WorldWideScience

Sample records for resonance guidance progress

  1. Active instrumental guidance in interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wildermuth, S.; Erhart, P.; Leung, D.A.; Goehde, S.; Schoenenberger, A.; Debatin, J.F.

    1998-01-01

    Purpose: An active MR-based guidance system for visualisation of invasive instruments is described. Methods: The principle of MR tracking is based on the integration of a miniaturised coil into the tip of the instrument itself. A phantom experiment was designed to demonstrate the localising accuracy of this technique. In [dition, bicompatibility and warming effects were evaluated. Preliminary intravascular applications that were performed in animal experiments under MR guidance included embolisation, vascular occlusion as well as transjugular intrahepatic punctures. Percutaneous biopsies, cholecystostomies and laparoscopic applications were also evaluated with MR tracking. Results: Phantom experiments confirmed an excellent localisation accuracy of MR tracking compared to conventional r[iography. At a field strength of 0.5 T, the temperature increase remained below 2 C. Results of phantom experiments revealed a potential of significant heating dependent on the sequence parameters employed. MR tracking allowed a robust, simultaneously biplanar visualisation of the instrument tips in real time. Based on MR 'ro[ map' images, various intravascular and percutaneous interventions were successfully performed in vivo under MR guidance. Conclusions: MR tracking is a flexible concept permitting monitoring in the guidance of instruments in an MR environment. Various preliminary in vitro and in vivo experiments demonstrate safety, localisation accuracy and feasibility of this biplanar localisation technique in real time. (orig.) [de

  2. Progress in zirconium resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Page, R.H.; Dropinski, S.C.; Worden, E.F.; Stockdale, J.A.D.

    1993-01-01

    The authors have examined the stepwise-resonant three-photon-ionization spectrum of neutral zirconium atoms using three separately-tunable pulsed visible dye lasers. The ground-level (first-step) transitions were chosen on the basis of demonstrated 91 Zr selectivity. Lifetimes of even-parity levels around 36,000 cm -1 , measured with the delayed-photoionization technique, range from 10 to 100 nsec. Direct ionization cross sections appear to be less than 10 -17 cm 2 ; newly-detected autoionizing levels give peak ionization cross sections (inferred from saturation fluences) up to 10 -15 cm 2 . Portions of Rydberg series converging to the 315 and 763 cm -1 levels of Zr + were identified. Clumps of autoionizing levels are thought to be due to Rydberg-valence mixing

  3. Optical fiber tip interferometer gas pressure sensor based on anti-resonant reflecting guidance mechanism

    Science.gov (United States)

    Yang, Y. B.; Wang, D. N.; Xu, Ben; Wang, Z. K.

    2018-05-01

    We propose and demonstrate a gas pressure sensor based on an anti-resonant reflecting guidance (ARRG) mechanism in quartz capillary tube with an open cavity. The device is simple in fabrication by only fusion splicing a segment of capillary tube with single mode fiber. It has compact size, robust structure, convenient mode of operation, and high sensitivity of 4.278 nm/MPa. Moreover, as two Faby-Perot cavities exist in the device, which create the interference spectrum with several distinct resonance dips, a simultaneous gas pressure and temperature detection can be readily achieved by tracing two dip wavelengths. The error in the measurement due to the choice of different resonant dips can be effectively reduced by using the Fourier band pass filtering method.

  4. Fiber optic refractive index sensor using optofluidic anti-resonant reflecting guidance

    Science.gov (United States)

    Gao, Ran; Lu, Danfeng; Cheng, Jin; Qi, Zhi-mei

    2017-10-01

    An optofluidic anti-resonant reflecting guidance has been proposed and experimental demonstrated for the measurement of liquid refractive index. Two micro-channels were fabricated for the delivery of the liquid sample in the hollow core photonic crystal fiber by using femtosecond laser micromachining, serving as an inlet and outlet. The refractive index can be detected by using the resonant condition of the Fabry-Perot resonator, which is interrogated through the wavelength shift and of the lossy dip in the transmission spectrum. The experimental results show that the sensitivity of up to 1328 nm/RIU is achieved for the refractive index in the range from 1.345 to 1.363 RIU, respectively. The proposed sensor appears to have potential applications of precise measurement in chemistry, medicine, and biology.

  5. Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a 60Co Magnetic Resonance Image Guidance Radiation Therapy System

    International Nuclear Information System (INIS)

    Wooten, H. Omar; Green, Olga; Yang, Min; DeWees, Todd; Kashani, Rojano; Olsen, Jeff; Michalski, Jeff; Yang, Deshan; Tanderup, Kari; Hu, Yanle; Li, H. Harold; Mutic, Sasa

    2015-01-01

    Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating 60 Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create 60 Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The 60 Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All 60 Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for 60 Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all 60 Co plan OARs were within clinical tolerances. Conclusions: A commercial 60 Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system

  6. Global guidance on environmental life cycle impact assessment indicators: Progress and case study

    DEFF Research Database (Denmark)

    Frischknecht, Rolf; Fantke, Peter; Tschümperlin, Laura

    2016-01-01

    Purpose The life cycle impact assessment (LCIA) guidance flagship project of the United Nations Environment Programme (UNEP)/Society of Environmental Toxicology and Chemistry (SETAC) Life Cycle Initiative aims at providing global guidance and building scientific consensus on environmental LCIA in...

  7. Striking the Right Note: The Cultural Preparedness Approach to Developing Resonant Career Guidance Programmes

    Science.gov (United States)

    Arulmani, G.

    2011-01-01

    Cultural preparedness is presented as a conceptual framework that could guide the development of culture-resonant interventions. The "Jiva" careers programme is presented as a case study to illustrate a method of career and livelihood planning based upon Indian epistemology and cultural practices. Social cognitive environments and career beliefs…

  8. Effective progression of nuclear magnetic resonance-detected fragment hits.

    Science.gov (United States)

    Eaton, Hugh L; Wyss, Daniel F

    2011-01-01

    Fragment-based drug discovery (FBDD) has become increasingly popular over the last decade as an alternate lead generation tool to HTS approaches. Several compounds have now progressed into the clinic which originated from a fragment-based approach, demonstrating the utility of this emerging field. While fragment hit identification has become much more routine and may involve different screening approaches, the efficient progression of fragment hits into quality lead series may still present a major bottleneck for the broadly successful application of FBDD. In our laboratory, we have extensive experience in fragment-based NMR screening (SbN) and the subsequent iterative progression of fragment hits using structure-assisted chemistry. To maximize impact, we have applied this approach strategically to early- and high-priority targets, and those struggling for leads. Its application has yielded a clinical candidate for BACE1 and lead series in about one third of the SbN/FBDD projects. In this chapter, we will give an overview of our strategy and focus our discussion on NMR-based FBDD approaches. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Progress on resonance ionization detection of combustion radicals

    International Nuclear Information System (INIS)

    Cool, T.A.

    1994-01-01

    Selective laser ionization techniques are used in our laboratory for the measurement of concentration profiles of radical intermediates in the combustion of chlorinated hydrocarbon flames. A new ultrasensitive detection technique, made possible with the advent of tunable VUV laser sources, enables the selective near-threshold photoionization of all radical intermediates in premixed hydrocarbon and chlorinated hydrocarbon flames. The progress made on the following three separate experiments during the past year is briefly described in this report. Flame Radical Concentration Measurements with VUV Spectroscopy; observation of hyperfine quantum beats in cyanogen; and the spectroscopy of the ClCO radical

  10. Magnetic resonance imaging research progress on brain functional reorganization after peripheral nerve injury

    International Nuclear Information System (INIS)

    Wang Weiwei; Liu Hanqiu

    2013-01-01

    In the recent years, with the development of functional magnetic resonance imaging technology the brain plasticity and functional reorganization are hot topics in the central nervous system imaging studies. Brain functional reorganization and rehabilitation after peripheral nerve injury may have certain regularity. In this paper, the progress of brain functional magnetic resonance imaging technology and its applications in the world wide clinical and experimental researches of the brain functional reorganization after peripheral nerve injury is are reviewed. (authors)

  11. Guidance for growth factors, projections, and control strategies for the 15 percent rate-of-progress plans

    International Nuclear Information System (INIS)

    1993-03-01

    Section 182(b)(1) of the Clean Air Act (Act) requires all ozone nonattainment areas classified as moderate and above to submit a State Implementation Plan (SIP) revision by November 15, 1993, which describes, in part, how the areas will achieve an actual volatile organic compound (VOC) emissions reduction of at least 15 percent during the first 6 years after enactment of the Clean Air Act Amendments of 1990 (CAAA). In addition, the SIP revision must describe how any growth in emissions from 1990 through 1996 will be fully offset. It is important to note that section 182(b)(1) also requires the SIP for moderate areas to provide for reductions in VOC and nitrogen oxides (NOx) emissions as necessary to attain the national primary ambient air quality standard for ozone by November 15, 1996. The guidance document focuses on the procedures for developing 1996 projected emissions inventories and control measures which moderate and above ozone nonattainment areas must include in their rate-of-progress plans. The document provides technical guidance to support the policy presented in the 'General Preamble: Implementation of Title I of the CAAA of 1990' (57 FR 13498)

  12. Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a ⁶⁰Co Magnetic Resonance Image Guidance Radiation Therapy System.

    Science.gov (United States)

    Wooten, H Omar; Green, Olga; Yang, Min; DeWees, Todd; Kashani, Rojano; Olsen, Jeff; Michalski, Jeff; Yang, Deshan; Tanderup, Kari; Hu, Yanle; Li, H Harold; Mutic, Sasa

    2015-07-15

    This work describes a commercial treatment planning system, its technical features, and its capabilities for creating (60)Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. The ViewRay treatment planning system (Oakwood Village, OH) was used to create (60)Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The (60)Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. All (60)Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for (60)Co was within 20 Gy. The mean doses for all (60)Co plan OARs were within clinical tolerances. A commercial (60)Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Work in progress: nuclear magnetic resonance imaging of the gallbladder

    International Nuclear Information System (INIS)

    Hricak, H.; Filly, R.A.; Margulis, A.R.; Moon, K.L.; Crooks, L.E.; Kaufman, L.

    1983-01-01

    A preliminary study of the relation between food intake and intensity of gallbladder bile on nuclear magnetic resonance (NMR) images was made. Twelve subjects (seven volunteers, five patients) were imaged following a minimum of 14 hours of fasting. Six of seven volunteers were reimaged one hour after stimulation by either a fatty meal or an alcoholic beverage. An additional seven patients were imaged two hours after a hospital breakfast. It was found that concentrated bile emits a high-intensity spin echo signal (SE), while hepatic bile in the gallbladder produces a low-intensity SE signal. Following ingestion of cholecystogogue, dilute hepatic bile settles on top of the concentrated bile, each emitting SE signals of different intensity. The average T1 value of concentrated bile was 594 msec, while the T1 vaue of dilute hepatic bile was 2,646 msec. The average T2 values were 104 msec for concentrated bile and 126 msec for dilute bile. The most likely cause for the different SE intensities of bile is the higher water content, and therefore longer T1 or T2 relaxation times, of hepatic bile. It is suggested that NMR imaging has the ability to provide physiological information about the gallbladder and that it may prove to be a simple and safe clinical test of gallbladder function

  14. Progressive and resonant wave helices application to electron paramagnetic resonance; Helices a ondes progressives et resonnantes application a la resonance paramagnetique electronique

    Energy Technology Data Exchange (ETDEWEB)

    Volino, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    We show that helices can be used as resonant systems. Their properties are theoretically and experimentally studied. We describe resonant helices for electron paramagnetic resonance in X-band and develop a comparison between their sensitivity and the sensitivity of a normal resonant cavity. For cylindrical samples less than 3 mm diameter, the helix is more sensitive and can produce more intense microwave magnetic fields. (author) [French] Il est montre que les helices peuvent etre utilisees comme systeme resonnant. Leurs proprietes sont discutees theoriquement et experimentalement. Des helices resonnantes en bande X pour la resonance paramagnetique electronique sont decrites et leur sensibilite est comparee a celle des cavites resonnantes. Pour des echantillons cylindriques de moins de 3 mm de diametre, l'helice est plus sensible et peut produire des champs magnetiques hyper fins plus intenses. (auteur)

  15. Progressive and resonant wave helices application to electron paramagnetic resonance; Helices a ondes progressives et resonnantes application a la resonance paramagnetique electronique

    Energy Technology Data Exchange (ETDEWEB)

    Volino, F. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    We show that helices can be used as resonant systems. Their properties are theoretically and experimentally studied. We describe resonant helices for electron paramagnetic resonance in X-band and develop a comparison between their sensitivity and the sensitivity of a normal resonant cavity. For cylindrical samples less than 3 mm diameter, the helix is more sensitive and can produce more intense microwave magnetic fields. (author) [French] Il est montre que les helices peuvent etre utilisees comme systeme resonnant. Leurs proprietes sont discutees theoriquement et experimentalement. Des helices resonnantes en bande X pour la resonance paramagnetique electronique sont decrites et leur sensibilite est comparee a celle des cavites resonnantes. Pour des echantillons cylindriques de moins de 3 mm de diametre, l'helice est plus sensible et peut produire des champs magnetiques hyper fins plus intenses. (auteur)

  16. Cardiac magnetic resonance markers of progressive RV dilation and dysfunction after tetralogy of Fallot repair

    NARCIS (Netherlands)

    Wald, Rachel M.; Valente, Anne Marie; Gauvreau, Kimberlee; Babu-Narayan, Sonya V.; Assenza, Gabriele Egidy; Schreier, Jenna; Gatzoulis, Michael A.; Kilner, Philip J.; Koyak, Zeliha; Mulder, Barbara; Powell, Andrew J.; Geva, Tal

    2015-01-01

    Patients with repaired tetralogy of Fallot (TOF) are followed serially by cardiac magnetic resonance (CMR) for surveillance of RV dilation and dysfunction. We sought to define the prevalence of progressive RV disease and the optimal time interval between CMR evaluations. Candidates were selected

  17. Specific magnetic resonance imaging findings in patient with progressive supranuciear palsy

    International Nuclear Information System (INIS)

    Vuchkova, R.; Zlatareva, D.

    2013-01-01

    Progressive supranuclear palsy (PSP) is a progressive neurodegenerative disease. The clinical symptoms are vertical supranuclear palsy, gait and postural instability, cognitive deficit, Parkinsonism. It is not always possible to differentiate clinically PSP from other atypical Parkinsonian syndromes and from Parkinson disease. We present a case of 56-years old women with clinically suspected PSP. The typical magnetic resonance findings were of most importance in diagnosis. For diagnosing the disease by means of neuroimaging it is necessary to analyze the sagittal MR images what is achievable in daily routine practice without additional software and post processing. (authors)

  18. Magnetic resonance imaging in patients with progressive myelopathy following spinal surgery.

    OpenAIRE

    Avrahami, E; Tadmor, R; Cohn, D F

    1989-01-01

    Thirty one patients with insidious progressive myelopathy 2 to 8 years following surgery of the cervical spine were subjected to magnetic resonance imaging (MRI). In 15 patients operated on for vascular malformations or intramedullary tumours, syringomyelia and cystic lesions of the spinal cord were shown. Seven of these patients also showed a combination of a recurrent tumour and spinal atrophy. Out of 16 patients who had surgery for herniated disc or spinal stenosis of the cervical spine, f...

  19. The Angle of Progression at Station 0 and in Magnetic Resonance and Transperineal Ultrasound Assessment

    Directory of Open Access Journals (Sweden)

    D. Iliescu

    2015-01-01

    Full Text Available The transperineal ultrasound (TPU value of the angle of progression (AOP during fetal head engagement, at station 0, is a critical cut-off for current obstetrical practice, especially when intrapartum instrumental interventions are required. Still, controversial measurements were reported in previous high resolution imagistic studies. Our TPU and direct “gold-standard” magnetic resonance (MRI measurements confirm that station 0 corresponds to a 120° AOP, concordantly. Based on these findings, the fact that an AOP of 120° or greater was previously strongly associated with vaginal delivery may be due to the achievement of head engagement in labor.

  20. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    OBJECTIVES: The purpose of this study was to investigate the detection rate of prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsies (mp-MRI-bx) in patients with prior negative transrectal ultrasound biopsy (TRUS-bx) sessions without previous experience of this......-RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...

  1. Proton resonance spectroscopy. Quarterly technical progress report, December 1992--November 1995

    International Nuclear Information System (INIS)

    Shriner, J.F. Jr.

    1995-11-01

    Work on chaos in the low-lying levels of nuclei has continued on several fronts. The major effort has been study of the 29 Si(p,γ) reaction with the goal of establishing a complete level scheme for 30 P and analyzing the eigenvalue fluctuations for evidence of chaos. These measurements are in progress, and the current status is described. A related topic is the search for different signatures of chaos which do not require the extremely high degree of completeness and purity necessary for eigenvalue analyses; those efforts are discussed in Sections 2 and 3. The possibility of studying both parity violation and time-reversal invariance violation with charged particle resonances has been explored by performing calculations using experimentally measured resonance parameters. Large enhancements are indeed available; the results are discussed in Sections 4 and 5. Preparations for an experimental study of parity violation using these techniques are ongoing. An undergraduate project searching for experimental evidence of a parity dependence of level density is discussed in Section 6. A number of improvements to the operation of the TUNL KN accelerator have been implemented in the past three years. These are described in Section 7

  2. Proton resonance spectroscopy. Quarterly technical progress report, December 1992--November 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shriner, J.F. Jr.

    1995-11-01

    Work on chaos in the low-lying levels of nuclei has continued on several fronts. The major effort has been study of the {sup 29}Si(p,{gamma}) reaction with the goal of establishing a complete level scheme for {sup 30}P and analyzing the eigenvalue fluctuations for evidence of chaos. These measurements are in progress, and the current status is described. A related topic is the search for different signatures of chaos which do not require the extremely high degree of completeness and purity necessary for eigenvalue analyses; those efforts are discussed in Sections 2 and 3. The possibility of studying both parity violation and time-reversal invariance violation with charged particle resonances has been explored by performing calculations using experimentally measured resonance parameters. Large enhancements are indeed available; the results are discussed in Sections 4 and 5. Preparations for an experimental study of parity violation using these techniques are ongoing. An undergraduate project searching for experimental evidence of a parity dependence of level density is discussed in Section 6. A number of improvements to the operation of the TUNL KN accelerator have been implemented in the past three years. These are described in Section 7.

  3. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now

    Energy Technology Data Exchange (ETDEWEB)

    Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Banfi, Giuseppe [IRCCS Istituto Ortopedico Galeazzi, Milano (Italy); Universita Vita-Salute San Raffaele, Milano (Italy); Aliprandi, Alberto [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Mauri, Giovanni [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Istituto Europeo di Oncologia, Unita di Radiologia Interventistica, Milano (Italy); Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); IRCCS Policlinico San Donato, Servizio di Radiologia, San Donato, Milanese (Italy)

    2016-05-15

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. (orig.)

  4. Development and validation of rheumatoid arthritis magnetic resonance imaging inflammation thresholds associated with lack of damage progression

    DEFF Research Database (Denmark)

    Baker, Joshua F.; Østergaard, Mikkel; Emery, Paul

    2017-01-01

    Objective To determine thresholds for rheumatoid arthritis (RA) magnetic resonance imaging scores (RAMRIS) associated with a low risk of structural damage progression. Methods MRI of the dominant hand was performed and RAMRIS scores determined at weeks 0, 24, and 52. X-rays were performed and van...

  5. Early Magnetic Resonance Detection of Natalizumab-Related Progressive Multifocal Leukoencephalopathy in a Patient with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Guglielmo Manenti

    2013-01-01

    Full Text Available Diagnosis of progressive multifocal leukoencephalopathy is usually based on the clinical presentation, on the demonstration of the brain lesions at the magnetic resonance imaging examination, and on the detection of the JC virus DNA in the cerebrospinal fluid with high sensitive polymerase chain reaction. The role of magnetic resonance imaging specifically in natalizumab-associated progressive multifocal leukoencephalopathy is strengthening, and it is gaining importance not only as an irreplaceable diagnostic tool but also as a surveillance and risk stratifying tool in treated patients. While other imaging techniques such as computed tomography lack sensitivity and specificity, magnetic resonance performed with morphological and functional sequences offers clinicians the possibility to early identify the stage of the disease and the emergence of an immune reconstitution inflammatory syndrome after natalizumab blood removal plasmapheresis.

  6. Progress and promises of human cardiac magnetic resonance at ultrahigh fields: a physics perspective.

    Science.gov (United States)

    Niendorf, Thoralf; Graessl, Andreas; Thalhammer, Christof; Dieringer, Matthias A; Kraus, Oliver; Santoro, Davide; Fuchs, Katharina; Hezel, Fabian; Waiczies, Sonia; Ittermann, Bernd; Winter, Lukas

    2013-04-01

    A growing number of reports eloquently speak about explorations into cardiac magnetic resonance (CMR) at ultrahigh magnetic fields (B0≥7.0 T). Realizing the progress, promises and challenges of ultrahigh field (UHF) CMR this perspective outlines current trends in enabling MR technology tailored for cardiac MR in the short wavelength regime. For this purpose many channel radiofrequency (RF) technology concepts are outlined. Basic principles of mapping and shimming of transmission fields including RF power deposition considerations are presented. Explorations motivated by the safe operation of UHF-CMR even in the presence of conductive implants are described together with the physics, numerical simulations and experiments, all of which detailing antenna effects and RF heating induced by intracoronary stents at 7.0 T. Early applications of CMR at 7.0 T and their clinical implications for explorations into cardiovascular diseases are explored including assessment of cardiac function, myocardial tissue characterization, MR angiography of large and small vessels as well as heteronuclear MR of the heart and the skin. A concluding section ventures a glance beyond the horizon and explores future directions. The goal here is not to be comprehensive but to inspire the biomedical and diagnostic imaging communities to throw further weight behind the solution of the many remaining unsolved problems and technical obstacles of UHF-CMR with the goal to transfer MR physics driven methodological advancements into extra clinical value. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Extracellular diffusion quantified by magnetic resonance imaging during rat C6 glioma cell progression

    Directory of Open Access Journals (Sweden)

    G. Song

    Full Text Available Solution reflux and edema hamper the convection-enhanced delivery of the standard treatment for glioma. Therefore, a real-time magnetic resonance imaging (MRI method was developed to monitor the dosing process, but a quantitative analysis of local diffusion and clearance parameters has not been assessed. The objective of this study was to compare diffusion into the extracellular space (ECS at different stages of rat C6 gliomas, and analyze the effects of the extracellular matrix (ECM on the diffusion process. At 10 and 20 days, after successful glioma modeling, gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA was introduced into the ECS of rat C6 gliomas. Diffusion parameters and half-life of the reagent were then detected using MRI, and quantified according to the mathematical model of diffusion. The main ECM components [chondroitin sulfate proteoglycans (CSPGs, collagen IV, and tenascin C] were detected by immunohistochemical and immunoblot analyses. In 20-day gliomas, Gd-DTPA diffused more slowly and derived higher tortuosity, with lower clearance rate and longer half-life compared to 10-day gliomas. The increased glioma ECM was associated with different diffusion and clearance parameters in 20-day rat gliomas compared to 10-day gliomas. ECS parameters were altered with C6 glioma progression from increased ECM content. Our study might help better understand the glioma microenvironment and provide benefits for interstitial drug delivery to treat brain gliomas.

  8. Toward single-mode UV to near-IR guidance using hollow-core anti-resonant silica fiber

    DEFF Research Database (Denmark)

    Habib, Md Selim; Antonio-Lopez, Jose Enrique; Van Newkirk, Amy

    2017-01-01

    Hollow-core anti-resonant (HC-AR) fibers with a “negative-curvature” of the core-cladding boundary have been extensively studied over the past few years owing to their low loss and wide transmission bandwidths. The key unique feature of the HC-AR fiber is that the coupling between the core and cl...... a silica HC-AR fiber having a single ring of 7 non-touching capillaries, designed to have effectively single-mode operation and low loss from UV to near-IR....

  9. The axon guidance molecule semaphorin 3F is a negative regulator of tumor progression and proliferation in ileal neuroendocrine tumors

    Science.gov (United States)

    Vercherat, Cécile; Blanc, Martine; Lepinasse, Florian; Gadot, Nicolas; Couderc, Christophe; Poncet, Gilles; Walter, Thomas; Joly, Marie-Odile; Hervieu, Valérie; Scoazec, Jean-Yves; Roche, Colette

    2015-01-01

    Gastro-intestinal neuroendocrine tumors (GI-NETs) are rare neoplasms, frequently metastatic, raising difficult clinical and therapeutic challenges due to a poor knowledge of their biology. As neuroendocrine cells express both epithelial and neural cell markers, we studied the possible involvement in GI-NETs of axon guidance molecules, which have been shown to decrease tumor cell proliferation and metastatic dissemination in several tumor types. We focused on the role of Semaphorin 3F (SEMA3F) in ileal NETs, one of the most frequent subtypes of GI-NETs. SEMA3F expression was detected in normal neuroendocrine cells but was lost in most of human primary tumors and all their metastases. SEMA3F loss of expression was associated with promoter gene methylation. After increasing endogenous SEMA3F levels through stable transfection, enteroendocrine cell lines STC-1 and GluTag showed a reduced proliferation rate in vitro. In two different xenograft mouse models, SEMA3F-overexpressing cells exhibited a reduced ability to form tumors and a hampered liver dissemination potential in vivo. This resulted, at least in part, from the inhibition of mTOR and MAPK signaling pathways. This study demonstrates an anti-tumoral role of SEMA3F in ileal NETs. We thus suggest that SEMA3F and/or its cellular signaling pathway could represent a target for ileal NET therapy. PMID:26447612

  10. Resonance enhanced multiphoton ionization spectra of molecules and molecular fragments. Annual progress report, March 1992 - February 1993

    International Nuclear Information System (INIS)

    1993-01-01

    In this report, the author will review the progress made in his studies of ion rotational distributions resulting from resonance enhanced multiphoton ionization of excited electronic states and from single-photon ionization of ground electronic states of jet-cooled molecules by coherent VUV and XUV radiation. To do so he will select a few examples from his studies which serve to highlight his progress and to identify the background and significance of the specific spectral features and systems he has chosen to study

  11. Progresses in the studies of adiabatic splitting of charged particle beams by crossing nonlinear resonances

    Directory of Open Access Journals (Sweden)

    A. Franchi

    2009-01-01

    Full Text Available The multiturn extraction from a circular particle accelerator is performed by trapping the beam inside stable islands of the horizontal phase space. In general, by crossing a resonance of order n, n+1 beamlets are created whenever the resonance is stable, whereas if the resonance is unstable the beam is split in n parts. Islands are generated by nonlinear magnetic fields, whereas the trapping is realized by means of a given tune variation so to cross adiabatically a resonance. Experiments at the CERN Proton Synchrotron carried out in 2007 gave the evidence of protons trapped in stable islands while crossing the one-third and one-fifth resonances. Dedicated experiments were also carried out to study the trapping process and its reversibility properties. The results of these measurement campaigns are presented and discussed in this paper.

  12. Progresses in the Studies of Adiabatic Splitting of Charged Particles Beams by Crossing Nonlinear Resonances

    CERN Document Server

    Franchi, A; Giovannozzi, M; CERN. Geneva. BE Department

    2009-01-01

    The multi-turn extraction from a circular particle accelerator is performed by trapping the beam inside stable islands of the horizontal phase space. In general, by crossing a resonance of order n, n+1 beamlets are created whenever the resonance is stable, whereas if the resonance is unstable the beam is split in n parts. Islands are generated by non-linear magnetic fields, whereas the trapping is realized by means of a given tune variation so to cross adiabatically a resonance. Experiments at the CERN Proton Synchrotron carried out in 2007 gave the evidence of protons trapped in stable islands while crossing the one-third and one-fifth resonances. Dedicated experiments were also carried out to study the trapping process and its reversibility properties. The results of these measurement campaigns are presented and discussed in this paper.

  13. Resonance

    DEFF Research Database (Denmark)

    Petersen, Nils Holger

    2014-01-01

    A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice.......A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice....

  14. Surface nuclear magnetic resonance imaging of water content distribution in the subsurface. 1998 annual progress report

    International Nuclear Information System (INIS)

    Hendrickx, J.M.H.

    1998-01-01

    'The objective of the project is to evaluate Surface Nuclear Magnetic Resonance Imaging ( NMRI) for determining water content distribution in the subsurface. In NMRI the interaction of the magnetic moment of hydrogen ( protons) nuclei with external applied electromagnetic ( EM ) fields is measured. In surface NMRI the Earth''s magnetic field causes alignment of the spinning protons. An alternating EM field is generated by a loop of wire laid on the Earth surface. The alternating current driven through the loop at the Lamor frequency of protons in liquid water. The component of the EM field perpendicular to the Earth''s field causes a precession of protons from their equilibrium position. Water content distribution in the subsurface is derived from measurements on the EM field caused by the return of the precessing protons to equilibrium after the current in the transmitter loop is terminated. The scientific goals of the R and D are: to verify and validate the theoretical concepts and experimental results of Russian scientists, who first introduced this method; to evaluate the range of applications and limitations of this technology for practical field measurements. NMRI has the potential of providing a remote, direct, unique method for subsurface water measurements. All present methods are either intrusive or indirect ( e.g. electrical resitivity measurements). In the past year progress has been made along two separate paths. These are: (1) Field Measurements. Surface NMRI equipment manufactured by IRIS Instruments of France was tested over a number of sites with good hydrogeologic control. The results of these measurements can be summarized as follows: The NMRI measurement directly and uniquely determines water distribution in coarse grained aquifers; geologic formation from which water can be readily withdrawn. Water content can not be determined by this technique in fine grained sediments. The signal to be measured is very small and EM interference''s from power

  15. Custom-designed Laser-based Heating Apparatus for Triggered Release of Cisplatin from Thermosensitive Liposomes with Magnetic Resonance Image Guidance.

    Science.gov (United States)

    Dou, Yannan N; Weersink, Robert A; Foltz, Warren D; Zheng, Jinzi; Chaudary, Naz; Jaffray, David A; Allen, Christine

    2015-12-13

    Liposomes have been employed as drug delivery systems to target solid tumors through exploitation of the enhanced permeability and retention (EPR) effect resulting in significant reductions in systemic toxicity. Nonetheless, insufficient release of encapsulated drug from liposomes has limited their clinical efficacy. Temperature-sensitive liposomes have been engineered to provide site-specific release of drug in order to overcome the problem of limited tumor drug bioavailability. Our lab has designed and developed a heat-activated thermosensitive liposome formulation of cisplatin (CDDP), known as HTLC, to provide triggered release of CDDP at solid tumors. Heat-activated delivery in vivo was achieved in murine models using a custom-built laser-based heating apparatus that provides a conformal heating pattern at the tumor site as confirmed by MR thermometry (MRT). A fiber optic temperature monitoring device was used to measure the temperature in real-time during the entire heating period with online adjustment of heat delivery by alternating the laser power. Drug delivery was optimized under magnetic resonance (MR) image guidance by co-encapsulation of an MR contrast agent (i.e., gadoteridol) along with CDDP into the thermosensitive liposomes as a means to validate the heating protocol and to assess tumor accumulation. The heating protocol consisted of a preheating period of 5 min prior to administration of HTLC and 20 min heating post-injection. This heating protocol resulted in effective release of the encapsulated agents with the highest MR signal change observed in the heated tumor in comparison to the unheated tumor and muscle. This study demonstrated the successful application of the laser-based heating apparatus for preclinical thermosensitive liposome development and the importance of MR-guided validation of the heating protocol for optimization of drug delivery.

  16. ResonantSonic drilling: History, progress, and advances in environmental restoration programs

    International Nuclear Information System (INIS)

    Moak, D.J.

    1995-01-01

    ResonantSonic drilling is being used in the environmental industry to drill faster, cheaper, and safer than conventional drilling methodologies. The ResonantSonic drilling method requires no mud, air, or water for rapid penetration through geologic materials ranging from rock and clay to sand and boulders. A specialized drill head imparts high frequency vibrations into steel drill pipe and creates a drilling action which allows the retrieval of continuous, undisturbed cores. An added benefit is that the method can be used for angle drilling. The ResonantSonic method has been used in the past for projects ranging from pile driving to horizontal drilling. Current programs utilize the technique as a valuable tool for obtaining in situ, pristine environmental samples. In the future, this drilling technology could be used for remote, automated sampling at hazardous waste sites

  17. ResonantSonic drilling: History, progress and advances in environmental restoration programs

    International Nuclear Information System (INIS)

    Volk, B.W.; McLellan, G.W.; Moak, D.J.; Lerch, R.E.; Thompson, K.M.; Barrow, J.C.

    1993-01-01

    ResonantSonic SM drilling is being used in the environmental industry to drill faster, cheaper, and safer than conventional drilling methodologies. ResonantSonic is a registered service mark of the Water Development Corporation, Woodland, California. The ResonantSonic drilling method, requires no mud, air or water for rapid penetration through geologic materials ranging from rock and clay to sand and boulders. The specialized drill head imparts high frequency vibrations into a steel drill pipe creating a drilling action which allows the retrieval of continuous, undisturbed cores. An added benefit is that the method can be used for angle drilling. The ReasonantSonic method has been used in the past for projects ranging from pile driving to horizontal drilling. Current programs are utilizing the technique as a valuable tool for obtaining in situ, pristine environmental samples. In the future, this drilling technology could be used for remote, automated sampling at hazardous waste sites

  18. Microwave-optical double resonance spectroscopy. Progress report, February 1, 1978--January 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, D.W.

