WorldWideScience

Sample records for resonance integral measurements

  1. The Resonance Integral of Gold

    Energy Technology Data Exchange (ETDEWEB)

    Jirlow, K; Johansson, E

    1959-04-15

    The resonance activation integral of gold has been determined, by means of cadmium ratio measurements of thin foils in a neutron beam. Comparison was made with a 1/v detector, and the neutron spectra were measured with a chopper. The resonance integral, RI, is defined as {integral}{sub 0.5}{sup {infinity}}{sigma}{sub r}(E)dE/E, where {sigma}{sub r}(E) is the differenc between the total absorption cross section and the 1/v part. An experimental value of 1490 {+-} 40 barns has been obtained. RI has also been computed from resonance parameter data with the result 1529 {+-} 70 barns.

  2. Measurement of the effect of the lattice pitch on the effective resonance integral of natural uranium

    International Nuclear Information System (INIS)

    Krcevinac, S.; Takac, S.

    1966-04-01

    The present work investigates the dependence of the effective resonance integral on the lattice pitch. Theoretically, the dependence is determined starting from Wigner's rational approximation in which the lattice is characterized by the effective ratio (s/M). Later this allows correlation between the lattice resonance integral and the resonance integral of the single rod (the rod in infinite medium). Using two approximations for Dancoff's factor we give the measured functional dependence of the effective resonance integral on the effective (s/M) ratio. The activation method and the differential technique of measuring absorption distribution in U-238 are used to determine the resonance integral experimentally. Since the effective lattice pitch cannot be defined with certain reliability, due to the use of cadmium in determining the cadmium ratio in the fuel rod, besides other perturbing effects, the method of comparing thermal activations of U-238 and a suitable thermal detector are used to determine the cadmium ratio

  3. Measurement of the effect of the lattice pitch on the effective resonance integral of natural uranium

    Energy Technology Data Exchange (ETDEWEB)

    Krcevinac, S; Takac, S [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1966-04-15

    The present work investigates the dependence of the effective resonance integral on the lattice pitch. Theoretically, the dependence is determined starting from Wigner's rational approximation in which the lattice is characterized by the effective ratio (s/M). Later this allows correlation between the lattice resonance integral and the resonance integral of the single rod (the rod in infinite medium). Using two approximations for Dancoff's factor we give the measured functional dependence of the effective resonance integral on the effective (s/M) ratio. The activation method and the differential technique of measuring absorption distribution in U-238 are used to determine the resonance integral experimentally. Since the effective lattice pitch cannot be defined with certain reliability, due to the use of cadmium in determining the cadmium ratio in the fuel rod, besides other perturbing effects, the method of comparing thermal activations of U-238 and a suitable thermal detector are used to determine the cadmium ratio.

  4. Measurement of the effect of the lattice pitch on the effective resonance integral of natural uranium

    Energy Technology Data Exchange (ETDEWEB)

    Krcevinac, S; Takac, S [Institut za nuklearne nauke ' Boris Kidric' , Vinca, Belgrade (Yugoslavia)

    1966-07-01

    The analytical theory of resonance absorption, as well as the numerical Monte Carlo method, allows calculation of the resonance integral. However, it is based on specific approximations so it may be used accurately enough in a limited number of cases. Likewise, insufficiently accurate know ledge of the basic nuclear constants (e.g. resonance parameters, etc.) used as input data in analytical calculation, leads to inaccurate determination of the resonance integral.. Therefore, experimental determination of the effective resonance integral is still indispensable. In some cases the experimental results are used as the exclusive source of information, or as the basis for the semiempirical technique of calculation, and in others as a check of the new theoretical procedures. There are several experimental methods of direct determination of the resonance integral: the activation method (1,2), the reactor oscillator and the danger coefficient method. Indirectly, using the results of critical experiments, it is possible to determine correlated values of the effective resonance integral. The present work investigates the dependence of the effective resonance integral on the lattice pitch. Theoretically, the dependence is determined starting from Wigner's rational approximation in which the lattice is characterized by the effective ratio (S/M) {sup X}. Later this allows correlation between the lattice resonance integral and the resonance integral of the single rod (the rod in infinite medium). Using two approximations for Dancoff's factor we give the measured functional dependence of the effective resonance integral on the effective (S/M){sup X} ratio. To determine the resonance integral experimentally we used the activation method and the differential technique of measuring absorption distribution in U{sup 2}38. Since, because of the use of cadmium in determining the cadmium ratio in the fuel rod the effective lattice pitch cannot be defined with certain reliability, besides

  5. measurements of the absorption resonance integrals by reactor oscillator method

    International Nuclear Information System (INIS)

    Markovic, V.; Kocic, A.

    1965-12-01

    Experimental values of resonance integrals for silver vary significantly dependent on authors. That is why we have chosen this sample to measure RI. On the other hand, nuclear fuel (for example natural uranium) still represents an interesting objective for research in reactor physics. Measurements of natural uranium are done as a function of S/M. Measurements were done by amplitude reactor oscillator ROB-1/5 with precision from 0.5% - 2% dependent on the conditions of the oscillator. Measurements were completed at the heavy water reactor RB with 2% enriched uranium fuel [fr

  6. Measurement of resonance integral of the 90Sr(n,γ)91Sr reaction

    International Nuclear Information System (INIS)

    Nakamura, Shoji; Furutaka, Kazuyoshi; Wada, Hiroaki; Katoh, Toshio; Harada, Hideo; Fujii, Toshiyuki; Yamana, Hajimu

    2001-01-01

    To obtain fundamental data for research on nuclear transmutation method of radioactive wastes, the resonance integral (I 0 ) of the 90 Sr(n,γ) 91 Sr reaction was measured with an activation method. (author)

  7. The Resonance Integral of Niobium

    Energy Technology Data Exchange (ETDEWEB)

    Hellstrand, E; Lundgren, G

    1962-08-15

    The resonance integral of niobium has been studied by both pile oscillator and activation techniques. A value of 8.15b {+-} 0.65 b was obtained for the infinitely dilute integral. In addition, the variation of the resonance integral with foil thickness has been measured for thicknesses in the range 0.06 mm to 1.36 mm. A separate study of the half-life of the isomeric state in {sup 94}Nb yielded a value T{sub 1/2} = 6.30 - 0.03 m which is about 5 % lower than the value given in literature.

  8. The thermal neutron absorption cross-sections, resonance integrals and resonance parameters of silicon and its stable isotopes

    International Nuclear Information System (INIS)

    Story, J.S.

    1969-09-01

    The data available up to the end of November 1968 on the thermal neutron absorption cross-sections, resonance absorption integrals, and resonance parameters of silicon and its stable isotopes are collected and discussed. Estimates are given of the mean spacing of the energy levels of the compound nuclei near the neutron binding energy. It is concluded that the thermal neutron absorption cross-section and resonance absorption integral of natural silicon are not well established. The data on these two parameters are somewhat correlated, and three different assessments of the resonance integral are presented which differ over-all by a factor of 230. Many resonances have been detected by charged particle reactions which have not yet been observed in neutron cross-section measurements. One of these resonances of Si 2 8, at E n = 4 ± 5 keV might account for the large resonance integral which is derived, very uncertainly, from integral data. The principal source of the measured resonance integral of Si 3 0 has not yet been located. The thermal neutron absorption cross-section of Si 2 8 appears to result mainly from a negative energy resonance, possibly the resonance at E n = - 59 ± 5 keV detected by the Si 2 8 (d,p) reaction. (author)

  9. Measurement and Evaluation of the Activation Resonance Integral of 146Nd, 148Nd and 150Nd

    International Nuclear Information System (INIS)

    Ricabarra, M. D.; Turjanski, R.; Ricabarra, G. H.

    2012-01-01

    Values of the ratio of the reduced activation resonance integral to the thermal cross section, I'/σ 0 of 146 Nd, 148 Nd and 150 Nd were determined relative to gold by measuring cadmium ratios. A lithium-drifted germanium gamma ray spectrometer was used to resolve the activities of the irradiated samples. The results are for 146 Nd I'/σ 0 = 1.42±0.1 0 and with an assumed σ 0 = 1.4 barn, I' = 1 .99±0.20; for 148 Nd I'/ σ 0 = 4.22±0.1 4 and with an assumed σ 0 = 2.5 barn, I' = 10.5±0. 9 barn, and for 150 Nd I'/σ 0 = 13.7±0. 8 and with an assumed σ 0 = 1.2 barn, I' = 16.4±2.8. The resolved and unresolved epithermal integrals of 146 Nd, 148 Nd and 150 Nd were calculated. Values of the spectral correction factor were also calculated, so the resonance integral could be obtained from the epithermal integral data measured in our reactor spectrum in this experiment. Epithermal integral and spectral correction factors are listed in the text. The most important result of this investigation is that the 148 Nd activation reduced resonance integral is about half of the previously recommended value and consequently the radiative width for 148 Nd is also about half of the previously accepted value. (author)

  10. {sup 41}K(n, {gamma}){sup 42}K thermal and resonance integral cross section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.A. Jr.; Maidana, N.L.; Vanin, V.R. [Sao Paulo Univ., SP (Brazil). Lab. do Acelerador Linear; Dias, M.S.; Koskinas, M.F. [IPEN-CNEN, Sao Paulo, SP (Brazil). Lab. de Metrolgia Nuclear; Lopez-Pino, N. [Instituto Superior de Tecnolgias y Ciencias Aplicadas (InSTEC), Habana (Cuba)

    2012-07-01

    We measured the {sup 41}K thermal neutron absorption and resonance integral cross sections after the irradiation of KNO{sub 3} samples near the core of the IEA-R1 IPEN pool-type research reactor. Bare and cadmium-covered targets were irradiated in pairs with Au-Al alloy flux-monitors. The residual activities were measured by gamma-ray spectroscopy with a HPGe detector, with special care to avoid the {sup 42}K decay {beta}{sup -} emission effects on the spectra. The gamma-ray self-absorption was corrected with the help of MCNP simulations. We applied the Westcott formalism in the average neutron flux determination and calculated the depression coefficients for thermal and epithermal neutrons due to the sample thickness with analytical approximations. We obtained 1.57(4) b and 1.02(4) b, for thermal and resonance integral cross sections, respectively, with correlation coefficient equal to 0.39.

  11. Neutron capture measurements and resonance parameters of dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.G.; Kye, Y.U.; Namkung, W.; Cho, M.H. [Pohang University of Science and Technology, Division of Advanced Nuclear Engineering, Pohang, Gyeongbuk (Korea, Republic of); Kang, Y.R.; Lee, M.W. [Dongnam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of); Kim, G.N. [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Ro, T.I. [Dong-A University, Department of Physics, Busan (Korea, Republic of); Danon, Y.; Williams, D. [Rensselaer Polytechnic Institute, Department of Mechanical, Aerospace, and Nuclear Engineering, Troy, NY (United States); Leinweber, G.; Block, R.C.; Barry, D.P.; Rapp, M.J. [Naval Nuclear Laboratory, Knolls Atomic Power Laboratory, Schenectady, NY (United States)

    2017-10-15

    Neutron capture yields of dysprosium isotopes ({sup 161}Dy, {sup 162}Dy, {sup 163}Dy, and {sup 164}Dy) were measured using the time-of-flight method with a 16 segment sodium iodide multiplicity detector. The measurements were made at the 25m flight station at the Gaerttner LINAC Center at Rensselaer Polytechnic Institute. Resonance parameters were obtained using the multilevel R-matrix Bayesian code SAMMY. The neutron capture data for four enriched dysprosium isotopes and one natural dysprosium sample were sequentially fitted. New resonances not listed in ENDF/B-VII.1 were observed. There were 29 and 17 new resonances from {sup 161}Dy and {sup 163}Dy isotopes, respectively. Six resonances from {sup 161}Dy isotope, two resonances from {sup 163}Dy, and four resonances from {sup 164}Dy were not observed. The capture resonance integrals of each isotope were calculated with the resulting resonance parameters and those of ENDF/B-VII.1 in the energy region from 0.5 eV to 20 MeV and were compared to the capture resonance integrals with the resonance parameters from ENDF/B-VII.1. A resonance integral value of the natural dysprosium calculated with present resonance parameters was 1405 ± 3.5 barn. The value is ∝ 0.3% higher than that obtained with the ENDF/B-VII.1 parameters. The distributions of the present and ENDF/B-VII.1 neutron widths were compared to a Porter-Thomas distribution. Neutron strength functions for {sup 161}Dy and {sup 163}Dy were calculated with the present resonance parameters and both values were in between the values of ''Atlas of Neutron Resonances'' and ENDF/B-VII.1. The present radiation width distributions of {sup 161}Dy and {sup 163}Dy were fitted with the χ{sup 2} distribution by varying the degrees of freedom. (orig.)

  12. Measurements of the thermal neutron cross-section and resonance integral for the 108Pd(n,γ)109Pd reaction

    Science.gov (United States)

    Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Do, Nguyen Van; Khue, Pham Duc; Thanh, Kim Tien; Shin, Sung-Gyun; Cho, Moo-Hyun

    2018-06-01

    The thermal neutron capture cross-section (σ0) and resonance integral (I0) of the 108Pd(n,γ)109Pd reaction have been measured relative to that of the monitor reaction 197Au(n,γ)198Au. The measurements were carried out using the neutron activation with the cadmium ratio method. Both the samples and monitors were irradiated with and without cadmium cover of 0.5 mm thickness. The induced activities of the reaction products were measured with a well calibrated HPGe γ-ray detector. In order to improve the accuracy of the results, the necessary corrections for the counting losses were made. The thermal neutron capture cross-section and resonance integral of the 108Pd(n,γ)109Pd reaction were determined to be σ0,Pd = 8.68 ± 0.41 barn and I0,Pd = 245.6 ± 24.8 barn, respectively. The obtained results are compared with literature values and discussed.

  13. Integrated optics ring-resonator chemical sensor with polymer transduction layer

    Science.gov (United States)

    Ksendzov, A.; Homer, M. L.; Manfreda, A. M.

    2004-01-01

    An integrated optics chemical sensor based on a ring resonator with an ethyl cellulose polymer coating has been demonstrated. The measured sensitivity to isopropanol in air is 50 ppm-the level immediately useful for health-related air quality monitoring. The resonator was fabricated using SiO2 and SixNy materials. The signal readout is based on tracking the wavelength of a resonance peak. The resonator layout optimisation for sensing applications is discussed.

  14. An analytical approximation for resonance integral

    International Nuclear Information System (INIS)

    Magalhaes, C.G. de; Martinez, A.S.

    1985-01-01

    It is developed a method which allows to obtain an analytical solution for the resonance integral. The problem formulation is completely theoretical and based in concepts of physics of general character. The analytical expression for integral does not involve any empiric correlation or parameter. Results of approximation are compared with pattern values for each individual resonance and for sum of all resonances. (M.C.K.) [pt

  15. Integral data analysis for resonance parameters determination

    International Nuclear Information System (INIS)

    Larson, N.M.; Leal, L.C.; Derrien, H.

    1997-09-01

    Neutron time-of-flight experiments have long been used to determine resonance parameters. Those resonance parameters have then been used in calculations of integral quantities such as Maxwellian averages or resonance integrals, and results of those calculations in turn have been used as a criterion for acceptability of the resonance analysis. However, the calculations were inadequate because covariances on the parameter values were not included in the calculations. In this report an effort to correct for that deficiency is documented: (1) the R-matrix analysis code SAMMY has been modified to include integral quantities of importance, (2) directly within the resonance parameter analysis, and (3) to determine the best fit to both differential (microscopic) and integral (macroscopic) data simultaneously. This modification was implemented because it is expected to have an impact on the intermediate-energy range that is important for criticality safety applications

  16. Resonance integral of cylindrical absorber; Rezonantni integral cilindricnog absorbera

    Energy Technology Data Exchange (ETDEWEB)

    Slipicevic, K [Elektrotehnicki fakultet, Belgrade (Yugoslavia)

    1968-07-01

    This paper presents the procedure for calculating effective resonance integral for cylindrical rod which enables derivation of improved spatial distribution of source neutron flux. Application of this new expression for penetration factor, simultaneously with Doppler broadening of Breight-Wigner line enabled derivation of new equation for resonance integral which is valid for the whole range of surface-volume ratio of the rod, has correct boundary conditions and gives as special, results same as Wigner and Pomeranchuk. Functions for correcting the effects of interference of potential and resonance dissipation are derived separately.

  17. Measurement of the resonance escape probability

    International Nuclear Information System (INIS)

    Anthony, J.P.; Bacher, P.; Lheureux, L.; Moreau, J.; Schmitt, A.P.

    1957-01-01

    The average cadmium ratio in natural uranium rods has been measured, using equal diameter natural uranium disks. These values correlated with independent measurements of the lattice buckling, enabled us to calculate values of the resonance escape probability for the G1 reactor with one or the other of two definitions. Measurements were performed on 26 mm and 32 mm rods, giving the following values for the resonance escape probability p: 0.8976 ± 0.005 and 0.912 ± 0.006 (d. 26 mm), 0.8627 ± 0.009 and 0.884 ± 0.01 (d. 32 mm). The influence of either definition on the lattice parameters is discussed, leading to values of the effective integral. Similar experiments have been performed with thorium rods. (author) [fr

  18. Indium phosphide-based monolithically integrated PIN waveguide photodiode readout for resonant cantilever sensors

    Energy Technology Data Exchange (ETDEWEB)

    Siwak, N. P. [Department of Electrical and Computer Engineering, Institute for Systems Research, University of Maryland, College Park, Maryland 20742 (United States); Laboratory for the Physical Sciences, 8050 Greenmead Drive, College Park, Maryland 20740 (United States); Fan, X. Z.; Ghodssi, R. [Department of Electrical and Computer Engineering, Institute for Systems Research, University of Maryland, College Park, Maryland 20742 (United States); Kanakaraju, S.; Richardson, C. J. K. [Laboratory for the Physical Sciences, 8050 Greenmead Drive, College Park, Maryland 20740 (United States)

    2014-10-06

    An integrated photodiode displacement readout scheme for a microelectromechanical cantilever waveguide resonator sensing platform is presented. III-V semiconductors are used to enable the monolithic integration of passive waveguides with active optical components. This work builds upon previously demonstrated results by measuring the displacement of cantilever waveguide resonators with on-chip waveguide PIN photodiodes. The on-chip integration of the readout provides an additional 70% improvement in mass sensitivity compared to off-chip photodetector designs due to measurement stability and minimized coupling loss. In addition to increased measurement stability, reduced packaging complexity is achieved due to the simplicity of the readout design. We have fabricated cantilever waveguides with integrated photodetectors and experimentally characterized these cantilever sensors with monolithically integrated PIN photodiodes.

  19. Integrated Optic Surface Plasmon Resonance Measurements in a Borosilicate Glass Substrate

    Directory of Open Access Journals (Sweden)

    Antonino Parisi

    2008-11-01

    Full Text Available The surface plasmon resonance (SPR technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the flow over the sensing region (metal window of different solutions with refractive indexes in the range of interest (1.3÷1.5 for the detection of contaminants in aqueous solutions. After a discussion of the principles of SPR, of the metal window design optimization by means of optical interaction numerical modeling, and of waveguide fabrication techniques, we give a description of system setup and experimental results. Optimum gold film window thickness and width in this guided-wave configuration has been for the first time derived and implemented on an integrated optic prototype device. Its characterization is given by means of the real time waveguide output intensity measurements, which correspond to the interaction between the sensing gold thin film window and the flowing analyte. The SPR curve was subsequently inferred. Finally, a modified version of the device is reported, with channel waveguides arranged in a Y-junction optical circuit, so that laser source stability requirements are lowered by a factor of 85 dB, making possible the use of low cost sources in practical applications.

  20. Iterative resonance self-shielding methods using resonance integral table in heterogeneous transport lattice calculations

    International Nuclear Information System (INIS)

    Hong, Ser Gi; Kim, Kang-Seog

    2011-01-01

    This paper describes the iteration methods using resonance integral tables to estimate the effective resonance cross sections in heterogeneous transport lattice calculations. Basically, these methods have been devised to reduce an effort to convert resonance integral table into subgroup data to be used in the physical subgroup method. Since these methods do not use subgroup data but only use resonance integral tables directly, these methods do not include an error in converting resonance integral into subgroup data. The effective resonance cross sections are estimated iteratively for each resonance nuclide through the heterogeneous fixed source calculations for the whole problem domain to obtain the background cross sections. These methods have been implemented in the transport lattice code KARMA which uses the method of characteristics (MOC) to solve the transport equation. The computational results show that these iteration methods are quite promising in the practical transport lattice calculations.

  1. Measurement of the effective resonance integral of natural uranium; Merenje efektivnog rezonantnog integrala prirodnog urana

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, V; Kocic, A [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1965-12-15

    Good understanding of the nuclear properties of the materials in the reactor core is essential for reactor operation. One of the fundamental properties is the resonance absorption of the fuel, which is directly included in the reactor calculation through resonance escape probability and influences the choice of the materials quality in the core. This paper describes the measurement of resonance absorption integral of the natural uranium as a function of the S/M ratio. Improved experiment planning and analysis of results, as well as improvement of the ROB-1 reactor oscillator device related to the interpretation of results and decrease of reactor drift variations during measurement enabled higher precision of results compared to previous experiments. Poznavanje osobina nuklearnih karakteristika materijala koji ulaze u jezgro nuklearnog reaktora predstavlja bitan faktor u njegovom rezimu rada. Jedna od osnovnih je svakako rezonantna apsorpcija goriva, cija velicina - preko faktora rezonantnog izbegavanja - direktno ulazi u proracun nuklearnih reaktora i utice na izbor kvaliteta materijala koji ga sacinjavaju. U radu se opisuje merenje rezonantnog apsorpcionog integrala prirodnog urana u funkciji odnosa S/M. Bolja postavka eksperimenta i interpretacija rezultata, s jedne strane, i poboljsanje uredjaja reaktorskog oscilatora ROB-1 /1/ u pogledu analize podataka i smanjenja promene drifta reaktora u toku merenja, s druge strane, daju znacaj ovom radu u pogledu dobijanja preciznijih rezultata u odnosu na ranije /2/ (author)

  2. Multilayer Integrated Film Bulk Acoustic Resonators

    CERN Document Server

    Zhang, Yafei

    2013-01-01

    Multilayer Integrated Film Bulk Acoustic Resonators mainly introduces the theory, design, fabrication technology and application of a recently developed new type of device, multilayer integrated film bulk acoustic resonators, at the micro and nano scale involving microelectronic devices, integrated circuits, optical devices, sensors and actuators, acoustic resonators, micro-nano manufacturing, multilayer integration, device theory and design principles, etc. These devices can work at very high frequencies by using the newly developed theory, design, and fabrication technology of nano and micro devices. Readers in fields of IC, electronic devices, sensors, materials, and films etc. will benefit from this book by learning the detailed fundamentals and potential applications of these advanced devices. Prof. Yafei Zhang is the director of the Ministry of Education’s Key Laboratory for Thin Films and Microfabrication Technology, PRC; Dr. Da Chen was a PhD student in Prof. Yafei Zhang’s research group.

  3. The Effective Resonance Integral of Thorium Oxide Rods

    Energy Technology Data Exchange (ETDEWEB)

    Weitman, J

    1962-12-15

    The effective resonance integral of thorium oxide rods has been determined as a function of their surface to mass ratio. The range of S/M values covered is 0.15 - 0.65 cm/g. An experimental technique based on the comparison of activities obtained in thermal and slowing-down neutron fluxes was employed. The shape of the resonance neutron spectrum was determined from measurements with a fast chopper and from calculations, permitting deduction of a correction factor which relates the experimental values to the ideal 1/E case. The results are summarized by the following expression: RI{sub ThO{sub 2}} (5.0 + 15.6{radical}(S/M{sub ThO{sub 2}})) {+-} 5% The main contribution to the margin of error arises from the uncertainties in the 1.5 % spectral correction applied in the 1.5 b '1/v' part deducted and in the 1520 b infinite dilution integral of gold, used as a standard. In order to compare the consistency of Dresner's first equivalence theorem and Nordheim's numerical calculations relative to our results, the resonance integral values for thorium metal rods obtained previously by Hellstrand and Weitman have been recalculated, using recent cross section and spectrum data. The new formula is Rl{sub Th} = (3.3 + 16.1{radical}(S/M{sub Th})) {+-} 5%. It differs from the old one mainly because of the proved non-1/v behaviour of the thorium cross section below the first resonance.

  4. Evaluation of temperature dependent neutron resonance integrals

    International Nuclear Information System (INIS)

    Menon, S.V.G.; Sahni, D.C.

    1975-01-01

    The Fourier transform method is extended for evaluating temperature dependent resonance integrals and Doppler coefficients. With the temperature dependent cross-sections, the slowing-down equation is transformed into a Fredholm integral equation of second kind. A method of solution is presented using the familiar Gauss-Hermite quadrature formulae. As a byproduct of the above technique, a fast and accurate method for computing the resonance integral J-function is given. (orig.) [de

  5. The resonance integral of thorium metal rods

    Energy Technology Data Exchange (ETDEWEB)

    Hellstrand, E; Weitman, J

    1960-03-15

    The resonance integral for thorium metal rods of different diameters has been determined by the activation method. The irradiations took place in the central channel of the reactor R1, where the energy dependence of the neutron flux had earlier been investigated with a fast chopper up to about 1 keV. The absolute calibration was made with gold as a standard. The true resonance integral for gold was taken from the literature as 1,500 {+-} 35 b. The experimental values for thorium were fitted to two alternative expressions with the following results: RI = (1.70 + 15.9{radical}(S/M)) {+-} 5.5%; RI 17.3{radical}(S/M + 0.06) {+-} 5.5 %. The measurements were made for S/M values in the range 0.14 - 0.87 cm{sup 2}/g. The main contribution to the margin of errors arises from the uncertainties in the cross sections used and in the correction for the departure of the neutron energy distribution from the 1/E form.

  6. Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Samarium

    International Nuclear Information System (INIS)

    Leinweber, G.; Burke, J.A.; Knox, H.D.; Drindak, N.J.; Mesh, D.W.; Haines, W.T.; Ballad, R.V.; Block, R.C.; Slovacek, R.E.; Werner, C.J.; Trbovich, M.J.; Barry, D.P.; Sato, T.

    2001-01-01

    The purpose of the present work is to accurately measure the neutron cross sections of samarium. The most significant isotope is 149 Sm, which has a large neutron absorption cross section at thermal energies and is a 235 U fission product with a 1% yield. Its cross sections are thus of concern to reactor neutronics. Neutron capture and transmission measurements were performed by the time-of-flight technique at the Rensselaer Polytechnic institute (RPI) LINAC facility using metallic and liquid Sm samples. The capture measurements were made at the 25 meter flight station with a multiplicity-type capture detector, and the transmission total cross-section measurements were performed at 15- and 25-meter flight stations with 6 Li glass scintillation detectors. Resonance parameters were determined by a combined analysis of six experiments (three capture and three transmission) using the multi-level R-matrix Bayesian code SAMMY version M2. The significant features of this work are as follows. Dilute samples of samarium nitrate in deuterated water (D 2 O) were prepared to measure the strong resonances at 0.1 and 8 eV without saturation. Disk-shaped spectroscopic quartz cells were obtained with parallel inner surfaces to provide a uniform thickness of solution. The diluent feature of the SAMMY program was used to analyze these data. The SAMMY program also includes multiple scattering corrections to capture yield data and resolution functions specific to the RPI facility. Resonance parameters for all stable isotopes of samarium were deduced for all resonances up to 30 eV. Thermal capture cross-section and capture resonance integral calculations were made using the resultant resonance parameters and were compared to results obtained using resonance parameters from ENDF/B-VI updated through release 3. Extending the definition of the capture resonance integral to include the strong 0.1 eV resonance in 149 Sm, present measurements agree within estimated uncertainties with En

  7. Influence of resonance parameters' correlations on the resonance integral uncertainty; 55Mn case

    International Nuclear Information System (INIS)

    Zerovnik, Gasper; Trkov, Andrej; Capote, Roberto; Rochman, Dimitri

    2011-01-01

    For nuclides with a large number of resonances the covariance matrix of resonance parameters can become very large and expensive to process in terms of the computation time. By converting covariance matrix of resonance parameters into covariance matrices of background cross-section in a more or less coarse group structure a considerable amount of computer time and memory can be saved. The question is how important is the information that is discarded in the process. First, the uncertainty of the 55 Mn resonance integral was estimated in narrow resonance approximation for different levels of self-shielding using Bondarenko method by random sampling of resonance parameters according to their covariance matrices from two different 55 Mn evaluations: one from Nuclear Research and Consultancy Group NRG (with large uncertainties but no correlations between resonances), the other from Oak Ridge National Laboratory (with smaller uncertainties but full covariance matrix). We have found out that if all (or at least significant part of the) resonance parameters are correlated, the resonance integral uncertainty greatly depends on the level of self-shielding. Second, it was shown that the commonly used 640-group SAND-II representation cannot describe the increase of the resonance integral uncertainty. A much finer energy mesh for the background covariance matrix would have to be used to take the resonance structure into account explicitly, but then the objective of a more compact data representation is lost.

  8. Vacuum Gap Microstrip Microwave Resonators for 2.5-D Integration in Quantum Computing

    International Nuclear Information System (INIS)

    Lewis, Rupert M.; Henry, Michael David; Schroeder, Katlin

    2017-01-01

    We demonstrate vacuum gap λ/2 microwave resonators as a route toward higher integration in superconducting qubit circuits. The resonators are fabricated from pieces on two silicon chips bonded together with an In-Sb bond. Measurements of the devices yield resonant frequencies in good agreement with simulations. Furthermore, we discuss creating low loss circuits in this geometry.

  9. Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods

    Energy Technology Data Exchange (ETDEWEB)

    Keating, Kristina [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Slater, Lee [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Ntarlagiannis, Dimitris [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Williams, Kenneth H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Earth Sciences Division

    2015-02-24

    This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR) and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements

  10. Fabrication of resonant micro cantilevers with integrated transparent fluidic channel

    DEFF Research Database (Denmark)

    Khan, Faheem; Schmid, Silvan; Davis, Zachary James

    2011-01-01

    Microfabricated cantilevers are proving their potential as excellent tools for analysis applications. In this paper, we describe the design, fabrication and testing of resonant micro cantilevers with integrated transparent fluidic channels. The cantilevers have been devised to measure the density...

  11. A numerical method for resonance integral calculations

    International Nuclear Information System (INIS)

    Tanbay, Tayfun; Ozgener, Bilge

    2013-01-01

    A numerical method has been proposed for resonance integral calculations and a cubic fit based on least squares approximation to compute the optimum Bell factor is given. The numerical method is based on the discretization of the neutron slowing down equation. The scattering integral is approximated by taking into account the location of the upper limit in energy domain. The accuracy of the method has been tested by performing computations of resonance integrals for uranium dioxide isolated rods and comparing the results with empirical values. (orig.)

  12. Determination of space-energy distribution of resonance neutrons in reactor lattice cell and calculation of resonance integrals

    International Nuclear Information System (INIS)

    Zmijarevic, I.

    1980-01-01

    Space-energy distribution of resonance neutrons in reactor lattice cell was determined by solving the Boltzmann equation by spherical harmonics method applying P-3 approximation. Computer code SPLET used for these calculations is described. Resonance absorption and calculation of resonance integrals are described as well. Effective resonance integral values for U-238 resonance at 6.7 Ev are calculated for heavy water reactor cell with metal, oxide and carbide fuel elements

  13. Analysis and measurement of the stability of dual-resonator oscillators

    KAUST Repository

    Ghaed, Hassan

    2012-01-01

    This paper investigates the stability of oscillators with dual-resonating tanks. After deriving oscillator models, it is shown that contrary to prior belief, there can be only one stable oscillating state. Sufficient conditions for stable oscillating states are derived and silicon measurement results are used to prove their validity. A fully integrated transmitter for intraocular pressure sensing that leverages the dual-resonator tank is designed and fabricated based on the derived models. An unstable version of the transmitter is also demonstrated to prove the concept of instability in dual-resonator oscillators © 2012 IEEE.

  14. Low insertion loss SOI microring resonator integrated with nano-taper couplers

    DEFF Research Database (Denmark)

    Pu, Minhao; Frandsen, Lars Hagedorn; Ou, Haiyan

    2009-01-01

    We demonstrate a microring resonator working at TM mode integrated with nano-taper couplers with 3.6dB total insertion loss. The measured insertion loss of the nano-taper coupler was only 1.3dB for TM mode....

  15. Path-integral approach to resonant electron-molecule scattering

    International Nuclear Information System (INIS)

    Winterstetter, M.; Domcke, W.

    1993-01-01

    A path-integral formulation of resonant electron-molecule scattering is developed within the framework of the projection-operator formalism of scattering theory. The formation and decay of resonances is treated in real time as a quantum-mechanical electronic-tunneling process, modified by the coupling of the electronic motion with the nuclear degrees of freedom. It is shown that the electronic continuum can be summed over in the path-integral formulation, resulting formally in the path integral for an effective two-state system with coupling to vibrations. The harmonic-oscillator approximation is adopted for the vibrational motion in the present work. Approximation methods are introduced which render the numerical evaluation of the sum over paths feasible for up to ∼10 3 elementary time slices. The theory is numerically realized for simple but nontrivial models representing the 2 Π g d-wave shape resonance in e - +N 2 collisions and the 2 Σ u + p-wave shape resonance in e - +H 2 collisions, respectively. The accuracy of the path-integral results is assessed by comparison with exact numerical reference data for these models. The essential virtue of the path-integral approach is the fact that the computational effort scales at most linearly with the number of vibrational degrees of freedom. The path-integral method is thus well suited to treat electron collisions with polyatomic molecules and molecular aggregates

  16. The evaluated neutron cross sections and resonance integrals of fission products with Z = 57-62

    International Nuclear Information System (INIS)

    Fedorova, A.F.; Pisanko, Zh.I.; Novoselov, G.M.

    1976-01-01

    Neutron cross sections at a neutron velocity of V=2200 m/s, and resonance integrals for fission products with Z=57-71 are estimated. In obtaining the recommended values the results of the neutron cross sections and resonance integrals for elements used as references were normalized in accordance with the latest adjusted values. In the course of estimation, preference was given to the more accurate methods for obtaining the measured values and to the more recent investigations

  17. The Dependence of the Resonance Integral on the Doppler Effect

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J

    1960-12-15

    The Doppler sensitive contributions to the resonance integral for metal and oxide cylinders have been calculated using tables compiled by Adler, Hinman and Nordheim. The temperatures 20, 200, 350, 500 and 650 deg C have been investigated for the pure metal and 20, 300, 600, 900 and 1200 deg C for the oxide. Contributions from the separate resonances in the resolved region and for certain energies in the unresolved region are accounted for in detail. Integration over adequate statistical distributions has been carried out for the resonance parameters in the unresolved region. The increase in the resonance integral at elevated temperatures due to the Doppler effect is given separately in tables and diagrams.

  18. Integrated polymer micro-ring resonators for optical sensing applications

    OpenAIRE

    Girault , Pauline; Lorrain , Nathalie; Poffo , Luiz; Guendouz , Mohammed; Lemaitre , Jonathan; Carré , Christiane; Gadonna , Michel; Bosc , Dominique; Vignaud , Guillaume

    2015-01-01

    International audience; Micro-resonators (MR) have become a key element for integrated optical sensors due to their integration capability and their easy fabrication with low cost polymer materials. Nowadays, there is a growing need on MRs as highly sensitive and selective functions especially in the areas of food and health. The context of this work is to implement and study integrated micro-ring resonators devoted to sensing applications. They are fabricated by processing SU8 polymer as cor...

  19. Resonance integral analytical calculation considering shadowing effect

    International Nuclear Information System (INIS)

    Monteiro, M.A.M.; Martinez, A.S.

    1990-01-01

    It is presented a method for the Resonance Integral Calculation in the fuel and moderator regions, including the shadowing effect. This effect appears due to the presence of several fuel rods in a infinite moderator region. The method is based on the approximations to the J (ξ, β) function and theirs partial derivatives in relation to β. The dependence of the Resonance Integral in the J (ξ, β) comes from the rational approximation to the neutron escape probability. The final results were obtained in a very simple and fast way, and they show the good accuracy of the method. (author)

  20. The evaluated neutron cross sections and resonance integrals of fission products with Z=63-71

    International Nuclear Information System (INIS)

    Fedorova, A.F.; Pisanko, Zh.I.; Novoselov, G.M.

    1976-01-01

    Neutron cross sections at a neutron velocity of V=2200 m/s, and the resonance integrals for fission products with Z=63-71 are estimated. In obtaining the recommended values the results were normalized of the neutron cross sections and resonance integrals for elements used as references in accordance with the latest adjusted values. In the course of estimation, preference was given to the more accurate measuring methods and the more recent investigations. Scientific publications up to 1975 have been used

  1. Thermal neutron capture cross-section and resonance integral measurements of {sup 139}La(n, γ){sup 140}La and {sup 140}Ce(n, γ){sup 141}Ce using a Am-Be neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Panikkath, Priyada; Mohanakrishnan, P. [Manipal University, Manipal Centre for Natural Sciences, Karnataka (India)

    2017-03-15

    Thermal neutron capture cross-sections and resonance integrals of {sup 139}La(n, γ){sup 140}La and {sup 140}Ce (n, γ){sup 141}Ce are measured with respect to reference reactions {sup 197}Au(n, γ){sup 198}Au and {sup 55}Mn(n, γ){sup 56}Mn using the neutron activation technique. Measurements are carried out using neutrons from an Am-Be source located inside a concrete bunker. Two different methods are used for determining self-shielding factors of activation foils as well as for finding the epithermal neutron spectrum shape factor. For {sup 139}La with reference to {sup 197}Au and {sup 55}Mn the measured thermal cross sections are 9.24 ± 0.25 b and 9.28 ± 0.37 b, respectively, while the measured resonance integrals are 12.18 ± 0.67 b and 11.81 ± 0.94 b, respectively. For {sup 140}Ce with reference to {sup 197}Au and {sup 55}Mn the measured thermal cross sections are 0.44 ± 0.01 b and 0.44 ± 0.02 b, respectively, while the measured resonance integrals are 0.55 ± 0.03 b and 0.54 ± 0.04 b, respectively. The present measurements are compared with earlier measurements and evaluations. Presently estimated values confirm the established {sup 139}La(n, γ){sup 140}La cross-sections. The presently measured thermal capture cross-section {sup 140}Ce(n, γ){sup 141}Ce, though lower than the evaluated data, is having higher accuracy compared to previous measurements with large uncertainties. The resonance integral measured is higher (like most previous measurements) than most evaluations requiring a revision of the evaluated data. (orig.)

  2. ZUT, Resonance Integrals in Resolved Region at Various Temperature, Escape Probability Calculation

    International Nuclear Information System (INIS)

    Kuncir, G.F.

    1984-01-01

    1 - Nature of physical problem solved: ZUT computes resonance integrals from resonance parameters for a wide variety of temperatures, compositions, and geometries for the resolved resonances. 2 - Method of solution: The form used permits specification of escape probability as a function of the lump dimension and the mean free path. The absorber term may be treated by the integral method, the narrow resonance or the infinite mass approximation. Moderator terms may be represented either by the full integral method (IM) or the asymptotic (NR) form

  3. Significantly improving nuclear resonance fluorescence non-destructive assay by using the integral resonance transmission method and photofission

    International Nuclear Information System (INIS)

    Angell, Christopher T.; Hayakawa, Takehito; Shizuma, Toshiyuki; Hajima, Ryoichi

    2013-01-01

    Non-destructive assay (NDA) of 239 Pu in spent nuclear fuel or melted fuel using a γ-ray beam is possible using self absorption and the integral resonance transmission method. The method uses nuclear resonance absorption where resonances in 239 Pu remove photons from the beam, and the selective absorption is detected by measuring the decrease in scattering in a witness target placed in the beam after the fuel, consisting of the isotope of interest, namely 239 Pu. The method is isotope specific, and can use photofission or scattered γ-rays to assay the 239 Pu. It overcomes several problems related to NDA of melted fuel, including the radioactivity of the fuel, and the unknown composition and geometry. This talk will explain the general method, and how photofission can be used to assay specific isotopes, and present example calculations. (author)

  4. Measurement of magnetization of Ga1−xMnxAs by ferromagnetic resonance

    International Nuclear Information System (INIS)

    Hagmann, J.A.; Traudt, K.; Zhou, Y.Y.; Liu, X.; Dobrowolska, M.; Furdyna, J.K.

    2014-01-01

    In this paper, we extend ferromagnetic resonance (FMR) studies of thin layers of the ferromagnetic semiconductor Ga 1−x Mn x As to the analysis of the integrated intensity of the resonance in order to obtain information on the total spin in the sample directly involved in ferromagnetically-ordered magnetization. A theoretical model is proposed for the dependences of the FMR integrated intensity and linewidth on the orientation of the applied magnetic field as the field direction is varied from in-plane to normal-to-the-plane of the Ga 1−x Mn x As layer. The strain-induced magnetic anisotropy of Ga 1−x Mn x As presents a significant challenge to conventional FMR linewidth and integrated intensity models. The new model predicts that the integrated FMR intensity is proportional to the saturation magnetization M S of the sample, with the constant of proportionality varying as a function of the polar and azimuthal angles of the applied magnetic field. The angular and temperature behaviors of the integrated intensity and linewidth of the FMR predicted by the proposed model are in good qualitative agreement with measurements. - Highlights: • We extend ferromagnetic resonance to the analysis of total magnetization of thin film Ga 1−x Mn x As. • We formulate a theoretical model for FMR integrated intensity and linewidth. • The model predicts that integrated FMR intensity is proportional to magnetization. • Predictions made by the model are in good qualitative agreement with measurements

  5. Thermal neutron capture and resonance integral cross sections of {sup 45}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Thi Hien, Nguyen [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Guinyun, E-mail: gnkim@knu.ac.kr [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Kwangsoo [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Shin, Sung-Gyun; Cho, Moo-Hyun [Department of Advanced Nuclear Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Lee, Manwoo [Research Center, Dongnam Institute of Radiological and Medical Science, Busan 619-953 (Korea, Republic of)

    2015-11-01

    The thermal neutron cross section (σ{sub 0}) and resonance integral (I{sub 0}) of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been measured relative to that of the {sup 197}Au(n,γ){sup 198}Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (G{sub th}) and resonance (G{sub epi}) neutron self-shielding, the γ-ray attenuation (F{sub g}) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been determined relative to the reference values of the {sup 197}Au(n,γ){sup 198}Au reaction, with σ{sub o,Au} = 98.65 ± 0.09 barn and I{sub o,Au} = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σ{sub o,Sc} = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be I{sub o,Sc} = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  6. A Unilateral Nuclear Magnetic Resonance Sensor for Nondestructive Wood Moisture Measurements

    Directory of Open Access Journals (Sweden)

    YU Deng-jie

    2017-12-01

    Full Text Available An unilateral nuclear magnetic resonance (UMR sensor was designed to measure wood moisture nondestructively. The sensor consisted of a unilateral magnet, an anti-eddy current module, a radiofrequency (RF coil and an impedance matching and tuning circuit. The sensor produced a static magnetic field of 71.1 mT (resonant frequency:3.027 MHz in a 50 mm×50 mm plane locating 75 mm above the sensor's surface. Preliminary nondestructive measurement of wood moisture was carried out with the sensor. The moisture distribution in the radical direction of a cylindrical wood sample was scanned. Variations in transverse relaxation time (T2 from the bark to core were obtained. Evaporation of moisture during wood drying was also measured with the UMR sensor. Experimental results showed that:the peak of long T2 component in the T2 spectrum moved to left and the peak integral area decreased gradually during drying. The integral area was proportional to the moisture content of the sample. The work presents a portable UMR device for wood research which may potentially be used for nondestructive moisture measurement on living trees in situ.

  7. New methodology for analytical calculation of resonance integrals in an heterogeneous medium

    International Nuclear Information System (INIS)

    Campos, T.P.R. de; Martinez, A.S.

    1986-01-01

    A new methodology for analytical calculation of Resonance Integral in a typical fuel cell is presented. The expression obtained for the Resonance Integral presents the advantage of being analytical. Its constituent terms are combinations of the well known function J(xi,β) with its partial derivatives in regard to β. This is a general expression for all types of resonance. The parameters used in this method depend on the resonance type and are obtained as a function of the parameter lambda. A simple expression, depending on resonance parameters is proposed for this variable. (Author) [pt

  8. "Cul-de-sac" microstrip resonators for high-speed integrated optical commutator switches

    Science.gov (United States)

    Jaeger, Nicolas A.; Chen, Mingche

    1993-04-01

    A novel microstrip resonator structure for use with integrated Y-branch optical modulators fabricated in Ti:LiNbO3 is proposed. The legs of the structure are intended to act as the electrodes of the modulator, with light being directed into each of the output waveguides of the Y-branch on alternate half-cycles of the standing wave excited in the resonator; forming an optical commutator switch. Such resonators having Al2O3 substrates were designed, fabricated, and tested. Measurements on one such resonator, operating at 7.12 GHz and having an unloaded quality factor of 123, indicating that 50 V should develop across the ends of its legs for 35 mW dissipated power; the corresponding values, from the model used to design the resonator, were 179, 50 V,and 24 mW, respectively. Using the model it is shown that a similar resonator fabricated on LiNbO3 should be able to develop about 50 V for 100 mW dissipated power at 15 GHz.

  9. Integrated MEMS/NEMS Resonant Cantilevers for Ultrasensitive Biological Detection

    Directory of Open Access Journals (Sweden)

    Xinxin Li

    2009-01-01

    Full Text Available The paper reviews the recent researches implemented in Chinese Academy of Sciences, with achievements on integrated resonant microcantilever sensors. In the resonant cantilevers, the self-sensing elements and resonance exciting elements are both top-down integrated with silicon micromachining techniques. Quite a lot of effort is focused on optimization of the resonance mode and sensing structure for improvement of sensitivity. On the other hand, to enable the micro-cantilevers specifically sensitive to bio/chemical molecules, sensing materials are developed and modified on the cantilever surface with a self-assembled monolayer (SAM based bottom-up construction and surface functionalization. To improve the selectivity of the sensors and depress environmental noise, multiple and localized surface modifications are developed. The achieved volume production capability and satisfactory detecting resolution to trace-level biological antigen of alpha-fetoprotein (AFP give the micro-cantilever sensors a great promise for rapid and high-resoluble detection.

  10. Measurement of global and local resonance terms

    CERN Document Server

    Tomás, R; Calaga, R; Fischer, W; Franchi, A; Rumolo, Giovanni

    2005-01-01

    Recently, resonance driving terms were successfully measured in the CERN SPS and the BNL RHIC from the Fourier spectrum of beam position monitor (BPM) data. Based on these measurements a new analysis has been derived to extract truly local observables from BPM data. These local observables are called local resonance terms since they share some similarities with the global resonance terms. In this paper we derive these local terms analytically and present experimental measurements of sextupolar global and local resonance terms in RHIC. Nondestructive measurements of these terms using ac dipoles are also presented.

  11. A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators

    Directory of Open Access Journals (Sweden)

    Faisal Iqbal

    2018-04-01

    Full Text Available Microelectromechanical systems (MEMS resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA was performed using the analysis of variance (ANOVA method. The results demonstrate that the resonant frequency ( f r is mostly affected by systematic error. However, the quality (Q factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force.

  12. The temperature coefficient of the resonance integral for uranium metal and oxide

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, P; Hellstrand, E; Homer, S

    1960-06-15

    The temperature coefficient of the resonance integral in uranium metal and oxide has been measured over a wide temperature range for rods with three different diameters. The results for metal agree with most earlier results from activation measurements but differ as much as a factor of two from results obtained with reactivity methods. For oxide only one measurement has been reported recently. Our value is considerably lower than the result of that measurement. The experiments will continue in order to find the reason for the large discrepancy mentioned above.

  13. The temperature coefficient of the resonance integral for uranium metal and oxide

    International Nuclear Information System (INIS)

    Blomberg, P.; Hellstrand, E.; Homer, S.

    1960-06-01

    The temperature coefficient of the resonance integral in uranium metal and oxide has been measured over a wide temperature range for rods with three different diameters. The results for metal agree with most earlier results from activation measurements but differ as much as a factor of two from results obtained with reactivity methods. For oxide only one measurement has been reported recently. Our value is considerably lower than the result of that measurement. The experiments will continue in order to find the reason for the large discrepancy mentioned above

  14. Resonance integral calculations for high temperature reactors

    International Nuclear Information System (INIS)

    Blake, J.P.H.

    1960-02-01

    Methods of calculation of resonance integrals of finite dilution and temperature are given for both, homogeneous and heterogeneous geometries, together with results obtained from these methods as applied to the design of high temperature reactors. (author)

  15. Control of integrated micro-resonator wavelength via balanced homodyne locking.

    Science.gov (United States)

    Cox, Jonathan A; Lentine, Anthony L; Trotter, Douglas C; Starbuck, Andrew L

    2014-05-05

    We describe and experimentally demonstrate a method for active control of resonant modulators and filters in an integrated photonics platform. Variations in resonance frequency due to manufacturing processes and thermal fluctuations are corrected by way of balanced homodyne locking. The method is compact, insensitive to intensity fluctuations, minimally disturbs the micro-resonator, and does not require an arbitrary reference to lock. We demonstrate long-term stable locking of an integrated filter to a laser swept over 1.25 THz. In addition, we show locking of a modulator with low bit error rate while the chip temperature is varied from 5 to 60° C.

  16. Multilevel effect in uranium-238 and thorium-232 effective neutron capture resonance integrals

    International Nuclear Information System (INIS)

    Tellier, H.

    1981-01-01

    Until now, there has been a discrepancy between the computed and the measured values of the /sup 238/U effective capture integral. Recently, several new measurements of the resonance parameters were carried out and the use of a multilevel formalism was suggested to compute the /sup 238/U cross sections. This paper shows that the simultaneous use of recent parameters and the Reich-Moore formalism explain the discrepancy. 31 refs

  17. Measurement of thermal neutron cross-section and resonance integral for the 165Ho(n,γ) 166gHo reaction using electron linac-based neutron source

    Science.gov (United States)

    Nguyen, Van Do; Pham, Duc Khue; Kim, Tien Thanh; Kim, Guinyun; Lee, Manwoo; Kim, Kyung Sook; Kang, Heung-Sik; Cho, Moo-Hyun; Ko, In Soo; Namkung, Won

    2011-01-01

    The thermal neutron cross-section and the resonance integral of the 165Ho(n,γ) 166gHo reaction have been measured by the activation method using a 197Au(n,γ) 198Au monitor reaction as a single comparator. The high-purity natural Ho and Au foils with and without a cadmium shield case of 0.5 mm thickness were irradiated in a neutron field of the Pohang neutron facility. The induced activities in the activated foils were measured with a calibrated p-type high-purity Ge detector. The correction factors for the γ-ray attenuation ( Fg), the thermal neutron self-shielding ( Gth), the resonance neutron self-shielding ( Gepi) effects, and the epithermal neutron spectrum shape factor ( α) were taken into account. The thermal neutron cross-section for the 165Ho(n,γ) 166gHo reaction has been determined to be 59.7 ± 2.5 barn, relative to the reference value of 98.65 ± 0.09 barn for the 197Au(n,γ) 198Au reaction. By assuming the cadmium cut-off energy of 0.55 eV, the resonance integral for the 165Ho(n,γ) 166gHo reaction is 671 ± 47 barn, which is determined relative to the reference value of 1550 ± 28 barn for the 197Au(n,γ) 198Au reaction. The present results are, in general, good agreement with most of the previously reported data within uncertainty limits.

  18. Neutron Transmission and Capture Measurements and Resonance Parameter Analysis of Neodymium from 1eV to 500 eV

    International Nuclear Information System (INIS)

    DP Barry; MJ Trbovich; Y Danon; RC Block; RE Slovacek

    2005-01-01

    Neodymium is a 235 U fission product and is important for reactor neutronic calculations. The aim of the present work is to improve upon the existing neutron cross section data of neodymium. Neutron capture and transmission measurements were performed by the time-off-light technique at the Rensselaer Polytechnic Institute LINAC laboratory using metallic neodymium samples. The capture measurements were made at the 25-m flight station with a 16-segment NaI multiplicity detector, and the transmission measurements were performed at 15-m and 25-m flight stations, respectively, with 6 Li glass scintillation detectors. After the data were collected and reduced, resonance parameters were determined by combined fitting of the transmission and capture data with the multilevel R-matrix Bayesian code SAMMY. The resonance parameters for all naturally occurring neodymium isotopes were deduced within the energy range of 1 eV to 500 eV. The resulting resonance parameters were used to calculate the capture resonance integrals from this energy. The RPI parameters gave a resonance integral value of 32 ± 1 barns that is approximately 7% lower than that obtained with the ENDF-B/VI parameters. The current measurements significantly reduce the uncertainties on the resonance parameters when compared with previously published parameters

  19. The effect of non-uniform fuel rod temperatures on effective resonance integrals

    International Nuclear Information System (INIS)

    Reichel, A.

    1961-06-01

    The effective resonance integral for heterogeneous lattices can be reduced to the effective resonance integral for an equivalent homogeneous system with a fairly well defined error depending on lump size and geometry. This report investigates the effect of a radial parabolic temperature variation in cylindrical lumps on the equivalent homogeneous effective resonance integral. Also determined is the equivalent uniform temperature to be taken in the usual formulae to allow for non-uniform fuel rod temperature. This effective temperature is found to be T eff. = T s + 4/9 (T c - T s ) where T s and T c are the surface and central temperatures of the lump. (author)

  20. Effect of resonance line shape on precision measurements of nuclear magnetic resonance shifts

    International Nuclear Information System (INIS)

    Kachurin, A.M.; Smelyanskij, A.Ya.

    1986-01-01

    Effect of resonance line shape on the systematic error of precision measurements of nuclear magnetic resonance (NMR) shifts of high resolution (on the center of NMR dispersion line) is analysed. Effect of the device resonance line form-function asymmetry is evaluated; the form-function is determined by configuration of the spectrometer magnetic field and enters the convolution, which describes the resonance line form. It is shown that with the increase of the relaxation line width the form-function effect on the measurement error yields to zero. The form-function effect on measurements and correction of a phase angle of NMR detection is evaluated. The method of semiquantitative evaluation of resonance line and NMR spectrometer parameters, guaranteeing the systematic error of the given infinitesimal, is presented

  1. A Series-Fed Linear Substrate-Integrated Dielectric Resonator Antenna Array for Millimeter-Wave Applications

    Directory of Open Access Journals (Sweden)

    Ke Gong

    2018-01-01

    Full Text Available A series-fed linear substrate-integrated dielectric resonator antenna array (SIDRAA is presented for millimeter-wave applications, in which the substrate-integrated dielectric resonator antenna (SIDRA elements and the feeding structure can be codesigned and fabricated using the same planar process. A prototype 4 × 1 SIDRAA is designed at Ka-band and fabricated with a two-layer printed circuit board (PCB technology. Four SIDRAs are implemented in the Rogers RT6010 substrate using the perforation technique and fed by a compact substrate-integrated waveguide (SIW through four longitudinal coupling slots within the Rogers RT5880 substrate. The return loss, radiation patterns, and antenna gain were experimentally studied, and good agreement between the measured and simulated results is observed. The SIDRAA example provides a bandwidth of about 10% around 34.5 GHz for 10 dB return loss and stable broadside radiation patterns with the peak gain of 10.5–11.5 dBi across the band.

  2. Electronically Tunable Fully Integrated Fractional-Order Resonator

    KAUST Repository

    Tsirimokou, Georgia

    2017-03-20

    A fully integrated implementation of a parallel fractional-order resonator which employs together a fractional order capacitor and a fractional-order inductor is proposed in this paper. The design utilizes current-controlled Operational Transconductance Amplifiers as building blocks, designed and fabricated in AMS 0:35m CMOS process, and based on a second-order approximation of a fractional-order differentiator/ integrator magnitude optimized in the range 10Hz–700Hz. An attractive benefit of the proposed scheme is its electronic tuning capability.

  3. Electronically Tunable Fully Integrated Fractional-Order Resonator

    KAUST Repository

    Tsirimokou, Georgia; Psychalinos, Costas; Elwakil, Ahmed S.; Salama, Khaled N.

    2017-01-01

    A fully integrated implementation of a parallel fractional-order resonator which employs together a fractional order capacitor and a fractional-order inductor is proposed in this paper. The design utilizes current-controlled Operational Transconductance Amplifiers as building blocks, designed and fabricated in AMS 0:35m CMOS process, and based on a second-order approximation of a fractional-order differentiator/ integrator magnitude optimized in the range 10Hz–700Hz. An attractive benefit of the proposed scheme is its electronic tuning capability.

  4. TUZ, Resonance Integrals in Unresolved Region, Various Temperature, From Porter-Thomas Distribution

    International Nuclear Information System (INIS)

    Kuncir, G.F.

    1969-01-01

    1 - Nature of physical problem solved: TUZ computes resonance integrals for a wide variety of temperatures, compositions, and geometries for the unresolved resonances. 2 - Method of solution: The resonances are considered to be defined by an average over the Porter-Thomas distribution of neutron widths

  5. Design of a Miniaturized X-Band Diplexer Based on Novel One-Third-Mode Substrate Integrated Resonator Filters

    Science.gov (United States)

    Zhang, Hao; Kang, Wei; Wu, Wen

    2017-12-01

    In this paper, a miniaturized diplexer designed with two novel one-third-mode substrate integrated resonator (OTMSIR) filters has been presented. The one-third triangular resonator cavity with two transmission zeros (TZs) and two transmission poles is investigated. TZs are implemented by taking cross couplings of lower order modes in this design. The diplexer is then obtained by integrating two different sizes of OTMSIR filters with a common T-junction structure. A X-band diplexer operating at 10 GHz and 11.5 GHz is designed on a substrate with a dielectric constant of 3.55 to verify the above design concept. This novel structure features more compact size, better transmission performance, higher out of band rejection and easier integration compared with other circuits. A good agreement is obtained between the simulations and the measured results.

  6. Proportional-Integral-Resonant AC Current Controller

    Directory of Open Access Journals (Sweden)

    STOJIC, D.

    2017-02-01

    Full Text Available In this paper an improved stationary-frame AC current controller based on the proportional-integral-resonant control action (PIR is proposed. Namely, the novel two-parameter PIR controller is applied in the stationary-frame AC current control, accompanied by the corresponding parameter-tuning procedure. In this way, the proportional-resonant (PR controller, common in the stationary-frame AC current control, is extended by the integral (I action in order to enable the AC current DC component tracking, and, also, to enable the DC disturbance compensation, caused by the voltage source inverter (VSI nonidealities and by nonlinear loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, which corresponds to a wide range of AC power converter applications, such as AC motor drives, uninterruptible power supplies, and active filters. While the PIR controllers commonly have three parameters, the novel controller has two. Also, the provided parameter-tuning procedure needs only one parameter to be tuned in relation to the load and power converter model parameters, since the second controller parameter is directly derived from the required controller bandwidth value. The dynamic performance of the proposed controller is verified by means of simulation and experimental runs.

  7. Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancement

    International Nuclear Information System (INIS)

    Yu Haitao; Li Xinxin; Gan Xiaohua; Liu Yongjing; Liu Xiang; Xu Pengcheng; Li Jungang; Liu Min

    2009-01-01

    With an integrated resonance exciting heater and a self-sensing piezoresistor, resonant micro-cantilever bio/chemical sensors are optimally designed and fabricated by micromachining techniques. This study is emphasized on the optimization of the integrated heating resistor. Previous research has put the heater at either the cantilever clamp end, the midpoint or the free end. Aiming at sufficiently high and stable resonant amplitude, our research indicates that the optimized location of the thermal-electric exciting resistor is the clamp end instead of other positions. By both theoretical analysis and resonance experiments where three heating resistors are placed at the three locations of the fabricated cantilever, it is clarified that the clamp end heating provides the most efficient resonance excitation in terms of resonant amplitude, Q-factor and resonance stability. Besides, the optimized combination of dc bias and ac voltage is determined by both analysis and experimental verification. With the optimized heating excitation, the resonant cantilever is used for biotin–avidin-specific detection, resulting in a ±0.1 Hz ultra-low noise floor of the frequency signal and a 130 fg mass resolution. In addition to resonance excitation, the heater is used to heat up the cantilever for speed-up desorption after detection that helps rapid and repeated sensing to chemical vapor. The clamp end is determined (by simulation) as the optimal heating location for uniform temperature distribution on the cantilever. Using the resonant cantilever, a rapid and repeated sensing experiment on dimethyl methylphosphonate (DMMP) vapor shows that a short-period heating at the detection interval significantly quickens the signal recovery and enhances the sensing repeatability

  8. Investigations of a voltage-biased microwave cavity for quantum measurements of nanomechanical resonators

    Science.gov (United States)

    Rouxinol, Francisco; Hao, Hugo; Lahaye, Matt

    2015-03-01

    Quantum electromechanical systems incorporating superconducting qubits have received extensive interest in recent years due to their promising prospects for studying fundamental topics of quantum mechanics such as quantum measurement, entanglement and decoherence in new macroscopic limits, also for their potential as elements in technological applications in quantum information network and weak force detector, to name a few. In this presentation we will discuss ours efforts toward to devise an electromechanical circuit to strongly couple a nanomechanical resonator to a superconductor qubit, where a high voltage dc-bias is required, to study quantum behavior of a mechanical resonator. Preliminary results of our latest generation of devices integrating a superconductor qubit into a high-Q voltage biased microwave cavities are presented. Developments in the circuit design to couple a mechanical resonator to a qubit in the high-Q voltage bias CPW cavity is discussed as well prospects of achieving single-phonon measurement resolution. National Science Foundation under Grant No. DMR-1056423 and Grant No. DMR-1312421.

  9. Measurements of the Z boson resonance parameters at SLC [SLAC Linear Collider

    International Nuclear Information System (INIS)

    Hearty, C.

