WorldWideScience

Sample records for resonance parameter evaluations

  1. Average resonance parameters evaluation for actinides

    Energy Technology Data Exchange (ETDEWEB)

    Porodzinskij, Yu.V.; Sukhovitskij, E.Sh. [Radiation Physics and Chemistry Problems Inst., Minsk-Sosny (Belarus)

    1997-03-01

    New evaluated <{Gamma}{sub n}{sup 0}> and values for {sup 238}U, {sup 237}Np, {sup 243}Cm, {sup 245}Cm, {sup 246}Cm and {sup 241}Am nuclei in the resolved resonance region are presented. The applied method based on the idea that experimental resonance missing results in correlated changes of reduced neutron widths and level spacings distributions is discussed. (author)

  2. New evaluation of 238U neutron resonance parameters

    International Nuclear Information System (INIS)

    Derrien, Herve; Leal, Luiz C.; Larson, Nancy M.

    2003-01-01

    The neutron resonance parameters of 238 U were obtained in the energy range 1 keV to 20 keV from a SAMMY Reich-Moore analysis of high resolution transmission measurements performed at ORELA. In the energy range 1 keV to 10 keV, the analysis used as prior values the ENDF/B-VI resonance parameters. The analysis in the energy range 10 keV to 20 keV resulted in the creation of a set of resonance parameters for the representation of the cross section in this energy range. The results are compared to the ENDF/B-VI evaluation. Some statistical properties of the new resonance parameters are examined. (author)

  3. Nuclear data project in Korea and resonance parameter evaluation of fission products

    International Nuclear Information System (INIS)

    Chang, Jonghwa; Oh, Soo-Youl

    2000-01-01

    Nuclear data activities in the fields of evaluation, processing, measurement, and service in Korea are presented in this paper. As one of the current activities, the neutron resonance parameters for stable or long-lived nineteen fission products have been evaluated and the results are presented here. (author)

  4. Evaluation of covariances for resolved resonance parameters of 235U, 238U, and 239Pu in JENDL-3.2

    International Nuclear Information System (INIS)

    Kawano, Toshihiko; Shibata, Keiichi

    2003-02-01

    Evaluation of covariances for resolved resonance parameters of 235 U, 238 U, and 239 Pu was carried out. Although a large number of resolved resonances are observed for major actinides, uncertainties in averaged cross sections are more important than those in resonance parameters in reactor calculations. We developed a simple method which derives a covariance matrix for the resolved resonance parameters from uncertainties in the averaged cross sections. The method was adopted to evaluate the covariance data for some important actinides, and the results were compiled in the JENDL-3.2 covariance file. (author)

  5. Resonance parameter and covariance evaluation for 16O up to 6 MeV

    Directory of Open Access Journals (Sweden)

    Leal Luiz

    2016-01-01

    Full Text Available A resolved resonance evaluation was performed for 16O in the energy range 0 eV to 6 MeV using the computer code SAMMY resulting in a set of resonance parameters (RPs that describes well the experimental data used in the evaluation. A RP covariance matrix (RPC was also generated. The RP were converted to the evaluated nuclear data file format using the R-Matrix Limited format and the compact format was used to represent the RPC. In contrast to the customary use of RP, which are frequently intended for the generation of total, capture, and scattering cross sections only, the present RP evaluation permits the computation of angle dependent cross sections. Furthermore, the RPs are capable of representing the (n, α cross section from the energy threshold (2.354 MeV of the (n, α reaction to 6 MeV. The intent of this paper is to describe the procedures used in the evaluation of the RP and RPC, the use of the RPC in benchmark calculations and to assess the impact of the 16O nuclear data uncertainties in the calculate dkeff for critical benchmark experiments.

  6. Review of 241 Pu resonance parameters

    International Nuclear Information System (INIS)

    Derrien, H.

    1981-10-01

    The status of 241 Pu resonance parameters is reviewed. The most important recent results are compared in some energy ranges, both from single level and multilevel point of view. It appears that an accurate set of resonance parameters is not still obtained for a general description of the cross-sections in the resonance region. Some recommendations are given for further experiments or evaluations

  7. Low field magnetic resonance imaging of the lumbar spine: Reliability of qualitative evaluation of disc and muscle parameters

    DEFF Research Database (Denmark)

    Sørensen, Joan Solgaard; Kjaer, Per; Jensen, Tue Secher

    2006-01-01

    PURPOSE: To determine the intra- and interobserver reliability in grading disc and muscle parameters using low-field magnetic resonance imaging (MRI). MATERIAL AND METHODS: MRI scans of 100 subjects representative of the general population were evaluated blindly by two radiologists. Criteria......: Convincing reliability was found in the evaluation of disc- and muscle-related MRI variables....

  8. The LIPAR-5 resonance parameter library

    International Nuclear Information System (INIS)

    Abagyan, L.P.

    1997-08-01

    The LIPAR-5 neutron resolved resonance parameter library has been elaborated. It contains data for 94 isotopes. The author's evaluations are included in LIPAR. Other authors' results are also included after re-evaluation. The codes used for the evaluation are described briefly. Tables of results are included for every isotope: the boundaries of the resolved resonance region, the numbers of s- and p-resonances, the thermal neutron partial cross-sections and the resonance integrals. The parameters are presented in ENDF/B-6 format. LIPAR is part of the nuclear data library of the MCU Monte Carlo code for neutron transport calculations. LIPAR was verified by comparing the benchmark experiment and Monte Carlo calculation results. (author). 44 refs, 6 tabs

  9. Evaluation of resonance parameters of Mo, Tc, Te, Ba, La, Ce, Pr, Nd, Pm, Sm and Eu isotopes for JENDL-2 fission product file

    International Nuclear Information System (INIS)

    Kikuchi, Yasuyuki; Togawa, Orihiko; Nakagawa, Tsuneo

    1986-03-01

    The resonance parameters of 39 fission product nuclides have been evaluated. The present work is a part of the evaluation of 100 fission product nuclei for JENDL-2 by Japanese Nuclear Data Committee. All the available experimental data were collected, stored in REPSTOR system and compared with one another. The evaluation was made on the basis of the experimental data. The precise description of the evaluation is given in this report. The presently evaluated resonance parameters are tabulated in Appendix with the experimental data. (author)

  10. Resolved resonance parameters for 236Np

    International Nuclear Information System (INIS)

    Morogovskij, G.B.; Bakhanovich, L.A.

    2002-01-01

    Multilevel Breit-Wigner parameters were obtained for fission cross-section representation in the 0.01-33 eV energy region from evaluation of a 236 Np experimental fission cross-section in the resolved resonance region. (author)

  11. Integral data analysis for resonance parameters determination

    International Nuclear Information System (INIS)

    Larson, N.M.; Leal, L.C.; Derrien, H.

    1997-09-01

    Neutron time-of-flight experiments have long been used to determine resonance parameters. Those resonance parameters have then been used in calculations of integral quantities such as Maxwellian averages or resonance integrals, and results of those calculations in turn have been used as a criterion for acceptability of the resonance analysis. However, the calculations were inadequate because covariances on the parameter values were not included in the calculations. In this report an effort to correct for that deficiency is documented: (1) the R-matrix analysis code SAMMY has been modified to include integral quantities of importance, (2) directly within the resonance parameter analysis, and (3) to determine the best fit to both differential (microscopic) and integral (macroscopic) data simultaneously. This modification was implemented because it is expected to have an impact on the intermediate-energy range that is important for criticality safety applications

  12. Neutron resonance parameters of CM isotopes

    International Nuclear Information System (INIS)

    Belanova, T.S.; Kolesov, A.G.; Poruchikov, V.A.

    1977-01-01

    The total neutron cross sections of isotopes 244, 245, 246, 248 Curium have been measured on reactor CM-2 using the time-of-flight method. Single-level Breit-Wigner resonance parameters: energy E 0 , neutron width 2g GITAn, total width GITA, total neutron cross section in resonance sigma 0 have been obtained by the shape and area methods

  13. Resonance parameter analysis with SAMMY

    International Nuclear Information System (INIS)

    Larson, N.M.; Perey, F.G.

    1988-01-01

    The multilevel R-matrix computer code SAMMY has evolved over the past decade to become an important analysis tool for neutron data. SAMMY uses the Reich-Moore approximation to the multilevel R-matrix and includes an optional logarithmic parameterization of the external R-function. Doppler broadening is simulated either by numerical integration using the Gaussian approximation to the free gas model or by a more rigorous solution of the partial differential equation equivalent to the exact free gas model. Resolution broadening of cross sections and derivatives also has new options that more accurately represent the experimental situation. SAMMY treats constant normalization and some types of backgrounds directly and treats other normalizations and/or backgrounds with the introduction of user-generated partial derivatives. The code uses Bayes' method as an efficient alternative to least squares for fitting experimental data. SAMMY allows virtually any parameter to be varied and outputs values, uncertainties, and covariance matrix for all varied parameters. Versions of SAMMY exist for VAX, FPS, and IBM computers

  14. Multilevel resonance parameters of 241Pu

    International Nuclear Information System (INIS)

    Weston, L.W.; Todd, J.H.

    1978-01-01

    The data previously reported by the authors on the neutron fission and capture cross sections of 241 Pu were simultaneously fit with the Adler formalism to obtain multilevel resonance parameters. The neutron energy range of the fit was 0.01 to 100 eV. The 241 Pu cross sections in the resonance region of neutron energies are complex, and the Adler parameters present an efficient method of representing these cross sections, which are important for plutonium-fueled reactors. The parameters represent the data to an accuracy within the quoted experimental errors. 5 figures, 2 tables

  15. Definition of pertinent parameters for the evaluation of articular cartilage repair tissue with high-resolution magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marlovits, Stefan; Striessnig, Gabriele; Resinger, Christoph T.; Aldrian, Silke M.; Vecsei, Vilmos; Imhof, Herwig; Trattnig, Siegfried

    2004-01-01

    To evaluate articular cartilage repair tissue after biological cartilage repair, we propose a new technique of non-invasive, high-resolution magnetic resonance imaging (MRI) and define a new classification system. For the definition of pertinent variables the repair tissue of 45 patients treated with three different techniques for cartilage repair (microfracture, autologous osteochondral transplantation, and autologous chondrocyte transplantation) was analyzed 6 and 12 months after the procedure. High-resolution imaging was obtained with a surface phased array coil placed over the knee compartment of interest and adapted sequences were used on a 1 T MRI scanner. The analysis of the repair tissue included the definition and rating of nine pertinent variables: the degree of filling of the defect, the integration to the border zone, the description of the surface and structure, the signal intensity, the status of the subchondral lamina and subchondral bone, the appearance of adhesions and the presence of synovitis. High-resolution MRI, using a surface phased array coil and specific sequences, can be used on every standard 1 or 1.5 T MRI scanner according to the in-house standard protocols for knee imaging in patients who have had cartilage repair procedures without substantially prolonging the total imaging time. The new classification and grading system allows a subtle description and suitable assessment of the articular cartilage repair tissue

  16. Influence of resonance parameters' correlations on the resonance integral uncertainty; 55Mn case

    International Nuclear Information System (INIS)

    Zerovnik, Gasper; Trkov, Andrej; Capote, Roberto; Rochman, Dimitri

    2011-01-01

    For nuclides with a large number of resonances the covariance matrix of resonance parameters can become very large and expensive to process in terms of the computation time. By converting covariance matrix of resonance parameters into covariance matrices of background cross-section in a more or less coarse group structure a considerable amount of computer time and memory can be saved. The question is how important is the information that is discarded in the process. First, the uncertainty of the 55 Mn resonance integral was estimated in narrow resonance approximation for different levels of self-shielding using Bondarenko method by random sampling of resonance parameters according to their covariance matrices from two different 55 Mn evaluations: one from Nuclear Research and Consultancy Group NRG (with large uncertainties but no correlations between resonances), the other from Oak Ridge National Laboratory (with smaller uncertainties but full covariance matrix). We have found out that if all (or at least significant part of the) resonance parameters are correlated, the resonance integral uncertainty greatly depends on the level of self-shielding. Second, it was shown that the commonly used 640-group SAND-II representation cannot describe the increase of the resonance integral uncertainty. A much finer energy mesh for the background covariance matrix would have to be used to take the resonance structure into account explicitly, but then the objective of a more compact data representation is lost.

  17. Evaluation of Effective Parameters on Quality of Magnetic Resonance Imaging-computed Tomography Image Fusion in Head and Neck Tumors for Application in Treatment Planning

    Directory of Open Access Journals (Sweden)

    Atefeh Shirvani

    2017-01-01

    Full Text Available Background: In radiation therapy, computed tomography (CT simulation is used for treatment planning to define the location of tumor. Magnetic resonance imaging (MRI-CT image fusion leads to more efficient tumor contouring. This work tried to identify the practical issues for the combination of CT and MRI images in real clinical cases. The effect of various factors is evaluated on image fusion quality. Materials and Methods: In this study, the data of thirty patients with brain tumors were used for image fusion. The effect of several parameters on possibility and quality of image fusion was evaluated. These parameters include angles of the patient's head on the bed, slices thickness, slice gap, and height of the patient's head. Results: According to the results, the first dominating factor on quality of image fusion was the difference slice gap between CT and MRI images (cor = 0.86, P 4 cm and image fusion quality was <25%. Conclusion: The most important problem in image fusion is that MRI images are taken without regard to their use in treatment planning. In general, parameters related to the patient position during MRI imaging should be chosen to be consistent with CT images of the patient in terms of location and angle.

  18. ZZ-CENPL, Chinese Evaluated Nuclear Parameter Library. ZZ CENPL-DLS, Discrete Level Schemes and Gamma Branching Ratios Library; ZZ CENPL-FBP, Fission Barrier Parameter Library; ZZ CENPL-GDRP, Giant Dipole Resonance Parameter Library; ZZ CENPL-NLD, Nuclear Level Density Parameter Library; ZZ CENPL-MCC, Nuclear Ground State Atomic Masses Library; ZZ CENPL-OMP, Optical Model Parameter Library

    International Nuclear Information System (INIS)

    Su Zongdi

    1995-01-01

    Description of program or function: CENPL - GDRP (Giant Dipole Resonance Parameters for Gamma-Ray): - Format: special format described in documentation; - Nuclides: V, Mn, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Rh, Pd, Ag, Cd, In, Sn, Sb, Te, I, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Ho, Er, Lu, Ta, W, Re, Os, Ir, Pt, Au, Hg, Pb, Bi, Th, U, Np, Pu. - Origin: Experimental values offered by S.S. Dietrich and B.L. Berman. CENPL - FBP (Fission Barrier Parameter Sub-Library): - Format: special format described in documentation; - Nuclides: (1) 51 nuclei region from Th-230 to Cf-255, (2) 46 nuclei region from Th-229 to Cf-253, (3) 24 nuclei region from Pa-232 to Cf-253; - Origin: (1) Lynn, (2) Analysis of experimental data by Back et al., (3) Ohsawa. CENPL - DLS (Discrete level scheme and branch ratio of gamma decay: - Format: Special format described in documentation; - Origin: ENSDF - BNL. CENPL - NLD (Nuclear Level Density): - Format: Special format described in documentation; - Origin: Huang Zhongfu et al. CENPL - OMP (Optical model parameter sub-library): - Format: special format described in documentation ; - Origin: CENDL, ENDF/B-VI, JENDL-3. CENPL - MC (I) and (II) (Atomic masses and characteristic constants for nuclear ground states) : - Format: Brief table format; - Nuclides: 4760 nuclides ranging from Z=0 A=1 to Z=122 A=318. - Origin: Experimental data and systematic results evaluated by Wapstra, theoretical results calculated by Moller, ENSDF - BNL and Nuclear Wallet Cards. CENPL contains the following six sub-libraries: 1. Atomic Masses and Characteristic Constants for nuclear ground states (MCC). This data consists of calculated and in most cases also measured mass excesses, atomic masses, total binding energies, spins, parities, and half-lives of nuclear ground states, abundances, etc. for 4800 nuclides. 2. Discrete Level Schemes and branching ratios of gamma decay (DLS). The data on nuclear discrete levels are based on the Evaluated

  19. Relationship between myocardial T2* values and cardiac volumetric and functional parameters in β-thalassemia patients evaluated by cardiac magnetic resonance in association with serum ferritin levels

    Energy Technology Data Exchange (ETDEWEB)

    Liguori, Carlo, E-mail: c.liguori@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Pitocco, Francesca, E-mail: f.pitocco@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Di Giampietro, Ilenia, E-mail: i.digiampietro@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Vivo, Aldo Eros de, E-mail: devivoeros@gmail.com [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Schena, Emiliano, E-mail: e.schena@unicampus.it [Unit of Measurements and Biomedical Instrumentation, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Cianciulli, Paolo, E-mail: CIANCIULLI.PAOLO@aslrmc.it [Thalassemia Unit, Ospedale Sant Eugenio, Piazzale dell’Umanesimo 10, 00143 Rome (Italy); Zobel, Bruno Beomonte, E-mail: b.zobel@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy)

    2013-09-15

    Purpose: Myocardial T2* cardiovascular magnetic resonance provides a rapid and reproducible assessment of cardiac iron load in thalassemia patients. Although cardiac involvement is mainly characterized by left ventricular dysfunction caused by iron overload, little is known about right ventricular function. The aim of this study was to assess the relationship between T2* value in myocardium and left–right ventricular volumetric and functional parameters and to evaluate the existing associations between left–right ventricles volumetric and functional parameter, myocardial T2* values and blood ferritin levels. Materials and methods: A retrospective analysis of 208 patients with β-thalassemia major and thalassemia intermedia was performed (109 males and 99 females; mean age 37.7 ± 13 years; 143 thalassemia major, 65 thalassemia intermedia). Myocardial iron load was assessed by T2* measurements, and volumetric functions were analyzed using the steady state free precession sequence. Results: A significant correlation was observed between EFLV and T2* (p = 0.0001), EFRV and T2* (p = 0.0279). An inverse correlation was present between DVLV and T2* (p = 0.0468), SVLV and T2* (p = 0.0003), SVRV and T2* (p = 0.0001). There was no significant correlation between cardiac T2* and LV–RV mass indices. A significant correlation was observed between T2* and serum ferritin levels (p < 0.001) and between EFLV and serum ferritin (p < 0.05). Conclusion: Myocardial iron load assessed by T2* cardiac magnetic resonance is associated with deterioration in left–right ventricular function; this is more evident when T2* values fall below 14 ms. CMR appears to be a promising approach for cardiac risk evaluation in TM patients.

  20. Relationship between myocardial T2* values and cardiac volumetric and functional parameters in β-thalassemia patients evaluated by cardiac magnetic resonance in association with serum ferritin levels

    International Nuclear Information System (INIS)

    Liguori, Carlo; Pitocco, Francesca; Di Giampietro, Ilenia; Vivo, Aldo Eros de; Schena, Emiliano; Cianciulli, Paolo; Zobel, Bruno Beomonte

    2013-01-01

    Purpose: Myocardial T2* cardiovascular magnetic resonance provides a rapid and reproducible assessment of cardiac iron load in thalassemia patients. Although cardiac involvement is mainly characterized by left ventricular dysfunction caused by iron overload, little is known about right ventricular function. The aim of this study was to assess the relationship between T2* value in myocardium and left–right ventricular volumetric and functional parameters and to evaluate the existing associations between left–right ventricles volumetric and functional parameter, myocardial T2* values and blood ferritin levels. Materials and methods: A retrospective analysis of 208 patients with β-thalassemia major and thalassemia intermedia was performed (109 males and 99 females; mean age 37.7 ± 13 years; 143 thalassemia major, 65 thalassemia intermedia). Myocardial iron load was assessed by T2* measurements, and volumetric functions were analyzed using the steady state free precession sequence. Results: A significant correlation was observed between EFLV and T2* (p = 0.0001), EFRV and T2* (p = 0.0279). An inverse correlation was present between DVLV and T2* (p = 0.0468), SVLV and T2* (p = 0.0003), SVRV and T2* (p = 0.0001). There was no significant correlation between cardiac T2* and LV–RV mass indices. A significant correlation was observed between T2* and serum ferritin levels (p < 0.001) and between EFLV and serum ferritin (p < 0.05). Conclusion: Myocardial iron load assessed by T2* cardiac magnetic resonance is associated with deterioration in left–right ventricular function; this is more evident when T2* values fall below 14 ms. CMR appears to be a promising approach for cardiac risk evaluation in TM patients

  1. Phenomenological analysis of the Δ resonance parameters

    International Nuclear Information System (INIS)

    Vasan, S.S.

    1976-01-01

    The positions of the poles in the complex energy plane corresponding to the resonances Δ ++ and Δ 0 , and the associated residues, are determined by fitting the π + p and π - p hadronic phase shift data from the CARTER 73 analysis. As an illustration of the use of the Δ pole parameters, their application to the problem of parametrizing the residue function associated with the Δ Regge trajectory is considered. The input for the parametrization is given partly by the pole position and the residue of the Δ(1950), the first recurrence of the Δ(1236). These pole parameters are deduced from fits to the F 37 partial wave data from the AYED 74 phase shift analysis. Together with the Δ(1236) pole parameters, these provide information on the behavior of the Regge residue in the resonance region u less than 0 (in the context of s-channel backward scattering being dominated by u-channel Regge exchanges). Attempts to incorporate this information in parametrizations of the residue by means of real and complex functions lead to the conclusion that both the residue and the trajectory are better represented in the resonance region by complex parametrizations

  2. Rho resonance parameters from lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Dehua; Alexandru, Andrei; Molina, Raquel; Döring, Michael

    2016-08-01

    We perform a high-precision calculation of the phase shifts for $\\pi$-$\\pi$ scattering in the I = 1, J = 1 channel in the elastic region using elongated lattices with two mass-degenerate quark favors ($N_f = 2$). We extract the $\\rho$ resonance parameters using a Breit-Wigner fit at two different quark masses, corresponding to $m_{\\pi} = 226$MeV and $m_{\\pi} = 315$MeV, and perform an extrapolation to the physical point. The extrapolation is based on a unitarized chiral perturbation theory model that describes well the phase-shifts around the resonance for both quark masses. We find that the extrapolated value, $m_{\\rho} = 720(1)(15)$MeV, is significantly lower that the physical rho mass and we argue that this shift could be due to the absence of the strange quark in our calculation.

  3. Measurement of J/ψ resonance parameters

    International Nuclear Information System (INIS)

    Bai Jingzhi; Chen Guangpei; Chen Shaomin

    1995-01-01

    The cross sections of e + e - →hadrons, e + e - , μ + μ - have been measured in the vicinity of J/ψ resonance at BES/BEPC. The fit of the observed cross sections gives the new results of J/ψ resonance parameters: the partial widths to hadrons, electrons and muons are Γ h = 74.1 +- 8.1 keV, Γ e = 5.14 +- 0.39 keV and Γ μ = 5.13 +-0.52 keV respectively; the total width Γ = 84.4 +- 8.9 keV; the branching fractions Γ h /Γ = (87.8 +- 0.5)%, Γ e /Γ (6.09 +- 0.33)%, and Γ μ /Γ = (6.08 +- 0.33)%

  4. UPSILON'(10.01) resonance parameters

    International Nuclear Information System (INIS)

    Niczyporuk, B.; Zeludziewicz, T.; Chen, K.W.; Hartung, R.

    1980-09-01

    The resonance parameters of the UPSILON'(10.01) were measured using the LENA detector at the DORIS e + e - storage ring. We obtained a mass of M(UPSILON') = (10 013.6 +- 1.2 +- 10.0) MeV and an electronic width of GAMMAsub(ee)(UPSILON') = (0.53 +- 0.07sup(+0.09)sub(-0.05) keV. The upper limit set to the μ-pair branching ratio is 3.8% which implies a lower limit on the total UPSILON' widUPSILON parameters we obtain a mass difference M(UPSILON') - M(UPSILON) = (552.0 +- 1.3 +- 10.0) MeV and GAMMAsub(ee)UPSILON')/ = 0.43 +- 0.07sup(+0.05)sub(-0.00). (orig.)

  5. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  6. OPTIMIZATION OF HEMISPHERICAL RESONATOR GYROSCOPE STANDING WAVE PARAMETERS

    Directory of Open Access Journals (Sweden)

    Olga Sergeevna Khalyutina

    2017-01-01

    Full Text Available Traditionally, the problem of autonomous navigation is solved by dead reckoning navigation flight parameters (NFP of the aircraft (AC. With increasing requirements to accuracy of definition NFP improved the sensors of the prima- ry navigation information: gyroscopes and accelerometers. the gyroscopes of a new type, the so-called solid-state wave gyroscopes (SSVG are currently developed and put into practice. The work deals with the problem of increasing the accu- racy of measurements of angular velocity of the hemispherical resonator gyroscope (HRG. The reduction in the accuracy characteristics of HRG is caused by the presence of defects in the distribution of mass in the volume of its design. The syn- thesis of control system for optimal damping of the distortion parameters of the standing wave due to the influence of the mass defect resonator is adapted. The research challenge was: to examine and analytically offset the impact of the standing wave (amplitude and frequency parameters defect. Research was performed by mathematical modeling in the environment of SolidWorks Simulation for the case when the characteristics of the sensitive element of the HRG met the technological drawings of a particular type of resonator. The method of the inverse dynamics was chosen for synthesis. The research re- sults are presented in graphs the amplitude-frequency characteristics (AFC of the resonator output signal. Simulation was performed for the cases: the perfect distribution of weight; the presence of the mass defect; the presence of the mass defects are shown using the synthesized control action. Evaluating the effectiveness of the proposed control algorithm is deter- mined by the results of the resonator output signal simulation provided the perfect constructive and its performance in the presence of a mass defect in it. It is assumed that the excitation signals are standing waves in the two cases are identical in both amplitude and frequency. In this

  7. Neutron resonance parameters for 238U

    International Nuclear Information System (INIS)

    Poortmans, F.; Mewissen, L.; Cornelis, E.; Vanpraet, G.; Rohr, G.; Shelley, R.; Veen, T. van der; Weigmann, H.

    1977-01-01

    A series of total, capture and scattering cross section measurements using the neutron time-of-flight facility at the CBNM linear electron accelerator were performed. The neutron widths have been obtained for more than 400 resonances below 4.3 keV and the total capture width for 73 resonances

  8. Re-evaluation of {sup 58}Ni and {sup 60}Ni resonance parameters in the neutron energy range thermal to 800 keV

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H.; Leal, L.C.; Guber, K.H.; Wiarda, D.; Arbanas, G. [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2009-07-01

    The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the experimental data. The systematic uncertainties of the experimental data, estimated from the preliminary analyses of the experimental database, were taken into account in the cross section covariance matrix (CSCM) for total, scattering, and capture cross sections. The diagonal elements of the CSCM were obtained by quadratic combination of the different components of the uncertainties. Because of a lack of experimental information, the energy correlations were not obtained, and a value of 0.5 was arbitrarily taken for all the CSCM nondiagonal elements. The average capture cross-sections are significantly smaller than those calculated form Endf/B7.0

  9. Neutron capture measurements and resonance parameters of dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.G.; Kye, Y.U.; Namkung, W.; Cho, M.H. [Pohang University of Science and Technology, Division of Advanced Nuclear Engineering, Pohang, Gyeongbuk (Korea, Republic of); Kang, Y.R.; Lee, M.W. [Dongnam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of); Kim, G.N. [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Ro, T.I. [Dong-A University, Department of Physics, Busan (Korea, Republic of); Danon, Y.; Williams, D. [Rensselaer Polytechnic Institute, Department of Mechanical, Aerospace, and Nuclear Engineering, Troy, NY (United States); Leinweber, G.; Block, R.C.; Barry, D.P.; Rapp, M.J. [Naval Nuclear Laboratory, Knolls Atomic Power Laboratory, Schenectady, NY (United States)

    2017-10-15

    Neutron capture yields of dysprosium isotopes ({sup 161}Dy, {sup 162}Dy, {sup 163}Dy, and {sup 164}Dy) were measured using the time-of-flight method with a 16 segment sodium iodide multiplicity detector. The measurements were made at the 25m flight station at the Gaerttner LINAC Center at Rensselaer Polytechnic Institute. Resonance parameters were obtained using the multilevel R-matrix Bayesian code SAMMY. The neutron capture data for four enriched dysprosium isotopes and one natural dysprosium sample were sequentially fitted. New resonances not listed in ENDF/B-VII.1 were observed. There were 29 and 17 new resonances from {sup 161}Dy and {sup 163}Dy isotopes, respectively. Six resonances from {sup 161}Dy isotope, two resonances from {sup 163}Dy, and four resonances from {sup 164}Dy were not observed. The capture resonance integrals of each isotope were calculated with the resulting resonance parameters and those of ENDF/B-VII.1 in the energy region from 0.5 eV to 20 MeV and were compared to the capture resonance integrals with the resonance parameters from ENDF/B-VII.1. A resonance integral value of the natural dysprosium calculated with present resonance parameters was 1405 ± 3.5 barn. The value is ∝ 0.3% higher than that obtained with the ENDF/B-VII.1 parameters. The distributions of the present and ENDF/B-VII.1 neutron widths were compared to a Porter-Thomas distribution. Neutron strength functions for {sup 161}Dy and {sup 163}Dy were calculated with the present resonance parameters and both values were in between the values of ''Atlas of Neutron Resonances'' and ENDF/B-VII.1. The present radiation width distributions of {sup 161}Dy and {sup 163}Dy were fitted with the χ{sup 2} distribution by varying the degrees of freedom. (orig.)

  10. Evaluating the Uncertainty in Exchange Parameters Determined from Off-Resonance R1ρ Relaxation Dispersion for Systems in Fast Exchange

    Science.gov (United States)

    Bothe, Jameson R.; Stein, Zachary W.; Al-Hashimi, Hashim M.

    2014-01-01

    Spin relaxation in the rotating frame (R1ρ) is a powerful NMR technique for characterizing fast microsecond timescale exchange processes directed toward short-lived excited states in biomolecules. At the limit of fast exchange, only kex = k1 + k−1 and Φıx = pGpE(Δω)2 can be determined from R1ρ data limiting the ability to characterize the structure and energetics of the excited state conformation. Here, we use simulations to examine the uncertainty with which exchange parameters can be determined for two state systems in intermediate-to-fast exchange using off-resonance R1ρ relaxation dispersion. R1ρ data computed by solving the Bloch-McConnell equations reveals small but significant asymmetry with respect to offset (R1ρ(ΔΩ) ≠ R1ρ(−ΔΩ)), which is a hallmark of slow-to-intermediate exchange, even under conditions of fast exchange for free precession chemical exchange line broadening (kex/Δω > 10). A grid search analysis combined with bootstrap and Monte-Carlo based statistical approaches for estimating uncertainty in exchange parameters reveals that both the sign and magnitude of Δω can be determined at a useful level of uncertainty for systems in fast exchange (kex/Δω exchange parameters. Results from simulations are complemented by analysis of experimental R1ρ data measured in three nucleic acid systems with exchange processes occurring on the slow (kex/Δω = 0.2; pE = ~ 0.7%), fast (kex/Δω = ~10–16; pE = ~13%) and very fast (kex = 39,000 s−1) chemical shift timescales. PMID:24819426

  11. Evaluation of Tumor Angiogenesis Using Dynamic Enhanced Magnetic Resonance Imaging: Comparison of Plasma Vascular Endothelial Growth Factor, Hemodynamic, and Pharmacokinetic Parameters

    International Nuclear Information System (INIS)

    Ikeda, O.; Nishimura, R.; Miyayama, H.; Yasunaga, T.; Ozaki, Y.; Tuji, A.; Yamashita, Y.

    2004-01-01

    Purpose: To assess whether tumor angiogenesis of breast cancers can be predicted on the basis of dynamic magnetic resonance imaging (MRI). Material and Methods: Seventy-one patients with 71 breast cancers underwent Gd-DTPA enhanced dynamic MRI. Two regions of interest measurements were obtained in the periphery and in the center of the breast cancers. Hemodynamic parameters obtained by dynamic MRI included peak time, contrast enhancement ratio (CE ratio), and washout ratio. The triexponential concentration curve of Gd-DTPA was fitted to a theoretical model based on compartmental analysis. The transfer constant (or permeability surface product per unit volume of compartment 'k') was obtained using this method. Tumor angiogenesis was assessed by plasma vascular endothelial growth factor (P-VEGF). Results: The P-VEGF was positive in 28 of 71 tumors (39%). The CE ratio, washout ratio, and k in the periphery in P-VEGF positive breast cancers (mean 178%, 18%, and 1.5x10 -2 (s-1)) were significantly greater (P -2 (s-1)). The peak time in the periphery in P-VEGF positive breast cancers was more marked than for P-VEGF negative breast cancers, but this difference was not significant. Conclusion: The hemodynamic and pharmacokinetic analysis of MRI provides valuable information about angiogenesis of breast cancers

  12. Single-level resonance parameters fit nuclear cross-sections

    Science.gov (United States)

    Drawbaugh, D. W.; Gibson, G.; Miller, M.; Page, S. L.

    1970-01-01

    Least squares analyses of experimental differential cross-section data for the U-235 nucleus have yielded single level Breit-Wigner resonance parameters that fit, simultaneously, three nuclear cross sections of capture, fission, and total.

  13. A method for generating subgroup parameters from resonance tables

    International Nuclear Information System (INIS)

    Devan, K.; Mohanakrishnan, P.

    1993-01-01

    A method for generating subgroup or band parameters from resonance tables is described. A computer code SPART was written using this method. This code generates the subgroup parameters for any number of bands within the specified broad groups at different temperatures by reading the required input data from the binary cross section library in the Cadarache format. The results obtained with SPART code for two bands were compared with that obtained from GROUPIE code and a good agreement was obtained. Results of the generation of subgroup parameters in four bands for sample case of 239 Pu from resonance tables of Cadarache Ver.2 library is also presented. (author). 8 refs., 2 tabs

  14. Recommended formulae and formats for a resonance parameter library

    International Nuclear Information System (INIS)

    James, M.F.

    1968-08-01

    It is proposed that a library of neutron resonance parameters be set up, on punched cards and magnetic tape, which will complement the cross section data in the present U.K. Nuclear Data Library. This report gives parametric formulae for the resolved resonance region, based on:- (i) the Breit-Wigner approximation, (ii) other approximations of R-matrix theory and (iii) the formulae of Adler and Adler. In addition, the statistical distributions of the parameters are given. The final section of the report contains the recommended formats for the parameters of the various formulae. (author)

  15. Nuclear data adjustment methodology utilizing resonance parameter sensitivities and uncertainties

    International Nuclear Information System (INIS)

    Broadhead, B.L.

    1983-01-01

    This work presents the development and demonstration of a Nuclear Data Adjustment Method that allows inclusion of both energy and spatial self-shielding into the adjustment procedure. The resulting adjustments are for the basic parameters (i.e. resonance parameters) in the resonance regions and for the group cross sections elsewhere. The majority of this development effort concerns the production of resonance parameter sensitivity information which allows the linkage between the responses of interest and the basic parameters. The resonance parameter sensitivity methodology developed herein usually provides accurate results when compared to direct recalculations using existng and well-known cross section processing codes. However, it has been shown in several cases that self-shielded cross sections can be very non-linear functions of the basic parameters. For this reason caution must be used in any study which assumes that a linear relatonship exists between a given self-shielded group cross section and its corresponding basic data parameters. The study also has pointed out the need for more approximate techniques which will allow the required sensitivity information to be obtained in a more cost effective manner

  16. Discrete ambiguity resolution and baryon-resonance parameter determination

    International Nuclear Information System (INIS)

    Chew, D.M; Urban, M.

    1978-04-01

    A partial-wave analysis was performed on elastic π + p data between 1400 and 2200 MeV, using principles of analyticity (to select and amalgamate data), causality and unitarity together with Barrelet zeros are the resonating waves between 1500 and 1800 MeV examined in detail, and it is shown how a new resolution of the discrete ambiguity gives, for the S31 and D33 resonances, different parameters than found in an earlier resolution using less accurate information. In either case, mass degeneracy of these resonances is observed in agreement with general considerations regarding smooth zero trajectories. 18 references

  17. Progress on Chinese evaluated nuclear parameter library (CENPL) (II)

    International Nuclear Information System (INIS)

    Su Zhongdi; Ge Zhigang; Zhou Chunmei

    1993-01-01

    CENPL collected, evaluated and compiled nuclear basic constants and model parameters. CENPL-1 contain six sub-libraries, they are: (1) Atomic masses and characteristic constants for nuclear ground states; (2) discrete level schemes and branch ratios of γ decay; (3) level density parameters; (4) giant dipole resonance parameters for γ-ray strength function (5) fission barrier parameter; (6) optical model parameters. Their progresses are introduced

  18. Evaluation of stable tungsten isotopes in the resolved resonance region

    Directory of Open Access Journals (Sweden)

    Schillebeeckx P.

    2013-03-01

    Full Text Available In the last decade benchmark experiments and simulations, together with newly obtained neutron cross section data, have pointed out deficiencies in evaluated data files of W isotopes. The role of W as a fundamental structural material in different nuclear applications fully justifies a new evaluation of 182, 183, 184, 186W neutron resonance parameters. In this regard transmission and capture cross section measurements on natural and enriched tungsten samples were performed at the GELINA facility of the EC-JRC-IRMM. A resonance parameter file used as input in the resonance shape analysis was prepared based on the available literature and adjusted in first instance to transmission data.

  19. Capture cross section and resonance parameters of thulium-169

    International Nuclear Information System (INIS)

    Arbo, J.C.; Felvinci, J.P.; Melkonian, E.; Havens, W.W. Jr.

    1975-01-01

    The previously analyzed energy range for thulium capture resonance parameters is extended from 1 keV to 2 keV. In addition, point and group averaged thulium cross section curves are extended to above 2 keV and 181 Ta impurity levels are discussed. (SDF)

  20. Evaluation and analysis of nuclear resonance data

    International Nuclear Information System (INIS)

    Frohner, F.H.

    2000-01-01

    A probabilistic foundations of data evaluation are reviewed, with special emphasis on parameter estimation based on Bayes' theorem and a quadratic loss function, and on modern methods for the assignment of prior probabilities. The data reduction process leading from raw experimental data to evaluated computer files of nuclear reaction cross sections is outlined, with a discussion of systematic and statistical errors and their propagation and of the generalized least squares formalism including prior information and nonlinear theoretical models. It is explained how common errors induce correlations between data, what consequences they have for uncertainty propagation and sensitivity studies, and how evaluators can construct covariance matrices from the usual error information provided by experimentalists. New techniques for evaluation of inconsistent data are also presented. The general principles are then applied specifically to the analysis and evaluation of neutron resonance data in terms of theoretical models - R-matrix theory (and especially its practically used multi-level Breit-Wigner and Reich-Moore variants) in the resolved region, and resonance-averaged R-matrix theory (Hauser-Feshbach theory with width-fluctuation corrections) in the unresolved region. Complications arise because the measured transmission data, capture and fission yields, self-indication ratios and other observables are not yet the wanted cross sections. These are obtained only by means of parametrisation. The intervening effects - Doppler and resolution broadening, self-shielding, multiple scattering, backgrounds, sample impurities, energy-dependent detector efficiencies, inaccurate reference data etc - are therefore also discussed. (author)

  1. Measurement of the Z Resonance Parameters at LEP

    CERN Document Server

    Barate, R; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Merle, E; Minard, M N; Pietrzyk, B; Alemany, R; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Orteu, S; Pacheco, A; Park, I C; Perlas, J A; Riu, I; Sánchez, F; Colaleo, A; Creanza, D; De Palma, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Bazarko, A; Becker, U; Boix, G; Bird, F; Blucher, E; Bonvicini, G; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Ciulli, V; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Greening, T C; Hagelberg, R; Halley, A W; Hansen, J B; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Knobloch, J; Lazeyras, Pierre; Lehraus, Ivan; Maley, P; Mato, P; May, J; Moutoussi, A; Ranjard, F; Rolandi, Luigi; Schlatter, W D; Schmitt, M; Schneider, O; Spagnolo, P; Tejessy, W; Teubert, F; Tomalin, I R; Tournefier, E; Veenhof, R; Wiedenmann, W; Wright, A E; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Bertelsen, H; Fernley, T; Hansen, F; Hansen, J D; Hansen, J R; Hansen, P H; Lindahl, A; Møllerud, R; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Rougé, A; Rumpf, M; Swynghedauw, M; Tanaka, R; Verderi, M; Videau, H L; Focardi, E; Parrini, G; Zachariadou, K; Cavanaugh, R J; Corden, M; Georgiopoulos, C H; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Picchi, P; Colrain, P; ten Have, I; Hughes, I S; Knowles, I G; Lynch, J G; Morton, W T; Raine, C; Reeves, P; O'Shea, V; Scarr, J M; Smith, K; Thompson, A S; Turnbull, R M; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Marinelli, N; Nash, J; Sciabà, A; Sedgbeer, J K; Thomson, E; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bowdery, C K; Buck, P G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Keemer, N R; Robertson, N A; Sloan, Terence; Snow, S W; Williams, M I; Bauerdick, L A T; Van Gemmeren, P; Giehl, I; Jakobs, K; Kasemann, M; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Schmelling, M; Wachsmuth, H W; Wanke, R; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Carr, J; Coyle, P; Etienne, F; Motsch, F; Payre, P; Rousseau, D; Talby, M; Thulasidas, M; Aleppo, M; Antonelli, M; Ragusa, F; Büscher, V; Dietl, H; Ganis, G; Hüttmann, K; Lütjens, G; Mannert, C; Männer, W; Moser, H G; Schael, S; Settles, Ronald; Seywerd, H C J; Stenzel, H; Wolf, G; Azzurri, P; Boucrot, J; Callot, O; Chen, S; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacholkowska, A; Le Diberder, F R; Lefrançois, J; Lutz, A M; Schune, M H; Veillet, J J; Videau, I; Zerwas, D; Bagliesi, G; Bettarini, S; Boccali, T; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sguazzoni, G; Steinberger, Jack; Tenchini, Roberto; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Cowan, G D; Green, M G; Medcalf, T; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Edwards, M; Haywood, S J; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Cartwright, S L; Combley, F; Lehto, M H; Thompson, L F; Affholderbach, K; Barberio, E; Böhrer, A; Brandt, S; Burkhardt, H; Feigl, E; Grupen, Claus; Hess, J; Lutters, G; Meinhard, H; Minguet-Rodríguez, J A; Mirabito, L; Misiejuk, A; Neugebauer, E; Prange, G; Rivera, F; Saraiva, P; Schäfer, U; Sieler, U; Smolik, L; Stephan, F; Trier, H; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pitis, L; Kim, H; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Cinabro, D; Conway, J S; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; Jin, S; Johnson, R P; Kile, J; McNamara, P A; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Sharma, V; Walsh, A M; Walsh, J; Wear, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    2000-01-01

    The properties of the Z resonance are measured from the analysis of 4.5 million Z decays into fermion pairs collected with the \\Aleph\\ detector at L EP. The data are consistent with lepton universality. The resonance parameters are measured to be $\\MZ=(91.1885 \\pm 0.0031)~\\Gevcc$, $\\GZ= (2.4951 \\pm 0.0043)~\\GeV$, $\\spol=(41.559 \\pm 0.058)$~nb and, combining the three lepton flavours $\\Rl= 20.725\\pm 0.039$. The corresponding number of light neutrino species is $N_{\

  2. Parameter Identification for Nonlinear Circuit Models of Power BAW Resonator

    Directory of Open Access Journals (Sweden)

    CONSTANTINESCU, F.

    2011-02-01

    Full Text Available The large signal operation of the bulk acoustic wave (BAW resonators is characterized by the amplitude-frequency effect and the intermodulation effect. The measurement of these effects, together with that of the small signal frequency characteristic, are used in this paper for the parameter identification of the nonlinear circuit models developed previously by authors. As the resonator has been connected to the measurement bench by wire bonding, the parasitic elements of this connection have been taken into account, being estimated solving some electrical and magnetic field problems.

  3. Parameter dependence of resonant spin torque magnetization reversal

    International Nuclear Information System (INIS)

    Fricke, L.; Serrano-Guisan, S.; Schumacher, H.W.

    2012-01-01

    We numerically study ultra fast resonant spin torque (ST) magnetization reversal in magnetic tunneling junctions (MTJ) driven by current pulses having a direct current (DC) and a resonant alternating current (AC) component. The precessional ST dynamics of the single domain MTJ free layer cell are modeled in the macro spin approximation. The energy efficiency, reversal time, and reversal reliability are investigated under variation of pulse parameters like direct and AC current amplitude, AC frequency and AC phase. We find a range of AC and direct current amplitudes where robust resonant ST reversal is obtained with faster switching time and reduced energy consumption per pulse compared to purely direct current ST reversal. However, for a certain range of AC and direct current amplitudes a strong dependence of the reversal properties on AC frequency and phase is found. Such regions of unreliable reversal must be avoided for ST memory applications.

  4. Parameter dependence of resonant spin torque magnetization reversal

    Science.gov (United States)

    Fricke, L.; Serrano-Guisan, S.; Schumacher, H. W.

    2012-04-01

    We numerically study ultra fast resonant spin torque (ST) magnetization reversal in magnetic tunneling junctions (MTJ) driven by current pulses having a direct current (DC) and a resonant alternating current (AC) component. The precessional ST dynamics of the single domain MTJ free layer cell are modeled in the macro spin approximation. The energy efficiency, reversal time, and reversal reliability are investigated under variation of pulse parameters like direct and AC current amplitude, AC frequency and AC phase. We find a range of AC and direct current amplitudes where robust resonant ST reversal is obtained with faster switching time and reduced energy consumption per pulse compared to purely direct current ST reversal. However, for a certain range of AC and direct current amplitudes a strong dependence of the reversal properties on AC frequency and phase is found. Such regions of unreliable reversal must be avoided for ST memory applications.

  5. Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments

    International Nuclear Information System (INIS)

    MJ Trbovich; DP Barry; RE Slovacck; Y Danon; RC Block; JA Burke; NJ Drindak; G Leinweber; RV Ballad

    2004-01-01

    The focus of this work is to determine resonance parameters for stable hafnium isotopes in the 0.005-200 eV region, with special emphasis on the overlapping 176 Hf and 178 Hf resonances near 8 eV. The large neutron cross section of hafnium, combined with its corrosion resistance and excellent mechanical properties, make it a useful material for controlling nuclear reactions. Experiments measuring neutron capture and transmission were performed at the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) using the time of flight method. 6 Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m. Capture experiments were done using a sixteen section NaI(Tl) multiplicity detector at a flight path length of 25 m. These experiments utilized various thicknesses of metallic and isotopically-enriched liquid samples. The liquid samples were designed to provide information on the 176 Hf and 178 Hf contributions to the 8 eV doublet without saturation. Data analysis was done using the R-matrix Bayesian code SAMMY version M6 beta. SAMMY is able to account for experimental resolution effects for each of the experimental setups at the RPI LINAC, and also can correct for multiple scattering effects in neutron capture yield data. The combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005-200 eV. Resonance integrals were calculated along with errors for each hafnium isotope using the NJOY [1] and INTER [2] codes. The isotopic resonance integrals calculated were significantly different than previously published values; however the calculated elemental hafnium resonance integral changed very little

  6. Resonances and anti-resonances in the material parameters of 2-D dielectric ENG, MNG, and DNG materials

    DEFF Research Database (Denmark)

    Wu, Yunqiu; Arslanagic, Samel

    The resonant/anti-resonant behavior of parameters extracted by the S-parameter method for two-dimensional epsilon-, mu- and double-negative (ENG, MNG, DNG) materials is investigated. The unit cells consist of infinite dielectric cylinders supporting electric dipole, magnetic dipole, or both....... It is shown that the extraction procedure yields one resonant material parameter, and one anti-resonant material parameter in MNG and ENG configurations. However, both parameters display an over-all resonant response in DNG configurations where electric and magnetic dipole modes are excited simultaneously....

  7. Uncertainty of Doppler reactivity worth due to uncertainties of JENDL-3.2 resonance parameters

    Energy Technology Data Exchange (ETDEWEB)

    Zukeran, Atsushi [Hitachi Ltd., Hitachi, Ibaraki (Japan). Power and Industrial System R and D Div.; Hanaki, Hiroshi; Nakagawa, Tuneo; Shibata, Keiichi; Ishikawa, Makoto

    1998-03-01

    Analytical formula of Resonance Self-shielding Factor (f-factor) is derived from the resonance integral (J-function) based on NR approximation and the analytical expression for Doppler reactivity worth ({rho}) is also obtained by using the result. Uncertainties of the f-factor and Doppler reactivity worth are evaluated on the basis of sensitivity coefficients to the resonance parameters. The uncertainty of the Doppler reactivity worth at 487{sup 0}K is about 4 % for the PNC Large Fast Breeder Reactor. (author)

  8. Parameters optimization for magnetic resonance coupling wireless power transmission.

    Science.gov (United States)

    Li, Changsheng; Zhang, He; Jiang, Xiaohua

    2014-01-01

    Taking maximum power transmission and power stable transmission as research objectives, optimal design for the wireless power transmission system based on magnetic resonance coupling is carried out in this paper. Firstly, based on the mutual coupling model, mathematical expressions of optimal coupling coefficients for the maximum power transmission target are deduced. Whereafter, methods of enhancing power transmission stability based on parameters optimal design are investigated. It is found that the sensitivity of the load power to the transmission parameters can be reduced and the power transmission stability can be enhanced by improving the system resonance frequency or coupling coefficient between the driving/pick-up coil and the transmission/receiving coil. Experiment results are well conformed to the theoretical analysis conclusions.

  9. Determination of resonance parameters in QCD by functional analysis methods

    International Nuclear Information System (INIS)

    Ciulli, S.; Geniet, F.; Papadopoulos, N.A.; Schilcher, K.

    1988-01-01

    A mathematically rigorous method based on functional analysis is used to determine resonance parameters of an amplitude from its given asymptotic expression in the space-like region. This method is checked on a model amplitude where both the asymptotic expression and the exact function are known. This method is then applied to the determination of the mass and the width of the ρ-meson from the corresponding space-like asymptotic QCD expression. (orig.)

  10. Nonlinear Parameter Identification of a Resonant Electrostatic MEMS Actuator

    Science.gov (United States)

    Al-Ghamdi, Majed S.; Alneamy, Ayman M.; Park, Sangtak; Li, Beichen; Khater, Mahmoud E.; Abdel-Rahman, Eihab M.; Heppler, Glenn R.; Yavuz, Mustafa

    2017-01-01

    We experimentally investigate the primary superharmonic of order two and subharmonic of order one-half resonances of an electrostatic MEMS actuator under direct excitation. We identify the parameters of a one degree of freedom (1-DOF) generalized Duffing oscillator model representing it. The experiments were conducted in soft vacuum to reduce squeeze-film damping, and the actuator response was measured optically using a laser vibrometer. The predictions of the identified model were found to be in close agreement with the experimental results. We also identified the noise spectral density of process (actuation voltage) and measurement noise. PMID:28505097

  11. Reevaluation and Validation of the 241Pu Resonance Parameters in the Energy Range Thermal to 20 eV

    International Nuclear Information System (INIS)

    Derrien, H.; Leal, L.C.; Courcelle, A.; Santamarina, A.

    2005-01-01

    A new SAMMY analysis of the 241 Pu resonance parameters from thermal to 20 eV is presented. This evaluation takes into account the trends given by integral experiments [post-irradiation experiments performed in French pressurized water reactors (PWRs)]. Compared to the previous evaluations performed by Derrien and de Saussure, the capture cross section increases especially in the 0.26-eV resonance. It is shown that the new resonance parameters proposed in this work improve the prediction of the 242 Pu buildup in a PWR, which was significantly underestimated with the previous evaluations

  12. Progress on Chinese evaluated nuclear parameters library (CENPL). Pt. 3

    International Nuclear Information System (INIS)

    Su Zongdi; Ge Zhigang; Zhou Chunmei

    1994-01-01

    The progress on Chinese evaluated nuclear parameters library (CENPL) is introduced. The setting up work of each sub-library of CENPL has got some new progresses at the past period. These sub-libraries are atomic mass and characteristic constant for nuclear ground state sub-library, discrete level scheme and batch ratio of γ decay sub-library, level density parameter sub-library, giant dipole resonance parameter for γ-ray strength function sub-library and optical model parameter sub-library

  13. Evaluation of temperature dependent neutron resonance integrals

    International Nuclear Information System (INIS)

    Menon, S.V.G.; Sahni, D.C.

    1975-01-01

    The Fourier transform method is extended for evaluating temperature dependent resonance integrals and Doppler coefficients. With the temperature dependent cross-sections, the slowing-down equation is transformed into a Fredholm integral equation of second kind. A method of solution is presented using the familiar Gauss-Hermite quadrature formulae. As a byproduct of the above technique, a fast and accurate method for computing the resonance integral J-function is given. (orig.) [de

  14. Review of methods for level density estimation from resonance parameters

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1983-01-01

    A number of methods are available for statistical analysis of resonance parameter sets, i.e. for estimation of level densities and average widths with account of missing levels. The main categories are (i) methods based on theories of level spacings (orthogonal-ensemble theory, Dyson-Mehta statistics), (ii) methods based on comparison with simulated cross section curves (Monte Carlo simulation, Garrison's autocorrelation method), (iii) methods exploiting the observed neutron width distribution by means of Bayesian or more approximate procedures such as maximum-likelihood, least-squares or moment methods, with various recipes for the treatment of detection thresholds and resolution effects. The present review will concentrate on (iii) with the aim of clarifying the basic mathematical concepts and the relationship between the various techniques. Recent theoretical progress in the treatment of resolution effects, detectability thresholds and p-wave admixture is described. (Auth.)

  15. Parameters Evaluation of PLC Dependability and Safety

    Directory of Open Access Journals (Sweden)

    Juraj Zdansky

    2006-01-01

    Full Text Available This paper is focused on evaluation of dependability and safety parameters of PLC (Programmable Logic Controller. Achievement of requested level of these parameters is an application assumption for using PLC in control of safety critical processes. Evaluation of these parameters can be made on the base of suitable model and it can be influenced by system architecture when necessary.

  16. Extended Gersgorin Theorem-Based Parameter Feasible Domain to Prevent Harmonic Resonance in Power Grid

    Directory of Open Access Journals (Sweden)

    Tao Lin

    2017-10-01

    Full Text Available Harmonic resonance may cause abnormal operation and even damage of power facilities, further threatening normal and safe operation of power systems. For renewable energy generations, controlled loads and parallel reactive power compensating equipment, their operating statuses can vary frequently. Therefore, the parameters of equivalent fundamental and harmonic admittance/impedance of these components exist in uncertainty, which will change the elements and eigenvalues of harmonic network admittance matrix. Consequently, harmonic resonance in power grid is becoming increasingly more complex. Hence, intense research about prevention and suppression of harmonic resonance, particularly the parameter feasible domain (PFD which can keep away from harmonic resonance, are needed. For rapid online evaluation of PFD, a novel method without time-consuming pointwise precise eigenvalue computations is proposed. By analyzing the singularity of harmonic network admittance matrix, the explicit sufficient condition that the matrix elements should meet to prevent harmonic resonance is derived by the extended Gersgorin theorem. Further, via the non-uniqueness of similar transformation matrix (STM, a strategy to determine the appropriate STM is proposed to minimize the conservation of the obtained PFD. Eventually, the availability and advantages in computation efficiency and conservation of the method, are demonstrated through four different scale benchmarks.

  17. On the Methodology to Calculate the Covariance of Estimated Resonance Parameters

    International Nuclear Information System (INIS)

    Becker, B.; Kopecky, S.; Schillebeeckx, P.

    2015-01-01

    Principles to determine resonance parameters and their covariance from experimental data are discussed. Different methods to propagate the covariance of experimental parameters are compared. A full Bayesian statistical analysis reveals that the level to which the initial uncertainty of the experimental parameters propagates, strongly depends on the experimental conditions. For high precision data the initial uncertainties of experimental parameters, like a normalization factor, has almost no impact on the covariance of the parameters in case of thick sample measurements and conventional uncertainty propagation or full Bayesian analysis. The covariances derived from a full Bayesian analysis and least-squares fit are derived under the condition that the model describing the experimental observables is perfect. When the quality of the model can not be verified a more conservative method based on a renormalization of the covariance matrix is recommended to propagate fully the uncertainty of experimental systematic effects. Finally, neutron resonance transmission analysis is proposed as an accurate method to validate evaluated data libraries in the resolved resonance region

  18. n+235U resonance parameters and neutron multiplicities in the energy region below 100 eV

    Directory of Open Access Journals (Sweden)

    Pigni Marco T.

    2017-01-01

    Full Text Available In August 2016, following the recent effort within the Collaborative International Evaluated Library Organization (CIELO pilot project to improve the neutron cross sections of 235U, Oak Ridge National Laboratory (ORNL collaborated with the International Atomic Energy Agency (IAEA to release a resonance parameter evaluation. This evaluation restores the performance of the evaluated cross sections for the thermal- and above-thermal-solution benchmarks on the basis of newly evaluated thermal neutron constants (TNCs and thermal prompt fission neutron spectra (PFNS. Performed with support from the US Nuclear Criticality Safety Program (NCSP in an effort to provide the highest fidelity general purpose nuclear database for nuclear criticality applications, the resonance parameter evaluation was submitted as an ENDF-compatible file to be part of the next release of the ENDF/B-VIII.0 nuclear data library. The resonance parameter evaluation methodology used the Reich-Moore approximation of the R-matrix formalism implemented in the code SAMMY to fit the available time-of-flight (TOF measured data for the thermal induced cross section of n+235U up to 100 eV. While maintaining reasonably good agreement with the experimental data, the validation analysis focused on restoring the benchmark performance for 235U solutions by combining changes to the resonance parameters and to the prompt resonance v̅ below 100 eV.

  19. A mathematical solution for the parameters of three interfering resonances

    Science.gov (United States)

    Han, X.; Shen, C. P.

    2018-04-01

    The multiple-solution problem in determining the parameters of three interfering resonances from a fit to an experimentally measured distribution is considered from a mathematical viewpoint. It is shown that there are four numerical solutions for a fit with three coherent Breit-Wigner functions. Although explicit analytical formulae cannot be derived in this case, we provide some constraint equations between the four solutions. For the cases of nonrelativistic and relativistic Breit-Wigner forms of amplitude functions, a numerical method is provided to derive the other solutions from that already obtained, based on the obtained constraint equations. In real experimental measurements with more complicated amplitude forms similar to Breit-Wigner functions, the same method can be deduced and performed to get numerical solutions. The good agreement between the solutions found using this mathematical method and those directly from the fit verifies the correctness of the constraint equations and mathematical methodology used. Supported by National Natural Science Foundation of China (NSFC) (11575017, 11761141009), the Ministry of Science and Technology of China (2015CB856701) and the CAS Center for Excellence in Particle Physics (CCEPP)

  20. Set up of a method for the adjustment of resonance parameters on integral experiments

    International Nuclear Information System (INIS)

    Blaise, P.

    1996-01-01

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.)

  1. Functional Magnetic Resonance in the Evaluation of Oesophageal Motility Disorders

    OpenAIRE

    Covotta, Francesco; Piretta, Luca; Badiali, Danilo; Laghi, Andrea; Biondi, Tommaso; Corazziari, Enrico S.; Panebianco, Valeria

    2011-01-01

    Functional magnetic resonance imaging (fMRI) has been recently proposed for the evaluation of the esophagus. Our aim is to assess the role of fMRI as a technique to assess morphological and functional parameters of the esophagus in patients with esophageal motor disorders and in healthy controls. Subsequently, we assessed the diagnostic efficiency of fMRI in comparison to videofluoroscopic and manometric findings in the investigation of patients with esophageal motor disorders. Considering...

  2. The thermal neutron absorption cross-sections, resonance integrals and resonance parameters of silicon and its stable isotopes

    International Nuclear Information System (INIS)

    Story, J.S.

    1969-09-01

    The data available up to the end of November 1968 on the thermal neutron absorption cross-sections, resonance absorption integrals, and resonance parameters of silicon and its stable isotopes are collected and discussed. Estimates are given of the mean spacing of the energy levels of the compound nuclei near the neutron binding energy. It is concluded that the thermal neutron absorption cross-section and resonance absorption integral of natural silicon are not well established. The data on these two parameters are somewhat correlated, and three different assessments of the resonance integral are presented which differ over-all by a factor of 230. Many resonances have been detected by charged particle reactions which have not yet been observed in neutron cross-section measurements. One of these resonances of Si 2 8, at E n = 4 ± 5 keV might account for the large resonance integral which is derived, very uncertainly, from integral data. The principal source of the measured resonance integral of Si 3 0 has not yet been located. The thermal neutron absorption cross-section of Si 2 8 appears to result mainly from a negative energy resonance, possibly the resonance at E n = - 59 ± 5 keV detected by the Si 2 8 (d,p) reaction. (author)

  3. Bayesian estimation of multicomponent relaxation parameters in magnetic resonance fingerprinting.

    Science.gov (United States)

    McGivney, Debra; Deshmane, Anagha; Jiang, Yun; Ma, Dan; Badve, Chaitra; Sloan, Andrew; Gulani, Vikas; Griswold, Mark

    2018-07-01

    To estimate multiple components within a single voxel in magnetic resonance fingerprinting when the number and types of tissues comprising the voxel are not known a priori. Multiple tissue components within a single voxel are potentially separable with magnetic resonance fingerprinting as a result of differences in signal evolutions of each component. The Bayesian framework for inverse problems provides a natural and flexible setting for solving this problem when the tissue composition per voxel is unknown. Assuming that only a few entries from the dictionary contribute to a mixed signal, sparsity-promoting priors can be placed upon the solution. An iterative algorithm is applied to compute the maximum a posteriori estimator of the posterior probability density to determine the magnetic resonance fingerprinting dictionary entries that contribute most significantly to mixed or pure voxels. Simulation results show that the algorithm is robust in finding the component tissues of mixed voxels. Preliminary in vivo data confirm this result, and show good agreement in voxels containing pure tissue. The Bayesian framework and algorithm shown provide accurate solutions for the partial-volume problem in magnetic resonance fingerprinting. The flexibility of the method will allow further study into different priors and hyperpriors that can be applied in the model. Magn Reson Med 80:159-170, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  5. Review of the different methods to derive average spacing from resolved resonance parameters sets

    International Nuclear Information System (INIS)

    Fort, E.; Derrien, H.; Lafond, D.

    1979-12-01

    The average spacing of resonances is an important parameter for statistical model calculations, especially concerning non fissile nuclei. The different methods to derive this average value from resonance parameters sets have been reviewed and analyzed in order to tentatively detect their respective weaknesses and propose recommendations. Possible improvements are suggested

  6. Auxiliary programs for resonance parameter storage and retrieval system REPSTOR. XTOREP, ETOREP, REPTOINP, REPRENUM, REPIMRG, TREP, PASSIGN, JCONV

    International Nuclear Information System (INIS)

    Nakagawa, Tsuneo; Kikuchi, Yasuyuki; Fukahori, Tokio

    1999-06-01

    This report describes functions and usage of eight auxiliary computer programs for REPSTOR that is a computer program for collecting the resonance parameters and evaluating them. The programs are XTOREP to convert the experimental data in EXFOR to the REPSTOR input data, ETOREP to convert the data in ENDF format to the REPSTOR input data, REPTOINP to change the data in a REPSTOR file into the REPSTOR input format, REPRENUM to renumber the level number of resonance levels, REPIMRG to merge the XTOREP output data sets, TREP to calculate mean values of resonance parameters, widths of individual resonances, etc., PASSIGN to assign orbital angular momentum by using Bayse theorem, and JCONV to assign total spin. (author)

  7. Evaluation of Haematological and Biochemical Parameters of ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Evaluation of Haematological and Biochemical Parameters of Juvenile Oreochromis niloticus after Exposure to Water Soluble Fractions of ... niloticus were evaluated. After a preliminary determination of the 96 h-LC50 of ... evaporation, dissolution, emulsion, photolysis and biodegradation which generate a water soluble.

  8. Statistical analysis of parameters of the uranium -238 resonances

    International Nuclear Information System (INIS)

    Nikolaev, M.N.; Abagyan, L.P.

