of the existing unit is expected, and decrease of unnecessary exposure even in small amount is proposed. (Tsunoda, M.)

  8. High-emulation mask recognition with high-resolution hyperspectral video capture system

    Science.gov (United States)

    Feng, Jiao; Fang, Xiaojing; Li, Shoufeng; Wang, Yongjin

    2014-11-01

    We present a method for distinguishing human face from high-emulation mask, which is increasingly used by criminals for activities such as stealing card numbers and passwords on ATM. Traditional facial recognition technique is difficult to detect such camouflaged criminals. In this paper, we use the high-resolution hyperspectral video capture system to detect high-emulation mask. A RGB camera is used for traditional facial recognition. A prism and a gray scale camera are used to capture spectral information of the observed face. Experiments show that mask made of silica gel has different spectral reflectance compared with the human skin. As multispectral image offers additional spectral information about physical characteristics, high-emulation mask can be easily recognized.

  9. Recovery benefits of using a heat and moisture exchange mask during sprint exercise in cold temperatures.

    Science.gov (United States)

    Seifert, John G; Frost, Jeremy; St Cyr, John A

    2017-01-01

    Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in the cold. There were three trial arms within this study: wearing the heat and moisture exchange mask during the rest periods in the cold, no-mask application during the rest periods in the cold, and a trial at room temperature (22°C). Eight subjects cycled in four 35 kJ sprint sessions with each session separated by 20 min rest period. Workload was 4% of body mass. Mean sprint times were faster with heat and moisture exchange mask and room temperature trial than cold, no-mask trial (133.8 ± 8.6, 134.9 ± 8.8, and 138.0 ± 8.4 s (p = 0.001)). Systolic blood pressure and mean arterial pressure were greater during the cold trial with no mask (15% and 13%, respectively), and heart rate was 10 bpm less during the third rest or recovery period during cold, no mask compared to the heat and moisture exchange mask and room temperature trials. Subjects demonstrated significant decreases in vital capacity and peak expiratory flow rate during the cold with no mask applied during the rest periods. These negative responses to cold exposure were alleviated by the use of a heat and moisture exchange mask worn during the rest intervals by minimizing cold-induced temperature stress on the respiratory system with subsequent maintenance of cardiovascular function.

  10. Masked hypertension in diabetes mellitus

    DEFF Research Database (Denmark)

    Franklin, Stanley S; Thijs, Lutgarde; Li, Yan

    2013-01-01

    Although distinguishing features of masked hypertension in diabetics are well known, the significance of antihypertensive treatment on clinical practice decisions has not been fully explored. We analyzed 9691 subjects from the population-based 11-country International Database on Ambulatory Blood...

  11. Complete separation of the tube from the mask of a reusable classic laryngeal mask airway: a case report

    Directory of Open Access Journals (Sweden)

    Ali Shahriari

    2007-06-01

    Full Text Available face="TimesNewRoman" size="2">

    The laryngeal mask airway (LMA is an important addition to the anesthetist's equipments. However, its usage may involve some complications. We have encountered an unusual and potentially serious complication using this equipment. A 45-year old man underwent cataract surgery under general anesthesia. After the induction of anesthesia, a size 4 of the reusable classic LMA was inserted without any difficulties and the cuff was inflated. After a little manipulation, the proximal tube of the LMA was separated from the distal part, leaving the distal mask inside the pharynx. The exit of the remaining portion of the LMA was very difficult and made the ventilation of the patient impossible. The patient’s oxygen saturation decreased to 40%. The remaining portion of the LMA was removed by a great clamp and with an extreme effort. Then, an endotracheal tube was inserted and the patient was ventilated with 100% oxygen. After 6 hours, the patient was discharged with no apparent complications. The autoclave was used several times for the sterilization of the LMA.

    face="TimesNewRoman,Bold" size="1">

    KEY WORDS: face="TimesNewRoman" size="2">Laryngeal mask airway, autoclave.

  12. "The Mask Who Wasn't There": Visual Masking Effect with the Perceptual Absence of the Mask

    Science.gov (United States)

    Rey, Amandine Eve; Riou, Benoit; Muller, Dominique; Dabic, Stéphanie; Versace, Rémy

    2015-01-01

    Does a visual mask need to be perceptually present to disrupt processing? In the present research, we proposed to explore the link between perceptual and memory mechanisms by demonstrating that a typical sensory phenomenon (visual masking) can be replicated at a memory level. Experiment 1 highlighted an interference effect of a visual mask on the…

  13. Gestalt grouping and common onset masking.

    Science.gov (United States)

    Kahan, Todd A; Mathis, Katherine M

    2002-11-01

    A four-dot mask that surrounds and is presented simultaneously with a briefly presented target will reduce a person's ability to identity that target if the mask persists beyond target offset and attention is divided (Enns & Di Lollo, 1997, 2000). This masking effect, referred to as common onset masking, reflects reentrant processing in the visual system and can best be explained with a theory of object substitution (Di Lollo, Enns, & Rensink, 2000). In the present experiments, we investigated whether Gestalt grouping variables would influence the strength of common onset masking. The results indicated that (1) masking was impervious to grouping by form, similarity of color, position, luminance polarity, and common region and (2) masking increased with the number of elements in the masking display.

  14. 21 CFR 868.5590 - Scavenging mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scavenging mask. 868.5590 Section 868.5590 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5590 Scavenging mask. (a) Identification. A scavenging mask is a device positioned over a patient's nose to deliver anesthetic or analgesic gases to the...

  15. 21 CFR 868.5580 - Oxygen mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device...

  16. 21 CFR 868.5600 - Venturi mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venturi mask. 868.5600 Section 868.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5600 Venturi mask. (a) Identification. A venturi mask is a...

  17. Rates of initial acceptance of PAP masks and outcomes of mask switching.

    Science.gov (United States)

    Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula

    2016-05-01

    Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

  18. Masking and Partial Masking in Listeners with a High-Frequency Hearing Loss

    NARCIS (Netherlands)

    Smits, J.T.S.; Duifhuis, H.

    1982-01-01

    3 listeners with sensorineural hearing loss ranging from moderate to moderate-severe starting at frequencies higher than 1 kHz participated in two masking experiments and a partial masking experiment. In the first masking experiment, fM = 1 kHz and LM = 50 dB SPL, higher than normal masked

  19. Respiratory care manpower issues.

    Science.gov (United States)

    Mathews, Paul; Drumheller, Lois; Carlow, John J

    2006-03-01

    Although respiratory care is a relatively new profession, its practitioners are deeply involved in providing patient care in the critical care. In preparation for writing this article, we sought to explore the respiratory therapy manpower needs and activities designed to fulfill those needs in critical care practice. We began by delineating the historical development of respiratory care as a profession, the development of its education, and the professional credentialing system. We then conducted several literature reviews with few articles generated. We requested and received data from the American Association for Respiratory Care (AARC), The National Board for Respiratory Care (NBRC), and the Committee on Accreditation of Respiratory Care education (CoARC) relative to their membership, number of credentialed individuals, and educational program student and graduate data for 2000 through 2004. We then conducted two electronic surveys. Survey 1 was a six-item survey that examined the use of mandatory overtime in respiratory care departments. We used a convenience sample of 30 hospitals stratified by size (or=500 beds). Survey 2 was a five-item instrument distributed by blast E-mail to the Society of Critical Care Medicine's Respiratory Care Section members and members of the RC_World list serve. This survey elicited 51 usable and non-duplicative responses from geographically and size-varied institutions. We analyzed these data in several ways from distribution analysis to one-way analysis of variance procedure and appropriate post hoc analysis techniques. Where appropriate, a matched-pairs analysis was performed and these were compared across the variables intensive care unit (ICU) beds per actual number of respiratory care practitioners (RCPs) and ICU beds per preferred number of RCPs. The data gathered from the professional organizations indicated a relatively stable attrition rate (35.2%+/-1.7-3.1%), even in the face of varying enrollments (6,231 in 2004 vs. 4

  20. Case Report of a Pressure Ulcer Occurring Over the Nasal Bridge Due to a Non-Invasive Ventilation Facial Mask.

    Science.gov (United States)

    Rathore, Farooq A; Ahmad, Faria; Zahoor, Muhammad Umar U

    2016-10-03

    Non-invasive ventilation (NIV) is used in patients with respiratory failure, sleep apnoea, and dyspnoea related to pulmonary oedema. NIV is provided through a facial mask. Many complications of NIV facial masks have been reported, including the breakdown of facial skin. We report a case of an elderly male admitted with multiple co-morbidities. The facial mask was applied continuously for NIV, without any relief or formal monitoring of the underlying skin. It resulted in a Grade II pressure ulcer. We discuss the possible mechanism and offer advice for prevention of such device-related pressure ulcers.

  1. Respiratory mechanics during sevoflurane anesthesia in children with and without asthma.

    Science.gov (United States)

    Habre, W; Scalfaro, P; Sims, C; Tiller, K; Sly, P D

    1999-11-01

    We studied lung function in children with and without asthma receiving anesthesia with sevoflurane. Fifty-two children had anesthesia induced with sevoflurane (up to 8%) in a mixture of 50% nitrous oxide in oxygen and then maintained at 3% with children breathing spontaneously via face mask and Jackson-Rees modification of the T-piece. Airway opening pressure and flow were then measured. After insertion of an oral endotracheal tube under 5% sevoflurane, measurements were repeated at 3%, as well as after increasing to 4.2%. Respiratory system resistance (Rrs) and compliance during expiration were calculated using multilinear regression analysis of airway opening pressure and flow, assuming a single-compartment model. Data from 44 children were analyzed (22 asthmatics and 22 normal children). The two groups were comparable with respect to age, weight, ventilation variables, and baseline respiratory mechanics. Intubation was associated with a significant increase in Rrs in asthmatics (17% +/- 49%), whereas in normal children, Rrs slightly decreased (-4% +/- 39%). At 4.2%, Rrs decreased slightly in both groups with almost no change in compliance system resistance. We concluded that in children with mild to moderate asthma, endotracheal intubation during sevoflurane anesthesia was associated with increase in Rrs that was not seen in nonasthmatic children. Tracheal intubation using sevoflurane as sole anesthetic is possible and its frequency is increasing. When comparing children with and without asthma, tracheal intubation under sevoflurane was associated with an increase in respiratory system resistance in asthmatic children. However, no apparent clinical adverse event was observed.

  2. Extracting messages masked by chaos

    International Nuclear Information System (INIS)

    Perez, G.; Cerdeira, H.A.

    1995-01-01

    We show how to extract messages that are masked by a chaotic signal in a system of two Lorenz oscillators. This mask removal is done for two different modes of transmission, a digital one where a parameter of the sender is switched between two values, and an analog mode, where a small amplitude message is added to the carrier signal. We achieve this without using a second Lorenz oscillator as receiver, and without doing a full reconstruction of the dynamics. This method is robust with respect to transformations that impede the unmasking using a Lorenz receiver, and is not affected by the broad-band noise that is inherent to the synchronization process. We also discuss the limitations of this way of extraction for messages in high frequency bands. (author). 12 refs, 4 figs

  3. Rapid mask prototyping for microfluidics.

    Science.gov (United States)

    Maisonneuve, B G C; Honegger, T; Cordeiro, J; Lecarme, O; Thiry, T; Fuard, D; Berton, K; Picard, E; Zelsmann, M; Peyrade, D

    2016-03-01

    With the rise of microfluidics for the past decade, there has come an ever more pressing need for a low-cost and rapid prototyping technology, especially for research and education purposes. In this article, we report a rapid prototyping process of chromed masks for various microfluidic applications. The process takes place out of a clean room, uses a commercially available video-projector, and can be completed in less than half an hour. We quantify the ranges of fields of view and of resolutions accessible through this video-projection system and report the fabrication of critical microfluidic components (junctions, straight channels, and curved channels). To exemplify the process, three common devices are produced using this method: a droplet generation device, a gradient generation device, and a neuro-engineering oriented device. The neuro-engineering oriented device is a compartmentalized microfluidic chip, and therefore, required the production and the precise alignment of two different masks.

  4. Sinusoidal masks for single channel speech separation

    DEFF Research Database (Denmark)

    Mowlaee, Pejman; Christensen, Mads Græsbøll; Jensen, Søren Holdt

    2010-01-01

    In this paper we present a new approach for binary and soft masks used in single-channel speech separation. We present a novel approach called the sinusoidal mask (binary mask and Wiener filter) in a sinusoidal space. Theoretical analysis is presented for the proposed method, and we show...... that the proposed method is able to minimize the target speech distortion while suppressing the crosstalk to a predetermined threshold. It is observed that compared to the STFTbased masks, the proposed sinusoidal masks improve the separation performance in terms of objective measures (SSNR and PESQ) and are mostly...

  5. Respiratory Home Health Care

    Science.gov (United States)

    ... Us Home > Healthy Living > Living With Lung Disease > Respiratory Home Health Care Font: Aerosol Delivery Oxygen Resources ... Teenagers Living With Lung Disease Articles written by Respiratory Experts Respiratory Home Health Care Respiratory care at ...

  6. The Mysterious Noh Mask: Contribution of Multiple Facial Parts to the Recognition of Emotional Expressions

    Science.gov (United States)

    Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki

    2012-01-01

    Background A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. Methodology/Principal Findings In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. Conclusions/Significance The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally

  7. Human or monitor feedback to improve mask ventilation during simulated neonatal cardiopulmonary resuscitation.

    Science.gov (United States)

    Binder, Corinna; Schmölzer, Georg M; O'Reilly, Megan; Schwaberger, Bernhard; Urlesberger, Berndt; Pichler, Gerhard

    2014-03-01

    To investigate if external chest compressions (ECC) increase mask leak, and if human or technical feedback improves mask ventilation during simulated neonatal cardiopulmonary resuscitation (CPR). In this observational study, 32 participants delivered positive pressure ventilation (PPV) to a modified, leak-free manikin via facemask. Mask leak, tidal volume (VT), positive end expiratory pressure (PEEP) and respiratory rate (RR) were measured with a respiratory function monitor (RFM). Participants had to perform four studies. In the first study, participants performed PPV alone as baseline. Thereafter, three studies were performed in random order. In the PPV+ECC+manometer group, participants had to observe the manometer while the RFM was covered; in the PPV+ECC+RFM group, the RFM was used while the manometer was covered; and in the PPV+ECC+verbal feedback group, the RFM and manometer were covered while a team leader viewed the RFM and provided verbal feedback to the participants. Median (IQR) mask leak of all studies was 15% (5-47%). Comparing the studies, PPV+ECC+RFM and PPV+ECC+verbal feedback had significantly less mask leak than PPV+ECC+manometer. Mean (SD) VT of all studies was 9.5±3.5 mL. Comparing all studies, PPV+ECC+RFM had a significantly higher VT than PPV and PPV+ECC+manometer. As well, PPV+ECC+verbal feedback had a significantly higher VT than PPV. PEEP and RR were within our target, mean (SD) PEEP was 6±2 cmH2O and RR was 36±13/min. During simulated neonatal CPR, ECCs did not influence mask leak, and a RFM and verbal feedback were helpful methods to reduce mask leak and increase VT significantly.

  8. Gingival mask: A case report on enhancing smiles

    Directory of Open Access Journals (Sweden)

    Aashritha Shenava

    2014-01-01

    Full Text Available Periodontal attachment loss in the maxillary anterior region can often lead to esthetic and functional clinical problems including disproportional and elongated clinical crowns and visible interdental embrasures. Gingival replacement prosthesis has historically been used to replace lost tissue. A gingival mask is an easily constructed and practical device to optimize the esthetic and functional outcome in these special situations while permitting cleansibility of the prosthesis and supporting tissues. This is a case report of a young female patient treated using silicon gingival veneer with a 2-year follow-up. The silicon gingival mask has enabled the patient to regain her lost smile and face people with newly found confidence also enhancing the esthetic appearance. Virtually, no problem was encountered during the 2 years of usage of the veneer and the patient continues to use it comfortably.

  9. Emotion potentiates response activation and inhibition in masked priming.

    Science.gov (United States)

    Bocanegra, Bruno R; Zeelenberg, René

    2012-01-01

    Previous studies have shown that emotion can have 2-fold effects on perception. At the object-level, emotional stimuli benefit from a stimulus-specific boost in visual attention at the relative expense of competing stimuli. At the visual feature-level, recent findings indicate that emotion may inhibit the processing of small visual details and facilitate the processing of coarse visual features. In the present study, we investigated whether emotion can boost the activation and inhibition of automatic motor responses that are generated prior to overt perception. To investigate this, we tested whether an emotional cue affects covert motor responses in a masked priming task. We used a masked priming paradigm in which participants responded to target arrows that were preceded by invisible congruent or incongruent prime arrows. In the standard paradigm, participants react faster, and commit fewer errors responding to the directionality of target arrows, when they are preceded by congruent vs. incongruent masked prime arrows (positive congruency effect, PCE). However, as prime-target SOAs increase, this effect reverses (negative congruency effect, NCE). These findings have been explained as evidence for an initial activation and a subsequent inhibition of a partial response elicited by the masked prime arrow. Our results show that the presentation of fearful face cues, compared to neutral face cues, increased the size of both the PCE and NCE, despite the fact that the primes were invisible. This is the first demonstration that emotion prepares an individual's visuomotor system for automatic activation and inhibition of motor responses in the absence of visual awareness.

  10. Brightness masking is modulated by disparity structure.

    Science.gov (United States)

    Pelekanos, Vassilis; Ban, Hiroshi; Welchman, Andrew E

    2015-05-01

    The luminance contrast at the borders of a surface strongly influences surface's apparent brightness, as demonstrated by a number of classic visual illusions. Such phenomena are compatible with a propagation mechanism believed to spread contrast information from borders to the interior. This process is disrupted by masking, where the perceived brightness of a target is reduced by the brief presentation of a mask (Paradiso & Nakayama, 1991), but the exact visual stage that this happens remains unclear. In the present study, we examined whether brightness masking occurs at a monocular-, or a binocular-level of the visual hierarchy. We used backward masking, whereby a briefly presented target stimulus is disrupted by a mask coming soon afterwards, to show that brightness masking is affected by binocular stages of the visual processing. We manipulated the 3-D configurations (slant direction) of the target and mask and measured the differential disruption that masking causes on brightness estimation. We found that the masking effect was weaker when stimuli had a different slant. We suggest that brightness masking is partly mediated by mid-level neuronal mechanisms, at a stage where binocular disparity edge structure has been extracted. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. About Face

    Medline Plus

    Full Text Available ... Basics PTSD Treatment What is AboutFace? Resources for Professionals Get Help Home Watch Videos by Topic Videos ... Basics PTSD Treatment What is AboutFace? Resources for Professionals Get Help PTSD We've been there. After ...

  12. About Face

    Medline Plus

    Full Text Available ... Treatment What is AboutFace? Resources for Professionals Get Help Home Watch Videos by Topic Videos by Type ... Treatment What is AboutFace? Resources for Professionals Get Help PTSD We've been there. After a traumatic ...

  13. Prevention of oral bacterial flora transmission by using mouth-to-mask ventilation during CPR.

    Science.gov (United States)

    Cydulka, R K; Connor, P J; Myers, T F; Pavza, G; Parker, M

    1991-01-01

    The Emergency Cardiac Care Committee of the American Heart Association has recently recommended utilizing protective barrier precautions during CPR (1,2). We assessed 17 mask and faceshield resuscitation devices for adequacy of barrier protection. Eight of the devices were faceshields (CPR Microshield, Hygenic, MedCare Mask, Resusci, Samaritan, Sealeasy, Portex); 8 were mask devices (Laerdal, Dyna Med, MTM Emergency Lung Ventilator, MTM Emergency Resuscitator, Res-Q-Flo, Rightway Mouth-to-Mask Resuscitation, Trufit), and one of the devices did not meet the criteria for either faceshield or mask (Lifesaver). All masks were disinfected, applied to the investigator's face as directed by the manufacturers' instructions, and then cultured for oral aerobic bacterial flora on the rescuer side. No mask devices cultured positive for oral aerobic bacterial flora, while 6 of 8 faceshield devices cultured positive for oral aerobic bacterial flora (P less than 0.007). The CPR Microshield and the Portex faceshield were the only devices that did not develop a positive culture. We conclude that all ventilation devices with a one-way valve, except the Sealeasy device, provide adequate barrier type protection from oral aerobic bacterial flora when simulating mouth-to-barrier type protection when performing mouth-to-mouth ventilation.

  14. Auditory and Respiratory Health Disorders Among Workers in an ...

    African Journals Online (AJOL)

    For early detection of respiratory and auditory disorders, spirometry and audiometry should be included in the periodic medical examination. Accurate health records of workers, so, those at risk can be monitored, and/or pre-placed. Using personal protective equipments especially masks and ear muffles as well as prohibit ...

  15. Assessment of respiratory symptoms and lung function among textile ...

    African Journals Online (AJOL)

    The smokers among the exposed and unexposed workers had significantly lower lung function values than nonsmokers. Conclusion: Respiratory symptoms were more prevalent among workers in most dusty sections of the factory. Use of protective mask should be enforced. Workers in the spinning and weaving sections of ...

  16. Effects of a cellulose mask synthesized by a bacterium on facial skin characteristics and user satisfaction

    Directory of Open Access Journals (Sweden)

    Amnuaikit T

    2011-06-01

    Full Text Available Thanaporn Amnuaikit, Toon Chusuit, Panithi Raknam, Prapaporn BoonmeDepartment of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences, Prince of Songkla University, Songkhla, ThailandBackground: Cellulose masks obtained from natural sources such as bacteria are of interest as cosmetic devices for the treatment of dry skin because they not only improve hydration of the skin, but have low toxicity and are biodegradable. The aims of this study were to determine the in vivo effects of a cellulose mask obtained from Acetobacter xylinum on skin characteristics and to evaluate user satisfaction with the product.Methods: Thirty healthy Thai volunteers aged 21–40 years participated in the study. The volunteers were randomly separated into a control group and an experimental group. For the control group, volunteers were assigned to apply moist towels to the face for 25 minutes. For the experimental group, the volunteers were assigned to apply the masks, ie, translucent patches which could be fitted onto the face for the same period. The following week, the groups were changed over to the alternative treatment. Skin moisture, sebum, elasticity, texture, dullness, and desquamation levels were assessed using a system used for routine skin counseling before applying the trial product and five minutes after its removal. Degree of satisfaction with use of the cellulose mask was investigated using a five-point rating scale.Results: The cellulose mask increased moisture levels in the skin significantly more than moist towels (P < 0.05 after a single application. No obvious effects on other skin characteristics were found. The cellulose mask product rated around 4/5 on the satisfaction rating scale.Conclusions: A single application of the trial cellulose mask enhanced moisture uptake by facial skin. Users also reported being satisfied with the trial product.Keywords: bacterial cellulose, facial mask, skin characteristics, skin hydration, user

  17. Reading faces and Facing words

    DEFF Research Database (Denmark)

    Robotham, Julia Emma; Lindegaard, Martin Weis; Delfi, Tzvetelina Shentova

    unilateral lesions, we found no patient with a selective deficit in either reading or face processing. Rather, the patients showing a deficit in processing either words or faces were also impaired with the other category. One patient performed within the normal range on all tasks. In addition, all patients......It has long been argued that perceptual processing of faces and words is largely independent, highly specialised and strongly lateralised. Studies of patients with either pure alexia or prosopagnosia have strongly contributed to this view. The aim of our study was to investigate how visual...... perception of faces and words is affected by unilateral posterior stroke. Two patients with lesions in their dominant hemisphere and two with lesions in their non-dominant hemisphere were tested on sensitive tests of face and word perception during the stable phase of recovery. Despite all patients having...