    1989-07-01

    This paper presents the measurement by the Mark II experiment at the SLAC Linear Collider of the parameters of the Z boson resonance. The results are updated from those presented at the SLAC Summer Institute to include all data presented in the most recent Mark II publication, consisting of 19 nb -1 of data at ten different center-of-mass energies between 89.2 and 93.0 GeV. The resonance parameters are extracted by measuring the Z production cross section at a series of center-of-mass energies (scan points) near the Z peak, then fitting these data with the theoretical cross section. The four major aspects of the analysis are the determination at each scan point of the center-of-mass energy (E), the integrated luminosity, the number of Z decays and the expected cross section as a function of the resonance parameters, such as mass and width. I will discuss each of these steps in turn, after a brief description of the Mark II detector, then conclude with the results of the analysis. 7 refs., 9 figs., 3 tabs

  10. A Methodology to Integrate Magnetic Resonance and Acoustic Measurements for Reservoir Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Parra, Jorge O.; Hackert, Chris L.; Collier, Hughbert A.; Bennett, Michael

    2002-01-29

    The objective of this project was to develop an advanced imaging method, including pore scale imaging, to integrate NMR techniques and acoustic measurements to improve predictability of the pay zone in hydrocarbon reservoirs. This is accomplished by extracting the fluid property parameters using NMR laboratory measurements and the elastic parameters of the rock matrix from acoustic measurements to create poroelastic models of different parts of the reservoir. Laboratory measurement techniques and core imaging are being linked with a balanced petrographical analysis of the core and theoretical model.

  11. Photonic crystal resonator integrated in a microfluidic system

    DEFF Research Database (Denmark)

    Rodrigues de Sousa Nunes, Pedro André; Mortensen, Niels Asger; Kutter, Jörg Peter

    2008-01-01

    We report on a novel optofluidic system consisting of a silica-based 1D photonic crystal, integrated planar waveguides, and electrically insulated fluidic channels. An array of pillars in a microfluidic channel designed for electrochromatography is used as a resonator for on-column label...

  12. Hadronic resonance production measured with the ALICE detector

    CERN Document Server

    Dash, Ajay

    2015-01-01

    Hadronic resonances serve as a unique tool to study the properties of hot and dense matter pro- duced in heavy-ion collisions. These properties can be studied by measuring the ratios of hadronic resonance yields to the yields of longer-lived hadrons which can be used to investigate the re- scattering effects and the chemical freeze-out temperature. Resonance measurements in pp and p–Pb collisions provide a necessary baseline for heavy-ion data and help to disentangle the initial- state effects from medium-induced effects. The ALICE Collaboration has measured resonances such as, K ∗ (892) 0 and φ (1020) in pp, p–Pb, and Pb–Pb collisions at the LHC energies. These resonances are reconstructed via their hadronic decay channel in a wide momentum range at midrapidity. In this work, we present recent results on the transverse momentum spectra, mean transverse momentum, ratios of resonance production relative to that of long-lived hadrons.

  13. Measurement of thermal neutron cross section and resonance integral of the reaction {sup 135}Cs(n,{gamma}){sup 136}Cs

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Toshio; Nakamura, Shoji; Harada, Hideo [Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan); Hatsukawa, Yuichi; Shinohara, Nobuo; Hata, Kentaro; Kobayashi, Katsutoshi; Motoishi, Shoji; Tanase, Masakazu

    1997-03-01

    The thermal neutron(2,200 m/s neutron) capture cross section({sigma}{sub 0}) and the resonance integral(I{sub 0}) of the reaction {sup 135}Cs(n,{gamma}){sup 136}Cs were measured by an activation method. Targets of radioactive cesium, which include {sup 135}Cs, {sup 137}Cs and stable {sup 133}Cs, were irradiated with reactor neutrons within or without a Cd shield case. The ratio of the number of nuclei of {sup 135}Cs to that of {sup 137}Cs was measured with a quadrupole mass spectrometer. This ratio and the ratio of activity of {sup 136}Cs to that of {sup 137}Cs were used for deduction of the {sigma}{sub 0} and the I{sub 0} of {sup 135}Cs. The {sigma}{sub 0} and the I{sub 0} of the reaction {sup 135}Cs(n,{sigma}){sup 136}Cs were 8.3 {+-} 0.3 barn and 38.1 {+-} 2.6 barn, respectively. (author)

  14. An attempt to explain the uranium 238 resonance integral discrepancy

    International Nuclear Information System (INIS)

    Tellier, H.; Grandotto, M.

    1978-01-01

    Studies on uranium 238 resonance integral discrepancy were carried out for light water reactor physics. It was shown that using recently published resonance parameters and substituting a multilevel formalism to the usual Breit and Wigner formula reduced the well known discrepancy between two values of the uranium 238 effective resonance integral: the value calculated with the nuclear data and the one deduced from critical experiments. Since the cross section computed with these assumptions agrees quite well with the Oak-Ridge transmission data, it was used to obtain the self-shielding effect and the capture rate in light water lattices. The multiplication factor calculated with this method is found very close to the experimental value. Preliminary results for a set of benchmarks relative to several types of thermal neutron reactors lead to very low discrepancies. The reactivity loss is only 130 x 10 -5 instead of 650 x 10 -5 in the case of the usual libraries and the single level formula

  15. Integrating out resonances in strongly-coupled electroweak scenarios

    Directory of Open Access Journals (Sweden)

    Rosell Ignasi

    2017-01-01

    Full Text Available Accepting that there is a mass gap above the electroweak scale, the Electroweak Effective Theory (EWET is an appropriate tool to describe this situation. Since the EWET couplings contain information on the unknown high-energy dynamics, we consider a generic strongly-coupled scenario of electroweak symmetry breaking, where the known particle fields are coupled to heavier states. Then, and by integrating out these heavy fields, we study the tracks of the lightest resonances into the couplings. The determination of the low-energy couplings (LECs in terms of resonance parameters can be made more precise by considering a proper short-distance behaviour on the Lagrangian with heavy states, since the number of resonance couplings is then reduced. Notice that we adopt a generic non-linear realization of the electroweak symmetry breaking with a singlet Higgs.

  16. Electron Spin Resonance Measurement with Microinductor on Chip

    Directory of Open Access Journals (Sweden)

    Akio Kitagawa

    2011-01-01

    Full Text Available The detection of radicals on a chip is demonstrated. The proposed method is based on electron spin resonance (ESR spectroscopy and the measurement of high-frequency impedance of the microinductor fabricated on the chip. The measurement was by using a frequency sweep of approximately 100 MHz. The ESR spectra of di(phenyl-(2,4,6-trinitrophenyliminoazanium (DPPH dropped on the microinductor which is fabricated with CMOS 350-nm technology were observed at room temperature. The volume of the DPPH ethanol solution was 2 μL, and the number of spins on the micro-inductor was estimated at about 1014. The sensitivity is not higher than that of the standard ESR spectrometers. However, the result indicates the feasibility of a near field radical sensor in which the microinductor as a probe head and ESR signal processing circuit are integrated.

  17. Magnetic Barkhausen noise measurement by resonant coil method

    Energy Technology Data Exchange (ETDEWEB)

    Capo-Sanchez, J. [Departamento de Fisica, Facultad de Ciencias Naturales, Universidad de Oriente, Av. Patricio Lumumba s/n, 90500 Santiago de Cuba (Cuba)], E-mail: jcapo@usp.br; Padovese, L. [Departamento de Engenharia Mecanica, Escola Politecnica, Universidade de Sao Paulo, Av. Prof. Mello Moraes, 2231, 05508-900 Sao Paulo (Brazil)

    2009-09-15

    This paper describes a powerful new technique for nondestructive evaluation of ferromagnetic material. A method has been developed for measuring magnetic Barkhausen signals under different coil resonance frequencies. The measurements allow one to establish the behavior relating the power spectral density maximum and the resonant coil frequency. Time-frequency analysis of Barkhausen signals puts in evidence the tuning regions for each coil, and allows clear identification of each contribution to the Barkhausen signal spectrum. This concept was used in order to evaluate the relation between the degree of plastic deformation in carbon steel samples, and the power spectral density maximum at different resonance frequencies. This result also makes it possible to the selectively modify measurement sensibility to the magnetic Barkhausen signal by using different resonance frequencies.

  18. Integration of structural and functional magnetic resonance imaging in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Douaud, Gwenaëlle; Filippini, Nicola; Knight, Steven; Talbot, Kevin; Turner, Martin R

    2011-12-01

    Amyotrophic lateral sclerosis as a system failure is a concept supported by the finding of consistent extramotor as well as motor cerebral pathology. The functional correlates of the structural changes detected using advanced magnetic resonance imaging techniques such as diffusion tensor imaging and voxel-based morphometry have not been extensively studied. A group of 25 patients with amyotrophic lateral sclerosis was compared to healthy control subjects using a multi-modal neuroimaging approach comprising T(1)-weighted, diffusion-weighted and resting-state functional magnetic resonance imaging. Using probabilistic tractography, a grey matter connection network was defined based upon the prominent corticospinal tract and corpus callosum involvement demonstrated by white matter tract-based spatial statistics. This 'amyotrophic lateral sclerosis-specific' network included motor, premotor and supplementary motor cortices, pars opercularis and motor-related thalamic nuclei. A novel analysis protocol, using this disease-specific grey matter network as an input for a dual-regression analysis, was then used to assess changes in functional connectivity directly associated with this network. A spatial pattern of increased functional connectivity spanning sensorimotor, premotor, prefrontal and thalamic regions was found. A composite of structural and functional magnetic resonance imaging measures also allowed the qualitative discrimination of patients from controls. An integrated structural and functional connectivity approach therefore identified apparently dichotomous processes characterizing the amyotrophic lateral sclerosis cerebral network failure, in which there was increased functional connectivity within regions of decreased structural connectivity. Patients with slower rates of disease progression showed connectivity measures with values closer to healthy controls, raising the possibility that functional connectivity increases might not simply represent a

  19. Diamond electro-optomechanical resonators integrated in nanophotonic circuits

    Energy Technology Data Exchange (ETDEWEB)

    Rath, P.; Ummethala, S.; Pernice, W. H. P., E-mail: wolfram.pernice@kit.edu [Institute of Nanotechnology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen (Germany); Diewald, S. [Center for Functional Nanostructures, Karlsruhe Institute of Technology, 76131 Karlsruhe (Germany); Lewes-Malandrakis, G.; Brink, D.; Heidrich, N.; Nebel, C. [Fraunhofer Institute for Applied Solid State Physics, Tullastr. 72, 79108 Freiburg (Germany)

    2014-12-22

    Diamond integrated photonic devices are promising candidates for emerging applications in nanophotonics and quantum optics. Here, we demonstrate active modulation of diamond nanophotonic circuits by exploiting mechanical degrees of freedom in free-standing diamond electro-optomechanical resonators. We obtain high quality factors up to 9600, allowing us to read out the driven nanomechanical response with integrated optical interferometers with high sensitivity. We are able to excite higher order mechanical modes up to 115 MHz and observe the nanomechanical response also under ambient conditions.

  20. Integrated polymer micro-ring resonators for optical sensing applications

    Science.gov (United States)

    Girault, Pauline; Lorrain, Nathalie; Poffo, Luiz; Guendouz, Mohammed; Lemaitre, Jonathan; Carré, Christiane; Gadonna, Michel; Bosc, Dominique; Vignaud, Guillaume

    2015-03-01

    Micro-resonators (MR) have become a key element for integrated optical sensors due to their integration capability and their easy fabrication with low cost polymer materials. Nowadays, there is a growing need on MRs as highly sensitive and selective functions especially in the areas of food and health. The context of this work is to implement and study integrated micro-ring resonators devoted to sensing applications. They are fabricated by processing SU8 polymer as core layer and PMATRIFE polymer as lower cladding layer. The refractive index of the polymers and of the waveguide structure as a function of the wavelength is presented. Using these results, a theoretical study of the coupling between ring and straight waveguides has been undertaken in order to define the MR design. Sub-micronic gaps of 0.5 μm to 1 μm between the ring and the straight waveguides have been successfully achieved with UV (i-lines) photolithography. Different superstrates such as air, water, and aqueous solutions with glucose at different concentrations have been studied. First results show a good normalized transmission contrast of 0.98, a resonator quality factor around 1.5 × 104 corresponding to a coupling ratio of 14.7%, and ring propagation losses around 5 dB/cm. Preliminary sensing experiments have been performed for different concentrations of glucose; a sensitivity of 115 ± 8 nm/RIU at 1550 nm has been obtained with this couple of polymers.

  1. Integrability of the Gross-Pitaevskii equation with Feshbach resonance management

    International Nuclear Information System (INIS)

    Zhao Dun; Luo Honggang; Chai Huayue

    2008-01-01

    In this Letter we study the integrability of a class of Gross-Pitaevskii equations managed by Feshbach resonance in an expulsive parabolic external potential. By using WTC test, we find a condition under which the Gross-Pitaevskii equation is completely integrable. Under the present model, this integrability condition is completely consistent with that proposed by Serkin, Hasegawa, and Belyaeva [V.N. Serkin, A. Hasegawa, T.L. Belyaeva, Phys. Rev. Lett. 98 (2007) 074102]. Furthermore, this integrability can also be explicitly shown by a transformation, which can convert the Gross-Pitaevskii equation into the well-known standard nonlinear Schroedinger equation. By this transformation, each exact solution of the standard nonlinear Schroedinger equation can be converted into that of the Gross-Pitaevskii equation, which builds a systematical connection between the canonical solitons and the so-called nonautonomous ones. The finding of this transformation has a significant contribution to understanding the essential properties of the nonautonomous solitons and the dynamics of the Bose-Einstein condensates by using the Feshbach resonance technique

  2. Towards a fully integrated optical gyroscope using whispering gallery modes resonators

    Science.gov (United States)

    Amrane, T.; Jager, J.-B.; Jager, T.; Calvo, V.; Léger, J.-M.

    2017-11-01

    Since the developments of lasers and the optical fibers in the 70s, the optical gyroscopes have been subject to an intensive research to improve both their resolution and stability performances. However the best optical gyroscopes currently on the market, the ring laser gyroscope and the interferometer fiber optic gyroscope are still macroscopic devices and cannot address specific applications where size and weight constraints are critical. One solution to overcome these limitations could be to use an integrated resonator as a sensitive part to build a fully Integrated Optical Resonant Gyroscope (IORG). To keep a high rotation sensitivity, which is usually degraded when downsizing this kind of optical sensors based on the Sagnac effect, the resonator has to exhibit a very high quality factor (Q): as detailed in equation (1) where the minimum rotation rate resolution for an IORG is given as a function of the resonator characteristics (Q and diameter D) and of the global system optical system characteristics (i.e. SNR and bandwidth B), the higher the Q×D product, the lower the resolution.

  3. Resonance integral calculations for isolated rods containing oxides of 238U and 232Th

    International Nuclear Information System (INIS)

    Baker, V.C.; Marable, J.H.

    1980-02-01

    Results of resonance integral calculations for UO 2 and ThO 2 isolated rods are discussed. The calculations were performed with ENDF/B-IV cross-section data and the multigroup transport code ANISN. The findings reported demonstrate by comparison with semiempirical relationships (based on experimentally derived results) the suitability of the method used for determining resonance integrals. The calculations were based on a cylindrical rod in an H 2 O moderator of large radius. Multigroup cross sections were obtained by a MINX-SPHINX-AMMPX sequence, and ANISN was used to account for the neutron flux and capture rates. A special approach was used to determine a neutron source distribution such that the flux in the moderator region was forced to behave in an asymptotic way; thus, the ideal resonance integral experiment could be calculated. The UO 2 resonance integrals calculated were in exceptionally good agreement with experimental values based on isolated rods. The ThO 2 results were approximately 6% lower than experimental values, and efforts to understand the discrepancy are discussed. 8 figures, 7 tables

  4. Sound Transmission Loss Through a Corrugated-Core Sandwich Panel with Integrated Acoustic Resonators

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.; Zalewski, Bart F; Beck, Benjamin S.

    2014-01-01

    The goal of this study is to better understand the effect of structurally integrated resonators on the transmission loss of a sandwich panel. The sandwich panel has facesheets over a corrugated core, which creates long aligned chambers that run parallel to the facesheets. When ports are introduced through the facesheet, the long chambers within the core can be used as low-frequency acoustic resonators. By integrating the resonators within the structure they contribute to the static load bearing capability of the panel while also attenuating noise. An analytical model of a panel with embedded resonators is derived and compared with numerical simulations. Predictions show that acoustic resonators can significantly improve the transmission loss of the sandwich panel around the natural frequency of the resonators. In one configuration with 0.813 m long internal chambers, the diffuse field transmission loss is improved by more than 22 dB around 104 Hz. The benefit is achieved with no added mass or volume relative to the baseline structure. The embedded resonators are effective because they radiate sound out-of-phase with the structure. This results in destructive interference, which leads to less transmitted sound power.

  5. High Frequency LLC Resonant Converter with Magnetic Shunt Integrated Planar Transformer

    DEFF Research Database (Denmark)

    Li, Mingxiao; Ouyang, Ziwei; Andersen, Michael A. E.

    2018-01-01

    High Frequency LLC requires a smaller resonant inductance which is usually implemented by transformer leakage inductance. However, this small resonant inductance is difficult to deal with a wide input voltage range. This paper proposes a new method to implement a larger resonant inductance by using...... a magnetic shunt integrated into planar transformer. The switching frequency can be greatly narrowed by designing a smaller inductance ratio of magnetizing inductance to resonant inductance. Since this method can well deal with a wide input voltage range without adding extra inductor and increasing the size...... of the transformer, the power density can be improved. The precise leakage inductance calculation method for this transformer and detailed LLC converter design procedure are presented. A 280-380V and 48V-100W half bridge LLC resonant converter with 1 MHz resonant frequency is built to verify the design methodology....

  6. Integrated refractive index optical ring resonator detector for capillary electrophoresis.

    Science.gov (United States)

    Zhu, Hongying; White, Ian M; Suter, Jonathan D; Zourob, Mohammed; Fan, Xudong

    2007-02-01

    We developed a novel miniaturized and multiplexed, on-capillary, refractive index (RI) detector using liquid core optical ring resonators (LCORRs) for future development of capillary electrophoresis (CE) devices. The LCORR employs a glass capillary with a diameter of approximately 100 mum and a wall thickness of a few micrometers. The circular cross section of the capillary forms a ring resonator along which the light circulates in the form of the whispering gallery modes (WGMs). The WGM has an evanescent field extending into the capillary core and responds to the RI change due to the analyte conducted in the capillary, thus permitting label-free measurement. The resonating nature of the WGM enables repetitive light-analyte interaction, significantly enhancing the LCORR sensitivity. This LCORR architecture achieves dual use of the capillary as a sensor head and a CE fluidic channel, allowing for integrated, multiplexed, and noninvasive on-capillary detection at any location along the capillary. In this work, we used electro-osmotic flow and glycerol as a model system to demonstrate the fluid transport capability of the LCORRs. In addition, we performed flow speed measurement on the LCORR to demonstrate its flow analysis capability. Finally, using the LCORR's label-free sensing mechanism, we accurately deduced the analyte concentration in real time at a given point on the capillary. A sensitivity of 20 nm/RIU (refractive index units) was observed, leading to an RI detection limit of 10-6 RIU. The LCORR marries photonic technology with microfluidics and enables rapid on-capillary sample analysis and flow profile monitoring. The investigation in this regard will open a door to novel high-throughput CE devices and lab-on-a-chip sensors in the future.

  7. Analysis and Modeling of Integrated Magnetics for LLC resonant Converters

    DEFF Research Database (Denmark)

    Li, Mingxiao; Ouyang, Ziwei; Zhao, Bin

    2017-01-01

    Shunt-inserted transformers are widely used toobtain high leakage inductance. This paper investigates thismethod in depth to make it applicable to integrate resonantinductor for the LLC resonant converters. The analysis andmodel of magnetizing inductance and leakage inductance forshunt...... transformers can provide a significantdifference. The way to obtain the desirable magnetizing andleakage inductance value for LLC resonant converters issimplified by the creation of air gaps together with a magneticshunt. The calculation and relation are validated by finiteelement analysis (FEA) simulations...

  8. Short-circuit protection of LLC resonant converter using voltages across resonant tank elements

    Directory of Open Access Journals (Sweden)

    Denys Igorovych Zaikin

    2015-06-01

    Full Text Available This paper describes two methods for the short-circuit protection of the LLC resonant converter. One of them uses the voltage across the capacitor and the other uses the voltage across the inductor of the resonant tank. These voltages can be processed (integrated or differentiated to recover the resonant tank current. The two circuits illustrated in the described methods make it possible to develop a robust LLC converter design and to avoid using lossy current measurement elements, such as a shunt resistor or current transformer. The methods also allow measuring resonant tank current without breaking high-current paths and connecting the measuring circuit in parallel with the inductor or capacitor of the resonant tank. Practical implementations of these indirect current measurements have been experimentally tested for the short-circuit protection of the 1600 W LLC converter.

  9. Resonance integral analytical calculation considering shadowing effect. Calculo analitico da integral de ressonancia considerando o efeito de sombreamento

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, M A.M. [NUCLEN, Rio de Janeiro, RJ (Brazil); Martinez, A S [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1990-01-01

    It is presented a method for the Resonance Integral Calculation in the fuel and moderator regions, including the shadowing effect. This effect appears due to the presence of several fuel rods in a infinite moderator region. The method is based on the approximations to the J ({xi}, {beta}) function and theirs partial derivatives in relation to {beta}. The dependence of the Resonance Integral in the J ({xi}, {beta}) comes from the rational approximation to the neutron escape probability. The final results were obtained in a very simple and fast way, and they show the good accuracy of the method. (author).

  10. Europium resonance parameters from neutron capture and transmission measurements in the energy range 0.01–200 eV

    International Nuclear Information System (INIS)

    Leinweber, G.; Barry, D.P.; Burke, J.A.; Rapp, M.J.; Block, R.C.; Danon, Y.; Geuther, J.A.; Saglime III, F.J.

    2014-01-01

    Highlights: • Metal samples were sealed and imaged with X-rays to determine sample uniformity. • Eleven new resonances were identified below 100 eV. • The resonance regions of 151 Eu and 153 Eu have been extended from 100 to 200 eV. • The thermal total cross section for 151 Eu was measured, up (9 ± 3)% from ENDF/B-VII.1. • Radiation widths were assigned for all resonances from experimental data. - Abstract: Europium is a good absorber of neutrons suitable for use as a nuclear reactor control material. It is also a fission product in the low-yield tail at the high end of the fission fragment mass distribution. Measurements have been made of the stable isotopes with natural and enriched samples. The linear electron accelerator center (LINAC) at the Rensselaer Polytechnic Institute (RPI) was used to explore neutron interactions with europium in the energy region from 0.01 to 200 eV. Neutron capture and transmission measurements were performed by the time-of-flight technique. Two transmission measurements were performed at flight paths of 15 and 25 m with 6 Li glass scintillation detectors. The neutron capture measurements were performed at a flight path of 25 m with a 16-segment sodium iodide multiplicity detector. Resonance parameters were extracted from the data using the multilevel R-matrix Bayesian code SAMMY. A table of resonance parameters and their uncertainties is presented. To prevent air oxidation metal samples were sealed in airtight aluminum cans in an inert environment. Metal samples of natural europium, 47.8 atom% 151 Eu, 52.2 atom% 153 Eu, as well as metal samples enriched to 98.77 atom% 153 Eu were measured. The measured neutron capture resonance integral for 153 Eu is (9.9 ± 0.4)% larger than ENDF/B-VII.1. The capture resonance integral for 151 Eu is (7 ± 1)% larger than ENDF/B-VII.1. Another significant finding from these measurements was a significant increase in thermal total cross section for 151 Eu, up (9 ± 3)% from ENDF/B-VII.1

  11. A film bulk acoustic resonator-based high-performance pressure sensor integrated with temperature control system

    International Nuclear Information System (INIS)

    Zhang, Mengying; Zhao, Zhan; Du, Lidong; Fang, Zhen

    2017-01-01

    This paper presented a high-performance pressure sensor based on a film bulk acoustic resonator (FBAR). The support film of the FBAR chip was made of silicon nitride and the part under the resonator area was etched to enhance the sensitivity and improve the linearity of the pressure sensor. A micro resistor temperature sensor and a micro resistor heater were integrated in the chip to monitor and control the operating temperature. The sensor chip was fabricated, and packaged in an oscillator circuit for differential pressure detection. When the detected pressure ranged from  −100 hPa to 600 hPa, the sensitivity of the improved FBAR pressure sensor was  −0.967 kHz hPa −1 , namely  −0.69 ppm hPa −1 , which was 19% higher than that of existing sensors with a complete support film. The nonlinearity of the improved sensor was less than  ±0.35%, while that of the existing sensor was  ±5%. To eliminate measurement errors from humidity, the temperature control system integrated in the sensor chip controlled the temperature of the resonator up to 75 °C, with accuracy of  ±0.015 °C and power of 20 mW. (paper)

  12. Micro-resonators based on integrated polymer technology for optical sensing

    OpenAIRE

    Girault , Pauline; Lemaitre , Jonathan; Guendouz , Mohammed; Lorrain , Nathalie; Poffo , Luiz; Gadonna , Michel; Bosc , Dominique

    2014-01-01

    International audience; Research on sensors has experienced a noticeable development over the last decades especially in label free optical biosensors. However, compact sensors without markers for rapid, reliable and inexpensive detection of various substances induces a significant research of new technological solutions. The context of this work is the development of a sensor based on easily integrated and inexpensive micro-resonator (MR) component in integrated optics, highly sensitive and ...

  13. Ferromagnetic linewidth measurements employing electrodynamic model of the magnetic plasmon resonance

    Science.gov (United States)

    Krupka, Jerzy; Aleshkevych, Pavlo; Salski, Bartlomiej; Kopyt, Pawel

    2018-02-01

    The mode of uniform precession, or Kittel mode, in a magnetized ferromagnetic sphere, has recently been proven to be the magnetic plasmon resonance. In this paper we show how to apply the electrodynamic model of the magnetic plasmon resonance for accurate measurements of the ferromagnetic resonance linewidth ΔH. Two measurement methods are presented. The first one employs Q-factor measurements of the magnetic plasmon resonance coupled to the resonance of an empty metallic cavity. Such coupled modes are known as magnon-polariton modes, i.e. hybridized modes between the collective spin excitation and the cavity excitation. The second one employs direct Q-factor measurements of the magnetic plasmon resonance in a filter setup with two orthogonal semi-loops used for coupling. Q-factor measurements are performed employing a vector network analyser. The methods presented in this paper allow one to extend the measurement range of the ferromagnetic resonance linewidth ΔH well beyond the limits of the commonly used measurement standards in terms of the size of the samples and the lowest measurable linewidths. Samples that can be measured with the newly proposed methods may have larger size as compared to the size of samples that were used in the standard methods restricted by the limits of perturbation theory.

  14. Nonlinear resonance in Duffing oscillator with fixed and integrative ...

    Indian Academy of Sciences (India)

    We study the nonlinear resonance, one of the fundamental phenomena in nonlinear oscillators, in a damped and periodically-driven Duffing oscillator with two types of time-delayed feedbacks, namely, fixed and integrative. Particularly, we analyse the effect of the time-delay parameter and the strength of the ...

  15. Nonlinear resonance in Duffing oscillator with fixed and integrative ...

    Indian Academy of Sciences (India)

    2012-03-02

    Mar 2, 2012 ... Abstract. We study the nonlinear resonance, one of the fundamental phenomena in nonlinear oscillators, in a damped and periodically-driven Duffing oscillator with two types of time-delayed feedbacks, namely, fixed and integrative. Particularly, we analyse the effect of the time-delay parameter α and the ...

  16. Measurements of the effective total and resonance absorption cross sections for zircaloy-2 and zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Kocic, A; Markovic, V [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1967-04-15

    Zirconium and zircaloy-2 alloy, as constructive materials, have found wide application in reactor technology, especially in heavy water systems for two reasons: a) low neutron absorption cross section, b) good mechanical properties. The thickness of the zirconium and zircaloy-2 for different applications varies from several tenths of a millimeter to about ten millimeters. Therefore, to calculate reactor systems it is desirable to know the effective neutron absorption cross section for the range of thicknesses mention above. The thermal neutron cross sections for these materials are low and no appreciable variation of the effective neutron cross section occurs even for the largest thicknesses. However, this is not true for effective resonance absorption. On the other hand, due to the lack of detailed knowledge of the zirconium resonances, calculations of the effective resonance integrals cannot be performed. Therefore it is necessary to measure the effective total and resonance absorption cross section for zirconium (author)

  17. Coupling thermal atomic vapor to an integrated ring resonator

    International Nuclear Information System (INIS)

    Ritter, R; Kübler, H; Pfau, T; Löw, R; Gruhler, N; Pernice, W H P

    2016-01-01

    Strongly interacting atom–cavity systems within a network with many nodes constitute a possible realization for a quantum internet which allows for quantum communication and computation on the same platform. To implement such large-scale quantum networks, nanophotonic resonators are promising candidates because they can be scalably fabricated and interconnected with waveguides and optical fibers. By integrating arrays of ring resonators into a vapor cell we show that thermal rubidium atoms above room temperature can be coupled to photonic cavities as building blocks for chip-scale hybrid circuits. Although strong coupling is not yet achieved in this first realization, our approach provides a key step towards miniaturization and scalability of atom–cavity systems. (paper)

  18. INTER, ENDF/B Thermal Cross-Sections, Resonance Integrals, G-Factors Calculation

    International Nuclear Information System (INIS)

    Dunford, Charles L.

    2007-01-01

    1 - Description of program or function: INTER calculates thermal cross sections, g-factors, resonance integrals, fission spectrum averaged cross sections and 14.0 MeV (or other energy) cross sections for major reactions in an ENDF-6 or ENDF-5 format data file. Version 7.01 (Jan 2005): set success flag after return from beginning. 2 - Method of solution: INTER performs integrations by using the trapezoidal rule

  19. Measurement of optical Feshbach resonances in an ideal gas.

    Science.gov (United States)

    Blatt, S; Nicholson, T L; Bloom, B J; Williams, J R; Thomsen, J W; Julienne, P S; Ye, J

    2011-08-12

    Using a narrow intercombination line in alkaline earth atoms to mitigate large inelastic losses, we explore the optical Feshbach resonance effect in an ultracold gas of bosonic (88)Sr. A systematic measurement of three resonances allows precise determinations of the optical Feshbach resonance strength and scaling law, in agreement with coupled-channel theory. Resonant enhancement of the complex scattering length leads to thermalization mediated by elastic and inelastic collisions in an otherwise ideal gas. Optical Feshbach resonance could be used to control atomic interactions with high spatial and temporal resolution.

  20. Measurement of Optical Feshbach Resonances in an Ideal Gas

    International Nuclear Information System (INIS)

    Blatt, S.; Nicholson, T. L.; Bloom, B. J.; Williams, J. R.; Thomsen, J. W.; Ye, J.; Julienne, P. S.

    2011-01-01

    Using a narrow intercombination line in alkaline earth atoms to mitigate large inelastic losses, we explore the optical Feshbach resonance effect in an ultracold gas of bosonic 88 Sr. A systematic measurement of three resonances allows precise determinations of the optical Feshbach resonance strength and scaling law, in agreement with coupled-channel theory. Resonant enhancement of the complex scattering length leads to thermalization mediated by elastic and inelastic collisions in an otherwise ideal gas. Optical Feshbach resonance could be used to control atomic interactions with high spatial and temporal resolution.

  1. Set up of a method for the adjustment of resonance parameters on integral experiments

    International Nuclear Information System (INIS)

    Blaise, P.

    1996-01-01

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.)

  2. Differential interferometer for measurement of displacement of laser resonator mirrors

    Science.gov (United States)

    Macúchová, Karolina; Němcová, Šárka; Hošek, Jan

    2015-01-01

    This paper covers a description and a technique of a possible optical method of mode locking within a laser resonator. The measurement system is a part of instrumentation of laser-based experiment OSQAR at CERN. The OSQAR experiment aims at search of axions, axion-like particles and measuring of ultra-fine vacuum magnetic birefringence. It uses a laser resonator to enhance the coupling constant of hypothetical photon-to-axion conversion. The developed locking-in technique is based on differential interferometry. Signal obtained from the measurement provide crucial information for adaptive control of the locking-in of the resonator in real time. In this paper we propose several optical setups used for measurement and analysis of mutual position of the resonator mirrors. We have set up a differential interferometer under our laboratory conditions. We have done measurements with hemi-spherical cavity resonator detuned with piezo crystals. The measurement was set up in a single plane. Laser light was directed through half-wave retarder to a polarizing beam splitter and then converted to circular polarization by lambda/4 plates. After reflection at the mirrors, the beam is recombined in a beam splitter, sent to analyser and non-polarizing beam splitter and then inspected by two detectors with mutually perpendicular polarizers. The 90 degrees phase shift between the two arms allows precise analysis of a mutual distance change of the mirrors. Because our setup was sufficiently stable, we were able to measure the piezo constant and piezo hysteresis. The final goal is to adapt the first prototype to 23 m resonator and measure the displacement in two planes.

  3. Evaluation of thermal neutron cross-sections and resonance integrals of protactinium, americium, curium, and berkelium isotopes

    International Nuclear Information System (INIS)

    Belanova, T.S.

    1994-12-01

    Data on the thermal neutron fission and capture cross-sections as well as their corresponding resonance integrals are reviewed and analysed. The data are classified according to the form of neutron spectra under investigation. The weighted mean values of the cross-sections and resonance integrals for every type of neutron spectra were adopted as evaluated data. (author). 87 refs, 2 tabs

  4. Measuring the Popular Resonance of Daesh’s Propoganda

    Directory of Open Access Journals (Sweden)

    William Marcellino

    2017-03-01

    Full Text Available We describe an innovative approach to social media analysis, combining corpus linguists and statistical methods to measure the resonance of Daesh's propaganda to a sample population (Eqypt. The findings from this research effort demonstrate that: (1 Daesh's messaging is measurable and distinct from other Salafi groups, such as the Egyptian Muslim Brotherhood; (2 while Daesh’s messaging generally do not resonate with Egyptians, its uptake increased in Upper Egypt and the Sinai regions during 2014; and (3 this method can be applied more broadly to measure the spread of violent extremist messaging across regional populations over time.

  5. Expected count rate for the Self- Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium); Borella, Alessandro; Van der Meer, Klaas [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in the fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron flux integrated over the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach considered in this study consists in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types are used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the count rate that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of count rate and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the count rate by increasing the detector size. The study shows that the highest count rate is achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the count rate associated to each detector type

  6. Integrated variable projection approach (IVAPA) for parallel magnetic resonance imaging.

    Science.gov (United States)

    Zhang, Qiao; Sheng, Jinhua

    2012-10-01

    Parallel magnetic resonance imaging (pMRI) is a fast method which requires algorithms for the reconstructing image from a small number of measured k-space lines. The accurate estimation of the coil sensitivity functions is still a challenging problem in parallel imaging. The joint estimation of the coil sensitivity functions and the desired image has recently been proposed to improve the situation by iteratively optimizing both the coil sensitivity functions and the image reconstruction. It regards both the coil sensitivities and the desired images as unknowns to be solved for jointly. In this paper, we propose an integrated variable projection approach (IVAPA) for pMRI, which integrates two individual processing steps (coil sensitivity estimation and image reconstruction) into a single processing step to improve the accuracy of the coil sensitivity estimation using the variable projection approach. The method is demonstrated to be able to give an optimal solution with considerably reduced artifacts for high reduction factors and a low number of auto-calibration signal (ACS) lines, and our implementation has a fast convergence rate. The performance of the proposed method is evaluated using a set of in vivo experiment data. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Measurement of the Z Resonance Parameters at LEP

    CERN Document Server

    Barate, R; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Merle, E; Minard, M N; Pietrzyk, B; Alemany, R; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Orteu, S; Pacheco, A; Park, I C; Perlas, J A; Riu, I; Sánchez, F; Colaleo, A; Creanza, D; De Palma, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Bazarko, A; Becker, U; Boix, G; Bird, F; Blucher, E; Bonvicini, G; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Ciulli, V; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Greening, T C; Hagelberg, R; Halley, A W; Hansen, J B; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Knobloch, J; Lazeyras, Pierre; Lehraus, Ivan; Maley, P; Mato, P; May, J; Moutoussi, A; Ranjard, F; Rolandi, Luigi; Schlatter, W D; Schmitt, M; Schneider, O; Spagnolo, P; Tejessy, W; Teubert, F; Tomalin, I R; Tournefier, E; Veenhof, R; Wiedenmann, W; Wright, A E; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Bertelsen, H; Fernley, T; Hansen, F; Hansen, J D; Hansen, J R; Hansen, P H; Lindahl, A; Møllerud, R; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Rougé, A; Rumpf, M; Swynghedauw, M; Tanaka, R; Verderi, M; Videau, H L; Focardi, E; Parrini, G; Zachariadou, K; Cavanaugh, R J; Corden, M; Georgiopoulos, C H; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Picchi, P; Colrain, P; ten Have, I; Hughes, I S; Knowles, I G; Lynch, J G; Morton, W T; Raine, C; Reeves, P; O'Shea, V; Scarr, J M; Smith, K; Thompson, A S; Turnbull, R M; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Marinelli, N; Nash, J; Sciabà, A; Sedgbeer, J K; Thomson, E; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bowdery, C K; Buck, P G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Keemer, N R; Robertson, N A; Sloan, Terence; Snow, S W; Williams, M I; Bauerdick, L A T; Van Gemmeren, P; Giehl, I; Jakobs, K; Kasemann, M; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Schmelling, M; Wachsmuth, H W; Wanke, R; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Carr, J; Coyle, P; Etienne, F; Motsch, F; Payre, P; Rousseau, D; Talby, M; Thulasidas, M; Aleppo, M; Antonelli, M; Ragusa, F; Büscher, V; Dietl, H; Ganis, G; Hüttmann, K; Lütjens, G; Mannert, C; Männer, W; Moser, H G; Schael, S; Settles, Ronald; Seywerd, H C J; Stenzel, H; Wolf, G; Azzurri, P; Boucrot, J; Callot, O; Chen, S; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacholkowska, A; Le Diberder, F R; Lefrançois, J; Lutz, A M; Schune, M H; Veillet, J J; Videau, I; Zerwas, D; Bagliesi, G; Bettarini, S; Boccali, T; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sguazzoni, G; Steinberger, Jack; Tenchini, Roberto; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Cowan, G D; Green, M G; Medcalf, T; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Edwards, M; Haywood, S J; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Cartwright, S L; Combley, F; Lehto, M H; Thompson, L F; Affholderbach, K; Barberio, E; Böhrer, A; Brandt, S; Burkhardt, H; Feigl, E; Grupen, Claus; Hess, J; Lutters, G; Meinhard, H; Minguet-Rodríguez, J A; Mirabito, L; Misiejuk, A; Neugebauer, E; Prange, G; Rivera, F; Saraiva, P; Schäfer, U; Sieler, U; Smolik, L; Stephan, F; Trier, H; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pitis, L; Kim, H; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Cinabro, D; Conway, J S; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; Jin, S; Johnson, R P; Kile, J; McNamara, P A; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Sharma, V; Walsh, A M; Walsh, J; Wear, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    2000-01-01

    The properties of the Z resonance are measured from the analysis of 4.5 million Z decays into fermion pairs collected with the \\Aleph\\ detector at L EP. The data are consistent with lepton universality. The resonance parameters are measured to be $\\MZ=(91.1885 \\pm 0.0031)~\\Gevcc$, $\\GZ= (2.4951 \\pm 0.0043)~\\GeV$, $\\spol=(41.559 \\pm 0.058)$~nb and, combining the three lepton flavours $\\Rl= 20.725\\pm 0.039$. The corresponding number of light neutrino species is $N_{\

  8. Analysis and optimization of acoustic wave micro-resonators integrating piezoelectric zinc oxide layers

    Science.gov (United States)

    Mortada, O.; Zahr, A. H.; Orlianges, J.-C.; Crunteanu, A.; Chatras, M.; Blondy, P.

    2017-02-01

    This paper reports on the design, simulation, fabrication, and test results of ZnO-based contour-mode micro-resonators integrating piezoelectric zinc oxide (ZnO) layers. The inter-digitated (IDT) type micro-resonators are fabricated on ZnO films and suspended top of 2 μm thick silicon membranes using silicon-on insulator technology. We analyze several possibilities of increasing the quality factor (Q) and the electromechanical coupling coefficient (kt2) of the devices by varying the numbers and lengths of the IDT electrodes and using different thicknesses of the ZnO layer. We designed and fabricated IDTs of different finger numbers (n = 25, 40, 50, and 80) and lengths (L = 100/130/170/200 μm) for three different thicknesses of ZnO films (200, 600, and 800 nm). The measured Q factor confirms that reducing the length and the number of IDT fingers enables us to reach better electrical performances at resonant frequencies around 700 MHz. The extracted results for an optimized micro-resonator device having an IDT length of 100 μm and 40 finger electrodes show a Q of 1180 and a kt2 of 7.4%. We demonstrate also that the reduction of the ZnO thickness from 800 nm to 200 nm increases the quality factor from 430 to 1600, respectively, around 700 MHz. Experimental data are in very good agreement with theoretical simulations of the fabricated devices

  9. Atlas of neutron resonances

    CERN Document Server

    Mughabghab, Said

    2018-01-01

    Atlas of Neutron Resonances: Resonance Properties and Thermal Cross Sections Z= 1-60, Sixth Edition, contains an extensive list of detailed individual neutron resonance parameters for Z=1-60, as well as thermal cross sections, capture resonance integrals, average resonance parameters and a short survey of the physics of thermal and resonance neutrons. The long introduction contains: nuclear physics formulas aimed at neutron physicists; topics of special interest such as valence neutron capture, nuclear level density parameters, and s-, p-, and d-wave neutron strength functions; and various comparisons of measured quantities with the predictions of nuclear models, such as the optical model. As in the last edition, additional features have been added to appeal to a wider spectrum of users. These include: spin-dependent scattering lengths that are of interest to solid-state physicists, nuclear physicists and neutron evaluators; calculated and measured Maxwellian average 5-keV and 30-keV capture cross sections o...

  10. Single-frequency, fully integrated, miniature DPSS laser based on monolithic resonator

    Science.gov (United States)

    Dudzik, G.; Sotor, J.; Krzempek, K.; Soboń, G.; Abramski, K. M.

    2014-02-01

    We present a single frequency, stable, narrow linewidth, miniature laser sources operating at 532 nm (or 1064 nm) based on a monolithic resonators. Such resonators utilize birefringent filters formed by YVO4 beam displacer and KTP or YVO4 crystals to force single frequency operation at 532 nm or 1064 nm, respectively. In both configurations Nd:YVO4 gain crystal is used. The resonators dimensions are 1x1x10.5 mm3 and 1x1x8.5 mm3 for green and infrared configurations, respectively. Presented laser devices, with total dimensions of 40x52x120 mm3, are fully equipped with driving electronics, pump diode, optical and mechanical components. The highly integrated (36x15x65 mm3) low noise driving electronics with implemented digital PID controller was designed. It provides pump current and resonator temperature stability of ±30 μA@650 mA and ±0,003ºC, respectively. The laser parameters can be set and monitored via the USB interface by external application. The developed laser construction is universal. Hence, the other wavelengths can be obtained only by replacing the monolithic resonator. The optical output powers in single frequency regime was at the level of 42 mW@532 nm and 0.5 W@1064 nm with the long-term fluctuations of ±0.85 %. The linewidth and the passive frequency stability under the free running conditions were Δν < 100 kHz and 3ṡ10-9@1 s integration time, respectively. The total electrical power supply consumption of laser module was only 4 W. Presented compact, single frequency laser operating at 532 nm and 1064 nm may be used as an excellent source for laser vibrometry, interferometry or seed laser for fiber amplifiers.

  11. Integrated phononic crystal resonators based on adiabatically-terminated phononic crystal waveguides

    Directory of Open Access Journals (Sweden)

    Razi Dehghannasiri

    2016-12-01

    Full Text Available In this letter, we demonstrate a new design for integrated phononic crystal (PnC resonators based on confining acoustic waves in a heterogeneous waveguide-based PnC structure. In this architecture, a PnC waveguide that supports a single mode at the desired resonance frequencies is terminated by two waveguide sections with no propagating mode at those frequencies (i.e., have mode gap. The proposed PnC resonators are designed through combining the spatial-domain and the spatial-frequency domain (i.e., the k-domain analysis to achieve a smooth mode envelope. This design approach can benefit both membrane-based and surface-acoustic-wave-based architectures by confining the mode spreading in k-domain that leads to improved electromechanical excitation/detection coupling and reduced loss through propagating bulk modes.

  12. Measurement of J/ψ resonance parameters

    International Nuclear Information System (INIS)

    Bai Jingzhi; Chen Guangpei; Chen Shaomin

    1995-01-01

    The cross sections of e + e - →hadrons, e + e - , μ + μ - have been measured in the vicinity of J/ψ resonance at BES/BEPC. The fit of the observed cross sections gives the new results of J/ψ resonance parameters: the partial widths to hadrons, electrons and muons are Γ h = 74.1 +- 8.1 keV, Γ e = 5.14 +- 0.39 keV and Γ μ = 5.13 +-0.52 keV respectively; the total width Γ = 84.4 +- 8.9 keV; the branching fractions Γ h /Γ = (87.8 +- 0.5)%, Γ e /Γ (6.09 +- 0.33)%, and Γ μ /Γ = (6.08 +- 0.33)%

  13. Measurement of the profile and intensity of the solar He I lambda 584-A resonance line

    Science.gov (United States)

    Maloy, J. O.; Hartmann, U. G.; Judge, D. L.; Carlson, R. W.

    1978-01-01

    The intensity and profile of the helium resonance line at 584 A from the entire disk of the sun was investigated by using a rocket-borne helium-filled spectrometer and a curve-of-growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 + or - 10 mA, while the integrated intensity was measured to be 2.6 + or - 1.3 billion photons/s per sq cm at solar activity levels of F(10.7) = 90.8 x 10 to the -22nd per sq m/Hz and Rz = 27. The measured line width is in good agreement with previous spectrographic measurements, but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of 20 + or - 10 billion photons/s per sq cm/A is in good agreement with values inferred from airglow measurements.

  14. Integrated unaligned resonant modulator tuning

    Energy Technology Data Exchange (ETDEWEB)

    Zortman, William A.; Lentine, Anthony L.

    2017-10-03

    Methods and systems for tuning a resonant modulator are disclosed. One method includes receiving a carrier signal modulated by the resonant modulator with a stream of data having an approximately equal number of high and low bits, determining an average power of the modulated carrier signal, comparing the average power to a predetermined threshold, and operating a tuning device coupled to the resonant modulator based on the comparison of the average power and the predetermined threshold. One system includes an input structure, a plurality of processing elements, and a digital control element. The input structure is configured to receive, from the resonant modulator, a modulated carrier signal. The plurality of processing elements are configured to determine an average power of the modulated carrier signal. The digital control element is configured to operate a tuning device coupled to the resonant modulator based on the average power of the modulated carrier signal.

  15. A near-field scanning microwave microscope based on a superconducting resonator for low power measurements.

    Science.gov (United States)

    de Graaf, S E; Danilov, A V; Adamyan, A; Kubatkin, S E

    2013-02-01

    We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.

  16. Coupling ultracold atoms to a superconducting coplanar waveguide resonator

    OpenAIRE

    Hattermann, H.; Bothner, D.; Ley, L. Y.; Ferdinand, B.; Wiedmaier, D.; Sárkány, L.; Kleiner, R.; Koelle, D.; Fortágh, J.

    2017-01-01

    We demonstrate coupling of magnetically trapped ultracold $^87$Rb ground state atoms to a coherently driven superconducting coplanar resonator on an integrated atom chip. We measure the microwave field strength in the cavity through observation of the AC shift of the hyperfine transition frequency when the cavity is driven off-resonance from the atomic transition. The measured shifts are used to reconstruct the field in the resonator, in close agreement with transmission measurements of the c...

  17. Microstrip resonators for electron paramagnetic resonance experiments

    Science.gov (United States)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  18. Microstrip resonators for electron paramagnetic resonance experiments.

    Science.gov (United States)

    Torrezan, A C; Mayer Alegre, T P; Medeiros-Ribeiro, G

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5 x 10(10) spins/GHz(1/2) despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  19. Measure and integration theory

    CERN Document Server

    Burckel, Robert B

    2001-01-01

    This book gives a straightforward introduction to the field as it is nowadays required in many branches of analysis and especially in probability theory. The first three chapters (Measure Theory, Integration Theory, Product Measures) basically follow the clear and approved exposition given in the author's earlier book on ""Probability Theory and Measure Theory"". Special emphasis is laid on a complete discussion of the transformation of measures and integration with respect to the product measure, convergence theorems, parameter depending integrals, as well as the Radon-Nikodym theorem. The fi

  20. Micro-machined resonator oscillator

    Science.gov (United States)

    Koehler, Dale R.; Sniegowski, Jeffry J.; Bivens, Hugh M.; Wessendorf, Kurt O.

    1994-01-01

    A micro-miniature resonator-oscillator is disclosed. Due to the miniaturization of the resonator-oscillator, oscillation frequencies of one MHz and higher are utilized. A thickness-mode quartz resonator housed in a micro-machined silicon package and operated as a "telemetered sensor beacon" that is, a digital, self-powered, remote, parameter measuring-transmitter in the FM-band. The resonator design uses trapped energy principles and temperature dependence methodology through crystal orientation control, with operation in the 20-100 MHz range. High volume batch-processing manufacturing is utilized, with package and resonator assembly at the wafer level. Unique design features include squeeze-film damping for robust vibration and shock performance, capacitive coupling through micro-machined diaphragms allowing resonator excitation at the package exterior, circuit integration and extremely small (0.1 in. square) dimensioning. A family of micro-miniature sensor beacons is also disclosed with widespread applications as bio-medical sensors, vehicle status monitors and high-volume animal identification and health sensors. The sensor family allows measurement of temperatures, chemicals, acceleration and pressure. A microphone and clock realization is also available.

  1. Wireless passive polymer-derived SiCN ceramic sensor with integrated resonator/antenna

    Science.gov (United States)

    Li, Yan; Yu, Yuxi; San, Haisheng; Wang, Yansong; An, Linan

    2013-10-01

    This paper presents a passive wireless polymer-derived silicon carbonitride (SiCN) ceramic sensor based on cavity radio frequency resonator together with integrated slot antenna. The effect of the cavity sensor dimensions on the Q-factor and resonant frequency is investigated by numerical simulation. A sensor with optimal dimensions is designed and fabricated. It is demonstrated that the sensor signal can be wirelessly detected at distances up to 20 mm. Given the high-temperature stability of the SiCN, the sensor is very promising for high-temperature wireless sensing applications.

  2. Invited Article: Electrically tunable silicon-based on-chip microdisk resonator for integrated microwave photonic applications

    Directory of Open Access Journals (Sweden)

    Weifeng Zhang

    2016-11-01

    Full Text Available Silicon photonics with advantages of small footprint, compatibility with the mature CMOS fabrication technology, and its potential for seamless integration with electronics is making a significant difference in realizing on-chip integration of photonic systems. A microdisk resonator (MDR with a strong capacity in trapping and storing photons is a versatile element in photonic integrated circuits. Thanks to the large index contrast, a silicon-based MDR with an ultra-compact footprint has a great potential for large-scale and high-density integrations. However, the existence of multiple whispering gallery modes (WGMs and resonance splitting in an MDR imposes inherent limitations on its widespread applications. In addition, the waveguide structure of an MDR is incompatible with that of a lateral PN junction, which leads to the deprivation of its electrical tunability. To circumvent these limitations, in this paper we propose a novel design of a silicon-based MDR by introducing a specifically designed slab waveguide to surround the disk and the lateral sides of the bus waveguide to suppress higher-order WGMs and to support the incorporation of a lateral PN junction for electrical tunability. An MDR based on the proposed design is fabricated and its optical performance is evaluated. The fabricated MDR exhibits single-mode operation with a free spectral range of 28.85 nm. Its electrical tunability is also demonstrated and an electro-optic frequency response with a 3-dB modulation bandwidth of ∼30.5 GHz is measured. The use of the fabricated MDR for the implementation of an electrically tunable optical delay-line and a tunable fractional-order temporal photonic differentiator is demonstrated.

  3. Influence of the resonance integral value on the fuel cycle characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Graziani, G; Trauwaert, E

    1972-04-24

    The problem that is considered here is to determine what can be done about a variation in resonance integral when the complete geometry of the reactor and of the fuel elements are fixed, leaving as only free parameters the amount of heavy metal and the enrichment to put in the fuel pins.

  4. Integration of Resonant Coil for Wireless Power Transfer and Implantable Antenna for Signal Transfer

    Directory of Open Access Journals (Sweden)

    Dong-Wook Seo

    2016-01-01

    Full Text Available We propose the integration of the resonant coil for wireless power transfer (WPT and the implantable antenna for physiological signal transfer. The integration allows for a compact biomedical implantable system such as electrocardiogram (ECG recorder and pacemaker. While the resonant coils resonate at the frequency of 13.56 MHz for the WPT, the implantable antenna works in the medical implant communications service (MICS band of 402–405 MHz for wireless communications. They share the narrow substrate area of a bar-type shape; the coil has the current path on the outer part of the substrate and the meandered planar inverted-F antenna (PIFA occupies the inside of the coil. To verify the potentials of the proposed structure, a prototype is fabricated and tested in vitro. The power transfer efficiency (PTE of about 20% is obtained at a distance of 15 mm and the antenna gain of roughly −40 dBi is achieved.

  5. Measurement of elastic modules of structural ceramic by acoustic resonance

    International Nuclear Information System (INIS)

    Ahn, Bong Young; Lee Seong Suck; Kim, Young Gil

    1993-01-01

    Elastic moduli of structural ceramic materials, Al 2 O 3 , SiC, Si 3 N 4 , were measured by acoustic resonance method. Young's modulus, shear modulus, and Poisson's ratio were calculated from the torsional and flexural resonant frequencies, densities, and the dimensions of the specimen. The results by acoustic resonance method were compared with the results by ultrasonic method and the differences were less than 4%.

  6. Resonance Frequency of Optical Microbubble Resonators: Direct Measurements and Mitigation of Fluctuations

    Directory of Open Access Journals (Sweden)

    Alessandro Cosci

    2016-08-01

    Full Text Available This work shows the improvements in the sensing capabilities and precision of an Optical Microbubble Resonator due to the introduction of an encaging poly(methyl methacrylate (PMMA box. A frequency fluctuation parameter σ was defined as a score of resonance stability and was evaluated in the presence and absence of the encaging system and in the case of air- or water-filling of the cavity. Furthermore, the noise interference introduced by the peristaltic and the syringe pumping system was studied. The measurements showed a reduction of σ in the presence of the encaging PMMA box and when the syringe pump was used as flowing system.

  7. Electrothermal piezoresistive cantilever resonators for personal measurements of nanoparticles in workplace exposure

    Science.gov (United States)

    Wasisto, Hutomo Suryo; Wu, Wenze; Uhde, Erik; Waag, Andreas; Peiner, Erwin

    2015-05-01

    Low-cost and low-power piezoresistive cantilever resonators with integrated electrothermal heaters are developed to support the sensing module enhancement of the second generation of handheld cantilever-based airborne nanoparticle (NP) detector (CANTOR-2). These sensors are used for direct-reading of exposure to carbon engineered nanoparticles (ENPs) at indoor workplaces. The cantilever structures having various shapes of free ends are created using silicon bulk micromachining technologies (i.e, rectangular, hammer-head, triangular, and U-shaped cantilevers). For a complete wearable CANTOR-2, all components of the proposed detector can be grouped into two main units depending on their packaging placements (i.e., the NP sampler head and the electronics mounted in a handy-format housing). In the NP sampler head, a miniaturized electrophoretic aerosol sampler and a resonant silicon cantilever mass sensor are employed to collect the ENPs from the air stream to the cantilever surfaces and measuring their mass concentration, respectively. After calibration, the detected ENP mass concentrations of CANTOR-2 show a standard deviation from fast mobility particle sizer (FMPS, TSI 3091) of 8-14%.

  8. Non-integrability of first order resonances in Hamiltonian systems in three degrees of freedom

    Science.gov (United States)

    Christov, Ognyan

    2012-02-01

    The normal forms of the Hamiltonian 1:2: ω resonances to degree three for ω = 1, 3, 4 are studied for integrability. We prove that these systems are non-integrable except for the discrete values of the parameters which are well known. We use the Ziglin-Morales-Ramis method based on the differential Galois theory.

  9. Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Ludewigt, Bernhard A; Quiter, Brian J.; Ambers, Scott D.

    2011-01-14

    The Next Generation Safeguard Initiative (NGSI) of the U.S Department of Energy is supporting a multi-lab/university collaboration to quantify the plutonium (Pu) mass in spent nuclear fuel (SNF) assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. The following 14 NDA techniques are being studied: Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Lead Slowing Down Spectrometer, Neutron Multiplicity, Passive Neutron Albedo Reactivity, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Gamma, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Self-integration Neutron Resonance Densitometry, and Neutron Resonance Transmission Analysis. Understanding and maturity of the techniques vary greatly, ranging from decades old, well-understood methods to new approaches. Nuclear Resonance Fluorescence (NRF) is a technique that had not previously been studied for SNF assay or similar applications. Since NRF generates isotope-specific signals, the promise and appeal of the technique lies in its potential to directly measure the amount of a specific isotope in an SNF assay target. The objectives of this study were to design and model suitable NRF measurement methods, to quantify capabilities and corresponding instrumentation requirements, and to evaluate prospects and the potential of NRF for SNF assay. The main challenge of the technique is to achieve the sensitivity and precision, i.e., to accumulate sufficient counting statistics, required for quantifying the mass of Pu isotopes in SNF assemblies. Systematic errors, considered a lesser problem for a direct measurement and only briefly discussed in this report, need to be evaluated for specific instrument designs in the future. Also, since the technical capability of using NRF to measure Pu in SNF has not been established, this report does not directly address issues such as cost, size

  10. Multilevel resonance analysis of sup 59 Co neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    De Saussure, G.; Larson, N.M.; Harvey, J.A.; Hill, N.W. (Oak Ridge National Lab., TN (United States))

    1992-07-01

    Large discrepancies exist between the recent high-resolution neutron transmission data of {sup 59}Co measured at the Oak Ridge Electron Linear Accelerator (ORELA) and transmissions computed from the resolved resonance parameters of the nuclear data collection ENDF/B-VI. In order to provide new resonance parameters consistent with these data, the transmission measurements have been analyzed with the computer code SAMMY in the energy range 200 eV to 100 keV. The resonance parameters reported in this paper provide an accurate total cross section from 10{sup -5} eV to 100 keV and correctly reproduce the thermal capture cross section. Thermal cross-section values and related quantities are also reviewed here. (author).

  11. Inductive measurements of ferromagnetic resonance

    International Nuclear Information System (INIS)

    Woodward, R.C.; Kennewell, K.; Crew, D.C.; Stamps, R.L.

    2004-01-01

    Full text: The rapid advance in magnetic data storage has driven groundbreaking work in the science that underpins the properties of ferromagnetic materials at high frequencies. Recent work in this area has included the use of precession in order to produce ultra-high speed switching of magnetic elements, the generation of excited dynamical structures by application of inhomogeneous field pulses, and examination of the propagation of localized spin waves. This paper describes explorations of ultra-fast magnetization dynamics being undertaken at The University of Western Australia. We have studied the differences in magnetization dynamics in simple permalloy films when a sample is excited with sharp pulse compared to the to the dynamics generated by the application of a small amplitude continuous wave signal. We have observed a difference in the resonant frequency determined from these two excitations and will propose reasons for the different resonance responses of the system. Using the ultra-fast techniques described above we have measured dynamical properties that are significantly different to the static properties. These results are explained by the dynamical measurements being made on time scales smaller than the characteristic relaxation time. Future applications of these devices will be to examine broadening of line widths and frequency shifts associated with the excitation of magnetostatic modes, factors limiting quasiballistic reversal and differences between the dynamic and static properties of magnetic materials

  12. Ultrasonic series resonant converter with integrated L-C-T

    CSIR Research Space (South Africa)

    Smit, MC

    1995-01-01

    Full Text Available primary plate separation, w G bifilar primary 2EOE,NpW(h + To - T;) d C= where d plate width. Fig. 8. SPICE model of discrete component converter ~ 21 B. Spice Simulation The objective of the simulation is to show that the integrated structure... reacts in the same way as a discrete series inductor capacitor and transformer would do, and in turn agrees with the experimental results. Fig. 8 shows the SPICE circuit model of the discrete component series resonant converter. Inductance L...

  13. Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD

    Energy Technology Data Exchange (ETDEWEB)

    Trueman, C.W. [Concordia Univ., Montreal, Quebec (Canada); Mishra, S.R.; Larose, C.L. [David Florida Lab., Ottawa (Canada)] [and others

    1994-12-31

    This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

  14. Measurements and applications of neutron multiple scattering in resonance region

    International Nuclear Information System (INIS)

    Ohkubo, Makio

    1977-02-01

    Capture yield of neutrons impinging on a thick material is complicated due to self-shielding and multiple scattering, especially in the resonance region. When the incident neutron energy is equal to a resonance energy of the material, capture probability of the neutron increases with sample thickness and reaches a saturation value P sub(CO). There is a simple relation between P sub(CO) and GAMMA sub(n)/GAMMA and the recoil energy by the Monte-Carlo calculation. To examine validity of the relation, P sub(CO) was measured for 19 resonances in 12 nuclides with thick samples, using a JAERI linac time-of-flight spectrometer with Moxon-Rae type gamma ray detector and transmission type neutron flux monitor. Results of the measurements confirmed the validity. With this relation, the GAMMA sub(n)/GAMMA or GAMMA sub(γ)/GAMMA value can be obtained from the measured P sub(CO), and also the level spins be determined by combining the transmission data. Because of the definition of P sub(CO), determination of the resonance parameters is not sensitive to the sample thickness as far as it is sufficiently thick. (auth.)

  15. Longitudinal detection of ferromagnetic resonance using x-ray transmission measurements

    International Nuclear Information System (INIS)

    Boero, G.; Rusponi, S.; Kavich, J.; Rizzini, A. Lodi; Piamonteze, C.; Nolting, F.; Tieg, C.; Thiele, J.-U.; Gambardella, P.