    1978-11-01

    Optical, zero-field and high-field optical detection of magnetic resonance, electron-nuclear double resonance, level anticrossing and cross relaxation, and electron paramagnetic resonance experiments have been performed on a variety of chemical systems in order to further basic knowledge of the structure, reactivity, and response to radiation of molecules in their ground and/or excited electronic states. Systems investigated include organic molecules oriented in low temperature crystals, simple free radicals, transition metal complexes, rare earth hydrides, and hemeproteins in biological enzymes. Aside from their intrinsic interest, many of these systems are of potential importance in a number of applied areas including hydrocarbon-based fuel systems, solar energy devices, laser-initiated photochemical reactions, and free radical mechanisms in chemical carcinogenesis.

  19. Microwave-optical double resonance spectroscopy. Progress report, February 1, 1978--January 31, 1979

    International Nuclear Information System (INIS)

    Pratt, D.W.

    1978-01-01

    Optical, zero-field and high-field optical detection of magnetic resonance, electron-nuclear double resonance, level anticrossing and cross relaxation, and electron paramagnetic resonance experiments have been performed on a variety of chemical systems in order to further basic knowledge of the structure, reactivity, and response to radiation of molecules in their ground and/or excited electronic states. Systems investigated include organic molecules oriented in low temperature crystals, simple free radicals, transition metal complexes, rare earth hydrides, and hemeproteins in biological enzymes. Aside from their intrinsic interest, many of these systems are of potential importance in a number of applied areas including hydrocarbon-based fuel systems, solar energy devices, laser-initiated photochemical reactions, and free radical mechanisms in chemical carcinogenesis

  20. Magnetic resonance imaging may simulate progressive multifocal leucoencephalopathy in a patient with chronic lymphocytic leukemia after fludarabine therapy

    Directory of Open Access Journals (Sweden)

    Kalita J

    2008-01-01

    Full Text Available A 60-year-old male with chronic lymphatic leukemia (CLL after 6 months of fludarabine therapy was admitted with status epilepticus and developed left hemiplegia. His magnetic resonance imaging revealed multiple T2 hyperintense lesions in the right frontal and left parieto-occipital lesion, simulating progressive multifocal leucoencephalopathy (PML. Cerebrospinal fluid Polymerase Chain Reaction (PCR for JC virus was negative. We suggest the possible role of fludarabine in producing PML-like lesions in patients with Chronic Lymphocytic Leukemia (CLL.

  1. Experimental test of resonant absorption theory. Annual progress report, January 1, 1979-December 31, 1979

    International Nuclear Information System (INIS)

    Yablonovitch, E.

    1979-09-01

    New results are reported on the angular and energy spectrum of resonantly accelerated electrons from a shock front as measured by a miniature β-ray spectrometer. We have devised a multichannel electron collector based on printed circuit board technology. It has been multiplexed into a fast oscilloscope to provide a complete absolute spectrum on a single laser shot

  2. The chameleon of neuroinflammation : magnetic resonance imaging characteristics of natalizumab-associated progressive multifocal leukoencephalopathy

    NARCIS (Netherlands)

    Wattjes, Mike P.; Richert, Nancy D.; Killestein, Joep; de Vos, Marlieke; Sanchez, Esther; Snaebjornsson, Petur; Cadavid, Diego; Barkhof, Frederik

    2013-01-01

    Natalizumab is a monoclonal antibody against 4-integrin approved for the treatment of multiple sclerosis (MS) due to a positive effect on clinical and magnetic resonance imaging (MRI) outcome measures. However, one relatively rare but serious side effect of this drug is a higher risk of developing

  3. Resonances

    DEFF Research Database (Denmark)

    an impetus or drive to that account: change, innovation, rupture, or discontinuity. Resonances: Historical Essays on Continuity and Change explores the historiographical question of the modes of interrelation between these motifs in historical narratives. The essays in the collection attempt to realize...

  4. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  5. Near resonant absorption by atoms in intense, fluctuating fields: [Progress report

    International Nuclear Information System (INIS)

    1989-01-01

    During the present grant period preparations for photon echo studies of the role of phase fluctuations of an optical driving field resonant with the 1 S 0 - 3 P 1 transition in 174 Yb are moving forward. This experimental study emphasizes the role of fluctuations as a decorrelating mechanism on a phased array of excited atoms. Improvements in laser stabilization and in the quality of the fluctuation spectrum have been carried out and the first spectroscopic measurements will be carried out during this grant year. In response to an important recent theoretical study we have also applied the phase fluctuation synthesizing capability to the study of the atomic sodium resonance fluorescence line profile, driven by a phase fluctuating laser. The measured fluctuations in the fluorescence, characterized in terms of the standard deviation of the fluorescence intensity, have an unexpected and strong dependence on detuning of the driving laser

  6. High-pressure electron-resonance studies of electronic, magnetic, and structural phase transitions. Progress report

    International Nuclear Information System (INIS)

    Pifer, J.H.; Croft, M.C.

    1983-01-01

    Research is described in development of a high-pressure electron-resonance probe capable of operating down to 1.5 0 K temperatures. The apparatus has been used to measure the EPR of a sample of DPPH at room temperature and zero pressure. EPR has been used to measure valence field instabilities in alloy systems. Studies have been done on metal-insulator transitions at high pressure, and are briefly described

  7. Microwave-optical double resonance spectroscopy. Progress report, February 1, 1975--January 31, 1976

    International Nuclear Information System (INIS)

    Pratt, D.W.

    1975-01-01

    Zero-field and high-field optical detection of magnetic resonance (ODMR), electron paramagnetic resonance (EPR), and optical spectroscopy experiments were performed on several systems in order to further basic knowledge of the structure, reactions, and response to radiation of atoms, molecules, and ions. Results on the following studies are reported: the direct observation of level anticrossing and mixing effects in excited molecular triplet states; anomalous zero-field splittings in the lowest triplet state of 1-iodonaphthalene; evidence for second-order spin-orbit coupling and spin delocalization effects in the lowest triplet state of benzophenone; direct observation of the optical absorption spectra of reactive free radicals at room temperature; measurements of the activation and thermodynamic parameters of several cyclohexenyl and cyclohexanonyl radicals; complete analyses of the level anticrossing and cross relaxation spectra of oriented molecular triplet states; solutions to the spin Hamiltonian for S = 1, I = 5/2 systems in both zero-field and high-field, an improvement by a factor of ten in the resolution of ODMR experiments in high field; and measurements of the optical and magnetic resonance properties of a series of halogenated naphthalenes in their lowest triplet states

  8. Progress of magnetic resonance spectroscopy in chronic renal failure patients with vertebral bone change

    International Nuclear Information System (INIS)

    Gao Cailiang; Dong Guoli; Zeng Nanlin

    2013-01-01

    Bone changes caused by kidney diseases affect the quality of life in the patients with chronic renal failure. How to improve evaluation of the bone change, and consequently start early intervention and treatment is an important topic. Magnetic resonance spectroscopy (MRS) has been successfully used in the evaluations of central nervous system, breast and prostate, etc. Evaluation of bone changes with MRS is under studied. This article reviewed the MRS in evaluation of vertebral body bone changes in patients with chronic renal failure. (authors)

  9. Recent progress in the performances of ultrastable quartz resonators and oscillators

    Directory of Open Access Journals (Sweden)

    Salzenstein Patrice

    2016-01-01

    Full Text Available Stressed compensated (SC cut led recently to the best frequency stability ever obtained with a quartz oscillator, 2.5 × 10−14 for the flicker frequency modulation (FFM floor. This result is confirmed in this paper with a 3.2 × 10−14 ± 1.1 × 10−14. The quartz resonator is integrated in a 5 MHz enhanced aging box double oven controlled oscillator. After reminding a bit of history, this paper describes how the first significant development in terms of ultra-stable quartz state-of-the-art oscillators was performed in the last 20 years, how the resonators were chosen, and main information about the development of adequate electronics and how to mechanically and thermally stabilized such an ultra-stable oscillator. We also present how to characterize the expected performances, and hot topics in quartz based oscillators.

  10. Image Guidance

    Science.gov (United States)

    Guidance that explains the process for getting images approved in One EPA Web microsites and resource directories. includes an appendix that shows examples of what makes some images better than others, how some images convey meaning more than others

  11. [Research progress of functional magnetic resonance imaging in mechanism studies of tinnitus].

    Science.gov (United States)

    Ji, B B; Li, M; Zhang, J N

    2018-02-07

    Tinnitus is a subjective symptom of phantom sound in the ear or brain without sound or electrical stimulation in the environment. The mechanism of tinnitus is complicated and mostly unclear. Recent studies suggested that the abnormal peripheral auditory input lead to neuroplasticity changes in central nervous system followed by tinnitus. More research concerned on the tinnitus central mechanism. A rapid development of functional magnetic resonance imaging (fMRI) technique made it more widely used in tinnitus central mechanism research. fMRI brought new findings but also presented some shortages in technology and cognition in tinnitus study. This article summarized the outcomes of fMRI research on tinnitus in recent years, exploring its existing problems and application prospects.

  12. Microwave-optical double resonance spectroscopy. Progress report, February 1, 1976--January 31, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, D.W.

    1976-11-01

    Zero-field and high-field optical detection of magnetic resonance (ODMR), electron paramagnetic resonance (EPR), and optical spectroscopy experiments have been performed on several systems in order to further basic knowledge of the structure, reactions, and response to radiation of atoms, molecules, and ions in their ground and/or excited electronic states. Particularly noteworthy results for the present contract year include the determination of the complete magnetic and optical properties of the lowest triplet states of 1-chloro, 1-bromo, and 1-iodonaphthalene, the development of a microscopic model for the intramolecular heavy-atom effect in the /sup 3/(..pi..,..pi..*) states of aromatic molecules, a detailed analysis of the angular dependence of the hyperfine and quadrupole structure in triplet 1-bromonaphthalene, observation of proton hyperfine structure in the hf ODMR spectra of short-lived triplet states, a definitive paper on the relative importance of spin delocalization and second-order spin-orbit coupling effects in /sup 3/(n,..pi..*) benzophenone (a phototype photochemical system), a detailed analysis of the level-anticrossing spectra of several triplet state benzophenones which exhibit hyperfine structure in the cross-relaxation region (thus permitting the determination of key magnetic parameters in the complete absence of perturbing microwave or radiofrequency fields), optical detection of ground-state NQR transitions in host crystal molecules, the observation of strong radiofrequency transitions near avoided crossing points in Zeeman energy level diagrams of photoexcited triplet states, the construction of zero-field ODMR, ODENDOR, and hf ODENDOR spectrometers, measurements of the activation parameters for ring interconversions of several free radicals containing five- and six-membered rings, and experimental proof that the triplet state of trimethylenemethane (a key reactive intermediate in organic chemistry) is the ground state.

  13. Classification of thyroid nodules using a resonance-frequency-based electrical impedance spectroscopy: progress assessment

    Science.gov (United States)

    Zheng, Bin; Tublin, Mitchell E.; Lederman, Dror; Klym, Amy H.; Brown, Erica D.; Gur, David

    2012-02-01

    The incidence of thyroid cancer is rising faster than other malignancies and has nearly doubled in the United States (U.S.) in the last 30 years. However, classifying between malignant and benign thyroid nodules is often difficult. Although ultrasound guided Fine Needle Aspiration Biopsy (FNAB) is considered an excellent tool for triaging patients, up to 25% of FNABs are inconclusive. As a result, definitive diagnosis requires an exploratory surgery and a large number of these are performed in the U.S. annually. It would be extremely beneficial to develop a non-invasive tool or procedure that could assist in assessing the likelihood of malignancy of otherwise indeterminate thyroid nodules, thereby reducing the number of exploratory thyroidectomies that are performed under general anesthesia. In this preliminary study we demonstrate a unique hand-held Resonance-frequency based Electrical Impedance Spectroscopy (REIS) device with six pairs of detection probes to detect and classify thyroid nodules using multi-channel EIS output signal sweeps. Under an Institutional Review Board (IRB)-approved case collection protocol, this REIS device is being tested in our clinical facility and we have been collecting an initial patient data set since March of this year. Between March and August of 2011, 65 EIS tests were conducted on 65 patients. Among these cases, six depicted pathology-verified malignant cells. Our initial assessment indicates the feasibility of easily applying this REIS device and measurement approach in a very busy clinical setting. The measured resonance frequency differences between malignant and benign nodules could potentially make it possible to accurately classify indeterminate thyroid nodules.

  14. Magnetic resonance imaging of the wrist in rheumatoid arthritis: demonstration of progression between 1 and 6 years

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Neal R. [Auckland Hospital, Department of Radiology, Private Bag 92024, Auckland (New Zealand); Auckland Radiology Group, Auckland (New Zealand); Crabbe, Jeffrey P. [Auckland Radiology Group, Auckland (New Zealand); McQueen, Fiona M. [Auckland Hospital, Department of Rheumatology, Auckland (New Zealand)

    2004-12-01

    To describe the changes seen in the wrist in rheumatoid arthritis (RA) on magnetic resonance (MR) imaging obtained at 1 year and 6 years. A cohort of patients with RA has been studied prospectively from symptom onset. MR scans of the dominant wrist in 31 patients obtained at 1 year and 6 years were compared for bone erosions, marrow signal change (oedema), synovial thickness and tenosynovitis. Twenty-two patients had an increase in erosion score in the interval and three patients showed a decrease in erosion score suggesting erosion healing. Fourteen patients had an increase in oedema score in the interval and eight patients had a decrease in oedema score. Synovial thickness increased in 13 patients and decreased in eight. Tenosynovitis increased in 15 patients and decreased in five. Bone erosions developed immediately adjacent to the tenosynovitis in two patients. MR imaging is useful in following the progress of bone erosions, marrow oedema, synovitis and tenosynovitis in RA. (orig.)

  15. Magnetic resonance imaging of the wrist in rheumatoid arthritis: demonstration of progression between 1 and 6 years

    International Nuclear Information System (INIS)

    Stewart, Neal R.; Crabbe, Jeffrey P.; McQueen, Fiona M.

    2004-01-01

    To describe the changes seen in the wrist in rheumatoid arthritis (RA) on magnetic resonance (MR) imaging obtained at 1 year and 6 years. A cohort of patients with RA has been studied prospectively from symptom onset. MR scans of the dominant wrist in 31 patients obtained at 1 year and 6 years were compared for bone erosions, marrow signal change (oedema), synovial thickness and tenosynovitis. Twenty-two patients had an increase in erosion score in the interval and three patients showed a decrease in erosion score suggesting erosion healing. Fourteen patients had an increase in oedema score in the interval and eight patients had a decrease in oedema score. Synovial thickness increased in 13 patients and decreased in eight. Tenosynovitis increased in 15 patients and decreased in five. Bone erosions developed immediately adjacent to the tenosynovitis in two patients. MR imaging is useful in following the progress of bone erosions, marrow oedema, synovitis and tenosynovitis in RA. (orig.)

  16. Assessing Mild Cognitive Impairment Progression using a Spherical Brain Mapping of Magnetic Resonance Imaging.

    Science.gov (United States)

    Martinez-Murcia, Francisco Jesus; Górriz, Juan Manuel; Ramírez, Javier; Segovia, Fermín; Salas-Gonzalez, Diego; Castillo-Barnes, Diego; Ortiz, Andrés

    2018-04-04

    The early diagnosis of Alzheimer's Disease (AD), particularly in its prodromal stage, mild cognitive impairment (MCI), still remains a challenge. Many computational tools have been developed to successfully explore and predict the disease progression. In this context, the Spherical Brain Mapping (SBM) proved its ability in detecting differences between AD and aged subjects without symptoms of dementia. Being a very visual tool, its application in predicting MCI conversion to AD could be of great help to understand neurodegeneration and the disease progression. In this work, we aim at predicting the conversion of MCI affected subjects to AD more than 6 months in advance of their conversion session and understanding the progression of the disease by predicting neuropsychological test outcomes from MRI data. In order to do so, SBM is applied to a series of MRI scans from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The resulting spherical brain maps show statistical and morphological information of the brain in a bidimensional plane, performing at the same time a significant feature reduction that provides a feature vector used in classification analysis. The study achieves up to 92.3% accuracy in the AD versus normal controls (CTL) detection, and up to a 77.6% in detection a of MCI conversions when trained with AD and CTL subjects. The prediction of neuropsychological test outcomes achieved R2 rates up to more than 0.5. Significant regions according to t-test and correlation analysis match reported brain areas in the literature. The results prove that Spherical Brain Mapping offers good ability to predict conversion patterns and cognitive state, at the same time that provides an additional aid for visualizing a two-dimensional abstraction map of the brain.

  17. Development of patient-controlled respiratory gating system based on visual guidance for magnetic-resonance image-guided radiation therapy.

    Science.gov (United States)

    Kim, Jung-In; Lee, Hanyoung; Wu, Hong-Gyun; Chie, Eui Kyu; Kang, Hyun-Cheol; Park, Jong Min

    2017-09-01

    The aim of this study is to develop a visual guidance patient-controlled (VG-PC) respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy (MR-IGRT) and to evaluate the performance of the developed system. The near-real-time cine planar MR image of a patient acquired during treatment was transmitted to a beam projector in the treatment room through an optical fiber cable. The beam projector projected the cine MR images inside the bore of the ViewRay system in order to be visible to a patient during treatment. With this visual information, patients voluntarily controlled their respiration to put the target volume into the gating boundary (gating window). The effect of the presence of the beam projector in the treatment room on the image quality of the MRI was investigated by evaluating the signal-to-noise ratio (SNR), uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity with the VG-PC gating system. To evaluate the performance of the developed system, we applied the VG-PC gating system to a total of seven patients; six patients received stereotactic ablative radiotherapy (SABR) and one patient received conventional fractionated radiation therapy. The projected cine MR images were visible even when the room light was on. No image data loss or additional time delay during delivery of image data were observed. Every indicator representing MRI quality, including SNR, uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity exhibited values higher than the tolerance levels of the manufacturer with the VG-PC gating system; therefore, the presence of the VG-PC gating system in the treatment room did not degrade the MR image quality. The average beam-off times due to respiratory gating with and without the VG-PC gating system were 830.3 ± 278.2 s and 1264.2 ± 302.1 s respectively (P = 0.005). Consequently, the total treatment times excluding

  18. Progression and variation of fatty infiltration of the thigh muscles in Duchenne muscular dystrophy, a muscle magnetic resonance imaging study.

    Science.gov (United States)

    Li, Wenzhu; Zheng, Yiming; Zhang, Wei; Wang, Zhaoxia; Xiao, Jiangxi; Yuan, Yun

    2015-05-01

    The purpose of this study was to assess the progression and variation of fatty infiltration of the thigh muscles of Duchenne muscular dystrophy patients. Muscle magnetic resonance imaging was used to measure the degree of fatty infiltration of the thigh muscles of 171 boys with Duchenne muscular dystrophy (mean age, 6.09 ± 2.30 years). Fatty infiltration was assigned using a modified Mercuri's scale 0-5 (normal-severe). The gluteus maximus and adductor magnus were affected in patients less than two years old, followed by the biceps femoris. Quadriceps and semimembranosus were first affected at the age of five to six years; the sartorius, gracilis and adductor longus remained apparently unaffected until seven years of age. Fatty infiltration of all the thigh muscles developed rapidly after seven years of age. The standard deviation of the fatty infiltration scores ranged from 2.41 to 4.87 before five years old, and from 6.84 to 11.66 between six and ten years old. This study provides evidence of highly variable degrees of fatty infiltration in children of different ages with Duchenne muscular dystrophy, and indicates that fatty infiltration progresses more quickly after seven years of age. These findings may be beneficial for the selection of therapeutic regimens and the analysis of future clinical trials. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Differential diagnosis of hepatocellular carcinoma and cavernous hemangioma. Possibility of progress evaluated by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Furui, Sigeru; Ohtomo, Kuni; Yamauchi, Tadasuke; Itai, Yuji; Iio, Masahiro

    1985-06-01

    In 35 cases of hepatocellular carcinoma (HCC) and 25 cases of cavernous hemangioma (CH) of the liver, magnetic resonance (MR) spin echo images were obtained using a 0.35 tesla superconducting MR imager (Siemens, Magnetom). On the images with a TR (repetition time) of 1600 msec and a TE (echo delay time) of 70 msec, all tumors appeared as high intensity areas, and there, Tumor/Liver intensity ratio (T/L) was calculated. T/sub 1/ (longitudinal relaxation time) and T/sub 2/ (transverse relaxation time) of the lesions were also calculated from the images with two TR (400 and 1600 msec) and two TE (35 and 70 msec). The T/sub 1/(940 +- 180 msec), T/sub 2/(110 +- 40 msec) and T/L(2.2 +- 0.4) of CH were significantly higher (p<0.001) than the T/sub 1/(660 +- 100 msec), T/sub 2/(60+-8 msec) and T/L(1.5 +- 0.4) of HCC, respectively. There was no correlation between these values and tumor size on MR, which ranged from 1.5 to 10 cm in diameter. All of CH satisfied the condition; T/sub 1/>660 msec, T/sub 2/>54 msec and T/L>1.6. In contrast, 73% of HCC did not satisfy the above condition. Our results suggest that use of MR will improve the accuracy of the differential diagnosis of HCC and CH.

  20. Magnetic resonance imaging with gadoxetic acid for local tumour progression after radiofrequency ablation in patients with hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Tae Wook; Rhim, Hyunchul; Lee, Jisun; Song, Kyoung Doo; Lee, Min Woo; Kim, Young-sun; Lim, Hyo Keun; Jang, Kyung Mi; Kim, Seong Hyun [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Gwak, Geum-Youn [Sungkyunkwan University School of Medicine, Division of Hepatology, Department of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Jung, Sin-Ho [Sungkyunkwan University School of Medicine, Biostatics and Clinical Epidemiology Center, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-10-15

    To develop and validate a prediction model using magnetic resonance imaging (MRI) for local tumour progression (LTP) after radiofrequency ablation (RFA) in hepatocellular carcinoma (HCC) patients. Two hundred and eleven patients who had received RFA as first-line treatment for HCC were retrospectively analyzed. They had undergone gadoxetic acid-enhanced MRI before treatment, and parameters including tumour size; margins; signal intensities on T1-, T2-, and diffusion-weighted images, and hepatobiliary phase images (HBPI); intratumoral fat or tumoral capsules; and peritumoural hypointensity in the HBPI were used to develop a prediction model for LTP after treatment. This model to discriminate low-risk from high-risk LTP groups was constructed based on Cox regression analysis. Our analyses produced the following model: 'risk score = 0.617 x tumour size + 0.965 x tumour margin + 0.867 x peritumoural hypointensity on HBPI'. This was able to predict which patients were at high risk for LTP after RFA (p < 0.001). Patients in the low-risk group had a significantly better 5-year LTP-free survival rate compared to the high-risk group (89.6 % vs. 65.1 %; hazard ratio, 3.60; p < 0.001). A predictive model based on MRI before RFA could robustly identify HCC patients at high risk for LTP after treatment. (orig.)

  1. Association of bone edema with the progression of bone erosions quantified by hand magnetic resonance imaging in patients with rheumatoid arthritis in remission.

    Science.gov (United States)

    Lisbona, Maria Pilar; Pàmies, Anna; Ares, Jesús; Almirall, Miriam; Navallas, Maria; Solano, Albert; Maymó, Joan

    2014-08-01

    To evaluate the association of synovitis, bone marrow edema (BME), and tenosynovitis in the progression of erosions quantified by hand magnetic resonance imaging (MRI) at 1 year in patients with early rheumatoid arthritis (RA) in remission. A total of 56 of 196 patients with early RA in remission at 1 year and with available MRI data at baseline and at 12 months were included. MRI images were assessed according to the Rheumatoid Arthritis Magnetic Resonance Imaging Scoring (RAMRIS) system. Persistent remission was defined as 28-joint Disease Activity Score-erythrocyte sedimentation rate ≤ 2.6 and/or Simplified Disease Activity Index ≤ 3.3 and/or the new boolean American College of Rheumatology/European League Against Rheumatism remission criteria for a continuous period of at least 6 months. Progression of bone erosions was defined as an increase of 1 or more units in annual RAMRIS score for erosions compared to baseline. At 1 year, the majority of patients with RA in sustained remission showed some inflammatory activity on MRI (94.6% synovitis, 46.4% BME, and 58.9% tenosynovitis) and 19 of the 56 patients (33.9%) showed MRI progression of bone erosions. A significant difference was observed in MRI BME at 1 year, with higher mean score in patients with progression compared to nonprogression of erosions (4.8 ± 5.6 and 1.4 ± 2.6, p = 0.03). Subclinical inflammation was identified by MRI in 96.4% of patients with RA in sustained clinical remission. Significantly higher scores of BME after sustained remission were observed in patients with progression of erosions compared to patients with no progression. The persistence of higher scores of BME may explain the progression of bone erosions in patients with persistent clinical remission.

  2. Repulsive guidance cue semaphorin 3A in urine predicts the progression of acute kidney injury in adult patients from a mixed intensive care unit.

    Science.gov (United States)

    Doi, Kent; Noiri, Eisei; Nangaku, Masaomi; Yahagi, Naoki; Jayakumar, Calpurnia; Ramesh, Ganesan

    2014-01-01

    Predicting the development of acute kidney injury (AKI) in the critical care setting is challenging. Although several biomarkers showed somewhat satisfactory performance for detecting established AKI even in a heterogeneous disease-oriented population, identification of new biomarkers that predict the development of AKI accurately is urgently required. A single-center prospective observational cohort study was undertaken to evaluate for the first time the reliability of the newly identified biomarker semaphorin 3A for AKI diagnosis in heterogeneous intensive care unit populations. In addition to five urinary biomarkers of L-type fatty acid-binding protein (L-FABP), neutrophil gelatinase-associated lipocalin (NGAL), IL-18, albumin and N-acetyl-β-d-glucosaminidase (NAG), urinary semaphorin 3A was measured at intensive care unit (ICU) admission. Three hundred thirty-nine critically ill adult patients were recruited for this study. Among them, 131 patients (39%) were diagnosed with AKI by the RIFLE criteria and 66 patients were diagnosed as AKI at post-ICU admission (later-onset AKI). Eighty-four AKI patients showed worsening severity during 1 week observation (AKI progression). Although L-FABP, NGAL and IL-18 showed significantly higher area under the curve (AUC)-receiver operating characteristic (ROC) values than semaphorin 3A in detecting established AKI, semaphorin 3A was able to detect later-onset AKI and AKI progression with similar AUC-ROC values compared with the other five biomarkers [AUC-ROC (95% CI) for established AKI 0.64 (0.56-0.71), later-onset AKI 0.71 (0.64-0.78), AKI progression 0.71 (0.64-0.77)]. Urinary semaphorin 3A was not increased in non-progressive established AKI, while the other biomarkers were elevated regardless of further progression. Finally, sepsis did not have any impact on semaphorin 3A while the other urinary biomarkers were increased with sepsis. Semaphorin 3A is a new biomarker of AKI which may have a distinct predictive use for

  3. Golimumab therapy-induced indicators of X-ray inflammation progression and magnitude according to magnetic resonance imaging evidence in patients with rheumatoid arthritis, ankylosing spondylitis, or psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Aleksandr Viktorovich Smirnov

    2013-01-01

    Full Text Available The paper gives data on the progression of X-ray and magnetic resonance imaging changes in the hand and foot joints of patients with rheumatoid arthritis and psoriatic arthropathy and in the axial skeleton of those with ankylosing spondylitis when golimumab is used. Golimumab therapy is shown to retard the progression of structural changes in the peripheral joints and vertebral column. There is a significant correlation between magnetic resonance imaging evidence and blood C-reactive protein concentrations.

  4. Radiographic progression is associated with resolution of systemic inflammation in patients with axial spondylarthritis treated with tumor necrosis factor α inhibitors: A study of radiographic progression, inflammation on magnetic resonance imaging, and circulating biomarkers of inflammation

    DEFF Research Database (Denmark)

    Pedersen, Susanne Juhl; Sørensen, Inge Juul; Lambert, Robert G W

    2011-01-01

    To investigate the relationship of circulating biomarkers of inflammation (C-reactive protein [CRP], interleukin-6 [IL-6], and YKL-40), angiogenesis (vascular endothelial growth factor), cartilage turnover (C-terminal crosslinking telopeptide of type II collagen [CTX-II], total aggrecan, matrix...... metalloproteinase 3 [MMP-3], and cartilage oligomeric matrix protein [COMP]), and bone turnover (CTX-I and osteocalcin) to inflammation on magnetic resonance imaging (MRI) and radiographic progression in patients with axial spondylarthritis (SpA) beginning tumor necrosis factor a (TNFa) inhibitor therapy....

  5. Surgical resection of low-grade gliomas in eloquent areas with the guidance of the preoperative functional magnetic resonance imaging and craniometric points

    Directory of Open Access Journals (Sweden)

    Ahmed Abdullah

    2016-01-01

    Full Text Available Objectives: Surgical resection of low-grade gliomas (LGGs in eloquent areas is one of the challenges in neurosurgery, using assistant tools to facilitate effective excision with minimal postoperative neurological deficits has been previously discussed (awake craniotomy and intraoperative cortical stimulation; however, these tools could have their own limitations thus implementation of a simple and effective technique that can guide to safe excision is needed in many situations. Materials and Methods: The authors conducted a retrospective analysis of a prospectively collected data of 76 consecutive surgical cases of LGGs of these 21 cases were situated in eloquent areas. Preoperative functional magnetic resonance imaging (fMRI, pre- and post-operative MRI with volumetric analysis of the tumor size was conducted, and intraoperative determination of the craniometric points related to the tumor (navigation guided in 10 cases were studied to evaluate the effectiveness of the aforementioned tools in safe excision of the aforementioned tumors. Results: Total-near total excision in 14 (66.67% subtotal in 6 (28.57%, and biopsy in 1 case (4.57%. In long-term follow–up, only one case experienced persistent dysphasia. Conclusion: In spite of its simplicity, the identification of the safe anatomical landmarks guided by the preoperative fMRI is a useful technique that serves in safe excision of LGGs in eloquent areas. Such technique can replace intraoperative evoked potentials or the awake craniotomy in most of the cases. However, navigation-guided excision might be crucial in deeply seated and large tumors to allow safe and radical excision.

  6. Suitability of a tumour-mimicking material for the evaluation of high-intensity focused ultrasound ablation under magnetic resonance guidance

    International Nuclear Information System (INIS)

    Pichardo, S; Kivinen, J; Curiel, L; Melodelima, D

    2013-01-01

    This study tests the suitability of a tumour-mimic for targeting magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU). An agarose-based tumour-mimic was injected as a warm solution that polymerized in tissue. Thermal characteristics and acoustic absorption of the mimic were observed within the values reported for tissues. The relaxation times at 3T were 1679 ± 15 ms for T1 and 41 ± 1 ms for T2. The mimic was clearly visible on in vivo images. With lower contrast the tumour-mimic was visible on T2-weighted images, where it was possible to detect the ablated tissue surrounding the mimic after sonications. HIFU sonications were performed to induce thermal ablation on and around the mimic using a Sonalleve system (Philips). MR thermometry maps were performed during HIFU. The average temperature when the sonication was done at the tumour-mimic was 67.6 ± 8.0 °C in vitro and 67.6 ± 5.0 °C in vivo. The average temperature for sonications at tissues was 68.4 ± 8.7 °C in vitro (liver) and 66.0 ± 2.6 °C in vivo (muscle), with no significant difference between tissue and tumour-mimic (p > 0.05). The tumour-mimic behaviour when using MR-guided HIFU was similar to tissues, showing that this mimic can be used as an alternative to tumour models for validating MR-guided HIFU devices targeting. (paper)

  7. Detection of long-term progression of myocardial fibrosis in Duchenne muscular dystrophy in an affected family: A cardiovascular magnetic resonance study

    International Nuclear Information System (INIS)

    Walcher, Thomas; Steinbach, Peter; Spiess, Jochen; Kunze, Markus; Gradinger, Robert; Walcher, Daniel; Bernhardt, Peter

    2011-01-01

    Background: Detection of myocardial fibrosis and left ventricular dysfunction in Duchenne muscular dystrophy (DMD) is the corner stone for further therapeutic studies. Little is known about the ability of cardiac magnetic resonance imaging (CMR) to evaluate progression of myocardial fibrosis. Aim of our study was to provide CMR data in a previously genotyped DMD family and to evaluate whether progression of myocardial fibrosis could be visualized. Methods and results: DMD genotypes were available in 14 family members. CMR was performed in 4/5 carrier females, in 2/2 affected males and in one healthy family member with normal genotype. Functional images and late gadolinium enhanced (LGE) images in contiguous short-axis orientation were acquired at baseline and follow-up of 1231 days CMR examination could be repeated in three carrier females, in one affected male and in the healthy subject previously scanned. Mean decrease of left ventricular ejection fraction during the follow-up period was 10.5 ± 11.0%, mean progression of LGE volume 11.7 ± 9.5%. Conclusions: Myocardial fibrosis seems to occur prior to global left ventricular dysfunction in DMD diseased males and carrier females. CMR could be used to evaluate progression of myocardial fibrosis and left ventricular function and may thus serve as an important diagnostic tool in the evaluation of therapeutical options in DMD.

