WorldWideScience

Sample records for respective carrier arm

  1. Bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles as novel tumor targeting carriers

    International Nuclear Information System (INIS)

    Ding Hong; Yong, Ken-Tye; Roy, Indrajit; Hu Rui; Zhao Lingling; Law, Wing-Cheung; Ji Wei; Liu Liwei; Bergey, Earl J; Prasad, Paras N; Wu Fang; Zhao Weiwei

    2011-01-01

    In this study, we have developed a novel carrier, micelle-type bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles (NPs), for the detection and treatment of pancreatic cancer. These NPs contained 4-arm-PEG as corona, and PLGA as core, the particle surface was conjugated with cyclo(arginine-glycine-aspartate) (cRGD) as ligand for in vivo tumor targeting. The hydrodynamic size of the NPs was determined to be 150-180 nm and the critical micellar concentration (CMC) was estimated to be 10.5 mg l -1 . Our in vitro study shows that these NPs by themselves had negligible cytotoxicity to human pancreatic cancer (Panc-1) and human glioblastoma (U87) cell lines. Near infrared (NIR) microscopy and flow cytometry demonstrated that the cRGD conjugated PLGA-4-arm-PEG polymeric NPs were taken up more efficiently by U87MG glioma cells, over-expressing the α v β 3 integrin, when compared with the non-targeted NPs. Whole body imaging showed that the cRGD conjugated PLGA-4-arm-PEG branched polymeric NPs had the highest accumulation in the pancreatic tumor site of mice at 48 h post-injection. Physical, hematological, and pathological assays indicated low in vivo toxicity of this NP formulation. These studies on the ability of these bioconjugated PLGA-4-arm-PEG polymeric NPs suggest that the prepared polymeric NPs may serve as a promising platform for detection and targeted drug delivery for pancreatic cancer.

  2. Bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles as novel tumor targeting carriers

    Energy Technology Data Exchange (ETDEWEB)

    Ding Hong; Yong, Ken-Tye; Roy, Indrajit; Hu Rui; Zhao Lingling; Law, Wing-Cheung; Ji Wei; Liu Liwei; Bergey, Earl J; Prasad, Paras N [Department of Chemistry, Institute for Lasers, Photonics and Biophotonics, University at Buffalo, State University of New York, Buffalo, NY 14260 (United States); Wu Fang [Department of Pharmaceutical Sciences, University at Buffalo, State University of New York, Buffalo, NY 14260 (United States); Zhao Weiwei, E-mail: bergeye@buffalo.edu, E-mail: pnprasad@buffalo.edu [Department of Microbiology and Immunology, University at Buffalo, State University of New York, Buffalo, NY 14215 (United States)

    2011-04-22

    In this study, we have developed a novel carrier, micelle-type bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles (NPs), for the detection and treatment of pancreatic cancer. These NPs contained 4-arm-PEG as corona, and PLGA as core, the particle surface was conjugated with cyclo(arginine-glycine-aspartate) (cRGD) as ligand for in vivo tumor targeting. The hydrodynamic size of the NPs was determined to be 150-180 nm and the critical micellar concentration (CMC) was estimated to be 10.5 mg l{sup -1}. Our in vitro study shows that these NPs by themselves had negligible cytotoxicity to human pancreatic cancer (Panc-1) and human glioblastoma (U87) cell lines. Near infrared (NIR) microscopy and flow cytometry demonstrated that the cRGD conjugated PLGA-4-arm-PEG polymeric NPs were taken up more efficiently by U87MG glioma cells, over-expressing the {alpha}{sub v{beta}3} integrin, when compared with the non-targeted NPs. Whole body imaging showed that the cRGD conjugated PLGA-4-arm-PEG branched polymeric NPs had the highest accumulation in the pancreatic tumor site of mice at 48 h post-injection. Physical, hematological, and pathological assays indicated low in vivo toxicity of this NP formulation. These studies on the ability of these bioconjugated PLGA-4-arm-PEG polymeric NPs suggest that the prepared polymeric NPs may serve as a promising platform for detection and targeted drug delivery for pancreatic cancer.

  3. 14 CFR 382.95 - What are carriers' general obligations with respect to boarding and deplaning assistance?

    Science.gov (United States)

    2010-01-01

    ... respect to boarding and deplaning assistance? 382.95 Section 382.95 Aeronautics and Space OFFICE OF THE... BASIS OF DISABILITY IN AIR TRAVEL Boarding, Deplaning, and Connecting Assistance § 382.95 What are carriers' general obligations with respect to boarding and deplaning assistance? (a) As a carrier, you must...

  4. The Arms Trade and States' Duty to Ensure Respect for Humanitarian and Human Rights Law

    DEFF Research Database (Denmark)

    Brehm, Maya

    2007-01-01

    transfers has traditionally been treated as a question of arms control law, but in the recent debate about legal restrictions on states' liberty to transfer arms, norms of international humanitarian and human rights law have frequently been invoked. This article surveys the existing international legal......The unregulated international trade in conventional arms, especially in small arms and light weapons, has come to be viewed as an exacerbating factor in armed conflict, violent crime and internal repression. Concern about the negative humanitarian, development and security impact of this trade has...... been growing over the last decade. Against this backdrop, the UN General Assembly invited states in December 2006 to consider the feasibility of an instrument establishing common international standards for conventional arms transfers-also known as the ‘Arms Trade Treaty' (ATT). The legality of arms...

  5. Powered manipulator control arm

    International Nuclear Information System (INIS)

    Le Mouee, Theodore; Vertut, Jean; Marchal, Paul; Germon, J.C.; Petit, Michel

    1975-01-01

    A remote operated control arm for powered manipulators is described. It includes an assembly allowing several movements with position sensors for each movement. The number of possible arm movements equals the number of possible manipulator movements. The control systems may be interrupted as required. One part of the arm is fitted with a system to lock it with respect to another part of the arm without affecting the other movements, so long as the positions of the manipulator and the arm have not been brought into complete coincidence. With this system the locking can be ended when complete concordance is achieved [fr

  6. Do methicillin resistant staphylococcus (MRSA) carrier patients influence MRSA infection more than MRSA-carrier medical officers and MRSA-carrier family?

    Science.gov (United States)

    Dilogo, Ismail H; Arya, Abikara; Phedy; Loho, Tony

    2013-07-01

    to determine the rate of MRSA-carrier among patients, family members and health care providers, and the association between MRSA-carrier family members and health care providers on MRSA infection patient after orthopaedic surgery. this is a cross-sectional analytical study. Samples were taken consecutively during December 2010 to December 2011, consisting of postoperative patients infected with MRSA, attending family members, and the medical officers with history of contact with the patient. Swab culture were taken from nasal and axilla of all subjects. The incidence of MRSA infection, and MRSA-carrier on the patient, family members and medical officers were presented descriptively, while their association with MRSA infection was statistically tested using Fischer exact test. during the study period, there were 759 surgeries, with 4 (0.5%) patients were identified to have MRSA infection. Of these four cases, 48 subjects were enrolled. The rate of MRSA-carrier among patients, family and health care providers were 50%, 25% and 0% respectively. There were no significant association between MRSA and the rates of MRSA-carrier on the family member or health care providers. the incidence of MRSA infection, MRSA-carrier patient, MRSA-carrier health care providers, and family member carrier were 0.5%, 50%, 0%, and 25% respectively. No significant association found between MRSA-carrier on the family member or health care providers and MRSA infection patient. There were no MRSA infection found on the health care provider.

  7. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  8. Special audit report on the Department of Energy`s Arms and military-type equipment

    Energy Technology Data Exchange (ETDEWEB)

    Layton, J.C.

    1996-02-01

    Based on the activities associated with the recent recovery of the eight armored personnel carriers, a review was conducted of the Department`s controls over arms and military-type equipment in its possession. The objects were to determine whether (1) the quantity of arms and military-type equipment on hand was justified by mission needs, (2) inventory listings of arms were accurate, (3) property disposals were properly controlled and executed, and (4) loans and borrowed equipment were appropriate and accounted for accurately. The purpose of this report is to summarize the most significant issues identified and point out where the Department needs stronger controls over its inventory of arms and military-type property.

  9. Vectorisation of agrochemicals via amino acid carriers: influence of the spacer arm structure on the phloem mobility of phenylpyrrole conjugates in the Ricinus system.

    Science.gov (United States)

    Marhadour, Sophie; Wu, Hanxiang; Yang, Wen; Marivingt-Mounir, Cécile; Bonnemain, Jean-Louis; Chollet, Jean-François

    2017-09-01

    Excessive agrochemical use poses significant threats to environmental safety and human health. Reducing pesticide use without reducing yield is necessary for sustainable agriculture. Therefore, we developed a vectorisation strategy to enhance agrochemical delivery through plant amino acid carriers. In addition to a fenpiclonil conjugate recently described, three new amino acid conjugates were synthesised by coupling fenpiclonil to an l-α-amino acid. Phloem mobility of these conjugates, which exhibit different structures of the spacer arm introduced between fenpiclonil and the α-amino acid function, was studied using the Ricinus model. Conjugate L-14, which contains a triazole ring with the shortest amino acid chain, showed the best phloem systemicity among the four conjugates. By contrast, removing the triazole ring in the spacer arm did not improve systemicity. L-14 exhibited phloem systemicity at all reported pH values (pH values from 5.0 to 6.5) of the foliar apoplast, while acidic derivatives of fenpiclonil were translocated only at pH values near 5.0. The conjugates were recognised by a pH-dependent transporter system and translocated at distance in the phloem. They exhibited a broader phloem systemicity than fenpiclonil acidic derivatives within the pH value range of the foliar apoplast. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  10. Hello to Arms

    Science.gov (United States)

    2005-01-01

    This image highlights the hidden spiral arms (blue) that were discovered around the nearby galaxy NGC 4625 by the ultraviolet eyes of NASA's Galaxy Evolution Explorer. The image is composed of ultraviolet and visible-light data, from the Galaxy Evolution Explorer and the California Institute of Technology's Digitized Sky Survey, respectively. Near-ultraviolet light is colored green; far-ultraviolet light is colored blue; and optical light is colored red. As the image demonstrates, the lengthy spiral arms are nearly invisible when viewed in optical light while bright in ultraviolet. This is because they are bustling with hot, newborn stars that radiate primarily ultraviolet light. The youthful arms are also very long, stretching out to a distance four times the size of the galaxy's core. They are part of the largest ultraviolet galactic disk discovered so far. Located 31 million light-years away in the constellation Canes Venatici, NGC 4625 is the closest galaxy ever seen with such a young halo of arms. It is slightly smaller than our Milky Way, both in size and mass. However, the fact that this galaxy's disk is forming stars very actively suggests that it might evolve into a more massive and mature galaxy resembling our own. The armless companion galaxy seen below NGC 4625 is called NGC 4618. Astronomers do not know why it lacks arms but speculate that it may have triggered the development of arms in NGC 4625.

  11. Carrier priming with CRM 197 or diphtheria toxoid has a different impact on the immunogenicity of the respective glycoconjugates: biophysical and immunochemical interpretation.

    Science.gov (United States)

    Pecetta, S; Lo Surdo, P; Tontini, M; Proietti, D; Zambonelli, C; Bottomley, M J; Biagini, M; Berti, F; Costantino, P; Romano, M R

    2015-01-03

    Glycoconjugate vaccines play an enormous role in preventing infectious diseases. The main carrier proteins used in commercial conjugate vaccines are the non-toxic mutant of diphtheria toxin (CRM197), diphtheria toxoid (DT) and tetanus toxoid (TT). Modern childhood routine vaccination schedules include the administration of several vaccines simultaneously or in close sequence, increasing the concern that the repeated exposure to conjugates based on these carrier proteins might interfere with the anti-polysaccharide response. Extending previous observations we show here that priming mice with CRM197 or DT does not suppress the response to the carbohydrate moiety of CRM197 meningococcal serogroup A (MenA) conjugates, while priming with DT can suppress the response to DT-MenA conjugates. To explain these findings we made use of biophysical and immunochemical techniques applied mainly to MenA conjugates. Differential scanning calorimetry and circular dichroism data revealed that the CRM197 structure was altered by the chemical conjugation, while DT and the formaldehyde-treated form of CRM197 were less impacted, depending on the degree of glycosylation. Investigating the binding and avidity properties of IgGs induced in mice by non-conjugated carriers, we found that CRM197 induced low levels of anti-carrier antibodies, with decreased avidity for its MenA conjugates and poor binding to DT and respective MenA conjugates. In contrast, DT induced high antibody titers able to bind with comparable avidity both the protein and its conjugates but showing very low avidity for CRM197 and related conjugates. The low intrinsic immunogenicity of CRM197 as compared to DT, the structural modifications induced by glycoconjugation and detoxification processes, resulting in conformational changes in CRM197 and DT epitopes with consequent alteration of the antibody recognition and avidity, might explain the different behavior of CRM197 and DT in a carrier priming context. Copyright © 2014

  12. 49 CFR 1544.221 - Carriage of prisoners under the control of armed law enforcement officers.

    Science.gov (United States)

    2010-10-01

    ... Transportation (Continued) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRCRAFT OPERATOR SECURITY: AIR CARRIERS AND COMMERCIAL OPERATORS Operations § 1544.221 Carriage... custody of an armed law enforcement officer aboard an aircraft for which screening is required unless, in...

  13. Structural basis for phosphopantetheinyl carrier domain interactions in the terminal module of nonribosomal peptide synthetases

    Science.gov (United States)

    Liu, Ye; Zheng, Tengfei; Bruner, Steven D.

    2011-01-01

    Summary Phosphopantetheine-modified carrier domains play a central role in the template-directed, biosynthesis of several classes of primary and secondary metabolites. Fatty acids, polyketides and nonribosomal peptides are constructed on multidomain enzyme assemblies using phosphopantetheinyl thioester-linked carrier domains to traffic and activate building blocks. The carrier domain is a dynamic component of the process, shuttling pathway intermediates to sequential enzyme active sites. Here we report an approach to structurally fix carrier domain/enzyme constructs suitable for X-ray crystallographic analysis. The structure of a two-domain construct of E. coli EntF was determined with a conjugated phosphopantetheinyl-based inhibitor. The didomain structure is locked in an active orientation relevant to the chemistry of nonribosomal peptide biosynthesis. This structure provides details into the interaction of phosphopantetheine arm with the carrier domain and the active site of the thioesterase domain. PMID:22118682

  14. Changes in the bilateral pulse transit time difference with a moving arm.

    Science.gov (United States)

    Jiang, Xinge; Wei, Shoushui; Zheng, Dingchang; Huang, Peng; Liu, Chengyu

    2018-04-20

    Changes of pulse transit time (PTT) induced by arm position were studied for unilateral arm. However, consistency of the PTT changes was not validated for both arm sides. We aimed to quantify the PTT changes between horizontal and non-horizontal positions from right arm and left arm in order to explore the consistency of both arms. Twenty-four normal subjects aged between 21 and 50 (14 male and 10 female) years were enrolled. Left and right radial artery pulses were synchronously recorded from 24 healthy subjects with one arm (left or right) at five angles (90∘, 45∘, 0∘, -45∘ and -90∘) and the other arm at the horizontal level (0∘) for reference. The overall mean PTT changes at the five angles (from 90∘ to -90∘) in the left arm (right as reference) were 16.1, 12.3, -0.5, -2.5 and -2.6 ms, respectively, and in the right arm (left as reference) were 18.0, 12.6, 1.6, -1.6 and -2.0 ms, respectively. Obvious differences were not found in the PTT changes between the two arms (left arm moving or right arm moving) under each of the five different positions (all P> 0.05).

  15. Simulation of Octopus Arm Based on Coupled CPGs

    Directory of Open Access Journals (Sweden)

    Juan Tian

    2015-01-01

    Full Text Available The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs are built and a 2-dimensional dynamic model of the octopus arm is presented to explore possible strategies of the octopus movement control. And the CPGs’ signals treated as activation are added on the ventral, dorsal, and transversal sides, respectively. The effects of the octopus arm are discussed when the parameters of the CPGs are changed. Simulations show that the octopus arm movements are mainly determined by the shapes of three CPGs’ phase diagrams. Therefore, some locomotion modes are supposed to be embedded in the neuromuscular system of the octopus arm. And the octopus arm movements can be achieved by modulating the parameters of the CPGs. The results are beneficial for researchers to understand the octopus movement further.

  16. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  17. Safety requirements for the Pu carriers

    International Nuclear Information System (INIS)

    Mishima, H.

    1993-01-01

    Ministry of Transport of Japan has now set about studying requirements for Pu carriers to ensure safety. It was first studied what the basic concept of safe carriage of Pu should be, and the basic ideas have been worked out. Next the requirements for the Pu carriers were studied based on the above. There are at present no international requirements of construction and equipment for the nuclear-material carriers, but MOT of Japan has so far required special construction and equipment for the nuclear-material carriers which carry a large amount of radioactive material, such as spent fuel or low level radioactive waste, corresponding to the level of the respective potential hazard. The requirements of construction and equipment of the Pu carriers have been established considering the difference in heat generation between Pu and spent fuel, physical protection, and so forth, in addition to the above basic concept. (J.P.N.)

  18. Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Grattan, Mark W. D.; McGarry, Conor K.

    2010-01-01

    Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2±0.2, +1.8±1.6, and +7.4±0.5 mm for the R-arms, and +2.9±0.2, +2.1±0.8, and +4.9±0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1±0.4, -4.7±0.4, and -2.5

  19. Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Kigawa

    Full Text Available Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.

  20. Dynamics of malaria transmission and susceptibility to clinical malaria episodes following treatment of Plasmodium falciparum asymptomatic carriers: results of a cluster-randomized study of community-wide screening and treatment, and a parallel entomology study.

    Science.gov (United States)

    Tiono, Alfred B; Guelbeogo, Moussa W; Sagnon, N Falé; Nébié, Issa; Sirima, Sodiomon B; Mukhopadhyay, Amitava; Hamed, Kamal

    2013-11-12

    In malaria-endemic countries, large proportions of individuals infected with Plasmodium falciparum are asymptomatic and constitute a reservoir of parasites for infection of newly hatched mosquitoes. Two studies were run in parallel in Burkina Faso to evaluate the impact of systematic identification and treatment of asymptomatic carriers of P. falciparum, detected by rapid diagnostic test, on disease transmission and susceptibility to clinical malaria episodes. A clinical study assessed the incidence of symptomatic malaria episodes with a parasite density >5,000/μL after three screening and treatment campaigns ~1 month apart before the rainy season; and an entomological study determined the effect of these campaigns on malaria transmission as measured by entomological inoculation rate. The intervention arm had lower prevalence of asymptomatic carriers of asexual parasites and lower prevalence of gametocyte carriers during campaigns 2 and 3 as compared to the control arm. During the entire follow-up period, out of 13,767 at-risk subjects, 2,516 subjects (intervention arm 1,332; control arm 1,184) had symptomatic malaria. Kaplan-Meier analysis of the incidence of first symptomatic malaria episode with a parasite density >5,000/μL showed that, in the total population, the two treatment arms were similar until Week 11-12 after campaign 3, corresponding with the beginning of the malaria transmission season, after which the probability of being free of symptomatic malaria was lower in the intervention arm (logrank p entomological inoculation rate was comparable in both arms, with September peaks in both indices. Community screening and targeted treatment of asymptomatic carriers of P. falciparum had no effect on the dynamics of malaria transmission, but seemed to be associated with an increase in the treated community's susceptibility to symptomatic malaria episodes after the screening campaigns had finished. These results highlight the importance of further

  1. Co-Simulation Control of Robot Arm Dynamics in ADAMS and MATLAB

    OpenAIRE

    Luo Haitao; Liu Yuwang; Chen Zhengcang; Leng Yuquan

    2013-01-01

    The main objective of this study is how to quickly establish the virtual prototyping model of robot arm system and effectively solve trajectory tracking control for a given signal. Taking the 2-DOF robot arm as an example, a co-simulation control method is introduced to research multi-body dynamics. Using Newton-Euler and Lagrange method, respectively establish the dynamics model of robot arm and verify the correctness of equations. Firstly, the physical model of robot arm was built by PROE a...

  2. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Science.gov (United States)

    Hu, Weitong; Li, Juxiang; Su, Hai; Wang, Jiwei; Xu, Jinsong; Liu, Yanna; Huang, Ming; Cheng, Xiaoshu

    2014-01-01

    To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, Parm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  3. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    Science.gov (United States)

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, PBlood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  4. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  5. 75 FR 48409 - Establishment of the Toxic by Inhalation Hazard Common Carrier Transportation Advisory Committee

    Science.gov (United States)

    2010-08-10

    ... to the Board on issues related to the common carrier obligation with respect to the rail... advice on issues pertaining to the common carrier obligation with respect to the rail transportation of... Toxic by Inhalation Hazard Common Carrier Transportation Advisory Committee AGENCY: Surface...

  6. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  7. Realization and field emission of CdSe nano-tetrapods with different arm lengths

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Lijuan, E-mail: ljzhao@dhu.edu.c [Applied Physics Department, Donghua University, Shanghai 201620 (China); Physics Department and the Institute of Nano-Science and Technology, Hong Kong University of Science and Technology, Clear Water Bay (Hong Kong); Pang Qi [Physics Department and the Institute of Nano-Science and Technology, Hong Kong University of Science and Technology, Clear Water Bay (Hong Kong); Yang Shihe [Chemistry Department and the Institute of Nano-Science and Technology, Hong Kong University of Science and Technology, Clear Water Bay (Hong Kong); Ge Weikun; Wang Jiannong [Physics Department and the Institute of Nano-Science and Technology, Hong Kong University of Science and Technology, Clear Water Bay (Hong Kong)

    2009-08-10

    The arms of CdSe nano-tetrapods can be greatly elongated with the core diameters and arm width unchanged by multiple injections. Room-temperature absorption and photoluminescence (PL) spectra of tetrapods with different arm lengths show that these tetrapods have almost the same core size, which is consistent with the high resolution TEM results. Field emission characteristics show that the onset field required drawing a current density of approx0.1 muAcm{sup -2} from CdSe nano-tetrapods with different arm lengths are 22 Vmum{sup -1}, 9 Vmum{sup -1}, and 4 Vmum{sup -1}, respectively, and the field enhancement factors are determined to be about 218, 554, and 946, respectively. Results show that the longer is the arm of the tetrapods, the lower the turn-on field and the higher the field enhancement factor.

  8. Realization and field emission of CdSe nano-tetrapods with different arm lengths

    International Nuclear Information System (INIS)

    Zhao Lijuan; Pang Qi; Yang Shihe; Ge Weikun; Wang Jiannong

    2009-01-01

    The arms of CdSe nano-tetrapods can be greatly elongated with the core diameters and arm width unchanged by multiple injections. Room-temperature absorption and photoluminescence (PL) spectra of tetrapods with different arm lengths show that these tetrapods have almost the same core size, which is consistent with the high resolution TEM results. Field emission characteristics show that the onset field required drawing a current density of ∼0.1 μAcm -2 from CdSe nano-tetrapods with different arm lengths are 22 Vμm -1 , 9 Vμm -1 , and 4 Vμm -1 , respectively, and the field enhancement factors are determined to be about 218, 554, and 946, respectively. Results show that the longer is the arm of the tetrapods, the lower the turn-on field and the higher the field enhancement factor.

  9. Assignment of the Nance-Horan syndrome to the distal short arm of the X chromosome.

    Science.gov (United States)

    Zhu, D; Alcorn, D M; Antonarakis, S E; Levin, L S; Huang, P C; Mitchell, T N; Warren, A C; Maumenee, I H

    1990-11-01

    There are three types of X-linked cataracts recorded in Mendelian Inheritance in Man (McKusick 1988): congenital total, with posterior sutural opacities in heterozygotes; congenital, with microcornea or slight microphthalmia; and the cataract-dental syndrome or Nance-Horan (NH) syndrome. To identify a DNA marker close to the gene responsible for the NH syndrome, linkage analysis on 36 members in a three-generation pedigree including seven affected males and nine carrier females was performed using 31 DNA markers. A LOD score of 1.662 at theta = 0.16 was obtained with probe 782 from locus DXS85 on Xp22.2-p22.3. Negative LOD scores were found at six loci on the short arm, one distal to DXS85, five proximal, and six probes spanning the long arm were highly negative. These results make the assignment of the locus for NH to the distal end of the short arm of the X chromosome likely.

  10. Digital holography based on multiwavelength spatial-bandwidth-extended capturing-technique using a reference arm (Multi-SPECTRA).

    Science.gov (United States)

    Tahara, Tatsuki; Kaku, Toru; Arai, Yasuhiko

    2014-12-01

    Single-shot digital holography based on multiwavelength spatial-bandwidth-extended capturing-technique using a reference arm (Multi-SPECTRA) is proposed. Both amplitude and quantitative phase distributions of waves containing multiple wavelengths are simultaneously recorded with a single reference arm in a single monochromatic image. Then, multiple wavelength information is separately extracted in the spatial frequency domain. The crosstalk between the object waves with different wavelengths is avoided and the number of wavelengths recorded with both a single-shot exposure and no crosstalk can be increased, by a large spatial carrier that causes the aliasing, and/or by use of a grating. The validity of Multi-SPECTRA is quantitatively, numerically, and experimentally confirmed.

  11. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [National Research Council Canada, National Science Infrastructure portfolio, Herzberg Astronomy and Astrophysics, 5071 West Saanich Road, Victoria, B.C., V9E 2E7 (Canada)

    2014-07-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  12. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  13. Reassignment of Drosophila willistoni Genome Scaffolds to Chromosome II Arms.

    Science.gov (United States)

    Garcia, Carolina; Delprat, Alejandra; Ruiz, Alfredo; Valente, Vera L S

    2015-10-04

    Drosophila willistoni is a geographically widespread Neotropical species. The genome of strain Gd-H4-1 from Guadeloupe Island (Caribbean) was sequenced in 2007 as part of the 12 Drosophila Genomes Project. The assembled scaffolds were joined based on conserved linkage and assigned to polytene chromosomes based on a handful of genetic and physical markers. This paucity of markers was particularly striking in the metacentric chromosome II, comprised two similarly sized arms, IIL and IIR, traditionally considered homologous to Muller elements C and B, respectively. In this paper we present the cytological mapping of 22 new gene markers to increase the number of markers mapped by in situ hybridization and to test the assignment of scaffolds to the polytene chromosome II arms. For this purpose, we generated, by polymerase chain reaction amplification, one or two gene probes from each scaffold assigned to the chromosome II arms and mapped these probes to the Gd-H4-1 strain's polytene chromosomes by nonfluorescent in situ hybridization. Our findings show that chromosome arms IIL and IIR correspond to Muller elements B and C, respectively, directly contrasting the current homology assignments in D. willistoni and constituting a major reassignment of the scaffolds to chromosome II arms. Copyright © 2015 Garcia et al.

  14. Photoelectric radar servo control system based on ARM+FPGA

    Science.gov (United States)

    Wu, Kaixuan; Zhang, Yue; Li, Yeqiu; Dai, Qin; Yao, Jun

    2016-01-01

    In order to get smaller, faster, and more responsive requirements of the photoelectric radar servo control system. We propose a set of core ARM + FPGA architecture servo controller. Parallel processing capability of FPGA to be used for the encoder feedback data, PWM carrier modulation, A, B code decoding processing and so on; Utilizing the advantage of imaging design in ARM Embedded systems achieves high-speed implementation of the PID algorithm. After the actual experiment, the closed-loop speed of response of the system cycles up to 2000 times/s, in the case of excellent precision turntable shaft, using a PID algorithm to achieve the servo position control with the accuracy of + -1 encoder input code. Firstly, This article carry on in-depth study of the embedded servo control system hardware to determine the ARM and FPGA chip as the main chip with systems based on a pre-measured target required to achieve performance requirements, this article based on ARM chip used Samsung S3C2440 chip of ARM7 architecture , the FPGA chip is chosen xilinx's XC3S400 . ARM and FPGA communicate by using SPI bus, the advantage of using SPI bus is saving a lot of pins for easy system upgrades required thereafter. The system gets the speed datas through the photoelectric-encoder that transports the datas to the FPGA, Then the system transmits the datas through the FPGA to ARM, transforms speed datas into the corresponding position and velocity data in a timely manner, prepares the corresponding PWM wave to control motor rotation by making comparison between the position data and the velocity data setted in advance . According to the system requirements to draw the schematics of the photoelectric radar servo control system and PCB board to produce specially. Secondly, using PID algorithm to control the servo system, the datas of speed obtained from photoelectric-encoder is calculated position data and speed data via high-speed digital PID algorithm and coordinate models. Finally, a

  15. The effect of arm sling on balance in patients with hemiplegia.

    Science.gov (United States)

    Acar, Merve; Karatas, Gulcin Kaymak

    2010-10-01

    The aim of this study was to investigate the effect of an arm sling on balance in patients with, hemiplegia following a stroke. Twenty-six patients with hemiplegia (11 men, 15 women) who had, shoulder subluxation were enrolled in the study. Balance was evaluated by the Berg Balance Scale, the, Functional Reach test, and a static balance index which was measured by the Kinesthetic Ability, Trainer 3000. Balance tests were performed twice, with arm sling and without arm sling use. Results of, this study show that the Berg Balance Scores and static balance index ameliorated with arm sling use (p=0.005 and p=0.004, respectively). Likewise, the Functional Reach test was better when performed with an arm sling (p=0.039). In conclusion, arm slings have a beneficial effect on balance in patients, with hemiplegia. An arm sling may be applied for its possible beneficial effect on balance especially in, the early phases of stroke rehabilitation while the upper extremity is still flaccid and arm swing is, reduced. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  17. Highly immunogenic and fully synthetic peptide-carrier constructs targetting GnRH

    DEFF Research Database (Denmark)

    Beekman, N.J.C.M.; Schaaper, W.M.M.; Turkstra, J.A.

    1999-01-01

    To use peptides as synthetic vaccines, they have to be coupled to a carrier protein to make them more immunogenic. Coupling efficiency between a carrier protein and a peptide, however, is difficult to control with respect to loading density of the peptide, This makes these carrier proteins poorly...... for the induction of antibodies against GnRH and immunocastration of pigs....

  18. Ultrafast carrier thermalization and cooling dynamics in few-layer MoS2.

    Science.gov (United States)

    Nie, Zhaogang; Long, Run; Sun, Linfeng; Huang, Chung-Che; Zhang, Jun; Xiong, Qihua; Hewak, Daniel W; Shen, Zexiang; Prezhdo, Oleg V; Loh, Zhi-Heng

    2014-10-28

    Femtosecond optical pump-probe spectroscopy with 10 fs visible pulses is employed to elucidate the ultrafast carrier dynamics of few-layer MoS2. A nonthermal carrier distribution is observed immediately following the photoexcitation of the A and B excitonic transitions by the ultrashort, broadband laser pulse. Carrier thermalization occurs within 20 fs and proceeds via both carrier-carrier and carrier-phonon scattering, as evidenced by the observed dependence of the thermalization time on the carrier density and the sample temperature. The n(-0.37 ± 0.03) scaling of the thermalization time with carrier density suggests that equilibration of the nonthermal carrier distribution occurs via non-Markovian quantum kinetics. Subsequent cooling of the hot Fermi-Dirac carrier distribution occurs on the ∼ 0.6 ps time scale via carrier-phonon scattering. Temperature- and fluence-dependence studies reveal the involvement of hot phonons in the carrier cooling process. Nonadiabatic ab initio molecular dynamics simulations, which predict carrier-carrier and carrier-phonon scattering time scales of 40 fs and 0.5 ps, respectively, lend support to the assignment of the observed carrier dynamics.

  19. Everyday movement and use of the arms: Relationship in children with hemiparesis differs from adults.

    Science.gov (United States)

    Sokal, Brad; Uswatte, Gitendra; Vogtle, Laura; Byrom, Ezekiel; Barman, Joydip

    2015-01-01

    In adults with hemiparesis amount of movement of the more-affected arm is related to its amount of use in daily life. In children, little is known about everyday arm use. This report examines the relationships between everyday movement of the more-affected arm and its (a) everyday use and (b) motor capacity in children with hemiparesis. Participants were 28 children with a wide range of upper-extremity hemiparesis subsequent to cerebral palsy due to pre- or peri-natal stroke. Everyday movement of the more-affected arm was assessed by putting accelerometers on the children's forearms for three days. Everyday use of that arm and its motor capacity were assessed with the Pediatric Motor Activity Log-Revised and Pediatric Arm Function Test, respectively. Intensity of everyday movement of the more-affected arm was correlated with its motor capacity (rs ≥ 0.52, ps ≤ 0.003). However, everyday movement of that arm was not correlated with its everyday use (rs ≤ 0.30, ps ≥ $ 0.126). In children with upper-extremity hemiparesis who meet the study intake criteria amount of movement of the more-affected arm in daily life is not related to its amount to use, suggesting that children differ from adults in this respect.

  20. Drug targeting and the carriers. Application to chemoembolization and medical imaging

    International Nuclear Information System (INIS)

    Puisieux, F.; Benoit, J.P.; Roblot-Treupel, L.

    1987-01-01

    The last fifteen years have seen an increased interest in drug targeting which can be considered as a new way to control the body distribution of drugs when associated with an appropriate carrier. The systems currently studied possess different structures (macromolecular, vesicular and particular) and can be classified into carriers of first, second and third generation. After a brief review of the three types of carriers, this paper focuses on their respective interest in the different fields of radiology: carriers of first generation (microcapsules, microspheres) in chemoembolization, carriers of second generation (liposomes, nanocapsules, nanospheres) in conventional radiology, in computerized tomography, in scintigraphy, in RMN; carriers of third generation (monoclonal antibodies...) in immunoscintigraphy of tumors [fr

  1. Kinematic feedback control laws for generating natural arm movements

    International Nuclear Information System (INIS)

    Kim, Donghyun; Jang, Cheongjae; Park, Frank C

    2014-01-01

    We propose a stochastic optimal feedback control law for generating natural robot arm motions. Our approach, inspired by the minimum variance principle of Harris and Wolpert (1998 Nature 394 780–4) and the optimal feedback control principles put forth by Todorov and Jordan (2002 Nature Neurosci. 5 1226–35) for explaining human movements, differs in two crucial respects: (i) the endpoint variance is minimized in joint space rather than Cartesian hand space, and (ii) we ignore the dynamics and instead consider only the second-order differential kinematics. The feedback control law generating the motions can be straightforwardly obtained by backward integration of a set of ordinary differential equations; these equations are obtained exactly, without any linear–quadratic approximations. The only parameters to be determined a priori are the variance scale factors, and for both the two-DOF planar arm and the seven-DOF spatial arm, a table of values is constructed based on the given initial and final arm configurations; these values are determined via an optimal fitting procedure, and consistent with existing findings about neuromuscular motor noise levels of human arm muscles. Experiments conducted with a two-link planar arm and a seven-DOF spatial arm verify that the trajectories generated by our feedback control law closely resemble human arm motions, in the sense of producing nearly straight-line hand trajectories, having bell-shaped velocity profiles, and satisfying Fitts Law. (paper)

  2. Galaxy Zoo: constraining the origin of spiral arms

    Science.gov (United States)

    Hart, Ross E.; Bamford, Steven P.; Keel, William C.; Kruk, Sandor J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.

    2018-05-01

    Since the discovery that the majority of low-redshift galaxies exhibit some level of spiral structure, a number of theories have been proposed as to why these patterns exist. A popular explanation is a process known as swing amplification, yet there is no observational evidence to prove that such a mechanism is at play. By using a number of measured properties of galaxies, and scaling relations where there are no direct measurements, we model samples of SDSS and S4G spiral galaxies in terms of their relative halo, bulge and disc mass and size. Using these models, we test predictions of swing amplification theory with respect to directly measured spiral arm numbers from Galaxy Zoo 2. We find that neither a universal cored or cuspy inner dark matter profile can correctly predict observed numbers of arms in galaxies. However, by invoking a halo contraction/expansion model, a clear bimodality in the spiral galaxy population emerges. Approximately 40 per cent of unbarred spiral galaxies at z ≲ 0.1 and M* ≳ 1010M⊙ have spiral arms that can be modelled by swing amplification. This population display a significant correlation between predicted and observed spiral arm numbers, evidence that they are swing amplified modes. The remainder are dominated by two-arm systems for which the model predicts significantly higher arm numbers. These are likely driven by tidal interactions or other mechanisms.

  3. Hand-Arm vibration assessment among tiller operator

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-08-01

    Result: Results of the present study indicated that in all measured situations, exposure to hand arm vibration was higher than the standard limit suggested by Iranian occupational health committee and there was risk of vibration-induced disorders. The maximum exposure to vibration is in plowing ground. Exposure to hand arm vibration in three modes of plowing, transmission and natural, were respectively 16.95, 14.16 and 8.65 meters per second squared. Additionally, in all situations, vibration exposure was highest in the X-axis in comparison with Z- and Y-axes. .Conclusion: This study emphasizes on the need to provide intervention and controlling and managing strategies in order to eliminate or reduce vibration transmitted from tiller to operators hand and arm and also prevent to serious problems including neurovascular disorders, discomfort and white finger syndrome. Meanwhile, more studies are necessary to identify the sources of vibration on different models of tiller.

  4. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  5. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  6. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  7. Have Third-World Arms Industries Reduced Arms Imports?

    OpenAIRE

    Looney, R.E.

    1989-01-01

    Current Research on Peace and Violence, no. 1, 1989. Refereed Journal Article In 1945 only Argentina, Brazil, India and South Africa in the Third World possessed domestic arms industries which produced weapons systems other than small arms and ammunition (SIPRI, 1987, 76).

  8. Inconsistency between simultaneous blood pressure measurements in the arm, forearm, and leg in anesthetized children.

    Science.gov (United States)

    Keidan, Ilan; Sidi, Avner; Ben-Menachem, Erez; Tene, Yael; Berkenstadt, Haim

    2014-02-01

    To determine the accuracy and precision of simultaneous noninvasive blood pressure (NIBP) measurement in the arm, forearm, and ankle in anesthetized children. Prospective, randomized study. University medical center. 101 ASA physical status 1 and 2 children (aged 1-8 yrs) scheduled for elective surgery with general anesthesia. Simultaneous NIBP measurements were recorded at the arm, forearm, and ankle at 5-minute intervals. The systolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 63% and 29% of measurements, and within the ± 20% range in 85% and 67% of measurements, respectively. The diastolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 42% and 44% and within the ± 20% range in 67% and 74% of measurements, respectively. In patients in whom the initial three NIBP measurements were within the ± 20% range between the forearm and arm, 86% of the subsequent measurements were also within that limit. Forearm and ankle NIBP measurements are unreliable and inconsistent with NIBP measured in the arm of anesthetized children. These alternative BP measurement sites are not reliable in accuracy (comparison with reference "gold" standard) and precision (reproducibility). Copyright © 2014 Elsevier Inc. All rights reserved.

  9. On motions of a carrier with a mobile load along a rough inclined plane

    Science.gov (United States)

    Bilchenko, Grigory; Bilchenko, Grigory; Bilchenko, Nataly

    2018-05-01

    A mechanical system consisting of a carrier and a load is considered. The load can move respectively to the carrier according to a predetermined motion law. The carrier can move translationally along a rectilinear trajectory on a rough inclined plane. The trajectory is the line of the greatest descent. The axis of the rectilinear channel, along which the load moves, is located in a vertical plane passing through the trajectory of the carrier. The Coulomb dry friction model is applied for simulation the forces of resistance to the motion of the carrier from the side of the underlying inclined plane. The extreme value of plane inclination angle at which the carrier is at rest, when the load is stationary, is obtained by taking into account the frictional forces of sliding at rest. Differential equations of motion of a carrier with a load moving with respect to the carrier are obtained taking into account the requirement of motion of the carrier along an inclined plane without detachment. The determining relationships are given which made it possible to classify the types of carrier motion when the channel setting angle and the plane inclination angle are related by a certain inequality. The results of computational experiments are presented.

  10. The metabolic cost of human running: is swinging the arms worth it?

    Science.gov (United States)

    Arellano, Christopher J; Kram, Rodger

    2014-07-15

    Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms across the chest (CHEST) and (3) holding the hands on top of the head (HEAD). We hypothesized that running without arm swing would demand a greater metabolic cost than running with arm swing. Indeed, when compared with running using normal arm swing, we found that net metabolic power demand was 3, 9 and 13% greater for the BACK, CHEST and HEAD conditions, respectively (all Prunning without arm swing, subjects significantly increased the peak-to-peak amplitudes of both shoulder and pelvis rotation about the vertical axis, most likely a compensatory strategy to counterbalance the rotational angular momentum of the swinging legs. In conclusion, our findings support our general hypothesis that swinging the arms reduces the metabolic cost of human running. Our findings also demonstrate that arm swing minimizes torso rotation. We infer that actively swinging the arms provides both metabolic and biomechanical benefits during human running. © 2014. Published by The Company of Biologists Ltd.

  11. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  12. Arm to leg coordination in elite butterfly swimmers.

    Science.gov (United States)

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  13. Two carrier temperatures non-equilibrium generalized Planck law for semiconductors

    Science.gov (United States)

    Gibelli, François; Lombez, Laurent; Guillemoles, Jean-François

    2016-10-01

    Planck's law of radiation describes the light emitted by a blackbody. This law has been generalized in the past for the case of a non-blackbody material having a quasi Fermi-level splitting: the lattice of the material and the carriers are then considered in an isothermal regime. Hot carrier spectroscopy deals with carriers out of the isothermal regime, as their respective temperatures (THe ≠ THh) are considered to be different than that of the lattice (TL). Here we show that Fermi-Dirac distribution temperature for each type of carrier still determine an effective radiation temperature: an explicit relationship is given involving the effective masses. Moreover, we show how to determine, in principle with an additional approximation, the carrier temperatures (THe, THh) and the corresponding absolute electrochemical potentials from photoluminescence measurements.

  14. Analysis of carrier transport and carrier trapping in organic diodes with polyimide-6,13-Bis(triisopropylsilylethynyl)pentacene double-layer by charge modulation spectroscopy and optical second harmonic generation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Eunju, E-mail: elim@dankook.ac.kr, E-mail: taguchi.d.aa@m.titech.ac.jp, E-mail: iwamoto@pe.titech.ac.jp [Department of Applied Physics, Institute of Nanosensor and Biotechnology, Dankook University, Jukjeon-dong, Gyeonggi-do 448-701 (Korea, Republic of); Taguchi, Dai, E-mail: elim@dankook.ac.kr, E-mail: taguchi.d.aa@m.titech.ac.jp, E-mail: iwamoto@pe.titech.ac.jp; Iwamoto, Mitsumasa, E-mail: elim@dankook.ac.kr, E-mail: taguchi.d.aa@m.titech.ac.jp, E-mail: iwamoto@pe.titech.ac.jp [Department of Physical Electronics, Tokyo Institute of Technology 2-12-1, O-okayama, Meguro-ku, Tokyo 152-8552 (Japan)

    2014-08-18

    We studied the carrier transport and carrier trapping in indium tin oxide/polyimide (PI)/6,13-Bis(triisopropylsilylethynyl)pentacene (TIPS-pentacene)/Au diodes by using charge modulation spectroscopy (CMS) and time-resolved electric field induced optical second harmonic generation (TR-EFISHG) measurements. TR-EFISHG directly probes the spatial carrier behaviors in the diodes, and CMS is useful in explaining the carrier motion with respect to energy. The results clearly indicate that the injected carriers move across TIPS-pentacene thorough the molecular energy states of TIPS-pentacene and accumulate at the PI/TIPS-pentacene interface. However, some carriers are trapped in the PI layers. These findings take into account the capacitance-voltage and current-voltage characteristics of the diodes.

  15. Estimation of Height from Arm Span in 6-11 Years Children in Odisha, India

    Directory of Open Access Journals (Sweden)

    Snigdha Prava Mishra

    2017-10-01

    Full Text Available Introduction: Standing height is an important anthropometric parameter to track longitudinal growth, to estimate body fatness and to calculate energy requirement. Measurement of height may be difficult in children who cannot stand. Aim: To establish regression equation for estimation of height from arm span in children. To check comparative relevancy of this equation with fixed height-to-arm span ratio (HAR for estimation of height. Materials and Methods: A cross-sectional study was conducted with 6-11 years school children (n=1465, Boys=774, Girls=691 in state of Odisha, India. Height was measured by portable stadiometer and arm span was measured by fiberglass measuring tape to nearest 0.1 cm. Pearson correlation and regression analysis was carried out between height and arm span data. p<0.05 (two tail was considered statistically significant. Results: Mean height and arm span in boys (124.16±8.74 cm and 125.57±10.43 cm respectively was significantly more (p<0.001 than height and arm span in girls (121.18±10.37 cm and 121.50±11.68 cm respectively. Mean HAR was 0.9942±0.0279. Correlation between height and arm span in boys was r = 0.94 (p<0.001 and in girls was r = 0.96 (p<0.001. Overall correlation coefficient was r = 0.95 (p<0.001. Regression equation for estimation of height from arm span was established: Height (cm = 0.8192 * arm span (cm + 21.46. Conclusion: Height in children of 6-11 years showed strong positive correlation with arm span. Regression equation established from this study can be used to estimate height from arm span. This estimation is more reliable than estimation of height from HAR.

  16. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  17. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  18. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  19. Supporting the President's Arms Control and Nonproliferation Agenda: Transparency and Verification for Nuclear Arms Reductions

    International Nuclear Information System (INIS)

    Doyle, James E.; Meek, Elizabeth

    2009-01-01

    near-term (1-4) years and longer-term (5-10) years planning horizons. Some final observations include acknowledging the enduring nature of several key objectives on the Obama Administration's arms control and nonproliferation agenda. The CTBT, FMCT, bilateral nuclear arms reductions and strengthening the NPT have been sought by successive U.S. Administrations for nearly thirty years. Efforts towards negotiated arms control, although de-emphasized by the G.W. Bush Administration, have remained a pillar of U.S. national security strategy for decades and are likely to be of enduring if not increasing importance for decades to come. Therefore revitalization and expansion of USG capabilities in this area can be a positive legacy no matter what near-term arms control goals are achieved over the next four years. This is why it is important to reconstruct integrated bureaucratic, legislative, budgetary and diplomatic strategies to sustain the arms control and nonproliferation agenda. In this endeavor some past lessons must be taken to heart to avoid bureaucratic overkill and keep interagency policy-making and implementation structures lean and effective. On the Technical side a serious, sustained multilateral program to develop, down select and performance test nuclear weapons dismantlement verification technologies and procedures should be immediately initiated. In order to make this happen the United States and Russia should join with the UK and other interested states in creating a sustained, full-scale research and development program for verification at their respective nuc1ear weapons and defense establishments. The goals include development of effective technologies and procedures for: (1) Attribute measurement systems to certify nuclear warheads and military fissile materials; (2) Chain-of-custody methods to track items after they are authenticated and enter accountability; (3) Transportation monitoring; (4) Storage monitoring; (5) Fissile materials conversion

  20. Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, E.U.; Sebastian, D.; Andrusak, G.F. [Fish and Wildlife Science and Allocation, Ministry of Environment, Province of British Columbia

    2009-07-01

    declined in 2006 to approximately 400,000 spawners. The Lardeau River escapement also declined with approximately 100,000 spawners. Escapement in the South Arm tributaries in 2006 was similar to 2005 with virtually no spawners. The mean size of female and male kokanee from Meadow Creek was larger than the past three years (24.9 cm and 25.2 cm, respectively) and larger than the long term average (25.2 cm). This is indicative of a density dependent growth response as a decline in in-lake abundance and returning spawners occurred. Spring hydroacoustic estimates indicated low densities of South Arm kokanee with most of the North Arm fry remaining at the most northerly stations. By the fall, the distribution of kokanee from the North Arm to the South Arm was fairly uniform, a normal occurrence in Kootenay Lake. Fall hydroacoustic estimates in 2006 increased to approximately 22 million kokanee.

  1. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Directory of Open Access Journals (Sweden)

    Weitong Hu

    Full Text Available OBJECTIVES: To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r induced by one arm ischemia correlates with flow-mediated dilatation (FMD. METHODS: Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives. Following baseline diameter (D0 and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD was calculated as the percentage increase of artery diameter (ΔD/D0. The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r. RESULTS: At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05, which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05. A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001. Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01 was similar to that between age and D/D0 (r = -0.398, P<0.01. Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. CONCLUSION: The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  2. An ARM Mobile Facility Designed for Marine Deployments

    Science.gov (United States)

    Wiscombe, W. J.