    2009-01-01

    We describe a setup for the x-ray detection of ferromagnetic resonance in the longitudinal geometry using element-specific transmission measurements. Thin magnetic film samples are placed in a static magnetic field collinear with the propagation direction of a polarized soft x-ray beam and driven to ferromagnetic resonance by a continuous wave microwave magnetic field perpendicular to it. The transmitted photon flux is measured both as a function of the x-ray photon energy and as a function of the applied static magnetic field. We report experiments performed on a 15 nm film of doped Permalloy (Ni 73 Fe 18 Gd 7 Co 2 ) at the L 3 /L 2 -edges of Fe, Co, and Ni. The achieved ferromagnetic resonance sensitivity is about 0.1 monolayers/√(Hz). The obtained results are interpreted in the framework of a conductivity tensor based formalism. The factors limiting the sensitivity as well as different approaches for the x-ray detection of ferromagnetic resonance are discussed.

  16. Magnetically integrated high step-up resonant DC-DC converter for distributed photovoltaic systems

    DEFF Research Database (Denmark)

    Vinnikov, Dmitri; Chub, Andrii; Liivik, Elizaveta

    2017-01-01

    In this paper magnetically integrated resonant single-switch quasi-Z-source DC-DC converter is evaluated as a candidate topology for the low-cost photovoltaic microconverter. The derivation of the topology and its basic operation principle are explained. Generalized design guidelines...

  17. Measurement of the resonance escape probability; Mesure de l'absorption resonnante

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, J P; Bacher, P; Lheureux, L; Moreau, J; Schmitt, A P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The average cadmium ratio in natural uranium rods has been measured, using equal diameter natural uranium disks. These values correlated with independent measurements of the lattice buckling, enabled us to calculate values of the resonance escape probability for the G1 reactor with one or the other of two definitions. Measurements were performed on 26 mm and 32 mm rods, giving the following values for the resonance escape probability p: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). The influence of either definition on the lattice parameters is discussed, leading to values of the effective integral. Similar experiments have been performed with thorium rods. (author) [French] Nous avons mesure le rapport cadmium moyen dans des barres d'uranium a l'aide de disques d'uranium naturel de meme diametre que ces dernieres. Ces mesures nous ont permis, conjointement avec des mesures de Laplacien du reseau, de determiner deux facteurs antitrappes du reacteur G1 correspondant a deux definitions exposees. Les mesures ont ete faites sur deux diametres de barres 26 et 32 mm. Resultats: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). L'influence de ces deux definitions sur les divers parametres du reseau, est discutee. La determination de 'p' pour un diametre de barres d'uranium de 26 mm, et les mesures de variation de Laplacien, nous ont permis de calculer une valeur de l'integrale effective correspondant a chaque definition. Les mesures analogues faites sur des barres de thorium sont egalement indiquees. (auteur)

  18. Measuring Restriction Sizes Using Diffusion Weighted Magnetic Resonance Imaging: A Review

    Directory of Open Access Journals (Sweden)

    Melanie Martin

    2013-01-01

    Full Text Available This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE measurements could provide shorter diffusion times so smaller restriction sizes could be probed.

  19. Resonance control of mid-infrared metamaterials using arrays of split-ring resonator pairs

    KAUST Repository

    Yue, Weisheng

    2016-01-11

    We present our design, fabrication and characterization of resonance-controllable metamaterials operating at mid-infrared wavelengths. The metamaterials are composed of pairs of back-to-back or face-to-face U-shape split-ring resonators (SRRs). Transmission spectra of the metamaterials are measured using Fourier-transform infrared spectroscopy. The results show that the transmission resonance is dependent on the distance between the two SRRs in each SRR pair. The dips in the transmission spectrum shift to shorter wavelengths with increasing distance between the two SRRs for both the back-to-back and face-to-face SRR pairs. The position of the resonance dips in the spectrum can hence be controlled by the relative position of the SRRs. This mechanism of resonance control offers a promising way of developing metamaterials with tunability for optical filters and bio/chemical sensing devices in integrated nano-optics.

  20. Resonance control of mid-infrared metamaterials using arrays of split-ring resonator pairs

    KAUST Repository

    Yue, Weisheng; Wang, Zhihong; Whittaker, John; Schedin, Fredrik; Wu, Zhipeng; Han, Jiaguang

    2016-01-01

    We present our design, fabrication and characterization of resonance-controllable metamaterials operating at mid-infrared wavelengths. The metamaterials are composed of pairs of back-to-back or face-to-face U-shape split-ring resonators (SRRs). Transmission spectra of the metamaterials are measured using Fourier-transform infrared spectroscopy. The results show that the transmission resonance is dependent on the distance between the two SRRs in each SRR pair. The dips in the transmission spectrum shift to shorter wavelengths with increasing distance between the two SRRs for both the back-to-back and face-to-face SRR pairs. The position of the resonance dips in the spectrum can hence be controlled by the relative position of the SRRs. This mechanism of resonance control offers a promising way of developing metamaterials with tunability for optical filters and bio/chemical sensing devices in integrated nano-optics.

  1. Techniques and processes for the measurement of the resonances of small single crystals

    International Nuclear Information System (INIS)

    Migliori, A.; Stekel, A.; Sarrao, J.L.; Visscher, W.M.; Bell, T.; Lei, M.

    1991-01-01

    The mechanical resonances of small oriented single crystals of materials of interest to basic science and engineering can be used to determine all the elastic moduli and the ultrasonic attenuation of these materials. To measure the resonances of the samples without introducing the resonances of the measuring system requires that the transducers be non-resonant at the frequencies of interest, and that they be well isolated from their mounts. However, for samples near 1 mm in the largest dimension, the transducer design problem becomes sever, and the signals become weak. In addition, no resonances can be missed, and, often, the symmetry class of the resonances must be known. We outline here appropriate transducer, electronics, and system designs to circumvent these problems. 10 refs., 4 figs

  2. Experimental determination of resonance absorption cross sections for Zircaloy-2 and zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Kocic, A; Markovic, V [Boris Kidric Institute of Nuclear Sciences, Vinca, Beograd (Yugoslavia)

    1968-05-15

    The integral absorption cross section for the neutron spectrum and the thermal absorption cross section for zircaloy-2 have been determined using the pile oscillator technique. Using both values and a measured ratio of the epithermal to the thermal flux, the effective resonance integrals were obtained. After subtraction of the contributions for alloy and impurity elements, the effective resonance integrals for zirconium were evaluated. An extrapolated value of 0.91{+-}0.10 was obtained for the dilute integral. (author)

  3. Quality measurements of resonance cavities in behalf of investigation of microwave properties of superconducting materials

    International Nuclear Information System (INIS)

    Dekkers, G.; Ridder, M. de.

    1988-01-01

    A method for investigating conducting properties at microwave frequencies of superconducting materials by means of quality measurements of a resonance cavity is described. The method is based on the direct relationship of the quality factor of a resonance circuit, in this case a resonance cavity, with the losses in the circuit. In a resonance cavity these losses are caused by the material properties of the resonance cavity. Therefore quality measurements yield, essentially, a possibility for investigation of conducting properties of materials. The underlying theory of the subject, the design of a special resonance cavity, the measuring methods and the accuracy in the relation of the measured quality factor and the specific conductivity of the material is presented. refs.; figs.; tabs

  4. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research. A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones. This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties. We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care integration (33%) and patient

  5. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research.A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones.This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties.We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Context Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Methods Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. Findings From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care

  6. A Determination of the 2200 m/s Absorption Cross Section and Resonance Integral of Arsenic by Pile Oscillator Technique

    Energy Technology Data Exchange (ETDEWEB)

    Sokolowski, E K; Bladh, R

    1969-02-15

    Pile oscillator measurements of heavy-water solutions of As, B, Mn and In have been carried out in two different neutron spectra in the R0 reactor. For B, Mn and In the 2200 m/s cross section values recommended in BNL-325 are given to within 1.5 % or less, while for As the stated uncertainty is 5 %. In the present work the BNL values for B, Mn and In were used to derive weighted mean calibration constants for the reactor, which were then in turn used for obtaining self-consistent cross section values for all four elements. The values thus obtained for B, Mn and In were within experimental error of the recommended BNL values. The absorption cross section for As is in good agreement with a recently published value for the activation cross section. The value for the resonance integral of As, derived from the present measurements, is in better agreement with calculations from resonance parameters than values reported earlier.

  7. A Determination of the 2200 m/s Absorption Cross Section and Resonance Integral of Arsenic by Pile Oscillator Technique

    International Nuclear Information System (INIS)

    Sokolowski, E.K.; Bladh, R.

    1969-02-01

    Pile oscillator measurements of heavy-water solutions of As, B, Mn and In have been carried out in two different neutron spectra in the R0 reactor. For B, Mn and In the 2200 m/s cross section values recommended in BNL-325 are given to within 1.5 % or less, while for As the stated uncertainty is 5 %. In the present work the BNL values for B, Mn and In were used to derive weighted mean calibration constants for the reactor, which were then in turn used for obtaining self-consistent cross section values for all four elements. The values thus obtained for B, Mn and In were within experimental error of the recommended BNL values. The absorption cross section for As is in good agreement with a recently published value for the activation cross section. The value for the resonance integral of As, derived from the present measurements, is in better agreement with calculations from resonance parameters than values reported earlier

  8. The feasibility study of Dragon Ⅰ using for temperature measurement of resonance neutron

    International Nuclear Information System (INIS)

    Xiang Yanjun; Ma Jingfang; Ai Jie; Fan Ruifeng

    2010-01-01

    The temperature measurement using neutron resonance spectrum can be used for temperature measurement of shock wave, but the high intensity pulsed neutron source is needed. This paper calculates the neutron transmission spectrum through resonance sample (contained 182 W), which produced by the current electron beam of Dragon Ⅰ impacting uranium target. The 4.155 eV and 21.06 eV resonance drop of 182 W can be seen from the transmission spectrum. Then, according to the experiment condition of Los Alamos, the neutron resonance spectrum of Dragon Ⅰ have been computed. Dragon Ⅰ can be used for temperature measurement using neutron spectrum, comparing this simulated result and the experiment result of Los Alamos. (authors)

  9. Energy measurement using a resonator based time-of-flight system

    International Nuclear Information System (INIS)

    Pardo, R.C.; Clifft, B.; Johnson, K.W.; Lewis, R.N.

    1983-01-01

    A resonant pick-up time-of-flight system has been developed for the precise measurement of beam energy at the Argonne Tandem-Linac Accelerator System (ATLAS). The excellent timing characteristics available with ATLAS beams make it desirable to design the beam transport system to be isochronous. The advantages of the resonant time-of-flight system over other energy analysis systems such as the dispersive magnet system are numerous. The system is non-interceptive and non-destructive and preserves the beam phase space. It is non-dispersive. Path length variations are not introduced into the beam which would reduce the timing resolution. It has a large signal-to-noise ratio when compared to non-resonant beam pick-up techniques. It provides the means to precisely set the linac energy and potentially to control the energy in a feedback loop. Finally, the resonant pick-up time-of-flight system is less expensive than an equivalent magnetic system. It consists of two beam-excited resonators, associated electronics to decode the information, a computer interface to the linac PDP 11/34 control computer, and software to analyze the information and deduce the measured beam energy. This report describes the system and its components and gives a schematic overview

  10. Isotopic Resonance Hypothesis: Experimental Verification by Escherichia coli Growth Measurements

    Science.gov (United States)

    Xie, Xueshu; Zubarev, Roman A.

    2015-03-01

    Isotopic composition of reactants affects the rates of chemical and biochemical reactions. As a rule, enrichment of heavy stable isotopes leads to progressively slower reactions. But the recent isotopic resonance hypothesis suggests that the dependence of the reaction rate upon the enrichment degree is not monotonous. Instead, at some ``resonance'' isotopic compositions, the kinetics increases, while at ``off-resonance'' compositions the same reactions progress slower. To test the predictions of this hypothesis for the elements C, H, N and O, we designed a precise (standard error +/-0.05%) experiment that measures the parameters of bacterial growth in minimal media with varying isotopic composition. A number of predicted resonance conditions were tested, with significant enhancements in kinetics discovered at these conditions. The combined statistics extremely strongly supports the validity of the isotopic resonance phenomenon (p biotechnology, medicine, chemistry and other areas.

  11. Measuring integrated care.

    Science.gov (United States)

    Strandberg-Larsen, Martin

    2011-02-01

    The positive outcomes of coordination of healthcare services are to an increasing extent becoming clear. However the complexity of the field is an inhibiting factor for vigorously designed trial studies. Conceptual clarity and a consistent theoretical frame-work are thus needed. While researchers respond to these needs, patients and providers face the multiple challenges of today's healthcare environment. Decision makers, planners and managers need evidence based policy options and information on the scope of the integrated care challenges they are facing. The US managed care organization Kaiser Permanente has been put forward as an example for European healthcare systems to follow, although the evidence base is far from conclusive. The thesis has five objectives: 1) To contribute to the understanding of the concept of integration in healthcare systems and to identify measurement methods to capture the multi-dimensional aspects of integrated healthcare delivery. 2) To assess the level of integration of the Danish healthcare system. 3) To assess the use of joint health plans as a tool for coordination between the regional and local level in the Danish healthcare system. 4) To compare the inputs and performance of the Danish healthcare system and the managed care organization Kaiser Permanente, California, US. 5) To compare primary care clinicians' perception of clinical integration in two healthcare systems: Kaiser Permanente, Northern California and the Danish healthcare system. Further to examine the associations between specific organizational factors and clinical integration within each system. The literature was systematically searched to identify methods for measurement of integrated healthcare delivery. A national cross-sectional survey was conducted among major professional stake-holders at five different levels of the Danish healthcare system. The survey data were used to allow for analysis of the level of integration achieved. Data from the survey were

  12. Qubit Coupled Mechanical Resonator in an Electromechanical System

    Science.gov (United States)

    Hao, Yu

    This thesis describes the development of a hybrid quantum electromechanical system. In this system the mechanical resonator is capacitively coupled to a superconducting transmon which is embedded in a superconducting coplanar waveguide (CPW) cavity. The difficulty of achieving high quality of superconducting qubit in a high-quality voltage-biased cavity is overcome by integrating a superconducting reflective T-filter to the cavity. Further spectroscopic and pulsed measurements of the hybrid system demonstrate interactions between the ultra-high frequency mechanical resonator and transmon qubit. The noise of mechanical resonator close to ground state is measured by looking at the spectroscopy of the transmon. At last, fabrication and tests of membrane resonators are discussed.

  13. Quantum measure and integration theory

    International Nuclear Information System (INIS)

    Gudder, Stan

    2009-01-01

    This article begins with a review of quantum measure spaces. Quantum forms and indefinite inner-product spaces are then discussed. The main part of the paper introduces a quantum integral and derives some of its properties. The quantum integral's form for simple functions is characterized and it is shown that the quantum integral generalizes the Lebesgue integral. A bounded, monotone convergence theorem for quantum integrals is obtained and it is shown that a Radon-Nikodym-type theorem does not hold for quantum measures. As an example, a quantum-Lebesgue integral on the real line is considered.

  14. RESONANT BPM FOR CONTINUOUS TUNE MEASUREMENT IN RHIC

    International Nuclear Information System (INIS)

    KESSELMAN, M.; CAMERON, P.; CUPOLO, J.

    2001-01-01

    A movable Beam Position Monitor (BPM) using shorted stripline Pick-Up Electrode (NE) elements has been resonated using matching stub techniques to achieve a relatively high Q resonance at about 230MHz. This PUE has been used in a feasibility study of phase-locked-loop tune measurement [1], using a lock-in amplifier and variable frequency generator to continuously track betatron tune in RHIC, as well as to observe Schottky signals of the Gold beam. The approach to providing a high Q PUE for difference mode signals, simulation studies, and the results of initial tests will be presented

  15. Measuring the degree of integration for an integrated service network

    Directory of Open Access Journals (Sweden)

    Chenglin Ye

    2012-09-01

    Full Text Available Background: Integration involves the coordination of services provided by autonomous agencies and improves the organization and delivery of multiple services for target patients. Current measures generally do not distinguish between agencies' perception and expectation. We propose a method for quantifying the agencies' service integration. Using the data from the Children's Treatment Network (CTN, we aimed to measure the degree of integration for the CTN agencies in York and Simcoe.  Theory and Methods: We quantified the integration by the agreement between perceived and expected levels of involvement and calculated four scores from different perspectives for each agency. We used the average score to measure the global network integration and examined the sensitivity of the global score.  Results: Most agencies' integration scores were less than 65%. As measured by the agreement between every other agency's perception and expectation, the overall integration of CTN in Simcoe and York was 44% (95% CI: 39% - 49% and 52% (95% CI: 48% - 56%, respectively. The sensitivity analysis showed that the global scores were robust.  Conclusion: Our method extends existing measures of integration and possesses a good extent of validity. We can also apply the method in monitoring improvement and linking integration with other outcomes.

  16. Measuring the degree of integration for an integrated service network

    Directory of Open Access Journals (Sweden)

    Chenglin Ye

    2012-09-01

    Full Text Available Background: Integration involves the coordination of services provided by autonomous agencies and improves the organization and delivery of multiple services for target patients. Current measures generally do not distinguish between agencies' perception and expectation. We propose a method for quantifying the agencies' service integration. Using the data from the Children's Treatment Network (CTN, we aimed to measure the degree of integration for the CTN agencies in York and Simcoe. Theory and Methods: We quantified the integration by the agreement between perceived and expected levels of involvement and calculated four scores from different perspectives for each agency. We used the average score to measure the global network integration and examined the sensitivity of the global score. Results: Most agencies' integration scores were less than 65%. As measured by the agreement between every other agency's perception and expectation, the overall integration of CTN in Simcoe and York was 44% (95% CI: 39% - 49% and 52% (95% CI: 48% - 56%, respectively. The sensitivity analysis showed that the global scores were robust. Conclusion: Our method extends existing measures of integration and possesses a good extent of validity. We can also apply the method in monitoring improvement and linking integration with other outcomes. 

  17. Non-additive measure and integral

    CERN Document Server

    Denneberg, Dieter

    1994-01-01

    Non-Additive Measure and Integral is the first systematic approach to the subject. Much of the additive theory (convergence theorems, Lebesgue spaces, representation theorems) is generalized, at least for submodular measures which are characterized by having a subadditive integral. The theory is of interest for applications to economic decision theory (decisions under risk and uncertainty), to statistics (including belief functions, fuzzy measures) to cooperative game theory, artificial intelligence, insurance, etc. Non-Additive Measure and Integral collects the results of scattered and often isolated approaches to non-additive measures and their integrals which originate in pure mathematics, potential theory, statistics, game theory, economic decision theory and other fields of application. It unifies, simplifies and generalizes known results and supplements the theory with new results, thus providing a sound basis for applications and further research in this growing field of increasing interest. It also co...

  18. Overtones of isoscalar giant resonances studied in direct particle decay measurements

    NARCIS (Netherlands)

    Hunyadi, M; van den Berg, AM; Csatlos, M; Csige, L; Davids, B; Garg, U; Gulyas, J; Harakeh, MN; de Huu, MA; Krasznahorkay, A; Sohler, D; Wortche, HJ

    The isoscalar giant dipole resonance (ISGDR), which is the lowest-energy overtone mode of the isoscalar giant resonances, has been studied in some medium-heavy and heavy nuclei in coincidence measurements. The observation of the direct nucleon decay channels significantly helped to enhance giant

  19. Measurement of pressure on a surface using bubble acoustic resonances

    International Nuclear Information System (INIS)

    Aldham, Ben; Manasseh, Richard; Liffman, Kurt; Šutalo, Ilija D; Illesinghe, Suhith; Ooi, Andrew

    2010-01-01

    The frequency response of gas bubbles as a function of liquid ambient pressure was measured and compared with theory. A bubble size with equivalent spherical radius of 2.29 mm was used over a frequency range of 1000–1500 Hz. The ultimate aim is to develop an acoustic sensor that can measure static pressure and is sensitive to variations as small as a few kPa. The classical bubble resonance frequency is known to vary with ambient pressure. Experiments were conducted with a driven bubble in a pressurizable tank with a signal processing system designed to extract the resonant peak. Since the background response of the containing tank is significant, particularly near tank-modal resonances, it must be carefully removed from the bubble response signal. A dual-hydrophone method was developed to allow rapid and reliable real-time measurements. The expected pressure dependence was found. In order to obtain a reasonable match with theory, the classical theory was modified by the introduction of a 'mirror bubble' to account for the influence of a nearby surface. (technical design note)

  20. Photonic crystal ring resonator based optical filters for photonic integrated circuits

    International Nuclear Information System (INIS)

    Robinson, S.

    2014-01-01

    In this paper, a two Dimensional (2D) Photonic Crystal Ring Resonator (PCRR) based optical Filters namely Add Drop Filter, Bandpass Filter, and Bandstop Filter are designed for Photonic Integrated Circuits (PICs). The normalized output response of the filters is obtained using 2D Finite Difference Time Domain (FDTD) method and the band diagram of periodic and non-periodic structure is attained by Plane Wave Expansion (PWE) method. The size of the device is minimized from a scale of few tens of millimeters to the order of micrometers. The overall size of the filters is around 11.4 μm × 11.4 μm which is highly suitable of photonic integrated circuits

  1. Micro-resonators based on integrated polymer technology for optical sensing

    Science.gov (United States)

    Girault, Pauline; Lemaitre, Jonathan; Guendouz, Mohammed; Lorrain, Nathalie; Poffo, Luiz; Gadonna, Michel; Bosc, Dominique

    2014-05-01

    Research on sensors has experienced a noticeable development over the last decades especially in label free optical biosensors. However, compact sensors without markers for rapid, reliable and inexpensive detection of various substances induce a significant research of new technological solutions. The context of this work is the development of a sensor based on easily integrated and inexpensive micro-resonator (MR) component in integrated optics, highly sensitive and selective mainly in the areas of health and food. In this work, we take advantage of our previous studies on filters based on micro-resonators (MR) to experiment a new couple of polymers in the objective to use MR as a sensing function. MRs have been fabricated by processing SU8 polymer as core and PMATRIFE polymer as cladding layer of the waveguide. The refractive index contrast reaches 0.16 @ 1550 nm. Sub-micronic ring waveguides gaps from 0.5 to 1 μm have been successfully achieved with UV (i-line) photolithography. This work confirms our forecasts, published earlier, about the resolution that can be achieved. First results show a good extinction coefficient of ~17 dB, a quality factor around 104 and a finesse of 12. These results are in concordance with the theoretical study and they allow us to validate our technology with this couple of polymers. Work is going on with others lower cladding materials that will be used to further increase refractive index contrast for sensing applications.

  2. Measurements of resonance frequencies on prestressed concrete beams during post-tensioning

    International Nuclear Information System (INIS)

    Lundqvist, P.; Ryden, N.

    2011-01-01

    The reactor containment, which is a concrete structure prestressed vertically and horizontally, is the most essential safety barrier in a nuclear power plant and is designed to withstand a severe internal accident. The safety of the containment depends on the induced compressive stresses in the concrete, however due to various long-term mechanisms the tendon forces will decrease with time. Today, no methods exist for measuring these prestress losses in containments with bonded tendons and thus there is a need for non-destructive methods for estimating the losses in these structures. Recent results from non-linear ultrasonic measurements during uniaxial loading have demonstrated a strong acoustic and elastic effect in concrete. The present research applies resonant acoustic spectroscopy (RAS) during static loading and unloading of three prestressed concrete beams. At each load step multiple modes of vibration are measured using an accelerometer and a small impact source. Measured resonant frequencies increase with increasing compressive stress. The stress dependency of the modulus of elasticity indicates that the change in state of stress in a simple concrete structure can be estimated by simply measuring the resonance frequency

  3. Resonant passive–active vibration absorber with integrated force feedback control

    International Nuclear Information System (INIS)

    Høgsberg, Jan; Brodersen, Mark L; Krenk, Steen

    2016-01-01

    A general format of a two-terminal vibration absorber is constructed by placing a passive unit in series with a hybrid unit, composed of an active actuator in parallel with a second passive element. The displacement of the active actuator is controlled by an integrated feedback control with the difference in force between the two passive elements as input. This format allows passive and active contributions to be combined arbitrarily within the hybrid unit, which results in a versatile absorber format with guaranteed closed-loop stability. This is demonstrated for resonant absorbers with inertia realized passively by a mechanical inerter or actively by the integrated force feedback. Accurate calibration formulae are presented for two particular absorber configurations and the performance is subsequently demonstrated with respect to both equal modal damping and effective response reduction. (technical note)

  4. A resonant absorption measurement in the reaction 26Mg(p, γ)27Al

    NARCIS (Netherlands)

    Leun, C. van der; Burhoven Jaspers, N.C.

    1966-01-01

    A resonant absorption measurement at the 1966 keV proton resonance in the reaction 26Mg(p, γ)27Al leads to an absolute determination of the resonance strength, (2J+1)ΓpΓγ/Γ, of 5.6±1.8 eV. Normalization of previously published strengths of 120 resonances in the reaction 26Mg(p, γ)27Al, reduces these

  5. A warning on fission resonance intergrals: Caveat utor

    International Nuclear Information System (INIS)

    Holden, N.E.

    1988-01-01

    A common error is made in defining the resonance integral in most tabulations and handbooks. Although it has a minor effect on the capture resonance integral and on the fission resonance integral for the fissile nuclides, it leads to gross errors in the fission resonance integral for the fertile nuclides. The errors in the fission resonance integral for fertile nuclides of the elements from thorium through curium in the ENDF/B-V library will be presented. Let the user beware

  6. Integrated test plan ResonantSonic drilling system technology demonstration-1995, at the Hanford Site: Revision 1

    International Nuclear Information System (INIS)

    McLellan, G.W.

    1994-01-01

    This integrated test plan describes the demonstration test of the ResonantSonic drilling system. This demonstration is part of the Office of Technology Development's Volatile Organic Compound Arid Integrated Demonstration (VOC-Arid ID). Two main purposes of this demonstration are (1) to continue testing the ResonantSonic drilling system compatibility with the Hanford Site waste characterization programs, and (2) to transfer this method for use at the Hanford Site, other government sites, and the private sector. The ResonantSonic method is a dry drilling technique. Field testing of this method began in July 1993. During the next four months, nine holes were drilled, and continuous core samples were retrieved. Penetration rates were 2 to 3 times the baseline, and the operational downtime rate was less than 10%. Successfully demonstrated equipment refinements included a prototype 300 series ResonantSonic head, a new drill rod design for 18-centimeter diameter pipe, and an automated pipe handling system. Various configurations of sampling equipment and drill bits were tested, depending on geologic conditions. The principal objective of the VOC-Arid ID is to determine the viability of emerging technologies that can be used to characterize, remediate, and/or monitor arid or semiarid sites containing VOCs (e.g., carbon tetrachloride) with or without associated metal and radionuclide contamination

  7. Set up of a method for the adjustment of resonance parameters on integral experiments; Mise au point d`une methode d`ajustement des parametres de resonance sur des experiences integrales

    Energy Technology Data Exchange (ETDEWEB)

    Blaise, P.

    1996-12-18

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.).

  8. Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium

    International Nuclear Information System (INIS)

    NJ Drindak; JA Burke; G Leinweber; JA Helm; JG Hoole; RC Block; Y Danon; RE Slovacek; BE Moretti; CJ Werner; ME Overberg; SA Kolda; MJ Trbovich; DP Barry

    2005-01-01

    Epithermal neutron capture and transmission measurements were performed using the time-of-flight method at the RPI linac using metallic Nb samples. The capture measurements were made at the 25-meter flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-meter flight station with a Li-6 glass scintillation detector. Resonance parameters were determined for all resonances up to 500eV with a combined analysis of capture and transmission data using the multi-level R-matrix Bayesian code SAMMY. The present results are compared to those presented in ENDF/B-VI, updated through Release 3

  9. Amotivation in schizophrenia: integrated assessment with behavioral, clinical, and imaging measures.

    Science.gov (United States)

    Wolf, Daniel H; Satterthwaite, Theodore D; Kantrowitz, Jacob J; Katchmar, Natalie; Vandekar, Lillie; Elliott, Mark A; Ruparel, Kosha

    2014-11-01

    Motivational deficits play a central role in disability caused by schizophrenia and constitute a major unmet therapeutic need. Negative symptoms have previously been linked to hypofunction in ventral striatum (VS), a core component of brain motivation circuitry. However, it remains unclear to what extent this relationship holds for specific negative symptoms such as amotivation, and this question has not been addressed with integrated behavioral, clinical, and imaging measures. Here, 41 individuals with schizophrenia and 37 controls performed a brief, computerized progressive ratio task (PRT) that quantifies effort exerted in pursuit of monetary reward. Clinical amotivation was assessed using the recently validated Clinical Assessment Interview for Negative Symptoms (CAINS). VS function was probed during functional magnetic resonance imaging using a monetary guessing paradigm. We found that individuals with schizophrenia had diminished motivation as measured by the PRT, which significantly and selectively related to clinical amotivation as measured by the CAINS. Critically, lower PRT motivation in schizophrenia was also dimensionally related to VS hypofunction. Our results demonstrate robust dimensional associations between behavioral amotivation, clinical amotivation, and VS hypofunction in schizophrenia. Integrating behavioral measures such as the PRT will facilitate translational efforts to identify biomarkers of amotivation and to assess response to novel therapeutic interventions. © The Author 2014. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  10. Measurements of the anomalous RF surface resistance of niobium using a dielectric resonator

    International Nuclear Information System (INIS)

    Moffat, D.; Bolore, M.; Bonin, B.; Jacques, E.; Safa, H.

    1996-01-01

    The surface resistance of high and low residual resistance ratio (RRR) niobium plates at 4.2 K and 1.8 K has been measured as a function of many processing and testing parameters. A dielectric resonator was used instead of a resonant cavity. This resonator offered the ability to make many, sensitive measurements with an efficient use of time and helium. It was found that the surface resistance, R s , of RRR = 190 niobium increased noticeably from the theoretical value if the cooling rate was slower than ∼ 10 K/min. (author)

  11. Measurement of thermal neutron cross-sections and resonance integrals for sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As by using sup 2 sup 4 sup 1 Am-Be isotopic neutron source

    CERN Document Server

    Karadag, M; Tan, M; Oezmen, A

    2003-01-01

    Thermal neutron cross-sections and resonance integrals for the sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As reactions were measured by the activation method. The experimental samples with and without a cylindrical Cd shield case in 1 mm wall thickness were irradiated in an isotropic neutron field of the sup 2 sup 4 sup 1 Am-Be neutron source. The induced activities in the samples were measured by high-resolution gamma-ray spectrometry with a calibrated reverse-electrode germanium detector. Thermal neutron cross-sections for 2200 m/s neutrons and resonance integrals for the sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As reactions have been obtained relative to the reference values, sigma sub 0 =13.3+-0.1 b and I sub 0 =14.0+-0.3 b for the sup 5 sup 5 Mn(n,gamma) sup 5 sup 6 Mn reaction as a single comparator. The necessary correction factors for gamma attenuation, thermal neutron and resonance neutron self-shielding effects were taken into...

  12. Towards measuring the off-resonant thermal noise of a pendulum mirror

    CERN Document Server

    Leonhardt, V; Kloevekorn, P; Willke, B; Lück, H B; Danzmann, K

    2002-01-01

    Thermal noise is one of the dominant noise sources in interferometric length measurements and can limit the sensitivity of gravitational wave detectors. Our goal is to analyse the off-resonant thermal noise of a high Q pendulum. Therefore we interferometrically detect the length changes of a 2.3 cm long optical resonator, which for good seismic isolation consists of two multiple stage pendulums. We are able to lock the length of this optical resonator to a frequency-stabilized laser beam and as a result get the spectral density of the differential mirror movement.

  13. Resonator coupled Josephson junctions; parametric excitations and mutual locking

    DEFF Research Database (Denmark)

    Jensen, H. Dalsgaard; Larsen, A.; Mygind, Jesper

    1991-01-01

    Self-pumped parametric excitations and mutual locking in systems of Josephson tunnel junctions coupled to multimode resonators are reported. For the very large values of the coupling parameter, obtained with small Nb-Al2O3-Nb junctions integrated in superconducting microstrip resonators, the DC I......-V characteristic shows an equidistant series of current steps generated by subharmonic pumping of the fundamental resonator mode. This is confirmed by measurement of frequency and linewidth of the emitted Josephson radiation...

  14. Measurements of time average series resonance effect in capacitively coupled radio frequency discharge plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Favre, M.; Wyndham, E.; Chuaqui, H.; Kakati, M.

    2011-01-01

    Self-excited plasma series resonance is observed in low pressure capacitvely coupled radio frequency discharges as high-frequency oscillations superimposed on the normal radio frequency current. This high-frequency contribution to the radio frequency current is generated by a series resonance between the capacitive sheath and the inductive and resistive bulk plasma. In this report, we present an experimental method to measure the plasma series resonance in a capacitively coupled radio frequency argon plasma by modifying the homogeneous discharge model. The homogeneous discharge model is modified by introducing a correction factor to the plasma resistance. Plasma parameters are also calculated by considering the plasma series resonances effect. Experimental measurements show that the self-excitation of the plasma series resonance, which arises in capacitive discharge due to the nonlinear interaction of plasma bulk and sheath, significantly enhances both the Ohmic and stochastic heating. The experimentally measured total dissipation, which is the sum of the Ohmic and stochastic heating, is found to increase significantly with decreasing pressure.

  15. Measuring integrated care

    DEFF Research Database (Denmark)

    Strandberg-Larsen, Martin

    2011-01-01

    respond to these needs, patients and providers face the multiple challenges of today's healthcare environment. Decision makers, planners and managers need evidence based policy options and information on the scope of the integrated care challenges they are facing. The US managed care organization Kaiser...... differences were found in the perception of clinical integration in the two settings. More primary care clinicians in the Northern California region of Kaiser Permanente reported being part of a clinical integrated environment than did Danish general practitioners. By measuring the level of clinical...... and performance of the Danish healthcare system and the managed care organization Kaiser Permanente, California, US. 5) To compare primary care clinicians' perception of clinical integration in two healthcare systems: Kaiser Permanente, Northern California and the Danish healthcare system. Further to examine...

  16. First measurement of isoscalar giant resonances in a stored-beam experiment

    Directory of Open Access Journals (Sweden)

    J.C. Zamora

    2016-12-01

    Full Text Available A new technique developed for measuring nuclear reactions at low momentum transfer with stored beams in inverse kinematics was successfully used to study isoscalar giant resonances. The experiment was carried out at the experimental heavy-ion storage ring (ESR at the GSI facility using a stored 58Ni beam at 100 MeV/u and an internal helium gas-jet target. In these measurements, inelastically scattered α-recoils at very forward center-of-mass angles (θcm≤1.5° were detected with a dedicated setup, including ultra-high vacuum compatible detectors. Experimental results indicate a dominant contribution of the isoscalar giant monopole resonance at this very forward angular range. It was found that the monopole contribution exhausts 79−11+12% of the energy-weighted sum rule (EWSR, which agrees with measurements performed in normal kinematics. This opens up the opportunity to investigate the giant resonances in a large domain of unstable and exotic nuclei in the near future. It is a fundamental milestone towards new nuclear reaction studies with stored ion beams.

  17. Monolithic integration of a resonant tunneling diode and a quantum well semiconductor laser

    Science.gov (United States)

    Grave, I.; Kan, S. C.; Griffel, G.; Wu, S. W.; Sa'Ar, A.

    1991-01-01

    A monolithic integration of a double barrier AlAs/GaAs resonant tunneling diode and a GaAs/AlGaAs quantum well laser is reported. Negative differential resistance and negative differential optical response are observed at room temperature. The device displays bistable electrical and optical characteristics which are voltage controlled. Operation as a two-state optical memory is demonstrated.

  18. Highly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators

    Directory of Open Access Journals (Sweden)

    Oscar Malvar

    2015-03-01

    Full Text Available We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for liquid binary mixtures of ethanol in water, glycerol in water and Triton in ethanol. The method achieves a detection limit in an air environment of 50 µg/mL that is only five times higher than that obtained with state-of-the-art suspended microchannel resonators encapsulated in vacuum. The method opens the door to novel advances for miniaturized total analysis systems based on microcapillaries with the add-on of mechanical transduction for sensing the rheological properties of the analyzed fluids without the need for vacuum encapsulation of the resonators.

  19. Ultra-Precise Measurement of Distance by Fabry-Perot Resonator

    Czech Academy of Sciences Publication Activity Database

    Číp, Ondřej; Petrů, František; Lazar, Josef; Buchta, Zdeněk

    T118, - (2005), s. 45-47 ISSN 0031-8949 R&D Projects: GA ČR(CZ) GP102/02/P122 Keywords : length measurements * laser interferometer * optical resonator Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  20. Calculation of resonance integral for fuel cluster

    International Nuclear Information System (INIS)

    Remsak, S.

    1969-01-01

    The procedure for calculating the shielding correction, formulated in the previous paper [6], was broadened and applied for a cluster of cylindrical rods. The sam analytical method as in the previous paper was applied. A combination of Gauss method with the method of Almgren and Porn used for solving the same type of integral was used to calculate the geometry functions. CLUSTER code was written for ZUSE-Z-23 computer to calculate the shielding corrections for pairs of fuel rods in the cluster. Computing time for one pair of fuel rods depends on the number of closely placed rod, and for two closely placed rods it is about 3 hours. Calculations were done for clusters containing 7 and 19 UO 2 rods. results show that calculated values of resonance integrals are somewhat higher than the values obtained by Helstrand empirical formula. Taking into account the results for two rods from the previous paper it can be noted that the calculated and empirical values for clusters with 2 and 7 rods are in agreement since the deviations do not exceed the limits of experimental error (±2%). In case of larger cluster with 19 rods deviations are higher than the experimental error. Most probably the calculated values exceed the experimental ones result from the fact that in this paper the shielding correction is calculated only in the region up to 1 keV [sr

  1. Spin measurements for 147Sm+n resonances: Further evidence for nonstatistical effects

    International Nuclear Information System (INIS)

    Koehler, P. E.; Ullmann, J. L.; Bredeweg, T. A.; O'Donnell, J. M.; Reifarth, R.; Rundberg, R. S.; Vieira, D. J.; Wouters, J. M.

    2007-01-01

    We have determined the spins J of resonances in the 147 Sm(n,γ) reaction by measuring multiplicities of γ-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 141 known resonances below E n =1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignments, together with previously determined resonance parameters, allowed us to extract level spacings (D 0,3 =11.76±0.93 and D 0,4 =11.21±0.85 eV) and neutron strength functions (10 4 S 0,3 =4.70±0.91 and 10 4 S 0,4 =4.93±0.92) for J=3 and 4 resonances, respectively. Furthermore, cumulative numbers of resonances and cumulative reduced neutron widths as functions of resonance energy indicate that very few resonances of either spin have been missed below E n =700 eV. This conclusion is strengthened by the facts that, over this energy range, Wigner distributions calculated using these D 0 values agree with the measured nearest-neighbor level spacings to within the experimental uncertainties, and that the Δ 3 values calculated from the data also agree with the expected values. Because a nonstatistical effect recently was reported near E n =350 eV from an analysis of 147 Sm(n,α) data, we divided the data into two regions; 0 n n n 0 distribution for resonances below 350 eV is consistent with the expected Porter-Thomas distribution. However, we found that Γ n 0 data in the 350 n 2 distribution having ν≥2 We discuss possible explanations for these observed nonstatistical effects and their possible relation to similar effects previously observed in other nuclides

  2. Ultrasensitive mass sensor fully integrated with complementary metal-oxide-semiconductor circuitry

    DEFF Research Database (Denmark)

    Forsén, Esko Sebastian; Abadal, G.; Ghatnekar-Nilsson, S.

    2005-01-01

    Nanomechanical resonators have been monolithically integrated on preprocessed complementary metal-oxide-semiconductor (CMOS) chips. Fabricated resonator systems have been designed to have resonance frequencies up to 1.5 MHz. The systems have been characterized in ambient air and vacuum conditions...... and display ultrasensitive mass detection in air. A mass sensitivity of 4 ag/Hz has been determined in air by placing a single glycerine drop, having a measured weight of 57 fg, at the apex of a cantilever and subsequently measuring a frequency shift of 14.8 kHz. CMOS integration enables electrostatic...

  3. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  4. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  5. Fuzzy measures and integrals

    Czech Academy of Sciences Publication Activity Database

    Mesiar, Radko

    2005-01-01

    Roč. 28, č. 156 (2005), s. 365-370 ISSN 0165-0114 R&D Projects: GA ČR(CZ) GA402/04/1026 Institutional research plan: CEZ:AV0Z10750506 Keywords : fuzzy measures * fuzzy integral * regular fuzzy integral Subject RIV: BA - General Mathematics Impact factor: 1.039, year: 2005

  6. Electron beam asymmetry measurements from exclusive pi0 electroproduction in the Delta(1232) resonance region

    Energy Technology Data Exchange (ETDEWEB)

    K. Joo

    2003-05-01

    The polarized longitudinal-transverse structure function sigma_LT'in the p(e,e'p)pi^0 reaction has been measured for the first time in the Delta(1232) resonance region for invariant mass W = 1.1 - 1.3 GeV and at four-momentum transfer Q^2 = 0.40 and 0.65 GeV^2. Data were taken at the Thomas Jefferson National Accelerator Facility with the CEBAF Large Acceptance Spectrometer (CLAS) using longitudinally polarized electrons at an energy of 1.515 GeV. This newly measured sigma_LT' provides new and unique information on the interference between resonant and non-resonant amplitudes in the Delta(1232) resonance region. The comparison to recent phenomenological calculations shows sensitivity to the description of non-resonant amplitudes and higher resonances.

  7. Spatially resolved remote measurement of temperature by neutron resonance absorption

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [Space Sciences Laboratory, University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Kockelmann, W.; Pooley, D.E. [STFC, Rutherford Appleton Laboratory, ISIS Facility, Didcot OX11 0QX (United Kingdom); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Road, Sturbridge, MA 01566 (United States)

    2015-12-11

    Deep penetration of neutrons into most engineering materials enables non-destructive studies of their bulk properties. The existence of sharp resonances in neutron absorption spectra enables isotopically-resolved imaging of elements present in a sample, as demonstrated by previous studies. At the same time the Doppler broadening of resonance peaks provides a method of remote measurement of temperature distributions within the same sample. This technique can be implemented at a pulsed neutron source with a short initial pulse allowing for the measurement of the energy of each registered neutron by the time of flight technique. A neutron counting detector with relatively high timing and spatial resolution is used to demonstrate the possibility to obtain temperature distributions across a 100 µm Ta foil with ~millimeter spatial resolution. Moreover, a neutron transmission measurement over a wide energy range can provide spatially resolved sample information such as temperature, elemental composition and microstructure properties simultaneously.

  8. Ultrasensitive thermometer for atmospheric pressure operation based on a micromechanical resonator

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Pini, V.; Tamayo, J.

    2014-01-01

    For highly integrated systems for bio and chemical analysis a precise and integrated measurement of temperature is of fundamental importance. We have developed an ultrasensitive thermometer based on a micromechanical resonator for operation in air. The high quality factor and the strong temperatu...

  9. Electroweak coupling measurements from polarized Bhabha scattering at the Z0 resonance

    International Nuclear Information System (INIS)

    Pitts, K.T.

    1994-03-01

    The cross section for Bhabha scattering (e + e - → e + e - ) with polarized electrons at the center of mass energy of the Z 0 resonance has been measured with the SLD experiment at the Stanford Linear Accelerator Center during the 1992 and 1993 runs. The electroweak couplings of the electron are extracted. At small angles the measurement is done in the SLD Silicon/Tungsten Luminosity Monitor (LMSAT). A detailed description of the design, construction, commissioning and operation of the LMSAT is provided. The integrated luminosity for 1992 is measured to be L = 420.86±2.56 (stat)±4.23 (sys) nb -1 . The luminosity asymmetry for polarized beams is measured to be A LR (LUM) = (1.7 ± 6.4) x 10 -3 . The large angle polarized Bhabha scattering reveals the effective electron vector and axial vector couplings to the Z 0 through the measurement of the Z 0 → e + e - partial width, Γ ee , and the parity violation parameter, A e . From the combined 1992 and 1993 data the effective electron vector and axial vector couplings are measured to be bar g v e = -0.0495±0.0096±0.0030, and bar g α e = -0.4977±0.0035±0.0064 respectively. The effective weak mixing angle is measured to be sin 2 θ W eff = 0.2251±0.0049±0.0015. These results are compared with other experiments

  10. Resonance effects in elastic cross sections for electron scattering on pyrimidine: Experiment and theory.

    Science.gov (United States)

    Regeta, Khrystyna; Allan, Michael; Winstead, Carl; McKoy, Vincent; Mašín, Zdeněk; Gorfinkiel, Jimena D

    2016-01-14

    We measured differential cross sections for elastic (rotationally integrated) electron scattering on pyrimidine, both as a function of angle up to 180(∘) at electron energies of 1, 5, 10, and 20 eV and as a function of electron energy in the range 0.1-14 eV. The experimental results are compared to the results of the fixed-nuclei Schwinger variational and R-matrix theoretical methods, which reproduce satisfactorily the magnitudes and shapes of the experimental cross sections. The emphasis of the present work is on recording detailed excitation functions revealing resonances in the excitation process. Resonant structures are observed at 0.2, 0.7, and 4.35 eV and calculations for different symmetries confirm their assignment as the X̃(2)A2, Ã(2)B1, and B̃(2)B1 shape resonances. As a consequence of superposition of coherent resonant amplitudes with background scattering the B̃(2)B1 shape resonance appears as a peak, a dip, or a step function in the cross sections recorded as a function of energy at different scattering angles and this effect is satisfactorily reproduced by theory. The dip and peak contributions at different scattering angles partially compensate, making the resonance nearly invisible in the integral cross section. Vibrationally integrated cross sections were also measured at 1, 5, 10 and 20 eV and the question of whether the fixed-nuclei cross sections should be compared to vibrationally elastic or vibrationally integrated cross section is discussed.

  11. Method of allowing for resonances in calculating reactivity values

    International Nuclear Information System (INIS)

    Kumpf, H.

    1985-01-01

    On the basis of the integral transport equation for the source density an expression has been derived for calculating reactivity values taking resonances in the core and in the sample into account. The model has been used for evaluating reactivities measured in the Rossendorf SEG IV configuration. It is shown that the influence of resonances in the core can be kept tolerable, if a sufficiently thick buffer zone of only slightly absorbing non-resonant material is arranged between the sample and the core. (author)

  12. Piezoresistive silicon nanowire resonators as embedded building blocks in thick SOI

    Science.gov (United States)

    Nasr Esfahani, Mohammad; Kilinc, Yasin; Çagatay Karakan, M.; Orhan, Ezgi; Hanay, M. Selim; Leblebici, Yusuf; Erdem Alaca, B.

    2018-04-01

    The use of silicon nanowire resonators in nanoelectromechanical systems for new-generation sensing and communication devices faces integration challenges with higher-order structures. Monolithic and deterministic integration of such nanowires with the surrounding microscale architecture within the same thick crystal is a critical aspect for the improvement of throughput, reliability and device functionality. A monolithic and IC-compatible technology based on a tuned combination of etching and protection processes was recently introduced yielding silicon nanowires within a 10 μ m-thick device layer. Motivated by its success, the implications of the technology regarding the electromechanical resonance are studied within a particular setting, where the resonator is co-fabricated with all terminals and tuning electrodes. Frequency response is measured via piezoresistive readout with frequency down-mixing. Measurements indicate mechanical resonance with frequencies as high as 100 MHz exhibiting a Lorentzian behavior with proper transition to nonlinearity, while Allan deviation on the order of 3-8 ppm is achieved. Enabling the fabrication of silicon nanowires in thick silicon crystals using conventional semiconductor manufacturing, the present study thus demonstrates an alternative pathway to bottom-up and thin silicon-on-insulator approaches for silicon nanowire resonators.

  13. Ultraminiature resonator accelerometer

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D.R.; Kravitz, S.H.; Vianco, P.T.

    1996-04-01

    A new family of microminiature sensors and clocks is being developed with widespread application potential for missile and weapons applications, as biomedical sensors, as vehicle status monitors, and as high-volume animal identification and health sensors. To satisfy fundamental technology development needs, a micromachined clock and an accelerometer have initially been undertaken as development projects. A thickness-mode quartz resonator housed in a micromachined silicon package is used as the frequency-modulated basic component of the sensor family. Resonator design philosophy follows trapped energy principles and temperature compensation methodology through crystal orientation control, with operation in the 20--100 MHz range, corresponding to quartz wafer thicknesses in the 75--15 micron range. High-volume batch-processing manufacturing is utilized, with package and resonator assembly at the wafer level. Chemical etching of quartz, as well as micromachining of silicon, achieves the surface and volume mechanical features necessary to fashion the resonating element and the mating package. Integration of the associated oscillator and signal analysis circuitry into the silicon package is inherent to the realization of a size reduction requirement. A low temperature In and In/Sn bonding technology allows assembly of the dissimilar quartz and silicon materials, an otherwise challenging task. Unique design features include robust vibration and shock performance, capacitance sensing with micromachined diaphragms, circuit integration, capacitance-to-frequency transduction, and extremely small dimensioning. Accelerometer sensitivities were measured in the 1--3 ppm/g range for the milligram proof-mass structures employed in the prototypes evaluated to date.

  14. Crossing simple resonances

    International Nuclear Information System (INIS)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances

  15. Crossing simple resonances

    Energy Technology Data Exchange (ETDEWEB)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances.

  16. Analog implementation of an integral resonant control scheme

    International Nuclear Information System (INIS)

    Pereira, E; Moheimani, S O R; Aphale, S S

    2008-01-01

    Integral resonant control (IRC) has been introduced as a high performance controller design methodology for flexible structures with collocated actuator–sensor pairs. IRC has a simple structure and is capable of achieving significant damping, over several modes, while guaranteeing closed-loop stability of the system in the presence of unmodeled out-of-bandwidth dynamics. IRC can be an ideal controller for various industrial damping applications, if packaged in a simple easy-to-implement electronic module. This work proposes an analog implementation of the IRC scheme using a single Op-Amp circuit. The objective is to show that with simple analog realization of the modified IRC scheme, it is possible to damp a large number of vibration modes. A brief discussion about the modeling, circuit considerations, implementation and experimental results is presented in order to validate the usefulness and practicality of the proposed analog IRC implementation. (technical note)

  17. Image-based overlay measurement using subsurface ultrasonic resonance force microscopy

    Science.gov (United States)

    Tamer, M. S.; van der Lans, M. J.; Sadeghian, H.

    2018-03-01

    Image Based Overlay (IBO) measurement is one of the most common techniques used in Integrated Circuit (IC) manufacturing to extract the overlay error values. The overlay error is measured using dedicated overlay targets which are optimized to increase the accuracy and the resolution, but these features are much larger than the IC feature size. IBO measurements are realized on the dedicated targets instead of product features, because the current overlay metrology solutions, mainly based on optics, cannot provide sufficient resolution on product features. However, considering the fact that the overlay error tolerance is approaching 2 nm, the overlay error measurement on product features becomes a need for the industry. For sub-nanometer resolution metrology, Scanning Probe Microscopy (SPM) is widely used, though at the cost of very low throughput. The semiconductor industry is interested in non-destructive imaging of buried structures under one or more layers for the application of overlay and wafer alignment, specifically through optically opaque media. Recently an SPM technique has been developed for imaging subsurface features which can be potentially considered as a solution for overlay metrology. In this paper we present the use of Subsurface Ultrasonic Resonance Force Microscopy (SSURFM) used for IBO measurement. We used SSURFM for imaging the most commonly used overlay targets on a silicon substrate and photoresist. As a proof of concept we have imaged surface and subsurface structures simultaneously. The surface and subsurface features of the overlay targets are fabricated with programmed overlay errors of +/-40 nm, +/-20 nm, and 0 nm. The top layer thickness changes between 30 nm and 80 nm. Using SSURFM the surface and subsurface features were successfully imaged and the overlay errors were extracted, via a rudimentary image processing algorithm. The measurement results are in agreement with the nominal values of the programmed overlay errors.

  18. Evaluation of neutron nuclear data for 233U in thermal and resonance regions

    International Nuclear Information System (INIS)

    Kikuchi, Yasuyuki

    1981-02-01

    The thermal and resonance cross sections of 233 U were evaluated for JENDL-2. The cross sections below 1 eV are given as point-wise data and were evaluated by the use of the measured fission and capture cross sections. The resolved resonance parameters are derived up to 100 eV. The parameters were obtained by using NDES so as to reproduce the measured total and fission cross sections. The cross sections from 100 eV to 30 keV are represented by the unresolved resonance parameters. The fission and capture resonance integrals calculated from these parameters are 771 and 138 barns, respectively, which agree with the measured data within the quoted errors. (author)

  19. Efficient method for the solution of the energy dependent integral Boltzmann transport equation in the resolved resonance energy region

    International Nuclear Information System (INIS)

    Schwenk, G.A. Jr.

    1980-01-01

    The calculation of neutron-nuclei reaction rates in the lower resolved resonance region (167 eV - 1.855 eV) is considered in this dissertation. Particular emphasis is placed on the calculation of these reaction rates for tight lattices where their accuracy is most important. The results of the continuous energy Monte Carlo code, VIM, are chosen as reference values for this study. The primary objective of this work is to develop a method for calculating resonance reaction rates which agree well with the reference solution, yet is efficient enough to be used by nuclear reactor fuel cycle designers on a production basis. A very efficient multigroup solution of the two spatial region energy dependent integral transport equation is developed. This solution, denoted the Broad Group Integral Method (BGIM), uses escape probabilities to obtain the spatial coupling between regions and uses an analytical flux shape within a multigroup to obtain weighted cross sections which account for the rapidly varying resonance cross sections. The multigroup lethargy widths chosen for the numerical integration of the two region energy-dependent neutron continuity equations can be chosen much wider (a factor of 30 larger) than in the direct numerical integration methods since the analytical flux shape is used to account for fine structure effects. The BGIM solution is made highly efficient through the use of these broad groups. It is estimated that for a 10 step unit cell fuel cycle depletion calculation, the computer running time for a production code such as EPRI-LEOPARD would be increased by only 6% through the use of the more accurate and intricate BGIM method in the lower resonance energy region

  20. Calculation and measurement of radiation corrections for plasmon resonances in nanoparticles

    Science.gov (United States)

    Hung, L.; Lee, S. Y.; McGovern, O.; Rabin, O.; Mayergoyz, I.

    2013-08-01

    The problem of plasmon resonances in metallic nanoparticles can be formulated as an eigenvalue problem under the condition that the wavelengths of the incident radiation are much larger than the particle dimensions. As the nanoparticle size increases, the quasistatic condition is no longer valid. For this reason, the accuracy of the electrostatic approximation may be compromised and appropriate radiation corrections for the calculation of resonance permittivities and resonance wavelengths are needed. In this paper, we present the radiation corrections in the framework of the eigenvalue method for plasmon mode analysis and demonstrate that the computational results accurately match analytical solutions (for nanospheres) and experimental data (for nanorings and nanocubes). We also demonstrate that the optical spectra of silver nanocube suspensions can be fully assigned to dipole-type resonance modes when radiation corrections are introduced. Finally, our method is used to predict the resonance wavelengths for face-to-face silver nanocube dimers on glass substrates. These results may be useful for the indirect measurements of the gaps in the dimers from extinction cross-section observations.

  1. Measurements of line overlap for resonant spoiling of x-ray lasing transitions

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Elliott, S.R.; MacGowan, B.J.; Nilsen, J.

    1994-06-01

    High-precision measurements are presented of candidate line pairs for resonant spoiling of x-ray lasing transitions in the nickel-like W 46+ , the neon-like Fe 16+ , and the neon-like La 47+ x-ray lasers. Our measurements were carried out with high-resolution crystal spectrometers, and a typical precision of 20--50 ppM was achieved. While most resonances appear insufficient for effective photo-spoiling, two resonance pairs are identified that provide a good overlap. These are the 4p 1/2 → 3d 3/2 transition in nickel-like W 46+ with the 2p 3/2 → 1s 1/2 transition in hydrogenic Al 12+ , and the 3s 1/2 → 2p 3/2 transition in neon-like La 47+ with the 1 1 S 0 -2 1 P 1 line in heliumlike Ti 20+

  2. Theoretical evaluation of self-shielding factors due to scattering resonances in foils

    International Nuclear Information System (INIS)

    Selander, W.N.

    1960-06-01

    A semi-analytical method is given for evaluating self-shielding factors for activation measurements which use thin foils having neutron scattering resonances. The energy loss by scattering in the foil is taken into account. The energy-dependent neutron angular distribution is expanded as a double series, the coefficients of which are (energy dependent) solutions of an infinite set of coupled integral equations. These are truncated in some suitable manner and solved numerically. The leading term of the series is proportional to the average, or effective flux in the activation sample. The product of this terra and the neutron capture cross-section is integrated numerically over the resonance to give the resonance self-shielding correction. Figure 4 shows resonance self-shielding factors derived in this mariner for the 132ev resonance in Co-59 and figure 5 shows similar results for the two Mn-55 resonances at 337ev and 1080ev. Self-shielding factors for 1/v capture are not significantly different from unity. (author)

  3. Detailing the relation between renal T2* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements.

    Science.gov (United States)

    Pohlmann, Andreas; Arakelyan, Karen; Hentschel, Jan; Cantow, Kathleen; Flemming, Bert; Ladwig, Mechthild; Waiczies, Sonia; Seeliger, Erdmann; Niendorf, Thoralf

    2014-08-01

    This study was designed to detail the relation between renal T2* and renal tissue pO2 using an integrated approach that combines parametric magnetic resonance imaging (MRI) and quantitative physiological measurements (MR-PHYSIOL). Experiments were performed in 21 male Wistar rats. In vivo modulation of renal hemodynamics and oxygenation was achieved by brief periods of aortic occlusion, hypoxia, and hyperoxia. Renal perfusion pressure (RPP), renal blood flow (RBF), local cortical and medullary tissue pO2, and blood flux were simultaneously recorded together with T2*, T2 mapping, and magnetic resonance-based kidney size measurements (MR-PHYSIOL). Magnetic resonance imaging was carried out on a 9.4-T small-animal magnetic resonance system. Relative changes in the invasive quantitative parameters were correlated with relative changes in the parameters derived from MRI using Spearman analysis and Pearson analysis. Changes in T2* qualitatively reflected tissue pO2 changes induced by the interventions. T2* versus pO2 Spearman rank correlations were significant for all interventions, yet quantitative translation of T2*/pO2 correlations obtained for one intervention to another intervention proved not appropriate. The closest T2*/pO2 correlation was found for hypoxia and recovery. The interlayer comparison revealed closest T2*/pO2 correlations for the outer medulla and showed that extrapolation of results obtained for one renal layer to other renal layers must be made with due caution. For T2* to RBF relation, significant Spearman correlations were deduced for all renal layers and for all interventions. T2*/RBF correlations for the cortex and outer medulla were even superior to those between T2* and tissue pO2. The closest T2*/RBF correlation occurred during hypoxia and recovery. Close correlations were observed between T2* and kidney size during hypoxia and recovery and for occlusion and recovery. In both cases, kidney size correlated well with renal vascular conductance

  4. The Tracking Resonance Frequency Method for Photoacoustic Measurements Based on the Phase Response

    Science.gov (United States)

    Suchenek, Mariusz

    2017-04-01

    One of the major issues in the use of the resonant photoacoustic cell is the resonance frequency of the cell. The frequency is not stable, and its changes depend mostly on temperature and gas mixture. This paper presents a new method for tracking resonance frequency, where both the amplitude and phase are calculated from the input samples. The stimulating frequency can be adjusted to the resonance frequency of the cell based on the phase. This method was implemented using a digital measurement system with an analog to digital converter, field programmable gate array (FPGA) and a microcontroller. The resonance frequency was changed by the injection of carbon dioxide into the cell. A theoretical description and experimental results are also presented.

  5. Continuous neutron slowing down theory applied to resonances

    International Nuclear Information System (INIS)

    Segev, M.

    1977-01-01

    Neutronic formalisms that discretize the neutron slowing down equations in large numerical intervals currently account for the bulk effect of resonances in a given interval by the narrow resonance approximation (NRA). The NRA reduces the original problem to an efficient numerical formalism through two assumptions: resonance narrowness with respect to the scattering bands in the slowing down equations and resonance narrowness with respect to the numerical intervals. Resonances at low energies are narrow neither with respect to the slowing down ranges nor with respect to the numerical intervals, which are usually of a fixed lethargy width. Thus, there are resonances to which the NRA is not applicable. To stay away from the NRA, the continuous slowing down (CSD) theory of Stacey was invoked. The theory is based on a linear expansion in lethargy of the collision density in integrals of the slowing down equations and had notable success in various problems. Applying CSD theory to the assessment of bulk resonance effects raises the problem of obtaining efficient quadratures for integrals involved in the definition of the so-called ''moderating parameter.'' The problem was solved by two approximations: (a) the integrals were simplified through a rationale, such that the correct integrals were reproduced for very narrow or very wide resonances, and (b) the temperature-broadened resonant line shapes were replaced by nonbroadened line shapes to enable analytical integration. The replacement was made in such a way that the integrated capture and scattering probabilities in each resonance were preserved. The resulting formalism is more accurate than the narrow-resonance formalisms and is equally as efficient

  6. Comparison among T1-weighted magnetic resonance imaging, modified dixon method, and magnetic resonance spectroscopy in measuring bone marrow fat.

    Science.gov (United States)

    Shen, Wei; Gong, Xiuqun; Weiss, Jessica; Jin, Ye

    2013-01-01

    An increasing number of studies are utilizing different magnetic resonance (MR) methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI), modified Dixon method (also called fat fraction MRI (FFMRI)), and magnetic resonance spectroscopy (MRS). Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI). Bone marrow adipose tissue (BMAT) of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 (P BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 (P < 0.001) in femoral necks. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  7. Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantilevers for early-stage diagnosis of heptocellular carcinoma.