  8. Detection of long-term progression of myocardial fibrosis in Duchenne muscular dystrophy in an affected family: A cardiovascular magnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Walcher, Thomas [Department of Internal Medicine II, University of Ulm, Ulm (Germany); Steinbach, Peter [Institute of Human Genetics, University of Ulm, Ulm (Germany); Spiess, Jochen; Kunze, Markus; Gradinger, Robert; Walcher, Daniel [Department of Internal Medicine II, University of Ulm, Ulm (Germany); Bernhardt, Peter, E-mail: peter.bernhardt@uniklinik-ulm.de [Department of Internal Medicine II, University of Ulm, Ulm (Germany)

    2011-10-15

    Background: Detection of myocardial fibrosis and left ventricular dysfunction in Duchenne muscular dystrophy (DMD) is the corner stone for further therapeutic studies. Little is known about the ability of cardiac magnetic resonance imaging (CMR) to evaluate progression of myocardial fibrosis. Aim of our study was to provide CMR data in a previously genotyped DMD family and to evaluate whether progression of myocardial fibrosis could be visualized. Methods and results: DMD genotypes were available in 14 family members. CMR was performed in 4/5 carrier females, in 2/2 affected males and in one healthy family member with normal genotype. Functional images and late gadolinium enhanced (LGE) images in contiguous short-axis orientation were acquired at baseline and follow-up of 1231 days CMR examination could be repeated in three carrier females, in one affected male and in the healthy subject previously scanned. Mean decrease of left ventricular ejection fraction during the follow-up period was 10.5 {+-} 11.0%, mean progression of LGE volume 11.7 {+-} 9.5%. Conclusions: Myocardial fibrosis seems to occur prior to global left ventricular dysfunction in DMD diseased males and carrier females. CMR could be used to evaluate progression of myocardial fibrosis and left ventricular function and may thus serve as an important diagnostic tool in the evaluation of therapeutical options in DMD.

  9. Diagnosis and treatment of progressive space-occupying radiation necrosis following stereotactic radiosurgery for brain metastasis: value of proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Kimura, T.; Sako, K.; Tohyama, Y.; Aizawa, S.; Tanaka, T.; Yoshida, H.; Aburano, T.; Tanaka, K.

    2003-01-01

    There have been some reports that radiation necrosis can be controlled conservatively. There are rare cases showing progressive space-occupying radiation necrosis (PSORN). It is very difficult to control PSORN by conservative treatment. The purpose of this study was to evaluate the early diagnosis of these cases and the timing of surgery for patients with PSORN. We have experienced some cases where quality of life was improved by the removal of PSORN after stereotactic radiosurgery (SRS) for brain metastases. Therefore, we evaluated retrospectively the diagnosis and treatment of six cases of symptomatic PSORN at approximately 6-12 months after SRS for metastatic brain tumours. In all six cases, on Magnetic Resonance Imaging with Gd contrast material (Gd-MRI), PSORN was revealed as a ring-like enhanced mass with large perifocal oedema coupled with the appearance of neurological deficit. Proton Magnetic Resonance Spectroscopy ( 1 H-MRS) enabled us to differentiate PSORN from recurrence of metastases in all six cases. Single Photon Emission Computed Tomography with thallium-201 chloride ( 201 TICI-SPECT) enabled us to do this in four cases of the six. In four cases of the six, lesionectomy of the ring-like enhanced mass (PSORN) was performed, und in two of these cases the removal was performed within 4 weeks from the time when conservative treatment became ineffective, and the neurological deficit and perifocal oedema was improved as was the quality of life. However, in the other two patients who were left for more than 16 weeks, the deficit was gradually progressive. The two patients who did not receive lesionectomy were treated by conservative means with steroids and/or heparin and warfarin and they had progressive neurological symptoms. Although, the number of patients is small in this study, and more data will be needed, it is recommended that lesionectomy is performed at an early stage, if possible, when conservative management has failed. (author)

  10. Research progress of functional magnetic resonance imaging in cross-modal activation of visual cortex during tactile perception

    International Nuclear Information System (INIS)

    Zhan Jie; Gong Honghan

    2013-01-01

    An increasing amount of neuroimaging studies recently demonstrated activation of visual cortex in both blind and sighted participants when performing a variety of tactile tasks such as Braille reading and tactile object recognition, which indicates that visual cortex not only receives visual information, but may participate in tactile perception. To address these cross-modal changes of visual cortex and the neurophysiological mechanisms, many researchers conducted explosive studies using functional magnetic resonance imaging (fMRI) and have made some achievements. This review focuses on cross-modal activation of visual cortex and the underlying mechanisms during tactile perception in both blind and sighted individuals. (authors)

  11. Electron spin resonance studies of radiation effects. Final report, 1964-1979 (including annual progress reports for 1978 and 1979)

    International Nuclear Information System (INIS)

    Rogers, M.T.

    1979-07-01

    The discovery of new free radicals, largely in irradiated single crystals of nonmetallic solids, and the determination of the molecular and electronic structures of these paramagnetic species by electron spin resonance (ESR) spectroscopy, have been carried out using a wide variety of organic and inorganic materials. The mechanisms of production of radicals in solids, their motions, and their reactions have been investigated and some applicable general principles deduced. Emphasis has been on aliphatic free radicals from irradiated carboxylic acids and amides and their halogen-substituted derivatives, organometallic radicals and substituted cyclic hydrocarbon radicals; inorganic radicals studied include V centers, hypervalent radicals and electron adducts. Extensive investigations of paramagnetic transition metal complexes, particularly cyanides and fluorides, have been made. In all cases quantum mechanical calculations have been employed as far as possible in interpreting the data. An improved method for analyzing experimental ESR spectra of single crystals has been developed and a number of crystal structures have been determined to supplement the ESR studies. Applications of nuclear quadrupole resonance spectroscopy to the study of structure and bonding in inorganic solids have been made and a method for using nuclear magnetic relaxation data for estimating quadrupole coupling constants in liquids has been developed

  12. Combined high-field intraoperative magnetic resonance imaging and endoscopy increase extent of resection and progression-free survival for pituitary adenomas

    Science.gov (United States)

    Sylvester, Peter T.; Evans, John A.; Zipfel, Gregory J.; Chole, Richard A.; Uppaluri, Ravindra; Haughey, Bruce H.; Getz, Anne E.; Silverstein, Julie; Rich, Keith M.; Kim, Albert H.; Dacey, Ralph G.

    2014-01-01

    Purpose The clinical benefit of combined intraoperative magnetic resonance imaging (iMRI) and endoscopy for transsphenoidal pituitary adenoma resection has not been completely characterized. This study assessed the impact of microscopy, endoscopy, and/or iMRI on progression-free survival, extent of resection status (gross-, near-, and subtotal resection), and operative complications. Methods Retrospective analyses were performed on 446 transsphenoidal pituitary adenoma surgeries at a single institution between 1998 and 2012. Multivariate analyses were used to control for baseline characteristics, differences during extent of resection status, and progression-free survival analysis. Results Additional surgery was performed after iMRI in 56/156 cases (35.9 %), which led to increased extent of resection status in 15/156 cases (9.6 %). Multivariate ordinal logistic regression revealed no increase in extent of resection status following iMRI or endoscopy alone; however, combining these modalities increased extent of resection status (odds ratio 2.05, 95 % CI 1.21–3.46) compared to conventional transsphenoidal microsurgery. Multivariate Cox regression revealed that reduced extent of resection status shortened progression-free survival for near- versus gross-total resection [hazard ratio (HR) 2.87, 95 % CI 1.24–6.65] and sub- versus near-total resection (HR 2.10; 95 % CI 1.00–4.40). Complication comparisons between microscopy, endoscopy, and iMRI revealed increased perioperative deaths for endoscopy versus microscopy (4/209 and 0/237, respectively), but this difference was non-significant considering multiple post hoc comparisons (Fisher exact, p = 0.24). Conclusions Combined use of endoscopy and iMRI increased pituitary adenoma extent of resection status compared to conventional transsphenoidal microsurgery, and increased extent of resection status was associated with longer progression-free survival. Treatment modality combination did not significantly impact

  13. Graphic Turbulence Guidance

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Forecast turbulence hazards identified by the Graphical Turbulence Guidance algorithm. The Graphical Turbulence Guidance product depicts mid-level and upper-level...

  14. Graphical Turbulence Guidance - Composite

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Forecast turbulence hazards identified by the Graphical Turbulence Guidance algorithm. The Graphical Turbulence Guidance product depicts mid-level and upper-level...

  15. Career guidance in communities

    DEFF Research Database (Denmark)

    Thomsen, Rie

    for the development of a critically reflexive career guidance practice. The considerations are organised around seven elements. 1. Creating opportunity, structure and access 2. Entering a community and increasing visibility 3. Providing guidance in communities 4. Exploring potentials in guidance situations 5...... in career guidance practices as well as in the lives of the people in the communities. This paper falls into two parts: The first part considers the collective as the starting point for the development of meaningful career guidance activities. Based on previous research on career guidance in communities......The aim of this paper is to inspire practitioners and professionals to leave their offices to bring career guidance into communities that might not identify with career guidance in the first instance. By making the effort to engage with communities, practitioners may bring about a critical change...

  16. A Punctate Magnetic Resonance Imaging Pattern in a Patient with Systemic Lupus Erythematosus is an Early Sign of Progressive Multifocal Leukoencephalopathy: A Clinicopathological Study.

    Science.gov (United States)

    Ishii, Junko; Shishido-Hara, Yukiko; Kawamoto, Michi; Fujiwara, Satoru; Imai, Yukihiro; Nakamichi, Kazuo; Kohara, Nobuo

    2018-04-27

    A 37-year-old woman with systemic lupus erythematosus (SLE) presented with gait disturbance and cognitive dysfunction. Brain magnetic resonance imaging (MRI) revealed small, punctate, T2-/fluid-attenuated inversion recovery-hyperintense and T1-hypointense lesions without gadolinium enhancement, which is atypical for progressive multifocal leukoencephalopathy (PML). On a pathological examination of biopsied brain tissues, JC virus-infected cells were hardly detected via immunohistochemistry but were certainly detected via in situ hybridization, conclusively verifying the PML diagnosis. After tapering off the immunosuppressant and mefloquine administration, the MRI findings revealed gradual improvement, and she has been stable for over 18 months. A punctate MRI pattern is not specific to natalizumab-associated PML but may be a ubiquitous early sign useful for the early diagnosis of PML.

  17. Effects of Liver Fibrosis Progression on Tissue Relaxation Times in Different Mouse Models Assessed by Ultrahigh Field Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Andreas Müller

    2017-01-01

    Full Text Available Recently, clinical studies demonstrated that magnetic resonance relaxometry with determination of relaxation times T1 and T2⁎ may aid in staging and management of liver fibrosis in patients suffering from viral hepatitis and steatohepatitis. In the present study we investigated T1 and T2⁎ in different models of liver fibrosis to compare alternate pathophysiologies in their effects on relaxation times and to further develop noninvasive quantification methods of liver fibrosis. MRI was performed with a fast spin echo sequence for measurement of T1 and a multigradient echo sequence for determination of T2⁎. Toxic liver fibrosis was induced by injections of carbon tetrachloride (1.4 mL CCl4 per kg bodyweight and week, for 3 or 6 weeks in BALB/cJ mice. Chronic sclerosing cholangitis was mimicked using the ATP-binding cassette transporter B4 knockout (Abcb4 -/- mouse model. Untreated BALB/cJ mice served as controls. To assess hepatic fibrosis, we ascertained collagen contents and fibrosis scores after Sirius red staining. T1 and T2⁎ correlate differently to disease severity and etiology of liver fibrosis. T2⁎ shows significant decrease correlating with fibrosis in CCl4 treated animals, while demonstrating significant increase with disease severity in Abcb4 -/- mice. Measurements of T1 and T2⁎ may therefore facilitate discrimination between different stages and causes of liver fibrosis.

  18. Magnetic resonance imaging can accurately assess the long-term progression of knee structural changes in experimental dog osteoarthritis.

    Science.gov (United States)

    Boileau, C; Martel-Pelletier, J; Abram, F; Raynauld, J-P; Troncy, E; D'Anjou, M-A; Moreau, M; Pelletier, J-P

    2008-07-01

    Osteoarthritis (OA) structural changes take place over decades in humans. MRI can provide precise and reliable information on the joint structure and changes over time. In this study, we investigated the reliability of quantitative MRI in assessing knee OA structural changes in the experimental anterior cruciate ligament (ACL) dog model of OA. OA was surgically induced by transection of the ACL of the right knee in five dogs. High resolution three dimensional MRI using a 1.5 T magnet was performed at baseline, 4, 8 and 26 weeks post surgery. Cartilage volume/thickness, cartilage defects, trochlear osteophyte formation and subchondral bone lesion (hypersignal) were assessed on MRI images. Animals were killed 26 weeks post surgery and macroscopic evaluation was performed. There was a progressive and significant increase over time in the loss of knee cartilage volume, the cartilage defect and subchondral bone hypersignal. The trochlear osteophyte size also progressed over time. The greatest cartilage loss at 26 weeks was found on the tibial plateaus and in the medial compartment. There was a highly significant correlation between total knee cartilage volume loss or defect and subchondral bone hypersignal, and also a good correlation between the macroscopic and the MRI findings. This study demonstrated that MRI is a useful technology to provide a non-invasive and reliable assessment of the joint structural changes during the development of OA in the ACL dog model. The combination of this OA model with MRI evaluation provides a promising tool for the evaluation of new disease-modifying osteoarthritis drugs (DMOADs).

  19. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression. A study with quantitative magnetic resonance spectroscopy at 3 Tesla.

    Science.gov (United States)

    Aboul-Enein, Fahmy; Krssák, Martin; Höftberger, Romana; Prayer, Daniela; Kristoferitsch, Wolfgang

    2010-07-20

    Reduced N-acetyl-aspartate (NAA) levels in magnetic resonance spectroscopy (MRS) may visualize axonal damage even in the normal appearing white matter (NAWM). Demyelination and axonal degeneration are a hallmark in multiple sclerosis (MS). To define the extent of axonal degeneration in the NAWM in the remote from focal lesions in patients with relapsing-remitting (RRMS) and secondary progressive MS (SPMS). 37 patients with clinical definite MS (27 with RRMS, 10 with SPMS) and 8 controls were included. We used 2D (1)H-MR-chemical shift imaging (TR = 1500ms, TE = 135ms, nominal resolution 1ccm) operating at 3Tesla to assess the metabolic pattern in the fronto-parietal NAWM. Ratios of NAA to creatine (Cr) and choline (Cho) and absolute concentrations of the metabolites in the NAWM were measured in each voxel matching exclusively white matter on the anatomical T2 weighted MR images. No significant difference of absolute concentrations for NAA, Cr and Cho or metabolite ratios were found between RRMS and controls. In SPMS, the NAA/Cr ratio and absolute concentrations for NAA and Cr were significantly reduced compared to RRMS and to controls. In our study SPMS patients, but not RRMS patients were characterized by low NAA levels. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression.

  20. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  1. Usefulness of the computed tomography and magnetic resonance in evaluation of progress of treatment of the neoplasmatic diseases in children

    International Nuclear Information System (INIS)

    Myga-Porosiło, Jolanta; Borowiak, Hanna; Sraga, Wojciech; Jackowska, Zuzanna; Serafin, Magdalena; Kluczewska, Ewa

    2012-01-01

    Neoplastmatic diseases constitute about 1% diseases in children in Poland, what makes about 1200 new incidents during one year. Fast diagnosis in those illnesses is crucial in treatment results. The point of this work was to value usefulness of CT and MRI in diagnostics of neoplasmatic diseases in children. The retrospective study involved 121 children examined in CT and MRI because of suspicion or during treatment of neoplasmatic disease. Together 184 CT and 119 MRI examination were performed. Eventually in 106 children neoplasmatic disease was diagnosed. In 16 cases neoplasm was excluded. In the analyzed group of patients acute lymphoblastic and non lymphoblastic leukemia was diagnosed in 68 children (55.7%); among them mycosis was identified after radiological examinations in 7 cases (10.3%). 8 children (6.6%) with non Hodgkin lymphoma and 11 (9%) with Hodgkin lymphoma were examined. Nephroblastoma was found after MRI and CT in 6 cases (4.9%). Presence of tumors, that were classified histopatologically as PNET, was confirmed in 4 children. In 15 cases after MRI and CT neoplasmatic disease was excluded. Depending on the kind of sickness MRI and CT may fulfill basic or subsidiary role in diagnostic and estimating the progress of treatment in neoplasmatic diseases among children

  2. Magnetic resonance imaging-determined synovial membrane volume as a marker of disease activity and a predictor of progressive joint destruction in the wrists of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Hansen, M; Stoltenberg, M

    1999-01-01

    OBJECTIVE: To evaluate the synovial membrane volume, determined by magnetic resonance imaging (MRI), as a marker of joint disease activity and a predictor of progressive joint destruction in rheumatoid arthritis (RA). METHODS: Twenty-six patients with RA, randomized to receive disease-modifying a......OBJECTIVE: To evaluate the synovial membrane volume, determined by magnetic resonance imaging (MRI), as a marker of joint disease activity and a predictor of progressive joint destruction in rheumatoid arthritis (RA). METHODS: Twenty-six patients with RA, randomized to receive disease......-Pratt analysis). The rate of erosive progression on MRI was highly correlated with baseline scores and, particularly, with area under the curve (AUC) values of synovial membrane volume (Spearman's sigma = 0.69, P

  3. A prominent lactate peak as a potential key magnetic resonance spectroscopy (MRS feature of progressive multifocal leukoencephalopathy (PML: Spectrum pattern observed in three patients

    Directory of Open Access Journals (Sweden)

    Duško Kozić

    2017-11-01

    Full Text Available Progressive multifocal leukoencephalopathy (PML is a rare, often fatal, opportunistic infection, associated with demyelinating process. PML is caused by John Cunningham (JC polyomavirus, and predominantly affects patients with human immunodeficiency virus (HIV infection or other immunocompromised patients. The purpose of this study was to determine the role of magnetic resonance spectroscopy (MRS in establishing the diagnosis of PML. MRS with long and short echo time was performed in two patients with PML associated with HIV infection and in one PML patient associated with chronic lymphocytic leukemia. The most prominent peak on the obtained spectra was for lactate; it showed 2-3 times higher concentration of lactate compared to choline, almost 4-6 times higher lactate concentration compared to creatine, and 4-11 times higher lactate in comparison to N-acetylaspartate concentration. Similar spectrum pattern was observed in all patients. To the best of our knowledge, this is a new finding that might be useful in early diagnosis of PML. Nevertheless, further confirmation of our results is needed, since we analyzed the spectrum pattern only in three patients. Overall, our results could help in early detection of PML, especially in non-HIV patients, and thus prevent the fatal outcome of the disease. MRS could also be useful in detecting “tumefactive” demyelinating lesions in PML patients, associated with immune reconstitution inflammatory syndrome, to avoid misdiagnosis of neoplasm.

  4. The history and future of dietary guidance in America

    Science.gov (United States)

    Evidence-based dietary guidance in the US has progressed substantially since its inception over 100 years ago. This review describes the historical development and significance of dietary guidance in the US, including the Dietary Guidelines for Americans, and emphasizes the foundations upon which th...

  5. Ecological Restoration: Guidance from Theory

    Directory of Open Access Journals (Sweden)

    Joy Zedler

    2005-09-01

    Full Text Available A review of the science and practice of ecosystem restoration led me to identify key ecological theories and concepts that are relevant to planning, implementing, and sustaining restoration efforts. From experience with actual restoration projects, I provide guidance for improving the restoration process. Despite an abundance of theory and guidance, restoration goals are not always achieved, and pathways toward targets are not highly predictable. This is understandable, since each restoration project has many constraints and unique challenges. To improve restoration progress, I advise that sites be designed as experiments to allow learning while doing. At least the larger projects can be restored in phases, each designed as experimental treatments to test alternative restoration approaches. Subsequent phases can then adopt one or more of the treatments that best achieved goals in earlier phases while applying new tests of other restoration measures. Both science and restoration can progress simultaneously. This phased, experimental approach (called “adaptive restoration” is an effective tool for improving restoration when monitoring, assessment, interpretation and research are integrated into the process.

  6. Role of magnetic resonance planimetry and magnetic resonance parkinsonism index in discriminating Parkinson’s disease and progressive supranuclear palsy: a retrospective study based on 1.5 and 3 T MRI

    Directory of Open Access Journals (Sweden)

    Nizamani WM

    2017-10-01

    Full Text Available Waseem Mehmood Nizamani,1 Fatima Mubarak,1 Muhammad Danish Barakzai,1 Muhammad Saad Ahmed2 1Department of Radiology, Aga Khan University Hospital, Karachi, Pakistan, 2Department of Radiology, Ziauddin University Hospital, Karachi, Pakistan Objective: The objective of the study was to assess magnetic resonance (MR planimetric measurements and MR parkinsonism index (MRPI in differentiating progressive supranuclear palsy (PSP from Parkinson’s disease (PD using 1.5 and 3 T MRI scanner. Subjects and methods: After ethical approval was obtained, analysis of 34 consecutive patients with PSP, 34 patients with PD and 34 healthy controls (HCs was performed. HCs were age-matched adults without any history of neurodegenerative disease or movement disorders. Retrospective data from the past 10 years (from January 2006 to December 2015 were obtained from the Hospital Information Management System, and informed consent was obtained from all participants. The measurements of pons area–midbrain area ratio (P/M and MCP width–superior cerebellar peduncle (SCP width ratio (MCP/SCP were used, and MRPI was calculated by the formula ([P/M]×[MCP/SCP]. Results: Midbrain area and SCP width in patients with PSP (19 males, 15 females; mean age =66.7 years were significantly (P<0.001 smaller than in patients with PD (20 males, 14 females; mean age =66.7 years and control participants (17 males, 17 females; mean age =66.1 years. P/M and MCP/SCP were significantly higher in patients with PSP than in patients with PD and control participants. All measurements showed some overlap of values between patients with PSP and patients from PD group and control participants. MRPI value was significantly higher in patients with PSP (mean 21.00 than in patients with PD (mean 9.50; P<0.001 and control participants (mean 9.6; P<0.001, without any overlap of values among groups. No correlation was found between the duration of disease, PSP rating scale, PSP staging system and MRPI in

  7. Visual Evoked Potential and Magnetic Resonance Imaging are More Effective Markers of Multiple Sclerosis Progression than Laser Polarimetry with Variable Corneal Compensation.

    Science.gov (United States)

    Kantorová, Ema; Ziak, Peter; Kurča, Egon; Koyšová, Mária; Hladká, Mária; Zeleňák, Kamil; Michalik, Jozef

    2014-01-01

    The aim of our study was to assess the role of laser polarimetry and visual evoked potentials (VEP) as potential biomarkers of disease progression in multiple sclerosis (MS). A total of 41 patients with MS (82 eyes) and 22 age-related healthy volunteers (44 eyes) completed the study. MS patients were divided into two groups, one (ON) with a history of optic neuritis (17 patients, 34 eyes) and another group (NON) without it (24 patients, 48 eyes). The MS patients and controls underwent laser polarimetry (GDx) examination of the retinal nerve fiber layer (RNFL). In the MS group, we also examined: Kurtzke "expanded disability status scale" (EDSS), the duration of the disorder, VEP - latency and amplitude, and conventional brain magnetic resonance imaging (MRI). Our results were statistically analyzed using ANOVA, Mann-Whitney, and Spearman correlation analyses. In the MS group, brain atrophy and new T2 brain lesions in MRI correlated with both VEP latencies and amplitudes. Separate comparisons revealed VEP latency testing to be less sensitive in ON than in NON-patients. In ON patients, VEP amplitudes correlated mildly with brain atrophy (r = -0.15) and strongly with brain new MRI lesions (r = -0.8). In NON-patients, highly significant correlation of new MRI brain lesions with VEP latencies (r = 0.63, r = 0.6) and amplitudes (r = -0.3, r = -4.2) was found. EDSS also correlated with brain atrophy in this group (r = 0.5). Our study did not find a correlation of GDx measures with MRI tests. The GDx method was not able to detect whole brain demyelinization and the degeneration process, but was only able to reveal the involvement of optic nerves in ON and NON-patients. In our study, we found that both methods (VEP and GDx) can be used for the detection of optic nerve damage, but VEP was found to be superior in evaluating whole brain demyelinization and axonal degeneration. Both VEP and MRI, but not GDx, have an important role in monitoring

  8. Automatic total kidney volume measurement on follow-up magnetic resonance images to facilitate monitoring of autosomal dominant polycystic kidney disease progression.

    Science.gov (United States)

    Kline, Timothy L; Korfiatis, Panagiotis; Edwards, Marie E; Warner, Joshua D; Irazabal, Maria V; King, Bernard F; Torres, Vicente E; Erickson, Bradley J

    2016-02-01

    Renal imaging examinations provide high-resolution information about the anatomic structure of the kidneys and are used to measure total kidney volume (TKV) in autosomal dominant polycystic kidney disease (ADPKD) patients. TKV has become the gold-standard image biomarker for ADPKD progression at early stages of the disease and is used in clinical trials to characterize treatment efficacy. Automated methods to segment the kidneys and measure TKV are desirable because of the long time requirement for manual approaches such as stereology or planimetry tracings. However, ADPKD kidney segmentation is complicated by a number of factors, including irregular kidney shapes and variable tissue signal at the kidney borders. We describe an image processing approach that overcomes these problems by using a baseline segmentation initialization to provide automatic segmentation of follow-up scans obtained years apart. We validated our approach using 20 patients with complete baseline and follow-up T1-weighted magnetic resonance images. Both manual tracing and stereology were used to calculate TKV, with two observers performing manual tracings and one observer performing repeat tracings. Linear correlation and Bland-Altman analysis were performed to compare the different approaches. Our automated approach measured TKV at a level of accuracy (mean difference ± standard error = 0.99 ± 0.79%) on par with both intraobserver (0.77 ± 0.46%) and interobserver variability (1.34 ± 0.70%) of manual tracings. All approaches had excellent agreement and compared favorably with ground-truth manual tracing with interobserver, stereological and automated approaches having 95% confidence intervals ∼ ± 100 mL. Our method enables fast, cost-effective and reproducible quantification of ADPKD progression that will facilitate and lower the costs of clinical trials in ADPKD and other disorders requiring accurate, longitudinal kidney quantification. In addition, it will hasten the routine use of

  9. Optimal Aerocapture Guidance

    Data.gov (United States)

    National Aeronautics and Space Administration — The main goal of my research is to develop, implement, verify, and validate an optimal numerical predictor-corrector aerocapture guidance algorithm that is...

  10. Coral Reef Guidance

    Science.gov (United States)

    Guidance prepared by EPA and Army Corps of Engineers concerning coral reef protection under the Clean Water Act, Marine Protection, Research, and Sanctuaries Act, Rivers and Harbors Act, and Federal Project Authorities.

  11. Laser Guidance Analysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility, which provides for real time, closed loop evaluation of semi-active laser guidance hardware, has and continues to be instrumental in the development...

  12. Threshold guidance update

    International Nuclear Information System (INIS)

    Wickham, L.E.

    1986-01-01

    The Department of Energy (DOE) is developing the concept of threshold quantities for use in determining which waste materials must be handled as radioactive waste and which may be disposed of as nonradioactive waste at its sites. Waste above this concentration level would be managed as radioactive or mixed waste (if hazardous chemicals are present); waste below this level would be handled as sanitary waste. Last years' activities (1984) included the development of a threshold guidance dose, the development of threshold concentrations corresponding to the guidance dose, the development of supporting documentation, review by a technical peer review committee, and review by the DOE community. As a result of the comments, areas have been identified for more extensive analysis, including an alternative basis for selection of the guidance dose and the development of quality assurance guidelines. Development of quality assurance guidelines will provide a reasonable basis for determining that a given waste stream qualifies as a threshold waste stream and can then be the basis for a more extensive cost-benefit analysis. The threshold guidance and supporting documentation will be revised, based on the comments received. The revised documents will be provided to DOE by early November. DOE-HQ has indicated that the revised documents will be available for review by DOE field offices and their contractors

  13. Regulatory guidance document

    International Nuclear Information System (INIS)

    1994-05-01

    The Office of Civilian Radioactive Waste Management (OCRWM) Program Management System Manual requires preparation of the OCRWM Regulatory Guidance Document (RGD) that addresses licensing, environmental compliance, and safety and health compliance. The document provides: regulatory compliance policy; guidance to OCRWM organizational elements to ensure a consistent approach when complying with regulatory requirements; strategies to achieve policy objectives; organizational responsibilities for regulatory compliance; guidance with regard to Program compliance oversight; and guidance on the contents of a project-level Regulatory Compliance Plan. The scope of the RGD includes site suitability evaluation, licensing, environmental compliance, and safety and health compliance, in accordance with the direction provided by Section 4.6.3 of the PMS Manual. Site suitability evaluation and regulatory compliance during site characterization are significant activities, particularly with regard to the YW MSA. OCRWM's evaluation of whether the Yucca Mountain site is suitable for repository development must precede its submittal of a license application to the Nuclear Regulatory Commission (NRC). Accordingly, site suitability evaluation is discussed in Chapter 4, and the general statements of policy regarding site suitability evaluation are discussed in Section 2.1. Although much of the data and analyses may initially be similar, the licensing process is discussed separately in Chapter 5. Environmental compliance is discussed in Chapter 6. Safety and Health compliance is discussed in Chapter 7

  14. PIV Logon Configuration Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Glen Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-04

    This document details the configurations and enhancements implemented to support the usage of federal Personal Identity Verification (PIV) Card for logon on unclassified networks. The guidance is a reference implementation of the configurations and enhancements deployed at the Los Alamos National Laboratory (LANL) by Network and Infrastructure Engineering – Core Services (NIE-CS).

  15. Monitoring mammary tumor progression and effect of tamoxifen treatment in MMTV-PymT using MRI and magnetic resonance spectroscopy with hyperpolarized [1-13C]pyruvate

    DEFF Research Database (Denmark)

    Asghar Butt, Sadia; Søgaard, Lise V.; Ardenkjær-Larsen, Jan Henrik

    2015-01-01

    Purpose: To use dynamic magnetic resonance spectroscopy (MRS) of hyperpolarized 13C-pyruvate to follow the progress over time in vivo of breast cancer metabolism in the MMTV-PymT model, and to follow the response to the anti-estrogen drug tamoxifen. Methods: Tumor growth was monitored by anatomical...... significantly in the treated group. Conclusion: These hyperpolarized 13C MRS findings indicate that tumor metabolic changes affects kP. The measured kp did not relate to treatment response to the same extent as did tumor growth, histological evaluation, and in vitro determination of LDH activity. © 2014 Wiley...

  16. Environmental guidance regulatory bulletin

    International Nuclear Information System (INIS)

    1997-01-01

    This document describes the background on expanding public participation in the Resource Conservation and Recovery Act and DOE's response. The bulletin also describes the changes made by the final rule to existing regulations, guidance provided by EPA in the preamble and in the revised RCRA Public Participation Manual, the relationship between public participation and environmental justice, and DOE's recent public participation and environmental justice initiatives

  17. Fat Metaplasia on Sacroiliac Joint Magnetic Resonance Imaging at Baseline Is Associated with Spinal Radiographic Progression in Patients with Axial Spondyloarthritis.

    Directory of Open Access Journals (Sweden)

    Kwi Young Kang

    Full Text Available To study the relationship between inflammatory and structural lesions in the sacroiliac joints (SIJs on MRI and spinal progression observed on conventional radiographs in patients with axial spondyloarthritis (axSpA.One hundred and ten patients who fulfilled the ASAS axSpA criteria were enrolled. All underwent SIJ MRI at baseline and lumbar spine radiographs at baseline and after 2 years. Inflammatory and structural lesions on SIJ MRI were scored using the SPondyloArthritis Research Consortium of Canada (SPARCC method. Spinal radiographs were scored using the Stoke AS Spinal Score (SASSS. Multivariate logistic regression analysis was performed to identify predictors of spinal progression.Among the 110 patients, 25 (23% showed significant radiographic progression (change of SASSS≥2 over 2 years. There was no change in the SASSS over 2 years according to the type of inflammatory lesion. Patients with fat metaplasia or ankyloses on baseline MRI showed a significantly higher SASSS at 2 years than those without (p<0.001. According to univariate logistic regression analysis, age at diagnosis, HLA-B27 positivity, the presence of fat metaplasia, erosion, and ankyloses on SIJ MRI, increased baseline CRP levels, and the presence of syndesmophytes at baseline were associated with spinal progression over 2 years. Multivariate analysis identified syndesmophytes and severe fat metaplasia on baseline SIJ MRI as predictive of spinal radiographic progression (OR, 14.74 and 5.66, respectively.Inflammatory lesions in the SIJs on baseline MRI were not associated with spinal radiographic progression. However, fat metaplasia at baseline was significantly associated with spinal progression after 2 years.

  18. The European ASAMPSA_E project : towards guidance to model the impact of high amplitude natural hazards in the probabilistic safety assessment of nuclear power plants. Information on the project progress and needs from the geosciences.