  18. A Masked Photocathode in a Photoinjector

    OpenAIRE

    Qiang, Ji

    2011-01-01

    In this paper, we propose a masked photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto an electrode, an electrode with small hole is used as a mask to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material easy by rotating the photocathode behind the electrode into the hole. Furthermore, this helps reduce the dark current or seconda...

  19. 3D printed facial laser scans for the production of localised radiotherapy treatment masks - A case study.

    Science.gov (United States)

    Briggs, Matthew; Clements, Helen; Wynne, Neil; Rennie, Allan; Kellett, Darren

    This study investigates the use of 3D printing for patients that require localised radiotherapy treatment to the face. The current process involves producing a lead mask in order to protect the healthy tissue from the effects of the radiotherapy. The mask is produced by applying a thermoplastic sheet to the patient's face and allowing to set hard. This can then be used as a mould to create a plaster impression of the patient's face. A sheet of lead is then hammered on to the plaster to create a bespoke fitted face mask. This process can be distressing for patients and can be problematic when the patient is required to remain motionless for a prolonged time while the thermoplastic sets. In this study, a 1:1 scale 3D print of a patient's face was generated using a laser scanner. The lead was hammered directly on to the surface of the 3D print in order to create a bespoke fitted treatment mask. This eliminated the thermoplastic moulding stage and significantly reduced the time needed for the patient to be in clinic. The higher definition impression of the the face resulted in a more accurate, better fitting treatment mask.

  20. Comparative study of patients suffering sore throat after general anesthesia using laryngeal mask airway and cuffed pharyngeal tube in adults

    Directory of Open Access Journals (Sweden)

    Hassani V

    2001-09-01

    Full Text Available Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent organs, ect. Use of instruments with less invasion to upper respiratory tract, for example, face mask and airway, LMA or CPT are methods, used for decreasing the rate of post-operative sore throat. This study was performed to compare the rate of sore throat after general anesthesia between Laryngeal Mask Airway (LMA and Cuffed Pharyngeal Tube (CPT. From the patients, 120 ASA: PS-I cases, were selected, who were candidates for elective surgery of Orthopedics, Urology, General surgery and Gynecology in Hazrat Rasool-Akram Hospital Complex in the year 2000. Their operation were performed in supine position and did not need muscle relaxation and the patients had spontaneous breathing. Duration of surgery was less than 2 hours. The patients were randomly allocated into two groups: LMA was used for one group and CPT for others. Immediately after operation, in the recovery room and at 6, 12, 18 and 24 hours after removing the tube, the patients were asked about sore throat and the results were recorded in the related sheets. The results was 31.7 percent of patients in group LMA and 0 percent of patients in group CPT, had sore throat. There were significant difference between groups (LMA and CPT in presentation of sore throat (P<0.001.

  1. Predicting masking release of lateralized speech

    DEFF Research Database (Denmark)

    Chabot-Leclerc, Alexandre; MacDonald, Ewen; Dau, Torsten

    2016-01-01

    . The largest masking release (MR) was observed when all maskers were on the opposite side of the target. The data in the conditions containing only energetic masking and modulation masking could be accounted for using a binaural extension of the speech-based envelope power spectrum model [sEPSM; Jørgensen et...... al., 2013, J. Acoust. Soc. Am. 130], which uses a short-term equalization-cancellation process to model binaural unmasking. In the conditions where informational masking (IM) was involved, the predicted SRTs were lower than the measured values because the model is blind to confusions experienced...

  2. About Face

    Medline Plus

    Full Text Available Skip to Content Menu Closed (Tap to Open) Home Interviews Our Stories Search All Videos PTSD Basics PTSD Treatment What is AboutFace? Resources for Professionals Get Help Home Watch Interviews Our ...

  3. About Face

    Medline Plus

    Full Text Available ... not feeling better, you may have PTSD (posttraumatic stress disorder). Watch the intro This is AboutFace In these videos, Veterans, family members, and clinicians share their experiences with PTSD ...

  4. About Face

    Medline Plus

    Full Text Available Skip to Content Menu Closed (Tap to Open) Home Videos by Topic Videos by Type Search All ... What is AboutFace? Resources for Professionals Get Help Home Watch Videos by Topic Videos by Type Search ...

  5. About Face

    Medline Plus

    Full Text Available Skip to Content Menu Closed (Tap to Open) Home Interviews Our Stories Search All Videos PTSD Basics ... What is AboutFace? Resources for Professionals Get Help Home Watch Interviews Our Stories Search All Videos Learn ...

  6. Spontaneous Gender Categorization in Masking and Priming Studies: Key for Distinguishing Jane from John Doe but Not Madonna from Sinatra

    Science.gov (United States)

    Habibi, Ruth; Khurana, Beena

    2012-01-01

    Facial recognition is key to social interaction, however with unfamiliar faces only generic information, in the form of facial stereotypes such as gender and age is available. Therefore is generic information more prominent in unfamiliar versus familiar face processing? In order to address the question we tapped into two relatively disparate stages of face processing. At the early stages of encoding, we employed perceptual masking to reveal that only perception of unfamiliar face targets is affected by the gender of the facial masks. At the semantic end; using a priming paradigm, we found that while to-be-ignored unfamiliar faces prime lexical decisions to gender congruent stereotypic words, familiar faces do not. Our findings indicate that gender is a more salient dimension in unfamiliar relative to familiar face processing, both in early perceptual stages as well as later semantic stages of person construal. PMID:22389697

  7. Security Hi-tech Individual Extra-light Device Mask: a new protection for [soccer] players.

    Science.gov (United States)

    Cascone, Piero; Petrucci, Bernardino; Ramieri, Valerio; Marianetti, Titto Matteo; TitoMatteo, Marianetti

    2008-05-01

    Among professional [soccer] players, a relevant incidence of maxillofacial trauma has been reported. The main challenge in these particular patients is to give them the possibility of a very short convalescence period and to make possible their agonistic activity as soon as possible. The authors here present an innovative technique to realize this--the Security Hi-tech Individual Extra-Light Device Mask, a customizable protective shield based on the player's face cast. A completely customized mask was forged over the player's face cast to protect the injured area. This mask shortens convalescence period, and due to its realization, it is comfortable and easy fitting, thus allowing the player to perform at a professional level in his sport activity in the shortest time possible.

  8. Behind the mask. Journey through an epidemic: some observations of contrasting public health responses to SARS

    Science.gov (United States)

    Syed, Q; Sopwith, W; Regan, M; Bellis, M

    2003-01-01

    SARS has been called the first global epidemic of the 21st century and has been the cause of a massive and varied public health response in many countries of the world. This report describes observations made by two authors on a journey from Manchester in the United Kingdom to Chiang Mai in Thailand during the peak of global transmission. The public response to SARS, particularly characterised by the wearing of face masks, seemed to outstrip official guidance. Though of uncertain protective benefit, the wearing of masks may have contributed to the awareness of the collective and personal responsibility in combating infectious disease. Active and empowered involvement of the general public in implementing and cooperating with public health control measures supported by national and international authorities has clearly helped to bring SARS under control. The public health significance of such potent symbols as the face mask may be considered in strategies to tackle other emerging infections. PMID:14600109

  9. Set Size and Mask Duration Do Not Interact in Object-Substitution Masking

    Science.gov (United States)

    Argyropoulos, Ioannis; Gellatly, Angus; Pilling, Michael; Carter, Wakefield

    2013-01-01

    Object-substitution masking (OSM) occurs when a mask, such as four dots that surround a brief target item, onsets simultaneously with the target and offsets a short time after the target, rather than simultaneously with it. OSM is a reduction in accuracy of reporting the target with the temporally trailing mask, compared with the simultaneously…

  10. Assessment of molecular contamination in mask pod

    Science.gov (United States)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic

  11. Fast mask writers: technology options and considerations

    Science.gov (United States)

    Litt, Lloyd C.; Groves, Timothy; Hughes, Greg

    2011-04-01

    The semiconductor industry is under constant pressure to reduce production costs even as the complexity of technology increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which have added to the complexity of making masks because of the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low-k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that funding on the order of 50M to 90M for non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development poses a high risk for an individual supplier. The structure of the mask fabrication marketplace separates the mask writer equipment customer (the mask supplier) from the final customer (wafer manufacturer) that will be most effected by the increase in mask cost that will result if a high speed mask writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed.

  12. Feature saliency in judging the sex and familiarity of faces.

    Science.gov (United States)

    Roberts, T; Bruce, V

    1988-01-01

    Two experiments are reported on the effect of feature masking on judgements of the sex and familiarity of faces. In experiment 1 the effect of masking the eyes, nose, or mouth of famous and nonfamous, male and female faces on response times in two tasks was investigated. In the first, recognition, task only masking of the eyes had a significant effect on response times. In the second, sex-judgement, task masking of the nose gave rise to a significant and large increase in response times. In experiment 2 it was found that when facial features were presented in isolation in a sex-judgement task, responses to noses were at chance level, unlike those for eyes or mouths. It appears that visual information available from the nose in isolation from the rest of the face is not sufficient for sex judgement, yet masking of the nose may disrupt the extraction of information about the overall topography of the face, information that may be more useful for sex judgement than for identification of a face.

  13. Automatic circuit analysis based on mask information

    International Nuclear Information System (INIS)

    Preas, B.T.; Lindsay, B.W.; Gwyn, C.W.

    1976-01-01

    The Circuit Mask Translator (CMAT) code has been developed which converts integrated circuit mask information into a circuit schematic. Logical operations, pattern recognition, and special functions are used to identify and interconnect diodes, transistors, capacitors, and resistances. The circuit topology provided by the translator is compatible with the input required for a circuit analysis program

  14. Fourier phasing with phase-uncertain mask

    International Nuclear Information System (INIS)

    Fannjiang, Albert; Liao, Wenjing

    2013-01-01

    Fourier phasing is the problem of retrieving Fourier phase information from Fourier intensity data. The standard Fourier phase retrieval (without a mask) is known to have many solutions which cause the standard phasing algorithms to stagnate and produce wrong or inaccurate solutions. In this paper Fourier phase retrieval is carried out with the introduction of a randomly fabricated mask in measurement and reconstruction. Highly probable uniqueness of solution, up to a global phase, was previously proved with exact knowledge of the mask. Here the uniqueness result is extended to the case where only rough information about the mask’s phases is assumed. The exponential probability bound for uniqueness is given in terms of the uncertainty-to-diversity ratio of the unknown mask. New phasing algorithms alternating between the object update and the mask update are systematically tested and demonstrated to have the capability of recovering both the object and the mask (within the object support) simultaneously, consistent with the uniqueness result. Phasing with a phase-uncertain mask is shown to be robust with respect to the correlation in the mask as well as the Gaussian and Poisson noises. (paper)

  15. Ipsilateral masking between acoustic and electric stimulations.

    Science.gov (United States)

    Lin, Payton; Turner, Christopher W; Gantz, Bruce J; Djalilian, Hamid R; Zeng, Fan-Gang

    2011-08-01

    Residual acoustic hearing can be preserved in the same ear following cochlear implantation with minimally traumatic surgical techniques and short-electrode arrays. The combined electric-acoustic stimulation significantly improves cochlear implant performance, particularly speech recognition in noise. The present study measures simultaneous masking by electric pulses on acoustic pure tones, or vice versa, to investigate electric-acoustic interactions and their underlying psychophysical mechanisms. Six subjects, with acoustic hearing preserved at low frequencies in their implanted ear, participated in the study. One subject had a fully inserted 24 mm Nucleus Freedom array and five subjects had Iowa/Nucleus hybrid implants that were only 10 mm in length. Electric masking data of the long-electrode subject showed that stimulation from the most apical electrodes produced threshold elevations over 10 dB for 500, 625, and 750 Hz probe tones, but no elevation for 125 and 250 Hz tones. On the contrary, electric stimulation did not produce any electric masking in the short-electrode subjects. In the acoustic masking experiment, 125-750 Hz pure tones were used to acoustically mask electric stimulation. The acoustic masking results showed that, independent of pure tone frequency, both long- and short-electrode subjects showed threshold elevations at apical and basal electrodes. The present results can be interpreted in terms of underlying physiological mechanisms related to either place-dependent peripheral masking or place-independent central masking.

  16. Computing Challenges in Coded Mask Imaging

    Science.gov (United States)

    Skinner, Gerald

    2009-01-01

    This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

  17. Masked hypertension, a review of the literature.

    NARCIS (Netherlands)

    Verberk, W.J.; Thien, Th.; Leeuw, P.W. de

    2007-01-01

    Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of

  18. New data on masking reagents in complexometry

    International Nuclear Information System (INIS)

    Yurist, I.M.; Talmud, M.M.; Zajtsev, P.M.

    1985-01-01

    Recent literature data on employing inorganic and organic oxygen-, nitrogen- and sulfur-containing substances as masking reagents (MR) in complexonometry of alkali earths, rare earths and transition elements are reviewed for the period of 1971-1983. Effectiveness of any type of MR is shown to be dependent on the electron configuration of a cation being masked. Sr, La, Th, V(6), Zr, Hf, V(5), Nb(5), Ta(5), Mo(6), W(6) a.o. are masked by oxygen-containing ligands. Zn, Cd, Fe(2, 3), Co(2, 3), Ni, etc. are masked by nitrogen- and sulfur-bearing ligands. Thiocompounds mask mainly In, Tl(3), Sn(2), Pb, Bi

  19. Lungs and Respiratory System

    Science.gov (United States)

    ... Videos for Educators Search English Español Lungs and Respiratory System KidsHealth / For Parents / Lungs and Respiratory System ... ll have taken at least 600 million breaths. Respiratory System Basics All of this breathing couldn't ...

  20. Neonatal respiratory distress syndrome

    Science.gov (United States)

    Hyaline membrane disease (HMD); Infant respiratory distress syndrome; Respiratory distress syndrome in infants; RDS - infants ... improves slowly after that. Some infants with severe respiratory distress syndrome will die. This most often occurs ...

  1. About Face

    Medline Plus

    Full Text Available ... at first. But if it's been months or years since the trauma and you're not feeling better, you may have PTSD (posttraumatic stress disorder). Watch the intro This is AboutFace In these videos, Veterans, family members, ...

  2. About Face

    Medline Plus

    Full Text Available ... What is AboutFace? Resources for Professionals Get Help PTSD We've been there. After a traumatic event — ... you're not feeling better, you may have PTSD (posttraumatic stress disorder). Watch the intro This is ...

  3. Pulmonary fibrosis secondary to siderosis causing symptomatic respiratory disease: a case report

    Directory of Open Access Journals (Sweden)

    McCormick Liam M

    2008-08-01

    Full Text Available Abstract Introduction Pulmonary siderosis secondary to the inhalation of iron compounds is a rare condition which, despite striking radiological and histopathological features, has not traditionally been associated with symptoms or functional impairment. Although not the first of its kind, we present an unusual case of pulmonary siderosis with symptomatic respiratory disease, most likely secondary to associated fibrosis. Case presentation A 66-year-old Caucasian man was referred to the outpatient clinic with a 2-year history of exertional breathlessness. He had worked as an engineer for 20 years where he did a significant amount of welding but always wore a face shield. Clinical, radiological and histological features were consistent with a diagnosis of pulmonary siderosis, with associated fibrosis, most likely related to his occupational welding history. Conclusion Our report illustrates that symptomatic respiratory disease due to mild peribronchiolar fibrosis can occur with pulmonary siderosis despite wearing a mask. Furthermore, it reinforces the need for all clinicians to compile a detailed occupational history in individuals presenting with breathlessness.

  4. The Amygdala Is Involved in Affective Priming Effect for Fearful Faces

    Science.gov (United States)

    Yang, J.; Cao, Z.; Xu, X.; Chen, G.

    2012-01-01

    The object of this study was to investigate whether the amygdala is involved in affective priming effect after stimuli are encoded unconsciously and consciously. During the encoding phase, each masked face (fearful or neutral) was presented to participants six times for 17 ms each, using a backward masking paradigm. During the retrieval phase,…

  5. Electrophysiological Correlates of Subliminal Perception of Facial Expressions in Individuals with Autistic Traits: A Backward Masking Study

    OpenAIRE

    Vukusic, Svjetlana; Ciorciari, Joseph; Crewther, David P.

    2017-01-01

    People with Autism spectrum disorder (ASD) show difficulty in social communication, especially in the rapid assessment of emotion in faces. This study examined the processing of emotional faces in typically developing adults with high and low levels of autistic traits (measured using the Autism Spectrum Quotient—AQ). Event-related potentials (ERPs) were recorded during viewing of backward-masked neutral, fearful and happy faces presented under two conditions: subliminal (16 ms, below the leve...

  6. An interactive tool for gamut masking

    Science.gov (United States)

    Song, Ying; Lau, Cheryl; Süsstrunk, Sabine

    2014-02-01

    Artists often want to change the colors of an image to achieve a particular aesthetic goal. For example, they might limit colors to a warm or cool color scheme to create an image with a certain mood or feeling. Gamut masking is a technique that artists use to limit the set of colors they can paint with. They draw a mask over a color wheel and only use the hues within the mask. However, creating the color palette from the mask and applying the colors to the image requires skill. We propose an interactive tool for gamut masking that allows amateur artists to create an image with a desired mood or feeling. Our system extracts a 3D color gamut from the 2D user-drawn mask and maps the image to this gamut. The user can draw a different gamut mask or locally refine the image colors. Our voxel grid gamut representation allows us to represent gamuts of any shape, and our cluster-based image representation allows the user to change colors locally.

  7. Reflective masks for extreme ultraviolet lithography

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Khanh Bao [Univ. of California, Berkeley, CA (United States)

    1994-05-01

    Extreme ultraviolet lithographic masks are made by patterning multilayer reflective coatings with high normal incidence reflectivity. Masks can be patterned by depositing a patterned absorber layer above the coating or by etching the pattern directly into the coating itself. Electromagnetic simulations showed that absorber-overlayer masks have superior imaging characteristics over etched masks (less sensitive to incident angles and pattern profiles). In an EUVL absorber overlayer mask, defects can occur in the mask substrate, reflective coating, and absorber pattern. Electromagnetic simulations showed that substrate defects cause the most severe image degradation. A printability study of substrate defects for absorber overlayer masks showed that printability of 25 nm high substrate defects are comparable to defects in optical lithography. Simulations also indicated that the manner in which the defects are covered by multilayer reflective coatings can affect printability. Coverage profiles that result in large lateral spreading of defect geometries amplify the printability of the defects by increasing their effective sizes. Coverage profiles of Mo/Si coatings deposited above defects were studied by atomic force microscopy and TEM. Results showed that lateral spread of defect geometry is proportional to height. Undercut at defect also increases the lateral spread. Reductions in defect heights were observed for 0.15 μm wide defect lines. A long-term study of Mo/Si coating reflectivity revealed that Mo/Si coatings with Mo as the top layer suffer significant reductions in reflectivity over time due to oxidation.

  8. Effect of Ibuprofen on masking endodontic diagnosis.

    Science.gov (United States)

    Read, Jason K; McClanahan, Scott B; Khan, Asma A; Lunos, Scott; Bowles, Walter R

    2014-08-01

    An accurate diagnosis is of upmost importance before initiating endodontic treatment; yet, there are occasions when the practitioner cannot reproduce the patient's chief complaint because the patient has become asymptomatic. Ibuprofen taken beforehand may "mask" or eliminate the patient's symptoms. In fact, 64%-83% of patients with dental pain take analgesics before seeing a dentist. The purpose of this study was to examine the possible "masking" effect of ibuprofen on endodontic diagnostic tests. Forty-two patients with endodontic pain underwent testing (cold, percussion, palpation, and bite force measurement) and then received either placebo or 800 mg ibuprofen. Both patients and operators were blinded to the medication received. One hour later, diagnostic testing was repeated and compared with pretreatment testing. Ibuprofen affected testing values for vital teeth by masking palpation 40%, percussion 25%, and cold 25% on affected teeth with symptomatic irreversible pulpitis and symptomatic apical periodontitis. There was no observed masking effect in the placebo group on palpation, percussion, or cold values. When nonvital teeth were included, the masking effect of ibuprofen was decreased. However, little masking occurred with the bite force measurement differences. Analgesics taken before the dental appointment can affect endodontic diagnostic testing results. Bite force measurements can assist in identifying the offending tooth in cases in which analgesics "mask" the endodontic diagnosis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Polymer Masks for nanostructuring of graphene

    DEFF Research Database (Denmark)

    Shvets, Violetta

    This PhD project is a part of Center for Nanostructured Graphene (CNG) activities. The aim of the project is to develop a new lithography method for creation of highly ordered nanostructures with as small as possible feature and period sizes. The method should be applicable for graphene nanostruc...... demonstrated the opening of what could be interpreted as a band gap....... polymer masks is developed. Mask fabrication is realized by microtoming of 30-60 nm thin sections from pre-aligned polymer monoliths with different morphologies. The resulting polymer masks are then transferred to both silicon and graphene substrates. Hexagonally packed hole patterns with 10 nm hole...

  10. When Bad Masks Turn Good

    Science.gov (United States)

    Abraham, Roberto G.

    In keeping with the spirit of a meeting on ‘masks,' this talk presents two short stories on the theme of dust. In the first, dust plays the familiar role of the evil obscurer, the enemy to bedefeated by the cunning observer in order to allow a key future technology (adaptive optics) to be exploited fully by heroic astronomers. In the second story, dust itself emerges as the improbable hero, in the form of a circumstellar debris disks. I will present evidence of a puzzling near-infrared excess in the continuum of high-redshift galaxies and will argue that the seemingly improbable origin of this IR excess is a population of young circumstellar disks formed around high-mass stars in distant galaxies. Assuming circumstellar disks extend down to lower masses,as they do in our own Galaxy, the excess emission presents us with an exciting opportunity to measure the formation rate of planetary systems in distant galaxies at cosmic epochs before our own solar system formed.

  11. Middle East Respiratory Syndrome

    Centers for Disease Control (CDC) Podcasts

    2014-07-07

    This podcast discusses Middle East Respiratory Syndrome, or MERS, a viral respiratory illness caused by Middle East Respiratory Syndrome Coronavirus—MERS-CoV.  Created: 7/7/2014 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 7/7/2014.