    Science.gov (United States)

    Liu, Yongjing; Li, Xinxin; Zhang, Zhixiang; Zuo, Guomin; Cheng, Zhenxing; Yu, Haitao

    2009-02-01

    Nanogram per milliliter-level ultra-low concentration detection of alpha-fetoprotein (AFP), which is an important marker for heptocellular carcinoma, is in favor of early-stage prognosis and disease diagnosis. On-the-spot rapid detection of such antigens as AFP highly requires innovative micro/nano techniques. To meet this requirement, an advanced resonant microcantilever is developed and used for screening the tumor marker at nanogram per milliliter level. The sensing principle of the resonant microcantilever is measuring frequency-shift versus specific-adsorbed mass. With both electromagnetic resonance-exciting and piezoresistive readout elements on-chip integrated, the microcantilever sensor is operated in a rotating resonance mode to improve sensitivity and resolution to specific mass adsorption. Prior to detection of AFP with previously immobilized anti-AFP antibody, the antigen-antibody specific-binding is confirmed with an enzyme linked immunosorbent assay experiment. By implementing the specific reaction in liquid and reading out the sensor signal in lab air environment, the micromechanical sensor has achieved the sensitive scale between 2 and 20 ng/ml. To effectively depress cross-talk signal and improve resolution, the insensitive regions of the cantilever surface are pre-modified with 2-[methoxy (polyethyleneoxy) propyl] trimethoxysilane for nonspecific bio-adsorption minimization. Finally, a better AFP detecting limit than 2 ng/mL is experimentally achieved. The label-free resonant microcantilever sensor is promising in low-cost or even disposable early-stage prognosis and diagnosis of tumors.

  8. Resonant ultrasound spectroscopy and non-destructive testing

    Science.gov (United States)

    Migliori, A.; Darling, T. W.

    The use of mechanical resonances to test properties of materials is perhaps older than the industrial revolution. Early documented cases of British railroad engineers tapping the wheels of a train and using the sound to detect cracks perhaps mark the first real use of resonances to test the integrity of high-performance alloys. Attempts were made in the following years to understand the resonances of solids mathematically, based on the shape and composition. But Nobel Laureate Lord Rayleigh best summarized the state of affairs in 1894, stating 'the problem has, for the most part, resisted attack'. More recently, modern computers and electronics have enabled Anderson and co-workers with their work on minerals, and our work at Los Alamos on new materials and manufactured components to advance the use of resonances to a precision non-destructive testing tool that makes anisotropic modulus measurements, defect detection and geometry error detection routine. The result is that resonances can achieve the highest absolute accuracy for any dynamic modulus measurement technique, can be used on the smallest samples, and can also enable detection of errors in certain classes of precision manufactured components faster and more accurately than any other technique.

  9. Integrated nanohole array surface plasmon resonance sensing device using a dual-wavelength source

    International Nuclear Information System (INIS)

    Escobedo, C; Vincent, S; Choudhury, A I K; Campbell, J; Gordon, R; Brolo, A G; Sinton, D

    2011-01-01

    In this paper, we demonstrate a compact integrated nanohole array-based surface plasmon resonance sensing device. The unit includes a LED light source, driving circuitry, CCD detector, microfluidic network and computer interface, all assembled from readily available commercial components. A dual-wavelength LED scheme was implemented to increase spectral diversity and isolate intensity variations to be expected in the field. The prototype shows bulk sensitivity of 266 pixel intensity units/RIU and a limit of detection of 6 × 10 −4 RIU. Surface binding tests were performed, demonstrating functionality as a surface-based sensing system. This work is particularly relevant for low-cost point-of-care applications, especially those involving multiple tests and field studies. While nanohole arrays have been applied to many sensing applications, and their suitability to device integration is well established, this is the first demonstration of a fully integrated nanohole array-based sensing device.

  10. LEP precision electroweak measurements from the Z{sup 0} resonance

    Energy Technology Data Exchange (ETDEWEB)

    Strom, D. [Univ. of Oregon, Eugene, OR (United States)

    1997-01-01

    Preliminary electroweak measurements from the LEP Collaboration from data taken at the Z{sup 0} resonance are presented. Most of the results presented are based on a total data sample of 12 x 10{sup 6} recorded Z{sup 0} events which included data from the 1993 and 1994 LEP runs. The Z{sup 0} resonance parameters, including hadronic and leptonic cross sections and asymmetries, {tau} polarization and its asymmetry, and heavy-quark asymmetries and partial widths, are evaluated and confronted with the predictions of the Standard Model. This comparison incorporates the constraints provided by the recent determination of the top-quark mass at the Tevatron. The Z{sup 0} resonance parameters are found to be in good agreement with the Standard Model prediction using the Tevatron top-quark mass, with the exception of the partial widths for Z{sup 0} decays to pairs of b and c quarks.

  11. Chip-integrated optical power limiter based on an all-passive micro-ring resonator

    Science.gov (United States)

    Yan, Siqi; Dong, Jianji; Zheng, Aoling; Zhang, Xinliang

    2014-10-01

    Recent progress in silicon nanophotonics has dramatically advanced the possible realization of large-scale on-chip optical interconnects integration. Adopting photons as information carriers can break the performance bottleneck of electronic integrated circuit such as serious thermal losses and poor process rates. However, in integrated photonics circuits, few reported work can impose an upper limit of optical power therefore prevent the optical device from harm caused by high power. In this study, we experimentally demonstrate a feasible integrated scheme based on a single all-passive micro-ring resonator to realize the optical power limitation which has a similar function of current limiting circuit in electronics. Besides, we analyze the performance of optical power limiter at various signal bit rates. The results show that the proposed device can limit the signal power effectively at a bit rate up to 20 Gbit/s without deteriorating the signal. Meanwhile, this ultra-compact silicon device can be completely compatible with the electronic technology (typically complementary metal-oxide semiconductor technology), which may pave the way of very large scale integrated photonic circuits for all-optical information processors and artificial intelligence systems.

  12. Slowing down with resonance absorption

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Nair, R.P.K.

    1979-08-01

    The presence of heavy nuclei in nuclear reactors, in significant concentrations, facilitates the appearance of absorption resonances. For the moderation in the presence of absorbers an exact solution of the integral equations is possible by numerical methods. Approximated solutions for separated resonances in function of the practical width, (NR and NRIM approximations) are discussed in this paper. The method is generalized, presenting the solution by an intermediate approximation, in the definition of the resonance integral. (Author) [pt

  13. Studies of the Effective Total and Resonance Absorption Cross Sections for Zircaloy 2 and Zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Hellstrand, E; Lindahl, G; Lundgren, G

    1961-06-15

    Using pile oscillator technique, the total absorption cross section for zircaloy 2 plates has been determined in the neutron spectrum of the reactor R1. The plate thickness was varied in six steps from 0. 2 mm to 6. 4 mm. The thermal cross section for the alloy was calculated from cross section data and the known composition of the alloy. By subtracting this value from the measured cross sections and dividing by the factor {alpha}=2/{radical}({pi}) x r x {radical}(T/T{sub 0}) the effective resonance integrals were obtained. After subtraction of a constant amount for resonance contributions from hafnium, tin etc., effective resonance integrals for zirconium could be evaluated. An extrapolated value of 0.85 {+-} 0.15 b was obtained for the infinitely dilute integral (l/v part excluded). The ratio of the resonance integral at plate thicknesses 0.2 and 6.4 mm came out as 1.65 {+-} 0.25.

  14. Modeling of supermodes in coupled unstable resonators

    International Nuclear Information System (INIS)

    Townsend, S.S.

    1986-01-01

    A general formalism describing the supermodes of an array of N identical, circulantly coupled resonators is presented. The symmetry of the problem results in a reduction of the N coupled integral equations to N decoupled integral equations. Each independent integral equation defines a set of single-resonator modes derived for a hypothetical resonator whose geometry resembles a member of the real array with the exception that all coupling beams are replaced by feedback beams, each with a prescribed constant phase. A given array supermode consists of a single equivalent resonator mode appearing repetitively in each resonator with a prescribed relative phase between individual resonators. The specific array design chosen for example is that of N adjoint coupled confocal unstable resonators. The impact of coupling on the computer modeling of this system is discussed and computer results for the cases of two- and four-laser coupling are presented

  15. Thermal neutron cross sections and resonance integrals for the 1994 handbook of chemistry and physics

    International Nuclear Information System (INIS)

    Holden, N.E.

    1994-01-01

    A re-evaluation of all thermal neutron cross sections and neutron resonance integrals has been performed, utilizing the previous database of the ''Barn Book'' and all of the more recently published experiments. Only significant changes or previously undetermined values are recorded in this report. The source for each value is also recorded in the accompanying table

  16. Determination of the resonance parameters for 232Th from high resolution transmission and capture measurements at GELINA

    International Nuclear Information System (INIS)

    Brusegan, A.; Schillebeeckx, P.; Lobo, G.; Borella, A.; Volev, K.; Janeva, N.

    2003-01-01

    To deduce the resonance parameters for 232 Th in the resolved resonance region, high resolution transmission and capture measurements are being performed. The measurements are performed at the Time-Of-Flight facility GELINA. A comparison of experimental data resulting from capture (top) and transmission (bottom) are shown. The transmission measurements are performed at a 50 m flight path. The neutron are detected with a 0.25' thick lithium glass (NE912) placed in an Al sphere and viewed by a 5' EMI KQB photomultiplier orthogonal to the neutron beam axis. The injection of a stabilised light pulse in the detector during the measurements provided an efficient tool to control to better than 1% the gain of the entire electronics. The experimental set-up includes a sample-changer, placed at 23 m from the neutron source, which is driven by the acquisition system. The determination of the flight path length, was based on transmission of the 6.673 eV resonance of 238 U. We summarise, for the different energy regions of interest, the scheduled measurement conditions: the operation frequency of the accelerator and the target thickness. A simultaneous analysis of the data using REFIT will result in the resonance parameters from 0 to 4 keV. We show the result of a resonance shape analysis for the resonances at 21.8 and 23.5 eV. The resulting resonance parameters are important for the energy calibration and normalisation of the capture measurements in both the resolved and unresolved resonance region. The capture measurements are completed and were performed at a 60 m flight path. The sample consisted of a metallic natural thorium disc of 8 cm diameter and 1.0 mm thick, corresponding to a thickness of 3.176 10 -3 at/b. The neutron flux was measured with an ionisation chamber loaded with three back-to-back layers of about 40 μg/cm 2 10 B. The gamma rays, originating from the 232 Th(n,γ) reaction, were detected by four C 6 D 6 -based liquid scintillators (NE230) placed

  17. Electron cloud density measurements in accelerator beam-pipe using resonant microwave excitation

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, John P., E-mail: jps13@cornell.edu [CLASSE, Cornell University, Ithaca, NY 14853 (United States); Carlson, Benjamin T. [Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Duggins, Danielle O. [Gordon College, Wenham, MA 01984 (United States); Hammond, Kenneth C. [Columbia University, New York, NY 10027 (United States); De Santis, Stefano [LBNL, Berkeley, CA 94720 (United States); Tencate, Alister J. [Idaho State University, Pocatello, ID 83209 (United States)

    2014-08-01

    An accelerator beam can generate low energy electrons in the beam-pipe, generally called electron cloud, that can produce instabilities in a positively charged beam. One method of measuring the electron cloud density is by coupling microwaves into and out of the beam-pipe and observing the response of the microwaves to the presence of the electron cloud. In the original technique, microwaves are transmitted through a section of beam-pipe and a change in EC density produces a change in the phase of the transmitted signal. This paper describes a variation on this technique in which the beam-pipe is resonantly excited with microwaves and the electron cloud density calculated from the change that it produces in the resonant frequency of the beam-pipe. The resonant technique has the advantage that measurements can be localized to sections of beam-pipe that are a meter or less in length with a greatly improved signal to noise ratio.

  18. Measurements of neutron cross sections of radioactive waste nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Toshio [Gifu College of Medical Technology, Seki, Gifu (Japan); Harada, Hideo; Nakamura, Shoji; Tanase, Masakazu; Hatsukawa, Yuichi

    1998-01-01

    Accurate nuclear reaction cross sections of radioactive fission products and transuranic elements are required for research on nuclear transmutation methods in nuclear waste management. Important fission products in the nuclear waste management are {sup 137}Cs, {sup 135}Cs, {sup 90}Sr, {sup 99}Tc and {sup 129}I because of their large fission yields and long half-lives. The present authors have measured the neutron capture cross sections and resonance integrals of {sup 137}Cs, {sup 90}Sr and {sup 99}Tc. The purpose of this study is to measure the neutron capture cross sections and resonance integrals of nuclides, {sup 129}I and {sup 135}Cs accurately. Preliminary experiments were performed by using Rikkyo University Reactor and JRR-3 reactor at Japan Atomic Energy Research Institute (JAERI). Then, it was decided to measure the cross section and resonance integral of {sup 135}Cs by using the JRR-3 Reactor because this measurement required a high flux reactor. On the other hand, those of {sup 129}I were measured at the Rikkyo Reactor because the product nuclides, {sup 130}I and {sup 130m}I, have short half-lives and this reactor is suitable for the study of short lived nuclide. In this report, the measurements of the cross section and resonance integral of {sup 135}Cs are described. To obtain reliable values of the cross section and resonance integral of {sup 135}Cs(n, {gamma}){sup 136}Cs reaction, a quadrupole mass spectrometer was used for the mass analysis of nuclide in the sample. A progress report on the cross section of {sup 134}Cs, a neighbour of {sup 135}Cs, is included in this report. A report on {sup 129}I will be presented in the Report on the Joint-Use of Rikkyo University Reactor. (author)

  19. Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator

    CERN Document Server

    Keckert, Sebastian; Knobloch, Jens; Kugeler, Oliver

    2015-01-01

    The systematic research on superconducting thin films requires dedicated testing equipment. The Quadrupole Resonator (QPR) is a specialized tool to characterize the superconducting RF properties of circular planar samples. A calorimetric measurement of the RF surface losses allows the surface resistance to be measured with sub nano-ohm resolution. This measurement can be performed over a wide temperature and magnetic field range, at frequencies of 433, 866 and 1300 MHz. The system at Helmholtz-Zentrum Berlin (HZB) is based on a resonator built at CERN and has been optimized to lower peak electric fields and an improved resolution. In this paper the design of an alternative calorimetry chamber is presented, providing flat samples for coating which are easy changeable. All parts are connected by screwing connections and no electron beam welding is required. Furthermore this design enables exchangeability of samples between the resonators at HZB and CERN. First measurements with the new design show ambiguous r...

  20. Resonance structure of $\\tau^{-} \\to K^{-}\\pi^{+}\\pi^{-}\

    CERN Document Server

    Asner, D M; Gronberg, J B; Hill, T S; Lange, D J; Morrison, R J; Briere, R A; Behrens, B H; Ford, W T; Gritsan, A; Roy, J D; Smith, J G; Alexander, J P; Baker, R; Bebek, C; Berger, B E; Berkelman, K; Blanc, F; Boisvert, V; Cassel, David G; Dickson, M; Drell, P S; Ecklund, K M; Ehrlich, R; Foland, A D; Gaidarev, P B; Galik, R S; Gibbons, L K; Gittelman, B; Gray, S W; Hartill, D L; Heltsley, B K; Hopman, P I; Jones, C D; Kreinick, D L; Lohner, M; Magerkurth, A; Meyer, T O; Mistry, N B; Ng, C R; Nordberg, E; Patterson, J R; Peterson, D; Riley, D; Thayer, J G; Thies, P G; Valant-Spaight, B L; Watburton, A; Avery, P; Prescott, C; Rubiera, A I; Yelton, J; Zheng, J; Brandenburg, G; Ershov, A; Gao, Y S; Kim, D Y J; Wilson, R; Browder, T E; Li, Y; Rodríguez, J L; Yamamoto, H; Bergfeld, T; Eisenstein, B I; Ernst, J; Gladding, G E; Gollin, G D; Hans, R M; Johnson, E; Karliner, I; Marsh, M A; Palmer, M; Plager, C; Sedlack, C; Selen, M; Thaler, J J; Williams, J; Edwards, K W; Janicek, R; Patel, P M; Sadoff, A J; Ammar, R; Bean, A; Besson, D; Davis, R; Kravchenko, I V; Kwak, N; Zhao, X; Anderson, S; Frolov, V V; Kubota, Y; Lee, S J; Mahapatra, R; O'Neill, J J; Poling, R A; Riehle, T; Smith, A; Urheim, J; Ahmed, S; Alam, M S; Athar, S B; Jian, L; Ling, L; Mahmood, A H; Saleem, M; Timm, S; Wappler, F; Anastassov, A; Duboscq, J E; Gan, K K; Gwon, C; Hart, T; Honscheid, K; Hufnagel, D; Kagan, H; Kass, R; Pedlar, T K; Schwarthoff, H; Thayer, J B; Von Törne, E; Zoeller, M M; Richichi, S J; Severini, H; Skubic, P L; Undrus, A; Chen, S; Fast, J; Hinson, J W; Lee, J; Menon, N; Miller, D H; Shibata, E I; Shipsey, I P J; Pavlunin, V; Cronin-Hennessy, D; Kwon, Y; Lyon, A L; Thorndike, E H; Jessop, C P; Marsiske, H; Perl, Martin Lewis; Savinov, V; Ugolini, D W; Zhou, X; Coan, T E; Fadeev, V; Maravin, Y; Narsky, I; Stroynowski, R; Ye, J; Wlodek, T; Artuso, M; Ayad, R; Boulahouache, C; Bukin, K; Dambasuren, E; Karamov, S; Kopp, S E; Majumder, G; Moneti, G C; Mountain, R; Schuh, S; Skwarnicki, T; Stone, S; Viehhauser, G; Wang, J C; Wolf, A; Wu, J; Csorna, S E; Danko, I; McLean, K W; Marka, S; Xu, Z; Godang, R; Kinoshita, K; Lai, I C; Schrenk, S; Bonvicini, G; Cinabro, D; Perera, L P; Zhou, G J; Eigen, G; Lipeles, E; Schmidtler, M; Shapiro, A; Sun, W M; Weinstein, A J; Würthwein, F; Jaffe, D E; Masek, G E; Paar, H P; Potter, E M; Prell, S; Sharma, V

    2000-01-01

    Using a sample of 4.7 fb/sup -1/ integrated luminosity accumulated with the CLEO II detector at the Cornell Electron Storage Ring (CESR) , we investigate the mass spectrum and resonant structure in tau /sup -/ to K/sup -/ pi /sup +/ pi /sup -/ nu /sub tau / decays. We measure the relative fractions of K/sub 1/(1270) and K/sub 1/(1400) resonances in these decays, as well as the K/sub 1/ masses and widths. Our fitted K/sub 1/ resonances are somewhat broader than previous hadroproduction measurements, and in agreement with recent CERN LEP results from tau decay. The larger central value of our measured width supports models which attribute the small tau /sup -/ to K/sup -/ pi /sup +/ pi /sup -/ nu /sub tau / branching fraction to larger K/sub 1/ widths than are presently tabulated. We also determine the K/sub a/-K/sub b/ mixing angle theta /sub K/. (22 refs) .

  1. Piezoelectric transduction of flexural modes in pre-stressed microbeam resonators

    Science.gov (United States)

    Torri, G. B.; Janssen, N. M. A.; Zeng, Z.; Rottenberg, X.; Karabacak, D. M.; Vandecasteele, M.; Van Hoof, C.; Puers, R.; Tilmans, H. A. C.

    2014-08-01

    This paper reports on the optimization of the design of piezoelectric transducer elements integrated on doubly-clamped microbeam resonators utilized as (bio)chemical sensors. We report and emphasize the often forgotten influence of membrane stresses on defining the dimensions and optimal position of the piezoelectric transducer elements. The study takes into account stress induced structural changes and provides models for the equivalent motional parameters of resonators with particular shapes of the transducers matching the flexural modes of vibration. The above is analyzed theoretically using numerical models and is confirmed by impedance measurements and optical measurements of fabricated doubly-clamped beam resonators. We propose various transducer designs and highlight the advantages of using higher order vibration modes by implementing specially designed mode matching transducer elements. It is concluded that the paper describes and highlights the importance of accounting for the membrane stresses to optimize the resonator performance and the low power in electronic feedback of resonating sensing systems.

  2. Piezoelectric transduction of flexural modes in pre-stressed microbeam resonators

    International Nuclear Information System (INIS)

    Torri, G B; Rottenberg, X; Hoof, C Van; Puers, R; Tilmans, H A C; Janssen, N M A; Zeng, Z; Karabacak, D M; Vandecasteele, M

    2014-01-01

    This paper reports on the optimization of the design of piezoelectric transducer elements integrated on doubly-clamped microbeam resonators utilized as (bio)chemical sensors. We report and emphasize the often forgotten influence of membrane stresses on defining the dimensions and optimal position of the piezoelectric transducer elements. The study takes into account stress induced structural changes and provides models for the equivalent motional parameters of resonators with particular shapes of the transducers matching the flexural modes of vibration. The above is analyzed theoretically using numerical models and is confirmed by impedance measurements and optical measurements of fabricated doubly-clamped beam resonators. We propose various transducer designs and highlight the advantages of using higher order vibration modes by implementing specially designed mode matching transducer elements. It is concluded that the paper describes and highlights the importance of accounting for the membrane stresses to optimize the resonator performance and the low power in electronic feedback of resonating sensing systems. (paper)

  3. Measurement of resonant and $CP$ components in $\\overline{B}_s^0\\to J/\\psi\\pi^+\\pi^-$ decays

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Balagura, Vladislav; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Bauer, Thomas; Bay, Aurelio; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; van den Brand, Johannes; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Callot, Olivier; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carranza-Mejia, Hector; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coca, Cornelia; Coco, Victor; Cogan, Julien; Cogneras, Eric; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bonis, Isabelle; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dorosz, Piotr; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Esen, Sevda; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farry, Stephen; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Fitzpatrick, Conor; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Giani', Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gordon, Hamish; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Hafkenscheid, Tom; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hartmann, Thomas; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Iakovenko, Viktor; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Wallaa; Karacson, Matthias; Karbach, Moritz; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Kochebina, Olga; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanciotti, Elisa; Lanfranchi, Gaia; Langenbruch, Christoph; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Guoming; Lohn, Stefan; Longstaff, Ian; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luisier, Johan; Luo, Haofei; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Manca, Giulia; Mancinelli, Giampiero; Manzali, Matteo; Maratas, Jan; Marconi, Umberto; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Molina Rodriguez, Josue; Monteil, Stephane; Moran, Dermot; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Muresan, Raluca; Muryn, Bogdan; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pavel-Nicorescu, Carmen; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Pessina, Gianluigi; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Polok, Grzegorz; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Powell, Andrew; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redford, Sophie; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Alexander; Rinnert, Kurt; Rives Molina, Vincente; Roa Romero, Diego; Robbe, Patrick; Roberts, Douglas; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruffini, Fabrizio; Ruiz, Hugo; Ruiz Valls, Pablo; Sabatino, Giovanni; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sapunov, Matvey; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Senderowska, Katarzyna; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Oksana; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spinella, Franco; Spradlin, Patrick; Stagni, Federico; Stahl, Sascha; Steinkamp, Olaf; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teodorescu, Eliza; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Webber, Adam Dane; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiechczynski, Jaroslaw; Wiedner, Dirk; Wiggers, Leo; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wu, Suzhi; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Feng; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2014-05-14

    The resonant structure of the decay $\\overline{B}_s^0\\to J/\\psi\\pi^+\\pi^-$ is studied using data corresponding to 3 fb$^{-1}$ of integrated luminosity from $pp$ collisions by the LHC and collected by the LHCb detector. Five interfering $\\pi^+\\pi^-$ states are required to describe the decay: $f_0(980),~f_0(1500),~f_0(1790),~f_2(1270)$, and $f_2^{\\prime}(1525)$. An alternative model including these states and a non-resonant $J/\\psi \\pi^+\\pi^-$ component also provides a good description of the data. Based on the different transversity components measured for the spin-2 intermediate states, the final state is found to be compatible with being entirely $CP$-odd. The $CP$-even part is found to be $<2.3$% at 95% confidence level. The $f_0(500)$ state is not observed, allowing a limit to be set on the absolute value of the mixing angle with the $f_0(980)$ of $<7.7^{\\circ}$ at 90% confidence level, consistent with a tetraquark interpretation of the $f_0(980)$ substructure.

  4. Comparison among T1-Weighted Magnetic Resonance Imaging, Modified Dixon Method, and Magnetic Resonance Spectroscopy in Measuring Bone Marrow Fat

    Directory of Open Access Journals (Sweden)

    Wei Shen

    2013-01-01

    Full Text Available Introduction. An increasing number of studies are utilizing different magnetic resonance (MR methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI, modified Dixon method (also called fat fraction MRI (FFMRI, and magnetic resonance spectroscopy (MRS. Methods. Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI. Bone marrow adipose tissue (BMAT of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Results. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 in the L3 vertebra. Correlation between BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 in femoral necks. Conclusion. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  5. Pulse advancement and delay in an integrated optical two-port ring-resonator circuit: direct experimental observations

    NARCIS (Netherlands)

    Uranus, H.P.; Zhuang, L.; Roeloffzen, C.G.H.; Hoekstra, Hugo

    We report experimental observations of the negative-group-velocity (v_g) phenomenon in an integrated-optical two-port ring-resonator circuit. We demonstrate that when the v_g is negative, the (main) peak of output pulse appears earlier than the peak of a reference pulse, while for a positive v_g,

  6. DINS measurements on VESUVIO in the Resonance Detector configuration: proton mean kinetic energy in water

    Science.gov (United States)

    Pietropaolo, Antonino; Andreani, Carla; Filabozzi, Alessandra; Senesi, Roberto; Gorini, Giuseppe; Perelli-Cippo, Enrico; Tardocchi, Marco; Rhodes, Nigel J.; Schooneveld, Erik M.

    2006-04-01

    Deep Inelastic Neutron Scattering (DINS) measurements have been performed on a liquid water sample at two different temperatures and pressures. The experiments were carried out using the VESUVIO spectrometer at the ISIS spallation neutron source. This experiment represents the first DINS measurement from water using the Resonance Detector configuration, employing yttrium-aluminum-perovskite scintillator and a 238U analyzer foil. The maximum energy of the scattered neutrons was about 70 eV, allowing to access an extended kinematic space with energy and wave vector transfers at the proton recoil peak in the range 1 eV <= hbarω <= 20 eV and 25 Å-1 <= q <= 90 Å-1, respectively. Comparison with DINS measurements on water performed in the standard Resonance Filter configuration indicates the potential advantages offered by the use of Resonance Detector approach for DINS measurements at forward scattering angles.

  7. Resonant frequency and elastic modulus measurements on hardened cement pastes

    International Nuclear Information System (INIS)

    Lee, D.J.

    1982-12-01

    A new technique for measuring resonant frequency and elastic modulus is described. This has been used on specimens of hardened cement paste containing water with no simulated waste, and the results compared with measurements of ultrasonic pulse velocity, dimensional movements and compressive strength made on the same formulations. In addition, measurements were made on a specimen containing simulated waste which demonstrated the applicability of the new technique for following the development of the mechanical properties of cemented simulant radioactive waste in the laboratory. (U.K.)

  8. On the internal resonant modes in marching-on-in-time solution of the time domain electric field integral equation

    KAUST Repository

    Shi, Yifei; Bagci, Hakan; Lu, Mingyu

    2013-01-01

    Internal resonant modes are always observed in the marching-on-in-time (MOT) solution of the time domain electric field integral equation (EFIE), although 'relaxed initial conditions,' which are enforced at the beginning of time marching, should in theory prevent these spurious modes from appearing. It has been conjectured that, numerical errors built up during time marching establish the necessary initial conditions and induce the internal resonant modes. However, this conjecture has never been proved by systematic numerical experiments. Our numerical results in this communication demonstrate that, the internal resonant modes' amplitudes are indeed dictated by the numerical errors. Additionally, it is shown that in a few cases, the internal resonant modes can be made 'invisible' by significantly suppressing the numerical errors. These tests prove the conjecture that the internal resonant modes are induced by numerical errors when the time domain EFIE is solved by the MOT method. © 2013 IEEE.

  9. On the internal resonant modes in marching-on-in-time solution of the time domain electric field integral equation

    KAUST Repository

    Shi, Yifei

    2013-08-01

    Internal resonant modes are always observed in the marching-on-in-time (MOT) solution of the time domain electric field integral equation (EFIE), although \\'relaxed initial conditions,\\' which are enforced at the beginning of time marching, should in theory prevent these spurious modes from appearing. It has been conjectured that, numerical errors built up during time marching establish the necessary initial conditions and induce the internal resonant modes. However, this conjecture has never been proved by systematic numerical experiments. Our numerical results in this communication demonstrate that, the internal resonant modes\\' amplitudes are indeed dictated by the numerical errors. Additionally, it is shown that in a few cases, the internal resonant modes can be made \\'invisible\\' by significantly suppressing the numerical errors. These tests prove the conjecture that the internal resonant modes are induced by numerical errors when the time domain EFIE is solved by the MOT method. © 2013 IEEE.

  10. 1 million-Q optomechanical microdisk resonators for sensing with very large scale integration

    Science.gov (United States)

    Hermouet, M.; Sansa, M.; Banniard, L.; Fafin, A.; Gely, M.; Allain, P. E.; Santos, E. Gil; Favero, I.; Alava, T.; Jourdan, G.; Hentz, S.

    2018-02-01

    Cavity optomechanics have become a promising route towards the development of ultrasensitive sensors for a wide range of applications including mass, chemical and biological sensing. In this study, we demonstrate the potential of Very Large Scale Integration (VLSI) with state-of-the-art low-loss performance silicon optomechanical microdisks for sensing applications. We report microdisks exhibiting optical Whispering Gallery Modes (WGM) with 1 million quality factors, yielding high displacement sensitivity and strong coupling between optical WGMs and in-plane mechanical Radial Breathing Modes (RBM). Such high-Q microdisks with mechanical resonance frequencies in the 102 MHz range were fabricated on 200 mm wafers with Variable Shape Electron Beam lithography. Benefiting from ultrasensitive readout, their Brownian motion could be resolved with good Signal-to-Noise ratio at ambient pressure, as well as in liquid, despite high frequency operation and large fluidic damping: the mechanical quality factor reduced from few 103 in air to 10's in liquid, and the mechanical resonance frequency shifted down by a few percent. Proceeding one step further, we performed an all-optical operation of the resonators in air using a pump-probe scheme. Our results show our VLSI process is a viable approach for the next generation of sensors operating in vacuum, gas or liquid phase.

  11. Measurement of Resonance driving terms in the ATF Damping Ring

    CERN Document Server

    Tomás, R; Kuroda, S; Naito, T; Okugi, T; Urakawa, J; Zimmermann, F

    2008-01-01

    The measurement of resonance driving terms in the Damping Ring of the Accelerator Test Facility in KEK could help finding possible machine imperfections and even to optimize single particle stability through the minimization of non-linearities. The first experimental attempts of this enterprise are reported in this note.

  12. Actinide integral measurements in the CFRMF and integral tests for ENDF/B-V

    International Nuclear Information System (INIS)

    Anderl, R.A.

    1982-01-01

    Integral capture and/or fission rates have been reported earlier for several actinides irradiated in the fast neutron field of the Coupled Fast Reactivity Measurements Facility (CFRMF). These nuclides include 232 Th, 233 U, 235 U, 238 U, 237 Np, 239 Pu, 240 Pu, 242 Pu, 241 Am and 243 Am. This paper forucses on the utilization of these integral data for testing the respective cross sections on ENDF/B-V. Integral cross sections derived from the measured reaction rates are tabulated. Results are presented for cross-section data testing which includes integral testing based on a comparison of calculated and measured integral cross sections and testing based on least-squares-adjustment analyses

  13. One-Port Electronic Detection Strategies for Improving Sensitivity in Piezoelectric Resonant Sensor Measurements

    Directory of Open Access Journals (Sweden)

    Zhongxu Hu

    2016-10-01

    Full Text Available This paper describes a one-port mechanical resonance detection scheme utilized on a piezoelectric thin film driven silicon circular diaphragm resonator and discusses the limitations to such an approach in degenerate mode mass detection sensors. The sensor utilizes degenerated vibration modes of a radial symmetrical microstructure thereby providing both a sense and reference mode allowing for minimization of environmental effects on performance. The circular diaphragm resonator was fabricated with thickness of 4.5 µm and diameter of 140 µm. A PZT thin film of 0.75 µm was patterned on the top surface for the purposes of excitation and vibration sensing. The device showed a resonant frequency of 5.8 MHz for the (1, 1 mode. An electronic interface circuit was designed to cancel out the large static and parasitic capacitance allowing for electrical detection of the mechanical vibration thereby enabling the frequency split between the sense and reference mode to be measured accurately. The extracted motional current, proportional to the vibration velocity, was fed back to the drive to effectively increase the Q factor, and therefore device sensitivity, by more than a factor of 8. A software phase-locked loop was implemented to automatically track the resonant frequencies to allow for faster and accurate resonance detection. Results showed that by utilizing the absolute mode frequencies as an indication of sensor temperature, the variation in sensor temperature due to the heating from the drive electronics was accounted for and led to an ultimate measurement sensitivity of 2.3 Hz.

  14. One-Port Electronic Detection Strategies for Improving Sensitivity in Piezoelectric Resonant Sensor Measurements

    Science.gov (United States)

    Hu, Zhongxu; Hedley, John; Keegan, Neil; Spoors, Julia; Gallacher, Barry; McNeil, Calum

    2016-01-01

    This paper describes a one-port mechanical resonance detection scheme utilized on a piezoelectric thin film driven silicon circular diaphragm resonator and discusses the limitations to such an approach in degenerate mode mass detection sensors. The sensor utilizes degenerated vibration modes of a radial symmetrical microstructure thereby providing both a sense and reference mode allowing for minimization of environmental effects on performance. The circular diaphragm resonator was fabricated with thickness of 4.5 µm and diameter of 140 µm. A PZT thin film of 0.75 µm was patterned on the top surface for the purposes of excitation and vibration sensing. The device showed a resonant frequency of 5.8 MHz for the (1, 1) mode. An electronic interface circuit was designed to cancel out the large static and parasitic capacitance allowing for electrical detection of the mechanical vibration thereby enabling the frequency split between the sense and reference mode to be measured accurately. The extracted motional current, proportional to the vibration velocity, was fed back to the drive to effectively increase the Q factor, and therefore device sensitivity, by more than a factor of 8. A software phase-locked loop was implemented to automatically track the resonant frequencies to allow for faster and accurate resonance detection. Results showed that by utilizing the absolute mode frequencies as an indication of sensor temperature, the variation in sensor temperature due to the heating from the drive electronics was accounted for and led to an ultimate measurement sensitivity of 2.3 Hz. PMID:27792154

  15. Measured pulse width of sonoluminescence flashes in the form of resonance radiation

    Science.gov (United States)

    Giri, Asis; Arakeri, Vijay H.

    1998-09-01

    Recent studies have shown that the measured flash widths from single and multibubble sonoluminescence are in subnanosecond or even picosecond regime. Here, we provide conclusive evidence for the existence of nanosecond multibubble sonoluminescence. This has become possible by our ability to find a medium from which exclusive sodium D line resonance radiation as a form of sonoluminescence is possible. The measured flash width of this emission is found to be in the range of tens of nanoseconds and is sensitively dependent on experimental parameters. Our finding is important since all the earlier pulse width measurements have been limited to emission with the physical source or species responsible for observed optical radiation not being clearly identified. We propose that the presently observed resonance radiation is from ``soft'' bubble collapse as analyzed by V. Kamath et al. [J. Acoust. Soc. Am. 94, 248 (1993)].

  16. SILICON COMPATIBLE ACOUSTIC WAVE RESONATORS: DESIGN, FABRICATION AND PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Aliza Aini Md Ralib

    2014-12-01

    Full Text Available ABSTRACT: Continuous advancement in wireless technology and silicon microfabrication has fueled exciting growth in wireless products. The bulky size of discrete vibrating mechanical devices such as quartz crystals and surface acoustic wave resonators impedes the ultimate miniaturization of single-chip transceivers. Fabrication of acoustic wave resonators on silicon allows complete integration of a resonator with its accompanying circuitry.  Integration leads to enhanced performance, better functionality with reduced cost at large volume production. This paper compiles the state-of-the-art technology of silicon compatible acoustic resonators, which can be integrated with interface circuitry. Typical acoustic wave resonators are surface acoustic wave (SAW and bulk acoustic wave (BAW resonators.  Performance of the resonator is measured in terms of quality factor, resonance frequency and insertion loss. Selection of appropriate piezoelectric material is significant to ensure sufficient electromechanical coupling coefficient is produced to reduce the insertion loss. The insulating passive SiO2 layer acts as a low loss material and aims to increase the quality factor and temperature stability of the design. The integration technique also is influenced by the fabrication process and packaging.  Packageless structure using AlN as the additional isolation layer is proposed to protect the SAW device from the environment for high reliability. Advancement in miniaturization technology of silicon compatible acoustic wave resonators to realize a single chip transceiver system is still needed. ABSTRAK: Kemajuan yang berterusan dalam teknologi tanpa wayar dan silikon telah menguatkan pertumbuhan yang menarik dalam produk tanpa wayar. Saiz yang besar bagi peralatan mekanikal bergetar seperti kristal kuarza menghalang pengecilan untuk merealisasikan peranti cip. Silikon serasi  gelombang akustik resonator mempunyai potensi yang besar untuk menggantikan unsur

  17. Design and theoretical analysis of a resonant sensor for liquid density measurement.

    Science.gov (United States)

    Zheng, Dezhi; Shi, Jiying; Fan, Shangchun

    2012-01-01

    In order to increase the accuracy of on-line liquid density measurements, a sensor equipped with a tuning fork as the resonant sensitive component is designed in this paper. It is a quasi-digital sensor with simple structure and high precision. The sensor is based on resonance theory and composed of a sensitive unit and a closed-loop control unit, where the sensitive unit consists of the actuator, the resonant tuning fork and the detector and the closed-loop control unit comprises precondition circuit, digital signal processing and control unit, analog-to-digital converter and digital-to-analog converter. An approximate parameters model of the tuning fork is established and the impact of liquid density, position of the tuning fork, temperature and structural parameters on the natural frequency of the tuning fork are also analyzed. On this basis, a tuning fork liquid density measurement sensor is developed. In addition, experimental testing on the sensor has been carried out on standard calibration facilities under constant 20 °C, and the sensor coefficients are calibrated. The experimental results show that the repeatability error is about 0.03% and the accuracy is about 0.4 kg/m(3). The results also confirm that the method to increase the accuracy of liquid density measurement is feasible.

  18. Precision mass measurements using the Phase-Imaging Ion-Cyclotron-Resonance detection technique

    CERN Document Server

    Karthein, Jonas

    This thesis presents the implementation and improvement of the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) detection technique at the ISOLTRAP experiment, located at the ISOLDE / CERN, with the purpose of on-line high-precision and high-resolution mass spectrometry. Extensive simulation studies were performed with the aim of improving the phase-imaging resolution and finding the optimal position for detector placement. Following the outcome of these simulations, the detector was moved out of a region of electric-field distortion and closer to the center of the Penning trap, showing a dramatic improvement in the quality and reproducibility of the phase-imaging measurements. A new image reconstitution and analysis software for the MCP-PS detector was written in Python and ROOT and introduced in the framework of PI-ICR mass measurements. The state of the art in the field of time-of-flight ion-cyclotron-resonance measurements is illustrated through an analysis of on-line measurements of the mirror nuclei $...

  19. Simulated Performance of the Integrated Passive Neutron Albedo Reactivity and Self-Interrogation Neutron Resonance Densitometry Detector Designed for Spent Fuel Measurement at the Fugen Reactor in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Timothy J. II [Los Alamos National Laboratory; Lafleur, Adrienne M. [Los Alamos National Laboratory; Menlove, Howard O. [Los Alamos National Laboratory; Swinhoe, Martyn T. [Los Alamos National Laboratory; Tobin, Stephen J. [Los Alamos National Laboratory; Seya, Michio [Los Alamos National Laboratory; Bolind, Alan M. [Los Alamos National Laboratory

    2012-07-16

    An integrated nondestructive assay instrument, which combined the Passive Neutron Albedo Reactivity (PNAR) and the Self-Interrogation Neutron Resonance Densitometry (SINRD) techniques, is the research focus for a collaborative effort between Los Alamos National Laboratory (LANL) and the Japanese Atomic Energy Agency as part of the Next Generation Safeguard Initiative. We will quantify the anticipated performance of this experimental system in two physical environments: (1) At LANL we will measure fresh Low Enriched Uranium (LEU) assemblies for which the average enrichment can be varied from 0.2% to 3.2% and for which Gd laced rods will be included. (2) At Fugen we will measure spent Mixed Oxide (MOX-B) and LEU spent fuel assemblies from the heavy water moderated Fugen reactor. The MOX-B assemblies will vary in burnup from {approx}3 GWd/tHM to {approx}20 GWd/tHM while the LEU assemblies ({approx}1.9% initial enrichment) will vary from {approx}2 GWd/tHM to {approx}7 GWd/tHM. The estimated count rates will be calculated using MCNPX. These preliminary results will help the finalization of the hardware design and also serve a guide for the experiment. The hardware of the detector is expected to be fabricated in 2012 with measurements expected to take place in 2012 and 2013. This work is supported by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.

  20. As-Grown Gallium Nitride Nanowire Electromechanical Resonators

    Science.gov (United States)

    Montague, Joshua R.

    Technological development in recent years has led to a ubiquity of micro- and nano-scale electromechanical devices. Sensors for monitoring temperature, pressure, mass, etc., are now found in nearly all electronic devices at both the industrial and consumer levels. As has been true for integrated circuit electronics, these electromechanical devices have continued to be scaled down in size. For many nanometer-scale structures with large surface-to-volume ratio, dissipation (energy loss) becomes prohibitively large causing a decreasing sensitivity with decreasing sensor size. In this work, gallium nitride (GaN) nanowires are investigated as singly-clamped (cantilever) mechanical resonators with typical mechanical quality factors, Q (equal to the ratio of resonance frequency to peak full-width-at-half-maximum-power) and resonance frequencies, respectively, at or above 30,000, and near 1 MHz. These Q values---in vacuum at room temperature---indicate very low levels of dissipation; they are essentially the same as those for bulk quartz crystal resonators that form the basis of simple clocks and mass sensors. The GaN nanowires have lengths and diameters, respectively, of approximately 15 micrometers and hundreds of nanometers. As-grown GaN nanowire Q values are larger than other similarly-sized, bottom-up, cantilever resonators and this property makes them very attractive for use as resonant sensors. We demonstrate the capability of detecting sub-monolayer levels of atomic layer deposited (ALD) films, and the robust nature of the GaN nanowires structure that allows for their 'reuse' after removal of such layers. In addition to electron microscope-based measurement techniques, we demonstrate the successful capacitive detection of a single nanowire using microwave homodyne reflectometry. This technique is then extended to allow for simultaneous measurements of large ensembles of GaN nanowires on a single sample, providing statistical information about the distribution of

  1. Longitudinal and transverse electric field measurements in resonant cavities

    International Nuclear Information System (INIS)

    Tong Dechun; Chen Linfeng; Zheng Xiaoyue

    1994-01-01

    The paper presents a measuring technique for the electric field distribution of high order modes in resonant cavities. A perturbing bead-like cage made with metallic wires are developed for S-band field measurements, which can be used to detect a small electric field component in the presence of other strong electric or magnetic field components (That means high sensitivity and high directivity). In order to avoid orientation error for the cage with very high directivity, two parallel threads were used for supporting the perturbing cage. A simple mechanical set-up is described. The cage can be driven into the cavity on-axis or off-axis in any azimuth for the longitudinal and transverse electric field measurements

  2. Optical micro-bubble resonators as promising biosensors

    Science.gov (United States)

    Giannetti, A.; Barucci, A.; Berneschi, S.; Cosci, A.; Cosi, F.; Farnesi, D.; Nunzi Conti, G.; Pelli, S.; Soria, S.; Tombelli, S.; Trono, C.; Righini, G. C.; Baldini, F.

    2015-05-01

    Recently, optical micro-bubble resonators (OMBRs) have gained an increasing interest in many fields of photonics thanks to their particular properties. These hollow microstructures can be suitable for the realization of label - free optical biosensors by combining the whispering gallery mode (WGM) resonator properties with the intrinsic capability of integrated microfluidics. In fact, the WGMs are morphology-dependent modes: any change on the OMBR inner surface (due to chemical and/or biochemical binding) causes a shift of the resonance position and reduces the Q factor value of the cavity. By measuring this shift, it is possible to obtain information on the concentration of the analyte to be detected. A crucial step for the development of an OMBR-based biosensor is constituted by the functionalization of its inner surface. In this work we report on the development of a physical and chemical process able to guarantee a good homogeneity of the deposed bio-layer and, contemporary, to preserve a high quality factor Q of the cavity. The OMBR capability of working as bioassay was proved by different optical techniques, such as the real time measurement of the resonance broadening after each functionalization step and fluorescence microscopy.

  3. Neutron resonances in the compound nucleus: Parity nonconservation to dynamic temperature measurements

    International Nuclear Information System (INIS)

    Yuan, V.W.

    1997-08-01

    Experiments using epithermal neutrons that interact to form compound-nuclear resonances serve a wide range of scientific applications. Changes in transmission which are correlated to polarization reversal in incident neutrons have been used to study parity nonconservation in the compound nucleus for a wide range of targets. The ensemble of measured parity asymmetries provides statistical information for the extraction of the rms parity-violating mean-square matrix element as a function of mass. Parity nonconservation in neutron resonances can also be used to determine the polarization of neutron beams. Finally the motion of target atoms results in an observed temperature-dependent Doppler broadening of resonance line widths. This broadening can be used to determine temperatures on a fast time scale of one microsecond or less

  4. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  5. Grid Based Integration Technologies of Virtual Measurement System

    International Nuclear Information System (INIS)

    Zhang, D P; He, L S; Yang, H

    2006-01-01

    This paper presents a novel integrated architecture of measurement system for the new requirements of measurement collaboration, measurement resource interconnection and transparent access etc in the wide-area and across organization in the context of a grid. The complexity of integration on a grid arises from the scale, dynamism, autonomy, and distribution of the measurement resources. The main argument of this paper is that these complexities should be made transparent to the collaborative measurement, via flexible reconfigurable mechanisms and dynamic virtualization services. The paper is started by discussing the integration-oriented measurement architecture which provides collaborative measurement services to distributed measurement resources and then the measurement mechanisms are discussed which implements the transparent access and collaboration of measurement resources by providing protocols, measurement schedule and global data driven model

  6. Nanocantilever based mass sensor integrated with cmos circuitry

    DEFF Research Database (Denmark)

    Davis, Zachary James; Abadal, G.; Campabadal, F.

    2003-01-01

    We have demonstrated the successful integration of a cantilever based mass detector with standard CMOS circuitry. The purpose of the circuitry is to facilitate the readout of the cantilever's deflection in order to measure resonant frequency shifts of the cantilever. The principle and design...... of the mass detector are presented showing that miniaturization of such cantilever based resonant devices leads to highly sensitive mass sensors, which have the potential to detect single molecules. The design of the readout circuitry used for the first electrical characterization of an integrated cantilever...... with CMOS circuitry is demonstrated. The electrical characterization of the device shows that the resonant behavior of the cantilever depends on the applied voltages, which corresponds to theory....

  7. New design of a triplexer using ring resonator integrated with directional coupler based on photonic crystals

    Science.gov (United States)

    Wu, Yaw-Dong; Shih, Tien-Tsorng; Lee, Jian-Jang

    2009-11-01

    In this paper, we proposed the design of directional coupler integrated with ring resonator based on two-dimensional photonic crystals (2D PCs) to develop a triplexer filter. It can be widely used as the fiber access network element for multiplexer-demultiplexer wavelength selective in fiber-to-the-home (FTTH) communication systems. The directional coupler is chosen to separate the wavelengths of 1490nm and 1310nm. The ring resonator separates the wavelength of 1550nm. The transmission efficiency is larger than 90%. Besides, the total size of propose triplexer is only 19μm×12μm. We present simulation results using the finite-difference time-domain (FDTD) method for the proposed structure.