    Science.gov (United States)

    Raimond, Emmanuel; Decker, Kurt; Guigueno, Yves; Klug, Joakim; Loeffler, Horst

    2015-04-01

    The Fukushima nuclear accident in Japan resulted from the combination of two correlated extreme external events (earthquake and tsunami). The consequences, in particular flooding, went beyond what was considered in the initial engineering design design of nuclear power plants (NPPs). Such situations can in theory be identified using probabilistic safety assessment (PSA) methodology. PSA results may then lead industry (system suppliers and utilities) or Safety Authorities to take appropriate decisions to reinforce the defence-in-depth of the NPP for low probability event but high amplitude consequences. In reality, the development of such PSA remains a challenging task. Definitions of the design basis of NPPs, for example, require data on events with occurrence probabilities not higher than 10-4 per year. Today, even lower probabilities, down to 10-8, are expected and typically used for probabilistic safety analyses (PSA) of NPPs and the examination of so-called design extension conditions. Modelling the combinations of natural or man-made hazards that can affect a NPP and affecting some meaningful probability of occurrence seems to be difficult. The European project ASAMPSAE (www.asampsa.eu) gathers more than 30 organizations (industry, research, safety control) from Europe, US and Japan and aims at identifying some meaningful practices to extend the scope and the quality of the existing probabilistic safety analysis developed for nuclear power plants. It offers a framework to discuss, at a technical level, how "extended PSA" can be developed efficiently and be used to verify if the robustness of Nuclear Power Plants (NPPs) in their environment is sufficient. The paper will present the objectives of this project, some first lessons and introduce which type of guidance is being developed. It will explain the need of expertise from geosciences to support the nuclear safety assessment in the different area (seismotectonic, hydrological, meteorological and biological

  19. Note: Progress on the use of MgB2 superconducting joint technique for the development of MgB2 magnets for magnetic resonance imaging (MRI).

    Science.gov (United States)

    Kim, Y G; Song, J B; Kim, J C; Kim, J M; Yoo, B H; Yun, S B; Hwang, D Y; Lee, H G

    2017-08-01

    This note presents a superconducting joint technique for the development of MgB 2 magnetic resonance imaging (MRI) magnets. The MgB 2 superconducting joint was fabricated by a powder processing method using Mg and B powders to establish a wire-bulk-wire connection. The joint resistance measured using a field-decay method was magnets operating in the persistent current mode.

  20. Successful deep brain stimulation surgery with intraoperative magnetic resonance imaging on a difficult neuroacanthocytosis case: case report.

    Science.gov (United States)

    Lim, Thien Thien; Fernandez, Hubert H; Cooper, Scott; Wilson, Kathryn Mary K; Machado, Andre G

    2013-07-01

    Chorea acanthocytosis is a progressive hereditary neurodegenerative disorder characterized by hyperkinetic movements, seizures, and acanthocytosis in the absence of any lipid abnormality. Medical treatment is typically limited and disappointing. We report on a 32-year-old patient with chorea acanthocytosis with a failed attempt at awake deep brain stimulation (DBS) surgery due to intraoperative seizures and postoperative intracranial hematoma. He then underwent a second DBS operation, but under general anesthesia and with intraoperative magnetic resonance imaging guidance. Marked improvement in his dystonia, chorea, and overall quality of life was noted 2 and 8 months postoperatively. DBS surgery of the bilateral globus pallidus pars interna may be useful in controlling the hyperkinetic movements in neuroacanthocytosis. Because of the high propensity for seizures in this disorder, DBS performed under general anesthesia, with intraoperative magnetic resonance imaging guidance, may allow successful implantation while maintaining accurate target localization.

  1. PSD Increment Consumption Guidance

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  2. Non-cable vehicle guidance

    Energy Technology Data Exchange (ETDEWEB)

    Daugela, G.C.; Willott, A.M.; Chopiuk, R.G.; Thornton, S.E.

    1988-06-01

    The purpose is to determine the most promising driverless mine vehicle guidance systems that are not dependent on buried cables, and to plan their development. The project is presented in two phases: a preliminary study and literature review to determine whether suitable technologies exist to justify further work; and an in-depth assessment and selection of technologies for vehicle guidance. A large number of guidance elements are involved in a completely automated vehicle. The technologies that hold the best potential for development of guidance systems for mine vehicles are ultrasonics, radar, lasers, dead reckoning, and guidance algorithms. The best approach to adaptation of these technologies is on a step by step basis. Guidance modules that are complete in themselves and are designed to be integrated with other modules can provide short term benefits. Two modules are selected for development: the dragline operations monitor and automated machine control for optimized mining (AMCOM). 99 refs., 20 figs., 40 tabs.

  3. Determination of neutron cross sections and resonance parameters for vanadium, the stable thallium isotopes, and the stable tellurium isotopes. Progress report, October 1, 1976--October 31, 1977

    International Nuclear Information System (INIS)

    Winters, R.R.

    1977-10-01

    The analysis of the neutron capture cross section data for 51 V + n has now been completed up to 215 keV. Using a few neutron widths and spin and parity assignments from the literature, the capture data has yielded estimates of radiative widths for 45 s-wave resonances and capture areas for 139 resonances. Of particular interest is the very large s-wave radiative widths for this reaction and the rather broad distribution of radiative widths. A paper describing these results is included with this report. The analysis of the neutron capture cross sections for the reaction 205 Tl(n,γ) is presently being extended to incident neutron energy 115 keV. The study of the scattered-beam sensitivity of the total energy detectors at the ORELA capture facility continues. This small but troublesome effect has now been parameterized, but the errors to be assigned to the parameterization are not yet well defined. However, in obtaining additional data for the parameterization, a series of 208 Pb(n,γ) cross section measurements were made. The analysis of these data led to results important in understanding stellar nucleosynthesis and are reported in a paper included with this report. the analysis of the Te(n,γ) data proceeds methodically but slowly

  4. Method for plant operation guidance by knowledge engineering technique

    International Nuclear Information System (INIS)

    Kiguchi, Takashi; Yoshida, Kenichi; Motoda, Hiroshi; Kobayashi, Setsuo

    1983-01-01

    A method for plant operation guidance has been developed by using the Knowledge Engineering technique. The method is characterized by its capability of handling plant dynamics. The knowledge-base includes plant simulation programs as tools to evaluate dynamic behaviors as well as production rules of ''if..., then...'' type. The inference engine is thus capable of predicting plant dynamics and making decisions in accordance with time progress. The performance of the guidance method was evaluated by simulation tests assuming various abnormal situations of a BWR power plant. It was shown that the method can detect each of the abnormal events along the course of their occurrence, and provide the guidance for corrective actions. The operation guidance method proposed in this paper is general and is applicable not only to nuclear power plants but also to other plants such as chemical production plants and fossile power plants. (author)

  5. Draft Guidance for Protective Action Strategies Development

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Hyun; Jeong, Seung Young; Kim, Wanjoo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    National nuclear emergency preparedness and response (EPR) framework has been improved since the Fukushima accident in 2011. There are still many needs to be amended and improved in regulatory requirements and technical criteria to warrant efficacy of the EPR framework. As an important part of the framework, protective actions have to be implemented with optimized and justified manner during whole emergency phases. In this study, to enhance protective action strategies in response to severe accident or general emergency, existing procedures were reviewed. And generic guidance to develop protective action recommendations (PARs) was proposed considering revised EPZ and recent technical information on protective action strategies. The generic guidance for PARs based on facility status was introduced. Revision of EPZ and some recent information on protective action strategies, such as staged evacuation, specific approach for rapidly progressing accident were considered. It would be employed as a basis to develop site-specific strategies of PARs and regulatory guidance for emergency plan by nuclear licensee. It was focused on an early phase of nuclear emergency. Further efforts to develop site specific strategies of PARs and strategies which cover full range of nuclear emergency would be followed by several stake holders.

  6. NRC ARDC Guidance Support Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Holbrook, Mark R. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-07-01

    This report provides a summary that reflects the progress and status of proposed regulatory design criteria for advanced non-light water reactor (LWR) designs in accordance with the Level 3 milestone M3AT-17IN2001013 in work package AT-17IN200101. These criteria have been designated as advanced reactor design criteria (ARDC) and they provide guidance to future applicants for addressing the general design criteria (GDC) that are currently applied specifically to LWR designs. This report provides a summary of Phase 2 activities related to the various tasks associated with ARDC development and the subsequent development of ARDC regulatory guidance for sodium fast reactor (SFR) and modular high-temperature gas-cooled reactor (HTGR) designs. Status Report Organization: Section 2 discusses the origin of the GDC and their application to LWRs. Section 3 addresses the objective of this initiative and how it benefits the advanced non-LWR reactor vendors. Section 4 discusses the scope and structure of the initiative. Section 5 provides background on the U.S. Department of Energy (DOE) ARDC team’s original development of the proposed ARDC that were submitted to the NRC for consideration. Section 6 provides a summary of recent ARDC Phase 2 activities. Appendices A through E document the DOE ARDC team’s public comments on various sections of the NRC’s draft regulatory guide DG–1330, “Guidance for Developing Principal Design Criteria for Non-Light Water Reactors.”

  7. NRC ARDC Guidance Support Status Report

    International Nuclear Information System (INIS)

    Holbrook, Mark R.

    2017-01-01

    This report provides a summary that reflects the progress and status of proposed regulatory design criteria for advanced non-light water reactor (LWR) designs in accordance with the Level 3 milestone M3AT-17IN2001013 in work package AT-17IN200101. These criteria have been designated as advanced reactor design criteria (ARDC) and they provide guidance to future applicants for addressing the general design criteria (GDC) that are currently applied specifically to LWR designs. This report provides a summary of Phase 2 activities related to the various tasks associated with ARDC development and the subsequent development of ARDC regulatory guidance for sodium fast reactor (SFR) and modular high-temperature gas-cooled reactor (HTGR) designs. Status Report Organization: Section 2 discusses the origin of the GDC and their application to LWRs. Section 3 addresses the objective of this initiative and how it benefits the advanced non-LWR reactor vendors. Section 4 discusses the scope and structure of the initiative. Section 5 provides background on the U.S. Department of Energy (DOE) ARDC team’s original development of the proposed ARDC that were submitted to the NRC for consideration. Section 6 provides a summary of recent ARDC Phase 2 activities. Appendices A through E document the DOE ARDC team’s public comments on various sections of the NRC’s draft regulatory guide DG–1330, “Guidance for Developing Principal Design Criteria for Non-Light Water Reactors.”

  8. Impact of a magnetic resonance imaging-guided treat-to-target strategy on disease activity and progression in patients with rheumatoid arthritis (the IMAGINE-RA trial)

    DEFF Research Database (Denmark)

    Møller-Bisgaard, Signe; Hørslev-Petersen, Kim; Ejbjerg, Bo Jannik

    2015-01-01

    /absence of BME may therefore be clinically beneficial. We present the design of a randomized controlled trial (RCT) aiming to evaluate whether an MRI-guided treatment strategy compared to a conventional treatment strategy in anti-CCP-positive erosive RA is better to prevent progression of erosive joint damage...... swollen joints and treatment with synthetic disease-modifying antirheumatic drugs (DMARDs) will be included. Patients will be randomized to either a treatment strategy based on conventional laboratory and clinical examinations (control group) or a treatment strategy based on conventional laboratory...

  9. Resonance formation in photon-photon collisions

    International Nuclear Information System (INIS)

    Gidal, G.

    1988-08-01

    Recent experimental progress on resonance formation in photon-photon collisions is reviewed with particular emphasis on the pseudoscalar and tensor nonents and on the γγ* production of spin-one resonances. 37 refs., 17 figs., 5 tabs

  10. International guidance activities

    International Nuclear Information System (INIS)

    Richardson, Allan C.B.

    1989-01-01

    International principles for setting Protective Action Guides (PAGs) are contained in two key documents that contain identical statements. One is Publication Number 40 of the ICRP, which was issued in 1985. The title is 'Protection of the Public in the Event of Major Radiation Accidents, Principles for Planning'. The other is the IAEA's Safety Series Publication Number 72, also issued in 1985, written by many of the same authors and titled, 'Principles for Establishing Intervention Levels'. The principles that were set forth in these documents were identical, were incomplete, and they are, unfortunately, the only principles that are now in effect, while proposed revisions go through one draft after another. There are several such draft revisions that are of significance. The most important is that of the ICRP. The basic guidance that applies to most planned exposure to radiation is ICRP Publication 26. That document has been under revision by the Commission for a number of years, and the new version will, for the first time, include recommendations for emergency response. They are now getting close to closure, and I think it should be a very much improved and useful document. But it isn't finished yet. Such guidance doesn't get developed in a vacuum, and there have been a couple of parallel efforts which have provided significant input to the ICRP, which is essentially a behind-closed-doors effort. These other efforts are more open. One of these is being carried out within the IAEA, which has convened annual meetings of national experts for a number of years in Vienna, to generate a replacement for Safety Series No. 72, mentioned earlier. There is a meeting scheduled this December to complete this effort; and, hopefully, we will reach closure at that meeting on at least the basic principles. The Nuclear Energy Agency (NEA) has also been at work. It has convened a group of experts from member nations that have been developing recommendations. There is an overlap

  11. RH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2006-01-01

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' It further states: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M and O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 Code of Federal Regulations (CFR) 1.8, 'Deliberate Misconduct.' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, 'Packaging and Transportation of Radioactive Material,' certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, 'Reporting of Defects and Noncompliance,' regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these

  12. RH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2008-01-01

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package (also known as the 'RH-TRU 72-B cask') and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' It further states: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M and O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8, 'Deliberate Misconduct.' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, 'Packaging and Transportation of Radioactive Material,' certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, 'Reporting of Defects and Noncompliance,' regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous

  13. Dissecting Attending Surgeons' Operating Room Guidance: Factors That Affect Guidance Decision Making.

    Science.gov (United States)

    Chen, Xiaodong Phoenix; Williams, Reed G; Smink, Douglas S

    2015-01-01

    The amount of guidance provided by the attending surgeon in the operating room (OR) is a key element in developing residents' autonomy. The purpose of this study is to explore factors that affect attending surgeons' decision making regarding OR guidance provided to the resident. We used video-stimulated recall interviews (VSRI) throughout this 2-phase study. In Phase 1, 3 attending surgeons were invited to review separately 30 to 45 minute video segments of their prerecorded surgical operations to explore factors that influenced their OR guidance decision making. In Phase 2, 3 attending surgeons were observed and documented in the OR (4 operations, 341min). Each operating surgeon reviewed their videotaped surgical performance within 5 days of the operation to reflect on factors that affected their decision making during the targeted guidance events. All VSRI were recorded. Thematic analysis and manual coding were used to synthesize and analyze data from VSRI transcripts, OR observation documents, and field notes. A total of 255 minutes of VSRI involving 6 surgeons and 7 surgical operations from 5 different procedures were conducted. A total of 13 guidance decision-making influence factors from 4 categories were identified (Cohen's κ = 0.674): Setting (case schedule and patient morbidity), content (procedure attributes and case progress), resident (current competency level, trustworthiness, self-confidence, and personal traits), and attending surgeon (level of experience, level of comfort, preferred surgical technique, OR training philosophy, and responsibility as surgeon). A total of 5 factors (case schedule, patient morbidity, procedure attributes, resident current competency level, and trustworthiness) influenced attending surgeons' pre-OR guidance plans. "OR training philosophy" and "responsibility as surgeon" were anchor factors that affected attending surgeons' OR guidance decision-making patterns. Surgeons' OR guidance decision making is a dynamic process

  14. Historical Development of Guidance and Counseling and Implications for the Future

    Science.gov (United States)

    Aubrey, Roger F.

    1977-01-01

    The author traces the development of guidance and counseling from the nineteenth century to the present with implications for the future. The impact of the progressive movement, vocational guidance, industrialization, psychometrics, and Carl Rogers are highlighted. The 1950's are singled out as the decade having the greatest effect on counselors.…

  15. The Consideration of a Constructivist Evaluation Framework in Adult Guidance Practice

    Science.gov (United States)

    Hearne, Lucy

    2011-01-01

    This article explores the findings of a doctoral study that examined the measurement of individual progression in the Irish Adult Education Guidance Initiative. The critical constructivist stance of the study challenges the prevalence of the positivist paradigm to evaluate long-term outcomes in adult guidance. The research highlights the…

  16. Plowshare radiation protection guidance

    International Nuclear Information System (INIS)

    Parker, H.M.

    1969-01-01

    The recommendations of the ICRP and the NCRP were developed primarily for occupational radiation exposures. They were later modified and applied to non-occupational exposures of populations. These, with appropriate interpretations, can be used to provide Plowshare radiation protection guidance. Exposures from Plowshare operations will tend to be acute, arising from radionuclides of relatively short half-life, but will have some chronic aspects due to small amounts of long-lived radionuclides generated. In addition, the neutron activation process of Plowshare technology will produce radionuclides not commonly encountered in routine nuclear energy programs. How these radionuclides contribute to personnel exposure is known for only a few situations that may not be representative of Plowshare exposure. Further complications arise from differences in radionuclide deposition and physiological sensitivity among individuals of different ages and states of health in the exposed population. All parameters necessary to evaluate such exposures are not available, even for good quantitative approximations, resulting in the need for interpretive experience. (author)

  17. Plowshare radiation protection guidance

    Energy Technology Data Exchange (ETDEWEB)

    Parker, H M [Environmental and Life Sciences Division, Battelle Memorial Institute, Pacific Northwest Laboratory, Richland, WA (United States)

    1969-07-01

    The recommendations of the ICRP and the NCRP were developed primarily for occupational radiation exposures. They were later modified and applied to non-occupational exposures of populations. These, with appropriate interpretations, can be used to provide Plowshare radiation protection guidance. Exposures from Plowshare operations will tend to be acute, arising from radionuclides of relatively short half-life, but will have some chronic aspects due to small amounts of long-lived radionuclides generated. In addition, the neutron activation process of Plowshare technology will produce radionuclides not commonly encountered in routine nuclear energy programs. How these radionuclides contribute to personnel exposure is known for only a few situations that may not be representative of Plowshare exposure. Further complications arise from differences in radionuclide deposition and physiological sensitivity among individuals of different ages and states of health in the exposed population. All parameters necessary to evaluate such exposures are not available, even for good quantitative approximations, resulting in the need for interpretive experience. (author)

  18. NGST fine guidance sensor

    Science.gov (United States)

    Rowlands, Neil; Hutchings, John; Murowinski, Richard G.; Alexander, Russ

    2003-03-01

    Instrumentation for the Next Generation Space Telescope (NGST) is currently in the Phase A definition stage. We have developed a concept for the NGST Fine Guidance Sensor or FGS. The FGS is a detector array based imager which resides in the NGST focal plane. We report here on tradeoff studies aimed at defining an overall configuration of the FGS which will meet the performance and interface requirements. A key performance requirement is a noise equivalent angle of 3 milli-arcseconds to be achieved with 95% probability for any pointing of the observatory in the celestial sphere. A key interface requirement is compatibility with the architecture of the Integrated Science Instrument Module (ISIM). The concept developed consists of two independent and redundant FGS modules, each with a 4' x 2' field of view covered by two 2048 x 2048 infrared detector arrays, providing 60 milli-arcsecond sampling. Performance modeling supporting the choice of this architecture and the trade space considered is presented. Each module has a set of readout electronics which perform star detection, pixel-by-pixel correction, and in fine guiding mode, centroid calculation. These readout electronics communicate with the ISIM Command &Data Handling Units where the FGS control software is based. Rationale for this choice of architecture is also presented.

  19. Changes in water content and distribution in Quercus ilex leaves during progressive drought assessed by in vivo 1H magnetic resonance imaging.

    Science.gov (United States)

    Sardans, Jordi; Peñuelas, Josep; Lope-Piedrafita, Silvia

    2010-08-24

    Drought is a common stressor in many regions of the world and current climatic global circulation models predict further increases in warming and drought in the coming decades in several of these regions, such as the Mediterranean basin. The changes in leaf water content, distribution and dynamics in plant tissues under different soil water availabilities are not well known. In order to fill this gap, in the present report we describe our study withholding the irrigation of the seedlings of Quercus ilex, the dominant tree species in the evergreen forests of many areas of the Mediterranean Basin. We have monitored the gradual changes in water content in the different leaf areas, in vivo and non-invasively, by 1H magnetic resonance imaging (MRI) using proton density weighted (rhow) images and spin-spin relaxation time (T2) maps. Rhow images showed that the distal leaf area lost water faster than the basal area and that after four weeks of similar losses, the water reduction was greater in leaf veins than in leaf parenchyma areas and also in distal than in basal leaf area. There was a similar tendency in all different areas and tissues, of increasing T2 values during the drought period. This indicates an increase in the dynamics of free water, suggesting a decrease of cell membranes permeability. The results indicate a non homogeneous leaf response to stress with a differentiated capacity to mobilize water between its different parts and tissues. This study shows that the MRI technique can be a useful tool to follow non-intrusively the in vivo water content changes in the different parts of the leaves during drought stress. It opens up new possibilities to better characterize the associated physiological changes and provides important information about the different responses of the different leaf areas what should be taken into account when conducting physiological and metabolic drought stress studies in different parts of the leaves during drought stress.

  20. Visual evoked potential and magnetic resonance imaging are more effective markers of multiple sclerosis progression than laser polarimetry with variable corneal compensation

    Directory of Open Access Journals (Sweden)

    Ema eKantorová

    2014-01-01

    Full Text Available Backround: The aim of our study was to assess the role of laser polarimetry and visual evoked potentials as potential biomarkers of disease progression in multiple sclerosis (MS. Participants: A total of 41 patients with MS (82 eyes and 22 age-related healthy volunteers (44 eyes completed the study. MS patients were divided into two groups, one (ON with a history of optic neuritis (17 patients, 34 eyes and another group (NON without it (24 patients, 48 eyes. The MS patients and controls underwent laser polarimetry (GDx examination of the retinal nerve fibre layer (RNFL. In the MS group we also examined: Kurtzke Expanded disability status scale (EDSS, the duration of the disorder, visual evoked potentials (VEP – latency and amplitude – and conventional brain MRI. Results: In the MS group, brain atrophy and new T2 brain lesions in MRI correlated with both VEP latencies and amplitudes. Separate comparisons revealed VEP latency testing to be less sensitive in ON than in NON patients. In ON patients, VEP amplitudes correlated mildly with brain atrophy (r =-0.15 and strongly with brain new MRI lesions (r = -0.8. In NON patients, highly significant correlation of new MRI brain lesions with VEP latencies (r = 0.63, r = 0.6, and amplitudes ( r = -0.3, r = -4.2 was found. EDSS also correlated with brain atrophy in this group (r = 0.5. Our study did not find a correlation of GDx measures with MRI tests. The GDx method was not able to detect whole brain demyelinisation and the degeneration process, but was only able to reveal the involvement of optic nerves in ON and NON patients.Conclusions: In our study, we found that both methods (VEP and GDx can be used for detection of optic nerve damage, but VEP was found to be superior in evaluating whole brain demyelinisation and axonal degeneration. Both VEP and MRI, but not GDx, have an important role in monitoring disease progression in MS patients, independent of the ON history.

  1. General RMP Guidance - Appendix D: OSHA Guidance on PSM

    Science.gov (United States)

    OSHA's Process Safety Management (PSM) Guidance on providing complete and accurate written information concerning process chemicals, process technology, and process equipment; including process hazard analysis and material safety data sheets.

  2. Defining active progressive multiple sclerosis

    DEFF Research Database (Denmark)

    Sellebjerg, Finn; Börnsen, Lars; Ammitzbøll, Cecilie

    2017-01-01

    BACKGROUND: It is unknown whether disease activity according to consensus criteria (magnetic resonance imaging activity or clinical relapses) associate with cerebrospinal fluid (CSF) changes in progressive multiple sclerosis (MS). OBJECTIVE: To compare CSF biomarkers in active and inactive...

  3. CAREER GUIDANCE EXPERIENCE ABROAD

    Directory of Open Access Journals (Sweden)

    Sergey N. Tolstoguzov

    2015-01-01

    Full Text Available The aim of this paper is to describe the experience of careeroriented activities carried out with students of schools in developed and developing countries. Career Guidance in Russia, despite the vast experience of its implementation, is experiencing serious difficulties. In this regard, it is important to take into account the international experience career-oriented activities, such as in the developed countries of North America and the European Union as well as in several Asian countries with rapidly growing economies and a large demographic potential, taking into account the best variants for the Russian education system. Methods. The experience of career-oriented work undertaken with pupils of the USA, Canada, Israel, France, UK, Germany, Denmark, Sweden, Japan, Singapore, China and India is shown on the basis of the comparative analysis of different publications and information sources. The author has made an attempt to generalize the principles of psycho-pedagogical and administrative assistance in professional self-determination of senior pupils abroad. Scientific novelty. The approaches to career-oriented activities in countries with different levels of economic development are compared for the first time. Some principles are revealed. Firstly, the higher the income level per capita in the country, the greater attention is given to vocational guidance. The politics in the developed countries is based on interests of the individual: children’s acquaintance with the world of professions begins already at younger school and the moment of definitive selfdetermination is postponed till the end of their senior stage of education; the possibility of direction change of professional preparation in case of detection of discrepancy of qualities of the pupil to originally selected profile is provided. Career-oriented activity in developing countries, on the contrary, is rigidly coordinated to requirements of economy and a labour market

  4. RH Packaging Program Guidance

    International Nuclear Information System (INIS)

    Washington TRU Solutions, LLC

    2003-01-01

    The purpose of this program guidance document is to provide technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the SARP and/or C of C shall govern. The C of C states: ''...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, ''Operating Procedures,'' of the application.'' It further states: ''...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, ''Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M and O) contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC approved, users need to be familiar with 10 CFR (section) 71.11, ''Deliberate Misconduct.'' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions. Following these instructions assures that operations are safe and meet the requirements of the SARP. This document is available on the Internet at: ttp://www.ws/library/t2omi/t2omi.htm. Users are responsible for ensuring they are using the current revision and change notices. Sites may prepare their own document using the word

  5. The continuum of behavior guidance.

    Science.gov (United States)

    Nelson, Travis

    2013-01-01

    Behavior guidance is a continuum of techniques, basic and advanced, fundamental to the provision of quality dental care for pediatric patients. This practice must be individualized, pairing the correct method of behavior guidance with each child. To select the appropriate technique, the clinician must have a thorough understanding of each aspect of the continuum and anticipate parental expectations, child temperament, and the technical procedures necessary to complete care. By effectively using techniques within the continuum of behavior guidance, a healing relationship with the family is maintained while addressing dental disease and empowering the child to receive dental treatment throughout their lifetime. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Regulatory guidance for license renewal

    International Nuclear Information System (INIS)

    Thoma, John A.

    1991-01-01

    The proposed 10 CFR Part 54 rule proceduralizes the process for license renewal by identifying both the administrative and technical requirements for a renewal application. To amplify and support this regulation, written guidance has been provided in the form of a draft Regulatory Guide (DG 1009) and a draft Standard Review Plan for License Renewal (NUREG 1299). This guidance is scheduled to be finalized in 1992. Similar guidance will be provided for the proposed revisions to 10 CFR Part 51 concerning the environmental aspects of license renewal. (author)

  7. Changes in water content and distribution in Quercus ilex leaves during progressive drought assessed by in vivo 1H magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Sardans Jordi

    2010-08-01

    Full Text Available Abstract Background Drought is a common stressor in many regions of the world and current climatic global circulation models predict further increases in warming and drought in the coming decades in several of these regions, such as the Mediterranean basin. The changes in leaf water content, distribution and dynamics in plant tissues under different soil water availabilities are not well known. In order to fill this gap, in the present report we describe our study withholding the irrigation of the seedlings of Quercus ilex, the dominant tree species in the evergreen forests of many areas of the Mediterranean Basin. We have monitored the gradual changes in water content in the different leaf areas, in vivo and non-invasively, by 1H magnetic resonance imaging (MRI using proton density weighted (ρw images and spin-spin relaxation time (T2 maps. Results ρw images showed that the distal leaf area lost water faster than the basal area and that after four weeks of similar losses, the water reduction was greater in leaf veins than in leaf parenchyma areas and also in distal than in basal leaf area. There was a similar tendency in all different areas and tissues, of increasing T2 values during the drought period. This indicates an increase in the dynamics of free water, suggesting a decrease of cell membranes permeability. Conclusions The results indicate a non homogeneous leaf response to stress with a differentiated capacity to mobilize water between its different parts and tissues. This study shows that the MRI technique can be a useful tool to follow non-intrusively the in vivo water content changes in the different parts of the leaves during drought stress. It opens up new possibilities to better characterize the associated physiological changes and provides important information about the different responses of the different leaf areas what should be taken into account when conducting physiological and metabolic drought stress studies in

  8. Recent progress in Biophysics

    International Nuclear Information System (INIS)

    Bemski, G.

    1980-03-01

    Recent progress in biophysics is reviewed, and three examples of the use of physical techniques and ideas in biological research are given. The first one deals with the oxygen transporting protein-hemoglobin, the second one with photosynthesis, and the third one with image formation, using nuclear magnetic resonance. (Author) [pt

  9. SPLC Sustainable Purchasing Guidance Profile

    Science.gov (United States)

    To help you find the resource that is right for your organization, EPA conducted a scan of the landscape and developed summary profiles of some of the leading sources of sustainable purchasing guidance around the globe.

  10. CDM Convective Forecast Planning guidance

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The CDM Convective Forecast Planning (CCFP) guidance product provides a foreast of en-route aviation convective hazards. The forecasts are updated every 2 hours and...

  11. Guidance at the educational marketplace

    DEFF Research Database (Denmark)

    Lystbæk, Christian Tang

    in educational policies and institutions. As educational systems have expanded and, further, have been restructured with the expansion of choice opportunities since the 1980s, guidance has become prioritized as a form of counseling or coaching, which can support students. Thus, guidance has become an important...... `agent´ on the educational "market´, assisting (potential) students into and around the `marketplace´. Consequently, guidance is also an important `agent´ for educational institutions that increasingly use marketing strategies to promote themselves on the market to attract and hold on to their “customers......” in order for the institutions to increase their ´market value´, `sales” and “turnover”. Thus, the expansion of guidance is nurtured by the expansion of the logic of marketization and consumerism. Drawing on Foucauldian perspectives in educational research, which highlight the expansion of powerful...

  12. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  13. White matter lesion progression

    DEFF Research Database (Denmark)

    Hofer, Edith; Cavalieri, Margherita; Bis, Joshua C

    2015-01-01

    10 cohorts. To assess the relative contribution of genetic factors to progression of WML, we compared in 7 cohorts risk models including demographics, vascular risk factors plus single-nucleotide polymorphisms that have been shown to be associated cross-sectionally with WML in the current......BACKGROUND AND PURPOSE: White matter lesion (WML) progression on magnetic resonance imaging is related to cognitive decline and stroke, but its determinants besides baseline WML burden are largely unknown. Here, we estimated heritability of WML progression, and sought common genetic variants...... associated with WML progression in elderly participants from the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) consortium. METHODS: Heritability of WML progression was calculated in the Framingham Heart Study. The genome-wide association study included 7773 elderly participants from...

  14. Quality in career guidance: The Danish case

    DEFF Research Database (Denmark)

    Plant, Peter

    2011-01-01

    Quality assurance systems are introduced in career guidance to monitor, control and develop guidance interventions. The Danish case represents at centrally driven, top-down approach......Quality assurance systems are introduced in career guidance to monitor, control and develop guidance interventions. The Danish case represents at centrally driven, top-down approach...

  15. Magnetic Resonance Parkinsonism Index: diagnostic accuracy of a fully automated algorithm in comparison with the manual measurement in a large Italian multicentre study in patients with progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Nigro, Salvatore; Arabia, Gennarina; Antonini, Angelo; Weis, Luca; Marcante, Andrea; Tessitore, Alessandro; Cirillo, Mario; Tedeschi, Gioacchino; Zanigni, Stefano; Tonon, Caterina; Calandra-Buonaura, Giovanna; Pezzoli, Gianni; Cilia, Roberto; Zappia, Mario; Nicoletti, Alessandra; Cicero, Calogero Edoardo; Tinazzi, Michele; Tocco, Pierluigi; Cardobi, Nicolo; Quattrone, Aldo

    2017-01-01

    To investigate the reliability of a new in-house automatic algorithm for calculating the Magnetic Resonance Parkinsonism Index (MRPI), in a large multicentre study population of patients affected by progressive supranuclear palsy (PSP) or Parkinson's disease (PD), and healthy controls (HC), and to compare the diagnostic accuracy of the automatic and manual MRPI values. The study included 88 PSP patients, 234 PD patients and 117 controls. MRI was performed using both 3T and 1.5T scanners. Automatic and manual MRPI values were evaluated, and accuracy of both methods in distinguishing PSP from PD and controls was calculated. No statistical differences were found between automated and manual MRPI values in all groups. The automatic MRPI values differentiated PSP from PD with an accuracy of 95 % (manual MRPI accuracy 96 %) and 97 % (manual MRPI accuracy 100 %) for 1.5T and 3T scanners, respectively. Our study showed that the new in-house automated method for MRPI calculation was highly accurate in distinguishing PSP from PD. Our automatic approach allows a widespread use of MRPI in clinical practice and in longitudinal research studies. (orig.)