    1976-01-01

    It has been shown that the distribution for 238 U p - levels can be in agreement with the theoretical one (Porter - Thomas distribution) only if the significant lack of p - levels in the experiments would be supposed. That means that density of 238 U levels with spin 1/2 is parity dependent, and therefore the whole number of p - resonances is 4.8 (instead of 3) times greater than the number of s - resonances in the same energy internal. With the assumption about spin dependence of strength function it is impossible to agree the experimental distribution with the theoretical one

  9. Stochastic resonance in the presence of slowly varying control parameters

    International Nuclear Information System (INIS)

    Nicolis, C; Nicolis, G

    2005-01-01

    The kinetics of transitions between states in a noisy system is studied in the simultaneous presence of a periodic forcing and a ramp. It is shown that the interaction between stochastic resonance and the action of the ramp may give rise to a new method for the control of the transition rates

  10. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  11. Estimation of uncertainties in resonance parameters of {sup 56}Fe, {sup 239}Pu, {sup 240}Pu and {sup 238}U

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Tsuneo; Shibata, Keiichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-05-01

    Uncertainties have been estimated for the resonance parameters of {sup 56}Fe, {sup 239}Pu, {sup 240}Pu and {sup 238}U contained in JENDL-3.2. Errors of the parameters were determined from the measurements which the evaluation was based on. The estimated errors have been compiled in the MF32 of the ENDF format. The numerical results are given in tables. (author)

  12. Numerical analysis of the resonance mechanism of the lumped parameter system model for acoustic mine detection

    International Nuclear Information System (INIS)

    Wang Chi; Zhou Yu-Qiu; Shen Gao-Wei; Wu Wen-Wen; Ding Wei

    2013-01-01

    The method of numerical analysis is employed to study the resonance mechanism of the lumped parameter system model for acoustic mine detection. Based on the basic principle of the acoustic resonance technique for mine detection and the characteristics of low-frequency acoustics, the ''soil-mine'' system could be equivalent to a damping ''mass-spring'' resonance model with a lumped parameter analysis method. The dynamic simulation software, Adams, is adopted to analyze the lumped parameter system model numerically. The simulated resonance frequency and anti-resonance frequency are 151 Hz and 512 Hz respectively, basically in agreement with the published resonance frequency of 155 Hz and anti-resonance frequency of 513 Hz, which were measured in the experiment. Therefore, the technique of numerical simulation is validated to have the potential for analyzing the acoustic mine detection model quantitatively. The influences of the soil and mine parameters on the resonance characteristics of the soil—mine system could be investigated by changing the parameter setup in a flexible manner. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Determination of the decay parameters of resonant states

    International Nuclear Information System (INIS)

    Tsoupas, N.

    1975-01-01

    The partial decay proton widths and the relative phases of six of the resonances in 29 P from excitation energies 5.7 to 7.1 MeV were determined. For this determination the angular distributions of protons scattered inelastically from the first 2 + excited state in 28 Si have been measured at 88 energies between E/sub p/ = 3.0 to 5.2 MeV. The coefficients describing the angular distributions were extracted from the experimental data and plotted as a function of C.M. bombarding energy over the resonance region. In addition triple angular correlations in the spin-flip geometry of the inelastically scattered protons from the 2 + first excited state of 28 Si with the γ-rays resulted from the de-excitation of 28 Si to its ground state were performed over the energy region E/sub p/ = 3.0 to 4.7 MeV. The coefficients describing these triple angular correlations were extracted and plotted versus C.M. bombarding energy. To aid in the analysis the experimental data of another triple angular correlation in the Goldfarb-Seyler geometry between the two radiations as in the spin flip angular correlation were used. Further analysis of the experimental data for the extraction of the partial decay widths and phases proceeded by calculating the theoretical expressions of the coefficients versus energy, using a Breit-Wigner formalism including interference between the resonances. The calculated theoretical coefficients were compared with the experimental ones through an on-line interactive program which permitted visual comparisons of the theoretically calculated coefficients to the experimental coefficients. The partial decay proton widths and the relative phases for six of the resonances will be presented in this dissertation

  14. A Short History of ENDF/B Unresolved Resonance Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, Dermott E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-10-31

    This paper is designed to address two topics relating to ENDF/B data in the unresolved resonance region, Part 1: For years code users have pointed out and complained that various ENDF data processing codes, in particular PREPRO and NJOY, produce different answers from one another for the cross sections in unresolved resonance region. First I assure code users that NJOY has now been updated to agree with PREPRO, so that this problem has now been solved. Part 2: Next, this paper documents why we saw these differences; the emphasis here is on explaining what my own codes do, but I will also try to briefly outline what other codes do, so the reader can understand why we were producing different answers. The first topic should be of general interest to all readers, particularly users of our codes, whereas the second topic will be of more limited interest only to those readers who are interested in the details of our calculations in the unresolved resonance region. Now that our PREPRO and NJOY results agree we consider this problem solved and no further action is necessary.

  15. Evaluation of neutron nuclear data for 233U in thermal and resonance regions

    International Nuclear Information System (INIS)

    Kikuchi, Yasuyuki

    1981-02-01

    The thermal and resonance cross sections of 233 U were evaluated for JENDL-2. The cross sections below 1 eV are given as point-wise data and were evaluated by the use of the measured fission and capture cross sections. The resolved resonance parameters are derived up to 100 eV. The parameters were obtained by using NDES so as to reproduce the measured total and fission cross sections. The cross sections from 100 eV to 30 keV are represented by the unresolved resonance parameters. The fission and capture resonance integrals calculated from these parameters are 771 and 138 barns, respectively, which agree with the measured data within the quoted errors. (author)

  16. Aperiodic signals processing via parameter-tuning stochastic resonance in a photorefractive ring cavity

    Directory of Open Access Journals (Sweden)

    Xuefeng Li

    2014-04-01

    Full Text Available Based on solving numerically the generalized nonlinear Langevin equation describing the nonlinear dynamics of stochastic resonance by Fourth-order Runge-Kutta method, an aperiodic stochastic resonance based on an optical bistable system is numerically investigated. The numerical results show that a parameter-tuning stochastic resonance system can be realized by choosing the appropriate optical bistable parameters, which performs well in reconstructing aperiodic signals from a very high level of noise background. The influences of optical bistable parameters on the stochastic resonance effect are numerically analyzed via cross-correlation, and a maximum cross-correlation gain of 8 is obtained by optimizing optical bistable parameters. This provides a prospective method for reconstructing noise-hidden weak signals in all-optical signal processing systems.

  17. Statistical inference of level densities from resolved resonance parameters

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1983-08-01

    Level densities are most directly obtained by counting the resonances observed in the resolved resonance range. Even in the measurements, however, weak levels are invariably missed so that one has to estimate their number and add it to the raw count. The main categories of missinglevel estimators are discussed in the present review, viz. (I) ladder methods including those based on the theory of Hamiltonian matrix ensembles (Dyson-Mehta statistics), (II) methods based on comparison with artificial cross section curves (Monte Carlo simulation, Garrison's autocorrelation method), (III) methods exploiting the observed neutron width distribution by means of Bayesian or more approximate procedures such as maximum-likelihood, least-squares or moment methods, with various recipes for the treatment of detection thresholds and resolution effects. The language of mathematical statistics is employed to clarify the basis of, and the relationship between, the various techniques. Recent progress in the treatment of resolution effects, detection thresholds and p-wave admixture is described. (orig.) [de

  18. New evaluation parameter for wearable thermoelectric generators

    Science.gov (United States)

    Wijethunge, Dimuthu; Kim, Woochul

    2018-04-01

    Wearable devices constitute a key application area for thermoelectric devices. However, owing to new constraints in wearable applications, a few conventional device optimization techniques are not appropriate and material evaluation parameters, such as figure of merit (zT) and power factor (PF), tend to be inadequate. We illustrated the incompleteness of zT and PF by performing simulations and considering different thermoelectric materials. The results indicate a weak correlation between device performance and zT and PF. In this study, we propose a new evaluation parameter, zTwearable, which is better suited for wearable applications compared to conventional zT. Owing to size restrictions, gap filler based device optimization is extremely critical in wearable devices. With respect to the occasions in which gap fillers are used, expressions for power, effective thermal conductivity (keff), and optimum load electrical ratio (mopt) are derived. According to the new parameters, the thermal conductivity of the material has become much more critical now. The proposed new evaluation parameter, namely, zTwearable, is extremely useful in the selection of an appropriate thermoelectric material among various candidates prior to the commencement of the actual design process.

  19. Characteristics of Schumann Resonance Parameters at Kuju Station

    Directory of Open Access Journals (Sweden)

    Ikeda Akihiro

    2017-01-01

    Full Text Available The ground magnetic field variation in the extremely low frequency (ELF range has been measured by an induction magnetometer at Kuju, Japan (KUJ; M.Lat. = 23.4 degrees, M. Lon. = 201.0 degrees since 2003. The first mode of the Schumann resonance (SR around 8 Hz can be seen at KUJ. The SR in H (horizontal northward component shows maximum peaks around 08 UT and 15 UT. In the case of D (horizontal eastward component, the SR shows its maximum peak around 08 UT. These peaks are coincident with the enhancement of lightning activity in Africa and Asia. Thus, we found the influence of the lightning activity on the observed SR at KUJ.

  20. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1980-01-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (author)

  1. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1978-07-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (orig.) [de

  2. Electron paramagnetic resonance parameters and local structure for ...

    Indian Academy of Sciences (India)

    HUA-MING ZHANG. 1. , GUANG-DUO LU. 1 ... the above ZFSs, the local structure information for the impurity Gd. 3+ is obtained, i.e., .... parameters, extended X-ray absorption fine-structure (EXAFS) measurements and crystal-field spectrum ...

  3. The diabetic foot: Magnetic resonance imaging evaluation

    International Nuclear Information System (INIS)

    Beltran, J.; Campanini, D.S.; Knight, C.; McCalla, M.

    1990-01-01

    Fourteen diabetic patients with suspected foot infection and/or neuropathic joint (Charcot Joint) were evaluated with magnetic resonance imaging (MRI) in an attempt to assess the extent of the infection and also to distinguish infection from the changes seen with neuroarthropathy. The majority of patients with infection had more than one site of involvement and the following diagnoses were made by MRI evaluation: Osteomyelitis (n=8), abscess (n=7), neuropathic joint (n=5), septic arthritis (n=4), and tenosynovitis (n=4). Clinical or surgical/pathological confirmation of the MRI diagnoses was obtained in all but nine sites of infection or cases of neuropathic joint. If the two diagnostic categories of septic arthritis and tenosynovitis are excluded, all but four of the MRI diagnoses were confirmed. A distinctive pattern for neuroarthropathy was identified in five cases, consisting of low signal intensity on T1- and T2-weighted images within the bone marrow space adjacent to the involved joint. We conclude that MRI is a valuable adjunct in the evaluation of the diabetic foot, and that it provides accurate information regarding the presence and extent of infection in this subset of patients. MRI has proven particularly helpful in differentiating neuroarthropathy from osteomyelitis. (orig.)

  4. A method for generating subgroup parameters from resonance tables and the SPART code

    International Nuclear Information System (INIS)

    Devan, K.; Mohanakrishnan, P.

    1995-01-01

    A method for generating subgroup or band parameters from resonance tables is described. A computer code SPART was written using this method. This code generates the subgroup parameters for any number of bands within the specified broad groups at different temperatures by reading the required input data from the binary cross section library in the Cadarache format. The results obtained with SPART code for two bands were compared with that obtained from GROUPIE code and a good agreement was obtained. Results of the generation of subgroup parameters in four bands for sample case of 239 Pu from resonance tables of Cadarache Ver.2 library is also presented. 6 refs, 2 tabs

  5. Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Samarium

    International Nuclear Information System (INIS)

    Leinweber, G.; Burke, J.A.; Knox, H.D.; Drindak, N.J.; Mesh, D.W.; Haines, W.T.; Ballad, R.V.; Block, R.C.; Slovacek, R.E.; Werner, C.J.; Trbovich, M.J.; Barry, D.P.; Sato, T.

    2001-01-01

    The purpose of the present work is to accurately measure the neutron cross sections of samarium. The most significant isotope is 149 Sm, which has a large neutron absorption cross section at thermal energies and is a 235 U fission product with a 1% yield. Its cross sections are thus of concern to reactor neutronics. Neutron capture and transmission measurements were performed by the time-of-flight technique at the Rensselaer Polytechnic institute (RPI) LINAC facility using metallic and liquid Sm samples. The capture measurements were made at the 25 meter flight station with a multiplicity-type capture detector, and the transmission total cross-section measurements were performed at 15- and 25-meter flight stations with 6 Li glass scintillation detectors. Resonance parameters were determined by a combined analysis of six experiments (three capture and three transmission) using the multi-level R-matrix Bayesian code SAMMY version M2. The significant features of this work are as follows. Dilute samples of samarium nitrate in deuterated water (D 2 O) were prepared to measure the strong resonances at 0.1 and 8 eV without saturation. Disk-shaped spectroscopic quartz cells were obtained with parallel inner surfaces to provide a uniform thickness of solution. The diluent feature of the SAMMY program was used to analyze these data. The SAMMY program also includes multiple scattering corrections to capture yield data and resolution functions specific to the RPI facility. Resonance parameters for all stable isotopes of samarium were deduced for all resonances up to 30 eV. Thermal capture cross-section and capture resonance integral calculations were made using the resultant resonance parameters and were compared to results obtained using resonance parameters from ENDF/B-VI updated through release 3. Extending the definition of the capture resonance integral to include the strong 0.1 eV resonance in 149 Sm, present measurements agree within estimated uncertainties with En

  6. 12 O resonant structure evaluated by two-proton emission process

    International Nuclear Information System (INIS)

    Leite, T.N.; Teruya, N.; Goncalves, M.

    2009-06-01

    The characteristics of 12 O resonant ground state are investigated through the analysis of the experimental data for the two-proton decay process. The sequential and simultaneous two-proton emission decay modes have been considered in a statistical calculation of the decay energy distribution. The resonant structures of 11 N have been employed as intermediate states for the sequential mode, having their parameters determined by considering the structure of single particle resonance in quantum scattering problem. The width of 12 O resonant ground state has been extracted from a best fit to the experimental data. The contributions from the different channels to the decay energy distribution have been evaluated, and width and peak location parameters of 12 O resonant ground state are compared with results of other works for the sequential and simultaneous two-proton decay modes. (author)

  7. 12O resonant structure evaluated by the two-proton emission process

    International Nuclear Information System (INIS)

    Leite, T. N.; Teruya, N.; Dimarco, A.; Duarte, S. B.; Tavares, O. A. P.; Goncalves, M.

    2009-01-01

    The characteristics of the 12 O resonant ground state are investigated through the analysis of the experimental data for the two-proton decay process. The sequential and simultaneous two-proton emission decay modes have been considered in a statistical calculation of the decay energy distribution. The resonant structures of 11 N have been employed as intermediate states for the sequential mode, having their parameters determined by considering the structure of single particle resonance in quantum scattering problem. The width of the 12 O resonant ground state has been extracted from a best fit to the experimental data. The contributions from the different channels to the decay energy distribution have been evaluated, and width and peak location parameters of the 12 O resonant ground state are compared with results of other works for the sequential and simultaneous two-proton decay modes.

  8. {sup 12} O resonant structure evaluated by two-proton emission process

    Energy Technology Data Exchange (ETDEWEB)

    Leite, T.N. [Fundacao Universidade Federal do Vale do Sao Francisco (UNIVASF), Juazeiro, BA (Brazil); Teruya, N. [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil). Dept. de Fisica; Dimarco, A. [Universidade Estadual de Santa Cruz (UESC), Ilheus, BA (Brazil). Dept. de Ciencias Exatas e Tecnologicas; Duarte, S.B.; Tavares, O.A.P. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Goncalves, M. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2009-06-15

    The characteristics of {sup 12}O resonant ground state are investigated through the analysis of the experimental data for the two-proton decay process. The sequential and simultaneous two-proton emission decay modes have been considered in a statistical calculation of the decay energy distribution. The resonant structures of {sup 11} N have been employed as intermediate states for the sequential mode, having their parameters determined by considering the structure of single particle resonance in quantum scattering problem. The width of {sup 12}O resonant ground state has been extracted from a best fit to the experimental data. The contributions from the different channels to the decay energy distribution have been evaluated, and width and peak location parameters of {sup 12}O resonant ground state are compared with results of other works for the sequential and simultaneous two-proton decay modes. (author)

  9. Determination of Intermediate Resonance Parameter with RMET21 for nTRACER

    International Nuclear Information System (INIS)

    Sohail, Muhammad; Kim, Myung Hyun

    2012-01-01

    Ray Tracing based code nTRACER is being developed in Seoul National University that has the capability of 3-dimensional whole core neutron transport calculation. As a part of development of multi-group neutron cross section library for nTRACER, the current work is intended to accurately determine intermediate resonance parameters. Beside the systematic calculation of subgroup parameters for resonance self shielding calculation, intermediate resonance parameters itself can be as important as the multi-group neutron cross section in the library and its overall accuracy. In this paper lambda factors were computed using RMET21 from ENDF/B-VII.1 for nTRACER to investigate its dependence on temperature and background cross section and replaced with lambda factors from HELIOS multi-group library. The procedure used for determining the intermediate resonance parameter for the isotope under study is introduced in the next section. Oxygen being one of the primary nuclide in PWR fuel has been selected for intermediate resonance parameters calculation

  10. Isoscalar giant resonances and Landau parameters with density-dependent effective interactions

    International Nuclear Information System (INIS)

    Kohno, Michio; Ando, Kazuhiko

    1979-01-01

    Discussion is given on the relations between the Landau parameters and the isoscalar giant (quadrupole- and monopole-) resonance energies by using general density-dependent interactions. In the limit of infinite nuclear matter, the isoscalar giant quadrupole energy is shown to depend not only on the effective mass but also on the Landau parameter F 2 . Collective energies of the isoscalar giant resonances are calculated for 16 O and 40 Ca with four different effective interactions, G-0, B1, SII and SV, by using the scaling- and constrained Hartree-Fock-methods. It is shown that the dependence of the collective energies on the effective interactions is essentially determined by the Landau parameters. The G-0 force is found to be most successful in reproducing the giant resonance energies. Validity of the RPA-moment theorems is examined for the case of local density-dependent interactions. (author)

  11. Chronic liver disease: evaluation by magnetic resonance

    International Nuclear Information System (INIS)

    Stark, D.D.; Goldberg, H.I.; Moss, A.A.; Bass, N.M.

    1984-01-01

    Magnetic resonance (MR) imaging distinguished hepatitis from fatty liver and cirrhosis in a woman with a history of alcohol abuse. Anatomic and physiologic manifestations of portal hypertension were also demonstrated by MR

  12. Evaluation of Cm-247 neutron cross sections in the resonance region

    International Nuclear Information System (INIS)

    Martinelli, T.; Menapace, E.; Motta, M.; Vaccari, M.

    1980-01-01

    The neutron cross sections of Cm-247 are evaluated in the resonance (resolved and unresolved) region up to 10 keV. Average resonance parameters (i.e. spacing D, fission and radiative widths, neutron strength functions) are determined for unresolved region calculations. Moreover for a better comparison with the experimental data, fission cross section is calculated up to 10 MeV. In addition, the average number of neutrons emitted per fission as a function of energy is estimated

  13. Resonance analysis and evaluation of the 235U neutron induced cross sections

    International Nuclear Information System (INIS)

    Leal, L.C.

    1990-06-01

    Neutron cross sections of fissile nuclei are of considerable interest for the understanding of parameters such as resonance absorption, resonance escape probability, resonance self-shielding,and the dependence of the reactivity on temperature. In the present study, new techniques for the evaluation of the 235 U neutron cross sections are described. The Reich-Moore formalism of the Bayesian computer code SAMMY was used to perform consistent R-matrix multilevel analyses of the selected neutron cross-section data. The Δ 3 -statistics of Dyson and Mehta, along with high-resolution data and the spin-separated fission cross-section data, have provided the possibility of developing a new methodology for the analysis and evaluation of neutron-nucleus cross sections. The results of the analysis consists of a set of resonance parameters which describe the 235 U neutron cross sections up to 500 eV. The set of resonance parameters obtained through a R-matrix analysis are expected to satisfy statistical properties which lead to information on the nuclear structure. The resonance parameters were tested and showed good agreement with the theory. It is expected that the parametrization of the 235 U neutron cross sections obtained in this dissertation represents the current state of art in data as well as in theory and, therefore, can be of direct use in reactor calculations. 44 refs., 21 figs., 8 tabs

  14. Importance of resonance parameters of fertile nuclei and of 239Pu isotope for fast power reactors

    International Nuclear Information System (INIS)

    Barre, J.Y.; Khairallah, A.

    1975-01-01

    The importance of resonance parameters of fertile nuclei and of 239 Pu isotope for fast power reactors will be restricted, in this presentation, to mixed oxide-uranium-plutonium fuelled sodium-cooled and uranium-oxide-sodium reflected fast reactors. The power range lies between 200 and 2000 MWe. Among the topics of this specialist meeting, the isotopes to be considered are, primarly 239 Pu then 238 U and 240 Pu. Resonance parameters are mainly used in fast power reactor calculations through the well-known concept of self shielding factors. After a short description of the determination and the use of these self-shielding factors, their sensitivities to resonance parameters are characterized from some specific examples: those sensitivities are small. Then, the main design parameters sensitive to the amplitude of self-shielding factors are considered: critical enrichment, global breeding gain. The relative importance of isotope, reaction rate and energy range are mentionned. In a third part, the Doppler effect, sensitive to the temperature variation of self-shielding factors, is considered in the same way. Finally, it is concluded that the present knowledge of resonance parameters for 238 U, 239 Pu and 240 Pu is sufficient for fast power reactors from a designer point of view [fr

  15. Neutron total cross-sections and resonance parameters of Mo and Ta

    Indian Academy of Sciences (India)

    Linear accelerator; total cross-sections; resonance parameters; SAMMY code. ... Centre for Atomic Research, Kalpakkam 603 102, India; Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784, Korea; Department of Physics, Kyungpook National University, Daegu 702-701, Korea ...

  16. Nuclear statistics of dysprosium resonance parameters in the energy range 10 - 1000 eV

    International Nuclear Information System (INIS)

    Shin, S. G.; Kye, Y. U.; Cho, M. H.; Kim, G. N.; Namkung, W.; Lee, M. W.; Kang, Y. R.; Roe, T. I.

    2016-01-01

    A resonance parameter analysis is often performed in the Resolved Resonance Region (RRR) in order to estimate the average level spacing, distribution of the reduced widths and so on. Neutron Capture experiments on dysprosium isotopes were performed at the electron linear accelerator (LINAC) facility of the Rensselear Polytechnic Institute (RPI) in the neutron energy region from 10 eV to 1 keV. The following nuclear statistics of the resonance parameters will be discussed in this paper. The D 0 for 161 Dy and 163 Dy were judged to be constant up to 120.6 and 163.9 eV, respectively. It was assumed that the D 0 of 162 Dy and 164 Dy is constant up to 1000 eV because they have few resonances. The results were compared with the values from Reference 11 as shown in Figure 1. Statistical distributions of reduced neutron were investigated for the three isotopes in the region from 0 to 1000 eV; 161 Dy, 162 Dy, and 163 Dy, but not for 164 Dy because of a few number of resonances. The reduced neutron widths Γ n 0 were divided by the unweighted average reduced neutron width < Γ n 0 > for each isotope. A cumulative distribution of these unitless ratios is compared with the integral of the Porter-Thomas distribution (χ 2 distribution with one degree of freedom). The results agree reasonably with the Porter Thomas distributions.

  17. Parameter allocation of parallel array bistable stochastic resonance and its application in communication systems

    International Nuclear Information System (INIS)

    Liu Jian; Zhai Qi-Qing; Wang You-Guo; Liu Jin

    2016-01-01

    In this paper, we propose a parameter allocation scheme in a parallel array bistable stochastic resonance-based communication system (P-BSR-CS) to improve the performance of weak binary pulse amplitude modulated (BPAM) signal transmissions. The optimal parameter allocation policy of the P-BSR-CS is provided to minimize the bit error rate (BER) and maximize the channel capacity (CC) under the adiabatic approximation condition. On this basis, we further derive the best parameter selection theorem in realistic communication scenarios via variable transformation. Specifically, the P-BSR structure design not only brings the robustness of parameter selection optimization, where the optimal parameter pair is not fixed but variable in quite a wide range, but also produces outstanding system performance. Theoretical analysis and simulation results indicate that in the P-BSR-CS the proposed parameter allocation scheme yields considerable performance improvement, particularly in very low signal-to-noise ratio (SNR) environments. (paper)

  18. A benchmark test of computer codes for calculating average resonance parameters

    International Nuclear Information System (INIS)

    Ribon, P.; Thompson, A.

    1983-01-01

    A set of resonance parameters has been generated from known, but secret, average values; the parameters have then been adjusted to mimic experimental data by including the effects of Doppler broadening, resolution broadening and statistical fluctuations. Average parameters calculated from the dataset by various computer codes are compared with each other, and also with the true values. The benchmark test is fully described in the report NEANDC160-U (NEA Data Bank Newsletter No. 27 July 1982); the present paper is a summary of this document. (Auth.)

  19. Average values of 235U resonance parameters up to 500 eV

    International Nuclear Information System (INIS)

    Leal, L.C.

    1991-01-01

    An R-matrix analysis of 235 U neutron cross sections was recently completed. The analysis was performed with the multilevel-multichannel Reich-Moore computer code SAMMY and extended the resolved resonance region up to 500 eV. Several high resolution measurements namely, transmission, fission and capture data as well as spin separated fission data were analyzed in a consistent manner and a very accurate parametrization up to 500 eV of these data were obtained. The aim of this paper is to present the results of average values of the resonance parameters. 9 refs., 1 tab

  20. Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium

    International Nuclear Information System (INIS)

    NJ Drindak; JA Burke; G Leinweber; JA Helm; JG Hoole; RC Block; Y Danon; RE Slovacek; BE Moretti; CJ Werner; ME Overberg; SA Kolda; MJ Trbovich; DP Barry

    2005-01-01

    Epithermal neutron capture and transmission measurements were performed using the time-of-flight method at the RPI linac using metallic Nb samples. The capture measurements were made at the 25-meter flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-meter flight station with a Li-6 glass scintillation detector. Resonance parameters were determined for all resonances up to 500eV with a combined analysis of capture and transmission data using the multi-level R-matrix Bayesian code SAMMY. The present results are compared to those presented in ENDF/B-VI, updated through Release 3

  1. Evaluation of Mechanical Parameters of Pellets

    Directory of Open Access Journals (Sweden)

    Ľubomír Kubík

    2016-01-01

    Full Text Available The paper dealt with the evaluation of mechanical properties of the cylinder wheat straw, rapeseed straw and 50/50 % mixed wheat and rapeseed straw pellet samples. The pellets were made by the granulating machine MGL 200 (Kovonovak. The compressive loading curves of dependencies of stress on strain were realised by the test stand Andilog Stentor 1000 (Andilog Technologies, Vitrolles, France. Certain mechanical parameters were determined, namely the initial force (force at 10 % of compress strain, force in maximum of loading curve, strain in maximum of loading curve, initial stress (stress at 10 % of compression strain, stress in maximum of loading curve and modulus of elasticity. Mean value of the initial force was maximal for mixed straw pellet samples 52.49 N. Mean values of the initial force of the wheat straw samples and the rapeseed straw samples were smaller and almost identical 43.58 N and 43.12 N. Mean values of the initial stress of loading curve, of the wheat straw samples reached 1.46 MPa, the rapeseed straw samples reached value 1.40 MPa and the mixed straw samples reached value 1.63 MPa. Mean value of the force in maximum of loading curve was also maximal for mixed straw pellet samples 213.26 N. Mean values of the force in maximum of loading curve of the wheat straw samples reached 178.11 N. The rapeseed straw samples reached value 95.95 N and the mixed straw samples reached value 213.26 N. Mean values of the stress in maximum of loading curve, of the wheat straw samples reached 5.93 MPa, the rapeseed straw samples reached value 3.11 MPa and the mixed straw samples reached value 7.10 MPa Mean values of the modulus of elasticity, of the wheat straw samples reached 18.27 MPa, the rapeseed straw samples reached value 13.08 MPa and the mixed straw samples reached value 14.97 MPa. Significant correlations of the mechanical parameters pellet samples were observed among initial force and initial stress and modulus of elasticity

  2. Resonance proton scattering use for the beam parameters control of the electrostatic accelerator

    Directory of Open Access Journals (Sweden)

    V. I. Soroka

    2013-12-01

    Full Text Available The paper discusses peculiarities of the resonance proton scattering use for the beam parameters control of the electrostatic accelerators. The expediency of the use has been confirmed by experiment. Peculiarities are caused because elastic resonance scattering through the stage of compound nucleus is always accompanied by potential and Coulomb scattering. These three components interfere and for that reason the resonance form de-pends on a scattering angle and total angular moment of a compound nucleus level. However, possessing neces-sary information in the given field of nuclear spectroscopy enables the selection of resonance with the character-istics suitable for the calibration purpose. Considerable increase of the scattering cross section in the resonance region saves the time and simplifies the experiment technical maintenance. The experiments were performed at the 10 MeV tandem accelerator of the Institute for Nuclear Research, National Academy of Sciences of Ukraine, Kyiv, after its modernization. Silicon and oxygen were used as the targets. Silicon targets were of two types of thickness: 1 the target of complete absorption, 2 the target with the thickness in which the loss of protons ener-gy exceeded the width of the selected resonance. The elastic and non elastic scattering from silicon were used in region of the 3,100 MeV proton energy resonance. Oxygen target, as component of the surface oxidizing layer on beryllium had the thickness which in terms of the loss of proton energy was less than the width of the selected elastic narrow resonance at 3,470 MeV proton energy. As result of the measurement the corrections concerning the energy scale of the accelerator and protons energy spread in the beam were proposed.

  3. Magnetic resonance imaging textural evaluation of posterior cranial fossa tumors in childhood

    International Nuclear Information System (INIS)

    Santos, Joelson Alves dos; Costa, Maria Olivia Rodrigues da; Otaduy, Maria Concepcion Garcia; Lacerda, Maria Teresa Carvalho de; Leite, Claudia da Costa; Matsushita, Hamilton

    2004-01-01

    Objective: To distinguish healthy from pathological tissues in pediatric patients with posterior cranial fossa tumors using calculated textural parameters from magnetic resonance images. Materials And Methods: We evaluated 14 pediatric patients with posterior cranial fossa tumors using the software MaZda to define the texture parameters in selected regions of interest representing healthy and pathological tissues based on T2-weighted magnetic resonance images. Results: There was a statistically significant difference between normal and tumoral tissues as well as between supposedly normal tissues adjacent and distant from the tumoral lesion. Conclusion: Magnetic resonance textural evaluation is an useful tool for determining differences among various tissues, including tissues that appear apparently normal on visual analysis. (author)

  4. Total and fission cross-sections of 239Pu - statistical study of resonance parameters

    International Nuclear Information System (INIS)

    Derrien, H.; Blons, J.; Eggermann, C.; Michaudon, A.; Paya, D.; Ribon, P.

    1967-01-01

    The authors measured the total and fission cross-sections of 239 Pu with the linear accelerator at Saclay as a pulsed source of neutrons. The total cross-section was measured in the range from 4 to 700 eV and the best resolution used was 1.5 ns/m; the fission cross-section was measured between 4 eV and 6 keV, the best resolution having been 6 ns/m. The transmission measurements on five samples were made at the temperature of liquid nitrogen, and comparisons made with supplementary experiments at ambient temperature made it possible to determine the Doppler broadening factor (Δ = η√E). The resonances were identified from 4 to 500 eV in the total cross-section; the average level spacing was of the order of 2.4 eV. It would appear that, in this energy range, nearly all the levels were identified. The resonance parameters were determined by analysis of shape in conjunction with a least-squares programme on an IBM-7094 computer. The existence of a large number of broad resonances corresponding to very large fission widths has been shown to exist. Statistical study of the fission widths actually shows the existence of two families of resonances, one corresponding to a mean Γ f of the order of 45 meV and the other to a mean Γ/f of about 750 meV. The authors were therefore able to postulate a classification of resonances in terms of two spin states, the level population ratio in each family being: (2J 1 +1)/(2J 2 +1) = 1/3; J 1 = 0 corresponds to the broad resonances and J 2 = 1 to the narrow ones. The partial widths for radiative capture fluctuate slightly around a mean value of 40 meV. By using a multilevel programme, the authors were able to investigate the extent to which the existence of large fission widths might give rise to fictitious resonances (quasi-resonances) and perturbations and also to make a statistical study of the resonance parameters. (author) [fr

  5. Parameters and definitions in applied technique quality test for nuclear magnetic resonance imaging system (NMRI)

    International Nuclear Information System (INIS)

    Lin Zhikai; Zhao Lancai

    1999-08-01

    During the past two decades, medical diagnostic imaging technique has achieved dramatic development such as CT, MRI, PET, DSA and so on. The most striking examples of them are the application of X ray computerized tomography (CT) and magnetic resonance imaging in the field of medical diagnosis. It can be predicted that magnetic resonance imaging (MRI) will definitely have more widespread prospects of applications and play more and more important role in clinical diagnosis looking forward to the development of image diagnostic technique for 21 st century. The authors also present the measuring methods for some parameters. The parameters described can be used for reference by clinical diagnosticians, operators on MRI and medical physicists who engages in image quality assurance (QA) and control (QC) in performing MRI acceptance test and routine test

  6. Neutron resonance parameters of 96Zr below 100 keV

    International Nuclear Information System (INIS)

    Musgrove, A.R.D.

    1977-08-01

    Transmission data taken at the 80 m station of the Oak Ridge Electron Linear Accelerator have provided resonance parameters for 96 Zr to 100 keV. The average level spacing and neutron strength function for s-wave neutrons were as follows: = 8 +- 2 keV and S 0 = (0.21 +- 0.10) x 10 -4 . The average p-wave neutron strength function was S 1 = (7.4 +- 2.0) x 10 -4 . (Author)

  7. Measurements of the Z boson resonance parameters at SLC [SLAC Linear Collider

    International Nuclear Information System (INIS)

    Hearty, C.

    1989-07-01

    This paper presents the measurement by the Mark II experiment at the SLAC Linear Collider of the parameters of the Z boson resonance. The results are updated from those presented at the SLAC Summer Institute to include all data presented in the most recent Mark II publication, consisting of 19 nb -1 of data at ten different center-of-mass energies between 89.2 and 93.0 GeV. The resonance parameters are extracted by measuring the Z production cross section at a series of center-of-mass energies (scan points) near the Z peak, then fitting these data with the theoretical cross section. The four major aspects of the analysis are the determination at each scan point of the center-of-mass energy (E), the integrated luminosity, the number of Z decays and the expected cross section as a function of the resonance parameters, such as mass and width. I will discuss each of these steps in turn, after a brief description of the Mark II detector, then conclude with the results of the analysis. 7 refs., 9 figs., 3 tabs

  8. Atlas of giant dipole resonances. Parameters and graphs of photonuclear reaction cross sections

    International Nuclear Information System (INIS)

    Varlamov, A.V.; Varlamov, V.V.; Rudenko, D.S.; Stepanov, M.E.

    1999-01-01

    Parameters of giant dipole resonances (GDR) observed in photonuclear reaction cross sections using various beams of incident photons are presented. Data, given for 200 stable isotopes from 2 H to 243 Am including their natural compositions, were collected from papers published over the years 1951-1996. GDR parameters, such as energy positions, amplitudes and widths, are included into the table and organized by element, isotope and reaction. Graphs of the majority of the photonuclear reaction cross sections, included in the international nuclear data library EXFOR by the end of 1998, are presented. The graphs are provided for 182 stable isotopes and natural compositions. (author)

  9. Impact-parameter dependence of giant resonance excitations in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Gruenschloss, A.; Boretzky, K.; Aumann, T.

    1999-09-01

    Angular distributions of Xe fragments produced in peripheral collisions of a 136 Xe beam (700 MeV/nucleon) with 208 Pb and nat Sn targets were measured. Equivalent sharp-cutoff minimum impact parameters were derived on the basis of a semi-classical description for the electromagnetic excitation of one- and two-phonon giant resonances. The results are compared with current standard parametrizations of minimum impact parameters and with the soft-spheres model using realistic mass density distributions for projectile and targets. (orig.)

  10. Resonance parameters for measured keV neutron capture cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Musgrove, A.R. de L

    1969-05-01

    All available neutron capture cross sections in the keV region ({approx} to 100 keV) have been fitted with resonance parameters. Capture cross sections for nuclides with reasonably well known average s-wave parameters, but no measured cross section, have been calculated and tabulated using p-and d- wave strength functions interpolated between fitted values. Several of these nuclides are of interest in the theory of slow nucleosynthesis of heavy elements in stars, and the product of cosmic abundance (due to the s-process) and capture cross section at 30 keV has been plotted versus mass number. (author)

  11. A walk along the steep neutron resonance data evaluation path

    Energy Technology Data Exchange (ETDEWEB)

    Bouland, O. [CEA Cadarache (DEN/CAD/DER/SPRC/LEPh), Physics Studies Lab., 13 - Saint-Paul-lez-Durance (France). Dept. d' Etudes des Reacteurs

    2008-07-01

    This paper goes through some major steps of a 'resonance evaluator' work and in particular on actual tricky questions: the nature of the experimental data base, the life without R-matrix approximations, the external level gambling, the influence of level structures in observables other than cross sections, the puzzling unresolved resonance range and the disused average sub-threshold fission cross sections. (authors)

  12. 56Fe resonance parameters for neutron energies up to 850 keV

    International Nuclear Information System (INIS)

    Perey, C.M.; Perey, F.G.; Harvey, J.A.; Hill, N.W.; Larson, N.M.

    1990-12-01

    High-resolution neutron measurements for 56 Fe-enriched iron targets were made at the Oak Ridge Electron Linear Accelerator (ORELA) in transmission below 20 MeV and in differential elastic scattering below 5 MeV. Transmission measurements were also performed with a natural iron target below 160 keV. The transmission data were analyzed from 5 to 850 keV with the multilevel R-matrix code SAMMY which uses Bayes' theorem for the fitting process. This code provides energies and neutron widths of the resonances inside the 5- to 850-keV energy region, as well as possible parameterization for resonances external to the analyzed region to describe the smooth cross section from a few eV to 850 keV. The resulting set of resonance parameters yields the accepted values for the thermal total and capture cross sections. The differential elastic-scattering data at several scattering angles were compared to theoretical calculations from 40 to 850 keV using the R-matrix code RFUNC based on the Blatt-Biedenharn formalism. Various combinations of spin and parity were tried to predict cross sections for the well defined ell > 0 resonances; comparison of these predictions with the data allowed us to determine the most likely spin and parity assignments for these resonances. The results of a capture data analysis by Corvi et al. (COR84), from 2 to 350 keV, were combined with our results to obtain the radiation widths of the resonances below 350 keV observed in transmission, capture, and differential elastic-scattering experiments

  13. Program RECENT (version 79-1): reconstruction of energy-dependent neutron cross sections from resonance parameters in the ENDF/B format

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1979-01-01

    Program RECENT reconstructs energy-dependent neutron total, elastic, capture, and fission cross sections from a combination of resonance parameters and tabulated background cross sections in the ENDF/B format. Entire evaluations, not just cross sections, are written to the result file, which is in ENDF/B format. The output includes the original resonance parameters in a form that can be used in Doppler broadening and self-shielding calculations. A listing of the source deck is available on request. 5 figures, 5 tables

  14. Evaluation of Control Parameters for the Activated Sludge Process

    Science.gov (United States)

    Stall, T. Ray; Sherrard, Josephy H.

    1978-01-01

    An evaluation of the use of the parameters currently being used to design and operate the activated sludge process is presented. The advantages and disadvantages for the use of each parameter are discussed. (MR)

  15. Magnetic resonance imaging of hypertrophic cardiomyopathy. Evaluation of diastolic function

    International Nuclear Information System (INIS)

    Schwarz, F.; Reiser, M.F.; Theisen, D.; Schwab, F.; Beckmann, B.M.; Schuessler, F.; Kaeaeb, S.; Zinsser, D.; Goelz, T.

    2013-01-01

    Hypertrophic cardiomyopathy (HCM) has a prevalence of approximately 0.2% and is clinically asymptomatic in many patients or presents with unspecific symptoms. This explains the importance of imaging for the diagnosis of HCM as well as for the assessment of the clinical course. The definitive finding in HCM is myocardial hypertrophy with thickening of the ventricular wall ≥ 15 mm. While echocardiography is an excellent screening tool magnetic resonance imaging (MRI) allows a comprehensive analysis of the heart in HCM. This includes a detailed analysis of the distribution and extent of myocardial hypertrophy, a thorough evaluation of systolic and diastolic cardiac function, the assessment of the presence and extent of dynamic outflow tract obstruction as well as the description of the systolic anterior motion (SAM) phenomenon of the mitral valve with secondary mitral insufficiency. When contrast material is administered, additional information about myocardial perfusion as well as the presence and extent of myocardial fibrosis can be obtained. This study compared systolic functional parameters as well as end systolic and end diastolic wall thickness of patients with and without diastolic dysfunction. (orig.) [de

  16. PARAMETERS OF NUCLEAR MAGNETIC RESONANCE IN PATIENTS WITH CONGENITAL NARROWING OF THE LUMBAR SPINAL CANAL

    Directory of Open Access Journals (Sweden)

    ELIU HAZAEL MORALES-RANGEL

    Full Text Available ABSTRACT Objective: To compare the morphological parameters of magnetic resonance in patients with congenital narrowing of the lumbar spinal canal with patients with low back pain. Methods: A descriptive, retrospective, observational study was conducted with measurements in the axial and sagittal magnetic resonance sections of the vertebral body and canal of the lumbar spine of 64 patients with diagnosis of low back pain, which were compared with resonance images taken from 31 Mexican patients with congenital narrowing of the lumbar spinal canal. Results: The results show that patients with congenital narrowing of the lumbar spinal canal in the axial sections have a difference in diameters, being L2<13.9 mm, L3<13.3 mm, L4<12.9 mm, L5<13.1 mm, compared with controls L2<20.5 mm, L3<20.5 mm, L4<19.3 mm, L5<18.1 mm with p = 0.000. Conclusions: We found different measurements in the Mexican population compared to those found by similar studies. With the parameters obtained, it would be possible to make the proper diagnosis, surgical planning, and treatment.

  17. Functional dependence of resonant harmonics on nanomechanical parameters in dynamic mode atomic force microscopy.

    Science.gov (United States)

    Gramazio, Federico; Lorenzoni, Matteo; Pérez-Murano, Francesc; Rull Trinidad, Enrique; Staufer, Urs; Fraxedas, Jordi

    2017-01-01

    We present a combined theoretical and experimental study of the dependence of resonant higher harmonics of rectangular cantilevers of an atomic force microscope (AFM) as a function of relevant parameters such as the cantilever force constant, tip radius and free oscillation amplitude as well as the stiffness of the sample's surface. The simulations reveal a universal functional dependence of the amplitude of the 6th harmonic (in resonance with the 2nd flexural mode) on these parameters, which can be expressed in terms of a gun-shaped function. This analytical expression can be regarded as a practical tool for extracting qualitative information from AFM measurements and it can be extended to any resonant harmonics. The experiments confirm the predicted dependence in the explored 3-45 N/m force constant range and 2-345 GPa sample's stiffness range. For force constants around 25 N/m, the amplitude of the 6th harmonic exhibits the largest sensitivity for ultrasharp tips (tip radius below 10 nm) and polymers (Young's modulus below 20 GPa).

  18. Deep Learning for Magnetic Resonance Fingerprinting: A New Approach for Predicting Quantitative Parameter Values from Time Series.

    Science.gov (United States)

    Hoppe, Elisabeth; Körzdörfer, Gregor; Würfl, Tobias; Wetzl, Jens; Lugauer, Felix; Pfeuffer, Josef; Maier, Andreas

    2017-01-01

    The purpose of this work is to evaluate methods from deep learning for application to Magnetic Resonance Fingerprinting (MRF). MRF is a recently proposed measurement technique for generating quantitative parameter maps. In MRF a non-steady state signal is generated by a pseudo-random excitation pattern. A comparison of the measured signal in each voxel with the physical model yields quantitative parameter maps. Currently, the comparison is done by matching a dictionary of simulated signals to the acquired signals. To accelerate the computation of quantitative maps we train a Convolutional Neural Network (CNN) on simulated dictionary data. As a proof of principle we show that the neural network implicitly encodes the dictionary and can replace the matching process.

  19. Evaluation of urogenital fistulas by magnetic resonance urography

    International Nuclear Information System (INIS)

    Mamere, Augusto Elias; Coelho, Rafael Darahem Souza; Cecin, Alexandre Oliveira; Feltrin, Leonir Terezinha; Lucchesi, Fabiano Rubiao; Seabra, Daniel

    2008-01-01

    Objective: Vesicovaginal and ureterovaginal fistulas are unusual complications secondary to pelvic surgery or pelvic diseases. The therapeutic success in these cases depends on an appropriate preoperative evaluation for diagnosis and visualization of the fistulous tract. The present study is aimed at demonstrating the potential of magnetic resonance urography for the diagnosis of vesicovaginal and ureterovaginal fistulas as well as for defining the fistulous tracts. Materials And Methods: Seven female patients clinically diagnosed with vesicovaginal or ureterovaginal fistulas had their medical records, radiological and magnetic resonance images retrospectively reviewed. Magnetic resonance urography included 3D-HASTE sequences with fat saturation. Results: Six patients presented vesicovaginal fistulas and, in one patient, a right-sided ureterovaginal fistula was diagnosed. Magnetic resonance urography allowed the demonstration of the fistulous tract in six (85.7%) of the seven patients evaluated in the present study, without the need of bladder catheterization or contrast injection. Conclusion: This study demonstrates both the potential and applicability of magnetic resonance urography in the evaluation of these types of fistulas. (author)

  20. POLLA/IECTA, ENDF/B Reich-Moore to Adler-Adler Resonance Parameter Conversion

    International Nuclear Information System (INIS)

    Carlson, B.V.; Chalhoub, E.S.; Melnikoff, M.

    1987-01-01

    1 - Description of program or function: POLLA1 transforms Reich-Moore resolved resonance parameters to the corresponding positive momentum Adler-Adler ones. It is designed to run directly on a file in the ENDF/B format, creating a new file in which the Reich-Moore parameterization has been replaced by the Adler-Adler one. 2 - Method of solution: The Adler-Adler poles are obtained by applying Newton's method to the inverse of the determinant of the Reich-Moore pole matrix. The perturbative solution of R.B. Perez and G. de Saussure, Phys. Rev. C10 (1974)187, is used as a first guess. The residues at the poles are calculated using a simple numerical difference method. 3 - Restrictions on the complexity of the problem: As currently dimensioned, the program permits a maximum of 400 coherent resonances. The transformation itself, which neglects all negative momentum poles, is only accurate for heavy nuclei

  1. A computer code for calculating neutron cross-sections from resonance parameter data

    International Nuclear Information System (INIS)

    Mill, A.J.

    1979-08-01

    A computer code, XSEC, has been written which calculates neutron cross-sections from resonance data. Although the program was originally written in order to identify neutron 'windows' in enriched nuclides, it may be used to evaluate the total neutron cross-section of any medium mass nuclide at intermediate energies. XSEC has proved very useful in identifying suitable nuclides for use as neutron filters at intermediate energies. (author)

  2. Quantitative magnetic resonance techniques in the evaluation of intracranial tuberculomas

    International Nuclear Information System (INIS)

    Vasudev, M.K.; Jayakumar, P.N.; Srikanth, S.G.; Nagarajan, K.; Mohanty, A.

    2007-01-01

    Purpose: To evaluate intracranial tuberculomas using quantitative magnetic resonance (MR) techniques such as T2 relaxometry, magnetization transfer (MT), and diffusion-weighted imaging (DWI). Material and Methods: Thirty-three patients with intracranial tuberculomas (histologically confirmed in 22) were evaluated using proton density/T2-weighted, T1-weighted (with and without MT), and echo-planar diffusion-weighted imaging sequences. T2 relaxation times, MT ratios (MTR), and apparent diffusion coefficient (ADC) values were calculated from the center of the lesion, the periphery, perilesional edema, and contralateral normal white matter. The mean and standard deviation values of each variable were calculated and correlated using Pearson's test (P = 0.05). Results: The measured mean values of T2 relaxation time, MTR, and ADC in the center of lesions were 155.5 ms, 14.1, and 1.27x10-3 mm 2 /s, respectively, compared to 117 ms, 23.72, and 0.74x10-3 mm 2 /s in normal white matter, and a T2 relaxation time of 187.45 ms in normal gray matter. Significant inverse correlations were noted between T2 relaxation values and MTR (P<0.001) and between MTR and ADC (P = 0.046). Significant positive correlation was seen between T2 relaxation and ADC values (P = 0.03). Conclusion: Intracranial tuberculomas are characterized by relatively short T2 relaxation times (compared to normal gray matter), decreased MTR, and mostly no restriction of diffusion. A combination of these quantitative parameters could be of help in the noninvasive diagnosis of tuberculomas

  3. Virtual Acoustics: Evaluation of Psychoacoustic Parameters

    Science.gov (United States)

    Begault, Durand R.; Null, Cynthia H. (Technical Monitor)

    1997-01-01

    Current virtual acoustic displays for teleconferencing and virtual reality are usually limited to very simple or non-existent renderings of reverberation, a fundamental part of the acoustic environmental context that is encountered in day-to-day hearing. Several research efforts have produced results that suggest that environmental cues dramatically improve perceptual performance within virtual acoustic displays, and that is possible to manipulate signal processing parameters to effectively reproduce important aspects of virtual acoustic perception in real-time. However, the computational resources for rendering reverberation remain formidable. Our efforts at NASA Ames have been focused using a several perceptual threshold metrics, to determine how various "trade-offs" might be made in real-time acoustic rendering. This includes both original work and confirmation of existing data that was obtained in real rather than virtual environments. The talk will consider the importance of using individualized versus generalized pinnae cues (the "Head-Related Transfer Function"); the use of head movement cues; threshold data for early reflections and late reverberation; and consideration of the necessary accuracy for measuring and rendering octave-band absorption characteristics of various wall surfaces. In addition, a consideration of the analysis-synthesis of the reverberation within "everyday spaces" (offices, conference rooms) will be contrasted to the commonly used paradigm of concert hall spaces.

  4. A measurement of the Z boson resonance parameters at the SLC [Stanford Linear Center

    International Nuclear Information System (INIS)

    Nash, J.

    1989-11-01

    We have measured the resonance parameters of the Z boson using 480 hadronic and Leptonic Z decays collected by the Mark II Detector at the Stanford Linear Collider. We find the Mass to be 91.14 ± 0.12 GeV/c 2 , and the width to be 2.42 +0.45 -0.35 GeV. If we constrain the visible width to its Standard Model value, we find a partial width to invisible decay modes corresponding to 2.8 ± 0.6 neutrino species with a 95% confidence level limit of 3.9. 9 refs., 1 fig., 4 tabs

  5. Determination of resonance parameters at 4.90 eV for Au 197

    International Nuclear Information System (INIS)

    Tellier, Henry; Alix, Michel

    1969-12-01

    A new study of the 4.9 eV resonance of gold was carried out by the time of flight method using the 45 MeV Saclay linac as a pulsed neutron source. Four sample thicknesses were used for the measurements. The four transmission curves were shaped analysed and the following parameters were obtained: E = 4.900 ± 0.005 eV - Γ = 137.5 ± 2.0 meV and Γ n = 15.0 ± 0.2 meV. (author) [fr

  6. Static fluid magnetic resonance urography in evaluation of ureteral ...

    African Journals Online (AJOL)

    Introduction: Ectopic ureters are often very difficult to diagnose with conventional imaging modalities especially in children. Magnetic resonance urography (MRU) has been recently investigated as a problem-solving tool for the evaluation of various congenital urogenital anomalies with favorable results. Aim of the work: To ...

  7. Processing covariance data for the resonance region - International Evaluation Co-operation, V. 20

    International Nuclear Information System (INIS)

    Dunn, M.; Leal, L.C.; Wiarda, D.; Jacqmin, R.; Kodeli, I.; ); Chiba, G.; Shibata, K.; Ishikawa, M.; Oh, S.; Nikolaev, M.; Kahler, A.C. Jr.; Kawano, T.; Arcilla, R.

    2014-01-01

    A Working Party on International Evaluation Co-operation (WPEC) was established under the sponsorship of the OECD/NEA Nuclear Science Committee (NSC) to promote the exchange of information on nuclear data evaluations, validation, and related topics. Its aim is also to provide a framework for co-operative activities between members of the major nuclear data evaluation projects. Requirements for experimental data resulting from this activity are compiled. The working party determines common criteria for evaluated nuclear data files with a view to assessing and improving the quality and completeness of evaluated data. The parties to the project are ENDF (United States), JEF/EFF (NEA Data Bank member countries), and JENDL (Japan). Cooperation with evaluation projects of non- OECD countries is organized through the Nuclear Data Section of the International Atomic Energy Agency (IAEA). This report summarizes the work performed by WPEC Subgroup 28 (SG28) on issues pertinent to the methodology used to process covariance data in the resonance region. Specifically, SG28 has developed the requisite processing methods needed to process resonance parameter covariance data, generate cross-section covariance data files and demonstrate the use of covariance data in radiation transport analyses. The work performed by SG28 and documented in this report addresses the following tasks: - Produce resonance parameter covariance evaluation for 235 U; - Develop resonance parameter covariance processing methods in widely used processing systems (e.g., NJOY, AMPX, etc.); - Use the updated cross-section processing systems to generate covariance data files for use in radiation transport analyses. In addition, use sensitivity/uncertainty (S/U) analyses to demonstrate the propagation of the covariance data in specific radiation transport applications

  8. The evaluation of set of criticality parameters using scale system

    International Nuclear Information System (INIS)

    Abe, Alfredo; Sanchez, Andrea; Yamaguchi, Mistuo

    2009-01-01

    In evaluating the criticality safety of the nuclear fuel facility, it is important to apply a consistent methodology, which consider every aspects concerning various types of criticality parameters. Usually, the critical parameters are compiled and arranged into handbooks, and these handbooks are based on experience with nuclear facilities, experimental data from criticality safety research facilities, and theoretical studies performed using numerical simulations. Most of criticality safety evaluation can be addressed using the criticality parameters data directly from handbook, but some critical parameters for a specific chemical mixtures and/or enrichment are not be available. Consequently, not available parameters has to be evaluated. This work present the methodology to evaluate a set of critical parameters using SCALE system for various types of mixtures present at nuclear fuel cycle facilities for two different level of enrichment, the results are verified in the independent calculation using MCNP Monte Carlo Code. (author)

  9. A small parameter in the 1/Nsub(c) expansion and narrowness of hadronic resonances

    International Nuclear Information System (INIS)

    Bishari, M.

    1980-01-01

    The dynamical basis for the validity of the 1/Nsub(c) expansion is investigated in the context of QCD in 1+1 dimensions. This is carried out by studying the first non-leading corrections in 1/Nsub(c) to the mass operator in the space of physical states. The correction to the real part of the mass operator has a direct implication for the convergence of the 1/Nsub(c) expansion, since a small effective parameter is identified, where its smallness depends on the dynamical circumstances in a known way. The generated imaginary part of the mass operator provides us with an insight concerning the question of the narrowness of hadronic resonances. In order to have a more realistic contact with our world, we include also effects due to the flavor symmetry group SU(Nsub(f)). This allows us to understand better the validity and usefulness of the notions of resonance dominance and (smooth) Regge behavior. We also discuss the expansion with Nsub(f)/Nsub(c) fixed and compare the results with those obtained from Dual Resonance Model. It is remarked that a non-uniformity exists between the limits Nsub(c) → infinity, Nsub(f) = fixed and Nsub(c) → infinity Nsub(f)/Nsub(c) = fixed, which may affect physical quantities. (author)

  10. A magnetic resonance imaging study on the articulatory and acoustic speech parameters of Malay vowels.

    Science.gov (United States)

    Zourmand, Alireza; Mirhassani, Seyed Mostafa; Ting, Hua-Nong; Bux, Shaik Ismail; Ng, Kwan Hoong; Bilgen, Mehmet; Jalaludin, Mohd Amin

    2014-07-25

    The phonetic properties of six Malay vowels are investigated using magnetic resonance imaging (MRI) to visualize the vocal tract in order to obtain dynamic articulatory parameters during speech production. To resolve image blurring due to the tongue movement during the scanning process, a method based on active contour extraction is used to track tongue contours. The proposed method efficiently tracks tongue contours despite the partial blurring of MRI images. Consequently, the articulatory parameters that are effectively measured as tongue movement is observed, and the specific shape of the tongue and its position for all six uttered Malay vowels are determined.Speech rehabilitation procedure demands some kind of visual perceivable prototype of speech articulation. To investigate the validity of the measured articulatory parameters based on acoustic theory of speech production, an acoustic analysis based on the uttered vowels by subjects has been performed. As the acoustic speech and articulatory parameters of uttered speech were examined, a correlation between formant frequencies and articulatory parameters was observed. The experiments reported a positive correlation between the constriction location of the tongue body and the first formant frequency, as well as a negative correlation between the constriction location of the tongue tip and the second formant frequency. The results demonstrate that the proposed method is an effective tool for the dynamic study of speech production.

  11. Determination of the hadronic resonance parameters of the Zo boson with DELPHI spectrometers at LEP

    International Nuclear Information System (INIS)

    Djama, F.

    1991-05-01

    The work described was achieved on the DELPHI experiment at the LEP e + e - collider. It concerns the determination of the resonance parameters of the Z 0 boson (M z , Γ z and σ o ) through its hadronic decays. The cross-section for the production of quark-antiquark pairs in e + e - collisions was measured at 17 different collision energies close to the resonance peak. At first, a general review of the Standard Model and its predictions for the cross-section of the process e + e - → γ, Z 0 → qantiq are given, followed by a description of the LEP collider and of the DELPHI detector. The different steps of the analysis are then exposed. They concern the luminosity measurement, the selection of the hadronic events and the computation of the experimental cross-sections. Special attention was given to the systematic errors. In order to extract the resonance parameters and to test the Standard Model, the experimental cross-sections were fitted with a theoretical formula which includes the most up-to-date radiative corrections calculations. A three parameter fit gives: M z = 91.183 ± 0.011 (stat) ± 0.02 (LEP) GeV/c 2 Γ z = 2.465 ± 0.020 (stat) ± 0.005 (syst) GeV σ o = 41.92 ± 0.22 (stat) ± 0.33 (syst) ± 0.21 (theo) nb Χ 2 /d.o.f = 8.5/17 - 3. By combining these results with the Standard Model predictions for the leptonic widths, we derived the invisible width of the Z 0 resonance: Γ inv = 486 ± 7 (stat) ± 12 (syst) MeV. This result leads to the following value for the number of the light Dirac neutrino species: N ν = 2.92 ± 0.04 (stat) ± 0.07 (syst). The total and invisible widths were used to derive lower bounds of the masses of new particles predicted either by the Minimal Standard Model (top quark) or by its extensions and alternatives (4 th sequential family, sparticles, excited fermions) [fr

  12. Practice Parameter for Child and Adolescent Forensic Evaluations

    Science.gov (United States)

    Journal of the American Academy of Child & Adolescent Psychiatry, 2011

    2011-01-01

    This Parameter addresses the key concepts that differentiate the forensic evaluation of children and adolescents from a clinical assessment. There are ethical issues unique to the forensic evaluation, because the forensic evaluator's duty is to the person, court, or agency requesting the evaluation, rather than to the patient. The forensic…

  13. Effect of resonance decays on extracted kinetic freeze-out parameters in heavy ion collisions at RHIC

    International Nuclear Information System (INIS)

    Molnar, Levente; Barannikova, Olga; Wang, Fuqiang

    2006-01-01

    Statistical model fit to particle ratios in Au+Au collisions at RHIC suggests chemical freeze-out near phase transition boundary. Model interpretations of evolution from chemical to kinetic freeze-out vary. Results of the blast-wave fit to the STAR experimental data, where resonance contributions are not accounted for, suggest significant cooling and expansion between the freezeouts for central Au+Au collisions. Other models including resonances, argue for instant single freezeout with temperature close to the phase transition temperature. By combined thermal and blast-wave model parametrization including resonances, we systematically investigate the effect of resonance decays on the extracted kinetic freeze-out parameters. (authors)

  14. Relationships between nuclear magnetic resonance parameters used to characterize weathering spilled oil and soil toxicity in central Patagonia.

    Science.gov (United States)

    Ríos, Stella Maris; Barquin, Mercedes; Katusich, Ofelia; Nudelman, Norma

    2014-01-01

    Oil spill in the Central Patagonian zone was studied to evaluate if any relationship exists between the parameters used to characterize weathering spilled oil and soil toxicity for two plant species and to evaluate if the phytotoxicity to local species would be a good index for the soil contamination. Nuclear magnetic resonance (NMR) structural indexes and column chromatography compositional indexes were determined to characterize the oil spill in the soil samples. Bioassays were also carried out using Lactuca sativa L (reference) and Atriplex lampa (native species) as test organisms. Measurements of the total petroleum hydrocarbon (TPH) and the electrical conductivity (EC) of the soil were carried out to evaluate the effect on the bioassays. The principal components analysis of the parameters determined by NMR, compositional indexes, EC, TPH, and toxicology data shows that the first three principal components accounted for the 78% of the total variance (40%, 25%, and 13% for the first, second, and third PC, respectively). A good agreement was found between information obtained by compositional indexes and NMR structural indexes. Soil toxicity increases with the increase of EC and TPH. Other factors, such as, the presence of branched and aromatic hydrocarbons is also significant. The statistical evaluation showed that the Euclidean distances (3D) between the background and each one of the samples might be a better indicator of the soil contamination, compared with chemical criterion of TPH.

  15. Magnetic resonance imaging in the evaluation of periosteal reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino, E-mail: marcello@fmrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Sa, Jose Luiz de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Oliveira, Rodrigo Cecilio Vieira de [Clinica de Diagnostico por Imagem Tomoson, Aracatuba, SP (Brazil); Engel, Edgard Eduard [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Biomecanica, Medicina e Reabilitacao do Aparelho Locomotor

    2010-07-15

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  16. Magnetic resonance imaging in the evaluation of periosteal reactions

    International Nuclear Information System (INIS)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino; Engel, Edgard Eduard

    2010-01-01

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  17. Simulation Research of Magnetically-coupled Resonant Wireless Power Transfer System with Single Intermediate Coil Resonator Based on S Parameters Using ANSYS

    Directory of Open Access Journals (Sweden)

    Liu Cheng

    2016-01-01

    Full Text Available ANSYS can be a powerful tool to simulate the process of energy exchange in magnetically-coupled resonant wireless power transfer system. In this work, the MCR-WPT system with single intermediate coil resonator is simulated and researched based on scattering parameters using ANSYS Electromagnetics. The change rule of power transfer efficiency is reflected intuitively through the scattering parameters. A new method of calculating the coupling coefficient is proposed. A cascaded 2-port network model using scattering parameters is adopted to research the efficiency of transmission. By changing the relative position and the number of turns of the intermediate coil, we find some factors affecting the efficiency of transmission. Methods and principles of designing the MCR-WPT system with single intermediate coil resonator are obtained. And these methods have practical value with design and optimization of system efficiency.

  18. Apparent Diffusion Coefficient and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Pancreatic Cancer: Characteristics and Correlation With Histopathologic Parameters.

    Science.gov (United States)

    Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi

    2016-01-01

    To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.

  19. Computer code ENDSAM for random sampling and validation of the resonance parameters covariance matrices of some major nuclear data libraries

    International Nuclear Information System (INIS)

    Plevnik, Lucijan; Žerovnik, Gašper

    2016-01-01

    Highlights: • Methods for random sampling of correlated parameters. • Link to open-source code for sampling of resonance parameters in ENDF-6 format. • Validation of the code on realistic and artificial data. • Validation of covariances in three major contemporary nuclear data libraries. - Abstract: Methods for random sampling of correlated parameters are presented. The methods are implemented for sampling of resonance parameters in ENDF-6 format and a link to the open-source code ENDSAM is given. The code has been validated on realistic data. Additionally, consistency of covariances of resonance parameters of three major contemporary nuclear data libraries (JEFF-3.2, ENDF/B-VII.1 and JENDL-4.0u2) has been checked.

  20. Progress on chinese evaluated nuclear parameter library: Pt.5

    Energy Technology Data Exchange (ETDEWEB)

    Zongdi, Su; Zhongfu, Huang; Jianfeng, Liu [and others

    1996-06-01

    The progress on chinese evaluated nuclear parameter library (v) was introduced. Six sub-libraries, MCC, DLS, NLD, GDP, FBP and OMP, including their data files and management-retrieval code systems have all been finished. All six sub-libraries have been used in nuclear model calculations, nuclear data evaluations and other fields in China. The applied results show that our evaluated nuclear parameter library is satisfactory and convenient.