  8. Precision electroweak measurements on the $Z$ resonance

    CERN Document Server

    Schael, S; Brunelière, R; Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Jézéquel, S; Lees, J P; Lucotte, A; Martin, F; Merle, E; Minard, M N; Nief, J Y; Odier, P; Pietrzyk, B; Trocmé, B; Bravo, S; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Orteu, S; Pacheco, A; Park, I C; Perlas, J; Riu, I; Ruiz, H; Sánchez, F; Colaleo, A; Creanza, D; De Filippis, N; De Palma, M; Iaselli, G; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Bazarko, A; Becker, U; Boix, G; Bird, F; Blucher, E; Bonvicini, B; Bright-Thomas, P; Barklow, T; Cattaneo, M; Cerutti, F; Clerbaux, B; Drevermann, H; Forty, R W; Frank, M; Greening, T C; Hagelberg, R; Halley, A W; Gianotti, F; Girone, M; Hansen, J B; Harvey, J; Jacobsen, R; Hutchcroft, D E; Janot, P; Jost, B; Knobloch, J; Kado, M; Lehraus, Ivan; Lazeyras, Pierre; Maley, P; Mato, P; May, J; Moutoussi, A; Pepé-Altarelli, M; Ranjard, F; Rolandi, Luigi; Schlatter, W D; Schmitt, B; Schneider, O; Tejessy, W; Teubert, F; Tomalin, I R; Tournefier, E; Veenhof, R; Valassi, A; Wiedenmann, W; Wright, A E; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Dessagne, S; Falvard, A; Ferdi, C; Fayolle, D; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Pascolo, J M; Perret, P; Podlyski, F; Bertelsen, H; Fernley, T; Hansen, J D; Hansen, J R; Hansen, P H; Kraan, A C; Lindahl, A; Møllerud, R; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, E; Siotis, I; Vayaki, A; Blondel, A; Bonneaud, G; Brient, J C; Machefert, F; Rougé, A; Rumpf, M; Swynghedauw, M; Tanaka, R; Verderi, M; Videau, H L; Ciulli, V; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Antonelli, A; Antonelli, M; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, G P; Passalacqua, L; Picchi, P; Colrain, P; ten Have, I; Hughes, I S; Kennedy, J; Knowles, I G; Lynch, J G; Morton, W T; Negus, P; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Thompson, A S; Turnbull, R M; Wasserbaech, S R; Buchmüller, O L; Cavanaugh, R J; Dhamotharan, S; Geweniger, C; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, W; Wunsch, M; Beuselinck, R; Binnie, D M; Cameron, W; Davies, G; Dornan, P J; Goodsir, S M; Marinelli, N; Martin, E; Nash, J; Nowell, J; Rutherford, S A; Sedgbeer, J K; Thompson, J C; White, R; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bouhova-Thacker, E; Bowdery, C K; Buck, P G; Clarke, D P; Ellis, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Keemer, N R; Pearson, M R; Robertson, N A; Sloan, T; Smizanska, M; Snow, S W; Williams, M I; van der Aa, O; Delaere, C; Leibenguth, G; Lemaître, V; Bauerdick, L A T; Blumenschein, U; Van Gemmeren, P; Giehl, I; Hölldorfer, F; Jakobs, K; Kasemann, M; Kayser, F; Kleinknecht, K; Müller, A S; Quast, G; Renk, B; Rohne, E; Sander, H G; Schmeling, S; Wachsmuth, H W; Wanke, R; Zeitnitz, C; Ziegler, T; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Carr, J; Coyle, P; Curtil, C; Ealet, A; Etienne, F; Fouchez, D; Motsch, F; Payre, P; Rousseau, D; Talby, M; Thulasidas, M; Aleppo, M; Ragusa, F; Büscher, V; David, A; Dietl, H; Ganis, G; Hüttmann, K; Lütjens, G; Mannert, C; Männer, W; Moser, H G; Settles, R; Seywerd, H; Stenzel, H; Villegas, M; Wolf, G; Boucrot, J; Callot, O; Chen, S; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacholkowska, A; Le Diberder, F R; Lefrançois, J; Mutz, A M; Schune, M H; Serin, L; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Bettarini, S; Boccali, T; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Giammanco, A; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, F; Rizzo, G; Sanguinetti, G; Sciabà, A; Sguazzoni, G; Spagnolo, P; Steinberger, J; Tenchini, R; Vannini, C; Venturi, A; Verdini, P G; Awunor, O; Blair, G A; Cowan, G; García-Bellido, A; Green, M G; Medcalf, T; Strong, J A; Teixeira-Dias, P; Botterill, David R; Clifft, R W; Edgecock, T R; Edwards, M; Haywood, S J; Norton, P R; Ward, J J; Bloch-Devaux, B; Boumediene, D E; Colas, P; Emery, S; Fabbro, B; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Tuchming, B; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Cartwright, S; Combley, F; Hodgson, P N; Lehto, M H; Thompson, L F; Affholderbach, K; Barberio, E; Böhrer, A; Brandt, S; Burkhardt, H; Feigl, E; Grupen, C; Hess, J; Lutters, G; Meinhard, H; Minguet-Rodríguez, J A; Mirabito, L; Misiejuk, A; Neugebauer, E; Ngac, A; Prange, G; Rivera, F; Saraiva, P; Schäfer, U; Sieler, U; Smolik, L; Stephan, F; Trier, H; Apollonio, M; Borean, C; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pitis, L; He, H; Kim, H; Pütz, J; Rothberg, J E; Armstrong, S R; Bellantoni, L; Berkelman, K; Cinabro, D; Conway, J S; Cranmer, K; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; Jin, S; Johnson, R P; Kile, J; McNamara, P A; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Sharma, V; Walsh, A M; Walsh, J; Wear, J; Von Wimmersperg-Töller, J H; Wu, J; Wu, S L; Wu, X; Yamartino, J M; Zobernig, G; Dissertori, G; Abdallah, J; Abreu, P; Adam, W; Adye, T; Adzic, P; Ajinenko, I; Albrecht, T; Alderweireld, T; Alekseev, G D; Alemany-Fernandez, R; Allmendinger, T; Allport, P P; Almehed, S; Amaldi, Ugo; Amapane, N; Amato, S; Anashkin, E; Anassontzis, E G; Andersson, P; Andreazza, A; Andringa, S; Anjos, N; Antilogus, P; Apel, W D; Arnoud, Y; Ask, S; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Ballestrero, A; Bambade, P; Barão, F; Barbiellini, G; Barbier, R; Bardin, D; Barker, G; Baroncelli, A; Battaglia, M; Baubillier, M; Becks, K H; Begalli, M; Behrmann, A; Beillière, P; Belokopytov, Yu A; Belous, K S; Ben-Haim, E; Benekos, N; Benvenuti, A C; Bérat, C; Berggren, M; Berntzon, L; Bertini, D; Bertrand, D; Besançon, M; Besson, N; Bianchi, F; Bigi, M; Bilenky, S M; Bizouard, M A; Bloch, D; Blom, M; Bluj, M; Bonesini, M; Bonivento, W; Boonekamp, M; Booth, P S L; Borgland, A W; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Boyko, I; Bozovic, I; Bozzo, M; Bracko, M; Branchini, P; Brenke, T; Brenner, R; Brodet, E; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschbeck, Brigitte; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Carena, F; Carroll, L; Caso, C; Castillo-Gimenez, M V; Castro, N; Cattai, A; Cavallo, F; Chabaud, V; Chapkin, M; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Shlyapnikov, P; Chochula, P; Chorowicz, V; Chudoba, J; Chung, S U; Cieslik, K; Collins, P; Colomer, M; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Costa, M J; Cowell, J H; Crawley, H B; Crennell, D J; Crépé, S; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Hondt, J; D'Almagne, B; Dalmau, J; Damgaard, G; Davenport, M; Da Silva, T; Da Silva, W; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; De Lotto, B; De Maria, N; De Min, A; De Paula, L; Dijkstra, H; Di Ciaccio, L; Di Diodato, A; Di Simone, A; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Duperrin, A; Durand, J D; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, G; Ellert, M; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fanourakis, G K; Fassouliotis, D; Fayot, J; Feindt, M; Fenyuk, A; Fernández, J; Ferrari, P; Ferrer, A; Ferrer-Ribas, E; Ferro, F; Fichet, S; Firestone, A; Fischer, P A; Flagmeyer, U; Föth, H; Fokitis, E; Fontanelli, F; Franek, B; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J; Galloni, A; Gamba, D; Gamblin, S; Gandelman, M; García, C; García, J; Gaspar, C; Gaspar, M; Gasparini, U; Gavillet, P; Gazis, E; Gelé, D; Gerber, J P; Gerdyukov, L N; Ghodbane, N; Gil, I; Glege, F; Gokieli, R; Golob, B; Gómez-Ceballos, G; Gonçalves, P; González-Caballero, I; Gopal, G; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Green, C; Grefrath, A; Grimm, H J; Gris, P; Grosdidier, G; Grzelak, K; Günther, M; Guy, J; Haag, C; Hahn, F; Hahn, S; Haider, S; Hallgren, A; Hamacher, K; Hamilton, K; Hansen, J; Harris, F J; Haug, S; Hauler, F; Hedberg, V; Heising, S; Hennecke, M; Henriques, R; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Hoffman, J; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huber, M; Huet, K; Hughes, G J; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Jeans, D; Johansson, E K; Johansson, P D; Jonsson, P; Joram, C; Juillot, P; Jungermann, L; Kapusta, F; Karafasoulis, K; Katsanevas, S; Katsoufis, E C; Keränen, R; Kernel, G; Kersevan, B P; Kerzel, U; Khomenko, B A; Khovanskii, N N; Kiiskinen, A P; King, B T; Kinvig, A; Kjaer, N J; Klapp, O; Klein, H; Kluit, P; Knoblauch, D; Kokkinias, P; Konoplyannikov, A K; Koratzinos, M; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, M; Kreuter, C; Kriznic, E; Krstic, J; Krumshtein, Z; Kubinec, P; Kucewicz, W; Kucharczyk, M; Kurowska, J; Kurvinen, K; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Laugier, J P; Lauhakangas, R; Leder, G; Ledroit, F; Lefébure, V; Leinonen, L; Leisos, A; Leitner, R; Lemonne, J; Lenzen, G; Lepeltier, V; Lesiak, T; Lethuillier, M; Libby, J; Liebig, W; Liko, D; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; Lopes, J H; López, J M; López-Fernandez, R; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J; Mahon, J R; Maio, A; Malek, A; Malmgren, T G M; Maltezos, S; Malychev, V; Mandl, F; Marco, J; Marco, R; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Masik, J; Mastroyiannopoulos, N; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, F; Mazzucato, M; McCubbin, M; McKay, R; McNulty, R; McPherson, G; Meroni, C; Meyer, W T; Myagkov, A; Migliore, E; Mitaroff, W A; Mjörnmark, U; Moa, T; Moch, M; Møller, R; Mönig, K; Monge, R; Montenegro, J; Moraes, D; Moreau, X; Moreno, S; Morettini, P; Morton, G; Müller, U; Münich, K; Mulders, M; Mulet-Marquis, C; Mundim, L; Muresan, R; Murray, W; Muryn, B; Myatt, G; Myklebust, T; Naraghi, F; Nassiakou, M; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Neufeld, N; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Niezurawski, P; Nikolaenko, V; Nikolenko, M; Nomokonov, V P; Normand, A; Nygren, A; Oblakowska-Mucha, A; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, R; Orazi, G; Österberg, K; Ouraou, A; Oyanguren, A; Paganini, P; Paganoni, M; Paiano, S; Pain, R; Paiva, R; Palacios, J P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Passon, O; Pavel, T; Pegoraro, M; Peralta, L; Perepelitsa, V F; Pernicka, M; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Piedra, J; Pieri, L; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Poireau, V; Pol, M E; Polok, G; Polycarpo, E; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, A; Radojicic, D; Ragazzi, S; Rahmani, H; Rakoczy, D; Rames, J; Ramler, L; Ratoff, P N; Read, A; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Rehn, J; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Rídky, J; Rinaudo, G; Ripp-Baudot, I; Rivero, M; Rodríguez, D; Rohne, O; Romero, A; Ronchese, P; Rosenberg, E I; Rosinsky, P; Roudeau, P; Rovelli, T; Royon, C; Ruhlmann-Kleider, V; Ruiz, A; Ryabtchikov, D; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salmi, L; Salt, J; Sampsonidis, D; Sannino, M; Savoy-Navarro, A; Scheidle, T; Schneider, H; Schwemling, P; Schwering, B; Schwickerath, U; Schyns, M A E; Scuri, F; Seager, P; Sedykh, Yu; Segar, A; Seibert, N; Sekulin, R L; Shellard, R C; Sheridan, A; Siebel, M; Silvestre, R; Simard, L; Simonetto, F; Sisakian, A; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O; Smith, G R; Sokolov, A; Sopczak, A; Sosnowski, R; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stanitzki, M; Stapnes, S; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Szumlak, T; Tabarelli de Fatis, T; Taffard, A C; Tegenfeldt, F; Terranova, F; Thomas, J; Tilquin, A; Timmermans, J; Tinti, N; Tkatchev, L G; Tobin, M; Todorov, T; Todorovova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tortosa, P; Tranströmer, G; Travnicek, P; Treille, D; Tristram, G; Trochimczuk, M; Trombini, A; Troncon, C; Tsirou, A; Turluer, M L; Tyapkin, I A; Tyapkin, P; Tzamarias, S; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van den Boeck, W; Van Doninck, W K; Van Eldik, J; Van Lysebetten, A; Van Remortel, N; Van Vulpen, I; Vassilopoulos, N; Vegni, G; Veloso, F; Ventura, L; Venus, W; Verbeure, F; Verdier, P; Verlato, M; Vertogradov, L S; Verzi, V; Vilanova, D; Vitale, L; Vlasov, E; Vodopyanov, A S; Vollmer, C; Voulgaris, G; Vrba, V; Wahlen, H; Walck, C; Washbrook, A J; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J; Wilkinson, G; Winter, M; Witek, M; Wlodek, T; Yi, J; Yushchenko, O P; Zaitsev, A; Zalewska-Bak, A; Zalewski, P; Zavrtanik, D; Zevgolatakos, E; Zhuravlov, V; Zimin, N I; Zintchenko, A; Zoller, P; Zucchelli, G C; Zumerle, G; Zupan, M; Acciarri, M; Achard, P; Adriani, O; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Balandras, A; Baldew, S V; Ball, R C; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Barone, L; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, G J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, M; Braccini, S; Branson, J G; Brigljevic, V; Brochu, F; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Button, A J; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Cesaroni, F; Chamizo-Llatas, M; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, L; Cindolo, F; Civinini, C; Clare, I; Clare, R; Coignet, G; Colijn, A P; Colino, N; Costantini, S; Cotorobai, F; Cozzoni, B; de la Cruz, B; Csilling, A; Cucciarelli, S; Dai, T S; van Dalen, J A; D'Alessandro, R; De Asmundis, R; Debreczeni, J; Deglon, P; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, M; Dominguez, A; Doria, A; Dova, M T; Duchesneau, D; Dufournaud, D; Duda, M; Duinker, P; Durán, I; Dutta, S; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Extermann, P; Fabre, M; Faccini, R; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Fisk, I; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gau, S S; Gentile, S; Gheordanescu, N; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; van Gulik, R; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hidas, P; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hoorani, H; Hou, S R; Iashvili, I; Innocente, V; Jin, B N; Jindal, P; Jones, L W; de Jong, P; Josa-Mutuberria, I; Khan, R A; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Koffeman, E; Kopal, M; Kopp, A; Koutsenko, V F; Kraber, M; Krämer, R W; Krenz, W; Krüger, A; Kuijten, H; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lassila-Perini, K M; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee, H J; Le Goff, J M; Leiste, R; Leonardi, E; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Lu, W; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lugnier, L; Lustermann, W; Ma, W G; Maity, M; Malgeri, L; Malinin, A; Maña, C; Mangeol, D J J; Mans, J; Marchesini, P A; Marian, G; Martin, J P; Marzano, F; Massaro, G G G; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Merk, M; Meschini, M; Metzger, W J; Von der Mey, M; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Molnár, P; Monteleoni, B; Moulik, T; Muanza, G S; Muheim, F; Muijs, A J M; Musicar, B; Musy, M; Nagy, S; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Niessen, T; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Oulianov, A; Pal, I; Palomares, C; Pandoulas, D; Paoletti, S; Paoloni, A; Paolucci, P; Paramatti, R; Park, H K; Park, I H; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, F; Peach, D; Pedace, M; Pensotti, S; Perret-Gallix, D; Petersen, B; Piccolo, D; Pierella, F; Pieri, M; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Pothier, J; Produit, N; Prokofiev, D O; Prokofev, D; Quartieri, J; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riles, K; Robohm, A; Rodin, J; Roe, B P; Romero, L; Rosca, A; Rosemann, C; Rosenbleck, C; Rosier-Lees, S; Roth, S; Rubio, J A; Ruggiero, G; Ruschmeier, D; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Sanders, M P; Sarakinos, M E; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schopper, Herwig Franz; Schotanus, D J; Schwering, G; Sciacca, C; Sciarrino, D; Seganti, A; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A; Siedenburg, T; Son, D; Smith, B; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stone, A; Stone, H; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Szillási, Z; Sztaricskai, T; Tang, X W; Tarjan, P; Tauscher, L; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Uchida, Y; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vásquez, R; Veszpremi, V; Vesztergombi, G; Vetlitskii, I; Vicinanza, D; Viertel, G; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, Q; Wang, X L; Wang, Z M; Weber, A; Weber, M; Wienemann, P; Wilkens, H; Wu, S X; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zilizi, G; Zimmermann, B; Zöller, M; Abbiendi, G; Ainsley, C; Åkesson, P F; Alexander, G; Allison, J; Altekamp, N; Amaral, P; Ametewee, K A; Anagnostou, G; Anderson, K J; Anderson, S; Arcelli, S; Armitage, J C; Asai, S; Ashby, S F; Ashton, P; Astbury, A; Axen, D; Azuelos, Georges; Bahan, G A; Bailey, I; Baines, J T M; Ball, A H; Banks, J; Barillari, T; Barker, G J; Barlow, R J; Barnett, S; Bartoldus, R; Batley, J Richard; Beaudoin, G; Bechtle, P; Bechtluft, J; Beck, A; Becker, J; Beeston, C; Behnke, T; Bell, A N; Bell, K W; Bell, P J; Bella, G; Bellerive, A; Benelli, G; Bentvelsen, Stanislaus Cornelius Maria; Berlich, P; Bethke, Siegfried; Biebel, O; Binder, U; Blobel, Volker; Bloodworth, Ian J; Bloomer, J E; Bock, P; Boden, B; Böhme, J; Boeriu, O; Bonacorsi, D; Bosch, H M; Bougerolle, S; Boutemeur, M; Bouwens, B T; Brabson, B B; Braibant, S; Breuker, H; Brigliadori, L; Brown, R M; Brun, R; Bürgin, R; Büsser, K; Burckhart, H J; Burgard, C; Cammin, J; Campana, S; Capiluppi, P; Carnegie, R K; Caron, B; Carter, A A; Carter, J R; Chang, C Y; Charlesworth, C; Charlton, D G; Chrin, J T M; Chrisman, D; Chu, S L; Ciocca, C; Clarke, P E L; Clay, E; Clayton, J C; Cohen, I; Collins, W J; Conboy, J E; Cooke, O C; Cooper, M; Couch, M; Couchman, J; Coupland, M; do Couto e Silva, E; Coxe, R L; Cuffiani, M; Dado, S; Dallapiccola, C; Dallavalle, G M; Dallison, S; Darling, C; De Jong, S; de Roeck, A; De Wolf, E A; Debu, P; Deng, H; Deninno, M M; Dervan, P; Desch, Klaus; Dieckmann, A; Dienes, B; Dixit, M S; Donkers, M; Doucet, M; Dubbert, J; Duchovni, E; Duckeck, G; Duerdoth, I P; Dumas, D J P; Eckerlin, G; Edwards, J E G; Elcombe, P A; Estabrooks, P G; Evans, H G; Evans, M; Fabbri, F; Fanti, M; Fath, P; Feld, L; Fiedler, F; Fierro, M; Fincke-Keeler, M; Fischer, H M; Fleck, I; Folman, R; Fong, D G; Ford, M; Foucher, M; Frey, A; Fürtjes, A; Fukui, H; Fukunaga, C; Futyan, D I; Gagnon, P; Gaidot, A; Ganel, O; Gary, J W; Gascon, J; Gascon-Shotkin, S M; Gaycken, G; Geddes, N I; Geich-Gimbel, C; Gensler, S W; Gentit, F X; Geralis, T; Giacomelli, G; Giacomelli, P; Giacomelli, R; Gibson, V; Gibson, W R; Gillies, James D; Gingrich, D M; Giunta, M; Glenzinski, D A; Goldberg, J; Goodrick, M J; Gorn, W; Graham, K; Grandi, C; Grant, F C; Gross, E; Grunhaus, Jacob; Gruwé, M; Günther, P O; Sen-Gupta, A; Hagemann, J; Hajdu, C; Hamann, M; Hanson, G G; Hansroul, M; Hapke, M; Harder, K; Harel, A; Hargrove, C K; Harin-Dirac, M; Harrison, P F; Hart, P A; Hartmann, C; Hattersley, P M; Hauschild, M; Hawkes, C M; Hawkings, R; Heflin, E; Hemingway, R J; Hensel, C; Herten, G; Heuer, R D; Hill, J C; Hillier, S J; Hilse, T; Hinshaw, D A; Ho, C; Hoare, J; Hobbs, J D; Hobson, P R; Hochman, D; Höcker, Andreas; Hoffman, K; Holl, B; Homer, R J; Honma, A K; Horváth, D; Hossain, K R; Howard, R; Howarth, C P; Hüntemeyer, P; Hughes-Jones, R E; Humbert, R; Igo-Kemenes, P; Ihssen, H; Imrie, D C; Ingram, M R; Ishii, K; Jacob, F R; Janissen, A C; Jawahery, A; Jeffreys, P W; Jeremie, H; Jimack, M; Jobes, M; Joly, A; Jones, C R; Jones, G; Jones, M; Jost, U; Jovanovic, P; Jui, C; Kanaya, N; Kanzaki, J; Karapetian, G V; Karlen, D; Kartvelishvili, V G; Kawagoe, K; Kawamoto, T; Keeler, R K; Kellogg, R G; Kennedy, B W; Kim, D H; King, B J; Kirk, J; Klein, K; Kleinwort, C; Klem, D E; Klier, A; Kluth, S; Kobayashi, T; Kobel, M; Köpke, L; Koetke, D S; Kokott, T P; Komamiya, S; Kormos, L; Kowalewski, R V; Kramer, T; Kral, J F; Kress, T; Kreutzmann, H; Krieger, P; Von Krogh, J; Kroll, J; Krop, D; Krüger, K; Kühl, T; Kupper, M; Kuwano, M; Kyberd, P; Lafferty, G D; Lafoux, H; Lahmann, R; Lai, W P; Lamarche, F; Landsman, H; Lanske, D; Larson, W J; Lauber, J; Lautenschlager, S R; Lawson, I; Layter, J G; Lazic, D; Le Dû, P; Leblanc, P; Lee, A M; Lefebvre, E; Leins, A; Lellouch, D; Lennert, P; Leroy, C; Lessard, L; Letts, J; Levegrün, S; Levinson, L; Lewis, C; Liebisch, R; Lillich, J; Littlewood, C; Lloyd, A W; Lloyd, S L; Loebinger, F K; Long, G D; Lorah, J M; Lorazo, B; Losty, Michael J; Lou, X C; Lü, J; Ludwig, A; Ludwig, J; Luig, A; Macchiolo, A; MacPherson, A; Mader, W; Mättig, P; Malik, A; Mannelli, M; Marcellini, S; Marchant, T E; Maringer, G; Markus, C; Martin, A J; Martínez, G; Masetti, G; Mashimo, T; Matthews, W; Maur, U; McDonald, W J; McGowan, R F; McKenna, J; McKigney, E A; McMahon, T J; McNab, A I; McNutt, J R; McPherson, A C; McPherson, R A; Meijers, F; Méndez-Lorenzo, P; Menges, W; Menke, S; Menszner, D; Merritt, F S; Mes, H; Meyer, J; Meyer, N; Michelini, A; Middleton, R P; Mihara, S; Mikenberg, G; Mildenberger, J; Miller, D J; Milstene, C; Mir, R; Moed, S; Mohr, W; Moisan, C; Montanari, A; Mori, T; Moss, M W; Mouthuy, T; Murphy, P G; Mutter, A; Nagai, K; Nakamura, I; Nanjo, H; Neal, H A; Nellen, B; Nguyen, H H; Nijjhar, B; Nisius, R; Nozaki, M; Oakham, F G; Odorici, F; Ogg, M; Ögren, H O; Oh, A; Oh, H; Okpara, A; Oldershaw, N J; Omori, T; O'Neale, S W; O'Neill, B P; Oram, C J; Oreglia, M J; Orito, S; Pahl, C; Pálinkás, J; Palmonari, F; Pansart, J P; Panzer-Steindel, B; Paschievici, P; Pásztor, G; Pater, J R; Patrick, G N; Pawley, S J; Paz-Jaoshvili, N; Pearce, M J; Petzold, S; Pfeifenschneider, P; Pfister, P; Pilcher, J E; Pinfold, J L; Pitman, D; Plane, D E; Poffenberger, P R; Poli, B; Polok, J; Pooth, O; Posthaus, A; Pouladdej, A; del Pozo, L A; Prebys, E; Pritchard, T W; Przybycien, M B; Przysiezniak, H; Quadt, A; Rabbertz, K; Raith, B; Redmond, M W; Rees, D L; Rembser, C; Renkel, P; Richards, G E; Rick, H; Rigby, D; Robins, S A; Robinson, D; Rodning, N; Rollnik, A; Roney, J M; Rooke, A M; Ros, E; Rosati, S; Roscoe, K; Rossberg, S; Rossi, A M; Rosvick, M; Routenburg, P; Rozen, Y; Runge, K; Runólfsson, O; Ruppel, U; Rust, D R; Rylko, R; Sachs, K; Saeki, T; Sahr, O; Sanghera, S; Sarkisyan-Grinbaum, E; Sasaki, M; Sbarra, C; Schaile, A D; Schaile, O; Schappert, W; Scharf, F; Scharff-Hansen, P; Schenk, P; Schieck, J; von der Schmitt, H; Schmitt, S; Schörner-Sadenius, T; Schreiber, S; Schröder, M; Schütz, P; Schultz-Coulon, H C; Schulz, M; Schumacher, M; Schwarz, J; Schwick, C; Scott, W G; Settles, M; Seuster, R; Shears, T G; Shen, B C; Shepherd-Themistocleous, C H; Sherwood, P; Shypit, R; Simon, A; Singh, P; Siroli, G P; Sittler, A; Skillman, A; Skuja, A; Smith, A M; Smith, T J; Snow, G A; Sobie, R J; Söldner-Rembold, S; Spagnolo, S; Spanó, F; Springer, R W; Sproston, M; Starks, M; Steiert, M; Stephens, K; Steuerer, J; Stier, H E; Stockhausen, B; Stoll, K; Ströhmer, R; Strom, D; Strumia, F; Stumpf, L; Surrow, B; Szymanski, P; Tafirout, R; Takeda, H; Takeshita, T; Talbot, S D; Tanaka, S; Taras, P; Tarem, S; Tasevsky, M; Taylor, R J; Tecchio, M; Tesch, N; Teuscher, R; Thackray, N J; Thiergen, M; Thomson, M A; Von Törne, E; Towers, S; Toya, D; Trócsányi, Z L; Tran, P; Trefzger, T; Tresilian, N J; Trigger, I; Tscheulin, M; Tsukamoto, T; Tsur, E; Turcot, A S; Turner-Watson, M F; Tysarczyk-Niemeyer, G; Ueda, I; Ujvári, B; Utzat, P; Vachon, B; Van den Plas, D; Van Kooten, R; VanDalen, G J; Vannerem, P; Vasseur, G; Vertesi, R; Verzocchi, M; Vikas, P; Vincter, M G; Virtue, C J; Vokurka, E H; Vollmer, C F; Voss, H; Vossebeld, Joost Herman; Wäckerle, F; Wagner, A; Wagner, D L; Wahl, C; Walker, J P; Waller, D; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Weber, P; Weisz, S; Wells, P S; Wengler, T; Wermes, N; Wetterling, D; Weymann, M; Whalley, M A; White, J S; Wilkens, B; Wilson, J A; Wilson, G W; Wingerter, Isabelle; Winterer, V H; Wood, N C; Wotton, S; Wyatt, T R; Yaari, R; Yamashita, S; Yang, Y; Yeaman, A; Yekutieli, G; Yurko, M; Zacek, V; Zacharov, I E; Zer-Zion, D; Zeuner, W; Zivkovic, L; Zorn, G T; Abe, Kenji; Abe, Koya; Abe, T; Abt, I; Acton, P D; Adam, I; Agnew, G; Akagi, T; Akimoto, H; Allen, N J; Ash, W W; Aston, D; Bacchetta, N; Baird, K G; Baltay, C; Band, H R; Barakat, M B; Baranko, G J; Bardon, O; Barklow, T L; Bashindzhagian, G L; Bauer, J M; Bazarko, A O; Bean, A; Bellodi, G; Ben-David, R; Berger, R; Bienz, T; Bilei, G M; Bisello, D; Blaylock, G; Bogart, J R; Bolen, B; Bolton, T; Bower, G R; Brau, J E; Breidenbach, M; Bugg, W M; Burke, D; Burnett, T H; Burrows, P N; Busza, W; Calcaterra, A; Caldwell, D O; Camanzi, B; Carpinelli, M; Cassell, R; Castaldi, R; Castro, A; Cavalli-Sforza, M; Chadwick, George B; Chou, A; Church, E; Claus, R; Cohn, H O; Coller, J A; Convery, M R; Cook, V; Cotton, R; Cowan, R F; Coyne, D G; Crawford, G; de Oliveira, A; Damerell, C J S; Daoudi, M; Dasu, S; De Groot, N; De Sangro, R; De Simone, P; De Simone, S; Dervan, P J; Dima, M; Dong, D N; Doser, Michael; Du, P Y C; Dubois, R; Duboscq, J E; Eisenstein, B I; Elia, R; Erdos, E; Erofeeva, I; Eschenburg, V; Etzion, E; Fahey, S; Falciai, D; Fan, C; Fernández, J P; Fero, M J; Flood, K; Frey, R; Friedman, Jerome Isaac; Furuno, K; Garwin, E L; Gillman, T; Gladding, G; Hallewell, G D; Hart, E L; Hasegawa, Y; Hasuko, K; Hedges, S; Hertzbach, S S; Hildreth, M D; Hitlin, D G; Honma, A; Huber, J S; Huffer, M E; Hughes, E W; Huynh, X; Hwang, H; Iwasaki, M; Iwasaki, Y; Izen, J M; Jackson, D J; Jacques, P; Jaros, J A; Jiang, Z Y; Johnson, A S; Johnson, J R; Johnson, R A; Junk, T R; Kajikawa, R; Kalelkar, M; Kamyshkov, Yu A; Kang, H J; Karliner, I; Kawahara, H; Kelsey, M H; Kendall, H W; Kim, Y D; King, M; King, R; Kofler, R R; Krishna, N M; Kwon, Y; Labs, J F; Kroeger, R S; Langston, M; Lath, A; Lauber, J A; Leith, D W G S; Lia, V; Lin, C; Liu, M X; Loreti, M; Lu, A; Lynch, H L; Ma, J; Mancinelli, G; Manly, S; Mantovani, G C; Markiewicz, T W; Maruyama, T; Masuda, H; Mazzucato, E; McGowan, J F; McKemey, A K; Meadows, B T; Messner, R; Mockett, P M; Moffeit, K C; Moore, T B; Morii, M; Mours, B; Müller, D; Müller, G; Murzin, V; Nagamine, T; Narita, S; Nauenberg, U; Neal, H; Nesom, G; Nussbaum, M; Ohnishi, Y; Oishi, N; Onoprienko, D; Osborne, L S; Panvini, R S; Park, C H; Park, H; Pavel, T J; Peruzzi, I; Pescara, L; Piccolo, M; Piemontese, L; Pieroni, E; Pitts, K T; Plano, R J; Prepost, R; Prescott, C Y; Punkar, G; Quigley, J; Ratcliff, B N; Reeves, K; Reeves, T W; Reidy, J; Reinertsen, P L; Rensing, P E; Rochester, L S; Rowson, P C; Russell, J J; Saxton, O H; Schalk, T; Schindler, R H; Schneekloth, U; Schumm, B A; Schwiening, J; Seiden, A; Sen, S; Serbo, V V; Shaevitz, M H; Shank, J T; Shapiro, G; Sherden, D J; Shmakov, K D; Simopoulos, C; Sinev, N B; Smith, S R; Smy, M B; Snyder, J A; Sokoloff, M D; Stängle, H; Stahl, A; Stamer, P; Steiner, H; Steiner, R; Strauss, M G; Su, D; Suekane, F; Sugiyama, A; Suzuki, A; Suzuki, S; Swartz, M; Szumilo, A; Takahashi, T; Taylor, F E; Thaler, J J; Thom, J; Torrence, E; Trandafir, A I; Turk, J D; Usher, T; Vavra, J; Vella, E; Venuti, J P; Verdier, R; Wagner, S R; Waite, A P; Walston, S; Wang, J; Watts, S J; Weidemann, A W; Weiss, E R; Whitaker, J S; White, S L; Wickens, F J; Williams, D A; Williams, D C; Williams, S H; Willocq, S; Wilson, R J; Wisniewski, W J; Wittlin, J L; Woods, M; Word, G B; Wright, T R; Wyss, J; Yamamoto, R K; Yang, X Q; Yashima, J; Yellin, S J; Young, C C; Yuta, H; Zapalac, G; Zdarko, R W; Zeitlin, C; Zhou, J

    2006-01-01

    We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLD experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, $MZ$ and $GZ$, and its couplings to fermions, for example the $ ho$ parameter and the effective electroweak mixing angle for leptons, are precisely measured: egin{eqnarray*} MZ & = & 91.1875 pm 0.0021~GeV \\ GZ & = & 2.4952 pm 0.0023~GeV \\ ho_ell & = & 1.0050 pm 0.0010 \\ swsqeffl & =& 0.23153 pm 0.00016 ,. end{eqnarray*} The number of light neutrino species is determined to be $2.9840pm0.0082$, in agreement with the three observed generations of fundamental fermions. The results are compared to the pr...

  9. Measurements of the anomalous RF surface resistance of niobium using a dielectric resonator

    International Nuclear Information System (INIS)

    Moffat, D.; Bolore, M.; Bonin, B.; Jacques, E.; Safa, H.

    1996-01-01

    The surface resistance of high and low RRR niobium plates at 4.2 K and 1.8 K has been measured as a function of many processing and testing parameters. A dielectric resonator was used instead of a resonant cavity. This resonator offered the ability to make many, sensitive measurements with an efficient use of time and helium. It was found that the surface resistance, R s , of RRR=190 niobium increased noticeably from the theoretical value if the cooling rate was slower than∼10 K/min. Fast-cooled plates subsequently warmed to 130 K, and the recooled, showed a larger increase in R s than plates warmed to either 100 K or 160 K. Both chemically polished, and electropolished RRR=190 plates showed the effects of the 'Q-virus'. A heat treatment of 200 deg C made the RRR=190 plates less susceptible to the 'Q-virus'. RRR=30 niobium plates did not show any increase in R s , regardless of treatment. (author)

  10. CMOS compatible fabrication process of MEMS resonator for timing reference and sensing application

    Science.gov (United States)

    Huynh, Duc H.; Nguyen, Phuong D.; Nguyen, Thanh C.; Skafidas, Stan; Evans, Robin

    2015-12-01

    Frequency reference and timing control devices are ubiquitous in electronic applications. There is at least one resonator required for each of this device. Currently electromechanical resonators such as crystal resonator, ceramic resonator are the ultimate choices. This tendency will probably keep going for many more years. However, current market demands for small size, low power consumption, cheap and reliable products, has divulged many limitations of this type of resonators. They cannot be integrated into standard CMOS (Complement metaloxide- semiconductor) IC (Integrated Circuit) due to material and fabrication process incompatibility. Currently, these devices are off-chip and they require external circuitries to interface with the ICs. This configuration significantly increases the overall size and cost of the entire electronic system. In addition, extra external connection, especially at high frequency, will potentially create negative impacts on the performance of the entire system due to signal degradation and parasitic effects. Furthermore, due to off-chip packaging nature, these devices are quite expensive, particularly for high frequency and high quality factor devices. To address these issues, researchers have been intensively studying on an alternative for type of resonator by utilizing the new emerging MEMS (Micro-electro-mechanical systems) technology. Recent progress in this field has demonstrated a MEMS resonator with resonant frequency of 2.97 GHz and quality factor (measured in vacuum) of 42900. Despite this great achievement, this prototype is still far from being fully integrated into CMOS system due to incompatibility in fabrication process and its high series motional impedance. On the other hand, fully integrated MEMS resonator had been demonstrated but at lower frequency and quality factor. We propose a design and fabrication process for a low cost, high frequency and a high quality MEMS resonator, which can be integrated into a standard

  11. Measurement of resonance absorption integrals; Mesure des integrales de resonance d'absorption

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The measurements are carried out by the pile oscillator technique, without cadmium filter., in a spectrum rich in epithermal neutrons. The values are extrapolated to infinite dilution and corrected for the junction function. For the excess on the part in l/V, the following values are found: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (author) [French] Les mesures sont effectuees par la methode d'oscillation, sans filtre de cadmium, dans un spectre riche en neutrons epithermiques. Les valeurs sont extrapolees a la dilution infinie et corrigees de la fonction de jonction. On trouve, pour l'exces sur la partie en l/v: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (auteur)

  12. Series elasticity of the human triceps surae muscle : Measurement by controlled-release vs. resonance methods.

    NARCIS (Netherlands)

    Hof, AL; Boom, H; Robinson, C; Rutten, W; Neuman, M; Wijkstra, H

    1997-01-01

    With a newly developed Controlled-Release Ergometer the complete characteristic of the series elastic component can be measured in human muscles. Previous estimates were based on the resonance method: muscle elasticity was assessed from the resonance frequency of the muscle elasticity connected to a

  13. Using Micromechanical Resonators to Measure Rheological Properties and Alcohol Content of Model Solutions and Commercial Beverages

    Directory of Open Access Journals (Sweden)

    Bart W. Hoogenboom

    2012-05-01

    Full Text Available Micromechanic resonators provide a small-volume and potentially high-throughput method to determine rheological properties of fluids. Here we explore the accuracy in measuring mass density and viscosity of ethanol-water and glycerol-water model solutions, using a simple and easily implemented model to deduce the hydrodynamic effects on resonating cantilevers of various length-to-width aspect ratios. We next show that these measurements can be extended to determine the alcohol percentage of both model solutions and commercial beverages such as beer, wine and liquor. This demonstrates how micromechanical resonators can be used for quality control of every-day drinks.

  14. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  15. Study of 234U(n,f) Resonances Measured at the CERN n_TOF Facility

    CERN Document Server

    Leal-Cidoncha, E; Paradela, C; Tarrío, D; Leong, L S; Audouin, L; Tassan-Got, L; Praena, J; Berthier, B; Ferrant, L; Isaev, S; Le Naour, C; Stephan, C; Trubert, D; Abbondanno, U; Aerts, G; Álvarez, H; Álvarez-Velarde, F; Andriamonje, S; Andrzejewski, J; Badurek, G; Baumann, P; Bečvář, F; Berthoumieux, E; Calviño, F; Calviani, M; Cano-Ott, D; Capote, R; Carrapiço, C; Cennini, P.; Chepel, V; Chiaveri, E.; Colonna, N; Cortes, G; Couture, A; Cox, J; Dahlfors, M; David, S.; Dillmann, I; Domingo-Pardo, C; Dridi, W; Eleftheriadis, C; Embid-Segura, M; Ferrari, A.; Ferreira-Marques, R; Fujii, K; Furman, W; Gonçalves, I; González-Romero, E; Gramegna, F; Guerrero, C; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martinez, A.; Igashira, M; Jericha, E; Kadi, Y.; Käppeler, F; Karadimos, D; Kerveno, M; Koehler, P; Kossionides, E; Krtička, M; Lampoudis, C; Leeb, H; Lindote, A; Lopes, I; Lozano, M; Lukic, S; Marganiec, J; Marrone, S; Martínez, T; Massimi, C; Mastinu, P; Mengoni, A; Milazzo, P M; Moreau, C; Mosconi, M; Neves, F; Oberhummer, H; O'Brien, S; Oshima, M; Pancin, J; Papadopoulos, C; Pavlik, A; Pavlopoulos, P.; Perrot, L; Pigni, M T; Plag, R; Plompen, A; Plukis, A; Poch, A; Pretel, C; Quesada, J; Rauscher, T.; Reifarth, R; Rubbia, C.; Rudolf, G; Rullhusen, P; Salgado, J; Santos, C; Sarchiapone, L.; Savvidis, I; Tagliente, G; Tain, J L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A.; Villamarin, D; Vincente, M C; Vlachoudis, V.; Vlastou, R; Voss, F; Walter, S; Wiescher, M; Wisshak, K

    2014-01-01

    We present the analysis of the resolved resonance region for the U-234(n,f) cross section data measured at the CERN n\\_TOF facility. The resonance parameters in the energy range from 1 eV to 1500 eV have been obtained with the SAMMY code by using as initial parameters for the fit the resonance parameters of the JENDL-3.3 evaluation. In addition, the statistical analysis has been accomplished, partly with the SAMDIST code, in order to study the level spacing and the Mehta-Dyson correlation.

  16. Measurement of resonance modes causative of beam position monitor signal noise in vacuum chamber of storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Youngdo; Hwang, Ilmoon; Park, Sungju [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Kim, Changbum, E-mail: chbkim@postech.ac.k [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2011-05-11

    It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S{sub 21}) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.

  17. Measurement of resonance modes causative of beam position monitor signal noise in vacuum chamber of storage ring

    International Nuclear Information System (INIS)

    Joo, Youngdo; Hwang, Ilmoon; Park, Sungju; Kim, Changbum

    2011-01-01

    It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S 21 ) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.

  18. Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

    Directory of Open Access Journals (Sweden)

    Sascha Geidel

    2016-09-01

    Full Text Available While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

  19. Conformally integrated stent cell resonators for wireless monitoring of peripheral artery disease

    KAUST Repository

    Viswanath, Anupam

    2013-01-01

    This paper presents the design and in vitro evaluation of magnetoelastic sensors intended for wireless monitoring of tissue accumulation in peripheral artery stents. The sensors, shaped like stent cells, are fabricated from 28-μm thick foils of magnetoelastic Ni-Fe alloy and are conformally integrated with the stent. The typical sensitivity to viscosity is 427 ppm/cP over a 1.1-8.6 cP range. The sensitivity to mass loading is typically 63,000-65000 ppm/mg with resonant frequency showing an 8.1% reduction for an applied mass that is 15% of the unloaded mass of the sensor. © 2013 IEEE.

  20. Electroweak coupling measurements from polarized Bhabha scattering at the Z{sup 0} resonance

    Energy Technology Data Exchange (ETDEWEB)

    Pitts, K.T.

    1994-03-01

    The cross section for Bhabha scattering (e{sup +}e{sup {minus}} {yields} e{sup +}e{sup {minus}}) with polarized electrons at the center of mass energy of the Z{sup 0} resonance has been measured with the SLD experiment at the Stanford Linear Accelerator Center during the 1992 and 1993 runs. The electroweak couplings of the electron are extracted. At small angles the measurement is done in the SLD Silicon/Tungsten Luminosity Monitor (LMSAT). A detailed description of the design, construction, commissioning and operation of the LMSAT is provided. The integrated luminosity for 1992 is measured to be L = 420.86{plus_minus}2.56 (stat){plus_minus}4.23 (sys) nb{sup {minus}1}. The luminosity asymmetry for polarized beams is measured to be A{sub LR}(LUM) = (1.7 {plus_minus} 6.4) {times} 10{sup {minus}3}. The large angle polarized Bhabha scattering reveals the effective electron vector and axial vector couplings to the Z{sup 0} through the measurement of the Z{sup 0} {yields} e{sup +}e{sup {minus}} partial width, {Gamma}{sub ee}, and the parity violation parameter, A{sub e}. From the combined 1992 and 1993 data the effective electron vector and axial vector couplings are measured to be {bar g}{sub v}{sup e} = {minus}0.0495{plus_minus}0.0096{plus_minus}0.0030, and {bar g}{sub {alpha}}{sup e} = {minus}0.4977{plus_minus}0.0035{plus_minus}0.0064 respectively. The effective weak mixing angle is measured to be sin{sup 2}{theta}{sub W}{sup eff} = 0.2251{plus_minus}0.0049{plus_minus}0.0015. These results are compared with other experiments.

  1. Advanced photonic filters based on cascaded Sagnac loop reflector resonators in silicon-on-insulator nanowires

    Science.gov (United States)

    Wu, Jiayang; Moein, Tania; Xu, Xingyuan; Moss, David J.

    2018-04-01

    We demonstrate advanced integrated photonic filters in silicon-on-insulator (SOI) nanowires implemented by cascaded Sagnac loop reflector (CSLR) resonators. We investigate mode splitting in these standing-wave (SW) resonators and demonstrate its use for engineering the spectral profile of on-chip photonic filters. By changing the reflectivity of the Sagnac loop reflectors (SLRs) and the phase shifts along the connecting waveguides, we tailor mode splitting in the CSLR resonators to achieve a wide range of filter shapes for diverse applications including enhanced light trapping, flat-top filtering, Q factor enhancement, and signal reshaping. We present the theoretical designs and compare the CSLR resonators with three, four, and eight SLRs fabricated in SOI. We achieve versatile filter shapes in the measured transmission spectra via diverse mode splitting that agree well with theory. This work confirms the effectiveness of using CSLR resonators as integrated multi-functional SW filters for flexible spectral engineering.

  2. In vivo measurement of phosphorus energy metabolites by topical magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Watari, Hiroshi [National Institute for Physiological Sciences, Okazaki Aichi (Japan); Koizuka, Izumi; Takada, Muneharu; Naruse, Shoji

    1982-12-01

    An apparatus of TMR (topical magnetic resonance) was briefly described, and the technique to use it was shown. The effect of digital filter was demonstrated and measurement of a pulse width was shown using a phantom. Pulse width and /sup 31/P-NMR spectrum measured in a rat head were shown. The /sup 31/P-NMR spectrum well revealed the phosphorus energy metabolites such as creatine phosphoric acid, ATP, and ADP.

  3. Possibility and necessity measures and integral equivalence

    Czech Academy of Sciences Publication Activity Database

    Chen, T.; Mesiar, Radko; Li, J.; Stupňanová, A.

    2017-01-01

    Roč. 86, č. 1 (2017), s. 62-72 ISSN 0888-613X Institutional support: RVO:67985556 Keywords : Integral equivalence * Necessity measure * Possibility measure * Survival function * Universal integral Subject RIV: BA - General Mathematics OBOR OECD: Statistics and probability Impact factor: 2.845, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477092.pdf

  4. Coherent versus incoherent resonant emission: an experimental method for easy discrimination and measurement

    Science.gov (United States)

    Ceccherini, S.; Colocci, M.; Gurioli, M.; Bogani, F.

    1998-11-01

    The distinction between the coherent and the incoherent component of the radiation emitted from resonantly excited material systems is difficult experimentally, particularly when ultra-short optical pulses are used for excitation. We propose an experimental procedure allowing an easy measurement of the two components. The method is completely general and applicable to any kind of physical system; its feasibility is demonstrated on the resonant emission from excitons in a semiconductor quantum well.

  5. Comparative analysis of nuclear magnetic resonance well logging and nuclear magnetic resonance mud logging

    International Nuclear Information System (INIS)

    Yuan Zugui

    2008-01-01

    The hydrogen atoms in oil and water are able to resonate and generate signals in the magnetic field, which is used by the NMR (nuclear magnetic resonance) technology in petroleum engineering to research and evaluate rock characteristics. NMR well logging was used to measure the physical property parameters of the strata in well bore, whereas NMR mud logging was used to analyze (while drilling) the physical property parameters of cores, cuttings and sidewall coring samples on surface (drilling site). Based on the comparative analysis of the porosity and permeability parameters obtained by NMR well logging and those from analysis of the cores, cuttings and sidewall coring samples by NMR mud logging in the same depth of 13 wells, these two methods are of certain difference, but their integral tendency is relatively good. (authors)

  6. Surface magnetic anisotropy in glass-coated amorphous microwires as determined from ferromagnetic resonance measurements

    International Nuclear Information System (INIS)

    Garcia-Miquel, H.; Garcia, J.M.; Garcia-Beneytez, J.M.; Vazquez, M.

    2001-01-01

    The ferromagnetic resonance frequency of different Co base glass-coated amorphous magnetic microwires about 3.5 μm in diameter with negative, vanishing and positive magnetostriction has been investigated from power absorption measurements in the microwave frequency range. The experimental technique employed here involves the replacement of the dielectric of a coaxial transmission line by the sample to be measured. From the evolution of the resonance frequency with DC applied magnetic field, the surface magnetic anisotropy field of the microwires has been quantitatively obtained and, as expected, found to depend on the sign and strength of the magnetostriction. Similar values for the surface anisotropy are obtained in comparison with bulk anisotropy as determined from quasi-static hysteresis loops measurements

  7. Determination of the quasi-TE mode (in-plane) graphene linear absorption coefficient via integration with silicon-on-insulator racetrack cavity resonators.

    Science.gov (United States)

    Crowe, Iain F; Clark, Nicholas; Hussein, Siham; Towlson, Brian; Whittaker, Eric; Milosevic, Milan M; Gardes, Frederic Y; Mashanovich, Goran Z; Halsall, Matthew P; Vijayaraghaven, Aravind

    2014-07-28

    We examine the near-IR light-matter interaction for graphene integrated cavity ring resonators based on silicon-on-insulator (SOI) race-track waveguides. Fitting of the cavity resonances from quasi-TE mode transmission spectra reveal the real part of the effective refractive index for graphene, n(eff) = 2.23 ± 0.02 and linear absorption coefficient, α(gTE) = 0.11 ± 0.01dBμm(-1). The evanescent nature of the guided mode coupling to graphene at resonance depends strongly on the height of the graphene above the cavity, which places limits on the cavity length for optical sensing applications.

  8. High Resolution and Large Dynamic Range Resonant Pressure Sensor Based on Q-Factor Measurement

    Science.gov (United States)

    Gutierrez, Roman C. (Inventor); Stell, Christopher B. (Inventor); Tang, Tony K. (Inventor); Vorperian, Vatche (Inventor); Wilcox, Jaroslava (Inventor); Shcheglov, Kirill (Inventor); Kaiser, William J. (Inventor)

    2000-01-01

    A pressure sensor has a high degree of accuracy over a wide range of pressures. Using a pressure sensor relying upon resonant oscillations to determine pressure, a driving circuit drives such a pressure sensor at resonance and tracks resonant frequency and amplitude shifts with changes in pressure. Pressure changes affect the Q-factor of the resonating portion of the pressure sensor. Such Q-factor changes are detected by the driving/sensing circuit which in turn tracks the changes in resonant frequency to maintain the pressure sensor at resonance. Changes in the Q-factor are reflected in changes of amplitude of the resonating pressure sensor. In response, upon sensing the changes in the amplitude, the driving circuit changes the force or strength of the electrostatic driving signal to maintain the resonator at constant amplitude. The amplitude of the driving signals become a direct measure of the changes in pressure as the operating characteristics of the resonator give rise to a linear response curve for the amplitude of the driving signal. Pressure change resolution is on the order of 10(exp -6) torr over a range spanning from 7,600 torr to 10(exp -6) torr. No temperature compensation for the pressure sensor of the present invention is foreseen. Power requirements for the pressure sensor are generally minimal due to the low-loss mechanical design of the resonating pressure sensor and the simple control electronics.

  9. Measurement of isovector giant quadrupole resonance in 40Ca

    International Nuclear Information System (INIS)

    Sims, D.A.; Thompson, M.N.; Rassool, R.; Adler, J.O.; Andersson, B.E.; Hansen, K.; Issaksson, L.; Nilsson, B.; Ruijter, H.; Schroeder, B.; Annand, J.R.M.; McGeorge, J.C.; Crawford, G.I.; Miller, G.J.

    1997-01-01

    The 40 Ca(γ,n) reaction was measured using tagged photons in the energy range 25-50 MeV. Neutrons were detected using two 9-element, liquid scintillator, neutron detectors placed at angles of 55 deg and 125 deg at flight path of 3.2 m. The absolute cross section was determined relative to that for D (γ,n)p, which was measured using a heavy water target. The forward/backward asymmetry in the 40 Ca (γ, n) cross section, resulting from E1/E2 interference has been used to locate and parametrize the isovector giant quadrupole resonance (IVQR). 6 refs., 2 figs

  10. Measurement of coherent π0 photoproduction on 3He and 3H in the resonance region

    International Nuclear Information System (INIS)

    Bellinghausen, B.; Gassen, H.J.; Reese, E.; Reichelt, T.; Stipp, P.

    1984-01-01

    Neutral pion photoproduction has been measured on 3 He and 3 H nuclei in the Δ(1,232) resonance region. Resonance averaged cross-sections are presented as a function of momentum transfer and compared to theoretical calculations. (orig.)

  11. Generalized measures and the Feynman path integral

    International Nuclear Information System (INIS)

    Maslov, V.P.; Chebotarev, A.M.

    1976-01-01

    Generalizations are obtained for the earlier results by the authors concerning the inclusion of the Feynmann path integral in the momentum representation into the general integration theory. Feynmann path integrals are considered which do not represent T-products. Generalized Feynmann measure in the configuration representation is introduced

  12. Bandwidth-limited control and ringdown suppression in high-Q resonators.

    Science.gov (United States)

    Borneman, Troy W; Cory, David G

    2012-12-01

    We describe how the transient behavior of a tuned and matched resonator circuit and a ringdown suppression pulse may be integrated into an optimal control theory (OCT) pulse-design algorithm to derive control sequences with limited ringdown that perform a desired quantum operation in the presence of resonator distortions of the ideal waveform. Inclusion of ringdown suppression in numerical pulse optimizations significantly reduces spectrometer deadtime when using high quality factor (high-Q) resonators, leading to increased signal-to-noise ratio (SNR) and sensitivity of inductive measurements. To demonstrate the method, we experimentally measure the free-induction decay of an inhomogeneously broadened solid-state free radical spin system at high Q. The measurement is enabled by using a numerically optimized bandwidth-limited OCT pulse, including ringdown suppression, robust to variations in static and microwave field strengths. We also discuss the applications of pulse design in high-Q resonators to universal control of anisotropic-hyperfine coupled electron-nuclear spin systems via electron-only modulation even when the bandwidth of the resonator is significantly smaller than the hyperfine coupling strength. These results demonstrate how limitations imposed by linear response theory may be vastly exceeded when using a sufficiently accurate system model to optimize pulses of high complexity. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. The Use of Helmholtz Resonance for Measuring the Volume of Liquids and Solids

    Directory of Open Access Journals (Sweden)

    Clive E. Davies

    2010-11-01

    Full Text Available An experimental investigation was undertaken to ascertain the potential of using Helmholtz resonance for volume determination and the factors that may influence accuracy. The uses for a rapid non-interference volume measurement system range from agricultural produce and mineral sampling through to liquid fill measurements. By weighing the sample the density can also measured indirectly.

  14. Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments

    International Nuclear Information System (INIS)

    MJ Trbovich; DP Barry; RE Slovacck; Y Danon; RC Block; JA Burke; NJ Drindak; G Leinweber; RV Ballad

    2004-01-01

    The focus of this work is to determine resonance parameters for stable hafnium isotopes in the 0.005-200 eV region, with special emphasis on the overlapping 176 Hf and 178 Hf resonances near 8 eV. The large neutron cross section of hafnium, combined with its corrosion resistance and excellent mechanical properties, make it a useful material for controlling nuclear reactions. Experiments measuring neutron capture and transmission were performed at the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) using the time of flight method. 6 Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m. Capture experiments were done using a sixteen section NaI(Tl) multiplicity detector at a flight path length of 25 m. These experiments utilized various thicknesses of metallic and isotopically-enriched liquid samples. The liquid samples were designed to provide information on the 176 Hf and 178 Hf contributions to the 8 eV doublet without saturation. Data analysis was done using the R-matrix Bayesian code SAMMY version M6 beta. SAMMY is able to account for experimental resolution effects for each of the experimental setups at the RPI LINAC, and also can correct for multiple scattering effects in neutron capture yield data. The combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005-200 eV. Resonance integrals were calculated along with errors for each hafnium isotope using the NJOY [1] and INTER [2] codes. The isotopic resonance integrals calculated were significantly different than previously published values; however the calculated elemental hafnium resonance integral changed very little

  15. Resonance shielding in thermal reactor lattices

    International Nuclear Information System (INIS)

    Rothenstein, W.; Taviv, E.; Aminpour, M.

    1982-01-01

    The theoretical foundations of a new methodology for the accurate treatment of resonance absorption in thermal reactor lattice analysis are presented. This methodology is based on the solution of the point-energy transport equation in its integral or integro-differential form for a heterogeneous lattice using detailed resonance cross-section profiles. The methodology is applied to LWR benchmark analysis, with emphasis on temperature dependence of resonance absorption during fuel depletion, spatial and mutual self-shielding, integral parameter analysis and treatment of cluster geometry. The capabilities of the OZMA code, which implements the new methodology are discussed. These capabilities provide a means against which simpler and more rapid resonance absorption algorithms can be checked. (author)

  16. Measurement of electron paramagnetic resonance using terahertz time-domain spectroscopy.

    Science.gov (United States)

    Kozuki, Kohei; Nagashima, Takeshi; Hangyo, Masanori

    2011-12-05

    We present a frequency-domain electron spin resonance (ESR) measurement system using terahertz time-domain spectroscopy. A crossed polarizer technique is utilized to increase the sensitivity in detecting weak ESR signals of paramagnets caused by magnetic dipole transitions between magnetic sublevels. We demonstrate the measurements of ESR signal of paramagnetic copper(II) sulfate pentahydrate with uniaxial anisotropy of the g-factor under magnetic fields up to 10 T. The lineshape of the obtained ESR signals agrees well with the theoretical predictions for a powder sample with the uniaxial anisotropy.

  17. Regenerative feedback resonant circuit

    Science.gov (United States)

    Jones, A. Mark; Kelly, James F.; McCloy, John S.; McMakin, Douglas L.

    2014-09-02

    A regenerative feedback resonant circuit for measuring a transient response in a loop is disclosed. The circuit includes an amplifier for generating a signal in the loop. The circuit further includes a resonator having a resonant cavity and a material located within the cavity. The signal sent into the resonator produces a resonant frequency. A variation of the resonant frequency due to perturbations in electromagnetic properties of the material is measured.

  18. The Fourier transform method for infinite medium resonance absorption problems

    International Nuclear Information System (INIS)

    Menon, S.V.G.; Sahni, D.C.

    1978-01-01

    A new method, using Fourier transforms, is developed for solving the integral equation of slowing down of neutrons in the resonance region. The transformations replace the slowing down equation with a discontinuous kernel by an integral equation with a continuous kernel over the interval (-infinity, infinity). Further the Doppler broadened line shape functions have simple analytical representations in the transform variable. In the limit of zero temperature, the integral equation reduces to a second order differential equation. Accurate expressions for the zero temperature resonance integrals are derived, using the WKB method. In general, the integral equation is seen to be amenable to solution by Ganss-Hermite quadrature formule. Doppler coefficients of 238 U resonances are given and compared with Monte Carlo calculations. The method is extended to include the effect of interference between neighbouring resonances of an absorber. For the case of two interfering resonances the slowing down equation is transformed to the coupled integral equations that are amenable to solution by methods indicated earlier. Numerical results presented for the low lying thorium-232 doublet show that the Doppler coefficients of the resonances are reduced considerably because of the overlap between them. (author)

  19. Precision polarization measurements of atoms in a far-off-resonance optical dipole trap

    International Nuclear Information System (INIS)

    Fang, F.; Vieira, D. J.; Zhao, X.

    2011-01-01

    Precision measurement of atomic and nuclear polarization is an essential step for beta-asymmetry measurement of radioactive atoms. In this paper, we report the polarization measurement of Rb atoms in an yttrium-aluminum-garnet (YAG) far-off-resonance optical dipole trap. We have prepared a cold cloud of polarized Rb atoms in the YAG dipole trap by optical pumping and achieved an initial nuclear polarization of up to 97.2(5)%. The initial atom distribution in different Zeeman levels is measured by using a combination of microwave excitation, laser pushing, and atomic retrap techniques. The nuclear-spin polarization is further purified to 99.2(2)% in 10 s and maintained above 99% because the two-body collision loss rate between atoms in mixed spin states is greater than the one-body trap loss rate. Systematic effects on the nuclear polarization, including the off-resonance Raman scattering, magnetic field gradient, and background gas collisions, are discussed.

  20. Thermal neutron capture cross sections resonance integrals and g-factors

    International Nuclear Information System (INIS)

    Mughabghab, S.F.

    2003-02-01

    The thermal radiative capture cross sections and resonance integrals of elements and isotopes with atomic numbers from 1 to 83 (as well as 232 Th and 238 U) have been re-evaluated by taking into consideration all known pertinent data published since 1979. This work has been undertaken as part of an IAEA co-ordinated research project on 'Prompt capture gamma-ray activation analysis'. Westcott g-factors for radiative capture cross sections at a temperature of 300K were computed by utilizing the INTER code and ENDF-B/VI (Release 8) library files. The temperature dependence of the Westcott g-factor is illustrated for 113 Cd, 124 Xe and 157 Gd at temperatures of 150, 294 and 400K. Comparisons have also been made of the newly evaluated capture cross sections of 6 Li, 7 Li, 12 C and 207 Pb with those determined by the k 0 method. (author)

  1. 3C-SiC microdisk mechanical resonators with multimode resonances at radio frequencies

    Science.gov (United States)

    Lee, Jaesung; Zamani, Hamidrera; Rajgopal, Srihari; Zorman, Christian A.; X-L Feng, Philip

    2017-07-01

    We report on the design, modeling, fabrication and measurement of single-crystal 3C-silicon carbide (SiC) microdisk mechanical resonators with multimode resonances operating at radio frequencies (RF). These microdisk resonators (center-clamped on a vertical stem pedestal) offer multiple flexural-mode resonances with frequencies dependent on both disk and anchor dimensions. The resonators are made using a novel fabrication method comprised of focused ion beam nanomachining and hydroflouic : nitric : acetic (HNA) acid etching. Resonance peaks (in the frequency spectrum) are detected through laser-interferometry measurements. Resonators with different dimensions are tested, and multimode resonances, mode splitting, energy dissipation (in the form of quality factor measurement) are investigated. Further, we demonstrate a feedback oscillator based on a passive 3C-SiC resonator. This investigation provides important guidelines for microdisk resonator development, ranging from an analytical prediction of frequency scaling law to fabrication, suggesting RF microdisk resonators can be good candidates for future sensing applications in harsh environments.

  2. Advanced photonic filters based on cascaded Sagnac loop reflector resonators in silicon-on-insulator nanowires

    Directory of Open Access Journals (Sweden)

    Jiayang Wu

    2018-04-01

    Full Text Available We demonstrate advanced integrated photonic filters in silicon-on-insulator (SOI nanowires implemented by cascaded Sagnac loop reflector (CSLR resonators. We investigate mode splitting in these standing-wave (SW resonators and demonstrate its use for engineering the spectral profile of on-chip photonic filters. By changing the reflectivity of the Sagnac loop reflectors (SLRs and the phase shifts along the connecting waveguides, we tailor mode splitting in the CSLR resonators to achieve a wide range of filter shapes for diverse applications including enhanced light trapping, flat-top filtering, Q factor enhancement, and signal reshaping. We present the theoretical designs and compare the CSLR resonators with three, four, and eight SLRs fabricated in SOI. We achieve versatile filter shapes in the measured transmission spectra via diverse mode splitting that agree well with theory. This work confirms the effectiveness of using CSLR resonators as integrated multi-functional SW filters for flexible spectral engineering.

  3. Hollow Microtube Resonators via Silicon Self-Assembly toward Subattogram Mass Sensing Applications.

    Science.gov (United States)

    Kim, Joohyun; Song, Jungki; Kim, Kwangseok; Kim, Seokbeom; Song, Jihwan; Kim, Namsu; Khan, M Faheem; Zhang, Linan; Sader, John E; Park, Keunhan; Kim, Dongchoul; Thundat, Thomas; Lee, Jungchul

    2016-03-09

    Fluidic resonators with integrated microchannels (hollow resonators) are attractive for mass, density, and volume measurements of single micro/nanoparticles and cells, yet their widespread use is limited by the complexity of their fabrication. Here we report a simple and cost-effective approach for fabricating hollow microtube resonators. A prestructured silicon wafer is annealed at high temperature under a controlled atmosphere to form self-assembled buried cavities. The interiors of these cavities are oxidized to produce thin oxide tubes, following which the surrounding silicon material is selectively etched away to suspend the oxide tubes. This simple three-step process easily produces hollow microtube resonators. We report another innovation in the capping glass wafer where we integrate fluidic access channels and getter materials along with residual gas suction channels. Combined together, only five photolithographic steps and one bonding step are required to fabricate vacuum-packaged hollow microtube resonators that exhibit quality factors as high as ∼ 13,000. We take one step further to explore additionally attractive features including the ability to tune the device responsivity, changing the resonator material, and scaling down the resonator size. The resonator wall thickness of ∼ 120 nm and the channel hydraulic diameter of ∼ 60 nm are demonstrated solely by conventional microfabrication approaches. The unique characteristics of this new fabrication process facilitate the widespread use of hollow microtube resonators, their translation between diverse research fields, and the production of commercially viable devices.

  4. Complex permittivity measurements of ferroelectric employing composite dielectric resonator technique

    Czech Academy of Sciences Publication Activity Database

    Krupka, J.; Zychowicz, T.; Bovtun, Viktor; Veljko, Sergiy

    2006-01-01

    Roč. 53, č. 10 (2006), s. 1883-1888 ISSN 0885-3010 R&D Projects: GA AV ČR(CZ) IAA1010213; GA ČR(CZ) GA202/04/0993; GA ČR(CZ) GA202/06/0403 Institutional research plan: CEZ:AV0Z10100520 Keywords : dielectric resonator * ferroelectrics * microwave measurements Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.729, year: 2006

  5. Application of nuclear resonance scattering for in vivo measurements

    International Nuclear Information System (INIS)

    Wielopolski, L.; Vartsky, D.; Cohn, S.H.

    1983-01-01

    Nuclear resonance scattering is applied in our laboratory to measure hepatic and cardiac iron overload. For iron analysis, a gaseous source of 4 mg MnCl 2 is introduced into an evacuated quartz vial. Following irradiation in a nuclear reactor, 56 Mn decays by beta emission to the 847-keV level of 56 Fe, which subsequently decays to the ground state of 56 Fe with a 7 ps half-life. The principal aim of this work is to evaluate the efficacy of the iron chelation therapy. Serial measurements over a time period of 6 to 12 months of a given patient will enable us to see how the iron is removed from the critical organs

  6. Spin-flip measurements in the proton inelastic scattering on 12C and giant resonance effects

    International Nuclear Information System (INIS)

    De Leo, R.; D'Erasmo, G.; Ferrero, F.; Pantaleo, A.; Pignanelli, M.

    1975-01-01

    Differential cross sections and spin-flip probabilities (SFP) for the inelastic scattering of protons, exciting the 2 + state at 4.43 MeV in 12 C, have been measured at several incident energies between 15.9 and 37.6 MeV. The changes in the shape of the SFP angular distributions are rather limited, while the absolute values show a pronounced increase, resonant like, in two energy regions centered at about 20 and 29 MeV. The second resonance reproduces very closely the energy dependence of the E2 giant quadrupole strength found in a previous experiment. The resonance at 20 MeV should correspond to a substructure of the E1 giant dipole resonance. (Auth.)

  7. Geochemical Controls on Nuclear Magnetic Resonance Measurements

    International Nuclear Information System (INIS)

    Knight, Rosemary; Prasad, Manika; Keating, Kristina

    2003-01-01

    OAK-B135 Our research objectives are to determine, through an extensive set of laboratory experiments, the effect of the specific mineralogic form of iron and the effect of the distribution of iron on proton nuclear magnetic resonance (NMR) relaxation mechanisms. In the first nine months of this project, we have refined the experimental procedures to be used in the acquisition of the laboratory NMR data; have ordered, and conducted preliminary measurements on, the sand samples to be used in the experimental work; and have revised and completed the theoretical model to use in this project. Over the next year, our focus will be on completing the first phase of the experimental work where the form and distribution of the iron in the sands in varied

  8. Application of the resonant 52(p,γ)53Mn reaction to the measurement of chromium depth distributions

    International Nuclear Information System (INIS)

    Switkowski, Z.E.; Petty, R.J.; Clark, G.J.

    1979-01-01

    A resonance in the 52 Cr(p,γ) 53 Mn reaction has been investigated as a probe for the quantitative determination of chromium depth distributions. The relevant nuclear parameters of this resonance were measured to be: resonance energy, Esub(p)1005.2 +- 0.2 keV, total width GAMMA < 100 eV, and resonance strength, (2J+1)GAMMAsub(p)GAMMAsub(γ)/GAMMA = 0.89 +-0.11 eV. As an example of the use of the nuclear resonance technique, the chromium profile of an electroplated chrome black solar absorber surface has been studied and the results are presented

  9. Contribution to analytical theory of neutron resonance absorption in heterogeneous reactor systems with cylindrical geometry

    International Nuclear Information System (INIS)

    Slipicevic, K.

    1968-12-01

    Following a review of the existing theories od resonance absorption this thesis includes a new approach for calculating the effective resonance integral of absorbed neutrons, new approximate formula for the penetration factor, an analysis of the effective resonance integral and the correction of the resonance integral taking into account the interference of potential and resonance dissipation. A separate chapter is devoted to calculation of the effective resonance integral for the regular reactor lattice with cylindrical fuel elements

  10. On-resonance deformation effect measurements: A probe of order within chaos in the nucleus

    International Nuclear Information System (INIS)

    Davis, E.D.; Gould, C.R.; Gould, C.R.

    1998-01-01

    The statistics of on-resonance measurements of the deformation effect cross section σ 02 in unpolarized neutron transmission through an aligned 165 Ho target is discussed. Under the standard Porter-Thomas assumption about reduced partial width amplitudes, the sign of σ 02 is random at s-wave resonances with d-wave admixtures. Motivated by the observation of sign correlations in epithermal parity-violation studies, conditions under which a doorway state will give rise to σ 02 close-quote s of nonrandom sign are identified. Oblate shape isomers lying at excitation energies in the isolated resonance regime could meet these conditions. copyright 1998 The American Physical Society

  11. Heat dissipation due to ferromagnetic resonance in a ferromagnetic metal monitored by electrical resistance measurement

    International Nuclear Information System (INIS)

    Yamanoi, Kazuto; Yokotani, Yuki; Kimura, Takashi

    2015-01-01

    The heat dissipation due to the resonant precessional motion of the magnetization in a ferromagnetic metal has been investigated. We demonstrated that the temperature during the ferromagnetic resonance can be simply detected by the electrical resistance measurement of the Cu strip line in contact with the ferromagnetic metal. The temperature change of the Cu strip due to the ferromagnetic resonance was found to exceed 10 K, which significantly affects the spin-current transport. The influence of the thermal conductivity of the substrate on the heating was also investigated

  12. Optical resonator theory

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jaeg Won; Cho, Sunh Oh; Jeong, Young Uk; Lee, Byung Cheol; Lee, Jong Min

    2000-10-01

    In this report we present a theoretical study of bare optical resonators having in mind to extend it to active resonators. To compute diffractional losses, phase shifts, intensity distributions and phases of radiation fields on mirrors, we coded a package of numerical procedures on bases of a pair of integral equations. Two numerical schemes, a matrix formalism and an iterative method, are programmed for finding numeric solutions to the pair of integral equations. The iterative method had been tried by Fox and Li, but it was not applicable to cases for high Fresnel numbers since the numerical errors involved propagate and accumulate uncontrollably. In this report, we implemented the matrix method to extend the computational limit further. A great deal of case studies are carried out with various configurations of stable and unstable resonators. Our results presented in this report show not only a good agreement with the results previously obtained by Fox and Li, but also a legitimacy of our numerical procedures in high Fresnel numbers.

  13. Introduction to Measure Theory and Integration

    CERN Document Server

    Ambrosio, Luigi; Mennucci, Andrea

    2011-01-01

    This textbook collects the notes for an introductory course in measure theory and integration. The course was taught by the authors to undergraduate students of the Scuola Normale Superiore, in the years 2000-2011. The goal of the course was to present, in a quick but rigorous way, the modern point of view on measure theory and integration, putting Lebesgue's Euclidean space theory into a more general context and presenting the basic applications to Fourier series, calculus and real analysis. The text can also pave the way to more advanced courses in probability, stochastic processes or geomet

  14. Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling

    DEFF Research Database (Denmark)

    Miranda Gimenez-Ricco, Maria Jo; Olofsson, K; Sidaros, Karam

    2006-01-01

    Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term-born neon......Magnetic resonance arterial spin labeling (ASL) at 3 Tesla has been investigated as a quantitative technique for measuring regional cerebral perfusion (RCP) in newborn infants. RCP values were measured in 49 healthy neonates: 32 preterm infants born before 34 wk of gestation and 17 term...

  15. Joint quantum state tomography of an entangled qubit–resonator hybrid

    International Nuclear Information System (INIS)

    LinPeng, X Y; Zhang, H Z; Xu, K; Li, C Y; Zhong, Y P; Wang, Z L; Wang, H; Xie, Q W

    2013-01-01

    The integration of superconducting qubits and resonators in one circuit offers a promising solution for quantum information processing (QIP), which also realizes the on-chip analogue of cavity quantum electrodynamics (QED), known as circuit QED. In most prototype circuit designs, qubits are active processing elements and resonators are peripherals. As resonators typically have better coherence performance and more accessible energy levels, it is proposed that the entangled qubit–resonator hybrid can be used as a processing element. To achieve such a goal, an accurate measurement of the hybrid is first necessary. Here we demonstrate a joint quantum state tomography (QST) technique to fully characterize an entangled qubit–resonator hybrid. We benchmarked our QST technique by generating and accurately characterizing multiple states, e.g. |gN〉 + |e(N − 1)〉 where (|g〉 and |e〉) are the ground and excited states of the qubit and (|0〉,…,|N〉) are Fock states of the resonator. We further provided a numerical method to improve the QST efficiency and measured the decoherence dynamics of the bipartite hybrid, witnessing dissipation coming from both the qubit and the N-photon Fock state. As such, the joint QST presents an important step toward actively using the qubit–resonator element for QIP in hybrid quantum devices and for studying circuit QED. (paper)

  16. Resonant detectors and focal plane arrays for infrared detection

    Science.gov (United States)

    Choi, K. K.; Allen, S. C.; Sun, J. G.; DeCuir, E. A.

    2017-08-01

    We are developing resonator-QWIPs for narrowband and broadband long wavelength infrared detection. Detector pixels with 25 μm and 30 μm pitches were hybridized to fanout circuits and readout integrated electronics for radiometric measurements. With a low to moderate doping of 0.2-0.5 × 1018 cm-3 and a thin active layer thickness of 0.6-1.3 μm, we achieved a quantum efficiency between 25 and 37% and a conversion efficiency between of 15 and 20%. The temperature at which photocurrent equals dark current is about 65 K under F/2 optics for a cutoff wavelength up to 11 μm. The NEΔT of the FPAs is estimated to be 20 mK at 2 ms integration time and 60 K operating temperature. This good performance confirms the advantages of the resonator-QWIP approach.

  17. From VHF to UHF CMOS-MEMS Monolithically Integrated Resonators

    DEFF Research Database (Denmark)

    Teva, Jordi; Berini, Abadal Gabriel; Uranga, A.