  16. Magnetic Resonance Parkinsonism Index: diagnostic accuracy of a fully automated algorithm in comparison with the manual measurement in a large Italian multicentre study in patients with progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Nigro, Salvatore [National Research Council, Institute of Bioimaging and Molecular Physiology, Catanzaro (Italy); Arabia, Gennarina [University ' ' Magna Graecia' ' , Institute of Neurology, Department of Medical and Surgical Sciences, Catanzaro (Italy); Antonini, Angelo; Weis, Luca; Marcante, Andrea [' ' Fondazione Ospedale San Camillo' ' - I.R.C.C.S, Parkinson' s Disease and Movement Disorders Unit, Venice-Lido (Italy); Tessitore, Alessandro; Cirillo, Mario; Tedeschi, Gioacchino [Second University of Naples, Department of Medical, Surgical, Neurological, Metabolic and Aging Sciences, Naples (Italy); Second University of Naples, MRI Research Center SUN-FISM, Naples (Italy); Zanigni, Stefano; Tonon, Caterina [Policlinico S. Orsola - Malpighi, Functional MR Unit, Bologna (Italy); University of Bologna, Department of Biomedical and Neuromotor Sciences, Bologna (Italy); Calandra-Buonaura, Giovanna [University of Bologna, Department of Biomedical and Neuromotor Sciences, Bologna (Italy); IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna (Italy); Pezzoli, Gianni; Cilia, Roberto [ASST G.Pini - CTO, ex ICP, Parkinson Institute, Milano (Italy); Zappia, Mario; Nicoletti, Alessandra; Cicero, Calogero Edoardo [University of Catania, Department ' ' G.F. Ingrassia' ' , Section of Neurosciences, Catania (Italy); Tinazzi, Michele; Tocco, Pierluigi [University Hospital of Verona, Department of Neurological and Movement Sciences, Verona (Italy); Cardobi, Nicolo [University Hospital of Verona, Institute of Radiology, Verona (Italy); Quattrone, Aldo [National Research Council, Institute of Bioimaging and Molecular Physiology, Catanzaro (Italy); University ' ' Magna Graecia' ' , Institute of Neurology, Department of Medical and Surgical Sciences, Catanzaro (Italy)

    2017-06-15

    To investigate the reliability of a new in-house automatic algorithm for calculating the Magnetic Resonance Parkinsonism Index (MRPI), in a large multicentre study population of patients affected by progressive supranuclear palsy (PSP) or Parkinson's disease (PD), and healthy controls (HC), and to compare the diagnostic accuracy of the automatic and manual MRPI values. The study included 88 PSP patients, 234 PD patients and 117 controls. MRI was performed using both 3T and 1.5T scanners. Automatic and manual MRPI values were evaluated, and accuracy of both methods in distinguishing PSP from PD and controls was calculated. No statistical differences were found between automated and manual MRPI values in all groups. The automatic MRPI values differentiated PSP from PD with an accuracy of 95 % (manual MRPI accuracy 96 %) and 97 % (manual MRPI accuracy 100 %) for 1.5T and 3T scanners, respectively. Our study showed that the new in-house automated method for MRPI calculation was highly accurate in distinguishing PSP from PD. Our automatic approach allows a widespread use of MRPI in clinical practice and in longitudinal research studies. (orig.)

  17. Approach to DOE threshold guidance limits

    International Nuclear Information System (INIS)

    Shuman, R.D.; Wickham, L.E.

    1984-01-01

    The need for less restrictive criteria governing disposal of extremely low-level radioactive waste has long been recognized. The Low-Level Waste Management Program has been directed by the Department of Energy (DOE) to aid in the development of a threshold guidance limit for DOE low-level waste facilities. Project objectives are concernd with the definition of a threshold limit dose and pathway analysis of radionuclide transport within selected exposure scenarios at DOE sites. Results of the pathway analysis will be used to determine waste radionuclide concentration guidelines that meet the defined threshold limit dose. Methods of measurement and verification of concentration limits round out the project's goals. Work on defining a threshold limit dose is nearing completion. Pathway analysis of sanitary landfill operations at the Savannah River Plant and the Idaho National Engineering Laboratory is in progress using the DOSTOMAN computer code. Concentration limit calculations and determination of implementation procedures shall follow completion of the pathways work. 4 references

  18. Information architecture. Volume 3: Guidance

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-04-01

    The purpose of this document, as presented in Volume 1, The Foundations, is to assist the Department of Energy (DOE) in developing and promulgating information architecture guidance. This guidance is aimed at increasing the development of information architecture as a Departmentwide management best practice. This document describes departmental information architecture principles and minimum design characteristics for systems and infrastructures within the DOE Information Architecture Conceptual Model, and establishes a Departmentwide standards-based architecture program. The publication of this document fulfills the commitment to address guiding principles, promote standard architectural practices, and provide technical guidance. This document guides the transition from the baseline or defacto Departmental architecture through approved information management program plans and budgets to the future vision architecture. This document also represents another major step toward establishing a well-organized, logical foundation for the DOE information architecture.

  19. Multiphoton resonances

    International Nuclear Information System (INIS)

    Shore, B.W.

    1977-01-01

    The long-time average of level populations in a coherently-excited anharmonic sequence of energy levels (e.g., an anharmonic oscillator) exhibits sharp resonances as a function of laser frequency. For simple linearly-increasing anharmonicity, each resonance is a superposition of various multiphoton resonances (e.g., a superposition of 3, 5, 7, . . . photon resonances), each having its own characteristic width predictable from perturbation theory

  20. DOE Waste Treatability Group Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, T.D.

    1995-01-01

    This guidance presents a method and definitions for aggregating U.S. Department of Energy (DOE) waste into streams and treatability groups based on characteristic parameters that influence waste management technology needs. Adaptable to all DOE waste types (i.e., radioactive waste, hazardous waste, mixed waste, sanitary waste), the guidance establishes categories and definitions that reflect variations within the radiological, matrix (e.g., bulk physical/chemical form), and regulated contaminant characteristics of DOE waste. Beginning at the waste container level, the guidance presents a logical approach to implementing the characteristic parameter categories as part of the basis for defining waste streams and as the sole basis for assigning streams to treatability groups. Implementation of this guidance at each DOE site will facilitate the development of technically defined, site-specific waste stream data sets to support waste management planning and reporting activities. Consistent implementation at all of the sites will enable aggregation of the site-specific waste stream data sets into comparable national data sets to support these activities at a DOE complex-wide level.

  1. Agent Based Individual Traffic Guidance

    DEFF Research Database (Denmark)

    Wanscher, Jørgen

    of the project were not previously considered. We define a special inseparable cost function and develop a solution complex capable of using this cost function. In relation to calibration and estimation of statistical models used for dynamic route guidance we worked with generating random number sequences...

  2. Consensus standard requirements and guidance

    International Nuclear Information System (INIS)

    Putman, V.L.

    1995-01-01

    This report presents information from the ANS Criticality Alarm System Workshop relating to the consensus standard requirements and guidance. Topics presented include: definition; nomenclature; requirements and recommendations; purpose of criticality alarms; design criteria; signal characteristics; reliability, dependability and durability; tests; and emergency preparedness and planning

  3. DOE Waste Treatability Group Guidance

    International Nuclear Information System (INIS)

    Kirkpatrick, T.D.

    1995-01-01

    This guidance presents a method and definitions for aggregating U.S. Department of Energy (DOE) waste into streams and treatability groups based on characteristic parameters that influence waste management technology needs. Adaptable to all DOE waste types (i.e., radioactive waste, hazardous waste, mixed waste, sanitary waste), the guidance establishes categories and definitions that reflect variations within the radiological, matrix (e.g., bulk physical/chemical form), and regulated contaminant characteristics of DOE waste. Beginning at the waste container level, the guidance presents a logical approach to implementing the characteristic parameter categories as part of the basis for defining waste streams and as the sole basis for assigning streams to treatability groups. Implementation of this guidance at each DOE site will facilitate the development of technically defined, site-specific waste stream data sets to support waste management planning and reporting activities. Consistent implementation at all of the sites will enable aggregation of the site-specific waste stream data sets into comparable national data sets to support these activities at a DOE complex-wide level

  4. Stochastic resonance

    International Nuclear Information System (INIS)

    Wellens, Thomas; Shatokhin, Vyacheslav; Buchleitner, Andreas

    2004-01-01

    We are taught by conventional wisdom that the transmission and detection of signals is hindered by noise. However, during the last two decades, the paradigm of stochastic resonance (SR) proved this assertion wrong: indeed, addition of the appropriate amount of noise can boost a signal and hence facilitate its detection in a noisy environment. Due to its simplicity and robustness, SR has been implemented by mother nature on almost every scale, thus attracting interdisciplinary interest from physicists, geologists, engineers, biologists and medical doctors, who nowadays use it as an instrument for their specific purposes. At the present time, there exist a lot of diversified models of SR. Taking into account the progress achieved in both theoretical understanding and practical application of this phenomenon, we put the focus of the present review not on discussing in depth technical details of different models and approaches but rather on presenting a general and clear physical picture of SR on a pedagogical level. Particular emphasis will be given to the implementation of SR in generic quantum systems-an issue that has received limited attention in earlier review papers on the topic. The major part of our presentation relies on the two-state model of SR (or on simple variants thereof), which is general enough to exhibit the main features of SR and, in fact, covers many (if not most) of the examples of SR published so far. In order to highlight the diversity of the two-state model, we shall discuss several examples from such different fields as condensed matter, nonlinear and quantum optics and biophysics. Finally, we also discuss some situations that go beyond the generic SR scenario but are still characterized by a constructive role of noise

  5. attitude of secondary school students towards guidance

    African Journals Online (AJOL)

    Elizabeth Egbochuku

    gender and school location significantly influenced students' attitude towards guidance ... students respond and perceive guidance and counselling services will, to ... counsellors will be appointed in post-primary institutions and tertiary levels.

  6. Synchrobetatron resonances

    International Nuclear Information System (INIS)

    1977-03-01

    At the 1975 Particle Accelerator Conference it was reported that a class of resonances were observed in SPEAR II that had not appeared before in SPEAR I. While the existence of sideband resonances of the main betatron oscillation frequencies has been previously observed and analyzed, the resonances observed in SPEAR do not appear to be of the same variety. Experiments were performed at SPEAR to identify the mechanism believed to be the most likely explanation. Some of the current experimental knowledge and theoretical views on the source of these resonances are presented

  7. Snake resonances

    International Nuclear Information System (INIS)

    Tepikian, S.

    1988-01-01

    Siberian Snakes provide a practical means of obtaining polarized proton beams in large accelerators. The effect of snakes can be understood by studying the dynamics of spin precession in an accelerator with snakes and a single spin resonance. This leads to a new class of energy independent spin depolarizing resonances, called snake resonances. In designing a large accelerator with snakes to preserve the spin polarization, there is an added constraint on the choice of the vertical betatron tune due to the snake resonances. 11 refs., 4 figs

  8. Review of soil contamination guidance

    International Nuclear Information System (INIS)

    Mueller, M.A.; Kennedy, W.E. Jr.; Soldat, J.K.

    1981-08-01

    A review of existing and proposed radioactive soil contamination standards and guidance was conducted for United Nuclear Corporation (UNC), Office of Surplus Facilities Management. Information was obtained from both government agencies and other sources during a literature survey. The more applicable standards were reviewed, evaluated, and summarized. Information pertaining to soil contamination for both facility operation and facility decommissioning was obtained from a variety of sources. These sources included: the Code of Federal Regulations, regulatory guides, the Federal Register, topical reports written by various government agencies, topical reports written by national laboratories, and publications from the American National Standards Institute (ANSI). It was difficult to directly compare the standards and guidance obtained from these sources since each was intended for a specific situation and different units or bases were used. However, most of the information reviewed was consistent with the philosophy of maintaining exposures at levels as low as reasonably achievable

  9. Guidance on future art commissioning.

    Science.gov (United States)

    2009-05-01

    Delegates at Building Better Healthcare's recent "National Patient Environment and the Arts Conference 2009" in London heard how national public arts think tank ixia has appointed Bristol-based arts and wellbeing development agency Willis Newson to write "concise and convincing guidance" on commissioning art for new healthcare facilities. A key message, during a joint presentation, was that integrating artwork into hospitals and other healthcare premises requires the earliest possible consideration to reap the maximum rewards.

  10. Current materiality guidance for auditors

    OpenAIRE

    McKee, Thomas E.; Eilifsen, Aasmund

    2000-01-01

    Auditors have to make materiality judgments on every audit. This is a difficult process, as both quantitative and qualitative factors have to be evaluated. Additionally, there is no formal guidance for how to implement the materiality concepts discussed in the auditing standards. Although they are sometimes difficult to make, good materiality judgments are crucial for the conduct of a successful audit as poor judgments can result in an audit that is ineffective and/or inefficient. This report...

  11. 2011 Army Strategic Planning Guidance

    Science.gov (United States)

    2011-03-25

    TESI ) of 22,000 Soldiers, the Army’s total force by the end of the mid-term period is programmed to be 520K (AC). We will achieve a more...dwell ratios, extending TESI authority to adequately man deploying units and sustain the All-Volunteer Force, right-sizing the generating force, and... TESI Temporary End-Strength Increase WMD Weapons of Mass Destruction 2011 ARMY STRATEGIC PLANNING GUIDANCE Page 19 2011

  12. Vocational guidance in social volunteering

    Directory of Open Access Journals (Sweden)

    Nikolay S. Pryazhnikov

    2017-03-01

    Full Text Available The paper discusses the possibilities and limitations of vocational guidance in the social volunteering system. The essence of volunteer work is closely related with assistance to desperate people in searching for the meaning of living, often coinciding with labour activity that are deemed in terms of “the main matter of life” and “the leading activity”. For adolescents, it is the choice of career, and for adults, it is the work proper (i.e. an essential condition for personal self-realization. The problem of “forced volunteering” for experts in vocational guidance also means that they often have to work voluntarily and unselfishly outside the official guidelines. To clarify the terms «volunteer» and «a person in desperate need of help» the study used the method of analyzing the documents, e.g. the Regulations on Social Volunteering, the generalization of psychological sources, the initial survey of university students as active supporters of the volunteer movement, On the essence of volunteering and the place of career guidance in selfless social work. Vocational guidance is not excluded from the general system of volunteerism, but has an insufficiently defined status and low popularity among participants in social volunteering. Also, the problem of «forced volunteering» of experts in career counseling, which often requires voluntary and unselfish performance of quality work outside the framework of official instructions, is also indicated. Simultaneously, positive aspects of such disinterested career initiatives are noted, in particular, less control by the official inspectors (or customers and, accordingly, greater freedom of creativity than when someone else does the work.

  13. Visual guidance of mobile platforms

    Science.gov (United States)

    Blissett, Rodney J.

    1993-12-01

    Two systems are described and results presented demonstrating aspects of real-time visual guidance of autonomous mobile platforms. The first approach incorporates prior knowledge in the form of rigid geometrical models linking visual references within the environment. The second approach is based on a continuous synthesis of information extracted from image tokens to generate a coarse-grained world model, from which potential obstacles are inferred. The use of these techniques in workplace applications is discussed.

  14. Individual plant examination: Submittal guidance

    International Nuclear Information System (INIS)

    1989-08-01

    Based on a Policy Statement on Severe Accidents Regarding Future Designs and Existing Plants, the performance of a plant examination is requested from the licensee of each nuclear power plant. The plant examination looks for vulnerabilities to severe accidents and cost-effective safety improvements that reduce or eliminate the important vulnerabilities. This document delineates guidance for reporting the results of that plant examination. 38 refs., 2 tabs

  15. Quality Assurance in University Guidance Services

    Science.gov (United States)

    Simon, Alexandra

    2014-01-01

    In Europe there is no common quality assurance framework for the delivery of guidance in higher education. Using a case study approach in four university career guidance services in England, France and Spain, this article aims to study how quality is implemented in university career guidance services in terms of strategy, standards and models,…

  16. Providing Career Guidance for Young Women.

    Science.gov (United States)

    Colby, Pamela G.

    This module is directed at personnel working or planning to work in the areas of guidance, counseling, placement and follow-through in junior and senior high school settings, grades 7-12. The module topic is career guidance for young women of junior and senior high school age, aand the focus will be on providing nonbiased career guidance which…

  17. Radionuclide Data Quality Evaluation Guidance

    International Nuclear Information System (INIS)

    Tucker, B.J.; Winters, M.S.; Evans, D.

    2009-01-01

    A considerable amount of radioanalytical data is generated during various phases of the characterization and remediation of radiologically-contaminated sites and properties. It is critical that data generated from the analysis of collected samples be to a level of quality usable by the project and acceptable to stakeholders. In July 2004, the final version of a multi-agency guidance manual entitled Multi-Agency Radiological Analytical Protocols Manual (MARLAP) was issued by the Environmental Protection Agency, Department of Energy, Department of Homeland Security, Nuclear Regulatory Commission, Department of Defense, National Institute of Standards and Technology, U. S. Geological Survey, Food and Drug Administration, and the States of Kentucky and California. The authors' purpose is to introduce readers to some key elements of MARLAP as it relates to radioanalytical lab quality control, and to demonstrate how these guidance elements can be effectively incorporated into mature radioanalytical lab operations and data validation regimes. Based upon the logic and statistical methodologies presented in MARLAP, the authors have revised existing project-specific Radioanalytical Data Evaluation Guidance (RadDEG) used at the FUSRAP Maywood Site in Maywood, NJ. The RadDEG allows users to qualify data in a meaningful way by tying the usability of the data to its activity and uncertainty relative to project action levels and QC results. This exercise may be useful to other projects looking to implement a MARLAP-based approach into their project/site-specific data evaluation methodologies. (authors)

  18. Advances in mechanical detection of magnetic resonance

    International Nuclear Information System (INIS)

    Kuehn, Seppe; Hickman, Steven A.; Marohn, John A.

    2008-01-01

    The invention and initial demonstration of magnetic resonance force microscopy (MRFM) in the early 1990s launched a renaissance of mechanical approaches to detecting magnetic resonance. This article reviews progress made in MRFM in the last decade, including the demonstration of scanned probe detection of magnetic resonance (electron spin resonance, ferromagnetic resonance, and nuclear magnetic resonance) and the mechanical detection of electron spin resonance from a single spin. Force and force-gradient approaches to mechanical detection are reviewed and recent related work using attonewton sensitivity cantilevers to probe minute fluctuating electric fields near surfaces is discussed. Given recent progress, pushing MRFM to single proton sensitivity remains an exciting possibility. We will survey some practical and fundamental issues that must be resolved to meet this challenge.

  19. Nonlinear resonances

    CERN Document Server

    Rajasekar, Shanmuganathan

    2016-01-01

    This introductory text presents the basic aspects and most important features of various types of resonances and anti-resonances in dynamical systems. In particular, for each resonance, it covers the theoretical concepts, illustrates them with case studies, and reviews the available information on mechanisms, characterization, numerical simulations, experimental realizations, possible quantum analogues, applications and significant advances made over the years. Resonances are one of the most fundamental phenomena exhibited by nonlinear systems and refer to specific realizations of maximum response of a system due to the ability of that system to store and transfer energy received from an external forcing source. Resonances are of particular importance in physical, engineering and biological systems - they can prove to be advantageous in many applications, while leading to instability and even disasters in others. The book is self-contained, providing the details of mathematical derivations and techniques invo...

  20. 78 FR 4848 - Social Media: Consumer Compliance Risk Management Guidance

    Science.gov (United States)

    2013-01-23

    ...: Consumer Compliance Risk Management Guidance AGENCY: Federal Financial Institutions Examination Council... Media: Consumer Compliance Risk Management Guidance'' (guidance). Upon completion of the guidance, and... management practices adequately address the consumer compliance and legal risks, as well as related risks...

  1. Guidance on accidents involving radioactivity

    International Nuclear Information System (INIS)

    1989-01-01

    This annex contains advice to Health Authorities on their response to accidents involving radioactivity. The guidance is in six parts:-(1) planning the response required to nuclear accidents overseas, (2) planning the response required to UK nuclear accidents a) emergency plans for nuclear installations b) nuclear powered satellites, (3) the handling of casualties contaminated with radioactive substances, (4) background information for dealing with queries from the public in the event of an accident, (5) the national arrangements for incident involving radioactivity (NAIR), (6) administrative arrangements. (author)

  2. Advantages of computed tomographic guidance

    International Nuclear Information System (INIS)

    Casola, G.; Vansonnenberg, E.

    1987-01-01

    Both ultrasound and CT are successfully used to guide interventional procedures throughout the body. There are advantages and disadvantages to each modality and choosing one over the other will vary from case to case. Major factors influencing choice are discussed in this paper. As a general rule CT guidance is usually required for lesions in the thorax, the adrenals, the pancreas, lymph nodes, and for percutaneous abscess drainage. The authors feel that a complimentary use of ultrasound and CT is essential to optimize success and cost-effectiveness; therefore, the interventional radiologist should be familiar with both imaging modalities

  3. Agent Based Individual Traffic guidance

    DEFF Research Database (Denmark)

    Wanscher, Jørgen Bundgaard

    2004-01-01

    When working with traffic planning or guidance it is common practice to view the vehicles as a combined mass. >From this models are employed to specify the vehicle supply and demand for each region. As the models are complex and the calculations are equally demanding the regions and the detail...... of the road network is aggregated. As a result the calculations reveal only what the mass of vehicles are doing and not what a single vehicle is doing. This is the crucial difference to ABIT (Agent Based Individual Trafficguidance). ABIT is based on the fact that information on the destination of each vehicle...

  4. Laser guidance of mesoscale particles

    Science.gov (United States)

    Underdown, Frank Hartman, Jr.

    Mesoscale particles are guided and trapped in hollow optical fibers using radiation pressure forces. Laser light from a 0.4W, 780nm diode laser is guided in a low- loss fiber mode and used to generate the guidance forces. Laser scattering and absorption forces propels particles along the fiber and polarization gradient forces attract them to the fiber's axial center. Using two counter propagating laser beams, inside the fiber, particles can be trapped in three dimensions. Measuring the spring constant of the trap gives the gradient force. This dissertation describes Rayleigh and Mie scattering models for calculating guidance forces. Calculated forces as a function of particle size and composition (i.e. dielectric, semiconductor, and metals) will be presented. For example, under typical experimental conditions 100nm Au particles are guided by a 2 × 10-14 N propulsive force in a water filled fiber. In comparison, the measured force, obtained from the particle's velocity and Stokes' law, is 7.98 × 10-14 N.

  5. Techniques for Interventional MRI Guidance in Closed-Bore Systems.

    Science.gov (United States)

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2018-02-01

    Efficient image guidance is the basis for minimally invasive interventions. In comparison with X-ray, computed tomography (CT), or ultrasound imaging, magnetic resonance imaging (MRI) provides the best soft tissue contrast without ionizing radiation and is therefore predestined for procedural control. But MRI is also characterized by spatial constraints, electromagnetic interactions, long imaging times, and resulting workflow issues. Although many technical requirements have been met over the years-most notably magnetic resonance (MR) compatibility of tools, interventional pulse sequences, and powerful processing hardware and software-there is still a large variety of stand-alone devices and systems for specific procedures only.Stereotactic guidance with the table outside the magnet is common and relies on proper registration of the guiding grids or manipulators to the MR images. Instrument tracking, often by optical sensing, can be added to provide the physicians with proper eye-hand coordination during their navigated approach. Only in very short wide-bore systems, needles can be advanced at the extended arm under near real-time imaging. In standard magnets, control and workflow may be improved by remote operation using robotic or manual driving elements.This work highlights a number of devices and techniques for different interventional settings with a focus on percutaneous, interstitial procedures in different organ regions. The goal is to identify technical and procedural elements that might be relevant for interventional guidance in a broader context, independent of the clinical application given here. Key challenges remain the seamless integration into the interventional workflow, safe clinical translation, and proper cost effectiveness.

  6. White Matter Lesion Progression in LADIS

    DEFF Research Database (Denmark)

    Schmidt, Reinhold; Berghold, Andrea; Jokinen, Hanna

    2012-01-01

    BACKGROUND AND PURPOSE: White matter lesion (WML) progression has been advocated as a surrogate marker in intervention trials on cerebral small vessel disease. We assessed the rate of visually rated WML progression, studied correlations between lesion progression and cognition, and estimated sample...... sizes for clinical trials with pure WML progression vs combined WML progression-cognitive outcomes. METHODS: Those 394 participants of the Leukoaraiosis and Disability Study (LADIS) study with magnetic resonance imaging scanning at baseline and 3-year follow-up were analyzed. WML progression rating...

  7. Progress Report

    DEFF Research Database (Denmark)

    Duer, Karsten

    1999-01-01

    Progress report describing the work carried out by the Danish participant in the ALTSET project in the period January 1999 to July 1999.......Progress report describing the work carried out by the Danish participant in the ALTSET project in the period January 1999 to July 1999....

  8. Progress Report

    Science.gov (United States)

    2018-05-16

    This report summarizes the annual progress of EPA’s Clean Air Markets Programs such as the Acid Rain Program (ARP) and the Cross-State Air Pollution Rule (CSAPR). EPA systematically collects data on emissions, compliance, and environmental effects, these data are highlighted in our Progress Reports.

  9. Theoretical nuclear structure. Progress report for 1997

    International Nuclear Information System (INIS)

    Nazarewicz, W.; Strayer, M.R.

    1997-01-01

    This research effort is directed toward theoretical support and guidance for the fields of radioactive ion beam physics, gamma-ray spectroscopy, and the interface between nuclear structure and nuclear astrophysics. The authors report substantial progress in all these areas. One measure of progress is publications and invited material. The research described here has led to more than 25 papers that are published, accepted, or submitted to refereed journals, and to 25 invited presentations at conferences and workshops

  10. Health Service use of ionising radiations: Guidance

    International Nuclear Information System (INIS)

    1995-01-01

    This booklet gives outline guidance on the use of ionising radiations in the Health Service in the United Kingdom. Extensive reference is made to documents where more detailed information may be found. The guidance covers general advice on the medical use of ionising radiations, statutory requirements, and guidance on selected Health Service issues such as patient identification procedures, information management systems, deviations from prescribed radiation dose, imaging and radiotherapy. (57 references) (U.K.)

  11. Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Sailer, Anna M., E-mail: anni.sailer@mumc.nl; Haan, Michiel W. de, E-mail: m.de.haan@mumc.nl; Graaf, Rick de, E-mail: r.de.graaf@mumc.nl; Zwam, Willem H. van, E-mail: w.van.zwam@mumc.nl [Maastricht University Medical Center, Department of Radiology (Netherlands); Schurink, Geert Willem H., E-mail: gwh.schurink@mumc.nl [Maastricht University Medical Center, Department of Surgery (Netherlands); Nelemans, Patricia J., E-mail: patty.nelemans@maastrichtuniversity.nl [Maastricht University Medical Centre, Department of Epidemiology (Netherlands); Wildberger, Joachim E., E-mail: j.wildberger@mumc.nl; Das, Marco, E-mail: m.das@mumc.nl [Maastricht University Medical Center, Department of Radiology (Netherlands)

    2015-04-15

    PurposeThis study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA).MethodsFusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography.ResultsAverage time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation).ConclusionsFluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.

  12. Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study

    International Nuclear Information System (INIS)

    Sailer, Anna M.; Haan, Michiel W. de; Graaf, Rick de; Zwam, Willem H. van; Schurink, Geert Willem H.; Nelemans, Patricia J.; Wildberger, Joachim E.; Das, Marco

    2015-01-01

    PurposeThis study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA).MethodsFusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography.ResultsAverage time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation).ConclusionsFluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety

  13. Fusion guidance in endovascular peripheral artery interventions: a feasibility study.

    Science.gov (United States)

    Sailer, Anna M; de Haan, Michiel W; de Graaf, Rick; van Zwam, Willem H; Schurink, Geert Willem H; Nelemans, Patricia J; Wildberger, Joachim E; Das, Marco

    2015-04-01

    This study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA). Fusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography. Average time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation). Fluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.

  14. FY2016 Lightweight Materials Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-10-31

    The Lightweight Materials research and development (R&D) area within the DOE Vehicle Technologies Office (VTO) provides support and guidance for many cutting-edge automotive technologies under development. Research focuses on addressing critical barriers to commercializing lightweight materials for passenger and commercial vehicles. This report describes the progress made on the research and development projects funded by the Lightweight Materials area.

  15. ICRP guidance on radioactive waste disposal

    International Nuclear Information System (INIS)

    Cooper, J.R.

    2002-01-01

    The International Commission on Radiological Protection (ICRP) issued recommendations for a system of radiological protection in 1991 as the 1990 Recommendations. Guidance on the application of these recommendations in the general area of waste disposal was issued in 1997 as Publication 77 and guidance specific to disposal of solid long-lived radioactive waste was issued as Publication 81. This paper summarises ICRP guidance in radiological protection requirements for waste disposal concentrating on the ones of relevance to the geological disposal of solid radioactive waste. Suggestions are made for areas where further work is required to apply the ICRP guidance. (author)

  16. Widening opportunities for career guidance

    DEFF Research Database (Denmark)

    Poulsen, Bo Klindt; Skovhus, Randi Boelskifte; Thomsen, Rie

    2017-01-01

    This chapter discusses research circles as a way of organising collaboration between career guidance researchers and practitioners. Such collaboration, it is argued, helps resist neoliberal governance mechanisms and supports social justice perspectives among teachers involved in the provision...... of career education in Danish schools. Based on a research and development project on career education, case analysis is used to explore research circles as a means for collaboration between researchers and practitioners. This analysis shows that research circles provide teachers with a space to reflect...... both in and on action. Career education is the key focus of the case presented in this chapter and it is argued that, in order to increase social mobility through education, there is a need to widen opportunities through experience-based activities among pupils in Danish schools. The chapter contends...

  17. Widening opportunities for career guidance

    DEFF Research Database (Denmark)

    Poulsen, Bo Klindt; Skovhus, Randi Boelskifte; Thomsen, Rie

    2018-01-01

    This chapter discusses research circles as a way of organising collaboration between career guidance researchers and practitioners. Such collaboration, it is argued, helps resist neoliberal governance mechanisms and supports social justice perspectives among teachers involved in the provision...... of career education in Danish schools. Based on a research and development project on career education, case analysis is used to explore research circles as a means for collaboration between researchers and practitioners. This analysis shows that research circles provide teachers with a space to reflect...... both in and on action. Career education is the key focus of the case presented in this chapter and it is argued that, in order to increase social mobility through education, there is a need to widen opportunities through experience-based activities among pupils in Danish schools. The chapter contends...

  18. Multiquark Resonances

    CERN Document Server

    Esposito, A.; Polosa, A.D.

    2016-01-01

    Multiquark resonances are undoubtedly experimentally observed. The number of states and the amount of details on their properties has been growing over the years. It is very recent the discovery of two pentaquarks and the confirmation of four tetraquarks, two of which had not been observed before. We mainly review the theoretical understanding of this sector of particle physics phenomenology and present some considerations attempting a coherent description of the so called X and Z resonances. The prominent problems plaguing theoretical models, like the absence of selection rules limiting the number of states predicted, motivate new directions in model building. Data are reviewed going through all of the observed resonances with particular attention to their common features and the purpose of providing a starting point to further research.

  19. Neuroaesthetic Resonance

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2013-01-01

    Neuroaesthetic Resonance emerged from a mature body of patient- centered gesture-control research investigating non-formal rehabilitation via ICT-enhanced-Art to question ‘Aesthetic Resonance’. Motivating participation, ludic engagement, and augmenting physical motion in non-formal (fun) treatment...... sessions are achieved via adaptive action-analyzed activities. These interactive virtual environments are designed to empower patients’ creative and/or playful expressions via digital feedback stimuli. Unconscious self- pushing of limits result from innate distractive mechanisms offered by the alternative...... the unencumbered motion-to-computer-generated activities - ‘Music Making’, ‘Painting’, ‘Robotic’ and ‘Video Game’ control. A focus of this position paper is to highlight how Aesthetic Resonance, in this context, relates to the growing body of research on Neuroaesthetics to evolve Neuroaesthetic Resonance....

  20. The Hedgehog Signalling Pathway in Cell Migration and Guidance: What We Have Learned from Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Sofia J. Araújo

    2015-10-01

    Full Text Available Cell migration and guidance are complex processes required for morphogenesis, the formation of tumor metastases, and the progression of human cancer. During migration, guidance molecules induce cell directionality and movement through complex intracellular mechanisms. Expression of these molecules has to be tightly regulated and their signals properly interpreted by the receiving cells so as to ensure correct navigation. This molecular control is fundamental for both normal morphogenesis and human disease. The Hedgehog (Hh signaling pathway is evolutionarily conserved and known to be crucial for normal cellular growth and differentiation throughout the animal kingdom. The relevance of Hh signaling for human disease is emphasized by its activation in many cancers. Here, I review the current knowledge regarding the involvement of the Hh pathway in cell migration and guidance during Drosophila development and discuss its implications for human cancer origin and progression.

  1. Progressive posterior cortical dysfunction

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    Full Text Available Abstract Progressive posterior cortical dysfunction (PPCD is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal and ventral (occipito-temporal pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction, complete Balint's syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right . Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD.

  2. Progressive posterior cortical dysfunction

    Science.gov (United States)

    Porto, Fábio Henrique de Gobbi; Machado, Gislaine Cristina Lopes; Morillo, Lilian Schafirovits; Brucki, Sonia Maria Dozzi

    2010-01-01

    Progressive posterior cortical dysfunction (PPCD) is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal) and ventral (occipito-temporal) pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction), complete Balint’s syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right. Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD. PMID:29213665

  3. Baryon Resonances

    International Nuclear Information System (INIS)

    Oset, E.; Sarkar, S.; Sun Baoxi; Vicente Vacas, M.J.; Ramos, A.; Gonzalez, P.; Vijande, J.; Martinez Torres, A.; Khemchandani, K.