  12. Sex Differences in Face Processing: Are Women Less Lateralized and Faster than Men?

    Science.gov (United States)

    Godard, Ornella; Fiori, Nicole

    2010-01-01

    The aim of this study was to determine the influence of sex on hemispheric asymmetry and cooperation in a face recognition task. We used a masked priming paradigm in which the prime stimulus was centrally presented; it could be a bisymmetric face or a hemi-face in which facial information was presented in the left or the right visual field and…

  13. Effect of Wearing the Elevation Training Mask on Aerobic Capacity, Lung Function, and Hematological Variables

    Directory of Open Access Journals (Sweden)

    John P. Porcari, Lauren Probst, Karlei Forrester, Scott Doberstein, Carl Foster, Maria L. Cress, Katharina Schmidt

    2016-06-01

    Full Text Available Altitude training and respiratory muscle training (RMT have been reported to improve performance in elite and well-trained athletes. Several devices (altitude and RMT have been developed to help athletes gain the competitive edge. The Elevation Training Mask 2.0 (ETM purportedly simulates altitude training and has been suggested to increase aerobic capacity (VO2max, endurance performance, and lung function. Twenty-four moderately trained subjects completed 6 weeks of high-intensity cycle ergometer training. Subjects were randomized into a mask (n = 12 or control (n = 12 group. Pre and post-training tests included VO2max, pulmonary function, maximal inspiration pressure, hemoglobin and hematocrit. No significant differences were found in pulmonary function or hematological variables between or within groups. There was a significant improvement in VO2max and PPO in both the control (13.5% and 9.9% and mask (16.5% and 13.6% groups. There was no difference in the magnitude of improvement between groups. Only the mask group had significant improvements in ventilatory threshold (VT (13.9%, power output (PO at VT (19.3%, respiratory compensation threshold (RCT (10.2%, and PO at RCT (16.4% from pre to post-testing. The trends for improvements in VT and PO at VT between groups were similar to improvements in RCT and PO at RCT, but did not reach statistical significance (VT p = 0.06, PO at VT p = 0.170. Wearing the ETM while participating in a 6-week high-intensity cycle ergometer training program does not appear to act as a simulator of altitude, but more like a respiratory muscle training device. Wearing the ETM may improve specific markers of endurance performance beyond the improvements seen with interval training alone.

  14. Evaluation of Criteria to Detect Masked Hypertension

    Science.gov (United States)

    Booth, John N.; Muntner, Paul; Diaz, Keith M.; Viera, Anthony J.; Bello, Natalie A.; Schwartz, Joseph E.; Shimbo, Daichi

    2016-01-01

    The prevalence of masked hypertension, out-of-clinic daytime systolic/diastolic blood pressure (SBP/DBP)≥135/85 mmHg on ambulatory blood pressure monitoring (ABPM) among adults with clinic SBP/DBPABPM testing criterion. In a derivation cohort (n=695), the index was clinic SBP+1.3*clinic DBP. In an external validation cohort (n=675), the sensitivity for masked hypertension using an index ≥190 mmHg and ≥217 mmHg and prehypertension status was 98.5%, 71.5% and 82.5%, respectively. Using NHANES data (n=11,778), we estimated that these thresholds would refer 118.6, 44.4 and 59.3 million US adults, respectively, to ABPM screening for masked hypertension. In conclusion, the CBP index provides a useful approach to identify candidates for masked hypertension screening using ABPM. PMID:27126770

  15. Active mask segmentation of fluorescence microscope images.

    Science.gov (United States)

    Srinivasa, Gowri; Fickus, Matthew C; Guo, Yusong; Linstedt, Adam D; Kovacević, Jelena

    2009-08-01

    We propose a new active mask algorithm for the segmentation of fluorescence microscope images of punctate patterns. It combines the (a) flexibility offered by active-contour methods, (b) speed offered by multiresolution methods, (c) smoothing offered by multiscale methods, and (d) statistical modeling offered by region-growing methods into a fast and accurate segmentation tool. The framework moves from the idea of the "contour" to that of "inside and outside," or masks, allowing for easy multidimensional segmentation. It adapts to the topology of the image through the use of multiple masks. The algorithm is almost invariant under initialization, allowing for random initialization, and uses a few easily tunable parameters. Experiments show that the active mask algorithm matches the ground truth well and outperforms the algorithm widely used in fluorescence microscopy, seeded watershed, both qualitatively, as well as quantitatively.

  16. Masking of aluminum surface against anodizing

    Science.gov (United States)

    Crawford, G. B.; Thompson, R. E.

    1969-01-01

    Masking material and a thickening agent preserve limited unanodized areas when aluminum surfaces are anodized with chromic acid. For protection of large areas it combines well with a certain self-adhesive plastic tape.

  17. Mask-induced aberration in EUV lithography

    Science.gov (United States)

    Nakajima, Yumi; Sato, Takashi; Inanami, Ryoichi; Nakasugi, Tetsuro; Higashiki, Tatsuhiko

    2009-04-01

    We estimated aberrations using Zernike sensitivity analysis. We found the difference of the tolerated aberration with line direction for illumination. The tolerated aberration of perpendicular line for illumination is much smaller than that of parallel line. We consider this difference to be attributable to the mask 3D effect. We call it mask-induced aberration. In the case of the perpendicular line for illumination, there was a difference in CD between right line and left line without aberration. In this report, we discuss the possibility of pattern formation in NA 0.25 generation EUV lithography tool. In perpendicular pattern for EUV light, the dominant part of aberration is mask-induced aberration. In EUV lithography, pattern correction based on the mask topography effect will be more important.

  18. Nablus mask-like facial syndrome

    DEFF Research Database (Denmark)

    Allanson, Judith; Smith, Amanda; Hare, Heather

    2012-01-01

    Nablus mask-like facial syndrome (NMLFS) has many distinctive phenotypic features, particularly tight glistening skin with reduced facial expression, blepharophimosis, telecanthus, bulky nasal tip, abnormal external ear architecture, upswept frontal hairline, and sparse eyebrows. Over the last few...

  19. The fastest saccadic responses escape visual masking

    DEFF Research Database (Denmark)

    Crouzet, Sébastien M.; Overgaard, Morten; Busch, Niko A.

    2014-01-01

    Object-substitution masking (OSM) occurs when a briefly presented target in a search array is surrounded by small dots that remain visible after the target disappears. The reduction of target visibility occurring after OSM has been suggested to result from a specific interference with reentrant......, which gives access to very early stages of visual processing, target visibility was reduced either by OSM, conventional backward masking, or low stimulus contrast. A general reduction of performance was observed in all three conditions. However, the fastest saccades did not show any sign of interference...... under either OSM or backward masking, as they did under the low-contrast condition. This finding supports the hypothesis that masking interferes mostly with reentrant processing at later stages, while leaving early feedforward processing largely intact....

  20. Attentional capture by masked colour singletons.

    Science.gov (United States)

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  1. Design of Data Masking Architecture and Analysis of Data Masking Techniques for Testing

    OpenAIRE

    Ravikumar G K,; Manjunath T. N,; Ravindra S. Hegadi,; Archana.R.A

    2011-01-01

    Data masking is the process of obscuring-masking, specific data elements within data stores. It ensures that sensitive data is replaced with realistic but not real data. The goal is that sensitive customer information is not available outside of the authorized environment. Data masking is typically done while provisioning nonproduction environments so that copies created to support test and development processes are not exposing sensitive information and thus avoiding risks of leaking. Maskin...

  2. Effects of hard mask etch on final topography of advanced phase shift masks

    Science.gov (United States)

    Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin

    2017-07-01

    Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.

  3. Respiratory difficulties and breathing disorders in achondroplasia.

    Science.gov (United States)

    Afsharpaiman, S; Saburi, A; Waters, Karen A

    2013-12-01

    Respiratory difficulties and breathing disorders in achondroplasia are thought to underlie the increased risk for sudden infant death and neuropsychological deficits seen in this condition. This review evaluates literature regarding respiratory dysfunctions and their sequelae in patients with achondroplasia. The limited number of prospective studies of respiratory disease in achondroplasia means that observational studies and case series provide a large proportion of the data regarding the spectrum of respiratory diseases in achondroplasia and their treatments. Amongst clinical respiratory problems described, snoring is the commonest observed abnormality, but the reported incidence of obstructive sleep apnoea (OSA) shows wide variance (10% to 75%). Reported treatments of OSA include adenotonsillectomy, the use of CPAP, and surgical improvement of the airway, including mid-face advancement. Otolaryngologic manifestations are also common. Respiratory failure due to small thoracic volumes is reported, but uncommon. Mortality rate at all ages was 2.27 (CI: 1.7-3.0) with age-specific mortality increased at all ages. Sudden death was most common in infants and children. Cardiovascular events are the main cause of mortality in adults. Despite earlier recognition and treatment of respiratory complications of achondroplasia, increased mortality rates and other complications remain high. Future and ongoing evaluation of the prevalence and impact of respiratory disorders, particularly OSA, in achondroplasia is recommended. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Active Mask Segmentation of Fluorescence Microscope Images

    OpenAIRE

    Srinivasa, Gowri; Fickus, Matthew C.; Guo, Yusong; Linstedt, Adam D.; Kovačević, Jelena

    2009-01-01

    We propose a new active mask algorithm for the segmentation of fluorescence microscope images of punctate patterns. It combines the (a) flexibility offered by active-contour methods, (b) speed offered by multiresolution methods, (c) smoothing offered by multiscale methods, and (d) statistical modeling offered by region-growing methods into a fast and accurate segmentation tool. The framework moves from the idea of the “contour” to that of “inside and outside”, or, masks, allowing for easy mul...

  5. Refinement of the CALIOP cloud mask algorithm

    Science.gov (United States)

    Katagiri, Shuichiro; Sato, Kaori; Ohta, Kohei; Okamoto, Hajime

    2018-04-01

    A modified cloud mask algorithm was applied to the CALIOP data to have more ability to detect the clouds in the lower atmosphere. In this algorithm, we also adopt the fully attenuation discrimination and the remain noise estimation using the data obtained at an altitude of 40 km to avoid contamination of stratospheric aerosols. The new cloud mask shows an increase in the lower cloud fraction. Comparison of the results to the data observed with a PML ground observation was also made.

  6. Masked Uncontrolled Hypertension in CKD.

    Science.gov (United States)

    Agarwal, Rajiv; Pappas, Maria K; Sinha, Arjun D

    2016-03-01

    Masked uncontrolled hypertension (MUCH) is diagnosed in patients treated for hypertension who are normotensive in the clinic but hypertensive outside. In this study of 333 veterans with CKD, we prospectively evaluated the prevalence of MUCH as determined by ambulatory BP monitoring using three definitions of hypertension (daytime hypertension ≥135/85 mmHg; either nighttime hypertension ≥120/70 mmHg or daytime hypertension; and 24-hour hypertension ≥130/80 mmHg) or by home BP monitoring (hypertension ≥135/85 mmHg). The prevalence of MUCH was 26.7% by daytime ambulatory BP, 32.8% by 24-hour ambulatory BP, 56.1% by daytime or night-time ambulatory BP, and 50.8% by home BP. To assess the reproducibility of the diagnosis, we repeated these measurements after 4 weeks. Agreement in MUCH diagnosis by ambulatory BP was 75-78% (κ coefficient for agreement, 0.44-0.51), depending on the definition used. In contrast, home BP showed an agreement of only 63% and a κ coefficient of 0.25. Prevalence of MUCH increased with increasing clinic systolic BP: 2% in the 90-110 mmHg group, 17% in the 110-119 mmHg group, 34% in the 120-129 mmHg group, and 66% in the 130-139 mmHg group. Clinic BP was a good determinant of MUCH (receiver operating characteristic area under the curve 0.82; 95% confidence interval 0.76-0.87). In diagnosing MUCH, home BP was not different from clinic BP. In conclusion, among people with CKD, MUCH is common and reproducible, and should be suspected when clinic BP is in the prehypertensive range. Confirmation of MUCH diagnosis should rely on ambulatory BP monitoring. Copyright © 2016 by the American Society of Nephrology.

  7. Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects

    Science.gov (United States)

    Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana

    2015-01-01

    Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495

  8. Modulation cues influence binaural masking-level difference in masking-pattern experiments.

    Science.gov (United States)

    Nitschmann, Marc; Verhey, Jesko L

    2012-03-01

    Binaural masking patterns show a steep decrease in the binaural masking-level difference (BMLD) when masker and signal have no frequency component in common. Experimental threshold data are presented together with model simulations for a diotic masker centered at 250 or 500 Hz and a bandwidth of 10 or 100 Hz masking a sinusoid interaurally in phase (S(0)) or in antiphase (S(π)). Simulations with a binaural model, including a modulation filterbank for the monaural analysis, indicate that a large portion of the decrease in the BMLD in remote-masking conditions may be due to an additional modulation cue available for monaural detection. © 2012 Acoustical Society of America

  9. Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.

    Science.gov (United States)

    Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana

    2016-01-01

    The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.

  10. Phase mask coronagraphy at JPL and Palomar

    Directory of Open Access Journals (Sweden)

    Serabyn E.

    2011-07-01

    Full Text Available For the imaging of faint companions, phase mask coronagraphy has the dual advantages of a small inner working angle and high throughput. This paper summarizes our recent work in developing phase masks and in demonstrating their capabilities at JPL. Four-quadrant phase masks have been manufactured at JPL by means of both evaporation and etching, and we have been developing liquid crystal vortex phase masks in partnership with a commercial vendor. Both types of mask have been used with our extreme adaptive optics well-corrected subaperture at Palomar to detect known brown dwarf companions as close as ~ 2.5 λ/D to stars. Moreover, our recent vortex masks perform very well in laboratory tests, with a demonstrated infrared contrast of about 10−6 at 3 λ/D, and contrasts of a few 10−7 with an initial optical wavelength device. The demonstrated performance already meets the needs of ground-based extreme adaptive optics coronagraphy, and further planned improvements are aimed at reaching the 10−10 contrast needed for terrestrial exoplanet detection with a space-based coronagraph.

  11. Evaluation of human body irradiation caused by radionuclides deposited in the filtration unit of gas mask

    International Nuclear Information System (INIS)

    Cerny, R.; Otahal, P.; Johnova, K.; Thinova, L.; Kluson, J.

    2017-01-01

    Radioactive aerosol particles represent a serious risk for people facing the consequences of nuclear accident of any kind. The first responders to emergency situation need to be protected by personal protective equipment which includes radiation protection suit supplemented with gas mask. The purpose of this work is to estimate the dose to the organs of responder s body as a result of radionuclide deposition in the filtration unit of the gas mask. The problem was analyzed using Monte Carlo simulations. The dose absorbed by different organs for five representative radionuclides and the dose distribution over the responder s body are presented in this paper. Based on presented MC simulations, we suggest a method of evaluating the irradiation of the responder by the radionuclides deposited in the filtration unit of the gas mask. (authors)

  12. Guide to industrial respiratory protection

    International Nuclear Information System (INIS)

    Pritchard, J.A.

    1977-03-01

    The Occupational Safety and Health Act of 1970 has increased the emphasis on proper selection and use of respirators in situations where engineering controls are not feasible or are being implemented. Although a great deal of information on respiratory protection has been published, most of it is more technical than necessary for the average user faced with day-to-day problems of respiratory protection in industrial environments. This Guide is to provide the industrial user a single reference source containing enough information for establishing and maintaining a respirator program that meets the OSHA requirements outlined in 29 CFR Part 1910.134. It includes chapters on respirator selection, use, maintenance, and inspection, a complete description of all types of respirators and their advantages and limitations, and chapters on respirator fitting and wearer training, respiratory physiology, respiratory hazards, and physiological and psychological limitations. Also included are samples of the decision logic used in respirator selection, guidance on setting up an adequate respirator program through formulation of written standard operating procedures, and discussion of the meaning of the approved respirator

  13. Conceptual Masking: How One Picture Captures Attention from Another Picture.

    Science.gov (United States)

    Loftus, Geoffrey R.; And Others

    1988-01-01

    Five experiments studied operations of conceptual masking--the reduction of conceptual memory performance for an initial stimulus when it is followed by a masking picture process. The subjects were 337 undergraduates at the University of Washington (Seattle). Conceptual masking is distinguished from perceptual masking. (TJH)

  14. Analysis and test of laws for backward (metacontrast) masking

    NARCIS (Netherlands)

    Francis, G.; Rothmayer, M.; Hermens, F.

    2004-01-01

    In backward visual masking, it is common to find that the mask has its biggest effect when it follows the target by several tens of milliseconds. Research in the 1960s and 1970s suggested that masking effects were best characterized by the stimulus onset asynchrony (SOA) between the target and mask.

  15. Orientation tuning of contrast masking caused by motion streaks.

    Science.gov (United States)

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  16. 37 CFR 211.3 - Mask work fees.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  17. 21 CFR 868.5560 - Gas mask head strap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  18. Noninvasive ventilation in hypoxemic respiratory failure

    Directory of Open Access Journals (Sweden)

    Raja Dhar

    2016-01-01

    Full Text Available Noninvasive ventilation (NIV refers to positive pressure ventilation delivered through a noninvasive interface (nasal mask, facemask, or nasal plugs etc. Over the past decade its use has become more common as its benefits are increasingly recognized. This review will focus on the evidence supporting the use of NIV in various conditions resulting in acute hypoxemic respiratory failure (AHRF, that is, non-hypercapnic patients having acute respiratory failure in the absence of a cardiac origin or underlying chronic pulmonary disease. Outcomes depend on the patient's diagnosis and clinical characteristics. Patients should be monitored closely for signs of noninvasive ventilation failure and promptly intubated before a crisis develops. The application of noninvasive ventilation by a trained and experienced team, with careful patient selection, should optimize patient outcomes.

  19. Perception of Scary Halloween Masks by Zoo Animals and Humans

    OpenAIRE

    Sinnott, Joan M.; Speaker, H. Anton; Powell, Laura A.; Mosteller, Kelly W.

    2012-01-01

    Zoo animals were tested to see if they perceived the scary nature of Halloween masks, using a procedure that measured the avoidance response latency to take food from a masked human experimenter. Human perception of the masks was also assessed using a rating scale, with results showing that a Bill Clinton mask was rated not scary, while a Vampire mask was rated very scary. Animal results showed that primate latencies correlated significantly with the human ratings, while non-primate latencies...

  20. Psychophysical thresholds of face visibility during infancy

    DEFF Research Database (Denmark)

    Gelskov, Sofie; Kouider, Sid

    2010-01-01

    The ability to detect and focus on faces is a fundamental prerequisite for developing social skills. But how well can infants detect faces? Here, we address this question by studying the minimum duration at which faces must appear to trigger a behavioral response in infants. We used a preferential...... looking method in conjunction with masking and brief presentations (300 ms and below) to establish the temporal thresholds of visibility at different stages of development. We found that 5 and 10 month-old infants have remarkably similar visibility thresholds about three times higher than those of adults....... By contrast, 15 month-olds not only revealed adult-like thresholds, but also improved their performance through memory-based strategies. Our results imply that the development of face visibility follows a non-linear course and is determined by a radical improvement occurring between 10 and 15 months....

  1. Simultaneous pure-tone masking : the dependence of masking asymmetries on intensity

    NARCIS (Netherlands)

    Vogten, L.L.M.

    1978-01-01

    Phase locking between probe and masker was used in a series of pure-tone masking experiments. The masker was a stationary sine wave of variable frequency; the probe a fixed-frequency tone burst. We have observed that for small frequency separation the masking behaves asymmetrically around the probe

  2. An etching mask and a method to produce an etching mask

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to an etching mask comprising silicon containing block copolymers produced by self-assembly techniques onto silicon or graphene substrate. Through the use of the etching mask, nanostructures having long linear features having sub-10 nm width can be produced....

  3. A Meta-Analysis of the Association between Gender and Protective Behaviors in Response to Respiratory Epidemics and Pandemics.

    Science.gov (United States)

    Moran, Kelly R; Del Valle, Sara Y

    2016-01-01

    Respiratory infectious disease epidemics and pandemics are recurring events that levy a high cost on individuals and society. The health-protective behavioral response of the public plays an important role in limiting respiratory infectious disease spread. Health-protective behaviors take several forms. Behaviors can be categorized as pharmaceutical (e.g., vaccination uptake, antiviral use) or non-pharmaceutical (e.g., hand washing, face mask use, avoidance of public transport). Due to the limitations of pharmaceutical interventions during respiratory epidemics and pandemics, public health campaigns aimed at limiting disease spread often emphasize both non-pharmaceutical and pharmaceutical behavioral interventions. Understanding the determinants of the public's behavioral response is crucial for devising public health campaigns, providing information to parametrize mathematical models, and ultimately limiting disease spread. While other reviews have qualitatively analyzed the body of work on demographic determinants of health-protective behavior, this meta-analysis quantitatively combines the results from 85 publications to determine the global relationship between gender and health-protective behavioral response. The results show that women in the general population are about 50% more likely than men to adopt/practice non-pharmaceutical behaviors. Conversely, men in the general population are marginally (about 12%) more likely than women to adopt/practice pharmaceutical behaviors. It is possible that factors other than pharmaceutical/non-pharmaceutical status not included in this analysis act as moderators of this relationship. These results suggest an inherent difference in how men and women respond to epidemic and pandemic respiratory infectious diseases. This information can be used to target specific groups when developing non-pharmaceutical public health campaigns and to parameterize epidemic models incorporating demographic information.

  4. A Meta-Analysis of the Association between Gender and Protective Behaviors in Response to Respiratory Epidemics and Pandemics.

    Directory of Open Access Journals (Sweden)

    Kelly R Moran

    Full Text Available Respiratory infectious disease epidemics and pandemics are recurring events that levy a high cost on individuals and society. The health-protective behavioral response of the public plays an important role in limiting respiratory infectious disease spread. Health-protective behaviors take several forms. Behaviors can be categorized as pharmaceutical (e.g., vaccination uptake, antiviral use or non-pharmaceutical (e.g., hand washing, face mask use, avoidance of public transport. Due to the limitations of pharmaceutical interventions during respiratory epidemics and pandemics, public health campaigns aimed at limiting disease spread often emphasize both non-pharmaceutical and pharmaceutical behavioral interventions. Understanding the determinants of the public's behavioral response is crucial for devising public health campaigns, providing information to parametrize mathematical models, and ultimately limiting disease spread. While other reviews have qualitatively analyzed the body of work on demographic determinants of health-protective behavior, this meta-analysis quantitatively combines the results from 85 publications to determine the global relationship between gender and health-protective behavioral response. The results show that women in the general population are about 50% more likely than men to adopt/practice non-pharmaceutical behaviors. Conversely, men in the general population are marginally (about 12% more likely than women to adopt/practice pharmaceutical behaviors. It is possible that factors other than pharmaceutical/non-pharmaceutical status not included in this analysis act as moderators of this relationship. These results suggest an inherent difference in how men and women respond to epidemic and pandemic respiratory infectious diseases. This information can be used to target specific groups when developing non-pharmaceutical public health campaigns and to parameterize epidemic models incorporating demographic information.

  5. Comparison and Evaluation of the Effects of Administration of Postoperative Non-Invasive Mechanical Ventilation Methods (CPAP and BIPAP) on Respiratory Mechanics and Gas Exchange in Patients Undergoing Abdominal Surgery.

    Science.gov (United States)

    Yağlıoğlu, Hatice; Köksal, Güniz Meyancı; Erbabacan, Emre; Ekici, Birsel

    2015-08-01

    The aim of our study is to investigate the effect of two different methods of continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BIPAP) and oxygen support under spontaneous ventilation on respiration mechanics, gas exchange, dry mouth and face mask lesion during an early postoperative period in patients undergoing upper abdominal surgery. Eighty patients undergoing elective abdominal surgery with laparotomy, between the age of 25 and 75 years and American Society of Anesthesiologists Physical Status score (ASA) II-III with chronic obstructive pulmonary disease (COPD) diagnosis were included to the study. Subjects were randomly allocated in to four groups. During the first postoperative hour, the first group received BIPAP, second group received high-flow CPAP, third group received low-flow CPAP and fourth group received deep breathing exercises, respiratory physiotherapy and O2 therapy. Preoperative, postoperative before and after treatment PaO2, PaCO2, SpO2, tidal volume (TV), respiratory rate (RR) levels were recorded. Subjects with dry mouth or face mask lesion were recorded. In all groups, PaO2 and TV measurements were higher at the postoperative first hour than the postoperative zero hour. We found that low-flow CPAP increased PaO2 and SpO2 values more, and TV levels were higher in the postoperative period than the preoperative period. PaCO2 levels were elevated at the zero hour postoperatively and at the end of the first hour; they decreased approximately to preoperative values, except in the fourth group. Administration of prophylactic respiratory support can prevent the deterioration of pulmonary functions and hypoxia in patients with COPD undergoing upper abdominal surgery. In addition, we found that low-flow CPAP had better effects on PaO2, SpO2, TV compared to other techniques.