  1. Objective parameters for engine noise quality evaluation; Objektive Parameter zur Bewertung der Motorgeraeuschqualitaet

    Energy Technology Data Exchange (ETDEWEB)

    Graf, Bernhard; Brandl, Stephan [AVL List GmbH, Graz (Austria); Sontacchi, Alois [Univ. fuer Musik und Darstellende Kunst, Graz (Austria). Inst. fuer Elektronische Musik und Akustik; Girstmair, Josef [Kompetenzzentrum Das Virtuelle Fahrzeug, Graz (Austria). Gruppe Antriebsstrang Dynamik und Akustik

    2013-06-01

    Due to ongoing downsizing efforts and more stringent emission regulations, relevance of sound quality monitoring during engine and vehicle development is strongly increasing. Therefore AVL developed new sound quality parameters like CKI (Combustion Knocking Index) and HI (Harshness Index). Using these parameters sound quality can be objectively monitored, without subjective evaluations, online throughout the complete development process. (orig.)

  2. Evaluation of congenital heart disease by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Roos, A. de; Roest, A.A.W.

    2000-01-01

    Magnetic resonance imaging has proven to be useful in the assessment of patients with complex congenital heart disease and in the post-surgical follow-up of patients with corrected congenital heart disease. A thorough understanding of the congenital cardiac malformations that can be encountered is needed and the use of the sequential segmental analysis helps to standardize the evaluation and diagnosis of (complex) congenital heart disease. After surgical correction of congenital heart defects, patients must be followed over extended periods of time, because morphological and functional abnormalities may still be present or may develop. The use of echocardiography may be hampered in these patients as scar tissue and thorax deformities limit the acoustic window. Magnetic resonance imaging has proven to be advantageous in the follow-up of these post-surgical patients and with the use of several different techniques the morphological as well as functional abnormalities can be evaluated and followed over time. (orig.)

  3. Evaluation in the resonance range of nuclei with a mass number above 220

    International Nuclear Information System (INIS)

    Ribon, P.

    1970-01-01

    The author discusses the problems posed by the evaluation of neutron data for fissile or fertile nuclei in the range of resolved or unresolved resonances. It appears to take several years until the data of an experiment are used by the reactor physicists. If one wants to have recent data at one's disposal, one cannot have recourse to evaluated-data libraries. Moreover, the existing parameter sets are only fragmentary. A new evaluation is, therefore, necessary for nearly all of these nuclei, but it cannot be based upon different parameter sets; these are indeed contradictory, and the evaluator will have to go back to the original data. The author shows for the set of σ f of 235 U, that a careful comparison of the data shows up unsuspected local defects. Some examples illustrate the deviation between analyses carried out by different methods and between the results on the established divergences. The parameters or cross-sections are far from being known with the precision one would desire. This fact gives rise to anomalies in the interpretation of data necessary for understanding and simulation in the range of unresolved resonances. But the introduction of concepts connected with sub-threshold fission noticeably furthers this understanding. Therefore a comparison of the methods of analysis must be made in more and more accurate measurements (evaluation and correction of systematic errors). (author) [fr

  4. Evaluation of Body Weight and Other Linear Parameters of Marshall ...

    African Journals Online (AJOL)

    This study was designed to evaluate the body weight and other linear parameters of Marshall Broiler for repeatability estimates. A total of one hundred (100) broiler chickens (Marshall) was used in estimating the repeatability of body weight and linear parameters of day old from 2 to 8 weeks of age. Body weight (BW) and ...

  5. Evaluation of physico-chemical parameters of agricultural soils ...

    African Journals Online (AJOL)

    Evaluation of physico-chemical parameters of agricultural soils irrigated by the waters of the hydrolic basin of Sebou River and their influences on the transfer of trace elements into sugar crops (the case of sugar cane)

  6. Performance Evaluation and HaematologicalParameters of West ...

    African Journals Online (AJOL)

    Performance Evaluation and HaematologicalParameters of West African Dwarf Goats Fed Diet Containing Graded Level of Raw and Fermented Malted Sorghum ... influenced white blood cell count (WBC), lymphocytes, monocytes, basophil and mean corpuscular haemoglobin concentration across the dietary treatments.

  7. JUPITER PROJECT - JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY

    Science.gov (United States)

    The JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) project builds on the technology of two widely used codes for sensitivity analysis, data assessment, calibration, and uncertainty analysis of environmental models: PEST and UCODE.

  8. Operating and mathematical representation of resonances between flow parameters oscillations and structure vibrations of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Proskuryakov, K.N.; Yang Shan Afshar, E.; Polyakov, N.I. [Nuclear Power Plant Department of Moscow Power Engineering Institute Technical Univ., Moscow (Russian Federation)

    2007-07-01

    The experimental data that have been obtained from the measurements of noise signals in primary circuit of NPP with reactor of WWER-1000 are presented. The causes of resonant interaction between Eigen-Frequencies of Oscillations of the Coolant Pressure (EFOCP) and structure vibrations are discussed. An application-oriented approach to the problem of identification of abnormal phenomena of thermal-hydraulic parameters is proposed. Logarithmic Decrement {delta} is determined. The bigger damping ratio {zeta} provides bigger {delta} and correspondingly smaller values of Q-factor and amplitude X(t)max. All experimental units intended for NPP severe accident investigation must satisfy to the NPP Q-factor criterion of similarity. (authors)

  9. Operating and mathematical representation of resonances between flow parameters oscillations and structure vibrations of NPP

    International Nuclear Information System (INIS)

    Proskuryakov, K.N.; Yang Shan Afshar, E.; Polyakov, N.I.

    2007-01-01

    The experimental data that have been obtained from the measurements of noise signals in primary circuit of NPP with reactor of WWER-1000 are presented. The causes of resonant interaction between Eigen-Frequencies of Oscillations of the Coolant Pressure (EFOCP) and structure vibrations are discussed. An application-oriented approach to the problem of identification of abnormal phenomena of thermal-hydraulic parameters is proposed. Logarithmic Decrement δ is determined. The bigger damping ratio ζ provides bigger δ and correspondingly smaller values of Q-factor and amplitude X(t)max. All experimental units intended for NPP severe accident investigation must satisfy to the NPP Q-factor criterion of similarity. (authors)

  10. Evaluation of coronary artery bypass grafts with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okamura, Yoshitaka; Yamada, Yasuyuki; Mochizuki, Yoshihiko; Iida, Hiroshi; Mori, Hideaki; Sugita, You-ichi; Shimada, Kou-ichirou

    1997-01-01

    Currently, the efficacy of magnetic resonance imaging (MRI) for evaluating coronary artery disease has been reported. In this study, we have evaluated the usefulness and the problems of MRI for evaluating the patency of coronary artery bypass grafts. Thirty-five patients who received coronary artery bypass grafting (CABG) were evaluated by using MRI for determining the graft patency compared with conventional coronary angiography. There were 30 men and 5 women. The mean age was 61.2 years (range 45 to 75). The 35 patients had a total of 92 grafts (28 internal thoracic artery, 7 gastroepiploic artery and 57 saphenous vein grafts). Magnetic resonance coronary angiogram (MRCA) was performed with SIGNA HORIZON 1.5 T (GE Inc.) by using 2D-FASTCARD sequence. All patients underwent imaging in the transverse and coronal planes, most had imaging in the sagittal plane, and a few had in the oblique plane. By using MRCA, 82 of 90 grafts were diagnosed correctly as patent, and 1 of 2 grafts were diagnosed correctly as occluded. Thirty-four of 40 LAD grafts (85%), 20 of 22 RCA grafts (91%) and 29 of 30 Cx grafts (97%) were correctly evaluated. The efficacy of MRCA for evaluating the patency of coronary artery bypass grafts was recognized. But the sternal wire (stainless steel) and hemoclip interfere with the interpretation and reduce the sensitivity. Higher sensitivity may be obtained by changing the material of the sternal wires and hemoclips at coronary surgery. (author)

  11. Authentication Sensing System Using Resonance Evaluation Spectroscopy (ASSURES)

    Science.gov (United States)

    Trolinger, James D.; Dioumaev, Andrei K.; Lal, Amit K.; Dimas, Dave

    2017-08-01

    This paper describes an ongoing instrument development project to distinguish genuine manufactured components from counterfeit components; we call the instrument ASSURES (Authentication Sensing System Using Resonance Evaluation Spectroscopy). The system combines Laser Doppler Vibrometry with acoustical resonance spectroscopy, augmented with finite element analysis. Vibrational properties of components, such as resonant modes, damping, and spectral frequency response to various forcing functions depend strongly upon the mechanical properties of the material, including its size, shape, internal hardness, tensile strength, alloy/composite compositions, flaws, defects, and other internal material properties. Although acoustic resonant spectroscopy has seen limited application, the information rich signals in the vibrational spectra of objects provide a pathway to many new applications. Components with the same shape but made of different materials, different fatigue histories, damage, tampering, or heat treatment, will respond differently to high frequency stimulation. Laser Doppler Vibrometry offers high sensitivity and frequency bandwidth to measure the component's frequency spectrum, and overcomes many issues that limit conventional acoustical resonance spectroscopy, since the sensor laser beam can be aimed anywhere along the part as well as to multiple locations on a part in a non-contact way. ASSURES is especially promising for use in additive manufacturing technology by providing signatures as digital codes that are unique to specific objects and even to specific locations on objects. We believe that such signatures can be employed to address many important issues in the manufacturing industry. These include insuring the part meets the often very rigid specifications of the customer and being able to detect non-visible internal manufacturing defects or non-visible damage that has occurred after manufacturing.

  12. Evaluation of self-interaction parameters from binary phase diagrams

    International Nuclear Information System (INIS)

    Ellison, T.L.

    1977-10-01

    The feasibility of calculating Wagner self-interaction parameters from binary phase diagrams was examined. The self-interaction parameters of 22 non-ferrous liquid solutions were calculated utilizing an equation based on the equality of the chemical potentials of a component in two equilibrium phases. Utilization of the equation requires the evaluation of the first and second derivatives of various liquidus and solidus data at infinite dilution of the solute component. Several numerical methods for evaluating the derivatives of tabular data were examined. A method involving power series curve fitting and subsequent differentiation of the power series was found to be the most suitable for the interaction parameter calculations. Comparison of the calculated self-interaction parameters with values obtained from thermodynamic measurements indicates that the Wagner self-interaction parameter can be successfully calculated from binary phase diagrams

  13. Computational code in atomic and nuclear quantum optics: Advanced computing multiphoton resonance parameters for atoms in a strong laser field

    Science.gov (United States)

    Glushkov, A. V.; Gurskaya, M. Yu; Ignatenko, A. V.; Smirnov, A. V.; Serga, I. N.; Svinarenko, A. A.; Ternovsky, E. V.

    2017-10-01

    The consistent relativistic energy approach to the finite Fermi-systems (atoms and nuclei) in a strong realistic laser field is presented and applied to computing the multiphoton resonances parameters in some atoms and nuclei. The approach is based on the Gell-Mann and Low S-matrix formalism, multiphoton resonance lines moments technique and advanced Ivanov-Ivanova algorithm of calculating the Green’s function of the Dirac equation. The data for multiphoton resonance width and shift for the Cs atom and the 57Fe nucleus in dependence upon the laser intensity are listed.

  14. Determination of the resonance parameters for 232Th from high resolution transmission and capture measurements at GELINA

    International Nuclear Information System (INIS)

    Brusegan, A.; Schillebeeckx, P.; Lobo, G.; Borella, A.; Volev, K.; Janeva, N.

    2003-01-01

    To deduce the resonance parameters for 232 Th in the resolved resonance region, high resolution transmission and capture measurements are being performed. The measurements are performed at the Time-Of-Flight facility GELINA. A comparison of experimental data resulting from capture (top) and transmission (bottom) are shown. The transmission measurements are performed at a 50 m flight path. The neutron are detected with a 0.25' thick lithium glass (NE912) placed in an Al sphere and viewed by a 5' EMI KQB photomultiplier orthogonal to the neutron beam axis. The injection of a stabilised light pulse in the detector during the measurements provided an efficient tool to control to better than 1% the gain of the entire electronics. The experimental set-up includes a sample-changer, placed at 23 m from the neutron source, which is driven by the acquisition system. The determination of the flight path length, was based on transmission of the 6.673 eV resonance of 238 U. We summarise, for the different energy regions of interest, the scheduled measurement conditions: the operation frequency of the accelerator and the target thickness. A simultaneous analysis of the data using REFIT will result in the resonance parameters from 0 to 4 keV. We show the result of a resonance shape analysis for the resonances at 21.8 and 23.5 eV. The resulting resonance parameters are important for the energy calibration and normalisation of the capture measurements in both the resolved and unresolved resonance region. The capture measurements are completed and were performed at a 60 m flight path. The sample consisted of a metallic natural thorium disc of 8 cm diameter and 1.0 mm thick, corresponding to a thickness of 3.176 10 -3 at/b. The neutron flux was measured with an ionisation chamber loaded with three back-to-back layers of about 40 μg/cm 2 10 B. The gamma rays, originating from the 232 Th(n,γ) reaction, were detected by four C 6 D 6 -based liquid scintillators (NE230) placed

  15. A measurement of the resonance parameters of the neutral intermediate vector boson

    International Nuclear Information System (INIS)

    Nash, J.A.

    1990-01-01

    This thesis presents a measurement of the Z 0 Boson resonance parameters. The measurement was performed at the Stanford Linear Collider using the Mark II detector. Based on a sample of 480 Hadronic and Leptonic decays, the mass is found to be 91.14 ± 0.12 GeV/c 2 , the total width is 2.42 -0.35 +0.45 GeV, and the peak cross section for all Hadronic events, and for Muon and Tau events with cosθ Thrust < 0. 65 is 45 ± 4 nb. By constraining the visible width to the Standard Model value for 5 quarks and 3 charged leptons, and allowing the invisible width to be a parameter, the width to invisible decay modes is found to be 0.46 ± 0.10 GeV. Assuming this width comes from massless neutrinos, this measurement corresponds to 2.8 ± 0.6 neutrino species. This measurement sets an upper limit of 3.9 neutrino generations at the 95% confidence level, ruling out a fourth generation of Standard Model neutrinos at this level. 54 refs., 65 figs., 11 tabs

  16. Assessment of Abdominal Fat Using High-field Magnetic Resonance Imaging and Anthropometric and Biochemical Parameters.

    Science.gov (United States)

    Al-Radaideh, Ali; Tayyem, Reema; Al-Fayomi, Kholoud; Nimer, Nisreen; Malkawi, Amer; Al-Zu Bi, Rana; Agraib, Lana; Athamneh, Imad; Hijjawi, Nawal

    2016-12-01

    To measure the abdominal subcutaneous fat (SF) and visceral fat (VF) volumes using high-field magnetic resonance imaging (MRI) and to investigate their association with selected anthropometric and biochemical parameters among obese and nonobese apparently healthy participants. A cross-sectional study was conducted by recruiting 167 healthy participants. Abdominal scans were acquired at 3T MRI, and the SF and VF were segmented and their volumes were calculated. Selected anthropometric and biochemical measurements were also determined. A significant difference (P abdominal fat volumes, leptin, resistin, adiponectin and waist circumference. Waist circumferences were measured by tape and MRI. Findings revealed that MRI-measured fat volumes were different between males and females and had a significant (P fat volumes were found to correlate moderately with interleukin-6 and weakly with cholesterol, serum triglyceride and low-density lipoprotein. Except for cholesterol, all measured biochemical variables and abdominal fat volumes in the current study were significantly associated with body mass index. All anthropometric and biochemical parameters showed weak-to-strong associations with the MRI-measured fat volumes. Abdominal fat distribution was different between males and females and their correlations with some lipid profiles were found to be sex dependent. These findings revealed that MRI can be used as an alternative tool for obesity assessment. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  17. Spectroscopic parameters and decays of the resonance Z{sub b}(10610)

    Energy Technology Data Exchange (ETDEWEB)

    Agaev, S.S. [Baku State University, Institute for Physical Problems, Baku (Azerbaijan); Azizi, K. [Dogus University, Department of Physics, Istanbul (Turkey); Institute for Research in Fundamental Sciences (IPM), School of Physics, Tehran (Iran, Islamic Republic of); Sundu, H. [Kocaeli University, Department of Physics, Izmit (Turkey)

    2017-12-15

    The resonance Z{sub b}(10610) is investigated as the diquark-antidiquark Z{sub b} = [bu][bd] state with spin-parity J{sup P} = 1{sup +}. The mass and current coupling of the resonance Z{sub b}(10610) are evaluated using QCD two-point sum rule and taking into account the vacuum condensates up to ten dimensions. We study the vertices Z{sub b}Υ(nS)π (n = 1, 2, 3) by applying the QCD light-cone sum rule to compute the corresponding strong couplings g{sub Z{sub bΥ(nS)π}} and widths of the decays Z{sub b} → Υ(nS)π. We explore also the vertices Z{sub b}h{sub b}(mP)π (m = 1, 2) and calculate the couplings g{sub Z{sub bh{sub b(mP)π}}} and the widths of the decay channels Z{sub b} → h{sub b}(mP)π. To this end, we calculate the mass and decay constants of the h{sub b}(1P) and h{sub b}(2P) mesons. The results obtained are compared with experimental data of the Belle Collaboration. (orig.)

  18. Features of the effect of the parameters of resonance systems with different configurations on the current-voltage characteristics of resonant-tunneling nanostructures in a subterahertz frequency range

    International Nuclear Information System (INIS)

    Aleksanyan, A.A.; Volchkov, N.A.; Dravin, V.A.; Kazakov, I.P.; Karuzskij, A.L.; Murzin, V.N.; Perestoronin, A.V.; Tskhovrebov, A.M.; Shmelev, S.S.

    2014-01-01

    Features of the effect of a subterahertz microwave field on the current characteristics of a resonant-tunneling diode in resonance systems with different configurations have been studied. Changes in the current characteristics of the resonant-tunneling diode under variation of the electrophysical parameters of dielectric and microstrip resonators, in particular high-Q-factor superconducting microstrip resonators, have been experimentally studied and analyzed [ru

  19. Parameter Diversity Induced Multiple Spatial Coherence Resonances and Spiral Waves in Neuronal Network with and Without Noise

    International Nuclear Information System (INIS)

    Li Yuye; Jia Bing; Gu Huaguang; An Shucheng

    2012-01-01

    Diversity in the neurons and noise are inevitable in the real neuronal network. In this paper, parameter diversity induced spiral waves and multiple spatial coherence resonances in a two-dimensional neuronal network without or with noise are simulated. The relationship between the multiple resonances and the multiple transitions between patterns of spiral waves are identified. The coherence degrees induced by the diversity are suppressed when noise is introduced and noise density is increased. The results suggest that natural nervous system might profit from both parameter diversity and noise, provided a possible approach to control formation and transition of spiral wave by the cooperation between the diversity and noise. (general)

  20. Program RESENDD (version 84-07): a program for reconstruction of resonance cross sections from evaluated nuclear data in the ENDF/B format

    International Nuclear Information System (INIS)

    Nakagawa, Tsuneo

    1984-10-01

    RESENDD is a computer program to calculate resonance cross sections from evaluated resonance parameters in the ENDF/B format. This program was improved from RESEND by modifying the multi-level Breit-Wigner formula, adding a function of Doppler broadening, and so on. This report explains functions of RESENDD and describes input data. Some examples are also given. (author)

  1. Theory and experimental verifications of the resonator Q and equivalent electrical parameters due to viscoelastic and mounting supports losses.

    Science.gov (United States)

    Yong, Yook-Kong; Patel, Mihir S; Tanaka, Masako

    2010-08-01

    A novel analytical/numerical method for calculating the resonator Q and its equivalent electrical parameters due to viscoelastic, conductivity, and mounting supports losses is presented. The method presented will be quite useful for designing new resonators and reducing the time and costs of prototyping. There was also a necessity for better and more realistic modeling of the resonators because of miniaturization and the rapid advances in the frequency ranges of telecommunication. We present new 3-D finite elements models of quartz resonators with viscoelasticity, conductivity, and mounting support losses. The losses at the mounting supports were modeled by perfectly matched layers (PMLs). A previously published theory for dissipative anisotropic piezoelectric solids was formulated in a weak form for finite element (FE) applications. PMLs were placed at the base of the mounting supports to simulate the energy losses to a semi-infinite base substrate. FE simulations were carried out for free vibrations and forced vibrations of quartz tuning fork and AT-cut resonators. Results for quartz tuning fork and thickness shear AT-cut resonators were presented and compared with experimental data. Results for the resonator Q and the equivalent electrical parameters were compared with their measured values. Good equivalences were found. Results for both low- and high-Q AT-cut quartz resonators compared well with their experimental values. A method for estimating the Q directly from the frequency spectrum obtained for free vibrations was also presented. An important determinant of the quality factor Q of a quartz resonator is the loss of energy from the electrode area to the base via the mountings. The acoustical characteristics of the plate resonator are changed when the plate is mounted onto a base substrate. The base affects the frequency spectra of the plate resonator. A resonator with a high Q may not have a similarly high Q when mounted on a base. Hence, the base is an

  2. Magnetic resonance imaging evaluation of cruciate ligaments after arthroscopic reconstruction

    Directory of Open Access Journals (Sweden)

    Amit Kharat

    2017-01-01

    Full Text Available Background: Due to increase in road traffic and sports injuries, tears of anterior cruciate ligament (ACL and the posterior cruciate ligament (PCL of the knee are common. Magnetic resonance imaging (MRI is emerging as an important tool of diagnosis and evaluation of these injuries. Methods: We carried out a prospective study on role of MRI on ten patients who had undergone ACL or PCL repair over a period of six months. In this report we present three illustrative cases to capture the spectrum of findings in our series to underline the role of MRI in management of such injuries and discuss the modalities of the procedure. Results: In our series, as demonstrated by the cases, MRI had an important role in diagnosis and evaluation of injuries to the cruciate ligaments. Conclusion: MRI can play an important role, particularly in tertiary centres, in diagnosis and evaluation of reconstructed ACL and PCL ligaments of the knee joint.

  3. Magnetic resonance imaging evaluation of traumatic muscle injuries

    International Nuclear Information System (INIS)

    Dias, Elisa Pompeu; Marchiori, Edson

    2001-01-01

    We evaluated 43 magnetic resonance scans of the leg or thigh of patients suffering from sports trauma. Strains were the most frequent lesions observed. These lesions presented iso- or hypointense signal on T1 and hyperintense signal on T2 images, and were classified according to the intensity of the injury of the fibers into grades 1, 2 and 3. The second most common lesions in these series were contusions that appeared iso- or hypointense on T1 and hyperintense on T2 images. Fibrosis was also observed as low signal lesions on T1 and T2 images. (author)

  4. Evaluation of magnetic resonance imaging of Arnold-Chiari malformation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, Kimihiro; Suga, Masakazu; Takemoto, Motohisa

    1987-06-01

    We evaluated the usefulness of magnetic resonance imaging (MRI) in the diagnosis of the Arnold-Chiari malformation. The patient, a 52-year-old man, complained of dizziness on walking. He initially refused to undergone myelography, but 4 months later, underwent MRI test, which lead to the diagnosis of Arnold-Chiari malformation (I type). Not all patients with symptoms of Arnold-Chiari malformation, syringomyelia, syringobulbia and cervical spinal tumor, undergone myelography, which is an invasive technique, therefore MRI should be the first examination for the patients with disorders involving the craniocervical junction.

  5. Calculation of the neutron activation parameters from recently evaluated nuclear data

    International Nuclear Information System (INIS)

    Lopez Aldama, Daniel; Diaz Martinez, Nereida C.

    1999-01-01

    Neutron Activation Analysis (NAA) requires the values for nuclear data such as the 2200 m/s cross section so, the resonance integral I0, the parameter Q0 and the well-known Westcott factors. The availability of recently evaluated nuclear data libraries as the ENDF/B-VI Rev. 5, JEF 2.2, CENDL-2.1 and JENDL-3.2, makes possible to derive the above quantities from the basic nuclear data. It could be very helpful for those NAA parameters, which are unknown or difficult to measure accurately. The procedure to compute the NAA parameters includes the processing of the evaluated nuclear data and the calculation of each parameter directly from its definition. The evaluated nuclear data libraries ENDF/B-VI Rev. 5 and JENDL 3.2 were selected as the main sources of basic nuclear data. The ENDF pre-processing codes were used for processing the source evaluated data and a modified version of the INTER code was applied to calculate the required NAA integrals. The NAA parameters were computed for more than 30 important isotopes. The obtained results were compared with experimental values whenever possible

  6. A quantitative analysis of the diurnal evolution of Ionospheric Alfvén resonator magnetic resonance features and calculation of changing IAR parameters

    Directory of Open Access Journals (Sweden)

    S. R. Hebden

    2005-07-01

    Full Text Available Resonance features of the Ionospheric Alfvén Resonator (IAR can be observed in pulsation magnetometer data from Sodankylä, Finland using dynamic spectra visualizations. IAR resonance features were identified on 13 of 30 days in October 1998, with resonance structures lasting for 3 or more hours over 10 intervals. The diurnal evolution of the harmonic features was quantified for these 10 intervals using a manual cursor-clicking technique. The resonance features displayed strong linear relationships between harmonic frequency and harmonic number for all of the time intervals studied, enabling a homogeneous cavity model for the IAR to be adopted to interpret the data. This enabled the diurnal variation of the effective size of the IAR to be obtained for each of the 10 time intervals. The average effective size was found to be 530 km, and to have an average variation of 32% over each time interval: small compared to the average variation in Alfvén velocity of 61%. Thus the diurnal variation of the harmonics is chiefly caused by the changing plasma density within the IAR due to changing insolation. This study confirms Odzimek (2004 that the dominating factor affecting the IAR eigenfrequencies is the variation in the Alfvén velocity at the F-layer ion-density peak, with the changing IAR size affecting the IAR eigenfrequencies to a smaller extent. Another IAR parameter was derived from the analysis of the IAR resonance features associated with the phase matching structure of the standing waves in the IAR. This parameter varied over the time intervals studied by 20% on average, possibly due to changing ionospheric conductivity. Keywords. Ionosphere (Auroral ionosphere;Wave propagation – Radio science (Electromagnetic noise and interference

  7. Set up of a method for the adjustment of resonance parameters on integral experiments; Mise au point d`une methode d`ajustement des parametres de resonance sur des experiences integrales

    Energy Technology Data Exchange (ETDEWEB)

    Blaise, P.

    1996-12-18

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.).

  8. Measurement of resonance parameters of orbitally excited narrow B0 mesons.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Akimoto, T; Albrow, M G; González, B Alvarez; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzurri, P; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Beringer, J; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burke, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cordelli, M; Cortiana, G; Cox, C A; Cox, D J; Crescioli, F; Almenar, C Cuenca; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; Derwent, P F; di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Elagin, A; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Genser, K; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heijboer, A; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhr, T; Kulkarni, N P; Kurata, M; Kusakabe, Y; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, E; Lee, H S; Lee, S W; Leone, S; Lewis, J D; Lin, C-S; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lucchesi, D; Luci, C; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Merkel, P; Mesropian, C; Miao, T; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moggi, N; Moon, C S; Moore, R; Morello, M J; Morlok, J; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Griso, S Pagan; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Rekovic, V; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Stuart, D; Suh, J S; Sukhanov, A; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Würthwein, F; Wynne, S M; Xie, S; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zhang, X; Zheng, Y; Zucchelli, S

    2009-03-13

    We report a measurement of resonance parameters of the orbitally excited (L=1) narrow B0 mesons in decays to B;{(*)+}pi;{-} using 1.7 fb;{-1} of data collected by the CDF II detector at the Fermilab Tevatron. The mass and width of the B_{2};{*0} state are measured to be m(B_{2};{*0})=5740.2_{-1.8};{+1.7}(stat)-0.8+0.9(syst) MeV/c;{2} and Gamma(B_{2};{*0})=22.7_{-3.2};{+3.8}(stat)-10.2+3.2(syst) MeV/c;{2}. The mass difference between the B_{2};{*0} and B10 states is measured to be 14.9_{-2.5};{+2.2}(stat)-1.4+1.2(syst) MeV/c;{2}, resulting in a B10 mass of 5725.3_{-2.2};{+1.6}(stat)-1.5+1.4(syst) MeV/c;{2}. This is currently the most precise measurement of the masses of these states and the first measurement of the B_{2};{*0} width.

  9. Evaluation of Parkinson's disease using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Vedolin, Leonardo; Marchiori, Edson; Rieder, Carlos

    2004-01-01

    The objective of this study was to evaluate the magnetic resonance imaging findings in patients with Parkinson's disease. In the period from October 1999 to October 2002, 42 patients with parkinsonism were investigated using a 1.5 T MR equipment. Patients were divided into two groups: patients with Parkinson's disease (n = 26) and patients with atypical Parkinsonian syndrome (n = 16). The results were compared with a control group (n = 18). The following variables were evaluated: thickness of the mesencephalon compact pars, hypointense signal in the putamen, degree of brain atrophy, lesions in the mesencephalon, lesions in the white matter, and the presence of lesions in the posterior-lateral edge of the putamen. Statistical data analysis was carried out using the SPSS program. Results: The mean age was 58.2 years for the Parkinson's disease and control groups, and 60.5 years for the atypical Parkinsonian syndrome group. Patients with Parkinson's disease and atypical Parkinsonian syndromes presented decreased thickness of the compact pars and a higher degree of signal hypointensity in the putamen. Cerebral atrophy was more prominent in the patients with atypical Parkinsonian syndrome. Lesions in mesencephalon and white matter were similar in both groups. The frequency of hyperintense signal in the posterior-lateral edge of the putamen was low within the studied population, although that could suggest multiple-system atrophy. Magnetic resonance imaging allows the detection of brain morphological changes that may help in the diagnosis of Parkinsonian syndromes. (author)

  10. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-01-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts. (author)

  11. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-10-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts.

  12. Higgs boson resonance parameters and the finite temperature phase transition in a chirally invariant Higgs-Yukawa model

    Energy Technology Data Exchange (ETDEWEB)

    Bulava, John; Jansen, Karl [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Gerhold, Philip; Kallarackal, Jim; Nagy, Attila [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Humbolt-Univ. Berlin (Germany)

    2011-12-15

    We study a chirally invariant Higgs-Yukawa model regulated on a space-time lattice. We calculate Higgs boson resonance parameters and mass bounds for various values of the mass of the degenerate fermion doublet. Also, first results on the phase transition temperature are presented. In general, this model may be relevant for BSM scenarios with a heavy fourth generation of quarks. (orig.)

  13. Evaluation of trapping parameters of annealed natural quartz

    International Nuclear Information System (INIS)

    Zhou, Rui; Wei, Ming-Jian; Song, Bo; Zhang, Yan; Zhao, Qiu-Yue; Pan, Bao-Lin; Li, Teng-Fei

    2016-01-01

    The thermoluminescence (TL) trapping parameters of annealed quartz have been investigated. The apparent TL peaks observed at temperatures of 133 °C, 211 °C, 266 °C and 405 °C, respectively, were named Peak I, Peak II, Peak III and Peak IV. The T_m − T_s_t_o_p method is applied to investigate the number of peaks and their positions, and to obtain the trap distributions in the quartz. Peak shape (PS), Hoogenstraaten method (Various Heating Rates Method, VHR), and Computerized Glow Curve Deconvolution (CGCD) are used to evaluate the trapping parameters of the annealed quartz. The glow curve can be considered as a superposition of at least nine overlapping peaks. These peaks show up at 133 °C, 211 °C, 266 °C, 308 °C, 333 °C, 384 °C, 441 °C, 466 °C and 484 °C. The PS method can be only used in evaluating the parameters for Peaks I. The VHR method can be used in evaluating the trapping parameters for the first three peaks. CGCD method is complementary to obtaining parameters for the sub-peaks, and the thermal quenching correction with the Urbach’s method is necessary. The Urbach’s coefficient for the quartz is 30.03 kT_m.

  14. Evaluation of trapping parameters of annealed natural quartz

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Rui [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Shisanling Seismic Station, Institute of Earthquake Science, CEA, 102200 Beijing (China); Wei, Ming-Jian, E-mail: weimj@cnu.edu.cn [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Song, Bo [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Beijing Jing Yuan School, 100040 Beijing (China); Zhang, Yan [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); School of TaiPingqiao, Nan Lu of West Railway Station, 100073 Beijing (China); Zhao, Qiu-Yue [Key Laboratory of Tourism and Resources Environment in Universities of Shandong, Taishan University, 271000 Tai’an (China); Pan, Bao-Lin; Li, Teng-Fei [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China)

    2016-05-15

    The thermoluminescence (TL) trapping parameters of annealed quartz have been investigated. The apparent TL peaks observed at temperatures of 133 °C, 211 °C, 266 °C and 405 °C, respectively, were named Peak I, Peak II, Peak III and Peak IV. The T{sub m} − T{sub stop} method is applied to investigate the number of peaks and their positions, and to obtain the trap distributions in the quartz. Peak shape (PS), Hoogenstraaten method (Various Heating Rates Method, VHR), and Computerized Glow Curve Deconvolution (CGCD) are used to evaluate the trapping parameters of the annealed quartz. The glow curve can be considered as a superposition of at least nine overlapping peaks. These peaks show up at 133 °C, 211 °C, 266 °C, 308 °C, 333 °C, 384 °C, 441 °C, 466 °C and 484 °C. The PS method can be only used in evaluating the parameters for Peaks I. The VHR method can be used in evaluating the trapping parameters for the first three peaks. CGCD method is complementary to obtaining parameters for the sub-peaks, and the thermal quenching correction with the Urbach’s method is necessary. The Urbach’s coefficient for the quartz is 30.03 kT{sub m}.

  15. Evaluation of safety-parameter display concepts. Final report

    International Nuclear Information System (INIS)

    Woods, D.D.; Wise, J.A.; Hanes, L.F.

    1982-02-01

    New control room equipment designed to improve operator performance must be evaluated before adoption and installation. Two experimental concepts for a Safety Parameters Display System (SPDS) were evaluated to assess benefits and potential problems associated with the SPDS concept and its integration into control room operations. Participants were licensed utility operators undergoing retraining on a nuclear power plant simulator. Both quantitative and qualitative data were collected and analyzed on crew response to seven simulated accident conditions

  16. Determination of neutron resonance parameters of Neptunium 237 between 0 and 500 eV. The covariance matrices of statistical and of systematic origin, relating the resonance parameters, are also given

    International Nuclear Information System (INIS)

    Lepretre, A.; Herault, N.; Brusegan, A.; Noguere, G.; Siegler, P.

    2002-12-01

    This report is a follow up of the report CEA DAPNIA/SPHN-99-04T of Vincent Gressier. In the frame of a collaboration between the 'Commissariat a l'Energie Atomique (CEA)' and the Institute for Reference Materials and Measurement (IRMM, Geel, Belgique), the resonance parameters of neptunium 237 have been determined in the energy interval between 0 and 500 eV. These parameters have been obtained by using the Refit code in analysing simultaneously three transmission experiments. The covariance matrix of statistical origin is provided. A new method, based on various sensitivity studies is proposed for determining also the covariance matrix of systematic origin, relating the resonance parameters. From an experimental viewpoint, the study indicated that, with a large probability, the background spectrum has structure. A two dimensional profiler for the neutron density has been proved feasible. Such a profiler could, among others, demonstrate the existence of the structured background. (authors)

  17. Evaluation of dampers using a resonance adhesion tester

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available This paper describes the diagnostics of dampers using resonant adhesion tester. This kind of test is non-invasive and evaluation is based on the EUSAMA methodology. The main goals of this method were to practically measure and evaluate technical condition of the shock absorbers. However, this method does not measure only damper properties, but the whole axle, too. During measurements, one must take into account the fact that the results can be easily influenced by external factors. These include e.g. wrong tire pressure, different kind of shock absorbers, and tires. The actual testing revealed that the measurement results are also influenced by bad condition of the vehicle axles. If we eliminate all these draw-backs, dampers testing can be very accurate.

  18. Sensitivity of reactor integral parameters to #betta##betta# parameter of resolved resonances of fertile isotopes and to the α values, in thermal and epithermal spectra

    International Nuclear Information System (INIS)

    Barroso, D.E.G.

    1982-01-01

    A sensitivity analysis of reactor integral parameter to more 10% variation in the resolved resonance parameters #betta##betta# of the fertile isotope and the variations of more 10% in the α values (#betta# sub(#betta#)/#betta# sub(f)) of fissile isotopes of PWR fuel elements, is done. The analysis is made with thermal and epithermal spectra, those last generated in a fuel cell with low V sub(M)/V sub(F). The HAMMER system, the interface programs HELP and LITHE and the HAMMER computer codes, were used as a base for this study. (E.G.) [pt

  19. Evaluation of selected sewage sludge gasification technological parameters

    Science.gov (United States)

    Gałko, Grzegorz; Król, Danuta

    2018-02-01

    Evaluation of selected sewage sludge gasification technological parameters was shown in this paper. Degree of carbon conducted in combustible substance and syngas efficiency (technological readiness coefficient) in accordance with equations were calculated. Enthalpy of individual compounds formation and energy balance were calculated in accordance with rule of Hess.

  20. Evaluation of quality parameters of strawberry fruits in modified ...

    African Journals Online (AJOL)

    The objective of the present study is to evaluate the effect of modified atmosphere packaging (MAP) during storage on some quality parameters of strawberries. Strawberries (cv. Camarosa) were harvested when mature, forced air cooled and divided into two groups as fruits in MAP and control. After packaging, fruits were ...

  1. Resonance

    DEFF Research Database (Denmark)

    Petersen, Nils Holger

    2014-01-01

    A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice.......A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice....

  2. POLLA-NESC, Resonance Parameter R-Matrix to S-Matrix Conversion by Reich-Moore Method

    International Nuclear Information System (INIS)

    Saussure, G. de; Perez, R.B.

    1975-01-01

    1 - Description of problem or function: The program transforms a set of r-matrix nuclear resonance parameters into a set of equivalent s-matrix (or Kapur-Peierls) resonance parameters. 2 - Method of solution: The program utilizes the multilevel formalism of Reich and Moore and avoids diagonalization of the level matrix. The parameters are obtained by a direct partial fraction expansion of the Reich-Moore expression of the collision matrix. This approach appears simpler and faster when the number of fission channels is known and small. The method is particularly useful when a large number of levels must be considered because it does not require diagonalization of a large level matrix. 3 - Restrictions on the complexity of the problem: By DIMENSION statements, the program is limited to maxima of 100 levels and 5 channels

  3. Multi-objective Optimization of Large Wind Farm Parameters for Harmonic Instability and Resonance Conditions

    DEFF Research Database (Denmark)

    Ebrahimzadeh, Esmaeil; Blaabjerg, Frede; Wang, Xiongfei

    2016-01-01

    wind farms in order to reduce the resonance probability and guarantee harmonic stability. In fact, a general multiobjective optimization procedure based on the genetic algorithm is proposed to set the poles of the wind farm in a desired location in order to minimize the number of the resonance...

  4. Blind Source Parameters for Performance Evaluation of Despeckling Filters

    Directory of Open Access Journals (Sweden)

    Nagashettappa Biradar

    2016-01-01

    Full Text Available The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI, and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink embedded with Stein’s unbiased risk estimation (SURE. The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  5. Blind Source Parameters for Performance Evaluation of Despeckling Filters.

    Science.gov (United States)

    Biradar, Nagashettappa; Dewal, M L; Rohit, ManojKumar; Gowre, Sanjaykumar; Gundge, Yogesh

    2016-01-01

    The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI), and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink) embedded with Stein's unbiased risk estimation (SURE). The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  6. Magnetic resonance imaging in the evaluation of the brainstem

    International Nuclear Information System (INIS)

    Han, J.S.; Bonstelle, C.T.; Kaufman, B.; Benson, J.E.; Alfidi, R.J.; Clampitt, M.; Van Dyke, C.; Huss, R.G.

    1984-01-01

    Magnetic resonance (MR) images of the brainstem region from 100 normal or asymptomatic individuals were reviewed in addition to those of 17 patients with intra-axial brainstem lesions and 15 patients with extra-axial masses around the brainstem. MR was able to demonstrate consistently the normal anatomy of the brainstem and adjacent cisterns, though the distinction between gray and white matter was seldom possible with the present technology. Masses in and around the brainstem were all accurately identified on MR and its sensitivity was superior to that of x-ray computed tomography (CT). These study results show that despite its technical limitations, MR is presently the examination of choice for the evaluation of brainstem abnormalities and eventually it will undoubtedly replace metrizamide CT cisternography

  7. Atherosclerosis of the carotid artery: evaluation by magnetic resonance angiography.

    Science.gov (United States)

    Wildy, K S; Yuan, C; Tsuruda, J S; Ferguson, M S; Wen, N; Subramaniam, D S; Strandness, D E

    1996-01-01

    Carotid artery atherosclerotic plaques (APs) can lead to brain ischemia, an event shown to correlate with both the degree of stenosis and the composition of the AP. Currently, accurate estimates of stenosis can be obtained by either x-ray angiography or three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA). Our purpose was to determine whether three-dimensional TOF MRA images could also provide information on plaque location, morphology, and composition. Seven pre-endarterectomy patients underwent three-dimensional TOF MRA. After endarterectomy, plaque histology was evaluated. Three-dimensional TOF MRA images contained sufficient soft tissue contrast to differentiate the plaques from the surrounding tissues in all cases. Estimation of plaque morphology had 80% correlation with histology. Finally, intraplaque hemorrhage and calcification were deplicted as regions of moderately high and very low intensity, respectively. These preliminary results suggest that three-dimensional TOF MRA may be useful in studying the development and progression of carotid atherosclerosis.

  8. Photoionization using the xchem approach: Total and partial cross sections of Ne and resonance parameters above the 2 s22 p5 threshold

    Science.gov (United States)

    Marante, Carlos; Klinker, Markus; Kjellsson, Tor; Lindroth, Eva; González-Vázquez, Jesús; Argenti, Luca; Martín, Fernando

    2017-08-01

    The XCHEM approach interfaces well established quantum chemistry packages with scattering numerical methods in order to describe single-ionization processes in atoms and molecules. This should allow one to describe electron correlation in the continuum at the same level of accuracy as quantum chemistry methods do for bound states. Here we have applied this method to study multichannel photoionization of Ne in the vicinity of the autoionizing states lying between the 2 s22 p5 and 2 s 2 p6 ionization thresholds. The calculated total photoionization cross sections are in very good agreement with the absolute measurement of Samson et al. [J. Electron Spectrosc. Relat. Phenom. 123, 265 (2002), 10.1016/S0368-2048(02)00026-9], and with independent benchmark calculations performed at the same level of theory. From these cross sections, we have extracted resonance positions, total autoionization widths, Fano profile parameters, and correlation parameters for the lowest three autoionizing states. The values of these parameters are in good agreement with those reported in earlier theoretical and experimental work. We have also evaluated β asymmetry parameter and partial photoionization cross sections and, from the latter, partial autoionization widths and Starace parameters for the same resonances, not yet available in the literature. Resonant features in the calculated β parameter are in good agreement with the experimental observations. We have found that the three lowest resonances preferentially decay into the 2 p-1ɛ d continuum rather than into the 2 p-1ɛ s one [Phys. Rev. A 89, 043415 (2014), 10.1103/PhysRevA.89.043415], in agreement with previous expectations, and that in the vicinity of the resonances the partial 2 p-1ɛ s cross section can be larger than the 2 p-1ɛ d one, in contrast with the accepted idea that the latter should amply dominate in the whole energy range. These results show the potential of the XCHEM approach to describe highly correlated process

  9. Dosimetry with alanine/electron spin resonance. Measuring and evaluating

    International Nuclear Information System (INIS)

    Anton, M.

    2007-02-01

    In the first part of the present report a short outline of the theoretical foundations in view of the parameters and evaluation programs described in the following is given. The second part described the measurement procedures and the handling of the measuring data including the applied data formats. In the third part the collection SPAD of MATLAB programs is described, which are necessary for the processing of the measurment data and the subsequent evaluations. Routine evaluations can by means of the present graphic user surface simply be performed. But the described routines can (and shall) be used also as kit in order to solve special evaluation problems. The third part closes with a listing of all programs including the online available aid texts. All functions were tested both under MATLAB 6 and under MATLAB 7

  10. Nuclear criticality safety parameter evaluation for uranium metallic alloy

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Andrea; Abe, Alfredo, E-mail: andreasdpz@hotmail.com, E-mail: abye@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Energia Nuclear

    2013-07-01

    Nuclear criticality safety during fuel fabrication process, transport and storage of fissile and fissionable materials requires criticality safety analysis. Normally the analysis involves computer calculations and safety parameters determination. There are many different Criticality Safety Handbooks where such safety parameters for several different fissile mixtures are presented. The handbooks have been published to provide data and safety principles for the design, safety evaluation and licensing of operations, transport and storage of fissile and fissionable materials. The data often comprise not only critical values, but also subcritical limits and safe parameters obtained for specific conditions using criticality safety calculation codes such as SCALE system. Although many data are available for different fissile and fissionable materials, compounds, mixtures, different enrichment level, there are a lack of information regarding a uranium metal alloy, specifically UMo and UNbZr. Nowadays uranium metal alloy as fuel have been investigated under RERTR program as possible candidate to became a new fuel for research reactor due to high density. This work aim to evaluate a set of criticality safety parameters for uranium metal alloy using SCALE system and MCNP Monte Carlo code. (author)

  11. Performance Evaluation and Parameter Identification on DROID III

    Science.gov (United States)

    Plumb, Julianna J.

    2011-01-01

    The DROID III project consisted of two main parts. The former, performance evaluation, focused on the performance characteristics of the aircraft such as lift to drag ratio, thrust required for level flight, and rate of climb. The latter, parameter identification, focused on finding the aerodynamic coefficients for the aircraft using a system that creates a mathematical model to match the flight data of doublet maneuvers and the aircraft s response. Both portions of the project called for flight testing and that data is now available on account of this project. The conclusion of the project is that the performance evaluation data is well-within desired standards but could be improved with a thrust model, and that parameter identification is still in need of more data processing but seems to produce reasonable results thus far.

  12. Predicting Collateral Status With Magnetic Resonance Perfusion Parameters: Probabilistic Approach With a Tmax-Derived Prediction Model.

    Science.gov (United States)

    Lee, Mi Ji; Son, Jeong Pyo; Kim, Suk Jae; Ryoo, Sookyung; Woo, Sook-Young; Cha, Jihoon; Kim, Gyeong-Moon; Chung, Chin-Sang; Lee, Kwang Ho; Bang, Oh Young

    2015-10-01

    Good collateral flow is an important predictor for favorable responses to recanalization therapy and successful outcomes after acute ischemic stroke. Magnetic resonance perfusion-weighted imaging (MRP) is widely used in patients with stroke. However, it is unclear whether the perfusion parameters and thresholds would predict collateral status. The present study evaluated the relationship between hypoperfusion severity and collateral status to develop a predictive model for good collaterals using MRP parameters. Patients who were eligible for recanalization therapy that underwent both serial diffusion-weighted imaging and serial MRP were enrolled into the study. A collateral flow map derived from MRP source data was generated through automatic postprocessing. Hypoperfusion severity, presented as proportions of every 2-s Tmax strata to the entire hypoperfusion volume (Tmax≥2 s), was compared between patients with good and poor collaterals. Prediction models for good collaterals were developed with each Tmax strata proportion and cerebral blood volumes. Among 66 patients, 53 showed good collaterals based on MRP-based collateral grading. Although no difference was noted in delays within 16 s, more severe Tmax delays (Tmax16-18 s, Tmax18-22 s, Tmax22-24 s, and Tmax>24 s) were associated with poor collaterals. The probability equation model using Tmax strata proportion demonstrated high predictive power in a receiver operating characteristic analysis (area under the curve=0.9303; 95% confidence interval, 0.8682-0.9924). The probability score was negatively correlated with the volume of infarct growth (P=0.030). Collateral status is associated with more severe Tmax delays than previously defined. The present Tmax severity-weighted model can determine good collaterals and subsequent infarct growth. © 2015 American Heart Association, Inc.

  13. Impact of the Parameter Variation on the Image Blurring in 3 T Magnetic Resonance Imaging: A Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Woo; Lee, Sang Hoon; Kim, Nam Kug; Cho, Kyung Sik; Lee, Jin Seong [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2013-04-15

    To evaluate the effects of the key imaging-parameter alterations on the four MR sequences in a phantom study. Magnetic resonance (MR) imaging was performed on a MR phantom with an 8-channel head coil by using a 3 T MR system. The images were obtained in the axial plane on four MR sequences [T1-weighted, T2-weighted, Proton-density, and 3 dimensional (3D) fast spin echo (FSE)] with controlled variations in the following key parameters: 1) echo train length (ETL), 2) repetition time (TR), and 3) echo time (TE). The image blurring was determined by the degree of the gradient angle; i.e., the blurring increased as the gradient angle decreases. The increasing ETL was observed to cause an increase in the image blurring on all pulse sequences with a statistical significance (p = 0.004) on the 3D FSE. Increasing the TR appeared to have no effect except a statistically significant decrease on the T1-weighted images (p = 0.011). Increasing TE showed no effect on the T1-weighted images (p = 0.932); however, it caused an increase of blurring on the proton density images (p = 0.016) as well as the T2-weighted images (p < 0.001), and a decrease on the 3D FSE (p = 0.001). To reduce the image blurring, short ETL and long TE for 3D FSE, long TR for T1-weighted images and short TE for proton-density and T2-weighted images should be applied.

  14. Investigation of parameters of the working substance - low temperature plasma in the ionization resonator chamber of the RF reactive engine

    International Nuclear Information System (INIS)

    Vdovin, V.S.; Zajtzev, B.V.; Kobetz, A.F.; Bomko, V.A.; Rashkovan, V.M.; Bazyma, L.A.; Belokon, V.I.

    2003-01-01

    This paper is the extension of investigations of the RF engine designed for orientation and stabilization of the spacecrafts orbit, and it is undertaken for measuring of plasma parameters of RF discharge in the ionization resonator chamber. The experiments were performed at the frequency of 80 MHz on the model engine, in which a length of coaxial line with shortening capacities at the ends was used as the ionization resonator chamber. As the result of the experiments, conditions of the RF discharge ignition in the resonator chamber are studied; dependencies of plasma density and temperature versus applied power and working body pressure are obtained for various gases. The measurements of the thrust were performed at the special-purpose test bench

  15. Analysis and Evaluation of Cooking Parameters for Sweet Bakery Products

    OpenAIRE

    Giuseppe Vignali; Andrea Volpi

    2013-01-01

    Cooking process is essential for the preparation of sweet bakery products, such as Panettone, a typical Italian seasonal dessert. This study is aimed at evaluating the features of the finished product leaving the oven chamber using the Design of Experiments technique. Four features of the product like “water activity”, “humidity”, “pH” and “sensorial judge” have been explained as functions of independent variables: recipe of the dough, affecting the dough strength and cooking process paramete...

  16. Evaluation of safety parameter display concepts. Final report

    International Nuclear Information System (INIS)

    Woods, D.D.; Wise, J.A.; Hanes, L.F.

    1982-02-01

    New control room equipment designed to improve operator performance must be evaluated before adoption and installation. Two experimental concept for a Safety Parameters Display System (SPDS) were evaluated to assess benefits and potential problems associated with the SPDS concept and its integration into control room operations. Participants were licensed utility operators undergoing retraining on a nuclear power plant simulator. Both quantitative and qualitative data were collected and analyzed on crew response to seven simulated accident conditions. Data on operator decisions and actions have been organized into timelines. Analysis of the timelines and observations collected during testing provide important insights about the potential impact of the SPDS concept on control room operations

  17. New WIMS library generation from ENDF/B6 and effect of resonance group structure on cell parameters

    International Nuclear Information System (INIS)

    Pazirandeh, Ali; Tabesh, Alireza

    2002-01-01

    Due to inaccessibility to NJOY, steps were taken to create WIMS library, which can be extracted from ENDF/B6 without using NJOY. In addition to using preprocessing codes few programs were written to calculate integral resonance, slowing down power per unit lethargy, potential scattering, and differential scattering cross section, scattering matrices. For neutrons with energy above 4 eV, isotropic elastic scattering was assumed. For neutrons below 4 eV the free gas model was used, except for light elements, which tabulated values of S(α,β) in ENDF/B6 used. The Goldstein-Cohen factors are taken from WIMKAL88.Lib. The integral resonance with self absorption per unit lethargy was obtained from GROUPIE output. The P 1 scattering matrices are calculated only for four elements, namely H, D, C and O at 300 K. In order to examine the created libraries, k eff , δ 28 , ρ 28 , ρ 25 and CR are calculated using new WIMS library, WIMKAL88.Lib and NEA329.Lib. The results showed general agreement. The controversial issue of WIMS library group structure, particularly in resonance region has raised the question of whether the number of resonance group i.e., 13 is optimized. We generated different WIMS libraries consisting of 5, 8, 13, 18 and 23 resonance groups. The main aim was to examine the effect to resonance group structure on calculated core parameters, mainly, k eff , δ 28 , ρ 28 , ρ 25 and CR. These parameters are also calculated and compared with those obtained using WIMKAL88, and NEA329 libraries. (author)

  18. Evaluation of acoustic resonance at branch section in main steam line. Part 1. Effects of steam wetness on acoustic resonance

    International Nuclear Information System (INIS)

    Uchiyama, Yuta; Morita, Ryo

    2011-01-01

    The power uprating of the nuclear power plant (NPP) is conducted in United States, EU countries and so on, and also is planned in Japan. However, the degradation phenomena such as flow-induced vibration and wall thinning may increase or expose in the power uprate condition. In U.S. NPP, the dryer had been damaged by high cycle fatigue due to acoustic-induced vibration under a 17% extended power uprating (EPU) condition. This is caused by acoustic resonance at the stub pipes of safety relief valves (SRVs) in the main steam lines (MSL). Increased velocity by uprating excites the pressure fluctuations and makes large amplitude resonance. To evaluate the acoustic resonance at the stub pipes of SRVs in actual BWR, it is necessary to clarify the acoustic characteristics in steam flow. Although there are several previous studies about acoustic resonance, most of them are not steam flow but air flow. Therefore in this study, to investigate the acoustic characteristics in steam flow, we conducted steam flow experiments in each dry and wet steam conditions, and also nearly saturated condition. We measured pressure fluctuation at the top of the single stub pipe and in main steam piping. As a result, acoustic resonance in dry steam flow could be evaluated as same as that in air flow. It is clarified that resonance amplitude of fluctuating pressure at the top of the stub pipe in wet steam was reduced to one-tenth compared with that in dry. (author)

  19. Inter- and intra-rater reproducibility of semiautomatic determination of volume parameters in cardiac magnetic resonance imaging

    International Nuclear Information System (INIS)

    Trieb, Thomas; Glodny, Bernhard; Scheiblhofer, Martin; Wolf, Christian; Metzler, Bernhard; Pachinger, Otmar; Jaschke, Werner R.; Schocke, Michael F.H.

    2008-01-01

    Purpose: The purpose of this study was to evaluate inter- and intra-rater reproducibility in volume assessment using cardiac magnetic resonance imaging (CMRI). Methods: Twenty-five healthy volunteers and 106 patients were included into this retrospective study and received CMRI. The patients were divided in three groups (group I, 80 patients with arrhythmia; group II, 20 patients with cardiomyopathy; group III, 6 patients after correction of septum defects). Therefore, the images were semiautomatically segmented by an experienced and an unexperienced radiologists. The analysis of end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV) as well as ejection fraction (EF) and myocardial mass (MM) were performed twice by an experienced and an unexperienced radiologists. The intra-class correlation coefficients (ICC) were determined for the evaluation of inter- and intra-rater variance. Results: The intra-rater reproducibility for determination of EF, ESV, EDV and MM was excellent with ICCs ranging from 0.88 to 0.99 (all p < 0.001). The inter-observer reproducibility for these parameters was also excellent with ICCs ranging from 0.91 to 0.98 (all p < 0.001). The assessment of the SV showed an excellent intra-rater agreement with ICCs of 0.96 and 0.92 (both p < 0.001), but only a moderate ICC for the inter-rater reproducibility (0.54, p < 0.001). Conclusions: Our study shows that assessment of cardiac volumes can be performed on CMRIs with an excellent reproducibility by both experienced and unexperienced investigators

  20. Magnetic resonance imaging in the evaluation of medulloblastomas

    International Nuclear Information System (INIS)

    Tokimura, Hiroshi; Uetsuhara, Koichi; Komasaku, Ryuichiro; Kasamo, Shizuya; Asakura, Tetsuhiko

    1989-01-01

    Five patients with medulloblastomas were evaluated with Magnetic Resonance Imaging (MRI), and the results were compared with those of X-ray computed tomography (CT). On CT, medulloblastomas generally appeared as isodense or hyperdense masses and were enhanced uniformly with a contrast agent. On MRI, medulloblastomas appeared as low-intensity masses in T 1 -weighted images and as high-intensity masses in T 2 -weighted images. Moreover, the tumors were clearly differentiated from the surrounding tissue. In sagittal images, we could easily recognize the relation between the brainstem or the fourth ventiricle and the tumors. In spite of these merits, though, on MRI we could not detect the boundary between the tumors and the perifocal edema. In this point, we had to be dependent on CT. In one case, we could measure the T 1 value and the T 2 value both before and after irradiation. The T 2 value was markedly decreased after irradiation. Henceforth, the T 1 and T 2 values can be used to evaluate the effects of irradiation. Medulloblastomas are often disseminated through cerebrospinal fluid. We could detect this type of metastasis by means of the sagittal image on MRI. As has been mentioned above, MRI is very useful in diagnosing medulloblastomas and for the post-operative follow-up those tumors. (author)

  1. Determination of neutron resonance parameters of Neptunium 237 between 0 and 500 eV. The covariance matrices of statistical and of systematic origin, relating the resonance parameters, are also given; Determination des parametres des resonances neutroniques du neptunium 237, en dessous de 500eV, et obtention des matrices de covariances statistiques et systematiques entre les parametres de ces resonances

    Energy Technology Data Exchange (ETDEWEB)

    Lepretre, A.; Herault, N. [CEA Saclay, Dept. d' Astrophysique de Physique des Particules, de Physique Nucleaire et de l' Instrumentation Associee, 91- Gif sur Yvette (France); Brusegan, A.; Noguere, G.; Siegler, P. [Institut des Materiaux et des Metrologies - IRMM, Joint Research Centre, Gell (Belgium)

    2002-12-01

    This report is a follow up of the report CEA DAPNIA/SPHN-99-04T of Vincent Gressier. In the frame of a collaboration between the 'Commissariat a l'Energie Atomique (CEA)' and the Institute for Reference Materials and Measurement (IRMM, Geel, Belgique), the resonance parameters of neptunium 237 have been determined in the energy interval between 0 and 500 eV. These parameters have been obtained by using the Refit code in analysing simultaneously three transmission experiments. The covariance matrix of statistical origin is provided. A new method, based on various sensitivity studies is proposed for determining also the covariance matrix of systematic origin, relating the resonance parameters. From an experimental viewpoint, the study indicated that, with a large probability, the background spectrum has structure. A two dimensional profiler for the neutron density has been proved feasible. Such a profiler could, among others, demonstrate the existence of the structured background. (authors)

  2. Functional Magnetic Resonance in the Evaluation of Oesophageal Motility Disorders

    Directory of Open Access Journals (Sweden)

    Francesco Covotta

    2011-01-01

    Our aim is to assess the role of fMRI as a technique to assess morphological and functional parameters of the esophagus in patients with esophageal motor disorders and in healthy controls. Subsequently, we assessed the diagnostic efficiency of fMRI in comparison to videofluoroscopic and manometric findings in the investigation of patients with esophageal motor disorders. Considering that fMRI was shown to offer valuable information on bolus transit and on the caliber of the esophagus, variations of these two parameters in the different types of esophageal motor alterations have been assessed. fMRI, compared to manometry and videofluoroscopy, showed that a deranged or absent peristalsis is significantly associated with slower transit time and with increased esophageal diameter. Although further studies are needed, fMRI represents a promising noninvasive technique for the integrated functional and morphological evaluation of esophageal motility disorders.

  3. Evaluating Iron Content and Tissue Microstructure with Off-Resonance Saturation MRI

    Science.gov (United States)

    Fahmy, Sherif R.

    We present three magnetic resonance imaging (MRI) studies, each focused on applying off-resonance saturation (ORS) imaging to a different context or application. Particularly, we are interested in using ORS to evaluate the uptake of superparamagnetic MRI contrast agents in biological tissue, and to evaluate endogenous iron content. This relies on ORS being applied at low off-resonance frequency offsets where most of the negative contrast is due to signal loss from direct saturation of the water content of the sample. Additionally, we wish to combine this information with magnetization transfer contrast, which is obtained by applying ORS at offsets that are far from the resonance frequency, where magnetization transfer (MT) becomes the dominant effect rather than direct saturation (DS). In the first study, we observed the uptake of ultra-small superparamagnetic iron oxide (USPIO) nanoparticles in a simple model system by imaging the uptake in healthy murine liver in vivo, and by testing different metrics to quantify the uptake. Through this process, we discovered an approach that provides high sensitivity and specificity in low-signal scenarios. In the second study, we evaluated image contrast between brain regions in healthy human adults, and related these to the expected iron content in different regions based on age. Images were evaluated based on different MRI contrast mechanisms including quantitative transverse relaxation rates, as well as parameters obtained from ORS imaging. We also performed a field inhomogeneity adjustment on low-offset ORS data using the information obtained from the coarsely sampled ORS spectrum, and this was sufficient to correct for the inhomogeneities. In the third study, we used transverse relaxation, DS - which is strongly dependent on iron content, and MT contrast, in order to classify ex vivo brain samples having Alzheimer's disease pathology and normal controls, and were able to find strong classifiers. The three studies helped

  4. Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

    International Nuclear Information System (INIS)

    Costa, Flavia Martins; Setti, Marcela; Vianna, Evandro Miguelote; Domingues, Romulo Cortes; Meohas, Walter; Rezende, Jose Francisco; Gasparetto, Emerson Leandro

    2009-01-01

    Objective: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. Materials And Methods: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Time signal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. Results: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). Conclusion: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors. (author)

  5. Evaluation of Reliability Parameters in Micro-grid

    Directory of Open Access Journals (Sweden)

    H. Hasanzadeh Fard

    2015-06-01

    Full Text Available Evaluation of the reliability parameters in micro-grids based on renewable energy sources is one of the main problems that are investigated in this paper. Renewable energy sources such as solar and wind energy, battery as an energy storage system and fuel cell as a backup system are used to provide power to the electrical loads of the micro-grid. Loads in the micro-grid consist of interruptible and uninterruptible loads. In addition to the reliability parameters, Forced Outage Rate of each component and also uncertainty of wind power, PV power and demand are considered for micro-grid. In this paper, the problem is formulated as a nonlinear integer minimization problem which minimizes the sum of the total capital, operational, maintenance and replacement cost of DERs. This paper proposes PSO for solving this minimization problem.

  6. The evaluation of some thermodynamic parameters by RIA method

    International Nuclear Information System (INIS)

    Dorobantu, I. I.; Cucu Delia-Irina

    2001-01-01

    The present paper evaluates some of thermodynamic parameters by using RIA (radioimmunoassay) method. The RIA systems studied were: 1) antiprogesterone antibody-progesterone- 3 H; 2) antiprogesterone antibody-progesterone- 125 I. The antigen (progesterone) was labelled with 3 H, in the first case, and 125 I in the second one (progesterone- 125 I was progesterone-6-S-CH 2 -CO-histamine- 125 I). RIA reactions were developed at two temperatures: 277 K and 296 K. Samples of antiprogesterone antibodies and labelled progesterone were incubated with different amounts of unlabeled progesterone. The immune complex was precipitated after reaching the chemical equilibrium and its radioactivity measured at γ-counter. By the radioactive measurements, the affinity constants (K S ) were estimated. The values of the affinity constants were used to estimate the thermodynamic parameters of the systems, such as: enthalpy (ΔH), Gibbs energy (ΔG) and entropy (ΔS). (authors)

  7. RESEND, Infinitely Dilute Point Cross-Sections Calculation from ENDF/B Resonance Parameter. ADLER, ENDF/B Adler-Adler Resonance Parameter to Point Cross-Sections with Doppler Broadening

    International Nuclear Information System (INIS)

    Bhat, M.R.; Ozer, O.