    2010-01-01

    In this talk I show recent results on how many excited baryon resonances appear as systems of one meson and one baryon, or two mesons and one baryon, with the mesons being either pseudoscalar or vectors. Connection with experiment is made including a discussion on old predictions and recent results for the photoproduction of the Λ(1405) resonance, as well as the prediction of one 1/2 + baryon state around 1920 MeV which might have been seen in the γp→K + Λ reaction.

  4. Guidance for evidence-informed policies about health systems: rationale for and challenges of guidance development.

    Directory of Open Access Journals (Sweden)

    Xavier Bosch-Capblanch

    Full Text Available In the first paper in a three-part series on health systems guidance, Xavier Bosch-Capblanch and colleagues examine how guidance is currently formulated in low- and middle-income countries, and the challenges to developing such guidance.

  5. 78 FR 48175 - Retrospective Review of Draft Guidance Documents Issued Before 2010; Withdrawal of Guidances

    Science.gov (United States)

    2013-08-07

    ... guidances (number 19 through 22), contact the Office of Pharmaceutical Science in CDER. 23. ``Qualifying for... to the pharmaceutical industry. In most cases, FDA has developed other guidances and resources to... guidances: 1. ``Manufacturing, Processing, or Holding Active Pharmaceutical Ingredients''--issued April 1998...

  6. Progressive Business

    DEFF Research Database (Denmark)

    Christiansen, Christian O.

    2016-01-01

    Guest Post to the Society for U.S. Intellectual History Blog. Brief introduction to the book Progressive Business: An Intellectual History of the Role of Business in American Society, Oxford U.P., 2015.......Guest Post to the Society for U.S. Intellectual History Blog. Brief introduction to the book Progressive Business: An Intellectual History of the Role of Business in American Society, Oxford U.P., 2015....

  7. 48 CFR 427.104 - General guidance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false General guidance. 427.104... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS General 427.104 General guidance. As used in FAR part 27, the agency head or agency head designee is the Senior Procurement Executive, except under FAR 27.306(a) and (b...

  8. Driving change : sustainable development action plans Guidance

    OpenAIRE

    Sustainable Development Commission

    2008-01-01

    This guidance builds upon the Sustainable Development Commission’s previous guidance, Getting Started (August 2005), which set out the basic elements that the Sustainable Development Commission would expect to see in a good Sustainable Development Action Plan. Publisher PDF Original published August 2005.

  9. Guidance for performing preliminary assessments under CERCLA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-09-01

    EPA headquarters and a national site assessment workgroup produced this guidance for Regional, State, and contractor staff who manage or perform preliminary assessments (PAs). EPA has focused this guidance on the types of sites and site conditions most commonly encountered. The PA approach described in this guidance is generally applicable to a wide variety of sites. However, because of the variability among sites, the amount of information available, and the level of investigative effort required, it is not possible to provide guidance that is equally applicable to all sites. PA investigators should recognize this and be aware that variation from this guidance may be necessary for some sites, particularly for PAs performed at Federal facilities, PAs conducted under EPA`s Environmental Priorities Initiative (EPI), and PAs at sites that have previously been extensively investigated by EPA or others. The purpose of this guidance is to provide instructions for conducting a PA and reporting results. This guidance discusses the information required to evaluate a site and how to obtain it, how to score a site, and reporting requirements. This document also provides guidelines and instruction on PA evaluation, scoring, and the use of standard PA scoresheets. The overall goal of this guidance is to assist PA investigators in conducting high-quality assessments that result in correct site screening or further action recommendations on a nationally consistent basis.

  10. Career Guidance and Public Mental Health

    Science.gov (United States)

    Robertson, Peter J.

    2013-01-01

    Career guidance may have the potential to promote public health by contributing positively to both the prevention of mental health conditions and to population level well-being. The policy implications of this possibility have received little attention. Career guidance agencies are well placed to reach key target groups. Producing persuasive…

  11. Standards for School Guidance Programs in Maryland.

    Science.gov (United States)

    Maryland State Dept. of Education, Baltimore. Div. of Compensatory, Urban, and Supplementary Programs.

    This brochure is a checklist to rate school compliance with the standards for school guidance programs in Maryland, which were developed by the Maryland State Department of Education. The first set of standards addresses the philosophy and goals of school guidance programs in Maryland and the extent to which program goals and objectives are…

  12. HANDBOOK: HAZARDOUS WASTE INCINERATION MEASUREMENT GUIDANCE

    Science.gov (United States)

    This publication, Volume III of the Hazardous Waste Incineration Guidance Series, contains general guidance to permit writers in reviewing hazardous waste incineration permit applications and trial burn plans. he handbook is a how-to document dealing with how incineration measure...

  13. 33 CFR 385.5 - Guidance memoranda.

    Science.gov (United States)

    2010-07-01

    ... ability of the Corps of Engineers, the South Florida Water Management District, and other non-Federal... § 385.5 Guidance memoranda. (a) General. (1) Technical guidance for internal management of Corps of...) General format and content of Project Implementation Reports (§ 385.26(a)); (ii) Instructions for...

  14. Guidance Counsellor Strategies for Handling Bullying

    Science.gov (United States)

    Power-Elliott, Michleen; Harris, Gregory E.

    2012-01-01

    The purpose of this exploratory-descriptive study was to examine how guidance counsellors in the province of Newfoundland and Labrador would handle a specific verbal-relational bullying incident. Also of interest was guidance counsellor involvement and training in bullying programmes and Positive Behaviour Supports. Data for this study was…

  15. Why Guidance Works Better than Punishment.

    Science.gov (United States)

    Gartrell, Dan

    1995-01-01

    Examines how guidance techniques address the full spectrum of intervention methods, from prevention to conflict resolution to long-term management strategies. Discusses how punishment affects both children and teachers. Suggests that to put guidance into practice teachers should: be realistic, tailor activities to each child, practice positive…

  16. 996 RESONANCE November 2013

    Indian Academy of Sciences (India)

    IAS Admin

    996. RESONANCE. November 2013. Page 2. 997. RESONANCE. November 2013. Page 3. 998. RESONANCE. November 2013. Page 4. 999. RESONANCE. November 2013. Page 5. 1000. RESONANCE. November 2013. Page 6. 1001. RESONANCE. November 2013. Page 7. 1002. RESONANCE. November 2013 ...

  17. 817 RESONANCE September 2013

    Indian Academy of Sciences (India)

    IAS Admin

    817. RESONANCE ⎜ September 2013. Page 2. 818. RESONANCE ⎜ September 2013. Page 3. 819. RESONANCE ⎜ September 2013. Page 4. 820. RESONANCE ⎜ September 2013. Page 5. 821. RESONANCE ⎜ September 2013. Page 6. 822. RESONANCE ⎜ September 2013. Page 7. 823. RESONANCE ⎜ September ...

  18. 369 RESONANCE April 2016

    Indian Academy of Sciences (India)

    IAS Admin

    369. RESONANCE ⎜ April 2016. Page 2. 370. RESONANCE ⎜ April 2016. Page 3. 371. RESONANCE ⎜ April 2016. Page 4. 372. RESONANCE ⎜ April 2016. Page 5. 373. RESONANCE ⎜ April 2016. Page 6. 374. RESONANCE ⎜ April 2016. Page 7. 375. RESONANCE ⎜ April 2016.

  19. Ultrasound Guidance for Botulinum Neurotoxin Chemodenervation Procedures

    Directory of Open Access Journals (Sweden)

    Katharine E. Alter

    2017-12-01

    Full Text Available Injections of botulinum neurotoxins (BoNTs are prescribed by clinicians for a variety of disorders that cause over-activity of muscles; glands; pain and other structures. Accurately targeting the structure for injection is one of the principle goals when performing BoNTs procedures. Traditionally; injections have been guided by anatomic landmarks; palpation; range of motion; electromyography or electrical stimulation. Ultrasound (US based imaging based guidance overcomes some of the limitations of traditional techniques. US and/or US combined with traditional guidance techniques is utilized and or recommended by many expert clinicians; authors and in practice guidelines by professional academies. This article reviews the advantages and disadvantages of available guidance techniques including US as well as technical aspects of US guidance and a focused literature review related to US guidance for chemodenervation procedures including BoNTs injection.

  20. Synchrobetatron resonances

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    At the 1975 Particle Accelerator Conference it was reported that a class of resonances were observed in SPEAR II that had not appeared before in SPEAR I. These resonances occur when the betatron oscillation wave numbers ν/sub x/ or ν/sub y/ and the synchrotron wave number ν/sub s/ satisfy the relation (ν/sub x,y/ - mν/sub s/) = 5, with m an integer denoting the m/sup th/ satellite. The main difference between SPEAR II and SPEAR I is the value of ν/sub s/, which in SPEAR II is approximately 0.04, an order of magnitude larger than in SPEAR I. An ad hoc meeting was held at the 1975 Particle Accelerator Conference, where details of the SPEAR II results were presented and various possible mechanisms for producing these resonances were discussed. Later, experiments were performed at SPEAR to identify the mechanism believed to be the most likely explanation. Some of the current experimental knowledge and theoretical views on the source of these resonances are presented

  1. Autostereogram resonators

    Science.gov (United States)

    Leavey, Sean; Rae, Katherine; Murray, Adam; Courtial, Johannes

    2012-09-01

    Autostereograms, or "Magic Eye" pictures, are repeating patterns designed to give the illusion of depth. Here we discuss optical resonators that create light patterns which, when viewed from a suitable position by a monocular observer, are autostereograms of the three-dimensional shape of one of the mirror surfaces.

  2. Optofluidic control of axonal guidance

    Science.gov (United States)

    Gu, Ling; Ordonez, Simon; Black, Bryan; Mohanty, Samarendra K.

    2013-03-01

    Significant efforts are being made for control on axonal guidance due to its importance in nerve regeneration and in the formation of functional neuronal circuitry in-vitro. These include several physical (topographic modification, optical force, and electric field), chemical (surface functionalization cues) and hybrid (electro-chemical, photochemical etc) methods. Here, we report comparison of the effect of linear flow versus microfluidic flow produced by an opticallydriven micromotor in guiding retinal ganglion axons. A circularly polarized laser tweezers was used to hold, position and spin birefringent calcite particle near growth cone, which in turn resulted in microfluidic flow. The flow rate and resulting shear-force on axons could be controlled by a varying the power of the laser tweezers beam. The calcite particles were placed separately in one chamber and single particle was transported through microfluidic channel to another chamber containing the retina explant. In presence of flow, the turning of axons was found to strongly correlate with the direction of flow. Turning angle as high as 90° was achieved. Optofluidic-manipulation can be applied to other types of mammalian neurons and also can be extended to stimulate mechano-sensing neurons.

  3. The European Research Agenda for career guidance and counseling - and beyond. ECADOC - Early stage researchers symposium 2016

    DEFF Research Database (Denmark)

    Thomsen, Rie; Weber, Peter C.

    Research in CGC is an expanding field of research still it is important to attract doctoral candidates to commit themselves to participation in scholarly exchange at central conferences. IAEVG is a central conference to the research field of Career Guidance and Counseling. With this symposium we...... to present their research in progress and to open up for discussion on the inclusion process into the research field of CGC. The Early stage researchers symposium 2016 includes work in progress presentations 1) the European Research Agenda 2) recognition in adult education and the role of guidance, 3......) quality in career guidance, 4) an ESR experience of entering the CGC research community. The symposium will support and encourage Early stage researchers participation in the international career guidance research community and allow for symposium participants to hear about the newest research ideas...

  4. Nuclear theory. 1998 progress report

    International Nuclear Information System (INIS)

    1998-01-01

    Summaries of progress made on the following topics are given: (1) nonresonant contributions to inelastic N→Δ(1232) parity violation; (2) neutron distribution effects in elastic nuclear parity violation; (3) Wilson RG for scalar-plus-fermion field theories at finite density; (4) Perturbation theory for spin ladders using angular momentum coupled bases; (5) mean-field theory for spin ladders using angular momentum density; (6) finite temperature renormalization group effective potentials for the linear Sigma model; (7) negative-parity baryon resonances from lattice QCD; (8) the N→Δ electromagnetic transition amplitudes from QCD sum rules; and (9) higher nucleon resonances in exclusive reactions (γ, πN) on nuclei

  5. Optimal guidance law in quantum mechanics

    International Nuclear Information System (INIS)

    Yang, Ciann-Dong; Cheng, Lieh-Lieh

    2013-01-01

    Following de Broglie’s idea of a pilot wave, this paper treats quantum mechanics as a problem of stochastic optimal guidance law design. The guidance scenario considered in the quantum world is that an electron is the flight vehicle to be guided and its accompanying pilot wave is the guidance law to be designed so as to guide the electron to a random target driven by the Wiener process, while minimizing a cost-to-go function. After solving the stochastic optimal guidance problem by differential dynamic programming, we point out that the optimal pilot wave guiding the particle’s motion is just the wavefunction Ψ(t,x), a solution to the Schrödinger equation; meanwhile, the closed-loop guidance system forms a complex state–space dynamics for Ψ(t,x), from which quantum operators emerge naturally. Quantum trajectories under the action of the optimal guidance law are solved and their statistical distribution is shown to coincide with the prediction of the probability density function Ψ ∗ Ψ. -- Highlights: •Treating quantum mechanics as a pursuit-evasion game. •Reveal an interesting analogy between guided flight motion and guided quantum motion. •Solve optimal quantum guidance problem by dynamic programming. •Gives a formal proof of de Broglie–Bohm’s idea of a pilot wave. •The optimal pilot wave is shown to be a wavefunction solved from Schrödinger equation

  6. Optimal guidance law in quantum mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ciann-Dong, E-mail: cdyang@mail.ncku.edu.tw; Cheng, Lieh-Lieh, E-mail: leo8101@hotmail.com

    2013-11-15

    Following de Broglie’s idea of a pilot wave, this paper treats quantum mechanics as a problem of stochastic optimal guidance law design. The guidance scenario considered in the quantum world is that an electron is the flight vehicle to be guided and its accompanying pilot wave is the guidance law to be designed so as to guide the electron to a random target driven by the Wiener process, while minimizing a cost-to-go function. After solving the stochastic optimal guidance problem by differential dynamic programming, we point out that the optimal pilot wave guiding the particle’s motion is just the wavefunction Ψ(t,x), a solution to the Schrödinger equation; meanwhile, the closed-loop guidance system forms a complex state–space dynamics for Ψ(t,x), from which quantum operators emerge naturally. Quantum trajectories under the action of the optimal guidance law are solved and their statistical distribution is shown to coincide with the prediction of the probability density function Ψ{sup ∗}Ψ. -- Highlights: •Treating quantum mechanics as a pursuit-evasion game. •Reveal an interesting analogy between guided flight motion and guided quantum motion. •Solve optimal quantum guidance problem by dynamic programming. •Gives a formal proof of de Broglie–Bohm’s idea of a pilot wave. •The optimal pilot wave is shown to be a wavefunction solved from Schrödinger equation.

  7. Resonating Statements

    DEFF Research Database (Denmark)

    Hjelholt, Morten; Jensen, Tina Blegind

    2015-01-01

    IT projects are often complex arrangements of technological components, social actions, and organizational transformation that are difficult to manage in practice. This paper takes an analytical discourse perspective to explore the process of legitimizing IT projects. We introduce the concept...... of resonating statements to highlight how central actors navigate in various discourses over time. Particularly, the statements and actions of an IT project manager are portrayed to show how individuals can legitimize actions by connecting statements to historically produced discourses. The case study...... as part of a feedback loop to re-attach the localized IT project to the broader national discourse. The paper concludes with reflections on how to actively build on resonating statements as a strategic resource for legitimizing IT projects...

  8. International guidance, evolution and trends

    International Nuclear Information System (INIS)

    Ruiz Lopez, C.

    2010-01-01

    Carmen Ruiz Lopez, (CSN) addressed the evolution of some of the fundamental concepts related to the objective of protecting future generations, with the intention of encouraging the discussion, and to determine whether the recent international guidance implied any change in philosophy and approach regarding the practical interpretation and implementation of such fundamental concepts. C. Ruiz presented a general overview of the ICRP and IAEA guidance developments as well as the major changes or reorientations introduced by the latest ICRP Recommendations and IAEA Safety Standards that are relevant to long-term issues of geological disposal, namely, ICRP 103 (2009), ICRP 101 (2006), IAEA Safety Fundamentals SF-1(2006) and WS-R-4. As for the ICRP developments, ICRP 103 confirms the validity of ICRP 81(1998) as the main ICRP reference for long-lived waste disposal. C. Ruiz then noted the extension of the scope of ICPR 81 mentioning some of the principles and recommendations related to the objective of protecting future generations and the view of the Commission for demonstrating compliance. ICRP 103 and ICRP 101 reinforce the importance of transparency in the decision-making process and in the demonstration of confidence in situations of increasing uncertainties about time, giving more weight to the process itself and strengthening the need for an open dialogue between regulator and implementer. In both recommendations the Commission recognises the influence of societal values in the final decision on the level of radiological protection, as well as the influence of social concerns and political aspects in the decision-making process. The evolution of internationally agreed safety fundamental objectives and principles can be observed in the changes from the IAEA's Waste Safety Fundamentals of 1995 to the new Safety Fundamentals of 2006. C Ruiz presented a comparison of both documents focussing on the differences in dealing with fundamental concepts related to the

  9. Assessment of the effectiveness of guidance services in senior ...

    African Journals Online (AJOL)

    Guidance Service Assessment Questionnaire for Teacher/Students (GSAQTS) was used to measure the extent of guidance services and their perception of it. ... to counsellor, and a misconception of the counsellors role has made guidance ...

  10. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  11. Online thesis guidance management information system

    Science.gov (United States)

    Nasution, T. H.; Pratama, F.; Tanjung, K.; Siregar, I.; Amalia, A.

    2018-03-01

    The development of internet technology in education is still not maximized, especially in the process of thesis guidance between students and lecturers. Difficulties met the lecturers to help students during thesis guidance is the limited communication time and the compatibility of schedule between students and lecturer. To solve this problem, we designed an online thesis guidance management information system that helps students and lecturers to do thesis tutoring process anytime, anywhere. The system consists of a web-based admin app for usage management and an android-based app for students and lecturers.

  12. Gravitoelectromagnetic resonances

    International Nuclear Information System (INIS)

    Tsagas, Christos G.

    2011-01-01

    The interaction between gravitational and electromagnetic radiation has a rather long research history. It is well known, in particular, that gravity-wave distortions can drive propagating electromagnetic signals. Since forced oscillations provide the natural stage for resonances to occur, gravitoelectromagnetic resonances have been investigated as a means of more efficient gravity-wave detection methods. In this report, we consider the coupling between the Weyl and the Maxwell fields on a Minkowski background, which also applies to astrophysical environments where gravity is weak, at the second perturbative level. We use covariant methods that describe gravitational waves via the transverse component of the shear, instead of pure-tensor metric perturbations. The aim is to calculate the properties of the electromagnetic signal, which emerges from the interaction of its linear counterpart with an incoming gravitational wave. Our analysis shows how the wavelength and the amplitude of the gravitationally driven electromagnetic wave vary with the initial conditions. More specifically, for certain initial data, the amplitude of the induced electromagnetic signal is found to diverge. Analogous, diverging, gravitoelectromagnetic resonances were also reported in cosmology. Given that, we extend our Minkowski space study to cosmology and discuss analogies and differences in the physics and in the phenomenology of the Weyl-Maxwell coupling between the aforementioned two physical environments.

  13. Magnetic resonance annual 1986

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1986-01-01

    This book contains papers written on magnetic resonance during 1986. Topics include: musculosketetal magnetic resonance imaging; imaging of the spine; magnetic resonance chemical shift imaging; magnetic resonance imaging in the central nervous system; comparison to computed tomography; high resolution magnetic resonance imaging using surface coils; magnetic resonance imaging of the chest; magnetic resonance imaging of the breast; magnetic resonance imaging of the liver; magnetic resonance spectroscopy of neoplasms; blood flow effects in magnetic resonance imaging; and current and potential applications of clinical sodium magnetic resonance imaging

  14. 1004 RESONANCE November 2013

    Indian Academy of Sciences (India)

    IAS Admin

    1004. RESONANCE │ November 2013. Page 2. 1005. RESONANCE │ November 2013. Page 3. 1006. RESONANCE │ November 2013. Page 4. 1007. RESONANCE │ November 2013. Page 5. 1008. RESONANCE │ November 2013. Page 6. 1009. RESONANCE │ November 2013. Page 7. 1010. RESONANCE ...

  15. Even order snake resonances

    International Nuclear Information System (INIS)

    Lee, S.Y.

    1993-01-01

    We found that the perturbed spin tune due to the imperfection resonance plays an important role in beam depolarization at snake resonances. We also found that even order snake resonances exist in the overlapping intrinsic and imperfection resonances. Due to the perturbed spin tune shift of imperfection resonances, each snake resonance splits into two

  16. Significant Guidance Issued by the Federal Motor Carrier Safety Administration

    Data.gov (United States)

    Department of Transportation — A list of Significant Guidance documents, which include guidance document disseminated to regulated entities or the general public that may reasonably be anticipated...

  17. Significant Guidance Issued by the Federal Transit Administration

    Data.gov (United States)

    Department of Transportation — A list of Significant Guidance documents, which include guidance document disseminated to regulated entities or the general public that may reasonably be anticipated...

  18. Significant Guidance Issued by the Federal Aviation Administration

    Data.gov (United States)

    Department of Transportation — A list of Significant Guidance documents, which include guidance document disseminated to regulated entities or the general public that may reasonably be anticipated...

  19. Significant Guidance Issued by the Federal Highway Administration

    Data.gov (United States)

    Department of Transportation — A list of Significant Guidance documents, which include guidance document disseminated to regulated entities or the general public that may reasonably be anticipated...

  20. European Union Sustainable Purchasing Guidance Profile

    Science.gov (United States)

    To help you find the resource that is right for your organization, EPA conducted a scan of the landscape and developed summary profiles of some of the leading sources of sustainable purchasing guidance around the globe.

  1. Responsible Purchasing Network - Sustainable Purchasing Guidance Profile

    Science.gov (United States)

    To help you find the resource that is right for your organization, EPA conducted a scan of the landscape and developed summary profiles of some of the leading sources of sustainable purchasing guidance around the globe.

  2. Regulatory systems-based licensing guidance documentation

    International Nuclear Information System (INIS)

    Delligatti, M.S.

    1991-01-01

    The US Nuclear Regulatory Commission (NRC) has developed a series of licensing guidance documents based on the regulatory requirements in Part 60 of Title 10 of the Code of Federal Regulations (10 CFR Part 60). This regulatory systems-based approach to licensing guidance documentation relies on the definition of the high-level waste repository in 10 CFR Part 60. A document which is important for the frame-work it gives to other programmatic licensing guidance is the Draft Regulatory Guide open-quotes Format and Content for the License Application for the High-Level Waste Repositoryclose quotes (FCRG). The FCRG describes a format and content acceptable to NRC for a high-level waste repository license application pursuant to the requirements of 10 CFR Part 60. Other licensing guidance documents will be compatible with the FCRG

  3. Nigerian Journal of Guidance and Counselling

    African Journals Online (AJOL)

    The Nigerian Journal of Guidance and Counselling. ... Journal Homepage Image ... by the Department of Counsellor Education, University of Ilorin, Ilorin, Nigeria. ... Awareness and use of Meseron therapy among clinical psychologists in ...

  4. Drill machine guidance using natural occurring radiation

    International Nuclear Information System (INIS)

    Dahl, H.D.; Schroeder, R.L.; Williams, B.J.

    1980-01-01

    A drilling machine guidance system is described which uses only the naturally occuring radiation within the seam or stratum of interest. The apparatus can be used for guiding horizontal drilling machines through coal seams and the like. (U.K.)

  5. Smartphone Video Guidance Sensor for Small Satellites

    Data.gov (United States)

    National Aeronautics and Space Administration — Smartphone Video Guidance Sensor(SVGS) for Small Satellites will provide a low-cost,integrated rendezvous & proximity operations sensor system to allow an...

  6. Moisture Control Guidance for Commercial and Public ...

    Science.gov (United States)

    This document provides guidance to designers, construction mangers, and building operation/maintenance managers to improve IEQ and reduce risks of encountering IEQ problems due to insufficient moisture control. EPA will be producing a document entitled

  7. RCRA Programmatic Information Policy and Guidance

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes program policy and guidance documents that are used by the EPA regions, states, tribes and private parties to implement the hazardous waste...

  8. Construction machine control guidance implementation strategy.

    Science.gov (United States)

    2010-07-01

    Machine Controlled Guidance (MCG) technology may be used in roadway and bridge construction to improve construction efficiencies, potentially resulting in reduced project costs and accelerated schedules. The technology utilizes a Global Positioning S...

  9. Precision Guidance with Impact Angle Requirements

    National Research Council Canada - National Science Library

    Ford, Jason

    2001-01-01

    This paper examines a weapon system precision guidance problem in which the objective is to guide a weapon onto a non-manoeuvring target so that a particular desired angle of impact is achieved using...

  10. Guidance for the national healthcare disparities report

    National Research Council Canada - National Science Library

    Swift, Elaine K

    2002-01-01

    The Agency for Healthcare Research Quality commissioned the Institute of Medicine establish a committee to provide guidance on the National Healthcare Disparities Report is of access to health care...

  11. UV DISINFECTION GUIDANCE MANUAL FOR THE ...

    Science.gov (United States)

    Provides technical information on selection, design and operation of UV systems; provides regulatory agencies with guidance and the necessary tools to assess UV systems at the design, start-up, and routine operation phase; provides manufacturers with the testing and performance standards for UV components and systems for treating drinking water. Provide guidance to water systems, regulators and manufacturers on UV disinfection of drinking water.

  12. A New Approach to Lane Guidance Systems

    OpenAIRE

    Eidehall, Andreas; Pohl, Jochen; Gustafsson, Fredrik

    2005-01-01

    This paper presents a new automotive safety function called Emergency Lane Assist (ELA). ELA combines conventional lane guidance systems with a threat assessment module that tries to activate and deactivate the lane guidance interventions according to the actual risk level of lane departure. The goal is to only prevent dangerous lane departure manoeuvres. Such a threat assessment algorithm is dependent on detailed information about the vehicle surroundings, i.e., positions and motion of other...

  13. Neutron-induced Fission Cross Sections of Am and Cm isotopes (Final Report of Research Contract 14485). Resonance and Fast Neutron Induced Fission Cross Sections of Americium and Curium Nuclides (Third-year Progress Report of Research Contract 14485)

    International Nuclear Information System (INIS)

    Alekseev, A.A.; Bergman, A.A.; Berlev, A.I.; Koptelov, E.A.; Egorov, A.S.; Samylin, B.F.; Trufanov, A.M.; Fursov, B.I.; Shorin, V.S.

    2012-01-01

    The neutron induced fission cross sections of Am and Cm isotopes were measured relative to 239 Pu in the neutron energy range from 1 eV to 20 keV at the INR RAS lead slowing down spectrometer LSDS-100. The fission resonance integrals were also estimated using the measured cross section data. The results have been compared with the available experimental and evaluated data. This analysis has shown the present status of the measured fission cross sections and the necessity to revise the evaluated cross sections libraries for the minor actinides. (author)

  14. Application of image guidance in pituitary surgery

    Science.gov (United States)

    de Lara, Danielle; Filho, Leo F. S. Ditzel; Prevedello, Daniel M.; Otto, Bradley A.; Carrau, Ricardo L.

    2012-01-01

    Background: Surgical treatment of pituitary pathologies has evolved along the years, adding safety and decreasing morbidity related to the procedure. Advances in the field of radiology, coupled with stereotactic technology and computer modeling, have culminated in the contemporary and widespread use of image guidance systems, as we know them today. Image guidance navigation has become a frequently used technology that provides continuous three-dimensional information for the accurate performance of neurosurgical procedures. We present a discussion about the application of image guidance in pituitary surgeries. Methods: Major indications for image guidance neuronavigation application in pituitary surgery are presented and demonstrated with illustrative cases. Limitations of this technology are also presented. Results: Patients presenting a history of previous transsphenoidal surgeries, anatomical variances of the sphenoid sinus, tumors with a close relation to the internal carotid arteries, and extrasellar tumors are the most important indications for image guidance in pituitary surgeries. The high cost of the equipment, increased time of surgery due to setup time, and registration and the need of specific training for the operating room personnel could be pointed as limitations of this technology. Conclusion: Intraoperative image guidance systems provide real-time images, increasing surgical accuracy and enabling safe, minimally invasive interventions. However, the use of intraoperative navigation is not a replacement for surgical experience and a systematic knowledge of regional anatomy. It must be recognized as a tool by which the neurosurgeon can reduce the risk associated with surgical approach and treatment of pituitary pathologies. PMID:22826819

  15. The use of image-guidance during transsphenoidal pituitary surgery in the United States

    Science.gov (United States)

    Chung, Thomas K.; Riley, Kristen O.

    2015-01-01

    Background: Intraoperative image guidance is a useful modality for transsphenoidal pituitary surgery. However, the outcomes associated with this technology have not been systematically evaluated. Objective: The purpose of the study was to quantify complication rates with and without the use of image guidance during transsphenoidal pituitary surgery using a nationwide database with broadly applicable results. Methods: A retrospective analysis of the Nationwide Inpatient Sample was performed from 2007 to 2011. Transsphenoidal pituitary resections for adenomas were identified by International Classification of Diseases-9th Revision, Clinical Modification code. The effect of image guidance on cerebrospinal fluid (CSF) leak complications and cost-benefit was analyzed. Results: A total of 48,848 transsphenoidal pituitary resections were identified, of which 77.5% were partial resections and 22.5% were complete. Pathologic indications included benign (89.3%), malignant primary (0.6%), and malignant secondary (0.4%). Complications included same-stay death (0.4%), CSF leak (8.8%), postoperative CSF rhinorrhea (1.9%), diabetes insipidus (12.4%), and meningitis (0.4%). Image guidance was employed in 7% (n = 3401) of all cases. When analyzed by modality, computed tomography (CT)-assisted procedures had lower CSF rhinorrhea rates (1.1%) compared with cases with no image guidance (1.9%), whereas magnetic resonance (MR)-assisted procedures had the highest rates (2.7%, χ2 p surgery had significantly shorter length of stay (2.9 days) versus no image guidance (3.7 days, p surgery is associated with a lower rate of CSF leak, shorter length of stay, and lower cost compared with patients without image guidance. Further studies that control for severity and extent of disease are warranted to confirm this finding. PMID:25975254

  16. Progressive amusia and aprosody.

    Science.gov (United States)

    Confavreux, C; Croisile, B; Garassus, P; Aimard, G; Trillet, M

    1992-09-01

    We report a case of slowly progressive amusia and aprosody in association with orofacial and eyelid apraxias. The patient was independent in daily living activities. Insight, judgment, and behavior were intact. Her language was normal, and she demonstrated no limb, dressing, or constructional apraxia. She had no prosopagnosia, no visuospatial disturbances, and no memory impairment. Imaging studies (computed tomography, magnetic resonance imaging, single photon emission computed tomography) indicated a selective disorder of the right frontal and temporal regions. Review of the literature shows an increasing number of reports of this degenerative syndrome affecting the left dominant hemisphere and language areas, whereas cases of the syndrome affecting the right hemisphere are rare. To our knowledge, this is the first case in which aprosody and amusia were associated with a focal cortical degeneration.

  17. 1985. Progress annual report

    International Nuclear Information System (INIS)

    1986-06-01

    Tore Supra construction has been vigorously continued. The whole cryogenic system has been entirely delivered. On TFR priority has been given to electron cyclotron resonance heating; but also neutral heating mechanisms, pellet injection, plasma-wall interaction in the presence of pumped limiter, impurity transport and plasma turbulence have been studied and progress on diagnostics have been made. On Petula, with lower hybrid wave, the numerous results on ion heating, current drive, plasma stability in the presence of non-inductive current and on Tore Supra technical problems are important. At last, theoretical and numerical results are concerned with plasma equilibrium macroscopic evolution of plasma, RF heating, plasma instabilities, magnetic islands, turbulence, transport coefficients and spectroscopy [fr

  18. Measuring progress

    DEFF Research Database (Denmark)

    Wahlberg, Ayo

    2007-01-01

    In recent years, sociological examinations of genetics, therapeutic cloning, neuroscience and tissue engineering have suggested that 'life itself' is currently being transformed through technique with profound implications for the ways in which we understand and govern ourselves and others...... in much the same way that mortality rates, life expectancy or morbidity rates can. By analysing the concrete ways in which human progress has been globally measured and taxonomised in the past two centuries or so, I will show how global stratifications of countries according to their states...

  19. Constituent Aspects of Workplace Guidance in Secondary VET

    Science.gov (United States)

    Swager, Robert; Klarus, Ruud; van Merriënboer, Jeroen J. G.; Nieuwenhuis, Loek F. M.