    2007-05-01

    The U.S. Dept. of Energy's ARM (Atmospheric Radiation Measurements) Program is designing a Mobile Facility exclusively for marine deployments. This marine facility is patterned after ARM's land Mobile Facility, which had its inaugural deployment at Point Reyes, California, in 2005, followed by deployments to Niger in 2006 and Germany in 2007 (ongoing), and a planned deployment to China in 2008. These facilities are primarily intended for the study of clouds, radiation, aerosols, and surface processes with a goal to include these processes accurately in climate models. They are preferably embedded within larger field campaigns which provide context. They carry extensive instrumentation (in several large containers) including: cloud radar, lidar, microwave radiometers, infrared spectrometers, broadband and narrowband radiometers, sonde-launching facilities, extensive surface aerosol measurements, sky imagers, and surface latent and sensible heat flux devices. ARM's Mobile Facilities are designed for 6-10 month deployments in order to capture climatically-relevant datasets. They are available to any scientist, U.S. or international, who wishes to submit a proposal during the annual Spring call. The marine facility will be adapted to, and ruggedized for, the harsh marine environment and will add a scanning two-frequency radar, a boundary-layer wind profiler, a shortwave spectrometer, and aerosol instrumentation adapted to typical marine aerosols like sea salt. Plans also include the use of roving small UAVs, automated small boats, and undersea autonomous vehicles in order to address the point-to-area-average problem which is so crucial for informing climate models. Initial deployments are planned for small islands in climatically- interesting cloud regimes, followed by deployments on oceanic platforms (like decommissioned oil rigs and the quasi-permanent platform of this session's title) and eventually on large ships like car carriers plying routine routes.

  3. ARM Airborne Carbon Measurements (ARM-ACME) and ARM-ACME 2.5 Final Campaign Reports

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tom, M. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [NOAA Earth Systems Research Lab., Boulder, CO (United States)

    2016-01-01

    We report on a 5-year multi-institution and multi-agency airborne study of atmospheric composition and carbon cycling at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, with scientific objectives that are central to the carbon-cycle and radiative-forcing goals of the U.S. Global Change Research Program and the North American Carbon Program (NACP). The goal of these measurements is to improve understanding of 1) the carbon exchange of the Atmospheric Radiation Measurement (ARM) SGP region; 2) how CO2 and associated water and energy fluxes influence radiative-forcing, convective processes, and CO2 concentrations over the ARM SGP region, and 3) how greenhouse gases are transported on continental scales.

  4. Mobility of charge carriers in porous silicon layers

    International Nuclear Information System (INIS)

    Forsh, P. A.; Martyshov, M. N.; Latysheva, A. P.; Vorontsov, A. S.; Timoshenko, V. Yu.; Kashkarov, P. K.

    2008-01-01

    The (conduction) mobility of majority charge carriers in porous silicon layers of the n and p types is estimated by joint measurements of electrical conductivity and free charge carrier concentration, which is determined from IR absorption spectra. Adsorption of donor and acceptor molecules leading to a change in local electric fields in the structure is used to identify the processes controlling the mobility in porous silicon. It is found that adsorption of acceptor and donor molecules at porous silicon of the p and n types, respectively, leads to a strong increase in electrical conductivity, which is associated with an increase in the concentration of free carrier as well as in their mobility. The increase in the mobility of charge carriers as a result of adsorption indicates the key role of potential barriers at the boundaries of silicon nanocrystals and may be due to a decrease in the barrier height as a result of adsorption

  5. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, Sebastien [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of the ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.

  6. Arm circumference: its importance for dialysis patients in the obesity era.

    Science.gov (United States)

    Akpolat, Tekin; Kaya, Coşkun; Utaş, Cengiz; Arinsoy, Turgay; Taşkapan, Hülya; Erdem, Emre; Yilmaz, M Emin; Ataman, Rezzan; Bozfakioğlu, Semra; Özener, Çetin; Karayaylali, Ibrahim; Kazancioğlu, Rümeyza; Çamsari, Taner; Yavuz, Mahmut; Ersoy, Fevzi; Duman, Soner; Ateş, Kenan

    2013-08-01

    The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.

  7. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  8. ARM Mentor Selection Process

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, D. L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.

  9. Why do arms extract less oxygen than legs during exercise?

    DEFF Research Database (Denmark)

    Calbet, J A L; Holmberg, H-C; Rosdahl, H

    2005-01-01

    To determine whether conditions for O2 utilization and O2 off-loading from the hemoglobin are different in exercising arms and legs, six cross-country skiers participated in this study. Femoral and subclavian vein blood flow and gases were determined during skiing on a treadmill at approximately 76...... exercise (diagonal stride), the corresponding mean values were 93 and 85% (n = 3; P hemoglobin to be 50% saturated (P50: r = 0.93, P ...Hg, respectively. Because conditions for O2 off-loading from the hemoglobin are similar in leg and arm muscles, the observed differences in maximal arm and leg O2 extraction should be attributed to other factors, such as a higher heterogeneity in blood flow distribution, shorter mean transit time, smaller...

  10. The arms race control

    International Nuclear Information System (INIS)

    Nemo, J.

    2010-01-01

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  11. Actigraphy Detects Greater Intra-Individual Variability During Gait in Non-Manifesting LRRK2 Mutation Carriers.

    Science.gov (United States)

    van den Heuvel, Lieneke; Lim, Andrew S; Visanji, Naomi P; Huang, Jana; Ghate, Taneera; Mestre, Tiago A; AlDakheel, Amaal; Connolly, Barbara S; Gasca-Salas, Carmen; Kern, Drew S; Jain, Jennifer; Slow, Elizabeth J; Pondal, Margarita; Faust-Socher, Achinoam; Rogaeva, Ekaterina; Tomlinson, George; Lang, Anthony E; Marras, Connie

    2018-01-01

    With recent advances in the search for disease-modifying therapies for Parkinson's disease (PD) the importance of identifying prodromal markers becomes greater. Non-manifesting LRRK2 mutation carriers (NMC) are at risk for developing PD, and provide a population in which to identify possible markers. The aim of this study was to test the hypothesis that NMC have differences in daily activity, fragmentation of sleep, arm swing asymmetry, and movement variability during walking, detectable by actigraphy, as compared to matched control subjects. Eleven NMC, fourteen PD patients (4 LRRK2-PD, 10 idiopathic PD (iPD)), and twenty-nine controls wore wristbands containing an accelerometer for seven days, and performed a daily walking task. Outcome measures included daily activity, fragmentation of activity, fragmentation of sleep, arm swing asymmetry during walking, and intra-individual variability. Compared to healthy controls, both NMC and LRRK2/iPD showed higher intra-individual variability in activity during walking compared to healthy controls. Individuals with LRRK2-PD/iPD, but not NMC, tend to have lower activity levels, more arm swing asymmetry and less increase of arm swing with transition from slow to faster walking speed compared to healthy controls. Higher intra-individual variability of gait-associated movements might be a useful biomarker of prodromal PD. These results encourage replication in a larger sample and longitudinal analysis is warranted.

  12. How do octopuses use their arms?

    Science.gov (United States)

    Mather, J A

    1998-09-01

    A taxonomy of the movement patterns of the 8 flexible arms of octopuses is constructed. Components consist of movements of the arm itself, the ventral suckers and their stalks, as well as the relative position of arms and the skin web between them. Within 1 arm, combinations of components result in a variety of behaviors. At the level of all arms, 1 group of behaviors is described as postures, on the basis of the spread of all arms and the web to make a 2-dimensional surface whose position differs in the 3rd dimension. Another group of arm behaviors is actions, more or less coordinated and involving several to all arms. Arm control appears to be based on radial symmetry, relative equipotentiality of all arms, relative independence of each arm, and separability of components within the arm. The types and coordination of arm behaviors are discussed with relationship to biomechanical limits, muscle structures, and neuronal programming.

  13. Arm coordination in octopus crawling involves unique motor control strategies.

    Science.gov (United States)

    Levy, Guy; Flash, Tamar; Hochner, Binyamin

    2015-05-04

    To cope with the exceptional computational complexity that is involved in the control of its hyper-redundant arms [1], the octopus has adopted unique motor control strategies in which the central brain activates rather autonomous motor programs in the elaborated peripheral nervous system of the arms [2, 3]. How octopuses coordinate their eight long and flexible arms in locomotion is still unknown. Here, we present the first detailed kinematic analysis of octopus arm coordination in crawling. The results are surprising in several respects: (1) despite its bilaterally symmetrical body, the octopus can crawl in any direction relative to its body orientation; (2) body and crawling orientation are monotonically and independently controlled; and (3) contrasting known animal locomotion, octopus crawling lacks any apparent rhythmical patterns in limb coordination, suggesting a unique non-rhythmical output of the octopus central controller. We show that this uncommon maneuverability is derived from the radial symmetry of the arms around the body and the simple pushing-by-elongation mechanism by which the arms create the crawling thrust. These two together enable a mechanism whereby the central controller chooses in a moment-to-moment fashion which arms to recruit for pushing the body in an instantaneous direction. Our findings suggest that the soft molluscan body has affected in an embodied way [4, 5] the emergence of the adaptive motor behavior of the octopus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. CyARM: Haptic Sensing Device for Spatial Localization on Basis of Exploration by Arms

    Directory of Open Access Journals (Sweden)

    Junichi Akita

    2009-01-01

    Full Text Available We introduce a new type of perception aid device based on user's exploration action, which is named as CyARM (acronym of “Cyber Arm”. The user holds this device in her/his arm, the extension of the arm is controlled by tension in wires, which are attached to her/his body according to the distance to the object. This user interface has unique characteristics that give users the illusion of an imaginary arm that extends to existing objects. The implementations of CyARM and our two experiments to investigate the efficiency and effectiveness of CyARM are described. The results show that we could confirm that CyARM can be used to recognize the presence of an object in front of the user and to measure the relative distance to the object.

  15. The effect of unilateral arm swing motion on lower extremity running mechanics associated with injury risk.

    Science.gov (United States)

    Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A

    2018-06-01

    Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.

  16. Study of Charge Carrier Transport in GaN Sensors

    Science.gov (United States)

    Gaubas, Eugenijus; Ceponis, Tomas; Kuokstis, Edmundas; Meskauskaite, Dovile; Pavlov, Jevgenij; Reklaitis, Ignas

    2016-01-01

    Capacitor and Schottky diode sensors were fabricated on GaN material grown by hydride vapor phase epitaxy and metal-organic chemical vapor deposition techniques using plasma etching and metal deposition. The operational characteristics of these devices have been investigated by profiling current transients and by comparing the experimental regimes of the perpendicular and parallel injection of excess carrier domains. Profiling of the carrier injection location allows for the separation of the bipolar and the monopolar charge drift components. Carrier mobility values attributed to the hydride vapor phase epitaxy (HVPE) GaN material have been estimated as μe = 1000 ± 200 cm2/Vs for electrons, and μh = 400 ± 80 cm2/Vs for holes, respectively. Current transients under injection of the localized and bulk packets of excess carriers have been examined in order to determine the surface charge formation and polarization effects. PMID:28773418

  17. Upper arm fat and muscle in stunted and non-stunted children aged 0-24 months

    Directory of Open Access Journals (Sweden)

    Bagus Winandi Arundito

    2018-01-01

    Full Text Available Background The prevalence of stunting in Indonesia is high, with particularly negative impacts on health during childhood as well as adolescence. Stunting impacts the health of children as well as adults, especially with  regards to future obesity. Therefore, evaluating body composition of stunted children before 2 years of age is necessary. Objective To compare upper arm fat and muscle measurements in stunted and non-stunted children aged 0-24 months of age. Methods We analyzed secondary data of the Division of Nutrition and Metabolic Disease, Department of Child Health, Universitas Gadjah Mada Medical School, Yogyakarta which were collected using cluster random sampling from the Yogyakarta Special Province. We compared upper arm fat area (UFA, including the upper arm fat area estimate (UFE and the upper arm fat percentage (UFP, as well as upper arm muscle area (UMA and upper arm muscle area estimate (UME, among stunted and non-stunted children aged 0-24 months. Results We analyzed 2,195 children. The prevalence of stunting was 354/2,195 (16.1%. The UFA, UFE, and UFP among stunted children were significantly lower compared to non-stunted children aged 7-12 months [UFA: 4.48 vs. 5.05 cm2 (P <0.001, respectively; UFE: 4.88 vs. 5.55 cm2 (P <0.001, respectively; and UFP: 30.82 vs. 32.58% (P = 0.03, respectively]. The UMA in children aged 7-12 months was also significantly lower in stunted than in non-stunted children [11.31 vs. 11.79 cm2 (P = 0.02, respectively], as well as in children aged 13-24 months [11.05 vs. 11.75 cm2 (P <0.001, respectively]. In addition, the UME in children aged 13-24 months was significantly lower in stunted compared to non-stunted children [10.50 vs. 11.18 cm2 (P <0.001, respectively]. Conclusion The UFA in children aged 7-12 months is smaller in stunted than in non-stunted children, whereas UMA in children aged 7-12 months and 13-24 months was smaller in stunted compared to non-stunted children.

  18. Motion of a carrier with a mobile load along a rough inclined plane

    Science.gov (United States)

    Bilchenko, G. G.

    2018-03-01

    The mechanical system consisting of a carrier and a load is considered. The load can move respectively the carrier according to the preset given motion law. The carrier motion from rest caused the load motion is investigated. The carrier can move translationally along rectilinear trajectory along rough inclined plane. The trajectory is the line of the greatest descent. The axis of rectilinear channel along which the load moves is situated in vertical plane containing the carrier trajectory. The Coulomb model is taken to describe the friction forces on sloped plane. Differential equations of motion of carrier with load are obtained. The sufficient condition of the carrier motion without detachment from inclined plane is given. For two special cases of the channel installation angle and the plane inclination angle combination the motion types are described. The computation experiments results are presented: the carrier motions in the special cases are illustrated, the phase portraits for some types of motions are constructed.

  19. Subcutaneous administration of carrier erythrocytes: slow release of entrapped agent

    International Nuclear Information System (INIS)

    DeLoach, J.R.; Corrier, D.E.

    1988-01-01

    Carrier erythrocytes administered subcutaneously in mice release encapsulated molecules at the injection site and through cells that escape the injection site. One day postinjection, the efflux of encapsulated [ 14 C]sucrose, [ 3 H]inulin, and 51 Cr-hemoglobin from the injection site was 45, 55, and 65%, respectively. Intact carrier erythrocytes escaped the injection site and entered the blood circulation carrying with them the encapsulated molecules. Most of the encapsulated [ 3 H]inulin that reached whole blood circulated within erythrocytes. Small but measurable numbers of encapsulated molecules were trapped within lymph nodes. Subcutaneous injection of carrier erythrocytes may allow for limited extravascular tissue targeting of drugs

  20. Lack of neural compensatory mechanisms of BDNF val66met met carriers and APOE E4 carriers in healthy aging, mild cognitive impairment, and Alzheimer's disease.

    Science.gov (United States)

    Gomar, Jesus J; Conejero-Goldberg, Concepcion; Huey, Edward D; Davies, Peter; Goldberg, Terry E

    2016-03-01

    Compromises in compensatory neurobiologic mechanisms due to aging and/or genetic factors (i.e., APOE gene) may influence brain-derived neurotrophic factor (BDNF) val66met polymorphism effects on temporal lobe morphometry and memory performance. We studied 2 cohorts from Alzheimer's Disease Neuroimaging Initiative: 175 healthy subjects and 222 with prodromal and established Alzheimer's disease. Yearly structural magnetic resonance imaging and cognitive performance assessments were carried out over 3 years of follow-up. Both cohorts had similar BDNF Val/Val and Met allele carriers' (including both Val/Met and Met/Met individuals) distribution. In healthy subjects, a significant trend for thinner posterior cingulate and precuneus cortices was detected in Met carriers compared to Val homozygotes in APOE E4 carriers, with large and medium effect sizes, respectively. The mild cognitive impairment/Alzheimer's disease cohort showed a longitudinal decline in entorhinal thickness in BDNF Met carriers compared to Val/Val in APOE E4 carriers, with effect sizes ranging from medium to large. In addition, an effect of BDNF genotype was found in APOE E4 carriers for episodic memory (logical memory and ADAS-Cog) and semantic fluency measures, with Met carriers performing worse in all cases. These findings suggest a lack of compensatory mechanisms in BDNF Met carriers and APOE E4 carriers in healthy and pathological aging. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Thermal activation of carriers from semiconductor quantum wells

    International Nuclear Information System (INIS)

    Johnston, M.B.; Herz, L.M.; Dao, L.V.; Gal, M.; Tan, H.H.; Jagadish, C.

    1999-01-01

    Full text: We have conducted a systematic investigation of the thermal excitation of carriers in confined states of quantum wells. Carriers may be injected into a sample containing a quantum well electrically or optically, once there they rapidly thermalise and are captured by the confined state of the quantum well. Typically electrons and holes recombine radiatively from their respective quantum well states. As a quantum well sample is heated from low temperatures (∼10K), phonon interactions increase which leads to carriers being excited from the well region into the higher energy, barrier region of the sample. Since carrier recombination from barrier regions is via non-radiative processes, there is strong temperature dependence of photoluminescence from the quantum well region. We measured quantum well photoluminescence as a function of excitation intensity and wavelength over the temperature range from 8K to 300K. In high quality InGaAs quantum wells we found unexpected intensity dependence of the spectrally integrated temperature dependent photoluminescence. We believe that this is evidence for by the existence of saturable states at the interfaces of the quantum wells

  2. Validation of the Microlife WatchBP Home blood pressure device in pregnancy for medium and large arm circumferences.

    Science.gov (United States)

    Clark, Katherine; Snowball, Olivia; Nzelu, Diane; Kay, Polly; Kametas, Nikos A

    2018-06-01

    The Microlife WatchBP Home automated blood pressure device was assessed for accuracy in pregnant women of medium (arm circumference. The British Hypertension Society validation protocol was modified for the purpose of this study to include women with arm circumference of less than 32 cm (N=51) and greater than or equal to 32 cm (N=46) as two separate arms. The device achieved an overall A/A grade for medium arm circumference and B/A grade for large arm circumference. The mean±SD device-observer difference was 1.7±6.2 and -0.4±4.4 for systolic and diastolic blood pressure, respectively, for medium arm circumference and 3.0±8.5 and 1.5±5.1, respectively, for large arm circumference. When all women with pre-eclampsia from both groups were pooled (N=23), the device achieved an overall grade of A/A with mean differences of 2.1±7.2 for systolic blood pressure and 1.0±5.6 for diastolic blood pressure. The Microlife WatchBP Home automated blood pressure device can be recommended for use in pregnant women of all gestations, including those with pre-eclampsia. However, caution is needed for women with large arm circumferences.

  3. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Luo-Luo, E-mail: jiangluoluo@gmail.com [College of Physics and Electronic Information Engineering, Wenzhou University, Wenzhou 325035 (China); College of Physics and Technology, Guangxi Normal University, Guilin, Guangxi 541004 (China); Wang, Wen-Xu [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Beijing Normal University, Beijing 100875 (China); Lai, Ying-Cheng [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Arizona State University, Tempe, AZ 85287 (United States); Ni, Xuan [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States)

    2012-07-09

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  4. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    International Nuclear Information System (INIS)

    Jiang, Luo-Luo; Wang, Wen-Xu; Lai, Ying-Cheng; Ni, Xuan

    2012-01-01

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  5. Armed conflict and child health.

    Science.gov (United States)

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health throughout the world. One in six children worldwide lives in an area of armed conflict and civilians are more likely to die than soldiers as a result of the conflict. In stark contrast to the effect on children, the international arms trade results in huge profits for the large corporations involved in producing arms, weapons and munitions. Armed conflict is not inevitable but is an important health issue that should be prevented.

  6. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  7. Low temperature carrier transport properties in isotopically controlled germanium

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Kohei [Univ. of California, Berkeley, CA (United States)

    1994-12-01

    Investigations of electronic and optical properties of semiconductors often require specimens with extremely homogeneous dopant distributions and precisely controlled net-carrier concentrations and compensation ratios. The previous difficulties in fabricating such samples are overcome as reported in this thesis by growing high-purity Ge single crystals of controlled 75Ge and 70Ge isotopic compositions, and doping these crystals by the neutron transmutation doping (NTD) technique. The resulting net-impurity concentrations and the compensation ratios are precisely determined by the thermal neutron fluence and the [74Ge]/[70Ge] ratios of the starting Ge materials, respectively. This method also guarantees unprecedented doping uniformity. Using such samples the authors have conducted four types of electron (hole) transport studies probing the nature of (1) free carrier scattering by neutral impurities, (2) free carrier scattering by ionized impurities, (3) low temperature hopping conduction, and (4) free carrier transport in samples close to the metal-insulator transition.

  8. Hydrodynamic characteristics of airlift nitrifying reactor using carrier-induced granular sludge

    International Nuclear Information System (INIS)

    Jin Rencun; Zheng Ping; Mahmood, Qaisar; Zhang Lei

    2008-01-01

    Since nitrification is the rate-limiting step in the biological nitrogen removal from wastewater, many studies have been conducted on the immobilization of nitrifying bacteria. A laboratory-scale investigation was carried out to scrutinize the effectiveness of activated carbon carrier addition for granulation of nitrifying sludge in a continuous-flow airlift bioreactor and to study the hydrodynamics of the reactor with carrier-induced granules. The results showed that the granular sludge began to appear and matured 60 and 108 days, respectively, after addition of carriers, while no granule was observed in the absence of carriers in the control test. The mature granules had a diameter of 0.5-5 mm (1.6 mm in average), settling velocity 22.3-55.8 m h -1 and specific gravity of 1.086. The relationship between the two important hydrodynamic coefficients, i.e. gas holdup and liquid circulation velocity, and the superficial gas velocity were established by a simple model and were confirmed experimentally. The model also could predict the critical superficial gas velocity for liquid circulation and that for granules circulation, with respective values of 1.017 and 2.662 cm min -1 , accurately

  9. Hydrodynamic characteristics of airlift nitrifying reactor using carrier-induced granular sludge

    Energy Technology Data Exchange (ETDEWEB)

    Jin Rencun [Department of Environmental Engineering, Zhejiang University, Hangzhou 310029 (China); Department of Environmental Science, Hangzhou Normal University, Hangzhou 310036 (China); Zheng Ping [Department of Environmental Engineering, Zhejiang University, Hangzhou 310029 (China)], E-mail: pzheng@zju.edu.cn; Mahmood, Qaisar; Zhang Lei [Department of Environmental Engineering, Zhejiang University, Hangzhou 310029 (China)

    2008-09-15

    Since nitrification is the rate-limiting step in the biological nitrogen removal from wastewater, many studies have been conducted on the immobilization of nitrifying bacteria. A laboratory-scale investigation was carried out to scrutinize the effectiveness of activated carbon carrier addition for granulation of nitrifying sludge in a continuous-flow airlift bioreactor and to study the hydrodynamics of the reactor with carrier-induced granules. The results showed that the granular sludge began to appear and matured 60 and 108 days, respectively, after addition of carriers, while no granule was observed in the absence of carriers in the control test. The mature granules had a diameter of 0.5-5 mm (1.6 mm in average), settling velocity 22.3-55.8 m h{sup -1} and specific gravity of 1.086. The relationship between the two important hydrodynamic coefficients, i.e. gas holdup and liquid circulation velocity, and the superficial gas velocity were established by a simple model and were confirmed experimentally. The model also could predict the critical superficial gas velocity for liquid circulation and that for granules circulation, with respective values of 1.017 and 2.662 cm min{sup -1}, accurately.

  10. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.

    Science.gov (United States)

    Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang

    2017-01-01

    MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  11. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application

    Directory of Open Access Journals (Sweden)

    Chao-Yu Pan

    2017-01-01

    Full Text Available MicroRNAs (miRNAs play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  12. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  13. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  14. Armed conflict and child health

    OpenAIRE

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health\\ud throughout the world. One in six children worldwide lives\\ud in an area of armed conflict and civilians are more likely\\ud to die than soldiers as a result of the conflict. In stark\\ud contrast to the effect on children, the international arms\\ud trade results in huge profits for the large corporations\\ud involved in producing arms, weapons and munitions.\\ud Armed conflict is not inevitable but is an important\\ud health issue that should be...

  15. Low-complexity Joint Sub-carrier Phase Noise Compensation for Digital Multi-carrier Systems

    DEFF Research Database (Denmark)

    Yankov, Metodi Plamenov; Barletta, Luca; Zibar, Darko

    2017-01-01

    Joint sub-carrier phase noise processing is proposed which recovers the SNR penalty related to decreased sub-carrier baudrate w.r.t. single carrier systems. The method enables digital sub-banding to be safely employed for nonlinear mitigation for modulation formats of up to 256-QAM.......Joint sub-carrier phase noise processing is proposed which recovers the SNR penalty related to decreased sub-carrier baudrate w.r.t. single carrier systems. The method enables digital sub-banding to be safely employed for nonlinear mitigation for modulation formats of up to 256-QAM....

  16. [Hand-arm vibration syndrome in caisson miners].

    Science.gov (United States)

    Kákosy, T; Németh, L; Hazay, B; Posgay, M; Diner, J

    1997-07-06

    Authors examined 43 caisson-miners with symptoms of the upper extremities because of suspicion of hand-arm vibration syndrome. Also vibration measurements were performed on the pneumatic hammer used by the workers. The acceleration of the vibration exceeded 2.5-3.5 times the maximum allowable level according to the ISO 5349. Symptoms and signs of hand-arm vibration syndrome were found in 39 cases (90.7%). The vascular, peripheral neurological and locomotor system of the upper extremities were affected in similar frequency: 54.8; 51.6 and 51.2%, respectively. The most common angiological alteration was the Raynaud's phenomenon. Neurologically predominated the tunnel syndromes. Among the osteoarticular lesions the degenerative phenomena were the most frequent. In most cases more than one pathological alteration occurred. Fatigue fracture of the spinous process of vertebra D. I. appeared in one single case, degenerative changes of cervical spine in 34 patients (79.1%). The very common occurrence of the locomotor alterations and tunnel syndromes respectively can be explained probably also by the high physical stress required by this profession. The detailed examination of the locomotor system is very important by the periodical screening of the caisson-miners.

  17. Carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool

    International Nuclear Information System (INIS)

    Cai, Yu; Sha, Shuang

    2016-01-01

    This paper proposes a new carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool used in a cylindrical borehole environment during oil-based mud drilling processes. The new tool is an orthogonal frequency division multiplexing access-based contactless multi-measurand detection tool. The tool can measure formation resistivity in different azimuthal angles and elevational depths. It can measure many more measurands simultaneously in a specified bandwidth than the legacy frequency division multiplexing multi-measurand tool without a channel-select filter while avoiding inter-carrier interference. The paper also shows that formation resistivity is not sensitive to frequency in certain frequency bands. The average resistivity collected from N subcarriers can increase the measurement of the signal-to-noise ratio (SNR) by N times given no amplitude clipping in the current-injection electrode. If the clipping limit is taken into account, with the phase rotation of each single carrier, the amplitude peak-to-average ratio can be reduced by 3 times, and the SNR can achieve a 9/ N times gain over the single-carrier system. The carrier-interleaving technique is also introduced to counter the carrier frequency offset (CFO) effect, where the CFO will cause inter-pad interference. A qualitative analysis and simulations demonstrate that block-interleaving performs better than tone-interleaving when coping with a large CFO. The theoretical analysis also suggests that increasing the subcarrier number can increase the measurement speed or enhance elevational resolution without sacrificing receiver performance. The complex orthogonal multi-pad multi-carrier resistivity logging tool, in which all subcarriers are complex signals, can provide a larger available subcarrier pool than other types of transceivers. (paper)

  18. Effects of age, sex and arm on the precision of arm position sense—left-arm superiority in healthy right-handers

    OpenAIRE

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally th...

  19. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  20. Design of a multi-arm randomized clinical trial with no control arm.

    Science.gov (United States)

    Magaret, Amalia; Angus, Derek C; Adhikari, Neill K J; Banura, Patrick; Kissoon, Niranjan; Lawler, James V; Jacob, Shevin T

    2016-01-01

    Clinical trial designs that include multiple treatments are currently limited to those that perform pairwise comparisons of each investigational treatment to a single control. However, there are settings, such as the recent Ebola outbreak, in which no treatment has been demonstrated to be effective; and therefore, no standard of care exists which would serve as an appropriate control. For illustrative purposes, we focused on the care of patients presenting in austere settings with critically ill 'sepsis-like' syndromes. Our approach involves a novel algorithm for comparing mortality among arms without requiring a single fixed control. The algorithm allows poorly-performing arms to be dropped during interim analyses. Consequently, the study may be completed earlier than planned. We used simulation to determine operating characteristics for the trial and to estimate the required sample size. We present a potential study design targeting a minimal effect size of a 23% relative reduction in mortality between any pair of arms. Using estimated power and spurious significance rates from the simulated scenarios, we show that such a trial would require 2550 participants. Over a range of scenarios, our study has 80 to 99% power to select the optimal treatment. Using a fixed control design, if the control arm is least efficacious, 640 subjects would be enrolled into the least efficacious arm, while our algorithm would enroll between 170 and 430. This simulation method can be easily extended to other settings or other binary outcomes. Early dropping of arms is efficient and ethical when conducting clinical trials with multiple arms. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  2. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available   Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  3. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  4. CLASSIFICATION OF SOURCES ON HISTORY OF ARMED CONFLICT IN CHECHEN REPUBLIC IN LATE 20 TH CENTURY

    Directory of Open Access Journals (Sweden)

    Николай Николаевич Малишевский

    2014-12-01

    Full Text Available The article deals with the problems of historiography of the armed conflict in the Chechen Republic. The analysis enabled to classify available sources on this subject by the functional-specific criterion -a source and a data carrier, that is the way of its fixing, comprising three principal types of sources: written (text, cartographical and audiovisual. The information potential of available sources on the armed conflict history in Chechen Republic is not limited to certain subjects and promotes disclosing of such aspects of the conflict as: - stages (the first campaign, the second campaign, the counterterrorism operation; - opposition methods (active and passive; - opposition forms (collective and individual; - system of military-political management of territory; - scale and intensity of clashes; - a complex of actions of the state peace-making policy and feature of its realization; - specificity of participation of separate groups of the population; - regional aspect of events (on the scale of separate settlement, area etc. - conflict history in persons; - problems of the thematic literature.

  5. Preimplantation genetic diagnosis outcomes and meiotic segregation analysis of robertsonian translocation carriers.

    Science.gov (United States)

    Ko, Duck Sung; Cho, Jae Won; Lee, Hyoung-Song; Kim, Jin Yeong; Kang, Inn Soo; Yang, Kwang Moon; Lim, Chun Kyu

    2013-04-01

    To investigate the meiotic segregation patterns of cleavage-stage embryos from robertsonian translocation carriers and aneuploidy of chromosome 18 according to meiotic segregation patterns. Retrospective study. Infertility center and laboratory of reproductive biology and infertility. Sixty-two couples with robertsonian translocation carriers. One blastomere was biopsied from embryos and diagnosed with the use of fluorescence in situ hybridization (FISH). Translocation chromosomes were analyzed with the use of locus-specific and subtelomeric FISH probes. Aneuploidy of chromosome 18 was assessed simultaneously with translocation chromosomes. Preimplantation genetic diagnosis (PGD) outcomes, meiotic segregation patterns of robertsonian translocation, and aneuploidy of chromosome 18 depending on meiotic segregation patterns. Two hundred seventy embryos of 332 transferrable embryos were transferred in 113 cycles, and 27 healthy babies were born. The alternate segregation was significantly higher in male carriers than in female carriers (43.9% vs. 29.9%, respectively), and adjacent segregation was higher in female carriers than in male carriers (44.7% vs. 38.7%, respectively). Aneuploidy of chromosome 18 was significantly increased in 3:0-segregated or chaotic embryos. Forty-seven alternate embryos were excluded from embryo replacement owing to aneuploidy of chromosome 18. In carriers of robertsonian translocation, meiotic segregation showed differences between men and women. Frequent meiotic errors caused by premature predivision or nondisjunction and less stringent checkpoint in women might cause such differences between sexes. Aneuploidy of chromosome 18 might be influenced by meiotic segregation of translocation chromosomes. Factors that cause malsegregation, such as 3:0 or chaotic segregation, seem to play a role in aneuploidy of chromosome 18. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Arms control and disarmament

    International Nuclear Information System (INIS)

    Acton, P.

    1992-01-01

    Article VI of the Non-Proliferation Treaty commits each party to work towards nuclear disarmament and to negotiations to stop the nuclear arms race. All parties to the Treaty are included and a wide range of arms control and disarmament issues are covered. However the main focus at Treaty review conferences has been on nuclear disarmament by the nuclear weapon states which are party to the Treaty. This has led to bilateral United States - Soviet Union negotiations resulting in the Intermediate-range Nuclear Forces Treaty in December 1987 and the Strategic Arms Reduction Treaty (START) in July followed by unilateral arms control measures in September and October 1991. (UK)

  7. D-α-tocopherol polyethylene glycol succinate-based derivative nanoparticles as a novel carrier for paclitaxel delivery

    Directory of Open Access Journals (Sweden)

    Wu YP

    2015-08-01

    Full Text Available Yupei Wu,1,* Qian Chu,2,* Songwei Tan,1 Xiangting Zhuang,1 Yuling Bao,1 Tingting Wu,1 Zhiping Zhang1,3,41Tongji School of Pharmacy, 2Department of Oncology, Tongji Hospital, Tongji Medical School, 3Hubei Engineering Research Center for NDDS, 4National Engineering Research Center for Nanomedicine, Huazhong University of Science and Technology, Wuhan, People’s Republic of China*These authors contributed equally to this workAbstract: Paclitaxel (PTX is one of the most effective antineoplastic drugs. Its current clinical administration Taxol® is formulated in Cremophor EL, which causes serious side effects. Nanoparticles (NP with lower systemic toxicity and enhanced therapeutic efficiency may be an alternative formulation of the Cremophor EL-based vehicle for PTX delivery. In this study, novel amphipathic 4-arm-PEG-TPGS derivatives, the conjugation of D-α-tocopherol polyethylene glycol succinate (TPGS and 4-arm-polyethylene glycol (4-arm-PEG with different molecular weights, have been successfully synthesized and used as carriers for the delivery of PTX. These 4-arm-PEG-TPGS derivatives were able to self-assemble to form uniform NP with PTX encapsulation. Among them, 4-arm-PEG5K-TPGS NP exhibited the smallest particle size, highest drug-loading efficiency, negligible hemolysis rate, and high physiologic stability. Therefore, it was chosen for further in vitro and in vivo investigations. Facilitated by the effective uptake of the NP, the PTX-loaded 4-arm-PEG5K-TPGS NP showed greater cytotoxicity compared with free PTX against human ovarian cancer (A2780, non-small cell lung cancer (A549, and breast adenocarcinoma cancer (MCF-7 cells, as well as a higher apoptotic rate and a more significant cell cycle arrest effect at the G2/M phase in A2780 cells. More importantly, PTX-loaded 4-arm-PEG5K-TPGS NP resulted in a significantly improved tumor growth inhibitory effect in comparison to Taxol® in S180 sarcoma-bearing mice models. This study suggested

  8. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  9. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  10. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Science.gov (United States)

    2010-01-01

    ... forth in paragraph (c) of this section. In such cases the Board may determine in an adjudicatory... carrier shall not engage in joint public relations activities at points served by both carriers which tend... either carrier are performed in common with the other carrier or as part of a single system. In cases...

  11. CO(J = 2 - 1) study of molecular clouds in the southwest arm of M31

    International Nuclear Information System (INIS)

    Kutner, M.L.; Verter, F.; Rickard, L.J.

    1990-01-01

    The first map of M31 in the CO(J = 2 - 1) transition, covering a 3 arcmin by 3 arcmin section of the SW arm-interarm region, is presented. The CO spectra in the arm region defined by H II regions are characterized by strong, narrow features which are interpreted here to be giant molecular clouds with masses of a few 100,000 solar masses. The interarm emission is interpreted as an ensemble of small clouds with masses of a few 10,000 solar masses. On the arm about 70 percent of the emission comes from large clouds, while off the arm essentially all of it comes from small clouds. The mass surface density on this section of M31 is about that of a comparable section of the Scutum arm of the Galaxy. The velocities of the giant clouds in the arm are shifted with respect to the rest of the molecular and atomic gas by about 15 km/s. This may be due to cloud response to passage through the spiral arm potential. 49 refs

  12. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  13. Both Hemophilia Health Care Providers and Hemophilia A Carriers Report that Carriers have Excessive Bleeding

    Science.gov (United States)

    Paroskie, Allison; Oso, Olatunde; DeBaun, Michael R.; Sidonio, Robert F

    2014-01-01

    Introduction Hemophilia A, the result of reduced factor VIII (FVIII) activity, is an X-linked recessive bleeding disorder. Previous reports of Hemophilia A carriers suggest an increased bleeding tendency. Our objective was to determine the attitudes and understanding of the Hemophilia A carrier bleeding phenotype, and opinions regarding timing of carrier testing from the perspective of both medical providers and affected patients. Data from this survey was used as preliminary data for an ongoing prospective study. Material and Methods An electronic survey was distributed to physicians and nurses employed at Hemophilia Treatment Centers (HTC), and Hemophilia A carriers who were members of Hemophilia Federation of America. Questions focused on the clinical understanding of bleeding symptoms and management of Hemophilia A carriers, and the timing and intensity of carrier testing. Results Our survey indicates that 51% (36/51) of providers compared to 78% (36/46) of carriers believe that Hemophilia A carriers with normal FVIII activity have an increased bleeding tendency (pHemophilia A carriers report a high frequency of bleeding symptoms. Regarding carrier testing, 72% (50/69) of medical providers recommend testing after 14 years of age, conversely 65% (29/45) of Hemophilia A carriers prefer testing to be done prior to this age (pHemophilia A carriers self-report a higher frequency of bleeding than previously acknowledged, and have a preference for earlier testing to confirm carrier status. PMID:24309601

  14. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  15. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  16. Nonparetic arm force does not overinhibit the paretic arm in chronic poststroke hemiparesis.

    Science.gov (United States)

    Dimyan, Michael A; Perez, Monica A; Auh, Sungyoung; Tarula, Erick; Wilson, Matthew; Cohen, Leonardo G

    2014-05-01

    To determine whether nonparetic arm force overinhibits the paretic arm in patients with chronic unilateral poststroke hemiparesis. Case-control neurophysiological and behavioral study of patients with chronic stroke. Research institution. Eighty-six referred patients were screened to enroll 9 participants (N=9) with a >6 month history of 1 unilateral ischemic infarct that resulted in arm hemiparesis with residual ability to produce 1Nm of wrist flexion torque and without contraindication to transcranial magnetic stimulation. Eight age- and handedness-matched healthy volunteers without neurologic diagnosis were studied for comparison. Not applicable. Change in interhemispheric inhibition targeting the ipsilesional primary motor cortex (M1) during nonparetic arm force. We hypothesized that interhemispheric inhibition would increase more in healthy controls than in patients with hemiparesis. Healthy age-matched controls had significantly greater increases in inhibition from their active to resting M1 than patients with stroke from their active contralesional to resting ipsilesional M1 in the same scenario (20%±7% vs -1%±4%, F1,12=6.61, P=.025). Patients with greater increases in contralesional to ipsilesional inhibition were better performers on the 9-hole peg test of paretic arm function. Our findings reveal that producing force with the nonparetic arm does not necessarily overinhibit the paretic arm. Though our study is limited in generalizability by the small sample size, we found that greater active contralesional to resting ipsilesional M1 inhibition was related with better recovery in this subset of patients with chronic poststroke. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Technique improvement of thoracoabdominal CT scan for patients with arm-raising disability

    International Nuclear Information System (INIS)

    Yuan Zhidong; Liu Yuanjian; Jiang Guoyin; Feng Fei; Wang Chenglin; Liu Pengcheng

    2010-01-01

    Objective: To explore a new scanning technique to reduce and avoid image artifacts of thoracoabdominal CT and improve image quality for patients who cannot raise their arms. Methods: Sixty-one patients with arm-raising disability between March 2004 and May 2009 were enrolled in the study. Thirty-one cases before June 2007 were scanned with their arms beside their body (control group), 30 cases after June 2007 were scanned with their arms shifting to different imaging planes of the spine (study group), and another 30 patients who can raising their arms were taken as routine group. The images artifacts were blindly evaluated by 5-points scale (severe, less severe, moderate, minimum and no artifact) by 2 experienced CT technologists and one radiologist and compared between the three groups (X 2 test). CT values and its noise of the liver with or without artifact of the three groups were measured and analyzed by one-way ANOVA test. Results: In the control group, 11 cases had severe, 15 cases had less severe, 5 cases had moderate. In the study group, 6 cases had moderate, 15 cases had minimum, 9 cases had no artifact. In the routine group, 8 cases minimum and 22 cases had no artifact. Image quality was significantly improved in the study group compared to the conventional group where X 2 =95.32 and P<0.01. CT value and the noise of the liver without artifact were (54.5 ± 3.0) HU and 10.7 ± 2.4 in the control group, (52.0 ± 3.5) HU and 10.7 ± 0.5 in the study group, (53.7 ± 3.1) HU and 9.9 ± 0.5 in the routine group, respectively. CT value and noise of the liver with artifact were (41.7 ± 8.4) HU and 17.9 ± 2.6 in control group, (53.1 ± 6.9) HU and 11.0 ± 0.7 in the study group, (54.1 ± 2.4) HU and 9.9 ± 0.5 in the routine group, respectively. The CT value and its noise variation with artifact were significantly higher in the control group than the study group and the control group, where F=36.352, 235.848, respectively and P<0.01. Conclusion: The image

  18. Consistency of blood pressure differences between the left and right arms.

    Science.gov (United States)

    Eguchi, Kazuo; Yacoub, Mona; Jhalani, Juhee; Gerin, William; Schwartz, Joseph E; Pickering, Thomas G

    2007-02-26

    It is unclear to what extent interarm blood pressure (BP) differences are reproducible vs the result of random error. The present study was designed to resolve this issue. We enrolled 147 consecutive patients from a hypertension clinic. Three sets of 3 BP readings were recorded, first using 2 oscillometric devices simultaneously in the 2 arms (set 1); next, 3 readings were taken sequentially for each arm using a standard mercury sphygmomanometer (set 2); finally, the readings as performed for set 1 were repeated (set 3). The protocol was repeated at a second visit for 91 patients. Large interarm systolic BP differences were consistently seen in 2 patients with obstructive arterial disease. In the remaining patients, the systolic BP and the diastolic BP, respectively, were slightly higher in the right arm than in the left arm by 2 to 3 mm Hg and by 1 mm Hg for all 3 sets (Pdifference of more than 5 mm Hg were 11 (7.5%) and 4 (2.7%) across all 3 sets of readings. Among patients who repeated the test, none had a consistent interarm BP difference of more than 5 mm Hg across the 2 visits. The interarm BP difference was consistent only when obstructive arterial disease was present. Although BP in the right arm tended to be higher than in the left arm, clinically meaningful interarm differences were not reproducible in the absence of obstructive arterial disease and are attributable to random variation.

  19. Nature of galaxy spiral arms

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1984-01-01

    The nature of galaxy spiral arms is discussed in a popular form. Two approaches in the theory of spiral arms are considered; they are related to the problem of differential galaxy rotation and the spiral structure wave theory. The example of Galaxy M31 is considered to compare the structural peculiarity of its spiral arms with the wave theory predictions. The situation in the central and south-eastern part of arm S4 in Galaxy M31 noted to be completely explained by the wave theory and modern concepts on the origin of massive stars

  20. Arms races between and within species.

    Science.gov (United States)

    Dawkins, R; Krebs, J R

    1979-09-21

    An adaptation in one lineage (e.g. predators) may change the selection pressure on another lineage (e.g. prey), giving rise to a counter-adaptation. If this occurs reciprocally, an unstable runaway escalation or 'arms race' may result. We discuss various factors which might give one side an advantage in an arms race. For example, a lineage under strong selection may out-evolve a weakly selected one (' the life-dinner principle'). We then classify arms races in two independent ways. They may be symmetric or asymmetric, and they may be interspecific or intraspecific. Our example of an asymmetric interspecific arms race is that between brood parasites and their hosts. The arms race concept may help to reduce the mystery of why cuckoo hosts are so good at detecting cuckoo eggs, but so bad at detecting cuckoo nestlings. The evolutionary contest between queen and worker ants over relative parental investment is a good example of an intraspecific asymmetric arms race. Such cases raise special problems because the participants share the same gene pool. Interspecific symmetric arms races are unlikely to be important, because competitors tend to diverge rather than escalate competitive adaptations. Intraspecific symmetric arms races, exemplified by adaptations for male-male competition, may underlie Cope's Rule and even the extinction of lineages. Finally we consider ways in which arms races can end. One lineage may drive the other to extinction; one may reach an optimum, thereby preventing the other from doing so; a particularly interesting possibility, exemplified by flower-bee coevolution, is that both sides may reach a mutual local optimum; lastly, arms races may have no stable and but may cycle continuously. We do not wish necessarily to suggest that all, or even most, evolutionary change results from arms races, but we do suggest that the arms race concept may help to resolve three long-standing questions in evolutionary theory.

  1. JPRS Report Arms Control

    National Research Council Canada - National Science Library

    1993-01-01

    Table of Contents: (1) COMMONWEALTH OF INDEPENDENT STATES - (A) GENERAL Flaws in U.S.-Russian SSD Agreement Viewed, Khariton - Espionage Not Crucial in Soviet Nuclear Arms Development, Further on Espionage Role in Nuclear Arms Projects...

  2. Enhancement of charge carrier recombination efficiency by utilizing a hole-blocking interlayer in white OLEDs

    International Nuclear Information System (INIS)

    Wang Qi; Yu Junsheng; Zhao Juan; Li Ming; Lu Zhiyun

    2013-01-01

    Charge carrier balance and recombination are essential factors relating to the performance of white organic light-emitting devices (WOLEDs). In this study, we discussed the contribution of charge carrier balance in the interlayer-based WOLEDs. By varying the interlayer thickness, the mechanisms of electroluminescent spectral alteration, energy transfer, and especially, charge carrier transport and balance in the devices were investigated and revealed in detail. With a 5 nm thick interlayer tailoring charge carrier transport and recombination, WOLEDs yielded a high power efficiency, current efficiency and external quantum efficiency of 36.1 lm W −1 , 47.1 cd A −1 and 18.3%, respectively. Additionally, single-carrier devices and quantitative analysis were subsequently carried out, demonstrating that the enhancement of carrier recombination efficiency corresponds to the optimization of device performance. (paper)

  3. Organization of octopus arm movements: a model system for studying the control of flexible arms.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Yarom, Y; Fiorito, G; Segev, I; Hochner, B

    1996-11-15

    Octopus arm movements provide an extreme example of controlled movements of a flexible arm with virtually unlimited degrees of freedom. This study aims to identify general principles in the organization of these movements. Video records of the movements of Octopus vulgaris performing the task of reaching toward a target were studied. The octopus extends its arm toward the target by a wave-like propagation of a bend that travels from the base of the arm toward the tip. Similar bend propagation is seen in other octopus arm movements, such as locomotion and searching. The kinematics (position and velocity) of the midpoint of the bend in three-dimensional space were extracted using the direct linear transformation algorithm. This showed that the bend tends to move within a single linear plane in a simple, slightly curved path connecting the center of the animal's body with the target location. Approximately 70% of the reaching movements demonstrated a stereotyped tangential velocity profile. An invariant profile was observed when movements were normalized for velocity and distance. Two arms, extended together in the same behavioral context, demonstrated identical velocity profiles. The stereotyped features of the movements were also observed in spontaneous arm extensions (not toward an external target). The simple and stereotypic appearance of the bend trajectory suggests that the position of the bend in space and time is the controlled variable. We propose that this strategy reduces the immense redundancy of the octopus arm movements and hence simplifies motor control.

  4. Effect of flocculation on performance of arming yeast in direct ethanol fermentation

    Energy Technology Data Exchange (ETDEWEB)

    Khaw Teik Seong; Katakura, Yoshio; Ninomiya, Kazuaki; Shioya, Suteaki [Osaka Univ. (Japan). Dept. of Biotechnology; Bito, Yohei; Katahira, Satoshi; Kondo, Akihiko [Kobe Univ. (Japan). Dept. of Chemical Science and Engineering; Ueda, Mitsuyoshi [Kyoto Univ. (Japan). Div. of Applied Life Sciences

    2006-11-15

    In the direct ethanol fermentation of raw starch by arming yeast with {alpha}-amylase and glucoamylase, it is preferable to use a flocculent yeast because it can be recovered without centrifugation. Three types of arming yeast system, I (nonflocculent), II (mildly flocculent), and III (heavily flocculent), were constructed and their fermentation performances were compared. With an increase in the degree of flocculation, specific ethanol production rate for soluble starch decreased (0.19, 0.17, and 0.12 g g-dry-cell{sup -1} h{sup -1} for systems I, II, and III, respectively), but that for raw starch did not decrease as much as expected (0.06, 0.06, and 0.04 g g-dry-cell{sup -1} h{sup -1} for systems I, II and III, respectively). Microscopic observation revealed that many starch granules were captured in the yeast flocs in system III during the direct ethanol fermentation of raw starch. It was suggested that the capture of starch granules increases apparent substrate concentration for amylolytic enzymes in arming yeast cell flocs; thus, the specific ethanol production rate of system III was kept at a level comparable to those of the other systems. (orig.)