    1982-01-01

    1 - Description of problem or function: RESEND generates infinitely- dilute, un-broadened, point cross sections in the ENDF format by combining ENDF File 3 background cross sections with points calculated from ENDF File 2 resonance parameter data. ADLER calculates total, capture, and fission cross sections from the corresponding Adler-Adler parameters in the ENDF/B File 2 Version II data and also Doppler-broadens cross sections. 2 - Method of solution: RESEND calculations are done in two steps by two separate sections of the program. The first section does the resonance calculation and stores the results on a scratch file. The second section combines the data from the scratch file with background cross sections and prints the results. ADLER uses the Adler-Adler formalism. 3 - Restrictions on the complexity of the problem: RESEND expects its input to be a standard mode BCD ENDF file (Version II/III). Since the output is also a standard mode BCD ENDF file, the program is limited by the six significant figure accuracy inherent in the ENDF formats. (If the cross section has been calculated at two points so close in energy that only their least significant figures differ, that interval is assumed to have converged, even if other convergence criteria may not be satisfied.) In the unresolved range the cross sections have been averaged over a Porter-Thomas distribution. In some regions the calculated resonance cross sections may be negative. In such cases the standard convergence criterion would cause an unnecessarily large number of points to be produced in the region where the cross section becomes zero. For this reason an additional input convergence criterion (AVERR) may be used. If the absolute value of the cross section at both ends of an interval is determined to be less than AVERR then the interval is assumed to have converged. There are no limitations on the total number of points generated. The present ENDF (Version II/III) formats restrict the total number of

  8. TRITOX: a multiple parameter evaluation of tritium toxicity

    International Nuclear Information System (INIS)

    Carsten, A.L.

    1982-01-01

    The increased use of nuclear reactors for power generation will lead to the introduction of tritium into the environment. The need for assessing possible immediate and long-term effects of exposure to this tritium led to the development of a broad program directed towards evaluating the possible somatic and genetic effects of continuous exposure to tritiated water (HTO). Among the parameters measured are the genetic, cytogenetic, reproductive efficiency, growth, nonspecific lifetime shortening, bone marrow cellularity and stem cell content, relative biological effectiveness as compared to 137 Cesium gamma exposure, and related biochemical and microdosimetric evaluations. These parameters have been evaluated on animals maintained on HTO at 10 to 100 times the maximum permissible concentration (0.03 - 3.0 μCi/ml) for HTO. Dominant lethal mutations, chromosome aberrations in regenerating liver, increased sister chromatid exchanges in bone marrow and reduction in bone marrow stem cell content have been observed at the higher concentrations. The relative biological effectiveness for HTO ingestion as compared to external 137 Cesium gamma exposures has been found to be between 1 and 2

  9. Use of magnetic resonance imaging in the evaluation of spondylolysis.

    Science.gov (United States)

    Rush, Jeremy K; Astur, Nelson; Scott, Stephanie; Kelly, Derek M; Sawyer, Jeffrey R; Warner, William C

    2015-01-01

    In early studies, magnetic resonance imaging (MRI) had low sensitivity and positive predictive value in the evaluation of the pars interarticularis pathology; however, more recent reports have suggested an expanded role for MRI. The purpose of the present study was to evaluate the effectiveness of MRI in the diagnosis of pars injuries and compare it to computed tomography (CT), which was used as the reference "gold standard" for the detection of fractures. The radiographic and clinic data of 93 adolescents and young adults with a presumptive diagnosis of spondylolysis based upon history and clinic examination were reviewed. Only 26 patients who had MRI and CT images obtained within 30 days of each other were included. All images were reviewed by a fellowship-trained musculoskeletal radiologist and fellowship-trained pediatric orthopaedist. Overall, 39 individual pars lesions (stress reaction or fracture) were identified. MRI was effective in identifying 36 pars lesions. MRI identified 11 lesions in 9 patients with negative CT. Seven of these lesions were stress reactions (grade 1), whereas 4 were frank fractures. Three pars injuries were noted on CT while the MRI was negative. MRI is an effective method (92% sensitivity) for detecting pars injuries. It can detect stress reactions when a fracture is not visible on CT scan, allowing early treatment of these prelysis lesions. The 92% sensitivity of MRI is comparable with that of other diagnostic modalities such as bone scan, with the advantage of no radiation exposure. MRI should be strongly considered as the advanced imaging modality of choice in the evaluation of patients with suspected spondylolysis. Level III-diagnostic study.

  10. Nondestructive evaluation of warm mix asphalt through resonant column testing.

    Science.gov (United States)

    2014-02-01

    Non-destructive testing has been used for decades to characterize engineering properties of hot-mix asphalt. Among such tests is the resonant column (RC) test, which is commonly used to characterize soil materials. The resonant column device at Penn ...

  11. Resonances

    DEFF Research Database (Denmark)

    an impetus or drive to that account: change, innovation, rupture, or discontinuity. Resonances: Historical Essays on Continuity and Change explores the historiographical question of the modes of interrelation between these motifs in historical narratives. The essays in the collection attempt to realize...

  12. Initial experience of correlating parameters of intravoxel incoherent motion and dynamic contrast-enhanced magnetic resonance imaging at 3.0 T in nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qian-Jun; Zhang, Shui-Xing; Chen, Wen-Bo; Liang, Long; Zhou, Zheng-Gen; Liu, Zai-Yi; Zeng, Qiong-Xin; Liang, Chang-Hong [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Qiu, Qian-Hui [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Otolaryngology, Guangzhou, Guangdong Province (China)

    2014-12-15

    To determine the correlation between intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters. Thirty-eight newly diagnosed NPC patients were prospectively enrolled. Diffusion-weighted images (DWI) at 13 b-values were acquired using a 3.0-T MRI system. IVIM parameters including the pure molecular diffusion (D), perfusion-related diffusion (D*), perfusion fraction (f), DCE-MRI parameters including maximum slope of increase (MSI), enhancement amplitude (EA) and enhancement ratio (ER) were calculated by two investigators independently. Intra- and interobserver agreement were evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Relationships between IVIM and DCE-MRI parameters were evaluated by calculation of Spearman's correlation coefficient. Intra- and interobserver reproducibility were excellent to relatively good (ICC = 0.887-0.997; narrow width of 95 % limits of agreement). The highest correlation was observed between f and EA (r = 0.633, P < 0.001), with a strong correlation between f and MSI (r = 0.598, P = 0.001). No correlation was observed between f and ER (r = -0.162; P = 0.421) or D* and DCE parameters (r = 0.125-0.307; P > 0.119). This study suggests IVIM perfusion imaging using 3.0-T MRI is feasible in NPC, and f correlates significantly with EA and MSI. (orig.)

  13. Resolved resonance parameters for uranium 238 from 4 to 6 keV

    International Nuclear Information System (INIS)

    Olsen, D.K.; Meszaros, P.S.

    1982-01-01

    Neutron widths for 145 resonances from 4 to 6 keV are reported from a least-squares shape analysis of the ORELA 150-m, 4-sample 238 U transmission data. The resultant s-wave strength function from 4 to 6 keV is found to be substantially smaller than that from 0 to 4 keV

  14. Suspected invasive placenta: evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bour, Laurence; Place, Vinciane; Bendavid, Sandra; Fargeaudou, Yann; Portal, Jean-Jacques; Ricbourg, Aude; Sebbag, Delphine; Dohan, Anthony; Soyer, Philippe; Vicaut, Eric

    2014-01-01

    To determine the utility of magnetic resonance imaging (MRI) in diagnosing invasive placenta (IP). MRI findings in 32 women with suspected IP were evaluated independently by four readers. Interobserver agreement was calculated with kappa (κ) statistics. Associations between MRI findings and IP were assessed by univariate and multivariate analyses. Sensitivity, specificity and accuracy of MRI for the diagnosis of IP were estimated. Sixteen women (16/32; 50 %) had confirmed IP. Interobserver correlation for the diagnosis of IP was fair (κ = 0.40). Univariate analysis revealed that thinning or focal defect of the uteroplacental interface (P < 0.0001) was the most discriminating MRI variable in the differentiation between normal and IP. Overall sensitivity and specificity of MRI for the diagnosis of IP were 84 % [95 % CI: 75-94 %] and 80 % [95 % CI: 66-93 %], respectively. Thinning or focal defect of the uteroplacental interface was the most accurate finding (88 %) in the diagnosis of IP. Multivariate analysis revealed that thinning or focal defect of the uteroplacental interface was the single independent predictor of IP (P = 0.0006; OR = 64.99). MR imaging has 84 % sensitivity [95 % CI: 75-94 %] and 80 % specificity [95 % CI: 66-93 %] for the diagnosis of IP. Thinning or focal defect of the uteroplacental interface is the most discriminating independent MR variable in differentiating between normal placenta and IP. (orig.)

  15. Usefulness of magnetic resonance in the evaluation of perianal fistulas

    International Nuclear Information System (INIS)

    Campo, M.; Isusi, M.; Oleaga, L.; Grande, D.; Fernandez, G.; Tardaguila, F.

    2003-01-01

    Our aim was to confirm the usefulness of magnetic resonance in the evaluation of perianal fistulas, and in conjunction with a thought anatomical review of affected areas. This would allow for the building of a proper surgical plan, which would necessarily differ according to the fistula's complexity. We studied 75 patients with perianal fistulas and performed 81 MR studies by means of axial, sagittal and coronal T1 and T2 sequences. Fistula type, degree, etiology and correlation to surgical findings were all studied. Fifty-five patients underwent surgical treatment, and 26 underwent a more conservative treatment with MR follow-up. Ninety-nine fistulas were observed and classified according to norms set down by St. James University Hospital. Of the 55 cases submitted to surgery, 46 showed concordance between the surgical report and MR, whose sensitivity was 84%. In 9 patients, there was no correlation. In the study of perianal fistulas, it is important to establish both the fistulous tract and relationship to the sphincter complex. MR permits an identification of the sprinter complex and a more precise anatomical localization of the fistulous trajectory. It is also capable of differentiating between fibrosis and abscess. Therefore, MR is an appropriate technique for the study of perianal fistulas and related surgical planning. (Author) 6 refs

  16. Evaluation of mitral regurgitation by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Kishi, Naohiro; Kumai, Toshihiko

    1993-01-01

    Valvular regurgitation can be detected as a region of signal loss ('flow void') by cardiac cine magnetic resonance (MR) imaging. Cine MR images of 36 patients with mitral regurgitation caused by mitral valve prolapse (MVP) and non-MVP were evaluated and compared with color Doppler flow images. The direction, distance, area and timing of flow void were detected in all patients in several different planes at mitral level with a 0.5 Tesla superconducting magnet by an ECG-gated fast field echo technique. In 23 of the 36 patients contiguous multiple transaxial images were also obtained to calculate the volumes of flow void and the left atrium. The direction of flow void tended to deviate to the opposite side within the left atrium in MVP. The frame showing maximal area of flow void was demonstrated in mid-systole in 24 of the 36 patients (67%). The distance, area and volume of flow void were concordant with the grade from color Doppler flow images. The volumes of flow void and the left atrium correlated (n=19, r=0.74, p<0.05) in MVP. In conclusion, cine MR images in several different planes or contiguous multiple slices are useful in determining spatial orientation and the extent and timing of mitral regurgitation noninvasively. Furthermore, calculation of the volume of flow void enables the assessment of the semiquantitation of mitral regurgitation. (author)

  17. Rapid Evaluation of Platelet Function With T2 Magnetic Resonance

    Science.gov (United States)

    Cuker, Adam; Husseinzadeh, Holleh; Lebedeva, Tatiana; Marturano, Joseph E.; Massefski, Walter; Lowery, Thomas J.; Lambert, Michele P.; Abrams, Charles S.; Weisel, John W.

    2016-01-01

    Objectives: The clinical diagnosis of qualitative platelet disorders (QPDs) based on light transmission aggregometry (LTA) requires significant blood volume, time, and expertise, all of which can be barriers to utilization in some populations and settings. Our objective was to develop a more rapid assay of platelet function by measuring platelet-mediated clot contraction in small volumes (35 µL) of whole blood using T2 magnetic resonance (T2MR). Methods: We established normal ranges for platelet-mediated clot contraction using T2MR, used these ranges to study patients with known platelet dysfunction, and then evaluated agreement between T2MR and LTA with arachidonic acid, adenosine diphosphate, epinephrine, and thrombin receptor activator peptide. Results: Blood from 21 healthy donors was studied. T2MR showed 100% agreement with LTA with each of the four agonists and their cognate inhibitors tested. T2MR successfully detected abnormalities in each of seven patients with known QPDs, with the exception of one patient with a novel mutation leading to Hermansky-Pudlak syndrome. T2MR appeared to detect platelet function at similar or lower platelet counts than LTA. Conclusions: T2MR may provide a clinically useful approach to diagnose QPDs using small volumes of whole blood, while also providing new insight into platelet biology not evident using plasma-based platelet aggregation tests. PMID:28028118

  18. Evaluation of pituitary lesions on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sakurai, Takashi; Sakamoto, Tatsuo; Sekino, Hiroaki; Inada, Yoichi; Ishikawa, Toru; Sato, Mitsuya

    1994-01-01

    We evaluated the magnetic resonance imaging (MRI) of seventeen patients with pituitary adenomas (10 cases of prolactin secreting ; 2, growth hormone secreting and 5, non-functioning adenomas) and three patients with pituitary enlargement due to hypothyroidism. The volume of the functional adenomas or the enlarged pituitary glands correlated by MRI correlated with the level of serum pituitary hormone. We evaluated the points of differences on the T 1 weighted images of MRI between microadenomas and pituitary enlargements. The microadenomas appeared as the enlarged pituitary gland with isointensity area, but following administration of Gd-DTPA, the adenomas were recognized as a low intensity area (mass) with in an enhanced high intensity area of the normal gland with a shift of the pituitary stalk. On the other hand, the pituitary enlargements appeared as a large iso intensity area on T 1 weighted images, and were homogeneously enhanced as a high intensity area after Gd-DTPA administration, but without a shift of the pituitary stalk. Signal intensity ratios (SIR) and contrast enhancement ratios (CER) of all cases with pituitary adenomas were calculated using MRI. Differences in SIR and CER could not be demonstrated among the hormone-secreting adenomas. Thus, it is difficult to differentiate the various types of adenomas by using the differences in SIR or CER, since there are many, interfering factors, including hemorrhage, cyst, and necrosis. Postoperative permanent diabetes insipidus (DI) appeared in the cases that had no visualization of posterior high signal intensity area and a tumoral mass effect on the hypothalamus on preoperative MRI. The reason for postoperative permanent DI is thought to be the result of a disturbance of blood circulation in the pituitary gland due to a mass effect and surgical burden to the proximal pituitary stalk or the hypothalamus. (author)

  19. Effect of the resonant magnetic perturbation on the plasma parameters in COMPASS tokamak’s divertor region

    Science.gov (United States)

    Dimitrova, M.; Cahyna, P.; Peterka, M.; Hasan, E.; Popov, Tsv K.; Ivanova, P.; Vasileva, E.; Panek, R.; Cavalier, J.; Seidl, J.; Markovic, T.; Havlicek, J.; Dejarnac, R.; Weinzettl, V.; Hacek, P.; Tomes, M.; the COMPASS Team; the EUROfusion MST1 Team

    2018-02-01

    The resonant magnetic perturbation (RMP) has proven to be a useful way to suppress edge-localized modes that under certain conditions can damage the device by the large power fluxes carried from the bulk plasma to the wall. The effect of RMP on the L-mode plasma parameters in the divertor region of the COMPASS tokamak was studied using the array of 39 Langmuir probes embedded into the divertor target. The current-voltage (IV) probe characteristics were processed by the first-derivative probe technique to obtain the plasma potential and the electron energy distribution function (EEDF) which was approximated by a bi-Maxwellian EEDF with a low-energy (4-6 eV) fraction and a high-energy (11-35 eV) one, the both factions having similar electron density. Clear splitting was observed during the RMP pulse in the low-field-side scrape-off-layer profiles of the floating potential U fl and the ion saturation current density J sat; these two quantities were obtained both by direct continuous measurement and by evaluation of the IV characteristics of probes with swept bias. The negative peaks of U fl induced by RMP spatially overlaps with the local minima of J sat (and n e) rather than with its local maxima which is partly caused by the spatial variation of the plasma potential and partly by the changed shape of the EEDF. The effective temperature of the whole EEDF is not correlated with the negative peaks of U fl, and the profile of the parallel power flux density shows secondary maxima due to RMP which mimic those of J sat.

  20. Evaluation of some infiltration models and hydraulic parameters

    International Nuclear Information System (INIS)

    Haghighi, F.; Gorji, M.; Shorafa, M.; Sarmadian, F.; Mohammadi, M. H.

    2010-01-01

    The evaluation of infiltration characteristics and some parameters of infiltration models such as sorptivity and final steady infiltration rate in soils are important in agriculture. The aim of this study was to evaluate some of the most common models used to estimate final soil infiltration rate. The equality of final infiltration rate with saturated hydraulic conductivity (Ks) was also tested. Moreover, values of the estimated sorptivity from the Philips model were compared to estimates by selected pedotransfer functions (PTFs). The infiltration experiments used the doublering method on soils with two different land uses in the Taleghan watershed of Tehran province, Iran, from September to October, 2007. The infiltration models of Kostiakov-Lewis, Philip two-term and Horton were fitted to observed infiltration data. Some parameters of the models and the coefficient of determination goodness of fit were estimated using MATLAB software. The results showed that, based on comparing measured and model-estimated infiltration rate using root mean squared error (RMSE), Hortons model gave the best prediction of final infiltration rate in the experimental area. Laboratory measured Ks values gave significant differences and higher values than estimated final infiltration rates from the selected models. The estimated final infiltration rate was not equal to laboratory measured Ks values in the study area. Moreover, the estimated sorptivity factor by Philips model was significantly different to those estimated by selected PTFs. It is suggested that the applicability of PTFs is limited to specific, similar conditions. (Author) 37 refs.

  1. Multimethods approach to safety-parameter-display evaluation

    International Nuclear Information System (INIS)

    Banks, W.W.; Blackman, H.S.; Gertman, D.I.; Petersen, R.J.

    1982-01-01

    The Human Factors Engineering Office of EG and G Idaho performed this NRC-funded study to assist the NRC in objectively assessing licensee-developed safety parameter display (SPD) formats and designs. The purpose of this study was to quantitatively measure the degree to which a tachistoscopic method of display evaluation would correlate with the results of a multidimensional rating approach to display evaluation. Results of the following three experiments will be presented; (a) tachistoscopic, (b) multidimensional rating scale, and (c) the combined results of a and b. The test material for all experiments consisted of three multivariate data display formats all under development as SPDs for reactor control rooms presenting safety parameter display data at the loss-of-fluid test (LOFT) facility. The three display formats studied were stars, deviation bar graphs, and meters. Eighteen adult volunteers were used as subjects. All were currently qualified reactor operators from the LOFT reactor plant, with a mean of 9.4 years reactor operating experience

  2. Parameters of Instrumental Swallowing Evaluations: Describing a Diagnostic Dilemma.

    Science.gov (United States)

    Pisegna, Jessica M; Langmore, Susan E

    2016-06-01

    The aim of this study was to compare selected parameters of two swallow evaluations: fiberoptic endoscopic evaluation of swallowing (FEES) and the modified barium swallow (MBS) study. This was a cross-sectional, descriptive study. Fifty-five clinicians were asked to watch video recordings of swallow evaluations of 2 patients that were done using fluoroscopy and endoscopy simultaneously. In a randomized order, clinicians viewed 4 edited videos from simultaneous evaluations: the FEES and MBS videos of patient 1 and 2 each taking one swallow of 5 mL applesauce. Clinicians filled out a questionnaire that asked (1) which anatomical sites they could visualize on each video, (2) where they saw pharyngeal residue after a swallow, (3) their overall clinical impression of the pharyngeal residue, and (4) their opinions of the evaluation styles. Clinicians reported a significant difference in the visualization of anatomical sites, 11 of the 15 sites were reported as better-visualized on the FEES than on the MBS video (p < 0.05). Clinicians also rated residue to be present in more locations on the FEES than on the MBS. Clinicians' overall impressions of the severity of residue on the same exact swallow were significantly different depending on the evaluation type (FEES vs. MBS for patient 1 χ(2) = 20.05, p < 0.0001; patient 2 χ(2) = 7.52, p = 0.006), with FEES videos rated more severely. FEES advantages were: more visualization of pharyngeal and laryngeal swallowing anatomy and residue. However, as a result, clinicians provided more severe impressions of residue amount on FEES. On one hand, this suggests that FEES is a more sensitive tool than MBS studies, but on the other hand, clinicians might provide more severe interpretations on FEES.

  3. Magnetic resonance imaging in the evaluation of standard radiotherapy field borders in patients with uterine cervix cancer

    International Nuclear Information System (INIS)

    Freire, Geison Moreira; Dias, Rodrigo Souza; Giordani, Adelmo Jose; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo; Ribalta, Julisa Chamorro Lascasas

    2010-01-01

    Objective: to evaluate, by means of magnetic resonance imaging, the standardized field borders in radiotherapy for malignant neoplasm of uterine cervix, and to determine the role of this method in the reduction of possible planning errors related to the conventional technique. Materials and methods: magnetic resonance imaging studies for planning of treatment of 51 patients with uterine cervix cancer were retrospectively analyzed. The parameters assessed were the anterior and posterior field borders on sagittal section. Results: The anterior field border was inappropriate in 20 (39.2%) patients and geographic miss was observed in 37.3% of cases in the posterior border. The inappropriateness of both field borders did not correlate with clinical parameters such as patients' age, tumor staging, histological type and degree. Conclusion: the evaluation of standardized field borders with the use of magnetic resonance imaging has demonstrated high indices of inappropriateness of the lateral field borders, as well as the relevant role of magnetic resonance imaging in the radiotherapy planning for patients with uterine cervix cancer with a view to reduce the occurrence of geographic miss of the target volume. (author)

  4. Calculation of quasi-stationary states parameters within the algebraic version of the resonating group method

    International Nuclear Information System (INIS)

    Okhrimenko, I.P.

    1984-01-01

    The dynamical equations of the algebraic version of the resonating group method are used to determine the positions and the widths of quasi-stationary states or to find the poles of the S-matrix in the fourth quadrant of the K-plane. Concrete calculations are performed by the example of an α-decay of 8 Be. A comparison with the results of the other authors and experiment is made

  5. Mechanical design parameters for detection of nuclear signals by magnetic resonance force microscopy

    International Nuclear Information System (INIS)

    Moore, G.J.; Hanlon, J.A.; Lamartine, B.; Hawley, M.; Solem, J.C.; Signer, S.; Jarmer, J.J.; Penttila, S.; Sillerud, L.O.; Pryputniewicz, R.J.

    1993-01-01

    Recent theoretical work has shown that mechanical detection of magnetic resonance from a single nuclear spin is in principle possible. This theory has recently been experimentally validated by the mechanical detection of electron spin resonance signals using microscale cantilevers. Currently we are extending this technology in an attempt to detect nuclear signals which are extending this technology in an attempt to detect nuclear signals which are three orders of magnitude lower in intensity than electron signals. In order to achieve the needed thousand-fold improvement in sensitivity we have undertaken the development of optimized mechanical cantilevers and highly polarized samples. Finite element modeling is used as a tool to simulate cantilever beam dynamics and to optimize the mechanical properties including Q, resonant frequency, amplitude of vibration and spring constant. Simulations are compared to experiments using heterodyne hologram interferometry. Nanofabrication of optimized cantilevers via ion milling will be directed by the outcome of these simulations and experiments. Highly polarized samples are developed using a three-fold approach: (1) high magnetic field strength (2.5T), (2) low temperature (1K), and (3) use of samples polarized by dynamic nuclear polarization. Our recent experiments have demonstrated nuclear polarizations in excess of 50% in molecules of toulene

  6. Evaluated 182,183,184,186W Neutron Cross Sections and Covariances in the Resolved Resonance Region

    International Nuclear Information System (INIS)

    Pigni, Marco T; Leal, Luiz C

    2015-01-01

    Oak Ridge National Laboratory (ORNL) has recently completed the resonance parameter evaluation of four tungsten isotopes, i.e., 182,183,184,186 W, in the neutron energy range of thermal up to several keV. This nuclear data work was performed with support from the US Nuclear Criticality Safety Program (NCSP) in an effort to provide improved tungsten cross section and covariance data for criticality safety analyses. The evaluation methodology uses the Reich-Moore approximation of the R-matrix formalism of the code SAMMY to fit high-resolution measurements performed in 2010 and 2012 at the Geel linear accelerator facility (GELINA), as well as other experimental data sets on natural tungsten available in the EXFOR library. In the analyzed energy range, this work nearly doubles the resolved resonance region (RRR) present in the latest US nuclear data library ENDF/B-VII.1. In view of the interest in tungsten for distinct types of nuclear applications and the relatively homogeneous distribution of the isotopic tungsten - namely, 182 W(26.5%), 183 W(14.31%), 184 W(30.64%), and 186 W(28.43%) - the completion of these four evaluations represents a significant contribution to the improvement of the ENDF library. This paper presents an overview of the evaluated resonance parameters and related covariances for total and capture cross sections on the four tungsten isotopes.

  7. Evaluation of the perceptual grouping parameter in the CTVA model

    Directory of Open Access Journals (Sweden)

    Manuel Cortijo

    2005-01-01

    Full Text Available The CODE Theory of Visual Attention (CTVA is a mathematical model explaining the effects of grouping by proximity and distance upon reaction times and accuracy of response with regard to elements in the visual display. The predictions of the theory agree quite acceptably in one and two dimensions (CTVA-2D with the experimental results (reaction times and accuracy of response. The difference between reaction-times for the compatible and incompatible responses, known as the responsecompatibility effect, is also acceptably predicted, except at small distances and high number of distractors. Further results using the same paradigm at even smaller distances have been now obtained, showing greater discrepancies. Then, we have introduced a method to evaluate the strength of sensory evidence (eta parameter, which takes grouping by similarity into account and minimizes these discrepancies.

  8. Order parameters in lanthanum gallate lightly doped with manganese and paramagnetic resonance

    Science.gov (United States)

    Vazhenin, V. A.; Potapov, A. P.; Artyomov, M. Yu.; Guseva, V. B.

    2010-09-01

    The Cr3+ centers have been revealed, transitions at room temperature have been identified, and spin Hamiltonian parameters have been determined for the Cr3+ and Fe3+ triclinic centers in lanthanum gallate lightly doped with manganese. The principal axes of the fourth-rank fine-structure tensor for the Fe3+ triclinic centers have been established and used to determine the order parameters, i.e., the angles of rotation of oxygen octahedra of lanthanum gallate with respect to the perovskite structure. The order parameter in the rhombohedral phase has been estimated.

  9. Neutron Transmission and Capture Measurements and Resonance Parameter Analysis of Neodymium from 1eV to 500 eV

    International Nuclear Information System (INIS)

    DP Barry; MJ Trbovich; Y Danon; RC Block; RE Slovacek

    2005-01-01

    Neodymium is a 235 U fission product and is important for reactor neutronic calculations. The aim of the present work is to improve upon the existing neutron cross section data of neodymium. Neutron capture and transmission measurements were performed by the time-off-light technique at the Rensselaer Polytechnic Institute LINAC laboratory using metallic neodymium samples. The capture measurements were made at the 25-m flight station with a 16-segment NaI multiplicity detector, and the transmission measurements were performed at 15-m and 25-m flight stations, respectively, with 6 Li glass scintillation detectors. After the data were collected and reduced, resonance parameters were determined by combined fitting of the transmission and capture data with the multilevel R-matrix Bayesian code SAMMY. The resonance parameters for all naturally occurring neodymium isotopes were deduced within the energy range of 1 eV to 500 eV. The resulting resonance parameters were used to calculate the capture resonance integrals from this energy. The RPI parameters gave a resonance integral value of 32 ± 1 barns that is approximately 7% lower than that obtained with the ENDF-B/VI parameters. The current measurements significantly reduce the uncertainties on the resonance parameters when compared with previously published parameters

  10. Evaluation of handwriting movement kinematics: from an ecological to a magnetic resonance environment

    Directory of Open Access Journals (Sweden)

    Ambra Bisio

    2016-09-01

    Full Text Available Writing is a means of communication which requires complex motor, perceptual and cognitive skills. If one of these abilities gets lost following traumatic events or due to neurological diseases, handwriting could deteriorate. Occupational therapy practitioners provide rehabilitation services for people with impaired handwriting. However, to determine the effectiveness of handwriting interventions no studies assessed whether the proposed treatments improved the kinematics of writing movement or had an effect at the level of the central nervous system. There is need to find new quantitative methodologies able to describe the behavioral and the neural outcomes of the rehabilitative interventions for handwriting. In the present study we proposed a combined approach that allowed evaluating the kinematic parameters of handwriting movements, acquired by means of a magnetic resonance-compatible tablet, and their neural correlates obtained simultaneously from a functional magnetic resonance imaging (fMRI examination. Results showed that the system was reliable in term of reproducibility of the kinematic data during a test/re-test procedure. Further, despite the modifications with respect to an ecological writing movement condition, the kinematic parameters acquired inside the MR-environment were descriptive of individuals’ movement features. At last, the imaging protocol succeeded to show the activation of the cerebral regions associated with the production of writing movement in healthy people. From these findings, this methodology seems to be promising to evaluate the handwriting movement deficits and the potential alterations in the neural activity in those individuals who have handwriting difficulties. Finally, it would provide a mean to quantitatively assess the effect of a rehabilitative treatment.

  11. Evaluation of Handwriting Movement Kinematics: From an Ecological to a Magnetic Resonance Environment

    Science.gov (United States)

    Bisio, Ambra; Pedullà, Ludovico; Bonzano, Laura; Ruggeri, Piero; Brichetto, Giampaolo; Bove, Marco

    2016-01-01

    Writing is a means of communication which requires complex motor, perceptual, and cognitive skills. If one of these abilities gets lost following traumatic events or due to neurological diseases, handwriting could deteriorate. Occupational therapy practitioners provide rehabilitation services for people with impaired handwriting. However, to determine the effectiveness of handwriting interventions no studies assessed whether the proposed treatments improved the kinematics of writing movement or had an effect at the level of the central nervous system. There is need to find new quantitative methodologies able to describe the behavioral and the neural outcomes of the rehabilitative interventions for handwriting. In the present study we proposed a combined approach that allowed evaluating the kinematic parameters of handwriting movements, acquired by means of a magnetic resonance-compatible tablet, and their neural correlates obtained simultaneously from a functional magnetic resonance imaging examination. Results showed that the system was reliable in term of reproducibility of the kinematic data during a test/re-test procedure. Further, despite the modifications with respect to an ecological writing movement condition, the kinematic parameters acquired inside the MR-environment were descriptive of individuals’ movement features. At last, the imaging protocol succeeded to show the activation of the cerebral regions associated with the production of writing movement in healthy people. From these findings, this methodology seems to be promising to evaluate the handwriting movement deficits and the potential alterations in the neural activity in those individuals who have handwriting difficulties. Finally, it would provide a mean to quantitatively assess the effect of a rehabilitative treatment. PMID:27746727

  12. Atlas of neutron resonances

    CERN Document Server

    Mughabghab, Said

    2018-01-01

    Atlas of Neutron Resonances: Resonance Properties and Thermal Cross Sections Z= 1-60, Sixth Edition, contains an extensive list of detailed individual neutron resonance parameters for Z=1-60, as well as thermal cross sections, capture resonance integrals, average resonance parameters and a short survey of the physics of thermal and resonance neutrons. The long introduction contains: nuclear physics formulas aimed at neutron physicists; topics of special interest such as valence neutron capture, nuclear level density parameters, and s-, p-, and d-wave neutron strength functions; and various comparisons of measured quantities with the predictions of nuclear models, such as the optical model. As in the last edition, additional features have been added to appeal to a wider spectrum of users. These include: spin-dependent scattering lengths that are of interest to solid-state physicists, nuclear physicists and neutron evaluators; calculated and measured Maxwellian average 5-keV and 30-keV capture cross sections o...

  13. Contrast-enhanced magnetic resonance imaging of the breast: the value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in classifying lesions

    International Nuclear Information System (INIS)

    Veltman, J.; Stoutjesdijk, M.; Mann, R.; Huisman, H.J.; Barentsz, J.O.; Blickman, J.G.; Boetes, C.

    2008-01-01

    The value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in characterizing breast lesions on magnetic resonance imaging (MRI) was evaluated. Sixty-eight malignant and 34 benign lesions were included. In the scanning protocol, high temporal resolution imaging was combined with high spatial resolution imaging. The high temporal resolution images were recorded every 4.1 s during initial enhancement (fast dynamic analysis). The high spatial resolution images were recorded at a temporal resolution of 86 s (slow dynamic analysis). In the fast dynamic evaluation pharmacokinetic parameters (K trans , V e and k ep ) were evaluated. In the slow dynamic analysis, each lesion was scored according to the BI-RADS classification. Two readers evaluated all data prospectively. ROC and multivariate analysis were performed. The slow dynamic analysis resulted in an AUC of 0.85 and 0.83, respectively. The fast dynamic analysis resulted in an AUC of 0.83 in both readers. The combination of both the slow and fast dynamic analyses resulted in a significant improvement of diagnostic performance with an AUC of 0.93 and 0.90 (P = 0.02). The increased diagnostic performance found when combining both methods demonstrates the additional value of our method in further improving the diagnostic performance of breast MRI. (orig.)

  14. Using 3 Tesla magnetic resonance imaging in the pre-operative evaluation of tongue carcinoma.

    Science.gov (United States)

    Moreno, K F; Cornelius, R S; Lucas, F V; Meinzen-Derr, J; Patil, Y J

    2017-09-01

    This study aimed to evaluate the role of 3 Tesla magnetic resonance imaging in predicting tongue tumour thickness via direct and reconstructed measures, and their correlations with corresponding histological measures, nodal metastasis and extracapsular spread. A prospective study was conducted of 25 patients with histologically proven squamous cell carcinoma of the tongue and pre-operative 3 Tesla magnetic resonance imaging from 2009 to 2012. Correlations between 3 Tesla magnetic resonance imaging and histological measures of tongue tumour thickness were assessed using the Pearson correlation coefficient: r values were 0.84 (p Tesla magnetic resonance imaging had 83 per cent sensitivity, 82 per cent specificity, 82 per cent accuracy and a 90 per cent negative predictive value for detecting cervical lymph node metastasis. In this cohort, 3 Tesla magnetic resonance imaging measures of tumour thickness correlated highly with the corresponding histological measures. Further, 3 Tesla magnetic resonance imaging was an effective method of detecting malignant adenopathy with extracapsular spread.

  15. Relativistic effects in the intermolecular interaction-induced nuclear magnetic resonance parameters of xenon dimer

    DEFF Research Database (Denmark)

    Hanni, Matti; Lantto, Perttu; Ilias, Miroslav

    2007-01-01

    Relativistic effects on the 129Xe nuclear magnetic resonance shielding and 131Xe nuclear quadrupole coupling (NQC) tensors are examined in the weakly bound Xe2 system at different levels of theory including the relativistic four-component Dirac-Hartree-Fock (DHF) method. The intermolecular...... interaction-induced binary chemical shift d, the anisotropy of the shielding tensor ?s, and the NQC constant along the internuclear axis ?ll are calculated as a function of the internuclear distance. DHF shielding calculations are carried out using gauge-including atomic orbitals. For comparison, the full...... is obtained for d and ?s in Xe2. For these properties, the currently most complete theoretical description is obtained by a piecewise approximation where the uncorrelated relativistic DHF results obtained close to the basis-set limit are corrected, on the one hand, for NR correlation effects and, on the other...

  16. Evaluation of magnetic resonance velocimetry for steady flow.

    Science.gov (United States)

    Ku, D N; Biancheri, C L; Pettigrew, R I; Peifer, J W; Markou, C P; Engels, H

    1990-11-01

    Whole body magnetic resonance (MR) imaging has recently become an important diagnostic tool for cardiovascular diseases. The technique of magnetic resonance phase velocity encoding allows the quantitative measurement of velocity for an arbitrary component direction. A study was initiated to determine the ability and accuracy of MR velocimetry to measure a wide range of flow conditions including flow separation, three-dimensional secondary flow, high velocity gradients, and turbulence. A steady flow system pumped water doped with manganese chloride through a variety of test sections. Images were produced using gradient echo sequences on test sections including a straight tube, a curved tube, a smoothly converging-diverging nozzle, and an orifice. Magnetic resonance measurements of laminar and turbulent flows were depicted as cross-sectional velocity profiles. MR velocity measurements revealed such flow behavior as spatially varying velocity, recirculation and secondary flows over a wide range of conditions. Comparisons made with published experimental laser Doppler anemometry measurements and theoretical calculations for similar flow conditions revealed excellent accuracy and precision levels. The successful measurement of velocity profiles for a variety of flow conditions and geometries indicate that magnetic resonance imaging is an accurate, non-contacting velocimeter.

  17. Evaluation of left ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Thomsen, C; Mehlsen, J

    1986-01-01

    Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared...

  18. Cardiac Magnetic Resonance Imaging in Myocarditis Reveals Persistent Disease Activity Despite Normalization of Cardiac Enzymes and Inflammatory Parameters at 3-Month Follow-Up.

    Science.gov (United States)

    Berg, Jan; Kottwitz, Jan; Baltensperger, Nora; Kissel, Christine K; Lovrinovic, Marina; Mehra, Tarun; Scherff, Frank; Schmied, Christian; Templin, Christian; Lüscher, Thomas F; Heidecker, Bettina; Manka, Robert

    2017-11-01

    There is a major unmet need to identify high-risk patients in myocarditis. Although decreasing cardiac and inflammatory markers are commonly interpreted as resolving myocarditis, this assumption has not been confirmed as of today. We sought to evaluate whether routine laboratory parameters at diagnosis predict dynamic of late gadolinium enhancement (LGE) as persistent LGE has been shown to be a risk marker in myocarditis. Myocarditis was diagnosed based on clinical presentation, high-sensitivity troponin T, and cardiac magnetic resonance imaging, after exclusion of obstructive coronary artery disease by angiography. Cardiac magnetic resonance imaging was repeated at 3 months. LGE extent was analyzed with the software GT Volume. Change in LGE >20% was considered significant. Investigated cardiac and inflammatory markers included high-sensitivity troponin T, creatine kinase, myoglobin, N-terminal B-type natriuretic peptide, C-reactive protein, and leukocyte count. Twenty-four patients were enrolled. Absolute levels of cardiac enzymes and inflammatory markers at baseline did not predict change in LGE at 3 months. Cardiac and inflammatory markers had normalized in 21 patients (88%). LGE significantly improved in 16 patients (67%); however, it persisted to a lesser degree in 17 of them (71%) and increased in a small percentage (21%) despite normalization of cardiac enzymes. This is the first study reporting that cardiac enzymes and inflammatory parameters do not sufficiently reflect LGE in myocarditis. Although a majority of patients with normalizing laboratory markers experienced improved LGE, in a small percentage LGE worsened. These data suggest that cardiac magnetic resonance imaging might add value to currently existing diagnostic tools for risk assessment in myocarditis. © 2017 American Heart Association, Inc.

  19. Comparison of morphological and kinetic parameters in distinction of benign and malignant breast lesions in dynamic contrast enhanced magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Direnç Özlem Aksoy

    2013-12-01

    Full Text Available Objective: To evaluate the value of qualitative morphologicaland kinetic data and quantitative kinetic data indistinction of malignancy in dynamic contrast enhancedmagnetic resonance imaging (DCE-MRI of the breast.Methods: DCE-MRIs of 49 subjects were evaluated.Morphological and contrast enhancement parameters of95 lesions were recorded in these subjects. Post-contrastkinetic behavior of these lesions were also investigated.Among the quantitative parameters, relative enhancements(E1, E2, Epeak, time-to-peak (Tpeak, slope ofcurve (Slope, signal enhancement ratio (SER, and maximumintensity time ratio (MITR were calculated. Theseresults were compared with the pathological diagnosis.Results: Spiculated contour (100%, rim enhancement(97.87%, irregular shape (95.74%, and irregular margin(91.49% were the most specific morphological featuresof malignancy in mass lesions. In non-mass lesions, focalzone (91.49% was the most specific feature of malignancy.74.5% of the benign lesions showed type 1, 77.1%of the malignant lesions showed type 2 and 3 curves accordingto the kinetic curve evaluation. All quantitativeparameters except Epeak were found to be statisticallysignificant in distinction of malignancy.Conclusion: None of the morphological features of thebenign lesions were found to be significantly specific.More specific features can be described for malignantlesions. Early behavior of the kinetic curve is not usefulfor diagnosis of malignancy but the intermediate and latebehavior gives useful information. Quantitative data involvedin this study might be promising.Key words: Morphological, kinetic, breast lesions, magnetic resonance imaging, dynamic

  20. Evaluation of Critical Parameters to Improve Slope Drainage System

    Directory of Open Access Journals (Sweden)

    Yong Weng Long

    2017-01-01

    Full Text Available This study focuses on identifying and evaluating critical parameters of various drainage configurations, arrangement, and filter which affect the efficiency of water draining system in slopes. There are a total of seven experiments with different types of homogeneous soil, drainage envelope, filter material, and quantity of pipes performed utilizing a model box with a dimension of 0.8 m × 0.8 m × 0.6 m. The pipes were orientated at 5 degrees from the horizontal. Rainfall event was introduced via a rainfall simulator with rainfall intensity of 434.1 mm/h. From the experiments performed, the expected outcomes when utilizing double pipes and geotextile as envelope filter were verified in this study. The results obtained from these experiments were reviewed and compared with Chapter 14 “Subsurface Drainage Systems” of DID’s Irrigation and Agricultural Drainage Manual of Malaysia and the European standard. It is recommended that the pipe installed in the slope could be wrapped with geotextile and in tandem with application of granular filter to minimize clogging without affecting the water discharge rate. Terzaghi’s filter criteria could be followed closely when deciding on new materials to act as aggregate filter. A caging system could be introduced as it could maintain the integrity of the drainage system and could ease installation.

  1. Evaluating the parameters of a mobile maize dryer in practice

    Directory of Open Access Journals (Sweden)

    Josef Los

    2013-01-01

    Full Text Available The method of drying maize for grain has been recently employed on a large scale in the Czech Republic not only thanks to new maize hybrids but also thanks to the existence of new models of drying plants. One of the new post-harvest lines is a plant in Lipoltice (mobile dryer installed in 2010, storage base in 2012 where basic operational measurements were made of the energy intensiveness of drying and operating parameters of the maize dryer were evaluated. The process of maize drying had two stages, i.e. pre-drying from the initial average grain humidity of 28.55% to 19.6% in the first stage, and the additional drying from 16.7% to a final storage grain humidity of 13.7%. Mean volumes of natural gas consumed per 1 t% for drying in the first and second stage amounted to 1.275 m3 and 1.56 m3, respectively. The total mean consumption of electric energy per 1 t% was calculated to be 1.372 kWh for the given configuration of the post-harvest line.

  2. Harvesting rockfall hazard evaluation parameters from Google Earth Street View

    Science.gov (United States)

    Partsinevelos, Panagiotis; Agioutantis, Zacharias; Tripolitsiotis, Achilles; Steiakakis, Chrysanthos; Mertikas, Stelios

    2015-04-01

    Rockfall incidents along highways and railways prove extremely dangerous for properties, infrastructures and human lives. Several qualitative metrics such as the Rockfall Hazard Rating System (RHRS) and the Colorado Rockfall Hazard Rating System (CRHRS) have been established to estimate rockfall potential and provide risk maps in order to control and monitor rockfall incidents. The implementation of such metrics for efficient and reliable risk modeling require accurate knowledge of multi-parametric attributes such as the geological, geotechnical, topographic parameters of the study area. The Missouri Rockfall Hazard Rating System (MORH RS) identifies the most potentially problematic areas using digital video logging for the determination of parameters like slope height and angle, face irregularities, etc. This study aims to harvest in a semi-automated approach geometric and qualitative measures through open source platforms that may provide 3-dimensional views of the areas of interest. More specifically, the Street View platform from Google Maps, is hereby used to provide essential information that can be used towards 3-dimensional reconstruction of slopes along highways. The potential of image capturing along a programmable virtual route to provide the input data for photogrammetric processing is also evaluated. Moreover, qualitative characterization of the geological and geotechnical status, based on the Street View images, is performed. These attributes are then integrated to deliver a GIS-based rockfall hazard map. The 3-dimensional models are compared to actual photogrammetric measures in a rockfall prone area in Crete, Greece while in-situ geotechnical characterization is also used to compare and validate the hazard risk. This work is considered as the first step towards the exploitation of open source platforms to improve road safety and the development of an operational system where authorized agencies (i.e., civil protection) will be able to acquire near

  3. FDMXPC, ENDF/B Processing, with Reich-Moore and Adler-Adler Resonance Parameter Calculation

    International Nuclear Information System (INIS)

    Vertes, P.

    1995-01-01

    1 - Description of program or function: FDMXPC is a PC program to process evaluated data files in ENDF format. It computes transmission, self-indication and lumped average cross-section functionals for mixtures of isotopes

  4. Evaluation of support loss in micro-beam resonators: A revisit

    Science.gov (United States)

    Chen, S. Y.; Liu, J. Z.; Guo, F. L.

    2017-12-01

    This paper presents an analytical study on evaluation of support loss in micromechanical resonators undergoing in-plane flexural vibrations. Two-dimensional elastic wave theory is used to determine the energy transmission from the vibrating resonator to the support. Fourier transform and Green's function technique are adopted to solve the problem of wave motions on the surface of the support excited by the forces transmitted by the resonator onto the support. Analytical expressions of support loss in terms of quality factor, taking into account distributed normal stress and shear stress in the attachment region, and coupling between the normal stress and shear stress as well as material disparity between the support and the resonator, have been derived. Effects of geometry of micro-beam resonators, and material dissimilarity between support and resonator on support loss are examined. Numerical results show that 'harder resonator' and 'softer support' combination leads to larger support loss. In addition, the Perfectly Matched Layer (PML) numerical simulation technique is employed for validation of the proposed analytical model. Comparing with results of quality factor obtained by PML technique, we find that the present model agrees well with the results of PML technique and the pure-shear model overestimates support loss noticeably, especially for resonators with small aspect ratio and large material dissimilarity between the support and resonator.

  5. Stack Parameters Effect on the Performance of Anharmonic Resonator Thermoacoustic Heat Engine

    KAUST Repository

    Nouh, Mostafa A.

    2014-01-01

    A thermoacoustic heat engine (TAHE) converts heat into acoustic power with no moving parts. It exhibits several advantages over traditional engines, such as simple design, stable functionality, and environment-friendly working gas. In order to further improve the performance of TAHE, stack parameters need to be optimized. Stack\\'s position, length and plate spacing are the three main parameters that have been investigated in this study. Stack\\'s position dictates both the efficiency and the maximum produced acoustic power of the heat engine. Positioning the stack closer to the pressure anti-node might ensure high efficiency on the expense of the maximum produced acoustic power. It is noticed that the TAHE efficiency can further be improved by spacing the plates of the stack at a value of 2.4 of the thermal penetration depth, δk . Changes in the stack length will not affect the efficiency much as long as the temperature gradient across the stack, as a ratio of the critical temperature gradient ψ is more than 1. Upon interpreting the effect of these variations, attempts are made towards reaching the engine\\'s most powerful operating point.

  6. Stack Parameters Effect on the Performance of Anharmonic Resonator Thermoacoustic Heat Engine

    KAUST Repository

    Nouh, Mostafa A.; Arafa, Nadim M.; Abdel-Rahman, Ehab

    2014-01-01

    A thermoacoustic heat engine (TAHE) converts heat into acoustic power with no moving parts. It exhibits several advantages over traditional engines, such as simple design, stable functionality, and environment-friendly working gas. In order to further improve the performance of TAHE, stack parameters need to be optimized. Stack's position, length and plate spacing are the three main parameters that have been investigated in this study. Stack's position dictates both the efficiency and the maximum produced acoustic power of the heat engine. Positioning the stack closer to the pressure anti-node might ensure high efficiency on the expense of the maximum produced acoustic power. It is noticed that the TAHE efficiency can further be improved by spacing the plates of the stack at a value of 2.4 of the thermal penetration depth, δk . Changes in the stack length will not affect the efficiency much as long as the temperature gradient across the stack, as a ratio of the critical temperature gradient ψ is more than 1. Upon interpreting the effect of these variations, attempts are made towards reaching the engine's most powerful operating point.

  7. Anomalous solute transport in saturated porous media: Relating transport model parameters to electrical and nuclear magnetic resonance properties

    Science.gov (United States)

    Swanson, Ryan D; Binley, Andrew; Keating, Kristina; France, Samantha; Osterman, Gordon; Day-Lewis, Frederick D.; Singha, Kamini

    2015-01-01

    The advection-dispersion equation (ADE) fails to describe commonly observed non-Fickian solute transport in saturated porous media, necessitating the use of other models such as the dual-domain mass-transfer (DDMT) model. DDMT model parameters are commonly calibrated via curve fitting, providing little insight into the relation between effective parameters and physical properties of the medium. There is a clear need for material characterization techniques that can provide insight into the geometry and connectedness of pore spaces related to transport model parameters. Here, we consider proton nuclear magnetic resonance (NMR), direct-current (DC) resistivity, and complex conductivity (CC) measurements for this purpose, and assess these methods using glass beads as a control and two different samples of the zeolite clinoptilolite, a material that demonstrates non-Fickian transport due to intragranular porosity. We estimate DDMT parameters via calibration of a transport model to column-scale solute tracer tests, and compare NMR, DC resistivity, CC results, which reveal that grain size alone does not control transport properties and measured geophysical parameters; rather, volume and arrangement of the pore space play important roles. NMR cannot provide estimates of more-mobile and less-mobile pore volumes in the absence of tracer tests because these estimates depend critically on the selection of a material-dependent and flow-dependent cutoff time. Increased electrical connectedness from DC resistivity measurements are associated with greater mobile pore space determined from transport model calibration. CC was hypothesized to be related to length scales of mass transfer, but the CC response is unrelated to DDMT.

  8. Magnetic resonance imaging textural evaluation of posterior cranial fossa tumors in childhood; Avaliacao textural por ressonancia magnetica dos tumores da fossa posterior em criancas

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joelson Alves dos; Costa, Maria Olivia Rodrigues da; Otaduy, Maria Concepcion Garcia; Lacerda, Maria Teresa Carvalho de; Leite, Claudia da Costa [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia]. E-mail: joelson_alves@ig.com.br; Matsushita, Hamilton [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2004-08-01

    Objective: To distinguish healthy from pathological tissues in pediatric patients with posterior cranial fossa tumors using calculated textural parameters from magnetic resonance images. Materials And Methods: We evaluated 14 pediatric patients with posterior cranial fossa tumors using the software MaZda to define the texture parameters in selected regions of interest representing healthy and pathological tissues based on T2-weighted magnetic resonance images. Results: There was a statistically significant difference between normal and tumoral tissues as well as between supposedly normal tissues adjacent and distant from the tumoral lesion. Conclusion: Magnetic resonance textural evaluation is an useful tool for determining differences among various tissues, including tissues that appear apparently normal on visual analysis. (author)

  9. FANAC - a shape analysis program for resonance parameter extraction from neutron capture data for light and medium-weight nuclei

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1977-11-01

    A least-squares shape analysis program is described which is used at the Karlsruhe Nuclear Research Center for the extraction of resonance parameters from high-resolution capture data. The FORTRAN program was written for light to medium-weight or near-magic target nuclei whose cross sections are characterized on one hand by broad s-wave levels with negligible Doppler broadening but pronounced multi-level interference, on the other hand by narrow p-, d- ... wave resonances with negligible multi-level interference but pronounced Doppler broadening. Accordingly the Reich-Moore multi-level formalism without Doppler broadening is used for s-wave levels, and a single-level description with Doppler braodening for p-, d- ... wave levels. Calculated capture yields are resolution broadened. Multiple-collision events are simulated by Monte Carlo techniques. Up to five different time-of-flight capture data sets can be fitted simultaneously for samples containing up to ten isotopes. Input and output examples are given and a FORTRAN list is appended. (orig.)

  10. Relativistic effects in the intermolecular interaction-induced nuclear magnetic resonance parameters of xenon dimer.

    Science.gov (United States)

    Hanni, Matti; Lantto, Perttu; Ilias, Miroslav; Jensen, Hans Jorgen Aagaard; Vaara, Juha

    2007-10-28

    Relativistic effects on the (129)Xe nuclear magnetic resonance shielding and (131)Xe nuclear quadrupole coupling (NQC) tensors are examined in the weakly bound Xe(2) system at different levels of theory including the relativistic four-component Dirac-Hartree-Fock (DHF) method. The intermolecular interaction-induced binary chemical shift delta, the anisotropy of the shielding tensor Deltasigma, and the NQC constant along the internuclear axis chi( parallel) are calculated as a function of the internuclear distance. DHF shielding calculations are carried out using gauge-including atomic orbitals. For comparison, the full leading-order one-electron Breit-Pauli perturbation theory (BPPT) is applied using a common gauge origin. Electron correlation effects are studied at the nonrelativistic (NR) coupled-cluster singles and doubles with perturbational triples [CCSD(T)] level of theory. The fully relativistic second-order Moller-Plesset many-body perturbation (DMP2) theory is used to examine the cross coupling between correlation and relativity on NQC. The same is investigated for delta and Deltasigma by BPPT with a density functional theory model. A semiquantitative agreement between the BPPT and DHF binary property curves is obtained for delta and Deltasigma in Xe(2). For these properties, the currently most complete theoretical description is obtained by a piecewise approximation where the uncorrelated relativistic DHF results obtained close to the basis-set limit are corrected, on the one hand, for NR correlation effects and, on the other hand, for the BPPT-based cross coupling of relativity and correlation. For chi( parallel), the fully relativistic DMP2 results obtain a correction for NR correlation effects beyond MP2. The computed temperature dependence of the second virial coefficient of the (129)Xe nuclear shielding is compared to experiment in Xe gas. Our best results, obtained with the piecewise approximation for the binary chemical shift combined with the

  11. Resonance self-shielding effect in uncertainty quantification of fission reactor neutronics parameters

    International Nuclear Information System (INIS)

    Chiba, Go; Tsuji, Masashi; Narabayashi, Tadashi

    2014-01-01

    In order to properly quantify fission reactor neutronics parameter uncertainties, we have to use covariance data and sensitivity profiles consistently. In the present paper, we establish two consistent methodologies for uncertainty quantification: a self-shielded cross section-based consistent methodology and an infinitely-diluted cross section-based consistent methodology. With these methodologies and the covariance data of uranium-238 nuclear data given in JENDL-3.3, we quantify uncertainties of infinite neutron multiplication factors of light water reactor and fast reactor fuel cells. While an inconsistent methodology gives results which depend on the energy group structure of neutron flux and neutron-nuclide reaction cross section representation, both the consistent methodologies give fair results with no such dependences.

  12. RESONANCE SELF-SHIELDING EFFECT IN UNCERTAINTY QUANTIFICATION OF FISSION REACTOR NEUTRONICS PARAMETERS

    Directory of Open Access Journals (Sweden)

    GO CHIBA

    2014-06-01

    Full Text Available In order to properly quantify fission reactor neutronics parameter uncertainties, we have to use covariance data and sensitivity profiles consistently. In the present paper, we establish two consistent methodologies for uncertainty quantification: a self-shielded cross section-based consistent methodology and an infinitely-diluted cross section-based consistent methodology. With these methodologies and the covariance data of uranium-238 nuclear data given in JENDL-3.3, we quantify uncertainties of infinite neutron multiplication factors of light water reactor and fast reactor fuel cells. While an inconsistent methodology gives results which depend on the energy group structure of neutron flux and neutron-nuclide reaction cross section representation, both the consistent methodologies give fair results with no such dependences.

  13. Resonance Damping and Parameter Design Method for LCL-LC Filter Interfaced Grid-Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Li, Zipeng; Jiang, Aiting; Shen, Pan

    2016-01-01

    , this paper presents a systematic design method for the LCL-LC filtered grid-connected photovoltaic (PV) system. With this method, controller parameters and the active damping feedback coefficient are easily obtained by specifying the system stability and dynamic performance indices, and it is more convenient......-frequency harmonics attenuation ability, but the resonant problem affects the system stability remarkably. In this paper, active damping based on the capacitor voltage feedback is proposed using the concept of the equivalent virtual impedance in parallel with the capacitor. With the consideration of system delay...... to optimize the system performance according to the predefined satisfactory region. Finally, the simulation results are presented to validate the proposed design method and control scheme....

  14. Methodology for Evaluating Safety System Operability using Virtual Parameter Network

    International Nuclear Information System (INIS)

    Park, Sukyoung; Heo, Gyunyoung; Kim, Jung Taek; Kim, Tae Wan

    2014-01-01

    KAERI (Korea Atomic Energy Research Institute) and UTK (University of Tennessee Knoxville) are working on the I-NERI project to suggest complement of this problem. This research propose the methodology which provide the alternative signal in case of unable guaranteed reliability of some instrumentation with KAERI. Proposed methodology is assumed that several instrumentations are working normally under the power supply condition because we do not consider the instrumentation survivability itself. Thus, concept of the Virtual Parameter Network (VPN) is used to identify the associations between plant parameters. This paper is extended version of the paper which was submitted last KNS meeting by changing the methodology and adding the result of the case study. In previous research, we used Artificial Neural Network (ANN) inferential technique for estimation model but every time this model showed different estimate value due to random bias each time. Therefore Auto-Associative Kernel Regression (AAKR) model which have same number of inputs and outputs is used to estimate. Also the importance measures in the previous method depend on estimation model but importance measure of improved method independent on estimation model. Also importance index of previous method depended on estimation model but importance index of improved method is independent on estimation model. In this study, we proposed the methodology to identify the internal state of power plant when severe accident happens also it has been validated through case study. SBLOCA which has large contribution to severe accident is considered as initiating event and relationship amongst parameter has been identified. VPN has ability to identify that which parameter has to be observed and which parameter can be alternative to the missing parameter when some instruments are failed in severe accident. In this study we have identified through results that commonly number 2, 3, 4 parameter has high connectivity while

  15. Methodology for Evaluating Safety System Operability using Virtual Parameter Network

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sukyoung; Heo, Gyunyoung [Kyung Hee Univ., Yongin (Korea, Republic of); Kim, Jung Taek [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Tae Wan [Kepco International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-05-15

    KAERI (Korea Atomic Energy Research Institute) and UTK (University of Tennessee Knoxville) are working on the I-NERI project to suggest complement of this problem. This research propose the methodology which provide the alternative signal in case of unable guaranteed reliability of some instrumentation with KAERI. Proposed methodology is assumed that several instrumentations are working normally under the power supply condition because we do not consider the instrumentation survivability itself. Thus, concept of the Virtual Parameter Network (VPN) is used to identify the associations between plant parameters. This paper is extended version of the paper which was submitted last KNS meeting by changing the methodology and adding the result of the case study. In previous research, we used Artificial Neural Network (ANN) inferential technique for estimation model but every time this model showed different estimate value due to random bias each time. Therefore Auto-Associative Kernel Regression (AAKR) model which have same number of inputs and outputs is used to estimate. Also the importance measures in the previous method depend on estimation model but importance measure of improved method independent on estimation model. Also importance index of previous method depended on estimation model but importance index of improved method is independent on estimation model. In this study, we proposed the methodology to identify the internal state of power plant when severe accident happens also it has been validated through case study. SBLOCA which has large contribution to severe accident is considered as initiating event and relationship amongst parameter has been identified. VPN has ability to identify that which parameter has to be observed and which parameter can be alternative to the missing parameter when some instruments are failed in severe accident. In this study we have identified through results that commonly number 2, 3, 4 parameter has high connectivity while

  16. Sonographic Evaluation of Renal Parameters in Individuals with ...

    African Journals Online (AJOL)

    2018-05-22

    May 22, 2018 ... sonographic parameters can be used to indirectly assess renal function or status. Ultrasound is an ... Hypertension seems to have more effect in the renal cortex than the medulla. ..... due to cost and use of ionizing radiation.

  17. Evaluation of Injection Molding Process Parameters for Manufacturing Polyethylene Terephthalate

    Directory of Open Access Journals (Sweden)

    Marwah O.M.F.

    2017-01-01

    Full Text Available Quality control is an important aspect in manufacturing process. The quality of product in injection moulding is influenced by injection moulding process parameter. In this study, the effect of injection moulding parameter on defects quantity of PET preform was investigated. Optimizing the parameter of injection moulding process is critical to enhance productivity where parameters must operate at an optimum level for an acceptable performance. Design of Experiment (DOE by factorial design approach was used to find an optimum parameter setting and reduce the defects. In this case study, Minitab 17 software was used to analyses the data. The selected input parameters were mould hot runner temperature, water cooling chiller temperature 1 and water cooling chiller temperature 2. Meanwhile, the output for the process was defects quantity of the preform. The relationship between input and output of the process was analyzed using regression method and Analysis of Variance (ANOVA. In order to interpolate the experiment data, mathematical modeling was used which consists of different types of regression equation. Next, from the model, 95% confidence level (p-value was considered and the significant parameter was figured out. This study involved a collaboration with a preform injection moulding company which was Nilai Legasi Plastik Sdn Bhd. The collaboration enabled the researchers to collect the data and also help the company to improve the quality of its production. The results of the study showed that the optimum parameter setting that could reduce the defect quantity of preform was MHR= 88°C, CT1= 24°C and CT2= 27°C. The comparison defect quantity analysis between current companies setting with the optimum setting showed improvement by 21% reduction of defect quantity at the optimum setting. Finally, from the optimization plot, the validation error between the prediction value and experiment was 1.72%. The result proved that quality of products

  18. Two statistics for evaluating parameter identifiability and error reduction

    Science.gov (United States)

    Doherty, John; Hunt, Randall J.

    2009-01-01

    Two statistics are presented that can be used to rank input parameters utilized by a model in terms of their relative identifiability based on a given or possible future calibration dataset. Identifiability is defined here as the capability of model calibration to constrain parameters used by a model. Both statistics require that the sensitivity of each model parameter be calculated for each model output for which there are actual or presumed field measurements. Singular value decomposition (SVD) of the weighted sensitivity matrix is then undertaken to quantify the relation between the parameters and observations that, in turn, allows selection of calibration solution and null spaces spanned by unit orthogonal vectors. The first statistic presented, "parameter identifiability", is quantitatively defined as the direction cosine between a parameter and its projection onto the calibration solution space. This varies between zero and one, with zero indicating complete non-identifiability and one indicating complete identifiability. The second statistic, "relative error reduction", indicates the extent to which the calibration process reduces error in estimation of a parameter from its pre-calibration level where its value must be assigned purely on the basis of prior expert knowledge. This is more sophisticated than identifiability, in that it takes greater account of the noise associated with the calibration dataset. Like identifiability, it has a maximum value of one (which can only be achieved if there is no measurement noise). Conceptually it can fall to zero; and even below zero if a calibration problem is poorly posed. An example, based on a coupled groundwater/surface-water model, is included that demonstrates the utility of the statistics. ?? 2009 Elsevier B.V.

  19. Relativistic theory of nuclear magnetic resonance parameters in a Gaussian basis representation

    International Nuclear Information System (INIS)

    Kutzelnigg, Werner; Liu Wenjian

    2009-01-01

    The calculation of NMR parameters from relativistic quantum theory in a Gaussian basis expansion requires some care. While in the absence of a magnetic field the expansion in a kinetically balanced basis converges for the wave function in the mean and for the energy with any desired accuracy, this is not necessarily the case for magnetic properties. The results for the magnetizability or the nuclear magnetic shielding are not even correct in the nonrelativistic limit (nrl) if one expands the original Dirac equation in a kinetically balanced Gaussian basis. This defect disappears if one starts from the unitary transformed Dirac equation as suggested by Kutzelnigg [Phys. Rev. A 67, 032109 (2003)]. However, a new difficulty can arise instead if one applies the transformation in the presence of the magnetic field of a point nucleus. If one decomposes certain contributions, the individual terms may diverge, although their sum is regular. A controlled cancellation may become difficult and numerical instabilities can arise. Various ways exist to avoid these singularities and at the same time get the correct nrl. There are essentially three approaches intermediate between the transformed and the untransformed formulation, namely, the bispinor decomposition, the decomposition of the lower component, and the hybrid unitary transformation partially at operator and partially at matrix level. All three possibilities were first considered by Xiao et al. [J. Chem. Phys. 126, 214101 (2007)] in a different context and in a different nomenclature. Their analysis and classification in a more general context are given here for the first time. Use of an extended balanced basis has no advantages and has other drawbacks and is not competitive, while the use of a restricted magnetic balance basis can be justified.

  20. Evaluation of human thyroid tumors by proton nuclear magnetic resonance

    International Nuclear Information System (INIS)

    deCertaines, J.; Herry, J.Y.; Lancien, G.; Benoist, L.; Bernard, A.M.; LeClech, G.