  6. Blood, sweat and plaster casts: Reviewing the history, composition, and scientific value of the Raymond A. Dart Collection of African Life and Death Masks.

    Science.gov (United States)

    Houlton, T M R; Billings, B K

    2017-10-01

    This paper addresses the history, composition and scientific value of one of the most comprehensive facemask collections in Africa, the Raymond A. Dart Collection of African Life and Death Masks. Housed within the School of Anatomical Sciences at the University of the Witwatersrand (South Africa), it comprises 1110 masks (397 life, 487 death, 226 unknown). Life masks represent populations throughout Africa; death masks predominately southern Africa. Males preponderate by 75%. Recorded ages are error prone, but suggest most life masks are those of <35 year-olds, death masks of 36+ year-olds. A total of 241 masks have associated skeletons, 209 presenting a complete skull. Life masks date between 1927 and c.1980s, death masks 1933 and 1963. This historical collection presents uncanny associations with outmoded typological and evolutionary theories. Once perceived an essential scientific resource, performed craniofacial superimpositions identify the nose as the only stable feature maintained, with the remaining face best preserved in young individuals with minimal body fat. The facemask collection is most viable for teaching and research within the history of science, specifically physical anthropology, and presents some value to craniofacial identification. Future research will have to be conducted with appropriate ethical considerations to science and medicine. Copyright © 2017 Elsevier GmbH. All rights reserved.

  7. [Recognition of visual objects under forward masking. Effects of cathegorial similarity of test and masking stimuli].

    Science.gov (United States)

    Gerasimenko, N Iu; Slavutskaia, A V; Kalinin, S A; Kulikov, M A; Mikhaĭlova, E S

    2013-01-01

    In 38 healthy subjects accuracy and response time were examined during recognition of two categories of images--animals andnonliving objects--under forward masking. We revealed new data that masking effects depended of categorical similarity of target and masking stimuli. The recognition accuracy was the lowest and the response time was the most slow, when the target and masking stimuli belongs to the same category, that was combined with high dispersion of response times. The revealed effects were more clear in the task of animal recognition in comparison with the recognition of nonliving objects. We supposed that the revealed effects connected with interference between cortical representations of the target and masking stimuli and discussed our results in context of cortical interference and negative priming.

  8. The respiratory microbiome and respiratory infections

    NARCIS (Netherlands)

    Unger, Stefan A.; Bogaert, Debby

    2017-01-01

    Despite advances over the past ten years lower respiratory tract infections still comprise around a fifth of all deaths worldwide in children under five years of age with the majority in low- and middle-income countries. Known risk factors for severe respiratory infections and poor chronic

  9. Endogenous cueing attenuates object substitution masking.

    Science.gov (United States)

    Germeys, Filip; Pomianowska, I; De Graef, P; Zaenen, P; Verfaillie, K

    2010-07-01

    Object substitution masking (OSM) is a form of visual masking in which a briefly presented target surrounded by four small dots is masked by the continuing presence of the four dots after target offset. A major parameter in the prediction of OSM is the time required for attention to be directed to the target following its onset. Object substitution theory (Di Lollo et al. in J Exp Psychol Gen 129:481-507, 2000) predicts that the sooner attention can be focused at the target's location, the less masking will ensue. However, recently Luiga and Bachmann (Psychol Res 71:634-640, 2007) presented evidence that precueing of attention to the target location prior to target-plus-mask onset by means of a central (endogenous) arrow cue does not reduce OSM. When attention was cued exogenously, OSM was attenuated. Based on these results, Luiga and Bachmann argued that object substitution theory should be adapted by differentiating the ways of directing attention to the target location. The goal of the present study was to further examine the dissociation between the effects of endogenous and exogenous precueing on OSM. Contrary to Luiga and Bachmann, our results show that prior shifts of attention to the target location initiated by both exogenous and endogenous cues reduce OSM as predicted by object substitution theory and its computational model CMOS.

  10. Mitigating mask roughness via pupil filtering

    Science.gov (United States)

    Baylav, B.; Maloney, C.; Levinson, Z.; Bekaert, J.; Vaglio Pret, A.; Smith, B.

    2014-03-01

    The roughness present on the sidewalls of lithographically defined patterns imposes a very important challenge for advanced technology nodes. It can originate from the aerial image or the photoresist chemistry/processing [1]. The latter remains to be the dominant group in ArF and KrF lithography; however, the roughness originating from the mask transferred to the aerial image is gaining more attention [2-9], especially for the imaging conditions with large mask error enhancement factor (MEEF) values. The mask roughness contribution is usually in the low frequency range, which is particularly detrimental to the device performance by causing variations in electrical device parameters on the same chip [10-12]. This paper explains characteristic differences between pupil plane filtering in amplitude and in phase for the purpose of mitigating mask roughness transfer under interference-like lithography imaging conditions, where onedirectional periodic features are to be printed by partially coherent sources. A white noise edge roughness was used to perturbate the mask features for validating the mitigation.

  11. EUV mask process specifics and development challenges

    Science.gov (United States)

    Nesladek, Pavel

    2014-07-01

    EUV lithography is currently the favorite and most promising candidate among the next generation lithography (NGL) technologies. Decade ago the NGL was supposed to be used for 45 nm technology node. Due to introduction of immersion 193nm lithography, double/triple patterning and further techniques, the 193 nm lithography capabilities was greatly improved, so it is expected to be used successfully depending on business decision of the end user down to 10 nm logic. Subsequent technology node will require EUV or DSA alternative technology. Manufacturing and especially process development for EUV technology requires significant number of unique processes, in several cases performed at dedicated tools. Currently several of these tools as e.g. EUV AIMS or actinic reflectometer are not available on site yet. The process development is done using external services /tools with impact on the single unit process development timeline and the uncertainty of the process performance estimation, therefore compromises in process development, caused by assumption about similarities between optical and EUV mask made in experiment planning and omitting of tests are further reasons for challenges to unit process development. Increased defect risk and uncertainty in process qualification are just two examples, which can impact mask quality / process development. The aim of this paper is to identify critical aspects of the EUV mask manufacturing with respect to defects on the mask with focus on mask cleaning and defect repair and discuss the impact of the EUV specific requirements on the experiments needed.

  12. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    2008-11-08

    Nov 8, 2008 ... Pulmonary gas exchange and ventilation were analysed with ... dioxide production (VCO2), minute ventilation (VE), respiratory rate. (fR) and .... Protective masks typically have a dead space of 150 - 500 ml and flow resistance of 8.0. - 10.0 cm H2O∙l-1∙s-1 compared with 70 - 150 ml dead space and 0.6 -.

  13. High-dimensional cluster analysis with the Masked EM Algorithm

    Science.gov (United States)

    Kadir, Shabnam N.; Goodman, Dan F. M.; Harris, Kenneth D.

    2014-01-01

    Cluster analysis faces two problems in high dimensions: first, the “curse of dimensionality” that can lead to overfitting and poor generalization performance; and second, the sheer time taken for conventional algorithms to process large amounts of high-dimensional data. We describe a solution to these problems, designed for the application of “spike sorting” for next-generation high channel-count neural probes. In this problem, only a small subset of features provide information about the cluster member-ship of any one data vector, but this informative feature subset is not the same for all data points, rendering classical feature selection ineffective. We introduce a “Masked EM” algorithm that allows accurate and time-efficient clustering of up to millions of points in thousands of dimensions. We demonstrate its applicability to synthetic data, and to real-world high-channel-count spike sorting data. PMID:25149694

  14. Class III treatment using facial mask: Stability after 10 years

    Directory of Open Access Journals (Sweden)

    Adilson Luiz Ramos

    2014-10-01

    Full Text Available Early Class III malocclusion treatment may not have long-term stability due to mandibular growth. Although some features of this malocclusion point to a better prognosis, it is practically impossible for the orthodontist to foresee cases that require new intervention. Many patients need retreatment, whether compensatory or orthodontic-surgical. The present study reports the case of a Class III patient treated at the end of the mixed dentition with the use of a face mask followed by conventional fixed appliances. The case remains stable 10 years after treatment completion. It was presented to the Brazilian Board of Orthodontics and Dentofacial Orthopedics (BBO as a requirement for the title of certified by the BBO.

  15. Respiratory Syncytial Virus

    Science.gov (United States)

    ... with facebook share with twitter share with linkedin Respiratory Syncytial Virus (RSV) Credit: CDC This is the ... the United States. Why Is the Study of Respiratory Syncytial Virus (RSV) a Priority for NIAID? In ...

  16. Respiratory syncytial virus (RSV)

    Science.gov (United States)

    RSV; Palivizumab; Respiratory syncytial virus immune globulin; Bronchiolitis - RSV ... Crowe JE. Respiratory syncytial virus. In: Kliegman RM, Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ...

  17. Respiratory Issues in OI

    Science.gov (United States)

    Respiratory Issues in Osteogenesis Imperfecta \\ Introduction The respiratory system’s job is to bring oxygen into the body and remove carbon dioxide, the waste product of breathing. Because oxygen is the fuel ...

  18. Acute respiratory distress syndrome

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/000103.htm Acute respiratory distress syndrome To use the sharing features on this page, please enable JavaScript. Acute respiratory distress syndrome (ARDS) is a life-threatening lung ...

  19. Upper respiratory tract (image)

    Science.gov (United States)

    The major passages and structures of the upper respiratory tract include the nose or nostrils, nasal cavity, mouth, throat (pharynx), and voice box (larynx). The respiratory system is lined with a mucous membrane that ...

  20. Avian respiratory system disorders

    Science.gov (United States)

    Olsen, Glenn H.

    1989-01-01

    Diagnosing and treating respiratory diseases in avian species requires a basic knowledge about the anatomy and physiology of this system in birds. Differences between mammalian and avian respiratory system function, diagnosis, and treatment are highlighted.

  1. Famous face recognition, face matching, and extraversion.

    Science.gov (United States)

    Lander, Karen; Poyarekar, Siddhi

    2015-01-01

    It has been previously established that extraverts who are skilled at interpersonal interaction perform significantly better than introverts on a face-specific recognition memory task. In our experiment we further investigate the relationship between extraversion and face recognition, focusing on famous face recognition and face matching. Results indicate that more extraverted individuals perform significantly better on an upright famous face recognition task and show significantly larger face inversion effects. However, our results did not find an effect of extraversion on face matching or inverted famous face recognition.

  2. Catheter and Laryngeal Mask Endotracheal Surfactant Therapy: the CALMEST approach as a novel MIST technique.

    Science.gov (United States)

    Vannozzi, Ilaria; Ciantelli, Massimiliano; Moscuzza, Francesca; Scaramuzzo, Rosa T; Panizza, Davide; Sigali, Emilio; Boldrini, Antonio; Cuttano, Armando

    2017-10-01

    Neonatal respiratory distress syndrome (RDS) is a major cause of mortality and morbidity among preterm infants. Although the INSURE (INtubation, SURfactant administration, Estubation) technique for surfactant replacement therapy is so far the gold standard method, over the last years new approaches have been studied, i.e. less invasive surfactant administration (LISA) or minimally invasive surfactant therapy (MIST). Here we propose an originally modified MIST, called CALMEST (Catheter And Laryngeal Mask Endotracheal Surfactant Therapy), using a particular laryngeal mask as a guide for a thin catheter to deliver surfactant directly in the trachea. We performed a preliminary study on a mannequin and a subsequent in vivo pilot trial. This novel procedure is quick, effective and well tolerated and might represent an improvement in reducing neonatal stress. Ultimately, CALMEST offers an alternative approach that could be extremely useful for medical staff with low expertise in laryngoscopy and intubation.

  3. Improved Mask Protected DES using RSA Algorithm

    Directory of Open Access Journals (Sweden)

    Asha Latha S.

    2016-01-01

    Full Text Available The data encryption standard is a pioneering and farsighted standard which helped to set a new paradigm for encryption standards. But now DES is considered to be insecure for some application. Asymmetric mask protected DES is an advanced encryption method for effectively protecting the advanced DES. There are still probabilities to improve its security. This paper propose a method, which introduce a RSA key generation scheme in mask protected DES instead of plain key, which result in enhancement in the security of present asymmetric mask protected DES. We further propose a Vedic mathematical method of RSA implementation which reduce the complexity of computation in RSA block thereby resulting in reduced delay (four timesthat improves the performance of overall system. The software implementation was performed using Xilinx 13.2 and Model-Sim was used for the simulation environment.

  4. Pattern transfer with stabilized nanoparticle etch masks

    International Nuclear Information System (INIS)

    Hogg, Charles R; Majetich, Sara A; Picard, Yoosuf N; Narasimhan, Amrit; Bain, James A

    2013-01-01

    Self-assembled nanoparticle monolayer arrays are used as an etch mask for pattern transfer into Si and SiO x substrates. Crack formation within the array is prevented by electron beam curing to fix the nanoparticles to the substrate, followed by a brief oxygen plasma to remove excess carbon. This leaves a dot array of nanoparticle cores with a minimum gap of 2 nm. Deposition and liftoff can transform the dot array mask into an antidot mask, where the gap is determined by the nanoparticle core diameter. Reactive ion etching is used to transfer the dot and antidot patterns into the substrate. The effect of the gap size on the etching rate is modeled and compared with the experimental results. (paper)

  5. Counteracting Power Analysis Attacks by Masking

    Science.gov (United States)

    Oswald, Elisabeth; Mangard, Stefan

    The publication of power analysis attacks [12] has triggered a lot of research activities. On the one hand these activities have been dedicated toward the development of secure and efficient countermeasures. On the other hand also new and improved attacks have been developed. In fact, there has been a continuous arms race between designers of countermeasures and attackers. This chapter provides a brief overview of the state-of-the art in the arms race in the context of a countermeasure called masking. Masking is a popular countermeasure that has been extensively discussed in the scientific community. Numerous articles have been published that explain different types of masking and that analyze weaknesses of this countermeasure.

  6. Individual differences in metacontrast masking regarding sensitivity and response bias.

    Science.gov (United States)

    Albrecht, Thorsten; Mattler, Uwe

    2012-09-01

    In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Design of TOPAZ masking system using EGS4

    International Nuclear Information System (INIS)

    Uno, Shoji

    1991-01-01

    There are two sources of the beam background in the e + e - collider experiments. One source is the synchrotron radiation from many magnets. Another source comes from the spent-electron hitting the beam pipe near the interaction region. To reduce the these background, TOPAZ masking system was designed using EGS4 code. The designed masking system consists of two pairs of masks which are called mask-1 and mask-2. The mask-1 is placed to intercept the spent-electron. The aperture of the mask-2 was determined for the synchrotron radiation photons not to hit the mask-1 directly. After these masks were installed, we are taking the data in the small beam background. (author)

  8. Metacontrast masking is processed before grapheme-color synesthesia.

    Science.gov (United States)

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  9. Demagnifying electron projection with grid masks

    International Nuclear Information System (INIS)

    Politycki, A.; Meyer, A.

    1978-01-01

    Tightly toleranced micro- and submicrostructures with smooth edges were realized by using transmission masks with an improved supporting grid (width of traverses 0.8 μm). Local edge shift due to the proximity effect is kept at a minimum. Supporting grids with stil narrower traverses (0.5 μm) were prepared by generating the grid pattern by electron beam writing. Masks of this kind allow projection at a demagnification ratio of 1:4, resulting in large image fields. (orig.) [de

  10. The pros and cons of masked priming.

    Science.gov (United States)

    Forster, K I

    1998-03-01

    Masked priming paradigms offer the promise of tapping automatic, strategy-free lexical processing, as evidenced by the lack of expectancy disconfirmation effects, and proportionality effects in semantic priming experiments. But several recent findings suggest the effects may be prelexical. These findings concern nonword priming effects in lexical decision and naming, the effects of mixed-case presentation on nonword priming, and the dependence of priming on the nature of the distractors in lexical decision, suggesting possible strategy effects. The theory underlying each of these effects is discussed, and alternative explanations are developed that do not preclude a lexical basis for masked priming effects.

  11. What Is Respiratory Distress Syndrome?

    Science.gov (United States)

    ... Home / Respiratory Distress Syndrome Respiratory Distress Syndrome Also known as What Is Respiratory ... This condition is called apnea (AP-ne-ah). Respiratory Distress Syndrome Complications Depending on the severity of ...

  12. Severe acute respiratory syndrome (SARS)

    Science.gov (United States)

    SARS; Respiratory failure - SARS ... Complications may include: Respiratory failure Liver failure Heart failure ... 366. McIntosh K, Perlman S. Coronaviruses, including severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS). ...

  13. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  14. Cosmic Ballet or Devil's Mask?

    Science.gov (United States)

    2004-04-01

    Stars like our Sun are members of galaxies, and most galaxies are themselves members of clusters of galaxies. In these, they move around among each other in a mostly slow and graceful ballet. But every now and then, two or more of the members may get too close for comfort - the movements become hectic, sometimes indeed dramatic, as when galaxies end up colliding. ESO PR Photo 12/04 shows an example of such a cosmic tango. This is the superb triple system NGC 6769-71, located in the southern Pavo constellation (the Peacock) at a distance of 190 million light-years. This composite image was obtained on April 1, 2004, the day of the Fifth Anniversary of ESO's Very Large Telescope (VLT). It was taken in the imaging mode of the VIsible Multi-Object Spectrograph (VIMOS) on Melipal, one of the four 8.2-m Unit Telescopes of the VLT at the Paranal Observatory (Chile). The two upper galaxies, NGC 6769 (upper right) and NGC 6770 (upper left), are of equal brightness and size, while NGC 6771 (below) is about half as bright and slightly smaller. All three galaxies possess a central bulge of similar brightness. They consist of elderly, reddish stars and that of NGC 6771 is remarkable for its "boxy" shape, a rare occurrence among galaxies. Gravitational interaction in a small galaxy group NGC 6769 is a spiral galaxy with very tightly wound spiral arms, while NGC 6770 has two major spiral arms, one of which is rather straight and points towards the outer disc of NGC 6769. NGC 6770 is also peculiar in that it presents two comparatively straight dark lanes and a fainter arc that curves towards the third galaxy, NGC 6771 (below). It is also obvious from this new VLT photo that stars and gas have been stripped off NGC 6769 and NGC 6770, starting to form a common envelope around them, in the shape of a Devil's Mask. There is also a weak hint of a tenuous bridge between NGC 6769 and NGC 6771. All of these features testify to strong gravitational interaction between the three galaxies

  15. Are Masking-Based Models of Risk Useful?

    Science.gov (United States)

    Gisiner, Robert C

    2016-01-01

    As our understanding of directly observable effects from anthropogenic sound exposure has improved, concern about "unobservable" effects such as stress and masking have received greater attention. Equal energy models of masking such as power spectrum models have the appeal of simplicity, but do they offer biologically realistic assessments of the risk of masking? Data relevant to masking such as critical ratios, critical bandwidths, temporal resolution, and directional resolution along with what is known about general mammalian antimasking mechanisms all argue for a much more complicated view of masking when making decisions about the risk of masking inherent in a given anthropogenic sound exposure scenario.

  16. High quality mask storage in an advanced Logic-Fab

    Science.gov (United States)

    Jähnert, Carmen; Fritsche, Silvio

    2012-02-01

    High efficient mask logistics as well as safe and high quality mask storage are essential requirements within an advanced lithography area of a modern logic waferfab. Fast operational availability of the required masks at the exposure tool with excellent mask condition requires a safe mask handling, safeguarding of high mask quality over the whole mask usage time without any quality degradation and an intelligent mask logistics. One big challenge is the prevention of haze on high advanced phase shift masks used in a high volume production line for some thousands of 248nm or 193nm exposures. In 2008 Infineon Dresden qualified a customer specific developed semi-bare mask storage system from DMSDynamic Micro Systems in combination with a high advanced mask handling and an interconnected complex logistic system. This high-capacity mask storage system DMS M1900.22 for more than 3000 masks with fully automated mask and box handling as well as full-blown XCDA purge has been developed and adapted to the Infineon Lithotoollandscape using Nikon and SMIF reticle cases. Advanced features for ESD safety and mask security, mask tracking via RFID and interactions with the exposure tools were developed and implemented. The stocker is remote controlled by the iCADA-RSM system, ordering of the requested mask directly from the affected exposure tool allows fast access. This paper discusses the advantages and challenges for this approach as well as the practical experience gained during the implementation of the new system which improves the fab performance with respect to mask quality, security and throughput. Especially the realization of an extremely low and stable humidity level in addition with a well controlled air flow at each mask surface, preventing masks from haze degradation and particle contamination, turns out to be a notable technical achievement. The longterm stability of haze critical masks has been improved significantly. Relevant environmental parameters like

  17. Virtual & Real Face to Face Teaching

    Science.gov (United States)

    Teneqexhi, Romeo; Kuneshka, Loreta

    2016-01-01

    In traditional "face to face" lessons, during the time the teacher writes on a black or white board, the students are always behind the teacher. Sometimes, this happens even in the recorded lesson in videos. Most of the time during the lesson, the teacher shows to the students his back not his face. We do not think the term "face to…

  18. Monitoring tidal volumes in preterm infants at birth: mask versus endotracheal ventilation.

    Science.gov (United States)

    van Vonderen, Jeroen J; Hooper, Stuart B; Krabbe, Vera B; Siew, Melissa L; Te Pas, Arjan B

    2015-01-01

    Upper airway distention during mask ventilation could reduce gas volumes entering the lung compared with ventilation via an endotracheal tube. Therefore, respiratory tract volumes were measured in lambs and tidal volumes were compared in preterm infants before and after intubation. In seven preterm lambs, volumes of the airways (oropharynx, trachea, lungs) were assessed. In 10 preterm infants, delta pressures, tidal volumes and leak were measured during ventilation 2 min before (mask ventilation) and 2 min after intubation (endotracheal ventilation). Inflations coinciding with breaths were excluded. Amount of upper airway distention in lambs and differences in inspiratory and expiratory tidal volume before and after intubation. In lambs, the combined trachea and oropharynx contributed to 14 (12-21) % (median (IQR), whereas the oropharynx contributed to 9 (7-10) % of the total tidal volume measured at the mouth. In preterm infants, inspiratory (11.1 (7.9-22.6) mL/kg vs 5.8 (3.9-9.6) mL/kg (p=0.01)) and expiratory (8.3 (6.8-15.4) mL/kg vs 4.9 (3.9-9.6) mL/kg (p=0.02)) tidal volumes were significantly larger during mask ventilation compared with endotracheal ventilation. Leak was 18.7 (3.3-28.7) % before versus 0 (0-2.3) % after intubation (p0.05). During mask ventilation, expiratory tidal volume increased from 10.0 (5.4-15.6) mL/kg to 11.3 (7.6-17.0) mL/kg (p=0.01), but remained unchanged during endotracheal ventilation. During neonatal mask ventilation, distention of the upper respiratory tract contributes to the tidal volumes measured and should be taken into account when targeting tidal volumes during mask ventilation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Embedded Face Detection and Recognition