  5. Charge carrier relaxation model in disordered organic semiconductors

    International Nuclear Information System (INIS)

    Lu, Nianduan; Li, Ling; Sun, Pengxiao; Liu, Ming

    2013-01-01

    The relaxation phenomena of charge carrier in disordered organic semiconductors have been demonstrated and investigated theoretically. An analytical model describing the charge carrier relaxation is proposed based on the pure hopping transport theory. The relation between the material disorder, electric field and temperature and the relaxation phenomena has been discussed in detail, respectively. The calculated results reveal that the increase of electric field and temperature can promote the relaxation effect in disordered organic semiconductors, while the increase of material disorder will weaken the relaxation. The proposed model can explain well the stretched-exponential law by adopting the appropriate parameters. The calculation shows a good agreement with the experimental data for organic semiconductors

  6. Algorithms for Unequal-Arm Michelson Interferometers

    Science.gov (United States)

    Giampieri, Giacomo; Hellings, Ronald W.; Tinto, Massimo; Bender, Peter L.; Faller, James E.

    1994-01-01

    A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

  7. Sealed substrate carrier for electroplating

    Science.gov (United States)

    Ganti, Kalyana Bhargava [Fremont, CA

    2012-07-17

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier includes a non-conductive carrier body on which the substrates are held, and conductive lines are embedded within the carrier body. A conductive bus bar is embedded into a top side of the carrier body and is conductively coupled to the conductive lines. A thermoplastic overmold covers a portion of the bus bar, and there is a plastic-to-plastic bond between the thermoplastic overmold and the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

  8. FY1995 development of artificial arm 'SMART ARM' by spherical ultrasonic motor; 1995 nendo kyumen choonpa motor wo mochiita jinko gishu smart arm no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project has an intention of development of new type artificial arm by spherical ultrasonic motor. We have succeeded in developing new type of spherical ultrasonic motor with three DOF. And we have succeeded in applying the motor to an artificial arm. This arm have advantages of small size, low weight torque comparing with conventional ones. We demonstrated them the new arm behaved well and it had good controlabilty. (NEDO)

  9. Carrier-carrier relaxation kinetics in quantum well semiconductor structures with nonparabolic energy bands

    DEFF Research Database (Denmark)

    Dery, H.; Tromborg, Bjarne; Eisenstein, G.

    2003-01-01

    We describe carrier-carrier scattering dynamics in an inverted quantum well structure including the nonparabolic nature of the valance band. A solution of the semiconductor Bloch equations yields strong evidence to a large change in the temporal evolution of the carrier distributions compared to ...

  10. Ground reaction forces produced by two different hockey skating arm swing techniques.

    Science.gov (United States)

    Hayward-Ellis, Julie; Alexander, Marion J L; Glazebrook, Cheryl M; Leiter, Jeff

    2017-10-01

    The arm swing in hockey skating can have a positive effect on the forces produced by each skate, and the resulting velocity from each push off. The main purpose of this study was to measure the differences in ground reaction forces (GRFs) produced from an anteroposterior versus a mediolateral style hockey skating arm swing. Twenty-four elite-level female hockey players performed each technique while standing on a ground-mounted force platform, and all trials were filmed using two video cameras. Force data was assessed for peak scaled GRFs in the frontal and sagittal planes, and resultant GRF magnitude and direction. Upper limb kinematics were assessed from the video using Dartfish video analysis software, confirming that the subjects successfully performed two distinct arm swing techniques. The mediolateral arm swing used a mean of 18.38° of glenohumeral flexion/extension and 183.68° of glenohumeral abduction/adduction while the anteroposterior technique used 214.17° and 28.97° respectively. The results of this study confirmed that the mediolateral arm swing produced 37% greater frontal plane and 33% less sagittal plane GRFs than the anteroposterior arm swing. The magnitudes of the resultant GRFs were not significantly different between the two techniques; however, the mediolateral technique produced a resultant GRF with a significantly larger angle from the direction of travel (44.44°) as compared to the anteroposterior technique (31.60°). The results of this study suggest that the direction of GRFs produced by the mediolateral arm swing more closely mimic the direction of lower limb propulsion during the skating stride.

  11. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  12. 29 CFR 1201.1 - Carrier.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Carrier. 1201.1 Section 1201.1 Labor Regulations Relating to Labor (Continued) NATIONAL MEDIATION BOARD DEFINITIONS § 1201.1 Carrier. The term carrier includes any express company, sleeping car company, carrier by railroad, subject to the Interstate Commerce Act...

  13. A joint recovery scheme for carrier frequency offset and carrier phase noise using extended Kalman filter

    Science.gov (United States)

    Li, Linqian; Feng, Yiqiao; Zhang, Wenbo; Cui, Nan; Xu, Hengying; Tang, Xianfeng; Xi, Lixia; Zhang, Xiaoguang

    2017-07-01

    A joint carrier recovery scheme for polarization division multiplexing (PDM) coherent optical transmission system is proposed and demonstrated, in which the extended Kalman filter (EKF) is exploited to estimate and equalize the carrier frequency offset (CFO) and carrier phase noise (CPN) simultaneously. The proposed method is implemented and verified in the PDM-QPSK system and the PDM-16QAM system with the comparisons to conventional improved Mth-power (IMP) algorithm for CFO estimation, blind phase search (BPS) algorithm or Viterbi-Viterbi (V-V) algorithm for CPN recovery. It is demonstrated that the proposed scheme shows high CFO estimation accuracy, with absolute mean estimation error below 1.5 MHz. Meanwhile, the proposed method has the CFO tolerance of [±3 GHz] for PDM-QPSK system and [±0.9 GHz] for PDM-16QAM system. Compare with IMP/BPS and IMP/V-V, the proposed scheme can enhance the linewidth symbol duration product from 3 × 10-4 (IMP/BPS) and 2 × 10-4 (IMP/V-V) to 1 × 10-3 for PDM-QPSK, and from 1 × 10-4 (IMP/BPS) to 3 × 10-4 for PDM-16QAM, respectively, at the 1 dB optical signal-to-noise ratio (OSNR) penalty. The proposed Kalman filter also shows a fast convergence with only 100 symbols and much lower computational complexity.

  14. Improvements in Neck and Arm Pain Following an Anterior Cervical Discectomy and Fusion.

    Science.gov (United States)

    Massel, Dustin H; Mayo, Benjamin C; Bohl, Daniel D; Narain, Ankur S; Hijji, Fady Y; Fineberg, Steven J; Louie, Philip K; Basques, Bryce A; Long, William W; Modi, Krishna D; Singh, Kern

    2017-07-15

    A retrospective analysis. The aim of this study was to quantify improvements in Visual Analogue Scale (VAS) neck and arm pain, Neck Disability Index (NDI), and Short Form-12 (SF-12) Mental (MCS) and Physical (PCS) Composite scores following an anterior cervical discectomy and fusion (ACDF). ACDF is evaluated with patient-reported outcomes. However, the extent to which these outcomes improve following ACDF remains poorly defined. A surgical registry of patients who underwent primary, one- or two-level ACDF during 2013 to 2015 was reviewed. Comparisons of VAS neck and arm, NDI, and SF-12 MCS and PCS scores were performed using paired t tests from preoperative to each postoperative time point. Analysis of variance (ANOVA) was used to estimate the reduction in neck and arm pain over the first postoperative year. Subgroup analyses were performed for patients with predominant neck (pNP) or arm (pAP) pain, as well as for one- versus two-level ACDF. Eighty-nine patients were identified. VAS neck and arm, NDI, and SF-12 PCS improved from preoperative scores at all postoperative time points (P pain (P pain over the first 6 months and 12 weeks postoperatively, respectively (P pain and 55.1% reduction in arm pain over the first postoperative year (P pain following ACDF regardless of presenting symptom. In addition, patients undergoing one-level ACDF report greater reductions in neck and arm pain than patients undergoing two-level fusion. 4.

  15. Differential Analysis of the Nasal Microbiome of Pig Carriers or Non-Carriers of Staphylococcus aureus

    DEFF Research Database (Denmark)

    Espinosa-Gongora, Carmen; Larsen, Niels; Schonning, Kristian

    2016-01-01

    pathogen in animal carriers. The aim of this study was to determine whether the nasal microbiome of pig S. aureus carriers differs from that of non-carriers. The V3-V5 region of the 16S rRNA gene was sequenced from nasal swabs of 44 S. aureus carriers and 56 non-carriers using the 454 GS FLX titanium...... microbiome of pigs that are not colonized with S. aureus harbours several species/taxa that are significantly less abundant in pig carriers, suggesting that the nasal microbiota may play a role in the individual predisposition to S. aureus nasal carriage in pigs. Further research is warranted to isolate...

  16. Estimation of Human Arm Joints Using Two Wireless Sensors in Robotic Rehabilitation Tasks

    Directory of Open Access Journals (Sweden)

    Arturo Bertomeu-Motos

    2015-12-01

    Full Text Available This paper presents a novel kinematic reconstruction of the human arm chain with five degrees of freedom and the estimation of the shoulder location during rehabilitation therapy assisted by end-effector robotic devices. This algorithm is based on the pseudoinverse of the Jacobian through the acceleration of the upper arm, measured using an accelerometer, and the orientation of the shoulder, estimated with a magnetic angular rate and gravity (MARG device. The results show a high accuracy in terms of arm joints and shoulder movement with respect to the real arm measured through an optoelectronic system. Furthermore, the range of motion (ROM of 50 healthy subjects is studied from two different trials, one trying to avoid shoulder movements and the second one forcing them. Moreover, the shoulder movement in the second trial is also estimated accurately. Besides the fact that the posture of the patient can be corrected during the exercise, the therapist could use the presented algorithm as an objective assessment tool. In conclusion, the joints’ estimation enables a better adjustment of the therapy, taking into account the needs of the patient, and consequently, the arm motion improves faster.

  17. Personality traits in Huntington's disease: An exploratory study of gene expansion carriers and non-carriers.

    Science.gov (United States)

    Larsen, Ida Unmack; Mortensen, Erik Lykke; Vinther-Jensen, Tua; Nielsen, Jørgen Erik; Knudsen, Gitte Moos; Vogel, Asmus

    2016-12-01

    Huntington's disease (HD) is associated with risk for developing psychiatric symptoms. Vulnerability or resilience to psychiatric symptoms may be associated with personality traits. This exploratory study, aimed to investigate personality traits in a large cohort of HD carriers and at risk gene-expansion negative individuals (HD non-carriers), exploring whether carrying the HD gene or growing up in an HD family influences personality traits. Forty-seven HD carriers, Thirty-nine HD non-carriers, and 121 healthy controls answered the Danish version of the revised NEO personality inventory. Comparisons between HD carriers and HD non-carriers were mostly non-significant but the combined group of HD carriers and non-carriers showed significantly higher scores on the facets: "hostility," "assertiveness," and "activity" and on the trait "Conscientiousness" relative to controls, "Conscientiousness" have been associated with resilience to psychiatric symptoms. Twelve HD carriers and non-carriers were classified as depressed and showed significantly lower scores on "Extraversion" and "Conscientiousness" and significantly higher scores on "Neuroticism," which are associated with vulnerability to psychiatric symptoms. Our findings suggest that, there is no direct effect of the HD gene on personality traits, but that personality assessment may be relevant to use when identifying individuals from HD families who are vulnerable to develop psychiatric symptoms. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Security and arms control

    International Nuclear Information System (INIS)

    Kolodziej, E.A.; Morgan, P.M.

    1989-01-01

    This book attempts to clarify and define selected current issues and problems related to security and arms control from an international perspective. The chapters are organized under the following headings. Conflict and the international system, Nuclear deterrence, Conventional warfare, Subconventional conflict, Arms control and crisis management

  19. Ultra light inspection robotic arm, design and modeling

    International Nuclear Information System (INIS)

    Voisembert, S.

    2012-01-01

    One of the major challenges in robotics is the improvement of inspections operations in confined and hazardous area using unmanned remote handling systems. Articulated arm are used in this case to carry some diagnostic tools for the inspection tasks. These long reach multi-link carriers should be characterized by a large workspace and reduced mass. Today, with about ten degrees of freedom and ten meters long they have reached their performance limit. Indeed, for long reach, the arm should have enough torque to carry its own weight plus the payload in cantilever mode and enough stiffness to minimize the deflection caused by the gravity. Despite the use of best materials and components, this kind of robot has reach its performance limit. Overcoming this limit needs a change in paradigm. Therefore a problem-solving, analysis and forecasting tool TRIZ (theory of inventive problem solving) is used. It leads naturally to identify the origin of the dilemma: the proper weight of the arm and so its mass under gravity. In particular, it proposes to postulate that a no-mass robot exists. An analysis of the properties of such a robot leads to the patented concept of an ultra light inflatable robot with unique and constant volume and constant diameter joints. This new object would benefit from advantages such as easy implementation, harmlessness toward its environment and so the ability to lean on it without damage. Therefore it could easily increase its range and its foreseen low-cost building would open a wide field of new applications. This thesis work, elaborates appropriate technical concepts and dimensioning methods for ultra light inflatable robots. The payload and length performances of an inflatable robot are analytically validated. Experimentations and a finite-element modeling are used for a pre-dimensioning of the joints and different modes of construction are prototyped in partnership with, specialized company in thigh-tech textile. The joints are also modeled with

  20. Peptide-Carrier Conjugation

    DEFF Research Database (Denmark)

    Hansen, Paul Robert

    2015-01-01

    To produce antibodies against synthetic peptides it is necessary to couple them to a protein carrier. This chapter provides a nonspecialist overview of peptide-carrier conjugation. Furthermore, a protocol for coupling cysteine-containing peptides to bovine serum albumin is outlined....

  1. Version of the galaxy spiral structure model with opposite-directed arms and inter-arm links

    Energy Technology Data Exchange (ETDEWEB)

    Dolidze, M V [AN Gruzinskoj SSR, Abastumani. Abastumanskaya Astrofizicheskaya Observatoriya

    1963-05-01

    An attempt is made to explain some peculiarities of the local spiral structure and large-scale distribution of HII regions in the Galaxy by coexistence of the trailing and leading arm systems of different power and development. The existence of opposite-directed arms and inter-arm links in the circular zone (5-15 kpc) is analysed from the point of view of different Galaxy models.

  2. Differences and effects of medium and large adult cuffs on blood pressure readings in individuals with muscular arms.

    Science.gov (United States)

    Fonseca-Reyes, Salvador; Fajardo-Flores, Ismael; Montes-Casillas, Mayra; Forsyth-Macquarrie, Avril

    2009-08-01

    This study analyzed systolic and diastolic blood pressure (SBP and DBP) reading differences in individuals with muscular arms, using medium and large adult cuffs. Resting blood pressures (BPs) were measured in bodybuilders competing at the Mexican National Bodybuilding and Fitness Championship. The means of two bilateral simultaneous arm BP measurements were obtained using two different cuff sizes, 12 cm (medium adult) and 16 cm (large adult). A total of 193 bodybuilders completed the measurements. With an arm circumference greater than 33 cm, the SBP and DBP average taken with the medium adult cuff was higher than that obtained with the large adult cuff, 8.2+/-10.6 and 1.6+/-7.4 mmHg, respectively; however, a significant difference was observed only with the SBP. With the medium adult cuff, 48 of 144 individuals showed SBP at least 140 mmHg, whereas with the large adult cuff there were only 17 of 144 individuals. In those participants with an arm circumference less than 33 cm, the BP was nonsignificantly lower with the large cuff, -4.24+/-9.2 and -2.24+/-5.4 mmHg for the SBP and DBP, respectively. Incorrect cuffing of a muscular arm leads to significant errors in the measurement of SBP and DBP, similar to that observed in miscuffing of nonmuscular arms.

  3. Spiral-arm instability: giant clump formation via fragmentation of a galactic spiral arm

    Science.gov (United States)

    Inoue, Shigeki; Yoshida, Naoki

    2018-03-01

    Fragmentation of a spiral arm is thought to drive the formation of giant clumps in galaxies. Using linear perturbation analysis for self-gravitating spiral arms, we derive an instability parameter and define the conditions for clump formation. We extend our analysis to multicomponent systems that consist of gas and stars in an external potential. We then perform numerical simulations of isolated disc galaxies with isothermal gas, and compare the results with the prediction of our analytic model. Our model describes accurately the evolution of the spiral arms in our simulations, even when spiral arms dynamically interact with one another. We show that most of the giant clumps formed in the simulated disc galaxies satisfy the instability condition. The clump masses predicted by our model are in agreement with the simulation results, but the growth time-scale of unstable perturbations is overestimated by a factor of a few. We also apply our instability analysis to derive scaling relations of clump properties. The expected scaling relation between the clump size, velocity dispersion, and circular velocity is slightly different from that given by the Toomre instability analyses, but neither is inconsistent with currently available observations. We argue that the spiral-arm instability is a viable formation mechanism of giant clumps in gas-rich disc galaxies.

  4. Poly(glycolide multi-arm star polymers: Improved solubility via limited arm length

    Directory of Open Access Journals (Sweden)

    Florian K. Wolf

    2010-06-01

    Full Text Available Due to the low solubility of poly(glycolic acid (PGA, its use is generally limited to the synthesis of random copolyesters with other hydroxy acids, such as lactic acid, or to applications that permit direct processing from the polymer melt. Insolubility is generally observed for PGA when the degree of polymerization exceeds 20. Here we present a strategy that allows the preparation of PGA-based multi-arm structures which significantly exceed the molecular weight of processable oligomeric linear PGA (<1000 g/mol. This was achieved by the use of a multifunctional hyperbranched polyglycerol (PG macroinitiator and the tin(II-2-ethylhexanoate catalyzed ring-opening polymerization of glycolide in the melt. With this strategy it is possible to combine high molecular weight with good molecular weight control (up to 16,000 g/mol, PDI = 1.4–1.7, resulting in PGA multi-arm star block copolymers containing more than 90 wt % GA. The successful linkage of PGA arms and PG core via this core first/grafting from strategy was confirmed by detailed NMR and SEC characterization. Various PG/glycolide ratios were employed to vary the length of the PGA arms. Besides fluorinated solvents, the materials were soluble in DMF and DMSO up to an average arm length of 12 glycolic acid units. Reduction in the Tg and the melting temperature compared to the homopolymer PGA should lead to simplified processing conditions. The findings contribute to broadening the range of biomedical applications of PGA.

  5. 7 CFR 35.4 - Carrier.

    Science.gov (United States)

    2010-01-01

    ... AND PLUMS Definitions § 35.4 Carrier. Carrier means any common or private carrier, including, but not being limited to, trucks, rail, airplanes, vessels, tramp or chartered steamers, whether carrying for...

  6. Ultrafast carrier dynamics in a p-type GaN wafer under different carrier distributions

    Science.gov (United States)

    Fang, Yu; Yang, Junyi; Yang, Yong; Wu, Xingzhi; Xiao, Zhengguo; Zhou, Feng; Song, Yinglin

    2016-02-01

    The dependence of the carrier distribution on photoexcited carrier dynamics in a p-type Mg-doped GaN (GaN:Mg) wafer were systematically measured by femtosecond transient absorption (TA) spectroscopy. The homogeneity of the carrier distribution was modified by tuning the wavelength of the UV pulse excitation around the band gap of GaN:Mg. The TA kinetics appeared to be biexponential for all carrier distributions, and only the slower component decayed faster as the inhomogeneity of the carrier distribution increased. It was concluded that the faster component (50-70 ps) corresponded to the trap process of holes by the Mg acceptors, and the slower component (150-600 ps) corresponded to the combination of non-radiative surface recombination and intrinsic carrier recombination via dislocations. Moreover, the slower component increased gradually with the incident fluence due to the saturation of surface states.

  7. Hot carrier degradation in semiconductor devices

    CERN Document Server

    2015-01-01

    This book provides readers with a variety of tools to address the challenges posed by hot carrier degradation, one of today’s most complicated reliability issues in semiconductor devices.  Coverage includes an explanation of carrier transport within devices and book-keeping of how they acquire energy (“become hot”), interaction of an ensemble of colder and hotter carriers with defect precursors, which eventually leads to the creation of a defect, and a description of how these defects interact with the device, degrading its performance. • Describes the intricacies of hot carrier degradation in modern semiconductor technologies; • Covers the entire hot carrier degradation phenomenon, including topics such as characterization, carrier transport, carrier-defect interaction, technological impact, circuit impact, etc.; • Enables detailed understanding of carrier transport, interaction of the carrier ensemble with the defect precursors, and an accurate assessment of how the newly created defects imp...

  8. Maintainable substrate carrier for electroplating

    Science.gov (United States)

    Chen, Chen-An [Milpitas, CA; Abas, Emmanuel Chua [Laguna, PH; Divino, Edmundo Anida [Cavite, PH; Ermita, Jake Randal G [Laguna, PH; Capulong, Jose Francisco S [Laguna, PH; Castillo, Arnold Villamor [Batangas, PH; Ma,; Xiaobing, Diana [Saratoga, CA

    2012-07-17

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.

  9. A study of mid-arm and chest circumferences as predictors of low birthweight.

    Science.gov (United States)

    Rogo, K; Nyagudi, O; Ferguson, A

    1991-02-01

    Nine hundred ninety-nine newborns were examined in order to determine the relationship between birthweight and mid-arm and chest circumstances. An early neonatal mortality rate of 51/1000 was recorded, being much higher for preterm (301/1000) than term babies (2.5/1000). Both mid-arm and chest circumference showed highly significant correlations with birthweight (r = 0.872, P less than 0.0001 and r = 0.918, P less than 0.0001, respectively). The correlation between weight and chest circumstances was upheld even for very small babies.

  10. Non-permeable substrate carrier for electroplating

    Science.gov (United States)

    Abas, Emmanuel Chua; Chen, Chen-An; Ma, Diana Xiaobing; Ganti, Kalyana Bhargava

    2012-11-27

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

  11. Mitochondrial glutamate carriers from Drosophila melanogaster: biochemical, evolutionary and modeling studies.

    Science.gov (United States)

    Lunetti, Paola; Cappello, Anna Rita; Marsano, René Massimiliano; Pierri, Ciro Leonardo; Carrisi, Chiara; Martello, Emanuela; Caggese, Corrado; Dolce, Vincenza; Capobianco, Loredana

    2013-10-01

    The mitochondrial carriers are members of a family of transport proteins that mediate solute transport across the inner mitochondrial membrane. Two isoforms of the glutamate carriers, GC1 and GC2 (encoded by the SLC25A22 and SLC25A18 genes, respectively), have been identified in humans. Two independent mutations in SLC25A22 are associated with severe epileptic encephalopathy. In the present study we show that two genes (CG18347 and CG12201) phylogenetically related to the human GC encoding genes are present in the D. melanogaster genome. We have functionally characterized the proteins encoded by CG18347 and CG12201, designated as DmGC1p and DmGC2p respectively, by overexpression in Escherichia coli and reconstitution into liposomes. Their transport properties demonstrate that DmGC1p and DmGC2p both catalyze the transport of glutamate across the inner mitochondrial membrane. Computational approaches have been used in order to highlight residues of DmGC1p and DmGC2p involved in substrate binding. Furthermore, gene expression analysis during development and in various adult tissues reveals that CG18347 is ubiquitously expressed in all examined D. melanogaster tissues, while the expression of CG12201 is strongly testis-biased. Finally, we identified mitochondrial glutamate carrier orthologs in 49 eukaryotic species in order to attempt the reconstruction of the evolutionary history of the glutamate carrier function. Comparison of the exon/intron structure and other key features of the analyzed orthologs suggests that eukaryotic glutamate carrier genes descend from an intron-rich ancestral gene already present in the common ancestor of lineages that diverged as early as bilateria and radiata. © 2013.

  12. Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.

    Science.gov (United States)

    Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao

    2016-06-01

    Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, 25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.

  13. Coordinated Resolved Motion Control of Dual-Arm Manipulators with Closed Chain

    Directory of Open Access Journals (Sweden)

    Tianliang Liu

    2016-05-01

    Full Text Available When applied to some tasks, such as payload handling, assembling, repairing and so on, the two arms of a humanoid robot will form a closed kinematic chain. It makes the motion planning and control for dual-arm coordination very complex and difficult. In this paper, we present three types of resolved motion control methods for a humanoid robot during coordinated manipulation. They are, respectively, position-level, velocity-level and acceleration-level resolved motion control methods. The desired pose, velocity and acceleration of each end-effector are then resolved according to the desired motion of the payload and the constraints on the closed-chain system without consideration of the internal force. Corresponding to the three cases above, the joint variables of each arm are then calculated using the inverse kinematic equations, at position-level, velocity-level or acceleration-level. Finally, a dynamic modelling and simulation platform is established based on ADAMS and Matlab software. The proposed methods are verified by typical cases. The simulation results show that the proposed control strategy can realize the dual-arm coordinated operation and the internal force of the closed chain during the operation is controlled in a reasonable range at the same time.

  14. Modernization of African Armed Forces

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa.......Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa....

  15. Studies on low-carrier radiofluorination of non-active aromatics with no-carrier-added [18F]fluoride

    International Nuclear Information System (INIS)

    Cardinale, Jens

    2013-01-01

    In vivo imaging with positron emission tomography generally demands radiotracers with a high specific activity. In case of fluorine-18 the required no-carrier-added (n.c.a.) starting material is only available in form of fluoride. This and the short half-life of 109.7 minutes of the radionuclide lead to the demand of special methods for radiosyntheses. The only practical procedure for manufacturing n.c.a. [ 18 F]fluoro-compounds is therefore nucleophilic substitution. There is, however, still a lack of effective procedures for the labelling of electron rich aromatic molecules starting from n.c.a. [ 18 F]fluoride. A process for n.c.a. radiofluorination of these compounds is offered by the reaction of iodonium compounds as starting materials. In this study modern procedures for the synthesis of iodoniumsalts and -ylides were investigated. Several precursor molecules for the versatile synthetic building block 4-[ 18 F]fluoroiodobenzene were synthesised. In this course, a new one-pot procedure for the synthesis of iodoniumylides was developed. Further on, the syntheses of suitable iodonium precursors for two fluorophenoxy-derivatives, which are possible antidepressants, were investigated. Due to their binding profile these compounds can be considered as ligands for the serotonin reuptake transporter (SERT) and the norepinephrin reuptake transporter (NET), respectively. The preparation of appropriate iodonium salts proved to be too problematic, while the synthesis of suitable iodoniumylides could be accomplished with satisfactory yields of about 30% and 40 %, respectively. Both compounds were labelled with n.c.a. [ 18 F]fluoride and deprotected to the desired target compounds 4-((3-[ 18 F]fluorophenoxy)(phenyl)methyl)piperidine and 4-((4-[ 18 F]fluorophenoxy)(phenyl)methyl)piperidine in radiochemical yields of about 40 % and 25 %, respectively. Those are now available for preclinical evaluation studies. Furthermore, a process for the palladium catalysed synthesis of 18

  16. Strong carrier localization in stacking faults in semipolar (11-22) GaN

    Science.gov (United States)

    Okur, Serdal; Monavarian, Morteza; Das, Saikat; Izyumskaya, Natalia; Zhang, Fan; Avrutin, Vitaliy; Morkoç, Hadis; Özgür, Ümit

    2015-03-01

    The effects of stacking faults (SFs) on optical processes in epitaxially grown semipolar (1122) GaN on m-sapphire substrate have been investigated in detail using steady-state photoluminescence (PL) and time- and polarization-resolved PL. We demonstrate that the carrier recombination dynamics are substantially influenced due to strong carrier localization in the stacking faults. In addition to nonradiative recombination, carrier trapping/detrapping and carrier transfer between the stacking faults and donors are also found to be among the mechanisms affecting the recombination dynamics at different temperatures. PL decay times of both I1-type BSF and 3.31 eV SF (E-type BSF or prismatic stacking fault) do not show temperature dependence up to 80 K while 3.31 eV SF exhibits longer PL decay times (~3 ns) at low temperatures as compared to I1-type BSF (~1 ns), indicative of lower efficiency for radiative recombination. After 80 K, PL decay times decreased by power of ~-1 and ~-2 for 3.31 eV SF and I1-type BSF, respectively. It is obtained from radiative decay times with respect to temperature that the carrier localization becomes higher in I1-type BSF compared to 3.31 eV SF increasing the temperature. I1-type BSF also shows higher PL intensity, which is attributed to larger density, and therefore, larger contribution to recombination dynamics as compared to other type of stacking faults. Polarization-resolved PL measurements also revealed that the degree of polarization for the I1-type BSF (0.30) was twice that for the 3.31 eV SF.

  17. A Suboptimal Power-Saving Transmission Scheme in Multiple Component Carrier Networks

    Science.gov (United States)

    Chung, Yao-Liang; Tsai, Zsehong

    Power consumption due to transmissions in base stations (BSs) has been a major contributor to communication-related CO2 emissions. A power optimization model is developed in this study with respect to radio resource allocation and activation in a multiple Component Carrier (CC) environment. We formulate and solve the power-minimization problem of the BS transceivers for multiple-CC networks with carrier aggregation, while maintaining the overall system and respective users' utilities above minimum levels. The optimized power consumption based on this model can be viewed as a lower bound of that of other algorithms employed in practice. A suboptimal scheme with low computation complexity is proposed. Numerical results show that the power consumption of our scheme is much better than that of the conventional one in which all CCs are always active, if both schemes maintain the same required utilities.

  18. 21 CFR 890.3640 - Arm sling.

    Science.gov (United States)

    2010-04-01

    ... arm sling is a device intended for medical purposes to immobilize the arm, by means of a fabric band... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arm sling. 890.3640 Section 890.3640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  19. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  20. ARM assembly language with hardware experiments

    CERN Document Server

    Elahi, Ata

    2015-01-01

    This book provides a hands-on approach to learning ARM assembly language with the use of a TI microcontroller. The book starts with an introduction to computer architecture and then discusses number systems and digital logic. The text covers ARM Assembly Language, ARM Cortex Architecture and its components, and Hardware Experiments using TILM3S1968. Written for those interested in learning embedded programming using an ARM Microcontroller. ·         Introduces number systems and signal transmission methods   ·         Reviews logic gates, registers, multiplexers, decoders and memory   ·         Provides an overview and examples of ARM instruction set   ·         Uses using Keil development tools for writing and debugging ARM assembly language Programs   ·         Hardware experiments using a Mbed NXP LPC1768 microcontroller; including General Purpose Input/Output (GPIO) configuration, real time clock configuration, binary input to 7-segment display, creating ...

  1. Limitation and reduction of conventional arms

    International Nuclear Information System (INIS)

    Chervov, N.

    1989-01-01

    We are living at a time when war between East and West---not only nuclear but also conventional war--- is totally senseless. It cannot solve any problem---political, economic, or other. From the military point of view, war between East and West is madness. Calculations show that after 20 days of conventional warfare Europe could become another Hiroshima. Therefore we must work out forms of long-term cooperation. Before it is too late, we must radically reduce our military potentials and rethink our military doctrines. The reduction by 500,000 men is for the USSR no simple solution. But that step may become a model for further actions by East and West. The West's proposal that armed forces should be reduced to the level of 95 percent of NATO's armed forces is not a solution. Both sides---the Warsaw Treaty Organization and NATO---must be deprived of the capacity to launch a sudden attack; they must be deprived of their attack potential. The USSR initiative shows the true way toward that goal. What is happening in connection with our decision is not always correctly interpreted in the West, and so I should like to draw attention to some distinctive features of the Soviet armed forces reductions and, first of all, their scale (equivalent to the Bundeswehr of the Federal Republic of Germany). With respect to Europe, Soviet troops are to be reduced in the German Democratic Republic, Czechoslovakia, Hungary, Poland, and the European part of the Soviet Union---a total of 240,000 men, 10,000 tanks, 9,500 artillery systems, and 800 combat aircraft

  2. PHENIX Muon Arms

    International Nuclear Information System (INIS)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En'yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F.; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D.; Sondheim, W.E.; Sorensen, S.; Staley, F.; Stankus, P.W.; Steffens, S.; Stein, E.M.; Stepanov, M.; Stokes, W.; Sugioka, M.; Sun, Z.; Taketani, A.; Taniguchi, E.; Tepe, J.D.; Thornton, G.W.; Tian, W.; Tojo, J.; Torii, H.; Towell, R.S.; Tradeski, J.; Vassent, M.; Velissaris, C.; Villatte, L.; Wan, Y.; Watanabe, Y.; Watkins, L.C.; Whitus, B.R.; Williams, C.; Willis, P.S.; Wong-Swanson, B.G.; Yang, Y.; Yoneyama, S.; Young, G.R.; Zhou, S.

    2003-01-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons (∼10 -3 ). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described

  3. PHENIX Muon Arms

    Energy Technology Data Exchange (ETDEWEB)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En' yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F. E-mail: readkf@ornl.gov; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D. [and others

    2003-03-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons ({approx}10{sup -3}). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described.

  4. Association between intramuscular fat in the arm following arm training and INSIG2

    DEFF Research Database (Denmark)

    Popadic Gacesa, J Z; Secher, N H; Momcilovic, M

    2014-01-01

    ) ; mean ± standard deviation) carried out a 12-week two-arm elbow extensor training (10 maximal extensions with 1 min recovery between bouts) five times per day, five times per week. For 17 volunteers, upper arm muscle and adipose tissue [subcutaneous (SCAT) and intramuscular (IMAT)] volumes were.......0 ± 0.9%; GC/CC: %IMAT 0.6 ± 0.5% (P > 0.05). However, in the year following the training, accumulation of upper arm IMAT was twice as large in participants homozygous for the G allele (GG: Δ%IMAT +2.5 ± 0.8%; GC/CC: Δ%IMAT +1.1 ± 0.7%; P 

  5. [Study on the movement of the carrier recombination region in organic light-emitting diodes (OLEDs) based on DPVBi/Alq3].

    Science.gov (United States)

    Yan, Guang; Zhao, Su-ling; Xu, Zheng; Zhang, Fu-jun; Kong, Chao; Liu, Xiao-dong; Gong, Wei; Gao, Li-yan

    2011-07-01

    Series of organic light emitting devices with basic structure of ITO/PCBM: PVK(x Wt%, approximately 40 nm)/DPVBi(30 nm)/Alq3 (30 nm)/Al were fabricated in order to investigate the carrier recombination region movement in these devices. The carrier injection-dependent, the carrier transport-dependent and the voltage-dependent carrier recombination region movements were investigated respectively by modifying cathode with lithium fluoride, by changing the doping concentration of PCBM and by changing the voltage on the devices. The physical mechanism behind the voltage-dependent carrier recombination region movement was discussed.

  6. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  7. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  8. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  9. Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Anna W.; Satyshur, Kenneth A.; Morales, Neydis Moreno; Forest, Katrina T. (UW)

    2016-02-01

    ABSTRACT

    Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulator (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRRmon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems.

  10. How does a planet excite multiple spiral arms?

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-01-01

    Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.

  11. Large enhancements of thermopower and carrier mobility in quantum dot engineered bulk semiconductors.

    Science.gov (United States)

    Liu, Yuanfeng; Sahoo, Pranati; Makongo, Julien P A; Zhou, Xiaoyuan; Kim, Sung-Joo; Chi, Hang; Uher, Ctirad; Pan, Xiaoqing; Poudeu, Pierre F P

    2013-05-22

    The thermopower (S) and electrical conductivity (σ) in conventional semiconductors are coupled adversely through the carriers' density (n) making it difficult to achieve meaningful simultaneous improvements in both electronic properties through doping and/or substitutional chemistry. Here, we demonstrate the effectiveness of coherently embedded full-Heusler (FH) quantum dots (QDs) in tailoring the density, mobility, and effective mass of charge carriers in the n-type Ti(0.1)Zr(0.9)NiSn half-Heusler matrix. We propose that the embedded FH QD forms a potential barrier at the interface with the matrix due to the offset of their conduction band minima. This potential barrier discriminates existing charge carriers from the conduction band of the matrix with respect to their relative energy leading to simultaneous large enhancements of the thermopower (up to 200%) and carrier mobility (up to 43%) of the resulting Ti(0.1)Zr(0.9)Ni(1+x)Sn nanocomposites. The improvement in S with increasing mole fraction of the FH-QDs arises from a drastic reduction (up to 250%) in the effective carrier density coupled with an increase in the carrier's effective mass (m*), whereas the surprising enhancement in the mobility (μ) is attributed to an increase in the carrier's relaxation time (τ). This strategy to manipulate the transport behavior of existing ensembles of charge carriers within a bulk semiconductor using QDs is very promising and could pave the way to a new generation of high figure of merit thermoelectric materials.

  12. Parity and the risk of breast and ovarian cancer in and mutation carriers

    OpenAIRE

    Milne , Roger L.; Osorio , Ana; Ramón Y Cajal , Teresa; Baiget , Montserrat; Lasa , Adriana; Diaz-Rubio , Eduardo; Hoya , Miguel; Caldés , Trinidad; Teulé , Alex; Lázaro , Conxi; Blanco , Ignacio; Balmaña , Judith; Sánchez-Ollé , Gessamí; Vega , Ana; Blanco , Ana

    2009-01-01

    Abstract Environmental or lifestyle factors are likely to explain part of the heterogeneity in breast and ovarian cancer risk among BRCA1 and BRCA2 mutation carriers. We assessed parity as a risk modifier in 515 and 503 Spanish female carriers of mutations in BRCA1 and BRCA2, respectively. Hazard ratios (HR) and their corresponding 95% confidence intervals (CI) were estimated using weighted Cox proportional hazards regression, adjusted for year of birth and study centre. The result...

  13. Inter-arm Differences in Simultaneous Blood Pressure Measurements in Ambulatory Patients without Cardiovascular Diseases.

    Science.gov (United States)

    Kim, Kyoung Bog; Oh, Mi Kyeong; Kim, Haa Gyoung; Ki, Ji Hoon; Lee, Soo Hee; Kim, Su Min

    2013-03-01

    It has traditionally been known that there is normally a difference in blood pressure (BP) between the two arms; there is at least 20 mm Hg difference in the systolic blood pressure (SBP) and 10 mm Hg difference in the diastolic blood pressure (DBP). However, recent epidemiologic studies have shown that there are between-arm differences of arm differences in simultaneous BP measurements obtained from ambulatory patients without cardiovascular diseases and to identify the factors associated these differences. We examined 464 patients who visited the outpatient clinic of Gangneung Asan Hospital clinical department. For the current analysis, we excluded patients with ischemic heart disease, stroke, arrhythmia, congestive heart failure, or hyperthyroidism. Simultaneous BP measurements were obtained using the Omron MX3 BP monitor in both arms. The inter-arm difference (IAD) in BP was expressed as the relative difference (right-arm BP [R] minus left-arm BP [L]: R - L) and the absolute difference (|R - L|). The mean absolute IAD in SBP and DBP were 3.19 ± 2.38 and 2.41 ± 1.59 mm Hg, respectively, in men and 2.61 ± 2.18 and 2.25 ± 2.01 mm Hg, respectively, in women. In men, there were 83.8% of patients with the IAD in SBP of ≤ 6 mm Hg, 98.1% with the IAD in SBP of ≤ 10 mm Hg, 96.5% with the IAD in DBP of ≤ 6 mm Hg and 0% with the IAD in DBP of > 10 mm Hg. In women, 89.6% of patients had IAD in SBP of ≤ 6 mm Hg, 92.1% with IAD in DBP of ≤ 6 mm Hg, and 0% with IAD in SBP of > 10 mm Hg or IAD in DBP of > 10 mm Hg. Gangneung Asan Hospital clinical series of patients showed that the absolute IAD in SBP had a significant correlation with cardiovascular risk factors such as the 10-year Framingham cardiac risk scores and higher BP in men and higher BP in women. However, the absolute IAD in SBP and DBP had no significant correlation with the age, obesity, smoking, drinking, hyperlipidemia, diabetes, metabolic syndrome, and renal function. Our results showed that there

  14. Managing new arms races

    International Nuclear Information System (INIS)

    Segal, G.

    1992-01-01

    The management of new arms races in the region of Asia-Pacific includes considerations of weapons trade and transfer in the region, with an emphasis on nuclear weapons proliferation. It deals with the problem of controlling the arms trade and the efforts to control conventional weapons and underlines the possible role and influence of Conference on Cooperation and Security in Europe (CSCE)

  15. 7 CFR 33.4 - Carrier.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Carrier. 33.4 Section 33.4 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... ISSUED UNDER AUTHORITY OF THE EXPORT APPLE ACT Definitions § 33.4 Carrier. Carrier means any common or...

  16. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  17. Low-cost carriers fare competition effect

    NARCIS (Netherlands)

    Carmona Benitez, R.B.; Lodewijks, G.

    2010-01-01

    This paper examines the effects that low-cost carriers (LCC’s) produce when entering new routes operated only by full-service carriers (FSC’s) and routes operated by low-cost carriers in competition with full-service carriers. A mathematical model has been developed to determine what routes should

  18. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    Science.gov (United States)

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  19. Estimating Motor Carrier Management Information System Crash File Underreporting from Carrier Records.

    Science.gov (United States)

    2017-08-01

    This FMCSA-sponsored research investigated the claim that motor carriers have a substantial number of crashes in their own records that are not contained in the Motor Carrier Management Information System (MCMIS) crash file. Based on the results of t...

  20. Initial results from NuSTAR observations of the Norma arm

    DEFF Research Database (Denmark)

    Bodaghee, Arash; Tomsick, John A.; Krivonos, Roman

    2014-01-01

    Results are presented for an initial survey of the Norma Arm gathered with the focusing hard X-ray telescope NuSTAR. The survey covers 0.2 deg2 of sky area in the 3-79 keV range with a minimum and maximum raw depth of 15 ks and 135 ks, respectively. Besides a bright black-hole X-ray binary...

  1. Incidence of and survival after subsequent cancers in carriers of pathogenic MMR variants with previous cancer

    DEFF Research Database (Denmark)

    Møller, Pål; Seppälä, Toni; Bernstein, Inge

    2017-01-01

    age 40 to age 70 years were 73% for pathogenic MLH1 (path_MLH1), 76% for path_MSH2 carriers and 52% for path_MSH6 carriers, and for colorectal cancer (CRC) the cumulative incidences were 46%, 48% and 23%, respectively. Crude survival after any subsequent cancer was 82% (95% CI 76% to 87%) and 10-year...

  2. Carrier transport uphill. I. General

    DEFF Research Database (Denmark)

    Rosenberg, T; Wilbrandt, W

    1963-01-01

    A quantitative treatment of a carrier pump operating with two carrier forms C and Z is presented. Asymmetric metabolic reactions are assumed to transform Z into C on one and C into Z on the other side of the membrane, establishing a carrier cycle. The kinetical consequences of this mechanism...

  3. Blood pressure measurement method and inter-arm differences: a meta-analysis.

    Science.gov (United States)

    Verberk, Willem J; Kessels, Alfons G H; Thien, Theo

    2011-11-01

    Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P arms, with one or two automatic devices and multiple readings should be taken.

  4. Next-generation DNA sequencing of HEXA: a step in the right direction for carrier screening

    Science.gov (United States)

    Hoffman, Jodi D; Greger, Valerie; Strovel, Erin T; Blitzer, Miriam G; Umbarger, Mark A; Kennedy, Caleb; Bishop, Brian; Saunders, Patrick; Porreca, Gregory J; Schienda, Jaclyn; Davie, Jocelyn; Hallam, Stephanie; Towne, Charles

    2013-01-01

    Tay-Sachs disease (TSD) is the prototype for ethnic-based carrier screening, with a carrier rate of ∼1/27 in Ashkenazi Jews and French Canadians. HexA enzyme analysis is the current gold standard for TSD carrier screening (detection rate ∼98%), but has technical limitations. We compared DNA analysis by next-generation DNA sequencing (NGS) plus an assay for the 7.6 kb deletion to enzyme analysis for TSD carrier screening using 74 samples collected from participants at a TSD family conference. Fifty-one of 74 participants had positive enzyme results (46 carriers, five late-onset Tay-Sachs [LOTS]), 16 had negative, and seven had inconclusive results. NGS + 7.6 kb del screening of HEXA found a pathogenic mutation, pseudoallele, or variant of unknown significance (VUS) in 100% of the enzyme-positive or obligate carrier/enzyme-inconclusive samples. NGS detected the B1 allele in two enzyme-negative obligate carriers. Our data indicate that NGS can be used as a TSD clinical carrier screening tool. We demonstrate that NGS can be superior in detecting TSD carriers compared to traditional enzyme and genotyping methodologies, which are limited by false-positive and false-negative results and ethnically focused, limited mutation panels, respectively, but is not ready for sole use due to lack of information regarding some VUS. PMID:24498621

  5. CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES

    International Nuclear Information System (INIS)

    Honig, Z. N.; Reid, M. J.

    2015-01-01

    We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiral arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others

  6. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  7. Solid lipid nanoparticles: A drug carrier system

    Directory of Open Access Journals (Sweden)

    Rashmi R Kokardekar

    2011-01-01

    Full Text Available Solid lipid nanoparticles (SLN are a type of nanoparticles. They are submicron colloidal carriers which are composed of physiological lipids, dispersed in water or in aqueous surfactant solutions. SLN have wide range of advantages over other types of nanoparticles. These include availability of large-scale production methods and no signs of cytotoxicity, which are main hindrances in the application of other types of nanoparticles. Hot and cold homogenization techniques are mainly employed for its production. They are mainly evaluated on the basis of their drug release profile and particle internal structure. The products based on SLN are under development. They have a very wide range of applications in cosmetics and pharmaceuticals. They can be applied for any purpose, for which nanoparticles have a distinct advantage. Thus, SLN can be used extensively as an alternative to the existing drug carrier systems, providing more flexibility with respect to the area of applications and also aspects for commercialization.

  8. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  9. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  10. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  11. Upper arm circumference measurement for detecting overweight and obesity in children aged 6-7 years

    Directory of Open Access Journals (Sweden)

    Dewi Rosariah Ayu

    2017-02-01

    Full Text Available Background Obesity is a worldwide problem and is associated with increased risk of metabolic syndrome. Nutritional status in children has traditionally been determined by body mass index (BMI scores, but with limitations. Upper arm circumference measurement may be a better predictor of energy, protein, and fat storage, as well as a simpler method for screening overweight and obesity in children. Objective To determine the diagnostic value of upper arm circumference compared to BMI for detecting overweight and obesity in children aged 6-7 years. Methods This diagnostic study with a cross-sectional design was performed from September to October 2015 at 16 primary schools in Palembang, Indonesia. We measured the heights, weights, and upper arm circumferences, and calculated BMIs of 2,258 children. Receiver-operator characteristic (ROC curve analysis was used to find an optimal upper arm circumference cut-off point to detect overweight and obesity. Diagnostic value was calculated by using a 2x2 table analysis. Results The prevalences of overweight and obesity were 5.8% and 11.7%, respectively. The optimal upper arm circumference cut-off points for detecting overweight in children aged 6-7 years was 185 mm (sensitivity 88.1% and specificity 78.3%, and for obesity was 195 mm (sensitivity 90.15% and specificity 86.65%. Upper arm circumference had a strong correlation with BMI. Conclusion Upper arm circumference measurement is an accurate method fordistinguishing between normoweight, overweight, and obesity in children aged 6-7 years.

  12. Electrothermal modeling, fabrication and analysis of low-power consumption thermal actuator with buckling arm

    KAUST Repository

    So, Hongyun; Pisano, Albert P.

    2013-01-01

    © 2013, Springer-Verlag Berlin Heidelberg. This paper reports on a novel thermal actuator with sub-micron metallic structures and a buckling arm to operate with low voltages and to generate very large deflections, respectively. A lumped

  13. Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography

    DEFF Research Database (Denmark)

    Claudius, C; Skovgaard, L T; Viby-Mogensen, J

    2010-01-01

    Studies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies...

  14. Joint Iterative Carrier Synchronization and Signal Detection for Dual Carrier 448 Gb/s PDM 16-QAM

    DEFF Research Database (Denmark)

    Zibar, Darko; Carvalho, Luis; Estaran Tolosa, Jose Manuel

    2013-01-01

    Soft decision driven joint carrier synchronization and signal detection, employing expectation maximization, is experimentally demonstrated. Employing soft decisions offers an improvement of 0.5 dB compared to hard decision digital PLL based carrier synchronization and demodulation.......Soft decision driven joint carrier synchronization and signal detection, employing expectation maximization, is experimentally demonstrated. Employing soft decisions offers an improvement of 0.5 dB compared to hard decision digital PLL based carrier synchronization and demodulation....

  15. Simultaneous transmission of wired and wireless signals based on double sideband carrier suppression

    Science.gov (United States)

    Bitew, Mekuanint Agegnehu; Shiu, Run-Kai; Peng, Peng-Chun; Wang, Cheng-Hao; Chen, Yan-Ming

    2017-11-01

    In this paper, we proposed and experimentally demonstrated simultaneous transmission of wired and wireless signals based on double sideband optical carrier suppression. By properly adjusting the bias point of the dual-output mach-zehnder modulator (MZM), a central carrier in one output port and a pair of first-order sidebands in another output port are generated. The pair of first-order sidebands are fed into a second MZM to generate second-order order sidebands. A wired signal is embedded on the central carrier while a wireless signal is embedded on the second-order sidebands. Unlike other schemes, we did not use optical filter to separate the carrier from the optical sidebands. The measured bit error rate (BER) and eye-diagrams after a 25 km single-mode-fiber (SMF) transmission proved that the proposed scheme is successful for both wired and wireless signals transmission. Moreover, the power penalty at the BER of 10-9 is 0.3 and 0.7 dB for wired and wireless signals, respectively.