    1982-01-01

    Proton nuclear magnetic resonance (NMR) was used in a study of 40 patients with thyroid tumors following partial or total thyroidectomy. Three patient groups were considered: those with nodules showing increased uptake, those with solitary nodules with decreased uptake, and those with multinodular goiters. Spin-lattice and spin-spin relaxation times (T 1 and T 2 ) were measured on samples of nodular and extranodular tissue from each patient. Increased T 1 and T 2 were observed for benign cold nodules, an increase in T 1 alone for nodules with increased uptake, and a wide fluctuation in T 1 and T 2 for multinodular goiters. The four cancers in the series did not show a distinctive proton NMR pattern in comparison with the other nodular structures studied. The results point to the feasibility of applying NMR techniques to the detection of thyroid disease

  1. Evaluation of aortic regurgitation using cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tamai, Takuya; Konishi, Tokuji; Okamoto, Shinya; Sakuma, Hajime; Takeda, Kan; Nakano, Takeshi

    1993-01-01

    Cine magnetic resonance imaging (MRI) was used to assess aortic regurgitation (AR) in 13 patients with valvular disease and 3 normal subjects, and the results were compared to color Doppler flow mapping findings. AR produced a signal void in the left ventricle during the diastolic phase in all patients by MRI. There were no false positive or negative results compared with echocardiographic findings. Visual grading of cine MRI gave results similar to color flow Doppler echocardiography (88%). The distance and the area of aortic regurgitation using MRI correlated well with color Doppler flow mapping (r=0.82 and 0.88). However, measurements of distance and area by color flow Doppler tended to be larger than those by cine MRI. With current techniques echocardiography may overestimate the severity of AR as compared with cine MRI. In addition, MRI gives clinically useful information in patients in whom transthoracic Doppler echocardiography is not adequate. (author)

  2. Conservative treatment of bronchobiliary fistula evaluated with magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Adžić-Vukičević Tatjana N.

    2015-01-01

    Full Text Available Introduction. Bronchobiliary fistula (BBF is a pathological communication between the bronchial system and the biliary tree that presents with bilioptysis. Many conditions can cause its development. There is still no optimal therapy for BBF. Conservative treatment is rarely indicated, as was published before in a few cases. Case report. We presented a 71-year-old Caucasian Serbian woman with BBF secondary to previous laparotomy due to multiple echinococcus liver cysts. The diagnosis was established by the presence of bilirubin and bile acids in sputum and magnetic resonance cholangiopancreatography (MRCP. A repeat MRCP performed after conservative procedure, did not reveal fistulous communication. Conclusion. We suggest that in small and less severe fistulas between the biliary and the bronchial tract, conservative treatment may be used successfully, and invasive treatment methods are not needed in all patients.

  3. Evaluation of right ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Stubgaard, M; Thomsen, C

    1988-01-01

    stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume......Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular...... determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles...

  4. Magnetic resonance imaging in evaluating workers' compensation patients.

    Science.gov (United States)

    Babbel, Daniel; Rayan, Ghazi

    2012-04-01

    We studied the utility of magnetic resonance imaging (MRI) studies for workers' compensation patients with hand conditions in which the referring doctor obtained the images. We compared the MRI findings with the eventual clinical findings. We also investigated the approximate cost of these MRI studies. We retrospectively reviewed the charts of all workers' compensation patients seen in a hand and upper extremity practice over the course of 3 years. We selected patients who had MRI studies of the affected upper extremities before referral to the senior author (G.R.). We reviewed the charts for information regarding demographics, referral diagnoses, MRI diagnoses made by the radiologist, the area of the upper extremity studied, and eventual clinical diagnoses by the senior author. We made a determination as to whether a hand surgeon could have adequately diagnosed and treated the patients' conditions without the imaging studies. We also investigated the cost associated with these MRIs. We included 62 patients with a total of 67 MRI scans in this study. The MRI studies did not contribute to clinically diagnosing the patients' conditions in any of the cases we reviewed. The hand surgeon's clinical diagnosis disagreed with the radiologist's MRI diagnosis in 63% of patients. The MRI was unnecessary to arrive at the clinical diagnosis and did not influence the treatment offered for any of the 62 patients. The total cost for the 67 non-contrast MRI studies was approximately $53,000. Costly imaging studies are frequently done to determine the validity of a patient's reported problems; unfortunately, these tests are frequently unnecessary and waste resources. Magnetic resonance imaging scans may not be the standard for accurate diagnosis and can misdirect care. Therapeutic III. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Complications after liver transplantation: evaluation with magnetic resonance imaging, magnetic resonance cholangiography, and 3-dimensional contrast-enhanced magnetic resonance angiography in a single session

    International Nuclear Information System (INIS)

    Boraschi, P.; Donati, F.; Gigoni, R.; Salemi, S.; Urbani, L.; Filipponi, F.; Falaschi, F.; Bartolozzi, C.

    2008-01-01

    To evaluate a comprehensive magnetic resonance imaging (MRI) protocol as noninvasive diagnostic modality for simultaneous detection of parenchymal, biliary, and vascular complications after liver transplantation. Fifty-two liver transplant recipients suspected to have parenchymal, biliary, and (or) vascular complications underwent our MRI protocol at 1.5T unit using a phased array coil. After preliminary acquisition of axial T 1 w and T 2 w sequences, magnetic resonance cholangiography (MRC) was performed through a breath-hold, thin- and thick-slab, single-shot T 2 w sequence in the coronal plane. Contrast-enhanced magnetic resonance angiography (CEMRA) was obtained using a 3-dimensional coronal spoiled gradient-echo sequence, which enabled acquisition of 32 partitions 2.0 mm thick. A fixed dose of 20 ml gadobenate dimeglumine was administered at 2 mL/s. A post-contrast T 1 w sequence was also performed. Two observers in conference reviewed source images and 3-dimensional reconstructions to determine the presence of parenchymal, biliary, and vascular complications. MRI findings were correlated with surgery, endoscopic retrograde cholangiography (ERC), biopsy, digital subtraction angiography (DSA), and imaging follow-up. MRI revealed abnormal findings in 32 out of 52 patients (61%), including biliary complications (anastomotic and nonanastomotic strictures, and lithiasis) in 31, vascular disease (hepatic artery stenosis and thrombosis) in 9, and evidence of hepatic abscess and hematoma in 2. ERC confirmed findings of MRC in 30 cases, but suggested disease underestimation in 2. DSA confirmed 7 magnetic resonance angiogram (MRA) findings, but suggested disease overestimation in 2. MRI combined with MRC and CEMRA can provide a comprehensive assessment of parenchymal, biliary, and vascular complications in most recipients of liver transplantation. (author)

  6. Evaluation of resonant tunneling transmission coefficient from multilayer structures GaAlAs/GaAs

    Directory of Open Access Journals (Sweden)

    L. Moghaddasi

    2003-12-01

    Full Text Available   A theoretical study of resonant tunneling in multilayered GaAlAs/GaAs structures are presented. The spectrum of resonant energies and its dependence on the barrier structure are analyzed from calculated profiles of barrier transparency versus energy, and from current voltage characteristics computed at selected temperatures and Fermi levels. The present formalism is based on the effective mass approximation and results are via direct numerical evaluations.

  7. Production of a hot ion plasma at the lower hybrid resonance and measurement of its parameters

    International Nuclear Information System (INIS)

    Glagolev, V.M.; Dyubajlov, A.G.; Krivov, N.A.; Martynenko, V.V.; Skosyrev, Yu.V.

    1975-01-01

    Electromagnetic fields delayed along a magnetic field have been created within a plasma with the aid of a coil encircling the plasma column. When these waves were propagated transversely in relation to the magnetic field in a plasma with density rising along its radius, they were delayed in the direction of propagation. The amplitude and phase distributions of the electromagentic fields along the radius of the plasma column were measured at different moments in time. The existence of an absorption band of these waves within the plasma was detected. The absorption band was shifted towards the outer boundary from the plasma when plasma density was increased. By four independent methods it was established that the gas-kinetic pressure of the plasma, measured according to its diamagnetism, is determined by the ion component. It was found that the energy of electrons at right angles to the magnetic field is considerably less than that of the ions. The cause of limited heating was an increase in density and energy losses in the charge-exchange process. In order to improve vacuum conditions, the coil around the plasma was placed in a metallic chamber, and the UHF plasma source used in the original experiments was replaced by a hydride-film source. This made it possible to increase the internal energy of the plasma to 3x10 15 eV cm -3 at a density of (1-3)x10 12 cm -3 . The mean energy of atoms leaving the plasma at right angles to the magnetic field as a result of charge exchange reached 1 keV. The region of change in plasma parameters (density and magnetic field) for which heating was observed corresponded to the linear transformation theory. Non-linear effects could occur only in the first stage of heating, when the electric fields were strong, but plasma temperature was low. Heating efficiency was measured by a reflectometer installed in the coaxial line connecting the generator and the HF input coil to the plasma. The measurements showed that about 20% of the power

  8. Strain and order-parameter coupling in Ni-Mn-Ga Heusler alloys from resonant ultrasound spectroscopy

    Science.gov (United States)

    Salazar Mejía, C.; Born, N.-O.; Schiemer, J. A.; Felser, C.; Carpenter, M. A.; Nicklas, M.

    2018-03-01

    Resonant ultrasound spectroscopy and magnetic susceptibility experiments have been used to characterize strain coupling phenomena associated with structural and magnetic properties of the shape-memory Heusler alloy series Ni50 +xMn25 -xGa25 (x =0 , 2.5, 5.0, and 7.5). All samples exhibit a martensitic transformation at temperature TM and ferromagnetic ordering at temperature TC, while the pure end member (x =0 ) also has a premartensitic transition at TP M, giving four different scenarios: TC>TP M>TM,TC>TM without premartensitic transition, TC≈TM , and TCparameters relating to magnetic ordering, a soft mode, and the electronic instability responsible for the large strains typical of martensitic transitions. Linear-quadratic or biquadratic coupling between these order parameters, either directly or indirectly via the common strains, is then used to explain the stabilities of the different structures. Acoustic losses are attributed to critical slowing down at the premartensite transition, to the mobility of interphases between coexisting phases at the martensitic transition, and to mobility of some aspect of the twin walls under applied stress down to the lowest temperatures at which measurements were made.

  9. Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry: The Influence of Laser Parameters on Relative Ionization Probability

    Energy Technology Data Exchange (ETDEWEB)

    Isselhardt, Brett H. [Univ. of California, Berkeley, CA (United States)

    2011-09-01

    Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure relative uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process to provide a distinction between uranium atoms and potential isobars without the aid of chemical purification and separation. We explore the laser parameters critical to the ionization process and their effects on the measured isotope ratio. Specifically, the use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of 235U/238U ratios to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser in a 3-color, 3-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from >10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variation in laser parameters on the measured isotope ratio. This work demonstrates that RIMS can be used for the robust measurement of uranium isotope ratios.

  10. The role of magnetic resonance cholangiography in the evaluation of biliary anatomy in living liver donors

    International Nuclear Information System (INIS)

    Arruda, Elaine Cristina de Moraes; Coelho, Julio Cezar Uili; Matias, Jorge Eduardo Fouto

    2008-01-01

    Objective: The present study was aimed at evaluating the accuracy of magnetic resonance cholangiography in the assessment of the biliary anatomy in living liver donors in correlation with surgical findings. Materials And Methods: Fifty living liver donors were retrospectively evaluated at Hospital de Clinicas da Universidade Federal do Parana, Curitiba, PR, Brazil. Cholangiographic images were analyzed and results were compared with intraoperative findings. Only anatomical alterations that affected the surgical strategy and had not been previously observed at magnetic resonance cholangiography were considered as being in disagreement. Results: Anatomical variations were found in 7 donors at magnetic resonance cholangiography, and in 14 during surgery. Agreement between imaging and surgical findings was observed in 41 of the 50 patients, and disagreement in 9. Magnetic resonance cholangiography sensitivity, specificity, positive and negative predictive values, and accuracy were respectively 43%, 97%, 86%, 81% and 81.6%. Conclusion: Magnetic resonance imaging is a safe and non invasive method for preoperative evaluation of the biliary tract in living liver donors. However some anatomical abnormalities are not detected by magnetic resonance cholangiography. (author)

  11. Evaluation of the growth parameters of six commercial crossbred pig ...

    African Journals Online (AJOL)

    To test whether animals grown under ideal temperature conditions would have different growth parameters to animals grown in more conventional housing, 60 Large White x Landrace male pigs from three genotypes were housed in six temperature-controlled chambers. The results were compared with data from a similar ...

  12. Evaluation of Neonatal Hemolytic Jaundice: Clinical and Laboratory Parameters

    Directory of Open Access Journals (Sweden)

    Anet Papazovska Cherepnalkovski

    2015-12-01

    CONCLUSIONS: The laboratory profile in ABO/Rh isoimmunisation cases depicts hemolytic mechanism of jaundice. These cases carry a significant risk for early and severe hyperbilirubinemia and are eligible for neurodevelopmental follow-up. Hematological parameters and blood grouping are simple diagnostic methods that assist the etiological diagnosis of neonatal hyperbilirubinemia.

  13. Evaluation of some handling and processing parameters for ...

    African Journals Online (AJOL)

    Biomass materials require reduction and densification for the purpose of handling and space requirements. Guinea corn (Sorghum bi-color) is a major source of biomass material in the tropic regions. The densification process involves some measurable parameters, namely: pressure, particles size and binder ratio. Guinea ...

  14. Evaluation of selected parameters of rat liver and kidney function ...

    African Journals Online (AJOL)

    The effects of administration of yohimbine, an aphrodisiac on some functional parameters of rat liver and kidney were investigated. White male albino rats weighing between 200-250g were grouped into two such that one group was orally administered with 14mg/kg body weight on daily basis for 15days while the control ...

  15. Dose evaluation due to electron spin resonance method

    International Nuclear Information System (INIS)

    Nakajima, Toshiyuki

    1989-01-01

    Radiation dosimeter has been developed with free radical created in sucrose. Free radical was observed with using the electron spin resonance (ESR) equipment. The ESR absorption due to free radical in sucrose appeared at the magnetic field between the third and fourth ESR ones of Mn +2 standard sample. Sucrose as radiation dosimeter can linearly measure the dose from 5 x 10 -3 Gy to 10 5 Gy. If the new model of the ESR equipment is used and ESR observation is carried out at lower temperature such as liquid nitrogen or liquid helium temperature, the sucrose ESR dosimeter will be detectable about 5 x 10 -4 Gy or less. Fading of the free radicals in the irradiated sucrose was scarcely obtained about six months after irradiation and in the irradiated sucrose stored at 55deg C and 100deg C for one hour or more also scarcely observed. It is concluded from these radiation property that sucrose is useful for the accidental or emergency dosimeter for the inhabitants. (author)

  16. The use of tritiated water in evaluating animal production parameters

    International Nuclear Information System (INIS)

    Robertshaw, D.

    1988-01-01

    Tritiated water (TOH) provides a means of measuring a number of parameters of importance not only to the applied animal physiologist but to those involved in assessing animal productivity. For the examination of animal-environment interactions, TOH is an invaluable tool for assessing total body water, water turnover rate and hence water requirements of different types of animals kept under a variety of climatic and other conditions. It can also be useful for measuring water losses, e.g. through evaporation, and hence is a tool for assessing thermal stress. For animal productivity studies, TOH is useful for assessing such parameters as carcass composition, the intake of forages, supplements and milk. Each of these aspects is described as are the assumptions which have to be made when using TOH for the measurements concerned. (author). 11 refs, 1 tab

  17. Experimental evaluation of a modal parameter based system identification procedure

    Science.gov (United States)

    Yu, Minli; Feng, Ningsheng; Hahn, Eric J.

    2016-02-01

    Correct modelling of the foundation of a rotor bearing foundation system (RBFS) is an invaluable asset for the balancing and efficient running of turbomachinery. Numerical experiments have shown that a modal parameter based identification approach could be feasible for this purpose but there is a lack of experimental verification of the suitability of such a modal approach for even the simplest systems. In this paper the approach is tested on a simple experimental rig comprising a clamped horizontal bar with lumped masses. It is shown that apart from damping, the proposed approach can identify reasonably accurately the relevant modal parameters of the rig; and that the resulting equivalent system can predict reasonably well the frequency response of the rig. Hence, the proposed approach shows promise but further testing is required, since application to identifying the foundation of an RBFS involves the additional problem of accurately obtaining the force excitation from motion measurements.

  18. Multivariate modelling of prostate cancer combining magnetic resonance derived T2, diffusion, dynamic contrast-enhanced and spectroscopic parameters

    Energy Technology Data Exchange (ETDEWEB)

    Riches, S.F.; Payne, G.S.; Morgan, V.A.; DeSouza, N.M. [Royal Marsden NHS Foundation Trust and Institute of Cancer Research, CRUK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Dearnaley, D. [Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Department of Urology and Department of Academic Radiotherapy, Sutton, Surrey (United Kingdom); Morgan, S. [The Ottawa Hospital Cancer Centre and the University of Ottawa, Division of Radiation Oncology, Ottawa, Ontario (Canada); Partridge, M. [The Institute of Cancer Research, Section of Radiotherapy and Imaging, Sutton, Surrey (United Kingdom); University of Oxford, The Gray Institute for Radiation Oncology and Biology, Oxford (United Kingdom); Livni, N. [Royal Marsden NHS Foundation Trust Chelsea, Department of Histopathology, London (United Kingdom); Ogden, C. [Royal Marsden NHS Foundation Trust Chelsea, Department of Urology, London (United Kingdom)

    2015-05-01

    The objectives are determine the optimal combination of MR parameters for discriminating tumour within the prostate using linear discriminant analysis (LDA) and to compare model accuracy with that of an experienced radiologist. Multiparameter MRIs in 24 patients before prostatectomy were acquired. Tumour outlines from whole-mount histology, T{sub 2}-defined peripheral zone (PZ), and central gland (CG) were superimposed onto slice-matched parametric maps. T{sub 2,} Apparent Diffusion Coefficient, initial area under the gadolinium curve, vascular parameters (K{sup trans},K{sub ep},V{sub e}), and (choline+polyamines+creatine)/citrate were compared between tumour and non-tumour tissues. Receiver operating characteristic (ROC) curves determined sensitivity and specificity at spectroscopic voxel resolution and per lesion, and LDA determined the optimal multiparametric model for identifying tumours. Accuracy was compared with an expert observer. Tumours were significantly different from PZ and CG for all parameters (all p < 0.001). Area under the ROC curve for discriminating tumour from non-tumour was significantly greater (p < 0.001) for the multiparametric model than for individual parameters; at 90 % specificity, sensitivity was 41 % (MRSI voxel resolution) and 59 % per lesion. At this specificity, an expert observer achieved 28 % and 49 % sensitivity, respectively. The model was more accurate when parameters from all techniques were included and performed better than an expert observer evaluating these data. (orig.)

  19. Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts

    Energy Technology Data Exchange (ETDEWEB)

    Awaji, M. [Niigata University, Department of Radiology, Faculty of Medicine, Niigata (Japan); Okamoto, K. [Niigata University, Center for Integrated Human Brain Science, Brain Research Institute, Niigata (Japan); Nishiyama, K. [Niigata University, Department of Neurosurgery, Brain Research Institute, Niigata (Japan)

    2007-09-15

    With a high likelihood of clinical improvement and low rates of complications, minimally invasive neuroendoscopic surgery is becoming the treatment of choice for symptomatic or growing arachnoid cysts. In neuroendoscopic surgery, visualization of anatomical landmarks is essential in achieving successful fenestration without complications. Because of the restricted visual field in neuroendoscopic surgery, preoperative anatomical assessment is very helpful. Magnetic resonance cisternography (MRC) with high spatial resolution and contrast, using for example 3-D Fourier transformation constructive interference in steady state (CISS) or fast imaging employing steady-state acquisition (FIESTA) sequences, is able to detect the arachnoid cyst wall and neighboring anatomical structures as the anatomical landmarks. We retrospectively reviewed T2-weighted (T2-W) fast spin-echo images, and the MRC and intraoperative findings. Axial and coronal T2-W images (6 and 3 mm thickness, respectively) and axial and coronal 0.8 mm thick MRC images with CISS or FIESTA were obtained from four patients with arachnoid cysts treated by neuroendoscopic surgery. Intraoperative findings were reviewed on videotape recorded during the procedures. At the brain surface, the arachnoid cyst wall could be detected clearly in any of the four patients on MRC images, and was only partly seen in the fourth patient T2-W images. Adjacent important anatomical structures including vessels and cranial nerves, and an enough space for cystocisternostomy were identified on MRC images, and the findings were consistent with the findings during neuroendoscopic surgery. Preoperative identification of the arachnoid cyst wall and surrounding anatomical structures by MRC may help avoid complications and allow safer neuroendoscopic surgery. (orig.)

  20. Evaluation of physico-chemical and microbial parameters on water ...

    African Journals Online (AJOL)

    Microsoft Windows

    Due to heavy discharge of harmful and deleterious substances in river, the biological, chemical and ... This evaluation will be immensely helpful to estimate the effect of ... The discharge of waste water from municipal sewers containing human.

  1. Evaluation of the main parameters affecting seismic performance of ...

    Indian Academy of Sciences (India)

    The current study considers forty eight (48) 3-D RC building models to .... Acceptance criteria for members and performance level criteria for buildings are ..... Evaluation and Retrofit of Concrete Buildings, Applied Technology Council, Vol 1.

  2. Left-ventricular reduction surgery: pre- and postoperative evaluation by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Hamm, B.; Hotz, H.; Konertz, W.; Borges, A.C.; Baumann, G.

    2001-01-01

    Aim: To evaluate the role of cine magnetic resonance imaging (MRI) in the preoperative assessment and postoperative follow-up of patients undergoing left ventricular (LV) reduction surgery. Patients and Methods: 6 patients with cardiomegaly were examined on a 1.5 T MR imager before and after LV reduction surgery. The heart was imaged along the short and long axes using a breath-hold ECG-triggered cine gradient-echo sequence for assessing ventricular and valvular morphology and function and performing volumetry (end-diastolic and end-systolic volumes, ejection fraction). Results: Postoperatively, the mean ejection fraction increased from 21.7% to 33.4% and the enddiastolic and end-systolic left ventricular volumes decreased in all patients (304.0 and 252.5 ml before to 205.0 and 141.9 ml after surgery). Mean myocardial mass decreased slightly from 283.8 g to 242.7 g. Differences were significant for all parameters (p [de

  3. Clinical significance of dynamic magnetic resonance imaging in the evaluation of wrist joint in Rheumatoid arthritis

    International Nuclear Information System (INIS)

    Shim, Yong Woon; Suh, Jin Suck; Lee, Soo Kon; Lee, Ji Soo; Cho, Jae Hyun

    1996-01-01

    To assess the role of contrast-enhanced dynamic Magnetic Resonance Imaging in evaluation disease activity of rheumatoid arthritis. Forty-seven wrist joints with rheumatoid arthritis were examined prospectively. Coronal images of the wrist were obtained using fat-suppression Fast multi-planar spoiled gradient recalled (FMPSPGR) acquisition in the steady state ; TR/TE 102/6.4 msec, flip angle = 60, 4 slices per sequence, FOV = 8 cm, matrix 256 X 192 at 1.5 Tesla. Scans were carried out once before and five to eight times after an intravenous Gd-DPTA injection, at 30-second-intervals. The enhancement of synovium were measured, the enhancement ratio was calculated(postcontrast SNR/precontrast SNR) and time-enhancement ratio curves were plotted. Patients were divided into three groups according to the ratio of initial to peak enhancement : less than 30% ; 30-80% more than 80%. Differences among the three groups were statistically tested using clinical indices and laboratory data as variable. Comparing one group with another, there were no significant differences in clinical indices and laboratory data except for the parameter of grip strength. Enhancement pattern measured in a single wrist joint was not comparable to a clinical index in predicting disease activity in rheumatoid arthritis

  4. Qualitative Parameters for Evaluation Procedures of Non-Formal and Informal Learning Achievements

    Science.gov (United States)

    Stasiunaitiene, Egle; Kaminskiene, Lina

    2009-01-01

    The article introduces evaluation principles of non-formal and informal learning that determine the quality of evaluation, describes stages of the evaluation procedure, differentiates their qualitative parameters and defines their criteria and indicators. It also brings in the discussion that consideration of qualitative parameters for the…

  5. Magnetic Resonance Spectroscopy in evaluation of central nervous system

    International Nuclear Information System (INIS)

    Krolicki, L.; Bak, M.; Grieb, P.

    1996-01-01

    The article presents the current results of MR spectroscopy in evaluation of central nervous system. This method is useful in examination of brain ischemia, brain tumors, epilepsy; white matter disorders and degeneration diseases. MR spectroscopy is unique technique for in vivo examination of the brain in physiological and pathophysiological states. (author)

  6. Magnetic resonance imaging evaluation of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Hachisuka, Hiroki; Kimori, Kenji; Tsuge, Kenya; Murakami, Tsuneji

    2006-01-01

    In many reports, the severity of carpal tunnel syndrome (CTS) is evaluated by subjective symptoms and nerve conduction findings of the median nerve. However, nerve conduction studies are complicated and the patients occasionally experience pain. In this report, we quantified a morphological change in the median nerve by using MRI, and reviewed a new noninvasive method of CTS evaluation. The survey was carried out on 55 idiopathic CTS patients (45 females and 10 males). The affected areas were 33 right hands and 22 left hands. The average age of the patients was 59 years. We used Philips Gyroscan Intera 1.5 Tesla MRI. T2 weighted axial image of the carpal canal sliced by width of 1 mm was used to measure a minimum axis/maximum axis (median nerve compression rate; MNCR). Simultaneously, we measured the nerve conduction velocity and terminal latency of the motor and sensory nerves; we evaluated the thumb motor disturbance by Hamada's classification and sensory disturbance by Semmes-Weinstein test. The statistical correlations between these items and MNCR were analyzed. MNCR had a significant correlation with all items, particularly with motor nerve conduction velocity and latency, and Hamada's classification. There have been some trials regarding the application of MRI findings for CTS evaluation. In these reports, they measured the cross section of the median nerve or brightness of the median nerve, flexor tendon, or intrinsic muscle. However, it is difficult to measure an MRI cross section or brightness in common practice. MNCR has a statistical correlation with the nerve conduction study, is easy to measure, and noninvasive. MNCR is useful as an objective evaluation method of CTS severity. (author)

  7. Determination of the neutron resonance parameters for 206Pb and of the thermal neutron capture cross section for 206Pb and 209Bi

    International Nuclear Information System (INIS)

    Borella, A.

    2005-01-01

    Chapter 1 describes the motivation of the measurements (accelerator driven systems, stellar nucleosynthesis, neutron induced reactions on 206 Pb), the present status of the neutron capture data for 206 Pb and 209 Bi and the structure of this work. In Chapter 2 the basic reaction theory underlying this work is described. The neutron induced reaction mechanism and formalism are explained. The parameterisation of the cross section in terms of R-matrix theory is discussed and we put particular emphasis on the statistical behaviour of the resonance parameters and the impact of the angular distribution of gamma rays following neutron capture. The relation between experimental observables and the resonance parameters is discussed together with general comments related to resonance shape analysis. Chapter 3 is focused on the determination of resonance parameters for 206 Pb. We performed high-resolution transmission and capture measurements at the Time-Of-Flight (TOF) facility GELINA of the IRMM at Geel (B) and determined the resonance parameters. For nuclei like 206 Pb, where the total width is dominated by Γ n , the capture area allows to determine G . Transmission measurements were carried out to determine Γ n , and the statistical factor g of resonances. Before performing a Resonance Shape Analysis (RSA) on the transmission and capture data, we verified the neutron flux and resolution at GELINA. We also compared the characteristics of GELINA with those of the n-TOF facility at CERN. A special emphasis is placed on the total energy detection technique using C 6 D 6 detectors. This technique was applied for the determination of the capture cross section. To reduce systematic bias effects on the capture cross section, the response of the detectors was determined by Monte Carlo simulations, which has been validated by experiments. Using these response functions the partial capture cross sections for individual resonances of 206 Pb have been deduced, by unfolding the

  8. Acute Cardiac Impairment Associated With Concurrent Chemoradiotherapy for Esophageal Cancer: Magnetic Resonance Evaluation

    International Nuclear Information System (INIS)

    Hatakenaka, Masamitsu; Yonezawa, Masato; Nonoshita, Takeshi; Nakamura, Katsumasa; Yabuuchi, Hidetake; Shioyama, Yoshiyuki; Nagao, Michinobu; Matsuo, Yoshio; Kamitani, Takeshi; Higo, Taiki; Nishikawa, Kei; Setoguchi, Taro; Honda, Hiroshi

    2012-01-01

    Purpose: To evaluate acute cardiac effects of concurrent chemoradiotherapy (CCRT) for esophageal cancer. Methods and Materials: This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. The left ventricular function (LVF) of 31 patients with esophageal cancer who received cisplatin and 5-fluorouracil–based CCRT was evaluated using cardiac cine magnetic resonance imaging. The patients were classified into two groups according to mean LV dose. The parameters related to LVF were compared between before and during (40 Gy) or between before and after CCRT using a Wilcoxon matched-pairs single rank test, and parameter ratios (during/before CCRT, after/before CCRT) were also compared between the groups with a t test. Data were expressed as mean ± SE. Results: In the low LV-dose group (n = 10; mean LV dose 2 ), LV stroke volume index (38.6 ± 1.56 vs. 29.9 ± 1.60 mL/m 2 ), and LV ejection fraction (56.9% ± 1.79% vs. 52.8% ± 1.15%) decreased significantly (p < 0.05) after CCRT. Heart rate increased significantly (before vs. during vs. after CCRT; 66.8 ± 3.05 vs. 72.4 ± 4.04 vs. 85.4 ± 3.75 beats per minute, p < 0.01). Left ventricle wall motion decreased significantly (p < 0.05) in segments 8 (before vs. during vs. after CCRT; 6.64 ± 0.54 vs. 4.78 ± 0.43 vs. 4.79 ± 0.50 mm), 9 (6.88 ± 0.45 vs. 5.04 ± 0.38 vs. 5.27 ± 0.47 mm), and 10 (9.22 ± 0.48 vs. 8.08 ± 0.34 vs. 8.19 ± 0.56 mm). The parameter ratios of LV end-diastolic volume index, stroke volume index, wall motion in segment 9, and heart rate showed significant difference (p < 0.05) after CCRT between the groups. Conclusions: Concurrent chemoradiotherapy for esophageal cancer impairs LVF from an early treatment stage. This impairment is prominent in patients with high LV dose.

  9. Assessment on Evaluating Parameters of Rice Core Collections Constructed by Genotypic Values and Molecular Marker Information

    Directory of Open Access Journals (Sweden)

    Jian-cheng WANG

    2007-06-01

    Full Text Available Eleven evaluating parameters for rice core collection were assessed based on genotypic values and molecular marker information. Monte Carlo simulation combined with mixed linear model was used to eliminate the interference from environment in order to draw more reliable results. The coincidence rate of range (CR was the optimal parameter. Mean Simpson index (MD, mean Shannon-Weaver index of genetic diversity (MI and mean polymorphism information content (MPIC were important evaluating parameters. The variable rate of coefficient of variation (VR could act as an important reference parameter for evaluating the variation degree of core collection. Percentage of polymorphic loci (p could be used as a determination parameter for the size of core collection. Mean difference percentage (MD was a determination parameter for the reliability judgment of core collection. The effective evaluating parameters for core collection selected in the research could be used as criteria for sampling percentage in different plant germplasm populations.

  10. EVALUATION OF FERMENTATION PARAMETERS DURING HIGH-GRAVITY BEER PRODUCTION

    Directory of Open Access Journals (Sweden)

    R.B. Almeida

    2001-12-01

    Full Text Available A large number of advantages are obtained from the use of highly concentrated worts during the production of beer in a process referred to as "high-gravity". However, problems related to slow or stuck fermentations, which cause the lower productivity and possibility of contamination, are encountered. This study examines the influence of factors pH, percentage of corn syrup, initial wort concentration and fermentation temperature on the fermentation parameters, namely productivity, wort attenuation and the yield coefficient for sugar-to-ethanol conversion. The results show that productivity increased when the higher temperature, the higher wort concentration and the lower syrup percentage were used, while wort attenuation increased when lower wort concentration and no syrup were used. The yield coefficient for sugar-to-ethanol conversion was not influenced by any of the factors studied.

  11. Evaluating System Parameters on a Dragonfly using Simulation and Visualization

    Energy Technology Data Exchange (ETDEWEB)

    Bhatele, Abhinav [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jain, Nikhil [Univ. of Illinois, Urbana-Champaign, IL (United States); Livnat, Yarden [Univ. of Utah, Salt Lake City, UT (United States); Pascucci, Valerio [Univ. of Utah, Salt Lake City, UT (United States); Bremer, Peer-Timo [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of Utah, Salt Lake City, UT (United States)

    2015-04-24

    The dragon y topology is becoming a popular choice for build- ing high-radix, low-diameter networks with high-bandwidth links. Even with a powerful network, preliminary experi- ments on Edison at NERSC have shown that for communica- tion heavy applications, job interference and thus presumably job placement remains an important factor. In this paper, we explore the e ects of job placement, job sizes, parallel workloads and network con gurations on network through- put to better understand inter-job interference. We use a simulation tool called Damsel y to model the network be- havior of Edison and study the impact of various system parameters on network throughput. Parallel workloads based on ve representative communication patters are used and the simulation studies on up to 131,072 cores are aided by a new visualization of the dragon y network.

  12. Evaluation of Physicochemical and Microbiological Parameters of Smoked Sausages

    Directory of Open Access Journals (Sweden)

    Melinda Nagy

    2015-11-01

    Full Text Available Meat and meat products continue to supply nutrients and play a vital role in human life because of their high biological value protein, iron, zinc, selenium and vitamin B12 contents, being a crucial component of a well balanced diet. The objective of this paper was to analyse the microbiological and physicochemical characteristics of smoked sausage obtain by a modern recipe. The meat  material was obtained from local butchery (Cluj-Napoca, Romania. The physicochemical analyses highlighted the moisture (Drying-oven at 105 ºC, protein (Kjeldahl method and fat (Soxhlet method content, as well as nitrite (Griess method and sodium chloride concentrations (Mohr method of the final products. Microbiological and physicochemical analysis of the examined samples found no deviations from legal norms imposed for smoked sausage.  All of the quality parameters comply with the limits stipulated by STAS. 

  13. Theoretical evaluation of self-shielding factors due to scattering resonances in foils

    International Nuclear Information System (INIS)

    Selander, W.N.

    1960-06-01

    A semi-analytical method is given for evaluating self-shielding factors for activation measurements which use thin foils having neutron scattering resonances. The energy loss by scattering in the foil is taken into account. The energy-dependent neutron angular distribution is expanded as a double series, the coefficients of which are (energy dependent) solutions of an infinite set of coupled integral equations. These are truncated in some suitable manner and solved numerically. The leading term of the series is proportional to the average, or effective flux in the activation sample. The product of this terra and the neutron capture cross-section is integrated numerically over the resonance to give the resonance self-shielding correction. Figure 4 shows resonance self-shielding factors derived in this mariner for the 132ev resonance in Co-59 and figure 5 shows similar results for the two Mn-55 resonances at 337ev and 1080ev. Self-shielding factors for 1/v capture are not significantly different from unity. (author)

  14. RIDE vs. CLASP Comparison and Evaluation: Models and Parameters

    Science.gov (United States)

    2007-04-01

    the model is declared "No Decision," indicating that neither QLRM nor LLRM provides a satisfactory fit. If p-value ( i 2j ) > p-value ( flj ), then our...evaluated at A = D = loo tD (7) UA/D(70,40) = 37.35 (8) UA/D(70,100) = 22.93 (9) OUA/D = 0 when evaluated at A = 70, D = 65.7 aD Note the number of...M U) U) C)U)f-~H W 0 U) co CQ CU)QC) W W 0 O40U) El)U tq D O U) U) E U) Z 04 X L X 4j c)c: o n n , f)cj" D ,m u)o mm o:zz .o tD o U) Uti)U) ’-4 r-4

  15. Evaluation of Stress Parameters Based on Heart Rate Variability Measurements

    OpenAIRE

    Uysal, Fatma; Tokmakçı, Mahmut

    2018-01-01

    In this study, heart rate variabilitymeasurements and analysis was carried with help of the ECG recordings to showhow autonom nervous system activity changes. So as to evaluate the parametersrelated to stress of the study, the situation of relaxation, Stroop color/wordtest, mental test and auditory stimulus that would stress someone out wereapplied to six volunteer participants in a laboratory environment. Being takentotally seven minutes ECG recording and made analysis in time and frequencyd...

  16. Evaluation of pleural and pericardial effusions by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tscholakoff, D.; Sechtem, U.; De Geer, G.; Schmidt, H.; Higgins, C.B.

    1987-08-01

    MR examinations of 36 patients with pleural and/or pericardial effusions were retrospectively evaluated. The purpose of this study was to determine of MR imaging is capable of differentiating between pleural and pericardial effusions of different compositions using standard electrocardiogram (ECG)-gated and nongated spin echo pulse sequences. Additional data was obtained from experimental pleural effusions in 10 dogs. The results of this study indicate that old haemorhages into the pleural or pericardial space can be differentiated from other pleural or pericardial effusions. However, further differentiation between transudates, exudates and sanguinous effusions is not possible on MR images acquired with standard spin echo pulse sequences. (orig./MG)

  17. Evaluation of RF seals for resonant cavity applications

    International Nuclear Information System (INIS)

    Rusnak, B.; Spalek, G.; Bolme, G.O.; Bultman, N.; Klapetkzy, A.; Kemp, E.L.; Stovall, J.E.; Rose, J.

    1991-01-01

    In radio-frequency quadrupoles (RFQ) and drift-tube linacs (DTL), electrical seals are required at mechanical interfaces to preserve the cavity quality factor (Q). Studies determined the response of copper-plated C-seals to continuous wave (cw), highfield operating conditions. In addition, low-power evaluations of machined-surface, knife-edge, indium wire, C-type, and multilam seals were done at room temperature and cryogenic (25 K) temperatures. For the high-field tests, the Q as well as seal temperature, was measured with power. For the low power test, the Q was measured as a function of temperature

  18. Magnetic resonance imaging in assessment of stress urinary incontinence in women: Parameters differentiating urethral hypermobility and intrinsic sphincter deficiency.

    Science.gov (United States)

    Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene

    2015-11-28

    To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P continent volunteers and incontinent patients in body habitus as assessed by the body mass

  19. Magnetic resonance imaging for evaluation of congenital heart disease

    International Nuclear Information System (INIS)

    Niwa, Koichiro; Uchishiba, Mika; Tateno, Shigeru; Aotsuka, Hiroyuki; Nakatani, Hayao; Matsuo, Kozo; Fujiwara, Tadashi; Tashima, Kazuyuki.

    1992-01-01

    We applied the segmental analysis of cardiac MR images for evaluation of congenital heart diseases (CHD). One hundred and ninety-three patients with CHD, ranging in age from 20 days to 18 years old, were studied by MRI. This study compared the effectiveness of MRI with cardiac angiography and echocardiography for the evaluation of major diagnosis of CHD and all components of cardiovascular anatomy. ECG-gated MRI was performed by spin echo and gradient refocused imaging techniques operating at 0.5 tesla. In all the patients not only cardiovascular anatomies of CHD but all structures relevant to the identification of arrangement of organs were displayed. In diagnosing a total of 193 of major cardiac anomalies and 741 segments of the vein, the atrium, the ventricle and the great vessels by MRI and angiocardiogram and/or echocardiogram, descrepancies were found in 6 patients (3.1%), and only 18 segments (2.4%), respectively. For vascular and complex cardiac anatomies MRI was able to provide good anatomical details. Based on these findings, the segmental analysis of cardiac MR images was found useful for achieving a systematic diagnosis of CHD. (author)

  20. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  1. Evaluation of ground stiffness parameters using continuous surface wave geophysics

    DEFF Research Database (Denmark)

    Gordon, Anne; Foged, Niels

    2000-01-01

    Present day knowledge of the magnitude of the strain levels in the ground associated with geotechnical structures, together with an increasing number of projects requiring the best estimates of ground movements around excavations, has led to, inter alia, increased interest in measuring the very......-small-strain stiffness of the ground Gmax. Continuous surface wave geophysics offers a quick, non-intrusive and economical way of making such measurements. This paper reviews the continuous surface wave techniques and evaluates, in engineering terms, the applicability of the method to the site investigation industry....

  2. New experimental determination of the neutron resonance parameters of {sup 99}Tc; Nouvelle determination experimentale des parametres de resonances neutroniques de {sup 99}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Brienne-Raepsaet, C. [CEA Bruyeres-le-Chatel, 91 (France). Dept. de Physique Theorique et Appliquee]|[Aix-Marseille-1 Univ., 13 - Marseille (France)

    1999-04-01

    In order to improve nuclear data for nuclear waste transmutation cross-sections of Tc{sup 99} in the resonance energy region have been performed using the time-of-flight method at the pulsed white neutron source GELINA of the Institute for Reference Materials and Measurements, Geel, Belgium. The energy range studied spreads from 3 eV to 100 KeV. 2 kinds of measurements have been performed: capture and transmission measurements. In the energy range between 0 and 2 KeV, more than 220 resonances have been analyzed. About 130 resonances which had stayed previously undiscovered, have been detected and analyzed. Because of instability problems concerning the process of measuring itself, the systematic error is not yet determined. The accuracy which takes into account statistical and systematic errors is expected to be between 4 and 5%.

  3. Application of electron spin resonance for evaluation of the level of ...

    Indian Academy of Sciences (India)

    Abstract. In order to identify and quantify free radicals in the tissues of patients with normal physiological and pathological states of births, we developed a method to evaluate the amount of free radicals in myometrium of subplacental area and from body of uterus, using electron spin resonance spectroscopy. Analysis of the ...

  4. Methodologies for semiquantitative evaluation of hip osteoarthritis by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jaremko, Jacob L; Lambert, Robert G W; Zubler, Veronika

    2014-01-01

    As a wider variety of therapeutic options for osteoarthritis (OA) becomes available, there is an increasing need to objectively evaluate disease severity on magnetic resonance imaging (MRI). This is more technically challenging at the hip than at the knee, and as a result, few systematic scoring...

  5. Ultrasound and magnetic resonance imaging in the evaluation of psoriatic dactylitis

    DEFF Research Database (Denmark)

    Bakewell, Catherine J; Olivieri, Ignazio; Aydin, Sibel Z

    2013-01-01

    ) and magnetic resonance imaging (MRI) literature to better define imaging elements that contribute to the dactylitic digit seen in PsA. Our objectives were to determine first the level of homogeneity of each imaging modality's definition of the components of dactylitis, and second, to evaluate the metric...

  6. Comparative evaluation of qigong on various parameters of saliva

    Directory of Open Access Journals (Sweden)

    Bayat Movahed S.

    2007-05-01

    Full Text Available Background and Aim: Qigong is a type of Chinese psychosomatic exercise that integrates meditation, slow physical movements, and breathing. Numerous physical and mental benefits have been classically ascribed to qigong. On the other hand, unstimulated saliva is thought to play an important role in oral immunity, enamel stability and moisturizing the oral mucous membrane. Impaired salivary secretion leads to dental caries, mucosal deterioration and mouth dryness. The aim of the present study was to analyze the effect of a qigong program on various parameters of saliva such as quantity of unstimulated saliva, pH and SIgA. Materials and Methods: Twenty three subjects participated in this clinical trial study. The experimental subjects underwent a qigong training program, conducted by a qualified instructor. The program consisted of half an hour daily practice for 6 months (spring and winter. Saliva was collected in two periods: once during the spring before the experiment commencement and the second, in the following spring. During each period saliva collection was done on tuesday of each week. pH and quantity of salvia measurements were taken simultaneously. SIgA measurements were also taken based on the values obtained in the last phase of the experiment at the end of each spring. The results were analyzed using paired sample T test, one way repeated measure and Bon Ferroni multiple comparison. P<0.05 was the level of significance. Results: Based on our findings, the change in the amount of unstimulated salvia as well as SIgA was statistically significant (P<0.001; however, there was no significant difference in pH values before and after experiment. Conclusion: These findings demonstrate that after 6 months of practicing qigong, significant changes in amount of unstimulated saliva and SIgA occurred in participants. The authors suggest that qigong may be a beneficial adjunctive treatment that enhances amount of unstimulated saliva and SIgA.

  7. New experimental determination of the neutronic resonance parameters of {sup 237}Np below 500 eV; Nouvelle determination experimentale des parametres de resonances neutroniques de {sup 237}Np en dessous de 500 eV

    Energy Technology Data Exchange (ETDEWEB)

    Gressier, V

    1999-10-01

    For studies of future nuclear reactors dedicated to nuclear waste transmutation, an improvement of the accuracy of the neutron radiative capture cross section of {sup 237}Np appears necessary. In the framework of a collaboration between the Commissariat a l'Energie atomique (CEA) and Institute for Reference Materials and Measurement (IRMM, Geel, Bergium), a new determination of the resonance parameters of {sup 237}Np has been performed. Two types of experiments are carried out at GELINA, the IRMM pulsed neutron source, using the time of flight method: a transmission experiment which is related to the neutron total cross section and a capture experiment which gives the neutron radiative capture cross section. The resonance parameters presented in this work are extracted from the transmission data between 0 and 500 eV with the least square code REFIT, using the Reich-Moore formalism. In parallel, the Doppler effect is investigated. The commonly used free gas model appears inadequate below 20 eV for neptunium dioxide at room temperature. By the use of the program DOPUSH, which calculates the Doppler broadening with a harmonic crystal model according to Lamb's theory, we are able to produce abetter fit of the experimental data for the resonances of {sup 237}Np in NpO{sub 2} at low energy or temperatures. In addition to the resonance parameters, a study of their mean value and distribution is included in this work. (authors)

  8. MAGNETIC RESONANCE IMAGING EVALUATION OF ROTATOR CUFF IMPINGEMENT

    Directory of Open Access Journals (Sweden)

    Chandrakanth K. S

    2017-06-01

    Full Text Available BACKGROUND Shoulder pain is a common clinical problem. Impingement syndrome of the shoulder is believed to be the most common cause of shoulder pain. The term ‘impingement syndrome’ was first used by Neer to describe a condition of shoulder pain associated with chronic bursitis and partial thickness tear of Rotator Cuff (RC. The incidence of Rotator Cuff (RC tear is estimated to be about 20.7% in the general population. This study is intended to analyse various extrinsic and intrinsic causes of shoulder impingement. MATERIALS AND METHODS 110 consecutive patients referred for MRI with clinical suspicion of shoulder impingement were prospectively studied. All the patients were evaluated for Rotator Cuff (RC degeneration and various extrinsic factors that lead to degeneration like acromial shape, down-sloping acromion, Acromioclavicular (AC joint degeneration and acromial enthesophyte. Intrinsic factors like degeneration and its correlation with age of the patients were evaluated. RESULTS Of the total 110 patients, 19 (17.3% patients had FT RC tear and 31 (28.2% had PT (both bursal and articular surface tears. There was no statistically significant correlation (p=0.76 between acromion types and RC tear. Down-sloping acromion and enthesophytes had statistically significant association with RC tear (p=0.008 and 0.008, respectively. Statistically significant (0.008 correlation between the severity of AC joint degeneration and RC tears was noted. AC joint degeneration and RC pathologies also showed a correlation with the age of the patients with p values of <0.001 and 0.001, respectively. CONCLUSION No statistically significant correlation between RC pathologies with hooked acromion was found, that makes the role played by hooked acromion in FT RC tear questionable. AC joint degeneration association with RC tear is due to the association of both RC tear and AC joint degeneration with age of the patient. Down-sloping acromion, AC joint degeneration

  9. Evaluation of new multiaxial damage parameters on low carbon steel

    Directory of Open Access Journals (Sweden)

    A. S. Cruces

    2017-07-01

    Full Text Available Most mechanical components are subjected to the complex fatigue loading conditions, where both amplitude and direction of loading cycles change over the time. The estimation of damage caused by these complex loading scenarios are often done by simplified uniaxial fatigue theories, which ultimately leads to higher factor of safety during the final design considerations. Critical plane-based fatigue theories have been considered more accurate for computing the fatigue damage for multiaxial loading conditions in comparison to energy-based and equivalent stress-based theories. Two recently developed fatigue theories have been evaluated in this work for the available test data. Test data includes significant amount of biaxial load paths.

  10. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    Energy Technology Data Exchange (ETDEWEB)

    Dicle, O. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Kuecuekler, C. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Pirnar, T. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Erata, Y. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey); Posaci, C. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey)

    1997-02-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs.

  11. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    International Nuclear Information System (INIS)

    Dicle, O.; Kuecuekler, C.; Pirnar, T.; Erata, Y.; Posaci, C.

    1997-01-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs

  12. American National Standard: guidelines for evaluating site-related geotechnical parameters at nuclear power sites

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard presents guidelines for evaluating site-related geotechnical parameters for nuclear power sites. Aspects considered include geology, ground water, foundation engineering, and earthwork engineering. These guidelines identify the basic geotechnical parameters to be considered in site evaluation, and in the design, construction, and performance of foundations and earthwork aspects for nuclear power plants. Also included are tabulations of typical field and laboratory investigative methods useful in identifying geotechnical parameters. Those areas where interrelationships with other standards may exist are indicated

  13. Combined Clinical Parameters and Multiparametric Magnetic Resonance Imaging for Advanced Risk Modeling of Prostate Cancer-Patient-tailored Risk Stratification Can Reduce Unnecessary Biopsies.

    Science.gov (United States)

    Radtke, Jan Philipp; Wiesenfarth, Manuel; Kesch, Claudia; Freitag, Martin T; Alt, Celine D; Celik, Kamil; Distler, Florian; Roth, Wilfried; Wieczorek, Kathrin; Stock, Christian; Duensing, Stefan; Roethke, Matthias C; Teber, Dogu; Schlemmer, Heinz-Peter; Hohenfellner, Markus; Bonekamp, David; Hadaschik, Boris A

    2017-12-01

    Multiparametric magnetic resonance imaging (mpMRI) is gaining widespread acceptance in prostate cancer (PC) diagnosis and improves significant PC (sPC; Gleason score≥3+4) detection. Decision making based on European Randomised Study of Screening for PC (ERSPC) risk-calculator (RC) parameters may overcome prostate-specific antigen (PSA) limitations. We added pre-biopsy mpMRI to ERSPC-RC parameters and developed risk models (RMs) to predict individual sPC risk for biopsy-naïve men and men after previous biopsy. We retrospectively analyzed clinical parameters of 1159 men who underwent mpMRI prior to MRI/transrectal ultrasound fusion biopsy between 2012 and 2015. Multivariate regression analyses were used to determine significant sPC predictors for RM development. The prediction performance was compared with ERSPC-RCs, RCs refitted on our cohort, Prostate Imaging Reporting and Data System (PI-RADS) v1.0, and ERSPC-RC plus PI-RADSv1.0 using receiver-operating characteristics (ROCs). Discrimination and calibration of the RM, as well as net decision and reduction curve analyses were evaluated based on resampling methods. PSA, prostate volume, digital-rectal examination, and PI-RADS were significant sPC predictors and included in the RMs together with age. The ROC area under the curve of the RM for biopsy-naïve men was comparable with ERSPC-RC3 plus PI-RADSv1.0 (0.83 vs 0.84) but larger compared with ERSPC-RC3 (0.81), refitted RC3 (0.80), and PI-RADS (0.76). For postbiopsy men, the novel RM's discrimination (0.81) was higher, compared with PI-RADS (0.78), ERSPC-RC4 (0.66), refitted RC4 (0.76), and ERSPC-RC4 plus PI-RADSv1.0 (0.78). Both RM benefits exceeded those of ERSPC-RCs and PI-RADS in the decision regarding which patient to receive biopsy and enabled the highest reduction rate of unnecessary biopsies. Limitations include a monocentric design and a lack of PI-RADSv2.0. The novel RMs, incorporating clinical parameters and PI-RADS, performed significantly better

  14. Evaluation of magnetic resonance imaging in thoracic inlet tumors

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Eiro (Kobe Univ. (Japan). School of Medicine)

    1993-06-01

    To evaluate the detectability of tumor invasion to the thoracic inlet, MRI was performed in 57 patients with thoracic inlet tumor, and the diagnostic accuracy of MRI was compared with that of CT concerning the utility for thoracic inlet lesions. And we assessed abnormal findings in comparison with surgical or autopsy findings. In the local extent of the tumor, the accuracy for tumor invasion to the vessels such as subclavian artery and vein was 94.9% for MRI, and 83.5% for CT, and to the brachial plexus was 95.0% for MRI, and 60.0% for CT. MRI was superior to CT, but MRI was equivalent to CT with regard to invasion to the base of the neck, lateral chest wall, ribs, and vertebral bodies. However on MRI, it is easier to understand the longitudinal tumor extent than on CT. CT has superior spatial resolusion but CT has also disadvantages, such as streak artifact caused by shoulder joints, resulting in image degradation. In contrast, MRI has inherent advantages, and multiple images which facilitate the relationship between tumor and normal structures. Coronal and sagittal MR images facilitated three-dimensional observation of tumor of invasion in the thoracic inlet. Furthermore to improve image quality of MRI for the thoracic inlet, we newly devised a high molecular polyester shell for fixing a surface coil. On the high resolution MR (HR-MR) imaging using our shell, normal lymph nodes, muscles, blood vessels and the branches of the branchial plexus were clearly visualized in detail. Our shell was simple to process and facilitated immobilization of a surface coil. HR-MR technique produces images of high resolution after simple preparation. In conclusion, MRI was very useful for detecting lesions of the thoracic inlet and in deciding surgical indication and the planning for radiotherapy. (author).

  15. Evaluation of TFC tears with magnetic resonance imaging; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Kushida, Manabu; Imamura, Koutaro; Sumi, Mitsuhiro; Uetani, Masataka (Nagasaki Univ. (Japan). School of Medicine); Nagatani, Yoshifumi

    1993-09-01

    This study evaluated the accuracy of magnetic resonance imaging (MRI) in the detection of tears of the trianglar fibrocartilage (TFC). Eighteen patients with chronic pain in the ulnar side of their wrist were examined by MRI and arthrography. Compared with arthrography, MRI was effective in the evaluation of TFC tears with a sensitivity of 92%, a specificity of 67%, and an accuracy of 83%. (author).

  16. Magnetic Resonance Imaging (MRI) Evaluation of Developmental Delay in Pediatric Patients

    OpenAIRE

    Ali, Althaf S.; Syed, Naziya P.; Murthy, G.S.N.; Nori, Madhavi; Abkari, Anand; Pooja, B.K.; Venkateswarlu, J.

    2015-01-01

    Introduction: Developmental delay is defined as significant delay in one or more developmental domains. Magnetic Resonance Imaging (MRI) is the best modality to investigate such patients. Evaluation of a child with developmental delay is important not only because it allows early diagnosis and treatment but also helpful for parental counseling regarding the outcome of their child and to identify any possible risk of recurrence in the siblings. Thus this study was undertaken to evaluate the de...

  17. Europium resonance parameters from neutron capture and transmission measurements in the energy range 0.01–200 eV

    International Nuclear Information System (INIS)

    Leinweber, G.; Barry, D.P.; Burke, J.A.; Rapp, M.J.; Block, R.C.; Danon, Y.; Geuther, J.A.; Saglime III, F.J.

    2014-01-01

    Highlights: • Metal samples were sealed and imaged with X-rays to determine sample uniformity. • Eleven new resonances were identified below 100 eV. • The resonance regions of 151 Eu and 153 Eu have been extended from 100 to 200 eV. • The thermal total cross section for 151 Eu was measured, up (9 ± 3)% from ENDF/B-VII.1. • Radiation widths were assigned for all resonances from experimental data. - Abstract: Europium is a good absorber of neutrons suitable for use as a nuclear reactor control material. It is also a fission product in the low-yield tail at the high end of the fission fragment mass distribution. Measurements have been made of the stable isotopes with natural and enriched samples. The linear electron accelerator center (LINAC) at the Rensselaer Polytechnic Institute (RPI) was used to explore neutron interactions with europium in the energy region from 0.01 to 200 eV. Neutron capture and transmission measurements were performed by the time-of-flight technique. Two transmission measurements were performed at flight paths of 15 and 25 m with 6 Li glass scintillation detectors. The neutron capture measurements were performed at a flight path of 25 m with a 16-segment sodium iodide multiplicity detector. Resonance parameters were extracted from the data using the multilevel R-matrix Bayesian code SAMMY. A table of resonance parameters and their uncertainties is presented. To prevent air oxidation metal samples were sealed in airtight aluminum cans in an inert environment. Metal samples of natural europium, 47.8 atom% 151 Eu, 52.2 atom% 153 Eu, as well as metal samples enriched to 98.77 atom% 153 Eu were measured. The measured neutron capture resonance integral for 153 Eu is (9.9 ± 0.4)% larger than ENDF/B-VII.1. The capture resonance integral for 151 Eu is (7 ± 1)% larger than ENDF/B-VII.1. Another significant finding from these measurements was a significant increase in thermal total cross section for 151 Eu, up (9 ± 3)% from ENDF/B-VII.1

  18. Resonance parameters of the 6.67-, 20.9-, and 36.8-eV levels in 238U

    International Nuclear Information System (INIS)

    Olsen, D.K.; de Saussure, G.; Perez, R.B.; Difilippo, F.C.

    1976-01-01

    The ENDF/B-IV 238 U cross sections (MAT-1262) yield an effective capture resonance integral in strongly self-shielded situations which is too high. This situation suggests that the ENDF/B capture widths for the first few s-wave levels may be too large. Recent ORELA measurements of transmission through 238 U have been analyzed with a multilevel formula to determine the parameters of the 6.67-, 20.9-, and 36.6-eV levels. These three levels provide 86 percent of the infinitely dilute capture resonance integral

  19. Generation of CR mammographic image for evaluation quality parameters

    International Nuclear Information System (INIS)

    Flores, Mabel B.; Mourao, Arnaldo P.; Centro Federal de Educacao Tecnologica de Minas Gerais

    2017-01-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  20. Evaluation of Anthropometric and Metabolic Parameters in Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Yaşar Yildirim

    2015-01-01

    Full Text Available Aims. Sleep disorders have recently become a significant public health problem worldwide and have deleterious health consequences. Obstructive sleep apnea (OSA is the most common type of sleep-related breathing disorders. We aimed to evaluate anthropometric measurements, glucose metabolism, and cortisol levels in patients with obstructive sleep apnea (OSA. Materials and Methods. A total of 50 patients with a body mass index ≥30 and major OSA symptoms were included in this study. Anthropometric measurements of the patients were recorded and blood samples were drawn for laboratory analysis. A 24-hour urine sample was also collected from each subject for measurement of 24-hour cortisol excretion. Patients were divided equally into 2 groups according to polysomnography results: control group with an apnea-hypopnea index (AHI <5 (n=25 and OSA group with an AHI ≥5 (n=25. Results. Neck and waist circumference, fasting plasma glucose, HbA1c, late-night serum cortisol, morning serum cortisol after 1 mg dexamethasone suppression test, and 24-hour urinary cortisol levels were significantly higher in OSA patients compared to control subjects. Newly diagnosed DM was more frequent in patients with OSA than control subjects (32% versus 8%, p=0.034. There was a significant positive correlation between AHI and neck circumference, glucose, and late-night serum cortisol. Conclusions. Our study indicates that increased waist and neck circumferences constitute a risk for OSA regardless of obesity status. In addition, OSA has adverse effects on endocrine function and glucose metabolism.

  1. Generation of CR mammographic image for evaluation quality parameters

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Mabel B.; Mourao, Arnaldo P., E-mail: mbustos@ufmg.br, E-mail: apratabhz@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Politecnica

    2017-11-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  2. Resonance wood [Picea abies (L.) Karst.]--evaluation and prediction of violin makers' quality-grading.

    Science.gov (United States)

    Buksnowitz, Christoph; Teischinger, Alfred; Müller, Ulrich; Pahler, Andreas; Evans, Robert

    2007-04-01

    The definition of quality in the field of resonance wood for musical instrument making has attracted considerable interest over decades but has remained incomplete. The current work compares the traditional knowledge and practical experience of violin makers with a material-science approach to objectively characterize the properties of resonance wood. Norway spruce [Picea abies (L.) Karst.] has earned a very high reputation for the construction of resonance tops of stringed instruments and resonance boards of keyboard instruments, and was therefore chosen as the focus of the investigation. The samples were obtained from numerous renowned resonance wood regions in the European Alps and cover the whole range of available qualities. A set of acoustical, anatomical, mechanical and optical material properties was measured on each sample. These measurements were compared with subjective quality grading by violin makers, who estimated the acoustical, optical and overall suitability for violin making. Multiple linear regression models were applied to evaluate the predictability of the subjective grading using the measured material characteristics as predictors. The results show that luthiers are able to estimate wood quality related to visible features, but predictions of mechanical and acoustical properties proved to be very poor.

  3. A novel diagnostic parameter, foraminal stenotic ratio using three-dimensional magnetic resonance imaging, as a discriminator for surgery in symptomatic lumbar foraminal stenosis.

    Science.gov (United States)

    Yamada, Kentaro; Abe, Yuichiro; Satoh, Shigenobu; Yanagibashi, Yasushi; Hyakumachi, Takahiko; Masuda, Takeshi

    2017-08-01

    No previous studies have reported the radiological features of patients requiring surgery in symptomatic lumbar foraminal stenosis (LFS). This study aims to investigate the diagnostic accuracy of a novel technique, foraminal stenotic ratio (FSR), using three-dimensional magnetic resonance imaging for LFS at L5-S by comparing patients requiring surgery, patients with successful conservative treatment, and asymptomatic patients. This is a retrospective radiological comparative study. We assessed the magnetic resonance imaging (MRI) results of 84 patients (168 L5-S foramina) aged ≥40 years without L4-L5 lumbar spinal stenosis. The foramina were divided into three groups following standardized treatment: stenosis requiring surgery (20 foramina), stenosis with successful conservative treatment (26 foramina), and asymptomatic stenotic foramen (122 foramina). Foraminal stenotic ratio was defined as the ratio of the length of the stenosis to the length of the foramen on the reconstructed oblique coronal image, referring to perineural fat obliterations in whole oblique sagittal images. We also evaluated the foraminal nerve angle and the minimum nerve diameter on reconstructed images, and the Lee classification on conventional T1 images. The differences in each MRI parameter between the groups were investigated. To predict which patients require surgery, receiver operating characteristic (ROC) curves were plotted after calculating the area under the ROC curve. The FSR showed a stepwise increase when comparing asymptomatic, conservative, and surgical groups (mean, 8.6%, 38.5%, 54.9%, respectively). Only FSR was significantly different between the surgical and conservative groups (p=.002), whereas all parameters were significantly different comparing the symptomatic and asymptomatic groups. The ROC curve showed that the area under the curve for FSR was 0.742, and the optimal cutoff value for FSR for predicting a surgical requirement in symptomatic patients was 50

  4. Criteria for first- and second-order vibrational resonances and correct evaluation of the Darling-Dennison resonance coefficients using the canonical Van Vleck perturbation theory

    International Nuclear Information System (INIS)

    Krasnoshchekov, Sergey V.; Isayeva, Elena V.; Stepanov, Nikolay F.

    2014-01-01

    The second-order vibrational Hamiltonian of a semi-rigid polyatomic molecule when resonances are present can be reduced to a quasi-diagonal form using second-order vibrational perturbation theory. Obtaining exact vibrational energy levels requires subsequent numerical diagonalization of the Hamiltonian matrix including the first- and second-order resonance coupling coefficients. While the first-order Fermi resonance constants can be easily calculated, the evaluation of the second-order Darling-Dennison constants requires more complicated algebra for seven individual cases with different numbers of creation-annihilation vibrational quanta. The difficulty in precise evaluation of the Darling-Dennison coefficients is associated with the previously unrecognized interference with simultaneously present Fermi resonances that affect the form of the canonically transformed Hamiltonian. For the first time, we have presented the correct form of the general expression for the evaluation of the Darling-Dennison constants that accounts for the underlying effect of Fermi resonances. The physically meaningful criteria for selecting both Fermi and Darling-Dennison resonances are discussed and illustrated using numerical examples

  5. Strain tuneable whispering gallery mode resonators in the estimation of the elasto-optic parameters of soft materials

    Science.gov (United States)

    Pissadakis, Stavros; Milenko, Karolina; Aluculesei, Alina; Fytas, George

    2016-04-01

    In this manuscript we present the fabrication and characterization of a novel, polymer whispering gallery modes (WGMs) spherical micro-resonator, formed around the waist of an optical fiber taper. Fiber taper with well attached spheroid works as a cord, fixed on two ends enabling strain application to the resonator body. Controllable elastic elongation of the encapsulated fiber taper causes a change in the shape of the spheroid, which modifies the diameter and directional refractive index of the cavity. These changes influence the wavelength position of the WGMs resonances with a linear blue shift up to 0.6 nm, with corresponding strains up to 700Μɛ. The strain induced WGMs shift with respect to resonator diameter and annealing process is presented and analyzed.