    2015-01-01

    Purpose: This paper aims to present an integrated model of workplace guidance to enhance awareness of what constitutes good guidance, to improve workplace guidance practices in vocational education and training. Design/methodology/approach: To identify constituent aspects of workplace guidance, a systematic search of Web of Science was conducted,…

  20. The Development of a Lifelong Guidance System in Hungary

    Science.gov (United States)

    Watts, A. G.; Borbely-Pecze, Bors Tibor

    2011-01-01

    The development of a lifelong guidance system in Hungary Systematic work is currently being undertaken in Hungary to develop a lifelong guidance system, in line with principles outlined by leading international organisations. The origins of career guidance in Hungary, and the nature of the current career guidance system, are outlined. The main…

  1. Non-Participation in Guidance: An Opportunity for Development?

    Science.gov (United States)

    Thomsen, Rie

    2014-01-01

    This article discusses how new opportunities for guidance can emerge from an analysis of the interplay between the participation (or lack of participation) of the individuals in career guidance, and the career guidance practitioner's response. The article suggests critical psychology as a framework for career guidance research and presents…

  2. Constituent aspects of workplace guidance in secondary VET

    NARCIS (Netherlands)

    Swager, Robert; Klarus, Ruud; Van Merriënboer, Jeroen; Nieuwenhuis, Loek

    2018-01-01

    Purpose – This paper aims to present an integrated model of workplace guidance to enhance awareness of what constitutes good guidance, to improve workplace guidance practices in vocational education and training. Design/methodology/approach – To identify constituent aspects of workplace guidance,

  3. 76 FR 61098 - Guidance for 1-Hour SO2

    Science.gov (United States)

    2011-10-03

    ...Notice is hereby given that the EPA has posted its draft non- binding guidance titled, ``Guidance for 1-Hour SO2 NAAQS SIP Submissions'' on its Web site. The EPA invites public comments on this guidance document during the comment period specified below, and plans to issue an updated version of the guidance after reviewing timely submitted comments.

  4. Guidance and Counselling in the Universal Basic Education ...

    African Journals Online (AJOL)

    Quite a number of personnel has significant and diverse roles to play. The guidance counsellor whose role is to provide indispensable guidance services is the primary focus of this paper. The paper justifies the relevance of guidance services to the UBE scheme and also isolates a number of challenges facing the guidance ...

  5. Progressivity Enhanced

    Directory of Open Access Journals (Sweden)

    Marko Hren

    2013-09-01

    Full Text Available Rather than a scientific text, the author contributes a concise memorandum from the originator of the idea who has managed the campaign for the conversion of the military barracks into a creative cluster between 1988 and 2002, when he parted ways with Metelkova due to conflicting views on the center’s future. His views shed light on a distant period of time from a perspective of a participant–observer. The information is abundantly supported by primary sources, also available online. However, some of the presented hypotheses are heavily influenced by his personal experiences of xenophobia, elitism, and predatorial behavior, which were already then discernible on the so-called alternative scene as well – so much so that they obstructed the implementation of progressive programs. The author claims that, in spite of the substantially different reality today, the myths and prejudices concerning Metelkova must be done away with in order to enhance its progressive nature. Above all, the paper calls for an objective view on internal antagonisms, mainly originating in deep class divisions between the users. These make a clear distinction between truly marginal ndividuals and the overambitious beau-bourgeois, as the author labels the large part of users of Metelkova of »his« time. On these grounds, he argues for a robust approach to ban all forms of xenophobia and self-ghettoization.

  6. Semantic guidance of eye movements in real-world scenes.

    Science.gov (United States)

    Hwang, Alex D; Wang, Hsueh-Cheng; Pomplun, Marc

    2011-05-25

    The perception of objects in our visual world is influenced by not only their low-level visual features such as shape and color, but also their high-level features such as meaning and semantic relations among them. While it has been shown that low-level features in real-world scenes guide eye movements during scene inspection and search, the influence of semantic similarity among scene objects on eye movements in such situations has not been investigated. Here we study guidance of eye movements by semantic similarity among objects during real-world scene inspection and search. By selecting scenes from the LabelMe object-annotated image database and applying latent semantic analysis (LSA) to the object labels, we generated semantic saliency maps of real-world scenes based on the semantic similarity of scene objects to the currently fixated object or the search target. An ROC analysis of these maps as predictors of subjects' gaze transitions between objects during scene inspection revealed a preference for transitions to objects that were semantically similar to the currently inspected one. Furthermore, during the course of a scene search, subjects' eye movements were progressively guided toward objects that were semantically similar to the search target. These findings demonstrate substantial semantic guidance of eye movements in real-world scenes and show its importance for understanding real-world attentional control. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Raising the Profile of Career Guidance: Educational and Vocational Guidance Practitioner

    Science.gov (United States)

    Hiebert, Bryan

    2009-01-01

    In 2007 the International Association for Educational and Vocational Guidance (IAEVG) launched the Educational and Vocational Guidance Practitioner credential (EVGP) as one means of formally acknowledging the knowledge, skills, and personal attributes that practitioners need in order to provide quality career development services to clients. This…

  8. Safety of magnetic fusion facilities: Guidance

    International Nuclear Information System (INIS)

    1996-05-01

    This document provides guidance for the implementation of the requirements identified in DOE-STD-6002-96, Safety of Magnetic Fusion Facilities: Requirements. This guidance is intended for the managers, designers, operators, and other personnel with safety responsibilities for facilities designated as magnetic fusion facilities. While the requirements in DOE-STD-6002-96 are generally applicable to a wide range of fusion facilities, this Standard, DOE-STD-6003-96, is concerned mainly with the implementation of those requirements in large facilities such as the International Thermonuclear Experimental Reactor (ITER). Using a risk-based prioritization, the concepts presented here may also be applied to other magnetic fusion facilities. This Standard is oriented toward regulation in the Department of Energy (DOE) environment as opposed to regulation by other regulatory agencies. As the need for guidance involving other types of fusion facilities or other regulatory environments emerges, additional guidance volumes should be prepared. The concepts, processes, and recommendations set forth here are for guidance only. They will contribute to safety at magnetic fusion facilities

  9. Guidance levels, achievable doses and expectation levels

    International Nuclear Information System (INIS)

    Li, Lianbo; Meng, Bing

    2002-01-01

    The National Radiological Protection Board (NRPB), the International Atomic Energy Agency (IAEA) and the Commission of the European Communities (CEC) published their guidance levels and reference doses for typical X-ray examination and nuclear medicine in their documents in 1993, 1994 and 1996 respectively. From then on, the concept of guidance levels or reference doses have been applied to different examinations in the field of radiology and proved to be effective for reduction of patient doses. But the guidance levels or reference doses are likely to have some shortcomings and can do little to make further reduction of patient dose in the radiology departments where patient dose are already below them. For this reason, the National Radiological Protection Board (NRPB) proposed a concept named achievable doses which are based on the mean dose observed for a selected sample of radiology departments. This paper will review and discuss the concept of guidance levels and achievable doses, and propose a new concept referred to as Expectation Levels that will encourage the radiology departments where patient dose are already below the guidance levels to keep patient dose as low as reasonably achievable. Some examples of the expectation levels based on the data published by a few countries are also illustrated in this paper

  10. Fine Guidance Sensing for Coronagraphic Observatories

    Science.gov (United States)

    Brugarolas, Paul; Alexander, James W.; Trauger, John T.; Moody, Dwight C.

    2011-01-01

    Three options have been developed for Fine Guidance Sensing (FGS) for coronagraphic observatories using a Fine Guidance Camera within a coronagraphic instrument. Coronagraphic observatories require very fine precision pointing in order to image faint objects at very small distances from a target star. The Fine Guidance Camera measures the direction to the target star. The first option, referred to as Spot, was to collect all of the light reflected from a coronagraph occulter onto a focal plane, producing an Airy-type point spread function (PSF). This would allow almost all of the starlight from the central star to be used for centroiding. The second approach, referred to as Punctured Disk, collects the light that bypasses a central obscuration, producing a PSF with a punctured central disk. The final approach, referred to as Lyot, collects light after passing through the occulter at the Lyot stop. The study includes generation of representative images for each option by the science team, followed by an engineering evaluation of a centroiding or a photometric algorithm for each option. After the alignment of the coronagraph to the fine guidance system, a "nulling" point on the FGS focal point is determined by calibration. This alignment is implemented by a fine alignment mechanism that is part of the fine guidance camera selection mirror. If the star images meet the modeling assumptions, and the star "centroid" can be driven to that nulling point, the contrast for the coronagraph will be maximized.

  11. ISR effects for resonant Higgs production at future lepton colliders

    Directory of Open Access Journals (Sweden)

    Mario Greco

    2016-12-01

    Full Text Available We study the effects of the initial state radiation on the s-channel Higgs boson resonant production at μ+μ− and e+e− colliders by convoluting with the beam energy spread profile of the collider and the Breit–Wigner resonance profile of the signal. We assess their impact on both the Higgs signal and SM backgrounds for the leading decay channels h→bb¯, WW⁎. Our study improves the existing analyses of the proposed future resonant Higgs factories and provides further guidance for the accelerator designs with respect to the physical goals.

  12. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1980-01-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (author)

  13. Applied neutron resonance theory

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1978-07-01

    Utilisation of resonance theory in basic and applications-oriented neutron cross section work is reviewed. The technically important resonance formalisms, principal concepts and methods as well as representative computer programs for resonance parameter extraction from measured data, evaluation of resonance data, calculation of Doppler-broadened cross sections and estimation of level-statistical quantities from resonance parameters are described. (orig.) [de

  14. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  15. 2nd CEAS Specialist Conference on Guidance, Navigation and Control

    CERN Document Server

    Mulder, Bob; Choukroun, Daniel; Kampen, Erik-Jan; Visser, Coen; Looye, Gertjan

    2013-01-01

    Following the successful 1st CEAS (Council of European Aerospace Societies) Specialist Conference on Guidance, Navigation and Control (CEAS EuroGNC) held in Munich, Germany in 2011, Delft University of Technology happily accepted the invitation of organizing the 2nd  CEAS EuroGNC in Delft, The Netherlands in 2013. The goal of the conference is to promote new advances in aerospace GNC theory and technologies for enhancing safety, survivability, efficiency, performance, autonomy and intelligence of aerospace systems using on-board sensing, computing and systems. A great push for new developments in GNC are the ever higher safety and sustainability requirements in aviation. Impressive progress was made in new research fields such as sensor and actuator fault detection and diagnosis, reconfigurable and fault tolerant flight control, online safe flight envelop prediction and protection, online global aerodynamic model identification, online global optimization and flight upset recovery. All of these challenges de...

  16. Pollution prevention opportunity assessments. Guidance for the Hanford Site

    International Nuclear Information System (INIS)

    Engel, J.A.

    1994-10-01

    The purpose of this document is to provide help to you, Hanford waste generators, in finding ways to reduce waste through Pollution Prevention (P2) and Pollution Prevention Opportunity Assessments (P2OAs). It is based on guidance from other sites, and serves to compliment the Hanford-specific training on P2OAs offered by the Pollution Prevention group at Westinghouse Hanford Company (WHC). The chapters of this document include help on how to choose major waste generating activities, how to conduct a P2OA, how to get results, and how to show progress. There is also a chapter on special situations and problems your facility may encounter. This first chapter tells you why you should consider conducting P2OAs and why they may be required

  17. 75 FR 69089 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2010-11-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0514] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document... Administration (FDA) is announcing the availability of the guidance entitled ``Class II Special Controls Guidance...

  18. 76 FR 29251 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls; Guidance...

    Science.gov (United States)

    2011-05-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2006-D-0094] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls; Guidance Document... of the guidance entitled ``Guidance for Industry and Food and Drug Administration Staff; Class II...

  19. Measuring Integrated Socioemotional Guidance at School: Factor Structure and Reliability of the Socioemotional Guidance Questionnaire (SEG-Q)

    Science.gov (United States)

    Jacobs, Karen; Struyf, Elke

    2013-01-01

    Socioemotional guidance of students has recently become an integral part of education, however no instrument exists to measure integrated socioemotional guidance. This study therefore examines the factor structure and reliability of the Socioemotional Guidance Questionnaire. Psychometric properties of the Socioemotional Guidance Questionnaire and…

  20. Automated low-thrust guidance for the orbital maneuvering vehicle

    Science.gov (United States)

    Rose, Richard E.; Schmeichel, Harry; Shortwell, Charles P.; Werner, Ronald A.

    1988-01-01

    This paper describes the highly autonomous OMV Guidance Navigation and Control system. Emphasis is placed on a key feature of the design, the low thrust guidance algorithm. The two guidance modes, orbit change guidance and rendezvous guidance, are discussed in detail. It is shown how OMV will automatically transfer from its initial orbit to an arbitrary target orbit and reach a specified rendezvous position relative to the target vehicle.

  1. 76 FR 66925 - Guidance for 1-Hour SO2

    Science.gov (United States)

    2011-10-28

    ...The EPA is announcing an extension of the public comment period for its draft non-binding guidance titled, ``Guidance for 1-Hour SO2 SIP Submissions.'' The draft of the guidance document is currently on the EPA's Web site. The EPA is extending the comment period for an additional 30-day period and invites public comments on this guidance during this period. The EPA plans to issue an updated version of the guidance after reviewing timely submitted comments.

  2. Amending the Characterization of Guidance in Visual Analytics

    OpenAIRE

    Ceneda, Davide; Gschwandtner, Theresia; May, Thorsten; Miksch, Silvia; Schulz, Hans-Jörg; Streit, Marc; Tominski, Christian

    2017-01-01

    At VAST 2016, a characterization of guidance has been presented. It includes a definition of guidance and a model of guidance based on van Wijk's model of visualization. This note amends the original characterization of guidance in two aspects. First, we provide a clarification of what guidance actually is (and is not). Second, we insert into the model a conceptually relevant link that was missing in the original version.

  3. Recent progress in medical imaging technology

    International Nuclear Information System (INIS)

    Endo, Masahiro

    2004-01-01

    Medical imaging is name of methods for diagnosis and therapy, which make visible with physical media such as X-ray, structures and functions of man's inside those are usually invisible. These methods are classified by the physical media into ultrasound imaging, magnetic resonance imaging, nuclear medicine imaging and X-ray imaging etc. Having characteristics different from one another, these are used complementarily in medical fields though in some case being competitive. Medical imaging is supported by highly progressed technology, which is called medical imaging technology. This paper describes a survey of recent progress of medical imaging technology in magnetic resonance imaging, nuclear medicine imaging and X-ray imaging. (author)

  4. HUMAN FACTORS GUIDANCE FOR CONTROL ROOM EVALUATION

    International Nuclear Information System (INIS)

    OHARA, J.; BROWN, W.; STUBLER, W.; HIGGINS, J.; WACHTEL, J.; PERSENSKY, J.J.

    2000-01-01

    The Human-System Interface Design Review Guideline (NUREG-0700, Revision 1) was developed by the US Nuclear Regulatory Commission (NRC) to provide human factors guidance as a basis for the review of advanced human-system interface technologies. The guidance consists of three components: design review procedures, human factors engineering guidelines, and a software application to provide design review support called the ''Design Review Guideline.'' Since it was published in June 1996, Rev. 1 to NUREG-0700 has been used successfully by NRC staff, contractors and nuclear industry organizations, as well as by interested organizations outside the nuclear industry. The NRC has committed to the periodic update and improvement of the guidance to ensure that it remains a state-of-the-art design evaluation tool in the face of emerging and rapidly changing technology. This paper addresses the current research to update of NUREG-0700 based on the substantial work that has taken place since the publication of Revision 1

  5. GUIDANCE2: accurate detection of unreliable alignment regions accounting for the uncertainty of multiple parameters.

    Science.gov (United States)

    Sela, Itamar; Ashkenazy, Haim; Katoh, Kazutaka; Pupko, Tal

    2015-07-01

    Inference of multiple sequence alignments (MSAs) is a critical part of phylogenetic and comparative genomics studies. However, from the same set of sequences different MSAs are often inferred, depending on the methodologies used and the assumed parameters. Much effort has recently been devoted to improving the ability to identify unreliable alignment regions. Detecting such unreliable regions was previously shown to be important for downstream analyses relying on MSAs, such as the detection of positive selection. Here we developed GUIDANCE2, a new integrative methodology that accounts for: (i) uncertainty in the process of indel formation, (ii) uncertainty in the assumed guide tree and (iii) co-optimal solutions in the pairwise alignments, used as building blocks in progressive alignment algorithms. We compared GUIDANCE2 with seven methodologies to detect unreliable MSA regions using extensive simulations and empirical benchmarks. We show that GUIDANCE2 outperforms all previously developed methodologies. Furthermore, GUIDANCE2 also provides a set of alternative MSAs which can be useful for downstream analyses. The novel algorithm is implemented as a web-server, available at: http://guidance.tau.ac.il. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Progress report

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1979-01-01

    Progress Report, covering the period up to the end of 1979 year, was sent to the IAEA according to the research agreement No. 1971 /CF. This work covered the following fields: preparation and dummy irradiation experiments with a new experimental capsule of ''CHOUCA-M'' type; measurement of temperature fields and design of specimen holders; measurement of neutron energy spectrum in the irradiation place in our experimental reactor of VVR-S type (Nuclear Research Institute) using a set of activation detectors; unification and calibration of the measurement of neutron fluence with the use of Fe, Cu, Mn-Mg and Co-Al monitors; development and improvement of the measuring apparatus and technique for the dynamic testing of pre-cracked specimens with determination of dynamic parameters of fracture mechanics; preparation and manufacture of testing specimens from the Japanese steels - forging, plate and weld metal; preparation of the irradiation capsule for assembling

  7. Correlating tumor metabolic progression index measured by serial FDG PET-CT, apparent diffusion coefficient measured by magnetic resonance imaging (MRI) and blood genomics to patient’s outcome in advanced colorectal cancer: the CORIOLAN study

    International Nuclear Information System (INIS)

    Deleporte, Amelie; Charette, Nicolas; Machiels, Godelieve; Piccart, Martine; Flamen, Patrick; Hendlisz, Alain; Paesmans, Marianne; Garcia, Camilo; Vandeputte, Caroline; Lemort, Marc; Engelholm, Jean-Luc; Hoerner, Frederic; Aftimos, Philippe; Awada, Ahmad

    2014-01-01

    Metastatic colorectal cancer (mCRC) may present various behaviours that define different courses of tumor evolution. There is presently no available tool designed to assess tumor aggressiveness, despite the fact that this is considered to have a major impact on patient outcome. CORIOLAN is a single-arm prospective interventional non-therapeutic study aiming mainly to assess the natural tumor metabolic progression index (TMPI) measured by serial FDG PET-CT without any intercurrent antitumor therapy as a prognostic factor for overall survival (OS) in patients with mCRC. Secondary objectives of the study aim to test the TMPI as a prognostic marker for progression-free survival (PFS), to assess the prognostic value of baseline tumor FDG uptake on PFS and OS, to compare TMPI to classical clinico-biological assessment of prognosis, and to test the prognostic value on OS and PFS of MRI-based apparent diffusion coefficient (ADC) and variation of vADC using voxel-based diffusion maps. Additionally, this study intends to identify genomic and epigenetic factors that correlate with progression of tumors and the OS of patients with mCRC. Consequently, this analysis will provide information about the signaling pathways that determine the natural and therapy-free course of the disease. Finally, it would be of great interest to investigate whether in a population of patients with mCRC, for which at present no known effective therapy is available, tumor aggressiveness is related to elevated levels of circulating tumor cells (CTCs) and to patient outcome. Tumor aggressiveness is one of the major determinants of patient outcome in advanced disease. Despite its importance, supported by findings reported in the literature of extreme outcomes for patients with mCRC treated with chemotherapy, no objective tool allows clinicians to base treatment decisions on this factor. The CORIOLAN study will characterize TMPI using FDG-PET-based metabolic imaging of patients with chemorefractory m

  8. Virtual Ultrasound Guidance for Inexperienced Operators

    Science.gov (United States)

    Caine, Timothy; Martin, David

    2012-01-01

    Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with

  9. Overcoming consumer inertia to dietary guidance.

    Science.gov (United States)

    Webb, Densie; Byrd-Bredbenner, Carol

    2015-07-01

    Despite 35 y of dietary guidance, there has been no substantial shift in consumer compliance. Consumers report that they seek information on nutrition and healthy eating, but most are not paying attention to dietary recommendations. For guidance to be effective, it must be realistic. Even with increasingly detailed nutrition information and evidence that diet affects health outcomes, convenience and taste remain the strongest determinants of food choices. It is up to health educators to clear up confusion and give consumers control with nutrition messages that are realistic, positive, easy to understand, and actionable without an expectation that consumers will surrender foods they love. © 2015 American Society for Nutrition.

  10. Overcoming Consumer Inertia to Dietary Guidance12

    Science.gov (United States)

    Webb, Densie; Byrd-Bredbenner, Carol

    2015-01-01

    Despite 35 y of dietary guidance, there has been no substantial shift in consumer compliance. Consumers report that they seek information on nutrition and healthy eating, but most are not paying attention to dietary recommendations. For guidance to be effective, it must be realistic. Even with increasingly detailed nutrition information and evidence that diet affects health outcomes, convenience and taste remain the strongest determinants of food choices. It is up to health educators to clear up confusion and give consumers control with nutrition messages that are realistic, positive, easy to understand, and actionable without an expectation that consumers will surrender foods they love. PMID:26178023

  11. Narrow dibaryon resonances

    International Nuclear Information System (INIS)

    Kajdalov, A.B.

    1986-01-01

    Experimental data on np interactions indicating to existence of narrow resonances in pp-system are discussed. Possible theoretical interpretations of these resonances are given. Experimental characteristics of the dibaryon resonances with isospin I=2 are considered

  12. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  13. Regenerative feedback resonant circuit

    Science.gov (United States)

    Jones, A. Mark; Kelly, James F.; McCloy, John S.; McMakin, Douglas L.

    2014-09-02

    A regenerative feedback resonant circuit for measuring a transient response in a loop is disclosed. The circuit includes an amplifier for generating a signal in the loop. The circuit further includes a resonator having a resonant cavity and a material located within the cavity. The signal sent into the resonator produces a resonant frequency. A variation of the resonant frequency due to perturbations in electromagnetic properties of the material is measured.

  14. Resonances, resonance functions and spectral deformations

    International Nuclear Information System (INIS)

    Balslev, E.

    1984-01-01

    The present paper is aimed at an analysis of resonances and resonance states from a mathematical point of view. Resonances are characterized as singular points of the analytically continued Lippman-Schwinger equation, as complex eigenvalues of the Hamiltonian with a purely outgoing, exponentially growing eigenfunction, and as poles of the S-matrix. (orig./HSI)

  15. Study Progress of Brain Magnetic Resonance Imaging in Children with Tic Disorders%儿童抽动障碍脑磁共振成像研究进展

    Institute of Scientific and Technical Information of China (English)

    李惠琳; 孙锦华; 杜亚松

    2011-01-01

    At present, many literatures about tic disorders have involved in many aspects including neurobiochemical, neuropsychology and neuroimnge, and so on. Recently, magnetic resonance imaging (MRI) study provides more evidences for tic disorders' etiology. Structural MRI researches detected apparent abnormality in basal ganglia,cortical thinning in frontal and parietal lobes,especially in motorsensory coriix. Functional MRI researches showed that the cortico -striato -thalamo -cortical circuits was dysfunction,and the connection of corpus callosum fiber was reduced. We reviewed the articles about the relationship between brain MRI technique and medicine intervention on tic disorders.%国内外对抽动障碍的研究涉及神经生化、神经心理学、神经影像学等多个领域.近年来磁共振成像研究为抽动障碍病因学研究提供了较多证据.结构磁共振研究发现基底核结构显著异常,额叶、枕叶皮质特别是感觉运动皮质变薄等.而功能磁共振方面则发现皮质-纹状体-丘脑-皮质环路功能异常,胼胝体纤维连接程度下降等.现就抽动障碍与磁共振成像、药物干预之间的关系进行综述.

  16. 28 CFR 91.53 - Other guidance.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Other guidance. 91.53 Section 91.53 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) GRANTS FOR CORRECTIONAL FACILITIES Environmental... Justice has also published NEPA procedures that incorporate the CEQ regulations at 28 CFR part 61...

  17. 21 CFR 601.29 - Guidance documents.

    Science.gov (United States)

    2010-04-01

    ... Manufacturers Assistance (HFM-40), Center for Biologics Evaluation and Research, Food and Drug Administration... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Guidance documents. 601.29 Section 601.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS...

  18. 21 CFR 312.145 - Guidance documents.

    Science.gov (United States)

    2010-04-01

    ... of Drug Information, Center for Drug Evaluation and Research, Food and Drug Administration, 10903 New... Evaluation and Research, Food and Drug Administration, 1401 Rockville Pike, Rockville, MD 20852-1448. [65 FR... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Guidance documents. 312.145 Section 312.145 Food...

  19. Chinese Human Rights Guidance on Minerals Sourcing

    DEFF Research Database (Denmark)

    Buhmann, Karin

    2017-01-01

    in the minerals sector and due diligence to ensure socially responsible sourcing of minerals with a particular focus on human rights, the guidelines refer to international human rights standards and are designed to be consistent with guidance issued by the OECD. The article discusses the Chinese guidelines...

  20. Guidance for performing site inspections under CERCLA

    Energy Technology Data Exchange (ETDEWEB)

    1992-09-01

    This guidance presents EPA`s site inspection (SI) strategy. The strategy discusses procedural guidelines to investigate potential Superfund (CERCLA) sites for evaluation pursuant to the Hazard Ranking System (HRS), revised in accordance with the Superfund Amendments and Reauthorization Act of 1986. The HRS is the primary means by which EPA evaluates sites for superfund`s National Priorities List (NPL).

  1. Bridge over troubled water: Guidance crosses | Amundson ...

    African Journals Online (AJOL)

    This article is based on a keynote presentation at an international conference where the focus was cross-over career guidance. Simon and Garfunkel's popular song, "Bridge ... and the future, and building connections. There also was the suggestion that other metaphors could be used as a way to broaden the exploration.

  2. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  3. The Guidance Counselor and the Reading Curriculum.

    Science.gov (United States)

    Ediger, Marlow

    There are many ways guidance counselors can help teachers achieve more optimal reading instruction. Counselors first may have to ascertain the kinds of problems faced by a student in learning to read. Assessing a student's ability to use picture clues to decipher words may be necessary with primary grade students. Knowledge about phonics, using…

  4. Guidance of eruption for general practitioners.

    Science.gov (United States)

    Ngan, Peter W; Kao, Elizabeth C; Wei, Stephen H

    2003-04-01

    The principle of early treatment through well-planned extraction of primary teeth followed by removal of permanent teeth has stood the test of time. The objective of this article is to develop some simple guidelines for general dental practitioners to perform 'guidance of eruption' in malocclusion with severe crowding.

  5. ROUTE PLAN DESIGNER FOR TRACTOR GUIDANCE SYSTEMS

    DEFF Research Database (Denmark)

    Sveistrup, Daniel; Jørgensen, Rasmus Nyholm; Green, Ole

    2010-01-01

    Earlier works have shown field trial designs to be very labor extensive, even when combining autoguidancesystems with conventional machinery.Designing routes for semi-automated systems in a controlled manner is both resource demandingand complicated. Different types of auto-guidance systems vary ...

  6. RMP Guidance for Chemical Distributors - Appendix D: OSHA Guidance on PSM

    Science.gov (United States)

    Guidance on the Process Safety Management standard says information (including MSDS) about chemicals, including process intermediates, must enable accurate assessment of fire/explosion characteristics, reactivity hazards, and corrosing/erosion effects.

  7. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  8. A Formal Investigation of the Organization of Guidance Behavior: Implications for Humans and Autonomous Guidance

    Science.gov (United States)

    Kong, Zhaodan

    Guidance behavior generated either by artificial agents or humans has been actively studied in the fields of both robotics and cognitive science. The goals of these two fields are different. The former is the automatic generation of appropriate or even optimal behavior, while the latter is the understanding of the underlying mechanism. Their challenges, though, are closely related, the most important one being the lack of a unified, formal and grounded framework where the guidance behavior can be modeled and studied. This dissertation presents such a framework. In this framework, guidance behavior is analyzed as the closed-loop dynamics of the whole agent-environment system. The resulting dynamics give rise to interaction patterns. The central points of this dissertation are that: first of all, these patterns, which can be explained in terms of symmetries that are inherent to the guidance behavior, provide building blocks for the organization of behavior; second, the existence of these patterns and humans' organization of their guidance behavior based on these patterns are the reasons that humans can generate successful behavior in spite of all the complexities involved in the planning and control. This dissertation first gives an overview of the challenges existing in both scientific endeavors, such as human and animal spatial behavior study, and engineering endeavors, such as autonomous guidance system design. It then lays out the foundation for our formal framework, which states that guidance behavior should be interpreted as the collection of the closed-loop dynamics resulting from the agent's interaction with the environment. The following, illustrated by examples of three different UAVs, shows that the study of the closed-loop dynamics should not be done without the consideration of vehicle dynamics, as is the common practice in some of the studies in both autonomous guidance and human behavior analysis. The framework, the core concepts of which are

  9. Intraluminal ultrasound guidance of transverse laser coronary atherectomy

    Science.gov (United States)

    Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Sedlacek, Tomas; Hatch, G. F.; Gregg, Richard E.

    1990-07-01

    A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.

  10. Theoretical nuclear structure and astrophysics. Progress report for 1996

    International Nuclear Information System (INIS)

    Guidry, M.W.; Nazarewicz, W.; Strayer, M.R.

    1996-01-01

    This research effort is directed toward theoretical support and guidance for the fields of radioactive ion beam physics, gamma ray spectroscopy, computational and nuclear astrophysics, and the interface between these disciplines. The authors report substantial progress in all those areas. One measure of progress is publications and invited material. The research described here has led to more than 43 papers that are published, accepted, or submitted to refereed journals, and to 15 invited presentations at conferences and workshops

  11. A double-blind, randomized controlled trial to compare the effect of biannual peripheral magnetic resonance imaging, radiography and standard of care disease progression monitoring on pharmacotherapeutic escalation in rheumatoid and undifferentiated inflammatory arthritis: study protocol for a randomized controlled trial

    Science.gov (United States)

    2014-01-01

    Background Permanent joint damage is a major consequence of rheumatoid arthritis (RA), the most common and destructive form of inflammatory arthritis. In aggressive disease, joint damage can occur within 6 months from symptom onset. Early, intensive treatment with conventional and biologic disease-modifying anti-rheumatic drugs (DMARDs) can delay the onset and progression of joint damage. The primary objective of the study is to investigate the value of magnetic resonance imaging (MRI) or radiography (X-ray) over standard of care as tools to guide DMARD treatment decision-making by rheumatologists for the care of RA. Methods A double-blind, randomized controlled trial has been designed. Rheumatoid and undifferentiated inflammatory arthritis patients will undergo an MRI and X-ray assessment every 6 months. Baseline adaptive randomization will be used to allocate participants to MRI, X-ray, or sham-intervention groups on a background of standard of care. Prognostic markers, treating physician, and baseline DMARD therapy will be used as intervention allocation parameters. The outcome measures in rheumatology RA MRI score and the van der Heijde-modified Sharp score will be used to evaluate the MRI and X-ray images, respectively. Radiologists will score anonymized images for all patients regardless of intervention allocation. Disease progression will be determined based on the study-specific, inter-rater smallest detectable difference. Allocation-dependent, intervention-concealed reports of positive or negative disease progression will be reported to the treating rheumatologist. Negative reports will be delivered for the sham-intervention group. Study-based radiology clinical reports will be provided to the treating rheumatologists for extra-study X-ray requisitions to limit patient radiation exposure as part of diagnostic imaging standard of care. DMARD treatment dose escalation and therapy changes will be measured to evaluate the primary objective. A sample size of

  12. FY2015 Lightweight Materials R&D Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-09-30

    The Lightweight Materials research and development (R&D) area within the DOE Vehicle Technologies Office (VTO) provides support and guidance for many cutting-edge automotive technologies under development. Research focuses on addressing critical barriers to commercializing lightweight materials for passenger and commercial vehicles. This report describes the progress made on the research and development projects funded by the Lightweight Materials area.

  13. Intralabyrinthine schwannoma shown by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saeed, S.R.; Birzgalis, A.R.; Ramsden, R.T.

    1994-01-01

    Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Menieres disease. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery. (orig.)

  14. Design Guidance for New Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  15. Design Guidance for Replacement Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  16. 78 FR 25454 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2013-05-01

    ... NIOSH-161-A] Issuance of Final Guidance Publication AGENCY: National Institute for Occupational Safety... Human Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The National...), announces the availability of the following publication: ``NIOSH Current Intelligence Bulletin 65...

  17. 77 FR 74194 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2012-12-13

    ... NIOSH-238] Issuance of Final Guidance Publication AGENCY: National Institute for Occupational Safety and... Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The National Institute...), announces the availability of the following publication: NIOSH Alert entitled ``Preventing Occupational...

  18. 78 FR 13097 - Electric Power Research Institute; Seismic Evaluation Guidance

    Science.gov (United States)

    2013-02-26

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0038] Electric Power Research Institute; Seismic... Electric Power Research Institute (EPRI)-1025287, ``Seismic Evaluation Guidance: Screening, Prioritization... guidance and clarification of an acceptable approach to assist nuclear power reactor licensees when...