  16. LIQUIFIED NATURAL GAS (LNG CARRIERS

    Directory of Open Access Journals (Sweden)

    Daniel Posavec

    2010-12-01

    Full Text Available Modern liquefied natural gas carriers are double-bottom ships classified according to the type of LNG tank. The tanks are specially designed to store natural gas cooled to -161°C, the boiling point of methane. Since LNG is highly flammable, special care must be taken when designing and operating the ship. The development of LNG carriers has begun in the middle of the twentieth century. LNG carrier storage space has gradually grown to the current maximum of 260000 m3. There are more than 300 LNG carriers currently in operation (the paper is published in Croatian.

  17. In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

    Science.gov (United States)

    Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.

    2013-01-01

    The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

  18. A cost-benefit analysis of preimplantation genetic diagnosis for carrier couples of cystic fibrosis.

    Science.gov (United States)

    Davis, Lynn B; Champion, Sara J; Fair, Steve O; Baker, Valerie L; Garber, Alan M

    2010-04-01

    To perform a cost-benefit analysis of preimplantation genetic diagnosis (PGD) for carrier couples of cystic fibrosis (CF) compared with the alternative of natural conception (NC) followed by prenatal testing and termination of affected pregnancies. Cost-benefit analysis using a decision analytic model. Outpatient reproductive health practices. A simulated cohort of 1,000 female patients. We calculated the net benefit of giving birth to a child as the present value of lifetime earnings minus lifetime medical costs. Net benefits in dollars. When used for women younger than 35 years of age, the net benefit of PGD over NC was $182,000 ($715,000 vs. $532,000, respectively). For women aged 35-40 years, the net benefit of PGD over NC was $114,000 ($634,000 vs. $520,000, respectively). For women older than 40 years, however, the net benefit of PGD over NC was -$148,000 ($302,000 vs. $450,000, respectively). Preimplantation genetic diagnosis provides net economic benefits when used by carrier couples of CF. Although there is an upper limit of maternal age at which economic benefit can be demonstrated, carrier couples of CF should be offered PGD for prevention of an affected child. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Broken Arm

    Science.gov (United States)

    ... of falling — including football, soccer, gymnastics, skiing and skateboarding — also increases the risk of a broken arm. ... for high-risk activities, such as in-line skating, snowboarding, rugby and football. Don't smoke. Smoking ...

  20. 49 CFR 236.810 - Spectacle, semaphore arm.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Spectacle, semaphore arm. 236.810 Section 236.810 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Spectacle, semaphore arm. That part of a semaphore arm which holds the roundels and to which the blade is...

  1. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2013-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  2. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2012-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  3. Arming shoes of the fifteenth century

    OpenAIRE

    Volken Marquita

    2017-01-01

    Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming sh...

  4. Single-cell-based system to monitor carrier driven cellular auxin homeostasis

    Science.gov (United States)

    2013-01-01

    Background Abundance and distribution of the plant hormone auxin play important roles in plant development. Besides other metabolic processes, various auxin carriers control the cellular level of active auxin and, hence, are major regulators of cellular auxin homeostasis. Despite the developmental importance of auxin transporters, a simple medium-to-high throughput approach to assess carrier activities is still missing. Here we show that carrier driven depletion of cellular auxin correlates with reduced nuclear auxin signaling in tobacco Bright Yellow-2 (BY-2) cell cultures. Results We developed an easy to use transient single-cell-based system to detect carrier activity. We use the relative changes in signaling output of the auxin responsive promoter element DR5 to indirectly visualize auxin carrier activity. The feasibility of the transient approach was demonstrated by pharmacological and genetic interference with auxin signaling and transport. As a proof of concept, we provide visual evidence that the prominent auxin transport proteins PIN-FORMED (PIN)2 and PIN5 regulate cellular auxin homeostasis at the plasma membrane and endoplasmic reticulum (ER), respectively. Our data suggest that PIN2 and PIN5 have different sensitivities to the auxin transport inhibitor 1-naphthylphthalamic acid (NPA). Also the putative PIN-LIKES (PILS) auxin carrier activity at the ER is insensitive to NPA in our system, indicating that NPA blocks intercellular, but not intracellular auxin transport. Conclusions This single-cell-based system is a useful tool by which the activity of putative auxin carriers, such as PINs, PILS and WALLS ARE THIN1 (WAT1), can be indirectly visualized in a medium-to-high throughput manner. Moreover, our single cell system might be useful to investigate also other hormonal signaling pathways, such as cytokinin. PMID:23379388

  5. Efficient carrier relaxation and fast carrier recombination of N-polar InGaN/GaN light emitting diodes

    International Nuclear Information System (INIS)

    Feng, Shih-Wei; Liao, Po-Hsun; Leung, Benjamin; Han, Jung; Yang, Fann-Wei; Wang, Hsiang-Chen

    2015-01-01

    Based on quantum efficiency and time-resolved electroluminescence measurements, the effects of carrier localization and quantum-confined Stark effect (QCSE) on carrier transport and recombination dynamics of Ga- and N-polar InGaN/GaN light-emitting diodes (LEDs) are reported. The N-polar LED exhibits shorter ns-scale response, rising, delay, and recombination times than the Ga-polar one does. Stronger carrier localization and the combined effects of suppressed QCSE and electric field and lower potential barrier acting upon the forward bias in an N-polar LED provide the advantages of more efficient carrier relaxation and faster carrier recombination. By optimizing growth conditions to enhance the radiative recombination, the advantages of more efficient carrier relaxation and faster carrier recombination in a competitive performance N-polar LED can be realized for applications of high-speed flash LEDs. The research results provide important information for carrier transport and recombination dynamics of an N-polar InGaN/GaN LED

  6. Efficient carrier relaxation and fast carrier recombination of N-polar InGaN/GaN light emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Shih-Wei, E-mail: swfeng@nuk.edu.tw; Liao, Po-Hsun [Department of Applied Physics, National University of Kaohsiung, No. 700, Kaohsiung University Rd., Nan Tzu Dist., 811 Kaohsiung, Taiwan (China); Leung, Benjamin; Han, Jung [Department of Electrical Engineering, Yale University, New Haven, Connecticut 06520 (United States); Yang, Fann-Wei [Department of Electronic Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan (China); Wang, Hsiang-Chen [Graduate Institute of Opto-Mechatronics and Advanced Institute of Manufacturing with High-Tech Innovations (AIM-HI), National Chung Cheng University, Chia-Yi, Taiwan (China)

    2015-07-28

    Based on quantum efficiency and time-resolved electroluminescence measurements, the effects of carrier localization and quantum-confined Stark effect (QCSE) on carrier transport and recombination dynamics of Ga- and N-polar InGaN/GaN light-emitting diodes (LEDs) are reported. The N-polar LED exhibits shorter ns-scale response, rising, delay, and recombination times than the Ga-polar one does. Stronger carrier localization and the combined effects of suppressed QCSE and electric field and lower potential barrier acting upon the forward bias in an N-polar LED provide the advantages of more efficient carrier relaxation and faster carrier recombination. By optimizing growth conditions to enhance the radiative recombination, the advantages of more efficient carrier relaxation and faster carrier recombination in a competitive performance N-polar LED can be realized for applications of high-speed flash LEDs. The research results provide important information for carrier transport and recombination dynamics of an N-polar InGaN/GaN LED.

  7. International security and arms control

    International Nuclear Information System (INIS)

    Ekeus, R.

    2000-01-01

    The end of the cold war also ended the focus on the bilateral approach to arms control and disarmament. Key concepts of security needed to be revisited, along with their implications for the disarmament and arms control agenda. Though there is currently a unipolar global security environment, there remain important tasks on the multilateral arms control agenda. The major task is that of reducing and eliminating weapons of mass destruction, especially nuclear weapons. The author contends that maintaining reliance on the nuclear-weapons option makes little sense in a time when the major Powers are strengthening their partnerships in economics, trade, peacemaking and building. (author)

  8. Ab initio theory of charge-carrier conduction in ultrapure organic crystals

    NARCIS (Netherlands)

    Hannewald, K.; Bobbert, P.A.

    2004-01-01

    We present an ab initio description of charge-carrier mobilities in organic molecular crystals of high purity. Our approach is based on Holstein's original concept of small-polaron bands but generalized with respect to the inclusion of nonlocal electron-phonon coupling. By means of an explicit

  9. Measuring the lateral charge-carrier mobility in metal-insulator-semiconductor capacitors via Kelvin-probe.

    Science.gov (United States)

    Milotti, Valeria; Pietsch, Manuel; Strunk, Karl-Philipp; Melzer, Christian

    2018-01-01

    We report a Kelvin-probe method to investigate the lateral charge-transport properties of semiconductors, most notably the charge-carrier mobility. The method is based on successive charging and discharging of a pre-biased metal-insulator-semiconductor stack by an alternating voltage applied to one edge of a laterally confined semiconductor layer. The charge carriers spreading along the insulator-semiconductor interface are directly measured by a Kelvin-probe, following the time evolution of the surface potential. A model is presented, describing the device response for arbitrary applied biases allowing the extraction of the lateral charge-carrier mobility from experimentally measured surface potentials. The method is tested using the organic semiconductor poly(3-hexylthiophene), and the extracted mobilities are validated through current voltage measurements on respective field-effect transistors. Our widely applicable approach enables robust measurements of the lateral charge-carrier mobility in semiconductors with weak impact from the utilized contact materials.

  10. Measuring the lateral charge-carrier mobility in metal-insulator-semiconductor capacitors via Kelvin-probe

    Science.gov (United States)

    Milotti, Valeria; Pietsch, Manuel; Strunk, Karl-Philipp; Melzer, Christian

    2018-01-01

    We report a Kelvin-probe method to investigate the lateral charge-transport properties of semiconductors, most notably the charge-carrier mobility. The method is based on successive charging and discharging of a pre-biased metal-insulator-semiconductor stack by an alternating voltage applied to one edge of a laterally confined semiconductor layer. The charge carriers spreading along the insulator-semiconductor interface are directly measured by a Kelvin-probe, following the time evolution of the surface potential. A model is presented, describing the device response for arbitrary applied biases allowing the extraction of the lateral charge-carrier mobility from experimentally measured surface potentials. The method is tested using the organic semiconductor poly(3-hexylthiophene), and the extracted mobilities are validated through current voltage measurements on respective field-effect transistors. Our widely applicable approach enables robust measurements of the lateral charge-carrier mobility in semiconductors with weak impact from the utilized contact materials.

  11. Effectiveness of screening hospital admissions to detect asymptomatic carriers of Clostridium difficile: a modeling evaluation.

    Science.gov (United States)

    Lanzas, Cristina; Dubberke, Erik R

    2014-08-01

    Both asymptomatic and symptomatic Clostridium difficile carriers contribute to new colonizations and infections within a hospital, but current control strategies focus only on preventing transmission from symptomatic carriers. Our objective was to evaluate the potential effectiveness of methods targeting asymptomatic carriers to control C. difficile colonization and infection (CDI) rates in a hospital ward: screening patients at admission to detect asymptomatic C. difficile carriers and placing positive patients into contact precautions. We developed an agent-based transmission model for C. difficile that incorporates screening and contact precautions for asymptomatic carriers in a hospital ward. We simulated scenarios that vary according to screening test characteristics, colonization prevalence, and type of strain present at admission. In our baseline scenario, on average, 42% of CDI cases were community-onset cases. Within the hospital-onset (HO) cases, approximately half were patients admitted as asymptomatic carriers who became symptomatic in the ward. On average, testing for asymptomatic carriers reduced the number of new colonizations and HO-CDI cases by 40%-50% and 10%-25%, respectively, compared with the baseline scenario. Test sensitivity, turnaround time, colonization prevalence at admission, and strain type had significant effects on testing efficacy. Testing for asymptomatic carriers at admission may reduce both the number of new colonizations and HO-CDI cases. Additional reductions could be achieved by preventing disease in patients who are admitted as asymptomatic carriers and developed CDI during the hospital stay.

  12. Preventing Interstate Armed Conflict : whose responsibility?

    OpenAIRE

    Otunba, Ganiyu

    2010-01-01

    This is a study of interstate armed conflict prevention. The concept of conflict, armed conflict and conflict prevention is defined and explained in order to be able to investigate if there is any single institution saddled with the responsibility of preventing interstate armed conflict and also to verify if adequate efforts are been put in this area which is of importance to mankind. The relationship between conflict prevention, conflict management and conflict resolution is also discussed s...

  13. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  14. Strategic arms limitation

    Science.gov (United States)

    Allen Greb, G.; Johnson, Gerald W.

    1983-10-01

    Following World War II, American scientists and politicians proposed in the Baruch plan a radical solution to the problem of nuclear weapons: to eliminate them forever under the auspices of an international nuclear development authority. The Soviets, who as yet did not possess the bomb, rejected this plan. Another approach suggested by Secretary of War Henry Stimson to negotiate directly with the Soviet Union was not accepted by the American leadership. These initial arms limitation failures both reflected and exacerbated the hostile political relationship of the superpowers in the 1950s and 1960s. Since 1969, the more modest focus of the Soviet-American arms control process has been on limiting the numbers and sizes of both defensive and offensive strategic systems. The format for this effort has been the Strategic Arms Limitatins Talks (Salt) and more recently the Strategic Arms Reduction Talks (START). Both sides came to these negotiations convinced that nuclear arsenals had grown so large that some for of mutual restraint was needed. Although the SALT/START process has been slow and ponderous, it has produced several concrete the agreements and collateral benefits. The 1972 ABM Treaty restricts the deployment of ballistic missile defense systems, the 1972 Interim Agreement places a quantitative freeze on each side's land based and sea based strategic launchers, and the as yet unratified 1979 SALT II Treaty sets numerical limits on all offensive strategic systems and sublimits on MIRVed systems. Collateral benefits include improved verification procedures, working definitions and counting rules, and permanent bureaucratic apparatus which enhance stability and increase the chances for achieving additional agreements.

  15. Carrier dynamics and surface vibration-assisted Auger recombination in porous silicon

    Science.gov (United States)

    Zakar, Ammar; Wu, Rihan; Chekulaev, Dimitri; Zerova, Vera; He, Wei; Canham, Leigh; Kaplan, Andrey

    2018-04-01

    Excitation and recombination dynamics of the photoexcited charge carriers in porous silicon membranes were studied using a femtosecond pump-probe technique. Near-infrared pulses (800 nm, 60 fs) were used for the pump while, for the probe, we employed different wavelengths in the range between 3.4 and 5 μ m covering the medium wavelength infrared range. The data acquired in these experiments consist of simultaneous measurements of the transmittance and reflectance as a function of the delay time between the pump and probe for different pump fluences and probe wavelengths. To evaluate the results, we developed an optical model based on the two-dimensional Maxwell-Garnett formula, incorporating the free-carrier Drude contribution and nonuniformity of the excitation by the Wentzel-Kramers-Brillouin model. This model allowed the retrieval of information about the carrier density as a function of the pump fluence, time, and wavelength. The carrier density data were analyzed to reveal that the recombination dynamics is governed by Shockley-Read-Hall and Auger processes, whereas the diffusion has an insignificant contribution. We show that, in porous silicon samples, the Auger recombination process is greatly enhanced at the wavelength corresponding to the infrared-active vibrational modes of the molecular impurities on the surface of the pores. This observation of surface-vibration-assisted Auger recombination is not only for porous silicon in particular, but for low-dimension and bulk semiconductors in general. We estimate the time constants of Shockley-Read-Hall and Auger processes, and demonstrate their wavelength dependence for the excited carrier density in the range of 1018-10191 /cm3 . We demonstrate that both processes are enhanced by up to three orders of magnitude with respect to the bulk counterpart. In addition, we provide a plethora of the physical parameters evaluated from the experimental data, such as the dielectric function and its dependence on the

  16. Nanostructured Lipid Carriers (NLC) as Vehicles for Topical Administration of Sesamol: In Vitro Percutaneous Absorption Study and Evaluation of Antioxidant Activity.

    Science.gov (United States)

    Puglia, Carmelo; Lauro, Maria Rosaria; Offerta, Alessia; Crascì, Lucia; Micicchè, Lucia; Panico, Anna Maria; Bonina, Francesco; Puglisi, Giovanni

    2017-03-01

    Sesamol is a natural phenolic compound extracted from Sesamum indicum seed oil. Sesamol is endowed with several beneficial effects, but its use as a topical agent is strongly compromised by unfavorable chemical-physical properties. Therefore, to improve its characteristics, the aim of the present work was the formulation of nanostructured lipid carriers as drug delivery systems for topical administration of sesamol.Two different nanostructured lipid carrier systems have been produced based on the same solid lipid (Compritol® 888 ATO) but in a mixture with two different kinds of oil phase such as Miglyol® 812 (nanostructured lipid carrier-M) and sesame oil (nanostructured lipid carrier-PLUS). Morphology and dimensional distribution of nanostructured lipid carriers have been characterized by differential scanning calorimetry and photon correlation spectroscopy, respectively. The release pattern of sesamol from nanostructured lipid carriers was evaluated in vitro determining drug percutaneous absorption through excised human skin. Furthermore, an oxygen radical absorbance capacity assay was used to determine their antioxidant activity.From the results obtained, the method used to formulate nanostructured lipid carriers led to a homogeneous dispersion of particles in a nanometric range. Sesamol has been encapsulated efficiently in both nanostructured lipid carriers, with higher encapsulation efficiency values (> 90 %) when sesame oil was used as the oil phase (nanostructured lipid carrier-PLUS). In vitro evidences show that nanostructured lipid carrier dispersions were able to control the rate of sesamol diffusion through the skin, with respect to the reference formulations.Furthermore, the oxygen radical absorbance capacity assay pointed out an interesting and prolonged antioxidant activity of sesamol, especially when vehiculated by nanostructured lipid carrier-PLUS. Georg Thieme Verlag KG Stuttgart · New York.

  17. Variation in mutation spectrum partly explains regional differences in the breast cancer risk of female BRCA mutation carriers in the Netherlands.

    Science.gov (United States)

    Vos, Janet R; Teixeira, Natalia; van der Kolk, Dorina M; Mourits, Marian J E; Rookus, Matti A; van Leeuwen, Flora E; Collée, Margriet; van Asperen, Christi J; Mensenkamp, Arjen R; Ausems, Margreet G E M; van Os, Theo A M; Meijers-Heijboer, Hanne E J; Gómez-Garcia, Encarna B; Vasen, Hans F; Brohet, Richard M; van der Hout, Annemarie H; Jansen, Liesbeth; Oosterwijk, Jan C; de Bock, Geertruida H

    2014-11-01

    We aimed to quantify previously observed relatively high cancer risks in BRCA2 mutation carriers (BRCA2 carriers) older than 60 in the Northern Netherlands, and to analyze whether these could be explained by mutation spectrum or population background risk. This consecutive cohort study included all known pathogenic BRCA1/2 carriers in the Northern Netherlands (N = 1,050). Carrier and general reference populations were: BRCA1/2 carriers in the rest of the Netherlands (N = 2,013) and the general population in both regions. Regional differences were assessed with HRs and ORs. HRs were adjusted for birth year and mutation spectrum. All BRCA1 carriers and BRCA2 carriers younger than 60 had a significantly lower breast cancer risk in the Northern Netherlands; HRs were 0.66 and 0.64, respectively. Above age 60, the breast cancer risk in BRCA2 carriers in the Northern Netherlands was higher than in the rest of the Netherlands [HR, 3.99; 95% confidence interval (CI), 1.11-14.35]. Adjustment for mutational spectrum changed the HRs for BRCA1, BRCA2 <60, and BRCA2 ≥60 years by -3%, +32%, and +11% to 0.75, 0.50, and 2.61, respectively. There was no difference in background breast cancer incidence between the two regions (OR, 1.03; 95% CI, 0.97-1.09). Differences in mutation spectrum only partly explain the regional differences in breast cancer risk in BRCA2 carriers, and for an even smaller part in BRCA1 carriers. The increased risk in BRCA2 carriers older than 60 may warrant extension of intensive breast screening beyond age 60. ©2014 American Association for Cancer Research.

  18. Amphiphilic star block copolymers as gene carrier Part I: Synthesis via ATRP using calix[4]resorcinarene-based initiators and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Anna; Xue, Yan; Wei, Dafu [Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237 (China); Guan, Yong, E-mail: yguan@ecust.edu.cn [Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237 (China); Xiao, Huining [Department of Chemical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada E3B 5A3 (Canada)

    2013-01-01

    In this work, a cationic star polymer [poly(2-dimethylamino)ethyl methacrylate (PDMAEMA)] was prepared via atom transfer radical polymerization (ATRP), using brominated calix[4]resorcinarene as an initiator. Hydrophobic moieties, methyl methacrylate (MMA) and butyl acrylate (BA), were further incorporated via 'one-pot' method. Well-defined eight-armed star block copolymers bearing hydrophilic blocks inside and hydrophobic blocks outside were synthesized. The molecular weight, particle size, electrophoretic mobility and apparent charge density were determined by gel permeation chromatography (GPC), dynamic light scattering (DLS), phase analysis light scattering (PALS) and colloidal titration, respectively. The zeta potentials and apparent charge densities of the products exhibited the characteristics of polyelectrolyte. The incorporation of hydrophobic moieties generated electrostatic screening effect. The as-synthesized amphiphilic star copolymer is promising as a thermo-sensitive gene carrier for gene therapy. Highlights: Black-Right-Pointing-Pointer Amphiphilic cationic star block copolymers with well-controlled structures were prepared via ATRP. Black-Right-Pointing-Pointer The molecular structures and properties of the initiator and copolymers were systematically characterized. Black-Right-Pointing-Pointer The products exhibited the positive charged character, and hydrophobic moieties generated electrostatic screening effect.

  19. Planet-driven Spiral Arms in Protoplanetary Disks. II. Implications

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    We examine whether various characteristics of planet-driven spiral arms can be used to constrain the masses of unseen planets and their positions within their disks. By carrying out two-dimensional hydrodynamic simulations varying planet mass and disk gas temperature, we find that a larger number of spiral arms form with a smaller planet mass and a lower disk temperature. A planet excites two or more spiral arms interior to its orbit for a range of disk temperatures characterized by the disk aspect ratio 0.04≤slant {(h/r)}p≤slant 0.15, whereas exterior to a planet’s orbit multiple spiral arms can form only in cold disks with {(h/r)}p≲ 0.06. Constraining the planet mass with the pitch angle of spiral arms requires accurate disk temperature measurements that might be challenging even with ALMA. However, the property that the pitch angle of planet-driven spiral arms decreases away from the planet can be a powerful diagnostic to determine whether the planet is located interior or exterior to the observed spirals. The arm-to-arm separations increase as a function of planet mass, consistent with previous studies; however, the exact slope depends on disk temperature as well as the radial location where the arm-to-arm separations are measured. We apply these diagnostics to the spiral arms seen in MWC 758 and Elias 2–27. As shown in Bae et al., planet-driven spiral arms can create concentric rings and gaps, which can produce a more dominant observable signature than spiral arms under certain circumstances. We discuss the observability of planet-driven spiral arms versus rings and gaps.

  20. Altered erythropoiesis and iron metabolism in carriers of thalassemia

    Science.gov (United States)

    Guimarães, Jacqueline S.; Cominal, Juçara G.; Silva-Pinto, Ana Cristina; Olbina, Gordana; Ginzburg, Yelena Z.; Nandi, Vijay; Westerman, Mark; Rivella, Stefano; de Souza, Ana Maria

    2014-01-01

    The thalassemia syndromes (α- and β-thalassemia) are the most common and frequent disorders associated with ineffective erythropoiesis. Imbalance of α- or β-globin chain production results in impaired red blood cell synthesis, anemia and more erythroid progenitors in the blood stream. While patients affected by these disorders show definitive altered parameters related to erythropoiesis, the relationship between the degree of anemia, altered erythropoiesis and dysfunctional iron metabolism have not been investigated in both α-thalassemia carriers (ATC) and β-thalassemia carriers (BTC). Here we demonstrate that ATC have a significantly reduced hepcidin and increased soluble transferrin receptor levels but relatively normal hematological findings. In contrast, BTC have several hematological parameters significantly different from controls, including increased soluble transferrin receptor and erythropoietin levels. These changings in both groups suggest an altered balance between erythropoiesis and iron metabolism. The index sTfR/log ferrin and (hepcidin/ferritin)/sTfR are respectively increased and reduced relative to controls, proportional to the severity of each thalassemia group. In conclusion, we showed in this study, for the first time in the literature, that thalassemia carriers have altered iron metabolism and erythropoiesis. PMID:25307880

  1. Overview of levies on energy carriers in Europe

    International Nuclear Information System (INIS)

    Iten, R.; Gehrig, S.; Koenig, Ch.

    2000-01-01

    This short report for the Swiss Federal Office of Energy (SFOE) examines the situation with respect to levies and steering taxes on various forms of energy in European countries. Comparisons are made with the situation in Switzerland regarding energy prices for various consumer groups, taxation of energy carriers and exceptions for energy-intensive industries. Details are given on prices of energy and the levies imposed, in particular with respect to carbon taxes. Data are given for 11 European countries and detailed information on regulations concerning exceptions is presented for selected countries. Finally, fuel price differences between neighbouring countries are examined and the role of 'motor-fuel-tourism' is discussed

  2. New Design Concept for an Excavator Arms by Using Composite Material

    Science.gov (United States)

    Solazzi, L.; Assi, A.; Ceresoli, F.

    2018-06-01

    The purpose of the present paper is to lightweight design an excavator arms, by using a different materials and in particular composite material. Specifically, the research is based on the study of a commercial excavator, by determining its geometry and analyzing the load conditions to which it is exposed. These are determined in relation to either the load diagram of the machine or the possible utilities of the excavator, such as the rotation of the machine. The materials used and implemented in the different analytical and numerical elaborations are classic construction steel S 355 (UNI EN 10025-3), high-resistance steel S 890 (UNI EN 10025-6), aluminum Al 6063 T6 (UNI EN 573-3) and the composite material made by carbon fiber and epoxy resin. The adopted constraints for the design of new arms with different materials, non-conventional for these applications, are numerous. The new solutions must present a safety factor either with respect to the yield tensile strength or to the critical load of buckling greater than or equal to the one determined for the excavator in its original geometrical conformation. Another criterion, which has heavily conditioned the geometry of the arms, was given by the fact that the developed solutions must present a very similar value of the maximum displacement in the different load conditions analyzed. A new geometry for arms made by composite material was developed. It was an elliptical conic section, instead of the classic rectangular section, in order to use the filament winding technological process. As for the adoption of the composite material, we focused on the study and the design of this material as long as the interaction with the extremities (made of aluminum) which are interfaced either with the link between the arms or with the elements of the hydraulic plant which serves for the arms movement. From the results developed, it emerges that the solution developed by adopting composite materials is the one that permits the

  3. Impact of carriers in oral absorption

    DEFF Research Database (Denmark)

    Gram, Luise Kvisgaard; Rist, Gerda Marie; Lennernäs, Hans

    2009-01-01

    Carriers may mediate the permeation across enterocytes for drug substances being organic anions. Carrier mediated permeation for the organic anions estrone-3-sulfate (ES) and glipizide across Caco-2 cells were investigated kinetically, and interactions on involved carriers evaluated. Initial...

  4. Controlled synthesis of multi-arm star polyether-polycarbonate polyols based on propylene oxide and CO2.

    Science.gov (United States)

    Hilf, Jeannette; Schulze, Patricia; Seiwert, Jan; Frey, Holger

    2014-01-01

    Multi-arm star copolymers based on a hyperbranched poly(propylene oxide) polyether-polyol (hbPPO) as a core and poly(propylene carbonate) (PPC) arms are synthesized in two steps from propylene oxide (PO), a small amount of glycidol and CO2 . The PPC arms are prepared via carbon dioxide (CO2 )/PO copolymerization, using hbPPO as a multifunctional macroinitiator and the (R,R)-(salcy)CoOBzF5 catalyst. Star copolymers with 14 and 28 PPC arms, respectively, and controlled molecular weights in the range of 2700-8800 g mol(-1) are prepared (Mw /Mn = 1.23-1.61). Thermal analysis reveals lowered glass transition temperatures in the range of -8 to 10 °C for the PPC star polymers compared with linear PPC, which is due to the influence of the flexible polyether core. Successful conversion of the terminal hydroxyl groups with phenylisocyanate demonstrates the potential of the polycarbonate polyols for polyurethane synthesis. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Peptide nucleic acid (PNA) cell penetrating peptide (CPP) conjugates as carriers for cellular delivery of antisense oligomers

    DEFF Research Database (Denmark)

    Shiraishi, Takehiko; Nielsen, Peter E

    2012-01-01

    We have explored the merits of a novel delivery strategy for the antisense oligomers based on cell penetrating peptide (CPP) conjugated to a carrier PNA with sequence complementary to part of the antisense oligomer. The effect of these carrier CPP-PNAs was evaluated by using antisense PNA targeting......-PNA (cPNA1(7)-(D-Arg)8) and hexamer carrier decanoyl-CPP-PNA (Deca-cPNA1(6)-(D-Arg)8), respectively, without showing significant additional cellular toxicity. Most interestingly, the activity reached the same level obtained by enhancement with endosomolytic chloroquine (CQ) treatment, suggesting...... that the carrier might facilitate endosomal escape. Furthermore, 50% downregulation of luciferase expression at 60 nM siRNA was obtained using this carrier CPP-PNA delivery strategy (with CQ co-treatment) for a single stranded antisense RNA targeting normal luciferase mRNA. These results indicated that CPP...

  6. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  7. Carrier-added and no-carrier-added syntheses of [18F]spiroperidol and [18F]haloperidol

    International Nuclear Information System (INIS)

    Kilbourn, M.R.; Welch, M.J.; Dence, C.S.; Tewson, T.J.; Saji, H.; Maeda, M.

    1984-01-01

    Syntheses of [ 18 F]haloperidol and [ 18 F]spiroperidol in both no-carrier-added and carrier-added forms have been accomplished. The no-carrier-added [ 18 F]butyrophenone neuroleptics were prepared in low ( 18 F-neuroleptics were prepared in better (5-17%) yields by 18 F-for- 19 F nucleophilic aromatic substitution. The preparation of all synthetic precursors, and procedures for radiolabeling are fully described. (author)

  8. Carrier effect on separation efficiency of the column in reversed-phase partition chromatography

    International Nuclear Information System (INIS)

    Pszonicka, M.; Siekierski, S.

    1972-01-01

    Chromatographic columns were filled with carriers of diatomaceous earth type (Hyflo Super Cell, and Celite 545) of large pores, and two microporous silica gels respectively. These columns were used for the separation of europium and gadolinium by reversed-phase partition chromatography in the system: stationary phase-diethylhexylphosphoric acid (HDEHP) mobile phase-0.4 N nitric acid. In each case the separation of the above mentioned elements was achieved. The plate height that characterizes separation efficiency of the column, decreases with the decrease of particle diameter of the carrier. Best columns were obtained from carriers of large pores (Hyflo Super Cell and Celite 545) for which plate hights below 0.1 mm could be achieved. Columns filled with microporous silica gels showed plate heights of 0.2-0.3 mm. (author)

  9. Compact Dual-Band Dipole Antenna with Asymmetric Arms for WLAN Applications

    Directory of Open Access Journals (Sweden)

    Chung-Hsiu Chiu

    2014-01-01

    Full Text Available A dual-band dipole antenna that consists of a horn- and a C-shaped metallic arm is presented. Depending on the asymmetric arms, the antenna provides two −10 dB impedance bandwidths of 225 MHz (about 9.2% at 2.45 GHz and 1190 MHz (about 21.6% at 5.5 GHz, respectively. This feature enables it to cover the required bandwidths for wireless local area network (WLAN operation at the 2.4 GHz band and 5.2/5.8 GHz bands for IEEE 802.11 a/b/g standards. More importantly, the compact size (7 mm × 24 mm and good radiating performance of the antenna are profitable to be integrated with wireless communication devices on restricted RF-elements spaces.

  10. Limited consensus around ARM information protection practices ...

    African Journals Online (AJOL)

    An existing enterprise IP SoP was adapted to ARM through literature analysis and produced a draft ARM SoP. The draft ARM SoP was applied in a rote fashion to a small sample of government-operated archives to identify likely areas of consensus and lack of consensus surrounding the various elements of the SoP.

  11. 14 CFR 271.4 - Carrier costs.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS GUIDELINES FOR SUBSIDIZING AIR CARRIERS PROVIDING ESSENTIAL AIR TRANSPORTATION § 271.4 Carrier costs. (a) The reasonable costs projected for a carrier providing essential air service at an eligible...

  12. 14 CFR 271.5 - Carrier revenues.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS GUIDELINES FOR SUBSIDIZING AIR CARRIERS PROVIDING ESSENTIAL AIR TRANSPORTATION § 271.5 Carrier revenues. (a) The projected passenger revenue for a carrier providing essential air service at an eligible...

  13. Facilitated transport of hydrophilic salts by mixtures of anion and cation carriers and by ditopic carriers

    NARCIS (Netherlands)

    Chrisstoffels, L.A.J.; de Jong, Feike; Reinhoudt, David; Sivelli, Stefano; Gazzola, Licia; Casnati, Alessandro; Ungaro, Rocco

    1999-01-01

    Anion transfer to the membrane phase affects the extraction efficiency of salt transport by cation carriers 1 and 3. Addition of anion receptors 5 or 6 to cation carriers 1, 3, or 4 in the membrane phase enhances the transport of salts under conditions in which the cation carriers alone do not

  14. Hand-arm vibration disorder among grass-cutter workers in Malaysia.

    Science.gov (United States)

    Azmir, Nor Azali; Ghazali, Mohd Imran; Yahya, Musli Nizam; Ali, Mohamad Hanafi

    2016-09-01

    Prolonged exposure to hand-transmitted vibration from grass-cutting machines has been associated with increasing occurrences of symptoms and signs of occupational diseases related to hand-arm vibration syndrome (HAVS). A cross-sectional study was carried out using an adopted HAVS questionnaire on hand-arm vibration exposure and symptoms distributed to 168 male workers from the grass and turf maintenance industry who use hand-held grass-cutting machines as part of their work. The prevalence ratio and symptom correlation to HAVS between high and low-moderate exposure risk groups were evaluated. There were positive HAVS symptoms relationships between the low-moderate exposure group and the high exposure group among hand-held grass-cutting workers. The prevalence ratio was considered high because there were indicators that fingers turned white and felt numb, 3.63, 95% CI [1.41, 9.39] and 4.24, 95% CI [2.18, 8.27], respectively. Less than 14.3% of workers stated that they were aware of the occupational hand-arm vibration, and it seemed to be related to the finger blanching and numbness. The results suggest that HAVS is under-diagnosed in Malaysia, especially in the agricultural sectors. More information related to safety and health awareness programmes for HAVS exposure is required among hand-held grass-cutting workers.

  15. Lower Robotic Arm Assembly Having a Plurality of Tendon Driven Digits

    Science.gov (United States)

    Guo, Raymond (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Radford, Nicolaus A. (Inventor)

    2016-01-01

    A lower robotic arm includes a base structure, a plurality of digits, and a plurality of tendons. The digits each include first, second, third, and fourth phalanges. Each digit is operatively attached to the base structure at the respective first phalange. A first joint operatively connects the first and second phalange to define a first axis, a second operatively connects the second and third phalange to define a second axis, and a third joint operatively connects the third and fourth phalange to define a third axis, such that the phalanges are selectively rotatable relative to the adjacent phalange, about the respective axis. The tendons are operatively connected to a respective one of the fourth phalanges. Each tendon selectively applies a first torque to the respective fourth phalange to urge the respective phalanges to rotate in a first direction about the respective axes.

  16. Minority Carrier Lifetime and Photoluminescence Studies of Antimony-Based Superlattices

    Science.gov (United States)

    Hoglund, Linda; Soibel, Alexander; Ting, David Z.; Khoshakhlagh, Arezou; Hill, Cory J.; Gunapala, Sarath D.

    2012-01-01

    In this paper, we have used the OMR technique to study the minority carrier lifetimes in three InAs/GaSb-photoluminescence (PL) structures with different number of periods in the absorber: 300, 400 and 600 periods respectively. The feasibility of using a visible 643 nm laser source with short penetration depth for lifetime measurements was studied by comparing the achieved results to measurements performed on the same samples with a 1550 nm IR laser source, which penetrates much deeper into the sample. Despite the differences in excitation wavelengths and penetration depths, the results from both measurements were very similar. This indicates that the diffusion length is long enough to facilitate a homogeneous distribution of excess carriers in the material.

  17. Synthesis of 'no-carrier-added' sup(11)C-labelled nitrosoureas

    International Nuclear Information System (INIS)

    Diksic, M.; Farrokhzad, S.; Yamamoto, Y.L.; Feindel, W.

    1985-01-01

    Syntheses for sup(11)C-labelled chemotherapeutic drugs CCNU, BFNU and CFNU (analogs of BCNU) as well as an improved synthesis for sup(11)C-BCNU are described. The procedures for the separation of dual isomers in the case of sup(11)C-labelled CCNU and CFNU are discussed. The specific activity of these 'no-carrier-added' radiopharmaceuticals was approximately 10sup(4) lower than expected for a carrier-free product. The syntheses were normally finished 20-25 min after the end of the collection of sup(11)C-COClsub(2). Chemical and radiochemical purity of the final products as determined by HPLC and TLRC, respectively, was at least 98%. The syntheses yielded 10-25 mCi of nitrosourea ready for use in PET studies. (author)

  18. Arms Races and Negotiations

    OpenAIRE

    Sandeep Baliga; Tomas Sjostrom

    2003-01-01

    Two players simultaneously decide whether or not to acquire new weapons in an arms race game. Each player's type determines his propensity to arm. Types are private information, and are independently drawn from a continuous distribution. With probability close to one, the best outcome for each player is for neither to acquire new weapons (although each prefers to acquire new weapons if he thinks the opponent will). There is a small probability that a player is a dominant strategy type who alw...

  19. Rolling motions in an inner spiral arm

    International Nuclear Information System (INIS)

    Strauss, F.M.; Poeppel, W.

    1976-01-01

    Hydrogen line observations made at low galactic latitudes for l=318degree, 326degree, 334degree, and 337degree show the presence of velocity gradients in latitude in the nearest inner spiral arm, similar to those found by other observations in different regions. Maximum velocity change is about 10 km s -1 for l=337degree. By generating synthetic line profiles constructed from a model spiral arm, several possible causes of these ''rolling motions'' were studied, such as a vertical displacement or a tilt of the arm (which failed to account for the observations) and rotation or shearing in the arm. It was futher shown that a typical arm can maintain such a motion (approx. =75 km s -1 kpc -1 ) with its own gravitational potential. The results are used to study the origin and tilt of Gould's Belt

  20. A biologically inspired neural network controller for ballistic arm movements

    Directory of Open Access Journals (Sweden)

    Schmid Maurizio

    2007-09-01

    Full Text Available Abstract Background In humans, the implementation of multijoint tasks of the arm implies a highly complex integration of sensory information, sensorimotor transformations and motor planning. Computational models can be profitably used to better understand the mechanisms sub-serving motor control, thus providing useful perspectives and investigating different control hypotheses. To this purpose, the use of Artificial Neural Networks has been proposed to represent and interpret the movement of upper limb. In this paper, a neural network approach to the modelling of the motor control of a human arm during planar ballistic movements is presented. Methods The developed system is composed of three main computational blocks: 1 a parallel distributed learning scheme that aims at simulating the internal inverse model in the trajectory formation process; 2 a pulse generator, which is responsible for the creation of muscular synergies; and 3 a limb model based on two joints (two degrees of freedom and six muscle-like actuators, that can accommodate for the biomechanical parameters of the arm. The learning paradigm of the neural controller is based on a pure exploration of the working space with no feedback signal. Kinematics provided by the system have been compared with those obtained in literature from experimental data of humans. Results The model reproduces kinematics of arm movements, with bell-shaped wrist velocity profiles and approximately straight trajectories, and gives rise to the generation of synergies for the execution of movements. The model allows achieving amplitude and direction errors of respectively 0.52 cm and 0.2 radians. Curvature values are similar to those encountered in experimental measures with humans. The neural controller also manages environmental modifications such as the insertion of different force fields acting on the end-effector. Conclusion The proposed system has been shown to properly simulate the development of

  1. Study on the crystallization of multiarm stars with a poly(ethyleneimine) core and poly(ϵ-caprolactone) arms of different length

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Angélica; Bacaicoa, Anna; Casas, Maria Teresa; Franco, Lourdes [Departament d’Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain); Serra, Angels [Departament de Química Analítica i Química Orgànica, Universitat Rovira i Virgili. C. Marcel.lí Domingo, s/n. Campus Sescelades, Tarragona 43007 (Spain); Puiggalí, Jordi, E-mail: Jordi.Puiggali@upc.edu [Departament d’Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain)

    2015-05-10

    Highlights: • Isothermal crystallization kinetics of multiarm stars. • Influence of the length of poly(ϵ-caprolactone) arms on crystallization kinetics. • Influence of the length of poly(ϵ-caprolactone) arms on secondary nucleation constant. • Crystallization of mixtures of stars having different arm lengths. - Abstract: Crystallization of multiarm star systems constituted by a core of poly(ethyleneimine) (PEI) and arms of poly(ϵ-caprolactone) (PCL) was studied by transmission electron microscopy, calorimetry and optical microscopy techniques. Three systems differing on the degree of polymerization of PCL were studied as well as binary mixtures constituted by systems differing on the length of PCL arms. Samples were able to crystallize from both diluted solutions and the melt state giving rise to well-formed lamellae and spherulites, respectively. Lamellae of samples with large PCL arms were highly regular and corresponded to elongated hexagonal crystals with an aspect ratio that decreased with the length of PCL arms. A significant decrease on equilibrium melting temperatures, degree of crystallinity and glass transition temperature was detected for samples having short PCL arms. Crystallization kinetics were also highly influenced by the length of PCL arms, being both nucleation density and secondary nucleation constant increased as the length of PCL arms decreased. Crystallization of star mixtures having different PCL lengths was determined by the larger arms since they initiated the process and subsequently shorter arms were progressively incorporated. A thermal nucleation was characteristic of multiarm star mixtures due to the different crystallization temperature ranges of samples with large and short PCL arms, whereas samples with a homogeneous arm length rendered an athermal nucleation.

  2. Calcium sensors of ciliary outer arm dynein: functions and phylogenetic considerations for eukaryotic evolution.

    Science.gov (United States)

    Inaba, Kazuo

    2015-01-01

    The motility of eukaryotic cilia and flagella is modulated in response to several extracellular stimuli. Ca(2+) is the most critical intracellular factor for these changes in motility, directly acting on the axonemes and altering flagellar asymmetry. Calaxin is an opisthokont-specific neuronal calcium sensor protein first described in the sperm of the ascidian Ciona intestinalis. It binds to a heavy chain of two-headed outer arm dynein in a Ca(2+)-dependent manner and regulates 'asymmetric' wave propagation at high concentrations of Ca(2+). A Ca(2+)-binding subunit of outer arm dynein in Chlamydomonas reinhardtii, the light chain 4 (LC4), which is a Ca(2+)-sensor phylogenetically different from calaxin, shows Ca(2+)-dependent binding to a heavy chain of three-headed outer arm dynein. However, LC4 appears to participate in 'symmetric' wave propagation at high concentrations of Ca(2+). LC4-type dynein light chain is present in bikonts, except for some subclasses of the Excavata. Thus, flagellar asymmetry-symmetry conversion in response to Ca(2+) concentration represents a 'mirror image' relationship between Ciona and Chlamydomonas. Phylogenetic analyses indicate the duplication, divergence, and loss of heavy chain and Ca(2+)-sensors of outer arm dynein among excavate species. These features imply a divergence point with respect to Ca(2+)-dependent regulation of outer arm dynein in cilia and flagella during the evolution of eukaryotic supergroups.

  3. Carrier-added and no-carrier-added syntheses of (/sup 18/F)spiroperidol and (/sub 18/F)haloperidol

    Energy Technology Data Exchange (ETDEWEB)

    Kilbourn, M R; Welch, M J; Dence, C S; Tewson, T J; Saji, H; Maeda, M

    1984-07-01

    Syntheses of (18F)haloperidol and (18F)spiroperidol in both no-carrier-added and carrier-added forms have been accomplished. The no-carrier-added (18F)butyrophenone neuroleptics were prepared in low (less than 2%) yield by acid decomposition of aryl piperidine triazenes. Carrier-added 18F-neuroleptics were prepared in better (5-17%) yields by 18F-for-19F nucleophilic aromatic substitution. The preparation of all synthetic precursors, and procedures for radiolabeling are fully described.

  4. Surface/Interface Carrier-Transport Modulation for Constructing Photon-Alternative Ultraviolet Detectors Based on Self-Bending-Assembled ZnO Nanowires.

    Science.gov (United States)

    Guo, Zhen; Zhou, Lianqun; Tang, Yuguo; Li, Lin; Zhang, Zhiqi; Yang, Hongbo; Ma, Hanbin; Nathan, Arokia; Zhao, Dongxu

    2017-09-13

    Surface/interface charge-carrier generation, diffusion, and recombination/transport modulation are especially important in the construction of photodetectors with high efficiency in the field of nanoscience. In the paper, a kind of ultraviolet (UV) detector is designed based on ZnO nanostructures considering photon-trapping, surface plasmonic resonance (SPR), piezophototronic effects, interface carrier-trapping/transport control, and collection. Through carefully optimized surface/interface carrier-transport modulation, a designed device with detectivity as high as 1.69 × 10 16 /1.71 × 10 16 cm·Hz 1/2 /W irradiating with 380 nm photons under ultralow bias of 0.2 V is realized by alternating nanoparticle/nanowire active layers, respectively, and the designed UV photodetectors show fast and slow recovery processes of 0.27 and 4.52 ms, respectively, which well-satisfy practical needs. Further, it is observed that UV photodetection could be performed within an alternative response by varying correlated key parameters, through efficient surface/interface carrier-transport modulation, spectrally resolved photoresponse of the detector revealing controlled detection in the UV region based on the ZnO nanomaterial, photodetection allowed or limited by varying the active layers, irradiation distance from one of the electrodes, standing states, or electric field. The detailed carrier generation, diffusion, and recombination/transport processes are well illustrated to explain charge-carrier dynamics contributing to the photoresponse behavior.

  5. Arming shoes of the fifteenth century

    Directory of Open Access Journals (Sweden)

    Volken Marquita

    2017-12-01

    Full Text Available Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming shoes. The question of why medieval military footwear shows no purposed development is addressed.

  6. Facilitated transport near the carrier saturation limit

    Directory of Open Access Journals (Sweden)

    Anawat Sungpet

    2002-11-01

    Full Text Available Permeation of ethylbenzene, styrene and 1-hexene through perfluorosulfonate ionomer membranes was carried out with the feed concentrations ranging from 1 M to pure. On comparison, fluxes of ethylbenzene through the Ag+-form membrane were the lowest. Only a small increase in ethylbenzene flux was observed after the feed concentration exceeded 3 M, indicating the existence of carrier saturation. The increase in styrene flux was suppressed to some degree at high concentration driving forces. In contrast, 1-hexene flux was the highest and continued to increase even at very high feed concentrations. After the experiments with pure feeds, extraction of the solutes from the membranes revealed that 62.5% of Ag+ ions reacted with 1-hexene as against 40.6% for styrene and 28.9% for ethylbenzene. Equilibrium constants, determined by distribution method, of 1-hexene, styrene and ethylbenzene were 129, 2.2 and 0.7 M-1 respectively, which suggested that stability of the complex was a key factor in the carrier saturation phenomenon.

  7. Carrier-added and no-carrier-added syntheses of (/sup 18/F)spiroperidol and (/sup 18/F)haloperidol

    Energy Technology Data Exchange (ETDEWEB)

    Kilbourn, M R; Welch, M J; Dence, C S; Tewson, T J; Saji, H; Maeda, M [Washington Univ., St. Louis, MO (USA). Edward Mallinckrodt Inst. of Radiology

    1984-07-01

    Syntheses of (/sup 18/F)haloperidol and (/sup 18/F)spiroperidol in both no-carrier-added and carrier-added forms have been accomplished. The no-carrier-added (/sup 18/F)butyrophenone neuroleptics were prepared in low (<2%) yield by acid decomposition of aryl piperidine triazenes. Carrier-added /sup 18/F-neuroleptics were prepared in better (5-17%) yields by /sup 18/F-for-/sup 19/F nucleophilic aromatic substitution. The preparation of all synthetic precursors, and procedures for radiolabeling are fully described.

  8. Terror, Failure, Resistance. Conflicting Memory of Armed Acts of Anti-Communist Resistance in Czechoslovakia

    Czech Academy of Sciences Publication Activity Database

    Devátá, Markéta

    -, č. 5 (2017), s. 63-100 ISSN 2336-3142 Institutional support: RVO:68378114 Keywords : resistance * Communist regime * armed acts Subject RIV: AB - History OBOR OECD: History (history of science and technology to be 6.3, history of specific sciences to be under the respective headings)

  9. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  10. [Family paracentric inversion of the short arm of chromosome X (Xp21.2p11.23) and connection with autism spectrum disorders].