    Directory of Open Access Journals (Sweden)

    Göksel Günlü

    2012-10-01

    Full Text Available The need to increase security in open or public spaces has in turn given rise to the requirement to monitor these spaces and analyse those images on-site and on-time. At this point, the use of smart cameras – of which the popularity has been increasing – is one step ahead. With sensors and Digital Signal Processors (DSPs, smart cameras generate ad hoc results by analysing the numeric images transmitted from the sensor by means of a variety of image-processing algorithms. Since the images are not transmitted to a distance processing unit but rather are processed inside the camera, it does not necessitate high-bandwidth networks or high processor powered systems; it can instantaneously decide on the required access. Nonetheless, on account of restricted memory, processing power and overall power, image processing algorithms need to be developed and optimized for embedded processors. Among these algorithms, one of the most important is for face detection and recognition. A number of face detection and recognition methods have been proposed recently and many of these methods have been tested on general-purpose processors. In smart cameras – which are real-life applications of such methods – the widest use is on DSPs. In the present study, the Viola-Jones face detection method – which was reported to run faster on PCs – was optimized for DSPs; the face recognition method was combined with the developed sub-region and mask-based DCT (Discrete Cosine Transform. As the employed DSP is a fixed-point processor, the processes were performed with integers insofar as it was possible. To enable face recognition, the image was divided into sub-regions and from each sub-region the robust coefficients against disruptive elements – like face expression, illumination, etc. – were selected as the features. The discrimination of the selected features was enhanced via LDA (Linear Discriminant Analysis and then employed for recognition. Thanks to its

  20. Evaluation of a new pediatric positive airway pressure mask.

    Science.gov (United States)

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  1. Micropatterning on cylindrical surfaces via electrochemical etching using laser masking

    International Nuclear Information System (INIS)

    Cho, Chull Hee; Shin, Hong Shik; Chu, Chong Nam

    2014-01-01

    Highlights: • Various micropatterns were fabricated on the cylindrical surface of a stainless steel shaft. • Selective electrochemical dissolution was achieved via a series process of laser masking and electrochemical etching. • Laser masking characteristics on the non-planar surface were investigated. • A uniform mask layer was formed on the cylindrical surface via synchronized laser line scanning with a rotary system. • The characteristics of electrochemical etching on the non-planar surface were investigated. - Abstract: This paper proposes a method of selective electrochemical dissolution on the cylindrical surfaces of stainless steel shafts. Selective electrochemical dissolution was achieved via electrochemical etching using laser masking. A micropatterned recast layer was formed on the surface via ytterbium-doped pulsed fiber laser irradiation. The micropatterned recast layer could be used as a mask layer during the electrochemical etching process. Laser masking condition to form adequate mask layer on the planar surface for etching cannot be used directly on the non-planar surface. Laser masking condition changes depending on the morphological surface. The laser masking characteristics were investigated in order to form a uniform mask layer on the cylindrical surface. To minimize factors causing non-uniformity in the mask layer on the cylindrical surface, synchronized laser line scanning with a rotary system was applied during the laser masking process. Electrochemical etching characteristics were also investigated to achieve deeper etched depth, without collapsing the recast layer. Consequently, through a series process of laser masking and electrochemical etching, various micropatternings were successfully performed on the cylindrical surfaces

  2. Posleslovije k "Zolotoi maske" / Boris Tuch

    Index Scriptorium Estoniae

    Tuch, Boris, 1946-

    2005-01-01

    Vene draamafestivali "Kuldne mask Eestis" lavastusest : "September.doc", lav. Mihhail Ugarov, I. Võrõpajevi "Hapnik" lav. Viktor Rõzhakov Teatr.doc esituses, Sophoklese "Kuningas Oidipus" lav. Andrei Prikotenko Peterburi Teatri Liteinõi esituses, M. Ugarovi lavastus "OblomOFF"

  3. Using excitation patterns to predict auditory masking

    NARCIS (Netherlands)

    Heijden, van der M.L.; Kohlrausch, A.G.

    1992-01-01

    We investigated how well auditory masking can be predicted from excitation patterns. For this purpose, a quantitative model proposed by Moore and Glasberg (1987) and Glasberg and Moore (1990) was used to calculate excitation patterns evoked by stationary sounds. We performed simulations of a number

  4. Central auditory masking by an illusory tone.

    Directory of Open Access Journals (Sweden)

    Christopher J Plack

    Full Text Available Many natural sounds fluctuate over time. The detectability of sounds in a sequence can be reduced by prior stimulation in a process known as forward masking. Forward masking is thought to reflect neural adaptation or neural persistence in the auditory nervous system, but it has been unclear where in the auditory pathway this processing occurs. To address this issue, the present study used a "Huggins pitch" stimulus, the perceptual effects of which depend on central auditory processing. Huggins pitch is an illusory tonal sensation produced when the same noise is presented to the two ears except for a narrow frequency band that is different (decorrelated between the ears. The pitch sensation depends on the combination of the inputs to the two ears, a process that first occurs at the level of the superior olivary complex in the brainstem. Here it is shown that a Huggins pitch stimulus produces more forward masking in the frequency region of the decorrelation than a noise stimulus identical to the Huggins-pitch stimulus except with perfect correlation between the ears. This stimulus has a peripheral neural representation that is identical to that of the Huggins-pitch stimulus. The results show that processing in, or central to, the superior olivary complex can contribute to forward masking in human listeners.

  5. Testing Tactile Masking between the Forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2016-02-10

    Masking, in which one stimulus affects the detection of another, is a classic technique that has been used in visual, auditory, and tactile research, usually using stimuli that are close together to reveal local interactions. Masking effects have also been demonstrated in which a tactile stimulus alters the perception of a touch at a distant location. Such effects can provide insight into how components of the body's representations in the brain may be linked. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at corresponding contralateral locations. To explore the matching of corresponding points across the body, we can measure the spatial tuning and effect of posture on contralateral masking. Careful controls are required to rule out direct effects of the remote stimulus, for example by mechanical transmission, and also attention effects in which thresholds may be altered by the participant's attention being drawn away from the stimulus of interest. The use of this technique is beneficial as a behavioural measure for exploring which parts of the body are functionally connected and whether the two sides of the body interact in a somatotopic representation. This manuscript describes a behavioural protocol that can be used for studying contralateral tactile masking.

  6. Software error masking effect on hardware faults

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Seong, Poong Hyun

    1999-01-01

    Based on the Very High Speed Integrated Circuit (VHSIC) Hardware Description Language (VHDL), in this work, a simulation model for fault injection is developed to estimate the dependability of the digital system in operational phase. We investigated the software masking effect on hardware faults through the single bit-flip and stuck-at-x fault injection into the internal registers of the processor and memory cells. The fault location reaches all registers and memory cells. Fault distribution over locations is randomly chosen based on a uniform probability distribution. Using this model, we have predicted the reliability and masking effect of an application software in a digital system-Interposing Logic System (ILS) in a nuclear power plant. We have considered four the software operational profiles. From the results it was found that the software masking effect on hardware faults should be properly considered for predicting the system dependability accurately in operation phase. It is because the masking effect was formed to have different values according to the operational profile

  7. Shadow mask evaporation through monolayer modified nanostencils

    NARCIS (Netherlands)

    Kolbel, M.; Tjerkstra, R.W.; Brugger, J.P.; van Rijn, C.J.M.; Nijdam, W.; Huskens, Jurriaan; Reinhoudt, David

    2002-01-01

    Gradual clogging of the apertures of nanostencils used as miniature shadow masks in metal evaporations can be reduced by coating the stencil with self-assembled monolayers (SAM). This is quantified by the dimensions (height and volume) of gold features obtained by nanostencil evaporation as measured

  8. Method for coating substrates and mask holder

    NARCIS (Netherlands)

    Bijkerk, Frederik; Yakshin, Andrey; Louis, Eric; Kessels, M.J.H.; Maas, Edward Lambertus Gerardus; Bruineman, Caspar

    2004-01-01

    When coating substrates it is frequently desired that the layer thickness should be a certain function of the position on the substrate to be coated. To control the layer thickness a mask is conventionally arranged between the coating particle source and the substrate. This leads to undesirable

  9. Parallel Implementation of the Terrain Masking Algorithm

    Science.gov (United States)

    1994-03-01

    contains behavior rules which can define a computation or an algorithm. It can communicate with other process nodes, it can contain local data, and it can...terrain maskirg calculation is being performed. It is this algorithm that comsumes about seventy percent of the total terrain masking calculation time

  10. Novel Seals and Specialty Component Attachment Mechanisms for Respiratory Protection System (RESPO 21)

    Science.gov (United States)

    1992-10-01

    use in a warm clima ,, Ao~ hccts rovcf rur % Cr. ugc na il oimnte nber o prna in ntting materil coupled to skin separat lc~oe tect wocn f h~i. Sae...the mask shell on the side vagina and cervix of a woman in labor , electrode meam &h thereof facing the face. said sealing tube having a fixed sealed

  11. Green binary and phase shifting mask

    Science.gov (United States)

    Shy, S. L.; Hong, Chao-Sin; Wu, Cheng-San; Chen, S. J.; Wu, Hung-Yu; Ting, Yung-Chiang

    2009-12-01

    SixNy/Ni thin film green mask blanks were developed , and are now going to be used to replace general chromium film used for binary mask as well as to replace molydium silicide embedded material for AttPSM for I-line (365 nm), KrF (248 nm), ArF (193 nm) and Contact/Proximity lithography. A bilayer structure of a 1 nm thick opaque, conductive nickel layer and a SixNy layer is proposed for binary and phase-shifting mask. With the good controlling of plasma CVD of SixNy under silane (50 sccm), ammonia (5 sccm) and nitrogen (100 sccm), the pressure is 250 mTorr. and RF frequency 13.56 MHz and power 50 W. SixNy has enough deposition latitude to meet the requirements as an embedded layer for required phase shift 180 degree, and the T% in 193, 248 and 365 nm can be adjusted between 2% to 20% for binary and phase shifting mask usage. Ni can be deposited by E-gun, its sheet resistance Rs is less than 1.435 kΩ/square. Jeol e-beam system and I-line stepper are used to evaluate these thin film green mask blanks, feature size less than 200 nm half pitch pattern and 0.558 μm pitch contact hole can be printed. Transmission spectrums of various thickness of SixNy film are inspected by using UV spectrometer and FTIR. Optical constants of the SixNy film are measured by n & k meter and surface roughness is inspected by using Atomic Force Microscope (AFM).

  12. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    Science.gov (United States)

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  13. Mask_explorer: A tool for exploring brain masks in fMRI group analysis.

    Science.gov (United States)

    Gajdoš, Martin; Mikl, Michal; Mareček, Radek

    2016-10-01

    Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Congenital asymmetric crying face: a case report

    Directory of Open Access Journals (Sweden)

    Semra Kara

    2011-12-01

    Full Text Available Congenital asymmetric crying face is an anomalia caused by unilateral absence or weakness of depressor anguli oris muscle The major finding of the disease is the absence or weakness in the outer and lower movement of the commissure during crying. The other expression muscles are normal and the face is symmetric at rest. The asymmetry in congenital asymmetric crying face is most evident during infancy but decreases by age. Congenital asymmetric crying face can be associated with cervicofacial, musclebone, respiratory, genitourinary and central nervous system anomalia. It is diagnosed by physical examination. This paper presents a six days old infant with Congenital asymmetric crying face and discusses the case in terms of diagnosis and disease features.

  15. Scatterometry on pelliclized masks: an option for wafer fabs

    Science.gov (United States)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  16. Comparison of monaural (CMR) and binaural (BMLD) masking release

    NARCIS (Netherlands)

    Par, van de S.L.J.D.E.; Kohlrausch, A.G.

    1998-01-01

    Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz

  17. 21 CFR 868.5550 - Anesthetic gas mask.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic gas mask. 868.5550 Section 868.5550...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5550 Anesthetic gas mask. (a) Identification. An anesthetic gas mask is a device, usually made of conductive rubber, that is positioned over a...

  18. The value of high-flow nasal cannula oxygen therapy after extubation in patients with acute respiratory failure

    Directory of Open Access Journals (Sweden)

    Hong-Zhuan Song

    Full Text Available OBJECTIVE: To investigate the value of high-flow nasal cannula oxygen therapy after extubation in patients with acute respiratory failure. METHODS: A single-center, prospective, randomized, controlled pilot trial was conducted between January 2013 and December 2014. Sixty enrolled patients were randomized immediately after extubation into either a high-flow nasal cannula group (n=30 or an air entrainment mask group (n=30 at a fixed inspired oxygen fraction (40%. The success rate of oxygen therapy, respiratory and hemodynamic parameters and subjective discomfort (using a visual analogue scale were assessed at 24h after extubation. RESULTS: The two groups were comparable at extubation. A total of 46 patients were successfully treated including 27 patients in the high-flow nasal cannula group and 19 patients in the air entrainment mask group. Compared to the air entrainment mask group, the success rate of oxygen therapy and the partial pressure of arterial oxygen were significantly higher and the respiratory rate was lower in the high-flow nasal cannula group. In addition, less discomfort related to interface displacement and airway dryness was observed in the high-flow nasal cannula group than in the air entrainment mask group. CONCLUSIONS: At a fixed inspired oxygen fraction, the application of a high-flow nasal cannula after extubation achieves a higher success rate of oxygen therapy and less discomfort at 24h than an air entrainment mask in patients with acute respiratory failure.

  19. Neurological Respiratory Failure

    Directory of Open Access Journals (Sweden)

    Mohan Rudrappa

    2018-01-01

    Full Text Available West Nile virus infection in humans is mostly asymptomatic. Less than 1% of neuro-invasive cases show a fatality rate of around 10%. Acute flaccid paralysis of respiratory muscles leading to respiratory failure is the most common cause of death. Although the peripheral nervous system can be involved, isolated phrenic nerve palsy leading to respiratory failure is rare and described in only two cases in the English literature. We present another case of neurological respiratory failure due to West Nile virus-induced phrenic nerve palsy. Our case reiterates the rare, but lethal, consequences of West Nile virus infection, and the increase of its awareness among physicians.

  20. European cinema: face to face with Hollywood

    NARCIS (Netherlands)

    Elsaesser, T.

    2005-01-01

    In the face of renewed competition from Hollywood since the early 1980s and the challenges posed to Europe's national cinemas by the fall of the Wall in 1989, independent filmmaking in Europe has begun to re-invent itself. European Cinema: Face to Face with Hollywood re-assesses the different

  1. A Face Inversion Effect without a Face

    Science.gov (United States)

    Brandman, Talia; Yovel, Galit

    2012-01-01

    Numerous studies have attributed the face inversion effect (FIE) to configural processing of internal facial features in upright but not inverted faces. Recent findings suggest that face mechanisms can be activated by faceless stimuli presented in the context of a body. Here we asked whether faceless stimuli with or without body context may induce…

  2. Contrast Gain Control Model Fits Masking Data

    Science.gov (United States)

    Watson, Andrew B.; Solomon, Joshua A.; Null, Cynthia H. (Technical Monitor)

    1994-01-01

    We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.

  3. Multi-part mask for implanting workpieces

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.

    2016-05-10

    A multi-part mask has a pattern plate, which includes a planar portion that has the desired aperture pattern to be used during workpiece processing. The multi-part mask also has a mounting frame, which is used to hold the pattern plate. Prior to assembly, the pattern plate has an aligning portion, which has one or more holes through which reusable alignment pins are inserted. These alignment pins enter kinematic joints disposed on the mounting frame, which serve to precisely align the pattern plate to the mounting frame. After the pattern plate has been secured to the mounting frame, the aligning portion can be detached from the pattern plate. The alignment pins can be reused at a later time. In some embodiments, the pattern plate can later be removed from the mounting frame, so that the mounting frame may be reused.

  4. Negative ion source improvement by introduction of a shutter mask

    International Nuclear Information System (INIS)

    Belchenko, Yu.I.; Oka, Y.; Kaneko, O.; Takeiri, Y.; Tsumori, K.; Osakabe, M.; Ikeda, K.; Asano, E.; Kawamoto, T.

    2004-01-01

    Studies of a multicusp source were recently done at the National Institute for Fusion Science by plasma grid masking. The maximal H - ion yield is ∼1.4 times greater for the shutter mask case than that for the standard source. Negative ion current evolution during the cesium feed to the masked plasma grid evidenced that about 60% of negative ions are produced on the shutter mask surface, while about 30% are formed on the plasma grid emission hole edges, exposed by cesium with the mask open

  5. Effect of test exercises and mask donning on measured respirator fit.

    Science.gov (United States)

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  6. [Patients' reaction to pharmacists wearing a mask during their consultations].

    Science.gov (United States)

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  7. Contact printed masks for 3D microfabrication in negative resists

    DEFF Research Database (Denmark)

    Häfliger, Daniel; Boisen, Anja

    2005-01-01

    We present a process based on contact printed shadow masks for three dimensional microfabrication of soft and sensitive overhanging membranes in SU-8. A metal mask is transferred onto unexposed SU-8 from an elastomer stamp made of polydimethylsiloxane. This mask is subsequently embedded into the ......We present a process based on contact printed shadow masks for three dimensional microfabrication of soft and sensitive overhanging membranes in SU-8. A metal mask is transferred onto unexposed SU-8 from an elastomer stamp made of polydimethylsiloxane. This mask is subsequently embedded...... into the negative resist to protect buried material from UV-exposure. Unlike direct evaporation-deposition of a mask onto the SU-8, printing avoids high stress and radiation, thus preventing resist wrinkling and prepolymerization. We demonstrate effective monolithic fabrication of soft, 4-μm thick and 100-μm long...

  8. The effect of masking in the attentional dwell time paradigm

    DEFF Research Database (Denmark)

    Petersen, Anders

    2009-01-01

    , 1994). In most studies of attentional dwell time, two masked targets have been used. Moore et al. (1996) have criticised the masking of the first target when measuring the attentional dwell time, finding a shorter attentional dwell time when the first mask was omitted. In the presented work, the effect...... of the first mask is further investigated by including a condition where the first mask is presented without a target. The results from individual subjects show that the findings of Moore et al. can be replicated. The results also suggest that presenting the first mask without a target is enough to produce...... an impairment of the second target. Hence, the attentional dwell time may be a combined effect arising from attending to both the first target and its mask....

  9. APPLICATION OF EQUIPMENT FOR AUTOMATIC CONTROL OF PLANAR STRUCTURES IN MANUFACTURING MASTER MASKS OF INTEGRATED CIRCUITS ON PHOTO-MASKS

    Directory of Open Access Journals (Sweden)

    S. M. Avakov

    2007-01-01

    Full Text Available Following the concept of defect-free manufacturing of master masks of IC on photo-masks, two Belarusian sets of optomechanical equipment for 0,3 5 p and 90 nanometers are presented in the paper. Each of the sets comprises:   • Multi-channel laser pattern generator; • Automatic mask defect inspection system; • Laser-based mask defect repair system.The paper contains description of automatic mask defect inspection process during photo-mask manufacturing and respective basic technological operations of the processes.Advantages of a complex approach to the development of a set of opto-mechanical equipment for defect-free manufacturing of photo-masks have been analyzed in the paper. 

  10. Facing the threat of influenza pandemic - roles of and implications to general practitioners

    Directory of Open Access Journals (Sweden)

    Lee Albert

    2010-11-01

    Full Text Available Abstract The 2009 pandemic of H1N1 influenza, compounded with seasonal influenza, posed a global challenge. Despite the announcement of post-pandemic period on 10 August 2010 by theWHO, H1N1 (2009 virus would continue to circulate as a seasonal virus for some years and national health authorities should remain vigilant due to unpredictable behaviour of the virus. Majority of the world population is living in countries with inadequate resources to purchase vaccines and stockpile antiviral drugs. Basic hygienic measures such as wearing face masks and the hygienic practice of hand washing could reduce the spread of the respiratory viruses. However, the imminent issue is translating these measures into day-to-day practice. The experience from Severe Acute Respiratory Syndrome (SARS in Hong Kong has shown that general practitioners (GPs were willing to discharge their duties despite risks of getting infected themselves. SARS event has highlighted the inadequate interface between primary and secondary care and valuable health care resources were thus inappropriately matched to community needs. There are various ways for GPs to contribute in combating the influenza pandemic. They are prompt in detecting and monitoring epidemics and mini-epidemics of viral illnesses in the community. They can empower and raise the health literacy of the community such as advocating personal hygiene and other precautious measures. GPs could also assist in the development of protocols for primary care management of patients with flu-like illnesses and conduct clinical audits on the standards of preventive and treatment measures. GPs with adequate liaison with public health agencies would facilitate early diagnosis of patients with influenza. In this article, we summarise the primary care actions for phases 4-6 of the pandemic. We shall discuss the novel roles of GPs as alternative source of health care for patients who would otherwise be cared for in the secondary care

  11. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    Science.gov (United States)

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  12. A new method of maintaining airway during nasotracheal intubation--the hand mask technique.

    Science.gov (United States)

    Wu, R S; Wong, D S; Chung, P C; Tan, P P

    1993-09-01

    The efficacy of a new method (The hand mask technique) for airway maintenance during nasotracheal intubation was evaluated in our randomized crossover study. Sixty, age less than 50, ASA physical status class I-II patients undergoing surgery for the extremities with informed consent were randomly chosen for the study. Pulse oximeter, capnometer, EKG, blood pressure monitor and a peripheral nerve stimulator were attached to the patients before induction for continuous monitoring. An arterial cannula was inserted for intermittent blood gas sampling. After baseline room air blood gas data had been obtained from the spontaneously breathing patients, a flow rate of 6L/min pure oxygen was applied through a loosely fitted face mask and a semi-closed anesthesia breathing circuit for a period of 5 minutes. An arterial blood sample was drawn and the patients were put under general anesthesia with full muscle relaxation thereafter. Patients were then randomly assigned into two groups according to the ventilation technique used. Group A patients (n = 30) were manually ventilated first through a face mask for ten minutes and then the hand mask technique for another ten minutes. Blood gas data was sampled and heart rate, blood pressure, peak inspiratory airway pressure and end tidal CO2 were recorded immediately after each ventilation technique. For patients in Group B (n = 30), the sequence of the two ventilation technique were reversed. The results showed significant increases in PaO2 after artificial ventilation in both groups (No significant difference in results between the two groups) and less incidence of nasal bleeding in Group A.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Causal mechanisms of masked hypertension: socio-psychological aspects.