  6. Evaluation of dysthyroid optic neuropathy using T2-relaxation time of extraocular muscle as parameter

    International Nuclear Information System (INIS)

    Yu, Fumihiko; Maeda, Toshine; Inoue, Toyoko; Inoue, Yoichi

    2001-01-01

    The T2 value of magnetic resonance imaging (MRI) is useful in evaluating the activity of dysthyroid ophthlamopathy. We applied this method in evaluating dysthyroid optic neuropathy in 15 affected eyes of 15 patients. Another group of 40 eyes of 20 patients of dysthyroid opthalmopathy without hypertrophy of extraocular muscles served as control. The T2 value in dysthyroid optic neuropathy significantly decreased following treatment with corticosteroid but the value was still higher than that in control eyes. The findings show that the T2 value of MRI is useful in evaluating the therapeutic effect of dysthyroid optic neuropathy. (author)

  7. Evaluation of dysthyroid optic neuropathy using T2-relaxation time of extraocular muscle as parameter

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Fumihiko; Maeda, Toshine; Inoue, Toyoko; Inoue, Yoichi [Olympia Eye Hospital, Tokyo (Japan)

    2001-11-01

    The T2 value of magnetic resonance imaging (MRI) is useful in evaluating the activity of dysthyroid ophthlamopathy. We applied this method in evaluating dysthyroid optic neuropathy in 15 affected eyes of 15 patients. Another group of 40 eyes of 20 patients of dysthyroid opthalmopathy without hypertrophy of extraocular muscles served as control. The T2 value in dysthyroid optic neuropathy significantly decreased following treatment with corticosteroid but the value was still higher than that in control eyes. The findings show that the T2 value of MRI is useful in evaluating the therapeutic effect of dysthyroid optic neuropathy. (author)

  8. Bone injuries in the post-traumatic knee: evaluation by magnetic resonance imaging

    International Nuclear Information System (INIS)

    De Grossi, Carla Martins; Marchiori, Edson; Santos, Alair Augusto S.M.D. dos

    2001-01-01

    This paper presents the results of 50 patients with trauma of the knee submitted to magnetic resonance imaging in the period of January 1996 to December 1997. The appearance and incidence of the main bone lesions were evaluated and correlated with the mechanisms of aggression and with clinical data. Associated lesions were also evaluated. Bone contusions were the most commonly findings encountered and were observed in 38 patients (76%). Osteochondral fractures occurred in five patients (10%) and bone fractures were detected in five patients (10%), of which two were associated with contusions in other adjoining bone compartments. Chondromalacia of the patella was observed only in two patients (4%). We concluded that magnetic resonance imaging is the imaging method of choice for the diagnosis of bone lesions in patients with trauma of the knee. (author)

  9. Evaluation of poly(vinylpyrrolidone) and collagen by Low Field Nuclear Magnetic Resonance Spectroscopy

    International Nuclear Information System (INIS)

    Costa, Paula de M.; Tavares, Maria I.B.

    2005-01-01

    Blends of natural and synthetic polymers represent a new class of materials with better mechanical properties and biocompatibility than those of the single components. Collagen and poly(vinylpyrrolidone) are well known for their important biological properties. The blending of collagen with poly(vinylpyrrolidone) makes it possible to obtain new materials in which strong interactions between the synthetic and biological components occur. Do to the excellent biocompatibility of these polymers, this blend has been much studied intending biomedical applications. And a one technique that can provide important information on molecular mobility, compatibility and even evaluate the interactions that can occur with these polymers is the Low Field Nuclear Magnetic Resonance Spectroscopy. Thus, the purpose of this work is to evaluate collagen and poly(vinylpyrrolidone) by Low Field Nuclear Magnetic Resonance Spectroscopy. From the values of relaxation times obtained, we can conclude that these materials have different interactions, and different mobility domains, confirming the heterogeneity and complexity of these materials. (author)

  10. Optimization of input parameters of supra-threshold stochastic resonance image processing algorithm for the detection of abdomino-pelvic tumors on PET/CT scan

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Saroha, Kartik; Patel, C.D.; Bal, C.S.; Kumar, Rakesh

    2016-01-01

    Administration of diuretics increases the urine output to clear radioactive urine from kidneys and bladder. Hence post-diuretic pelvic PET/CT scan enhances the probability of detection of abdomino-pelvic tumor. However, it causes discomfort in patients and has some side effects also. Application of supra threshold stochastic resonance (SSR) image processing algorithm on Pre-diuretic PET/CT scan may also increase the probability of detection of these tumors. Amount of noise and threshold are two variable parameters that effect the final image quality. This study was conducted to investigate the effect of these two variable parameters on the detection of abdomen-pelvic tumor

  11. Clinically low-risk prostate cancer: evaluation with transrectal doppler ultrasound and functional magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Maria Inês Novis

    2011-01-01

    Full Text Available OBJECTIVES: To evaluate transrectal ultrasound, amplitude Doppler ultrasound, conventional T2-weighted magnetic resonance imaging, spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in localizing and locally staging low-risk prostate cancer. INTRODUCTION: Prostate cancer has been diagnosed at earlier stages and the most accepted classification for low-risk prostate cancer is based on clinical stage T1c or T2a, Gleason score <6, and prostate-specific antigen (PSA <10 ng/ml. METHODS: From 2005 to 2006, magnetic resonance imaging was performed in 42 patients, and transrectal ultrasound in 26 of these patients. Seven patients were excluded from the study. Mean patient age was 64.94 years and mean serum PSA was 6.05 ng/ml. The examinations were analyzed for tumor identification and location in prostate sextants, detection of extracapsular extension, and seminal vesicle invasion, using surgical pathology findings as the gold standard. RESULTS: Sixteen patients (45.7% had pathologically proven organ-confined disease, 11 (31.4% had positive surgical margin, 8 (28.9% had extracapsular extension, and 3 (8.6% presented with extracapsular extension and seminal vesicle invasion. Sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy values for localizing low-risk prostate cancer were 53.1%, 48.3%, 63.4%, 37.8% and 51.3% for transrectal ultrasound; 70.4%, 36.2%, 65.1%, 42.0% and 57.7% for amplitude Doppler ultrasound; 71.5%, 58.9%, 76.6%, 52.4% and 67.1% for magnetic resonance imaging; 70.4%, 58.7%, 78.4%, 48.2% and 66.7% for magnetic resonance spectroscopy; 67.2%, 65.7%, 79.3%, 50.6% and 66.7% for dynamic contrast-enhanced magnetic resonance imaging, respectively. Sensitivity, specificity, PPV, NPV and accuracy values for detecting extracapsular extension were 33.3%, 92%, 14.3%, 97.2% and 89.7% for transrectal ultrasound and 50.0%, 77.6%, 13.7%, 95.6% and 75.7% for magnetic resonance imaging

  12. Evaluation of design parameters in soil-structure systems through artificial intelligence

    International Nuclear Information System (INIS)

    Cremonini, M.G.; Vardanega, C.; Parvis, E.

    1989-01-01

    This study refers to development of an artificial intelligence tool to evaluate design parameters for a soil-structure system as the foundations of Class 1 buildings of a nuclear power plant (NPP). This is based on an expert analysis of a large amount of information, collected during a comprehensive program of site investigations and laboratory tests and stored on a computer data-bank. The methodology comprises the following steps: organization of the available information on the site characteristics in a data-base; implementation and extensive use of a specific knowledge based expert system (KBES) devoted to both the analysis, interpretation and check of the information in the data-base, and to the evaluation of the design parameters; determination of effective access criteria to the data-base, for purposes of reordering the information and extracting design properties from a large number of experimental data; development of design profiles for both index properties and strength/strain parameters; and final evaluation of the design parameters. Results are obtained in the form of: local and general site stratigraphy; summarized soil index properties, detailing the site setting; static and dynamic stress-strain parameters, G/G max behavior and damping factors; condolidation parameters and OCR ratio; spatial distribution of parameters on site area; identification of specific local conditions; and cross correlation of parameters, thus covering the whole range of design parameters for NPP soil-structure systems

  13. Significance of combined nutritional and morphological precaecal parameters for feed evaluations in non-ruminants

    NARCIS (Netherlands)

    Leeuwen, van P.

    2002-01-01

    In this thesis the hypothesis is tested that the nutritional evaluation of dietary formulations in non-ruminants requires both functional-nutritional and functional-morphological parameters. The functional-nutritional parameters provide data on the outcome of the

  14. BUILDING MODEL ANALYSIS APPLICATIONS WITH THE JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY (JUPITER) API

    Science.gov (United States)

    The open-source, public domain JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) API (Application Programming Interface) provides conventions and Fortran-90 modules to develop applications (computer programs) for analyzing process models. The input ...

  15. Evaluation of parameters associated with monitoring in vivo of uranium isotopes in the lungs

    International Nuclear Information System (INIS)

    Juppa, Silvia P.; Lucena, Eder A.; Dantas, Bernardo M.; Dantas, Ana Leticia A.

    2013-01-01

    The objective of this study is to evaluate the parameters associated with the technique of monitoring individuals exposed to uranium isotopes, aiming to optimize the technique and reduced uncertainties associated

  16. Magnetic resonance imaging in the evaluation of treatment in multiple sclerosis

    International Nuclear Information System (INIS)

    Kappos, L.; Staedt, D.; Schneiderbanger-Grygier, S.; Heitzer, T.; Ratzka, M.; Nadjmi, M.; Poser, S.; Keil, W.

    1988-01-01

    Magnetic resonance scans of 74 patients with multiple sclerosis participating in a controlled trial were compared 6 months before and at the end of a 24-32 months-treatment period with either Cyclosporin A (n=31) or Azathioprine (n=43). Both qualitative rating and computation of lesion volume showed deterioration in more than 40% of the patients, while by clinical criteria only 10-30% were worse. No significant difference was noted when the two treatment groups were compared. If careful repositioning and standardized image parameters are used, MRI is an indispensable tool for the objective determination of disease progression in MS although it cannot replace clinical examination. (orig.)

  17. Magnetic resonance imaging in the evaluation of treatment in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Kappos, L.; Staedt, D.; Schneiderbanger-Grygier, S.; Heitzer, T.; Ratzka, M.; Nadjmi, M.; Poser, S.; Keil, W.

    1988-08-01

    Magnetic resonance scans of 74 patients with multiple sclerosis participating in a controlled trial were compared 6 months before and at the end of a 24-32 months-treatment period with either Cyclosporin A (n=31) or Azathioprine (n=43). Both qualitative rating and computation of lesion volume showed deterioration in more than 40% of the patients, while by clinical criteria only 10-30% were worse. No significant difference was noted when the two treatment groups were compared. If careful repositioning and standardized image parameters are used, MRI is an indispensable tool for the objective determination of disease progression in MS although it cannot replace clinical examination.

  18. Evaluation Method for Fieldlike-Torque Efficiency by Modulation of the Resonance Field

    Science.gov (United States)

    Kim, Changsoo; Kim, Dongseuk; Chun, Byong Sun; Moon, Kyoung-Woong; Hwang, Chanyong

    2018-05-01

    The spin Hall effect has attracted a lot of interest in spintronics because it offers the possibility of a faster switching route with an electric current than with a spin-transfer-torque device. Recently, fieldlike spin-orbit torque has been shown to play an important role in the magnetization switching mechanism. However, there is no simple method for observing the fieldlike spin-orbit torque efficiency. We suggest a method for measuring fieldlike spin-orbit torque using a linear change in the resonance field in spectra of direct-current (dc)-tuned spin-torque ferromagnetic resonance. The fieldlike spin-orbit torque efficiency can be obtained in both a macrospin simulation and in experiments by simply subtracting the Oersted field from the shifted amount of resonance field. This method analyzes the effect of fieldlike torque using dc in a normal metal; therefore, only the dc resistivity and the dimensions of each layer are considered in estimating the fieldlike spin-torque efficiency. The evaluation of fieldlike-torque efficiency of a newly emerging material by modulation of the resonance field provides a shortcut in the development of an alternative magnetization switching device.

  19. Perfusion parameters of dynamic contrast-enhanced magnetic resonance imaging in patients with rectal cancer: Correlation with microvascular density and vascular endothelial growth factor expression

    International Nuclear Information System (INIS)

    Kim, Yeo Eun; Lim, Joon Seok; Kim, Myeong Jin; Kim, Ki Whang; Choi, Jun Jeong; Kim, Dae Hong; Myoung, Sung Min

    2013-01-01

    To determine whether quantitative perfusion parameters of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) correlate with immunohistochemical markers of angiogenesis in rectal cancer. Preoperative DCE-MRI was performed in 63 patients with rectal adenocarcinoma. Transendothelial volume transfer (K trans ) and fractional volume of the extravascular-extracellular space (Ve) were measured by Interactive Data Language software in rectal cancer. After surgery, microvessel density (MVD) and vascular endothelial growth factor (VEGF) expression scores were determined using immunohistochemical staining of rectal cancer specimens. Perfusion parameters (K trans , Ve) of DCE-MRI in rectal cancer were found to be correlated with MVD and VEGF expression scores by Spearman's rank coefficient analysis. T stage and N stage (negative or positive) were correlated with perfusion parameters and MVD. Significant correlation was not found between any DCE-MRI perfusion parameters and MVD (rs = -0.056 and p 0.662 for K trans ; rs = -0.103 and p = 0.416 for Ve), or between any DCE-MRI perfusion parameters and the VEGF expression score (rs = -0.042, p 0.741 for K trans ; r = 0.086, p = 0.497 for Ve) in rectal cancer. TN stage showed no significant correlation with perfusion parameters or MVD (p > 0.05 for all). DCE-MRI perfusion parameters, K trans and Ve, correlated poorly with MVD and VEGF expression scores in rectal cancer, suggesting that these parameters do not simply denote static histological vascular properties.

  20. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  1. Voxelwise comparison of perfusion parameters estimated using dynamic contrast enhanced (DCE) computed tomography and DCE-magnetic resonance imaging in locally advanced cervical cancer

    International Nuclear Information System (INIS)

    Kallehauge; Jesper; Nielsen, Thomas; Haack, Soeren

    2013-01-01

    Purpose: Dynamic contrast enhanced (DCE) imaging has gained interest as an imaging modality for assessment of tumor characteristics and response to cancer treatment. However, for DCE-magnetic resonance imaging (MRI) tissue contrast enhancement may vary depending on imaging sequence and temporal resolution. The aim of this study is to compare DCE-MRI to DCE-computed tomography (DCE-CT) as the gold standard. Material and methods: Thirteen patients with advanced cervical cancer were scanned once prior to chemo-radiation and during chemo-radiation with DCE-CT and -MRI in immediate succession. A total of 22 paired DCE-CT and -MRI scans were acquired for comparison. Kinetic modeling using the extended Tofts model was applied to both image series. Furthermore the similarity of the spatial distribution was evaluated using a G analysis. The correlation between the two imaging techniques was evaluated using Pe arson's correlation and the parameter means were compared using a Student's t-test (p trans (r = 0.9), flux rate constant k ep (r = 0.77), extracellular volume fraction v e (r = 0.58) and blood plasma volume fraction v p (r = 0.83). All quantitative parameters were found to be significantly different as estimated by DCE-CT and -MRI. The G analysis in normalized maps revealed that 45 % of the voxels failed to find a voxel with the corresponding value allowing for an uncertainty of 3 mm in position and 3 % in value (G 3,3 ). By reducing the criteria, the G-failure rates were: G 3,5 (37 % failure), G 3,10 (26% failure) and at G 3,15 (19 % failure). Conclusion: Good to excellent correlations but significant bias was found between DCE-CT and -MRI. Both the Pearson's correlation and the G analysis proved that the spatial information was similar when analyzing the two sets of DCE data using the extended Tofts model. Improvement of input function sampling is needed to improve kinetic quantification using DCE-MRI

  2. Evaluation of thermal neutron cross-sections and resonance integrals of protactinium, americium, curium, and berkelium isotopes

    International Nuclear Information System (INIS)

    Belanova, T.S.

    1994-12-01

    Data on the thermal neutron fission and capture cross-sections as well as their corresponding resonance integrals are reviewed and analysed. The data are classified according to the form of neutron spectra under investigation. The weighted mean values of the cross-sections and resonance integrals for every type of neutron spectra were adopted as evaluated data. (author). 87 refs, 2 tabs

  3. Evaluation of the radiation width of the 27.7 keV resonance in 56Fe

    International Nuclear Information System (INIS)

    Allen, B.J.

    1982-01-01

    A critical review is given of measurements of the radiation width of the 27.7 keV resonance in 56 Fe. An evaluation of results yields a recommended value of GAMMA #betta# + 1.00 +- 0.04 eV for this resonance

  4. Evaluation of selected parameters on exposure rates in Westinghouse designed nuclear power plants

    International Nuclear Information System (INIS)

    Bergmann, C.A.

    1989-01-01

    During the past ten years, Westinghouse under EPRI contract and independently, has performed research and evaluation of plant data to define the trends of ex-core component exposure rates and the effects of various parameters on the exposure rates. The effects of the parameters were evaluated using comparative analyses or empirical techniques. This paper updates the information presented at the Fourth Bournemouth Conference and the conclusions obtained from the effects of selected parameters namely, coolant chemistry, physical changes, use of enriched boric acid, and cobalt input on plant exposure rates. The trends of exposure rates and relationship to doses is also presented. (author)

  5. Clinical role of non-contrast magnetic resonance angiography for evaluation of renal artery stenosis

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Nomitsu, Yohei; Komeda, Yosuke; Okigawa, Takashi; Urata, Joji; Miyazaki, Mitsue; Yamashita, Yasuyuki

    2008-01-01

    The association between a gadolinium-based contrast material and nephrogenic systemic fibrosis has been discussed. The purpose of our study was to evaluate whether non-contrast enhanced magnetic resonance angiography (MRA) might provide sufficient information of renal artery stenosis. The non-contrast MRA of 26 patients with hypertension was retrospectively reviewed in the present study. The significant renal artery stenosis was visually evaluated by comparing non-contrast MRA with computed tomography or conventional angiographic finding. Difference of the intensities between the proximal and distal aorta was quantitatively evaluated. The sensitivity, specificity, positive predictive value and negative predictive value of non-contrast MRA in the evaluation of the renal artery stenosis was 78%, 91%, 64% and 96%, respectively. The distal abdominal aorta showed less signal intensity than the proximal aorta by 16.9±12.2%. Non-contrast MRA is a non-invasive and effective method that allows evaluation of the renal artery stenosis. (author)

  6. Carcinomatous involvement of the hilum and mediastinum: computed tomographic and magnetic resonance evaluation

    International Nuclear Information System (INIS)

    Heelan, R.T.; Martini, N.; Westcott, J.W.

    1985-01-01

    Magnetic resonance (MR) imaging and computed tomography (CT) were compared in 20 patients who had primary lung tumors, and the results were correlated with findings at surgery and pathologic evaluation. Both studies demonstrated a similar ability to detect hilar and mediastinal tumor. MR imaging detected more enlarged nodes in the mediastinum, but in several patients these enlarged nodes did not contain tumor. Consequently, MR imaging has a slightly higher false-positive rate in the evaluation of the mediastinum. Both modalities were highly sensitive, with specificity limited by the presence of enlarged benign lymph nodes in this series of patients

  7. Evaluation of some resonance self-shielding procedures employed in high conversion light water reactor design

    International Nuclear Information System (INIS)

    Patino, N.E.; Abbate, M.J.; Sbaffoni, M.M.

    1990-01-01

    The procedures employed in the treatment of the resonance shielding effect have been identified as one of the causes of the large discrepancies found in the neutronic calculation of high conversion light water reactors (HCLWRs), indicating the need for a revision of the self-shielding procedures employed. In this work some well known techniques applied in HCLWR self-shielding calculations are evaluated; the study involves the comparison of methods for the generation of group constants, the analysis of the impact of considering some isotopes as infinitely diluted and the evaluation of the usual approximations utilized for the treatment of heterogeneities

  8. Testing of Alignment Parameters for Ancient Samples: Evaluating and Optimizing Mapping Parameters for Ancient Samples Using the TAPAS Tool

    Directory of Open Access Journals (Sweden)

    Ulrike H. Taron

    2018-03-01

    Full Text Available High-throughput sequence data retrieved from ancient or other degraded samples has led to unprecedented insights into the evolutionary history of many species, but the analysis of such sequences also poses specific computational challenges. The most commonly used approach involves mapping sequence reads to a reference genome. However, this process becomes increasingly challenging with an elevated genetic distance between target and reference or with the presence of contaminant sequences with high sequence similarity to the target species. The evaluation and testing of mapping efficiency and stringency are thus paramount for the reliable identification and analysis of ancient sequences. In this paper, we present ‘TAPAS’, (Testing of Alignment Parameters for Ancient Samples, a computational tool that enables the systematic testing of mapping tools for ancient data by simulating sequence data reflecting the properties of an ancient dataset and performing test runs using the mapping software and parameter settings of interest. We showcase TAPAS by using it to assess and improve mapping strategy for a degraded sample from a banded linsang (Prionodon linsang, for which no closely related reference is currently available. This enables a 1.8-fold increase of the number of mapped reads without sacrificing mapping specificity. The increase of mapped reads effectively reduces the need for additional sequencing, thus making more economical use of time, resources, and sample material.

  9. An evaluation of magnetic resonance imaging at the Royal North Shore Hospital of Sydney, 1986-1987

    International Nuclear Information System (INIS)

    Sorby, W.A.

    1989-01-01

    The diagnostic accuracy and clinical utility have been evaluated of 2810 consecutive magnetic-resonance-imaging examinations that were performed on a 1.5-T Signa magnetic-resonance-imaging unit at The Royal North Shore Hospital of Sydney between November 1986 and December 1987. The average accuracy of magnetic resonance imaging was 80%, and ranged from 21%-98% in various brain-disease and spinal-disease categories, compared with the average provisional premagnetic-resonance-imaging diagnostic accuracy of 64%, and an average accuracy of computed tomography of 45%. Clinical follow-up at three months after magnetic-resonance-imaging investigation indicated that, as a result of the magnetic-resonance-imaging examination, patient management was altered in 70% of cases, and patient outcome was altered in 62% of cases. 32 refs., 4 tabs

  10. An improved broadband method to evaluate effective parameters of slab metamaterials in the microwave frequency range

    International Nuclear Information System (INIS)

    Rybin, O.; Nawaz, T.; Abbasi, T.

    2007-01-01

    An improved broadband method for determining complex effective refractive index, permittivity and permeability of an arbitrary passive metamaterial in microwave frequency range has been proposed. Evaluation of the effective parameters is realized using the reflection-transmission S-parameters obtained by simulation or experimental measurements and analytically evaluated interface reflection coefficient of the slab. Formulas for evaluation of effective permittivity and permeability which contain the square root of complex functions of S-parameters have been proposed in (1-2). But this method does not propose a way to avoid an ambiguity arising in choosing the square root branch of product of effective permittivity and permeability. Moreover the above calculation procedure requires evaluating the square root branch of function of S-parameters. Proposed way to choose the square root branch gives sometimes mistaken results. Our method is much simple as compared with the above mentioned formulas and it does not require making a choice of square root branch of complex functions of S-parameters in order to evaluate any of the parameters (refractive index, permittivity or permeability). Instead we obtain a formula for complex refractive index which is simple. On the basis of proposed model effective permittivity and permeability for rod meta-materials can be evaluated with enhanced precision and accuracy. Proposed method is easy to be implemented in engineering problems and does not require using complicated mathematical calculations. Comparison of precision of the presented method with the Nicolson-Ross techniques (1-2) has been made using the simulations for different configurations of rod meta-materials. Some discussion concerning the sensitivity of the effective parameters of meta-materials for the accuracy of the frequency dependent S -parameters is also presented in this paper. (author)

  11. Evaluation of toroidal torque by non-resonant magnetic perturbations in tokamaks for resonant transport regimes using a Hamiltonian approach

    Energy Technology Data Exchange (ETDEWEB)

    Albert, Christopher G.; Heyn, Martin F.; Kapper, Gernot; Kernbichler, Winfried; Martitsch, Andreas F. [Fusion@ÖAW, Institut für Theoretische Physik - Computational Physics, Technische Universität Graz, Petersgasse 16, 8010 Graz (Austria); Kasilov, Sergei V. [Fusion@ÖAW, Institut für Theoretische Physik - Computational Physics, Technische Universität Graz, Petersgasse 16, 8010 Graz (Austria); Institute of Plasma Physics, National Science Center “Kharkov Institute of Physics and Technology,” ul. Akademicheskaya 1, 61108 Kharkov (Ukraine)

    2016-08-15

    Toroidal torque generated by neoclassical viscosity caused by external non-resonant, non-axisymmetric perturbations has a significant influence on toroidal plasma rotation in tokamaks. In this article, a derivation for the expressions of toroidal torque and radial transport in resonant regimes is provided within quasilinear theory in canonical action-angle variables. The proposed approach treats all low-collisional quasilinear resonant neoclassical toroidal viscosity regimes including superbanana-plateau and drift-orbit resonances in a unified way and allows for magnetic drift in all regimes. It is valid for perturbations on toroidally symmetric flux surfaces of the unperturbed equilibrium without specific assumptions on geometry or aspect ratio. The resulting expressions are shown to match the existing analytical results in the large aspect ratio limit. Numerical results from the newly developed code NEO-RT are compared to calculations by the quasilinear version of the code NEO-2 at low collisionalities. The importance of the magnetic shear term in the magnetic drift frequency and a significant effect of the magnetic drift on drift-orbit resonances are demonstrated.

  12. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  13. Sensitivity Analysis of Depletion Parameters for Heat Load Evaluation of PWR Spent Fuel Storage Pool

    International Nuclear Information System (INIS)

    Kim, In Young; Lee, Un Chul

    2011-01-01

    As necessity of safety re-evaluation for spent fuel storage facility has emphasized after the Fukushima accident, accuracy improvement of heat load evaluation has become more important to acquire reliable thermal-hydraulic evaluation results. As groundwork, parametric and sensitivity analyses of various storage conditions for Kori Unit 4 spent fuel storage pool and spent fuel depletion parameters such as axial burnup effect, operation history, and specific heat are conducted using ORIGEN2 code. According to heat load evaluation and parametric sensitivity analyses, decay heat of last discharged fuel comprises maximum 80.42% of total heat load of storage facility and there is a negative correlation between effect of depletion parameters and cooling period. It is determined that specific heat is most influential parameter and operation history is secondly influential parameter. And decay heat of just discharged fuel is varied from 0.34 to 1.66 times of average value and decay heat of 1 year cooled fuel is varied from 0.55 to 1.37 times of average value in accordance with change of specific power. Namely depletion parameters can cause large variation in decay heat calculation of short-term cooled fuel. Therefore application of real operation data instead of user selection value is needed to improve evaluation accuracy. It is expected that these results could be used to improve accuracy of heat load assessment and evaluate uncertainty of calculated heat load.

  14. Evaluation of tomographic ISOCAM Park II gamma camera parameters using Monte Carlo method

    International Nuclear Information System (INIS)

    Oramas Polo, Ivón

    2015-01-01

    In this paper the evaluation of tomographic ISOCAM Park II gamma camera parameters was performed using the Monte Carlo code SIMIND. The parameters uniformity, resolution and contrast were evaluated by Jaszczak phantom simulation. In addition the qualitative assessment of the center of rotation was performed. The results of the simulation are compared and evaluated against the specifications of the manufacturer of the gamma camera and taking into account the National Protocol for Quality Control of Nuclear Medicine Instruments of the Cuban Medical Equipment Control Center. A computational Jaszczak phantom model with three different distributions of activity was obtained. They can be used to perform studies with gamma cameras. (author)

  15. Evaluation of ECG criteria for left ventricular hypertrophy before and after aortic valve replacement using magnetic resonance Imaging

    NARCIS (Netherlands)

    Beyerbacht, Hugo P.; Bax, Jeroen J.; Lamb, Hildo J.; van der Laarse, Arnoud; Vliegen, Hubert W.; de Roos, Albert; Zwinderman, Aeilko H.; van der Wall, Ernst E.

    2003-01-01

    PURPOSE: Evaluation of different electrocardiographic criteria for left ventricular hypertrophy (ECG-LVH criteria) using left ventricular mass index (LVMI) determined by magnetic resonance imaging (MRI). In addition, the relation between LVMI regression after aortic valve replacement and

  16. Microstrip resonators for electron paramagnetic resonance experiments

    Science.gov (United States)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  17. Microstrip resonators for electron paramagnetic resonance experiments.

    Science.gov (United States)

    Torrezan, A C; Mayer Alegre, T P; Medeiros-Ribeiro, G

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5 x 10(10) spins/GHz(1/2) despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  18. Photon energy dependence of left-right asymmetry parameters of Kr 4p photoelectrons in the vicinity of 3d resonant excitations

    International Nuclear Information System (INIS)

    Ricz, S.; Holste, K.; Borovik, Jr.A.A.; Bernhardt, D.; Schippers, S.; Muller, A.; Kover, A.; Varga, D.

    2011-01-01

    Complete text of publication follows. A left-right asymmetry was observed experimentally for the outer s-shell photoelectrons of noble gases and of the H 2 molecule in our previous studies (see the cited articles for the definition of 'left' and 'right' as well as for the details of the experimental method). Recently, the angular distribution of 4p photoelectrons of Kr was measured with linearly polarized synchrotron radiation in the photon energy range (90 - 94.4 eV) of the 3d -1 → np resonant excitations in order to determine the anisotropy parameters. Now, also the left-right asymmetry parameters have been determined from the measured spectra of Ref. [3]. The experiment was performed at beamline BW3 of the DORIS III storage ring at HASYLAB (Hamburg, Germany). The emitted electrons were analyzed using the ESA-22D electrostatic electron spectrometer. Fig. 1 shows the measured left-right asymmetry parameters (A LR ) of the two fine structure components of Kr 4p photoelectrons. The asymmetry parameters (A LR ) are increasing with increasing photon energies reaching a maximum value of 0.04, definitely different from zero when considering the error bars. Furthermore, the left-right asymmetry parameters oscillate around the (3d 3/2,5/2 ) -1 → 5p resonant excitation for both fine structure components. Currently, we do not know what kind of interaction can produce a left-right asymmetry in photon-atom collisions but the shape of the oscillations shows interference between the unknown and the resonant excitation channels. One of the most important observations is that the sign of A LR changes from positive to negative and then back again to positive just within a narrow photon energy range of only 250 meV around the (3d 5/2 ) -1 → 5p resonant excitation. Within such a narrow range artificial asymmetry of the experimental setup is totally unconceivable. Acknowledgements. The authors thank the DORIS III staff for providing excellent working conditions. This work was

  19. Continuous administration of short-lived isotopes for evaluating dynamic parameters

    International Nuclear Information System (INIS)

    Selikson, M.

    1985-01-01

    In this paper it is shown that continuous but varying infusions (specifically, exponential infusions) of a short-lived radionuclide can be used to evaluate a wide range of dynamic parameters. The detector response to exponential infusions is derived. An example of an inert diffusible substrate for evaluating regional flow and a glucose model for evaluating regional metabolic rate are both worked out. The advantages of using exponential infusion methods are discussed

  20. Magnetic resonance imaging of sella turcica: evaluation of patients with galactorrhea, amenorrhea and hyperprolactinemia

    International Nuclear Information System (INIS)

    Santos, Alair Augusto Sarmet M.D. dos; Moreira, Denise Madeira; Andreiuolo, Pedro Angelo

    1999-01-01

    We have selected 135 cases of patients who have done magnetic resonance imaging of sella region, carried out from September, 1991 to August, 1996, who had galactorrhea (G), amenorrhea(A), and hyperprolactinemia (H), isolated or in association. The patients were divided in seven groups, according to the presence of these symptoms and signs. All examinations were made in a private clinic in the city of Rio de Janeiro, Brazil. Correlating these patients with the results of the magnetic resonance images, we found 57 micro adenomas, 31 normal examinations, 22 macro adenomas, 11 pituitary hyperplasias, 7 empty sella and 7 cases included in other aspects. The micro adenoma predominated in groups 1 (GAH), 2 (GH), 3 (HA) and 5 (H), that is, in all groups whose patients had hyperprolactinemia. In macro adenomas, a bright signal on T 1-weighted images indicates pituitary apoplexy with intratumoral hemorrhage. All in all, the magnetic resonance imaging is excellent method to be used in the evaluation of patients with changes in the hypothalamic-pituitary axis. (author)

  1. Effects of electromagnetic radiation produced by 3G mobile phones on rat brains: magnetic resonance spectroscopy, biochemical, and histopathological evaluation.

    Science.gov (United States)

    Dogan, M; Turtay, M G; Oguzturk, H; Samdanci, E; Turkoz, Y; Tasdemir, S; Alkan, A; Bakir, S

    2012-06-01

    The effects of electromagnetic radiation (EMR) produced by a third-generation (3G) mobile phone (MP) on rat brain tissues were investigated in terms of magnetic resonance spectroscopy (MRS), biochemistry, and histopathological evaluations. The rats were randomly assigned to two groups: Group 1 is composed of 3G-EMR-exposed rats (n = 9) and Group 2 is the control group (n = 9). The first group was subjected to EMR for 20 days. The control group was not exposed to EMR. Choline (Cho), creatinin (Cr), and N-acetylaspartate (NAA) levels were evaluated by MRS. Catalase (CAT) and glutathione peroxidase (GSH-Px) enzyme activities were measured by spectrophotometric method. Histopathological analyses were carried out to evaluate apoptosis in the brain tissues of both groups. In MRS, NAA/Cr, Cho/Cr, and NAA/Cho ratios were not significantly different between Groups 1 and 2. Neither the oxidative stress parameters, CAT and GSH-Px, nor the number of apoptotic cells were significantly different between Groups 1 and 2. Usage of short-term 3G MP does not seem to have a harmful effect on rat brain tissue.

  2. The evaluation on clamping force of high strength bolts by length parameter

    International Nuclear Information System (INIS)

    Kim, Kang-Seok; Nah, Hwan-Seon; Lee, Hyeon-Ju; Lee, Kang-Min

    2009-01-01

    It has been reported that the length parameter of high strength bolts results in the variance in tension loads. The required turn for each length is specified in AISC RCSC specification. This study was focused on evaluating any influence on the clamping torque subjected to length parameter of high strength bolts. The two kinds of high strength bolts of specimen are as follows; High Strength Hexagon bolt defined on ASTM A490 and Torque Shear Bolt on KS B 2819. The length parameter ranged from 60mm(3d) to 140mm(7d). The torque, turn of nut and the clamping force were analyzed to review whether length parameter can be affected on the required tension load. To test whether the length parameter has an impact on the torque and turn of nut for the required strength and clamping force, statistical analysis is carried out. (author)

  3. Non-Destructive Evaluation of Kissing Bonds using Local Defect Resonance (LDR) Spectroscopy: A Simulation Study

    Science.gov (United States)

    Delrue, S.; Tabatabaeipour, M.; Hettler, J.; Van Den Abeele, K.

    With the growing demand from industry to optimize and further develop existing Non-Destructive Testing & Evaluation (NDT&E) techniques or new methods to detect and characterize incipient damage with high sensitivity and increased quality, ample efforts have been devoted to better understand the typical behavior of kissing bonds, such as delaminations and cracks. Recently, it has been shown experimentally that the nonlinear ultrasonic response of kissing bonds could be enhanced by using Local Defect Resonance (LDR) spectroscopy. LDR spectroscopy is an efficient NDT technique that takes advantage of the characteristic fre- quencies of the defect (defect resonances) in order to provide maximum acoustic wave-defect interaction. In fact, for nonlinear methodologies, the ultrasonic excitation of the sample should occur at either multiples or integer ratios of the characteristic defect resonance frequencies, in order to obtain the highest signal-to-noise response in the nonlinear LDR spectroscopy. In this paper, the potential of using LDR spectroscopy for the detection, localization and characterization of kissing bonds is illustrated using a 3D simulation code for elastic wave propagation in materials containing closed but dynamically active cracks or delaminations. Using the model, we are able to define an appropriate method, based on the Scaling Subtraction Method (SSM), to determine the local defect resonance frequencies of a delamination in a composite plate and to illustrate an increase in defect nonlinearity due to LDR. The simulation results will help us to obtain a better understanding of the concept of LDR and to assist in the further design and testing of LDR spectroscopy for the detection, localization and characterization of kissing bonds.

  4. Cardiac magnetic resonance imaging for evaluation of non-compaction cardiomyopathy in patients with or without left ventricular systolic dysfunction

    International Nuclear Information System (INIS)

    Deviggiano, A.; Deschle, H.; Lewkowicz, J.M.; Tajer, C.D.; Carrascosa, P.; Capunay, C.; Vallejos, J.; Stewart Harris, A.

    2011-01-01

    Background: Non-compaction cardiomyopathy (NCC) is a genetic disorder characterized by deep trabeculations in the ventricular wall, which define recesses communicating with the main ventricular chamber. The prevalence of NCC is greater in symptomatic populations with left ventricular dysfunction; yet, it may also be detected in asymptomatic patients with normal left ventricular function using novel diagnostic tools. However, this condition is under-diagnosed due to a low index of clinical suspicion and to the use of echocardiography classifications based on different diagnostic criteria. The use of cardiac magnetic resonance imaging (CMRI) has established two diagnostic criteria that clearly recognize this disease. Objective: To evaluate the clinical and morphological characteristics of patients with NCC with and without systolic dysfunction undergoing cardiac magnetic resonance imaging (CMRI). Material and Methods: A total of 20 patients with NCC were retrospectively included. The following parameters were determined: left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV); left ventricular end-diastolic diameter (LVEDD); left ventricular end-systolic diameter (LVESD); cardiac mass and left ventricular trabeculations. The distribution of NC myocardium was evaluated according to the model of 17 myocardial segments. Results: Mean myocardial thickness was 13.1 ± 3.3 mm and 3.6 ± 0.6 mm in NC versus normal myocardium, respectively. Patients with left ventricular dysfunction presented increased LVEDD, LVEDV, total cardiac mass, and LV non-compaction and trabeculations. We found a positive correlation and a linear relationship between LVEDD and TLVM (g/m 2 ): r=0.76; r 2 =0.59; p [es

  5. Acromioclavicular dislocation: postoperative evaluation of the coracoclavicular ligaments using magnetic resonance

    Directory of Open Access Journals (Sweden)

    Rafael Salomon Silva Faria

    2015-04-01

    Full Text Available OBJECTIVE: To radiologically evaluate the healing of the coracoclavicular ligaments after surgical treatment for acromioclavicular dislocation.METHODS: Ten patients who had undergone surgical treatment for acromioclavicular dislocation via a posterosuperior route at least one year earlier were invited to return for radiological assessment using magnetic resonance. This evaluation was done by means of analogy with the scale described in the literature for studying the healing of the anterior cruciate ligament of the knee and for measuring the healed coracoclavicular ligaments.RESULTS: A scar structure of fibrous appearance had formed in 100% of the cases. In 50% of the cases, the images of this structure had a good appearance, while the other 50% were deficient.CONCLUSION: Late postoperative evaluation using magnetic resonance, on patients who had been treated for acute acromioclavicular dislocation using a posterosuperior route in the shoulder, showed that the coracoclavicular ligaments had healed in 100% of the cases, but that this healing was deficient in 50%.

  6. Cine-magnetic resonance imaging evaluation of communication between middle cranial fossa arachnoid cysts and cisterns

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Shiomi, Kazuaki; Fujimoto, Takatoshi; Otsuka, Hiroyuki; Takeuchi, Hiroshi; Taoka, Toshiaki.

    1996-01-01

    Cine-magnetic resonance (MR) imaging examinations were performed in 10 patients with middle cranial fossa arachnoid cysts to evaluate communication between the cysts and the normal cerebrospinal fluid (CSF) space. Eight of 10 patients were evaluated by time of flight cine-MR imaging, and two by phase contrast cine-MR imaging. Two patients underwent membranectomy of the cysts, and were evaluated both pre-and postoperatively. Computed tomography cisternography was used to confirm communication between the cysts and the surrounding cisterns. Pulsatile fluid motion within the cysts was present in all patients. However, marked fluid motion and jet flow between the cysts and the surrounding cisterns were only observed in communicating cysts. In the two patients who underwent membranectomy, postoperative examination found greater fluid motion and jet flow not previously present. Cine-MR imaging demonstration of marked pulsatile fluid motion accompanied by jet flow suggests that a cyst communicates with the normal CSF space. (author)

  7. Contrast-enhanced magnetic resonance angiography: evaluation of renal arteries in living renal transplant donors

    International Nuclear Information System (INIS)

    Firat, Ali; Akin, Oguz; Muhtesem Agildere, Ahmet; Aytekin, Cuneyt; Haberal, Mehmet

    2004-01-01

    One of the most important steps before living-donor nephrectomy is assessment of renal vascular anatomy. The number, origins and lengths of the renal arteries and variations of renal veins must be determined in order to identify the kidney that is most suitable for transplantation. Digital subtraction angiography was long considered the standard procedure for this purpose, but this method has been replaced by non-invasive techniques. Contrast-enhanced magnetic resonance angiography is an accurate, safe and reliable method for imaging vasculature. This article reviews the technique and the clinical features of this method in the evaluation of living renal transplant donors

  8. Magnetic resonance imaging evaluation of traumatic muscle injuries; Avaliacao por ressonancia magnetica das injurias musculares traumaticas

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Elisa Pompeu [Santa Casa de Misericordia do Rio de Janeiro, RJ (Brazil); Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Coutinho Junior, Antonio Carlos; Domingues, Romulo Cortes; Domingues, Romeu Cortes [Centro Medico Barrashopping, Rio de Janeiro, RJ (Brazil). Clinica de Diagnostico por Imagem (CDPI)

    2001-12-01

    We evaluated 43 magnetic resonance scans of the leg or thigh of patients suffering from sports trauma. Strains were the most frequent lesions observed. These lesions presented iso- or hypointense signal on T1 and hyperintense signal on T2 images, and were classified according to the intensity of the injury of the fibers into grades 1, 2 and 3. The second most common lesions in these series were contusions that appeared iso- or hypointense on T1 and hyperintense on T2 images. Fibrosis was also observed as low signal lesions on T1 and T2 images. (author)

  9. Magnetic resonance imaging (MRI) evaluation of residual breast tissue following mastectomy and reconstruction with silicone implants.

    Science.gov (United States)

    Zippel, Douglas; Tsehmaister-Abitbol, Vered; Rundstein, Arie; Shalmon, Anat; Zbar, Andrew; Nardini, Gil; Novikov, Ilya; Sklair-Levy, Miri

    2015-01-01

    We present our use of magnetic resonance (MR) measurement to determine the amount of residual breast tissue (RBT) following total mastectomy with reconstruction. Breast MR images of 45 women who underwent surgery between January and November 2011 were reviewed. The cohort included therapeutic and prophylactic mastectomies. RBT was evaluated at four points with a digital caliper assessing T2-weighted and T1-weighted images. Patients undergoing mastectomy for carcinoma tended to have less RBT than in prophylactic surgery. Greater age and recent surgery both correlated with larger RBT. Variable thickness of RBT is demonstrable following mastectomy and implant reconstruction using MR imaging. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Evaluation of biexponential relaxation processes by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Larsson, H B

    1988-01-01

    Despite the complexity of biologic tissues, a monoexponential behaviour is usually assumed when estimating relaxation processes in vivo by magnetic resonance imaging (MRI). This study was designed to evaluate the potential of biexponential decomposition of T1 and T2 relaxation curves obtained at 1...... echoes. Applying biexponential curve analysis, a significant deviation from a monoexponential behaviour was recognized at a ratio of corresponding relaxation rates of about 3 and 2, estimating T1 and T2 relaxation, respectively (p less than 0.01, F-test). Requiring an SD less than or equal to 10 per cent...

  11. Contrast-enhanced magnetic resonance angiography: evaluation of renal arteries in living renal transplant donors

    Energy Technology Data Exchange (ETDEWEB)

    Firat, Ali; Akin, Oguz; Muhtesem Agildere, Ahmet; Aytekin, Cuneyt; Haberal, Mehmet

    2004-10-01

    One of the most important steps before living-donor nephrectomy is assessment of renal vascular anatomy. The number, origins and lengths of the renal arteries and variations of renal veins must be determined in order to identify the kidney that is most suitable for transplantation. Digital subtraction angiography was long considered the standard procedure for this purpose, but this method has been replaced by non-invasive techniques. Contrast-enhanced magnetic resonance angiography is an accurate, safe and reliable method for imaging vasculature. This article reviews the technique and the clinical features of this method in the evaluation of living renal transplant donors.

  12. Long term evaluation of brain perfusion with magnetic resonance in high flow extracranial-intracranial saphenous graft bypass

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro [University of Rome La Sapienza, Department of Neuroradiology, II Faculty of Medicine, Rome (Italy); Sant' Andrea Hospital, Rome (Italy); Fasoli, Fabrizio; Finocchi, Vanina; Romano, Andrea; Fantozzi, Luigi M. [University of Rome La Sapienza, Department of Neuroradiology, II Faculty of Medicine, Rome (Italy); Santoro, Giuseppe [University of Rome La Sapienza, Department of Neurosurgery, I Faculty of Medicine, Rome (Italy)

    2007-01-15

    Assessment was made of the cerebral vascular haemodynamic parameters in patients with a high-flow extra-intracranial (EC-IC) bypass performed for therapeutic occlusion of the internal carotid artery (ICA). Sixteen patients with ICA occlusion and EC-IC bypass (time interval from surgery 1-6 years) underwent MRI. Perfusion-weighted magnetic resonance imaging (PW-MRI) sequences were performed without the use of an arterial input function. The relative cerebral blood volume (rCBV), mean transit time (MTT) and relative cerebral blood flow (rCBF) were evaluated in all patients at the level of the basal ganglia, centrum semiovale and cortex in both hemispheres. Statistically significant differences (P<0.005) were observed in the haemodynamic parameters, indicating increased rCBV in the basal ganglia and decreased rCBF and rCBV in the cortex of the hemisphere supplied by the graft with respect to the contralateral. Patients with occlusion of the ICA and high flow EC-IC bypass do have altered vascular haemodynamic status between the hemispheres. In particular, rCBF is impaired in the surgical hemisphere at the level of the cortex. These patients should be followed-up to rule out chronic ischemia. (orig.)

  13. RAHAB calculation of lattice parameters for CANDU-type lattices using Monte Carlo calculations for resolved resonance capture

    International Nuclear Information System (INIS)

    Craig, D.S.; Festarini, G.L.

    1986-07-01

    The Monte Carlo code, REPC, has been used to calculate resonance reaction rates for the thermal test lattices TRX-1 and MIT-4, and for the CRNL lattices ZEEP-1, 19 UO 2 and 37 UO 2 . These reaction rates were used in the RAHAB cell code to calculate k eff , conversion ratios, and fast fission ratios, for comparison with experimental values. The calculations used the cluster geometry for the 19-, 28-, and 37-element clusters. Calculations were also made using annular representations of the cluster for comparison of the rates with those obtained using the discrete ordinate code OZMA

  14. Evaluation of acoustic resonance at branch section in main steam line. Part 2. Proposal of method for predicting resonance frequency in steam flow

    International Nuclear Information System (INIS)

    Uchiyama, Yuta; Morita, Ryo

    2012-01-01

    Flow-induced acoustic resonances of piping system containing closed side-branches are sometimes encountered in power plants. Acoustic standing waves with large amplitude pressure fluctuation in closed side-branches are excited by the unstable shear layer which separates the mean flow in the main piping from the stagnant fluid in the branch. In U.S. NPP, the steam dryer had been damaged by high cycle fatigue due to acoustic-induced vibration under a power uprating condition. Our previous research developed the method for evaluating the acoustic resonance at the branch sections in actual power plants by using CFD. In the method, sound speed in wet steam is evaluated by its theory on the assumption of homogeneous flow, although it may be different from practical sound speed in wet steam. So, it is necessary to consider and introduce the most suitable model of practical sound speed in wet steam. In addition, we tried to develop simplified prediction method of the amplitude and frequency of pressure fluctuation in wet steam flow. Our previous experimental research clarified that resonance amplitude of fluctuating pressure at the top of the branch in wet steam. However, the resonance frequency in steam condition could not be estimated by using theoretical equation as the end correction in steam condition and sound speed in wet steam is not clarified as same reason as CFD. Therefore, in this study, we tried to evaluate the end correction in each dry and wet steam and sound speed of wet steam from experimental results. As a result, method for predicting resonance frequency by using theoretical equation in each wet and dry steam condition was proposed. (author)

  15. Evaluation of the parameters effects on the bio-ethanol production process from Ricotta Cheese Whey

    DEFF Research Database (Denmark)

    Sansonetti, Sascha; Curcio, Stefano; Calabrò, Vincenza

    2010-01-01

    composite design, constituted by 26 runs, has been carried out, and the effects of the parameters have been evaluated. Eventually, once eliminated the negligible effects, Response Surface Methodology (RSM) has been applied to optimize the four parameters values in RCW fermentation process. After......The work consists of an experimental analysis to evaluate the effects of the variables temperature (T), pH, agitation rate (K) and initial lactose concentration (L) on the batch fermentation process of Ricotta Cheese Whey (RCW) into bio-ethanol by using the yeast Kluyveromyces marxianus. A central...

  16. The role of magnetic resonance imaging in the evaluation of transfusional iron overload in myelodysplastic syndromes.

    Science.gov (United States)

    Petrou, Emmanouil; Mavrogeni, Sophie; Karali, Vasiliki; Kolovou, Genovefa; Kyrtsonis, Marie-Christine; Sfikakis, Petros P; Panayiotidis, Panayiotis

    2015-01-01

    Myelodysplastic syndromes represent a group of heterogeneous hematopoietic neoplasms derived from an abnormal multipotent progenitor cell, characterized by a hyperproliferative bone marrow, dysplasia of the cellular hemopoietic elements and ineffective erythropoiesis. Anemia is a common finding in myelodysplastic syndrome patients, and blood transfusions are the only therapeutic option in approximately 40% of cases. The most serious side effect of regular blood transfusion is iron overload. Currently, cardiovascular magnetic resonance using T2 is routinely used to identify patients with myocardial iron overload and to guide chelation therapy, tailored to prevent iron toxicity in the heart. This is a major validated non-invasive measure of myocardial iron overloading and is superior to surrogates such as serum ferritin, liver iron, ventricular ejection fraction and tissue Doppler parameters. The indication for iron chelation therapy in myelodysplastic syndrome patients is currently controversial. However, cardiovascular magnetic resonance may offer an excellent non-invasive, diagnostic tool for iron overload assessment in myelodysplastic syndromes. Further studies are needed to establish the precise indications of chelation therapy and the clinical implications of this treatment on survival in myelodysplastic syndromes. Copyright © 2014 Associação Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. All rights reserved.

  17. Systolic function evaluated with cardiovascular magnetic resonance imaging in HIV-infected patients

    Directory of Open Access Journals (Sweden)

    Leonie Scholtz

    2016-11-01

    Objectives: To ascertain whether there were any morphological abnormalities or systolic functional impairments on CMR in untreated asymptomatic HIV-infected patients, compared with HIV-uninfected control individuals. Methods: The CMR studies were performed using a 1.5-T whole-body clinical magnetic resonance 16-channel scanner (Achieva, Philips Medical Systems, Best, The Netherlands, using a cardiac five-element phased-array receiver coil (SENSE coil. Functional assessment was performed on 36 HIV-infected patients and the findings compared with 35 HIV-uninfected control patients who were matched for age and sex. Results: There was no significant difference in systolic function between the HIV-uninfected and the HIV-infected patients. The left ventricular end diastolic mass (LVEDM was slightly higher in the HIV-infected group, but this was statistically insignificant. Conclusion: No significant differences were found regarding the CMR systolic functional analysis and morphological parameters between the HIV-infected and the healthy volunteers.

  18. Briquetting of coal fines and sawdust. Part 1: binder and briquetting-parameters evaluations

    Energy Technology Data Exchange (ETDEWEB)

    D. Taulbee; D.P. Patil; Rick Q. Honaker; B.K. Parekh [University of Kentucky, Lexington, KY (United States). Center for Applied Energy Research

    2009-01-15

    Various technical and economic aspects relating to the briquetting of fine coal with sawdust have been evaluated with the results for two segments of that study presented here: binder and briquetting-parameter evaluations. Approximately 50 potential binder formulations were subjected to a series of screening evaluations to identify three formulations that were the most cost effective for briquetting fine coal with sawdust. Two of the binders, guar gum and wheat starch, were selected as most suitable for the pulverized coal market while the third formulation, lignosulfonate/lime, was targeted for the stoker market. Following binder selection, a number of briquetting parameters including binder and sawdust concentration, sawdust type, briquetting pressure and dwell time, coal and sawdust particle size, clay content, moisture content, and cure temperature and cure time were evaluated. Briquetting pressure and dwell time have the least impact while binder and sawdust concentrations, sawdust type, and curing conditions exerted the greatest influence on briquette quality. 7 refs.

  19. An efficient method for evaluating the effect of input parameters on the integrity of safety systems

    International Nuclear Information System (INIS)

    Tang, Zhang-Chun; Zuo, Ming J.; Xiao, Ningcong

    2016-01-01

    Safety systems are significant to reduce or prevent risk from potentially dangerous activities in industry. Probability of failure to perform its functions on demand (PFD) for safety system usually exhibits variation due to the epistemic uncertainty associated with various input parameters. This paper uses the complementary cumulative distribution function of the PFD to define the exceedance probability (EP) that the PFD of the system is larger than the designed value. Sensitivity analysis of safety system is further investigated, which focuses on the effect of the variance of an individual input parameter on the EP resulting from epistemic uncertainty associated with the input parameters. An available numerical technique called finite difference method is first employed to evaluate the effect, which requires extensive computational cost and needs to select a step size. To address these difficulties, this paper proposes an efficient simulation method to estimate the effect. The proposed method needs only an evaluation to estimate the effects corresponding to all input parameters. Two examples are used to demonstrate that the proposed method can obtain more accurate results with less computation time compared to reported methods. - Highlights: • We define a sensitivity index to measure effect of a parameter for safety system. • We analyze the physical meaning of the sensitivity index. • We propose an efficient simulation method to assess the sensitivity index. • We derive the formulations of this index for lognormal and beta distributions. • Results identify important parameters on exceedance probability of safety system.

  20. Magnetic resonance imaging in the evaluation of treatment response of lateral epicondylitis of the elbow

    International Nuclear Information System (INIS)

    Savnik, Anette; Jensen, Bente; Noerregaard, Jesper; Danneskiold-Samsoee, Bente; Bliddal, Henning; Egund, Niels

    2004-01-01

    The purpose of this study was to investigate the treatment response in lateral epicondylitis (tennis elbow) by MRI. Magnetic resonance imaging was obtained in 30 patients with clinical symptoms of lateral epicondylitis of the elbow using T1-, T2- and T2-weighted fat-saturated (FS) sequences. The patients were randomised to either i.m. corticosteroid injection (n=16) or immobilisation in a wrist splint (n=14). Magnetic resonance imaging of the elbow was performed on a 1.5-T MR system at baseline and after 6 weeks. The extensor carpi radialis (ECRB) tendon, the radial collateral ligament, lateral humerus epicondyle at tendon insertion site, joint fluid and signal intensity changes within brachio-radialis and anconeus muscles were evaluated on the MR unit's workstation before and after 6 weeks of treatment. The MRI was performed once in 22 healthy controls for comparison and all images evaluated by an investigator blinded to the clinical status of the subjects. The MR images showed thickening with separation of the ECRB tendon from the radial collateral ligament and abnormal signal change in 25 of the 30 patients on the T1-weighted sequences at inclusion. The signal intensity of the ECRB tendon was increased in 24 of the 30 patients with lateral epicondylitis of the elbow on the T2-weighted FS sequences. (orig.)

  1. Magnetic resonance imaging in the evaluation of treatment response of lateral epicondylitis of the elbow

    Energy Technology Data Exchange (ETDEWEB)

    Savnik, Anette [Parker Institute, Frederiksberg Hospital, Nordre Fasanvej 57, 2000, Frederiksberg (Denmark); Department of Radiology, Frederiksberg Hospital, Nordre Fasanvej 57, 2000, Frederiksberg (Denmark); Hovmarksvej 39, 2920, Charlottenlund (Denmark); Jensen, Bente; Noerregaard, Jesper; Danneskiold-Samsoee, Bente; Bliddal, Henning [Parker Institute, Frederiksberg Hospital, Nordre Fasanvej 57, 2000, Frederiksberg (Denmark); Egund, Niels [Department of Radiology, Aarhus University Hospital, 8000, Aarhus C (Denmark)

    2004-06-01

    The purpose of this study was to investigate the treatment response in lateral epicondylitis (tennis elbow) by MRI. Magnetic resonance imaging was obtained in 30 patients with clinical symptoms of lateral epicondylitis of the elbow using T1-, T2- and T2-weighted fat-saturated (FS) sequences. The patients were randomised to either i.m. corticosteroid injection (n=16) or immobilisation in a wrist splint (n=14). Magnetic resonance imaging of the elbow was performed on a 1.5-T MR system at baseline and after 6 weeks. The extensor carpi radialis (ECRB) tendon, the radial collateral ligament, lateral humerus epicondyle at tendon insertion site, joint fluid and signal intensity changes within brachio-radialis and anconeus muscles were evaluated on the MR unit's workstation before and after 6 weeks of treatment. The MRI was performed once in 22 healthy controls for comparison and all images evaluated by an investigator blinded to the clinical status of the subjects. The MR images showed thickening with separation of the ECRB tendon from the radial collateral ligament and abnormal signal change in 25 of the 30 patients on the T1-weighted sequences at inclusion. The signal intensity of the ECRB tendon was increased in 24 of the 30 patients with lateral epicondylitis of the elbow on the T2-weighted FS sequences. (orig.)

  2. Monitoring Tumor Response to Carbogen Breathing by Oxygen-Sensitive Magnetic Resonance Parameters to Predict the Outcome of Radiation Therapy: A Preclinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Cao-Pham, Thanh-Trang; Tran, Ly-Binh-An; Colliez, Florence; Joudiou, Nicolas [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium); El Bachiri, Sabrina [Université Catholique de Louvain, IMMAQ Technological Platform, Methodology and Statistical Support, Louvain-la-Neuve (Belgium); Grégoire, Vincent [Université Catholique de Louvain, Institute of Experimental and Clinical Research, Center for Molecular Imaging, Radiotherapy and Oncology, Brussels (Belgium); Levêque, Philippe; Gallez, Bernard [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium); Jordan, Bénédicte F., E-mail: benedicte.jordan@uclouvain.be [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium)

    2016-09-01

    Purpose: In an effort to develop noninvasive in vivo methods for mapping tumor oxygenation, magnetic resonance (MR)-derived parameters are being considered, including global R{sub 1}, water R{sub 1}, lipids R{sub 1}, and R{sub 2}*. R{sub 1} is sensitive to dissolved molecular oxygen, whereas R{sub 2}* is sensitive to blood oxygenation, detecting changes in dHb. This work compares global R{sub 1}, water R{sub 1}, lipids R{sub 1}, and R{sub 2}* with pO{sub 2} assessed by electron paramagnetic resonance (EPR) oximetry, as potential markers of the outcome of radiation therapy (RT). Methods and Materials: R{sub 1}, R{sub 2}*, and EPR were performed on rhabdomyosarcoma and 9L-glioma tumor models, under air and carbogen breathing conditions (95% O{sub 2}, 5% CO{sub 2}). Because the models demonstrated different radiosensitivity properties toward carbogen, a growth delay (GD) assay was performed on the rhabdomyosarcoma model and a tumor control dose 50% (TCD50) was performed on the 9L-glioma model. Results: Magnetic resonance imaging oxygen-sensitive parameters detected the positive changes in oxygenation induced by carbogen within tumors. No consistent correlation was seen throughout the study between MR parameters and pO{sub 2}. Global and lipids R{sub 1} were found to be correlated to pO{sub 2} in the rhabdomyosarcoma model, whereas R{sub 2}* was found to be inversely correlated to pO{sub 2} in the 9L-glioma model (P=.05 and .03). Carbogen increased the TCD50 of 9L-glioma but did not increase the GD of rhabdomyosarcoma. Only R{sub 2}* was predictive (P<.05) for the curability of 9L-glioma at 40 Gy, a dose that showed a difference in response to RT between carbogen and air-breathing groups. {sup 18}F-FAZA positron emission tomography imaging has been shown to be a predictive marker under the same conditions. Conclusion: This work illustrates the sensitivity of oxygen-sensitive R{sub 1} and R{sub 2}* parameters to changes in tumor oxygenation. However, R{sub 1

  3. Monitoring Tumor Response to Carbogen Breathing by Oxygen-Sensitive Magnetic Resonance Parameters to Predict the Outcome of Radiation Therapy: A Preclinical Study

    International Nuclear Information System (INIS)

    Cao-Pham, Thanh-Trang; Tran, Ly-Binh-An; Colliez, Florence; Joudiou, Nicolas; El Bachiri, Sabrina; Grégoire, Vincent; Levêque, Philippe; Gallez, Bernard; Jordan, Bénédicte F.

    2016-01-01

    Purpose: In an effort to develop noninvasive in vivo methods for mapping tumor oxygenation, magnetic resonance (MR)-derived parameters are being considered, including global R_1, water R_1, lipids R_1, and R_2*. R_1 is sensitive to dissolved molecular oxygen, whereas R_2* is sensitive to blood oxygenation, detecting changes in dHb. This work compares global R_1, water R_1, lipids R_1, and R_2* with pO_2 assessed by electron paramagnetic resonance (EPR) oximetry, as potential markers of the outcome of radiation therapy (RT). Methods and Materials: R_1, R_2*, and EPR were performed on rhabdomyosarcoma and 9L-glioma tumor models, under air and carbogen breathing conditions (95% O_2, 5% CO_2). Because the models demonstrated different radiosensitivity properties toward carbogen, a growth delay (GD) assay was performed on the rhabdomyosarcoma model and a tumor control dose 50% (TCD50) was performed on the 9L-glioma model. Results: Magnetic resonance imaging oxygen-sensitive parameters detected the positive changes in oxygenation induced by carbogen within tumors. No consistent correlation was seen throughout the study between MR parameters and pO_2. Global and lipids R_1 were found to be correlated to pO_2 in the rhabdomyosarcoma model, whereas R_2* was found to be inversely correlated to pO_2 in the 9L-glioma model (P=.05 and .03). Carbogen increased the TCD50 of 9L-glioma but did not increase the GD of rhabdomyosarcoma. Only R_2* was predictive (P<.05) for the curability of 9L-glioma at 40 Gy, a dose that showed a difference in response to RT between carbogen and air-breathing groups. "1"8F-FAZA positron emission tomography imaging has been shown to be a predictive marker under the same conditions. Conclusion: This work illustrates the sensitivity of oxygen-sensitive R_1 and R_2* parameters to changes in tumor oxygenation. However, R_1 parameters showed limitations in terms of predicting the outcome of RT in the tumor models studied, whereas R_2* was found to be

  4. [Comparison of cepstral coefficients to other voice evaluation parameters in patients with occupational dysphonia].

    Science.gov (United States)

    Niebudek-Bogusz, Ewa; Strumiłło, Paweł; Wiktorowicz, Justyna; Sliwińska-Kowalska, Mariola

    2013-01-01

    BACKGROUND Special consideration has recently been given to cepstral analysis with mel-frequency cepstral coefficients (MFCCs). The aim of this study was to assess the applicability of MFCCs in acoustic analysis for diagnosing occupational dysphonia in comparison to subjective and objective parameters of voice evaluation. The study comprised 2 groups, one of 55 female teachers (mean age: 45 years) with occupational dysphonia confirmed by videostroboscopy and 40 female controls with normal voice (mean age: 43 years). The acoustic samples involving sustained vowels "a" and four standardized sentences were analyzed by computed analysis of MFCCs. The results were compared to acoustic parameters of jitter and shimmer groups, noise to harmonic ratio, Yanagihara index evaluating the grade of hoarseness, the aerodynamic parameter: maximum phonation time and also subjective parameters: GRBAS perceptual scale and Voice Handicap Index (VHI). The compared results revealed differences between the study and control groups, significant for MFCC2, MFCC3, MFCC5, MFCC6, MFCC8, MFCC10, particularly for MFCC6 (p teachers correlated with all eight objective parameters, also showed the significant relation with perceptual voice feature A (asthenity) of subjective scale GRBAS, characteristic of weak tired voice. The cepstral analysis with mel frequency cepstral coefficients is a promising tool for evaluating occupational voice disorders, capable of reflecting the perceptual voice features better than other methods of acoustic analysis.

  5. Evaluation of water balance parameters from isotopic measurements in evaporation pans

    International Nuclear Information System (INIS)

    Allison, G.B.