    Science.gov (United States)

    Milovančević, Milica Pejović; Vešić, Marija; Jelisavčić, Marko; Nikšić, Snežana; Pilić, Gordana Radivojević; Maravić, Vanja Mandić

    2012-01-01

    Autism spectrum disorders (ASDs) are a group of complex pervasive developmental disorders characterized by impairments in communication, social interaction and behavior. In most cases autism is caused by a combination of genetic factors and environmental risk factors. In 10% to 20% of cases it has been shown that the cause of ASD is genetic. We are describing a 2-year-old boy who was referred to genetic counseling because of speech delay and certain autism-like behavior. By cytogenetic analysis the karyotype 46, inv(X),Y was obtained. The boy was a carrier of a paracentric inversion of the short arm of the chromosome X. After cytogenetic analysis of parental blood, it was detected that mother was a carrier of identical aberration, but had no clinical signs. The method of fluorescent in situ hybridization (FISH) yielded the precise breakpoint in the region (p21.2p11.23). Mother and son were carriers of identical X chromosome. Breakpoints are located in the regions that have already been linked to autism, which indicates that the positional effect of the gene could have been a possible cause of the patient's genotype. In addition to positional effects, in order to better understand the etiology of autism other genetic and environmental factors should be always taken into consideration.

  11. 8 CFR 217.6 - Carrier agreements.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Carrier agreements. 217.6 Section 217.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION REGULATIONS VISA WAIVER PROGRAM § 217... may notify a carrier of the existence of a basis for termination of a carrier agreement under this...

  12. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  13. Simulation of Octopus Arm Based on Coupled CPGs

    OpenAIRE

    Juan Tian; Qiang Lu

    2015-01-01

    The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs) are built and a 2-dimens...

  14. Kinematic decomposition and classification of octopus arm movements

    OpenAIRE

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm move...

  15. Determination of carrier diffusion length in GaN

    Science.gov (United States)

    Hafiz, Shopan; Zhang, Fan; Monavarian, Morteza; Avrutin, Vitaliy; Morkoç, Hadis; Özgür, Ümit; Metzner, Sebastian; Bertram, Frank; Christen, Jürgen; Gil, Bernard

    2015-01-01

    Diffusion lengths of photo-excited carriers along the c-direction were determined from photoluminescence (PL) and cross-sectional cathodoluminescence (CL) measurements in p- and n-type GaN epitaxial layers grown on c-plane sapphire by metal-organic chemical vapor deposition. The investigated samples incorporate a 6 nm thick In0.15Ga0.85N active layer capped with either 500 nm p-GaN or 1500 nm n-GaN. The top GaN layers were etched in steps and PL from the InGaN active region and the underlying layers was monitored as a function of the top GaN thickness upon photo-generation near the surface region by above bandgap excitation. Taking into consideration the absorption in the top GaN layer as well as active and underlying layers, the diffusion lengths at 295 K and at 15 K were measured to be 93 ± 7 nm and 70 ± 7 nm for Mg-doped p-type GaN and 432 ± 30 nm and 316 ± 30 nm for unintentionally doped n-type GaN, respectively, at photogenerated carrier densities of 4.2 × 1018 cm-3 using PL spectroscopy. CL measurements of the unintentionally doped n-type GaN layer at much lower carrier densities of 1017 cm-3 revealed a longer diffusion length of 525 ± 11 nm at 6 K.

  16. Measurements of the LHCb software stack on the ARM architecture

    International Nuclear Information System (INIS)

    Kartik, S Vijay; Couturier, Ben; Clemencic, Marco; Neufeld, Niko

    2014-01-01

    The ARM architecture is a power-efficient design that is used in most processors in mobile devices all around the world today since they provide reasonable compute performance per watt. The current LHCb software stack is designed (and thus expected) to build and run on machines with the x86/x86 6 4 architecture. This paper outlines the process of measuring the performance of the LHCb software stack on the ARM architecture – specifically, the ARMv7 architecture on Cortex-A9 processors from NVIDIA and on full-fledged ARM servers with chipsets from Calxeda – and makes comparisons with the performance on x86 6 4 architectures on the Intel Xeon L5520/X5650 and AMD Opteron 6272. The paper emphasises the aspects of performance per core with respect to the power drawn by the compute nodes for the given performance – this ensures a fair real-world comparison with much more 'powerful' Intel/AMD processors. The comparisons of these real workloads in the context of LHCb are also complemented with the standard synthetic benchmarks HEPSPEC and Coremark. The pitfalls and solutions for the non-trivial task of porting the source code to build for the ARMv7 instruction set are presented. The specific changes in the build process needed for ARM-specific portions of the software stack are described, to serve as pointers for further attempts taken up by other groups in this direction. Cases where architecture-specific tweaks at the assembler lever (both in ROOT and the LHCb software stack) were needed for a successful compile are detailed – these cases are good indicators of where/how the software stack as well as the build system can be made more portable and multi-arch friendly. The experience gained from the tasks described in this paper are intended to i) assist in making an informed choice about ARM-based server solutions as a feasible low-power alternative to the current compute nodes, and ii) revisit the software design and build system for portability and

  17. Phase II, two-arm RTOG trial (94-11) of bischloroethyl-nitrosourea plus accelerated hyperfractionated radiotherapy (64.0 or 70.4 Gy) based on tumor volume (> 20 or ≤ 20 cm2, respectively) in the treatment of newly-diagnosed radiosurgery-ineligible glioblastoma multiforme patients

    International Nuclear Information System (INIS)

    Coughlin, C.; Scott, C.; Langer, C.; Coia, L.; Curran, W.; Rubin, P.

    2000-01-01

    Purpose: To compare survivorship, and acute and delayed toxicities following radiation therapy (RT) of radiosurgery-ineligible glioblastoma multiforme (GBM) patients treated with tumor volume-influenced, high-dose accelerated, hyperfractionated RT plus bischloroethyl-nitrosourea (BCNU), using prior RTOG malignant glioblastoma patients as historical controls. Methods and Materials: One hundred four of 108 patients accrued from June 1994 through May 1995 from 26 institutions were analyzable. Patients were histologically confirmed with GBM, and previously untreated. Treatment assignment (52 patients/arm) was based on tumor mass (TM), defined as the product of the maximum diameter and greatest perpendicular dimension of the titanium-gadolinium-enhanced postoperative MRI: Arm A, 64 Gy, TM > 20 cm 2 ; or Arm B, 70.4 Gy, TM ≤ 20 cm 2 . Both Arms A and B received BCNU (80 mg/m 2 , under hyperhydration) days 1-3, 56-58, then 4 cycles, each 8 weeks, for a total of 6 treatment series. Results: During the 24 months immediately post-treatment, the overall median survival was 9.1 months in Arm A (64 Gy) and 11.0 months in Arm B (70.4 Gy). Median survival in recursive partitioning analysis (RPA) Class III/IV was 10.4 months in Arm A and 12.2 months in Arm B, while RPA Class V/VI was 7.6 months in Arm A and 6.1 months in Arm B. There were no grade 4 neurological toxicities in Arm A; 2 grade 4 neurological toxicities were observed in Arm B (1 motor deficit, 1 necrosis at 157 days post-treatment). Conclusion: This strategy of high-dose, accelerated hyperfractionated radiotherapy shortens overall RT treatment times while allowing dose escalation, and it provides the potential for combination with currently available, as well as newer, chemotherapy agents. Survival is comparable with previously published RTOG data, and toxicities are within acceptable limits.

  18. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  19. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  20. Estimating motor carrier management information system crash file underreporting from carrier records : research brief.

    Science.gov (United States)

    2017-08-01

    This study estimated a significant amount of underreporting to the MCMIS crash file by the States, for the carriers who cooperated in the study. For the study carriers, it appears that the MCMIS file contained about 66 percent of their reportable cra...

  1. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  2. Nuclear Arms Race and Environment

    OpenAIRE

    Li, Anpeng

    2012-01-01

    This paper introduces a new factor, environment, into nuclear arms race model. In this model, nuclear weapons produce larger defense power compared with conventional arms, but hurt the environment meanwhile. In the global welfare maximum level, both conventional and nuclear weapons budget are zero. However, the competitive equilibrium may not achieve the optimum. I give the condition to jump out of the prisoner's dilemma.

  3. Deterioration of bioplastic carrier bags in the environment and assessment of a new recycling alternative.

    Science.gov (United States)

    Accinelli, Cesare; Saccà, Maria Ludovica; Mencarelli, Mariangela; Vicari, Alberto

    2012-09-01

    Increasing environmental concerns and the introduction of technologies based on renewable resources have stimulated the replacement of persistent petroleum-derived plastics with biodegradable plastics from biopolymers. As a consequence, a variety of products are currently manufactured from bioplastic, including carrier bags. This series of studies investigated the deterioration of carrier bags made with Mater-Bi (MB), a starch-based bioplastic, in soil, compost and two aquatic ecosystems, a littoral marsh and seawater. Results from the laboratory study indicated that bioplastic carrier bags were rapidly deteriorated in soil and compost. After three months of incubation, weight loss of specimens was of 37% and 43% in soil and compost, respectively. Conversely, little deterioration was observed in specimens buried in soil under field conditions or exposed to water of a littoral marsh and of the Adriatic Sea. These findings were consistent with the greater number of bacteria and especially fungi capable of degrading MB that were recovered from soil and compost with respect to the two aquatic ecosystems. Considering that a variety of microbial isolates are capable of using MB as a source of carbon, a new alternative to recycle these MB-based carrier bags was explored. More specifically, starchy residues from bags were fermented by the fungus Rhizopus oryzae to produce up to 35 mg of lactic acid per g of bag residues. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Planet-driven Spiral Arms in Protoplanetary Disks. I. Formation Mechanism

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    Protoplanetary disk simulations show that a single planet can excite more than one spiral arm, possibly explaining the recent observations of multiple spiral arms in some systems. In this paper, we explain the mechanism by which a planet excites multiple spiral arms in a protoplanetary disk. Contrary to previous speculations, the formation of both primary and additional arms can be understood as a linear process when the planet mass is sufficiently small. A planet resonantly interacts with epicyclic oscillations in the disk, launching spiral wave modes around the Lindblad resonances. When a set of wave modes is in phase, they can constructively interfere with each other and create a spiral arm. More than one spiral arm can form because such constructive interference can occur for different sets of wave modes, with the exact number and launching position of the spiral arms being dependent on the planet mass as well as the disk temperature profile. Nonlinear effects become increasingly important as the planet mass increases, resulting in spiral arms with stronger shocks and thus larger pitch angles. This is found to be common for both primary and additional arms. When a planet has a sufficiently large mass (≳3 thermal masses for (h/r) p = 0.1), only two spiral arms form interior to its orbit. The wave modes that would form a tertiary arm for smaller mass planets merge with the primary arm. Improvements in our understanding of the formation of spiral arms can provide crucial insights into the origin of observed spiral arms in protoplanetary disks.

  5. The Kinetics of Carrier Transport Inhibition

    DEFF Research Database (Denmark)

    Rosenberg, T.; Wilbrandt, Robert Walter

    1962-01-01

    The kinetical treatment of enzymatic carrier transports as given in previous communications has been extended to conditions of inhibition. Various possible types of inhibitors have been considered differing in the site of attack (enzyme or carrier), in the mode of action (competing with the subst......The kinetical treatment of enzymatic carrier transports as given in previous communications has been extended to conditions of inhibition. Various possible types of inhibitors have been considered differing in the site of attack (enzyme or carrier), in the mode of action (competing...... with the substrate for the enzyme or the carrier or for both, competing with the carrier for the enzyme, or non-competitive) and in the ability of penetrating the membrane. Experiments are reported on the inhibition of glucose and fructose transport across the human red cell membrane by phlorizine, phloretine...... and polyphloretinephosphate. The results of the analysis for these inhibitors indicate a substrate competitive mode of action. The effect of reversing the transport direction by interchanging the substrate concentration has been treated for the case of a non-penetrating substrate competitive inhibitor in the external medium...

  6. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  7. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  8. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  9. Charge-carrier mobilities in disordered semiconducting polymers : effects of carrier density and electric field

    NARCIS (Netherlands)

    Meisel, K.D.; Pasveer, W.F.; Cottaar, J.; Tanase, C.; Coehoorn, R.; Bobbert, P.A.; Blom, P.W.M.; Leeuw, D.M. de; Michels, M.A.J.

    2006-01-01

    We model charge transport in disordered semiconducting polymers by hopping of charge carriers on a square lattice of sites with Gaussian on-site energy disorder, using Fermi-Dirac statistics. From numerically exact solutions of the Master equation, we study the dependence of the charge-carrier

  10. LIQUIFIED NATURAL GAS (LNG) CARRIERS

    OpenAIRE

    Daniel Posavec; Katarina Simon; Matija Malnar

    2010-01-01

    Modern liquefied natural gas carriers are double-bottom ships classified according to the type of LNG tank. The tanks are specially designed to store natural gas cooled to -161°C, the boiling point of methane. Since LNG is highly flammable, special care must be taken when designing and operating the ship. The development of LNG carriers has begun in the middle of the twentieth century. LNG carrier storage space has gradually grown to the current maximum of 260000 m3. There are more than 300 L...

  11. Risk factors associated with multidrug-resistant tuberculosis (MDR-TB) in a tertiary armed force referral and teaching hospital, Ethiopia.

    Science.gov (United States)

    Demile, Biresaw; Zenebu, Amare; Shewaye, Haile; Xia, Siqing; Guadie, Awoke

    2018-05-31

    Ethiopia is one of the world health organization defined higher tuberculosis (TB) burden countries where the disease remains a massive public health threat. This study aimed to identify the prevalence and associated factors of multidrug-resistant tuberculosis (MDR-TB) using all armed force and civilian TB attendants in a tertiary level armed force hospital, where data for MDR-TB are previously unpublished. Cross-sectional study was conducted from September 2014 to August 2015 in a tertiary level Armed Force Referral and Teaching Hospital (AFRTH), Ethiopia. Armed force members (n = 251) and civilians (n = 130) which has been undergone TB diagnosis at AFRTH were included. All the specimens collected were subjected to microscopic smear observation, culture growth and drug susceptibility testing. Data were analyzed using statistical package for social sciences following binary logistic regression and Chi-square. P-values < 0.05 were considered statistically significant. Among 381 TB patients, 355 (93.2%) new and 26 (6.8%) retreatment cases were identified. Culture and smear positive TB cases were identified in 297 (77.9%) and 252 (66.1%) patients, respectively. The overall prevalence of MDR-TB in AFRTH was found 1.8% (1.3% for armed force members and 0.5% for civilian patients) all of which were previously TB treated cases. The entire treatment success rates were 92.6% achieved highest in the armed force (active and pension) than the civilian patients. The failure and dead cases were also found 2.5 and 4.6%, respectively. Using bivariate analysis, category of attendants and TB contact history were strong predictors of MDR-TB in armed force and civilian patients. Moreover, human immunodeficiency virus (HIV) infection also identified a significant (OR = 14.6; 95% CI = 2.3-92.1; p = 0.004) predicting factor for MDR-TB in armed force members. However, sex, age and body mass index were not associated factor for MDR-TB. In AFRTH, lower prevalence of

  12. Defining and comparing learning actions in two simulation modalities: students training on a latex arm and each other's arms.

    Science.gov (United States)

    Ravik, Monika; Havnes, Anton; Bjørk, Ida Torunn

    2017-12-01

    To explore, describe and compare learning actions that nursing students used during peripheral vein cannulation training on a latex arm or each other's arms in a clinical skills centre. Simulation-based training is thought to enhance learning and transfer of learning from simulation to the clinical setting and is commonly recommended in nursing education. What students actually are doing during simulation-based training is, however, less explored. The analysis of learning actions used during simulation-based training could contribute to development and improvement of simulation as a learning strategy in nursing education. A qualitative explorative and descriptive research design, involving content analysis of video recordings, was used. Video-supported observation of nine nursing students practicing vein cannulation was conducted in a clinical skills centre in late 2012. The students engaged in various learning actions. Students training on a latex arm used a considerably higher number of learning actions relative to those training on each other's arms. In both groups, students' learning actions consisted mainly of seeking and giving support. The teacher provided students training on each other's arms with detailed feedback regarding insertion of the cannula into the vein, while those training on a latex arm received sparse feedback from the teacher and fellow students. The teacher played an important role in facilitating nursing students' practical skill learning during simulation. The provision of support from both teachers and students should be emphasised to ensure that nursing students' learning needs are met. This study suggest that student nurses may be differently and inadequately prepared in peripheral vein cannulation in two simulation modalities used in the academic setting; training on a latex arm and on each other's arms. © 2017 John Wiley & Sons Ltd.

  13. Passivity-Based Control of Rotational and Translational Timoshenko Arms

    Directory of Open Access Journals (Sweden)

    Minoru Sasaki

    2012-01-01

    Full Text Available It is shown that the alternate passivity-based control schemes can be designed which explicitly exploit the passivity properties of the Timoshenko model. This approach has the advantage over the conventional methods in the respect that it allows one to deal directly with the system's partial differential equations without resorting to approximations. Numerical results for the tracking control of a translational and rotational flexible Timoshenko arm are presented and compared. They verify that the proposed control schemes are effective at controlling flexible dynamical systems.

  14. Clinical, ultrasonographic, and roentgenographic study in 134 asymptomatic gallstone carriers

    International Nuclear Information System (INIS)

    Lirussi, F.; Passera, D.; Iemmolo, R.M.; Nassuato, G.; Okolicsanyi, L.

    1993-01-01

    The authors investigated retrospectively the ultrasonographic and roentgenographic characteristics of the gallstones and the gallbladder in 134 symtom-free carriers and evaluated prospectively the outcome and side effects of 6 to 24 months' ursodeoxycholic acid (UDCA) therapy in 36 individuals with silent stones. Two-thirds of the 134 subjects had multiple stones, and 71 to 75% had stones less than 15 mm in diameter. Gallstone calcification was detected in 13%. A non-functioning gallbladder was observed in 19%, whereas gallbladder contraction was normal in 64 of 76 gallstone carriers. With regard to oral bile acid treatment, complete and partial dissolutions were achieved in 7 and 9 of 33 subjects, respectively (48.5%). Development of a non-functioning gallbladder occurred in 9%, and acquired gallstone calcification was seen in another 15%. It is concluded that: i) the characteristics of the gallstones and the gallbladder are similar to those observed in symptomatic patients, and ii) UDCA therapy may be given in selected symptom-free carriers for no more than 6 to 12 months. Thereafter, it does not appear to be cost-effective. 23 refs., 2 figs., 3 tabs

  15. Bacterial Carriers for Glioblastoma Therapy

    Directory of Open Access Journals (Sweden)

    Nalini Mehta

    2017-03-01

    Full Text Available Treatment of aggressive glioblastoma brain tumors is challenging, largely due to diffusion barriers preventing efficient drug dosing to tumors. To overcome these barriers, bacterial carriers that are actively motile and programmed to migrate and localize to tumor zones were designed. These carriers can induce apoptosis via hypoxia-controlled expression of a tumor suppressor protein p53 and a pro-apoptotic drug, Azurin. In a xenograft model of human glioblastoma in rats, bacterial carrier therapy conferred a significant survival benefit with 19% overall long-term survival of >100 days in treated animals relative to a median survival of 26 days in control untreated animals. Histological and proteomic analyses were performed to elucidate the safety and efficacy of these carriers, showing an absence of systemic toxicity and a restored neural environment in treated responders. In the treated non-responders, proteomic analysis revealed competing mechanisms of pro-apoptotic and drug-resistant activity. This bacterial carrier opens a versatile avenue to overcome diffusion barriers in glioblastoma by virtue of its active motility in extracellular space and can lead to tailored therapies via tumor-specific expression of tumoricidal proteins.

  16. Basic Stand Alone Carrier Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Carrier Line Items Public Use Files (PUF) with information from Medicare Carrier claims. The CMS BSA Carrier Line...

  17. Nasal carriers are more likely to acquire exogenous Staphylococcus aureus strains than non-carriers.

    Science.gov (United States)

    Ghasemzadeh-Moghaddam, H; Neela, V; van Wamel, W; Hamat, R A; Shamsudin, M Nor; Hussin, N Suhaila Che; Aziz, M N; Haspani, M S Mohammad; Johar, A; Thevarajah, S; Vos, M; van Belkum, A

    2015-11-01

    We performed a prospective observational study in a clinical setting to test the hypothesis that prior colonization by a Staphylococcus aureus strain would protect, by colonization interference or other processes, against de novo colonization and, hence, possible endo-infections by newly acquired S. aureus strains. Three hundred and six patients hospitalized for >7 days were enrolled. For every patient, four nasal swabs (days 1, 3, 5, and 7) were taken, and patients were identified as carriers when a positive nasal culture for S. aureus was obtained on day 1 of hospitalization. For all patients who acquired methicillin-resistant S. aureus (MRSA) or methicillin-susceptible S. aureus via colonization and/or infection during hospitalization, strains were collected. We note that our study may suffer from false-negative cultures, local problems with infection control and hospital hygiene, or staphylococcal carriage at alternative anatomical sites. Among all patients, 22% were prior carriers of S. aureus, including 1.9% whom carried MRSA upon admission. The overall nasal staphylococcal carriage rate among dermatology patients was significantly higher than that among neurosurgery patients (n = 25 (55.5%) vs. n = 42 (16.1%), p 0.005). This conclusion held when the carriage definition included individuals who were nasal culture positive on day 1 and day 3 of hospitalization (p 0.0001). All MRSA carriers were dermatology patients. There was significantly less S. aureus acquisition among non-carriers than among carriers during hospitalization (p 0.005). The mean number of days spent in the hospital before experiencing MRSA acquisition in nasal carriers was 5.1, which was significantly lower than the score among non-carriers (22 days, p 0.012). In conclusion, we found that nasal carriage of S. aureus predisposes to rather than protects against staphylococcal acquisition in the nose, thereby refuting our null hypothesis. Copyright © 2015 European Society of Clinical

  18. Enhanced piezoelectric operation of NiO/GaN heterojunction generator by suppressed internal carrier screening

    International Nuclear Information System (INIS)

    Jeong, Dae Kyung; Kang, Jin-Ho; Ryu, Sang-Wan; Ha, Jun-Seok

    2017-01-01

    A NiO/GaN heterojunction piezoelectric generator was fabricated, and the improvement in device performance was analyzed. The electrical properties of NiO were varied by regulating the gas environment during sputtering. An optimized NiO layer was adopted for high piezoelectric voltage generation. Internal carrier screening was revealed to be the dominant mechanism degrading the piezoelectric performance, necessitating the suppression of carrier screening. The highly resistive NiO layer was advantageous in the suppression of carrier transport across the junction that screened the piezoelectric field. The maximum piezoelectric voltage and current density values obtained were 7.55 V and 1.14 µ A cm −2 , respectively. The power obtained was sufficient to operate a light-emitting diode combined with a charging circuit. (paper)

  19. Blood pressure differences between arms and association of dominant hands with blood pressure differences and carotid atherosclerosis.

    Science.gov (United States)

    Maeda, Shinji

    2013-06-01

    Guidelines for the management of hypertension recommend that blood pressure (BP) should be measured twice at every visit; it should be measured in both arms at the first visit, and the right arm BP or higher BP should be recorded. Manufacturers of home BP monitors tend to design the device for measurement of left arm BP. The arm preferred for BP measurement differs according to the methods recommended by the society and according to the home BP monitors. The BP difference (ΔBP) is calculated by subtracting left arm BP from right arm BP. Here, we aim to first investigate which hand will give the most accurate reading by a sphygmomanometer in daily medical practice. Second, we wish to assess the association of the dominant hand with absolute BP difference (|ΔBP|) of at least 10 mmHg and with early atherosclerotic markers in a subanalysis. We found that 6.4% of outpatients were left handed, and the percentage of individuals with systolic |ΔBP| (|ΔSBP|) and diastolic |ΔBP| (|ΔDBP|) of at least 10 mmHg was 14.4 and 7.2%, respectively. The dominant hand was not significantly associated with |ΔBP| of at least 10 mmHg or early atherosclerotic markers. This study suggests that BP measured in one arm is substitutable with that of the other arm because of a lack of association of |ΔBP| with the dominant hand. However, BP of both arms should be actively measured in new outpatients with moderate fever, lifestyle-related diseases, vascular events, age 65 years and above, and smoking history, all of which are factors potentially associated with |ΔBP| of at least 10 mmHg, regardless of the dominant hand.

  20. The analysis of spatial relationship between the rotator cuff and the subacromial space in different arm positions

    International Nuclear Information System (INIS)

    Zou Yuefen; Wang Dehang; Wang Xiaoning; Li Shener

    2003-01-01

    Objective: To explore the distance between the acromion and the humerus head at different arm abduction to observe whether it changes or not, to determine at which position the distance is smallest, and to evaluate the relationship between the subacromial space and the rotator cuff. Methods: Fifteen normal volunteers were examined with MRI in six arm positions, and the coronal thin images were obtained with a spin echo sequence. Using a special positioning device, the arm was placed at 0 degree, 30 degree, 60 degree, 90 degree, 120 degree and 150 degree arm abduction, respectively. Of them, 0 degree-90 degree positions were not rotated, while 120 degree and 150 degree positions were slight internal rotated. The minimal distance of acromion-humerus (A-H) and clavicle-humerus (C-H), and the spatial relationship between the rotator cuff and the subacromial space were measured and observed. Results: The values of A-H and C-H at 60 degree - 150 degree arm abduction were obviously smaller than those at 0 degree-30 degree arm abduction (P 0.05). The rotator cuff (mainly supraspinatus tendon) just went through between the acromion and the humerus at 60 degree - 120 degree arm positions but not at 0 degree, 30 degree and 150 degree arm positions. So at 60 degree - 120 degree arm positions, rotator cuff between the humerus and the acromion was often impinged. Conclusion: The closest contact between the supraspinatus tendon and subacromial space occurs at 60 degree - 120 degree abduction. The findings testify that the patients with impingement syndrome have shoulder pain at 60 degree - 120 degree abduction in clinic from etiology and pathology. In the future, MRI-based analyses should allow investigating the morphological basis of the impingement syndrome, choosing the appropriate therapy, and minimizing failure rates of surgery

  1. Relative Contribution of Arms and Legs in 30 s Fully Tethered Front Crawl Swimming

    Directory of Open Access Journals (Sweden)

    Pedro G. Morouço

    2015-01-01

    Full Text Available The relative contribution of arm stroke and leg kicking to maximal fully tethered front crawl swimming performance remains to be solved. Twenty-three national level young swimmers (12 male and 11 female randomly performed 3 bouts of 30 s fully tethered swimming (using the whole body, only the arm stroke, and only the leg kicking. A load-cell system permitted the continuous measurement of the exerted forces, and swimming velocity was calculated from the time taken to complete a 50 m front crawl swim. As expected, with no restrictions swimmers were able to exert higher forces than that using only their arm stroke or leg kicking. Estimated relative contributions of arm stroke and leg kicking were 70.3% versus 29.7% for males and 66.6% versus 33.4% for females, with 15.6% and 13.1% force deficits, respectively. To obtain higher velocities, male swimmers are highly dependent on the maximum forces they can exert with the arm stroke (r=0.77, P<0.01, whereas female swimmers swimming velocity is more related to whole-body mean forces (r=0.81, P<0.01. The obtained results point that leg kicking plays an important role over short duration high intensity bouts and that the used methodology may be useful to identify strength and/or coordination flaws.

  2. Kinematic decomposition and classification of octopus arm movements.

    Science.gov (United States)

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  3. Star distribution in the Orion spiral arm

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1985-01-01

    The structure of the Orion spiral arm is studied by numerical experiments, assuming that in each direction considered the star distribution along the line of sight is a combination of two Gaussian laws. The corresponding parameters are evaluated for four Milky Way fields; the bimodal laws now fit the observations by the chi 2 criterion. In the Orion arm the line-of-sight star densities follow asymmetric curves, steeper at the outer edge of the arm

  4. Ultrafast carrier dynamics in tetrahedral amorphous carbon: carrier trapping versus electron-hole recombination

    International Nuclear Information System (INIS)

    Carpene, E; Mancini, E; Dallera, C; Schwen, D; Ronning, C; Silvestri, S De

    2007-01-01

    We report the investigation of the ultrafast carrier dynamics in thin tetrahedral amorphous carbon films by means of femtosecond time-resolved reflectivity. We estimated the electron-phonon relaxation time of a few hundred femtoseconds and we observed that under low optical excitation photo-generated carriers decay according to two distinct mechanisms attributed to trapping by defect states and direct electron-hole recombination. With high excitation, when photo-carrier and trap densities are comparable, a unique temporal evolution develops, as the time dependence of the trapping process becomes degenerate with the electron-hole recombination. This experimental evidence highlights the role of defects in the ultrafast electronic dynamics and is not specific to this particular form of carbon, but has general validity for amorphous and disordered semiconductors

  5. No differences in brain microstructure between young KIBRA-C carriers and non-carriers.

    Science.gov (United States)

    Hu, Li; Xu, Qunxing; Li, Jizhen; Wang, Feifei; Xu, Xinghua; Sun, Zhiyuan; Ma, Xiangxing; Liu, Yong; Wang, Qing; Wang, Dawei

    2018-01-02

    KIBRA rs17070145 polymorphism is associated with variations in memory function and the microstructure of related brain areas. Diffusion kurtosis imaging (DKI) as an extension of diffusion tensor imaging that can provide more information about changes in microstructure, based on the idea that water diffusion in biological tissues is heterogeneous due to structural hindrance and restriction. We used DKI to explore the relationship between KIBRA gene polymorphism and brain microstructure in young adults. We recruited 100 healthy young volunteers, including 53 TT carriers and 47 C allele carriers. No differences were detected between the TT homozygotes and C-allele carriers for any diffusion and kurtosis parameter. These results indicate KIBRA rs17070145 polymorphism likely has little or no effect on brain microstructure in young adults.

  6. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  7. Passive detection of nuclear-armed SLCMs

    International Nuclear Information System (INIS)

    Sagdeev, R.Z.; Prilutsky, O.F.; Frolov, V.A.

    1992-01-01

    Effective procedures have been developed, using national technical measures (photoreconnaissance satellites, radiointercept stations, etc.), for verification of reductions in land-based intercontinental ballistic missiles, such as marine-based ballistic missiles, and strategic bombers. However, there is agreement on procedures for verifying limitations of numbers of long-range nuclear-armed cruise missiles. The difficulties in developing such procedures are sometimes regarded (by opponents of nuclear disarmament) as a reason why cruise missiles based on ships and submarines ought not to be limited by future arms-reduction treaties. This paper considers the detectability of nuclear-armed cruise missiles through the penetrating radiation emitted spontaneously from their warheads

  8. Femtosecond pump-probe studies of phonons and carriers in bismuth under high pressure

    International Nuclear Information System (INIS)

    Kasami, M.; Ogino, T.; Mishina, T.; Yamamoto, S.; Nakahara, J.

    2006-01-01

    We investigate the high-pressure phase of Bi under hydrostatic pressure using pump-probe spectroscopy at pressures up to 3.0 GPa, and we observe coherent phonons signal and relaxation signal of photo-excited carriers at Bi(II) and Bi(III) phases. The pressure dependence of the coherent phonons shows that the amplitude of coherent phonons is extremely small and the frequency of coherent phonons changes at high-pressure phases. As results from our experiment, we obtain its frequencies are 2.5 and 2.2 THz at Bi(II) and Bi(III), respectively. Furthermore, photo-excited carrier relaxation indicates drastic changes near 2.5 GPa. Bismuth transforms from semimetal to semiconductor near 2.5 GPa, and band-overlapping between at L-point and at T-point disappears. We consider that the drastic changes of the photo-excited carrier relaxation are strongly correlated with the band-overlapping disappearing

  9. Preparation of microorganism free carrier for biofertilizer product

    International Nuclear Information System (INIS)

    Latiffah Norddin; Maizatul Akmam Mhd Nasir; Phua Choo Kwai Hoe

    2007-01-01

    Biofertilizer has been identified as an alternative or complementary to chemical fertilizer to increase soil fertility and crop production in sustainable farming. Biofertilizers are products containing living cells of different types of known microorganisms that may increase crop productivity through N2 fixation, phosphate solubilization or stimulation of plant growth by synthesising phytohormones. A good biofertilizer product needs a good carrier or substrate. A good carrier is free from microbial contamination and can optimise the growth of the biofertilizer microorganisms. Compost is commonly used as carrier or substrate for biofertilizer microorganisms. In the present study, compost produced by Nuclear Malaysia using the Natural Farming was used as a carrier for the biofertilizer products. Gamma irradiation has been used to produce a ?clean? or sterile carrier. The sterilization effect of the carrier was checked by using serial dilution technique. Carriers that were irradiated at 50 kGy of gamma irradiation were found to be sterile. The shelf life of the sterile carriers was also determined. After six months the compost carriers were still free from microbial contamination. (Author)

  10. Carrier-mediated transport of peptides by the kidney

    International Nuclear Information System (INIS)

    Skopicki, H.A.

    1988-01-01

    Small peptide transport was characterized to determine if: (1) Multiple carriers are present in the luminal membrane of renal proximal tubular cells; (2) Carrier-mediated peptide transport is limited by size; and (3) Gentamicin inhibits carrier-mediated reabsorption of peptides. Uptake of glycyl-[ 3 H]proline (Gly-Pro) into renal brush border membrane vesicles demonstrated a dual affinity carrier system. Whether multiple carriers are present was further investigated by characterizing the uptake of [ 3 H]pyroglutamyl-histidine. To determine if carrier-mediated transport of peptides is limited by size of the molecule, uptake of the hydrolytically resistant tripeptide, [ 3 H]pryroglutamyl-histidyl-tryptophan (pGlu-His-Trp), and tetrapeptide, [ 3 H]pyroglutamyl-histidyl-tryptophyl-serine (pGlu-His-Trp-Ser) were assessed. These data indicate: multiple carriers exist on the luminal membrane of renal proximal tubular cells for the transport of dipeptides, and tripeptide pGlu-His-Trp and the tetrapeptide pGlu-His-Trp-Ser are not taken up by a carrier-mediated mechanism, suggesting that the carrier may be limited by the size of the substrate

  11. Control of octopus arm extension by a peripheral motor program.

    Science.gov (United States)

    Sumbre, G; Gutfreund, Y; Fiorito, G; Flash, T; Hochner, B

    2001-09-07

    For goal-directed arm movements, the nervous system generates a sequence of motor commands that bring the arm toward the target. Control of the octopus arm is especially complex because the arm can be moved in any direction, with a virtually infinite number of degrees of freedom. Here we show that arm extensions can be evoked mechanically or electrically in arms whose connection with the brain has been severed. These extensions show kinematic features that are almost identical to normal behavior, suggesting that the basic motor program for voluntary movement is embedded within the neural circuitry of the arm itself. Such peripheral motor programs represent considerable simplification in the motor control of this highly redundant appendage.

  12. Technology and the arms race

    International Nuclear Information System (INIS)

    MacKenzie, D.

    1988-01-01

    This article makes a review of the book Innovation and the Arms Race: How the United States and the Soviet Union Develop New Military Technologies written by Matthew Evangelista. For at least the last two decades, scholars have struggled to come to grips with the role of technological change in the arms race. Possible relationships between theories on technology and politics are examined. The contrasts between U.S. and Soviet approaches are highlighted

  13. Dedicated Carrier Deployment in Heterogeneous Networks with Inter-site Carrier Aggregation

    DEFF Research Database (Denmark)

    Wang, Hua; Rosa, Claudio; Pedersen, Klaus I.

    2013-01-01

    the macrocell or the picocell using simple cell range expansion (RE). Extensive system-level simulations have been conducted to investigate the performance gains that can be achieved with inter-site CA under different traffic models and user distributions. Results show that using inter-site CA between......) or picos with dedicated carrier deployment. Collaborative inter-site carrier aggregation (CA) is proposed in scenarios with macro+RRH deployment to make an efficient use of the fragmented spectrum from multiple cells. While in scenarios with macro+pico deployment, UEs can only connect to either...

  14. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Ricalde Anamaría E.

    1998-01-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  15. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Anamaría E. Ricalde

    1998-04-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  16. Optimizing Armed Forces Capabilities for Hybrid Warfare – New Challenge for Slovak Armed Forces

    Directory of Open Access Journals (Sweden)

    Peter PINDJÁK

    2015-09-01

    Full Text Available The paper deals with the optimization of military capabilities of the Slovak Armed Forces for conducting operations in a hybrid conflict, which represents one of the possible scenarios of irregular warfare. Whereas in the regular warfare adversaries intend to eliminate the centers of gravity of each other, most often command and control structures, in irregular conflicts, the center of gravity shifts towards the will and cognitive perception of the target population. Hybrid warfare comprises a thoroughly planned combination of conventional military approaches and kinetic operations with subversive, irregular activities, including information and cyber operations. These efforts are often accompanied by intensified activities of intelligence services, special operation forces, and even mercenary and other paramilitary groups. The development of irregular warfare capabilities within the Slovak Armed Forces will require a progressive transformation process that may turn the armed forces into a modern and adaptable element of power, capable of deployment in national and international crisis management operations.

  17. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  18. Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion

    Directory of Open Access Journals (Sweden)

    Yuchen Xu

    2018-04-01

    Full Text Available The micro-fabricated thin film electrode array (TFEA has been a promising design for cochlear implants (CIs because of its cost-effectiveness and fabrication precision. The latest polymer-based cochlear TFEAs have faced difficulties for cochlear insertion due to the lack of structural stiffness. To stiffen the TFEA, dissolvable stiffening materials, TFEAs with different structures, and TFEAs with commercial CIs as carriers have been invested. In this work, the concept of enhancing a Parylene TFEA with Kapton tape as a simpler carrier for cochlear insertion has been proved to be feasible. The bending stiffness of the Kapton-aided TFEA was characterized with an analytical model, a finite element model, and a cantilever bending experiment, respectively. While the Kapton tape increased the bending stiffness of the Parylene TFEA by 103 times, the 6-μm-thick TFEA with a similar Young’s modulus, as a polyimide, in turn significantly increased the bending stiffness of the 170-μm-thick Kapton carrier by 60%. This result indicated that even the TFEA is ultra-flexible and that its bending stiffness should not be neglected in the design or selection of its carrier.

  19. Carrier-carrier scattering in the gain dynamics of InxGa1-xAs/AlyGa1-yAs diode lasers

    DEFF Research Database (Denmark)

    Sanders, Gary D; Sun, C.-K.; Golubovic, B.

    1996-01-01

    Ultrafast optical nonlinearities in semiconductors play a central role in determining transient amplification and pulse-dependent gain saturation in diode lasers. Both carrier-phonon and carrier-carrier scattering are expected to determine the gain dynamics in these systems. We present a relaxation......-Dirac function where the chemical potential and temperature are self-consistently chosen so that both particle number and energy are conserved in the carrier-carrier scattering process. The relaxation approximation makes the problem an effective one-dimensional problem which can then be solved directly...

  20. Design of an ARM-based Automatic Rice-Selling Machine for Cafeterias

    Directory of Open Access Journals (Sweden)

    Zhiliang Kang

    2016-02-01

    Full Text Available To address the problems of low selling efficiency, poor sanitation conditions, labor-intensive requirement, and quick rice cooling speed in manual rice selling in cafeterias, especially in colleges and secondary schools, this paper presented an Advanced RISC Machines (ARM microprocessor-based rice-selling machine for cafeterias. The machines consisted of a funnel-shaped rice bin, a thermal insulation box, and a conveying and scattering mechanism. Moreover, this machine exerts fuzzy control over stepper motor rpm, and the motor drives the conveyor belt with a scraper to scatter rice, deliver it, and keep it warm. Apart from an external 4*4 keyboard, a point of sale (POS machine, an ARM process and a pressure sensor, the machine is also equipped with card swiping and weighting mechanisms to achieve functions of card swiping payment and precise measurement, respectively. In addition, detection of the right amount of rice and the alarm function are achieved using an ultrasonic sensor and a beeper, respectively. The presence of the rice container on the rice outlet is detected by an optoelectronic switch. Results show that this rice-selling machine achieves precise measurement, quick card swiping, fast rice selling, stable operation, and good rice heat preservation. Therefore, the mechanical design enables the machine to achieve its goals.

  1. Drift of nonequilibrium charge carriers in GaAs-crystals with traps in ultrasonic fields

    International Nuclear Information System (INIS)

    Zaveryukhina, N.N.; Zaveryukhin, B.N.; Zaveryukhina, E.B.

    2007-01-01

    Full text: The drift of nonequilibrium charge carriers in a semiconductor is one of the basic processes determining the efficiency of semiconductor photodetectors. Gallium arsenide possesses certain advantages to other semiconductors in this respect, which allow GaAs-photodetectors to be obtained which possess the maximum efficiency in comparison with all other systems. The purpose of this study was to deepen and expand our knowledge about the acoustic-drift processes in GaAs- crystals. As is known, the drift of nonequilibrium charge carriers in a semiconductor is determined either by external electric fields and/or by internal (built-in) electrostatic fields related to an impurity concentration gradient in the semiconductor. Gallium arsenide is a piezoelectric semiconductor with a structure possessing no center of symmetry. An electric field applied to such a crystal produces deformation of the crystal, and vice versa, any deformation of the crystal leads to the appearance of an induced electric field. Therefore, investigation of the effect of deformation on the drift of nonequilibrium charge carriers is a very important task. One of the possible straining factors is ultrasonic wave. Interaction of the charge carriers with ultrasonic waves in piezo-semiconductors is mediated by piezo exertion. Straining a semiconductor by an ultrasonic wave field gives rise to a force acting upon the charge carriers, which is proportional to the wave vector and the piezoelectric constant of the crystal. The physics of interaction between an ultrasonic wave and nonequilibrium charge carriers in GaAs, as well as in non-polar semiconductors (Si, Ge), consists in the energy and momentum exchange between the wave and the carriers. Besides the ultrasonic waves interact with the traps of carriers and devastate them. These both acoustic effects lead to rise of amplitude of signal of GaAs-photodetectors. (authors)

  2. 14 CFR 271.3 - Carrier subsidy need.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS GUIDELINES FOR SUBSIDIZING AIR CARRIERS PROVIDING ESSENTIAL AIR TRANSPORTATION § 271.3 Carrier subsidy need. In establishing the subsidy for an air carrier providing essential air service at an...

  3. Carbon: Hydrogen carrier or disappearing skeleton?

    International Nuclear Information System (INIS)

    De Jong, K.P.; Van Wechem, H.M.H.

    1994-01-01

    The use of liquid hydrocarbons as energy carriers implies the use of carbon as a carrier for hydrogen to facilitate hydrogen transport and storage. The current trend for liquid energy carriers used in the transport sector is to maximize the load of hydrogen on the carbon carrier. The recently developed Shell Middle Distillate Hydrogenation process for the manufacture of high quality diesel from aromatic refinery streams fits this picture. In the future, the hydrogen required to raise the product H/C ratio will be increasingly produced via gasification of large amounts of heavy residues. In the light of the strong preference towards using liquid fuels in the transport sector, the Shell Middle Distillate Synthesis process to convert natural gas into diesel of very high quality is discussed. Finally, a few comments on the use of hydrogen without a carbon carrier are made. Long lead times and the likelihood of producing the 'first' hydrogen from fossil fuel are highlighted. 13 figs., 6 tabs., 5 refs

  4. Gas turbine structural mounting arrangement between combustion gas duct annular chamber and turbine vane carrier

    Science.gov (United States)

    Wiebe, David J.; Charron, Richard C.; Morrison, Jay A.

    2016-10-18

    A gas turbine engine ducting arrangement (10), including: an annular chamber (14) configured to receive a plurality of discrete flows of combustion gases originating in respective can combustors and to deliver the discrete flows to a turbine inlet annulus, wherein the annular chamber includes an inner diameter (52) and an outer diameter (60); an outer diameter mounting arrangement (34) configured to permit relative radial movement and to prevent relative axial and circumferential movement between the outer diameter and a turbine vane carrier (20); and an inner diameter mounting arrangement (36) including a bracket (64) secured to the turbine vane carrier, wherein the bracket is configured to permit the inner diameter to move radially with the outer diameter and prevent axial deflection of the inner diameter with respect to the outer diameter.

  5. NMR-CT in muscular disorders. Muscle T/sub 1/ values in Duchenne muscular dystrophy carriers

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kiichiro; Nakano, Imaharu; Fukuda, Nobuo; Ikehira, Hiroo; Tateno, Yukio

    1987-02-01

    Proton NMR-CT (magnetic field strength 0.1 Tesla, resonant frequency 4.5 MHz) was performed in 10 normal females and 19 Duchenne muscular dystrophy (DMD) carriers. The mean age was 39 +- 12 years for the normal females and 42 +- 6 years for the DMD carriers. In DMD carriers, there were 4 definite, 4 probable, and 11 possible carriers. T/sub 1/ (spin-lattice relaxation time) image was obtained for a slice at the buttock, mid-thigh and calf levels respectively. T/sub 1/ values were measured for the medial portion of the gluteus maximus, the vastus lateralis of the quadriceps femoris, and the gastrocnemius. The bound water fraction (BWF) was calculated from Fullerton's equation based on the fast proton diffusion model. The following results were obtained: (1) In normal females, muscle T/sub 1/ value was highest in the gastrocnemius and lowest in the gluteus maximus. (2) In DMD carriers, T/sub 1/ values of the gluteus maximus and quadriceps femoris were significantly higher than those of the normal females. There was, however, no significant difference in T/sub 1/ value of the gastrocnemius between DMD carriers and normal females. (3) In DMD carriers, BWFs of the gluteus maximus and quadriceps femoris were significantly lower than those of the normal females. (4) In DMD carriers, no significant correlation was observed between the muscle T/sub 1/ values and the serum creatine phosphokinase values. Increased tissue water content in the lower parts of the body due to gravity is considered to be the primary cause of the high T/sub 1/ value in the gastrocnemius of normal females. The presence of the degenerating muscle fibers are presumed responsible for the high T/sub 1/ value and low BWF in the proximal muscles of DMD carriers.

  6. NMR-CT in muscular disorders. Muscle T/sub 1/ values in Duchenne muscular dystrophy carriers

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kiichiro; Nakano, Imaharu; Fukuda, Nobuo; Ikehira, Hiroo; Tateno, Yukio

    1987-02-01

    Proton NMR-CT (magnetic field strength 0.1 Tesla, resonant frequency 4.5 MHz) was performed in 10 normal females and 19 Duchenne muscular dystrophy (DMD) carriers. The mean age was 39 +- 12 years for the normal females and 42 +- 6 years for the DMD carriers. In DMD carriers, there were 4 definite, 4 probable, and 11 possible carriers. T/sub 1/ (spin-lattice relaxation time) image was obtained for a slice at the buttock, mid-thigh and calf levels respectively. T/sub 1/ values were measured for the medial portion of the gluteus maximus, the vastus lateralis of the quadriceps femoris, and the gastrocnemius. The bound water fraction (BWF) was calculated from Fullerton's equation based on the fast proton diffusion model. The following results were obtained: (1) In normal females, muscle T/sub 1/ value was highest in the gastrocnemius and lowest in the gluteus maximus. (2) In DMD carriers, T/sub 1/ values of the gluteus maximus and quadriceps femoris were significantly higher than those of the normal females. There was, however, no significant difference in T/sub 1/ value of the gastrocnemius between DMD carriers and normal females. (3) In DMD carriers, BWFs of the gluteus maximus and quadriceps femoris were significantly lower than those of the normal females. (4) In DMD carriers, no significant correlation was observed between the muscle T/sub 1/ values and the serum creatine phosphokinase values. Increased tissue water content in the lower parts of the body due to gravity is considered to be the primary cause of the high T/sub 1/ value in the gastrocnemius of normal females. The presence of the degenerating muscle fibers are presumed responsible for the high T/sub 1/ value and low BWF in the proximal muscles of DMD carriers.

  7. Simple model of the arms race

    International Nuclear Information System (INIS)

    Zane, L.I.

    1982-01-01

    A simple model of a two-party arms race is developed based on the principle that the race will continue so long as either side can unleash an effective first strike against the other side. The model is used to examine how secrecy, the ABM, MIRV-ing, and an MX system affect the arms race

  8. Kinematic decomposition and classification of octopus arm movements

    Directory of Open Access Journals (Sweden)

    Ido eZelman

    2013-05-01

    Full Text Available The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  9. ATLAS software stack on ARM64

    CERN Document Server

    Smith, Joshua Wyatt; The ATLAS collaboration

    2016-01-01

    The ATLAS experiment explores new hardware and software platforms that, in the future, may be more suited to its data intensive workloads. One such alternative hardware platform is the ARM architecture, which is designed to be extremely power efficient and is found in most smartphones and tablets. CERN openlab recently installed a small cluster of ARM 64-bit evaluation prototype servers. Each server is based on a single-socket ARM 64-bit system on a chip, with 32 Cortex-A57 cores. In total, each server has 128 GB RAM connected with four fast memory channels. This paper reports on the port of the ATLAS software stack onto these new prototype ARM64 servers. This included building the "external" packages that the ATLAS software relies on. Patches were needed to introduce this new architecture into the build as well as patches that correct for platform specific code that caused failures on non-x86 architectures. These patches were applied such that porting to further platforms will need no or only very little adj...