    2008-01-01

    This paper presents the design, fabrication and characterization of microresonators exhibiting resonance frequencies in the VHF and UHF bands, fabricated using the available layers of the standard and commercial CMOS technology, AMS-0.35mum. The resonators are released in a post-CMOS process cons...

  18. A gateless charge integrator for Borexino energy measurement

    International Nuclear Information System (INIS)

    Lagomarsino, V.; Testera, G.

    1999-01-01

    A gateless charge integrator designed for the energy measurement in the Borexino experiment is described and the results of various tests performed on prototypes are shown. The circuit integrates always its input taking advantage of the AC coupling to the photomultipliers that equalizes to zero the charge associated with each event signal. A double sampling of the integrator output allows to perform a charge measurement in principle without dead time, avoiding the use of gate signals and baseline restoration networks and permitting a precise detection of the fast correlated events (delayed coincidences due to the decay of a nuclide producing a daughter having a lifetime in the tens of ns time range). The precision of the charge measurement is discussed together with the performances of the front end Borexino board where the integrator is mounted

  19. Improved method for measuring the electric fields in microwave cavity resonators

    International Nuclear Information System (INIS)

    Amato, J.C.; Herrmann, H.

    1985-01-01

    The electric field distribution in microwave cavities is commonly measured by frequency perturbation techniques. For many cavity modes which are important in accelerator applications, the standard bead-pulling technique cannot provide adequate discrimination between fields parallel and perpendicular to the particle trajectory, leading to inaccurate and ambiguous results. A method is described which substantially increases the directivity of the measurements. The method has been successfully used to determine the accelerator-related cavity parameters at frequencies up to three times the fundamental resonant frequency

  20. Observation of large scissors resonance strength in actinides.

    Science.gov (United States)

    Guttormsen, M; Bernstein, L A; Bürger, A; Görgen, A; Gunsing, F; Hagen, T W; Larsen, A C; Renstrøm, T; Siem, S; Wiedeking, M; Wilson, J N

    2012-10-19

    The orbital M1 scissors resonance has been measured for the first time in the quasicontinuum of actinides. Particle-γ coincidences are recorded with deuteron and (3)He-induced reactions on (232)Th. The residual nuclei (231,232,233)Th and (232,233) Pa show an unexpectedly strong integrated strength of B(M1)=11-15μ(n)(2) in the E(γ)=1.0-3.5 MeV region. The increased γ-decay probability in actinides due to scissors resonance is important for cross-section calculations for future fuel cycles of fast nuclear reactors and may also have an impact on stellar nucleosynthesis.

  1. Measuring cross-border regional STI integration

    Energy Technology Data Exchange (ETDEWEB)

    Makkonen, T

    2016-07-01

    Earlier quantitative studies on cross-border regional integration processes have commonly neglected science, technology and innovation (STI) indicators: even the most notable example of a composite indicator approach to measuring cross-border regional integration, i.e. the Oresund index, lacks a sub-category for STI. Consequently, by ignoring cross-border innovation and knowledge flows, the Oresund integration index fails to take into account one of the most important drivers of economic growth in cross-border regions. Therefore, a new composite STI indicator (sub-category) was introduced to strengthen the Oresund integration index. This was compiled from patent, publication and collaborative R&D project data. The findings show that this index performs reasonably well in depicting STI integration, while at the same time remaining simple and straightforward enough to be adopted in other crossborder regions. (Author)

  2. Functional magnetic resonance imaging of the truncus pulmonalis. Principles of magnetic resonance flux measurements for pulmonal hypertension diagnostics

    International Nuclear Information System (INIS)

    Abolmaali, N.

    2006-01-01

    This book gives a detailed introduction into the use of magnetic resonance flux measurements for the examination of pulmonal circulation. It presents the results of phantom experiments and evaluates and verifies sequence techniques optimised for the examination of the pulmonary circulation. This is followed by a description of an elegant experimental design for the quantification of pulmonal hypertension which is unique in its kind. The model can predict the consequences of acute, resistance-related pulmonal hypertension in a reproducible and reversible manner. It thus provides a means of evaluating pulmonal applications of magnetic resonance imaging. The idea for these studies and its implementation are an outstanding example of teamwork and interdisciplinary cooperation. Applying the results to the patient after the statistical analysis is only a small step. The book presents the results of extensive normal value studies which will make it possible to use the measurement technology in paediatric cardiology. Its range of application also includes congenital heart defects, especially ventricular septal defects and primary as well as secondary forms of pulmonal hypertension. It is not only suitable for primary diagnostics but also for post-treatment follow-up and assessment of patients' progress

  3. Measurement of Charged Pions from Neutrino-produced Nuclear Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Clifford N. [Univ. of California, Irvine, CA (United States)

    2014-01-01

    A method for identifying stopped pions in a high-resolution scintillator bar detector is presented. I apply my technique to measure the axial mass MΔAfor production of the Δ(1232) resonance by neutrino, with the result MΔA = 1.16±0.20 GeV (68% CL) (limited by statistics). The result is produced from the measured spectrum of reconstructed momentum-transfer Q2. I proceed by varying the value of MΔA in a Rein-Sehgal-based Monte Carlo to produce the best agreement, using shape only (not normalization). The consistency of this result with recent reanalyses of previous bubble-chamber experiments is discussed.

  4. An architecture for integrating planar and 3D cQED devices

    Energy Technology Data Exchange (ETDEWEB)

    Axline, C.; Reagor, M.; Heeres, R.; Reinhold, P.; Wang, C.; Shain, K.; Pfaff, W.; Chu, Y.; Frunzio, L.; Schoelkopf, R. J. [Department of Applied Physics, Yale University, New Haven, Connecticut 06511 (United States)

    2016-07-25

    Numerous loss mechanisms can limit coherence and scalability of planar and 3D-based circuit quantum electrodynamics (cQED) devices, particularly due to their packaging. The low loss and natural isolation of 3D enclosures make them good candidates for coherent scaling. We introduce a coaxial transmission line device architecture with coherence similar to traditional 3D cQED systems. Measurements demonstrate well-controlled external and on-chip couplings, a spectrum absent of cross-talk or spurious modes, and excellent resonator and qubit lifetimes. We integrate a resonator-qubit system in this architecture with a seamless 3D cavity, and separately pattern a qubit, readout resonator, Purcell filter, and high-Q stripline resonator on a single chip. Device coherence and its ease of integration make this a promising tool for complex experiments.

  5. Resonance computations for cells with fuel annuli

    International Nuclear Information System (INIS)

    Hwang, R.N.; Gelbard, E.M.

    1990-01-01

    Two methods have been developed for the computation of resonance integrals in cells containing annular fuel regions. Both are based on rational approximations. One is a generalization of a one-term rational approximation method developed by Segev for a cell with a single fuel annulus. The second modifies the earlier Chen-Gelbard two-term method originally used for double-heterogeneity calculations. Both methods were tested, in cells with two fuel annuli, for various U 235 and U 238 resonances. Both gives resonance integrals accurate enough for practical purposes. The two-term fits are substantially more accurate in some NR cases, but are somewhat more difficult to correct for finite resonance widths. 8 refs., 4 tabs

  6. Measurement of the resonant and CP components in $\\overline{B}^0\\rightarrow J/\\psi \\pi^+\\pi^-$ decays

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Balagura, Vladislav; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Bauer, Thomas; Bay, Aurelio; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; van den Brand, Johannes; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Callot, Olivier; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel; Caponio, Francesco; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carranza-Mejia, Hector; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coca, Cornelia; Coco, Victor; Cogan, Julien; Cogneras, Eric; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Esen, Sevda; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farry, Stephen; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Giani', Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, Vladimir; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gordon, Hamish; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hartmann, Thomas; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jezabek, Marek; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanciotti, Elisa; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Guoming; Lohn, Stefan; Longstaff, Iain; Longstaff, Ian; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Manca, Giulia; Mancinelli, Giampiero; Manzali, Matteo; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Molina Rodriguez, Josue; Monteil, Stephane; Moran, Dermot; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Muresan, Raluca; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Powell, Andrew; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Alexander; Rinnert, Kurt; Rives Molina, Vincente; Roa Romero, Diego; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruffini, Fabrizio; Ruiz, Hugo; Ruiz Valls, Pablo; Sabatino, Giovanni; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sapunov, Matvey; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Senderowska, Katarzyna; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spinella, Franco; Spradlin, Patrick; Stagni, Federico; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teodorescu, Eliza; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Webber, Adam Dane; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wu, Suzhi; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Feng; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2014-01-01

    The resonant structure of the reaction $\\overline{B}^0\\rightarrow J/\\psi \\pi^+\\pi^-$ is studied using data from 3 fb$^{-1}$ of integrated luminosity collected by the LHCb experiment, one-third at 7 Tev center-of-mass energy and the remainder at 8 Tev. The invariant mass of the $\\pi^+\\pi^-$ pair and three decay angular distributions are used to determine the fractions of the resonant and non-resonant components. Six interfering $\\pi^+\\pi^-$ states: $\\rho(770)$, $f_0(500)$, $f_2(1270)$, $\\rho(1450)$, $\\omega(782)$ and $\\rho(1700)$ are required to give a good description of invariant mass spectra and decay angular distributions. The positive and negative CP fractions of each of the resonant final states are determined. The $f_0(980)$ meson is not seen and the upper limit on its presence, compared with the observed $f_0(500)$ rate, is inconsistent with a model of tetraquark substructure for these scalar mesons at the eight standard deviation level. In the $q\\overline{q}$ model, the absolute value of the mixing an...

  7. Membrane metamaterial resonators with a sharp resonance: A comprehensive study towards practical terahertz filters and sensors

    Directory of Open Access Journals (Sweden)

    Yongyao Chen

    2012-06-01

    Full Text Available We investigate the resonant properties of high quality-factor membrane-based metamaterial resonators functioning in the terahertz regime. A number of factors, including the resonator geometry, dielectric loss, and most importantly the membrane thickness are found to extensively influence the resonance strength and quality factor of the sharp resonance. Further studies on the membrane thickness-dependent-sensitivity for sensing applications reveal that high quality-factor membrane metamaterials with a moderate thickness ranging from 10 to 50 μm are the most promising option towards developing realistic integrated terahertz filters and sensors.

  8. Inverse Landau-Zener-Stuckelberg interferometry for the measurement of a resonator's state using a qubit

    Science.gov (United States)

    Shevchenko, Sergey; Ashhab, Sahel; Nori, Franco

    2013-03-01

    We consider theoretically a superconducting qubit - nanomechanical resonator system, which was realized recently by LaHaye et al. [Nature 459, 960 (2009)]. We formulate and solve the inverse Landau-Zener-Stuckelberg problem, where we assume the driven qubit's state to be known (i.e. measured by some other device) and aim to find the parameters of the qubit's Hamiltonian. In particular, for our system the qubit's bias is defined by the nanomechanical resonator's displacement. This may provide a tool for monitoring the nanomechanical resonator 's position. [S. N. Shevchenko, S. Ashhab, and F. Nori, Phys. Rev. B 85, 094502 (2012).

  9. Inelastic scattering in resonant tunneling

    DEFF Research Database (Denmark)

    Wingreen, Ned S.; Jacobsen, Karsten Wedel; Wilkins, John W.

    1989-01-01

    The exact resonant-tunneling transmission probability for an electron interacting with phonons is presented in the limit that the elastic coupling to the leads is independent of energy. The phonons produce transmission sidebands but do not affect the integrated transmission probability or the esc......The exact resonant-tunneling transmission probability for an electron interacting with phonons is presented in the limit that the elastic coupling to the leads is independent of energy. The phonons produce transmission sidebands but do not affect the integrated transmission probability...

  10. Elastic-properties measurement at high temperatures through contact resonance atomic force microscopy

    DEFF Research Database (Denmark)

    Marinello, Francesco; Pezzuolo, Andrea; Carmignato, Simone

    2015-01-01

    fast direct and non-destructive measurement of Young's modulus and related surface parameters.In this work an instrument set up for Contact Resonance Atomic Force Microscopy is proposed, where the sample with is coupled to a heating stage and a piezoelectric transducer directly vibrate the cantilever...

  11. Resonantly enhanced collisional ionization measurements of radionuclides

    International Nuclear Information System (INIS)

    Whitaker, T.J.; Bushaw, B.A.; Gerke, G.K.

    1986-01-01

    The authors developed a new laser technique to analyze for radionuclides at extremely low levels. The technique, called resonantly enhanced collisional ionization (RECI), uses two nitrogen-laser pumped dye lasers to excite the target isotope to a high-energy Rydberg state. Atoms in these Rydberg states (within a few hundred wavenumbers in energy from the ionization threshold) efficiently ionize upon colliding with an inert gas and the ions can be detected by conventional means. The principal advantage of resonantly-enhanced collisional ionization is the extreme sensitivity coupled with its relative simplicity and low cost. Actinides typically have an ionization potential of about 6eV (uranium I.P. = 6.2 eV, plutonium I.P. = 5.7 eV). Two-step laser excitation to a state just below threshold requires wavelengths in the blue region of the visible spectrum. They showed that when both steps in the excitation process are resonant steps, relatively low-power lasers can populate the Rydberg state with almost unit efficiency. This is because the resonant excitations have much larger cross-sections than do photoionization processes. They also demonstrated that a few torr of a buffer gas will cause most of the excited-state atoms to be ionized

  12. Neutron Activation Resonance Integrals of 64Zn, 68Zn, 85Rb, 100Mo, 102Ru, 113In, 123Sb, and 180Hf

    International Nuclear Information System (INIS)

    Ricabarra, M. D.; Turjanski, R.; Ricabarra, G. H.

    1969-01-01

    The ratio of resonance integral to thermal activation cross sections of the isotopes 64 Zn, 68 Zn, 85 Rb, 100 Mo, 102 Ru, 113 In, 123 Sb, and 180 Hf relative to gold has been determined by measuring cadmium ratios. The standard gold or a secondary standard was mixed uniformly in the samples and the activities resolved with a lithium-drift germanium γ-ray spectrometer. Expressed as Westcott S 0 values the results were: 64 Zn = 2.06 ± 0.03, 68 Zn = 3.72 ± 0.14, 85 Rb = 18.4 ± 0.6, 100 Mo = 21.7 ± 0.8, 102 Ru = 3.76 ± 0.03, 113 In = 24.7 ± 0.5, 123 Sb = 28.3 ± 2.1, 180 Hf = 2.17 ± 0.09. All measurements are relative to S 0 = 17.7 for gold. (author)

  13. Measurements of radial profiles of ion cyclotron resonance heating on the tandem mirror experiment

    International Nuclear Information System (INIS)

    Falabella, S.

    1988-01-01

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawrence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). This analyzer indicates an increase in ion temperature from ∼20 eV before ICRH to ∼150 eV during ICRH, with ∼60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial integral of n i T i as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma potential is seen to vary from axially peaked, to nearly flat, as the plasma conditions varied over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U

  14. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  15. Particle diffusion from resonance islands in Aladdin at SRC

    International Nuclear Information System (INIS)

    Liu, J.; Crosbie, E.; Teng, L.; Bridges, J.; Ciarlette, D.; Kustom, R.; Voss, D.; Mills, F.; Borland, M.; Symon, K.

    1993-01-01

    The dynamics of the beam in the resonance islands was studied on the electron storage ring Aladdin at the Synchrotron Radiation Center (SRC). The authors especially studied the horizontal third- and fourth-integral resonances driven by sextupole fields in the first and second order. A fast kicker was fired to kick the beam into one of the outboard stable islands. The beam took on a quasi-Gaussian distribution and slowly diffused out of the island. The diffusion rate and its dependence on the strengths of the driving sextupoles and the chromaticity sextupoles were measured by tracing the resonance peak of the betatron oscillation on the spectrum analyzer. Beam positions were also recorded through the data acquisition device which was locked by a pulse-delay circuitry. Interesting results are shown and compared with numerical calculations

  16. Particle diffusion from resonance islands in Aladdin at SRC

    International Nuclear Information System (INIS)

    Liu, J.; Crosbie, E.; Teng, L.; Bridges, J.; Ciarlette, D.; Kustom, R.; Voss, D.; Mills, F.; Borland, M.; Symon, K.

    1993-01-01

    The dynamics of the beam in the resonance islands was studied on the electron storage ring Aladdin at the Synchrotron Radiation Center (SRC). The authors especially studied the horizontal third- and fourth-integral resonances driven by sextupole fields in the first and second order. A fast kicker was fired to kick the beam into one of the outboard stable islands. The beam took on a quasi-Gaussian distribution and slowly diffused out of the island. The diffusion rate and its dependence on the strengths of the driving sextupoles and the chromaticity sextupoles were measured by tracing the resonance peak of the betatron oscillation on the spectrum analyzer. Beam positions were also recorded through the data acquisition device which was clocked by a pulse-delay circuitry. Interesting results are shown and compared with numerical calculations

  17. Resonance parameters of the 6.67-, 20.9-, and 36.8-eV levels in 238U

    International Nuclear Information System (INIS)

    Olsen, D.K.; de Saussure, G.; Perez, R.B.; Difilippo, F.C.

    1976-01-01

    The ENDF/B-IV 238 U cross sections (MAT-1262) yield an effective capture resonance integral in strongly self-shielded situations which is too high. This situation suggests that the ENDF/B capture widths for the first few s-wave levels may be too large. Recent ORELA measurements of transmission through 238 U have been analyzed with a multilevel formula to determine the parameters of the 6.67-, 20.9-, and 36.6-eV levels. These three levels provide 86 percent of the infinitely dilute capture resonance integral

  18. Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

    International Nuclear Information System (INIS)

    Costa, Juliana Dantas da; Sebastiane, Patricia Moreno; Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; D'Ippolito, Giuseppe

    2008-01-01

    Objective: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. Materials and methods: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imaging performed by two independent observers. Interobserver and inter method agreements were calculated using the intra class and Pearson's correlation coefficients. Results: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intra class coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intra class coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intra class coefficient: 91.4%; Pearson's coefficient: 93.4%). Conclusion: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The inter method agreement was low. (author)

  19. Transit time for resonant tunneling

    International Nuclear Information System (INIS)

    Garcia Calderon, G.; Rubio, A.

    1990-09-01

    This work considers properties of the partial widths in one dimensional elastic resonant tunneling in order to propose a transit-time τ tr = (h/2π)/Γ n T res ) where Γ n is the elastic width and T res the transmission coefficient at resonance energy. This time is interpreted as an average over the resonance energy width. It is shown that the tunneling current density integrated across a sharp resonance is inversely proportional to τ tr . This transit time may be much larger than the values predicted by other definitions. (author). 20 refs

  20. Indicators and Measurement Tools for Health Systems Integration: A Knowledge Synthesis

    Directory of Open Access Journals (Sweden)

    Esther Suter

    2017-11-01

    Full Text Available Background: Despite far reaching support for integrated care, conceptualizing and measuring integrated care remains challenging. This knowledge synthesis aimed to identify indicator domains and tools to measure progress towards integrated care. Methods: We used an established framework and a Delphi survey with integration experts to identify relevant measurement domains. For each domain, we searched and reviewed the literature for relevant tools. Findings: From 7,133 abstracts, we retrieved 114 unique tools. We found many quality tools to measure care coordination, patient engagement and team effectiveness/performance. In contrast, there were few tools in the domains of performance measurement and information systems, alignment of organizational goals and resource allocation. The search yielded 12 tools that measure overall integration or three or more indicator domains. Discussion: Our findings highlight a continued gap in tools to measure foundational components that support integrated care. In the absence of such targeted tools, “overall integration” tools may be useful for a broad assessment of the overall state of a system. Conclusions: Continued progress towards integrated care depends on our ability to evaluate the success of strategies across different levels and context. This study has identified 114 tools that measure integrated care across 16 domains, supporting efforts towards a unified measurement framework.

  1. Indicators and Measurement Tools for Health Systems Integration: A Knowledge Synthesis

    Science.gov (United States)

    Oelke, Nelly D.; da Silva Lima, Maria Alice Dias; Stiphout, Michelle; Janke, Robert; Witt, Regina Rigatto; Van Vliet-Brown, Cheryl; Schill, Kaela; Rostami, Mahnoush; Hepp, Shelanne; Birney, Arden; Al-Roubaiai, Fatima; Marques, Giselda Quintana

    2017-01-01

    Background: Despite far reaching support for integrated care, conceptualizing and measuring integrated care remains challenging. This knowledge synthesis aimed to identify indicator domains and tools to measure progress towards integrated care. Methods: We used an established framework and a Delphi survey with integration experts to identify relevant measurement domains. For each domain, we searched and reviewed the literature for relevant tools. Findings: From 7,133 abstracts, we retrieved 114 unique tools. We found many quality tools to measure care coordination, patient engagement and team effectiveness/performance. In contrast, there were few tools in the domains of performance measurement and information systems, alignment of organizational goals and resource allocation. The search yielded 12 tools that measure overall integration or three or more indicator domains. Discussion: Our findings highlight a continued gap in tools to measure foundational components that support integrated care. In the absence of such targeted tools, “overall integration” tools may be useful for a broad assessment of the overall state of a system. Conclusions: Continued progress towards integrated care depends on our ability to evaluate the success of strategies across different levels and context. This study has identified 114 tools that measure integrated care across 16 domains, supporting efforts towards a unified measurement framework. PMID:29588637

  2. Propagation of Nuclear Data Uncertainties in Integral Measurements by Monte-Carlo Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Noguere, G.; Bernard, D.; De Saint-Jean, C. [CEA Cadarache, 13 - Saint Paul lez Durance (France)

    2006-07-01

    Full text of the publication follows: The generation of Multi-group cross sections together with relevant uncertainties is fundamental to assess the quality of integral data. The key information that are needed to propagate the microscopic experimental uncertainties to macroscopic reactor calculations are (1) the experimental covariance matrices, (2) the correlations between the parameters of the model and (3) the covariance matrices for the multi-group cross sections. The propagation of microscopic errors by Monte-Carlo technique was applied to determine the accuracy of the integral trends provided by the OSMOSE experiment carried out in the MINERVE reactor of the CEA Cadarache. The technique consists in coupling resonance shape analysis and deterministic codes. The integral trend and its accuracy obtained on the {sup 237}Np(n,{gamma}) reaction will be presented. (author)

  3. A fully packaged micromachined single crystalline resonant force sensor

    Energy Technology Data Exchange (ETDEWEB)

    Cavalloni, C.; Gnielka, M.; Berg, J. von [Kistler Instrumente AG, Winterthur (Switzerland); Haueis, M.; Dual, J. [ETH Zuerich, Inst. of Mechanical Systems, Zuerich (Switzerland); Buser, R. [Interstate Univ. of Applied Science Buchs, Buchs (Switzerland)

    2001-07-01

    In this work a fully packaged resonant force sensor for static load measurements is presented. The working principle is based on the shift of the resonance frequency in response to the applied load. The heart of the sensor, the resonant structure, is fabricated by micromachining using single crystalline silicon. To avoid creep and hysteresis and to minimize temperature induced stress the resonant structure is encapsulated using an all-in-silicon solution. This means that the load coupling, the excitation of the microresonator and the detection of the oscillation signal are integrated in only one single crystalline silicon chip. The chip is packaged into a specially designed housing made of steel which has been designed with respect to application in harsh environments. The unloaded sensor has an initial frequency of about 22,5 kHz. The sensitivity amounts to 26 Hz/N with a linearity error significantly less than 0,5%FSO. (orig.)

  4. Towards an interpretive measurement framework to assess the levels of integrated and integrative thinking within organisations

    Directory of Open Access Journals (Sweden)

    Daniel Schörger

    2015-07-01

    Full Text Available This research study is located within the context of corporate reporting and is relevant for the agenda of sustainability and sustainable development. The specific context for this study is the South African mining industry, within which three units in the form of three companies, were chosen to provide a coherent case for this study. The sample for the analysis is based on the integrated reports of these companies for the years 2012 and 2013. This gives this research a total sample size of six reports. Based on the research findings an initial interpretive measurement framework to assess the levels of capital integration has been theorised which enables the various stakeholders of an organisation to assess the integrated and integrative thinking capabilities. The level of integration is represented as a maturity scale on which integrated thinking is associated with the lower levels, while integrative thinking is attributed to higher levels of maturity. In the elaborated framework, integrated thinking is perceived as being a prerequisite for integrative thinking. The practical implication of this study is that it provides a potential measurement framework for various organisational stakeholders, including investors, to assess the thinking capabilities that are more likely to lead to long term financial stability and sustainability. The value of this research study is that it provides an initial step towards measuring the level of integrated and integrative thinking capabilities within organisations where no such measurement framework currently exists. The limitations and implications of this research study are that the interpretive measurement framework represents merely an initial step and an ongoing working hypothesis which requires further research to develop its maturity and usefulness.

  5. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  6. Broadband Acoustic Resonance Dissolution Spectroscopy (BARDS): A rapid test for enteric coating thickness and integrity of controlled release pellet formulations.

    Science.gov (United States)

    Alfarsi, Anas; Dillon, Amy; McSweeney, Seán; Krüse, Jacob; Griffin, Brendan; Devine, Ken; Sherry, Patricia; Henken, Stephan; Fitzpatrick, Stephen; Fitzpatrick, Dara

    2018-04-12

    There are no rapid dissolution based tests for determining coating thickness, integrity and drug concentration in controlled release pellets either during production or post-production. The manufacture of pellets requires several coating steps depending on the formulation. The sub-coating and enteric coating steps typically take up to six hours each followed by additional drying steps. Post production regulatory dissolution testing also takes up to six hours to determine if the batch can be released for commercial sale. The thickness of the enteric coating is a key factor that determines the release rate of the drug in the gastro-intestinal tract. Also, the amount of drug per unit mass decreases with increasing thickness of the enteric coating. In this study, the coating process is tracked from start to finish on an hourly basis by taking samples of pellets during production and testing those using BARDS (Broadband Acoustic Resonance Dissolution Spectroscopy). BARDS offers a rapid approach to characterising enteric coatings with measurements based on reproducible changes in the compressibility of a solvent due to the evolution of air during dissolution. This is monitored acoustically via associated changes in the frequency of induced acoustic resonances. A steady state acoustic lag time is associated with the disintegration of the enteric coatings in basic solution. This lag time is pH dependent and is indicative of the rate at which the coating layer dissolves. BARDS represents a possible future surrogate test for conventional USP dissolution testing as its data correlates directly with the thickness of the enteric coating, its integrity and also with the drug loading as validated by HPLC. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Measurement and resonance analysis of neutron transmissions through four samples of 238U

    International Nuclear Information System (INIS)

    Olsen, D.K.; de Saussure, G.; Perez, R.B.; Difilippo, F.C.; Ingle, R.W.

    1977-01-01

    Accurate total and partial cross sections for 238 U are important for nuclear reactor design. In the resolved resonance region, energies below 4.0 keV, these cross sections are described in terms of individual resonance parameters of which the neutron widths in the 1.5 to 4.0 keV region from various workers appear discrepant. In order to determine these widths, (0.880 to 100.0 keV) neutron transmissions through 0.076, 0.254, 1.080, and 3.620 cm thick enriched 238 U samples were measured, and (0.880 to 100.0 keV) range transmissions were analyzed

  8. Measuring brain atrophy with a generalized formulation of the boundary shift integral.

    Science.gov (United States)

    Prados, Ferran; Cardoso, Manuel Jorge; Leung, Kelvin K; Cash, David M; Modat, Marc; Fox, Nick C; Wheeler-Kingshott, Claudia A M; Ourselin, Sebastien

    2015-01-01

    Brain atrophy measured using structural magnetic resonance imaging (MRI) has been widely used as an imaging biomarker for disease diagnosis and tracking of pathologic progression in neurodegenerative diseases. In this work, we present a generalized and extended formulation of the boundary shift integral (gBSI) using probabilistic segmentations to estimate anatomic changes between 2 time points. This method adaptively estimates a non-binary exclusive OR region of interest from probabilistic brain segmentations of the baseline and repeat scans to better localize and capture the brain atrophy. We evaluate the proposed method by comparing the sample size requirements for a hypothetical clinical trial of Alzheimer's disease to that needed for the current implementation of BSI as well as a fuzzy implementation of BSI. The gBSI method results in a modest but reduced sample size, providing increased sensitivity to disease changes through the use of the probabilistic exclusive OR region. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. DC superconducting quantum interference device usable in nuclear quadrupole resonance and zero field nuclear magnetic spectrometers

    Science.gov (United States)

    Fan, Non Q.; Clarke, John

    1993-01-01

    A spectrometer for measuring the nuclear quadrupole resonance spectra or the zero-field nuclear magnetic resonance spectra generated by a sample is disclosed. The spectrometer uses an amplifier having a dc SQUID operating in a flux-locked loop for generating an amplified output as a function of the intensity of the signal generated by the sample. The flux-locked loop circuit includes an integrator. The amplifier also includes means for preventing the integrator from being driven into saturation. As a result, the time for the flux-locked loop to recover from the excitation pulses generated by the spectrometer is reduced.

  10. Thermally actuated resonant silicon crystal nanobalances

    Science.gov (United States)

    Hajjam, Arash

    As the potential emerging technology for next generation integrated resonant sensors and frequency references as well as electronic filters, micro-electro-mechanical resonators have attracted a lot of attention over the past decade. As a result, a wide variety of high frequency micro/nanoscale electromechanical resonators have recently been presented. MEMS resonators, as low-cost highly integrated and ultra-sensitive mass sensors, can potentially provide new opportunities and unprecedented capabilities in the area of mass sensing. Such devices can provide orders of magnitude higher mass sensitivity and resolution compared to Film Bulk Acoustic resonators (FBAR) or the conventional quartz and Surface Acoustic Wave (SAW) resonators due to their much smaller sizes and can be batch-fabricated and utilized in highly integrated large arrays at a very low cost. In this research, comprehensive experimental studies on the performance and durability of thermally actuated micromechanical resonant sensors with frequencies up to tens of MHz have been performed. The suitability and robustness of the devices have been demonstrated for mass sensing applications related to air-borne particles and organic gases. In addition, due to the internal thermo-electro-mechanical interactions, the active resonators can turn some of the consumed electronic power back into the mechanical structure and compensate for the mechanical losses. Therefore, such resonators can provide self-sustained-oscillation without the need for any electronic circuitry. This unique property has been deployed to demonstrate a prototype self-sustained sensor for air-borne particle monitoring. I have managed to overcome one of the obstacles for MEMS resonators, which is their relatively poor temperature stability. This is a major drawback when compared with the conventional quartz crystals. A significant decrease of the large negative TCF for the resonators has been attained by doping the devices with a high

  11. Turbulent stress measurements with phase-contrast magnetic resonance through tilted slices

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Jordan; Soederberg, Daniel; Lundell, Fredrik [Linne FLOW Centre, KTH Mechanics, Stockholm (Sweden); Swerin, Agne [SP Technical Research Institute of Sweden-Chemistry, Materials and Surfaces, Stockholm (Sweden); KTH Royal Institute of Technology, Surface and Corrosion Science, Stockholm (Sweden)

    2017-05-15

    Aiming at turbulent measurements in opaque suspensions, a simplistic methodology for measuring the turbulent stresses with phase-contrast magnetic resonance velocimetry is described. The method relies on flow-compensated and flow-encoding protocols with the flow encoding gradient normal to the slice. The experimental data is compared with direct numerical simulations (DNS), both directly but also, more importantly, after spatial averaging of the DNS data that resembles the measurement and data treatment of the experimental data. The results show that the most important MRI data (streamwise velocity, streamwise variance and Reynolds shear stress) is reliable up to at least anti r = 0.75 without any correction, paving the way for dearly needed turbulence and stress measurements in opaque suspensions. (orig.)

  12. Optical and magnetic resonance measurements of a segmented poly(ester urethane)

    International Nuclear Information System (INIS)

    Cooke, D.W.; Muenchausen, R.E.; Bennett, B.L.; Orler, E.B.; Wrobleski, D.A.; Smith, M.E.; Jahan, M.S.; Thomas, D.E.

    1999-01-01

    X-ray-induced damage in Estane(registered trademark)5703 has been studied by luminescence, optical absorption and electron spin resonance techniques in the temperature interval ∼10-300 K. Molecular motion of the polymer soft segment, as determined by viscoelastic measurements, is correlated with features in the glow curve, indicating charge detrapping via thermal destruction of cavity traps. Spectral emission is characterized by four Lorentzian bands with maxima at 2.38, 2.55, 2.74 and 2.93 eV, which are attributed to triplet-to-singlet electronic transitions of the phenyl group in the polymer hard segment. Absorption peaks at 3.97, 4.29 and 4.46 eV are also assigned to transitions within this group. Several radicals with overlapping resonances are induced at 35 K, which, with increasing temperature, evolve into the relatively stable peroxy free-radical at room temperature

  13. Integrated Microfluidic Sensor System with Magnetostrictive Resonators

    KAUST Repository

    Liang, Cai; Kosel, Jü rgen; Gooneratne, Chinthaka

    2011-01-01

    The present embodiments describe a method that integrates a magnetostrictive sensor with driving and detecting elements into a microfluidic chip to detect a chemical, biochemical or biomedical species. These embodiments may also measure the properties of a fluid such as viscosity, pH values. The whole system can be referred to lab-on-a-chip (LOC) or micro-total-analysis-systems (.mu.TAS). In particular, this present embodiments include three units, including a microfluidics unit, a magnetostrictive sensor, and driving/detecting elements. An analyzer may also be provided to analyze an electrical signal associated with a feature of a target specimen.

  14. Integrated Microfluidic Sensor System with Magnetostrictive Resonators

    KAUST Repository

    Liang, Cai

    2011-12-08

    The present embodiments describe a method that integrates a magnetostrictive sensor with driving and detecting elements into a microfluidic chip to detect a chemical, biochemical or biomedical species. These embodiments may also measure the properties of a fluid such as viscosity, pH values. The whole system can be referred to lab-on-a-chip (LOC) or micro-total-analysis-systems (.mu.TAS). In particular, this present embodiments include three units, including a microfluidics unit, a magnetostrictive sensor, and driving/detecting elements. An analyzer may also be provided to analyze an electrical signal associated with a feature of a target specimen.

  15. Measurements of (p,γ) resonance strengths in the s-d shell

    NARCIS (Netherlands)

    Engelbertink, G.A.P.; Endt, P.M.

    1966-01-01

    Resonace strengths of selected resonances in the Ep=0.3−2.1 MeV region in the (p, γ) reactions on 23Na, 24–24Mg, 27Al, 28–30Si, 31P, 32, 34S, 35, 37Cl, 39, 41K and 40Ca are compared through relative yield measurements, using targets of many different chemical compounds, each containing at least two

  16. Real analysis measure theory, integration, and Hilbert spaces

    CERN Document Server

    Stein, Elias M

    2005-01-01

    Real Analysis is the third volume in the Princeton Lectures in Analysis, a series of four textbooks that aim to present, in an integrated manner, the core areas of analysis. Here the focus is on the development of measure and integration theory, differentiation and integration, Hilbert spaces, and Hausdorff measure and fractals. This book reflects the objective of the series as a whole: to make plain the organic unity that exists between the various parts of the subject, and to illustrate the wide applicability of ideas of analysis to other fields of mathematics and science. After

  17. Financial integration in the European Union. Measurement and determination

    NARCIS (Netherlands)

    Lemmen, J.J.G.

    1996-01-01

    The first part of this study addresses the measurement of financial integration in the European Union (EU). First, we present empirical evidence on the degree of financial integration as measured with interest parity conditions. Second, the study applies an error-correction model of

  18. Enhanced photoluminescence from ring resonators in hydrogenated amorphous silicon thin films at telecommunications wavelengths.

    Science.gov (United States)

    Patton, Ryan J; Wood, Michael G; Reano, Ronald M

    2017-11-01

    We report enhanced photoluminescence in the telecommunications wavelength range in ring resonators patterned in hydrogenated amorphous silicon thin films deposited via low-temperature plasma enhanced chemical vapor deposition. The thin films exhibit broadband photoluminescence that is enhanced by up to 5 dB by the resonant modes of the ring resonators due to the Purcell effect. Ellipsometry measurements of the thin films show a refractive index comparable to crystalline silicon and an extinction coefficient on the order of 0.001 from 1300 nm to 1600 nm wavelengths. The results are promising for chip-scale integrated optical light sources.

  19. Flexible optical network components based on densely integrated microring resonators

    NARCIS (Netherlands)

    Geuzebroek, D.H.

    2005-01-01

    This thesis addresses the design, realization and characterization of reconfigurable optical network components based on multiple microring resonators. Since thermally tunable microring resonators can be used as wavelength selective space switches, very compact devices with high complexity and

  20. Integral Plus Resonant Sliding Mode Direct Power Control for VSC-HVDC Systems under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Weipeng Yang

    2017-10-01

    Full Text Available An integral plus resonant sliding mode direct power control (IRSMC DPC strategy for voltage source converter high voltage direct current (VSC-HVDC systems under unbalanced grid voltage conditions is proposed in this paper. Through detailed instantaneous power flow analysis, a generalized power compensation method, by which the ratio between the amplitude of active and reactive power ripples can be controlled continuously, is obtained. This enables the system to provide flexible power control, so that the desired performance of the system on both the ac and dc sides can be attained under different operating conditions. When the grid voltage is unbalanced, one or both of the active and reactive power terms contain ripples, oscillating at twice the grid frequency, to obtain non-distorted ac current. A power controller consisting of the proportional, integral and resonant control laws is designed using the sliding mode control approach, to achieve accurate power control objective. Simulation studies on a two-terminal VSC-HVDC system using MATLAB/SIMULINK (R2013b, Mathworks, Natick, MA, USA are conducted to verify the effectiveness of the IRSMC DPC strategy. The results show that this strategy ensures satisfactory performance of the system over a wide range of operating conditions.

  1. Volume measurement of multiple sclerosis lesions with magnetic resonance images

    International Nuclear Information System (INIS)

    Wicks, D.A.G.; Tofts, P.S.; Miller, D.H.; Du Boulay, G.H.; Feinstein, A.; Harvey, I.; Brenner, R.; McDonald, W.I.; Sacares, R.P.

    1992-01-01

    The ability to visualise multiple sclerosis lesions in vivo with magnetic resonance imaging suggests an important role in monitoring the course of the disease. In order to help the long-term assessment of prospective treatments, a semi-automated technique for measuring lesion volume has been developed to provide a quantitative index of disease progression. Results are presented from a preliminary study with a single patient and compared to measurements taken from lesion outlines traced by a neuroradiologist, two neurologists and a technician. The semi-automated technique achieved a precision of 6% compared to a range of 12-33% for the manual tracing method. It also reduced the human interaction time from at least 60 min to 15 min. (orig.)

  2. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  3. Postmortem magnetic resonance imaging: Reproducing typical autopsy heart measurements.

    Science.gov (United States)

    Ampanozi, Garyfalia; Hatch, Gary M; Flach, Patricia M; Thali, Michael J; Ruder, Thomas D

    2015-11-01

    The aim of this study was to evaluate the utility of cardiac postmortem magnetic resonance (PMMR) to perform routine measurements of the ventricular wall thicknesses and the heart valves and to assess if imaging measurements are consistent with traditional autopsy measurements. In this retrospective study, 25 cases with cardiac PMMR and subsequent autopsy were included. The thicknesses of the myocardial walls as well as the circumferences of all heart valves were measured on cardiac PMMR and compared to autopsy measurements. Paired samples T-test and the Wilcoxon-Signed rank test, were used to compare autopsy and cardiac PMMR measurements. For exploring correlations, the Pearson's Correlation coefficient and the Spearman's Rho test were used. Cardiac PMMR measurements of the aortic and pulmonary valve circumferences showed no significant differences from autopsy measurements. The mitral and tricuspid valves circumferences differed significantly from autopsy measurements. Left myocardial and right myocardial wall thickness also differed significantly from autopsy measurements. Left and right myocardial wall thickness, and tricuspid valve circumference measurements on cardiac PMMR and autopsy, correlated strongly and significantly. Several PMMR measurements of cardiac parameters differ significantly from corresponding autopsy measurements. However, there is a strong correlation between cardiac PMMR measurements and autopsy measurements in the majority of these parameters. It is important to note that myocardial walls are thicker when measured in situ on cardiac PMMR than when measured at autopsy. Investigators using post-mortem MR should be aware of these differences in order to avoid false diagnoses of cardiac pathology based on cardiac PMMR. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Structural Integrity in Measures of Self Concept.

    Science.gov (United States)

    Stenner, A. Jackson; Katzenmeyer, W.G.

    Structural integrity of a measure is defined in terms of its replicability, constancy, invariance, and stability. Work completed in the development and validation of the Self Observation Scales (SOS) Primary Level (Stenner and Katzenmeyer, 1973) serves to illustrate one method of establishing structural integrity. The name of each scale of the SOS…

  5. Measurement of inverse pion photoproduction at energies spanning the N(1440) resonance

    International Nuclear Information System (INIS)

    Shafi, A.; Strakovsky, I.I.; Briscoe, W.J.; Arndt, R.A.; Bennhold, C.; Workman, R.L.; Prakhov, S.; Nefkens, B.M.K.; Clajus, M.; Marusic, A.; McDonald, S.; Phaisangittisakul, N.; Price, J.W.; Tippens, W.B.; Allgower, C.E.; Spinka, H.; Bekrenev, V.; Kulbardis, A.; Kozlenko, N.; Kruglov, S.

    2004-01-01

    Differential cross sections for the process π - p→γn have been measured at Brookhaven National Laboratory's Alternating Gradient Synchrotron with the Crystal Ball multiphoton spectrometer. Measurements were made at 18 pion momenta from 238 to 748 MeV/c, corresponding to E γ for the inverse reaction from 285 to 769 MeV. The data have been used to evaluate the γn multipoles in the vicinity of the N(1440) resonance. We compare our data and multipoles to previous determinations

  6. Some resonances between Eastern thought and Integral Biomathics in the framework of the WLIMES formalism for modeling living systems.

    Science.gov (United States)

    Simeonov, Plamen L; Ehresmann, Andrée C

    2017-12-01

    Forty-two years ago, Capra published "The Tao of Physics" (Capra, 1975). In this book (page 17) he writes: "The exploration of the atomic and subatomic world in the twentieth century has …. necessitated a radical revision of many of our basic concepts" and that, unlike 'classical' physics, the sub-atomic and quantum "modern physics" shows resonances with Eastern thoughts and "leads us to a view of the world which is very similar to the views held by mystics of all ages and traditions." This article stresses an analogous situation in biology with respect to a new theoretical approach for studying living systems, Integral Biomathics (IB), which also exhibits some resonances with Eastern thought. Stepping on earlier research in cybernetics 1 and theoretical biology, 2 IB has been developed since 2011 by over 100 scientists from a number of disciplines who have been exploring a substantial set of theoretical frameworks. From that effort, the need for a robust core model utilizing advanced mathematics and computation adequate for understanding the behavior of organisms as dynamic wholes was identified. At this end, the authors of this article have proposed WLIMES (Ehresmann and Simeonov, 2012), a formal theory for modeling living systems integrating both the Memory Evolutive Systems (Ehresmann and Vanbremeersch, 2007) and the Wandering Logic Intelligence (Simeonov, 2002b). Its principles will be recalled here with respect to their resonances to Eastern thought. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Integrating institutional bribery and behavioral measures of bribery

    OpenAIRE

    Rose, Richard; Peiffer, Caryn

    2016-01-01

    Bribery involves individuals exchanging material benefits for a service of a public institution. To understand the process of bribery we need to integrate measures of individual behaviour and institutional attributes rather than rely exclusively on surveys of individual perceptions and experience or macro-level corruption indexes of national institutions. This paper integrates institutional and behavioural measures to show that where you live and who you are have independent influence on whet...

  8. IMPLANTABLE RESONATORS – A TECHNIQUE FOR REPEATED MEASUREMENT OF OXYGEN AT MULTIPLE DEEP SITES WITH IN VIVO EPR

    Science.gov (United States)

    Li, Hongbin; Hou, Huagang; Sucheta, Artur; Williams, Benjamin B.; Lariviere, Jean P.; Khan, Nadeem; Lesniewski, Piotr N.; Swartz, Harold M.

    2013-01-01

    EPR oximetry using implantable resonators allow measurements at much deeper sites than are possible with surface resonators (> 80 mm vs. 10 mm) and have greater sensitivity at any depth. We report here the development of an improvement of the technique that now enables us to obtain the information from multiple sites and at a variety of depths. The measurements from the various sites are resolved using a simple magnetic field gradient. In the rat brain multi-probe implanted resonators measured pO2 at several sites simultaneously for over 6 months to record under normoxic, hypoxic and hyperoxic conditions. This technique also facilitates measurements in moving parts of the animal such as the heart, because the orientation of the paramagnetic material relative to the sensitive small loop is not altered by the motion. The measured response is very fast, enabling measurements in real time of physiological and pathological changes such as experimental cardiac ischemia in the mouse heart. The technique also is quite useful for following changes in tumor pO2, including applications with simultaneous measurements in tumors and adjacent normal tissues. PMID:20204802

  9. Direct measurement of resonance strengths in 34S(α ,γ )38Ar at astrophysically relevant energies using the DRAGON recoil separator

    Science.gov (United States)

    Connolly, D.; O'Malley, P. D.; Akers, C.; Chen, A. A.; Christian, G.; Davids, B.; Erikson, L.; Fallis, J.; Fulton, B. R.; Greife, U.; Hager, U.; Hutcheon, D. A.; Ilyushkin, S.; Laird, A. M.; Mahl, A.; Ruiz, C.

    2018-03-01

    Background: Nucleosynthesis of mid-mass elements is thought to occur under hot and explosive astrophysical conditions. Radiative α capture on 34S has been shown to impact nucleosynthesis in several such conditions, including core and shell oxygen burning, explosive oxygen burning, and type Ia supernovae. Purpose: Broad uncertainties exist in the literature for the strengths of three resonances within the astrophysically relevant energy range (ECM=1.94 -3.42 MeV at T =2.2 GK ). Further, there are several states in 38Ar within this energy range which have not been previously measured. This work aimed to remeasure the resonance strengths of states for which broad uncertainty existed as well as to measure the resonance strengths and energies of previously unmeasured states. Methods: Resonance strengths and energies of eight narrow resonances (five of which had not been previously studied) were measured in inverse kinematics with the DRAGON facility at TRIUMF by impinging an isotopically pure beam of 34S ions on a windowless 4He gas target. Prompt γ emissions of de-exciting 38Ar recoils were detected in an array of bismuth germanate scintillators in coincidence with recoil nuclei, which were separated from unreacted beam ions by an electromagnetic mass separator and detected by a time-of-flight system and a multianode ionization chamber. Results: The present measurements agree with previous results. Broad uncertainty in the resonance strength of the ECM=2709 keV resonance persists. Resonance strengths and energies were determined for five low-energy resonances which had not been studied previously, and their strengths were determined to be significantly weaker than those of previously measured resonances. Conclusions: The five previously unmeasured resonances were found not to contribute significantly to the total thermonuclear reaction rate. A median total thermonuclear reaction rate calculated using data from the present work along with existing literature values

  10. A semi-automated measuring system of brain diffusion and perfusion magnetic resonance imaging abnormalities in patients with multiple sclerosis based on the integration of coregistration and tissue segmentation procedures

    International Nuclear Information System (INIS)

    Revenaz, Alfredo; Ruggeri, Massimiliano; Laganà, Marcella; Bergsland, Niels; Groppo, Elisabetta; Rovaris, Marco; Fainardi, Enrico

    2016-01-01

    Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) abnormalities in patients with multiple sclerosis (MS) are currently measured by a complex combination of separate procedures. Therefore, the purpose of this study was to provide a reliable method for reducing analysis complexity and obtaining reproducible results. We implemented a semi-automated measuring system in which different well-known software components for magnetic resonance imaging (MRI) analysis are integrated to obtain reliable measurements of DWI and PWI disturbances in MS. We generated the Diffusion/Perfusion Project (DPP) Suite, in which a series of external software programs are managed and harmonically and hierarchically incorporated by in-house developed Matlab software to perform the following processes: 1) image pre-processing, including imaging data anonymization and conversion from DICOM to Nifti format; 2) co-registration of 2D and 3D non-enhanced and Gd-enhanced T1-weighted images in fluid-attenuated inversion recovery (FLAIR) space; 3) lesion segmentation and classification, in which FLAIR lesions are at first segmented and then categorized according to their presumed evolution; 4) co-registration of segmented FLAIR lesion in T1 space to obtain the FLAIR lesion mask in the T1 space; 5) normal appearing tissue segmentation, in which T1 lesion mask is used to segment basal ganglia/thalami, normal appearing grey matter (NAGM) and normal appearing white matter (NAWM); 6) DWI and PWI map generation; 7) co-registration of basal ganglia/thalami, NAGM, NAWM, DWI and PWI maps in previously segmented FLAIR space; 8) data analysis. All these steps are automatic, except for lesion segmentation and classification. We developed a promising method to limit misclassifications and user errors, providing clinical researchers with a practical and reproducible tool to measure DWI and PWI changes in MS

  11. Dynamic pressure probe response tests for robust measurements in periodic flows close to probe resonating frequency

    Science.gov (United States)

    Ceyhun Şahin, Fatma; Schiffmann, Jürg

    2018-02-01

    A single-hole probe was designed to measure steady and periodic flows with high fluctuation amplitudes and with minimal flow intrusion. Because of its high aspect ratio, estimations showed that the probe resonates at a frequency two orders of magnitude lower than the fast response sensor cut-off frequencies. The high fluctuation amplitudes cause a non-linear behavior of the probe and available models are neither adequate for a quantitative estimation of the resonating frequencies nor for predicting the system damping. Instead, a non-linear data correction procedure based on individual transfer functions defined for each harmonic contribution is introduced for pneumatic probes that allows to extend their operating range beyond the resonating frequencies and linear dynamics. This data correction procedure was assessed on a miniature single-hole probe of 0.35 mm inner diameter which was designed to measure flow speed and direction. For the reliable use of such a probe in periodic flows, its frequency response was reproduced with a siren disk, which allows exciting the probe up to 10 kHz with peak-to-peak amplitudes ranging between 20%-170% of the absolute mean pressure. The effect of the probe interior design on the phase lag and amplitude distortion in periodic flow measurements was investigated on probes with similar inner diameters and different lengths or similar aspect ratios (L/D) and different total interior volumes. The results suggest that while the tube length consistently sets the resonance frequency, the internal total volume affects the non-linear dynamic response in terms of varying gain functions. A detailed analysis of the introduced calibration methodology shows that the goodness of the reconstructed data compared to the reference data is above 75% for fundamental frequencies up to twice the probe resonance frequency. The results clearly suggest that the introduced procedure is adequate to capture non-linear pneumatic probe dynamics and to

  12. Reproducibility of 3.0 Tesla Magnetic Resonance Spectroscopy for Measuring Hepatic Fat Content

    NARCIS (Netherlands)

    van Werven, Jochem R.; Hoogduin, Johannes M.; Nederveen, Aart J.; van Vliet, Andre A.; Wajs, Ewa; Vandenberk, Petra; Stroes, Erik S. G.; Stoker, Jaap

    Purpose: To investigate reproducibility of proton magnetic resonance spectroscopy (H-1-MRS) to measure hepatic triglyceride content (HTGC). Materials and Methods: In 24 subjects, HTGC was evaluated using H-1-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of H-1-MRS

  13. High-Q microwave resonators with a photonic crystal structure

    International Nuclear Information System (INIS)

    Schuster, M.

    2001-08-01

    The localisation of electromagnetic energy at a defect in a photonic crystal is similar to a well known effect employed to construct high-Q microwave resonators: In a whispering gallery (WHG-) mode resonator the high Q-factor is achieved by localisation of the electromagnetic field energy by total reflection inside a disk made of dielectric material. The topic of this work is to demonstrate, that WHG-like modes can exist in an air defect in a photonic crystal that extends over several lattice periods; and that a high-Q microwave resonator can be made, utilizing these resonant modes. In numerical simulations, the transmission properties of a photonic crystal structure with hexagonal lattice symmetry have been investigated with a transfer-matrix-method. The eigenmodes of a defect structure in a photonic crystal have been calculated with a quasi-3d finite element integration technique. Experimental results confirm the simulated transmission properties and show the existence of modes inside the band gap, when a defect is introduced in the crystal. Resonator measurements show that a microwave resonator can be operated with those defect modes. It was found out that the main losses of the resonator were caused by bad microwave properties of the used dielectric material and by metal losses on the top and bottom resonator walls. Furthermore, it turned out that the detection of the photonic crystal defect mode was difficult because of a lack of simulation possibilities and high housing mode density in the resonator. (orig.)

  14. The influence of temperature in the characterization of nuclear resonance

    International Nuclear Information System (INIS)

    Campos, T.P.R. de; Martinez, A.S.

    1986-01-01

    A detailed analysis carried out to determine the temperature effects on the selection of different types of resonance for Resonance Integral calculations is presented. The type of approximation (WR, IR or NR) to be applied to the slowing down integral of the neutron balance equation depends on the relationship between the average energy lost by the neutron and the practical width. A method to include the temperature dependence in the ratio ΔE/GAMMA sub(p) is proposed. The results allowed us to show that this dependence negligence may lead to large errors in the Resonance Integral calculation. (Author) [pt

  15. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1980-01-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (author)

  16. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  17. Towards Motion-Insensitive Magnetic Resonance Imaging Using Dynamic Field Measurements

    DEFF Research Database (Denmark)

    Andersen, Mads

    motion during scanning and update the MRI scanner in real-time such that the imaging volume follows the head motion (prospective motion correction). In this thesis, prospective motion correction is presented where head motion is determined from signals measured with an electroencephalography (EEG) cap......Magnetic resonance imaging (MRI) of the brain is frequently used for both clinical diagnosis and brain research. This is due to the great versatility of the technique and the excellent ability to distinguish different types of soft tissue. The image quality is, however, heavily degraded when...

  18. Racetrack resonator as a loss measurement platform for photonic components.

    Science.gov (United States)

    Jones, Adam M; DeRose, Christopher T; Lentine, Anthony L; Starbuck, Andrew; Pomerene, Andrew T S; Norwood, Robert A

    2015-11-02

    This work represents the first complete analysis of the use of a racetrack resonator to measure the insertion loss of efficient, compact photonic components. Beginning with an in-depth analysis of potential error sources and a discussion of the calibration procedure, the technique is used to estimate the insertion loss of waveguide width tapers of varying geometry with a resulting 95% confidence interval of 0.007 dB. The work concludes with a performance comparison of the analyzed tapers with results presented for four taper profiles and three taper lengths.

  19. Capsular contracture and possible implant rupture: is magnetic resonance imaging useful?

    Science.gov (United States)

    Paetau, Alyssa A; McLaughlin, Sarah A; McNeil, Rebecca B; Sternberg, Erez; TerKonda, Sarvam P; Waldorf, James C; Perdikis, Galen

    2010-03-01

    Currently, magnetic resonance imaging is considered the accepted standard to evaluate breast implant integrity. To evaluate its utility in diagnosing ruptured silicone implants in the setting of capsular contracture and to correlate the preoperative assessment of implant integrity with or without magnetic resonance imaging with operative findings, 319 capsulectomies (171 patients with capsular contractures) were retrospectively reviewed. Preoperative magnetic resonance imaging was done on 160 implants, whereas the remaining 159 were evaluated using only physical examination and/or mammography. Postoperative results were analyzed to determine the sensitivity, specificity, and accuracy of preoperative magnetic resonance imaging in comparison with clinical and/or mammography evaluation alone. Although occasionally valuable, overall, preoperative magnetic resonance imaging was no more accurate than clinical evaluation with or without mammography in predicting implant status: magnetic resonance imaging 124 of 160 (78 percent) and clinical 121 of 159 (76 percent; p = 0.77). In the setting of capsular contracture, physical examination with or without mammogram is as accurate as magnetic resonance imaging in determining implant integrity. Although magnetic resonance imaging is a sensitive diagnostic tool, in symptomatic patients with capsular contracture, it cannot be viewed as infallible.

  20. Magnetic resonance: safety measures and biological effects

    International Nuclear Information System (INIS)

    Gordillo, I.; Lafuente, J.; Fernandez, C.; Barbero, M.J.; Cascon, E.

    1997-01-01

    The biological effects of electromagnetic fields is currently a subject of great controversy. For this reason, magnetic resonance imaging (MRI) and spectroscopy are constantly under investigation. The source of the risk in MRI is associated with the three types of electromagnetic radiation to which the patient is exposed: the static magnetic field, variable (gradient) magnetic fields and radiofrequency fields. Each is capable of producing significant biological effects when employed at sufficient intensity. Patients exposed to risk sources are those situated within the lines of force of the magnetic field, ellipsoid lines that are arranged around the magnet, representing the strength of the surrounding field. To date, at the intensity normally utilized in MRI(<2T) and respecting the field limit recommendations established by the US Food and Drug Administration (FDA) for clinical use of this technique no adverse secondary biological effects have been reported. The known biological effects and other possible secondary effects are reviewed, and the recommended safety measures are discussed. (Author)

  1. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1978-07-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (orig.) [de

  2. Path integral measure for first-order and metric gravities

    International Nuclear Information System (INIS)

    Aros, Rodrigo; Contreras, Mauricio; Zanelli, Jorge

    2003-01-01

    The equivalence between the path integrals for first-order gravity and the standard torsion-free, metric gravity in 3 + 1 dimensions is analysed. Starting with the path integral for first-order gravity, the correct measure for the path integral of the metric theory is obtained

  3. Two Novel Measurements for the Drive-Mode Resonant Frequency of a Micromachined Vibratory Gyroscope

    Directory of Open Access Journals (Sweden)

    Ancheng Wang

    2013-11-01

    Full Text Available To investigate the drive-mode resonance frequency of a micromachined vibratory gyroscope (MVG, one needs to measure it accurately and efficiently. The conventional approach to measure the resonant frequency is by performing a sweep frequency test and spectrum analysis. The method is time-consuming and inconvenient because of the requirements of many test points, a lot of data storage and off-line analyses. In this paper, we propose two novel measurement methods, the search method and track method, respectively. The former is based on the magnitude-frequency characteristics of the drive mode, utilizing a one-dimensional search technique. The latter is based on the phase-frequency characteristics, applying a feedback control loop. Their performances in precision, noise resistivity and efficiency are analyzed through detailed simulations. A test system is implemented based on a field programmable gate array (FPGA and experiments are carried out. By comparing with the common approach, feasibility and superiorities of the proposed methods are validated. In particular, significant efficiency improvements are achieved whereby the conventional frequency method consumes nearly 5,000 s to finish a measurement, while only 5 s is needed for the track method and 1 s for the search method.

  4. Split Hopkinson Resonant Bar Test for Sonic-Frequency Acoustic Velocity and Attenuation Measurements of Small, Isotropic Geologic Samples

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, S.

    2011-04-01

    Mechanical properties (seismic velocities and attenuation) of geological materials are often frequency dependent, which necessitates measurements of the properties at frequencies relevant to a problem at hand. Conventional acoustic resonant bar tests allow measuring seismic properties of rocks and sediments at sonic frequencies (several kilohertz) that are close to the frequencies employed for geophysical exploration of oil and gas resources. However, the tests require a long, slender sample, which is often difficult to obtain from the deep subsurface or from weak and fractured geological formations. In this paper, an alternative measurement technique to conventional resonant bar tests is presented. This technique uses only a small, jacketed rock or sediment core sample mediating a pair of long, metal extension bars with attached seismic source and receiver - the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the length and mass added to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The experiment can be conducted under elevated confining pressures up to tens of MPa and temperatures above 100 C, and concurrently with x-ray CT imaging. The described Split Hopkinson Resonant Bar (SHRB) test is applied in two steps. First, extension and torsion-mode resonance frequencies and attenuation of the entire system are measured. Next, numerical inversions for the complex Young's and shear moduli of the sample are performed. One particularly important step is the correction of the inverted Young's moduli for the effect of sample-rod interfaces. Examples of the application are given for homogeneous, isotropic polymer samples and a natural rock sample.

  5. Measurement of collisional self broadening of atomic resonance lines in selective reflection experiment

    International Nuclear Information System (INIS)

    Papoyan, A.V.

    1998-01-01

    A method is developed to measure directly the collisional self broadening rate for a dense atomic vapor from selective reflection spectra. Experimental realization for the atomic D 1 and D 2 resonance lines of Rb confirms a validity of the proposed technique. The deflection of experimentally measured values is not more than 20% from theoretically predicted ones in the atomic number density range of 7· 10 16 - 7· 10 17 cm - 3 . 10 refs

  6. Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays

    International Nuclear Information System (INIS)

    Sathishkumar, P.; Punyabrahma, P.; Sri Muthu Mrinalini, R.; Jayanth, G. R.

    2015-01-01

    A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array

  7. Silicon-Nitride-based Integrated Optofluidic Biochemical Sensors using a Coupled-Resonator Optical Waveguide

    Directory of Open Access Journals (Sweden)

    Jiawei eWANG

    2015-04-01

    Full Text Available Silicon nitride (SiN is a promising material platform for integrating photonic components and microfluidic channels on a chip for label-free, optical biochemical sensing applications in the visible to near-infrared wavelengths. The chip-scale SiN-based optofluidic sensors can be compact due to a relatively high refractive index contrast between SiN and the fluidic medium, and low-cost due to the complementary metal-oxide-semiconductor (CMOS-compatible fabrication process. Here, we demonstrate SiN-based integrated optofluidic biochemical sensors using a coupled-resonator optical waveguide (CROW in the visible wavelengths. The working principle is based on imaging in the far field the out-of-plane elastic-light-scattering patterns of the CROW sensor at a fixed probe wavelength. We correlate the imaged pattern with reference patterns at the CROW eigenstates. Our sensing algorithm maps the correlation coefficients of the imaged pattern with a library of calibrated correlation coefficients to extract a minute change in the cladding refractive index. Given a calibrated CROW, our sensing mechanism in the spatial domain only requires a fixed-wavelength laser in the visible wavelengths as a light source, with the probe wavelength located within the CROW transmission band, and a silicon digital charge-coupled device (CCD / CMOS camera for recording the light scattering patterns. This is in sharp contrast with the conventional optical microcavity-based sensing methods that impose a strict requirement of spectral alignment with a high-quality cavity resonance using a wavelength-tunable laser. Our experimental results using a SiN CROW sensor with eight coupled microrings in the 680nm wavelength reveal a cladding refractive index change of ~1.3 × 10^-4 refractive index unit (RIU, with an average sensitivity of ~281 ± 271 RIU-1 and a noise-equivalent detection limit (NEDL of 1.8 ×10^-8 RIU ~ 1.0 ×10^-4 RIU across the CROW bandwidth of ~1 nm.