    1979-01-01

    The evaluation of the parameters governing the isotopic composition of evaporating water bodies was attempted by means of evaporation pans. The instability of the meteorological conditions, however, makes it virtually impossible to evaluate the atmospheric relative humidity and its isotopic composition with pans. Pans are only suitable to obtain seasonal trends of the isotopic composition of the net evaporated water. For this, a technique based on two pans is also proposed. (author)

  6. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    International Nuclear Information System (INIS)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc; Schlattmann, Peter

    2017-01-01

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I"2 statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  7. Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Futami, Kazuya; Nambu, Iku; Kitabayashi, Tomohiro; Sano, Hiroki; Misaki, Kouichi; Uchiyama, Naoyuki; Nakada, Mitsutoshi

    2017-01-01

    Prediction of the rupture risk is critical for the identification of unruptured cerebral aneurysms (UCAs) eligible for invasive treatments. The size ratio (SR) is a strong morphological predictor for rupture. We investigated the relationship between the inflow hemodynamics evaluated on four-dimensional (4D) flow magnetic resonance (MR) imaging and the SR to identify specific characteristics related to UCA rupture. We evaluated the inflow jet patterns and inflow hemodynamic parameters of 70 UCAs on 4D flow MR imaging and compared them among 23 aneurysms with an SR ≥2.1 and 47 aneurysms with an SR ≤2.0. Based on the shape of inflow streamline bundles with a velocity ≥75% of the maximum flow velocity in the parent artery, the inflow jet patterns were classified as concentrated (C), diffuse (D), neck-limited (N), and unvisualized (U). The incidence of patterns C and N was significantly higher in aneurysms with an SR ≥2.1. The rate of pattern U was significantly higher in aneurysms with an SR ≤2.0. The maximum inflow rate and the inflow rate ratio were significantly higher in aneurysms with an SR ≥2.1. The SR affected the inflow jet pattern, the maximum inflow rate, and the inflow rate ratio of UCAs. In conjunction with the SR, inflow hemodynamic analysis using 4D flow MR imaging may contribute to the risk stratification for aneurysmal rupture. (orig.)

  8. Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Futami, Kazuya [Matto-Ishikawa Central Hospital, Department of Neurosurgery, Hakusan, Ishikawa (Japan); Nambu, Iku; Kitabayashi, Tomohiro; Sano, Hiroki; Misaki, Kouichi; Uchiyama, Naoyuki; Nakada, Mitsutoshi [Kanazawa University School of Medicine, Department of Neurosurgery, Kanazawa, Ishikawa (Japan)

    2017-04-15

    Prediction of the rupture risk is critical for the identification of unruptured cerebral aneurysms (UCAs) eligible for invasive treatments. The size ratio (SR) is a strong morphological predictor for rupture. We investigated the relationship between the inflow hemodynamics evaluated on four-dimensional (4D) flow magnetic resonance (MR) imaging and the SR to identify specific characteristics related to UCA rupture. We evaluated the inflow jet patterns and inflow hemodynamic parameters of 70 UCAs on 4D flow MR imaging and compared them among 23 aneurysms with an SR ≥2.1 and 47 aneurysms with an SR ≤2.0. Based on the shape of inflow streamline bundles with a velocity ≥75% of the maximum flow velocity in the parent artery, the inflow jet patterns were classified as concentrated (C), diffuse (D), neck-limited (N), and unvisualized (U). The incidence of patterns C and N was significantly higher in aneurysms with an SR ≥2.1. The rate of pattern U was significantly higher in aneurysms with an SR ≤2.0. The maximum inflow rate and the inflow rate ratio were significantly higher in aneurysms with an SR ≥2.1. The SR affected the inflow jet pattern, the maximum inflow rate, and the inflow rate ratio of UCAs. In conjunction with the SR, inflow hemodynamic analysis using 4D flow MR imaging may contribute to the risk stratification for aneurysmal rupture. (orig.)

  9. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schlattmann, Peter [Jena University Hospital, Department of Medical Statistics, Informatics and Documentation, Jena (Germany)

    2017-04-15

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I{sup 2} statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  10. Considerations about the correct evaluation of sorption thermodynamic parameters from equilibrium isotherms

    International Nuclear Information System (INIS)

    Salvestrini, Stefano; Leone, Vincenzo; Iovino, Pasquale; Canzano, Silvana; Capasso, Sante

    2014-01-01

    Highlights: • Different methods to derive sorption thermodynamic parameters have been discussed. • ΔG° and, ΔS° values depend on the selected standard states. • Isosteric heat values help in evaluating the applicability of the sorption models. -- Abstract: This is a comparative analysis of popular methods currently in use to derive sorption thermodynamic parameters from temperature dependence of sorption isotherms. It is emphasized that the standard and isosteric thermodynamic parameters have sharply different meanings. Moreover, it is shown with examples how the sorption model adopted conditions the standard state and consequently the value of ΔG° and ΔS°. These trivial but often neglected aspects should carefully be considered when comparing thermodynamic parameters from different literature sources. An effort by the scientific community is needed to define criteria for the choice of the standard state in sorption processes

  11. The fluorescence intensities ratio is not a reliable parameter for evaluation of protein unfolding transitions.

    Science.gov (United States)

    Žoldák, Gabriel; Jancura, Daniel; Sedlák, Erik

    2017-06-01

    Monitoring the fluorescence of proteins, particularly the fluorescence of intrinsic tryptophan residues, is a popular method often used in the analysis of unfolding transitions (induced by temperature, chemical denaturant, and pH) in proteins. The tryptophan fluorescence provides several suitable parameters, such as steady-state fluorescence intensity, apparent quantum yield, mean fluorescence lifetime, position of emission maximum that are often utilized for the observation of the conformational/unfolding transitions of proteins. In addition, the fluorescence intensities ratio at different wavelengths (usually at 330 nm and 350 nm) is becoming an increasingly popular parameter for the evaluation of thermal transitions. We show that, under certain conditions, the use of this parameter for the analysis of unfolding transitions leads to the incorrect determination of thermodynamic parameters characterizing unfolding transitions in proteins (e.g., melting temperature) and, hence, can compromise the hit identification during high-throughput drug screening campaigns. © 2017 The Protein Society.

  12. Uses of Magnetic Resonance in Post-Surgical Evaluation of Patients with Tetralogy of Fallot

    International Nuclear Information System (INIS)

    Abad, Pedro; Delgado Jorge Andres; Llano Serna, Juan Fernando

    2008-01-01

    The number of patients with tetralogy of Fallot who survive complete reparative surgery is increasing. For this reason the late complications of this procedure, such as pulmonary regurgitation, right ventricular dysfunction, arrhythmias, pulmonary artery stenosis or pseudo aneurysms outflow tract, are becoming more common in clinical practice. Magnetic resonance imaging is the method of choice for the global evaluation of these patients because the ability to evaluate the morphology, quantifying right ventricular function and characterization of the anatomy and function of the pulmonary valve. The knowledge of the embriopathology and the anatomy of this congenital heart disease, and the different interventions, palliative or corrective and the complications are essential for the proper interpretation of the images and making therapeutic decisions.

  13. Quantitative evaluations of left ventricular function obtained by electrocardiographically-gated magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takeda, Tohru; Iida, Kaname; Sugishita, Yasuro; Anno, Izumi; Akisada, Masayoshi; Matsuda, Mitsuo; Akatsuka, Takao; Koseki, Susumu.

    1989-01-01

    Using electrocardiographically-gated magnetic resonance imaging, regional cardiac function was evaluated in 12 normal volunteers and in 10 cases of old myocardial infarction. The optimal short axis of the left ventricle was selected at the chordae tendineae level. The left ventricle was divided into 12 segments using a computer-aided system, and percentile shortening fraction (%SF) and percentile wall thickening (%WT) were calculated in each segment by the fixed coordinate method. In the normal volunteers, heterogeneity of both %FS and %WT was observed, ranging from 25±13% and 37±13%, respectively in the septal segment, to 49±13% and 60±21%, respectively in the posterior segment. In the cases of myocardial infarction, decreased %FS and %WT were detected at the affected regions. The abnormal regions revealed by %WT tended to be narrower than those revealed by %FS. Thus the MR technique at the optimal axis may be useful for quantitative evaluations of regional cardiac function. (author)

  14. Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction

    DEFF Research Database (Denmark)

    Knudsen, H B; Gelineck, J; Søjbjerg, Jens Ole

    1999-01-01

    The aim of this study was to investigate tendon integrity after surgical repair of single-tendon rotator cuff lesions. In 31 patients, 31 single-tendon repairs were evaluated. Thirty-one patients were available for clinical assessment and magnetic resonance imaging (MRI) at follow-up. A standard...... series of MR images was obtained for each. The results of functional assessment were scored according to the system of Constant. According to MRI evaluation, 21 (68%) patients had an intact or thinned rotator cuff and 10 (32%) had recurrence of a full-thickness cuff defect at follow-up. Patients...... with an intact or thinned rotator cuff had a median Constant score of 75.5 points; patients with a full-thickness cuff defect had a median score of 62 points. There was no correlation between tendon integrity on postoperative MR images and functional outcome. Patients with intact or thinned cuffs did not have...

  15. Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Henriksen, O

    1987-01-01

    Several circumstances may explain the great variation in reported proton T1 and T2 relaxation times usually seen. This study was designed to evaluate the accuracy of relaxation time measurements by magnetic resonance imaging (MRI) operating at 1.5 tesla. Using a phantom of nine boxes with different...... concentrations of CuSO4 and correlating the calculated T1 and T2 values with reference values obtained by two spectrometers (corrected to MRI-proton frequency = 64 MHz) we found a maximum deviation of about 10 per cent. Measurements performed on a large water phantom in order to evaluate the homogeneity...... in the imaging plane showed a variation of less than 10 per cent within 10 cm from the centre of the magnet in all three imaging planes. Changing the gradient field strength apparently had no influence on the T2 values recorded. Consequently diffusion processes seem without significance. It is concluded...

  16. Morphological evaluation of complex congenital heart disease by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takahashi, Osahiro

    1993-01-01

    Ninety infants and children with complex congenital heart disease were examined with magnetic resonance imaging and the accuracy of morphological diagnoses by MRI was tested by comparison to the final diagnoses primarily based on angiocardiography. The sensitivity and specificity of MRI diagnoses were generally excellent in evaluating vena caval and atrial morphology, type of AV connection, ventricular morphology, type of VA connection and great vessel morphology. Although some difficulty with evaluating the detailed anatomy of the AV valve and its suspension system and fine vascular structures, MRI could demonstrate the entire cardiac structures clearly and provide the 3-dimensional information regarding the intracardiac structures, and it was extremely valuable in morphological assessment of complex congenital heart disease. (author)

  17. The Hypertrophic Marchigiana: physical and biochemical parameters for meat quality evaluation

    Directory of Open Access Journals (Sweden)

    F. M. Sarti

    2010-04-01

    Full Text Available The aim of this study was to evaluate the meat quality of double muscled Marchigiana young bulls characterized by different genotypes for the hypertrophy: normal and mutated (heterozygous. Calpain and calpastatin activities were determined to verify the state of aging meat on a sample of Longissimus thoracis muscle (XIII thoracic rib taken at slaughtering (0h and after 24 hours (24h. After 14 days of aging, another sample of muscle was taken to evaluate physical and chemical parameters of meat quality. The results showed a better meat quality of mutated animals respect normal animals. Another interesting result was the correlation between the biochemical parameters and some physical parameters, such as WBS (Warner Bratzler Shear Force, CL (Cooking loss. These results showed the relationship between the proteolytic activity of calpain system and meat tenderness.

  18. Mathematical modeling and evaluation of radionuclide transport parameters from the ANL Laboratory Analog Program

    International Nuclear Information System (INIS)

    Chen, B.C.J.; Hull, J.R.; Seitz, M.G.; Sha, W.T.; Shah, V.L.; Soo, S.L.

    1984-07-01

    Computer model simulation is required to evaluate the performance of proposed or future high-level radioactive waste geological repositories. However, the accuracy of a model in predicting the real situation depends on how well the values of the transport properties are prescribed as input parameters. Knowledge of transport parameters is therefore essential. We have modeled ANL's Experiment Analog Program which was designed to simulate long-term radwaste migration process by groundwater flowing through a high-level radioactive waste repository. Using this model and experimental measurements, we have evaluated neptunium (actinide) deposition velocity and analyzed the complex phenomena of simultaneous deposition, erosion, and reentrainment of bentonite when groundwater is flowing through a narrow crack in a basalt rock. The present modeling demonstrates that we can obtain the values of transport parameters, as added information without any additional cost, from the available measurements of laboratory analog experiments. 8 figures, 3 tables

  19. Inverse modeling approach for evaluation of kinetic parameters of a biofilm reactor using tabu search.

    Science.gov (United States)

    Kumar, B Shiva; Venkateswarlu, Ch

    2014-08-01

    The complex nature of biological reactions in biofilm reactors often poses difficulties in analyzing such reactors experimentally. Mathematical models could be very useful for their design and analysis. However, application of biofilm reactor models to practical problems proves somewhat ineffective due to the lack of knowledge of accurate kinetic models and uncertainty in model parameters. In this work, we propose an inverse modeling approach based on tabu search (TS) to estimate the parameters of kinetic and film thickness models. TS is used to estimate these parameters as a consequence of the validation of the mathematical models of the process with the aid of measured data obtained from an experimental fixed-bed anaerobic biofilm reactor involving the treatment of pharmaceutical industry wastewater. The results evaluated for different modeling configurations of varying degrees of complexity illustrate the effectiveness of TS for accurate estimation of kinetic and film thickness model parameters of the biofilm process. The results show that the two-dimensional mathematical model with Edward kinetics (with its optimum parameters as mu(max)rho(s)/Y = 24.57, Ks = 1.352 and Ki = 102.36) and three-parameter film thickness expression (with its estimated parameters as a = 0.289 x 10(-5), b = 1.55 x 10(-4) and c = 15.2 x 10(-6)) better describes the biofilm reactor treating the industry wastewater.

  20. Nonlinear regression analysis for evaluating tracer binding parameters using the programmable K1003 desk computer

    International Nuclear Information System (INIS)

    Sarrach, D.; Strohner, P.

    1986-01-01

    The Gauss-Newton algorithm has been used to evaluate tracer binding parameters of RIA by nonlinear regression analysis. The calculations were carried out on the K1003 desk computer. Equations for simple binding models and its derivatives are presented. The advantages of nonlinear regression analysis over linear regression are demonstrated

  1. Comparison of nuisance parameters in pediatric versus adult randomized trials: a meta-epidemiologic empirical evaluation

    NARCIS (Netherlands)

    Vandermeer, Ben; van der Tweel, Ingeborg; Jansen-van der Weide, Marijke C.; Weinreich, Stephanie S.; Contopoulos-Ioannidis, Despina G.; Bassler, Dirk; Fernandes, Ricardo M.; Askie, Lisa; Saloojee, Haroon; Baiardi, Paola; Ellenberg, Susan S.; van der Lee, Johanna H.

    2018-01-01

    Background: We wished to compare the nuisance parameters of pediatric vs. adult randomized-trials (RCTs) and determine if the latter can be used in sample size computations of the former. Methods: In this meta-epidemiologic empirical evaluation we examined meta-analyses from the Cochrane Database of

  2. Evaluation of selected postural parameters in children who practice kyokushin karate

    Directory of Open Access Journals (Sweden)

    Drzał-Grabiec Justyna

    2014-10-01

    Full Text Available Study aim: martial arts can be traced back thousands of years. Karate is one of the most common martial arts, and both children and adults practice it. The aim of the study was to evaluate selected body posture parameters in children aged 7–10 years who regularly practice karate.

  3. Use of energy analysis to evaluate the parameters of wave fields

    Energy Technology Data Exchange (ETDEWEB)

    Soldatov, V.N.; Sinitsyn, Ye.S.

    1984-01-01

    Algorithms are proposed and studied for energy analysis of the wave fields. A comparative evaluation is made of the resolution of the energy analysis methods. A method is examined for automated processing of the energograms allowing a search for an estimate of the parameters with significant acceleration of the computer calculations and saving of its working storage by designing multipurpose algorithms of data processing.

  4. Correlation of III/V semiconductor etch results with physical parameters of high-density reactive plasmas excited by electron cyclotron resonance

    Science.gov (United States)

    Gerhard, FRANZ; Ralf, MEYER; Markus-Christian, AMANN

    2017-12-01

    Reactive ion etching is the interaction of reactive plasmas with surfaces. To obtain a detailed understanding of this process, significant properties of reactive composite low-pressure plasmas driven by electron cyclotron resonance (ECR) were investigated and compared with the radial uniformity of the etch rate. The determination of the electronic properties of chlorine- and hydrogen-containing plasmas enabled the understanding of the pressure-dependent behavior of the plasma density and provided better insights into the electronic parameters of reactive etch gases. From the electrical evaluation of I(V) characteristics obtained using a Langmuir probe, plasmas of different compositions were investigated. The standard method of Druyvesteyn to derive the electron energy distribution functions by the second derivative of the I(V) characteristics was replaced by a mathematical model which has been evolved to be more robust against noise, mainly, because the first derivative of the I(V) characteristics is used. Special attention was given to the power of the energy dependence in the exponent. In particular, for plasmas that are generated by ECR with EM modes, the existence of Maxwellian distribution functions is not to be taken as a self-evident fact, but the bi-Maxwellian distribution was proven for Ar- and Kr-stabilized plasmas. In addition to the electron temperature, the global uniform discharge model has been shown to be useful for calculating the neutral gas temperature. To what extent the invasive method of using a Langmuir probe could be replaced with the non-invasive optical method of emission spectroscopy, particularly actinometry, was investigated, and the resulting data exhibited the same relative behavior as the Langmuir data. The correlation with etchrate data reveals the large chemical part of the removal process—most striking when the data is compared with etching in pure argon. Although the relative amount of the radial variation of plasma density and

  5. Exertional muscle pain in familial Mediterranean fever patients evaluated by MRI and 31P magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Kushnir, T.; Eshed, I.; Heled, Y.; Livneh, A.; Langevitz, P.; Ben Zvi, I.; Konen, E.; Lidar, M.

    2013-01-01

    Aim: To evaluate the effect of physical activity on the structural, morphological, and metabolic characteristics of the gastrocnemius muscle in familial Mediterranean fever (FMF) patients, utilizing quantitative 31 P magnetic resonance spectroscopy (MRS), in order to elucidate the mechanism of their exertional leg pain. Materials and methods: Eleven FMF patients suffering from exertional leg pain (eight male, three female; mean age 33 years) and six healthy individuals (three male, three female; mean age 39 years) constituted the control group. All of the participants underwent magnetic resonance imaging (MRI) and non-selective 31 P MRS (3 T) of the leg muscles before and after graded exercise on a treadmill. Phosphocreatine (PCr):inorganic phosphate (Pi), PCr:adenosine triphosphate (ATP) ratios and the intracellular pH of the leg muscles were measured using 31 P MRS. Results: For both groups, normal muscle mass with no signal alterations was observed on the MRI images after exercise. The normal range of pre- and post- exercise MRS muscle parameters was observed in both groups. However, the intracellular pH post-exercise, was significantly higher (less acidic) in the FMF group compared to the control group [pH (FMF) = 7.03 ± 0.02; pH (control) 7.00 ± 0.02; p < 0.0006]. Conclusions: The finding of a less prominent, post-exercise acidification of the gastrocnemius muscle in this FMF patient group suggests a forme fruste of glycogenosis. This preliminary observation should be further investigated in a future, larger-scale study

  6. Evaluating of Tear Meniscus Parameters with Optical Coherent Tomography in Dry-Eye Patients

    Directory of Open Access Journals (Sweden)

    Gülizar Soyugelen Demirok

    2013-08-01

    Full Text Available Purpose: To evaluate the changes in meniscus parameters with optical coherence tomography (OCT after treatment and consider the correlation between the OCT parameters and dry-eye tests. Material and Method: Thirty-two dry-eye patients and 30 healthy individuals were included. Visual acuities, biomicroscopic evaluation, Schirmer-I test, tear-break-up time (T-BUT, and lower-tear meniscus parameters measured with OCT were evaluated. Ocular surface disease index (OSDI was performed. The measurements were repeated on the 10th day and 1st month of the treatment. Lower tear meniscus height (LTMH, depth (LTMD, area (LTMA and α-angle were measured. The tear meniscus parameters of the dry-eye group were compared with the control group before treatment, and the correlation between the dry-eye tests and OCT measurements were evaluated. The change in the results of the dry-eye tests and OCT measurements with treatment were assessed. Results: There was statistically no significant difference between the age and gender of the patients in groups. Before treatment the mean Schirmer-I test, TBUT and OSDI scores were different. The LTMH and LTMA were higher in the control group. In the dry-eye group before treatment, there was a negative correlation between the OSDI score and OCT parameters, however, no meaningful correlation was observed between any other test and OCT parameters. Although there were no change in LTMD and α-angle with treatment, the 1st month values of LTMH and LTMA were significantly higher from the pre-treatment and 10th day values. Discussion: When diagnosing dry-eye, TBUT and OSDI scores were found to be more effective compared to Schirmer-I test for the diagnosis of dry eye. Although not adequate by itself, tear meniscus parameters measured with OCT, LTMH and LTMA, may be helpful for evaluating the efficacy of treatment, and the correlation of these two parameters with the OSDI score may increase the objectivity while questioning the

  7. Role of the combination of FA and T2* parameters as a new diagnostic method in therapeutic evaluation of parkinson's disease.

    Science.gov (United States)

    Fang, Yuan; Zheng, Tao; Liu, Lanxiang; Gao, Dawei; Shi, Qinglei; Dong, Yanchao; Du, Dan

    2017-11-17

    Simple diffusion delivery (SDD) has attained good effects with only tiny amounts of drugs. Fractional anisotropy (FA) and relaxation time T2* that indicate the integrity of fiber tracts and iron concentration within brain tissue were used to evaluate the therapeutic effect of SDD. To evaluate therapeutic effect of SDD in the Parkinson's disease (PD) rat model with FA and T2* parameters. Prospective case-control animal study. Thirty-two male Sprague Dawley rats (eight normal, eight PD, eight SDD, and eight subcutaneous injection rats). Single-shot spin echo echo-planar imaging and fast low-angle shot T 2 WI sequences at 3.0T. Parameters of FA and T2* on the treated side of the substantia nigra were measured to evaluate the therapeutic effect of SDD in a PD rat model. The effects of time on FA and T2* values were analyzed by repeated measurement tests. A one-way analysis of variance was conducted, followed by individual comparisons of the mean FA and T2* values at different timepoints. The FA values on the treated side of the substantia nigra in the SDD treatment group and subcutaneous injection treatment group were significantly higher at week 1 and lower at week 6 than that of the PD control group (SDD vs. PD, week 1, adjusted P = 0.012; subcutaneous vs. PD, week 1, adjusted P T2* parameter in the SDD treatment group and subcutaneous injection treatment group was significantly higher than that in the PD control group at week 6 (SDD vs. PD, adjusted P = 0.032; subcutaneous vs. PD, adjusted P T2* parameters can potentially serve as a new effective evaluation method of the therapeutic effect of SDD. 1 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2017. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Magnetic resonance imaging in the evaluation of clinical treatment of otospongiosis: a pilot study.

    Science.gov (United States)

    de Oliveira Vicente, Andy; Chandrasekhar, Sujana S; Yamashita, Helio K; Cruz, Oswaldo Laercio M; Barros, Flavia A; Penido, Norma O

    2015-06-01

    To evaluate the applicability of magnetic resonance imaging (MRI) as a method for monitoring the activity of otospongiotic lesions before and after clinical treatment. Prospective, randomized, controlled, double-blind study. One single tertiary care institution in a large, cosmopolitan city. Twenty-six patients (n = 42 ears) with clinical, audiometric, and tomographic diagnosis of otosclerosis were enrolled. If computed tomography (CT) demonstrated active lesions, these patients underwent MRI to detect otospongiotic foci, seen as areas of gadolinium enhancement. Patients were divided into 3 groups and received treatment with placebo, sodium alendronate, or sodium fluoride for 6 months. After this period, clinical and audiometric evaluations and a second MRI were performed. Each MRI was evaluated by both a neuroradiologist and an otolaryngologist in a subjective (visual) and objective (using specific eFilm Workstation software) manner. Otospongiosis was most predominantly identified in the region anterior to the oval window, and this site was reliable for comparing pre- and posttreatment scans. The patients in the alendronate and sodium fluoride groups had MRI findings that suggested a decrease in activity of otospongiotic lesions, more relevant in the alendronate group. These findings were statistically significant for both subjective and objective MRI evaluations. MRI shows higher sensitivity than clinical or audiometric assessment for detecting reduction in activity of otospongiosis. The objective MRI evaluation based on software analysis was the most accurate method of monitoring clinical treatment response in otospongiosis. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  9. Incidence and Evaluation of Incidental Abnormal Bone Marrow Signal on Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Gunjan L. Shah

    2014-01-01

    Full Text Available Purpose. The increased use of magnetic resonance imaging (MRI has resulted in reports of incidental abnormal bone marrow (BM signal. Our goal was to determine the evaluation of an incidental abnormal BM signal on MRI and the prevalence of a subsequent oncologic diagnosis. Methods. We conducted a retrospective cohort study of patients over age 18 undergoing MRI between May 2005 and October 2010 at Tufts Medical Center (TMC with follow-up through November 2013. The electronic medical record was queried to determine imaging site, reason for scan, evaluation following radiology report, and final diagnosis. Results. 49,678 MRIs were done with 110 patients meeting inclusion criteria. Twenty two percent underwent some evaluation, most commonly a complete blood count, serum protein electrophoresis, or bone scan. With median follow-up of 41 months, 6% of patients were diagnosed with malignancies including multiple myeloma, non-Hodgkins lymphoma, metastatic non-small cell lung cancer, and metastatic adenocarcinoma. One patient who had not undergone evaluation developed breast cancer 24 months after the MRI. Conclusions. Incidentally noted abnormal or heterogeneous bone marrow signal on MRI was not inconsequential and should prompt further evaluation.

  10. Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach

    Directory of Open Access Journals (Sweden)

    Vido Diane

    2008-07-01

    Full Text Available Abstract Background Cardiovascular magnetic resonance (CMR has excellent capabilities to assess ventricular systolic function. Current clinical scenarios warrant routine evaluation of ventricular diastolic function for complete evaluation, especially in congestive heart failure patients. To our knowledge, no systematic assessment of diastolic function over a range of lusitropy has been performed using CMR. Methods and Results Left ventricular diastolic function was assessed in 31 subjects (10 controls who underwent CMR and compared with Transthoracic echocardiogram (TTE evaluation of mitral valve (MV and pulmonary vein (PV blood flow. Blood flow in the MV and PV were successfully imaged by CMR for all cases (31/31,100% while TTE evaluated flow in all MV (31/31,100% but only 21/31 PV (68% cases. Velocities of MV flow (E and A measured by CMR correlated well with TTE (r = 0.81, p Conclusion We have shown that there is homology between CMR and TTE for the assessment of diastolic inflow over a wide range of conditions, including normal, impaired relaxation and restrictive. There is excellent agreement of quantitative velocity measurements between CMR and TTE. Diastolic blood flow assessment by CMR can be performed in a single scan, with times ranging from 20 sec to 3 min, and we show that there is good indication for applying CMR to assess diastolic conditions, either as an adjunctive test when evaluating systolic function, or even as a primary test when TTE data cannot be obtained.

  11. A search for optimal parameters of resonance circuits ensuring damping of electroelastic structure vibrations based on the solution of natural vibration problem

    Science.gov (United States)

    Oshmarin, D.; Sevodina, N.; Iurlov, M.; Iurlova, N.

    2017-06-01

    In this paper, with the aim of providing passive control of structure vibrations a new approach has been proposed for selecting optimal parameters of external electric shunt circuits connected to piezoelectric elements located on the surface of the structure. The approach is based on the mathematical formulation of the natural vibration problem. The results of solution of this problem are the complex eigenfrequencies, the real part of which represents the vibration frequency and the imaginary part corresponds to the damping ratio, characterizing the rate of damping. A criterion of search for optimal parameters of the external passive shunt circuits, which can provide the system with desired dissipative properties, has been derived based on the analysis of responses of the real and imaginary parts of different complex eigenfrequencies to changes in the values of the parameters of the electric circuit. The efficiency of this approach has been verified in the context of natural vibration problem of rigidly clamped plate and semi-cylindrical shell, which is solved for series-connected and parallel -connected external resonance (consisting of resistive and inductive elements) R-L circuits. It has been shown that at lower (more energy-intensive) frequencies, a series-connected external circuit has the advantage of providing lower values of the circuit parameters, which renders it more attractive in terms of practical applications.

  12. Evaluation of selected predictive models and parameters for the environmental transport and dosimetry of radionuclides

    International Nuclear Information System (INIS)

    Miller, C.W.; Dunning, D.E. Jr.; Etnier, E.L.; Hoffman, F.O.; Little, C.A.; Meyer, H.R.; Shaeffer, D.L.; Till, J.E.

    1979-07-01

    Evaluations of selected predictive models and parameters used in the assessment of the environmental transport and dosimetry of radionuclides are summarized. Mator sections of this report include a validation of the Gaussian plume disperson model, comparison of the output of a model for the transport of 131 I from vegetation to milk with field data, validation of a model for the fraction of aerosols intercepted by vegetation, an evaluation of dose conversion factors for 232 Th, an evaluation of considering the effect of age dependency on population dose estimates, and a summary of validation results for hydrologic transport models

  13. Evaluation of Hydraulic Parameters Obtained by Different Measurement Methods for Heterogeneous Gravel Soil

    Directory of Open Access Journals (Sweden)

    Chen Zeng

    2012-01-01

    Full Text Available Knowledge of soil hydraulic parameters for the van Genuchten function is important to characterize soil water movement for watershed management. Accurate and rapid prediction of soil water flow in heterogeneous gravel soil has become a hot topic in recent years. However, it is difficult to precisely estimate hydraulic parameters in a heterogeneous soil with rock fragments. In this study, the HYDRUS-2D numerical model was used to evaluate hydraulic parameters for heterogeneous gravel soil that was irregularly embedded with rock fragments in a grape production base. The centrifugal method (CM, tensiometer method (TM and inverse solution method (ISM were compared for various parameters in the van Genuchten function. The soil core method (SCM, disc infiltration method (DIM and inverse solution method (ISM were also investigated for measuring saturated hydraulic conductivity. Simulation with the DIM approach revealed a problem of overestimating soil water infiltration whereas simulation with the SCM approach revealed a problem of underestimating water movement as compared to actual field observation. The ISM approach produced the best simulation result even though this approach slightly overestimated soil moisture by ignoring the impact of rock fragments. This study provides useful information on the overall evaluation of soil hydraulic parameters attained with different measurement methods for simulating soil water movement and distribution in heterogeneous gravel soil.

  14. Resonant alteration of propagation in guiding structures with complex Robin parameter and its magnetic-field-induced restoration

    International Nuclear Information System (INIS)

    Olendski, O.

    2011-01-01

    Highlights: → Solutions of the wave equation are analyzed for the confined circular geometry with complex Robin boundary conditions. → Sharp extremum is found in the energy dependence on the imaginary part of the extrapolation length. → Nonzero real part of the Robin length or/and magnetic field wipe out the resonance. - Abstract: Solutions of the scalar Helmholtz wave equation are derived for the analysis of the transport and thermodynamic properties of the two-dimensional disk and three-dimensional infinitely long straight wire in the external uniform longitudinal magnetic field B under the assumption that the Robin boundary condition contains extrapolation length Λ with nonzero imaginary part Λ i . As a result of this complexity, the self-adjointness of the Hamiltonian is lost, its eigenvalues E become complex too and the discrete bound states of the disk characteristic for the real Λ turn into the corresponding quasibound states with their lifetime defined by the eigenenergies imaginary parts E i . Accordingly, the longitudinal flux undergoes an alteration as it flows along the wire with its attenuation/amplification being E i -dependent too. It is shown that, for zero magnetic field, the component E i as a function of the Robin imaginary part exhibits a pronounced sharp extremum with its magnitude being the largest for the zero real part Λ r of the extrapolation length. Increasing magnitude of Λ r quenches the E i - Λ i resonance and at very large Λ r the eigenenergies E approach the asymptotic real values independent of Λ i . The extremum is also wiped out by the magnetic field when, for the large B, the energies tend to the Landau levels. Mathematical and physical interpretations of the obtained results are provided; in particular, it is shown that the finite lifetime of the disk quasibound states stems from the Λ i -induced currents flowing through the sample boundary. Possible experimental tests of the calculated effect are discussed; namely

  15. Contactless Abdominal Fat Reduction With Selective RF™ Evaluated by Magnetic Resonance Imaging (MRI): Case Study.

    Science.gov (United States)

    Downie, Jeanine; Kaspar, Miroslav

    2016-04-01

    Noninvasive body shaping methods seem to be an ascending part of the aesthetics market. As a result, the pressure to develop reliable methods for the collection and presentation of their results has also increased. The most used techniques currently include ultrasound measurements of fat thickness in the treated area, caliper measurements, bioimpedance-based scale measurements or circumferential tape measurements. Although these are the most used techniques, almost all of them have some limitations in reproducibility and/or accuracy. This study shows Magnetic Resonance Imaging (MRI) as the new method for the presentation of results in the body shaping industry. Six subjects were treated by a contactless selective radiofrequency device (BTL Vanquish ME, BTL Industries Inc., Boston, MA). The MRI fat thickness was measured at the baseline and at 4-weeks following the treatment. In addition to MRI images and measurements, digital photographs and anthropometric evaluations such as weight, abdominal circumference, and caliper fat thickness measurements were recorded. Abdominal fat thickness measurements from the MRI were performed from the same slices determined by the same tissue artefacts. The MRI fat thickness difference between the baseline measurement and follow up visit showed an average reduction of 5.36 mm as calculated from the data of 5 subjects. One subject dropped out of study due to non-study related issues. The results were statistically significant based on the Student's T-test evaluation. Magnetic resonance imaging abdominal fat thickness measurements seems to be the best method for the evaluation of fat thickness reduction after non-invasive body shaping treatments. In this study, this method shows average fat thickness reduction of 5.36 mm while the weight of the subjects didn't change significantly. A large spot size measuring 1317 cm(2) (204 square inches) covers the abdomen flank to flank. The average thickness of 5.36 mm of the fat layer reduced

  16. Comparison of cepstral coefficients to other voice evaluation parameters in patients with occupational dysphonia

    Directory of Open Access Journals (Sweden)

    Ewa Niebudek-Bogusz

    2013-12-01

    Full Text Available Background: Special consideration has recently been given to cepstral analysis with mel-frequency cepstral coefficients (MFCCs. The aim of this study was to assess the applicability of MFCCs in acoustic analysis for diagnosing occupational dysphonia in comparison to subjective and objective parameters of voice evaluation. Materials and Methods: The study comprised 2 groups, one of 55 female teachers (mean age: 45 years with occupational dysphonia confirmed by videostroboscopy and 40 female controls with normal voice (mean age: 43 years. The acoustic samples involving sustained vowels "a" and four standardized sentences were analyzed by computed analysis of MFCCs. The results were compared to acoustic parameters of jitter and shimmer groups, noise to harmonic ratio, Yanagihara index evaluating the grade of hoarseness, the aerodynamic parameter: maximum phonation time and also subjective parameters: GRBAS perceptual scale and Voice Handicap Index (VHI. Results: The compared results revealed differences between the study and control groups, significant for MFCC2, MFCC3, MFCC5, MFCC6, MFCC8, MFCC10, particularly for MFCC6 (p < 0.001 and MFCC8 (p < 0.009, which may suggest their clinical applicability. In the study group, MFCC4, MFCC8 and MFCC10 correlated significantly with the major objective parameters of voice assessment. Moreover, MFCC8 coefficient, which in the female teachers correlated with all eight objective parameters, also showed the significant relation with perceptual voice feature A (asthenity of subjective scale GRBAS, characteristic of weak tired voice. Conclusions: The cepstral analysis with mel frequency cepstral coefficients is a promising tool for evaluating occupational voice disorders, capable of reflecting the perceptual voice features better than other methods of acoustic analysis. Med Pr 2013;64(6:805–816

  17. Slope stability susceptibility evaluation parameter (SSEP) rating scheme - An approach for landslide hazard zonation

    Science.gov (United States)

    Raghuvanshi, Tarun Kumar; Ibrahim, Jemal; Ayalew, Dereje

    2014-11-01

    In this paper a new slope susceptibility evaluation parameter (SSEP) rating scheme is presented which is developed as an expert evaluation approach for landslide hazard zonation. The SSEP rating scheme is developed by considering intrinsic and external triggering parameters that are responsible for slope instability. The intrinsic parameters which are considered are; slope geometry, slope material (rock or soil type), structural discontinuities, landuse and landcover and groundwater. Besides, external triggering parameters such as, seismicity, rainfall and manmade activities are also considered. For SSEP empirical technique numerical ratings are assigned to each of the intrinsic and triggering parameters on the basis of logical judgments acquired from experience of studies of intrinsic and external triggering factors and their relative impact in inducing instability to the slope. Further, the distribution of maximum SSEP ratings is based on their relative order of importance in contributing instability to the slope. Finally, summation of all ratings for intrinsic and triggering parameter based on actual observation will provide the expected degree of landslide in a given land unit. This information may be utilized to develop a landslide hazard zonation map. The SSEP technique was applied in the area around Wurgessa Kebelle of North Wollo Zonal Administration, Amhara National Regional State in northern Ethiopia, some 490 km from Addis Ababa. The results obtained indicates that 8.33% of the area fall under Moderately hazard and 83.33% fall within High hazard whereas 8.34% of the area fall under Very high hazard. Further, in order to validate the LHZ map prepared during the study, active landslide activities and potential instability areas, delineated through inventory mapping was overlain on it. All active landslide activities and potential instability areas fall within very high and high hazard zone. Thus, the satisfactory agreement confirms the rationality of

  18. The impact of new partial AUC parameters for evaluating the bioequivalence of prolonged-release formulations.

    Science.gov (United States)

    Boily, Michaël; Dussault, Catherine; Massicotte, Julie; Guibord, Pascal; Lefebvre, Marc

    2015-01-23

    To demonstrate bioequivalence (BE) between two prolonged-release (PR) drug formulations, single dose studies under fasting and fed state as well as at least one steady-state study are currently required by the European Medicines Agency (EMA). Recently, however, there have been debates regarding the relevance of steady-state studies. New requirements in single-dose investigations have also been suggested by the EMA to address the absence of a parameter that can adequately assess the equivalence of the shape of the curves. In the draft guideline issued in 2013, new partial area under the curve (pAUC) pharmacokinetic (PK) parameters were introduced to that effect. In light of these potential changes, there is a need of supportive clinical evidence to evaluate the impact of pAUCs on the evaluation of BE between PR formulations. In this retrospective analysis, it was investigated whether the newly defined parameters were associated with an increase in discriminatory ability or a change in variability compared to the conventional PK parameters. Among the single dose studies that met the requirements already in place, 20% were found unable to meet the EMA's new requirements in regards to the pAUC PK parameters. When pairing fasting and fed studies for a same formulation, the failure rate increased to 40%. In some cases, due to the high variability of these parameters, an increase of the sample size would be required to prove BE. In other cases however, the pAUC parameters demonstrated a robust ability to detect differences between the shapes of the curves of PR formulations. The present analysis should help to better understand the impact of the upcoming changes in European regulations on PR formulations and in the design of future BE studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Evaluation of microstructural parameters of oxide dispersion strengthened steels from X-ray diffraction profiles

    International Nuclear Information System (INIS)

    Vlasenko, Svetlana; Benediktovitch, Andrei; Ulyanenkova, Tatjana; Uglov, Vladimir; Skuratov, Vladimir; O'Connell, Jacques; Neethling, Johannes

    2016-01-01

    The microstructural parameters of oxide dispersion strengthened (ODS) steels from measured diffraction profiles were evaluated using an approach where the complex oxide nanoparticles (Y 2 Ti 2 O 7 and Y 4 Al 2 O 9 ) are modeled as spherical inclusions in the steel matrix with coherent or incoherent boundaries. The proposed method enables processing of diffraction data from materials containing spherical inclusions in addition to straight dislocations, and taking into account broadening due to crystallite size and instrumental effects. The parameters of crystallite size distribution modeled by a lognormal distribution function (the parameters m and σ), the strain anisotropy parameter q, the dislocation density ρ, the dislocation arrangement parameter M, the density of oxide nanoparticles ρ np and the nanoparticle radius r 0 were determined for the ODS steel samples. The results obtained are in good agreement with the results of transmission electron microscopy (TEM). - Highlights: • The microstructural parameters of oxide dispersion strengthened steels were obtained. • The microstructure of irradiated and unirradiated samples was investigated. • Oxide nanoparticles are modeled as spherical inclusions. • We considered the influence of dislocations, inclusions and size effects.

  20. Evaluation of microstructural parameters of oxide dispersion strengthened steels from X-ray diffraction profiles

    Energy Technology Data Exchange (ETDEWEB)

    Vlasenko, Svetlana, E-mail: svetlana.vlasenko.bsu@gmail.com [Belarusian State University, Nezavisimosti Avenue 4, Minsk (Belarus); Benediktovitch, Andrei [Belarusian State University, Nezavisimosti Avenue 4, Minsk (Belarus); Ulyanenkova, Tatjana [Rigaku Europe SE, Am Hardtwald 11, Ettlingen (Germany); Uglov, Vladimir [Belarusian State University, Nezavisimosti Avenue 4, Minsk (Belarus); Tomsk Polytechnic University, Lenina Avenue 2a, Tomsk (Russian Federation); Skuratov, Vladimir [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Dubna (Russian Federation); O' Connell, Jacques; Neethling, Johannes [Centre for High Resolution Transmission Electron Microscopy, Nelson Mandela Metropolitan University, Port Elizabeth (South Africa)

    2016-03-15

    The microstructural parameters of oxide dispersion strengthened (ODS) steels from measured diffraction profiles were evaluated using an approach where the complex oxide nanoparticles (Y{sub 2}Ti{sub 2}O{sub 7} and Y{sub 4}Al{sub 2}O{sub 9}) are modeled as spherical inclusions in the steel matrix with coherent or incoherent boundaries. The proposed method enables processing of diffraction data from materials containing spherical inclusions in addition to straight dislocations, and taking into account broadening due to crystallite size and instrumental effects. The parameters of crystallite size distribution modeled by a lognormal distribution function (the parameters m and σ), the strain anisotropy parameter q, the dislocation density ρ, the dislocation arrangement parameter M, the density of oxide nanoparticles ρ{sub np} and the nanoparticle radius r{sub 0} were determined for the ODS steel samples. The results obtained are in good agreement with the results of transmission electron microscopy (TEM). - Highlights: • The microstructural parameters of oxide dispersion strengthened steels were obtained. • The microstructure of irradiated and unirradiated samples was investigated. • Oxide nanoparticles are modeled as spherical inclusions. • We considered the influence of dislocations, inclusions and size effects.

  1. Distribution and absorption of local anesthetics in inferior alveolar nerve block: evaluation by magnetic resonance imaging.

    Science.gov (United States)

    Ay, Sinan; Küçük, Dervisşhan; Gümüş, Cesur; Kara, M Isa

    2011-11-01

    The aim of this study was to evaluate the distribution and absorption of local anesthetic solutions in inferior alveolar nerve block using magnetic resonance imaging. Forty healthy volunteers were divided into 4 groups and injected with 1.5 mL for inferior alveolar nerve block and 0.3 mL for lingual nerve block. The solutions used for the different groups were 2% lidocaine, 2% lidocaine with 0.125 mg/mL epinephrine, 4% articaine with 0.006 mg/mL epinephrine, and 4% articaine with 0.012 mg/mL epinephrine. All subjects had axial T2-weighted and fat-suppressed images at 0, 60, and 120 minutes after injection. The localization, area, and intensity (signal characteristics) of the solutions were analyzed and onset and duration times of the anesthesia were recorded. There were no significant differences between groups with regard to the intensity and area of the solutions at 0, 60, and 120 minutes after injection, but differences were found within each group. No between-group differences were found on magnetic resonance imaging in the distribution and absorption of lidocaine with or without epinephrine and articaine with 0.006 and 0.012 mg/mL epinephrine. All solutions were noticeably absorbed at 120 minutes after injection. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of thermal effects on the beam quality of disk laser with unstable resonator

    Science.gov (United States)

    Shayganmanesh, Mahdi; Beirami, Reza

    2017-01-01

    In this paper thermal effects of the disk active medium and associated effects on the beam quality of laser are investigated. Using Collins integral and iterative method, transverse mode of an unstable resonator including a Yb:YAG active medium in disk geometry is calculated. After that the beam quality of the laser is calculated based on the generalized beam characterization method. Thermal lensing of the disk is calculated based on the OPD (Optical Path Difference) concept. Five factors influencing the OPD including temperature gradient, disk thermal expansion, photo-elastic effect, electronic lens and disk deformation are considered in our calculations. The calculations show that the effect of disk deformation factor on the quality of laser beam in the resonator is strong. However the total effect of all the thermal factors on the internal beam quality is fewer. Also it is shown that thermal effects degrade the output power, beam profile and beam quality of the output laser beam severely. As well the magnitude of each of affecting factors is evaluated distinctly.

  3. Relevance of Postoperative Magnetic Resonance Images in Evaluating Epidural Hematoma After Thoracic Fixation Surgery.

    Science.gov (United States)

    Shin, Hong Kyung; Choi, Il; Roh, Sung Woo; Rhim, Seung Chul; Jeon, Sang Ryong

    2017-11-01

    It is difficult to evaluate the significant findings of epidural hematoma in magnetic resonance images (MRIs) obtained immediately after thoracic posterior screw fixation (PSF). Prospectively, immediate postoperative MRI was performed in 10 patients who underwent thoracic PSF from April to December 2013. Additionally, we retrospectively analyzed the MRIs from 3 patients before hematoma evacuation out of 260 patients who underwent thoracic PSF from January 2000 to March 2013. The MRI findings of 9 out of the 10 patients, consecutively collected after thoracic PSF, showed neurologic recovery with a well-preserved cerebrospinal fluid (CSF) space and no prominent hemorrhage. Even though there were metal artifacts at the level of the pedicle screws, the preserved CSF space was observed. In contrast, the MRI of 1 patient with poor neurologic outcome demonstrated a typical hematoma and slight spinal cord compression and reduced CSF space. In the retrospective analysis of the 3 patients who showed definite motor weakness in the lower extremities after their first thoracic fusion surgery and underwent hematoma evacuation, the magnetic resonance images before hematoma evacuation also revealed hematoma compressing the spinal cord and diminished CSF space. This study shows that epidural hematomas can be detected on MRI performed immediately after thoracic fixation surgery, despite metal artifacts and findings such as hematoma causing spinal cord compression. Loss of CSF space should be considered to be associated with neurologic deficit. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Magnetic resonance imaging in the evaluation of osteochondritis dissecans of the patella

    International Nuclear Information System (INIS)

    Choi, Yun Sun; Cohen, Noah A.; Potter, Hollis G.; Mintz, Douglas N.

    2007-01-01

    The objective was to evaluate the magnetic resonance (MR) appearance of patellar osteochondritis dissecans (OCD). We retrospectively analyzed MR images of 16 patients (18 cases, mean age 20 years) using OCD of the patella. In 5 cases surgery was carried out, and we compared the surgical findings with the MR imaging findings in these cases. In all 18 cases, OCD was located central-inferiorly on the patella, and the average size was 11 x 11 x 7 mm. Subchondral deformities were present in 16 out of 18 cases (88.9%), subchondral cyst formation in 4 cases (22.2%), reactive bone marrow signal in 8 cases (44.4%), overlying patellar cartilage abnormality in 14 cases (77.8%), loose body in 2 cases (11.1%), patella alta in 8 cases (44.4%), hypoplastic sulcus in 7 cases (38.9%), and synovitis in 4 cases (22.2%). In all 5 cases in which surgery was carried out, the cartilage abnormality classified on the MR images was confirmed, and a loose body was removed at arthroscopy in 2 of the 5 cases. Magnetic resonance imaging of patellar OCD typically shows subchondral deformity and variable abnormalities of the overlying patellar cartilage located central-inferiorly on the patella. (orig.)

  5. Evaluating the Performance of Polynomial Regression Method with Different Parameters during Color Characterization

    Directory of Open Access Journals (Sweden)

    Bangyong Sun

    2014-01-01

    Full Text Available The polynomial regression method is employed to calculate the relationship of device color space and CIE color space for color characterization, and the performance of different expressions with specific parameters is evaluated. Firstly, the polynomial equation for color conversion is established and the computation of polynomial coefficients is analysed. And then different forms of polynomial equations are used to calculate the RGB and CMYK’s CIE color values, while the corresponding color errors are compared. At last, an optimal polynomial expression is obtained by analysing several related parameters during color conversion, including polynomial numbers, the degree of polynomial terms, the selection of CIE visual spaces, and the linearization.

  6. [Information content of immunologic parameters in the evaluation of the effects of hazardous substances].

    Science.gov (United States)

    Litovskaia, A V; Sadovskiĭ, V V; Vifleemskiĭ, A B

    1995-01-01

    Clinical and immunologic examination including 1 and 2 level tests covered 429 staffers of chemical enterprises and 1122 of those engaged into microbiological synthesis of proteins, both the groups exposed to some irritating gases and isocyanates. Using calculation of Kulbak's criterion, the studies selected informative parameters to diagnose immune disturbances caused by occupational hazards. For integral evaluation of immune state, the authors applied general immunologic parameter, meanings of which can serve as criteria for early diagnosis of various immune disorders and for definition of risk groups among industrial workers exposed to occupational biologic and chemical hazards.

  7. Evaluating the pacemaker effect with the pump parameter of gated blood-pool imaging

    International Nuclear Information System (INIS)

    Cheng Muhua

    1995-01-01

    13 normal controls and 27 patients with ventricular pacemaker had undergone planar gated blood-pool imaging in different conditions. Result shows: (1) Pump parameters can successfully reflect therapeutic effect of pacemaker among them EMP is the most valuable parameter for evaluating the cardiac pumping effect. (2) After implantation of the ventricular pacemaker, the LVEF did not increase, but the CO and EMP was significantly increased. (3) Compared with right ventricular demand pacemaker, the rate-responsive ventricular pacemaker give better hemodynamic benefit at exercise condition. (4) Through restrained cardiac pacemaker the functional change was analyzed on or off pace, and monitoring the cardiac function itself after the pacemaker was implanted

  8. Investigation of some parameters influencing the sensitivity of human tooth enamel to gamma radiation using electron paramagnetic resonance

    International Nuclear Information System (INIS)

    El-Faramawy, N.

    2008-01-01

    Electron paramagnetic resonance (EPR) has been successfully used as a physical technique for gamma radiation dose reconstruction using calcified tissues. To minimize potential discrepancies between EPR readings in future studies, the effects of cavity response factor, tooth position and donor gender on the estimated gamma radiation dose were studied. It was found that the EPR response per sample mass used for assessment of doses in teeth outside of the 70-100 mg range should be corrected by a factor which is a function of the sample mass. In the EPR measurements, the difference in sensitivity of different tooth positions to γ-radiation was taken into consideration. It was determined that among all the premolars and molars tooth positions, the relative standard deviation of sensitivity was 6.5%, with the wisdom teeth and the first molars having the highest and lowest sensitivity to γ-radiation, respectively. The current results reveal no effect of the donor gender on the sensitivity to γ-radiation. (author)

  9. An Integrated Lumped Parameter-CFD approach for off-design ejector performance evaluation

    International Nuclear Information System (INIS)

    Besagni, Giorgio; Mereu, Riccardo; Chiesa, Paolo; Inzoli, Fabio

    2015-01-01

    Highlights: • We validate a CFD approach for a convergent nozzle ejector using global and local measurement. • We evaluate seven RANS turbulence models for convergent nozzle ejector. • We introduce a lumped parameter model for on-design and off-design ejector performance evaluation. • We analyze the relationship between local flow behavior and lumped parameters of the model. • We discuss how to improve predicting capabilities of the model by variable parameters calibrated on CFD simulations. - Abstract: This paper presents an Integrated Lumped Parameter Model-Computational Fluid-Dynamics approach for off-design ejector performance evaluation. The purpose of this approach is to evaluate the entrainment ratio, for a fixed geometry, in both on-design and off-design operating conditions. The proposed model is based on a Lumped Parameter Model (LPM) with variable ejector component efficiencies provided by CFD simulations. The CFD results are used for developing maps for ejector component efficiencies in a broad range of operating conditions. The ejector component efficiency maps couple the CFD and the LPM techniques for building an Integrated LPM-CFD approach. The proposed approach is demonstrated for a convergent nozzle ejector and the paper is structured in four parts. At first, the CFD approach is validated by global and local data and seven Reynolds Averaged Navier Stokes (RANS) turbulence models are compared: the k–ω SST showed good performance and was selected for the rest of the analysis. At second, a Lumped Parameter Model (LPM) for subsonic ejector is developed and the ejector component efficiencies have been defined. At third, the CFD approach is used to investigate the flow field, to analyze its influence on ejector component efficiencies and to propose efficiency correlations and maps linking ejector component efficiencies and local flow quantities. In the last part, the efficiency maps are embedded into the lumped parameter model, thus creating

  10. Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function

    International Nuclear Information System (INIS)

    Wintersperger, Bernd J.; Dietrich, Olaf; Huber, Armin; Reiser, Maximilian F.; Schoenberg, Stefan O.; Sincleair, Spencer; Runge, Val M.

    2007-01-01

    The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach (all r 2 =0.99, P<0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (κ=0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter (∝75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution. (orig.)

  11. Magnetic resonance imaging pre- and postoperative evaluation of tetralogy of Fallot

    International Nuclear Information System (INIS)

    Bernardes, Renata Junqueira Moll; Simoes, Luiz Carlos

    2004-01-01

    The purpose of this study was to assess the usefulness of magnetic resonance imaging (MRI) in the pre- and postoperative evaluation of patients with tetralogy of Fallot. Twenty patients aged 1 to 29 years were prospectively evaluated with black-blood and contrast-enhanced angiographic techniques, 11 with the classic form of tetralogy of Fallot and 9 with tetralogy of Fallot and pulmonary atresia. MRI studies provided adequate visualization of the aorta that was classified as dilated or not dilated, and definition of its position in all cases. The use of contrast-enhanced MR angiographic techniques provided excellent imaging of the main right and left pulmonary arteries. The results suggest that MRI, including contrast-enhanced angiography techniques, is a useful tool in the evaluation of patients with tetralogy of Fallot before and after cardiac surgery since it provides important anatomical information that is not always obtained with echocardiography. MRI can be considered an alternative to cardiac catheterization, particularly in the evaluation of the pulmonary vascular anatomy. (author)

  12. Mean cross sections of fast neutrons radiative capture, transmission and mean resonance parameters for the tin isotopes

    International Nuclear Information System (INIS)

    Timokhov, V.M.; Bokhovko, M.V.; Kazakov, L.E.; Kononov, V.N.; Manturov, G.N.; Poletaev, E.D.

    1988-01-01

    Results of measurements of neutron radiative capture cross sections in the energy range of 20-450 keV and of neutron transmission in the energy range of 20-1400 keV for 112,114,115,116,117,118,119,120,122 ,124S n isotopes and natural mixture of tin are presented. Analysis of the experimental data in the framework of nuclear reactions statistical theory is carried out, as a result of which data on neutron and radiation strength functions, potential scattering radii for S- and P-neutrons, as well as nuclear levels density parameters, are obtained

  13. Magnetic resonance imaging of cleft palate patients after a palatoplasty to evaluate the nasopharyngeal results

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroto [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Kadomatsu, Koichi; Hori, Shigeru; Miyata, Masayuki; Kozono, Kikuo; Onizuka, Takuya

    1995-10-01

    Magnetic resonance imaging (MRI) of 16 cleft palate patients was undertaken after a palatoplasty to evaluate the postoperative status of the nasopharyngeal soft tissue, the soft palate, and a pharyngeal flap. As MRI revealed no abnormal findings in the nasopharyngeal muscle of all 16 patients, we concluded that the palatoplasty had normalized the positioning and volume of the levator veli muscle and the muscle sling of the palate. Further, although most of the pharyngeal flaps had an adequate inner muscle volume, some flaps had shrunk and 1 flap was found to have more mucous tissue than muscle. These pharyngeal flap deficits may have been due to rough flap handling during the surgical intervention. Therefore, gentle manipulation of such flaps during the course of surgery is emphasized. (author).

  14. Magnetic resonance imaging of cleft palate patients after a palatoplasty to evaluate the nasopharyngeal results

    International Nuclear Information System (INIS)

    Ikeda, Hiroto; Kadomatsu, Koichi; Hori, Shigeru; Miyata, Masayuki; Kozono, Kikuo; Onizuka, Takuya.

    1995-01-01

    Magnetic resonance imaging (MRI) of 16 cleft palate patients was undertaken after a palatoplasty to evaluate the postoperative status of the nasopharyngeal soft tissue, the soft palate, and a pharyngeal flap. As MRI revealed no abnormal findings in the nasopharyngeal muscle of all 16 patients, we concluded that the palatoplasty had normalized the positioning and volume of the levator veli muscle and the muscle sling of the palate. Further, although most of the pharyngeal flaps had an adequate inner muscle volume, some flaps had shrunk and 1 flap was found to have more mucous tissue than muscle. These pharyngeal flap deficits may have been due to rough flap handling during the surgical intervention. Therefore, gentle manipulation of such flaps during the course of surgery is emphasized. (author)

  15. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    Energy Technology Data Exchange (ETDEWEB)

    Appenzeller, Simone; Kobayashi, Eliane; Costallat, Lilian T.L.; Zanardi, Veronica de Araujo; Ribeiro Neto, Jose Menezes; Damasceno, Benito Pereira; Cendes, Fernando [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2000-03-01

    To describe the role of magnetic resonance imaging (MRI) in the evaluation of patients with chronic and recurrent aseptic meningitis. Method: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. Results: MRI showed small multifocal lesions hyperintense on T2 weight images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behcet's disease or systemic lupus erythematosus). After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. Conclusion: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients. (author)

  16. Evaluation of potential practical oral contrast agents for pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bisset, G.S. III; Cincinnati Univ., OH; Children's Hospital Medical Center, Cincinnati, OH

    1989-01-01

    Development of a practical oral contrast agent for magnetic resonance imaging is necessary to improve differentiation of bowel from adjacent structures. In order to find a readily available, inexpensive, non-toxic, palatable solution for use in the pediatric population, several formulas, milk products and a common oral sedative were evaluated in vitro. T1, T2 and signal intensity measurements were performed on a 1.5 T system. Similac with standard iron proved to be a useful high signal intensity agent on multiple pulse sequences. Early in vivo experience in four normal volunteers indicates that this agent provides excellent delineation of the stomach and duodenum from contiguous viscera. Distal small bowel visualization is less predictabel. Further clinical trials should confirm the utility of this solution, which contains a combination of iron salts and paramagnetic metallic ions. (orig.)

  17. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    International Nuclear Information System (INIS)

    Appenzeller, Simone; Kobayashi, Eliane; Costallat, Lilian T.L.; Zanardi, Veronica de Araujo; Ribeiro Neto, Jose Menezes; Damasceno, Benito Pereira; Cendes, Fernando

    2000-01-01

    To describe the role of magnetic resonance imaging (MRI) in the evaluation of patients with chronic and recurrent aseptic meningitis. Method: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. Results: MRI showed small multifocal lesions hyperintense on T2 weight images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behcet's disease or systemic lupus erythematosus). After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. Conclusion: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients. (author)

  18. Evaluation of the fetal abdomen by magnetic resonance imaging. Part 2: abdominal wall defects and tumors

    Directory of Open Access Journals (Sweden)

    Ana Paula Pinho Matos

    2018-05-01

    Full Text Available Abstract Although ultrasound is still the gold standard for the assessment of fetal malformations, magnetic resonance imaging (MRI has gained great prominence in recent years. In situations in which ultrasound has low sensitivity, such as maternal obesity, abdominal scarring, and oligohydramnios, MRI has proven to be a safe and accurate method. Regarding fetal abdominal wall defects, MRI appears to be widely used in the prognostic assessment of gastroschisis with intestinal atresia or of complications of omphalocele, allowing better perinatal management and parental counseling. In addition, MRI allows the assessment of local invasion of fetal abdominal tumors, with significant prognostic value for the postnatal period. In this article, we review the main MRI findings in the evaluation of fetal abdominal wall defects and tumors.

  19. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  20. Evaluation of biexponential relaxation behaviour in the human brain by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Henriksen, O

    1989-01-01

    Quantitative estimation of individual biologic components in relaxation curves obtained in vivo may increase the specificity of tissue characterization by magnetic resonance imaging. In this study, the potential of biexponential curve analysis was evaluated in T1 and T2 measurements on the human...... brain at 1.5 tesla. Optimal experimental conditions were carefully observed, including the use of long TR values and a very small voxel size. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination involved a multiple spin echo sequence with 32...... echoes. No genuine biexponentiality was demonstrated in the T1 and T2 relaxation processes of white matter, cortical grey matter, or cerebrospinal fluid. Thus, a monoexponential model seems adequate for description of the relaxation behaviour in these cases. Furthermore, the results suggest...

  1. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  2. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    Directory of Open Access Journals (Sweden)

    APPENZELLER SIMONE

    2000-01-01

    Full Text Available OBJECTIVE: To describe the role of magnetic resonance imaging (MRI in the evaluation of patients with chronic and recurrent aseptic meningitis.METHOD: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. RESULTS: MRI showed small multifocal lesions hyperintense on T2 weighted images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behçet´s disease or systemic lupus erythematosus. After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. CONCLUSION: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients.

  3. Evaluation of intense rainfall parameters interpolation methods for the Espírito Santo State

    Directory of Open Access Journals (Sweden)

    José Eduardo Macedo Pezzopane

    2009-12-01

    Full Text Available Intense rainfalls are often responsible for the occurrence of undesirable processes in agricultural and forest areas, such as surface runoff, soil erosion and flooding. The knowledge of intense rainfall spatial distribution is important to agricultural watershed management, soil conservation and to the design of hydraulic structures. The present paper evaluated methods of spatial interpolation of the intense rainfall parameters (“K”, “a”, “b” and “c” for the Espírito Santo State, Brazil. Were compared real intense rainfall rates with those calculated by the interpolated intense rainfall parameters, considering different durations and return periods. Inverse distance to the 5th power IPD5 was the spatial interpolation method with better performance to spatial interpolated intense rainfall parameters.

  4. Quantitative evaluation methods of skin condition based on texture feature parameters

    Directory of Open Access Journals (Sweden)

    Hui Pang

    2017-03-01

    Full Text Available In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  5. Quantitative evaluation methods of skin condition based on texture feature parameters.

    Science.gov (United States)

    Pang, Hui; Chen, Tianhua; Wang, Xiaoyi; Chang, Zhineng; Shao, Siqi; Zhao, Jing

    2017-03-01

    In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM) is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  6. Evaluation for Bearing Wear States Based on Online Oil Multi-Parameters Monitoring

    Directory of Open Access Journals (Sweden)

    Si-Yuan Wang

    2018-04-01

    Full Text Available As bearings are critical components of a mechanical system, it is important to characterize their wear states and evaluate health conditions. In this paper, a novel approach for analyzing the relationship between online oil multi-parameter monitoring samples and bearing wear states has been proposed based on an improved gray k-means clustering model (G-KCM. First, an online monitoring system with multiple sensors for bearings is established, obtaining oil multi-parameter data and vibration signals for bearings through the whole lifetime. Secondly, a gray correlation degree distance matrix is generated using a gray correlation model (GCM to express the relationship of oil monitoring samples at different times and then a KCM is applied to cluster the matrix. Analysis and experimental results show that there is an obvious correspondence that state changing coincides basically in time between the lubricants’ multi-parameters and the bearings’ wear states. It also has shown that online oil samples with multi-parameters have early wear failure prediction ability for bearings superior to vibration signals. It is expected to realize online oil monitoring and evaluation for bearing health condition and to provide a novel approach for early identification of bearing-related failure modes.