  10. Automated production of no carrier added holmium-166

    International Nuclear Information System (INIS)

    Izard, M.E.; Dadchova, E.

    1996-01-01

    Full text: An automated system has been developed to produce no carrier added 166 Ho from the decay of 166 Dy produced by neutron activation of 164 Dy 2 O 3 . Targets consisting of 5-10 mg of 164 Dy 2 O 3 are irradiated in HIFAR at 5 x 10 13 n.s -1 .cm -2 for 12h then allowed to cool for 2 days. The irradiation can is then transferred to the automated system located in a 'hot' cell in the radiopharmaceutical research building. A two dimension robotic arm encompassing a grab and motorized screwdriver is used to open the irradiation can. A second arm carrying a teflon tube introduces 9M HCI into the can to dissolve the target. A second tube carries the dissolved target via a peristaltic pump to a heated vial where it is evaporated to dryness under a flow of N 2 . A Peltier cooled trap is used to prevent release of HCl fumes into the cell. A motorized syringe pump dispenses 1 mL of 0.1 M HNO 3 to redissolve the digest which is then transferred by peristaltic pump via a hollow fibre filter and auto injector into an Aminex- A5 HPLC column. 166 Dy is eluted from the column in 0.132 M α-HIBA into a heated cyclone flask and evaporated to dryness under a stream of N 2 heated to about 50 deg C. After two days the evaporated Dy/ 166 Ho digest is dissolved in another 1 mL of 0.1 M HNO 3 and injected onto the HPLC column. 166 Ho is collected in 20-25 mL of α-HIBA and evaporated to dryness as before at about 400 C to ensure complete decomposition of the α-HIBA. The product is finally dissolved in about I mL of 0.1 M HCI and pumped through a 0.22 μM filter to a product vial

  11. Arms control, nonproliferation, and US national security

    International Nuclear Information System (INIS)

    Pilat, J.F.

    1985-01-01

    The continuation of the arms race and the failure of arms control and disarmament negotiations lend support to the belief that US and Soviet power, prestige, and security depend upon nuclear weapons. Therefore, the argument goes, the non-nuclear-weapon states (particularly those that are not allied with nuclear-weapon states and do not share their nuclear shield) may conclude that they would be well served by possession of these weapons. In this sense, the failure of nuclear arms reductions could create incentives for further proliferation

  12. Motor carrier evaluation program plan

    International Nuclear Information System (INIS)

    Portsmouth, J.H.; Maxwell, J.E.; Boness, G.O.; Rice, L.E.

    1991-04-01

    The US Department of Energy (DOE) Transportation Management Program (TMP) has established a program to assist the DOE field offices and their contractors in evaluating the motor carriers used to transport DOE-owned hazardous and radioactive materials. This program was initiated to provide the DOE field offices with the tools necessary to help ensure, during this period of motor carrier deregulation, that only highly qualified carriers transport radioactive and hazardous commodities for the DOE. This program will assist DOE in maintaining their excellent performance record in the safe transportation of hazardous commodities. The program was also developed in response to public concern surrounding the transportation of hazardous materials. Representatives of other federal agencies, states, and tribal governments, as well as the news media, have expressed concern about the selection and qualification of carriers engaged in the transportation of Highway Route-Controlled Quantities (HRCQ) and Truckload (TL) quantities of radioactive material for the DOE. 8 refs

  13. Radionuclide carrier

    International Nuclear Information System (INIS)

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  14. Carrier Screening

    Science.gov (United States)

    ... How accurate is carrier screening? No test is perfect. In a small number of cases, test results ... in which an egg is removed from a woman’s ovary, fertilized in a laboratory with the man’s ...

  15. To Arm or Not to Arm: The Case Against Arming Vietnam and the Philippines

    Science.gov (United States)

    2015-04-13

    designed to allay 9 Leaf (accessed Oct 24, 2014). 10 Ankit Panda , “What to Expect if the U.S. Lifts...their animated populations. Despite the rhetoric, no ideology or nation is monolithic, thus opportunities exist to improve the U.S.-Sino...Joint Forces Quarterly 2 (2014): 76-80. Panda , Ankit. “What to Expect if the U.S. Lifts Its Vietnam Arms Embargo.” The Diplomat. September 29

  16. Inter-Arm Blood Pressure Difference in Hospitalized Elderly Patients Is Not Associated With Excess Mortality.

    Science.gov (United States)

    Weiss, Avraham; Grossman, Alon; Beloosesky, Yichayaou; Koren-Morag, Nira; Green, Hefziba; Grossman, Ehud

    2015-10-01

    Inter-arm blood pressure difference (IAD) has been found to be associated with cardiovascular mortality. Its clinical significance and association with mortality in the elderly is not well defined. This study evaluated the association of IAD with mortality in a cohort of hospitalized elderly individuals. Blood pressure (BP) was measured simultaneously in both arms in elderly individuals (older than 65 years) hospitalized in a geriatric ward from October 2012 to July 2014. During the study period, 445 patients, mostly women (54.8%) with a mean age of 85±5 years, were recruited. Systolic and diastolic IAD were >10 mm Hg in 102 (22.9%) and 76 (17.1%) patients, respectively. Patients were followed for an average of 342±201 days. During follow-up, 102 patients (22.9%) died. Mortality was not associated with systolic or diastolic IAD. It is therefore questionable whether BP should be routinely measured in both arms in the elderly. © 2015 Wiley Periodicals, Inc.

  17. Pyrolysis Characteristics of Corn Stalk with Solid Heat Carrier

    Directory of Open Access Journals (Sweden)

    Min Guo

    2015-05-01

    Full Text Available Pyrolysis of corn stalk with a solid heat carrier was studied under temperatures ranging from 430 to 620 °C. The solid heat carrier used was high-temperature ash from a CFB boiler. The yields of three products and their characteristics were investigated. Moreover, the distributions of sulfur and nitrogen in the products were determined. The results indicate that with increasing temperature, the char yield decreased, gas yield increased, and calorific value of the gas increased from 10.13 to 16.65 MJ/m3. The yield of bio-oil reached a maximum, 14.24 wt.%, at 510 °C. Light-oil in the bio-oil accounted for more than 69.12 wt.%. The elemental composition of the char and char ash were analyzed. The distribution of sulfur and nitrogen in the char decreased to 60.44 and 46.52 wt.%, respectively, depending on the raw materials used. These results provide basic data for the possible industrial application of corn stalk.

  18. Isotropy of an Upper Limb Exoskeleton and the Kinematics and Dynamics of the Human Arm

    Directory of Open Access Journals (Sweden)

    Joel C. Perry

    2009-01-01

    Full Text Available The integration of human and robot into a single system offers remarkable opportunities for a new generation of assistive technology. Despite the recent prominence of upper limb exoskeletons in assistive applications, the human arm kinematics and dynamics are usually described in single or multiple arm movements that are not associated with any concrete activity of daily living (ADL. Moreover, the design of an exoskeleton, which is physically linked to the human body, must have a workspace that matches as close as possible with the workspace of the human body, while at the same time avoid singular configurations of the exoskeleton within the human workspace. The aims of the research reported in this manuscript are (1 to study the kinematics and the dynamics of the human arm during daily activities in a free and unconstrained environment, (2 to study the manipulability (isotropy of a 7-degree-of-freedom (DOF-powered exoskeleton arm given the kinematics and the dynamics of the human arm in ADLs. Kinematic data of the upper limb were acquired with a motion capture system while performing 24 daily activities from six subjects. Utilising a 7-DOF model of the human arm, the equations of motion were used to calculate joint torques from measured kinematics. In addition, the exoskeleton isotropy was calculated and mapped with respect to the spacial distribution of the human arm configurations during the 24 daily activities. The results indicate that the kinematic joint distributions representing all 24 actions appear normally distributed except for elbow flexion–extension with the emergence of three modal centres. Velocity and acceleration components of joint torque distributions were normally distributed about 0 Nm, whereas gravitational component distributions varied with joint. Additionally, velocity effects were found to contribute only 1/100th of the total joint torque, whereas acceleration components contribute 1/10th of the total torque at the

  19. Stellar complexes in spiral arms of galaxies

    Science.gov (United States)

    Efremov, Yu. N.

    The history of the introduction and development of the star complexes conception is briefly described. These large groups of stars were picked out and named as such ones in our Galaxy with argumentation and evidence for their physical unity (using the Cepheid variables the distances and ages of which are easy determined from their periods); anyway earlier the complexes were noted along the spiral arms of the Andromeda galaxy, but were not recognized as a new kind of star group. The chains of complexes along the spiral arms are observed quite rarely; their origin is explained by magneto- gravitational or purely gravitational instability developing along the arm. It is not clear why these chains are quite a rare phenomenon - and more so why sometimes the regular chain of complexes are observed in one arm only. Probably intergalactic magnetic field participated in formation of such chains. Apart from the complexes located along the arms, there are isolated giant complexes known (up to 700 pc in diameter) which look like super-gigantic but rather rarefied globular clusters. Until now only two of these formations are studied, in NGC 6946 and M51.

  20. Production of ammonia from plasma-catalytic decomposition of urea: Effects of carrier gas composition.

    Science.gov (United States)

    Fan, Xing; Li, Jian; Qiu, Danqi; Zhu, Tianle

    2018-04-01

    Effects of carrier gas composition (N 2 /air) on NH 3 production, energy efficiency regarding NH 3 production and byproducts formation from plasma-catalytic decomposition of urea were systematically investigated using an Al 2 O 3 -packed dielectric barrier discharge (DBD) reactor at room temperature. Results show that the presence of O 2 in the carrier gas accelerates the conversion of urea but leads to less generation of NH 3 . The final yield of NH 3 in the gas phase decreased from 70.5%, 78.7%, 66.6% and 67.2% to 54.1%, 51.7%, 49.6% and 53.4% for applied voltages of 17, 19, 21 and 23kV, respectively when air was used as the carrier gas instead of N 2 . From the viewpoint of energy savings, however, air carrier gas is better than N 2 due to reduced energy consumption and increased energy efficiency for decomposition of a fixed amount of urea. Carrier gas composition has little influence on the major decomposition pathways of urea under the synergetic effects of plasma and Al 2 O 3 catalyst to give NH 3 and CO 2 as the main products. Compared to a small amount of N 2 O formed with N 2 as the carrier gas, however, more byproducts including N 2 O and NO 2 in the gas phase and NH 4 NO 3 in solid deposits were produced with air as the carrier gas, probably due to the unproductive consumption of NH 3 , the possible intermediate HNCO and even urea by the abundant active oxygen species and nitrogen oxides generated in air-DBD plasma. Copyright © 2017. Published by Elsevier B.V.

  1. Charge-carrier mobilities in disordered semiconducting polymers: effects of carrier density and electric field [refereed

    NARCIS (Netherlands)

    Meisel, K.D.; Pasveer, W.F.; Cottaar, J.; Tanase, C.; Coehoorn, R.; Bobbert, P.A.; Blom, P.W.M.; Leeuw, de D.M.; Michels, M.A.J.

    2006-01-01

    We model charge transport in disordered semiconducting polymers by hopping of charge carriers on a square lattice of sites with Gaussian on-site energy disorder, using Fermi-Dirac statistics. From numerically exact solns. of the Master equation, we study the dependence of the charge-carrier mobility

  2. Design and development of the first exoskeletal garment to enhance arm mobility for children with movement impairments.

    Science.gov (United States)

    Hall, Martha L; Lobo, Michele A

    2017-05-25

    Children with a variety of diagnoses have impairments that limit their arm function. Despite the fact that arm function is important for early learning and activities of daily living, there are few tools to assist movement for these children, and existing devices have challenges related to cost, accessibility, comfort, and aesthetics. In this article, we describe the design process and development of the first garment-based exoskeleton to assist arm movement in young children with movement impairments: the Playskin Lift TM . We outline our design process, which contrasts with the traditional medical model in that it is interdisciplinary, user-centered, and addresses the broad needs of users, rather than device function alone. Then we report the results of field-testing with the initial prototype with respect to our design metrics on a toddler with significant bilateral arm movement impairments. Finally, we summarize our ongoing development aimed at increasing comfort, aesthetics, and accessibility of the garment. The interdisciplinary, user-centered approach to assistive technology design presented here can result in innovative and impactful design solutions that translate to the real world.

  3. Family paracentric inversion of the short arm of chromosome X (Xp21.2p11.23 and connection with autism spectrum disorders

    Directory of Open Access Journals (Sweden)

    Pejović-Milovančević Milica

    2012-01-01

    Full Text Available Introduction. Autism spectrum disorders (ASDs are a group of complex pervasive developmental disorders characterized by impairments in communication, social interaction and behavior. In most cases autism is caused by a combination of genetic factors and environmental risk factors. In 10% to 20% of cases it has been shown that the cause of ASD is genetic. Case Outline. We are describing a 2-year-old boy who was referred to genetic counseling because of speech delay and certain autism-like behavior. By cytogenetic analysis the karyotype 46, inv(X,Y was obtained. The boy was a carrier of a paracentric inversion of the short arm of the chromosome X. After cytogenetic analysis of parental blood, it was detected that mother was a carrier of identical aberration, but had no clinical signs. The method of fluorescent in situ hybridization (FISH yielded the precise breakpoint in the region (p21.2p11.23. Mother and son were carriers of identical X chromosome. Conclusion. Breakpoints are located in the regions that have already been linked to autism, which indicates that the positional effect of the gene could have been a possible cause of the patient’s genotype. In addition to positional effects, in order to better understand the etiology of autism other genetic and environmental factors should be always taken into consideration. [Projekat Ministarstva nauke Republike Srbije, br. ON175013

  4. Low-voltage and high-efficiency white organic light emitting devices with carrier balance

    International Nuclear Information System (INIS)

    Wei Fuxiang; Huang, Y.; Fang, L.

    2010-01-01

    White organic light emitting devices with the structure of ITO/m-MTDATA:x%4F-TCNQ/NPB/TBADN:EBDP:DCJTB/Bphen:Liq/LiF/Al have been demonstrated in this paper. High-mobility m-MTDATA:4F-TCNQ is added into the region between ITO and NBP to increase hole injection and transport. The high-mobility Bphen:Liq layer is added into the region between cathode and emission layers to lower cathode barrier and facilitate carrier injection. In the meanwhile, an effective carrier balance (number of holes is equal to number of electrons) between holes and electrons is considered to be one of the most important factors for improving OLEDs. During the experiment, by modulating the doping concentration of 4F-TCNQ, we can control hole injection and transport to make the carriers reach a high-level balance. The maximum current efficiency and power efficiency of devices were 9.3 cd/A and 4.6 lm/A, respectively.

  5. Changing patterns of arms transfers

    International Nuclear Information System (INIS)

    Wulf, H.

    1998-01-01

    Three factors in the international system have been of importance for the trade of arms: the role of the main actors on the supply side and since 1970 on the demand side, the permanently increasing importance of economics, and the balance trade, industrial capacity and jobs in supplier countries and purchasing power of potential importers. Two political events in 1991 had lasting effect on the development of the trade in arms: the dissolution of Soviet Union and the Gulf War

  6. Driving pockels cells in multi-arm lasers

    International Nuclear Information System (INIS)

    Carder, B.M.

    1978-01-01

    This paper describes the method used to drive Pockels cells on the 20-arm Shiva laser for inertial confinement fusion research at the Lawrence Livermore Laboratory. Shiva became operational last fall, and has just completed a series of 20-arm target shots. It uses two pockels cell gates in each laser arm for suppression of amplified spontaneous emission (ASE) that can damage or destroy the target before the main pulse arrives. Two additional Pockels cells are used in the preamplification stages, so that a total of 42 cells must be driven by the pulser system

  7. Assessment of workers' exposure to hand-arm and whole body vibration in one of the furniture industries in east of Tehran

    Directory of Open Access Journals (Sweden)

    Ramazan Mirzaei

    2015-01-01

    Full Text Available Workers in wood industry are exposed to vibration and its damages. The purpose of this study was to evaluate exposure to hand-arm and whole body vibration in the wood industry. In this study, the parameters of whole body and hand-arm vibrations such as effective acceleration, overall equivalent acceleration, Vibration Dose Value and crest factor were studied on two Thicknessing planes, two sliding panel saw machines, two orbital sander, and three operators of perforate procedure. Assessments were done by the use of an oscillator and an analyzer of Svantak Co. Evaluating Hand-arm and whole body vibrations were conducted based on ISO 5349-1, ISO 5349-2 and ISO 2631-1 standards, respectively, and the findings/ the evaluated data were analyzed. The mean amount of daily exposure to hand-arm vibration (RMS in Thicknessing plane, Orbital Sander and Sliding panel saw machine operators are respectively 5.56, 5.49 and 3.37 m/s2 . In addition, the average crest factor of the 3 jobs is higher than 6. Mean of daily Exposure to whole body vibration in 3 machine operators of Thicknessing plane, perforate procedure and Sliding panel saw is respectively, 0.28, 0.24 and 0.17 meters per square second. The crest factor for all the exposures was to be less than 6 and the mean of the calculated daily vibration dose equaled 5.83 with the standard deviation of 0.87( m⁄s^1.75 . In further measured situations, exposure to hand-arm vibration is more than the standard level, so engineering and management measures are required to reduce the amount of exposure and support the health of the operators and the equipment.

  8. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  9. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  10. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  11. Molecular clouds in the Carina arm - the largest objects, associated regions of star formation, and the Carina arm in the Galaxy

    International Nuclear Information System (INIS)

    Grabelsky, D.A.; Cohen, R.S.; Bronfman, L.; Thaddeus, P.

    1988-01-01

    The Columbia CO survey of the southern Galactic plane is used to identify giant molecular clouds and cloud complexes in the Vela-Carina-Centaurus section of the Galaxy. Twenty-seven giant molecular clouds between l = 270 and 300 deg are catalogued and their heliocentric distances given. In addition, 16 clouds at l greater than 300 deg beyond the solar circle extend the catalog to include the very distant portion of the Carina arm. The most massive clouds in the catalog trace the Carina arm over 23 kpc in the plane of the Galaxy. The average mass of these objects is 1.4 x 10 to the 6th solar, and their average spacing along the arm is 700 pc. The composite distribution projected onto the Galactic plane of the largest molecular clouds in the Carina arm and of similarly massive clouds in the first and second quadrants strongly suggests that the Carina and Sagittarius arms form a single spiral arm about 40 kpc in length wrapping two-thirds of the way around the Galaxy. Descriptions of each cloud, including identification of associated star-forming regions, are presented in an appendix. 76 references

  12. Carrier dynamics in graphene. Ultrafast many-particle phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Malic, E.; Brem, S.; Jago, R. [Department of Physics, Chalmers University of Technology, Goeteborg (Sweden); Winzer, T.; Wendler, F.; Knorr, A. [Institut fuer Theoretische Physik, Technische Universitaet Berlin (Germany); Mittendorff, M.; Koenig-Otto, J.C.; Schneider, H.; Helm, M.; Winnerl, S. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Ploetzing, T.; Neumaier, D. [Advanced Microelectronic Center Aachen, AMO GmbH, Aachen (Germany)

    2017-11-15

    Graphene is an ideal material to study fundamental Coulomb- and phonon-induced carrier scattering processes. Its remarkable gapless and linear band structure opens up new carrier relaxation channels. In particular, Auger scattering bridging the valence and the conduction band changes the number of charge carriers and gives rise to a significant carrier multiplication - an ultrafast many-particle phenomenon that is promising for the design of highly efficient photodetectors. Furthermore, the vanishing density of states at the Dirac point combined with ultrafast phonon-induced intraband scattering results in an accumulation of carriers and a population inversion suggesting the design of graphene-based terahertz lasers. Here, we review our work on the ultrafast carrier dynamics in graphene and Landau-quantized graphene is presented providing a microscopic view on the appearance of carrier multiplication and population inversion. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Solid state cloaking for electrical charge carrier mobility control

    Science.gov (United States)

    Zebarjadi, Mona; Liao, Bolin; Esfarjani, Keivan; Chen, Gang

    2015-07-07

    An electrical mobility-controlled material includes a solid state host material having a controllable Fermi energy level and electrical charge carriers with a charge carrier mobility. At least one Fermi level energy at which a peak in charge carrier mobility is to occur is prespecified for the host material. A plurality of particles are distributed in the host material, with at least one particle disposed with an effective mass and a radius that minimize scattering of the electrical charge carriers for the at least one prespecified Fermi level energy of peak charge carrier mobility. The minimized scattering of electrical charge carriers produces the peak charge carrier mobility only at the at least one prespecified Fermi level energy, set by the particle effective mass and radius, the charge carrier mobility being less than the peak charge carrier mobility at Fermi level energies other than the at least one prespecified Fermi level energy.

  14. Electrothermal modeling, fabrication and analysis of low-power consumption thermal actuator with buckling arm

    KAUST Repository

    So, Hongyun

    2013-10-31

    © 2013, Springer-Verlag Berlin Heidelberg. This paper reports on a novel thermal actuator with sub-micron metallic structures and a buckling arm to operate with low voltages and to generate very large deflections, respectively. A lumped electrothermal model and analysis were also developed to validate the mechanical design and easily predict the temperature distribution along arms of the sub-micron actuator. The actuator was fabricated via the combination of electron beam lithography to form actuator arms with a minimum feature size of 200 nm and lift-off process to deposit a high aspect ratio nickel structure. Reproducible displacements of up to 1.9 μm at the tip were observed up to 250 mV under confocal microscope. The experimentally measured deflection values and theoretically calculated temperature distribution by the developed model were compared with finite element analysis results and they were in good agreement. This study shows a promising approach to develop more sophisticated nano actuators required larger deflections for manipulation of sub-micron scale objects with low-power consumption.

  15. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Lab. (ANL), Argonne, IL (United States); Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty

  16. The variability of ankle-arm blood pressure difference and ankle-brachial index in treated hypertensive patients.

    Science.gov (United States)

    Cao, Kaiwu; Xu, Jinsong; Sun, Hanjun; Li, Ping; Li, Juxiang; Cheng, Xiaoshu; Su, Hai

    2014-10-01

    The purpose of this study was to investigate whether ankle-arm blood pressure (BP) difference (An-a) and ankle-brachial index (ABI) are consistent in treated hypertensive patients with obvious BP variation. This study enrolled 414 hypertensive patients (200 males; mean age, 61.3 ± 13.3 years) admitted to our hospital. BP of four limbs was simultaneously measured using four automatic BP measurement devices on the day of admission, and three and six day after admission. The An-a differences on systolic BP (SBP), diastolic BP (DBP), mean artery pressure (MAP), and pulse pressure (PP) in both sides were calculated, respectively. The relative decrease amplitude (RDA) of BP was calculated using the formula: RDA = (BP1 - BPn)/BP1. The ABI of the right side was calculated. From the first to the third measurement, arm SBP and DBP levels of both arms significantly decreased (right arm: SBP: 163.7 ± 18.4, 147.7 ± 15.3 vs. 135.4 ± 11.7 mm Hg; P differences on SBP, DBP, PP, and MAP are generally consistent, but sABI is associated with underlying SBP levels.

  17. Biotinylated liposomes as potential carriers for the oral delivery of insulin.

    Science.gov (United States)

    Zhang, Xingwang; Qi, Jianping; Lu, Yi; He, Wei; Li, Xiaoyang; Wu, Wei

    2014-01-01

    This study aimed to explore biotinylated liposomes (BLPs) as novel carriers to enhance the oral delivery of insulin. Biotinylation was achieved by incorporating biotin-conjugated phospholipids into the liposome membranes. A significant hypoglycemic effect and enhanced absorption were observed after treating diabetic rats with the BLPs with a relative bioavailability of 12.09% and 8.23%, based on the measurement of the pharmacologic effect and the blood insulin level, respectively; this achieved bioavailability was approximately double that of conventional liposomes. The significance of the biotinylation was confirmed by the facilitated absorption of the BLPs through receptor-mediated endocytosis, as well as by the improved physical stability of the liposomes. Increased cellular uptake and quick gastrointestinal transport further verified the ability of the BLPs to enhance absorption. These results provide a proof of concept that BLPs can be used as potential carriers for the oral delivery of insulin. Diabetes remains a major source of mortality in the Western world, and advances in its management are expected to have substantial socioeconomic impact. In this paper, biotinylated liposomes were utilized as carriers of insulin for local delivery, demonstrating the feasibility of this approach in a rat model. © 2014.

  18. Putting the Glare of Publicity on International Arms Sales.

    Science.gov (United States)

    Hartman, William

    1992-01-01

    Reports on a United Nations committee recommendation that the Security Council establish a universal register of arms. Suggests that such a register would limit the destabilizing influence of major arms sales on developing nations. Argues that visibility of arms sales may help reduce their number. (DK)

  19. Duchenne muscular dystrophy carriers

    International Nuclear Information System (INIS)

    Matsumura, K.; Nakano, I.

    1989-01-01

    By means of magnetic resonance imaging (MRI), the proton spin-lattice relaxation times (T1 values) of the skeletal muscles were measured in Duchenne muscular dystrophy (DMD) carriers and normal controls. The bound water fraction (BWF) was calculated from the T1 values obtained, according to the fast proton diffusion model. In the DMD carriers, T1 values of the gluteus maximus and quadriceps femoris muscles were significantly higher, and BWFs of these muscles were significantly lower than in normal control. Degenerative muscular changes accompanied by interstitial edema were presumed responsible for this abnormality. No correlation was observed between the muscle T1 and serum creatine kinase values. The present study showed that MRI could be a useful method for studying the dynamic state of water in both normal and pathological skeletal muscles. Its possible utility for DMD carrier detection was discussed briefly. (orig.)

  20. The Role of Ethics in International Arms Transfers

    Science.gov (United States)

    2016-06-01

    i THE ROLE OF ETHICS IN INTERNATIONAL ARMS TRANSFERS BY MAJOR ROB ARNETT A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF...War’s Ends” provided the intellectual spark to explore the topic of ethics in international arms sales. Additionally, Dr. Murphy was kind enough to... ethics in American arms transfer policy to determine whether the Just War tradition’s jus ad bellum framework can help policymakers through a complex

  1. MPL-net at ARM Sites

    Science.gov (United States)

    Spinhirne, J. D.; Welton, E. J.; Campbell, J. R.; Berkoff, T. A.; Starr, David OC. (Technical Monitor)

    2002-01-01

    The NASA MPL-net project goal is consistent data products of the vertical distribution of clouds and aerosol from globally distributed lidar observation sites. The four ARM micro pulse lidars are a basis of the network to consist of over twelve sites. The science objective is ground truth for global satellite retrievals and accurate vertical distribution information in combination with surface radiation measurements for aerosol and cloud models. The project involves improvement in instruments and data processing and cooperation with ARM and other partners.

  2. Relaxation of a kinetic hole due to carrier-carrier scattering in multisubband single-quantum-well semiconductors

    DEFF Research Database (Denmark)

    Dery, H.; Tromborg, Bjarne; Eisenstein, G.

    2003-01-01

    We describe a theoretical model for carrier-carrier scattering in an inverted semiconductor quantum well structure using a multisubband diagram. The model includes all possible nonvanishing interaction terms within the static screening approximation, and it enables one to calculate accurately...

  3. WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

    International Nuclear Information System (INIS)

    Ritschl, L; Kachelriess, M; Kuntz, J

    2015-01-01

    Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging

  4. Controlling of carrier movement on gamma irradiator ISG-500

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2010-01-01

    Gamma irradiator ISG-500 is being designed. One of the design objects in the gamma irradiator is carrier movement and its controlling. Many possibilities of carrier movements can be implemented in the set-up design, such as using discrete or continuous mode. In this paper, selected discrete carriers movement and their controlling for the basic-design of the ISG-500 will be discussed. Nine stopper locations for nineteen carriers in operation will be controlled their carriers movement so that the movements have maximum positive transient load (increasing load) two carriers only. The controlling of the movement uses a train of pulses counting system as a one-dimension coordinate reference of a point on the rotated chain pulling the carrier. Every stopper location has a specific counting number in which will be used by the controlling system to let the carrier in the stopper location moving. By this movement, it is expected to prolong the life-time of the in use carrier mover motor. (author)

  5. The NuSTAR Hard X-Ray Survey of the Norma Arm Region

    DEFF Research Database (Denmark)

    Fornasini, Francesca M.; Tomsick, John A.; Hong, JaeSub

    2017-01-01

    We present a catalog of hard X-ray sources in a square-degree region surveyed by the Nuclear Spectroscopic Telescope Array (NuSTAR) in the direction of the Norma spiral arm. This survey has a total exposure time of 1.7 Ms, and the typical and maximum exposure depths are 50 ks and 1 Ms, respectively...... model with kT ≈ 15 keV, as observed for the CV candidates....

  6. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Safeguarding arms control

    International Nuclear Information System (INIS)

    Flanagan, S.J.

    1988-01-01

    This essay reviews the evolution of various safeguards concepts associated with U.S. Soviet arms control negotiations over the past twenty-five years. It explore in some detail the origins, nature, and effectiveness of the safeguards packages associated with six agreements: the Limited Test Ban Treaty (1963), the SALT I Interim Agreement (1972), the Anti-Ballistic Missile (ABM) Treaty (1972), the Threshold Test Ban Treaty (1974), the Peaceful Nuclear Explosions Treaty (1976) and the SALT II Treaty (1979). Finally, the implications of this historical record for developing future nuclear and conventional arms control accords and for shoring up existing pacts, such as the ABM Treaty, are assessed with a view towards practicable prescriptions for Western policymakers. The treaty eliminating intermediate-range nuclear forces (INF) incorporates several verification safeguards, and it is very likely that analogous measures would be attached to any accord constraining conventional forces in Europe

  8. Spiral arm amplitude variations and pattern speeds in the grand design galaxies M51, M81, and M100

    International Nuclear Information System (INIS)

    Elmegreen, B.G.; Seiden, P.E.; Elmegreen, D.M.

    1989-01-01

    In the modal theory of galactic spiral structure, the amplitude of a prominent two-arm spiral pattern should oscillate slightly with galactocentric distance because of an interference between the outward and inward propagating waves. In the stellar dynamical theory, the spiral arm amplitudes should oscillate because of differential crowding near and between wave-orbit resonances. Two and three cycles of such oscillations have been found in computer-enhanced images at B and I passbands of the grand design galaxies M81 and M100, respectively, and what is probably one cycle of such an amplitude variation in M51. These three galaxies are the most symmetric and global of the two-arm spirals in the near-IR survey of Elmegreen (1981), so the occurrence of such spiral amplitude oscillations could be common among galaxies of this type. The positions of the features discussed are used to suggest possible arm pattern speeds. 23 refs

  9. Synthesis of 'no-carrier-added' sup(11)C-labelled nitrosoureas

    Energy Technology Data Exchange (ETDEWEB)

    Diksic, M.; Farrokhzad, S.; Yamamoto, Y.L.; Feindel, W. (Montreal Neurological Inst., Quebec (Canada))

    1985-03-01

    Syntheses for sup(11)C-labelled chemotherapeutic drugs CCNU, BFNU and CFNU (analogs of BCNU) as well as an improved synthesis for sup(11)C-BCNU are described. The procedures for the separation of dual isomers in the case of sup(11)C-labelled CCNU and CFNU are discussed. The specific activity of these 'no-carrier-added' radiopharmaceuticals was approximately 10sup(4) lower than expected for a carrier-free product. The syntheses were normally finished 20-25 min after the end of the collection of sup(11)C-COClsub(2). Chemical and radiochemical purity of the final products as determined by HPLC and TLRC, respectively, was at least 98%. The syntheses yielded 10-25 mCi of nitrosourea ready for use in PET studies.

  10. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  11. A software radio platform based on ARM and FPGA

    Directory of Open Access Journals (Sweden)

    Yang Xin.

    2016-01-01

    Full Text Available The rapid rise in computational performance offered by computer systems has greatly increased the number of practical software radio applications. A scheme presented in this paper is a software radio platform based on ARM and FPGA. FPGA works as the coprocessor together with the ARM, which serves as the core processor. ARM is used for digital signal processing and real-time data transmission, and FPGA is used for synchronous timing control and serial-parallel conversion. A SPI driver for real-time data transmission between ARM and FPGA under ARM-Linux system is provided. By adopting modular design, the software radio platform is capable of implementing wireless communication functions and satisfies the requirements of real-time signal processing platform for high security and broad applicability.

  12. Biomechanical differences of arm swing countermovement jumps on sand and rigid surface performed by elite beach volleyball players.

    Science.gov (United States)

    Giatsis, George; Panoutsakopoulos, Vassilios; Kollias, Iraklis A

    2018-05-01

    The purpose of this study was to investigate the possible arm swing effect on the biomechanical parameters of vertical counter movement jump due to differences of the compliance of the take-off surface. Fifteen elite male beach-volleyball players (26.2 ± 5.9 years; 1.87 ± 0.05 m; 83.4 ± 6.0 kg; mean ± standard deviation, respectively) performed counter movement jumps on sand and on a rigid surface with and without an arm swing. Results showed significant (p volleyball.

  13. Natural Resource Extraction, Armed Violence, and Environmental Degradation.

    Science.gov (United States)

    Downey, Liam; Bonds, Eric; Clark, Katherine

    2010-12-01

    The goal of this article is to demonstrate that environmental sociologists cannot fully explain the relationship between humans and the natural world without theorizing a link between natural resource extraction, armed violence, and environmental degradation. The authors begin by arguing that armed violence is one of several overlapping mechanisms that provide powerful actors with the means to (a) prevail over others in conflicts over natural resources and (b) ensure that natural resources critical to industrial production and state power continue to be extracted and sold in sufficient quantities to promote capital accumulation, state power, and ecological unequal exchange. The authors then identify 10 minerals that are critical to the functioning of the U.S. economy and/or military and demonstrate that the extraction of these minerals often involves the use of armed violence. They further demonstrate that armed violence is associated with the activities of the world's three largest mining companies, with African mines that receive World Bank funding, and with petroleum and rainforest timber extraction. The authors conclude that the natural resource base on which industrial societies stand is constructed in large part through the use and threatened use of armed violence. As a result, armed violence plays a critical role in fostering environmental degradation and ecological unequal exchange.

  14. US-Russian relations: the arms control agenda

    International Nuclear Information System (INIS)

    Potter, W.

    2001-01-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  15. US-Russian relations: the arms control agenda

    Energy Technology Data Exchange (ETDEWEB)

    Potter, W

    2001-07-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  16. Histidine-lysine peptides as carriers of nucleic acids.

    Science.gov (United States)

    Leng, Qixin; Goldgeier, Lisa; Zhu, Jingsong; Cambell, Patricia; Ambulos, Nicholas; Mixson, A James

    2007-03-01

    With their biodegradability and diversity of permutations, peptides have significant potential as carriers of nucleic acids. This review will focus on the sequence and branching patterns of peptide carriers composed primarily of histidines and lysines. While lysines within peptides are important for binding to the negatively charged phosphates, histidines are critical for endosomal lysis enabling nucleic acids to reach the cytosol. Histidine-lysine (HK) polymers by either covalent or ionic bonds with liposomes augment transfection compared to liposome carriers alone. More recently, we have examined peptides as sole carriers of nucleic acids because of their intrinsic advantages compared to the bipartite HK/liposome carriers. With a protocol change and addition of a histidine-rich tail, HK peptides as sole carriers were more effective than liposomes alone in several cell lines. While four-branched polymers with a primary repeating sequence pattern of -HHK- were more effective as carriers of plasmids, eight-branched polymers with a sequence pattern of -HHHK- were more effective as carriers of siRNA. Compared to polyethylenimine, HK carriers of siRNA and plasmids had reduced toxicity. When injected intravenously, HK polymers in complex with plasmids encoding antiangiogenic proteins significantly decreased tumor growth. Furthermore, modification of HK polymers with polyethylene glycol and vascular-specific ligands increased specificity of the polyplex to the tumor by more than 40-fold. Together with further development and insight on the structure of HK polyplexes, HK peptides may prove to be useful as carriers of different forms of nucleic acids both in vitro and in vivo.

  17. Recombination in liquid filled ionisation chambers with multiple charge carrier species: Theoretical and numerical results

    International Nuclear Information System (INIS)

    Aguiar, P.; González-Castaño, D.M.; Gómez, F.; Pardo-Montero, J.

    2014-01-01

    Liquid-filled ionisation chambers (LICs) are used in radiotherapy for dosimetry and quality assurance. Volume recombination can be quite important in LICs for moderate dose rates, causing non-linearities in the dose rate response of these detectors, and needs to be corrected for. This effect is usually described with Greening and Boag models for continuous and pulsed radiation respectively. Such models assume that the charge is carried by two different species, positive and negative ions, each of those species with a given mobility. However, LICs operating in non-ultrapure mode can contain different types of electronegative impurities with different mobilities, thus increasing the number of different charge carriers. If this is the case, Greening and Boag models can be no longer valid and need to be reformulated. In this work we present a theoretical and numerical study of volume recombination in parallel-plate LICs with multiple charge carrier species, extending Boag and Greening models. Results from a recent publication that reported three different mobilities in an isooctane-filled LIC have been used to study the effect of extra carrier species on recombination. We have found that in pulsed beams the inclusion of extra mobilities does not affect volume recombination much, a behaviour that was expected because Boag formula for charge collection efficiency does not depend on the mobilities of the charge carriers if the Debye relationship between mobilities and recombination constant holds. This is not the case in continuous radiation, where the presence of extra charge carrier species significantly affects the amount of volume recombination. - Highlights: • Analytical extension of Greening and Boag theories to multiple charge carriers. • Detailed numerical study of process of volume recombination in LICs. • Recombination in pulsed beams is independent of number and mobilities of carriers. • Multiple charge carriers have a significant effect in continuous

  18. Technology-supported training of arm-hand skills in stroke

    NARCIS (Netherlands)

    Timmermans, A.A.A.

    2010-01-01

    Impaired arm-hand performance is a serious consequence of stroke that is associated with reduced self-efficacy and poor quality of life. Task-oriented arm training is a therapy approach that is known to improve skilled arm-hand performance, even in chronic stages after stroke. At the start of this

  19. Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys

    Science.gov (United States)

    Ifft, Peter J.; Shokur, Solaiman; Li, Zheng; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2014-01-01

    Brain-machine interfaces (BMIs) are artificial systems that aim to restore sensation and movement to severely paralyzed patients. However, previous BMIs enabled only single arm functionality, and control of bimanual movements was a major challenge. Here, we developed and tested a bimanual BMI that enabled rhesus monkeys to control two avatar arms simultaneously. The bimanual BMI was based on the extracellular activity of 374–497 neurons recorded from several frontal and parietal cortical areas of both cerebral hemispheres. Cortical activity was transformed into movements of the two arms with a decoding algorithm called a 5th order unscented Kalman filter (UKF). The UKF is well-suited for BMI decoding because it accounts for both characteristics of reaching movements and their representation by cortical neurons. The UKF was trained either during a manual task performed with two joysticks or by having the monkeys passively observe the movements of avatar arms. Most cortical neurons changed their modulation patterns when both arms were engaged simultaneously. Representing the two arms jointly in a single UKF decoder resulted in improved decoding performance compared with using separate decoders for each arm. As the animals’ performance in bimanual BMI control improved over time, we observed widespread plasticity in frontal and parietal cortical areas. Neuronal representation of the avatar and reach targets was enhanced with learning, whereas pairwise correlations between neurons initially increased and then decreased. These results suggest that cortical networks may assimilate the two avatar arms through BMI control. PMID:24197735

  20. An Atypical Mitochondrial Carrier That Mediates Drug Action in Trypanosoma brucei.

    Directory of Open Access Journals (Sweden)

    Juan P de Macêdo

    2015-05-01

    Full Text Available Elucidating the mechanism of action of trypanocidal compounds is an important step in the development of more efficient drugs against Trypanosoma brucei. In a screening approach using an RNAi library in T. brucei bloodstream forms, we identified a member of the mitochondrial carrier family, TbMCP14, as a prime candidate mediating the action of a group of anti-parasitic choline analogs. Depletion of TbMCP14 by inducible RNAi in both bloodstream and procyclic forms increased resistance of parasites towards the compounds by 7-fold and 3-fold, respectively, compared to uninduced cells. In addition, down-regulation of TbMCP14 protected bloodstream form mitochondria from a drug-induced decrease in mitochondrial membrane potential. Conversely, over-expression of the carrier in procyclic forms increased parasite susceptibility more than 13-fold. Metabolomic analyses of parasites over-expressing TbMCP14 showed increased levels of the proline metabolite, pyrroline-5-carboxylate, suggesting a possible involvement of TbMCP14 in energy production. The generation of TbMCP14 knock-out parasites showed that the carrier is not essential for survival of T. brucei bloodstream forms, but reduced parasite proliferation under standard culture conditions. In contrast, depletion of TbMCP14 in procyclic forms resulted in growth arrest, followed by parasite death. The time point at which parasite proliferation stopped was dependent on the major energy source, i.e. glucose versus proline, in the culture medium. Together with our findings that proline-dependent ATP production in crude mitochondria from TbMCP14-depleted trypanosomes was reduced compared to control mitochondria, the study demonstrates that TbMCP14 is involved in energy production in T. brucei. Since TbMCP14 belongs to a trypanosomatid-specific clade of mitochondrial carrier family proteins showing very poor similarity to mitochondrial carriers of mammals, it may represent an interesting target for drug

  1. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  2. Primary design of Si cooling arm structure in ICF cryogenic target

    International Nuclear Information System (INIS)

    Zhang Yong; Yi Yong; Tang Changhuan; Zhang Jicheng

    2013-01-01

    According to the requirement of the cryogenic target system to the Si cooling arm structure, the Si cooling arm was primarily designed based on the USA National Ignition Facility (NIF) target. A new three-dimensional model of Si cooling arm was developed by SolidWorks software, and the simulation and analysis of Si cooling arm in aspect of mechanical property, thermal response and assembly were made based on the model. A law about the effect of the arm length of Si cooling arm and the width and the length of bifurcation on Si cooling arm was achieved. The research may provide the theoretical foundation and reference for the further improvement of cryogenic target. (authors)

  3. SIPRI's new conceptual approach to arms control and disarmament

    International Nuclear Information System (INIS)

    Rotfeld, Adam Daniel

    2000-01-01

    The end of the cold war deprioritized arms control and disarmament, and progress in the field was no longer a measure of relations among the major powers. In that context, the future of arms control and disarmament was discussed at the Nobel Symposium in October 1999. Stockholm International Peace Research Institute (SIPRI) views arms control as an instrument for shaping a new inclusive and cooperative security order. The author questions whether arms control challenges today can and should be resolved in the institutions established and the procedures elaborated in the bipolar framework. (author)

  4. Motor carrier evaluation program

    International Nuclear Information System (INIS)

    Portsmouth, James

    1992-01-01

    The U.S. Department of Energy-Headquarters (DOE-HQ), Transportation Management Program (TMP) has the overall responsibility to provide a well-managed transportation program for the safe, efficient, and economical transportation of DOE-owned materials. The DOE-TMP has established an excellent safety record in the transportation of hazardous materials including radioactive materials and radioactive wastes. This safety record can be maintained only through continued diligence and sustained effort on the part of the DOE-TMP, its field offices, and the contractors' organizations. Key elements in the DOE'S effective hazardous and radioactive materials shipping program are (1) integrity of packages, (2) strict adherence to regulations and procedures, (3) trained personnel, (4) complete management support, and (5) use of the best commercial carriers. The DOE Motor Carrier Evaluation Program was developed to better define the criteria and methodology needed to identify motor carriers for use in the transportation of Highway Route Controlled Quantities (HRCQ), Truck Load (TL) quantities of radioactive materials, hazardous materials and waste. (author)

  5. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  6. ARM Enhanced Shortwave Experiment (ARESE) Solar Radiation Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARM Enhanced Shortwave Experiment (ARESE) was conducted at the Department of Energy's ARM Southern Great Plains (SGP) Central Facility between September 22, 1995...

  7. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    In August 2006, the U.S. Government imposed sanctions on Russian arms sellers and producers, Rosoboroneksport, Russia's main arms-selling agency, and Sukhoi, which manufactures aircraft, because of their arms sales to Iran...

  8. Slow hot carrier cooling in cesium lead iodide perovskites

    Science.gov (United States)

    Shen, Qing; Ripolles, Teresa S.; Even, Jacky; Ogomi, Yuhei; Nishinaka, Koji; Izuishi, Takuya; Nakazawa, Naoki; Zhang, Yaohong; Ding, Chao; Liu, Feng; Toyoda, Taro; Yoshino, Kenji; Minemoto, Takashi; Katayama, Kenji; Hayase, Shuzi

    2017-10-01

    Lead halide perovskites are attracting a great deal of interest for optoelectronic applications such as solar cells, LEDs, and lasers because of their unique properties. In solar cells, heat dissipation by hot carriers results in a major energy loss channel responsible for the Shockley-Queisser efficiency limit. Hot carrier solar cells offer the possibility to overcome this limit and achieve energy conversion efficiency as high as 66% by extracting hot carriers. Therefore, fundamental studies on hot carrier relaxation dynamics in lead halide perovskites are important. Here, we elucidated the hot carrier cooling dynamics in all-inorganic cesium lead iodide (CsPbI3) perovskite using transient absorption spectroscopy. We observe that the hot carrier cooling rate in CsPbI3 decreases as the fluence of the pump light increases and the cooling is as slow as a few 10 ps when the photoexcited carrier density is 7 × 1018 cm-3, which is attributed to phonon bottleneck for high photoexcited carrier densities. Our findings suggest that CsPbI3 has a potential for hot carrier solar cell applications.

  9. A unique collaboration of female medical providers within the United States Armed Forces: rehabilitation of a marine with post-concussive vestibulopathy.

    Science.gov (United States)

    Gottshall, Kim; Gray, Nicola; Drake, Angela I

    2005-01-01

    Uncle Sam's loyal nieces have come a long way from the days of World War I. The development of occupational and physical therapy was heavily influenced by an early relationship with medical specialists during the First World War. This relationship can be considered largely responsible for the eventual acceptance (by the Armed Forces) of women working in this area. Over the past decade active duty women have seen many changes in opportunities to serve and are now stationed aboard aircraft carriers, performing roles previously considered for male personnel. We report a case study of the medical care provided by both military and civilian women working for the United States Armed Forces. Initial assessment was conducted in a battalion aid station of a United States Marine Corp base and the subject was then referred to a military medical center with highly technical vestibular assessment and rehabilitation services. The subject's case represents a unique collaboration of women therapists, enabling a Marines' access to timely and accurate assessment, treatment and ultimately, successful return to active duty. This case study is one of many examples of the acceptance and successful integration of women as providers of medical care within the Military's medical framework.

  10. Accuracy and precision of flash glucose monitoring sensors inserted into the abdomen and upper thigh compared with the upper arm.

    Science.gov (United States)

    Charleer, Sara; Mathieu, Chantal; Nobels, Frank; Gillard, Pieter

    2018-06-01

    Nowadays, most Belgian patients with type 1 diabetes use flash glucose monitoring (FreeStyle Libre [FSL]; Abbott Diabetes Care, Alameda, California) to check their glucose values, but some patients find the sensor on the upper arm too visible. The aim of the present study was to compare the accuracy and precision of FSL sensors when placed on different sites. A total of 23 adults with type 1 diabetes used three FSL sensors simultaneously for 14 days on the upper arm, abdomen and upper thigh. FSL measurements were compared with capillary blood glucose (BG) measurements obtained with a built-in FSL BG meter. The aggregated mean absolute relative difference was 11.8 ± 12.0%, 18.5 ± 18.4% and 12.3 ± 13.8% for the arm, abdomen (P = .002 vs arm) and thigh (P = .5 vs arm), respectively. Results of Clarke error grid analysis for the arm and thigh were similar (zone A: 84.9% vs 84.5%; P = .6), while less accuracy was seen for the abdomen (zone A: 69.4%; P = .01). Apart from the first day, the accuracy of FSL sensors on the arm and thigh was more stable across the 14-day wear duration than accuracy of sensors on the abdomen, which deteriorated mainly during week 2 (P < .0005). The aggregated precision absolute relative difference was markedly lower for the arm/thigh (10.9 ± 11.9%) compared with the arm/abdomen (20.9 ± 22.8%; P = .002). Our results indicate that the accuracy and precision of FSL sensors placed on the upper thigh are similar to the upper arm, whereas the abdomen performed unacceptably poorly. © 2018 John Wiley & Sons Ltd.

  11. Homosexuality in the Dutch Armed Forces 2006

    NARCIS (Netherlands)

    Anna Adolfsen; Saskia Keuzenkamp; m.m.v. Linda Mans

    2006-01-01

    Original title: Uniform uit de kast. This study looks at the attitudes of defence personnel to homosexuality. How do members of the military view homosexual colleagues? Can gays and lesbians working in the armed forces be open about their sexual preferences? Do they regard the armed forces as

  12. TOWARDS UNIFORM RULES FOR ARMED CONFLICTS Pieter ...

    African Journals Online (AJOL)

    the two Additional Protocols that followed in 1977, divide armed conflict into two legal categories: ... Wounded, Sick and Shipwrecked Members of Armed Forces at Sea. Third Convention ... Nationalist China; ibid 116. ... 17 Pictet op cit 43; Junod, S 'Additional Protocol II: History and Scope' (1983) 33 The. American ...