  8. Photo-Detectors Integrated with Resonant Tunneling Diodes

    Directory of Open Access Journals (Sweden)

    José M. L. Figueiredo

    2013-07-01

    Full Text Available We report on photo-detectors consisting of an optical waveguide that incorporates a resonant tunneling diode (RTD. Operating at wavelengths around 1.55 μm in the optical communications C band we achieve maximum sensitivities of around 0.29 A/W which is dependent on the bias voltage. This is due to the nature of RTD nonlinear current-voltage characteristic that has a negative differential resistance (NDR region. The resonant tunneling diode photo-detector (RTD-PD can be operated in either non-oscillating or oscillating regimes depending on the bias voltage quiescent point. The oscillating regime is apparent when the RTD-PD is biased in the NDR region giving rise to electrical gain and microwave self-sustained oscillations Taking advantage of the RTD’s NDR distinctive characteristics, we demonstrate efficient detection of gigahertz (GHz modulated optical carriers and optical control of a RTD GHz oscillator. RTD-PD based devices can have applications in generation and optical control of GHz low-phase noise oscillators, clock recovery systems, and fiber optic enabled radio frequency communication systems.

  9. Development of the new gamma-ray calorimeter for the measurement of Pigmy Dipole Resonance

    Science.gov (United States)

    Shikata, Mizuki; Nakamura, Takashi; Togano, Yasuhiro; Kondo, Yosuke

    2014-09-01

    A new γ-ray calorimeter CATANA (CAlorimeter for gamma γ-ray Transition in Atomic Nuclei at high isospin Asynmetry) has been developed to measure highly excited states like the pygmy dipole resonance and the giant dipole resonance. CATANA will be used with the SAMURAI spectrometer at RIBF. The excitation energy spectrum will be reconstructed combining the invariant mass of the reaction products measured by SAMURAI and γ-ray energies from CATANA. CATANA has focused on achieving a high detection efficiency. It is calculated as 56% for 1 MeV γ-rays from beam with a velocity of β = 0.6. The CATANA array consists of 200 CsI(Na) crystals and covers angles from 10 to 120 degrees along the beam axis. In this study, we have tested prototype crystals of CATANA to evaluate their performance. A position dependence of the light input have been measured and compared with a Monte-Carlo simulation based on GEANT4. In this talk, we will report the design of CATANA and the result of the tests and the simulation.

  10. Resonance ionization scheme development for europium

    Energy Technology Data Exchange (ETDEWEB)

    Chrysalidis, K., E-mail: katerina.chrysalidis@cern.ch; Goodacre, T. Day; Fedosseev, V. N.; Marsh, B. A. [CERN (Switzerland); Naubereit, P. [Johannes Gutenberg-Universität, Institiut für Physik (Germany); Rothe, S.; Seiffert, C. [CERN (Switzerland); Kron, T.; Wendt, K. [Johannes Gutenberg-Universität, Institiut für Physik (Germany)

    2017-11-15

    Odd-parity autoionizing states of europium have been investigated by resonance ionization spectroscopy via two-step, two-resonance excitations. The aim of this work was to establish ionization schemes specifically suited for europium ion beam production using the ISOLDE Resonance Ionization Laser Ion Source (RILIS). 13 new RILIS-compatible ionization schemes are proposed. The scheme development was the first application of the Photo Ionization Spectroscopy Apparatus (PISA) which has recently been integrated into the RILIS setup.

  11. Direct application of the fast Fourier transform to open resonator calculations

    International Nuclear Information System (INIS)

    Johnson, M.M.

    1974-01-01

    It is shown that the integral equations for resonators can be written in the form of convolution integrals. A graph is given of the ratio of the time required to compute resonator eigenmodes using the fast Fourier transform (FFT) to the time required to evaluate the resonator convolution equation directly as a function of the number of mirror grid points. Computational savings made by using the FFT are discussed

  12. Assessment of tumor energy and oxygenation status by bioluminescence, nuclear magnetic resonance spectroscopy, and cryospectrophotometry.

    Science.gov (United States)

    Mueller-Klieser, W; Schaefer, C; Walenta, S; Rofstad, E K; Fenton, B M; Sutherland, R M

    1990-03-15

    The energy and oxygenation status of tumors from two murine sarcoma lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) were assessed using three independent techniques. Tumor energy metabolism was investigated in vivo by 31P nuclear magnetic resonance spectroscopy. After nuclear magnetic resonance measurements, tumors were frozen in liquid nitrogen to determine the tissue ATP concentration by imaging bioluminescence and to register the intracapillary oxyhemoglobin (HbO2) saturation using the cryospectrophotometric method. There was a positive correlation between the nucleoside triphosphate beta/total resonance ratio or a negative correlation between the Pi/total resonance ratio and the model ATP concentration obtained by bioluminescence, respectively. This was true for small tumors with no extended necrosis irrespective of tumor type. Moreover, a positive correlation was obtained between the HbO2 saturations and the ATP concentration measured with bioluminescence. The results demonstrate the potential of combined studies using noninvasive, integrating methods and high-resolution imaging techniques for characterizing the metabolic milieu in tumors.

  13. The flow measurement methods for the primary system of integral reactors

    International Nuclear Information System (INIS)

    Lee, J.; Seo, J. K.; Lee, D. J.

    2001-01-01

    It is the common features of the integral reactors that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integral reactors, and it also makes impossible measure the primary coolant flow rate. The objective of the study is to draw up the flow measurement methods for the primary system of integral reactors. As a result of the review, we have made a selection of the flow measurement method by pump speed, bt HBM, and by pump motor power as the flow measurement methods for the primary system of integral reactors. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for integral reactors, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  14. Development of atomic-beam resonance method to measure the nuclear moments of unstable nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, T., E-mail: sugimoto@ribf.riken.jp [SPring-8 (Japan); Asahi, K. [Tokyo Institute of Technology, Department of Physics (Japan); Kawamura, H.; Murata, J. [Rikkyo University, Department of Physics (Japan); Nagae, D.; Shimada, K. [Tokyo Institute of Technology, Department of Physics (Japan); Ueno, H.; Yoshimi, A. [RIKEN Nishina Center (Japan)

    2008-01-15

    We have been working on the development of a new technique of atomic-beam resonance method to measure the nuclear moments of unstable nuclei. In the present study, an ion-guiding system to be used as an atomic-beam source have been developed.

  15. A new way of controlling NesCOPOs (nested cavity doubly resonant OPO) for faster and more efficient high resolution spectrum measurement

    Science.gov (United States)

    Georges des Aulnois, Johann; Szymanski, Benjamin; Grimieau, Axel; Sillard, Léo.

    2018-02-01

    Optical Parametric Oscillator (OPO) is a well-known solution when wide tunability in the mid-infrared is needed. A specific design called NesCOPO (Nested Cavity doubly resonant OPO) is currently integrated in the X-FLR8 portable gas analyzer from Blue Industry and Science. Thanks to its low threshold this OPO can be pumped by a micro-chip nanosecond YAG (4 kHz repetition rate and a 30 GHz bandwidth). To achieve very high resolution spectra (10 pm of resolution or better), the emitted wavelength has to be finely controlled. Commercial Wavemeter do not meet price and compactness required in the context of an affordable and portable gas analyzer. To overcome this issue, Blue first integrated an active wavelength controller using multiple tunable Fabry-Perot (FP) interferometers. The required resolution was achieved at a 10 Hz measurement rate. We now present an enhanced Wavemeter architecture, based on fixed FP etalons, that is 100 times faster and 2 times smaller. We avoid having FP `blind zones' thanks to one source characteristic: the knowledge of the FSR (Free Spectral Range) of the OPO source and thus, the fact that only discrete wavelengths can be emitted. First results are displayed showing faster measurement for spectroscopic application, and potential future improvement of the device are discussed.

  16. Measurement of sup 15 O(. alpha. ,. gamma. ) sup 19 Ne resonance strengths

    Energy Technology Data Exchange (ETDEWEB)

    Magnus, P V; Smith, M S; Howard, A J; Parker, P D [Yale Univ., New Haven, CT (USA). Nuclear Structure Lab.; Champagne, A E [Princeton Univ., NJ (USA). Dept. of Physics

    1990-01-08

    States in {sup 19}Ne above the {sup 15}O+{alpha} threshold were populated by means of the {sup 19}F({sup 3}He,t){sup 19}Ne* reaction, and their alpha-particle decays to the {sup 15}O ground state were measured. The branching ratios {Gamma}{sub {alpha}}/{Gamma}{sub total} for the E{sub c.m.}=850-, 1020-, 1971-, 1183- and 1563-keV resonances in {sup 15}O+{alpha} were determined. This information together with alpha-particle and/or gamma-ray partial widths (determined from knowledge of these quantities for the mirror states in {sup 19}F) determines the strengths of these {sup 15}O({alpha},{gamma}){sup 19}Ne resonances and the {sup 15}O({alpha},{gamma}){sup 19}Ne reaction rate for temperatures between 7x10{sup 8} and 3x10{sup 9} K. (orig.).

  17. Decreased integration and information capacity in stroke measured by whole brain models of resting state activity.

    Science.gov (United States)

    Adhikari, Mohit H; Hacker, Carl D; Siegel, Josh S; Griffa, Alessandra; Hagmann, Patric; Deco, Gustavo; Corbetta, Maurizio

    2017-04-01

    While several studies have shown that focal lesions affect the communication between structurally normal regions of the brain, and that these changes may correlate with behavioural deficits, their impact on brain's information processing capacity is currently unknown. Here we test the hypothesis that focal lesions decrease the brain's information processing capacity, of which changes in functional connectivity may be a measurable correlate. To measure processing capacity, we turned to whole brain computational modelling to estimate the integration and segregation of information in brain networks. First, we measured functional connectivity between different brain areas with resting state functional magnetic resonance imaging in healthy subjects (n = 26), and subjects who had suffered a cortical stroke (n = 36). We then used a whole-brain network model that coupled average excitatory activities of local regions via anatomical connectivity. Model parameters were optimized in each healthy or stroke participant to maximize correlation between model and empirical functional connectivity, so that the model's effective connectivity was a veridical representation of healthy or lesioned brain networks. Subsequently, we calculated two model-based measures: 'integration', a graph theoretical measure obtained from functional connectivity, which measures the connectedness of brain networks, and 'information capacity', an information theoretical measure that cannot be obtained empirically, representative of the segregative ability of brain networks to encode distinct stimuli. We found that both measures were decreased in stroke patients, as compared to healthy controls, particularly at the level of resting-state networks. Furthermore, we found that these measures, especially information capacity, correlate with measures of behavioural impairment and the segregation of resting-state networks empirically measured. This study shows that focal lesions affect the brain's ability to

  18. Phase-conjugate resonant holographic interferometry applied to NH concentration measurements in a 2D diffusion flame

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Beaud, P; Frey, H M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    Resonant Holographic Interferometry is a method based on the anomalous dispersion of light having a frequency close to an electronic transition of a molecule. We propose a novel single-laser, two-colour setup for recording resonant holograms and apply it to 2D species concentration measurements. The second colour is generated by optical phase-conjugation from Stimulated Brillouin scattering in a cell. Phase-Conjugate Resonant Holographic Interferometry (PCRHI) is demonstrated in a 2D NH{sub 3}/O{sub 2} flame yielding interferograms that contain information on the NH radical distribution in the flame. Experimental results are quantified by applying a numerical computation of the Voigt profiles. (author) 1 fig., 3 refs.

  19. Waveguide Cavity Resonator as a Source of Optical Squeezing

    Science.gov (United States)

    Stefszky, M.; Ricken, R.; Eigner, C.; Quiring, V.; Herrmann, H.; Silberhorn, C.

    2017-04-01

    We present the generation of continuous-wave optical squeezing from a titanium-in-diffused lithium niobate waveguide resonator. We directly measure 2.9 ±0.1 dB of single-mode squeezing, which equates to a produced level of 4.9 ±0.1 dB after accounting for detection losses. This device showcases the current capabilities of this waveguide architecture and precipitates more complicated integrated continuous-wave quantum devices in the continuous-variable regime.

  20. An integrated optic ethanol vapor sensor based on a silicon-on-insulator microring resonator coated with a porous ZnO film.

    Science.gov (United States)

    Yebo, Nebiyu A; Lommens, Petra; Hens, Zeger; Baets, Roel

    2010-05-24

    Optical structures fabricated on silicon-on-insulator technology provide a convenient platform for the implementation of highly compact, versatile and low cost devices. In this work, we demonstrate the promise of this technology for integrated low power and low cost optical gas sensing. A room temperature ethanol vapor sensor is demonstrated using a ZnO nanoparticle film as a coating on an SOI micro-ring resonator of 5 microm in radius. The local coating on the ring resonators is prepared from colloidal suspensions of ZnO nanoparticles of around 3 nm diameter. The porous nature of the coating provides a large surface area for gas adsorption. The ZnO refractive index change upon vapor adsorption shifts the microring resonance through evanescent field interaction. Ethanol vapor concentrations down to 100 ppm are detected with this sensing configuration and a detection limit below 25 ppm is estimated.

  1. Measure of hydrogen concentration profile in materials by resonant nuclear reactions

    International Nuclear Information System (INIS)

    Livi, R.P.; Zawislak, F.C.; Acquadro, J.C.

    1986-01-01

    The technique for determining the profile of hydrogen concentration in proximities of the surface of materials, is presented. The preliminary measurements were done, using the Pelletron accelerator at Sao Paulo University (USP), in Brazil, for the resonant-nuclear reaction 1 H( 19 F, α γ) 16 O. By using this reaction the technique is sensitive for concentrations above 500 ppm, which could be reduced to 100 ppm through special shieldings and other techniques to reduce the background radiation. (M.C.K.) [pt

  2. Dynamic Measurement of Tumor Vascular Permeability and Perfusion using a Hybrid System for Simultaneous Magnetic Resonance and Fluorescence Imaging.

    Science.gov (United States)

    Ren, Wuwei; Elmer, Andreas; Buehlmann, David; Augath, Mark-Aurel; Vats, Divya; Ripoll, Jorge; Rudin, Markus

    2016-04-01

    Assessing tumor vascular features including permeability and perfusion is essential for diagnostic and therapeutic purposes. The aim of this study was to compare fluorescence and magnetic resonance imaging (MRI)-based vascular readouts in subcutaneously implanted tumors in mice by simultaneous dynamic measurement of tracer uptake using a hybrid fluorescence molecular tomography (FMT)/MRI system. Vascular permeability was measured using a mixture of extravascular imaging agents, GdDOTA and the dye Cy5.5, and perfusion using a mixture of intravascular agents, Endorem and a fluorescent probe (Angiosense). Dynamic fluorescence reflectance imaging (dFRI) was integrated into the hybrid system for high temporal resolution. Excellent correspondence between uptake curves of Cy5.5/GdDOTA and Endorem/Angiosense has been found with correlation coefficients R > 0.98. The two modalities revealed good agreement regarding permeability coefficients and centers-of-gravity of the imaging agent distribution. The FMT/dFRI protocol presented is able to accurately map physiological processes and poses an attractive alternative to MRI for characterizing tumor neoangiogenesis.

  3. Resonance parameters for measured keV neutron capture cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Musgrove, A.R. de L

    1969-05-01

    All available neutron capture cross sections in the keV region ({approx} to 100 keV) have been fitted with resonance parameters. Capture cross sections for nuclides with reasonably well known average s-wave parameters, but no measured cross section, have been calculated and tabulated using p-and d- wave strength functions interpolated between fitted values. Several of these nuclides are of interest in the theory of slow nucleosynthesis of heavy elements in stars, and the product of cosmic abundance (due to the s-process) and capture cross section at 30 keV has been plotted versus mass number. (author)

  4. Improving the wide resonance approximation

    International Nuclear Information System (INIS)

    Aboustta, Mohamed A.; Martinez, Aquilino S.

    1999-01-01

    A resonance is considered wide if its practical width, in energy, exceeds the average energy loss per collision, E(1-α A )/2, of the absorbing material. When the mass number, A, is taken infinite, the scattering produces only a change in the direction of motion of the neutron and not in its energy. Based on this assumption, the integral in the slowing-down equation describing the contribution of the resonant absorber is evaluated by taking its limit when α A →1. This work questions the necessity to take such a limit and shows that it is still possible to obtain a simple and more accurate expression for the integral without taking such limit

  5. Improving the wide resonance approximation

    Energy Technology Data Exchange (ETDEWEB)

    Aboustta, Mohamed A.; Martinez, Aquilino S

    1999-03-01

    A resonance is considered wide if its practical width, in energy, exceeds the average energy loss per collision, E(1-{alpha}{sub A})/2, of the absorbing material. When the mass number, A, is taken infinite, the scattering produces only a change in the direction of motion of the neutron and not in its energy. Based on this assumption, the integral in the slowing-down equation describing the contribution of the resonant absorber is evaluated by taking its limit when {alpha}{sub A}{yields}1. This work questions the necessity to take such a limit and shows that it is still possible to obtain a simple and more accurate expression for the integral without taking such limit.

  6. Laser-ultrasound spectroscopy apparatus and method with detection of shear resonances for measuring anisotropy, thickness, and other properties

    Science.gov (United States)

    Levesque, Daniel; Moreau, Andre; Dubois, Marc; Monchalin, Jean-Pierre; Bussiere, Jean; Lord, Martin; Padioleau, Christian

    2000-01-01

    Apparatus and method for detecting shear resonances includes structure and steps for applying a radiation pulse from a pulsed source of radiation to an object to generate elastic waves therein, optically detecting the elastic waves generated in the object, and analyzing the elastic waves optically detected in the object. These shear resonances, alone or in combination with other information, may be used in the present invention to improve thickness measurement accuracy and to determine geometrical, microstructural, and physical properties of the object. At least one shear resonance in the object is detected with the elastic waves optically detected in the object. Preferably, laser-ultrasound spectroscopy is utilized to detect the shear resonances.

  7. 2H{ 19F} REDOR for distance measurements in biological solids using a double resonance spectrometer

    Science.gov (United States)

    Grage, Stephan L.; Watts, Jude A.; Watts, Anthony

    2004-01-01

    A new approach for distance measurements in biological solids employing 2H{ 19F} rotational echo double resonance was developed and validated on 2H, 19F- D-alanine and an imidazopyridine based inhibitor of the gastric H +/K +-ATPase. The 2H- 19F double resonance experiments presented here were performed without 1H decoupling using a double resonance NMR spectrometer. In this way, it was possible to benefit from the relatively longer distance range of fluorine without the need of specialized fluorine equipment. A distance of 2.5 ± 0.3 Å was measured in the alanine derivative, indicating a gauche conformation of the two labels. In the case of the imidazopyridine compound a lower distance limit of 5.2 Å was determined and is in agreement with an extended conformation of the inhibitor. Several REDOR variants were compared, and their advantages and limitations discussed. Composite fluorine dephasing pulses were found to enhance the frequency bandwidth significantly, and to reduce the dependence of the performance of the experiment on the exact choice of the transmitter frequency.

  8. Synthesis of highly integrated optical network based on microdisk-resonator add-drop filters in silicon-on-insulator technology

    Science.gov (United States)

    Kaźmierczak, Andrzej; Dortu, Fabian; Giannone, Domenico; Bogaerts, Wim; Drouard, Emmanuel; Rojo-Romeo, Pedro; Gaffiot, Frederic

    2009-10-01

    We analyze a highly compact optical add-drop filter topology based on a pair of microdisk resonators and a bus waveguide intersection. The filter is further assessed on an integrated optical 4×4 network for optical on-chip communication. The proposed network structure, as compact as 50×50 μm, is fabricated in a CMOS-compatible process on a silicon-on-insulator (SOI) substrate. Finally, the experimental results demonstrate the proper operation of the fabricated devices.

  9. Measurement of single electron and nuclear spin states based on optically detected magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Berman, Gennady P [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Bishop, Alan R [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Chernobrod, Boris M [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hawley, Marilyn E [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Brown, Geoffrey W [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Tsifrinovich, Vladimir I [Polytechnic University, Brooklyn, NY 11201 (United States)

    2006-05-15

    A novel approach for measurement of single electron and nuclear spin states is suggested. Our approach is based on optically detected magnetic resonance in a nano-probe located at the apex of an AFM tip. The method provides single electron spin sensitivity with nano-scale spatial resolution.

  10. Measurement of single electron and nuclear spin states based on optically detected magnetic resonance

    International Nuclear Information System (INIS)

    Berman, Gennady P; Bishop, Alan R; Chernobrod, Boris M; Hawley, Marilyn E; Brown, Geoffrey W; Tsifrinovich, Vladimir I

    2006-01-01

    A novel approach for measurement of single electron and nuclear spin states is suggested. Our approach is based on optically detected magnetic resonance in a nano-probe located at the apex of an AFM tip. The method provides single electron spin sensitivity with nano-scale spatial resolution

  11. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  12. Measurement of resonances in 12 C + 4 He through inverse kinematics with thick targets

    International Nuclear Information System (INIS)

    Aguilera, E.F.; Lizcano, D.; Martinez Q, E.; Fernandez, M.C.; Murillo, G.; Goldberg, V.; Skorodumov, B.B.; Rogachev, G.

    2003-01-01

    The excitation function of elastic scattering for the system 12 C + 4 He to energy from 0.5 to 3.5 MeV in the center of mass system (c.m.) was measured. We use a gassy thick target and the technique of inverse kinematics which allows to make measurements at 180 degrees in c.m. Using the R matrix theory those was deduced parameters of the resonances and the results were compared with measurements reported in the literature made with other techniques. (Author)

  13. On Frequency Combs in Monolithic Resonators

    Science.gov (United States)

    Savchenkov, A. A.; Matsko, A. B.; Maleki, L.

    2016-06-01

    Optical frequency combs have become indispensable in astronomical measurements, biological fingerprinting, optical metrology, and radio frequency photonic signal generation. Recently demonstrated microring resonator-based Kerr frequency combs point the way towards chip scale optical frequency comb generator retaining major properties of the lab scale devices. This technique is promising for integrated miniature radiofrequency and microwave sources, atomic clocks, optical references and femtosecond pulse generators. Here we present Kerr frequency comb development in a historical perspective emphasizing its similarities and differences with other physical phenomena. We elucidate fundamental principles and describe practical implementations of Kerr comb oscillators, highlighting associated solved and unsolved problems.

  14. Optical Spring Effect in Micro-Bubble Resonators and Its Application for the Effective Mass Measurement of Optomechanical Resonant Mode

    OpenAIRE

    Zhenmin Chen; Xiang Wu; Liying Liu; Lei Xu

    2017-01-01

    In this work, we present a novel approach for obtaining the effective mass of mechanical vibration mode in micro-bubble resonators (MBRs). To be specific, the effective mass is deduced from the measurement of optical spring effect (OSE) in MBRs. This approach is demonstrated and applied to analyze the effective mass of hollow MBRs and liquid-filled MBRs, respectively. It is found that the liquid-filled MBRs has significantly stronger OSE and a less effective mass than hollow MBRs, both of the...

  15. A Novel Method for Measurements of the Penetration Depth of MgB2 Superconductor Films by Using Sapphire Resonators with Short-Circuited Parallel Plates

    International Nuclear Information System (INIS)

    Jung, Ho Sang; Lee, J. H.; Cho, Y. H.; Lee, Sang Young; Seong, W. K.; Lee, N. H.; Kang, W. N.

    2009-01-01

    We introduce a measurement method that enables to measure the penetration depth(λ) of superconductor films by using a short-ended parallel plate sapphire resonator. Variations in the (λof MgB 2 films could be measured down to the lowest temperature using a sapphire resonator with a YBa 2 Cu 3 O 7-x film at the bottom. A model equation of λλ 0 [1-(T/T c ) τ ] -1/2 for MgB 2 films appeared to describe the observed variations of the resonant frequency of the sapphire resonator with temperature, with λ 0 , τ and T c used as the fitting parameters.

  16. Calibrated high-precision 17O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance

    Directory of Open Access Journals (Sweden)

    E. J. Steig

    2014-08-01

    Full Text Available High-precision analysis of the 17O / 16O isotope ratio in water and water vapor is of interest in hydrological, paleoclimate, and atmospheric science applications. Of specific interest is the parameter 17O excess (Δ17O, a measure of the deviation from a~linear relationship between 17O / 16O and 18O / 16O ratios. Conventional analyses of Δ17O of water are obtained by fluorination of H2O to O2 that is analyzed by dual-inlet isotope ratio mass spectrometry (IRMS. We describe a new laser spectroscopy instrument for high-precision Δ17O measurements. The new instrument uses cavity ring-down spectroscopy (CRDS with laser-current-tuned cavity resonance to achieve reduced measurement drift compared with previous-generation instruments. Liquid water and water-vapor samples can be analyzed with a better than 8 per meg precision for Δ17O using integration times of less than 30 min. Calibration with respect to accepted water standards demonstrates that both the precision and the accuracy of Δ17O are competitive with conventional IRMS methods. The new instrument also achieves simultaneous analysis of δ18O, Δ17O and δD with precision of < 0.03‰, < 0.02 and < 0.2‰, respectively, based on repeated calibrated measurements.

  17. Measuring ac losses in superconducting cables using a resonant circuit:Resonant current experiment (RESCUE)

    DEFF Research Database (Denmark)

    Däumling, Manfred; Olsen, Søren Krüger; Rasmussen, Carsten

    1998-01-01

    be recorded using, for example, a digital oscilloscope. The amplitude decay of the periodic voltage or current accurately reflects the power loss in the system. It consists of two components-an ohmic purely exponential one (from leads, contacts, etc.), and a nonexponential component originating from......A simple way to obtain true ac losses with a resonant circuit containing a superconductor, using the decay of the circuit current, is described. For the measurement a capacitor is short circuited with a superconducting cable. Energy in the circuit is provided by either charging up the capacitors...... with a certain voltage, or letting a de flow in the superconductor. When the oscillations are started-either by opening a switch in case a de is flowing or by closing a switch to connect the charged capacitors with the superconductor-the current (via a Rogowski coil) or the voltage on the capacitor can...

  18. Calculation of Resonance Interaction Effects Using a Rational Approximation to the Symmetric Resonance Line Shape Function

    International Nuclear Information System (INIS)

    Haeggblom, H.

    1968-08-01

    The method of calculating the resonance interaction effect by series expansions has been studied. Starting from the assumption that the neutron flux in a homogeneous mixture is inversely proportional to the total cross section, the expression for the flux can be simplified by series expansions. Two types of expansions are investigated and it is shown that only one of them is generally applicable. It is also shown that this expansion gives sufficient accuracy if the approximate resonance line shape function is reasonably representative. An investigation is made of the approximation of the resonance shape function with a Gaussian function which in some cases has been used to calculate the interaction effect. It is shown that this approximation is not sufficiently accurate in all cases which can occur in practice. Then, a rational approximation is introduced which in the first order approximation gives the same order of accuracy as a practically exact shape function. The integrations can be made analytically in the complex plane and the method is therefore very fast compared to purely numerical integrations. The method can be applied both to statistically correlated and uncorrelated resonances

  19. Calculation of Resonance Interaction Effects Using a Rational Approximation to the Symmetric Resonance Line Shape Function

    Energy Technology Data Exchange (ETDEWEB)

    Haeggblom, H

    1968-08-15

    The method of calculating the resonance interaction effect by series expansions has been studied. Starting from the assumption that the neutron flux in a homogeneous mixture is inversely proportional to the total cross section, the expression for the flux can be simplified by series expansions. Two types of expansions are investigated and it is shown that only one of them is generally applicable. It is also shown that this expansion gives sufficient accuracy if the approximate resonance line shape function is reasonably representative. An investigation is made of the approximation of the resonance shape function with a Gaussian function which in some cases has been used to calculate the interaction effect. It is shown that this approximation is not sufficiently accurate in all cases which can occur in practice. Then, a rational approximation is introduced which in the first order approximation gives the same order of accuracy as a practically exact shape function. The integrations can be made analytically in the complex plane and the method is therefore very fast compared to purely numerical integrations. The method can be applied both to statistically correlated and uncorrelated resonances.

  20. Resonant tunneling measurements of size-induced strain relaxation

    Science.gov (United States)

    Akyuz, Can Deniz

    Lattice mismatch strain available in such semiconductor heterostructures as Si/SiGe or GaAs/AlGaAs can be employed to alter the electronic and optoelectronic properties of semiconductor structures and devices. When deep submicron structures are fabricated from strained material, strained layers relax by sidewall expansion giving rise to size- and geometry-dependent strain gradients throughout the structure. This thesis describes a novel experimental technique to probe the size-induced strain relaxation by studying the tunneling current characteristics of strained p-type Si/SiGe resonant tunneling diodes. Our current-voltage measurements on submicron strained p-Si/SiGe double- and triple-barrier resonant tunneling structures as a function of device diameter, D, provide experimental access to both the average strain relaxation (which leads to relative shifts in the tunneling current peak positions) and strain gradients (which give rise to a fine structure in the current peaks due to inhomogeneous strain-induced lateral quantization). We find that strain relaxation is significant, with a large fraction of the strain energy relaxed on average in D ≤ 0.25 m m devices. Further, the in-plane potentials that arise from inhomogeneous strain gradients are large. In the D ˜ 0.2 m m devices, the corresponding lateral potentials are approximately parabolic exceeding ˜ 25 meV near the perimeter. These potentials create discrete hole states in double-barrier structures (single well), and coupled hole states in triple-barrier structures (two wells). Our results are in excellent agreement with finite-element strain calculations in which the strained layers are permitted to relax to a state of minimum energy by sidewall expansion. Size-induced strain relaxation will undoubtedly become a serious technological issue once strained devices are scaled down to the deep submicron regime. Interestingly, our calculations predict and our measurements are consistent with the appearance of

  1. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  2. Use of microring resonators for biospecific interaction analysis

    Science.gov (United States)

    Chalyan, Tatevik; Besselink, Geert A. J.; Heideman, Rene G.; Pavesi, Lorenzo

    2017-08-01

    Integrated optical biosensors based on Mach-Zehnder Interferometers and Microring Resonators are widely used for food/drug monitoring and protein studies thank to their high intrinsic sensitivity, easy integration and miniaturization, and low cost.1, 2 In this study, we present a system to perform antibody interaction analysis using a photonic chip made of an array of six microring resonators (MRRs) based on the TriPleX platform. A compact system is presented where the input light is provided by a Vertical Cavity Surface Emitting Laser (VCSEL) pigtailed to a single mode fiber and operating at a ≍ 850nm wavelength. The output signal is detected by PIN photodetectors placed in the optical signal read-out module (the so-called OSROM) and processed by an easy-to-use Fourier Transform algorithm. Bulk sensitivity (Sb=98+/-2.1 nm/RIU) and Limit of Detection (LOD=(7.5+/- 0.5) x10-6 RIU) are measured and appeared to be very similar for the six MRRs on the same chip,3 which is an important property for multianalyte detection. An analysis of the anti-biotin interaction with immobilized biotin is performed by using different concentrations of anti-biotin antibody. The dependence of the resonance wavelength shift from the antibody concentration, as well as the association and the dissociation rate constants are calculated. For the average dissociation constant (KD) of anti-biotin antibody toward immobilized biotin, a value of (1.9+/-0.5) x10-7M is estimated, which is of the same order of magnitude of other published data.4 Furthermore, the specificity of the interaction is confirmed by using negative control antibodies and by performing competition with free, i.e., dissolved, biotin. In addition, the functional surface of the sensors could be regenerated for repeated measurements up to eight times by using 10 mM glycine/HCl pH 1.5.

  3. Measurement of gamma-ray multiplicity spectra and the alpha value for {sup 235}U resonances

    Energy Technology Data Exchange (ETDEWEB)

    Grigor` ev, Yu V [Institute of Physics and Power Engineering, Obninsk (Russian Federation); Georgiev, G P; Stanchik, Kh [Joint Inst. for Nuclear Research, Dubna (Russian Federation)

    1997-06-01

    Gamma spectra from 1 to 12 multiplicity were measured on th 500 m flight path of the IBR-30 reactor using a 16-section 32 L NaI(Tl) crystal scintillation detector able to hold 2 metallic samples of 90% {sup 235}U and 10% {sup 238}U 0.00137 atoms/b and 0.00411 atoms/b thick. Multiplicity spectra were obtained for resolved resonances in the E = 1-150 eV energy region. They were used to determine the value of {alpha} = {sigma}{sub {gamma}}/{sigma}{sub f} for 165 resonances of {sup 235}U. (author). 6 refs, 7 figs, 1 tab.

  4. Stieltjes-moment-theory technique for calculating resonance width's

    International Nuclear Information System (INIS)

    Hazi, A.U.

    1978-12-01

    A recently developed method for calculating the widths of atomic and molecular resonances is reviewed. The method is based on the golden-rule definition of the resonance width, GAMMA(E). The method uses only square-integrable, L 2 , basis functions to describe both the resonant and the non-resonant parts of the scattering wave function. It employs Stieltjes-moment-theory techniques to extract a continuous approximation for the width discrete representation of the background continuum. Its implementation requires only existing atomic and molecular structure codes. Many-electron effects, such as correlation and polarization, are easily incorporated into the calculation of the width via configuration interaction techniques. Once the width, GAMMA(E), has been determined, the energy shift can be computed by a straightforward evaluation of the required principal-value integral. The main disadvantage of the method is that it provides only the total width of a resonance which decays into more than one channel in a multichannel problem. A review of the various aspects of the theory is given first, and then representative results that have been obtained with this method for several atomic and molecular resonances are discussed. 28 references, 3 figures, 4 tables

  5. Electronics/avionics integrity - Definition, measurement and improvement

    Science.gov (United States)

    Kolarik, W.; Rasty, J.; Chen, M.; Kim, Y.

    The authors report on the results obtained from an extensive, three-fold research project: (1) to search the open quality and reliability literature for documented information relative to electronics/avionics integrity; (2) to interpret and evaluate the literature as to significant concepts, strategies, and tools appropriate for use in electronics/avionics product and process integrity efforts; and (3) to develop a list of critical findings and recommendations that will lead to significant progress in product integrity definition, measurement, modeling, and improvements. The research consisted of examining a broad range of trade journals, scientific journals, and technical reports, as well as face-to-face discussions with reliability professionals. Ten significant recommendations have been supported by the research work.

  6. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  7. Optimal distribution of integration time for intensity measurements in Stokes polarimetry.

    Science.gov (United States)

    Li, Xiaobo; Liu, Tiegen; Huang, Bingjing; Song, Zhanjie; Hu, Haofeng

    2015-10-19

    We consider the typical Stokes polarimetry system, which performs four intensity measurements to estimate a Stokes vector. We show that if the total integration time of intensity measurements is fixed, the variance of the Stokes vector estimator depends on the distribution of the integration time at four intensity measurements. Therefore, by optimizing the distribution of integration time, the variance of the Stokes vector estimator can be decreased. In this paper, we obtain the closed-form solution of the optimal distribution of integration time by employing Lagrange multiplier method. According to the theoretical analysis and real-world experiment, it is shown that the total variance of the Stokes vector estimator can be significantly decreased about 40% in the case discussed in this paper. The method proposed in this paper can effectively decrease the measurement variance and thus statistically improves the measurement accuracy of the polarimetric system.

  8. Amplitude saturation of MEMS resonators explained by autoparametric resonance

    International Nuclear Information System (INIS)

    Van der Avoort, C; Bontemps, J J M; Steeneken, P G; Le Phan, K; Van Beek, J T M; Van der Hout, R; Hulshof, J; Fey, R H B

    2010-01-01

    This paper describes a phenomenon that limits the power handling of MEMS resonators. It is observed that above a certain driving level, the resonance amplitude becomes independent of the driving level. In contrast to previous studies of power handling of MEMS resonators, it is found that this amplitude saturation cannot be explained by nonlinear terms in the spring constant or electrostatic force. Instead we show that the amplitude in our experiments is limited by nonlinear terms in the equation of motion which couple the in-plane length-extensional resonance mode to one or more out-of-plane (OOP) bending modes. We present experimental evidence for the autoparametric excitation of these OOP modes using a vibrometer. The measurements are compared to a model that can be used to predict a power-handling limit for MEMS resonators

  9. Amplitude saturation of MEMS resonators explained by autoparametric resonance

    Energy Technology Data Exchange (ETDEWEB)

    Van der Avoort, C; Bontemps, J J M; Steeneken, P G; Le Phan, K; Van Beek, J T M [NXP Research, Eindhoven (Netherlands); Van der Hout, R; Hulshof, J [Department of Mathematics, VU University—Faculty of Sciences, De Boelelaan 1081a, 1081 HV Amsterdam (Netherlands); Fey, R H B, E-mail: cas.van.der.avoort@nxp.com [Department of Mechanical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB, Eindhoven (Netherlands)

    2010-10-15

    This paper describes a phenomenon that limits the power handling of MEMS resonators. It is observed that above a certain driving level, the resonance amplitude becomes independent of the driving level. In contrast to previous studies of power handling of MEMS resonators, it is found that this amplitude saturation cannot be explained by nonlinear terms in the spring constant or electrostatic force. Instead we show that the amplitude in our experiments is limited by nonlinear terms in the equation of motion which couple the in-plane length-extensional resonance mode to one or more out-of-plane (OOP) bending modes. We present experimental evidence for the autoparametric excitation of these OOP modes using a vibrometer. The measurements are compared to a model that can be used to predict a power-handling limit for MEMS resonators.

  10. Magnetic resonance fingerprinting.

    Science.gov (United States)

    Ma, Dan; Gulani, Vikas; Seiberlich, Nicole; Liu, Kecheng; Sunshine, Jeffrey L; Duerk, Jeffrey L; Griswold, Mark A

    2013-03-14

    Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.

  11. A multilayered integrated sensor for three-dimensional, micro total analysis systems

    International Nuclear Information System (INIS)

    Xiao, Jing; Song, Fuchuan; Seo, Sang-Woo

    2013-01-01

    This paper presents a layer-by-layer integration approach of different functional devices and demonstrates a heterogeneously integrated optical sensor featuring a micro-ring resonator and a high-speed thin-film InGaAs-based photodetector co-integrated with a microfluidic droplet generation device. A thin optical device structure allows a seamless integration with other polymer-based devices on a silicon platform. The integrated sensor successfully demonstrates its transient measurement capability of two-phase liquid flow in a microfluidic droplet generation device. The proposed approach represents an important step toward fully integrated micro total analysis systems. (paper)

  12. Measurement of resonance parameters of orbitally excited narrow B0 mesons.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Akimoto, T; Albrow, M G; González, B Alvarez; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzurri, P; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Beringer, J; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burke, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cordelli, M; Cortiana, G; Cox, C A; Cox, D J; Crescioli, F; Almenar, C Cuenca; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; Derwent, P F; di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Elagin, A; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Genser, K; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heijboer, A; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhr, T; Kulkarni, N P; Kurata, M; Kusakabe, Y; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, E; Lee, H S; Lee, S W; Leone, S; Lewis, J D; Lin, C-S; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lucchesi, D; Luci, C; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Merkel, P; Mesropian, C; Miao, T; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moggi, N; Moon, C S; Moore, R; Morello, M J; Morlok, J; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Griso, S Pagan; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Rekovic, V; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Stuart, D; Suh, J S; Sukhanov, A; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Würthwein, F; Wynne, S M; Xie, S; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zhang, X; Zheng, Y; Zucchelli, S

    2009-03-13

    We report a measurement of resonance parameters of the orbitally excited (L=1) narrow B0 mesons in decays to B;{(*)+}pi;{-} using 1.7 fb;{-1} of data collected by the CDF II detector at the Fermilab Tevatron. The mass and width of the B_{2};{*0} state are measured to be m(B_{2};{*0})=5740.2_{-1.8};{+1.7}(stat)-0.8+0.9(syst) MeV/c;{2} and Gamma(B_{2};{*0})=22.7_{-3.2};{+3.8}(stat)-10.2+3.2(syst) MeV/c;{2}. The mass difference between the B_{2};{*0} and B10 states is measured to be 14.9_{-2.5};{+2.2}(stat)-1.4+1.2(syst) MeV/c;{2}, resulting in a B10 mass of 5725.3_{-2.2};{+1.6}(stat)-1.5+1.4(syst) MeV/c;{2}. This is currently the most precise measurement of the masses of these states and the first measurement of the B_{2};{*0} width.

  13. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  14. Josephson junctions array resonators

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, Oscar; Muppalla, Phani; Mirzaei, Iman; Kirchmair, Gerhard [Institute for Quantum Optics and Quantum Information, Innsbruck (Austria)

    2016-07-01

    We present an experimental analysis of the self- and cross-Kerr effect of extended plasma resonances in Josephson junction chains. The chain consists of 1600 individual junctions and we can measure quality factors in excess of 10000. The Kerr effect manifests itself as a frequency shift that depends linearly on the number of photons in a resonant mode. By changing the input power we are able to measure this frequency shift on a single mode (self-kerr). By changing the input power on another mode while measuring the same one, we are able to evaluate the cross-kerr effect. We can measure the cross-Kerr effect by probing the resonance frequency of one mode while exciting another mode of the array with a microwave drive.

  15. Towards integrating environmental performance in divisional performance measurement

    Directory of Open Access Journals (Sweden)

    Collins C Ngwakwe

    2014-08-01

    Full Text Available This paper suggests an integration of environmental performance measurement (EPM into conventional divisional financial performance measures as a catalyst to enhance managers’ drive toward cleaner production and sustainable development. The approach is conceptual and normative; and using a hypothetical firm, it suggests a model to integrate environmental performance measure as an ancillary to conventional divisional financial performance measures. Vroom’s motivation theory and other literature evidence indicate that corporate goals are achievable in an environment where managers’ efforts are recognised and thus rewarded. Consequently the paper suggests that environmentally motivated managers are important to propel corporate sustainability strategy toward desired corporate environmental governance and sustainable economic development. Thus this suggested approach modestly adds to existing environmental management accounting (EMA theory and literature. It is hoped that this paper may provide an agenda for further research toward a practical application of the suggested method in a firm.

  16. Magnetic resonance imaging-compatible tactile sensing device based on a piezoelectric array.

    Science.gov (United States)

    Hamed, Abbi; Masamune, Ken; Tse, Zion Tsz Ho; Lamperth, Michael; Dohi, Takeyoshi

    2012-07-01

    Minimally invasive surgery is a widely used medical technique, one of the drawbacks of which is the loss of direct sense of touch during the operation. Palpation is the use of fingertips to explore and make fast assessments of tissue morphology. Although technologies are developed to equip minimally invasive surgery tools with haptic feedback capabilities, the majority focus on tissue stiffness profiling and tool-tissue interaction force measurement. For greatly increased diagnostic capability, a magnetic resonance imaging-compatible tactile sensor design is proposed, which allows minimally invasive surgery to be performed under image guidance, combining the strong capability of magnetic resonance imaging soft tissue and intuitive palpation. The sensing unit is based on a piezoelectric sensor methodology, which conforms to the stringent mechanical and electrical design requirements imposed by the magnetic resonance environment The sensor mechanical design and the device integration to a 0.2 Tesla open magnetic resonance imaging scanner are described, together with the device's magnetic resonance compatibility testing. Its design limitations and potential future improvements are also discussed. A tactile sensing unit based on a piezoelectric sensor principle is proposed, which is designed for magnetic resonance imaging guided interventions.

  17. A cascade mechanism of three-particle resonance production

    International Nuclear Information System (INIS)

    Badalyan, A.M.; Polikarpov, M.I.; Simonov, Yu.A.

    1976-01-01

    We study the mechanism of the three-particle resonance production in a system consisting of a two-particle resonance and of one particle, the resonance and the particle permanently exchanging the decay product particle. The N/D method is used to show that the solution of the unitarity for the resonance-particle amplitude reduces to solving a one-dimensional nonsingular integral equation for the denominator of the amplitude D(y). The contribution from the right-hand cut of the exchange decay diagram is considered explicitly and the final equation contains only the integral over an arbitrary left-hand cut as in the case of the interaction amplitude of stable particles. It is as well shown that if only the right-hand cut is present, than the denominator D(y) for L=0 has no singularities, whereas the amplitude may have virtual or real poles at L=1

  18. Tunable superconducting resonators with integrated trap structures for coupling with ultracold atomic gases

    Energy Technology Data Exchange (ETDEWEB)

    Ferdinand, Benedikt; Wiedmaier, Dominik; Koelle, Dieter; Kleiner, Reinhold [Physikalisches Institut and Center for Quantum Science in LISA+, Universitaet Tuebingen (Germany); Bothner, Daniel [Physikalisches Institut and Center for Quantum Science in LISA+, Universitaet Tuebingen (Germany); Kavli Institute of Nanoscience, Delft University of Technology, Delft (Netherlands)

    2016-07-01

    We intend to investigate a hybrid quantum system where ultracold atomic gases play the role of a long-living quantum memory, coupled to a superconducting qubit via a coplanar waveguide transmission line resonator. As a first step we developed a resonator chip containing a Z-shaped trapping wire for the atom trap. In order to suppress parasitic resonances due to stray capacitances, and to achieve good ground connection we use hybrid superconductor - normal conductor chips. As an additional degree of freedom we add a ferroelectric capacitor making the resonators voltage-tunable. We furthermore show theoretical results on the expected coupling strength between resonator and atomic cloud.

  19. Electron paramagnetic resonance

    CERN Document Server

    Al'tshuler, S A

    2013-01-01

    Electron Paramagnetic Resonance is a comprehensive text on the field of electron paramagnetic resonance, covering both the theoretical background and the results of experiment. This book is composed of eight chapters that cover theoretical materials and experimental data on ionic crystals, since these are the materials that have been most extensively studied by the methods of paramagnetic resonance. The opening chapters provide an introduction to the basic principles of electron paramagnetic resonance and the methods of its measurement. The next chapters are devoted to the theory of spectra an

  20. Measuring cross-border regional integration with composite indicators

    DEFF Research Database (Denmark)

    Makkonen, Teemu

    2016-01-01

    Earlier quantitative studies on cross-border regional integration processes have commonly neglected science, technology and innovation (STI) indicators: even the most notable example of a composite indicator approach to measuring cross-border regional integration, i.e. the Oresund index, lacks...... a sub-category for STI. Consequently, by ignoring cross-border innovation and knowledge flows, the Oresund integration index fails to take into account one of the most important drivers of economic growth in cross-border regions. Therefore, a new composite STI indicator (sub-category) was introduced......-border regions....

  1. Resonant Magnetic Field Sensors Based On MEMS Technology

    Directory of Open Access Journals (Sweden)

    Elías Manjarrez

    2009-09-01

    Full Text Available Microelectromechanical systems (MEMS technology allows the integration of magnetic field sensors with electronic components, which presents important advantages such as small size, light weight, minimum power consumption, low cost, better sensitivity and high resolution. We present a discussion and review of resonant magnetic field sensors based on MEMS technology. In practice, these sensors exploit the Lorentz force in order to detect external magnetic fields through the displacement of resonant structures, which are measured with optical, capacitive, and piezoresistive sensing techniques. From these, the optical sensing presents immunity to electromagnetic interference (EMI and reduces the read-out electronic complexity. Moreover, piezoresistive sensing requires an easy fabrication process as well as a standard packaging. A description of the operation mechanisms, advantages and drawbacks of each sensor is considered. MEMS magnetic field sensors are a potential alternative for numerous applications, including the automotive industry, military, medical, telecommunications, oceanographic, spatial, and environment science. In addition, future markets will need the development of several sensors on a single chip for measuring different parameters such as the magnetic field, pressure, temperature and acceleration.

  2. Resonant Magnetic Field Sensors Based On MEMS Technology

    Science.gov (United States)

    Herrera-May, Agustín L.; Aguilera-Cortés, Luz A.; García-Ramírez, Pedro J.; Manjarrez, Elías

    2009-01-01

    Microelectromechanical systems (MEMS) technology allows the integration of magnetic field sensors with electronic components, which presents important advantages such as small size, light weight, minimum power consumption, low cost, better sensitivity and high resolution. We present a discussion and review of resonant magnetic field sensors based on MEMS technology. In practice, these sensors exploit the Lorentz force in order to detect external magnetic fields through the displacement of resonant structures, which are measured with optical, capacitive, and piezoresistive sensing techniques. From these, the optical sensing presents immunity to electromagnetic interference (EMI) and reduces the read-out electronic complexity. Moreover, piezoresistive sensing requires an easy fabrication process as well as a standard packaging. A description of the operation mechanisms, advantages and drawbacks of each sensor is considered. MEMS magnetic field sensors are a potential alternative for numerous applications, including the automotive industry, military, medical, telecommunications, oceanographic, spatial, and environment science. In addition, future markets will need the development of several sensors on a single chip for measuring different parameters such as the magnetic field, pressure, temperature and acceleration. PMID:22408480

  3. Coupled-resonator-induced plasmonic bandgaps.

    Science.gov (United States)

    Wang, Yujia; Sun, Chengwei; Gong, Qihuang; Chen, Jianjun

    2017-10-15

    By drawing an analogy with the conventional photonic crystals, the plasmonic bandgaps have mainly employed the periodic metallic structures, named as plasmonic crystals. However, the sizes of the plasmonic crystals are much larger than the wavelengths, and the large sizes considerably decrease the density of the photonic integration circuits. Here, based on the coupled-resonator effect, the plasmonic bandgaps are experimentally realized in the subwavelength waveguide-resonator structure, which considerably decreases the structure size to subwavelength scales. An analytic model and the phase analysis are established to explain this phenomenon. Both the experiment and simulation show that the plasmonic bandgap structure has large fabrication tolerances (>20%). Instead of the periodic metallic structures in the bulky plasmonic crystals, the utilization of the subwavelength plasmonic waveguide-resonator structure not only significantly shrinks the bandgap structure to be about λ 2 /13, but also expands the physics of the plasmonic bandgaps. The subwavelength dimension, together with the waveguide configuration and robust realization, makes the bandgap structure easy to be highly integrated on chips.

  4. A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes

    Directory of Open Access Journals (Sweden)

    Libo Zhao

    2016-06-01

    Full Text Available Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m3 to 900 kg/m3 and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail.

  5. Laser-polarized xenon-129 magnetic resonance spectroscopy and imaging. The development of a method for in vivo perfusion measurement

    Science.gov (United States)

    Rosen, Matthew Scot

    2001-07-01

    This thesis presents in vivo nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) studies with laser-polarized 129Xe delivered to living rats by inhalation and transported to tissue via blood flow. The results presented herein include the observation, assignment, and dynamic measurement of 129Xe resonances in the brain and body, the first one- and two-dimensional chemical-shift-resolved images of 129Xe in blood, tissue, and gas in the thorax, and the first images of 129Xe in brain tissue. These results establish that laser-polarized 129Xe can be used as a magnetic resonance tracer in vivo. NMR resonances at 0, 191, 198, and 209 ppm relative to the 129 Xe gas resonance are observed in the rat thorax and assigned to 129Xe in gas, fat, tissue, and blood respectively. Resonances at 189, 192, 195, 198, and 209 ppm are observed in the brain, and the 195 and 209 ppm resonances are assigned to 129Xe in grey matter, and blood, respectively. The design and construction of a laser-polarized 129Xe production and delivery system is described. This system produces liter-volumes of laser- polarized 129Xe by spin-exchange optical- pumping. It represented an order of magnitude increase over previously reported production volumes of polarized 129Xe. At approximately 3-7% polarization, 157 cc-atm of xenon is produced and stored as ice every 5 minutes. This reliable, effective, and simple production method for large volumes of 129Xe can be applied to other areas of research involving the use of laser-polarized noble gases. A model of the in vivo transport of laser polarized 129Xe to tissue under realistic experimental NMR conditions is described. Appropriate control of the NMR parameters is shown to allow tissue perfasion and 129Xe tissue T1 to be extracted from measurement of the steady-state 129Xe tissue signal. In vivo rodent 129Xe NMR results are used to estimate the signal-to-noise ratio of this technique, and an inhaled 30% xenon/70% O2 mixture polarized to 5

  6. Impedance Matching Antenna-Integrated High-Efficiency Energy Harvesting Circuit

    Science.gov (United States)

    Shinki, Yuharu; Shibata, Kyohei; Mansour, Mohamed

    2017-01-01

    This paper describes the design of a high-efficiency energy harvesting circuit with an integrated antenna. The circuit is composed of series resonance and boost rectifier circuits for converting radio frequency power into boosted direct current (DC) voltage. The measured output DC voltage is 5.67 V for an input of 100 mV at 900 MHz. Antenna input impedance matching is optimized for greater efficiency and miniaturization. The measured efficiency of this antenna-integrated energy harvester is 60% for −4.85 dBm input power and a load resistance equal to 20 kΩ at 905 MHz. PMID:28763043

  7. Impedance Matching Antenna-Integrated High-Efficiency Energy Harvesting Circuit

    Directory of Open Access Journals (Sweden)

    Yuharu Shinki

    2017-08-01

    Full Text Available This paper describes the design of a high-efficiency energy harvesting circuit with an integrated antenna. The circuit is composed of series resonance and boost rectifier circuits for converting radio frequency power into boosted direct current (DC voltage. The measured output DC voltage is 5.67 V for an input of 100 mV at 900 MHz. Antenna input impedance matching is optimized for greater efficiency and miniaturization. The measured efficiency of this antenna-integrated energy harvester is 60% for −4.85 dBm input power and a load resistance equal to 20 kΩ at 905 MHz.

  8. Impedance Matching Antenna-Integrated High-Efficiency Energy Harvesting Circuit.

    Science.gov (United States)

    Shinki, Yuharu; Shibata, Kyohei; Mansour, Mohamed; Kanaya, Haruichi

    2017-08-01

    This paper describes the design of a high-efficiency energy harvesting circuit with an integrated antenna. The circuit is composed of series resonance and boost rectifier circuits for converting radio frequency power into boosted direct current (DC) voltage. The measured output DC voltage is 5.67 V for an input of 100 mV at 900 MHz. Antenna input impedance matching is optimized for greater efficiency and miniaturization. The measured efficiency of this antenna-integrated energy harvester is 60% for -4.85 dBm input power and a load resistance equal to 20 kΩ at 905 MHz.

  9. Measuring fragmentation in dissociative identity disorder: the integration measure and relationship to switching and time in therapy.

    Science.gov (United States)

    Barlow, M Rose; Chu, James A

    2014-01-01

    Some people with dissociative identity disorder (DID) have very little communication or awareness among the parts of their identity, while others experience a great deal of cooperation among alternate identities. Previous research on this topic has been sparse. Currently, there is no empirical measure of integration versus fragmentation in a person with DID. In this study, we report the development of such a measure. The goal of this study was to pilot the integration measure (IM) and to address its psychometric properties and relationships to other measures. The IM is the first standardized measure of integration in DID. Eleven women with DID participated in an experiment that included a variety of tasks. They filled out questionnaires about trauma and dissociation as well as the IM. They also provided verbal results about switching among alternate identities during the study sessions. Participants switched among identities an average of 5.8 times during the first session, and switching was highly correlated with trauma. Integration was related to switching, though this relationship may be non-linear. Integration was not related to time in psychotherapy. The IM provides a useful beginning to quantify and study integration and fragmentation in DID. Directions for future research are also discussed, including expanding the IM from this pilot. The IM may be useful in treatment settings to assess progress or change over time.

  10. Erbium-doped fiber ring resonator for resonant fiber optical gyro applications

    Science.gov (United States)

    Li, Chunming; Zhao, Rui; Tang, Jun; Xia, Meijing; Guo, Huiting; Xie, Chengfeng; Wang, Lei; Liu, Jun

    2018-04-01

    This paper reports a fiber ring resonator with erbium-doped fiber (EDF) for resonant fiber optical gyro (RFOG). To analyze compensation mechanism of the EDF on resonator, a mathematical model of the erbium-doped fiber ring resonator (EDFRR) is established based on Jones matrix to be followed by the design and fabrication of a tunable EDFRR. The performances of the fabricated EDFRR were measured and the experimental Q-factor of 2 . 47 × 108 and resonant depth of 109% were acquired separately. Compared with the resonator without the EDF, the resonant depth and Q-factor of the proposed device are increased by 2.5 times and 14 times, respectively. A potential optimum shot noise limited resolution of 0 . 042∘ / h can be obtained for the RFOG, which is promising for low-cost and high precise detection.

  11. Magnetic resonance electrical impedance tomography for measuring electrical conductivity during electroporation

    International Nuclear Information System (INIS)

    Kranjc, M; Miklavčič, D; Bajd, F; Serša, I

    2014-01-01

    The electroporation effect on tissue can be assessed by measurement of electrical properties of the tissue undergoing electroporation. The most prominent techniques for measuring electrical properties of electroporated tissues have been voltage–current measurement of applied pulses and electrical impedance tomography (EIT). However, the electrical conductivity of tissue assessed by means of voltage–current measurement was lacking in information on tissue heterogeneity, while EIT requires numerous additional electrodes and produces results with low spatial resolution and high noise. Magnetic resonance EIT (MREIT) is similar to EIT, as it is also used for reconstruction of conductivity images, though voltage and current measurements are not limited to the boundaries in MREIT, hence it yields conductivity images with better spatial resolution. The aim of this study was to investigate and demonstrate the feasibility of the MREIT technique for assessment of conductivity images of tissues undergoing electroporation. Two objects were investigated: agar phantoms and ex vivo liver tissue. As expected, no significant change of electrical conductivity was detected in agar phantoms exposed to pulses of all used amplitudes, while a considerable increase of conductivity was measured in liver tissue exposed to pulses of different amplitudes. (paper)

  12. The LIPAR-5 resonance parameter library

    International Nuclear Information System (INIS)

    Abagyan, L.P.

    1997-08-01

    The LIPAR-5 neutron resolved resonance parameter library has been elaborated. It contains data for 94 isotopes. The author's evaluations are included in LIPAR. Other authors' results are also included after re-evaluation. The codes used for the evaluation are described briefly. Tables of results are included for every isotope: the boundaries of the resolved resonance region, the numbers of s- and p-resonances, the thermal neutron partial cross-sections and the resonance integrals. The parameters are presented in ENDF/B-6 format. LIPAR is part of the nuclear data library of the MCU Monte Carlo code for neutron transport calculations. LIPAR was verified by comparing the benchmark experiment and Monte Carlo calculation results. (author). 44 refs, 6 tabs

  13. Measurement of line overlap for resonant photopumping of transitions in neonlike ions by nickel-like ions

    International Nuclear Information System (INIS)

    Elliott, S.; Beiersdorfer, P.; Nilsen, J.

    1993-01-01

    A measurement is made of the 3d-4f transition energies in the Ni-like ions Re 47+ , Ir 49+ , Pt 50+ , Au 51+ , and Bi 55+ and the 2p-4d transition energies in the Ne-like ions Br 25+ , Kr 26+ , Rb 27+ , and Y 29+ using the Livermore electron-beam ion trap. The ions studied are candidates for an x-ray laser scheme based on resonant photopumping which predicts lasing among the 3p-3s transitions in a Ne-like ion. The results of the measurements are compared to multiconfiguration Dirac-Fock calculations and systematic differences are found. The best resonance is found for the Pt-Rb pair at 2512 eV, whose energies differ by 0.4±0.1 eV, that is, by only 160 ppm

  14. Laser resonant ionization spectroscopy and laser-induced resonant fluorescence spectra of samarium atom

    International Nuclear Information System (INIS)

    Jin, Changtai

    1995-01-01

    We have measured new high-lying levels of Sm atom by two-colour resonant photoionisation spectroscopy; we have observed the isotope shifts of Sm atom by laser-induced resonant fluorescence spectroscopy; the lifetime of eight low-lying levels of Sm atom were measured by using pulsed laser-Boxcar technique in atomic beam.

  15. Lithographed Superconducting Resonator Development for Next-Generation Frequency Multiplexing Readout of Transition-Edge Sensors

    Science.gov (United States)

    Faramarzi, F.; De Haan, T.; Kusaka, A.; Lee, A.; Neuhauser, B.; Plambeck, R.; Raum, C.; Suzuki, A.; Westbrook, B.

    2018-03-01

    Ground-based cosmic microwave background (CMB) experiments are undergoing a period of exponential growth. Current experiments are observing with 1000-10,000 detectors, and the next-generation experiment (CMB stage 4) is proposing to deploy approximately 500,000 detectors. This order of magnitude increase in detector count will require a new approach for readout electronics. We have developed superconducting resonators for next-generation frequency-domain multiplexing (fMUX) readout architecture. Our goal is to reduce the physical size of resonators, such that resonators and detectors can eventually be integrated on a single wafer. To reduce the size of these resonators, we have designed spiral inductors and interdigitated capacitors that resonate around 10-100 MHz, an order of magnitude higher frequency compared to current fMUX readout systems. The higher frequency leads to a wider bandwidth and would enable higher multiplexing factor than the current ˜ 50 detectors per readout channel. We will report on the simulation, fabrication method, characterization technique, and measurement of quality factor of these resonators.

  16. Nuclear magnetic resonance and the question of 5F electron localization in the actinides

    International Nuclear Information System (INIS)

    Fradin, F.Y.

    1976-01-01

    Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons

  17. Mandatory Integration Measures and Differential Inclusion. The Italian Case

    NARCIS (Netherlands)

    Cuttitta, P.

    2016-01-01

    Since 2012 migrants arriving regularly in Italy must sign an integration agreement and declare their agreement with a ‘Charter of the values’. Insufficient integration (measured through a point-based system) results in deportation. While the point-based system discriminates against the poor, the

  18. Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

    Science.gov (United States)

    Dyverfeldt, Petter; Hope, Michael D; Tseng, Elaine E; Saloner, David

    2013-01-01

    The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE. The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography. The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91). Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis. Copyright © 2013 American

  19. The relationship between functional magnetic resonance imaging activation, diffusion tensor imaging, and training effects.