    Science.gov (United States)

    Ogedegbe, Gbenga

    2010-04-01

    The contribution of Dr Thomas Pickering's study to the measurement of blood pressure (BP) is the defining aspect of his academic career and achievement - narrowly defined. In this regard, two important areas characterized his study as it relates to masked hypertension. First, he introduced the term, masked hypertension, to replace the rather inappropriate term 'reverse white-coat hypertension' and 'white-coat normotension'; thus drawing attention to the fact that these patients are genuinely hypertensive by ambulatory BP but were missed by normal office BP. More importantly, he rightly maintained that masked hypertension is a true continuum of sustained hypertension rather than an aberrant measurement artifact. Second, is his pivotal study on the important role of psychosocial factors as a potential mechanism for the development of masked hypertension. In this regard, he explained masked hypertension as a conditioned response to anxiety in office settings, and highlighted the role that diagnostic labeling plays in its development. His view of masked hypertension is that of a continuum from prehypertension (based on office BP measurement) to masked hypertension (based on ambulatory BP) and finally to sustained hypertension (based on both office and ambulatory BP). He strongly believes that it is the prehypertensive patients who progress to masked hypertension. Subsequently, patients who are prehypertensive should be screened for masked hypertension and treated. In this manuscript, we summarize his study as it relates to the definition of masked hypertension, the psychosocial characteristics, mechanisms and its clinical relevance.

  14. Investigating neurophysiological correlates of metacontrast masking with magnetoencephalography

    Directory of Open Access Journals (Sweden)

    Jens Schwarzbach

    2006-01-01

    Full Text Available Early components of visual evoked potentials (VEP in EEG seem to be unaffected by target visibility in visual masking studies. Bridgeman's reanalysis of Jeffreys and Musselwhite's (1986 data suggests that a later visual component in the VEP, around 250 ms reflects the perceptual effect of masking. We challenge this view on the ground that temporal interactions between targets and masks unrelated to stimulus visibility could account for Bridgeman's observation of a U-shaped time course in VEP amplitudes for this later component. In an MEG experiment of metacontrast masking with variable stimulus onset asynchrony, we introduce a proper control, a pseudo mask. In contrast to an effective mask, the pseudomask should produce neither behavioral masking nor amplitude modulations of late VEPs. Our results show that effective masks produced a strong U-shaped perceptual effect of target visibility while performance remained virtually perfect when a pseudomask was used. The visual components around 250 ms after target onset did not show a distinction between mask and pseudomask conditions. The results indicate that these visual evoked potentials do not reveal neurophysiological correlates of stimulus visibility but rather reflect dynamic interactions between superimposed potentials elicited by stimuli in close temporal proximity. However, we observed a postperceptual component around 340 ms after target onset, located over temporal-parietal cortex, which shows a clear effect of visibility. Based on P300 ERP literature, this finding could indicate that working memory related processes contribute to metacontrast masking.

  15. Fabrication of micro- and nano-structured materials using mask-less processes

    International Nuclear Information System (INIS)

    Roy, Sudipta

    2007-01-01

    Micro- and nano-scale devices are used in electronics, micro-electro- mechanical, bio-analytical and medical components. An essential step for the fabrication of such small scale devices is photolithography. Photolithography requires a master mask to transfer micrometre or sub-micrometre scale patterns onto a substrate. The requirement of a physical, rigid mask can impede progress in applications which require rapid prototyping, flexible substrates, multiple alignment and 3D fabrication. Alternative technologies, which do not require the use of a physical mask, are suitable for these applications. In this paper mask-less methods of micro- and nano-scale fabrication have been discussed. The most common technique, which is the laser direct imaging (LDI), technique has been applied to fabricate micrometre scale structures on printed circuit boards, glass and epoxy. LDI can be combined with chemical methods to deposit metals, inorganic materials as well as some organic entities at the micrometre scale. Inkjet technology can be used to fabricate micrometre patterns of etch resists, organic transistors as well as arrays for bioanalysis. Electrohydrodynamic atomisation is used to fabricate micrometre scale ceramic features. Electrochemical methodologies offer a variety of technical solutions for micro- and nano-fabrication owing to the fact that electron charge transfer can be constrained to a solid-liquid interface. Electrochemical printing is an adaptation of inkjet printing which can be used for rapid prototyping of metallic circuits. Micro-machining using nano-second voltage pulses have been used to fabricate high precision features on metals and semiconductors. Optimisation of reactor, electrochemistry and fluid flow (EnFACE) has also been employed to transfer micrometre scale patterns on a copper substrate. Nano-scale features have been fabricated by using specialised tools such as scanning tunnelling microscopy, atomic force microscopy and focused ion beam. The

  16. Non-invasive mechanical ventilation after the successful weaning: a comparison with the venturi mask

    Directory of Open Access Journals (Sweden)

    Esra Adıyeke

    2016-11-01

    Full Text Available Background and objectives: This study compared the rates of acute respiratory failure, reintubation, length of intensive care stay and mortality in patients in whom the non-invasive mechanical ventilation (NIMV was applied instead of the routine venturi face mask (VM application after a successful weaning. Methods: Following the approval of the hospital ethics committee, 62 patients who were under mechanical ventilation for at least 48 hours were scheduled for this study. 12 patients were excluded because of the weaning failure during T-tube trial. The patients who had optimum weaning criteria after the T-tube trial of 30 minutes were extubated. The patients were kept on VM for 1 hour to observe the hemodynamic and respiratory stability. The group of 50 patients who were successful to wean randomly allocated to have either VM (n = 25, or NIV (n = 25. Systolic arterial pressure (SAP, heart rate (HR, respiratory rate (RR, PaO2, PCO2, and pH values were recorded. Results: The number of patients who developed respiratory failure in the NIV group was significantly less than VM group of patients (3 reintubation vs. 14 NIV + 5 reintubation in the VM group. The length of stay in the ICU was also significantly shorter in NIV group (5.2 ± 4.9 vs. 16.7 ± 7.7 days. Conclusions: The ratio of the respiratory failure and the length of stay in the ICU were lower when non-invasive mechanical ventilation was used after extubation even if the patient is regarded as ‘successfully weaned’. We recommend the use of NIMV in such patients to avoid unexpected ventilator failure. Resumo: Justificativa e objetivos: Este estudo comparou as taxas de insuficiência respiratória aguda, reintubação, tempo de internação em UTI e mortalidade em pacientes sob ventilação mecânica não invasiva (VMNI em vez da habitual máscara facial de Venturi (MV após desmame bem-sucedido. Métodos: Após a aprovação do Comitê de Ética do hospital, 62 pacientes que

  17. Attention Capture by Faces

    Science.gov (United States)

    Langton, Stephen R. H.; Law, Anna S.; Burton, A. Mike; Schweinberger, Stefan R.

    2008-01-01

    We report three experiments that investigate whether faces are capable of capturing attention when in competition with other non-face objects. In Experiment 1a participants took longer to decide that an array of objects contained a butterfly target when a face appeared as one of the distracting items than when the face did not appear in the array.…

  18. Respiratory medicine of reptiles.

    Science.gov (United States)

    Schumacher, Juergen

    2011-05-01

    Noninfectious and infectious causes have been implicated in the development of respiratory tract disease in reptiles. Treatment modalities in reptiles have to account for species differences in response to therapeutic agents as well as interpretation of diagnostic findings. Data on effective drugs and dosages for the treatment of respiratory diseases are often lacking in reptiles. Recently, advances have been made on the application of advanced imaging modalities, especially computed tomography for the diagnosis and treatment monitoring of reptiles. This article describes common infectious and noninfectious causes of respiratory disease in reptiles, including diagnostic and therapeutic regimen. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Face detection and facial feature localization using notch based templates

    International Nuclear Information System (INIS)

    Qayyum, U.

    2007-01-01

    We present a real time detection off aces from the video with facial feature localization as well as the algorithm capable of differentiating between the face/non-face patterns. The need of face detection and facial feature localization arises in various application of computer vision, so a lot of research is dedicated to come up with a real time solution. The algorithm should remain simple to perform real time whereas it should not compromise on the challenges encountered during the detection and localization phase, keeping simplicity and all challenges i.e. algorithm invariant to scale, translation, and (+-45) rotation transformations. The proposed system contains two parts. Visual guidance and face/non-face classification. The visual guidance phase uses the fusion of motion and color cues to classify skin color. Morphological operation with union-structure component labeling algorithm extracts contiguous regions. Scale normalization is applied by nearest neighbor interpolation method to avoid the effect of different scales. Using the aspect ratio of width and height size. Region of Interest (ROI) is obtained and then passed to face/non-face classifier. Notch (Gaussian) based templates/ filters are used to find circular darker regions in ROI. The classified face region is handed over to facial feature localization phase, which uses YCbCr eyes/lips mask for face feature localization. The empirical results show an accuracy of 90% for five different videos with 1000 face/non-face patterns and processing rate of proposed algorithm is 15 frames/sec. (author)

  20. Silicon germanium mask for deep silicon etching

    KAUST Repository

    Serry, Mohamed

    2014-07-29

    Polycrystalline silicon germanium (SiGe) can offer excellent etch selectivity to silicon during cryogenic deep reactive ion etching in an SF.sub.6/O.sub.2 plasma. Etch selectivity of over 800:1 (Si:SiGe) may be achieved at etch temperatures from -80 degrees Celsius to -140 degrees Celsius. High aspect ratio structures with high resolution may be patterned into Si substrates using SiGe as a hard mask layer for construction of microelectromechanical systems (MEMS) devices and semiconductor devices.

  1. Geometrical superresolved imaging using nonperiodic spatial masking.

    Science.gov (United States)

    Borkowski, Amikam; Zalevsky, Zeev; Javidi, Bahram

    2009-03-01

    The resolution of every imaging system is limited either by the F-number of its optics or by the geometry of its detection array. The geometrical limitation is caused by lack of spatial sampling points as well as by the shape of every sampling pixel that generates spectral low-pass filtering. We present a novel approach to overcome the low-pass filtering that is due to the shape of the sampling pixels. The approach combines special algorithms together with spatial masking placed in the intermediate image plane and eventually allows geometrical superresolved imaging without relation to the actual shape of the pixels.

  2. Silicon germanium mask for deep silicon etching

    KAUST Repository

    Serry, Mohamed; Rubin, Andrew; Refaat, Mohamed; Sedky, Sherif; Abdo, Mohammad

    2014-01-01

    Polycrystalline silicon germanium (SiGe) can offer excellent etch selectivity to silicon during cryogenic deep reactive ion etching in an SF.sub.6/O.sub.2 plasma. Etch selectivity of over 800:1 (Si:SiGe) may be achieved at etch temperatures from -80 degrees Celsius to -140 degrees Celsius. High aspect ratio structures with high resolution may be patterned into Si substrates using SiGe as a hard mask layer for construction of microelectromechanical systems (MEMS) devices and semiconductor devices.

  3. Individual differences in detecting rapidly presented fearful faces.

    Directory of Open Access Journals (Sweden)

    Dandan Zhang

    Full Text Available Rapid detection of evolutionarily relevant threats (e.g., fearful faces is important for human survival. The ability to rapidly detect fearful faces exhibits high variability across individuals. The present study aimed to investigate the relationship between behavioral detection ability and brain activity, using both event-related potential (ERP and event-related oscillation (ERO measurements. Faces with fearful or neutral facial expressions were presented for 17 ms or 200 ms in a backward masking paradigm. Forty-two participants were required to discriminate facial expressions of the masked faces. The behavioral sensitivity index d' showed that the detection ability to rapidly presented and masked fearful faces varied across participants. The ANOVA analyses showed that the facial expression, hemisphere, and presentation duration affected the grand-mean ERP (N1, P1, and N170 and ERO (below 20 Hz and lasted from 100 ms to 250 ms post-stimulus, mainly in theta band brain activity. More importantly, the overall detection ability of 42 subjects was significantly correlated with the emotion effect (i.e., fearful vs. neutral on ERP (r = 0.403 and ERO (r = 0.552 measurements. A higher d' value was corresponding to a larger size of the emotional effect (i.e., fearful--neutral of N170 amplitude and a larger size of the emotional effect of the specific ERO spectral power at the right hemisphere. The present results suggested a close link between behavioral detection ability and the N170 amplitude as well as the ERO spectral power below 20 Hz in individuals. The emotional effect size between fearful and neutral faces in brain activity may reflect the level of conscious awareness of fearful faces.

  4. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    Science.gov (United States)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  5. Mask manufacturing improvement through capability definition and bottleneck line management

    Science.gov (United States)

    Strott, Al

    1994-02-01

    In 1989, Intel's internal mask operation limited itself to research and development activities and re-inspection and pellicle application of externally manufactured masks. Recognizing the rising capital cost of mask manufacturing at the leading edge, Intel's Mask Operation management decided to offset some of these costs by manufacturing more masks internally. This was the beginning of the challenge they set to manufacture at least 50% of Intel's mask volume internally, at world class performance levels. The first step in responding to this challenge was the completion of a comprehensive operation capability analysis. A series of bottleneck improvements by focus teams resulted in an average cycle time improvement to less than five days on all product and less than two days on critical products.

  6. Random mask optimization for fast neutron coded aperture imaging

    Energy Technology Data Exchange (ETDEWEB)

    McMillan, Kyle [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Univ. of California, Los Angeles, CA (United States); Marleau, Peter [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Brubaker, Erik [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-05-01

    In coded aperture imaging, one of the most important factors determining the quality of reconstructed images is the choice of mask/aperture pattern. In many applications, uniformly redundant arrays (URAs) are widely accepted as the optimal mask pattern. Under ideal conditions, thin and highly opaque masks, URA patterns are mathematically constructed to provide artifact-free reconstruction however, the number of URAs for a chosen number of mask elements is limited and when highly penetrating particles such as fast neutrons and high-energy gamma-rays are being imaged, the optimum is seldom achieved. In this case more robust mask patterns that provide better reconstructed image quality may exist. Through the use of heuristic optimization methods and maximum likelihood expectation maximization (MLEM) image reconstruction, we show that for both point and extended neutron sources a random mask pattern can be optimized to provide better image quality than that of a URA.

  7. Joint optimization of source, mask, and pupil in optical lithography

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y.

    2014-03-01

    Mask topography effects need to be taken into consideration for more advanced resolution enhancement techniques in optical lithography. However, rigorous 3D mask model achieves high accuracy at a large computational cost. This work develops a combined source, mask and pupil optimization (SMPO) approach by taking advantage of the fact that pupil phase manipulation is capable of partially compensating for mask topography effects. We first design the pupil wavefront function by incorporating primary and secondary spherical aberration through the coefficients of the Zernike polynomials, and achieve optimal source-mask pair under the condition of aberrated pupil. Evaluations against conventional source mask optimization (SMO) without incorporating pupil aberrations show that SMPO provides improved performance in terms of pattern fidelity and process window sizes.

  8. Effects of mask imperfections on InP etching profiles

    International Nuclear Information System (INIS)

    Huo, D.T.C.; Yan, M.F.; Wynn, J.D.; Wilt, D.P.

    1990-01-01

    The authors have demonstrated that the quality of etch masks has a significant effect on the InP etching profiles. In particular, the authors have shown that mask imperfections can cause defective etching profiles, such as vertical sidewalls and extra mask undercutting in InP. The authors also discovered that the geometry of these defective profiles is determined by the orientation of the substrate relative to the direction of the mask imperfections. Along a left-angle 110 right-angle line mask defect, the downward etching process changes the left-angle 110 right-angle v-grooves to vertical sidewalls without extra undercutting. For v-grooves aligned along the left-angle 110 right-angle direction, defects on the mask give a significant extra undercutting without changing the etching profile

  9. Face identification with frequency domain matched filtering in mobile environments

    Science.gov (United States)

    Lee, Dong-Su; Woo, Yong-Hyun; Yeom, Seokwon; Kim, Shin-Hwan

    2012-06-01

    Face identification at a distance is very challenging since captured images are often degraded by blur and noise. Furthermore, the computational resources and memory are often limited in the mobile environments. Thus, it is very challenging to develop a real-time face identification system on the mobile device. This paper discusses face identification based on frequency domain matched filtering in the mobile environments. Face identification is performed by the linear or phase-only matched filter and sequential verification stages. The candidate window regions are decided by the major peaks of the linear or phase-only matched filtering outputs. The sequential stages comprise a skin-color test and an edge mask filtering test, which verify color and shape information of the candidate regions in order to remove false alarms. All algorithms are built on the mobile device using Android platform. The preliminary results show that face identification of East Asian people can be performed successfully in the mobile environments.

  10. Familiar face + novel face = familiar face? Representational bias in the perception of morphed faces in chimpanzees

    Directory of Open Access Journals (Sweden)

    Yoshi-Taka Matsuda

    2016-08-01

    Full Text Available Highly social animals possess a well-developed ability to distinguish the faces of familiar from novel conspecifics to induce distinct behaviors for maintaining society. However, the behaviors of animals when they encounter ambiguous faces of familiar yet novel conspecifics, e.g., strangers with faces resembling known individuals, have not been well characterised. Using a morphing technique and preferential-looking paradigm, we address this question via the chimpanzee’s facial–recognition abilities. We presented eight subjects with three types of stimuli: (1 familiar faces, (2 novel faces and (3 intermediate morphed faces that were 50% familiar and 50% novel faces of conspecifics. We found that chimpanzees spent more time looking at novel faces and scanned novel faces more extensively than familiar or intermediate faces. Interestingly, chimpanzees looked at intermediate faces in a manner similar to familiar faces with regards to the fixation duration, fixation count, and saccade length for facial scanning, even though the participant was encountering the intermediate faces for the first time. We excluded the possibility that subjects merely detected and avoided traces of morphing in the intermediate faces. These findings suggest a bias for a feeling-of-familiarity that chimpanzees perceive familiarity with an intermediate face by detecting traces of a known individual, as 50% alternation is sufficient to perceive familiarity.

  11. Characterizing the monaural and binaural processes underlying reflection masking

    DEFF Research Database (Denmark)

    Buchholz, Jörg

    2007-01-01

    for the two RMTs, it is shown that forward masking effects only have a significant effect on reflection masking for delays above 7–10 ms. Moreover, binaural mechanisms were revealed which deteriorate auditory detection of test reflections for delays below 7–10 ms and enhance detection for larger delays....... The monaural and binaural processes that may underlie reflection masking are discussed in terms of auditory-modelling concepts....

  12. Prevalence of Occupational Asthma and Respiratory Symptoms in Foundry Workers

    Directory of Open Access Journals (Sweden)

    Servet Kayhan

    2013-01-01

    Full Text Available This cross-sectional study was conducted in a foundry factory to assess the prevalence of respiratory symptoms and occupational asthma in foundry workers. Physical examination, spirometric evaluation, chest radiograph, and a questionnaire related to respiratory symptoms were performed. Monitoring of peak expiratory flow rates, spirometric reversibility test, and high-resolution computed tomographies were performed for the participants having respiratory symptoms and/or impaired respiratory function test. A total of 347 participants including 286 workers from production department and 61 subjects who worked in nonproduction departments were enrolled in this study. It is found that phlegm (n: 71, 20.46% and cough (n: 52, 14.98% were the most frequent symptoms. The other symptoms were breathlessness (n: 28, 8.06%, chest tightness (n: 14, 4.03%, and wheezing (n: 7, 2.01% . The prevalence of occupational asthma was found to be more frequent among the subjects who worked in the production department (n: 48, 16.78% than the other persons who worked in the nonproduction department (n: 3, 4.91% by chi-square test (P: 0.001. To prevent hazardous respiratory effects of the foundry production, an early diagnosis of occupational asthma is very important. Cessation of cigarette smoking and using of protective masks during the working time should be encouraged.

  13. Respiratory Syncytial Virus (RSV)

    Centers for Disease Control (CDC) Podcasts

    2013-02-04

    Respiratory Syncytial Virus, or RSV, causes cold-like symptoms but can be serious for infants and older adults. In this podcast, CDC’s Dr. Eileen Schneider discusses this common virus and offers tips to prevent its spread.  Created: 2/4/2013 by National Center for Immunization and Respiratory Diseases (NCIRD), Division of Viral Diseases (DVD).   Date Released: 2/13/2013.

  14. Obesity and respiratory diseases

    OpenAIRE

    Zammit, Christopher; Liddicoat, Helen; Moonsie, Ian; Makker, Himender

    2010-01-01

    Christopher Zammit, Helen Liddicoat, Ian Moonsie, Himender MakkerSleep and Ventilation Unit, Department of Respiratory Medicine, North Middlesex University Hospital, London, UKAbstract: The obesity epidemic is a global problem, which is set to increase over time. However, the effects of obesity on the respiratory system are often underappreciated. In this review, we will discuss the mechanical effects of obesity on lung physiology and the function of adipose tissue as an endocrine organ produ...

  15. Acute respiratory distress syndrome

    OpenAIRE

    Confalonieri, Marco; Salton, Francesco; Fabiano, Francesco

    2017-01-01

    Since its first description, the acute respiratory distress syndrome (ARDS) has been acknowledged to be a major clinical problem in respiratory medicine. From July 2015 to July 2016 almost 300 indexed articles were published on ARDS. This review summarises only eight of them as an arbitrary overview of clinical relevance: definition and epidemiology, risk factors, prevention and treatment. A strict application of definition criteria is crucial, but the diverse resource-setting scenarios foste...

  16. Respiratory Syncytial Virus Vaccines

    OpenAIRE

    Dudas, Robert A.; Karron, Ruth A.

    1998-01-01

    Respiratory syncytial virus (RSV) is the most important cause of viral lower respiratory tract illness (LRI) in infants and children worldwide and causes significant LRI in the elderly and in immunocompromised patients. The goal of RSV vaccination is to prevent serious RSV-associated LRI. There are several obstacles to the development of successful RSV vaccines, including the need to immunize very young infants, who may respond inadequately to vaccination; the existence of two antigenically d...

  17. Tachistoscopic illumination and masking of real scenes.

    Science.gov (United States)

    Chichka, David; Philbeck, John W; Gajewski, Daniel A

    2015-03-01

    Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and directional locations of objects in 2-D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues can be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This article describes the system and the timing characteristics of each component. We verified the system's ability to control exposure to time scales as low as a few milliseconds.

  18. The performances of standard and ResMed masks during bag-valve-mask ventilation.

    Science.gov (United States)

    Lee, Hyoung Youn; Jeung, Kyung Woon; Lee, Byung Kook; Lee, Seung Joon; Jung, Yong Hun; Lee, Geo Sung; Min, Yong Il; Heo, Tag

    2013-01-01

    A tight mask seal is frequently difficult to obtain and maintain during single-rescuer bag-valve-mask (BVM) ventilation. The ResMed mask (Bella Vista, NSW, Australia) is a continuous-positive-airway-pressure mask (CM) designed for noninvasive ventilation. In this study, we compared the ventilation performances of a standard mask (SM) and a ResMed CM using a simulation manikin in an out-of-hospital single-rescuer BVM ventilation scenario. Thirty emergency medical technicians (EMTs) performed two 2-minute attempts to ventilate a simulation manikin using BVM ventilation, alternatively, with the SM or the ResMed CM in a randomized order. Ventilation parameters including tidal volume and peak airway pressure were measured using computer analysis software connected to the simulation manikin. Successful volume delivery was defined as delivery of 440-540 mL of tidal volume in accord with present cardiopulmonary resuscitation guidelines. BVM ventilation using the ResMed CM produced higher mean (± standard deviation) tidal volumes (452 ± 50 mL vs. 394 ± 113 mL, p = 0.014) and had a higher proportion of successful volume deliveries (65.3% vs. 26.7%, p < 0.001) than that using the SM. Peak airway pressure was higher in BVM ventilation using the ResMed CM (p = 0.035). Stomach insufflation did not occur during either method. Twenty-nine of the participants (96.7%) preferred BVM ventilation using the ResMed CM. BVM ventilations using ResMed CM resulted in a significantly higher proportion of successful volume deliveries meeting the currently recommended range of tidal volume. Clinical studies are needed to determine the value of the ResMed CM for BVM ventilation.