  13. Limited consensus around ARM information protection practices1

    African Journals Online (AJOL)

    KATUU, Shadrack

    surrounding Information Protection (IP) has been ... compares IP and ARM information protection through .... decision-making methodology used to help ... and differing requirements of institutions into account. ARM literature is prescriptive with.

  14. 78 FR 66801 - Motor Carrier Safety Advisory Committee; Charter Renewal

    Science.gov (United States)

    2013-11-06

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee; Charter Renewal AGENCY: Federal Motor Carrier Safety... and recommendations on motor carrier safety programs and motor carrier safety regulations through a...

  15. Cancer risk in MLH1, MSH2 and MSH6 mutation carriers; different risk profiles may influence clinical management

    Directory of Open Access Journals (Sweden)

    Ramsoekh Dewkoemar

    2009-12-01

    Full Text Available Abstract Background Lynch syndrome (LS is associated with a high risk for colorectal cancer (CRC and extracolonic malignancies, such as endometrial carcinoma (EC. The risk is dependent of the affected mismatch repair gene. The aim of the present study was to calculate the cumulative risk of LS related cancers in proven MLH1, MSH2 and MSH6 mutation carriers. Methods The studypopulation consisted out of 67 proven LS families. Clinical information including mutation status and tumour diagnosis was collected. Cumulative risks were calculated and compared using Kaplan Meier survival analysis. Results MSH6 mutation carriers, both males and females had the lowest risk for developing CRC at age 70 years, 54% and 30% respectively and the age of onset was delayed by 3-5 years in males. With respect to endometrial carcinoma, female MSH6 mutation carriers had the highest risk at age 70 years (61% compared to MLH1 (25% and MSH2 (49%. Also, the age of EC onset was delayed by 5-10 years in comparison with MLH1 and MSH2. Conclusions Although the cumulative lifetime risk of LS related cancer is similar, MLH1, MSH2 and MSH6 mutations seem to cause distinguishable cancer risk profiles. Female MSH6 mutation carriers have a lower CRC risk and a higher risk for developing endometrial carcinoma. As a consequence, surveillance colonoscopy starting at age 30 years instead of 20-25 years is more suitable. Also, prophylactic hysterectomy may be more indicated in female MSH6 mutation carriers compared to MLH1 and MSH2 mutation carriers.

  16. Nudging Armed Groups: How Civilians Transmit Norms of Protection

    Directory of Open Access Journals (Sweden)

    Oliver Kaplan

    2013-12-01

    Full Text Available What are the varying roles that norms play to either enable or constrain violence in armed conflict settings? The article examines this question by drawing on experiences from communities and armed groups in Colombia and Syria. It begins by presenting an explanation of how norms of violence and nonviolence may arise within communities and influence the behavior of civilian residents, reducing the chances of them becoming involved with armed groups. It then considers how civilian communities can transmit those same norms, shared understandings, and patterns of interaction to the ranks of illegal armed groups and subsequently shape their decisions about the use of violence against civilians. The author argues that civilians may be better positioned to promote the principles codified in International Humanitarian Law than international humanitarian organizations because they have closer contact with irregular armed actors and are viewed with greater legitimacy. The analysis illustrates that to better understand civilian protection mechanisms it is essential to study the interactions between communities and armed actors.

  17. Carrier scattering in metals and semiconductors

    CERN Document Server

    Gantmakher, VF

    1987-01-01

    The transport properties of solids, as well as the many optical phenomena in them are determined by the scattering of current carriers. ``Carrier Scattering in Metals and Semiconductors'' elucidates the state of the art in the research on the scattering mechanisms for current carriers in metals and semiconductors and describes experiments in which these mechanisms are most dramatically manifested.The selection and organization of the material is in a form to prepare the reader to reason independently and to deal just as independently with available theoretical results and experimental

  18. Performance of Uplink Carrier Aggregation in LTE-Advanced Systems

    DEFF Research Database (Denmark)

    Wang, Hua; Rosa, Claudio; Pedersen, Klaus

    2010-01-01

    Carrier aggregation (CA) has been proposed to aggregate two or more component carriers (CCs) to support a much wider transmission bandwidth for LTE-Advanced systems. With carrier aggregation, it is possible to schedule a user equipment (UE) on multiple component carriers simultaneously. In this p...

  19. Carrier tracking by smoothing filter improves symbol SNR

    Science.gov (United States)

    Pomalaza-Raez, Carlos A.; Hurd, William J.

    1986-01-01

    The potential benefit of using a smoothing filter to estimate carrier phase over use of phase locked loops (PLL) is determined. Numerical results are presented for the performance of three possible configurations of the deep space network advanced receiver. These are residual carrier PLL, sideband aided residual carrier PLL, and finally sideband aiding with a Kalman smoother. The average symbol signal to noise ratio (SNR) after losses due to carrier phase estimation error is computed for different total power SNRs, symbol rates and symbol SNRs. It is found that smoothing is most beneficial for low symbol SNRs and low symbol rates. Smoothing gains up to 0.4 dB over a sideband aided residual carrier PLL, and the combined benefit of smoothing and sideband aiding relative to a residual carrier loop is often in excess of 1 dB.

  20. Cryo-scanning electron microscopy investigation of the Octopus Vulgaris arm structures for the design of an octopus-like arm artefact.

    Science.gov (United States)

    Minnocci, Antonio; Cianchetti, Matteo; Mazzolai, Barbara; Sebastiani, Luca; Laschi, Cecilia

    2015-12-01

    Octopus vulgaris is a cephalopod of the Octopodidae family. It has four pairs of arms and two rows of suckers which perform many functions, including bending and elongation. For this reason the octopus was chosen as model to develop a new generation of soft-body robots. In order to explain some of the fine structures of the octopus arm in relation to its specific ability, we examined the external and internal structures of O. vulgaris arms in a frozen-hydrated state using cryo-scanning electron microscopy. The arms showed skin with a very complex design that is useful to elongation, and a pore pattern distribution on their surface which is functional to cutaneous oxygen uptake. The analysis of freeze-fractured frozen-hydrated arm samples allowed us to describe the developmental differences in the relative proportion of the areas of axial nerve cord, intrinsic and extrinsic musculature, in relation to the growth of the arms and of the increase in functional capability. In the suckers, we analyzed the shedding mechanisms in the outer part of the infundibulum and described the outer and inner characteristics of the denticles, showing in detail their pore system, which is fundamental for their ability to explore the environment. These results are discussed by considering their possible application in the design of new octopus-like artefacts, which will be able to take advantage of some of these ultrastructure characteristics and achieve advanced bioinspired functionalities. © 2015 Wiley Periodicals, Inc.

  1. Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chin-Chen; Lee, Bo-Ching; Chang, Yeun-Chung; Liu, Kao-Lang [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Medical Imaging, Taipei (China); Wu, Vin-Cent [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Internal Medicine, Taipei (China); Huang, Kuo-How [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Urology, Taipei (China); Collaboration: on behalf of the TAIPAI Study Group

    2017-12-15

    To compare the performance of on-site quick cortisol assay (QCA) and C-arm computed tomography (CT) assistance on adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. The institutional review board at our hospital approved this retrospective study, which included 178 consecutive patients with primary aldosteronism. During AVS, we used C-arm CT to confirm right adrenal cannulation between May 2012 and June 2015 (n = 100) and QCA for bilateral adrenal cannulation between July 2015 and September 2016 (n = 78). Successful AVS required a selectivity index (cortisol{sub adrenal} {sub vein}/cortisol{sub peripheral}) of ≥ 2.0 bilaterally. The overall success rate of C-arm CT-assisted AVS was 87%, which increased to 97.4% under QCA (P =.013). The procedure time (C-arm CT, 49.5 ± 21.3 min; QCA, 37.5 ± 15.6 min; P <.001) and radiation dose (C-arm CT, 673.9 ± 613.8 mGy; QCA, 346.4 ± 387.8 mGy; P <.001) were also improved. The resampling rate was 16% and 21.8% for C-arm CT and QCA, respectively. The initial success rate of the performing radiologist remained stable during the study period (C-arm CT 75%; QCA, 82.1%, P =.259). QCA might be superior to C-arm CT for improving the performance of AVS. (orig.)

  2. Quantitative spectrographic analysis of Li, Na and Ca in uranium base materials, using the carrier distillation technique

    International Nuclear Information System (INIS)

    Gomes, R.P.; Brito, J. de.

    1978-01-01

    A spectrographic method for the quantitative determination of Ca, Li and Na in uranium base materials is described. The carrier destillation technique is used and a study is made for the selection of best carrier compounds. In U 3 O 8 matrix, the best results are obtained with 4% In 2 O 3 for the determination of Na and a 15% mixed carrier (3 NaCl + 1 Y 2 O 3 ) for the determination of Ca and Li. The minium determination limit for Ca and Li is 1 ppm while for Na it is 15 ppm. The precision of the method is calculated and the relative standard deviation is found to be 11, 16 and 6,5% for Ca, Li and Na respectively [pt

  3. First description of Cryptosporidium parvum in carrier pigeons (Columba livia).

    Science.gov (United States)

    Oliveira, Bruno César Miranda; Ferrari, Elis Domingos; da Cruz Panegossi, Mariele Fernanda; Nakamura, Alex Akira; Corbucci, Flávio Sader; Nagata, Walter Bertequini; Dos Santos, Bianca Martins; Gomes, Jancarlo Ferreira; Meireles, Marcelo Vasconcelos; Widmer, Giovanni; Bresciani, Katia Denise Saraiva

    2017-08-30

    The carrier pigeon and the domestic pigeon are different breeds of the species Columba livia. Carrier pigeons are used for recreational activities such as bird contests and exhibitions. Due to the close contact with humans, these birds may potentially represent a public health risk, since they can host and disseminate zoonotic parasites, such as those belonging to the genus Cryptosporidium (phylum Apicomplexa). The purpose of this work was the detection by microscopic and molecular techniques of Cryptosporidium spp. oocysts in fecal samples of carrier pigeons, and subsequently to sequence the 18S ribosomal RNA marker of positive samples to identify the species. A total of 100 fecal samples were collected individually in two pigeon breeding facilities from Formiga and Araçatuba, cities located in Minas Gerais state and São Paulo state, Brazil, respectively. The age of the birds ranged from one to 12 years; 56 were females and 44 males. Fecal smears were stained with negative malachite green, whereas the molecular characterization was based on the sequence of a ∼800bp fragment of the 18S rRNA gene. Microscopic examination of fecal smears revealed 4% (4/100) oocyst positivity. On the other hand, 7% (7/100) of positivity were found using nested PCR. Three samples were 99% to 100% similar to Cryptosporidium parvum 18S rDNA type A (Genbank AH006572) and the other three samples had 99% to 100% similarity to C. parvum 18S rDNA type B (Genbank AF308600). To our knowledge, this is the first report of C. parvum oocysts in carrier pigeons. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Driver citation/carrier data relationship project

    Science.gov (United States)

    1996-09-01

    The Driver/Carrier Relationship Project was commissioned to address three issues. The first was to determine if drivers of commercial motor vehicles get tickets at a different rate, depending on the carrier that they are working for. The second issue...

  5. Majority- and minority-carrier deep level traps in proton-irradiated n+/p-InGaP space solar cells

    International Nuclear Information System (INIS)

    Dharmarasu, Nethaji; Yamaguchi, Masafumi; Bourgoin, Jacques C.; Takamoto, Tatsuya; Ohshima, Takeshi; Itoh, Hisayoshi; Imaizumi, Mitsuru; Matsuda, Sumio

    2002-01-01

    We report the properties of observed defects in n + /p-InGaP solar cells created by irradiation of protons of different energies. Three majority (hole) and a minority-carrier traps, labeled respectively as HP1 (E v +0.90±0.05 eV), HP2 (E v +0.73±0.05 eV), H2 (E v +0.55 eV), and EP1 (E c -0.54 eV), were identified using deep level transient spectroscopy. All majority-carrier traps were found to act as recombination centers. While the H2 trap present in the proton-irradiated p-InGaP was found to anneal out by minority-carrier injection, the other traps were not

  6. Homozygous carriers of the TCF7L2 rs7903146 T-allele show altered postprandial response in triglycerides and triglyceride-rich lipoproteins

    DEFF Research Database (Denmark)

    Engelbrechtsen, L; Hansen, T H; Mahendran, Y

    2017-01-01

    to CC carriers. Additionally, TT carriers had lower postprandial levels of total triglycerides (TG) (q = 0.03), VLDL-TG (q = 0.05, including medium, small and extra small, q = 0.048, q = 0.0009, q = 0.04, respectively), HDL-TG (triglycerides in high density lipoproteins q = 0.037) and S-HDL-TG (q = 0.......00003). In conclusion, TT carriers show altered postprandial triglyceride response, mainly influencing VLDL and HDL subclasses suggesting a genotype-mediated effect on hepatic lipid regulation....

  7. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, Kengo; Lin, Chia Hui [Department of Earth and Space Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Machida, Masahiro N. [Department of Earth and Planetary Sciences, Faculty of Sciences, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Hosokawa, Takashi [Department of Physics, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan); Sakurai, Yuya, E-mail: tomida@vega.ess.sci.osaka-u.ac.jp [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan)

    2017-01-20

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  8. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    International Nuclear Information System (INIS)

    Tomida, Kengo; Lin, Chia Hui; Machida, Masahiro N.; Hosokawa, Takashi; Sakurai, Yuya

    2017-01-01

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  9. Cortical volumes and atrophy rates in FTD-3 CHMP2B mutation carriers and related non-carriers

    DEFF Research Database (Denmark)

    Eskildsen, Simon F; Østergaard, Lasse R; Rodell, Anders B

    2008-01-01

    with a mean interval of 16 months and surface based cortical segmentation we measured cortical thickness and volume, and quantified atrophy rates. Cortical thickness and atrophy rates were averaged within major lobes and focal effects were determined by parametric statistical maps. The volumetric atrophy...... in the frontal and occipital lobes, and in the left temporal lobe. Results indicated that cortical thickness has a higher sensitivity for detecting small changes than whole-brain volumetric measures. Comparing mutation carriers with non-carriers revealed increased atrophy rates in mutation carriers bilaterally...

  10. Literature review of the passenger airline business models : Full service carrier, low-cost carrier and charter airlines

    NARCIS (Netherlands)

    Carmona Benitez, R.B.; Lodewijks, G.

    2008-01-01

    The deregulation and liberalization of the air transportation industry have developed three main passenger business models: full service carriers, low-cost carriers, and charter airlines. Deregulation removed regulated fares and routes increasing competition and yields. Airlines business models main

  11. Capsaicin-loaded nanolipoidal carriers for topical application: design, characterization, and in vitro/in vivo evaluation

    Directory of Open Access Journals (Sweden)

    Wang XR

    2017-05-01

    Full Text Available Xia-Rong Wang,1 Si-Qian Gao,1 Xiao-Qian Niu,1 Long-Jian Li,2 Xiao-Ying Ying,1 Zhong-Jie Hu,2 Jian-Qing Gao1,3 1Institute of Pharmaceutics, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 2Zhejiang Provincial Corps Hospital of Chinese People’s Armed Police Forces, Jiaxing, Zhejiang, 3Jiangsu Engineering Research Center for New-Type External and Transdermal Preparations, Jiangsu, People’s Republic of China Abstract: Capsaicin has been used in clinical applications for the treatment of pain disorders and inflammatory diseases. Given the strong pungency and high oil/water partition coefficient of capsaicin, capsaicin-loaded nanolipoidal carriers (NLCs were designed to increase permeation and achieve the analgesic, anti-inflammatory effect with lower skin irritation. Capsaicin-loaded NLCs were prepared and later optimized by the Box–Behnken design. The physicochemical characterizations, morphology, and encapsulation of the capsaicin-loaded NLCs were subsequently confirmed. Capsaicin-loaded NLCs and capsaicin-loaded NLCs gel exhibited sustained release and no cytotoxicity properties. Also, they could significantly enhance the penetration amount, permeation flux, and skin retention amounts of capsaicin due to the application of NLCs. To study the topical permeation mechanism of capsaicin, 3,3'-dioctadecyloxacarbocyanine perchlorate (Dio was used as a fluorescent dye. Dio-loaded NLCs and Dio-loaded NLCs gel could effectively deliver Dio up to a skin depth of 260 and 210 µm, respectively, primarily through the appendage route on the basis of version skin sections compared with Dio solution, which only delivered Dio up to 150 µm. In vivo therapeutic experiments demonstrated that capsaicin-loaded NLCs and capsaicin-loaded NLCs gel could improve the pain threshold in a dose-dependent manner and inhibit inflammation, primarily by reducing the prostaglandin E2 levels in the tissue compared with capsaicin cream and capsaicin solution

  12. The globalization of the arms industry: The next proliferation challenge

    Energy Technology Data Exchange (ETDEWEB)

    Bitzinger, R.A.

    1994-12-31

    The globalization of the arms industry entails a significant shift away from traditional, single-country patterns of weapons production toward internationalization of the development, production, and marketing of arms. While wholly indigenous armaments production may be on the decline, multinational arms production - through collaboration on individual weapon systems and increasingly via interfirm linkages across the international arms industry - appears actually to be expanding. In several instances, in fact, multinational armaments production is increasingly supplementing or even supplanting indigenous or autonomous weapons production or arms imports. The emergence of an increasingly transnational defense technology and industrial base is fundamentally affecting the shape and content of much of the global arms trade. This changing defense market, in turn, will have a profound impact on a number of national security issues concerning the Western industrialized nations. 3 figs., 2 tabs.

  13. Development of the OPESCOPE mobile C-arm system

    International Nuclear Information System (INIS)

    Tsuji, Hisao; Kadowaki, Toshio; Shimizu, Yasumitsu

    1994-01-01

    A new mobile C-arm X-ray fluoroscopy system called the 'OPESCOPE' equipped with a CCD TV camera and high-definition Image Intensifier has been developed. All the cables for the I.I. and X-ray generator are held inside the C-arm to prevent interference with operation and the C-arm is locked electromagnetically. Moreover, the C-arm is spring counterbalanced in the vertical motion axis. These features enable smooth positioning and uncluttered operation. The X-ray generator uses a high-frequency inverter designed to assure noiseless operation and a compact size. With the new DFS-700 videoprocessor unit being combined, clearer, more informative images can be obtained. In addition to its inherent portability this unit can be upgraded in DSA function to allow angiographic examinations in the surgical theater. (author)

  14. The sensitivity of bit error rate (BER) performance in multi-carrier (OFDM) and single-carrier

    Science.gov (United States)

    Albdran, Saleh; Alshammari, Ahmed; Matin, Mohammad

    2012-10-01

    Recently, the single-carrier and multi-carrier transmissions have grabbed the attention of industrial systems. Theoretically, OFDM as a Multicarrier has more advantages over the Single-Carrier especially for high data rate. In this paper we will show which one of the two techniques outperforms the other. We will study and compare the performance of BER for both techniques for a given channel. As a function of signal to noise ratio SNR, the BER will be measure and studied. Also, Peak-to-Average Power Ratio (PAPR) is going to be examined and presented as a drawback of using OFDM. To make a reasonable comparison between the both techniques, we will use additive white Gaussian noise (AWGN) as a communication channel.

  15. Trigonometric parallaxes of star forming regions in the Scutum spiral arm

    International Nuclear Information System (INIS)

    Sato, M.; Wu, Y. W.; Immer, K.; Zhang, B.; Sanna, A.; Brunthaler, A.; Menten, K. M.; Reid, M. J.; Dame, T. M.

    2014-01-01

    We report measurements of trigonometric parallaxes for six high-mass star-forming regions in the Scutum spiral arm of the Milky Way as part of the BeSSeL Survey. Combining our measurements with 10 previous measurements from the BeSSeL Survey yields a total sample of 16 sources in the Scutum arm with trigonometric parallaxes in the Galactic longitude range from 5° to 32°. Assuming a logarithmic spiral model, we estimate a pitch angle of 19.°8 ± 3.°1 for the Scutum arm, which is larger than pitch angles reported for other spiral arms. The high pitch angle of the arm may be due to the arm's proximity to the Galactic bar. The Scutum arm sources show an average peculiar motion of 4 km s –1 slower than the Galactic rotation and 8 km s –1 toward the Galactic center. While the direction of this non-circular motion has the same sign as determined for sources in other spiral arms, the motion toward the Galactic center is greater for the Scutum arm sources.

  16. [Clinical application of three-dimensional O-arm navigation system in treating patients with dystrophic scoliosis secondary to neurofibromatosis type Ⅰ].

    Science.gov (United States)

    Liu, Z; Qiu, Y; Li, Y; Zhao, Z H; Wang, B; Zhu, F; Yu, Y; Sun, X; Zhu, Z Z

    2017-03-01

    Objective: To investigate the clinical outcomes and the accuracy of O-arm-navigation system assisted pedicle screw insertion in dystrophic scoliosis secondary to neurofibromatosis type Ⅰ(NF-1). Methods: A retrospective study was conducted in 41 patients with dystrophic NF-1-associated thoracic scoliosis who were surgically treated at Department of Orthopaedics, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School between June 2012 and October 2014 with more than 18 months follow-up. The patients were then divided into two groups: 18 patients were under the assistance of O-arm-navigation-based pedicle screw insertion (O-arm group) and the remaining 23 patients' pedicle screws insertion were conducted by free-hand (free-hand group). The X-ray and CT were analyzed to investigate the correction rate and safety of pedicle insertion. t -test was used to analyze measurement data and χ(2) test was used to analyze accuracy of screw insertion between the two groups. Results: The mean coronal Cobb angle was 63.2°±8.7° in the O-arm group and 66.9°±7.4° in the free-hand group ( P >0.05), which was then corrected into 23.1°±6.8° and 30.2°±7.6°( t =2.231, P =0.031) after surgery respectively.Operation time was (265.0±70.3)minutes and estimated blood loss was (1 024±465)ml in the O-arm group. Operation time and estimated blood loss was (243.0±49.6)minutes and (1 228±521)ml respectively in the free-hand group, which had no significant difference between the two groups. However, the implant density was higher in the O-arm group than that in the free-hand group ((64.1±10.8)% vs .(44.3±15.3)%)( t =4.652, P =0.000). The O-arm group comprised 122 screws, of which 72.9% were excellent, 22.1% were good and 4.9% were bad. The free-hand group comprised 136 screws and 48.5% of them were excellent, 33.8% were good and 17.6% were bad.Accuracy of pedicle screw insertion was higher in the O-arm group than that in the free-hand group(χ(2

  17. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [Herzberg Astrophysics, National Research Council Canada, National Science Infrastructure portfolio, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada)

    2014-11-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.

  18. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory

  19. Neck and arm pain syndromes

    DEFF Research Database (Denmark)

    de las Peñas, César Fernández; Cleland, Joshua; Huijbregts, Peter

    approaches.It uniquely addresses the expanding role of the various health care professions which require increased knowledge and skills in screening for contra-indications and recognizing the need for medical-surgical referral. Neck and Arm Pain Syndromes also stresses the integration of experiential......The first of its kind, Neck and Arm Pain Syndromes is a comprehensive evidence- and clinical-based book, covering research-based diagnosis, prognosis and management of neuromusculoskeletal pathologies and dysfunctions of the upper quadrant, including joint, muscle, myofascial and neural tissue...... of the most commonly seen pain syndromes in clinical practice over 800 illustrations demonstrating examination procedures and techniques....

  20. Structure of the S6 spirel arm in the Andromeda galaxy

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1982-01-01

    The distribution of stars across the spiral arm S6 in M 31 within Baade's Field 4 is investigated. It is found that the brightest stars are concentrated to the middle line of the arm where the maximal star density is also observed. The symmetry of the arm S6 may be explained by its position near the corotation radius that followed from the spiral pattern velocity Ωsub(P) approximately 10 km/s kpc determined by the age gradient in the arm S4. The similarity between the structure of the arm S6 and that of the spiral arms near the Sun is pointed out [ru

  1. Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge

    International Nuclear Information System (INIS)

    Li Jinchao; Song Zhiquan; Xu Liuwei; Fu Peng; Guo Bin; Li Sen; Dong Lin; Wang Min

    2014-01-01

    A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affecting current sharing, arm structure is the main one. During the design of the arm prototype, a novel method based on inductance matrixes is employed to improve the current sharing of the bridge arm. The test results on the prototype show that the current sharing performance of the arm prototype is much better than relevant design requirement, and that the matrix method is very effective to analyze and solve the current sharing problems of thyristor converters

  2. Carrier Lifetime in Exfoliated Few-Layer Graphene Determined from Intersubband Optical Transitions

    Science.gov (United States)

    Limmer, Thomas; Feldmann, Jochen; Da Como, Enrico

    2013-05-01

    We report a femtosecond transient spectroscopy study in the near to middle infrared range, 0.8-0.35 eV photon energy, on graphene and few layer graphene single flakes. The spectra show an evolving structure of photoinduced absorption bands superimposed on the bleaching caused by Pauli blocking of the interband optically coupled states. Supported by tight-binding model calculations, we assign the photoinduced absorption features to intersubband transitions as the number of layers is increased. Interestingly, the intersubband photoinduced resonances show a longer dynamics than the interband bleaching, because of their independence from the absolute energy of the carriers with respect to the Dirac point. The dynamic of these intersubband transitions reflects the lifetime of the hot carriers and provides an elegant method to access it in this important class of semimetals.

  3. Carrier lifetime in exfoliated few-layer graphene determined from intersubband optical transitions.

    Science.gov (United States)

    Limmer, Thomas; Feldmann, Jochen; Da Como, Enrico

    2013-05-24

    We report a femtosecond transient spectroscopy study in the near to middle infrared range, 0.8-0.35 eV photon energy, on graphene and few layer graphene single flakes. The spectra show an evolving structure of photoinduced absorption bands superimposed on the bleaching caused by Pauli blocking of the interband optically coupled states. Supported by tight-binding model calculations, we assign the photoinduced absorption features to intersubband transitions as the number of layers is increased. Interestingly, the intersubband photoinduced resonances show a longer dynamics than the interband bleaching, because of their independence from the absolute energy of the carriers with respect to the Dirac point. The dynamic of these intersubband transitions reflects the lifetime of the hot carriers and provides an elegant method to access it in this important class of semimetals.

  4. Terahertz carrier dynamics in graphene and graphene nanostructures

    DEFF Research Database (Denmark)

    Jensen, Søren A.; Turchinovich, Dmitry; Tielrooij, Klaas Jan

    2014-01-01

    Photoexcited charge carriers in 2D graphene and in 1D graphene nanostructures were studied with optical pump-THz probe spectroscopy. We find efficient hot-carrier multiplication in 2D graphene, and predominantly free carrier early time response in 1D nanostructures. © 2014 OSA....

  5. Lasting effects of workplace strength training for neck/shoulder/arm pain among laboratory technicians

    DEFF Research Database (Denmark)

    Mortensen, Peter; Larsen, Anders I; Zebis, Mette Kreutzfeldt

    2014-01-01

    Objectives. This study investigated long-term effects and implementation processes of workplace strength training for musculoskeletal disorders. Methods. 333 and 140 laboratory technicians from private and public sector companies, respectively, replied to a 3-year follow-up questionnaire subseque...... be implemented successfully at different companies during working hours on a long-term basis with lasting effects on pain in neck, shoulder, and arm....

  6. Evaluation of local free carrier concentrations in individual heavily-doped GaN:Si micro-rods by micro-Raman spectroscopy

    Science.gov (United States)

    Mohajerani, M. S.; Khachadorian, S.; Schimpke, T.; Nenstiel, C.; Hartmann, J.; Ledig, J.; Avramescu, A.; Strassburg, M.; Hoffmann, A.; Waag, A.

    2016-02-01

    Three-dimensional III-nitride micro-structures are being developed as a promising candidate for the future opto-electrical devices. In this study, we demonstrate a quick and straight-forward method to locally evaluate free-carrier concentrations and a crystalline quality in individual GaN:Si micro-rods. By employing micro-Raman mapping and analyzing lower frequency branch of A1(LO)- and E1(LO)-phonon-plasmon-coupled modes (LPP-), the free carrier concentrations are determined in axial and planar configurations, respectively. Due to a gradual doping profile along the micro-rods, a highly spatially resolved mapping on the sidewall is exploited to reconstruct free carrier concentration profile along the GaN:Si micro-rods. Despite remarkably high free carrier concentrations above 1 × 1020 cm-3, the micro-rods reveal an excellent crystalline quality, without a doping-induced stress.

  7. Aerial Logistics Management for Carrier Onboard Delivery

    Science.gov (United States)

    2016-09-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS AERIAL LOGISTICS MANAGEMENT FOR CARRIER ONBOARD DELIVERY by Samuel L. Chen September 2016...AND SUBTITLE AERIAL LOGISTICS MANAGEMENT FOR CARRIER ONBOARD DELIVERY 5. FUNDING NUMBERS 6. AUTHOR(S) Samuel L. Chen 7. PERFORMING ORGANIZATION NAME(S...delivery (COD) is the use of aircraft to transport people and cargo from a forward logistics site (FLS) to a carrier strike group (CSG). The goal of

  8. Carrier-phonon interaction in semiconductor quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Seebeck, Jan

    2009-03-10

    In recent years semiconductor quantum dots have been studied extensively due to their wide range of possible applications, predominantly for light sources. For successful applications, efficient carrier scattering processes as well as a detailed understanding of the optical properties are of central importance. The aims of this thesis are theoretical investigations of carrier scattering processes in InGaAs/GaAs quantum dots on a quantum-kinetic basis. A consistent treatment of quasi-particle renormalizations and carrier kinetics for non-equilibrium conditions is presented, using the framework of non-equilibrium Green's functions. The focus of our investigations is the interaction of carriers with LO phonons. Important for the understanding of the scattering mechanism are the corresponding quasi-particle properties. Starting from a detailed study of quantum-dot polarons, scattering and dephasing processes are discussed for different temperature regimes. The inclusion of polaron and memory effects turns out to be essential for the description of the carrier kinetics in quantum-dot systems. They give rise to efficient scattering channels and the obtained results are in agreement with recent experiments. Furthermore, a consistent treatment of the carrier-LO-phonon and the carrier-carrier interaction is presented for the optical response of semiconductor quantum dots, both giving rise to equally important contributions to the dephasing. Beside the conventional GaAs material system, currently GaN based light sources are of high topical interest due to their wide range of possible emission frequencies. In this material additionally intrinsic properties like piezoelectric fields and strong band-mixing effects have to be considered. For the description of the optical properties of InN/GaN quantum dots a procedure is presented, where the material properties obtained from an atomistic tight-binding approach are combined with a many-body theory for non

  9. CHARACTERIZING SPIRAL ARM AND INTERARM STAR FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Kreckel, K.; Schinnerer, E.; Meidt, S. [Max Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanc, G. A. [Departamento de Astronomía, Universidad de Chile, Camino del Observatorio 1515, Las Condes, Santiago (Chile); Groves, B. [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Adamo, A. [Department of Astronomy, The Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Hughes, A., E-mail: kreckel@mpia.de [CNRS, IRAP, 9 Av. du Colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France)

    2016-08-20

    Interarm star formation contributes significantly to a galaxy’s star formation budget and provides an opportunity to study stellar birthplaces unperturbed by spiral arm dynamics. Using optical integral field spectroscopy of the nearby galaxy NGC 628 with VLT/MUSE, we construct H α maps including detailed corrections for dust extinction and stellar absorption to identify 391 H ii regions at 35 pc resolution over 12 kpc{sup 2}. Using tracers sensitive to the underlying gravitational potential, we associate H ii regions with either arm (271) or interarm (120) environments. Using our full spectral coverage of each region, we find that most physical properties (luminosity, size, metallicity, ionization parameter) of H ii regions are independent of environment. We calculate the fraction of H α luminosity due to the background of diffuse ionized gas (DIG) contaminating each H ii region, and find the DIG surface brightness to be higher within H ii regions than in the surroundings, and slightly higher within arm H ii regions. Use of the temperature-sensitive [S ii]/H α line ratio instead of the H α surface brightness to identify the boundaries of H ii regions does not change this result. Using the dust attenuation as a tracer of the gas, we find depletion times consistent with previous work (2 × 10{sup 9} yr) with no differences between the arm and interarm, but this is very sensitive to the DIG correction. Unlike molecular clouds, which can be dynamically affected by the galactic environment, we see fairly consistent properties of H ii regions in both arm and interarm environments. This suggests either a difference in star formation and feedback in arms or a decoupling of dense star-forming clumps from the more extended surrounding molecular gas.

  10. Effect of arm swing strategy on local dynamic stability of human gait.

    Science.gov (United States)

    Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H

    2015-02-01

    Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. 2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

    Science.gov (United States)

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J; Sorger, Jonathan M; Armand, Mehran; Taylor, Russell H

    2015-08-01

    C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D-3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Intensity-based 2D-3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ:∼ 30°. The two C-arm systems provided TRE mean ≤ 2.5 mm and TRE mean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). C-arm 3D localization from dual 2D-3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system.

  12. The European Union and armed drones: framing the debate

    DEFF Research Database (Denmark)

    Martins, Bruno Oliveira

    2015-01-01

    Armed drones are an issue extremely relevant for the EU. The recent emergence of targeted killings as a common counter-terrorism technique, the existence of several EU member states using armed and surveillance drones in military scenarios, the presence of member states troops in areas where armed...... drones have been active, the US use of European-originated intelligence to execute targeted killings, and the broader status of international law, are developments that illustrate the importance of the topic. Yet, the EU still does not have an official position on armed drones. In 2014 the European...... Parliament recognized that this is problematic, adopting a Resolution that expressed “grave concern over the use of armed drones outside the international legal framework” and that urged the EU to “develop an appropriate policy response at both European and global level”. This Forum answers to the European...

  13. Investigation of cosmogenic radionuclide carriers in the atmosphere

    International Nuclear Information System (INIS)

    Lujaniene, G.

    2000-01-01

    Speciation of 7 Be, 32 P, 33 P, 35 S and stable S carriers and their changes in the atmosphere were investigated. It has been determined that aerosol-carriers of 7 Be, 32 P and 33 P radionuclides can have different properties, and after several days their transformation was observed. The amount of water-soluble carriers in aerosol samples differed widely (from 11 to 95 %). The dependence of radionuclide carrier solubility on pH was obtained for 7 Be, 32 P and 33 P. It has been found that 7 Be carriers can be soluble compounds such as mixed chlorides, sulphates and nitrates as well as insoluble carbonates and insoluble hydrous Fe(III) oxides. High percentage of 32 P and 33 P was found in exchangeable fraction. The 35 S carriers were found to be more soluble than those of 7 Be, 32 P and 33 P and exhibited a lower or the same solubility as stable sulphur. (author)

  14. Fractures of the humerus during arm wrestling

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko Ž.

    2014-01-01

    Full Text Available Background/Aim. Humeral shaft fractures may occur as a result of arm wrestling. The aim of this study was to present our treatment of humerus fracture sustained during arm wrestling. Methods. A total of six patients, aged 22 to 48, were treated at our department form January 2008 to January 2010 with open reduction and internal fixation and with hanging arm casts. A review of all the relevant literature on the subject was also presented. Results. In all the cases, the fractures healed and function returned to normal. No patient had any neural or vascular compromise. Conclusion. Closed and operative treatments were equally successful in all reported cases. [Projekat Ministarstva nauke Republike Srbije, br. 175-095

  15. ARM Climate Research Facility Annual Report 2005

    Energy Technology Data Exchange (ETDEWEB)

    J. Voyles

    2005-12-31

    Through the ARM Program, the DOE funded the development of several highly instrumented ground stations for studying cloud formation processes and their influence on radiative transfer, and for measuring other parameters that determine the radiative properties of the atmosphere. This scientific infrastructure, and resultant data archive, is a valuable national and international asset for advancing scientific knowledge of Earth systems. In fiscal year (FY) 2003, the DOE designated ARM sites as a national scientific user facility: the ARM Climate Research (ACRF). The ACRF has enormous potential to contribute to a wide range interdisciplinary science in areas such as meteorology, atmospheric aerosols, hydrology, biogeochemical cycling, and satellite validation, to name only a few.

  16. Preparation and characterization of oligochitosan-tragacanth nanoparticles as a novel gene carrier.

    Science.gov (United States)

    Fattahi, Ali; Sadrjavadi, Komail; Golozar, Mohammad Ali; Varshosaz, Jaleh; Fathi, Mohammad-Hossein; Mirmohammad-Sadeghi, Hamid

    2013-09-12

    The nanoparticles of oligochitosan-water soluble tragacanth (OCH-WST) as novel gene carriers have been prepared and their transfection efficiency has been investigated on Hela and HepG2 cell lines. Different OCH:WST weight ratios were prepared to obtain particles with low size distribution and high surface charge, and also in range of below 200 nm. Nanoparticles with 132.5 ± 6.77 nm size, polydispersity index 1.92 ± 0.061, surface charge 30.45 ± 1.84 and spherical morphology, have been chosen as gene carrier. Nanoparticle-DNA complexes (nanoplexes) showed better transfection efficiency in both Hela and HepG2 cells than chitosan polyplexes, with 1.26 × 10(6) versus 9.05 × 10(5) and 7.76 × 10(5) versus 2.16 × 10(5), respectively. Higher transfection efficiency of nanoplexes could be attributed to their weaker complexation. Decreasing of transfection in presence of galactose in HepG2 cells, indicated receptor mediated endocytosis of nanoplexes. These properties all together, make OCH-WST nanoparticles as potential gene carrier for active gene delivery into cells containing sugar receptors. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Arms Trafficking and Colombia

    National Research Council Canada - National Science Library

    Cragin, Kim; Hoffman, Bruce

    2003-01-01

    ... to traditional definitions of a security threat. For this analysis, the term "small arms" refers to man-portable personal and military weapons, ranging from handguns to assault rifles to surface-to-air missiles (SAMs...

  18. Quantitative assessment of paretic limb dexterity and interlimb coordination during bilateral arm rehabilitation training.

    Science.gov (United States)

    Xu, Chang; Li, Siyi; Wang, Kui; Hou, Zengguang; Yu, Ningbo

    2017-07-01

    In neuro-rehabilitation after stroke, the conventional constrained induced movement therapy (CIMT) has been well-accepted. Existing bilateral trainings are mostly on mirrored symmetrical motion. However, complementary bilateral movements are dominantly involved in activities of daily living (ADLs), and functional bilateral therapies may bring better skill transfer from trainings to daily life. Neurophysiological evidence is also growing. In this work, we firstly introduce our bilateral arm training system realized with a haptic interface and a motion sensor, as well as the tasks that have been designed to train both the manipulation function of the paretic arm and coordination of bilateral upper limbs. Then, we propose quantitative measures for functional assessment of complementary bilateral training performance, including kinematic behavior indices, smoothness, submovement and bimanual coordination. After that, we describe the experiments with healthy subjects and the results with respect to these quantitative measures. Feasibility and sensitivity of the proposed indices were evaluated through comparison of unilateral and bilateral training outcomes. The proposed bilateral training system and tasks, as well as the quantitative measures, have been demonstrated effective for training and assessment of unilateral and bilateral arm functions.

  19. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  20. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  1. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Laboratory; Sisterson, DL [Argonne National Laboratory

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily-accessible, well-articulated estimate of ARM measurement uncertainty is needed.

  2. Inert carrier drying and coating process

    International Nuclear Information System (INIS)

    1980-01-01

    An inert carrier process is described for drying radioactive (particularly low level) waste material and for incorporating the dry material into a binder matrix from which the dried material will not be leached. Experimental details, and examples of the carrier and binder materials, are given. (U.K.)

  3. Participation in Armed Forces, National, and International Sports Activities

    Science.gov (United States)

    1987-03-09

    American Games , Olympic Games , and other authorized national and international sports competitions (to include qualifying and preparatory events) as long...concerning the participation of Armed Forces personnel in Armed Forces, national, and international sports competitions ; establishes a Senior Military Sports ...program is to ensure that the U.S. Armed Forces are appropriately represented in national and international sports competitions . 3. The purpose of this

  4. RAPID DETECTION OF -THALASSEMIA MUTATIONS IN THAILAND USING MULTIPLEX ARMS

    Directory of Open Access Journals (Sweden)

    D. Shimbhu

    2017-11-01

    Full Text Available The number of mutations underlining b-thalassemia generate a wide variety of different clinical phenotypes. An understanding of the genotype is important for medical personnel in order to provide proper counseling to patients and their families. Characterization of these mutations should aid the planning of a prenatal diagnosis program for bthalassemia. The heterogeneity of the mutations makes it difficult and time consuming to identify the mutation in some individuals. We developed a single-tube multiplex amplification refractory mutation system (multiplex ARMS to identify common ethnic- specific b-thalassemia mutations. Confirmation of multiplex ARMS results was carried out using direct sequencing. Three thousand three hundred twenty two people from Phitsanulok province were screened for the b-thalassemia trait by quantitation of HbA2 with microcolumn chromatography and the genotypes of mutations were characterized using multiplex ARMS and direct sequencing. We found that the deletion at codons 41/42 (-TCTT was the most frequent (48%, codon 17 (A®T (30%, -28 (A®G (6% and IVS-I-1(G®T (6% were the second and third in frequency respectively. A -87 (C®A mutation (4%, IVS II-654 (C®T (2%, codons 71/72 (+A (2% and codon 35 (C®A mutations (2% were also found. These techniques were found to be a valuable tool for analysis of b-thalassemia mutations because they are accurate, simple, and speedy in operation. The application for the diagnosis of severe thalassemia in high-risk pregnancies is promising.

  5. Inter-arm blood pressure difference in hospitalized elderly patients--is it consistent?

    Science.gov (United States)

    Grossman, Alon; Weiss, Avraham; Beloosesky, Yichayaou; Morag-Koren, Nira; Green, Hefziba; Grossman, Ehud

    2014-07-01

    Inter-arm blood pressure difference (IAD) is recognized as a risk factor for cardiovascular mortality. Its reproducibility in the elderly is unknown. The authors determined the prevalence and reproducibility of IAD in hospitalized elderly patients. Blood pressure was measured simultaneously in both arms on two different days in elderly individuals hospitalized in a geriatric ward. The study included 364 elderly patients (mean age, 85±5 years). Eighty-four patients (23%) had systolic IAD >10 and 62 patients (17%) had diastolic IAD >10 mm Hg. A total of 319 patients had two blood pressure measurements. Systolic and diastolic IAD remained in the same category in 203 (64%) and 231 (72%) patients, respectively. Correlations of systolic and diastolic IAD between the two measurements were poor. Consistency was not affected by age, body mass index, comorbidities, or treatment. IAD is extremely common in hospitalized elderly patients, but, because of poor consistency, its clinical significance in this population is uncertain. ©2014 Wiley Periodicals, Inc.

  6. Spiral arms, comets and terrestrial catastrophism

    International Nuclear Information System (INIS)

    Clube, S.V.M.; Napier, W.M.

    1982-01-01

    A review is presented of an hypothesis of terrestrial catastrophism in which comets grow in molecular clouds and are captured by the Sun as it passes through the spiral arms of the Galaxy. Assuming that comets are a major supplier of the Earth-crossing (Appollo) asteroid population, the latter fluctuates correspondingly and leads to episodes of terrestrial bombardment. Changes in the rotational momentum of core and mantle, generated by impacts, lead to episodes of magnetic field reversal and tectonic activity, while surface phenomena lead to ice-ages and mass extinctions. An episodic geophysical history with an interstellar connection is thus implied. If comets in spiral arms are necessary intermediaries in the process of star formation, the theory also has implications relating to early solar system history and galactic chemistry. These aspects are briefly discussed with special reference to the nature of spiral arms. (author)

  7. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  8. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  9. Nonequilibrium carrier dynamics in transition metal dichalcogenide semiconductors

    Science.gov (United States)

    Steinhoff, A.; Florian, M.; Rösner, M.; Lorke, M.; Wehling, T. O.; Gies, C.; Jahnke, F.

    2016-09-01

    When exploring new materials for their potential in (opto)electronic device applications, it is important to understand the role of various carrier interaction and scattering processes. In atomically thin transition metal dichalcogenide semiconductors, the Coulomb interaction is known to be much stronger than in quantum wells of conventional semiconductors like GaAs, as witnessed by the 50 times larger exciton binding energy. The question arises, whether this directly translates into equivalently faster carrier-carrier Coulomb scattering of excited carriers. Here we show that a combination of ab initio band-structure and many-body theory predicts Coulomb-mediated carrier relaxation on a sub-100 fs time scale for a wide range of excitation densities, which is less than an order of magnitude faster than in quantum wells.

  10. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  11. Nutrient capture and recycling by periphyton attached to modified agrowaste carriers.

    Science.gov (United States)

    Wan, Juanjuan; Liu, Xuemei; Wu, Chenxi; Wu, Yonghong

    2016-04-01

    The reuse of periphytic biofilm from traditional wastewater treatment (i.e., active sludge process) is inefficient to recycle nutrients due to low accumulation of nutrients. Then, in this study, peanut shell (PS), rice husk (RH), decomposed peanut shell (DPS), acidified rice husks (ARH), and a commonly used carrier-ceramsite (C, as the control)-were used to support the growth of periphyton. Results showed that DPS and ARH supported significantly higher periphyton biomass and metabolic versatility than PS and RH, respectively, due to the increased presence of positive groups. The total nitrogen (TN) and total phosphorus (TP) captured by periphyton were enhanced by 600-657 and 833-3255 % for DPS, and 461-1808 and 21-308 % for ARH, respectively. The removal of nutrients from simulated eutrophic surface waters using periphyton attached to DPS was improved by 24-47 % for TP, 12-048 % for TN, and 15-78 % for nitrate compared to the control. The results indicate that the periphyton attached to modified agrowaste was capable of efficiently entrapping and storing N and P from eutrophic water. This study also implies that the mixture of periphyton and the modified agrowaste carriers are promising raw materials of biofertilizer.

  12. The Influences of Arm Resist Motion on a CAR Crash Test Using Hybrid III Dummy with Human-Like Arm

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Bae, Hanil; Choi, Hyeonki

    Safety of the occupant during the crash is very essential design element. Many researches have been investigated in reducing the fatal injury of occupant. They are focusing on the development of a dummy in order to obtain the real human-like motion. However, they have not considered the arm resist motion during the car accident. In this study, we would like to suggest the importance of the reactive force of the arm in a car crash. The influences of reactive force acting on the human upper extremity were investigated using the impedance experimental method with lumped mass model of hand system and a Hybrid III dummy with human-like arm. Impedance parameters (e.g. inertia, spring constant and damping coefficient) of the elbow joint in maximum activation level were measured by free oscillation test using single axis robot. The results showed that without seat belt, the reactive force of human arm reduced the head, chest, and femur injury, and the flexion moment of the neck is higher than that of the conventional dummy.

  13. AN OUTER ARM IN THE SECOND GALACTIC QUADRANT: STRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xinyu; Xu, Ye; Yang, Ji; Sun, Yan; Li, Facheng; Zhang, Shaobo; Zhou, Xin, E-mail: xydu@pmo.ac.cn, E-mail: xuye@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Science, Nanjing 210008 (China)

    2016-05-01

    The lack of arm tracers, especially remote tracers, is one of the most difficult problems preventing us from studying the structure of the Milky Way. Fortunately, with its high-sensitivity CO survey, the Milky Way Imaging Scroll Painting (MWISP) project offers such an opportunity. Since completing about one-third of its mission, an area of l = [100, 150]°, b = [−3, 5]° has nearly been covered. The Outer arm of the Milky Way first clearly revealed its shape in the second galactic quadrant in the form of molecular gas—this is the first time that the Outer arm has been reported in such a large-scale mapping of molecular gas. Using the 115 GHz {sup 12}CO(1–0) data of MWISP at the LSR velocity ≃[−100, −60] km s{sup −1} and in the area mentioned above, we have detected 481 molecular clouds in total, and among them 332 (about 69%) are newly detected and 457 probably belong to the Outer arm. The total mass of the detected Outer arm clouds is ∼3.1 × 10{sup 6} M {sub ⊙}. Assuming that the spiral arm is a logarithmic spiral, the pitch angle is fitted as ∼13.°1. Besides combining both the CO data from MWISP and the 21 cm H i data from the Canadian Galactic Plane Survey (CGPS), the gas distribution, warp, and thickness of the Outer arm are also studied.