  7. Evaluation for Bearing Wear States Based on Online Oil Multi-Parameters Monitoring

    Science.gov (United States)

    Hu, Hai-Feng

    2018-01-01

    As bearings are critical components of a mechanical system, it is important to characterize their wear states and evaluate health conditions. In this paper, a novel approach for analyzing the relationship between online oil multi-parameter monitoring samples and bearing wear states has been proposed based on an improved gray k-means clustering model (G-KCM). First, an online monitoring system with multiple sensors for bearings is established, obtaining oil multi-parameter data and vibration signals for bearings through the whole lifetime. Secondly, a gray correlation degree distance matrix is generated using a gray correlation model (GCM) to express the relationship of oil monitoring samples at different times and then a KCM is applied to cluster the matrix. Analysis and experimental results show that there is an obvious correspondence that state changing coincides basically in time between the lubricants’ multi-parameters and the bearings’ wear states. It also has shown that online oil samples with multi-parameters have early wear failure prediction ability for bearings superior to vibration signals. It is expected to realize online oil monitoring and evaluation for bearing health condition and to provide a novel approach for early identification of bearing-related failure modes. PMID:29621175

  8. Inter relationship between some routine semen evaluation parameters in Jersey X local hill cattle crossbred bulls

    Directory of Open Access Journals (Sweden)

    S. Kapoor

    2012-05-01

    Full Text Available The present study was conducted with an objective of establishing a relationship between various routine semen evaluation parameters. Work was conducted at Sperm Station Palampur, Himachal Pradesh, on the semen from five Jersey X local hill cattle crossbred breeding bulls. A total of 40 ejaculates (8 from each bull, were analysed at five different stages of processing namely post dilution, post equilibration, post thaw and after 1 and 2 hours incubation post thaw at 37°C for progressive motility, live dead count, reaction to hypo-osmotic solution, acrosomal integrity and gross morphological abnormalities. The results of the study revealed a highly significant (P<0.01 correlation between the various semen evaluation parameters except for the gross morphological abnormalities where there was a significant (P<0.05 negative correlation between the acrosomal integrity and gross morphological abnormalities.

  9. Interpretation of hydraulic conductivity data and parameter evaluation for groundwater flow models

    International Nuclear Information System (INIS)

    Niemi, A.

    1991-01-01

    The report reviews recent developments in evaluating effective permeabilities for groundwater flow models, starting from methods of well test interpretation for and proceeding to the principles of parameter estimation. Basic concepts of parameter evaluation as well as expressions derived for effective permeabilities in traditional porous medium are described. Due to the assumptions made, these do often not apply for fractured media. Specific features of fractured medium are discussed, including approaches used determining the size of a possible REV and questions related to the application of stochastic theories. Due to the difficulties encountered when applying traditional deterministic models for fractured media, stochastic and fracture network approaches have been developed. The application of these techniques is still under development, the main questions to be resolved being related to the scarcity of data

  10. Evaluation of cyclone geometry and its influence on performance parameters by computational fluid dynamics (CFD

    Directory of Open Access Journals (Sweden)

    W. P. Martignoni

    2007-03-01

    Full Text Available Cyclone models have been used without relevant modifications for more than a century. Most of the attention has been focused on finding new methods to improve performance parameters. Recently, some studies were conducted to improve equipment performance by evaluating geometric effects on projects. In this work, the effect of cyclone geometry was studied through the creation of a symmetrical inlet and a volute scroll outlet section in an experimental cyclone and comparison to an ordinary single tangential inlet. The study was performed for gas-solid flow, based on an experimental study available in the literature, where a conventional cyclone model was used. Numerical experiments were performed by using CFX 5.7.1. The axial and tangential velocity components were evaluated using RSM and LES turbulence models. Results showed that these new designs can improve the cyclone performance parameters significantly and very interesting details were found on cyclone fluid dynamics properties using RSM and LES.

  11. Evaluation of unconfined-aquifer parameters from pumping test data by nonlinear least squares

    Science.gov (United States)

    Heidari, Manoutchehr; Wench, Allen

    1997-05-01

    Nonlinear least squares (NLS) with automatic differentiation was used to estimate aquifer parameters from drawdown data obtained from published pumping tests conducted in homogeneous, water-table aquifers. The method is based on a technique that seeks to minimize the squares of residuals between observed and calculated drawdown subject to bounds that are placed on the parameter of interest. The analytical model developed by Neuman for flow to a partially penetrating well of infinitesimal diameter situated in an infinite, homogeneous and anisotropic aquifer was used to obtain calculated drawdown. NLS was first applied to synthetic drawdown data from a hypothetical but realistic aquifer to demonstrate that the relevant hydraulic parameters (storativity, specific yield, and horizontal and vertical hydraulic conductivity) can be evaluated accurately. Next the method was used to estimate the parameters at three field sites with widely varying hydraulic properties. NLS produced unbiased estimates of the aquifer parameters that are close to the estimates obtained with the same data using a visual curve-matching approach. Small differences in the estimates are a consequence of subjective interpretation introduced in the visual approach.

  12. The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review

    International Nuclear Information System (INIS)

    Rodriguez-Martin, Juan; Pretell-Mazzini, Juan

    2011-01-01

    The interosseous membrane of the forearm is an important structure to consider in cases of elbow and forearm trauma; it can be injured after elbow or forearm fractures, leading to longitudinal forearm instability. Diagnosis of interosseous membrane injuries is challenging, and failure in diagnosis may result in poor clinical outcomes and complications. Magnetic resonance imaging and ultrasound have shown to be valuable methods for the evaluation of this important structure. Both techniques have advantages and limitations, and its use should be adapted to each specific clinical scenario. This article presents an up-to-date literature review regarding the use of ultrasound and magnetic resonance imaging in the forearm interosseous membrane evaluation. (orig.)

  13. The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Martin, Juan [Infanta Leonor University Hospital, Trauma and Orthopaedics, Shoulder and Elbow Unit, Madrid (Spain); Pretell-Mazzini, Juan [The Children' s Hospital of Philadelphia, Pediatric Orthopaedic Fellow, Division of Orthopaedic Surgery, Philadelphia, PA (United States)

    2011-12-15

    The interosseous membrane of the forearm is an important structure to consider in cases of elbow and forearm trauma; it can be injured after elbow or forearm fractures, leading to longitudinal forearm instability. Diagnosis of interosseous membrane injuries is challenging, and failure in diagnosis may result in poor clinical outcomes and complications. Magnetic resonance imaging and ultrasound have shown to be valuable methods for the evaluation of this important structure. Both techniques have advantages and limitations, and its use should be adapted to each specific clinical scenario. This article presents an up-to-date literature review regarding the use of ultrasound and magnetic resonance imaging in the forearm interosseous membrane evaluation. (orig.)

  14. Evaluation of chondromalacia of the patellofemoral compartment with axial magnetic resonance imaging.

    Science.gov (United States)

    Brown, T R; Quinn, S F

    1993-01-01

    Axial magnetic resonance (MR) imaging of the patellofemoral compartment was performed in 75 patients with arthroscopic correlation. Proton density and T2(2500/20/80) weighted images were obtained in all patients. Chondromalacia in stages I and II could not be reliably identified with MR imaging. For the evaluation of stage III and IV chondromalacia, the accuracy of MR was 89%. Focal or diffuse areas of increased or decreased signal alterations of the hyaline cartilage without a contour deformity or cartilaginous thinning do not correlate reliably with arthroscopic staging of chondromalacia. A normal signal intensity is no assurance that softening of the cartilage is not present. The most reliable indicators of chondromalacia are focal contour irregularities of the hyaline cartilage and/or thinning of the hyaline cartilage associated with high signal intensity changes within frank defects or contour irregularities with T2-weighted images. The poor MR-arthroscopic correlation in earlier stages of chondromalacia may be due in part to the subjective basis of the arthroscopic diagnosis. In conclusion, stage I and II chondromalacia of the patellofemoral compartment cannot be reliably evaluated with MR imaging. Stage III and IV chondromalacia is reliably evaluated with MR using the combination of proton density and T2-weighted images.

  15. Healing of the Achilles tendon in rabbits--evaluation by magnetic resonance imaging and histopathology.

    Science.gov (United States)

    Tavares, Wilson Campos; de Castro, Ubiratam Brum; Paulino, Eduardo; Vasconcellos, Leonardo de Souza; Madureira, Ana Paula; Magalhães, Maria Angélica Baron; Mendes, Daniel Victor Moreira; Kakehasi, Adriana Maria; Resende, Vivian

    2014-12-12

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) could provide valuable findings for tendon regeneration. A non-invasive image method that can effectively evaluate the quality of the scar tissue has not yet been employed. Thirteen New Zealand rabbits were divided into two groups: group 1--non-treated control (n = 4); group 2--surgical intervention (n = 9). The central portion of the Achilles tendon was resected, and after 30 days, DCE-MRI was performed. Contrast enhancement methods were applied using the region of interest (ROI) technique. In the medium third of the Achilles tendon, the intra-substantial signal intensity and the presence of hyper-intense intra-tendon focus points and of signal heterogeneity were evaluated. Antero-posterior and transversal diameters of the tendon were measured. The Achilles tendon was removed and dissected free from other tissues. Sections from the central part of the tendon were stained for histological analysis. The difference between the contrast enhancement curves of the control and surgical groups (p tendon sheath, which presented irregular contours and intense contrast enhancement. On histology, the Achilles tendon presented diffuse widening of the tendon sheath and wedge-shaped areas with scarring tissue rich in disordered collagen fibres. These findings were related to alteration in the intra-substantial signal intensity, with hyper-signal focus points in the DCE-MRI. MRI with perfusion could be a useful technique for evaluating tissue and fibrous scarring in tendons.

  16. Evaluation of chondromalacia of the patellofemoral compartment with axial magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.R. (Dept. of Radiology, Oregon Health Sciences Univ., Portland, OR (United States)); Quinn, S.F. (Dept. of Radiology, Good Samaritan Hospital and Medical Center, Portland, OR (United States))

    1993-01-01

    Axial magnetic resonance (MR) imaging of the patellofemoral compartment was performed in 75 patients with arthroscopic correlation. Proton density and T2(2500/20/80) weighted images were obtained in all patients. Chondromalacia in stages I and II could not be reliably identified with MR imaging. For the evaluation of stage III and IV chondromalacia, the accuracy of MR was 89%. Focal or diffuse areas of increased or decreased signal alterations of the hyaline cartilage without a contour deformity or cartilaginous thinning do not correlate reliably with arthrosopic staging of chondromalacia. A normal signal intensity is no assurance that softening of the cartilage is not present. The most reliable indicators of chondromalacia are focal contour irregularities of the hyaline cartilage and/or thinning of the hyaline cartilage associated with high signal intensity changes within frank defects or contour irregularities with T2-weighted images. The poor MR-arthroscopic correlation in earlier stages of chondromalacia may be due in part to the subjective basis of the arthroscopic diagnosis. In conclusion, stage I and II chondromalacia of the patellofemoral compartment cannot be reliably evaluated with MR imaging. Stage III and IV chondromalacia is reliably evaluated with MR using the combination of proton density and T2-weighted images. (orig.)

  17. Evaluation of Physic-chemical Parameters of Water Quality on Agricultural Fields of Western Bahia

    Directory of Open Access Journals (Sweden)

    Enoc Lima do Rego

    2017-06-01

    Full Text Available For the diagnosis of the quality of water it is necessary to execute a set of analyzes (physical and chemical of the body of water that will provide information that integrate biotic and abiotic factors that govern the functioning of the ecosystem. The objective of this study is to evaluate the quality of water from wells and rivers of Urucuia aquifer region for investigation of contamination or contamination risks. Were realize collections in nine (9 areas of western Bahia, which were collect in each area, two points of well water samples and a river, and determining the electrical conductivity, pH, dissolved ions and metals. The results were compare with the maximum permissible values (MPV for human consumption by Ordinance No. 2914/11 of the Ministry of Health and National Environment Counsel - CONAMA (Resolution 357 and supplementary resolutions. The quantitative results of the analysis showed that the surface and well waters that are part of the aquifer Urucuia within the parameters investigated are below the values recommended by the legislation showing that the agricultural activities in the region has not affected to the evaluated parameters, the quality of water for human consumption. However, it is necessary a monitoring of surface and groundwater in the region with expansion parameters evaluated. DOI: http://dx.doi.org/10.17807/orbital.v9i2.880

  18. Various problems concerning radioactive waste disposal sites and parameters for their evaluation

    International Nuclear Information System (INIS)

    Fukui, Masami

    1990-01-01

    The present report first describes various methods used for low-level radioactive waste disposal in the U.S. and then discusses major factors affecting the parameters used for quantitative evaluation of the behavior of radioactive nuclides existing in the environment, focusing on the distribution coefficient which is assumed in a model widely used for such evaluation. Some problems encountered in applying these parameters to practical evaluation are also discussed together with further studies required in the future. The distribution coefficient varies with many physical, chemical and biological factors, and it may be unavoidable to rely on experiments with a simplified system in determining the effect of each factor separately. However, the values obtained from such experiments cannot be used as parameters to reflect the behaviors of these nuclides in real environments. They should be considered as such. Efforts should be made to develop techniques to obtain effective values for the distribution coefficient that properly reflect their behaviors in real environments near disposal sites or in far fields. (N.K.)

  19. Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Moerland, Marinus A.; Wijrdeman, Harm K.; Beersma, Robert; Bakker, Chris J.G.; Battermann, Jan J.

    1997-01-01

    Purpose: The aim of this study is the evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging (MRI). Methods and Materials: Twenty-one patients underwent radiography on the simulator and MRI within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the seed-induced signal voids on MRI provided the seed positions in relation to the prostate. The prostate was contoured on the transversal magnetic resonance images, and dose-volume histograms were computed to evaluate the implants. The validity of the ellipsoidal prostate volume approximation, as applied in preimplant dose calculation, was assessed by comparison of ellipsoidal volumes given by prostate width, height, and length and prostate volumes obtained by a slice-by-slice contouring method, both on postimplant MRI. Prostate volume changes due to postimplant prostate swelling were assessed from radiographs taken at 3 days and 1 month after the implantation. Results: The seeds were readily identified on T 1 -weighted spin-echo images and matched with the seed distribution reconstructed from the isocentric radiographs. The matching error, averaged over 21 patients, amounted to 1.8 ± 0.4 mm (mean ± standard deviation). The fractions of the prostate volumes receiving the prescribed matched peripheral dose (MPD) ranged from 32 to 71% (mean ± standard deviation: 60 ± 10%). Prostate volumes, obtained by the contouring method on postimplant MRI, were a factor 1.5 ± 0.3 larger than the ellipsoidal volumes given by the prostate dimensions on postimplant MRI. Prostate volumes 3 days after the implantation were a factor 1.3 ± 0.2 larger than the prostate volumes 1 month after the implantation. Registration of the reconstructed seed distribution and the MR images showed inaccuracies in seed placement, for example, two or more seeds clustering together or seeds outside the prostate

  20. Evaluation of valvular regurgitation by cine magnetic resonance imaging in patients with various cardiac diseases

    International Nuclear Information System (INIS)

    Kubota, Shuuhei; Nishimura, Tsunehiko

    1990-01-01

    In order to evaluate the clinical value and limitation of magnetic resonance imaging (MRI) for detection and quantification of valvular regurgitation, 98 patients with various cardiac diseases were studied by cine MRI and the results were compared with contrast angiography and doppler color-flow imaging. Cine MRI was carried out using FLASH (fast low angle shot) which employs TE of 10∼20 msec and TR of 30∼40 msec. 22 transverse tomograms per cardiac cycle with a slice thickness of 10 mm were obtained at the level of atrium and ventricle. The jet of valvular regurgitation was easily seen as a discrete are of low signal with cine MRI. Identification of the regurgitation and its severity were visually evaluated based on the relative size of the regurgitant jet from the incompetent valve orifice. Using contrast angiography as a gold standard, the sensitivity of cine MRI for detecting mitral regurgitation was 83% and was 94% for aortic regurgitation, with the specificity of 82% and 100%, respectively. For mitral requrgitation and aortic regurgitation, evaluation by cine MRI and severity agreed well with contrast angiography. By the comparative study with doppler color-flow imaging, relatively good agreement was found between the two methods in detection and quantitative evaluation of valvular regurgitation in any of four valves. Cine MRI was suggested to be useful for both the detection and semiquantification of valvular regurgitation in generally, but its clinical limitation at this point was also found because, 1)its images are not acquired in real times, as in contrast angiography or doppler color-flow imaging, but are compiled from the cumulative information from 128 heart beats, 2)the evaluation of regurgitation is made from only two-dimensional transverse tomograms. (author)

  1. Evaluation of breast implants with breast magnetic resonance: Practical utility in comparison with other methods

    International Nuclear Information System (INIS)

    Melendez, Florencia; Blejman, Oscar; Lamattina Mariano; Villamea, Victoria; Sarquis, Flavio; Torrillo, Fabiana

    2010-01-01

    The purpose of this study was to demonstrate the utility of Breast Magnetic Resonance (BMR) in the evaluation of breast implants comparing Mammography and Breast ultrasound in an ambulatory private institute setting. Method: Between May 2008 and April 2010, 729 BRM were performed in patients between 22 and 77 years of age, 474 were evaluated for implant integrity. The studies were performed in a high field equipment (1.5T) with T1, T2, fat Sat, Silicone only and silicone suppression sequences. Results: Of the 474 patients that were evaluated for implant integrity: 291 patients (61.39%) presented with intact implants, 252 (86.6%) showed concordant findings with mammography and or ultrasound and 39 (13.4%) showed discordant findings. Then, 116 patients (24.47%) presented signs of intracapsular rupture, 82 (70.7%) were concordant with ultrasound findings and 34 (29.3%) had normal ultrasound evaluation. 44 patients (9.28%) presented extracapsular rupture, 40 (90.9%) were concordant with mammography and ultrasound and 4 (9.10%) were discordant. Finally, 23 patients (4.85%) presented residual silicone granulomas, with history of previous implant rupture and explanted surgery, 13 (56.52%) concordant with mammography and ultrasound and 10 (43.48%) were discordant. Conclusion: Non contrast BMR, using multiples planes and sequences is very useful in the evaluation of the internal structure of the implants and extracapsular silicone. It's the most sensible study to demonstrate intra and extracapsular rupture. BMR exceeds mammography and ultrasound in the detection of implant rupture and residual granulomas following explanted surgery.

  2. EVALUATION OF ANAEMIA USING RED CELL AND RETICULOCYTE PARAMETERS USING AUTOMATED HAEMATOLOGY ANALYSER

    Directory of Open Access Journals (Sweden)

    Vidyadhar Rao

    2016-06-01

    Full Text Available Use of current models of Automated Haematology Analysers help in calculating the haemoglobin contents of the mature Red cells, Reticulocytes and percentages of Microcytic and hypochromic Red cells. This has helped the clinician in reaching early diagnosis and management of Different haemopoietic disorders like Iron Deficiency Anaemia, Thalassaemia and anaemia of chronic diseases. AIM This study is conducted using an Automated Haematology Analyser to evaluate anaemia using the Red Cell and Reticulocyte parameters. Three types of anaemia were evaluated; iron deficiency anaemia, anaemia of long duration and anaemia associated with chronic disease and Iron deficiency. MATERIALS AND METHODS The blood samples were collected from 287 adult patients with anaemia differentiated depending upon their iron status, haemoglobinopathies and inflammatory activity. Iron deficiency anaemia (n=132, anaemia of long duration (ACD, (n=97 and anaemia associated with chronic disease with iron deficiency (ACD Combi, (n=58. Microcytic Red cells, hypochromic red cells percentage and levels of haemoglobin in reticulocytes and matured RBCs were calculated. The accuracy of the parameters was analysed using receiver operating characteristic analyser to differentiate between the types of anaemia. OBSERVATIONS AND RESULTS There was no difference in parameters between the iron deficiency group or anaemia associated with chronic disease and iron deficiency. The hypochromic red cells percentage was the best parameter in differentiating anaemia of chronic disease with or without absolute iron deficiency with a sensitivity of 72.7% and a specificity of 70.4%. CONCLUSIONS The parameters of red cells and reticulocytes were of reasonably good indicators in differentiating the absolute iron deficiency anaemia with chronic disease.

  3. Incorporating doubly resonant $W^\\pm$ data in a global fit of SMEFT parameters to lift flat directions

    CERN Document Server

    Berthier, Laure; Trott, Michael

    2016-09-27

    We calculate the double pole contribution to two to four fermion scattering through $W^{\\pm}$ currents at tree level in the Standard Model Effective Field Theory (SMEFT). We assume all fermions to be massless, $\\rm U(3)^5$ flavour and $\\rm CP$ symmetry. Using this result, we update the global constraint picture on SMEFT parameters including LEPII data on these charged current processes, and also include modifications to our fit procedure motivated by a companion paper focused on $W^{\\pm}$ mass extractions. The fit reported is now to 177 observables and emphasises the need for a consistent inclusion of theoretical errors, and a consistent treatment of observables. Including charged current data lifts the two-fold degeneracy previously encountered in LEP (and lower energy) data, and allows us to set simultaneous constraints on 20 of 53 Wilson coefficients in the SMEFT, consistent with our assumptions. This allows the model independent inclusion of LEP data in SMEFT studies at LHC, which are projected into the S...

  4. Detecting differences in some elite wheat lines for salt tolerance through multi parameters evaluation i. morphological and yield parameters

    International Nuclear Information System (INIS)

    Akram, M.; Afzal, M.; Ashraf, M.

    2011-01-01

    Salt tolerance potential of a newly developed wheat genotype (N-9760: V3) was assessed by comparing it with a known salt tolerant line (N-1073:V2) and a commercial cultivar (Inqlab: V1) using various growth parameters measured at the vegetative and maturity stages, The objectives were to know qualitative and quantitative tolerance status and possible utilization of the new genotype as well as to examine as to whether the parameters used to assess the tolerance at vegetative and maturity stages are affected differentially by various salinity levels. The experiment was conducted in pots using four salinity levels (EC 1.5, 5, 10 and 15 dS m/sup -1/). Root and shoot length, root and shoot fresh and dry weight, number of leaves and leaf area were recorded at the vegetative stage, while plant height, number of tillers, spike length and grain yield plant/sup -1/ were recorded at the maturity stage. Fresh weight of shoots, fresh and dry weights of roots, plant height, number of productive tillers and grain yield were least affected in V3 while shoot length, shoot fresh weight, number of leaves, leaf area and spike length were least affected in V2 by EC 15 dS m/sup -1/. Both genotypes appeared tolerant but all the parameters studied at both stages were affected differentially by salinity levels and genotypes hence, testing of every new genotype appeared essential. (author)

  5. Modifications in Dynamic Contrast-Enhanced Magnetic Resonance Imaging Parameters After α-Particle-Emitting {sup 227}Th-trastuzumab Therapy of HER2-Expressing Ovarian Cancer Xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Heyerdahl, Helen, E-mail: Helen.Heyerdahl@rr-research.no [Department of Radiation Biology, Institute for Cancer Research, Oslo University Hospital - The Norwegian Radium Hospital, Oslo (Norway); Røe, Kathrine [Department of Oncology, Division of Medicine, Akershus University Hospital, Lørenskog (Norway); Brevik, Ellen Mengshoel [Department of Research and Development, Algeta ASA, Oslo (Norway); Dahle, Jostein [Nordic Nanovector AS, Oslo (Norway)

    2013-09-01

    Purpose: The purpose of this study was to investigate the effect of α-particle-emitting {sup 227}Th-trastuzumab radioimmunotherapy on tumor vasculature to increase the knowledge about the mechanisms of action of {sup 227}Th-trastuzumab. Methods and Materials: Human HER2-expressing SKOV-3 ovarian cancer xenografts were grown bilaterally in athymic nude mice. Mice with tumor volumes 253 ± 36 mm{sup 3} (mean ± SEM) were treated with a single injection of either {sup 227}Th-trastuzumab at a dose of 1000 kBq/kg body weight (treated group, n=14 tumors) or 0.9% NaCl (control group, n=10 tumors). Dynamic T1-weighted contrast-enhanced magnetic resonance imaging (DCEMRI) was used to study the effect of {sup 227}Th-trastuzumab on tumor vasculature. DCEMRI was performed before treatment and 1, 2, and 3 weeks after therapy. Tumor contrast-enhancement curves were extracted voxel by voxel and fitted to the Brix pharmacokinetic model. Pharmacokinetic parameters for the tumors that underwent radioimmunotherapy were compared with the corresponding parameters of control tumors. Results: Significant increases of k{sub ep}, the rate constant of diffusion from the extravascular extracellular space to the plasma (P<.05), and k{sub el,} the rate of clearance of contrast agent from the plasma (P<.01), were seen in the radioimmunotherapy group 2 and 3 weeks after injection, compared with the control group. The product of k{sub ep} and the amplitude parameter A, associated with increased vessel permeability and perfusion, was also significantly increased in the radioimmunotherapy group 2 and 3 weeks after injection (P<.01). Conclusions: Pharmacokinetic modeling of MRI contrast-enhancement curves evidenced significant alterations in parameters associated with increased tumor vessel permeability and tumor perfusion after {sup 227}Th-trastuzumab treatment of HER2-expressing ovarian cancer xenografts.

  6. A lattice-based Monte Carlo evaluation of Canada Deuterium Uranium-6 safety parameters

    International Nuclear Information System (INIS)

    Kim, Yong Hee; Hartanto, Donny; Kim, Woo Song

    2016-01-01

    Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANada Deuterium Uranium (CANDU-6) reactor have been evaluated using the Monte Carlo method. For accurate analysis of the parameters, the Doppler broadening rejection correction scheme was implemented in the MCNPX code to account for the thermal motion of the heavy uranium-238 nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted using MCNPX. The FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated using several cross-section libraries such as ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1.1, and JENDL-4.0. The PCR value is also evaluated at mid-burnup conditions to characterize the safety features of an equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, we considered a huge number of neutron histories in this work and the standard deviation of the k-infinity values is only 0.5-1 pcm

  7. Dacryocystorhinostomy ostium: parameters to evaluate and DCR ostium scoring

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2014-12-01

    Full Text Available Mohammad Javed Ali,1 Alkis James Psaltis,2 Peter John Wormald2 1Dacryology Service, L V Prasad Eye Institute, Hyderabad, Telangana, India; 2Department of Surgery–Otorhinolaryngology, Head and Neck Surgery, The University of Adelaide, Adelaide, SA, Australia Aim: This study aims to provide a systematic protocol for the evaluation of a dacryocystorhinostomy (DCR ostium and to propose a scoring system to standardize the assessment.Methods: Retrospective evaluation of 125 consecutive lacrimal ostia post-DCR was performed. Medical records were screened, and photographs and videos were assessed to note the details of various ostial parameters. The major time points in evaluation were 4 weeks, 6 weeks, 3 months, and 6 months post-DCR. The ostia were defined and parameters like shape, size, location, and evolution of ostium were noted. Evaluation parameters were defined for internal common opening (ICO, ostium stents, and ostium granulomas. Ostium cicatrix and synechiae were graded based on their significance. Surgical success rates were computed and ostium characteristics in failed cases were studied.Results: A total of 125 ostia were evaluated on the aforementioned ostium parameters. Because five ostia showed a complete cicatricial closure with no recognizable features, the remaining 120 ostia were studied. The ostium location was anterior to the axilla of middle turbinate in 85.8% (103/120 of the cases. Moreover, 76.6% (92/120 of the ostia were circular to oval in shape, with a shallow base. The ostium size was >8×5 mm in 78.3% (94/120 of the cases. The ICO was found to be located in the central or paracentral basal area in 75.8% (91/120. The anatomical and functional success rates achieved were 96% and 93.6%, respectively. All the five cases with anatomical failures showed a complete cicatrization and the ICO movements were poor in all the three cases of functional failure.Conclusion: The article attempts to standardize the postoperative

  8. In Vitro Magnetic Resonance Imaging Evaluation of Fragmented, Open-Coil, Percutaneous Peripheral Nerve Stimulation Leads.

    Science.gov (United States)

    Shellock, Frank G; Zare, Armaan; Ilfeld, Brian M; Chae, John; Strother, Robert B

    2018-04-01

    Percutaneous peripheral nerve stimulation (PNS) is an FDA-cleared pain treatment. Occasionally, fragments of the lead (MicroLead, SPR Therapeutics, LLC, Cleveland, OH, USA) may be retained following lead removal. Since the lead is metallic, there are associated magnetic resonance imaging (MRI) risks. Therefore, the objective of this investigation was to evaluate MRI-related issues (i.e., magnetic field interactions, heating, and artifacts) for various lead fragments. Testing was conducted using standardized techniques on lead fragments of different lengths (i.e., 50, 75, and 100% of maximum possible fragment length of 12.7 cm) to determine MRI-related problems. Magnetic field interactions (i.e., translational attraction and torque) and artifacts were tested for the longest lead fragment at 3 Tesla. MRI-related heating was evaluated at 1.5 Tesla/64 MHz and 3 Tesla/128 MHz with each lead fragment placed in a gelled-saline filled phantom. Temperatures were recorded on the lead fragments while using relatively high RF power levels. Artifacts were evaluated using T1-weighted, spin echo, and gradient echo (GRE) pulse sequences. The longest lead fragment produced only minor magnetic field interactions. For the lead fragments evaluated, physiologically inconsequential MRI-related heating occurred at 1.5 Tesla/64 MHz while under certain 3 Tesla/128 MHz conditions, excessive temperature elevations may occur. Artifacts extended approximately 7 mm from the lead fragment on the GRE pulse sequence, suggesting that anatomy located at a position greater than this distance may be visualized on MRI. MRI may be performed safely in patients with retained lead fragments at 1.5 Tesla using the specific conditions of this study (i.e., MR Conditional). Due to possible excessive temperature rises at 3 Tesla, performing MRI at that field strength is currently inadvisable. © 2017 International Neuromodulation Society.

  9. The accuracy of computed tomography and magnetic resonance imaging in evaluating the extent of endometrial carcinoma

    International Nuclear Information System (INIS)

    Takahashi, Koichi; Yoshioka, Masuo; Kosuge, Hiroaki; Iizuka, Yoshihiro; Musha, Terunaga; Yamauchi, Itaru; Yoshimura, Yasunori; Nakamura, Yukio

    1995-01-01

    The present study was designed to determine the accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in evaluating the extent of the tumor in 36 patients with endometrial carcinoma. The CT and MRI findings were compared with the microscopic pathologic characteristics in all cases. Linear regression analysis for measurements of residual normal myometrium revealed significant positive correlations (p<0.001) between MRI (r=0.861) and CT (r=0.826) findings and pathologic evaluation. Thirty-six patients were divided into two groups according to our previous CT and MRI criteria: the superficial myometrial invasion group and advanced tumor group. In MRI findings, higher incidences of deep (≥1/2) myometrial invasion (p<0.001), vessel permeation (p<0.05) and cervical involvement (p<0.05) were observed in the advanced group. In CT findings, deep myometrial invasion (p<0.001) was observed in the advanced group. The incidence of extrauterine extension of the tumor did not differ significantly between CT and MRI findings. The accuracy figures for cervical involvement evaluated by CT and MRI were 83%, and 86%, respectively. In four of 6 patients, in whom an intact Junctional zone (j-zone) was detected by MRI, the tumor was localized in the endometrium. The remaining 2 patients had only superficial myometrial invasion histologically. In all 16 patients, in whom the j-zone was interrupted in MRI findings, myometrial invasion was confirmed pathologically. In conclusion, the present study demonstrates that the overall accuracy of MRI staging in patients with endometrial carcinoma is 61.1%, and CT, as well as MRI, is effective preoperatively in evaluating the extent of the tumor. (author)

  10. Evaluation of late stage iatrogenic extrahepatic bile duct stricture by using magnetic resonance cholangiopancreagraphy

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Liu Rongbo; Song Bin; Yan Zhihan; Chen Xian; Wang Wentao; Xiong Yan; Xu Minsheng; Gu Jianping

    2003-01-01

    Objective: To assess the role of magnetic resonance cholangiopancreagraphy (MRCP) in the preoperative evaluation of late stage iatrogenic extrahepatic bile duct stricture. Methods: Eighteen cases, which were diagnosed as late stage iatrogenic extrahepatic bile duct strictures only by MRCP and proved by surgery and pathology, were classified according to Bismuth classification and the surgical operation strategy was planed on the basis of MR cholangiopancreagraphic findings before surgery. The results were compared with surgery. Results: Diagnostic MR Cholangiopancreagrams were acquired in 18 patients. Among all 18 patients, the level of stricture was classified as Bismuth I in 3 patients, Bismuth II in 7 patients, Bismuth III in 3 patients, and Bismuth IV in 3 patients. A Bismuth II stricture was incorrectly classified as a Bismuth III lesion. On the basis of MR cholangiopancreagraphic findings, a surgical operation strategy can be planed. The therapeutic plan anticipated with MRCP matched the actually used procedure in 16 of 18 patients. conclusion: MRCP plays an important role in the evaluation of late stage iatrogenic extrahepatic bile duct stricture

  11. Magnetic resonance cisternography using the fast spin echo method for the evaluation of vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Shigeru; Yokoyama, Tetsuo; Uemura, Kenichi [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Neuroimaging of vestibular schwannoma was performed with the fat-suppression spoiled gradient recalled acquisition in the steady state (SPGR) method and magnetic resonance (MR) cisternography, which is a fast spin echo method using a long echo train length, for the preoperative evaluation of the lateral extension of the tumor in the internal auditory canal, and the anatomical identification of the posterior semicircular canal and the nerves in the canal distal to the tumor. The SPGR method overestimated the lateral extension in eight cases, probably because of enhancement of the nerves adjacent to the tumor in the canal. The posterior semicircular canal could not be clearly identified, and the cranial nerves in the canal were shown only as a nerve bundle. In contrast, MR cisternography showed clear images of the lateral extension of the tumor and the facial and cochlear nerves adjacent to the tumor in the internal auditory canal. The anatomical location of the posterior semicircular canal was also clearly shown. These preoperative findings are very useful to plan the extent to which the internal auditory canal can be opened, and for intraoperative identification of the nerves in the canal. MR cisternography is less invasive since no contrast material or radiation is required, as with thin-slice high-resolution computed tomography (CT). MR cisternography should replace high-resolution CT for the preoperative neuroradiological evaluation of vestibular schwannoma. (author)

  12. Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Beom; Koh, Kwang Joon [School of Dentistry, Chonbuk National University, Chonju (Korea, Republic of)

    2002-06-15

    To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  13. Evaluation of cardiac motion and function by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kondo, Takeshi; Kurokawa, Hiroshi; Anno, Hirofumi

    1992-01-01

    Cardiac cine magnetic resonance imaging (MRI) was studied to evaluate the cardiac motion and function, and a water-stream phantom study was performed to clarify whether it was possible to quantitatively assess the valvular regurgitation flow by the size of the flow void. In normal subjects, the left ventricular (LV) epicardial apex swung up to the base only a few millimeters, and the mitral annulus ring moved about 14 mm as mean value toward the apex during systole. Those motions of mitral annulus ring may contribute to the left atrial filling. The LV longitudinal shortening and torsions were shown by the tagging method. This tagging method was the best method for estimating cardiac motions. Cardiac cine MRI using software including a modified Simpson's method program and a wall motion analysis program was useful for routine LV volumetry and wall motion analysis because it was a simple and reliable method. Our water-stream phantom studies demonstrated that it might be difficult to perform quantitative evaluation of valvular regurgitation flow by using only the size of the flow void without acquiring information relating to the orifice area. (author)

  14. Evaluation of colonic involvement in endometriosis: double-contrast barium enema vs. magnetic resonance imaging.

    Science.gov (United States)

    Faccioli, N; Foti, G; Manfredi, R; Mainardi, P; Spoto, E; Ruffo, G; Minelli, L; Mucelli, R Pozzi

    2010-08-01

    The purpose of the study was to compare the accuracy of double-contrast barium enema (DCBE) and magnetic resonance imaging (MRI) in the diagnosis of intestinal endometriosis using the histological examination on resected specimen as comparative standard. Eighty-three consecutive patients with suspected intestinal endometriosis, resected between 2005 and 2007, were prospectively evaluated. All of the women underwent preoperative DCBE and MRI on the same day. We evaluated number, site (rectum, sigmoid, cecum), and size of the lesions. The imaging findings were correlated with those resulting at pathology. Among the 65 women who underwent surgery, 50/65 (76.9%) were found to have bowel endometriosis, with 9/50 (18%) patients presenting two lesions; DCBE allowed to detect 50/59 (84.7%) lesions. MRI allowed to detect 42/59 (71.1%) lesions. DCBE showed sensibility, specificity, PPV, NPV, and accuracy of respectively 84.7, 93.7, 98.0, 62.5, and 86.6%, MRI of 71.1, 83.3, 93.3, 46.8, and 74.6%. DCBE is more accurate than unenhanced MRI in the diagnosis of bowel endometriosis, and should be preferred in the preoperative management of this disease, since it usually enables a proper surgical planning.

  15. Functional Magnetic Resonance Imaging in the Presurgical Evaluation of Brain Vascular Malformations

    International Nuclear Information System (INIS)

    Montes, Natalia; Herrera, Diego A; Vargas Sergio A

    2010-01-01

    Objective: To describe our experience in presurgical evaluation of intracranial vascular malformations by means of functional magnetic resonance (fMRI). Method: To evaluate eight patients with cerebral vascular malformations (seven arterio-venous malformation [AVM ] and one cavernous malformation) to send to the eloquent cortex with RMf pre-surgical mapping is assessed. Used a technique that is dependent on the level of oxygen (BOLD) to locate these areas in the cerebral vascular malformation, by applying different paradigms. Results: We found one AVM at the right temporal lobe with activation of the parahipocampal gyrus at the contralateral side using a memory paradigm; another patient with an AVM at the right mesotemporal lobe showed activation of visual and spatial memory of the contralateral hippocampus and parahippocampus. One patient with an AVM at the left parietal lobe without compromise of sensorial and motor cortex; a cavernous malformation at the left angular gyrus with hemispheric language dominance in that side; one right thalamic AVM, one periventricular AVM bilateral language dominance; one left occipital AVM with decreased activation in visual association cortex; one temporoccipital AVM with left language dominance and neurovascular uncoupling. Conclusion: fMRI can delineate anatomically the relationship between the lesion and eloquent cortex, providing useful information for presurgical planning and allowing risk estimation of intervention.

  16. Quantitative morphologic evaluation of magnetic resonance imaging during and after treatment of childhood leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Reddick, Wilburn E.; Glass, John O. [St. Jude Children' s Research Hospital, Division of Translational Imaging Research (MS 210), Department of Radiological Sciences, Memphis, TN (United States); Laningham, Fred H. [St. Jude Children' s Research Hospital, Division of Diagnostic Imaging, Memphis, TN (United States); Pui, Ching-Hon [St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States)

    2007-11-15

    Medical advances over the last several decades, including CNS prophylaxis, have greatly increased survival in children with leukemia. As survival rates have increased, clinicians and scientists have been afforded the opportunity to further develop treatments to improve the quality of life of survivors by minimizing the long-term adverse effects. When evaluating the effect of antileukemia therapy on the developing brain, magnetic resonance (MR) imaging has been the preferred modality because it quantifies morphologic changes objectively and noninvasively. Computer-aided detection of changes on neuroimages enables us to objectively differentiate leukoencephalopathy from normal maturation of the developing brain. Quantitative tissue segmentation algorithms and relaxometry measures have been used to determine the prevalence, extent, and intensity of white matter changes that occur during therapy. More recently, diffusion tensor imaging has been used to quantify microstructural changes in the integrity of the white matter fiber tracts. MR perfusion imaging can be used to noninvasively monitor vascular changes during therapy. Changes in quantitative MR measures have been associated, to some degree, with changes in neurocognitive function during and after treatment. In this review, we present recent advances in quantitative evaluation of MR imaging and discuss how these methods hold the promise to further elucidate the pathophysiologic effects of treatment for childhood leukemia. (orig.)

  17. Quantitative morphologic evaluation of magnetic resonance imaging during and after treatment of childhood leukemia

    International Nuclear Information System (INIS)

    Reddick, Wilburn E.; Glass, John O.; Laningham, Fred H.; Pui, Ching-Hon

    2007-01-01

    Medical advances over the last several decades, including CNS prophylaxis, have greatly increased survival in children with leukemia. As survival rates have increased, clinicians and scientists have been afforded the opportunity to further develop treatments to improve the quality of life of survivors by minimizing the long-term adverse effects. When evaluating the effect of antileukemia therapy on the developing brain, magnetic resonance (MR) imaging has been the preferred modality because it quantifies morphologic changes objectively and noninvasively. Computer-aided detection of changes on neuroimages enables us to objectively differentiate leukoencephalopathy from normal maturation of the developing brain. Quantitative tissue segmentation algorithms and relaxometry measures have been used to determine the prevalence, extent, and intensity of white matter changes that occur during therapy. More recently, diffusion tensor imaging has been used to quantify microstructural changes in the integrity of the white matter fiber tracts. MR perfusion imaging can be used to noninvasively monitor vascular changes during therapy. Changes in quantitative MR measures have been associated, to some degree, with changes in neurocognitive function during and after treatment. In this review, we present recent advances in quantitative evaluation of MR imaging and discuss how these methods hold the promise to further elucidate the pathophysiologic effects of treatment for childhood leukemia. (orig.)

  18. Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint

    International Nuclear Information System (INIS)

    Cho, Soo Beom; Koh, Kwang Joon

    2002-01-01

    To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  19. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  20. Magnetic resonance evaluation of cerebral toxoplasmosis in patients with the acquired immunodeficiency syndrome

    International Nuclear Information System (INIS)

    Batra, A; Tripathi, R.P.; Gorthi, S.P.

    2004-01-01

    PURPOSE: To evaluate and delineate the characteristics of cerebral toxoplasmosis lesions using a combination of magnetic resonance (MR) spectroscopy, diffusion, and perfusion studies. MATERIAL AND METHODS: A total of 8 patients with 23 lesions were evaluated on a 1.5-T MR system. Diffusion-weighted imaging (DWI) was performed with three 'b' values of 50, 500, and 1000 s/mm2, and the apparent diffusion coefficient maps were calculated. The diffusion-weighted appearances and the T2-weighted MR appearances of the lesions were compared. MR spectroscopy was performed using the point-resolved single-voxel technique with two TE values of 135 ms and 270 ms. Perfusion studies were carried out using the dynamic contrast-enhanced technique, and the relative cerebral blood volume maps were qualitatively and quantitatively analyzed. RESULTS: DWI revealed the majority of the lesions as having increased diffusion within their necrotic centers, with the ADC ranging from 0.5 to 3.01 (mean ± SD: 1.49 ± 0.7). All the lesions revealed a predominant lipid peak on MR spectroscopy and were extremely hypovascular on perfusion MR studies. CONCLUSION: MR diffusion, spectroscopy, and perfusion studies help in characterizing toxoplasmosis lesions and, in most cases, can be used in combination to help establish the diagnosis of toxoplasmosis

  1. Magnetic resonance evaluation of cerebral toxoplasmosis in patients with the acquired immunodeficiency syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Batra, A; Tripathi, R.P.; Gorthi, S.P. [Inst. of Nuclear Medicine and Allied Sciences, Delhi (India). NMR Research Center

    2004-04-01

    PURPOSE: To evaluate and delineate the characteristics of cerebral toxoplasmosis lesions using a combination of magnetic resonance (MR) spectroscopy, diffusion, and perfusion studies. MATERIAL AND METHODS: A total of 8 patients with 23 lesions were evaluated on a 1.5-T MR system. Diffusion-weighted imaging (DWI) was performed with three 'b' values of 50, 500, and 1000 s/mm2, and the apparent diffusion coefficient maps were calculated. The diffusion-weighted appearances and the T2-weighted MR appearances of the lesions were compared. MR spectroscopy was performed using the point-resolved single-voxel technique with two TE values of 135 ms and 270 ms. Perfusion studies were carried out using the dynamic contrast-enhanced technique, and the relative cerebral blood volume maps were qualitatively and quantitatively analyzed. RESULTS: DWI revealed the majority of the lesions as having increased diffusion within their necrotic centers, with the ADC ranging from 0.5 to 3.01 (mean {+-} SD: 1.49 {+-} 0.7). All the lesions revealed a predominant lipid peak on MR spectroscopy and were extremely hypovascular on perfusion MR studies. CONCLUSION: MR diffusion, spectroscopy, and perfusion studies help in characterizing toxoplasmosis lesions and, in most cases, can be used in combination to help establish the diagnosis of toxoplasmosis.

  2. Cardiac magnetic resonance imaging in evaluation of anatomical structure and function of the ventricles

    International Nuclear Information System (INIS)

    Suzuki, Jun-ichi; Usui, Masahiro; Takenaka, Katsu

    1990-01-01

    Cardiac magnetic resonance imaging (MRI) is being widely employed for evaluation of cardiovascular anatomies and functions. However, the indications for cardiac MRI to obtain information which cannot be obtained using other conventional methods have not yet been determined. To demonstrate the usefulness of MRI in delineating the apex of the left ventricle and free wall of the right ventricle, end-diastolic short axis MRI images were obtained in 20 patients with apical hypertrophy and in 9 normal volunteers. To compare the accuracy of estimations of left ventricular volumes obtained using the modified Simpson's method of MRI with that using the MRI area length method, 19 patients, in whom left ventriculography had been performed, were studied. The apex of the left ventricle was evaluated circumferentially and distribution of hypertrophied muscles was defined. Sixty-five percent of the length of the right ventricular free wall was clearly delineated. Correlation coefficients of the ejection fraction between MRI and angiography were 0.85 with the modified Simpson's method of MRI, and 0.62 with the area length method of MRI. Three themes were chosen to demonstrate good clinical indications for cardiac MRI. (author)

  3. Magnetic resonance imaging for stress incontinence: evaluation of patients before and after surgical correction

    Energy Technology Data Exchange (ETDEWEB)

    Perk, Hakki E-mail: hakkiperk@yahoo.com; Oral, Baha; Yesildag, Ahmet; Serel, T. Ahmet; Oezsoy, Mesut; Turgut, Tayfun

    2002-10-01

    Objective: The purpose of this study was to evaluate the accuracy of magnetic resonance imaging (MRI) in the pre and postoperative assessment of stress urinary incontinence. Methods: Fifteen female patients with clinical evidence of stress urinary incontinence were included in this prospective study. All the patients underwent MRI in the supine position both preoperatively and postoperatively. For imaging, we used a 1.0 T magnet, T2-weighted images were obtained in the midline sagittal plane with patients at rest. Images were evaluated for anatomical stress urinary incontinence alterations, such as the increased distance between the pubococcygeal line and the bladder base and the posterior urethro-vesical angle and the urethral inclination angle changes. Wilcoxon signed rank test allowed comparisons of pre and postoperative results. Results: Compared with postoperative measurements, the bladder base was lowered significantly by an average of 9.4{+-}4.0 mm (P<0.01), posterior urethro-vesical angle was significantly increased by an average of 127.8{+-}11.4 deg. (P<0.01), and the urethral inclination angle was significantly increased by an average of 54.9{+-}10.1 deg. (P<0.01) preoperatively. Conclusion: Our results suggest that MRI can play a major role in the preoperative and postoperative assessment of stress urinary incontinence. It can reliably detect anatomical urinary incontinence alterations. MRI should be considered in failed surgery, complex prolapse, and in differentiating genuine stress incontinence resulting from malposition of the bladder neck from stress incontinence due to intrinsic urethral damage.

  4. Experimental evaluation of local bubble parameters of subcooled boiling flow in a pressurized vertical annulus channel

    Energy Technology Data Exchange (ETDEWEB)

    Chu, In-Cheol, E-mail: chuic@kaeri.re.kr; Lee, Seung-Jun; Youn, Young Jung; Park, Jong Kuk; Choi, Hae Seob; Euh, Dong-Jin; Song, Chul-Hwa

    2017-02-15

    Experiments were performed to quantify the local bubble parameters such as void fraction, bubble velocity, interfacial area concentration, and Sauter mean diameter for the subcooled boiling flow of a refrigerant R-134a in a pressurized vertical annulus channel. Optical fiber void probe and double pressure boundary visualization windows were installed at four measurement stations with different elevations, thus enabling the quantification of local bubble parameters and observation of global boiling structure. Using high-resolution traverse systems for the optical fiber void probes and the heating tube, the radial profiles of the bubble parameters and their axial propagation can be evaluated at any elevation of the whole heating region. At this first phase of the experiments, three tests were conducted by varying the pressure, heat flux, mass flux, and local liquid subcooling. The radial profiles of the bubble parameters were obtained at seven elevations. The pressure condition of the present experiments covered the normal operating pressure of PWRs according to the similarity criteria. The present experimental data will be useful for thorough validation and improvement of the CMFD (Computation Multi-Fluid Dynamics) codes and constitutive relations.

  5. Stochastic estimation approach for the evaluation of thermal-hydraulic parameters in pressurized water reactors

    International Nuclear Information System (INIS)

    Shieh, D.J.; Upadhyaya, M.G.

    1986-01-01

    A method based on the extended Kalman filter is developed for the estimation of the core coolant mass flow rate in pressurized water reactors. The need for flow calibration can be avoided by a direct estimation of this parameter. A reduced-order neutronic and thermal-hydraulic model is developed for the Loss-of-Fluid Test (LOFT) reactor. The neutron detector and core-exit coolant temperature signals from the LOFT reactor are used as measurements in the parameter estimation algorithm. The estimation sensitivity to model uncertainties was evaluated using the ambiguity function analysis. This also provides a lower bound on the measurement sample size necessary to achieve a certain estimation accuracy. A sequential technique was developed to minimize the computational effort needed to discretize the continuous time equations, and thus achieve faster convergence to the true parameter value. The performance of the stochastic approximation method was first evaluated using simulated random data, and then applied to the estimation of coolant flow rate using the operational data from the LOFT reactor at 100 and 65% flow rate conditions

  6. Transport of radionuclides in stochastic media: 2. evaluation of the parameters

    International Nuclear Information System (INIS)

    Smidts, O.F.

    1996-01-01

    This paper shows how we may evaluate in a hydrogeological context (i.e. with hypotheses and parameters commonly encountered in hydrogeology) the different coefficients introduced in the three-dimensional quasi-asymptotic equation found previously (see this issue). The evaluation is based on stochastic models developed in hydrogeology and based on field experiments. An analytical evaluation is made for a simple model of the velocity autocorrelation tensor. Numerical values of the coefficients are given. Next, we applied the model in planar geometry. Exact solutions of the quasi-asymptotic equation are shown in this case. In particular, we examined the differences between our model and the model of Williams in fractured rocks. (Author)

  7. Bonderenko self-shielded cross sections and multiband parameters derived from the LLL Evaluated-Nuclear-Data Library (ENDL)

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1978-01-01

    Bonderenko self-shielded cross sections and multiband parameters from the Lawrence Livermore Laboratory Evaluated-Nuclear-Data Library (ENDL) as of July 4, 1978 are presented. These data include total, elastic, capture, and fission cross sections in the TART 175 group structure. Multiband parameters are listed. Bonderenko self-shielded cross section and the multiband parameters are presented on microfiche

  8. Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance.

    Science.gov (United States)

    Edelman, Robert R; Serhal, Ali; Pursnani, Amit; Pang, Jianing; Koktzoglou, Ioannis

    2018-02-19

    Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow

  9. A Measurement of the Effective Electron Neutral Current Coupling Parameters from Polarized Bhabha Scattering at the Z0 Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Langston, Matthew D

    2003-07-15

    The effective electron neutral current coupling parameters, {bar g}{sub V}{sup 3} and {bar g}{sub A}{sup c}, have been measured from analyzing 43,222 polarized Bhabha scattered events (e{sup +}e{sup -} {yields} e{sup +}e{sup -}) using the SLAC Large Detector (SLD) experiment at the Stanford Linear Accelerator Center (SLAC). The SLAC Linear Collider (SLC) produced the Bhabha scattered events by colliding polarized electrons, with an average polarization of 74%, with unpolarized positrons at an average center-of-mass energy of 91.25 GeV. The analysis used the entire SLD data sample collected between 1994 and 1998 (the last year the SLD detector collected data). The results are {bar g}{sub V}{sup e} = -0.0469 {+-} 0.0024 (stat.) {+-} 0.0004 (sys.); {bar g}{sub A}{sup e} = -0.5038 {+-} 0.0010 (stat.) {+-} 0.0043 (sys.). All Bhabha scattered events within the angular acceptance of the SLD calorimeter subsystems were used in this analysis, including both small-angle events (28 mrad. {le} theta {le} 68 mrad.) measured by the Silicon/Tungsten Luminosity Monitor (LUM), and large angle events (0 {le} |cos{theta}| {le} 0.9655) measured by the Liquid Argon Calorimeter (LAC). Using all of the data in this manner allows for the high-precision measurement of the luminosity provided by the LUM to constrain the uncertainty on {bar g}{sub V}{sup e} and {bar g}{sub A}{sup e}. The measured integrated luminosity for the combined 1993 through 1998 SLD data sample is L{sub Integrated} = 19,247 {+-} 17 (stat.) {+-} 146 (sys.) nb{sup -1}. In contrast with other SLD precision measurements of the effective weak mixing angle, which are sensitive to the ratio {bar g}{sub V}{sup e}/{bar g}{sub A}{sup e}, this result independently determines {bar g}{sub V}{sup 3} and {bar g}{sub A}{sup c}. The analysis techniques to measure {bar g}{sub V}{sup 3} and {bar g}{sub A}{sup c} are described, and the results are compared with other SLD measurements as well as other experiments.

  10. Influence of amplitude-related perfusion parameters in the parotid glands by non-fat-saturated dynamic contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Chiu, Su-Chin; Cheng, Cheng-Chieh; Chang, Hing-Chiu; Chung, Hsiao-Wen; Chiu, Hui-Chu; Liu, Yi-Jui; Hsu, Hsian-He; Juan, Chun-Jung

    2016-01-01

    Purpose: To verify whether quantification of parotid perfusion is affected by fat signals on non-fat-saturated (NFS) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and whether the influence of fat is reduced with fat saturation (FS). Methods: This study consisted of three parts. First, a retrospective study analyzed DCE-MRI data previously acquired on different patients using NFS (n = 18) or FS (n = 18) scans. Second, a phantom study simulated the signal enhancements in the presence of gadolinium contrast agent at six concentrations and three fat contents. Finally, a prospective study recruited nine healthy volunteers to investigate the influence of fat suppression on perfusion quantification on the same subjects. Parotid perfusion parameters were derived from NFS and FS DCE-MRI data using both pharmacokinetic model analysis and semiquantitative parametric analysis. T tests and linear regression analysis were used for statistical analysis with correction for multiple comparisons. Results: NFS scans showed lower amplitude-related parameters, including parameter A, peak enhancement (PE), and slope than FS scans in the patients (all with P < 0.0167). The relative signal enhancement in the phantoms was proportional to the dose of contrast agent and was lower in NFS scans than in FS scans. The volunteer study showed lower parameter A (6.75 ± 2.38 a.u.), PE (42.12% ± 14.87%), and slope (1.43% ± 0.54% s"−"1) in NFS scans as compared to 17.63 ± 8.56 a.u., 104.22% ± 25.15%, and 9.68% ± 1.67% s"−"1, respectively, in FS scans (all with P < 0.005). These amplitude-related parameters were negatively associated with the fat content in NFS scans only (all with P < 0.05). Conclusions: On NFS DCE-MRI, quantification of parotid perfusion is adversely affected by the presence of fat signals for all amplitude-related parameters. The influence could be reduced on FS scans.

  11. Influence of amplitude-related perfusion parameters in the parotid glands by non-fat-saturated dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, Su-Chin [Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 106, Taiwan, Republic of China and Department of Radiology, Tri-Service General Hospital, Taipei 114, Taiwan (China); Cheng, Cheng-Chieh [Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts 02115 (United States); Chang, Hing-Chiu [Department of Diagnostic Radiology, The University of Hong Kong (Hong Kong); Chung, Hsiao-Wen [Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 106, Taiwan (China); Department of Radiology, Tri-Service General Hospital, Taipei 114, Taiwan (China); Department of Radiology, National Defense Medical Center, Taipei 114, Taiwan (China); Chiu, Hui-Chu [Ph.D. Program of Technology Management, Chung Hua University, Hsinchu 300, Taiwan (China); Liu, Yi-Jui [Department of Automatic Control Engineering, Feng-Chia University, Taichung 407, Taiwan (China); Hsu, Hsian-He; Juan, Chun-Jung, E-mail: peterjuancj@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, Taipei 114, Taiwan and Department of Radiology, National Defense Medical Center, Taipei 114, Taiwan (China)

    2016-04-15

    Purpose: To verify whether quantification of parotid perfusion is affected by fat signals on non-fat-saturated (NFS) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and whether the influence of fat is reduced with fat saturation (FS). Methods: This study consisted of three parts. First, a retrospective study analyzed DCE-MRI data previously acquired on different patients using NFS (n = 18) or FS (n = 18) scans. Second, a phantom study simulated the signal enhancements in the presence of gadolinium contrast agent at six concentrations and three fat contents. Finally, a prospective study recruited nine healthy volunteers to investigate the influence of fat suppression on perfusion quantification on the same subjects. Parotid perfusion parameters were derived from NFS and FS DCE-MRI data using both pharmacokinetic model analysis and semiquantitative parametric analysis. T tests and linear regression analysis were used for statistical analysis with correction for multiple comparisons. Results: NFS scans showed lower amplitude-related parameters, including parameter A, peak enhancement (PE), and slope than FS scans in the patients (all with P < 0.0167). The relative signal enhancement in the phantoms was proportional to the dose of contrast agent and was lower in NFS scans than in FS scans. The volunteer study showed lower parameter A (6.75 ± 2.38 a.u.), PE (42.12% ± 14.87%), and slope (1.43% ± 0.54% s{sup −1}) in NFS scans as compared to 17.63 ± 8.56 a.u., 104.22% ± 25.15%, and 9.68% ± 1.67% s{sup −1}, respectively, in FS scans (all with P < 0.005). These amplitude-related parameters were negatively associated with the fat content in NFS scans only (all with P < 0.05). Conclusions: On NFS DCE-MRI, quantification of parotid perfusion is adversely affected by the presence of fat signals for all amplitude-related parameters. The influence could be reduced on FS scans.

  12. An analytical method for estimating the 14N nuclear quadrupole resonance parameters of organic compounds with complex free induction decays for radiation effects studies

    International Nuclear Information System (INIS)

    Iselin, L.H.

    1992-01-01

    The use of 14 N nuclear quadrupole resonance (NQR) as a radiation dosimetry tool has only recently been explored. An analytical method for analyzing 14 N NQR complex free induction decays is presented with the background necessary to conduct pulsed NQR experiments. The 14 N NQR energy levels and possible transitions are derived in step-by-step detail. The components of a pulsed NQR spectrometer are discussed along with the experimental techniques for conducting radiation effects experiments using the spectrometer. Three data analysis techniques -- the power spectral density Fourier transform, state space singular value decomposition (HSVD), and nonlinear curve fitting (using the downhill simplex method of global optimization and the Levenberg-Marquart method) -- are explained. These three techniques are integrated into an analytical method which uses these numerical techniques in this order to determine the physical NQR parameters. Sample data sets of urea and guanidine sulfate data are used to demonstrate how these methods can be employed to analyze both simple and complex free induction decays. By determining baseline values for biologically significant organics, radiation effects on the NQR parameters can be studied to provide a link between current radiation dosimetry techniques and the biological effects of radiation

  13. An analytical method for estimating the 14N nuclear quadrupole resonance parameters of organic compounds with complex free induction decays for radiation effects studies

    Energy Technology Data Exchange (ETDEWEB)

    Iselin, Louis Henry [Univ. of Florida, Gainesville, FL (United States)

    1992-01-01

    The use of 14N nuclear quadrupole resonance (NQR) as a radiation dosimetry tool has only recently been explored. An analytical method for analyzing 14N NQR complex free induction decays is presented with the background necessary to conduct pulsed NQR experiments. The 14N NQR energy levels and possible transitions are derived in step-by-step detail. The components of a pulsed NQR spectrometer are discussed along with the experimental techniques for conducting radiation effects experiments using the spectrometer. Three data analysis techniques -- the power spectral density Fourier transform, state space singular value decomposition (HSVD), and nonlinear curve fitting (using the downhill simplex method of global optimization and the Levenberg-Marquart method) -- are explained. These three techniques are integrated into an analytical method which uses these numerical techniques in this order to determine the physical NQR parameters. Sample data sets of urea and guanidine sulfate data are used to demonstrate how these methods can be employed to analyze both simple and complex free induction decays. By determining baseline values for biologically significant organics, radiation effects on the NQR parameters can be studied to provide a link between current radiation dosimetry techniques and the biological effects of radiation.

  14. Uterus and ovaries in girls and young women with Turner syndrome evaluated by ultrasound and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Cleemann, Line; Holm, Kirsten; Fallentin, Eva

    2011-01-01

    Objective To determine uterine and ovarian size in Turner syndrome (TS) and to compare uterine and ovarian size evaluated by transabdominal ultrasound (US) and magnetic resonance imaging (MRI) in girls with TS and two groups of controls. Design A cross-sectional study. Patients Forty-one girls...

  15. Is there an indication for computed tomography and magnetic resonance imaging in the evaluation of coronary artery bypass grafts?

    NARCIS (Netherlands)

    Dikkers, R.; van der Zaag-Loonen HJ, [No Value; Willems, T.P.; Post, W.J.; Oudkerk, M.

    2009-01-01

    This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive

  16. Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours

    DEFF Research Database (Denmark)

    Kristensen, B.H.; Laursen, F.J.; Logager, V.

    2008-01-01

    Background and purpose: Magnetic resonance (MR) imaging is superior to computed tomography (CT) in radiotherapy of brain tumours. In this study an open low-field MR-simulator is evaluated in order to eliminate the cost of and time spent on additional CT scanning. Materials and methods: Eleven...

  17. Magnetic resonance imaging used for the evaluation of water presence in wood plastic composite boards exposed to exterior conditions

    Science.gov (United States)

    Marek Gnatowski; Rebecca Ibach; Mathew Leung; Grace Sun

    2014-01-01

    Two wood plastic composite (WPC) boards, one experimental and one commercial, were exposed to exterior conditions and evaluated non-destructively using a clinical magnetic resonance imaging (MRI) unit for moisture content (MC) and distribution. The experimental board was exposed in Vancouver, British Columbia, for more than 8 years, and the commercial board was exposed...

  18. Evaluation of Experimental Parameters in the Accelerated Aging of Closed-Cell Foam Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Vanderlan, Michael [ORNL; Atchley, Jerald Allen [ORNL

    2012-12-01

    The thermal conductivity of many closed-cell foam insulation products changes over time as production gases diffuse out of the cell matrix and atmospheric gases diffuse into the cells. Thin slicing has been shown to be an effective means of accelerating this process in such a way as to produce meaningful results. Efforts to produce a more prescriptive version of the ASTM C1303 standard test method led to the ruggedness test described here. This test program included the aging of full size insulation specimens for time periods of five years for direct comparison to the predicted results. Experimental parameters under investigation include: slice thickness, slice origin (at the surface or from the core of the slab), thin slice stack composition, product facings, original product thickness, product density, and product type. The test protocol has been completed and this report provides a detailed evaluation of the impact of the test parameters on the accuracy of the 5-year thermal conductivity prediction.

  19. Evaluation of water quality parameters and associated environmental impact at nuclear power plant sites

    International Nuclear Information System (INIS)

    Joshi, M.L.; Hegde, A.G.

    2005-01-01

    The Nuclear Power Plants use a large quantity of water for the purpose of cooling the turbine condenser. The heated effluents are discharged to aquatic environment by means of once through cooling wherever large water bodies like seacoast or fresh water reservoir are available. The quality of water bodies are important for the growth and biodiversity of aquatic organisms. Several environmental factors like Temperature pH, Dissolved Oxygen have a bearing on the life cycle of aquatic organisms. The paper describes the evaluation of water quality parameters at the two typical sites one on the sea coast (Tarapur) and other at inland site Kaiga and discusses the environmental impact due to discharge to aquatic environment. It is found that the environmental impacts due to both heated effluents and radioactivity are insignificant. The water quality parameters are found to be well within the prescribed standards. (author)

  20. Classification of the coefficients of variation of parameters evaluated in Japanese quail experiments

    Directory of Open Access Journals (Sweden)

    DHV Leal

    2014-06-01

    Full Text Available The objective of this study was to design a classification range of the coefficients of variation (CV of traits used in experiments with eggtype Japanese quails (Coturnix coturnix japonica. The journal Revista Brasileira de Zootecnia was systematically reviewed, using the key word 'quail' during the period of January, 2000 to 2010. The CV of feed intake (g/bird/d, egg production (%/bird/d, egg weight (g, egg mass (g/bird/d, feed conversion ratio per dozen eggs (g/dozen, feed conversion ratio per egg mass (g/g, and egg specific gravity (g/mL were collected. For each parameter, CV were classified using the following median (MD and pseudo-sigma (PS ratio as follows: low (CV MD + 2PS. According to the results, it was concluded that each parameter has a specific classification range that should be taken into account when evaluating experimental precision.