    Science.gov (United States)

    Farrar, Danielle; Budson, Andrew E

    2017-04-01

    While the relationship between diffusion tensor imaging (DTI) measurements and training effects is explored by Voelker et al. (this issue), a cursory discussion of functional magnetic resonance imaging (fMRI) measurements categorizes increased activation with findings of greater white matter integrity. Evidence of the relationship between fMRI activation and white matter integrity is conflicting, as is the relationship between fMRI activation and training effects. An examination of the changes in fMRI activation in response to training is helpful, but the relationship between DTI and fMRI activation, particularly in the context of white matter changes, must be examined further before general conclusions can be drawn.

  20. 238U (n,f) measurements below 30 keV

    International Nuclear Information System (INIS)

    Slovacek, R.E.; Cramer, D.S.; Bean, E.B.; Hockenbury, R.W.; Valentine, J.R.; Block, R.C.

    1975-01-01

    The 238 U (n,f) cross section has been measured from 3 eV to about 30 keV with the lead slowing down spectrometer at the RPI Linac. Four fission ionization chambers containing a total of about 0.8 gm of 238 U (4.1 ppm 235 U) were used for the measurements. The fission widths of the 6.67, 20.9, and the 36.8 eV resonances were measured as (10 +- 1), (58 +- 9), and (12 +- 2) nanoelectron-volts respectively. The fission cross section integrated over the two subthreshold groups at 720 and 1210 eV and the average fission cross section from 10 to 30 keV are in agreement with a previous time of flight measurement. The fission width at 6.67 eV is 20 times smaller than an upper limit set by the only reported measurement in this energy region; the fission widths obtained in the present investigation are consistent with the (30 +- 50) nanoelectronvolt average width previously obtained for the resonances between 37 and 327 eV in a time of flight measurement using a nuclear device. From the measured fission widths, the 238 U thermal fission cross section was determined to be 2.7 +- 0.3 μ barns. The resonance fission integral was also obtained from the data as 1.33 +- 0.15 mbarns for 238 U. (4 figures, 4 tables) (U.S.)

  1. The Physics of Superconducting Microwave Resonators

    Science.gov (United States)

    Gao, Jiansong

    Over the past decade, low temperature detectors have brought astronomers revolutionary new observational capabilities and led to many great discoveries. Although a single low temperature detector has very impressive sensitivity, a large detector array would be much more powerful and are highly demanded for the study of more difficult and fundamental problems in astronomy. However, current detector technologies, such as transition edge sensors and superconducting tunnel junction detectors, are difficult to integrate into a large array. The microwave kinetic inductance detector (MKID) is a promising new detector technology invented at Caltech and JPL which provides both high sensitivity and an easy solution to the detector integration. It senses the change in the surface impedance of a superconductor as incoming photons break Cooper pairs, by using high-Q superconducting microwave resonators capacitively coupled to a common feedline. This architecture allows thousands of detectors to be easily integrated through passive frequency domain multiplexing. In this thesis, we explore the rich and interesting physics behind these superconducting microwave resonators. The first part of the thesis discusses the surface impedance of a superconductor, the kinetic inductance of a superconducting coplanar waveguide, and the circuit response of a resonator. These topics are related with the responsivity of MKIDs. The second part presents the study of the excess frequency noise that is universally observed in these resonators. The properties of the excess noise, including power, temperature, material, and geometry dependence, have been quantified. The noise source has been identified to be the two-level systems in the dielectric material on the surface of the resonator. A semi-empirical noise model has been developed to explain the power and geometry dependence of the noise, which is useful to predict the noise for a specified resonator geometry. The detailed physical noise

  2. Measurements of Pulmonary Artery Size for Assessment of Pulmonary Hypertension by Cardiovascular Magnetic Resonance and Clinical Application

    Directory of Open Access Journals (Sweden)

    Fan YANG

    2017-02-01

    Full Text Available Background and objective Pulmonary hypertension (PH often leads to dilatation of main pulmonary artery (MPA. MPA measurements can be used to predict PH. This aim of this study is to investigate power of MPA vessel indices, which are acquired from cardiovascular magnetic resonance, to evaluate PH. Methods Cardiovascular-magnetic-resonance-determined parameters of MPA were acquired and calculated in 83 PH patients, whose diagnosis were confirmed with right heart catheterization and 49 healthy volunteers; these parameters included MPA diameter (DPA, ratio of DPA and ascending aorta diameter (DPA/DAo, max mean diameter (MDmax, min mean diameter (MDmin, fraction transverse diameter (fTD, fraction longitudinal diameter (fLD, and distensibility. Results Compared with control group, DPA, DPA/DAo, MDmax, and MDmin were significantly higher in patients with PH (P28.4 mm, and MDmax>32.4 mm (area under the curve, AUC=0.979, 0.981 showed best performance in predicting PH, yielding highest specificity at 100%. Conclusion Noninvasive cardiovascular-magnetic-resonance-derived MPA measurements provide excellent and practical reference in clinical settings for detecting PH.

  3. Bioluminescence resonance energy transfer system for measuring dynamic protein-protein interactions in bacteria.

    Science.gov (United States)

    Cui, Boyu; Wang, Yao; Song, Yunhong; Wang, Tietao; Li, Changfu; Wei, Yahong; Luo, Zhao-Qing; Shen, Xihui

    2014-05-20

    Protein-protein interactions are important for virtually every biological process, and a number of elegant approaches have been designed to detect and evaluate such interactions. However, few of these methods allow the detection of dynamic and real-time protein-protein interactions in bacteria. Here we describe a bioluminescence resonance energy transfer (BRET) system based on the bacterial luciferase LuxAB. We found that enhanced yellow fluorescent protein (eYFP) accepts the emission from LuxAB and emits yellow fluorescence. Importantly, BRET occurred when LuxAB and eYFP were fused, respectively, to the interacting protein pair FlgM and FliA. Furthermore, we observed sirolimus (i.e., rapamycin)-inducible interactions between FRB and FKBP12 and a dose-dependent abolishment of such interactions by FK506, the ligand of FKBP12. Using this system, we showed that osmotic stress or low pH efficiently induced multimerization of the regulatory protein OmpR and that the multimerization induced by low pH can be reversed by a neutralizing agent, further indicating the usefulness of this system in the measurement of dynamic interactions. This method can be adapted to analyze dynamic protein-protein interactions and the importance of such interactions in bacterial processes such as development and pathogenicity. Real-time measurement of protein-protein interactions in prokaryotes is highly desirable for determining the roles of protein complex in the development or virulence of bacteria, but methods that allow such measurement are not available. Here we describe the development of a bioluminescence resonance energy transfer (BRET) technology that meets this need. The use of endogenous excitation light in this strategy circumvents the requirement for the sophisticated instrument demanded by standard fluorescence resonance energy transfer (FRET). Furthermore, because the LuxAB substrate decanal is membrane permeable, the assay can be performed without lysing the bacterial cells

  4. Simulation of electron spin resonance spectroscopy in diverse environments: An integrated approach

    Science.gov (United States)

    Zerbetto, Mirco; Polimeno, Antonino; Barone, Vincenzo

    2009-12-01

    We discuss in this work a new software tool, named E-SpiReS (Electron Spin Resonance Simulations), aimed at the interpretation of dynamical properties of molecules in fluids from electron spin resonance (ESR) measurements. The code implements an integrated computational approach (ICA) for the calculation of relevant molecular properties that are needed in order to obtain spectral lines. The protocol encompasses information from atomistic level (quantum mechanical) to coarse grained level (hydrodynamical), and evaluates ESR spectra for rigid or flexible single or multi-labeled paramagnetic molecules in isotropic and ordered phases, based on a numerical solution of a stochastic Liouville equation. E-SpiReS automatically interfaces all the computational methodologies scheduled in the ICA in a way completely transparent for the user, who controls the whole calculation flow via a graphical interface. Parallelized algorithms are employed in order to allow running on calculation clusters, and a web applet Java has been developed with which it is possible to work from any operating system, avoiding the problems of recompilation. E-SpiReS has been used in the study of a number of different systems and two relevant cases are reported to underline the promising applicability of the ICA to complex systems and the importance of similar software tools in handling a laborious protocol. Program summaryProgram title: E-SpiReS Catalogue identifier: AEEM_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEM_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPL v2.0 No. of lines in distributed program, including test data, etc.: 311 761 No. of bytes in distributed program, including test data, etc.: 10 039 531 Distribution format: tar.gz Programming language: C (core programs) and Java (graphical interface) Computer: PC and Macintosh Operating system: Unix and Windows Has the code been vectorized or

  5. Simultaneous resonant x-ray diffraction measurement of polarization inversion and lattice strain in polycrystalline ferroelectrics

    DEFF Research Database (Denmark)

    Gorfman, S.; Simons, Hugh; Iamsasri, T.

    2016-01-01

    and strain in ferroelectrics is an ongoing challenge that so far has obscured its fundamental behaviour. By utilizing small intensity differences between Friedel pairs due to resonant scattering, we demonstrate a time-resolved X-ray diffraction technique for directly and simultaneously measuring both lattice...

  6. Relative measurement of the fluxes of thermal, resonant and rapid neutrons in reactor G1

    International Nuclear Information System (INIS)

    Carle, R.; Mazancourt, T. de

    1957-01-01

    We sought to determine the behavior of the thermal, resonant and rapid neutron fluxes in the multiplier-reflector transition region, in the two principal directions of the system. We have also measured the variation of these different fluxes in the body of the multiplier medium in a canal filled with graphite and in an empty canal. The results are given in the form of curves representing: - the variation of the ratio of the thermal flux to the rapid flux in axial and radial transitions - the behavior of the thermal and resonant fluxes and the variation of their ratio in the same regions. (author) [fr

  7. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Robson, E-mail: robmacedo@yahoo.com [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Fernandes, Juliano Lara [Universidade Estadual de Campinas, Campinas, SP (Brazil); Andrade, Solange Souza; Rochitte, Carlos Eduardo [Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho [Universidade Potiguar, Natal, RN (Brazil); Coelho, Otávio Rizzi [Universidade Estadual de Campinas, Campinas, SP (Brazil); Diniz, Rosiane Viana Zuza [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil)

    2013-07-15

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.

  8. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    International Nuclear Information System (INIS)

    Macedo, Robson; Fernandes, Juliano Lara; Andrade, Solange Souza; Rochitte, Carlos Eduardo; Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti; Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho; Coelho, Otávio Rizzi; Diniz, Rosiane Viana Zuza

    2013-01-01

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age

  9. Bayesian Integrated Data Analysis of Fast-Ion Measurements by Velocity-Space Tomography

    DEFF Research Database (Denmark)

    Salewski, M.; Nocente, M.; Jacobsen, A.S.

    2018-01-01

    Bayesian integrated data analysis combines measurements from different diagnostics to jointly measure plasma parameters of interest such as temperatures, densities, and drift velocities. Integrated data analysis of fast-ion measurements has long been hampered by the complexity of the strongly non...... framework. The implementation for different types of diagnostics as well as the uncertainties are discussed, and we highlight the importance of integrated data analysis of all available detectors....

  10. Integrated photonics using colloidal quantum dots

    Science.gov (United States)

    Menon, Vinod M.; Husaini, Saima; Okoye, Nicky; Valappil, Nikesh V.

    2009-11-01

    Integrated photonic devices were realized using colloidal quantum dot composites such as flexible microcavity laser, microdisk emitters and integrated active-passive waveguides. The microcavity laser structure was realized using spin coating and consisted of an all-polymer distributed Bragg reflector with a poly-vinyl carbazole cavity layer embedded with InGaP/ZnS colloidal quantum dots. These microcavities can be peeled off the substrate yielding a flexible structure that can conform to any shape and whose emission spectra can be mechanically tuned. Planar photonic devices consisting of vertically coupled microring resonators, microdisk emitters, active-passive integrated waveguide structures and coupled active microdisk resonators were realized using soft lithography, photo-lithography, and electron beam lithography, respectively. The gain medium in all these devices was a composite consisting of quantum dots embedded in SU8 matrix. Finally, the effect of the host matrix on the optical properties of the quantum dots using results of steady-state and time-resolved luminescence measurements was determined. In addition to their specific functionalities, these novel device demonstrations and their development present a low-cost alternative to the traditional photonic device fabrication techniques.

  11. In search of an integrative measure of functioning.

    Science.gov (United States)

    Madden, Rosamond H; Glozier, Nick; Fortune, Nicola; Dyson, Maree; Gilroy, John; Bundy, Anita; Llewellyn, Gwynnyth; Salvador-Carulla, Luis; Lukersmith, Sue; Mpofu, Elias; Madden, Richard

    2015-05-26

    International trends towards people-centred, integrative care and support require any measurement of functioning and disability to meet multiple aims. The information requirements of two major Australian programs for disability and rehabilitation are outlined, and the findings of two searches for suitable measures of functioning and disability are analysed. Over 30 current measures of functioning were evaluated in each search. Neither search found a generic measure of functioning suitable for these multibillion dollar programs, relevant to a wide range of people with a variety of health conditions and functioning experiences, and capable of indicating support needs, associated costs, progress and outcomes. This unsuccessful outcome has implications internationally for policy-relevant information for disability, rehabilitation and related programs. The paper outlines the features of an Integrative Measure of Functioning (IMF) based on the concepts of functioning and environmental factors in the International Classification of Functioning, Disability and Health (ICF). An IMF would be applicable across a variety of health conditions, settings and purposes, ranging from individual assessment to public health. An IMF could deliver person-centred, policy-relevant information for a range of programs, promoting harmonised language and measurement and supporting international trends in human services and public health.

  12. Molecular resonances in 28SI + 28Si - Wobbling motions observed by angular correlation measurements

    International Nuclear Information System (INIS)

    Uegaki, E.; Abe, Y.

    2014-01-01

    High-spin resonances observed in 28 Si+ 28 Si collisions are studied with a dinuclear molecular model. At high spins, a stable dinuclear configuration of the oblate-oblate system ( 28 Si+ 28 Si) is found to be an equator-equator (E-E) touching one. Normal modes have been investigated around the equilibrium, which are expected to be an origin of a large number of the resonances observed. Analyses of physical quantities are made and compared with the recent experimental data measured at Strasbourg. Since the E-E configuration is slightly triaxial, rotations of the total system induce mixing of K quantum numbers, called wobbling motion, which clearly explains the particle-γ angular correlations observed as well as the misalignments observed in the angular distributions, in a simple and natural way. Furthermore, predictions are given for the angular correlations of the wobbling excited states. The importance of the angular correlation measurements is stressed, which provide identification of the dinuclear configurations by spin orientations of the constituent nuclei 28 Si. (authors)

  13. Nitric oxide concentration measurements in atmospheric pressure flames using electronic-resonance-enhanced coherent anti-Stokes Raman scattering

    Science.gov (United States)

    Chai, N.; Kulatilaka, W. D.; Naik, S. V.; Laurendeau, N. M.; Lucht, R. P.; Kuehner, J. P.; Roy, S.; Katta, V. R.; Gord, J. R.

    2007-06-01

    We report the application of electronic-resonance-enhanced coherent anti-Stokes Raman scattering (ERE-CARS) for measurements of nitric oxide concentration ([NO]) in three different atmospheric pressure flames. Visible pump (532 nm) and Stokes (591 nm) beams are used to probe the Q-branch of the Raman transition. A significant resonance enhancement is obtained by tuning an ultraviolet probe beam (236 nm) into resonance with specific rotational transitions in the (v’=0, v”=1) vibrational band of the A2Σ+-X2Π electronic system of NO. ERE-CARS spectra are recorded at various heights within a hydrogen-air flame producing relatively low concentrations of NO over a Hencken burner. Good agreement is obtained between NO ERE-CARS measurements and the results of flame computations using UNICORN, a two-dimensional flame code. Excellent agreement between measured and calculated NO spectra is also obtained when using a modified version of the Sandia CARSFT code for heavily sooting acetylene-air flames (φ=0.8 to φ=1.6) on the same Hencken burner. Finally, NO concentration profiles are measured using ERE-CARS in a laminar, counter-flow, non-premixed hydrogen-air flame. Spectral scans are recorded by probing the Q1 (9.5), Q1 (13.5) and Q1 (17.5) Raman transitions. The measured shape of the [NO] profile is in good agreement with that predicted using the OPPDIF code, even without correcting for collisional effects. These comparisons between [NO] measurements and predictions establish the utility of ERE-CARS for detection of NO in flames with large temperature and concentration gradients as well as in sooting environments.

  14. RESONANCE TRAPPING IN PROTOPLANETARY DISKS. I. COPLANAR SYSTEMS

    International Nuclear Information System (INIS)

    Lee, Aaron T.; Thommes, Edward W.; Rasio, Frederic A.

    2009-01-01

    Mean-motion resonances (MMRs) are likely to play an important role both during and after the lifetime of a protostellar gas disk. We study the dynamical evolution and stability of planetary systems containing two giant planets on circular orbits near a 2:1 resonance and closer. We find that by having the outer planet migrate inward, the two planets can capture into either the 2:1, 5:3, or 3:2 MMR. We use direct numerical integrations of ∼1000 systems in which the planets are initially locked into one of these resonances and allowed to evolve for up to ∼10 7 yr. We find that the final eccentricity distribution in systems which ultimately become unstable gives a good fit to observed exoplanets. Next, we integrate ∼500 two-planet systems in which the outer planet is driven to continuously migrate inward, resonantly capturing the inner planet; the systems are evolved until either instability sets in or the planets reach the star. We find that although the 5:3 resonance rapidly becomes unstable under migration, the 2:1 and 3:2 are very stable. Thus the lack of observed exoplanets in resonances closer than 2:1, if it continues to hold up, may be a primordial signature of the planet formation process.

  15. Photoproduction of η -mesons on protons in the resonance region: The background problem and the third S11-resonance

    International Nuclear Information System (INIS)

    Tryasuchev, V.A.

    2004-01-01

    We have constructed an isobar model for the η -photoproduction on the proton in the energy region up to the photon lab energy K 0 = 3 GeV. The database involved into the fitting procedure includes precise results for the cross-section and for the T-asymmetry of the process γp→ηp near threshold obtained at MAMI and ELSA as well as recent results for the Σ -asymmetry and for the angular distribution measured at higher energies in Grenoble and also more recent measurements performed at JLab for the photon energies up to 2 GeV. The model includes twelve nucleon resonances: S 11 (1535), S 11 (1650), S 11 (1825), P 11 (1440), P 13 (1720), D 13 (1520), D 15 (1675), F 15 (1680), F 17 (1990), G 17 (2190), G 19 (2250), H 19 (2220), and the background consisting of the nucleon pole term and the vector meson exchange in the t-channel. To explain the observed energy dependence of the integrated cross-section, two s-wave resonances, S 11 (1650) and S 11 (1825), have to be taken into account along with the dominating S 11 (1535). The integrated cross-section as well as the angular distribution and Σ -asymmetry predicted by the model are in good agreement with the data. Above the photon energy K 0 =2 GeV, the calculated cross-section exhibits an appreciable dependence on the ρ- and ω -meson contribution, whose coupling with nucleons is not well defined. Several versions of extending the model to higher energies are considered. (orig.)

  16. On Frequency Combs in Monolithic Resonators

    Directory of Open Access Journals (Sweden)

    Savchenkov A. A.

    2016-06-01

    Full Text Available Optical frequency combs have become indispensable in astronomical measurements, biological fingerprinting, optical metrology, and radio frequency photonic signal generation. Recently demonstrated microring resonator-based Kerr frequency combs point the way towards chip scale optical frequency comb generator retaining major properties of the lab scale devices. This technique is promising for integrated miniature radiofrequency and microwave sources, atomic clocks, optical references and femtosecond pulse generators. Here we present Kerr frequency comb development in a historical perspective emphasizing its similarities and differences with other physical phenomena. We elucidate fundamental principles and describe practical implementations of Kerr comb oscillators, highlighting associated solved and unsolved problems.

  17. Integration of fiber-coupled high-Q SiNx microdisks with atom chips

    International Nuclear Information System (INIS)

    Barclay, Paul E.; Srinivasan, Kartik; Painter, Oskar; Lev, Benjamin; Mabuchi, Hideo

    2006-01-01

    Micron scale silicon nitride (SiN x ) microdisk optical resonators are demonstrated with Q=3.6x10 6 and an effective mode volume of 15(λ/n) 3 at near-visible wavelengths. A hydrofluoric acid wet etch provides sensitive tuning of the microdisk resonances, and robust mounting of a fiber taper provides efficient fiber optic coupling to the microdisks while allowing unfettered optical access for laser cooling and trapping of atoms. Measurements indicate that cesium adsorption on the SiN x surfaces significantly red detunes the microdisk resonances. Parallel integration of multiple (10) microdisks with a single fiber taper is also demonstrated

  18. A New Look at an Old Activity: Resonance Tubes Used to Teach Resonance

    Science.gov (United States)

    Nelson, Jim; Nelson, Jane

    2017-01-01

    There are several variations of resonance laboratory activities used to determine the speed of sound. This is "not" one of them. This activity uses the resonance tube idea to teach "resonance," not to verify the speed of sound. Prior to this activity, the speed of sound has already been measured using computer sound-sensors and…

  19. Measuring fragmentation in dissociative identity disorder: the integration measure and relationship to switching and time in therapy

    Directory of Open Access Journals (Sweden)

    Margaret Rose Barlow

    2014-01-01

    Full Text Available Background: Some people with dissociative identity disorder (DID have very little communication or awareness among the parts of their identity, while others experience a great deal of cooperation among alternate identities. Previous research on this topic has been sparse. Currently, there is no empirical measure of integration versus fragmentation in a person with DID. In this study, we report the development of such a measure. Objective: The goal of this study was to pilot the integration measure (IM and to address its psychometric properties and relationships to other measures. The IM is the first standardized measure of integration in DID. Method: Eleven women with DID participated in an experiment that included a variety of tasks. They filled out questionnaires about trauma and dissociation as well as the IM. They also provided verbal results about switching among alternate identities during the study sessions. Results: Participants switched among identities an average of 5.8 times during the first session, and switching was highly correlated with trauma. Integration was related to switching, though this relationship may be non-linear. Integration was not related to time in psychotherapy. Conclusions: The IM provides a useful beginning to quantify and study integration and fragmentation in DID. Directions for future research are also discussed, including expanding the IM from this pilot. The IM may be useful in treatment settings to assess progress or change over time.

  20. Penetration depth measurement of a 6 MeV electron beam in water by magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    B. E. Hammer

    2011-11-01

    Full Text Available We demonstrate magnetic resonance imaging (MRI visualization of a 6 MeV electron beam in ferrous-doped water; a 25 mm penetration depth was measured. Time domain nuclear magnetic resonance was used to investigate the effect of generated free radicals on the free induction decay (FID in nondoped water; no apparent effects to the FID were observed. We show that MRI visualization of charged particle beams used in medical applications will require exogenous agents to provide contrast enhancement.

  1. Measurement of the average lifetime of the beauty hadrons on the Z resonance

    International Nuclear Information System (INIS)

    Fernandez, D.

    1997-01-01

    From a fit to the impact parameter distribution of inclusive electron and muons from semileptonic b decay, the average lifetime of beauty hadrons produced in e + e - collisions on the Z resonance was measured to be: T B =1.543+-0.016(est)+-0.024(sis)ps Combining this measurement with the earlier semileptonic braching ratio B gamma(B→y ν Χ) the Cabbibo-Kowayashi-Maskawa matrix element vertical barV cb vertical bar is determined to be: vertical barV cb vertical bar=(38.8+-0.8 (exp)+- ''3.0 2 .6 (teor))x10 -3

  2. Seamless variation of isometric and anisometric dynamical integrity measures in basins's erosion

    Science.gov (United States)

    Belardinelli, P.; Lenci, S.; Rega, G.

    2018-03-01

    Anisometric integrity measures defined as improvement and generalization of two existing measures (LIM, local integrity measure, and IF, integrity factor) of the extent and compactness of basins of attraction are introduced. Non-equidistant measures make it possible to account for inhomogeneous sensitivities of the state space variables to perturbations, thus permitting a more confident and targeted identification of the safe regions. All four measures are used for a global dynamics analysis of the twin-well Duffing oscillator, which is performed by considering a nearly continuous variation of a governing control parameter, thanks to the use of parallel computation allowing reasonable CPU time. This improves literature results based on finite (and commonly large) variations of the parameter, due to computational constraints. The seamless evolution of key integrity measures highlights the fine aspects of the erosion of the safe domain with respect to the increasing forcing amplitude.

  3. Actinides integral measurements on FCA assemblies

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Okajima, Shigeaki

    1984-01-01

    Actinide integral measurements were performed on eight assemblies of FCA where neutron energy spectra were shifted systematically from soft to hard in order to evaluate and modify the nuclear cross section data of major actinides. Experimental values on actinide fission rates and sample reactivity worths are compared with the calculated values using JENDL-2 and ENDF/B-V (or IV) data sets. (author)

  4. Asymmetric resonance frequency analysis of in-plane electrothermal silicon cantilevers for nanoparticle sensors

    Science.gov (United States)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Marks, Markus; Suryo Wasisto, Hutomo; Peiner, Erwin

    2016-10-01

    The asymmetric resonance frequency analysis of silicon cantilevers for a low-cost wearable airborne nanoparticle detector (Cantor) is described in this paper. The cantilevers, which are operated in the fundamental in-plane resonance mode, are used as a mass-sensitive microbalance. They are manufactured out of bulk silicon, containing a full piezoresistive Wheatstone bridge and an integrated thermal heater for reading the measurement output signal and stimulating the in-plane excitation, respectively. To optimize the sensor performance, cantilevers with different cantilever geometries are designed, fabricated and characterized. Besides the resonance frequency, the quality factor (Q) of the resonance curve has a high influence concerning the sensor sensitivity. Because of an asymmetric resonance behaviour, a novel fitting function and method to extract the Q is created, different from that of the simple harmonic oscillator (SHO). For testing the sensor in a long-term frequency analysis, a phase- locked loop (PLL) circuit is employed, yielding a frequency stability of up to 0.753 Hz at an Allan variance of 3.77 × 10-6. This proposed asymmetric resonance frequency analysis method is expected to be further used in the process development of the next-generation Cantor.

  5. Asymmetric resonance frequency analysis of in-plane electrothermal silicon cantilevers for nanoparticle sensors

    International Nuclear Information System (INIS)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Marks, Markus; Wasisto, Hutomo Suryo; Peiner, Erwin

    2016-01-01

    The asymmetric resonance frequency analysis of silicon cantilevers for a low-cost wearable airborne nanoparticle detector (Cantor) is described in this paper. The cantilevers, which are operated in the fundamental in-plane resonance mode, are used as a mass-sensitive microbalance. They are manufactured out of bulk silicon, containing a full piezoresistive Wheatstone bridge and an integrated thermal heater for reading the measurement output signal and stimulating the in-plane excitation, respectively. To optimize the sensor performance, cantilevers with different cantilever geometries are designed, fabricated and characterized. Besides the resonance frequency, the quality factor ( Q ) of the resonance curve has a high influence concerning the sensor sensitivity. Because of an asymmetric resonance behaviour, a novel fitting function and method to extract the Q is created, different from that of the simple harmonic oscillator (SHO). For testing the sensor in a long-term frequency analysis, a phase- locked loop (PLL) circuit is employed, yielding a frequency stability of up to 0.753 Hz at an Allan variance of 3.77 × 10 -6 . This proposed asymmetric resonance frequency analysis method is expected to be further used in the process development of the next-generation Cantor. (paper)

  6. Resonant dynamics of gravitationally bound pair of binaries: the case of 1:1 resonance

    Science.gov (United States)

    Breiter, Slawomir; Vokrouhlický, David

    2018-04-01

    The work presents a study of the 1:1 resonance case in a hierarchical quadruple stellar system of the 2+2 type. The resonance appears if orbital periods of both binaries are approximately equal. It is assumed that both periods are significantly shorter than the period of principal orbit of one binary with respect to the other. In these circumstances, the problem can be treated as three independent Kepler problems perturbed by mutual gravitational interactions. By means of canonical perturbation methods, the planar problem is reduced to a secular system with 1 degree of freedom involving a resonance angle (the difference of mean longitudes of the binaries) and its conjugate momentum (involving the ratio of orbital period in one binary to the period of principal orbit). The resonant model is supplemented with short periodic perturbations expressions, and verified by the comparison with numerical integration of the original equations of motion. Estimates of the binaries periods variations indicate that the effect is rather weak, but possibly detectible if it occurs in a moderately compact system. However, the analysis of resonance capture scenarios implies that the 1:1 resonance should be exceptional amongst the 2+2 quadruples.

  7. Experiences in integrated leak rate measurements

    International Nuclear Information System (INIS)

    Shirk, R.E.

    1982-01-01

    During a hypothetical design basis accident for nuclear power plants, the reactor containment system is relied upon to maintain radioactive exposure limits below acceptable limits. Integrated leak rate testing is a means of verifying that the leakage of radioactivity material from the reactor containment will be below allowable limits. Leakage rate computations are based on the ideal gas law. The absolute method of leakage rate testing utilizing mass point method of data analysis is recommended. Integrated leak rate testing data is obtained from pressure, drybulb temperature, dewpoint temperature, and flow measuring systems. Test data does not support the usual leakage (flow) - pressure square root relationship. The major source of potential leakage from the reactor containment is reactor containment isolation valves

  8. Resonance structure of 32S+n from measurements of neutron total and capture cross sections

    International Nuclear Information System (INIS)

    Halperin, J.; Johnson, C.H.; Winters, R.R.; Macklin, R.L.

    1980-01-01

    Neutron total and capture cross sections of 32 S have been measured up to 1100 keV neutron energy [E/sub exc/( 33 S) =9700 keV]. Spin and parity assignments have been made for 28 of the 64 resonances found in this region. Values of total radiation widths, reduced neutron widths, level spacings, and neutron strength functions have been evaluated for s/sub 1/2/, p/sub 1/2/, p/sub 3/2/, and d/sub 5/2/ levels. Single particle contributions using the valency model account for a significant portion of the total radiation width only for the p/sub 1/2/-wave resonances. A significant number of resonances can be identified with reported levels excited in 32 S(d,p) and 29 Si(α,n) reactions. A calculation of the Maxwellian average cross section appropriate to stellar interiors indicates an average capture cross section at 30 keV, sigma-bar approx. = 4.2(2) mb, a result that is relatively insensitive to the assumed stellar temperature. Direct (potential) capture and the s-wave resonance capture contributions to the thermal capture cross section do not fully account for the reported thermal cross section (530 +- 40 mb) and a bound state is invoked to account for the discrepancy

  9. Flow-excited acoustic resonance excitation mechanism, design guidelines, and counter measures

    International Nuclear Information System (INIS)

    Ziada, Samir; Lafon, Philippe

    2014-01-01

    The excitation mechanism of acoustic resonances has long been recognized, but the industry continues to be plagued by its undesirable consequences, manifested in severe vibration and noise problems in a wide range of industrial applications. This paper focuses on the nature of the excitation mechanism of acoustic resonances in piping systems containing impinging shear flows, such as flow over shallow and deep cavities. Since this feedback mechanism is caused by the coupling between acoustic resonators and shear flow instabilities, attention is focused first on the nature of various types of acoustic resonance modes and then on the aero-acoustic sound sources, which result from the interaction of the inherently unstable shear flow with the sound field generated by the resonant acoustic modes. Various flow-sound interaction patterns are discussed, in which the resonant sound field can be predominantly parallel or normal to the mean flow direction and the acoustic wavelength can be an order of magnitude longer than the length scale of the separated shear flow or as short as the cavity length scale. Since the state of knowledge in this field has been recently reviewed by Tonon et al. (2011, 'Aero-acoustics of Pipe Systems With Closed Branches', Int. J. Aeroacoust., 10(2), pp. 201-276), this article focuses on the more practical aspects of the phenomenon, including various flow sound interaction patterns and the resulting aero-acoustic sources, which are relevant to industrial applications. A general design guide proposal and practical means to alleviate the excitation mechanism are also presented. These are demonstrated by two examples of recent industrial case histories dealing with acoustic fatigue failure of the steam dryer in a boiling water reactor (BWR) due to acoustic resonance in the main steam piping and acoustic resonances in the roll posts of the Short Take-Off and Vertical Lift Joint Strike Fighter (JSF). (authors)

  10. Resting state functional connectivity magnetic resonance imaging integrated with intraoperative neuronavigation for functional mapping after aborted awake craniotomy

    Science.gov (United States)

    Batra, Prag; Bandt, S. Kathleen; Leuthardt, Eric C.

    2016-01-01

    Background: Awake craniotomy is currently the gold standard for aggressive tumor resections in eloquent cortex. However, a significant subset of patients is unable to tolerate this procedure, particularly the very young or old or those with psychiatric comorbidities, cardiopulmonary comorbidities, or obesity, among other conditions. In these cases, typical alternative procedures include biopsy alone or subtotal resection, both of which are associated with diminished surgical outcomes. Case Description: Here, we report the successful use of a preoperatively obtained resting state functional connectivity magnetic resonance imaging (MRI) integrated with intraoperative neuronavigation software in order to perform functional cortical mapping in the setting of an aborted awake craniotomy due to loss of airway. Conclusion: Resting state functional connectivity MRI integrated with intraoperative neuronavigation software can provide an alternative option for functional cortical mapping in the setting of an aborted awake craniotomy. PMID:26958419

  11. Measurement of renal blood flow by phase-contrast magnetic resonance imaging during septic acute kidney injury: a pilot investigation.

    Science.gov (United States)

    Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo

    2012-06-01

    In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in

  12. Intercomparison of derived integral data from evaluated data libraries of the actinides

    International Nuclear Information System (INIS)

    Paviotti Corcuera, R.

    1988-12-01

    Resonance integrals and fission spectrum averaged cross-sections are calculated for the actinides from all recent major evaluated libraries. Whenever possible the results are compared against measurements. It is found that the experimental data are scarce and that there exist considerable differences between experimentally measured data and those derived from the evaluated libraries. (author). 93 refs and tabs

  13. Integration of Error Compensation of Coordinate Measuring Machines into Feature Measurement: Part I—Model Development

    Science.gov (United States)

    Calvo, Roque; D’Amato, Roberto; Gómez, Emilio; Domingo, Rosario

    2016-01-01

    The development of an error compensation model for coordinate measuring machines (CMMs) and its integration into feature measurement is presented. CMMs are widespread and dependable instruments in industry and laboratories for dimensional measurement. From the tip probe sensor to the machine display, there is a complex transformation of probed point coordinates through the geometrical feature model that makes the assessment of accuracy and uncertainty measurement results difficult. Therefore, error compensation is not standardized, conversely to other simpler instruments. Detailed coordinate error compensation models are generally based on CMM as a rigid-body and it requires a detailed mapping of the CMM’s behavior. In this paper a new model type of error compensation is proposed. It evaluates the error from the vectorial composition of length error by axis and its integration into the geometrical measurement model. The non-explained variability by the model is incorporated into the uncertainty budget. Model parameters are analyzed and linked to the geometrical errors and uncertainty of CMM response. Next, the outstanding measurement models of flatness, angle, and roundness are developed. The proposed models are useful for measurement improvement with easy integration into CMM signal processing, in particular in industrial environments where built-in solutions are sought. A battery of implementation tests are presented in Part II, where the experimental endorsement of the model is included. PMID:27690052

  14. Integration of Error Compensation of Coordinate Measuring Machines into Feature Measurement: Part I—Model Development

    Directory of Open Access Journals (Sweden)

    Roque Calvo

    2016-09-01

    Full Text Available The development of an error compensation model for coordinate measuring machines (CMMs and its integration into feature measurement is presented. CMMs are widespread and dependable instruments in industry and laboratories for dimensional measurement. From the tip probe sensor to the machine display, there is a complex transformation of probed point coordinates through the geometrical feature model that makes the assessment of accuracy and uncertainty measurement results difficult. Therefore, error compensation is not standardized, conversely to other simpler instruments. Detailed coordinate error compensation models are generally based on CMM as a rigid-body and it requires a detailed mapping of the CMM’s behavior. In this paper a new model type of error compensation is proposed. It evaluates the error from the vectorial composition of length error by axis and its integration into the geometrical measurement model. The non-explained variability by the model is incorporated into the uncertainty budget. Model parameters are analyzed and linked to the geometrical errors and uncertainty of CMM response. Next, the outstanding measurement models of flatness, angle, and roundness are developed. The proposed models are useful for measurement improvement with easy integration into CMM signal processing, in particular in industrial environments where built-in solutions are sought. A battery of implementation tests are presented in Part II, where the experimental endorsement of the model is included.

  15. [Exploration of three-dimensional biometric measurement of emmetropic adult eye-ball by using magnetic resonance imaging technology].

    Science.gov (United States)

    Xu, Hai-Ming; Zhou, Yun-Xin; Shi, Ming-Guang

    2008-11-01

    To study biometric measurements of emmetropic adult eyes with magnetic resonance imaging technology (MRI). MRI technology, with super-resolution, hyper-speed imaging and the integration of the thin-scanning layer, is applied to measure the three-dimensional biometric parameters of the eyeball. From January to December, 2003, emmetropic eyes from 31 normal Chinese adults (16 males and 15 females) aged from 18 to 32 years old (23.32 +/- 3.32) were successfully measured to obtain the volume of the eyeball and vitreous cavity; inner dimensions of the eye, including the anterior-posterior, vertical and horizontal diameters. The length of ocular axis was measured by A-echo too. Data was analyzed by SPSS 11.0 statistical software. The volume of the eyeball, anterior chamber, lens and the vitreous cavity is (6.013 +/- 0.449) ml, (0.348 +/- 0.020) ml, (0.183 +/- 0.015) ml, and (5.482 +/- 0.440) ml, respectively. The length of anterior-posterior diameter of the vitreous cavity is (16.008 +/- 0.707) mm. The ocular inner dimensions of horizontal, vertical and anterior-posterior planes were (22.455 +/- 0.983) mm, (23.290 +/- 0.815) mm and (22.619 +/- 0.912) mm, respectively. The length of the ocular axis is (23.10 +/- 0.92) mm (with MRI & Orbscan II) and (23.67 +/- 0.82) mm (with A-echo). The value of the ocular length in emmetropic eye measured with both MRI + Orbscan II and the (A-echo) in the present study is very close to the value of the Bennett-Rabbitts schematic eye (24.09 mm). MRI technology is valuable for obtaining more reliable and precise data in the study of ocular physiology and clinical ophthalmology.

  16. Hadronic Resonances from STAR

    Directory of Open Access Journals (Sweden)

    Wada Masayuki

    2012-11-01

    Full Text Available The results of resonance particle productions (ρ0, ω, K*, ϕ, Σ*, and Λ* measured by the STAR collaboration at RHIC from various colliding systems and energies are presented. Measured mass, width, 〈pT〉, and yield of those resonances are reviewed. No significant mass shifts or width broadening beyond the experiment uncertainties are observed. New measurements of ϕ and ω from leptonic decay channels are presented. The yields from leptonic decay channels are compared with the measurements from hadronic decay channels and the two results are consistent with each other.

  17. Strongly driven electron spins using a Ku band stripline electron paramagnetic resonance resonator

    Science.gov (United States)

    Yap, Yung Szen; Yamamoto, Hiroshi; Tabuchi, Yutaka; Negoro, Makoto; Kagawa, Akinori; Kitagawa, Masahiro

    2013-07-01

    This article details our work to obtain strong excitation for electron paramagnetic resonance (EPR) experiments by improving the resonator's efficiency. The advantages and application of strong excitation are discussed. Two 17 GHz transmission-type, stripline resonators were designed, simulated and fabricated. Scattering parameter measurements were carried out and quality factor were measured to be around 160 and 85. Simulation results of the microwave's magnetic field distribution are also presented. To determine the excitation field at the sample, nutation experiments were carried out and power dependence were measured using two organic samples at room temperature. The highest recorded Rabi frequency was rated at 210 MHz with an input power of about 1 W, which corresponds to a π/2 pulse of about 1.2 ns.

  18. Complete evaluation of 241Am between thermal energy and 15 MeV - Nuclear models used consistency with integral data

    International Nuclear Information System (INIS)

    Fort, E.; Darrouzet, M.; Derrien, H.; Hammer, P.; Martin-Deidier, L.

    1979-01-01

    In this evaluation both integral and microscopic data are considered as reference data. Calculations are performed with SLBW formalism in the resolved resonance region and statistical formalism elsewhere. Neutron penetrabilities are obtained from coupled channel calculations, considering 241 Am as a symmetric rotationnal nucleus. For fission the agreement is excellent between evaluated and integral data and is confirmed by the most recent microscopic measurements. High values for capture cross-sections are supported by integral measurements

  19. Jet activity as a probe of high-mass resonance production

    Energy Technology Data Exchange (ETDEWEB)

    Harland-Lang, L.A. [University College London, Department of Physics and Astronomy, London (United Kingdom); Khoze, V.A. [Durham University, Institute for Particle Physics Phenomenology, Durham (United Kingdom); NRC Kurchatov Institute, Petersburg Nuclear Physics Institute, St. Petersburg (Russian Federation); Ryskin, M.G. [NRC Kurchatov Institute, Petersburg Nuclear Physics Institute, St. Petersburg (Russian Federation); Spannowsky, M. [Durham University, Institute for Particle Physics Phenomenology, Durham (United Kingdom)

    2016-11-15

    We explore the method of using the measured jet activity associated with a high-mass resonance state to determine the corresponding production modes. To demonstrate the potential of the approach, we consider the case of a resonance of mass M{sub R} decaying to a diphoton final state. We perform a Monte Carlo study, considering three mass points M{sub R} = 0.75, 1.5, 2.5 TeV, and show that the γγ, WW, gg and light and heavy q anti q initiated cases lead to distinct predictions for the jet multiplicity distributions. As an example, we apply this result to the ATLAS search for resonances in diphoton events, using the 2015 data set of 3.2 fb{sup -1} at √(s) = 13 TeV. Taking the spin-0 selection, we demonstrate that a dominantly gg-initiated signal hypothesis is mildly disfavoured, while the γγ and light quark cases give good descriptions within the limited statistics, and a dominantly WW-initiated hypothesis is found to be in strong tension with the data. We also comment on the b anti b initial state, which can already be constrained by the measured b-jet multiplicity. Finally, we present expected exclusion limits with integrated luminosity, and demonstrate that with just a few 10s of fb{sup -1} we can expect to constrain the production modes of such a resonance. (orig.)

  20. Path integral measure for gravitational interactions

    Directory of Open Access Journals (Sweden)

    Kazuo Fujikawa

    1983-10-01

    Full Text Available It is pointed out that the path-integral variables as well as the local measure for gravitational interactions are uniquely specified if one imposes the anomaly-free condition on the Becchi-Rouet-Stora supersymmetry associated with general coordinate transformations. This prescription is briefly illustrated for the Einstein gravity and supergravity in four space-time dimensions and the relativistic string theory in two dimensions.

  1. In Search of an Integrative Measure of Functioning

    Directory of Open Access Journals (Sweden)

    Rosamond H. Madden

    2015-05-01

    Full Text Available International trends towards people-centred, integrative care and support require any measurement of functioning and disability to meet multiple aims. The information requirements of two major Australian programs for disability and rehabilitation are outlined, and the findings of two searches for suitable measures of functioning and disability are analysed. Over 30 current measures of functioning were evaluated in each search. Neither search found a generic measure of functioning suitable for these multibillion dollar programs, relevant to a wide range of people with a variety of health conditions and functioning experiences, and capable of indicating support needs, associated costs, progress and outcomes. This unsuccessful outcome has implications internationally for policy-relevant information for disability, rehabilitation and related programs. The paper outlines the features of an Integrative Measure of Functioning (IMF based on the concepts of functioning and environmental factors in the International Classification of Functioning, Disability and Health (ICF. An IMF would be applicable across a variety of health conditions, settings and purposes, ranging from individual assessment to public health. An IMF could deliver person-centred, policy-relevant information for a range of programs, promoting harmonised language and measurement and supporting international trends in human services and public health.

  2. Interference scattering effects on intermediate resonance absorption at operating temperatures

    International Nuclear Information System (INIS)

    Goldstein, R.

    1975-01-01

    Resonance integrals may be accurately calculated using the intermediate resonance (IR) approximation. Results are summarized for the case of an absorber with given potential scattering cross sections and interference scattering parameter admixed with a non absorbing moderator of given cross section and located in a narrow resonance moderating medium. From the form of the IR solutions, it is possible to make some general observations about effects of interference scattering on resonance absorption. 2 figures

  3. Measure and integral an introduction to real analysis

    CERN Document Server

    Wheeden, Richard L

    2015-01-01

    Now considered a classic text on the topic, Measure and Integral: An Introduction to Real Analysis provides an introduction to real analysis by first developing the theory of measure and integration in the simple setting of Euclidean space, and then presenting a more general treatment based on abstract notions characterized by axioms and with less geometric content.Published nearly forty years after the first edition, this long-awaited Second Edition also:Studies the Fourier transform of functions in the spaces L1, L2, and Lp, 1 p Shows the Hilbert transform to be a bounded operator on L2, as an application of the L2 theory of the Fourier transform in the one-dimensional caseCovers fractional integration and some topics related to mean oscillation properties of functions, such as the classes of Hölder continuous functions and the space of functions of bounded mean oscillationDerives a subrepresentation formula, which in higher dimensions plays a role roughly similar to the one played by the fundamental theor...

  4. Variational measures and the Kurzweil-Henstock integral

    Czech Academy of Sciences Publication Activity Database

    Schwabik, Štefan

    2009-01-01

    Roč. 59, č. 6 (2009), s. 731-752 ISSN 0139-9918 R&D Projects: GA AV ČR IAA100190702 Institutional research plan: CEZ:AV0Z10190503 Keywords : variational measure * Kurzweil-Henstock integral Subject RIV: BA - General Mathematics Impact factor: 0.308, year: 2009

  5. Sensing performance analysis on Fano resonance of metallic double-baffle contained MDM waveguide coupled ring resonator

    Science.gov (United States)

    Chen, Ying; Luo, Pei; Liu, Xiaofei; Di, Yuanjian; Han, Shuaitao; Cui, Xingning; He, Lei

    2018-05-01

    Based on the transmission property and the photon localization characteristic of the surface plasmonic sub-wavelength structure, a metallic double-baffle contained metal-dielectric-metal (MDM) waveguide coupled ring resonator is proposed. Like the electromagnetically induced transparency (EIT), the Fano resonance can be achieved by the interference between the metallic double-baffle resonator and the ring resonator. Based on the coupled mode theory, the transmission property is analyzed. Through the numerical simulation by the finite element method (FEM), the quantitative analysis on the influences of the radius R of the ring and the coupling distance g between the metallic double-baffle resonator and the ring resonator for the figure of merit (FOM) is performed. And after the structure parameter optimization, the sensing performance of the waveguide structure is discussed. The simulation results show that the FOM value of the optimized structure can attain to 5.74 ×104 and the sensitivity of resonance wavelength with refractive index drift is about 825 nm/RIU. The range of the detected refractive index is suitable for all gases. The waveguide structure can provide effective theoretical references for the design of integrated plasmonic devices.

  6. Quantum interference in the system of Lorentzian and Fano magnetoexciton resonances in GaAs

    International Nuclear Information System (INIS)

    Siegner, U.; Mycek, M.; Glutsch, S.; Chemla, D.S.

    1995-01-01

    Using femtosecond four-wave mixing (FWM), we study the coherent dynamics of Lorentzian and Fano magnetoexciton resonances in GaAs. For unperturbed Lorentzian magnetoexcitons, we find that the time-integrated FWM signal decays due to dephasing processes as expected for Lorentzian resonances. The time-integrated FWM signal from a single Fano magnetoexciton resonance, however, decays quasi-instantaneously although the dephasing time of the Fano resonance is much longer than the time resolution of the experiment. This fast decay is the manifestation of destructive quantum interference. Although destructive quantum interference in our system is closely related to the dynamics of Fano resonances, for the simultaneous excitation of Lorentzian and Fano magnetoexciton resonances destructive quantum interference also strongly affects the dynamics of Lorentzian magnetoexcitons due to quantum-mechanical coupling between the two types of resonances

  7. Comparison of Field Measurements and EMT Simulation Results on a Multi-Level STATCOM for Grid Integration of London Array Wind Power Plant

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Kocewiak, Łukasz Hubert; Hjerrild, Jesper

    2014-01-01

    Simulation results are widely used in the design of electrical systems such as offshore wind power plants (OWPPs) and for determination of grid compliance. Measurements constitute an important part in the evaluation process of the OWPP, including passive and active components such as the static...... of the STATCOM for wind power integration, as well as of the validity of applying a generic model of the STATCOM without knowledge of the actual implemented control system. The proposed model is integrated into an aggregated EMT model of LAOWPP, which will be used to investigate possible resonance phenomena...... that will be shown in the paper to affect the harmonic distortion level. The STATCOM distortion level will be shown to be highly affected by the number of wind turbine generators (WTGs) in service. It will be shown that the inclusion of band rejection filters (BRFs) in the WTGs’ control loop lowers the STATCOM...

  8. Measurement of specific heat and specific absorption rate by nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Gultekin, David H., E-mail: david.gultekin@aya.yale.edu [Department of Electrical Engineering, Yale University, New Haven, CT 06520 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10065 (United States); Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10065 (United States); Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232 (United States); Gore, John C. [Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232 (United States); Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232 (United States); Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN 37232 (United States); Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37232 (United States); Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232 (United States)

    2010-05-20

    We evaluate a nuclear magnetic resonance (NMR) method of calorimetry for the measurement of specific heat (c{sub p}) and specific absorption rate (SAR) in liquids. The feasibility of NMR calorimetry is demonstrated by experimental measurements of water, ethylene glycol and glycerol using any of three different NMR parameters (chemical shift, spin-spin relaxation rate and equilibrium nuclear magnetization). The method involves heating the sample using a continuous wave laser beam and measuring the temporal variation of the spatially averaged NMR parameter by non-invasive means. The temporal variation of the spatially averaged NMR parameter as a function of thermal power yields the ratio of the heat capacity to the respective nuclear thermal coefficient, from which the specific heat can be determined for the substance. The specific absorption rate is obtained by subjecting the liquid to heating by two types of radiation, radiofrequency (RF) and near-infrared (NIR), and by measuring the change in the nuclear spin phase shift by a gradient echo imaging sequence. These studies suggest NMR may be a useful tool for measurements of the thermal properties of liquids.

  9. Innovative Performance Measurement: an Integrative Perspective of Stakeholder's View

    Directory of Open Access Journals (Sweden)

    López-Fresno Palmira

    2014-11-01

    Full Text Available Business Process Management (BPM has been increasingly focused as an holistic approach to manage organizations for better organizational effectiveness. BPM involves the use of innovative performance measurement systems to follow up, coordinate, control and improve processes and overall business efficacy and efficiency. In this paper we propose a global holistic perspective of integrated information, combining the view of all stakeholders and both qualitative and quantitative information, as a basic prerequisite for quality of information for better decision making. The paper includes findings from an empirical case study of measuring Parkinson's Disease Neurosurgery process, including stakeholder's view with an integrative perspective.

  10. An improved intermediate resonance method for heterogeneous media

    International Nuclear Information System (INIS)

    Chiovato, O.; Corno, S.; Pasquantonio, F.Di.

    1977-01-01

    A new formulation is described of the Intermediate Resonance method which incorporates the previous developments suitably modified and improved, together with some new contributions. The 'intermediate' character is directly introduced in the integral operator K, allowing a more rigorous deduction of the equations for evaluating the intermediate parameters related to the nuclides involved in the system. There is no limit to the number of internal (admixed in the fuel) and external moderators. The capability to take into account the interference scattering has been extended to heterogeneous systems. The Doppler broadening is described by means of new accurate rational approximations to the broadened line shape psi. Finally the use of energy mean values suitably defined refines the values of the resonance integrals and resonance absorption cross sections. The Intermediate Resonance method so extended and improved, has been coded in a group of FORTRAN routines, which have been inserted as a calculation option in the fast section of the GGC code for the evaluation of multigroup cross sections. A series of calculations has been carried out, using these routines, and comparisons have been made with Monte Carlo and Nordheim's methods. The results obtained show that the Intermediate Resonance method developed in the present work offers considerable advantages over Nordheim's method: better accuracy in evaluating resonance absorption cross sections, and much smaller computing times. (author)

  11. Nanostructure Diffraction Gratings for Integrated Spectroscopy and Sensing

    Science.gov (United States)

    Guo, Junpeng (Inventor)

    2016-01-01

    The present disclosure pertains to metal or dielectric nanostructures of the subwavelength scale within the grating lines of optical diffraction gratings. The nanostructures have surface plasmon resonances or non-plasmon optical resonances. A linear photodetector array is used to capture the resonance spectra from one of the diffraction orders. The combined nanostructure super-grating and photodetector array eliminates the use of external optical spectrometers for measuring surface plasmon or optical resonance frequency shift caused by the presence of chemical and biological agents. The nanostructure super-gratings can be used for building integrated surface enhanced Raman scattering (SERS) spectrometers. The nanostructures within the diffraction grating lines enhance Raman scattering signal light while the diffraction grating pattern of the nanostructures diffracts Raman scattering light to different directions of propagation according to their wavelengths. Therefore, the nanostructure super-gratings allows for the use of a photodetector array to capture the surface enhanced Raman scattering spectra.

  12. Direct measurement for organic solvents diffusion using ultra-sensitive optical resonator

    Science.gov (United States)

    Ali, Amir R.; Elias, Catherine M.

    2017-06-01

    In this paper, novel techniques using ultra-sensitive chemical optical sensor based on whispering gallery modes (WGM) are proposed through two different configurations. The first one will use a composite micro-sphere, when the solvent interacts with the polymeric optical sensors through diffusion the sphere start to swallow that solvent. In turn, that leads to change the morphology and mechanical properties of the polymeric spheres. Also, these changes could be measured by tracking the WGM shifts. Several experiments were carried out to study the solvent induced WGM shift using microsphere immersed in a solvent atmosphere. It can be potentially used for sensing the trace organic solvents like ethanol and methanol. The second configuration will use a composite beam nitrocellulose composite (NC) structure that acts as a sensing element. In this configuration, a beam is anchored to a substrate in one end, and the other end is compressing the polymeric sphere causing a shift in its WGM. When a chemical molecule is attached to the beam, the resonant frequency of the cantilever will be changed for a certain amount. By sensing this certain resonant frequency change, the existence of a single chemical molecule can be detected. A preliminary experimental model is developed to describe the vibration of the beam structure. The resonant frequency change of the cantilever due to attached mass is examined imperially using acetone as an example. Breath diagnosis can use this configuration in diabetic's diagnosis. Since, solvent like acetone concentration in human breath leads to a quick, convenient, accurate and painless breath diagnosis of diabetics. These micro-optical sensors have been examined using preliminary experiments to fully investigate its response. The proposed chemical sensor can achieve extremely high sensitivity in molecular level.

  13. Two-path plasmonic interferometer with integrated detector

    Science.gov (United States)

    Dyer, Gregory Conrad; Shaner, Eric A.; Aizin, Gregory

    2016-03-29

    An electrically tunable terahertz two-path plasmonic interferometer with an integrated detection element can down convert a terahertz field to a rectified DC signal. The integrated detector utilizes a resonant plasmonic homodyne mixing mechanism that measures the component of the plasma waves in-phase with an excitation field that functions as the local oscillator in the mixer. The plasmonic interferometer comprises two independently tuned electrical paths. The plasmonic interferometer enables a spectrometer-on-a-chip where the tuning of electrical path length plays an analogous role to that of physical path length in macroscopic Fourier transform interferometers.

  14. Mars Atmospheric Entry Integrated Navigation with Partial Intermittent Measurements

    Directory of Open Access Journals (Sweden)

    Tai-shan Lou

    2017-01-01

    Full Text Available Signal degradation suffered by the vehicle is a combination brownout and blackout during Mars atmospheric entry. The communications brownout means that signal fades and blackout means that the signal is lost completely. The communications brownout and blackout periods are analyzed and predicted with an altitude and velocity profiles. In the brownout period, the range measurements between the vehicle and the orbiters are modeled as intermittent measurements with the radio signal arrival probabilities, which are distributed as a Rayleigh distribution of the electron number density around the entry vehicle. A new integrated navigation strategy during the Mars atmospheric entry phase is proposed to consider the probabilities of the radio measurements in the communications brownout and blackout periods under the IMU/beacon scenario based on the information filter with intermittent measurements. Numerical navigation simulations are designed to show the performance of the proposed navigation strategy under the integrated navigation scenario.

  15. Advanced resonance self-shielding method for gray resonance treatment in lattice physics code GALAXY

    International Nuclear Information System (INIS)

    Koike, Hiroki; Yamaji, Kazuya; Kirimura, Kazuki; Sato, Daisuke; Matsumoto, Hideki; Yamamoto, Akio

    2012-01-01

    A new resonance self-shielding method based on the equivalence theory is developed for general application to the lattice physics calculations. The present scope includes commercial light water reactor (LWR) design applications which require both calculation accuracy and calculation speed. In order to develop the new method, all the calculation processes from cross-section library preparation to effective cross-section generation are reviewed and reframed by adopting the current enhanced methodologies for lattice calculations. The new method is composed of the following four key methods: (1) cross-section library generation method with a polynomial hyperbolic tangent formulation, (2) resonance self-shielding method based on the multi-term rational approximation for general lattice geometry and gray resonance absorbers, (3) spatially dependent gray resonance self-shielding method for generation of intra-pellet power profile and (4) integrated reaction rate preservation method between the multi-group and the ultra-fine-group calculations. From the various verifications and validations, applicability of the present resonance treatment is totally confirmed. As a result, the new resonance self-shielding method is established, not only by extension of a past concentrated effort in the reactor physics research field, but also by unification of newly developed unique and challenging techniques for practical application to the lattice physics calculations. (author)

  16. Elastic moduli of faceted aluminum nitride nanotubes measured by contact resonance atomic force microscopy

    International Nuclear Information System (INIS)

    Stan, G; Cook, R F; Ciobanu, C V; Thayer, T P; Wang, G T; Creighton, J R; Purushotham, K P; Bendersky, L A

    2009-01-01

    A new methodology for determining the radial elastic modulus of a one-dimensional nanostructure laid on a substrate has been developed. The methodology consists of the combination of contact resonance atomic force microscopy (AFM) with finite element analysis, and we illustrate it for the case of faceted AlN nanotubes with triangular cross-sections. By making precision measurements of the resonance frequencies of the AFM cantilever-probe first in air and then in contact with the AlN nanotubes, we determine the contact stiffness at different locations on the nanotubes, i.e. on edges, inner surfaces, and outer facets. From the contact stiffness we have extracted the indentation modulus and found that this modulus depends strongly on the apex angle of the nanotube, varying from 250 to 400 GPa for indentation on the edges of the nanotubes investigated.

  17. Measurement of K(892)*0 resonance production in Pb-Pb collisions with the ALICE experiment at the LHC

    CERN Document Server

    Bellini, Francesca

    The analysis of the K(892)*0 resonance production in Pb–Pb collisions at √sNN = 2.76 TeV with the ALICE detector at the LHC is presented. The analysis is motivated by the interest in the measurement of short-lived resonances production that can provide insights on the properties of the medium produced in heavy-ion collisions both during its partonic (Quark-Gluon Plasma) and hadronic phase. This particular analysis exploits particle identification of the ALICE Time-Of-Flight detector. The ALICE experiment is presented, with focus on the performance of the Time-Of-Flight system. The aspects of calibration and data quality controls are discussed in detail, while illustrating the excellent and very stable performance of the system in different collision environments at the LHC. A full analysis of the K*0 resonance production is presented: from the resonance reconstruction to the determination of the efficiency and the systematic uncertainty. The results show that the analysis strategy discussed is a valid too...

  18. Neutron Activation Resonance Integrals of 74Se, 78Se, 80Se, 81Br, 127I, 130Te, 138Ba, 140Ce, and 142Ce

    International Nuclear Information System (INIS)

    Ricabarra, M. D.; Turjanskl, R.; Ricabarra, G. H.; Bigham, C.B.

    1968-01-01

    A lithium-drift germanium γ-ray spectrometer has been used to make accurate intercomparisons of the ratio of resonance-integral to thermal-activation cross section by measuring cadmium ratios or relative activation rates in two different neutron spectra. The standard, gold, or secondary standard, indium, was mixed uniformly in the samples and the activities resolved with the spectrometer. Expressed as Westcott S 0 values, the results relative to S 0 = 17.7 for gold were as follows: 74 Se = 10.3 +± 0.1, 78 Se = 12.3 ± 0.3, 80 Sc = 2.65 ± 0.02, 81 Br = 24.3 ± 0.5, 127 I = 27.8 ± 0.5, 130 Te = 2.10 ± 0.07, 138 Ba = 0.649 ± 0.004, 140 Ce = 0.476 ± 0.003, 142 Ce = 0.865 ± 0.005. (author)

  19. Electromagnetic resonance waves

    International Nuclear Information System (INIS)

    Villaba, J.M.; Manjon, F.J.; Guirao, A.; Andres, M.V.

    1994-01-01

    We describe in this paper a set of experiments designed to make qualitative and quantitative measurements on electromagnetic resonances of several simple systems. The experiments are designed for the undergraduate laboratory of Electricity and Magnetism in Physics. These experiments can help the students understanding the concept of resonance, which appears in different fields of Physics. (Author) 8 refs

  20. Packets of resonant modes in the Fermi–Pasta–Ulam system

    International Nuclear Information System (INIS)

    Genta, Tommaso; Giorgilli, Antonio; Paleari, Simone; Penati, Tiziano

    2012-01-01

    We reconsider the phenomenon of localization of energy in low frequency modes in the FPU system, exploiting the resonances in the lower part of the spectrum. Using the resonant normal form of Birkhoff we construct some candidates of approximate first integrals which we put in correspondence to packets of low frequency modes. By numerical calculation we show that the packet associated to the best quasi-integral involves all modes up to a frequency ω ⁎ (ε), where ε is the specific energy. The phenomenon disappears when the specific energy is bigger than a threshold value. The dependence of the relevant quantities on the number N of particles is also investigated. A final section is devoted to a first comparison with the Toda model. -- Highlights: ► We study the role of resonances for energy localization and metastability in the FPU model. ► We construct an approximated first integral associated to the metastable state. ► We propose to identify the metastable state as a packet of resonant modes. ► The packet extend up to a frequency ω ⁎ (ε), which depends only on the specific energy ε.