  14. Deep Arm/Ear-ECG Image Learning for Highly Wearable Biometric Human Identification.

    Science.gov (United States)

    Zhang, Qingxue; Zhou, Dian

    2018-01-01

    In this study, to advance smart health applications which have increasing security/privacy requirements, we propose a novel highly wearable ECG-based user identification system, empowered by both non-standard convenient ECG lead configurations and deep learning techniques. Specifically, to achieve a super wearability, we suggest situating all the ECG electrodes on the left upper-arm, or behind the ears, and successfully obtain weak but distinguishable ECG waveforms. Afterwards, to identify individuals from weak ECG, we further present a two-stage framework, including ECG imaging and deep feature learning/identification. In the former stage, the ECG heartbeats are projected to a 2D state space, to reveal heartbeats' trajectory behaviors and produce 2D images by a split-then-hit method. In the second stage, a convolutional neural network is introduced to automatically learn the intricate patterns directly from the ECG image representations without heavy feature engineering, and then perform user identification. Experimental results on two acquired datasets using our wearable prototype, show a promising identification rate of 98.4% (single-arm-ECG) and 91.1% (ear-ECG), respectively. To the best of our knowledge, it is the first study on the feasibility of using single-arm-ECG/ear-ECG for user identification purpose, which is expected to contribute to pervasive ECG-based user identification in smart health applications.

  15. Armed guards on vessels : insurance and liability

    Directory of Open Access Journals (Sweden)

    Mišo Mudrić

    2011-12-01

    Full Text Available The Paper examines the insurance and liability issues resulting from the use of armed guards on board vessels. The study begins with an overview of the available data on key economic fi gures representing the projected overall annual costs of modern piracy. The focus is then shifted to the issue of public versus private security, where possible dangers of private-based security options are discussed in general. After explaining why the Somalia region deserves a closer attention when compared to other pirate-infested waters, a brief summary of the international effort to combat piracy threat is presented, followed by a structured overview of the use of private maritime security options in the maritime sector in general. One security option is the use of armed guards on board vessels. This option is explored both from the political (the acceptance by stakeholders and legal standpoint (legal issues arising from the use of armed guards. An important remedy for the shipping companies/ operators threatened by the piracy hazard is the existence of affordable and effective (specialized marine insurance. A study of available piracy insurance policies is presented, followed by an analysis of case law and other legal issues arising from piracy attacks, which could prove important when considering the legal implications of armed guards employment. Finally, a simplifi ed economic analysis of available security options is presented, followed by the final assessment of benefi ts derived from the use of armed guards.

  16. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  17. High capacity carrier ethernet transport networks

    DEFF Research Database (Denmark)

    Rasmussen, Anders; Zhang, Jiang; Yu, Hao

    2009-01-01

    OAM functions, survivability and the increased bandwidth requirements of carrier class systems. This article provides an overview of PBB-TE and T-MPLS and demonstrates how IPTV services can be realized in the framework of Carrier Ethernet. In addition we provide a case study on performing bit error...

  18. Validation of the Omron MIT Elite blood pressure device in a pregnant population with large arm circumference.

    Science.gov (United States)

    James, Lauren; Nzelu, Diane; Hay, Anna; Shennan, Andrew; Kametas, Nikos A

    2017-04-01

    The aim of this study was to evaluate the accuracy of the Omron MIT Elite automated device in pregnant women with an arm circumference of or above 32 cm, using the British Hypertension Society validation protocol. Blood pressure was measured sequentially in 46 women of any gestation requiring the use of a large cuff (arm circumference ≥32 cm) alternating between the mercury sphygmomanometer and the Omron MIT Elite device. The Omron MIT Elite achieved an overall D/D grade with a mean of the device-observer difference being 7.17±6.67 and 9.31±6.59 for systolic and diastolic blood pressure respectively. Interobserver accuracy was 94.6% for systolic and 95% for diastolic readings within 5 mmHg. The Omron MIT Elite overestimates blood pressure and has failed the British Hypertension Society protocol requirements. Therefore, it cannot be recommended for use in pregnant women with an arm circumference of or above 32 cm.

  19. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  20. A Scintigraphic Method for Quantitation of Lymphatic Function in Arm Lymphedema

    DEFF Research Database (Denmark)

    Hvidsten, Svend; Toyserkani, Navid M; Sørensen, Jens A

    2018-01-01

    ) measure of lymph fluid passing through the arm. METHODS AND RESULTS: Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent simultaneous bilateral lymphoscintigraphy using intradermal injection of 99mTc-labeled human serum albumin (HSA). Imaging...... was performed at 30-45 minute intervals for 5 hours. Time activity curves from each injection site and each arm region were recorded. The input into the arm region was obtained as the (minus) time derivative of the injection site activity curve. In the proposed model the arm activity curve was considered...

  1. Stability of low-carrier-density topological-insulator Bi2Se3 thin films and effect of capping layers

    International Nuclear Information System (INIS)

    Salehi, Maryam; Brahlek, Matthew; Koirala, Nikesh; Moon, Jisoo; Oh, Seongshik; Wu, Liang; Armitage, N. P.

    2015-01-01

    Although over the past number of years there have been many advances in the materials aspects of topological insulators (TIs), one of the ongoing challenges with these materials is the protection of them against aging. In particular, the recent development of low-carrier-density bulk-insulating Bi 2 Se 3 thin films and their sensitivity to air demands reliable capping layers to stabilize their electronic properties. Here, we study the stability of the low-carrier-density Bi 2 Se 3 thin films in air with and without various capping layers using DC and THz probes. Without any capping layers, the carrier density increases by ∼150% over a week and by ∼280% over 9 months. In situ-deposited Se and ex situ-deposited poly(methyl methacrylate) suppress the aging effect to ∼27% and ∼88%, respectively, over 9 months. The combination of effective capping layers and low-carrier-density TI films will open up new opportunities in topological insulators

  2. Dynamic parameter identification of robot arms with servo-controlled electrical motors

    Science.gov (United States)

    Jiang, Zhao-Hui; Senda, Hiroshi

    2005-12-01

    This paper addresses the issue of dynamic parameter identification of the robot manipulator with servo-controlled electrical motors. An assumption is made that all kinematical parameters, such as link lengths, are known, and only dynamic parameters containing mass, moment of inertia, and their functions need to be identified. First, we derive dynamics of the robot arm with a linear form of the unknown dynamic parameters by taking dynamic characteristics of the motor and servo unit into consideration. Then, we implement the parameter identification approach to identify the unknown parameters with respect to individual link separately. A pseudo-inverse matrix is used for formulation of the parameter identification. The optimal solution is guaranteed in a sense of least-squares of the mean errors. A Direct Drive (DD) SCARA type industrial robot arm AdeptOne is used as an application example of the parameter identification. Simulations and experiments for both open loop and close loop controls are carried out. Comparison of the results confirms the correctness and usefulness of the parameter identification and the derived dynamic model.

  3. Analysis of hypothetical loss-of-control-arm accidents in HIFAR

    International Nuclear Information System (INIS)

    Connolly, J.W.; Clark, N.

    1986-11-01

    The reactor power transient produced in the HIFAR materials testing reactor upon severance of a central coarse control arm connecting rod and the subsequent pivoting of the arm out of the core has been calculated for a range of reactor conditions likely to be encountered in normal operation. It is concluded that as long as the remaining arms of the control arm bank can be relied on to suppress the post power peak oscillations in power, the reactor will withstand the consequences of such an accident

  4. Charge-carrier dynamics and Coulomb effects in semiconductor tetrapods

    International Nuclear Information System (INIS)

    Mauser, Christian

    2011-01-01

    In this thesis the Coulomb interaction and its influence on localization effects and dynamics of charge carriers in semiconductor nanocrystals were studied. In the studied nanostructures it deals with colloidal tetrapod heterostructures, which consist of a cadmium selenide (CdSe) core and four tetraedrical grown cadmium sulfide (CdS) respectively cadmium telluride (CdTe) legs, which exhibit a type-I respectively type-II band transition. The dynamics and interactions were studied by means of photoluminescence (PL) and absorption measurements both on the ensemble and on single nanoparticles, as well as time-resolved PL and transient absorption spectroscopy. Additionally theoretical simulations of the wave-function distributions were performed, which are based on the effective-mass approximation. The special band structure of the CdSe/CdS tetrapods offers a unique possibility to study the Coulomb interaction. The flat conduction band in these heterostructures makes the electron via the Coulomb interaction sensitive to the localization position of the hole within the structure. The valence band has instead a potential maximum in the CdSe, which leads to a directed localization of the hole and the photoluminescence of the core. Polarization-resolved measurements showed hereby an anisotropy of the photoluminescence, which could be explained by means of simulations of the wave-function distribution with an asymmetry at the branching point. Charge-carrier localization occur mainly both in longer structures and in trap states in the CdS leg and can be demonstrated in form of a dual emission from a nanocrystal. The charge-carrier dynamics of electron and hole in tetrapods is indeed coupled by the Coulomb interaction, however it cannot be completely described in an exciton picture. The coupled dynamics and the Coulomb interaction were studied concerning a possible influence of the geometry in CdSe/CdS nanorods and compared with those of the tetrapods. The interactions of the

  5. Overview of Actuated Arm Support Systems and Their Applications

    Directory of Open Access Journals (Sweden)

    E.A. Lomonova

    2013-10-01

    Full Text Available Arm support systems provide support throughout daily tasks, training or in an industrial environment. During the last decades a large diversity of actuated arm support systems have been developed. To analyze the actuation principles in these systems, an overview of actuated arm support systems is provided. This overview visualizes the current trends on research and development of these support systems and distinguishes three categories. These categories depend mainly on the functional status of the user environment, which defines the specifications. Therefore, the actuated arm support systems are classified according to their user environment, namely: ambulatory, rehabilitation and industrial. Furthermore, three main actuation principles and three mechanical construction principles have been identified.

  6. Mid-upper-arm-circumference and mid-upper-arm circumference z-score

    DEFF Research Database (Denmark)

    Rasmussen, J; Andersen, A; Fisker, A B

    2012-01-01

    Mid-upper-arm circumference (MUAC) is a simple method of assessing nutritional status in children above 6 months of age. In 2007 World Health Organization (WHO) introduced a MUAC z-score for children above 3 months of age. We evaluated whether MUAC or MUAC z-score had the best ability to identify...

  7. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  8. 49 CFR 398.3 - Qualifications of drivers or operators.

    Science.gov (United States)

    2010-10-01

    ... possesses the following minimum qualifications: (1) No loss of foot, leg, hand or arm, (2) No mental..., impairment of use of foot, leg, fingers, hand or arm, or other structural defect or limitation, likely to... CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS...

  9. 76 FR 32390 - Motor Carrier Safety Advisory Committee Public Meeting

    Science.gov (United States)

    2011-06-06

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of Motor Carrier Safety Advisory Committee (MCSAC) Meeting. SUMMARY...

  10. 77 FR 46555 - Motor Carrier Safety Advisory Committee: Public Meeting

    Science.gov (United States)

    2012-08-03

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee: Public Meeting AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of meeting of Motor Carrier Safety Advisory Committee (MCSAC...

  11. 75 FR 2923 - Motor Carrier Safety Advisory Committee Public Meeting

    Science.gov (United States)

    2010-01-19

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of Motor Carrier Safety Advisory Committee Meeting. SUMMARY: FMCSA...

  12. 75 FR 29384 - Motor Carrier Safety Advisory Committee Public Meeting

    Science.gov (United States)

    2010-05-25

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2010-0143] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of Motor Carrier Safety Advisory Committee meeting. SUMMARY: FMCSA...

  13. 75 FR 72863 - Motor Carrier Safety Advisory Committee Public Meeting

    Science.gov (United States)

    2010-11-26

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety Administration, DOT. ACTION: Notice of Motor Carrier Safety Advisory Committee Meeting. SUMMARY: FMCSA announces...

  14. 75 FR 50797 - Motor Carrier Safety Advisory Committee Public Meeting

    Science.gov (United States)

    2010-08-17

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2010-0143] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of Motor Carrier Safety Advisory Committee Meeting. SUMMARY: FMCSA...

  15. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  16. Enhanced piezoelectric output of NiO/nanoporous GaN by suppression of internal carrier screening

    Science.gov (United States)

    Waseem, Aadil; Jeong, Dae Kyung; Johar, Muhammad Ali; Kang, Jin-Ho; Ha, Jun-Seok; Key Lee, June; Ryu, Sang-Wan

    2018-06-01

    The efficiency of piezoelectric nanogenerators (PNGs) significantly depends on the free carrier concentration of semiconductors. In the presence of a mechanical stress, piezoelectric charges are generated at both ends of the PNG, which are rapidly screened by the free carriers. The screening effect rapidly decreases the piezoelectric output within fractions of a second. In this study, the piezoelectric outputs of bulk- and nanoporous GaN-based heterojunction PNGs are compared. GaN thin films were epitaxially grown on sapphire substrates using metal organic chemical vapor deposition. Nanoporous GaN was fabricated using electrochemical etching, depleted of free carriers owing to the surface Fermi-level pinning. A highly resistive NiO thin film was deposited on bulk- and nanoporous GaN using radio frequency magnetron sputter. The NiO/nanoporous GaN PNG (NPNG) under a periodic compressive stress of 4 MPa exhibited an output voltage and current of 0.32 V and 1.48 μA cm‑2, respectively. The output voltage and current of the NiO/thin film-GaN PNG (TPNG) were three and five times smaller than those of the NPNG, respectively. Therefore, the high-resistivity of NiO and nanoporous GaN depleted by the Fermi-level pinning are advantageous and provide a better piezoelectric performance of the NPNG, compared with that of the TPNG.

  17. Smooth-arm spiral galaxies: their properties and significance to cluster-galaxy evolution

    International Nuclear Information System (INIS)

    Wilkerson, M.S.

    1979-01-01

    In this dissertation a number of galaxies with optical appearances between those of normal, actively-star-forming spirals and SO galaxies have been examined. These so-called smooth-arm spiral galaxies exhibit spiral arms without any of the spiral tracers - H II regions, O-B star associations, dust - indicative of current star formation. Tests were made to find if, perhaps, these smooth-arm spirals could have, at one time, been normal, actively-star-forming spirals whose gas had been somehow removed; and that are currently transforming into SO galaxies. This scenario proceeds as (1) removal of gas, (2) gradual dying of disk density wave, (3) emergence of SO galaxy. If the dominant method of gas removal is ram-pressure stripping by a hot, intracluster medium, then smooth-arm spirals should occur primarily in x-ray clusters. Some major findings of this dissertation are as follows: (1) Smooth-arm spirals are redder than normal spirals of the same morphological type. Most smooth-arm spirals cannot be distinguished by color from SO galaxies. (2) A weak trend exists for smooth-arm spirals with stronger arms to be bluer than those with weaker arms; thus implying that the interval since gas removal has been shorter for the galaxies with stronger arms. (3) Smooth-arm spirals are deficient in neutral hydrogen - sometimes by an order of magnitude or, possibly, more

  18. Dynamic model of the octopus arm. II. Control of reaching movements.

    Science.gov (United States)

    Yekutieli, Yoram; Sagiv-Zohar, Roni; Hochner, Binyamin; Flash, Tamar

    2005-08-01

    The dynamic model of the octopus arm described in the first paper of this 2-part series was used here to investigate the neural strategies used for controlling the reaching movements of the octopus arm. These are stereotypical extension movements used to reach toward an object. In the dynamic model, sending a simple propagating neural activation signal to contract all muscles along the arm produced an arm extension with kinematic properties similar to those of natural movements. Control of only 2 parameters fully specified the extension movement: the amplitude of the activation signal (leading to the generation of muscle force) and the activation traveling time (the time the activation wave takes to travel along the arm). We found that the same kinematics could be achieved by applying activation signals with different activation amplitudes all exceeding some minimal level. This suggests that the octopus arm could use minimal amplitudes of activation to generate the minimal muscle forces required for the production of the desired kinematics. Larger-amplitude signals would generate larger forces that increase the arm's stability against perturbations without changing the kinematic characteristics. The robustness of this phenomenon was demonstrated by examining activation signals with either a constant or a bell-shaped velocity profile. Our modeling suggests that the octopus arm biomechanics may allow independent control of kinematics and resistance to perturbation during arm extension movements.

  19. Characterisation of spray dried soy sauce powders made by adding crystalline carbohydrates to drying carrier.

    Science.gov (United States)

    Wang, Wei; Zhou, Weibiao

    2015-02-01

    This study aimed to reduce stickiness and caking of spray dried soy sauce powders by introducing a new crystalline structure into powder particles. To perform this task, soy sauce powders were formulated by using mixtures of cellulose and maltodextrin or mixtures of waxy starch and maltodextrin as drying carriers, with a fixed carrier addition rate of 30% (w/v) in the feed solution. The microstructure, crystallinity, solubility as well as stickiness and caking strength of all the different powders were analysed and compared. Incorporating crystalline carbohydrates in the drying carrier could significantly reduce the stickiness and caking strength of the powders when the ratio of crystalline carbohydrates to maltodextrin was above 1:5 and 1:2, respectively. X-ray Diffraction (XRD) results showed that adding cellulose or waxy starch could induce the crystallinity of powders. Differential Scanning Calorimetry (DSC) results demonstrated that the native starch added to the soy sauce powders did not fully gelatinize during spray drying. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Biomacromolecules as carriers in drug delivery and tissue engineering.

    Science.gov (United States)

    Zhang, Yujie; Sun, Tao; Jiang, Chen

    2018-01-01

    Natural biomacromolecules have attracted increased attention as carriers in biomedicine in recent years because of their inherent biochemical and biophysical properties including renewability, nontoxicity, biocompatibility, biodegradability, long blood circulation time and targeting ability. Recent advances in our understanding of the biological functions of natural-origin biomacromolecules and the progress in the study of biological drug carriers indicate that such carriers may have advantages over synthetic material-based carriers in terms of half-life, stability, safety and ease of manufacture. In this review, we give a brief introduction to the biochemical properties of the widely used biomacromolecule-based carriers such as albumin, lipoproteins and polysaccharides. Then examples from the clinic and in recent laboratory development are summarized. Finally the current challenges and future prospects of present biological carriers are discussed.

  1. A prognostic scoring system for arm exercise stress testing.

    Science.gov (United States)

    Xie, Yan; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Wan, Leping; Martin, Wade H

    2016-01-01

    Arm exercise stress testing may be an equivalent or better predictor of mortality outcome than pharmacological stress imaging for the ≥50% for patients unable to perform leg exercise. Thus, our objective was to develop an arm exercise ECG stress test scoring system, analogous to the Duke Treadmill Score, for predicting outcome in these individuals. In this retrospective observational cohort study, arm exercise ECG stress tests were performed in 443 consecutive veterans aged 64.1 (11.1) years. (mean (SD)) between 1997 and 2002. From multivariate Cox models, arm exercise scores were developed for prediction of 5-year and 12-year all-cause and cardiovascular mortality and 5-year cardiovascular mortality or myocardial infarction (MI). Arm exercise capacity in resting metabolic equivalents (METs), 1 min heart rate recovery (HRR) and ST segment depression ≥1 mm were the stress test variables independently associated with all-cause and cardiovascular mortality by step-wise Cox analysis (all pstatistic of 0.81 before and 0.88 after adjustment for significant demographic and clinical covariates. Arm exercise scores for the other outcome end points yielded C-statistic values of 0.77-0.79 before and 0.82-0.86 after adjustment for significant covariates versus 0.64-0.72 for best fit pharmacological myocardial perfusion imaging models in a cohort of 1730 veterans who were evaluated over the same time period. Arm exercise scores, analogous to the Duke Treadmill Score, have good power for prediction of mortality or MI in patients who cannot perform leg exercise.

  2. Hot carrier dynamics in plasmonic transition metal nitrides

    Science.gov (United States)

    Habib, Adela; Florio, Fred; Sundararaman, Ravishankar

    2018-06-01

    Extraction of non-equilibrium hot carriers generated by plasmon decay in metallic nano-structures is an increasingly exciting prospect for utilizing plasmonic losses, but the search for optimum plasmonic materials with long-lived carriers is ongoing. Transition metal nitrides are an exciting class of new plasmonic materials with superior thermal and mechanical properties compared to conventional noble metals, but their suitability for plasmonic hot carrier applications remains unknown. Here, we present fully first principles calculations of the plasmonic response, hot carrier generation and subsequent thermalization of all group IV, V and VI transition metal nitrides, fully accounting for direct and phonon-assisted transitions as well as electron–electron and electron–phonon scattering. We find the largest frequency ranges for plasmonic response in ZrN, HfN and WN, between those of gold and silver, while we predict strongest absorption in the visible spectrum for the VN, NbN and TaN. Hot carrier generation is dominated by direct transitions for most of the relevant energy range in all these nitrides, while phonon-assisted processes dominate only below 1 eV plasmon energies primarily for the group IV nitrides. Finally, we predict the maximum hot carrier lifetimes to be around 10 fs for group IV and VI nitrides, a factor of 3–4 smaller than noble metals, due to strong electron–phonon scattering. However, we find longer carrier lifetimes for group V nitrides, comparable to silver for NbN and TaN, while exceeding 100 fs (twice that of silver) for VN, making them promising candidates for efficient hot carrier extraction.

  3. The purposes, achievements, and priorities of arms control

    International Nuclear Information System (INIS)

    Brown, P.S.

    1987-09-01

    Arms control purposes include strengthening the framework of deterrence and reducing the threat of the use of nuclear weapons, reducing the dangers of attack and accidental nuclear war, and allowing more resources for the civilian economy. The paper briefly describes achievements in arms control since World War II. These include the Limited Test Ban Treaty (LTBT), Nonproliferation Treaty (NPT), Anti-Ballistic Missile Treaty (ABMT)-SALT I, SALT II, Threshold Test Ban Treaty (TTBT), Peaceful Nuclear Explosions Treaty (PNET), and Nuclear-Free Zones treaties. The author also discusses his views on what the priorities of arms control activities should be

  4. Synthesis of core-fluorescent four-armed star and dicyclic 8-shaped poly(THF)s by electrostatic self-assembly and covalent fixation (ESA–CF) protocol

    KAUST Repository

    Fujiwara, Susumu; Yamamoto, Takuya; Tezuka, Yasuyuki; Habuchi, Satoshi

    2013-01-01

    A pair of four-armed star and dicyclic 8-shaped poly(tetrahydrofuran)s, poly(THF)s, possessing a perylene diimide group at the core position (Ia and Ib, respectively) were synthesized by means of an electrostatic self-assembly and covalent fixation (ESA–CF) protocol. Mono- and bifunctional poly(THF)s having N-phenylpiperidinium salt end groups accompanying a perylene diimide tetracarboxylate as a counteranion were prepared by the ion-exchange reaction, and the subsequent covalent conversion by reflux in toluene afforded the corresponding core-fluorescent four-armed star and dicyclic 8-shaped poly(THF)s, (Ia and Ib, respectively) for the use of single-molecule fluorescence microscopy measurements.

  5. Synthesis of core-fluorescent four-armed star and dicyclic 8-shaped poly(THF)s by electrostatic self-assembly and covalent fixation (ESA–CF) protocol

    KAUST Repository

    Fujiwara, Susumu

    2013-12-07

    A pair of four-armed star and dicyclic 8-shaped poly(tetrahydrofuran)s, poly(THF)s, possessing a perylene diimide group at the core position (Ia and Ib, respectively) were synthesized by means of an electrostatic self-assembly and covalent fixation (ESA–CF) protocol. Mono- and bifunctional poly(THF)s having N-phenylpiperidinium salt end groups accompanying a perylene diimide tetracarboxylate as a counteranion were prepared by the ion-exchange reaction, and the subsequent covalent conversion by reflux in toluene afforded the corresponding core-fluorescent four-armed star and dicyclic 8-shaped poly(THF)s, (Ia and Ib, respectively) for the use of single-molecule fluorescence microscopy measurements.

  6. Optimization of territory control of the mail carrier by using Hungarian methods

    Science.gov (United States)

    Supian, S.; Wahyuni, S.; Nahar, J.; Subiyanto

    2018-03-01

    In this paper, the territory control of the mail carrier from the central post office Bandung in delivering the package to the destination location was optimized by using Hungarian method. Sensitivity analysis against data changes that may occur was also conducted. The sampled data in this study are the territory control of 10 mail carriers who will be assigned to deliver mail package to 10 post office delivery centers in Bandung. The result of this research is the combination of territory control optimal from 10 mail carriers as follows: mail carrier 1 to Cikutra, mail carrier 2 to Ujung Berung, mail carrier 3 to Dayeuh Kolot, mail carrier 4 to Padalarang, mail carrier 5 to Situ Saeur, mail carrier 6 to Cipedes, mail carrier 7 to Cimahi, mail carrier 8 to Soreang, mail carrier 9 to Asia-Afrika, mail carrier 10 to Cikeruh. Based on this result, manager of the central post office Bandung can make optimal decisions to assign tasks to their mail carriers.

  7. Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm

    Directory of Open Access Journals (Sweden)

    Yang-Sub Lee

    2015-01-01

    Full Text Available Background: The aim of this study was to investigate clinical applications of mobile C-arms and consequent radiation risk, to increase medical attention on radiation protection, and to provide basic data for safe radiation use in the operating room. Materials and Methods: In this study, a total of 374 surgical operations, conducted using a portable fluoroscopic X-ray system from January to March of 2013, were analyzed. Dose summaries produced by the General Electric C-arm and data elements in digital imaging and communications in the medicine header of Ziehm C-arm, fluoroscopy time were used to obtain dose-area product (DAP and effective dose. Corresponding mean and maximum values were calculated, and the resulting data on the frequency of application, fluoroscopy time, DAP, and effective dose were compared and analyzed in terms of surgical specialty and operation types. Results: Orthopedic surgery was the most frequent with 165 cases (44.1%. The highest DAP value and effective dose were found in liver transplant among surgical specialty fields, with mean values of 2.90 ± 3.76 mGy∙m 2 and 58 ± 75.2 mSv, respectively (P = 0.0001. The highest DAP value and effective dose were observed in intra-operative mesenteric portography among types of surgery, showing mean values of 2.90 ± 3.81 mGy∙m 2 and 58.03 ± 76.24 mSv, respectively (P = 0.0001. Conclusion: Because DAP varies significantly across surgical specialties and types of operation, aggressive efforts to understand the effects of radiation dose is critical for radiation protection from intra-operative use of mobile C-arms.

  8. Plasmon-induced carrier polarization in semiconductor nanocrystals

    Science.gov (United States)

    Yin, Penghui; Tan, Yi; Fang, Hanbing; Hegde, Manu; Radovanovic, Pavle V.

    2018-06-01

    Spintronics1 and valleytronics2 are emerging quantum electronic technologies that rely on using electron spin and multiple extrema of the band structure (valleys), respectively, as additional degrees of freedom. There are also collective properties of electrons in semiconductor nanostructures that potentially could be exploited in multifunctional quantum devices. Specifically, plasmonic semiconductor nanocrystals3-10 offer an opportunity for interface-free coupling between a plasmon and an exciton. However, plasmon-exciton coupling in single-phase semiconductor nanocrystals remains challenging because confined plasmon oscillations are generally not resonant with excitonic transitions. Here, we demonstrate a robust electron polarization in degenerately doped In2O3 nanocrystals, enabled by non-resonant coupling of cyclotron magnetoplasmonic modes11 with the exciton at the Fermi level. Using magnetic circular dichroism spectroscopy, we show that intrinsic plasmon-exciton coupling allows for the indirect excitation of the magnetoplasmonic modes, and subsequent Zeeman splitting of the excitonic states. Splitting of the band states and selective carrier polarization can be manipulated further by spin-orbit coupling. Our results effectively open up the field of plasmontronics, which involves the phenomena that arise from intrinsic plasmon-exciton and plasmon-spin interactions. Furthermore, the dynamic control of carrier polarization is readily achieved at room temperature, which allows us to harness the magnetoplasmonic mode as a new degree of freedom in practical photonic, optoelectronic and quantum-information processing devices.

  9. Beyond arms control? Looking for the lost paradigm.

    International Nuclear Information System (INIS)

    Dahan, P.

    2002-01-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  10. Comparison of upper arm and forearm blood pressure.

    Science.gov (United States)

    Domiano, Kathy L; Hinck, Susan M; Savinske, Debra L; Hope, Kathryn L

    2008-11-01

    The upper arm is the primary site used to obtain a blood pressure measurement (BPM); however, when it is not possible to use the upper arm, the forearm is a commonly used alternate site. This study determines if there is a significant difference between upper arm and forearm BPMs among adults and examines the relationship of participant characteristics to the BPM difference. A convenience sample was recruited from a low-income, independent-living, 104-apartment complex in the Midwest. Of the 106 participants, 64% were female and 89% were White. Ages ranged from 20 to 85 years (M = 50.7). The investigators calculated the BMIs (range = 18 to 42, M = 29.3, SD = 5.4) for the 89% (n = 94) of participants who reported their weight. The forearm tended to have higher BPMs than the upper arm (M difference = 4.0 mm Hg systolic, 2.3 mm Hg diastolic). However, site differences were greatest for men, obese adults, and middle aged (36 to 65) adults.

  11. Protection switching for carrier ethernet multicast

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Wessing, Henrik; Berger, Michael Stübert

    2010-01-01

    This paper addresses network survivability for IPTV multicast transport in Carrier Ethernet networks. The impact of link failures is investigated and suggestions for intelligent multicast resilience schemes are proposed. In particular, functions of the multicast tree are integrated with the Carri...... recovery path length, recovery time, number of branch nodes and operational complexity. The integrated approach therefore shows significant potential to increase the QoE for IPTV users in case of network failures and recovery actions.......This paper addresses network survivability for IPTV multicast transport in Carrier Ethernet networks. The impact of link failures is investigated and suggestions for intelligent multicast resilience schemes are proposed. In particular, functions of the multicast tree are integrated with the Carrier...

  12. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements.

    Science.gov (United States)

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  exoskeleton, successfully carried a ball to a goal in all 10 trials. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  13. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements

    Science.gov (United States)

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Objective. Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Approach. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Main results. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  exoskeleton, successfully carried a ball to a goal in all 10 trials. Significance. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  14. Carrier screening in the era of expanding genetic technology.

    Science.gov (United States)

    Arjunan, Aishwarya; Litwack, Karen; Collins, Nick; Charrow, Joel

    2016-12-01

    The Center for Jewish Genetics provides genetic education and carrier screening to individuals of Jewish descent. Carrier screening has traditionally been performed by targeted mutation analysis for founder mutations with an enzyme assay for Tay-Sachs carrier detection. The development of next-generation sequencing (NGS) allows for higher detection rates regardless of ethnicity. Here, we explore differences in carrier detection rates between genotyping and NGS in a primarily Jewish population. Peripheral blood samples or saliva samples were obtained from 506 individuals. All samples were analyzed by sequencing, targeted genotyping, triplet-repeat detection, and copy-number analysis; the analyses were carried out at Counsyl. Of 506 individuals screened, 288 were identified as carriers of at least 1 condition and 8 couples were carriers for the same disorder. A total of 434 pathogenic variants were identified. Three hundred twelve variants would have been detected via genotyping alone. Although no additional mutations were detected by NGS in diseases routinely screened for in the Ashkenazi Jewish population, 26.5% of carrier results and 2 carrier couples would have been missed without NGS in the larger panel. In a primarily Jewish population, NGS reveals a larger number of pathogenic variants and provides individuals with valuable information for family planning.Genet Med 18 12, 1214-1217.

  15. Tracking Ultrafast Carrier Dynamics in Single Semiconductor Nanowire Heterostructures

    Directory of Open Access Journals (Sweden)

    Taylor A.J.

    2013-03-01

    Full Text Available An understanding of non-equilibrium carrier dynamics in silicon (Si nanowires (NWs and NW heterostructures is very important due to their many nanophotonic and nanoelectronics applications. Here, we describe the first measurements of ultrafast carrier dynamics and diffusion in single heterostructured Si nanowires, obtained using ultrafast optical microscopy. By isolating individual nanowires, we avoid complications resulting from the broad size and alignment distribution in nanowire ensembles, allowing us to directly probe ultrafast carrier dynamics in these quasi-one-dimensional systems. Spatially-resolved pump-probe spectroscopy demonstrates the influence of surface-mediated mechanisms on carrier dynamics in a single NW, while polarization-resolved femtosecond pump-probe spectroscopy reveals a clear anisotropy in carrier lifetimes measured parallel and perpendicular to the NW axis, due to density-dependent Auger recombination. Furthermore, separating the pump and probe spots along the NW axis enabled us to track space and time dependent carrier diffusion in radial and axial NW heterostructures. These results enable us to reveal the influence of radial and axial interfaces on carrier dynamics and charge transport in these quasi-one-dimensional nanosystems, which can then be used to tailor carrier relaxation in a single nanowire heterostructure for a given application.

  16. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  17. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  18. Modeling of carrier dynamics in quantum-well electroabsorption modulators

    DEFF Research Database (Denmark)

    Højfeldt, Sune; Mørk, Jesper

    2002-01-01

    We present a comprehensive drift-diffusion-type electroabsorption modulator (EAM) model. The model allows us to investigate both steady-state properties and to follow the sweep-out of carriers after pulsed optical excitation. Furthermore, it allows for the investigation of the influence that vari...... in the field near each well affect the escape of carriers from that well. Finally, we look at the influence that the separate-confinement heterostructure barriers have on the carrier sweep-out....... that various design parameters have on the device properties, in particular how they affect the carrier dynamics and the corresponding field dynamics. A number of different types of results are presented. We calculate absorption spectra and steady-state field screening due to carrier pile-up at the separate......-confinement heterobarriers. We then move on to look at carrier sweep-out upon short-pulse optical excitation. For a structure with one well, we analyze how the well position affects the carrier sweep-out and the absorption recovery. We calculate the field dynamics in a multiquantum-well structure and discuss how the changes...

  19. Carrier tracking by smoothing filter can improve symbol SNR

    Science.gov (United States)

    Hurd, W. J.; Pomalaza-Raez, C. A.

    1985-01-01

    The potential benefit of using a smoothing filter to estimate carrier phase over use of phase locked loops (PLL) is determined. Numerical results are presented for the performance of three possible configurations of the deep space network advanced receiver. These are residual carrier PLL, sideband aided residual carrier PLL, and finally sideband aiding with a Kalman smoother. The average symbol signal to noise ratio (CNR) after losses due to carrier phase estimation error is computed for different total power SNRs, symbol rates and symbol SNRs. It is found that smoothing is most beneficial for low symbol SNRs and low symbol rates. Smoothing gains up to 0.4 dB over a sideband aided residual carrier PLL, and the combined benefit of smoothing and sideband aiding relative to a residual carrier loop is often in excess of 1 dB.

  20. Radon generator and the method of radium carrier fabrication

    International Nuclear Information System (INIS)

    Czerski, B.

    1992-01-01

    The radon generator construction and the method of radium carrier fabrication has been the subject of the patent. The generator is a cylindrical vessel with gas valves system and two filters inside. Between them the radium carrier has been located. As a carrier polyurethane foam has been used. The carrier is obtained in a generator vessel from polyester resin in the presence of activated mixture of engine oil, zinc-organic catalyst and toluene. To the obtained mixture the radium chloride in the solution of hydrochloric acid is added. The carrier foam is produced by mechanical stirring of substrates inside the vessel and drying in 50 C in a heater. 1 fig

  1. Controlling Flexible Robot Arms Using High Speed Dynamics Process

    Science.gov (United States)

    Jain, Abhinandan (Inventor)

    1996-01-01

    A robot manipulator controller for a flexible manipulator arm having plural bodies connected at respective movable hinges and flexible in plural deformation modes corresponding to respective modal spatial influence vectors relating deformations of plural spaced nodes of respective bodies to the plural deformation modes, operates by computing articulated body quantities for each of the bodies from respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables, and computing modal deformation accelerations and hinge accelerations is carried out for each one of the bodies beginning with the outermost body by computing a residual body force from a residual body force of a previous body and from the vector of deformation and hinge configuration variables, computing a resultant hinge acceleration from the body force, the residual body force and the articulated hinge inertia, and revising the residual body force modal body acceleration.

  2. Chaotic evolution of arms races

    Science.gov (United States)

    Tomochi, Masaki; Kono, Mitsuo

    1998-12-01

    A new set of model equations is proposed to describe the evolution of the arms race, by extending Richardson's model with special emphases that (1) power dependent defensive reaction or historical enmity could be a motive force to promote armaments, (2) a deterrent would suppress the growth of armaments, and (3) the defense reaction of one nation against the other nation depends nonlinearly on the difference in armaments between two. The set of equations is numerically solved to exhibit stationary, periodic, and chaotic behavior depending on the combinations of parameters involved. The chaotic evolution is realized when the economic situation of each country involved in the arms race is quite different, which is often observed in the real world.

  3. The rejection of the comprehensive nuclear test ban treaty by the US Senate: a reverse for the nuclear arms control?

    International Nuclear Information System (INIS)

    Sitt, B.

    2000-01-01

    On October 13, 1999, after a hasty debate, the US Senate rejected the comprehensive nuclear test ban treaty (CTBT) signed 3 years ago. This article analyses this event with respect to the US domestic context (discussions at the Senate, reaction of the Presidency) and with respect to the international context (international reactions, future of the treaty, consequences on arms control policy). (J.S.)

  4. 49 CFR 397.67 - Motor carrier responsibility for routing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Motor carrier responsibility for routing. 397.67 Section 397.67 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS...

  5. Annealing behaviour of excess carriers in neutron-transmutation-doped silicon

    International Nuclear Information System (INIS)

    Maekawa, T.; Nogami, S.; Inoue, S.

    1993-01-01

    In neutron-transmutation-doped silicon wafers excess carriers are clearly generated over the transmuted phosphorus atoms. The generation occurs for annealing temperatures above 900 o C. The maximum percentage of excess carriers obtained is about 24.5% of the final carrier concentration. Due to the difference in energy of generation and removal, the excess carriers can be removed by annealing above 800 o C. The radiation damage responsible for generation of excess carriers is fairly thermostable in the range of annealing temperatures below 800 o C. From deep-level transient spectroscopy measurements, it is found that the radiation damage remains insensitive to changes in carrier concentration. The activation energies of excess carrier generation and removal are estimated from the analysis of the thermal and temporal behaviours of radiation damage in the annealing process. (Author)

  6. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  7. The arms race control; Le controle de la course aux armements

    Energy Technology Data Exchange (ETDEWEB)

    Nemo, J.

    2010-07-15

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  8. Beyond arms control? Looking for the lost paradigm..; Au-dela de l'arms control? A la recherche du paradigme perdu..

    Energy Technology Data Exchange (ETDEWEB)

    Dahan, P

    2002-07-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  9. Feelings Associated with Being a Carrier and Characteristics of Reproductive Decision Making in Women Known to Be Carriers of X-linked Conditions.

    Science.gov (United States)

    Kay, Elizabeth; Kingston, Helen

    2002-03-01

    Qualitative data were collected from 14 women known to be carriers of an X-linked condition associated with 'serious' disability on feelings about being a carrier and impact on reproductive decisions. Guilt and responsibility were commonly expressed by carriers about issues surrounding pregnancy. Personal experience of the condition influenced their approach to reproductive decisions. Those who had lived with an affected brother were more concrete in their decisions to avoid having an affected child compared to those with less personal experience of the condition. It is concluded that feelings of guilt associated with difficult reproductive decisions are reflected in the strong sense of responsibility attached to being a carrier. Personal experience of the condition has a clear influence on reproductive decisions of X-linked carriers.

  10. Crystal engineering of lactose using electrospray technology: carrier for pulmonary drug delivery.

    Science.gov (United States)

    Patil, Sharvil; Mahadik, Abhijeet; Nalawade, Pradeep; More, Priyesh

    2017-12-01

    Dry powder inhalers (DPIs) consisting of a powder mixture containing coarse carrier particles (generally lactose) and micronized drug particles are used for lung drug delivery. The effective drug delivery to the lungs depends on size and shape of carrier particles. Thus, various methods have been proposed for engineering lactose particles to enhance drug delivery to lungs. The objective of current work was to assess suitability of electrospray technology toward crystal engineering of lactose. Further, utility of the prepared lactose particles as a carrier in DPI was evaluated. Saturated lactose solutions were electrosprayed to obtain electrosprayed lactose (EL) particles. The polymorphic form of EL was determined using Fourier transform infrared spectroscopy, powder X-ray diffractometry, and differential scanning calorimetry. In addition, morphological, surface textural, and flow properties of EL were determined using scanning electron microscopy and Carr's index, respectively. The aerosolization properties of EL were determined using twin-stage impinger and compared with commercial lactose particles [Respitose ® (SV003, Goch, Germany)] used in DPI formulations. EL was found to contain both isomers (α and β) of lactose having flow properties comparable to Respitose ® (SV003). In addition, the aerosolization properties of EL were found to be significantly improved when compared to Respitose ® (SV003) which could be attributed to morphological (high elongation ratio) and surface characteristic (smooth surface) alterations induced by electrospray technology. Electrospray technology can serve as an alternative technique for continuous manufacturing of engineered lactose particles which can be used as a carrier in DPI formulations.

  11. Coat of Arms.

    Science.gov (United States)

    Smith, Bryan

    1998-01-01

    Describes an activity, the "coat of arms," that can serve as an ice-breaker or warm-up for the first day of an English-as-a-Second/Foreign-Language class, as a motivating start to the week, or act as an innovative segue between skill lessons. The technique can be adapted for students ranging from elementary school to adult language learners of all…

  12. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  13. Evaluation of patterns of liver toxicity in patients on antiretroviral and anti-tuberculosis drugs: a prospective four arm observational study in ethiopian patients.

    Directory of Open Access Journals (Sweden)

    Getnet Yimer

    Full Text Available OBJECTIVES: To evaluate the incidence, type, severity and predictors of antiretroviral and/or anti-tuberculosis drugs induced liver injury (DILI. METHODS: A total of 1,060 treatment naive patients were prospectively enrolled into four treatment groups: HIV patients receiving efavirenz based HAART alone (Arm-1; TB-HIV co-infected patients with CD4≤200 cells/μL, receiving concomitant rifampicin based anti-TB and efavirenz based HAART (Arm-2; TB-HIV co-infected patients with CD4>200 cells/μL, receiving anti-TB alone (Arm-3; TB patients taking rifampicin based anti-TB alone (Arm-4. Liver enzyme levels were monitored at baseline, 1st, 2nd, 4th, 8th, 12th and 24th weeks during treatment. CD4 and HIV viral load was measured at baseline, 24th and 48th weeks. Data were analyzed using multivariate Cox Proportional Hazards Model. RESULTS: A total of 159 patients (15% developed DILI with severity grades 1, 2, 3 and 4 of 53.5%, 32.7%, 11.3% and 2.5% respectively. The incidence of cholestatic, hepatocellular or mixed pattern was 61%, 15% and 24%, respectively. Incidence of DILI was highest in Arm-2 (24.2%>Arm-3 (10.8%>Arm-1 (8.8%>Arm-4 (2.9%. Concomitant anti-TB-HIV therapy increased the risk of DILI by 10-fold than anti-TB alone (p<0.0001. HIV co-infection increased the risk of anti-TB DILI by 4-fold (p = 0.004. HAART associated DILI was 3-fold higher than anti-TB alone, (p = 0.02. HAART was associated with cholestatic and grade 1 DILI whereas anti-TB therapy was associated with hepatocellular and grade ≥ 2. Treatment type, lower CD4, platelet, hemoglobin, higher serum AST and direct bilirubin levels at baseline were significant DILI predictors. There was no effect of DILI on immunologic recovery or virologic suppression rate of HAART. CONCLUSION: HAART associated DILI is mainly cholestatic and mild whereas hepatocellular or mixed pattern with high severity grade is more common in anti-tuberculosis DILI. TB-HIV co-infection, disease severity

  14. Cancer risk and survival in path_MMR carriers by gene and gender up to 75 years of age

    DEFF Research Database (Denmark)

    Møller, Pål; Seppälä, Toni; Bernstein, Inge

    2017-01-01

    BACKGROUND: Most patients with path_MMR gene variants (Lynch syndrome (LS)) now survive both their first and subsequent cancers, resulting in a growing number of older patients with LS for whom limited information exists with respect to cancer risk and survival. OBJECTIVE AND DESIGN......%, duodenum 67%, stomach 61%, bile duct 29%, brain 22% and pancreas 0%. Path_PMS2 carriers had lower risk for cancer. CONCLUSION: Carriers of different path_MMR variants exhibit distinct patterns of cancer risk and survival as they age. Risk estimates for counselling and planning of surveillance and treatment...

  15. Hysteresis of targeting civilians in armed conflicts

    OpenAIRE

    Uih Ran Lee

    2015-01-01

    This article explores warring groups’ intentional targeting behavior against civilians, a strictly prohibited war strategy by international norms. Using dynamic panel regressions run on a comprehensive dataset of contemporary warfare which covers 22 years (1989-2010), I find that warring actors, both sovereign states and formally organized armed groups, behave systematically in terms of civilian targeting when they are involved in prolonged armed conflict (15-22 years). Warring actors’ lethal...

  16. 14 CFR 158.69 - Recordkeeping and auditing: Collecting carriers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Recordkeeping and auditing: Collecting carriers. 158.69 Section 158.69 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....69 Recordkeeping and auditing: Collecting carriers. (a) Collecting carriers shall establish and...

  17. 49 CFR 373.101 - Motor carrier bills of lading.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Motor carrier bills of lading. 373.101 Section 373.101 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS RECEIPTS AND...

  18. Tinea capitis: study of asymptomatic carriers and sick adolescents, adults and elderly who live with children with the disease

    Directory of Open Access Journals (Sweden)

    BERGSON Christiane Loureiro

    2001-01-01

    Full Text Available Tinea capitis is a dermatophyte infection that occurs mainly in childhood; there are few reports, in Brazil, in adolescents and adults. The detection of asymptomatic carriers is of great importance in the disease control. From February 1998 to February 1999, a study was performed at the outpatient Dermatologic Unit of Instituto de Puericultura e Pediatria Martagão Gesteira (Universidade Federal do Rio de Janeiro, Brasil to verify the frequency of asymptomatic carriers and tinea capitis between 79 adolescents, adults and elderly who lived in the same household of 56 children (0-12 years with tinea capitis. Of these, one female and one male adults (2.5% were asymptomatic carriers and the cultures revealed Trichophyton tonsurans and Microsporum canis respectively. One female adolescent and two female adults (3.8% had tinea capitis and all cultures revealed Trichophyton tonsurans. The study has shown that adolescents and adults who live in the same household of children with tinea capitis may be sick or asymptomatic carriers.

  19. Trimethyl and carboxymethyl chitosan carriers for bio-active polymer-inorganic nanocomposites.

    Science.gov (United States)

    Geisberger, Georg; Gyenge, Emina Besic; Maake, Caroline; Patzke, Greta R

    2013-01-02

    The carrier properties of carboxymethyl chitosan (CMC) and trimethyl chitosan (TMC) in combination with polyoxometalates (POMs) as inorganic drug prototypes are compared with respect to the influence of polymer matrix charge and structure on the emerging composites. A direct crosslinking approach with TMC and K(6)H(2)[CoW(11)TiO(40)]·13H(2)O ({CoW(11)TiO(40)}) as a representative anticancer POM affords nanocomposites with a size range of 50-90nm. The obtained POM-chitosan composites are characterized with a wide range of analytical methods, and POM encapsulation into positively charged TMC brings forward different nanocomposite morphologies and properties than CMC as a carrier material. Furthermore, uptake of fluorescein isothiocyanate (FITC) labeled POM-CMC and POM-TMC by HeLa cells was monitored, and the influence of chlorpromazine (CP) as inhibitor of the clathrin mediated pathway revealed different cellular uptake behavior of composites and pristine carriers. TMC/{CoW(11)TiO(40)} nanocomposites are taken up by HeLa cells after short incubation times around 30 min at low concentrations. The anticancer activity of pristine {CoW(11)TiO(40)} and its TMC-nanocomposites was investigated in vitro with MTT assays and compared to a reference POM. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Treatment of cyanide wastewater by bulk liquid membrane using tricaprylamine as a carrier.

    Science.gov (United States)

    Li, Guoping; Xue, Juanqin; Liu, Nina; Yu, Lihua

    2016-01-01

    The transport of cyanide from wastewater through a bulk liquid membrane (BLM) containing tricaprylamine (TOA) as a carrier was studied. The effect of cyanide concentration in the feed solution, TOA concentration in the organic phase, the stirring speed, NaOH concentration in the stripping solution and temperature on cyanide transport was determined through BLM. Mass transfer of cyanide through BLM was analyzed by following the kinetic laws of two consecutive irreversible first-order reactions, and the kinetic parameters (k(1), k(2), R(m)(max), t(max), J(a)(max), J(d)(max)) were also calculated. Apparently, increase in membrane entrance (k(1)) and exit rate (k(2)) constants was accompanied by a rise in temperature. The values of activation energies were obtained as 35.6 kJ/mol and 18.2 kJ/mol for removal and recovery, respectively. These values showed that both removal and recovery steps in cyanide transport is controlled by the rate of the chemical complexation reaction. The optimal reaction conditions were determined by BLM using trioctylamine as the carrier: feed phase: pH 4, carrier TOA possession ratio in organic phase: 2% (V/V), stripping phase concentration of NaOH: 1% (W/V), reaction time: 60 min, stirring speed: 250 r/min. Under the above conditions, the removal rate was up to 92.96%. The experiments demonstrated that TOA was a good carrier for cyanide transport through BLM in this study.