  19. Respiratory fit testing for farmworkers in the Black Dirt region of Hudson Valley, New York.

    Science.gov (United States)

    Earle-Richardson, Giulia; Fiske, Todd; Wyckoff, Sherry; Shuford, James; May, John

    2014-01-01

    Respiratory protection in agriculture has lagged behind other industries. Migrant farmworkers often work in dusty environments yet do not receive appropriate, fitted respiratory protection. During May and June of 2013, researchers pilot-tested a respiratory protection program adapted to fit the unique needs of migrant and seasonal farmworkers. It was implemented in Spanish, with literacy support, at convenient times and locations. Additionally, staff was known to workers, and a farmworker medical center provided medical follow-up. Fifty-six farmworkers participated (68%; 82 invited). Of the participants, 88% were male; 20% reported using respiratory protection. One worker had been fit tested previously; 57% reported being exposed to pesticides. All but six farmworkers passed the medical clearance (91%). The mask most commonly fit to the American-born population was a good fit for only 41% of Latino farmworkers. The fact that two thirds of invited farmworkers participated in the clearance and over half completed mask fitting indicates that the modified protocol meets farmworker needs. A wide range of mask types should be made available for Latino farmworkers.

  20. Mechanical and thermal modeling of the SCALPEL mask

    International Nuclear Information System (INIS)

    Martin, C. J.; Semke, W. H.; Dicks, G. A.; Engelstad, R. L.; Lovell, E. G.; Liddle, J. A.; Novembre, A. E.

    1999-01-01

    Scattering with angular limitation projection electron-beam lithography (SCALPEL) is being developed by Lucent Technologies for sub-130 nm lithography. The mask fabrication and exposure processes produce mask distortions that result in pattern placement errors. In order to understand these distortions, and determine how to reduce them to levels consistent with the error budget, structural and heat transfer finite element models have been generated to simulate the mechanical and thermal response of the mask. In addition, sensitivity studies of the distortions due to key design parameters that may be used to refine the SCALPEL mask configuration have been conducted. (c) 1999 American Vacuum Society

  1. Communication masking in marine mammals: A review and research strategy.

    Science.gov (United States)

    Erbe, Christine; Reichmuth, Colleen; Cunningham, Kane; Lucke, Klaus; Dooling, Robert

    2016-02-15

    Underwater noise, whether of natural or anthropogenic origin, has the ability to interfere with the way in which marine mammals receive acoustic signals (i.e., for communication, social interaction, foraging, navigation, etc.). This phenomenon, termed auditory masking, has been well studied in humans and terrestrial vertebrates (in particular birds), but less so in marine mammals. Anthropogenic underwater noise seems to be increasing in parts of the world's oceans and concerns about associated bioacoustic effects, including masking, are growing. In this article, we review our understanding of masking in marine mammals, summarise data on marine mammal hearing as they relate to masking (including audiograms, critical ratios, critical bandwidths, and auditory integration times), discuss masking release processes of receivers (including comodulation masking release and spatial release from masking) and anti-masking strategies of signalers (e.g. Lombard effect), and set a research framework for improved assessment of potential masking in marine mammals. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Masking interrupts figure-ground signals in V1.

    Science.gov (United States)

    Lamme, Victor A F; Zipser, Karl; Spekreijse, Henk

    2002-10-01

    In a backward masking paradigm, a target stimulus is rapidly (figure-ground segregation can be recorded. Here, we recorded from awake macaque monkeys, engaged in a task where they had to detect figures from background in a pattern backward masking paradigm. We show that the V1 figure-ground signals are selectively and fully suppressed at target-mask intervals that psychophysically result in the target being invisible. Initial response transients, signalling the features that make up the scene, are not affected. As figure-ground modulations depend on feedback from extrastriate areas, these results suggest that masking selectively interrupts the recurrent interactions between V1 and higher visual areas.

  3. Estimation of the Ideal Binary Mask using Directional Systems

    DEFF Research Database (Denmark)

    Boldt, Jesper; Kjems, Ulrik; Pedersen, Michael Syskind

    2008-01-01

    The ideal binary mask is often seen as a goal for time-frequency masking algorithms trying to increase speech intelligibility, but the required availability of the unmixed signals makes it difficult to calculate the ideal binary mask in any real-life applications. In this paper we derive the theory...... and the requirements to enable calculations of the ideal binary mask using a directional system without the availability of the unmixed signals. The proposed method has a low complexity and is verified using computer simulation in both ideal and non-ideal setups showing promising results....

  4. Improvement of radiographs by means of optical masks

    International Nuclear Information System (INIS)

    Shishov, B.A.; Tereshenko, O.I.; Tyurin, E.I.

    1985-01-01

    High-gradient photographic material improves contrast and detectability of small details. Parts of the radiographs will however tend to be over- or underexposed. The recorded information can be improved by optical masks that modify the light in various parts of the image according to film sensitivity. For screen-film systems an immediate correction of the image by inserted masks results in a better recording of details while the well known detail filtering process improves only the visual detectability of the already recorded information. A special cassette for the generation of masks and a method for the calculation of correction factors for various screen combinations and masks types are described. (author)

  5. Simulation-based MDP verification for leading-edge masks

    Science.gov (United States)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification

  6. Overlay improvement by exposure map based mask registration optimization

    Science.gov (United States)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density

  7. Editing faces in videos

    OpenAIRE

    Amberg, Brian

    2011-01-01

    Editing faces in movies is of interest in the special effects industry. We aim at producing effects such as the addition of accessories interacting correctly with the face or replacing the face of a stuntman with the face of the main actor. The system introduced in this thesis is based on a 3D generative face model. Using a 3D model makes it possible to edit the face in the semantic space of pose, expression, and identity instead of pixel space, and due to its 3D nature allows...

  8. Managing respiratory problems in athletes.

    Science.gov (United States)

    Hull, James H; Ansley, Les; Robson-Ansley, Paula; Parsons, Jonathan P

    2012-08-01

    Respiratory problems are common in athletes of all abilities and can significantly impact upon their health and performance. In this article, we provide an overview of respiratory physiology in athletes. We also discuss the assessment and management of common clinical respiratory conditions as they pertain to athletes, including airways disease, respiratory tract infection and pneumothorax. We focus on providing a pragmatic approach and highlight important caveats for the physician treating respiratory conditions in this highly specific population.

  9. Mask face: bilateral simultaneous facial palsy in an 11-year-old boy.

    Science.gov (United States)

    Güngör, Serdal; Güngör Raif, Sabiha; Arslan, Müjgan

    2013-04-01

    Bilateral facial paralysis is an uncommon clinical entity especially in the pediatric age group and occurs frequently as a manifestation of systemic disease. The most important causes are trauma, infectious diseases, neurological diseases, metabolic, neoplastic, autoimmune diseases and idiopathic disease (Bell's palsy). We report a case of an 11-year-old boy presenting with bilateral simultaneous peripheral facial paralysis. All possible infectious causes were excluded and the patient was diagnosed as having Bell's palsy (idiopathic). The most important approach in these cases is to rule out a life-threatening disease. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  10. Management of skeletal Class III malocclusion with face mask therapy and comprehensive orthodontic treatment.

    Science.gov (United States)

    Muthukumar, Kirthika; Vijaykumar, N M; Sainath, M C

    2016-01-01

    Orthopedic correction of skeletal Class III malocclusion in a growing patient is crucial as it can circumvent future surgical procedures. Further, as surgery is done only at a later stage, early treatment helps to avoid the detrimental effects produced by the facial disfigurement on the patient's social life. This case report describes the treatment of a child aged 9 years 6 months who had a skeletal Class III malocclusion. The treatment plan involved the use of a reverse pull headgear (facemask) and multibracket appliance therapy resulting in successful correction of the malocclusion. The treatment results were highly satisfactory resulting in improved facial esthetics, a skeletal Class I with a Dental Class I molar and canine relationship, an ideal overjet and overbite. Thus, dentoalveolar camouflage, if done in properly selected cases, alleviates the need for surgical intervention. The patient is being monitored until the end of growth to ensure the stability of treatment results.

  11. Dazzles, decoys, and deities : the Janus face of anti-facial recognition masks

    NARCIS (Netherlands)

    de Vries, P.B.

    2017-01-01

    Over the past few years a growing number of artists have critiqued the ubiquity of identity recognition technologies. Specifically, the use of these technologies by state security programs, tech-giants and multinational corporations has met with opposition and controversy. A popular form of

  12. Management of skeletal Class III malocclusion with face mask therapy and comprehensive orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Kirthika Muthukumar

    2016-01-01

    Full Text Available Orthopedic correction of skeletal Class III malocclusion in a growing patient is crucial as it can circumvent future surgical procedures. Further, as surgery is done only at a later stage, early treatment helps to avoid the detrimental effects produced by the facial disfigurement on the patient's social life. This case report describes the treatment of a child aged 9 years 6 months who had a skeletal Class III malocclusion. The treatment plan involved the use of a reverse pull headgear (facemask and multibracket appliance therapy resulting in successful correction of the malocclusion. The treatment results were highly satisfactory resulting in improved facial esthetics, a skeletal Class I with a Dental Class I molar and canine relationship, an ideal overjet and overbite. Thus, dentoalveolar camouflage, if done in properly selected cases, alleviates the need for surgical intervention. The patient is being monitored until the end of growth to ensure the stability of treatment results.

  13. CONTEMPORARY PROBLEMS OF EVALUATION OF HYPERTENSION TREATMENT EFFICACY: MASKED HYPERTENSION AND WHITE COAT HYPERTENSION

    Directory of Open Access Journals (Sweden)

    V. M. Gorbunov

    2016-01-01

    Full Text Available The implementation of contemporary ambulatory methods of BP level evaluation in clinical practice improved diagnostics of arterial hypertension (HT, but at the same time faced with specific problems. White coat HT (WCHT and masked HT are characterized by inconsistency between ambulatory and clinical BP levels. Studying of these conditions in patients receiving antihypertensive therapy is important. The WCHT during treatment (target ambulatory BP levels and no control of clinical BP is observed in 10-20% of patients. The cardiovascular risk in these patients does not differ significantly from the risk in patients with controlled BP. Masked HT (target levels of clinical BP and no control of ambulatory BP is observed in 5,4-23% of patients. The cardiovascular risk in patients with masked HT is 2,5-3,0 times more than that in patients with controlled HT and comparable with risk in patients with ineffective antihypertensive therapy. Thus, clinical measurements can give inexact data about true BP level in one third of treated hypertensive patients. Therefore the evaluation of cardiovascular risk and correct usage of ambulatory BP measurement is important for choice of therapy tactics in patients with HT. 

  14. CONTEMPORARY PROBLEMS OF EVALUATION OF HYPERTENSION TREATMENT EFFICACY: MASKED HYPERTENSION AND WHITE COAT HYPERTENSION

    Directory of Open Access Journals (Sweden)

    V. M. Gorbunov

    2009-01-01

    Full Text Available The implementation of contemporary ambulatory methods of BP level evaluation in clinical practice improved diagnostics of arterial hypertension (HT, but at the same time faced with specific problems. White coat HT (WCHT and masked HT are characterized by inconsistency between ambulatory and clinical BP levels. Studying of these conditions in patients receiving antihypertensive therapy is important. The WCHT during treatment (target ambulatory BP levels and no control of clinical BP is observed in 10-20% of patients. The cardiovascular risk in these patients does not differ significantly from the risk in patients with controlled BP. Masked HT (target levels of clinical BP and no control of ambulatory BP is observed in 5,4-23% of patients. The cardiovascular risk in patients with masked HT is 2,5-3,0 times more than that in patients with controlled HT and comparable with risk in patients with ineffective antihypertensive therapy. Thus, clinical measurements can give inexact data about true BP level in one third of treated hypertensive patients. Therefore the evaluation of cardiovascular risk and correct usage of ambulatory BP measurement is important for choice of therapy tactics in patients with HT. 

  15. Actinic inspection of multilayer defects on EUV masks

    International Nuclear Information System (INIS)

    Barty, A; Liu, Y; Gullikson, E; Taylor, J S; Wood, O

    2005-01-01

    The production of defect-free mask blanks, and the development of techniques for inspecting and qualifying EUV mask blanks, remains a key challenge for EUV lithography. In order to ensure a reliable supply of defect-free mask blanks, it is necessary to develop techniques to reliably and accurately detect defects on un-patterned mask blanks. These inspection tools must be able to accurately detect all critical defects whilst simultaneously having the minimum possible false-positive detection rate. There continues to be improvement in high-speed non-actinic mask blank inspection tools, and it is anticipated that these tools can and will be used by industry to qualify EUV mask blanks. However, the outstanding question remains one of validating that non-actinic inspection techniques are capable of detecting all printable EUV defects. To qualify the performance of non-actinic inspection tools, a unique dual-mode EUV mask inspection system has been installed at the Advanced Light Source (ALS) synchrotron at Lawrence Berkeley National Laboratory. In high-speed inspection mode, whole mask blanks are scanned for defects using 13.5-nm wavelength light to identify and map all locations on the mask that scatter a significant amount of EUV light. In imaging, or defect review mode, a zone plate is placed in the reflected beam path to image a region of interest onto a CCD detector with an effective resolution on the mask of 100-nm or better. Combining the capabilities of the two inspection tools into one system provides the unique capability to determine the coordinates of native defects that can be used to compare actinic defect inspection with visible light defect inspection tools under commercial development, and to provide data for comparing scattering models for EUV mask defects

  16. Series 'Facing Radiation'. 2 Facing radiation is facing residents

    International Nuclear Information System (INIS)

    Hanzawa, Takahiro

    2013-01-01

    The series is to report how general people, who are not at all radiological experts, have faced and understood the problems and tasks of radiation given by the Fukushima Daiichi Nuclear Power Plant Accident (Mar. 2011). The section 2 is reported by an officer of Date City, which localizes at 60 km northern west of the Plant, borders on Iitate Village of Fukushima prefecture, and is indicated as the important area of contamination search (IACS), which the reporter has been conducted for as responsible personnel. In July 2011, the ambient dose was as high as 3.0-3.5 mc-Sv/h and the tentative storage place of contaminated materials was decided by own initiative of residents of a small community, from which the real decontamination started in the City. The target dose after decontamination was defined to be 1.0 mc-Sv/h: however, 28/32 IACS municipalities in the prefecture had not defined the target although they had worked for 2 years after the Accident for their areas exceeding the standard 0.23 mc-Sv/h. At the moment of decontamination of the reporter's own house, he noticed that resident's concerns had directed toward its work itself, not toward the target dose, and wondered if these figures had obstructed to correctly face the radiation. At present that about 2.5 years have passed since the Accident, all of Date citizens have personal accumulated glass dosimeters for seeing the effective external dose and it seems that their dose will not exceed 1 mSv/y if the ambient dose estimated is 0.3-5 mc-Sv/h. Media run to popularity not to face radiation, experts tend to hesitate to face media and residents, and radiation dose will be hardly reduced to zero, despite that correct understanding of radiation is a shorter way for residents' own ease: facing radiation is facing residents. (T.T.)

  17. Face Detection and Recognition

    National Research Council Canada - National Science Library

    Jain, Anil K

    2004-01-01

    .... Specifically, the report addresses the problem of detecting faces in color images in the presence of various lighting conditions and complex backgrounds as well as recognizing faces under variations...

  18. Measuring External Face Appearance for Face Classification

    OpenAIRE

    Masip, David; Lapedriza, Agata; Vitria, Jordi

    2007-01-01

    In this chapter we introduce the importance of the external features in face classification problems, and propose a methodology to extract the external features obtaining an aligned feature set. The extracted features can be used as input to any standard pattern recognition classifier, as the classic feature extraction approaches dealing with internal face regions in the literature. The resulting scheme follows a top-down segmentation approach to deal with the diversity inherent to the extern...

  19. Coherent diffractive imaging using randomly coded masks

    Energy Technology Data Exchange (ETDEWEB)

    Seaberg, Matthew H., E-mail: seaberg@slac.stanford.edu [CNRS and D.I., UMR 8548, École Normale Supérieure, 45 Rue d' Ulm, 75005 Paris (France); Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); D' Aspremont, Alexandre [CNRS and D.I., UMR 8548, École Normale Supérieure, 45 Rue d' Ulm, 75005 Paris (France); Turner, Joshua J. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States)

    2015-12-07

    We experimentally demonstrate an extension to coherent diffractive imaging that encodes additional information through the use of a series of randomly coded masks, removing the need for typical object-domain constraints while guaranteeing a unique solution to the phase retrieval problem. Phase retrieval is performed using a numerical convex relaxation routine known as “PhaseCut,” an iterative algorithm known for its stability and for its ability to find the global solution, which can be found efficiently and which is robust to noise. The experiment is performed using a laser diode at 532.2 nm, enabling rapid prototyping for future X-ray synchrotron and even free electron laser experiments.

  20. Masking properties of ceramics for veneer restorations.

    Science.gov (United States)

    Skyllouriotis, Andreas L; Yamamoto, Hideo L; Nathanson, Dan

    2017-10-01

    The translucency and opacity of ceramics play a significant role in emulating the natural color of teeth, but studies of the masking properties and limitations of dental ceramics when used as monolayer restorations are lacking. The purpose of this in vitro study was to determine the translucency of 6 materials used for veneer restorations by assessing their translucency parameters (TPs), contrast ratios (CRs), and potential to mask dark tooth colors. Ten square- or disk-shaped specimens (0.5-mm thickness, shade A2) were fabricated from Vitablocks Mark II (VMII; Vita Zahnfabrik), IPS e.max CAD LT (EMXC LT; Ivoclar Vivadent AG), IPS e.max CAD HT (EMXC HT; Ivoclar Vivadent AG), IPS Empress CAD LT (EMP LT; Ivoclar Vivadent AG), IPS e.max Press LT (EMXP LT; Ivoclar Vivadent AG), and CZR (CZR; Kuraray Noritake Dental Inc). Their luminance (Y) values over black and over white tiles were measured, followed by their color (CIELab) over black tiles and white tiles and shaded A2 (control group), A3.5, A4, and B4 acrylic resin blocks. All measurements were performed using a spectrophotometer in 2 different areas on each specimen. Then CRs, TPs, and color differences (over shaded backgrounds) were determined. Data were subjected to 1-way and 2-way ANOVA (α=.05) for analysis. Mean CR values of EMXP LT were significantly higher than those of the other tested materials, whereas VMII and EMXC HT had the lowest values (Pmasking properties against the A4 background. The color differences of most tested ceramics were more acceptable when tested against the B4 background (ΔE*≤3.3). Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Prevalence and persistence of masked hypertension in treated hypertensive patients

    NARCIS (Netherlands)

    Verberk, Willem J.; Thien, Theo; Kroon, Abraham A.; Lenders, Jacques W. M.; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    2007-01-01

    Background: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  2. Prevalence and persistence of masked hypertension in treated hypertensive patients.

    NARCIS (Netherlands)

    Verberk, W.J.; Thien, Th.; Kroon, A.A.; Lenders, J.W.M.; Montfrans, G.A. van; Smit, A.J.; Leeuw, P.W. de

    2007-01-01

    BACKGROUND: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  3. Prevalence and persistence of masked hypertension in treated hypertensive patients

    NARCIS (Netherlands)

    Verberk, Willem J.; Thien, Theo; Kroon, Abraham A.; Lenders, Jacques W. M.; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    2007-01-01

    BACKGROUND: Masked hypertension (MH) is defined as a normal blood pressure in the physician's office and an elevated blood pressure when measured out-of-office. The cause of MH may be termed the masked hypertension effect (MHE), and is not restricted to blood-pressure (BP) values around the

  4. Self-masking: Listening during vocalization. Normal hearing.

    Science.gov (United States)

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  5. Failed tracheal intubation using a laryngoscope and intubating laryngeal mask.

    Science.gov (United States)

    Asai, T; Hirose, T; Shingu, K

    2000-04-01

    To report unexpected failed tracheal intubation using a laryngoscope and an intubating laryngeal mask, and difficult ventilation via a facemask, laryngeal mask and intubating laryngeal mask, in a patient with an unrecognized lingual tonsillar hypertrophy. A 63-yr-old woman, who had undergone clipping of an aneurysm seven weeks previously, was scheduled for ventriculo-peritoneal shunt. At the previous surgery, there had been no difficulty in ventilation or in tracheal intubation. Her trachea remained intubated nasally for 11 days after surgery. Preoperatively, her consciousness was impaired. There were no restrictions in head and neck movements or mouth opening. The thyromental distance was 7 cm. After induction of anesthesia, manual ventilation via a facemask with a Guedel airway was suboptimal and the chest expanded insufficiently. At laryngoscopy using a Macintosh or McCoy device, only the tip of the epiglottis, but not the glottis, could be seen, and tracheal intubation failed. There was a partial obstruction during manual ventilation through either the intubating laryngeal mask or conventional laryngeal mask; intubation through each device failed. Digital examination of the pharynx, after removal of the laryngeal mask, indicated a mass occupying the vallecula. Lingual tonsillar hypertrophy (1 x 1 x 2 cm) was found to be the cause of the failure. Awake fibrescope-aided tracheal intubation was accomplished. Unexpected lingual tonsillar hypertrophy can cause both ventilation and tracheal intubation difficult, and neither the laryngeal mask nor intubating laryngeal mask may be helpful in the circumstances.

  6. Ni-Al Alloys as Alternative EUV Mask Absorber

    Directory of Open Access Journals (Sweden)

    Vu Luong

    2018-03-01

    Full Text Available Extreme ultraviolet (EUV lithography is being industrialized as the next candidate printing technique for high-volume manufacturing of scaled down integrated circuits. At mask level, the combination of EUV light at oblique incidence, absorber thickness, and non-uniform mirror reflectance through incidence angle, creates photomask-induced imaging aberrations, known as mask 3D (M3D effects. A possible mitigation for the M3D effects in the EUV binary intensity mask (BIM, is to use mask absorber materials with high extinction coefficient κ and refractive coefficient n close to unity. We propose nickel aluminide alloys as a candidate BIM absorber material, and characterize them versus a set of specifications that a novel EUV mask absorber must meet. The nickel aluminide samples have reduced crystallinity as compared to metallic nickel, and form a passivating surface oxide layer in neutral solutions. Composition and density profile are investigated to estimate the optical constants, which are then validated with EUV reflectometry. An oxidation-induced Al L2 absorption edge shift is observed, which significantly impacts the value of n at 13.5 nm wavelength and moves it closer to unity. The measured optical constants are incorporated in an accurate mask model for rigorous simulations. The M3D imaging impact of the nickel aluminide alloy mask absorbers, which predict significant M3D reduction in comparison to reference absorber materials. In this paper, we present an extensive experimental methodology flow to evaluate candidate mask absorber materials.

  7. Energy enhancer for mask based laser materials processing

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1996-01-01

    A device capable of drastically improving the energy efficiency of present mask based laser materials processing systems is presented. Good accordance between experiments and simulations for a TEA-CO2 laser system designed for laser marking has been demonstrated. The energy efficiency may...... be improved with a factor of 2 - 4 for typical mask transmittances between 10 - 40%....

  8. My Other Half Manifested in Mask-Making

    Science.gov (United States)

    Abel, Xanthippi

    2010-01-01

    Every fall season, each grade level of Rowland Hall St. Mark's Lower School in Salt Lake City, Utah, completes a mask-making project to be featured in a schoolwide parade. This sparked an opportunity to incorporate the fourth-grade unit of realistic and observational drawing with mask making. In this article, the author describes how her students…

  9. GABAA agonist reduces visual awareness : a masking-EEG experiment

    NARCIS (Netherlands)

    van Loon, Anouk M; Scholte, H Steven; van Gaal, Simon; van der Hoort, Björn J J; Lamme, Victor A F

    Consciousness can be manipulated in many ways. Here, we seek to understand whether two such ways, visual masking and pharmacological intervention, share a common pathway in manipulating visual consciousness. We recorded EEG from human participants who performed a backward-masking task in which they

  10. Reusable High Aspect Ratio 3-D Nickel Shadow Mask

    Science.gov (United States)

    Shandhi, M.M.H.; Leber, M.; Hogan, A.; Warren, D.J.; Bhandari, R.; Negi, S.

    2017-01-01

    Shadow Mask technology has been used over the years for resistless patterning and to pattern on unconventional surfaces, fragile substrate and biomaterial. In this work, we are presenting a novel method to fabricate high aspect ratio (15:1) three-dimensional (3D) Nickel (Ni) shadow mask with vertical pattern length and width of 1.2 mm and 40 μm respectively. The Ni shadow mask is 1.5 mm tall and 100 μm wide at the base. The aspect ratio of the shadow mask is 15. Ni shadow mask is mechanically robust and hence easy to handle. It is also reusable and used to pattern the sidewalls of unconventional and complex 3D geometries such as microneedles or neural electrodes (such as the Utah array). The standard Utah array has 100 active sites at the tip of the shaft. Using the proposed high aspect ratio Ni shadow mask, the Utah array can accommodate 300 active sites, 200 of which will be along and around the shaft. The robust Ni shadow mask is fabricated using laser patterning and electroplating techniques. The use of Ni 3D shadow mask will lower the fabrication cost, complexity and time for patterning out-of-plane structures. PMID:29056835

  11. Mask Materials and Designs for Extreme Ultra Violet Lithography

    Science.gov (United States)

    Kim, Jung Sik; Ahn, Jinho

    2018-03-01

    Extreme ultra violet lithography (EUVL) is no longer a future technology but is going to be inserted into mass production of semiconductor devices of 7 nm technology node in 2018. EUVL is an extension of optical lithography using extremely short wavelength (13.5 nm). This short wavelength requires major modifications in the optical systems due to the very strong absorption of EUV light by materials. Refractive optics can no longer be used, and reflective optics is the only solution to transfer image from mask to wafer. This is why we need the multilayer (ML) mirror-based mask as well as an oblique incident angle of light. This paper discusses the principal theory on the EUV mask design and its component materials including ML reflector and EUV absorber. Mask shadowing effect (or mask 3D effect) is explained and its technical solutions like phase shift mask is reviewed. Even though not all the technical issues on EUV mask are handled in this review paper, you will be able to understand the principles determining the performance of EUV masks.

  12. Masked hypertension: evidence of the need to treat

    NARCIS (Netherlands)

    Ogedegbe, Gbenga; Agyemang, Charles; Ravenell, Joseph E.

    2010-01-01

    The diagnosis of masked hypertension has been made easier with the widespread availability of home blood pressure monitoring devices with levels of accuracy comparable to ambulatory blood pressure monitoring. The negative impact of masked hypertension on cardiovascular morbidity and mortality is

  13. Pleasant and unpleasant odour-face combinations influence face and odour perception: An event-related potential study.

    Science.gov (United States)

    Cook, Stephanie; Kokmotou, Katerina; Soto, Vicente; Fallon, Nicholas; Tyson-Carr, John; Thomas, Anna; Giesbrecht, Timo; Field, Matt; Stancak, Andrej

    2017-08-30

    Odours alter evaluations of concurrent visual stimuli. However, neural mechanisms underlying the effects of congruent and incongruent odours on facial expression perception are not clear. Moreover, the influence of emotional faces on odour perception is not established. We investigated the effects of one pleasant and one unpleasant odour paired with happy and disgusted faces, on subjective ratings and ERP responses to faces. Participants rated the pleasantness of happy and disgusted faces that appeared during 3s pleasant or unpleasant odour pulses, or without odour. Odour pleasantness and intensity ratings were recorded in each trial. EEG was recorded continuously using a 128-channel system. Happy and disgusted faces paired with pleasant and unpleasant odour were rated as more or less pleasant, respectively, compared to the same faces presented in the other odour conditions. Odours were rated as more pleasant when paired with happy faces, and unpleasant odour was rated more intense when paired with disgusted faces. Unpleasant odour paired with disgusted faces also decreased inspiration. Odour-face interactions were evident in the N200 and N400 components. Our results reveal bi-directional effects of odours and faces, and suggest that odour-face interactions may be represented in ERP components. Pairings of unpleasant odour and disgusted faces resulted in stronger hedonic ratings, ERP changes, increased odour intensity ratings and respiratory adjustment. This finding likely represents heightened adaptive responses to multimodal unpleasant stimuli, prompting appropriate behaviour in the presence of danger. Copyright © 2017. Published by Elsevier B.V.

  14. New Y2K problem for mask making (or, Surviving mask data problems after 2000)

    Science.gov (United States)

    Sturgeon, Roger

    1999-08-01

    The Y2K problem has analogies in the mask-making world. With the Y2K problem where a date field has just two bytes for the year, there are some cases of mask-making data in which the file size cannot exceed 2 gigabytes. Where a two-digit date field can only unambiguously use a limited range of values (00 to 99), design coordinates can only cover a range of about 4 billion values, which is getting a little uncomfortable for all of the new applications. In retrospect, with a degree of foresight and planning the Y2K date problem could have been easily solved if new encodings had been allowed in the two- digit field. Likewise, in the mask-making industry we currently have the opportunity to achieve far superior data compression if we allow some new forms of data encoding in our data. But this will require universal agreement. The correct way to look at the Y2K problem is that some information was left out of the data stream due to common understandings that made the additional information superfluous. But as the year 2000 approaches, it has become widely recognized that missing data needs to be stated explicitly, and any ambiguities in the representation of the data will need to be eliminated with precise specifications. In a similar way, old mask data generation methods have had numerous flaws that we have been able to ignore for a long time. But now is the time to fix theses flaws and provide extended capabilities. What is not yet clear is if the old data generation methods can be modified to meet these developing needs. Unilateral action is not likely to lead to much progress, so some united effort is required by all interested parties if success is to be achieved in the brief time that remains.

  15. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  16. MODELING SPECTRAL AND TEMPORAL MASKING IN THE HUMAN AUDITORY SYSTEM

    DEFF Research Database (Denmark)

    Dau, Torsten; Jepsen, Morten Løve; Ewert, Stephan D.

    2007-01-01

    An auditory signal processing model is presented that simulates psychoacoustical data from a large variety of experimental conditions related to spectral and temporal masking. The model is based on the modulation filterbank model by Dau et al. [J. Acoust. Soc. Am. 102, 2892-2905 (1997)] but inclu......An auditory signal processing model is presented that simulates psychoacoustical data from a large variety of experimental conditions related to spectral and temporal masking. The model is based on the modulation filterbank model by Dau et al. [J. Acoust. Soc. Am. 102, 2892-2905 (1997...... was tested in conditions of tone-in-noise masking, intensity discrimination, spectral masking with tones and narrowband noises, forward masking with (on- and off-frequency) noise- and pure-tone maskers, and amplitude modulation detection using different noise carrier bandwidths. One of the key properties...

  17. Respiratory manifestations of hypothyroidism

    DEFF Research Database (Denmark)

    Sorensen, Jesper Roed; Winther, Kristian Hillert; Bonnema, Steen Joop

    2016-01-01

    BACKGROUND: Hypothyroidism has been associated with increased pulmonary morbidity and overall mortality. We conducted a systematic review to identify the prevalence and underlying mechanisms of respiratory problems among patients with thyroid insufficiency. METHODS: PubMed and EMBASE databases were...... searched for relevant literature from January 1950 through January 2015 with study eligibility criteria: English-language publications; Adult subclinical or overt hypothyroid patients; Intervention, observational or retrospective studies; and respiratory manifestations. We followed the PRISMA statement...... and used the Cochrane's risk of bias tool. RESULTS: A total of 1699 papers were screened by two independent authors for relevant titles. Of 109 relevant abstracts, 28 papers underwent full text analyses, of which 22 were included in the review. We identified possible mechanisms explaining respiratory...

  18. New method of 2-dimensional metrology using mask contouring

    Science.gov (United States)

    Matsuoka, Ryoichi; Yamagata, Yoshikazu; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2008-10-01

    We have developed a new method of accurately profiling and measuring of a mask shape by utilizing a Mask CD-SEM. The method is intended to realize high accuracy, stability and reproducibility of the Mask CD-SEM adopting an edge detection algorithm as the key technology used in CD-SEM for high accuracy CD measurement. In comparison with a conventional image processing method for contour profiling, this edge detection method is possible to create the profiles with much higher accuracy which is comparable with CD-SEM for semiconductor device CD measurement. This method realizes two-dimensional metrology for refined pattern that had been difficult to measure conventionally by utilizing high precision contour profile. In this report, we will introduce the algorithm in general, the experimental results and the application in practice. As shrinkage of design rule for semiconductor device has further advanced, an aggressive OPC (Optical Proximity Correction) is indispensable in RET (Resolution Enhancement Technology). From the view point of DFM (Design for Manufacturability), a dramatic increase of data processing cost for advanced MDP (Mask Data Preparation) for instance and surge of mask making cost have become a big concern to the device manufacturers. This is to say, demands for quality is becoming strenuous because of enormous quantity of data growth with increasing of refined pattern on photo mask manufacture. In the result, massive amount of simulated error occurs on mask inspection that causes lengthening of mask production and inspection period, cost increasing, and long delivery time. In a sense, it is a trade-off between the high accuracy RET and the mask production cost, while it gives a significant impact on the semiconductor market centered around the mask business. To cope with the problem, we propose the best method of a DFM solution using two-dimensional metrology for refined pattern.

  19. Bacterial aetiology in lower respiratory tract infections : Relevance in outpatients

    NARCIS (Netherlands)

    Teepe, J.

    2017-01-01

    Lower respiratory tract infection (LRTI) is one of the leading reasons for consulting in primary care. Today, a general practitioner faces the challenge of distinguishing between patients with a mild self-limiting disease to whom antibiotics would do more harm than good and those who would benefit

  20. Face time: educating face transplant candidates.

    Science.gov (United States)

    Lamparello, Brooke M; Bueno, Ericka M; Diaz-Siso, Jesus Rodrigo; Sisk, Geoffroy C; Pomahac, Bohdan

    2013-01-01

    Face transplantation is the innovative application of microsurgery and immunology to restore appearance and function to those with severe facial disfigurements. Our group aims to establish a multidisciplinary education program that can facilitate informed consent and build a strong knowledge base in patients to enhance adherence to medication regimes, recovery, and quality of life. We analyzed handbooks from our institution's solid organ transplant programs to identify topics applicable to face transplant patients. The team identified unique features of face transplantation that warrant comprehensive patient education. We created a 181-page handbook to provide subjects interested in pursuing transplantation with a written source of information on the process and team members and to address concerns they may have. While the handbook covers a wide range of topics, it is easy to understand and visually appealing. Face transplantation has many unique aspects that must be relayed to the patients pursuing this novel therapy. Since candidates lack third-party support groups and programs, the transplant team must provide an extensive educational component to enhance this complex process. As face transplantation continues to develop, programs must create sound education programs that address patients' needs and concerns to facilitate optimal care.

  1. Sugammadex use in difficult intubation due to ankylosing spondylitis and severe restrictive respiratory disease

    Directory of Open Access Journals (Sweden)

    Yakup Tomak

    2012-09-01

    Full Text Available We describe anesthesia management of a 50-year-old man scheduled for thoracic spinal reconstruction, presenting with severe restrictive respiratory disease and difficult airway due to ankylosing spondilitis. The patient was unable to extend his head, had difficulty in breathing and sleeping in supine position due to thoracal deformities. The patient was intubated using intubating laryngeal mask airway to overcome the difficulties of limited mouth opening and head extension. He was extubated following administration of sugammadex to obtain optimal conditions in terms of respiratory muscle function and to prevent hypersecretion and bronchospasm. J Clin Exp Invest 2012; 3 (3: 398-400Key words: Restrictive lung disease, airway management, laryngeal masks, sugammadex, ankylosing spondylitis

  2. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials

    DEFF Research Database (Denmark)

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L.

    2013-01-01

    at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result......The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound...... in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners...

  3. Simulation based mask defect repair verification and disposition

    Science.gov (United States)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple

  4. 75 FR 4323 - Additional Quantitative Fit-testing Protocols for the Respiratory Protection Standard

    Science.gov (United States)

    2010-01-27

    ...-mask and full face piece respirators are normally considered two different types of air purifying... article published in a peer-reviewed industrial-hygiene journal describing the protocol and explaining how... article from an industrial- hygiene journal describing the accuracy and reliability of these proposed...

  5. Hypercapnic Respiratory Acidosis During An In-Flight Oxygen Assessment.

    Science.gov (United States)

    Spurling, Kristofer J; Moonsie, Ian K; Perks, Joseph L

    2016-02-01

    Patients with respiratory disease are at risk of excessive hypoxemia in the hypobaric commercial aircraft cabin environment, and the consensus is that this is easily corrected with supplementary oxygen. However, despite the risks of hypercapnia with increasing inspired oxygen in some patients being well established, this issue is not currently addressed in medical guidelines for air travel. A 76-yr-old woman with chronic type 2 respiratory failure underwent hypoxic challenge testing (HCT) to assess in-flight oxygen requirements. She is stable on home ventilation, and baseline arterial blood gases showed mild hypoxemia (Pao2 9.12 kPa), normal P(a)co(2) (5.64 kPa) and pH (7.36) with 98% S(p)O(2). HCT was performed delivering 15% FIo(2) via a mask, and the patient desaturated to respiratory acidosis (pH 7.25). The patient was advised against flying due to hypoxemia during HCT and the precipitous drop in pH on oxygen. It is possible to hyperoxygenate patients with type 2 respiratory failure in flight with the minimum level of supplementary oxygen available on many aircraft. In these cases P(a)co(2) and pH should be scrutinized during HCT before recommending in-flight oxygen. No current guidelines discuss the risk of hypercapnia from in-flight oxygen; it is therefore recommended that this be addressed in future revisions of medical air travel guidelines, should further research indicate it.

  6. The microbiota of the respiratory tract : Gatekeeper to respiratory health

    NARCIS (Netherlands)

    Man, Wing Ho; De Steenhuijsen Piters, Wouter A.A.; Bogaert, Debby

    2017-01-01

    The respiratory tract is a complex organ system that is responsible for the exchange of oxygen and carbon dioxide. The human respiratory tract spans from the nostrils to the lung alveoli and is inhabited by niche-specific communities of bacteria. The microbiota of the respiratory tract probably acts

  7. Adult respiratory distress syndrome

    International Nuclear Information System (INIS)

    Svendsen, J.; Jespersen, J.; Skjoedt, T.

    1986-01-01

    Our present-day knowledge concerning the clinico-chemical and radiological findings in adult respiratory distress syndrome are described. Three typical case histories have been selected to illustrate this condition; they were due to multiple trauma or sepsis. It is stressed that radiology is in a key position for making the diagnosis and for observing the course of the illness. (orig) [de

  8. European Respiratory Society statement

    DEFF Research Database (Denmark)

    Miravitlles, Marc; Dirksen, Asger; Ferrarotti, Ilaria

    2017-01-01

    lung disease. A large proportion of individuals affected remain undiagnosed and therefore without access to appropriate care and treatment.The most recent international statement on AATD was published by the American Thoracic Society and the European Respiratory Society in 2003. Since then there has...

  9. Respiratory Syncytial Virus (RSV)

    Centers for Disease Control (CDC) Podcasts

    Respiratory Syncytial Virus, or RSV, causes cold-like symptoms but can be serious for infants and older adults. In this podcast, CDC’s Dr. Eileen Schneider discusses this common virus and offers tips to prevent its spread.

  10. Respiratory problems in foals.

    Science.gov (United States)

    Beech, J

    1985-04-01

    Despite major advances in our knowledge and ability to treat respiratory diseases in neonatal foals, neonatal respiratory medicine is still in its infancy. It is hoped that this article may serve as a guideline for diagnosis and treatment. Specific antibiotic regimens and emergency procedures are covered in other articles in this symposium. Because management factors play a critical role in the pathogenesis of respiratory disease, education of clients as to their importance would help both prophylactically and therapeutically. The necessity of very careful monitoring of neonates, which is critical to early detection of disease, should be stressed. As respiratory diseases can be fulminant and rapidly fatal, it is imperative not to delay diagnosis and therapy. Thorough examination and implementation of appropriate diagnostic techniques, as well as prompt early referral to a more sophisticated facility when indicated, would prevent many deaths. Although sophisticated support systems are vital for survival of some of these foals, good basic intensive nursing care combined with selection of appropriate drug therapy very early in the course of the disease is all that many foals require and can significantly improve survival rates.

  11. Respiratory Symptoms in Firefighters

    NARCIS (Netherlands)

    Greven, Frans E.; Rooyackers, Jos M.; Kerstjens, Huib A. M.; Heederik, Dick J.

    Background The aim of the present study was to determine the prevalence and risk factors associated with respiratory symptoms in common firefighters in the Netherlands. Methods A total of 1,330 firefighters from the municipal fire brigades of three provinces of the Netherlands were included in the

  12. Textbook of respiratory medicine

    International Nuclear Information System (INIS)

    Murray, J.F.; Nadel, J.

    1987-01-01

    This book presents a clinical reference of respiratory medicine. It also details basic science aspects of pulmonary physiology and describes recently developed, sophisticated diagnostic tools and therapeutic methods. It also covers anatomy, physiology, pharmacology, and pathology; microbiologic, radiologic, nuclear medicine, and biopsy methods for diagnosis

  13. Airflow-Restricting Mask Reduces Acute Performance in Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Yuri L. Motoyama

    2016-09-01

    Full Text Available Background: The aim of this study was to compare the number of repetitions to volitional failure, the blood lactate concentration, and the perceived exertion to resistance training with and without an airflow-restricting mask. Methods: Eight participants participated in a randomized, counterbalanced, crossover study. Participants were assigned to an airflow-restricting mask group (MASK or a control group (CONT and completed five sets of chest presses and parallel squats until failure at 75% one-repetition-maximum test (1RM with 60 s of rest between sets. Ratings of perceived exertion (RPEs, blood lactate concentrations (Lac−, and total repetitions were taken after the training session. Results: MASK total repetitions were lower than those of the CONT, and (Lac− and MASK RPEs were higher than those of the CONT in both exercises. Conclusions: We conclude that an airflow-restricting mask in combination with resistance training increase perceptions of exertion and decrease muscular performance and lactate concentrations when compared to resistance training without this accessory. This evidence shows that the airflow-restricting mask may change the central nervous system and stop the exercise beforehand to prevent some biological damage.

  14. MASKED AREAS IN SHEAR PEAK STATISTICS: A FORWARD MODELING APPROACH

    International Nuclear Information System (INIS)

    Bard, D.; Kratochvil, J. M.; Dawson, W.

    2016-01-01

    The statistics of shear peaks have been shown to provide valuable cosmological information beyond the power spectrum, and will be an important constraint of models of cosmology in forthcoming astronomical surveys. Surveys include masked areas due to bright stars, bad pixels etc., which must be accounted for in producing constraints on cosmology from shear maps. We advocate a forward-modeling approach, where the impacts of masking and other survey artifacts are accounted for in the theoretical prediction of cosmological parameters, rather than correcting survey data to remove them. We use masks based on the Deep Lens Survey, and explore the impact of up to 37% of the survey area being masked on LSST and DES-scale surveys. By reconstructing maps of aperture mass the masking effect is smoothed out, resulting in up to 14% smaller statistical uncertainties compared to simply reducing the survey area by the masked area. We show that, even in the presence of large survey masks, the bias in cosmological parameter estimation produced in the forward-modeling process is ≈1%, dominated by bias caused by limited simulation volume. We also explore how this potential bias scales with survey area and evaluate how much small survey areas are impacted by the differences in cosmological structure in the data and simulated volumes, due to cosmic variance

  15. Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    Science.gov (United States)

    Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan

    2013-01-01

    Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

  16. ARDS (Acute Respiratory Distress Syndrome)

    Science.gov (United States)

    ... Also known as What Is ARDS, or acute respiratory distress syndrome, is a lung condition that leads ... treat ARDS. Other Names Acute lung injury Adult respiratory distress syndrome Increased-permeability pulmonary edema Noncardiac pulmonary ...

  17. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... of our study was to compare the resulting imaging quality by the use of a time-based respiratory gating system in two groups administered either adenosine or dipyridamole as the pharmacological stress agent. METHODS AND RESULTS: Forty-eight patients were randomized to adenosine or dipyridamole cardiac...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4...

  18. Middle East Respiratory Syndrome (MERS)

    Science.gov (United States)

    Middle East Respiratory Syndrome Coronavirus; MERS-CoV; Novel coronavirus; nCoV ... for Disease Control and Prevention website. Middle East Respiratory Syndrome (MERS): Frequently asked questions and answers. www. ...

  19. Acute respiratory infections at children

    OpenAIRE

    Delyagin, V.

    2009-01-01

    The common signs of virus respiratory diseases, role of pathological inclination to infections, value of immunodeficiency are presented at lecture. Features of most often meeting respiratory virus infections are given.

  20. Face-to-face versus remote and web 2.0 interventions for promoting physical activity.

    Science.gov (United States)

    Richards, Justin; Thorogood, Margaret; Hillsdon, Melvyn; Foster, Charles

    2013-09-30

    Face-to-face interventions for promoting physical activity (PA) are continuing to be popular as remote and web 2.0 approaches rapidly emerge, but we are unsure which approach is more effective at achieving long term sustained change. To compare the effectiveness of face-to-face versus remote and web 2.0 interventions for PA promotion in community dwelling adults (aged 16 years and above). We searched CENTRAL, MEDLINE, EMBASE, CINAHL, and some other databases (from earliest dates available to October 2012). Reference lists of relevant articles were checked. No language restrictions were applied. Randomised trials that compared face-to-face versus remote and web 2.0 PA interventions for community dwelling adults. We included studies if they compared an intervention that was principally delivered face-to-face to an intervention that had principally remote and web 2.0 methods. To assess behavioural change over time, the included studies had a minimum of 12 months follow-up from the start of the intervention to the final results. We excluded studies that had more than a 20% loss to follow-up if they did not apply an intention-to-treat analysis. At least two review authors independently assessed the quality of each study and extracted the data. Non-English language papers were reviewed with the assistance of an interpreter who was an epidemiologist. Study authors were contacted for additional information where necessary. Standardised mean differences (SMDs) and 95% confidence intervals (CIs) were calculated for continuous measures of cardio-respiratory fitness. One study recruiting 225 apparently healthy adults met the inclusion criteria. This study took place in a high-income country. From 27,299 hits, the full texts of 193 papers were retrieved for examination against the inclusion criteria. However, there was only one paper that met the inclusion criteria. This study reported the effect of a PA intervention on cardio-respiratory fitness. There were no reported data