  19. Strategies for Structural Youth Unemployment: a Capability Approach for Guidance

    OpenAIRE

    Massimiliano Costa; Daniele Morselli; John Polesel; Suzanne Rice

    2015-01-01

    The aim of this article is to present an innovative approach for guidance. The article starts by introducing the structural reason of unemployment in Italy. It presents the Australian model of guidance and the new reforms on guidance which are being introduced in Italy. It then describes a Change Laboratory intervention carried in a vocational setting in Australia in 2012, which is proposed as model of guidance based on the capability approach.The different stakeholders actively participate i...

  20. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  1. Taxonometric Guidance for Developing Quality Assurance

    International Nuclear Information System (INIS)

    Thomadsen, Bruce; Lin, She-Woei

    2008-01-01

    A taxonomy is an ordered classification system. In error reduction analysis, an examination of the human failures that lead to an event often uses a taxonomy to classify the failures according to some aspect of their characteristics. These classifications provide insights into the forces that kept the persons involved from achieving their intended actions. They also can provide guidance for changing the situation to prevent failure in the future. For example, the corrective action would be different if a therapist pressed the wrong button because several buttons looked alike or they forgot which button to press. Different types of failures lead to particular types of remediation. Taxonomies can provide guidance in selecting between possible corrective actions

  2. Guidance and justification in particularistic ethics.

    Science.gov (United States)

    Kihlbom, U

    2000-10-01

    This paper argues that, contrary to a common line of criticism followed by scholars such as Helga Kuhse, a particularistic version of virtue ethics properly elaborated, can provide sound moral guidance and a satisfactory account for moral justification of our opinions regarding, for instance, health care practice. In the first part of the paper, three criteria for comparing normative theories with respect to action-guiding power are outlined, and it is argued that the presented particularistic version of virtue ethics actually can provide more guidance than the universalistic theories followed by Kuhse and others. In the second part of the paper it is claimed that universalist normative theories have serious problems accounting for the role that moral principles are supposed to play in the justification, of moral opinions, whereas the present version of virtue ethics accommodates a plausible alternative idea of justification without invoking moral principles or eschewing objectivity.

  3. Meninges-derived cues control axon guidance.

    Science.gov (United States)

    Suter, Tracey A C S; DeLoughery, Zachary J; Jaworski, Alexander

    2017-10-01

    The axons of developing neurons travel long distances along stereotyped pathways under the direction of extracellular cues sensed by the axonal growth cone. Guidance cues are either secreted proteins that diffuse freely or bind the extracellular matrix, or membrane-anchored proteins. Different populations of axons express distinct sets of receptors for guidance cues, which results in differential responses to specific ligands. The full repertoire of axon guidance cues and receptors and the identity of the tissues producing these cues remain to be elucidated. The meninges are connective tissue layers enveloping the vertebrate brain and spinal cord that serve to protect the central nervous system (CNS). The meninges also instruct nervous system development by regulating the generation and migration of neural progenitors, but it has not been determined whether they help guide axons to their targets. Here, we investigate a possible role for the meninges in neuronal wiring. Using mouse neural tissue explants, we show that developing spinal cord meninges produce secreted attractive and repulsive cues that can guide multiple types of axons in vitro. We find that motor and sensory neurons, which project axons across the CNS-peripheral nervous system (PNS) boundary, are attracted by meninges. Conversely, axons of both ipsi- and contralaterally projecting dorsal spinal cord interneurons are repelled by meninges. The responses of these axonal populations to the meninges are consistent with their trajectories relative to meninges in vivo, suggesting that meningeal guidance factors contribute to nervous system wiring and control which axons are able to traverse the CNS-PNS boundary. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Development of raphe serotonin neurons from specification to guidance.

    Science.gov (United States)

    Kiyasova, Vera; Gaspar, Patricia

    2011-11-01

    The main features of the development of the serotonin (5-HT) raphe neurons have been known for many years but more recent molecular studies, using mouse genetics, have since unveiled several intriguing aspects of the specification of the raphe serotonergic system. These studies indicated that, although all 5-HT neurons in the raphe follow the same general program for their specification, there are also clear regional differences in the way that these neurons are specified and are guided towards different brain targets. Here we overview recent progress made in the understanding of the developmental programming of serotonergic neurons in the mouse raphe, emphasizing data showing how heterogeneous subsets of 5-HT neurons may be generated. Serotonergic progenitors are produced in the brainstem in different rhombomeres under the influence of a set of secreted factors, sonic hedgehog and fibroblast growth factors, which determine their position in the neural tube. Two main transcriptional gene networks are involved in the specification of 5-HT identity, with Lmx1b and Pet1 transcription factors as main players. A differential requirement for Pet1 was, however, revealed, which underlies an anatomical and functional diversity. Transcriptional programs controlling 5-HT identity could also impact axon guidance mechanisms directing 5-HT neurons to their targets. Although no direct links have yet been established, a large set of molecular determinants have already been shown to be involved in the growth, axon guidance and targeting of 5-HT raphe neurons, particularly within the forebrain. Alterations in the molecular mechanisms involved in 5-HT development are likely to have significant roles in mood disease predisposition. © 2011 The Authors. European Journal of Neuroscience © 2011 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  5. River City High School Guidance Services: A Conceptual Model.

    Science.gov (United States)

    American Coll. Testing Program, Iowa City, IA.

    This model describes how the guidance staff at a hypothetical high school communicated the effectiveness of the guidance program to students, parents, teachers, and administrators. A description of the high school is presented, and guidance services and personnel are described. A conceptual model responding to student needs is outlined along with…

  6. 76 FR 411 - Regulatory Guidance Concerning Electronic Signatures and Documents

    Science.gov (United States)

    2011-01-04

    ... guidance, including memoranda and letters, may no longer be relied upon to the extent they are inconsistent... Concerning Electronic Signatures and Documents AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of regulatory guidance. SUMMARY: FMCSA issues regulatory guidance concerning the...

  7. Adapting haptic guidance authority based on user grip

    NARCIS (Netherlands)

    Smisek, J.; Mugge, W.; Smeets, J.B.J.; Van Paassen, M.M.; Schiele, A

    2014-01-01

    Haptic guidance systems support the operator in task execution using additional forces on the input device. Scaling of the guidance forces determines the control authority of the support system. As task complexity may vary, one level of the guidance scaling may be insufficient, and adaptation of the

  8. Assessment of Adaptive Guidance for Responsive Launch Vehicles and Spacecraft

    Science.gov (United States)

    2009-04-29

    Figures 1 Earth centered inertial and launch plumbline coordinate systems . . . . . . . 7 2 Geodetic and geocentric latitude...Dramatically reduced reoccurring costs related to guidance. The same features of the closed-loop ascent guidance that provide operational flexibility...also result in greatly reduced need for human intervention. Thus the operational costs related to ascent guidance could be reduced to minimum

  9. 78 FR 49782 - Interim Staff Guidance on Changes During Construction

    Science.gov (United States)

    2013-08-15

    ... Construction AGENCY: Nuclear Regulatory Commission. ACTION: Draft interim staff guidance; request for comment... During Construction.'' This ISG provides guidance to the NRC staff on the Preliminary Amendment Request...-ISG-025 ``Interim Staff Guidance on Changes during Construction under 10 CFR Part 52'' is available...

  10. Observability-Based Guidance and Sensor Placement

    Science.gov (United States)

    Hinson, Brian T.

    Control system performance is highly dependent on the quality of sensor information available. In a growing number of applications, however, the control task must be accomplished with limited sensing capabilities. This thesis addresses these types of problems from a control-theoretic point-of-view, leveraging system nonlinearities to improve sensing performance. Using measures of observability as an information quality metric, guidance trajectories and sensor distributions are designed to improve the quality of sensor information. An observability-based sensor placement algorithm is developed to compute optimal sensor configurations for a general nonlinear system. The algorithm utilizes a simulation of the nonlinear system as the source of input data, and convex optimization provides a scalable solution method. The sensor placement algorithm is applied to a study of gyroscopic sensing in insect wings. The sensor placement algorithm reveals information-rich areas on flexible insect wings, and a comparison to biological data suggests that insect wings are capable of acting as gyroscopic sensors. An observability-based guidance framework is developed for robotic navigation with limited inertial sensing. Guidance trajectories and algorithms are developed for range-only and bearing-only navigation that improve navigation accuracy. Simulations and experiments with an underwater vehicle demonstrate that the observability measure allows tuning of the navigation uncertainty.

  11. Guidance and control, 1993; Annual Rocky Mountain Guidance and Control Conference, 16th, Keystone, CO, Feb. 6-10, 1993

    Science.gov (United States)

    Culp, Robert D.; Bickley, George

    Papers from the sixteenth annual American Astronautical Society Rocky Mountain Guidance and Control Conference are presented. The topics covered include the following: advances in guidance, navigation, and control; control system videos; guidance, navigation and control embedded flight control systems; recent experiences; guidance and control storyboard displays; and applications of modern control, featuring the Hubble Space Telescope (HST) performance enhancement study. For individual titles, see A95-80390 through A95-80436.

  12. Progress in neuromorphic photonics

    Science.gov (United States)

    Ferreira de Lima, Thomas; Shastri, Bhavin J.; Tait, Alexander N.; Nahmias, Mitchell A.; Prucnal, Paul R.

    2017-03-01

    As society's appetite for information continues to grow, so does our need to process this information with increasing speed and versatility. Many believe that the one-size-fits-all solution of digital electronics is becoming a limiting factor in certain areas such as data links, cognitive radio, and ultrafast control. Analog photonic devices have found relatively simple signal processing niches where electronics can no longer provide sufficient speed and reconfigurability. Recently, the landscape for commercially manufacturable photonic chips has been changing rapidly and now promises to achieve economies of scale previously enjoyed solely by microelectronics. By bridging the mathematical prowess of artificial neural networks to the underlying physics of optoelectronic devices, neuromorphic photonics could breach new domains of information processing demanding significant complexity, low cost, and unmatched speed. In this article, we review the progress in neuromorphic photonics, focusing on photonic integrated devices. The challenges and design rules for optoelectronic instantiation of artificial neurons are presented. The proposed photonic architecture revolves around the processing network node composed of two parts: a nonlinear element and a network interface. We then survey excitable lasers in the recent literature as candidates for the nonlinear node and microring-resonator weight banks as the network interface. Finally, we compare metrics between neuromorphic electronics and neuromorphic photonics and discuss potential applications.

  13. 78 FR 12761 - Guidance for Industry: Guidance on the Labeling of Certain Uses of Lecithin Derived From Soy...

    Science.gov (United States)

    2013-02-25

    ...] (formerly 2006D-0169) Guidance for Industry: Guidance on the Labeling of Certain Uses of Lecithin Derived... on the Labeling of Certain Uses of Lecithin Derived From Soy Under Section 403(w) of the Federal Food.... The guidance explained FDA's then current thinking on the labeling of certain uses of lecithin derived...

  14. 77 FR 34390 - Draft Guidance for Industry: Amendment to “Guidance for Industry: Revised Preventive Measures To...

    Science.gov (United States)

    2012-06-11

    ... recommendations for plasma-derived products, including albumin and products containing plasma-derived albumin, in..., submit either electronic or written comments on the draft guidance by September 10, 2012. ADDRESSES... electronic access to the draft guidance document. Submit electronic comments on the draft guidance to http...

  15. 78 FR 12759 - Draft Guidance for Industry on Attachment to Guidance on Antiviral Product Development-Conducting...

    Science.gov (United States)

    2013-02-25

    ...; formerly 2005D-0183] Draft Guidance for Industry on Attachment to Guidance on Antiviral Product Development... guidance to the Division of Drug Information, Center for Drug Evaluation and Research, Food and Drug... 20852. FOR FURTHER INFORMATION CONTACT: Lisa K. Naeger, Center for Drug Evaluation and Research, Food...

  16. European Lifelong Guidance Policy Network Representatives' Conceptions of the Role of Information and Communication Technologies Related to National Guidance Policies

    Science.gov (United States)

    Kettunen, Jaana; Vuorinen, Raimo; Ruusuvirta, Outi

    2016-01-01

    This article reports findings from a phenomenographic investigation into European Lifelong Guidance Policy Network representatives' conceptions of the role of information and communication technologies (ICT) related to national lifelong guidance policies. The role of ICT in relation to national lifelong guidance policies was conceived as (1)…

  17. 75 FR 54637 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2010-09-08

    ... conferencing and electronic submissions, Mammography Matters, and other device-oriented information. The CDRH... approval) into class II (special controls). DATES: Submit written or electronic comments on this guidance... electronic access to the guidance. Submit electronic comments on the guidance to http://www.regulations.gov...

  18. Contextual cueing improves attentional guidance, even when guidance is supposedly optimal.

    Science.gov (United States)

    Harris, Anthony M; Remington, Roger W

    2017-05-01

    Visual search through previously encountered contexts typically produces reduced reaction times compared with search through novel contexts. This contextual cueing benefit is well established, but there is debate regarding its underlying mechanisms. Eye-tracking studies have consistently shown reduced number of fixations with repetition, supporting improvements in attentional guidance as the source of contextual cueing. However, contextual cueing benefits have been shown in conditions in which attentional guidance should already be optimal-namely, when attention is captured to the target location by an abrupt onset, or under pop-out conditions. These results have been used to argue for a response-related account of contextual cueing. Here, we combine eye tracking with response time to examine the mechanisms behind contextual cueing in spatially cued and pop-out conditions. Three experiments find consistent response time benefits with repetition, which appear to be driven almost entirely by a reduction in number of fixations, supporting improved attentional guidance as the mechanism behind contextual cueing. No differences were observed in the time between fixating the target and responding-our proxy for response related processes. Furthermore, the correlation between contextual cueing magnitude and the reduction in number of fixations on repeated contexts approaches 1. These results argue strongly that attentional guidance is facilitated by familiar search contexts, even when guidance is near-optimal. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Resonance ionization spectroscopy 1990

    International Nuclear Information System (INIS)

    Parks, J.E.; Omenetto, N.

    1991-01-01

    The Fifth International Symposium on Resonance Ionization Spectroscopy (RIS) and its Applications was held in Varese, Italy, 16-21 September 1990. Interest in RIS and its applications continues to grow, and RIS is expanding into a more diverse and mature field of study. This maturity was evident in this meeting both in the basic science and understanding of RIS processes and in the number of new and improved applications and techniques. The application of RIS techniques to molecular detection problems made remarkable progress since the last meeting two years ago. Subtle effects pertaining to isotopic discrimination received more theoretical attention, and there now seems to be good understanding of these effects, which can lead to correction procedures and/or methods to avoid isotopic effects. RIS applications were presented in which significant, real world problems were addressed, demonstrating its capability to solve problems that previously could not be accurately solved by other more traditional techniques. The contributions to the conference are grouped under the following major topic headings: physics applications of rare atoms; laser ionization mechanisms - spectroscopy; atomic, molecular and ion sources; molecular RIS; atomic RIS - Rydberg states; environmental trace analysis; biological and medical applications; state selected chemistry; new laser sources and techniques; ultra-high resolution and isotopic selectivity; surface and bulk analysis. (Author)

  20. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  1. On the design of fuzzified trajectory shaping guidance law.

    Science.gov (United States)

    Lin, Chun-Liang; Lin, Yu-Ping; Chen, Kai-Ming

    2009-04-01

    Midcourse guidance is commonly designed to save as much energy as possible so that the missile's final speed can be maximized while entering the homing stage. For this purpose, a competitive guidance design should be able to generate an admissible flight trajectory as to bring the interceptor to a superior altitude for a favorable target engagement. In this paper, a new adaptive trajectory shaping guidance scheme based on the adaptive fuzzy inference system, which is capable of generating a variety of trajectories for efficient target interception, is presented. The guidance law is developed with the aim of saving the interceptor's energy conservation while improving performance robustness. Applications of the presented approach have included a variety of mission oriented guidance, such as cruise missile guidance, anti-ballistic missile guidance, etc.

  2. Status of neutron cross sections of transactinium isotopes in the resonance region - linear accelerator measurements

    International Nuclear Information System (INIS)

    James, G.D.

    1976-01-01

    A review of the status of transactinium isotope cross sections in the resonance region and of resolved resonance parameters is given by summarising the work submitted by fourteen contributors and also by highlighting other work where notable progress has been made in our knowledge of neutron resonance phenomena. (author)

  3. Percutaneous Cryoablation of Small Hepatocellular Carcinoma with US Guidance and CT Monitoring: Initial Experience

    International Nuclear Information System (INIS)

    Orlacchio, Antonio; Bazzocchi, Gabriele; Pastorelli, Daniela; Bolacchi, Francesca; Angelico, Mario; Almerighi, Cristiana; Masala, Salvatore; Simonetti, Giovanni

    2008-01-01

    The purpose of this study was to retrospectively determine the safety and effectiveness of percutaneous cryoablation, monitored with computed tomography (CT) and ultrasonographic (US) guidance, for the treatment of hepatocellular carcinoma (HCC). Four patients with small HCCs underwent one percutaneous cryoablation treatment session monitored with CT and US guidance. All patients underwent pretreatment blood chemistry testing and imaging evaluation. We treated lesions with simultaneous insertion of multiple 17-G cryoprobes (two or three) and defined technical success when the extension of a visible iceball was beyond 5 mm from the tumor margin. Intralesional enhancement or tumoral size increase was defined as local progression compared with that on images obtained immediately after ablation. We evaluated complications and follow-up (at 1, 3, and 6 months). All patients survived without short- or long-term complications. Cryoablation was technically successful in all patients at the end of the procedure. During follow-up two patients developed disease recurrence. One patient developed local tumor progression on the margin of the lesion; the other, a new HCC. In the case of local tumor progression a new elevation of α-fetoprotein (αFP) levels occurred at first follow-up control. In the other case levels of αFP remained stable during the first 3 months after the procedure, then demonstrated a progressive increase in αFP levels beginning at the fourth month, without tumor evidence during CT control at 3 months. We conclude that percutaneous cryotherapy with US guidance and CT monitoring is a feasible, safe, and effective for treatment of HCC. If local ablative procedures of hepatic lesions are to be performed, percutaneous cryoablation, not laparotomic, should be discussed as an alternative therapeutic measure. Longer follow-up should provide proof of the effectiveness of this technique

  4. Crossing simple resonances

    International Nuclear Information System (INIS)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances

  5. Acoustic Fano resonators

    KAUST Repository

    Amin, Muhammad; Farhat, Mohamed; Bagci, Hakan

    2014-01-01

    The resonances with asymmetric Fano line-shapes were originally discovered in the context of quantum mechanics (U. Fano, Phys. Rev., 124, 1866-1878, 1961). Quantum Fano resonances were generated from destructive interference of a discrete state

  6. Neutron resonance averaging

    International Nuclear Information System (INIS)

    Chrien, R.E.

    1986-10-01

    The principles of resonance averaging as applied to neutron capture reactions are described. Several illustrations of resonance averaging to problems of nuclear structure and the distribution of radiative strength in nuclei are provided. 30 refs., 12 figs

  7. Crossing simple resonances

    Energy Technology Data Exchange (ETDEWEB)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances.

  8. Isotopic Resonance Hypothesis: Experimental Verification by Escherichia coli Growth Measurements

    Science.gov (United States)

    Xie, Xueshu; Zubarev, Roman A.

    2015-03-01

    Isotopic composition of reactants affects the rates of chemical and biochemical reactions. As a rule, enrichment of heavy stable isotopes leads to progressively slower reactions. But the recent isotopic resonance hypothesis suggests that the dependence of the reaction rate upon the enrichment degree is not monotonous. Instead, at some ``resonance'' isotopic compositions, the kinetics increases, while at ``off-resonance'' compositions the same reactions progress slower. To test the predictions of this hypothesis for the elements C, H, N and O, we designed a precise (standard error +/-0.05%) experiment that measures the parameters of bacterial growth in minimal media with varying isotopic composition. A number of predicted resonance conditions were tested, with significant enhancements in kinetics discovered at these conditions. The combined statistics extremely strongly supports the validity of the isotopic resonance phenomenon (p biotechnology, medicine, chemistry and other areas.

  9. Human Guidance Behavior Decomposition and Modeling

    Science.gov (United States)

    Feit, Andrew James

    Trained humans are capable of high performance, adaptable, and robust first-person dynamic motion guidance behavior. This behavior is exhibited in a wide variety of activities such as driving, piloting aircraft, skiing, biking, and many others. Human performance in such activities far exceeds the current capability of autonomous systems in terms of adaptability to new tasks, real-time motion planning, robustness, and trading safety for performance. The present work investigates the structure of human dynamic motion guidance that enables these performance qualities. This work uses a first-person experimental framework that presents a driving task to the subject, measuring control inputs, vehicle motion, and operator visual gaze movement. The resulting data is decomposed into subspace segment clusters that form primitive elements of action-perception interactive behavior. Subspace clusters are defined by both agent-environment system dynamic constraints and operator control strategies. A key contribution of this work is to define transitions between subspace cluster segments, or subgoals, as points where the set of active constraints, either system or operator defined, changes. This definition provides necessary conditions to determine transition points for a given task-environment scenario that allow a solution trajectory to be planned from known behavior elements. In addition, human gaze behavior during this task contains predictive behavior elements, indicating that the identified control modes are internally modeled. Based on these ideas, a generative, autonomous guidance framework is introduced that efficiently generates optimal dynamic motion behavior in new tasks. The new subgoal planning algorithm is shown to generate solutions to certain tasks more quickly than existing approaches currently used in robotics.

  10. Early school leaving and lifelong guidance

    DEFF Research Database (Denmark)

    Plant, Peter; Oomen, Annemarie

    Early school leaving (ESL) is costly for the individual, for society and for the economy. Not just in economic terms, but also in terms of low self esteem, and the risk of social exclusion. More, and, in particular, better education can lead to positive outcomes, in relation to employment, level...... of salaries, better health, less crime, higher social cohesion, lower public and social costs and higher productivity. This is why ESL is a policy focal point. In these terms, lifelong guidance has a key role to play in terms of both prevention, intervention, and of compensation strategies....

  11. Cannabinoid receptor CB2 modulates axon guidance

    DEFF Research Database (Denmark)

    Duff, Gabriel; Argaw, Anteneh; Cecyre, Bruno

    2013-01-01

    on axon guidance. These effects are specific to CB2R since no changes were observed in mice where the gene coding for this receptor was altered (cnr2 (-/-)). The CB2R induced morphological changes observed at the growth cone are PKA dependent and require the presence of the netrin-1 receptor, Deleted...... CB2R's implication in retinothalamic development. Overall, this study demonstrates that the contribution of endocannabinoids to brain development is not solely mediated by CB1R, but also involves CB2R....

  12. Avoiding plagiarism: guidance for nursing students.

    Science.gov (United States)

    Price, Bob

    The pressures of study, diversity of source materials, past assumptions relating to good writing practice, ambiguous writing guidance on best practice and students' insecurity about their reasoning ability, can lead to plagiarism. With the use of source checking software, there is an increased chance that plagiarised work will be identified and investigated, and penalties given. In extreme cases, plagiarised work may be reported to the Nursing and Midwifery Council and professional as well as academic penalties may apply. This article provides information on how students can avoid plagiarism when preparing their coursework for submission.

  13. Equal employment opportunity plan development guidance

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-09-01

    The purpose of this publication is to provide instructions for the development of EEO Plans for Fiscal Year 1979. It supplements the National EEO Plan for the Department of Energy issued in August 1978 (DOE/S-0002). The material included should be used immediately as guidance to develop, document, and implement subordinate echelon commitments to EEO. A schedule for the development and submission of EEO Plans is included. Most of the continuing requirements will be published at a later date as part of the directives system. Any comments or helpful suggestions concerned with the program outlined would be appreciated by the Office of Equal Opportunity.

  14. Configuration management: Phase II implementation guidance

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    Configuration management (CM) is essential to maintaining an acceptable level of risk to the public, workers, environment, or mission success. It is a set of activities and techniques used to maintain consistency among physical and functional configuration, applicable requirements, and key documents. This document provides guidance for continuing the implementation of CM in a phased and graded manner. It describes a cost-effective approach to documented consistency with requirements, with early emphasis on items most important to safety and environmental protection. It is intended to help responsible line managers and configuration management staff personnel in meeting the Energy Systems configuration management policy standard.

  15. Environmental restoration value engineering guidance document

    International Nuclear Information System (INIS)

    1995-07-01

    This document provides guidance on Value Engineering (VE). VE is an organized team effort led by a person trained in the methodology to analyze the functions of projects, systems, equipment, facilities, services, and processes for achieving the essential functions at the lowest life cycle cost while maintaining required performance, reliability, availability, quality, and safety. VE has proven to be a superior tool to improve up-front project planning, cut costs, and create a better value for each dollar spent. This document forms the basis for the Environmental Restoration VE Program, describes the VE process, and provides recommendations on when it can be most useful on ER projects

  16. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  17. Resonant thermonuclear reaction rate

    International Nuclear Information System (INIS)

    Haubold, H.J.; Mathai, A.M.

    1986-01-01

    Basic physical principles for the resonant and nonresonant thermonuclear reaction rates are applied to find their standard representations for nuclear astrophysics. Closed-form representations for the resonant reaction rate are derived in terms of Meijer's G-function. Analytic representations of the resonant and nonresonant nuclear reaction rates are compared and the appearance of Meijer's G-function is discussed in physical terms

  18. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  19. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  20. Resection of deep-seated gliomas using neuroimaging for stereotactic placement of guidance catheters

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kengo; Higashi, Hisato; Tomita, Susumu; Furuta, Tomohisa; Ohmoto, Takashi [Okayama Univ. (Japan). School of Medicine

    1995-03-01

    A simple computed tomography- (CT) or magnetic resonance (MR) imaging-guided stereotactic method for guided microsurgical resection of either deep-seated gliomas or tumors adjacent to an eloquent area is described. The technique employs the Brown-Roberts-Wells stereotactic system and twist drills, 2.7 mm in diameter, for the stereotactic placement of 2.4 mm diameter scaled guidance catheters through the calvaria. In a patient with a deep-seated small glioma, less than 2 cm diameter, one catheter was implanted into the center of the enhanced mass through the cerebral cortex. In the other 14 patients, three to six catheters were used which made the tumor border clearer. After implantation of the guidance catheters, the stereotactic frame was removed and a standard open craniotomy performed. Target localization is not affected by brain movement, which is inevitable during open surgery. The tumor involved the frontal lobe in eight patients, the parietal lobe in two, and the thalamus in five. In all cases the lesion was quickly localized and radical removal was acheived. Neurological complications occurred in only one patient who suffered transient hemiparesis after the resection of a lesion in the pyramidal tract. The results demonstrate that microsurgery combined with CT- or MR imaging-guided stereotactic placement of guidance catheters is a new option for surgery of deep-seated gliomas or tumors adjacent to an eloquent area. (author).

  1. 78 FR 67442 - Congestion Mitigation and Air Quality Improvement Program Interim Guidance

    Science.gov (United States)

    2013-11-12

    ...] Congestion Mitigation and Air Quality Improvement Program Interim Guidance AGENCY: Federal Highway... Comment. SUMMARY: The FHWA is issuing Interim Guidance on the Congestion Mitigation and Air Quality.../environment/air_quality/cmaq/policy_and_guidance/2008_guidance/ guidance/. DATES: This Interim Guidance is...

  2. Green positive guidance and green positive life counseling for decent work and decent lives:Some empirical results

    Directory of Open Access Journals (Sweden)

    Annamaria eDi Fabio

    2016-03-01

    Full Text Available This article discusses green positive guidance and green positive life counseling for decent work and decent lives. From a green guidance perspective, the connectedness to nature construct is important both in terms of the meaning of work and life construction. The study discussed in this article analyzed the relationship between empathy and connectedness to nature, controlling for the effects of fluid intelligence and personality traits. In this connection, the Advanced Progressive Matrices (APM, the Big Five Questionnaire (BFQ, and the Interpersonal Reactivity Index (IRI were administered to 144 Italian high school students. The study revealed that connecteness to nature was not associated with fluid intelligence and was only moderately associated with personality traits. It was empathy that showed the highest association with connectedness to nature. The results open new opportunities for future research and interventions in green positive guidance/life counseling and green positive decent work.

  3. Video-Guidance Design for the DART Rendezvous Mission

    Science.gov (United States)

    Ruth, Michael; Tracy, Chisholm

    2004-01-01

    NASA's Demonstration of Autonomous Rendezvous Technology (DART) mission will validate a number of different guidance technologies, including state-differenced GPS transfers and close-approach video guidance. The video guidance for DART will employ NASA/Marshall s Advanced Video Guidance Sensor (AVGS). This paper focuses on the terminal phase of the DART mission that includes close-approach maneuvers under AVGS guidance. The closed-loop video guidance design for DART is driven by a number of competing requirements, including a need for maximizing tracking bandwidths while coping with measurement noise and the need to minimize RCS firings. A range of different strategies for attitude control and docking guidance have been considered for the DART mission, and design decisions are driven by a goal of minimizing both the design complexity and the effects of video guidance lags. The DART design employs an indirect docking approach, in which the guidance position targets are defined using relative attitude information. Flight simulation results have proven the effectiveness of the video guidance design.

  4. Quantum mechanical resonances

    International Nuclear Information System (INIS)

    Cisneros S, A.; McIntosh, H.V.

    1982-01-01

    A discussion of the nature of quantum mechanical resonances is presented from the point of view of the spectral theory of operators. In the case of Bohr-Feshbach resonances, graphs are presented to illustrate the theory showing the decay of a doubly excited metastable state and the excitation of the resonance by an incident particle with proper energy. A characterization of resonances is given as well as a procedure to determine widths using the spectral density function. A sufficient condition is given for the validity of the Breit-Wigner formula for Bohr-Feshbach resonances. (author)

  5. Advances in imaging for oncology guidance

    International Nuclear Information System (INIS)

    Amies, Christopher J.

    2008-01-01

    Over the last 30 years major improvements in medical imaging have played a significant role to help advance the management of oncology diseases. These advances have covered the continuum of care from screening, diagnosis, staging, treatment planning and intervention. More recently image guided radiation therapy (IGRT) has placed sophisticated imaging closer to the treatment event. The opportunity to improve care seems obvious; however the clinical benefits of IGRT are at present not easily proven and yet contribute to the complexity of treatment and the rising costs of care. It is proposed that this is in part due to the present immaturity of IGRT technology development, which is predominantly determined by the challenge of achieving precise delivery of radiation in one or many episodes (fractions) for very different diseases. There is no single type or mode of imaging that will be suitable to address all radiotherapy guidance challenges whether defined by the general criteria identified for a specific disease or the unique characteristics encountered with an individual patient. Finally the wide adoption of this or any medical technology general requires the attainment of a sufficient degree of safety and efficiency. I present the challenges faced by industry as well as select interesting technology based solutions and concepts that may help advance the field of oncology guidance

  6. Cask system design guidance for robotic handling

    International Nuclear Information System (INIS)

    Griesmeyer, J.M.; Drotning, W.D.; Morimoto, A.K.; Bennett, P.C.

    1990-10-01

    Remote automated cask handling has the potential to reduce both the occupational exposure and the time required to process a nuclear waste transport cask at a handling facility. The ongoing Advanced Handling Technologies Project (AHTP) at Sandia National Laboratories is described. AHTP was initiated to explore the use of advanced robotic systems to perform cask handling operations at handling facilities for radioactive waste, and to provide guidance to cask designers regarding the impact of robotic handling on cask design. The proof-of-concept robotic systems developed in AHTP are intended to extrapolate from currently available commercial systems to the systems that will be available by the time that a repository would be open for operation. The project investigates those cask handling operations that would be performed at a nuclear waste repository facility during cask receiving and handling. The ongoing AHTP indicates that design guidance, rather than design specification, is appropriate, since the requirements for robotic handling do not place severe restrictions on cask design but rather focus on attention to detail and design for limited dexterity. The cask system design features that facilitate robotic handling operations are discussed, and results obtained from AHTP design and operation experience are summarized. The application of these design considerations is illustrated by discussion of the robot systems and their operation on cask feature mock-ups used in the AHTP project. 11 refs., 11 figs

  7. Guidance documents relating to landfills and contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Schomaker, N.B.; Zunt, D.A.

    1990-01-01

    The Environmental Protection Agency is developing and updating a series of Technical Guidance Documents to provide best engineering control technology to meet the needs of the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response Compensation and Liability Act (CERCLA), respectively. These documents are the compilation of the research efforts to date relating to containment of pollutants from waste disposal to the land as relates to residuals management. The specific areas of research being conducted under the RCRA land disposal program relates to laboratory, pilot and field validation studies in cover systems, waste leaching and solidification, liner systems and disposal facility evaluation. The specific areas of research being conducted under the CERCLA uncontrolled waste sites (Superfund) program relate to in situ treatment, solidification/stabilization for treating hazardous waste, combustion technologies, best demonstrated available technology (BDAT), on-site treatment technologies, emerging biosystems, expert systems, personnel health protection equipment, and site and situation assessment. The Guidance Documents are intended to assist both the regulated community and the permitting authorities, as well as the Program Offices, and Regions, as well as the states and other interested parties, with the latest information relevant to waste management.

  8. Axon guidance molecules in vascular patterning.

    Science.gov (United States)

    Adams, Ralf H; Eichmann, Anne

    2010-05-01

    Endothelial cells (ECs) form extensive, highly branched and hierarchically organized tubular networks in vertebrates to ensure the proper distribution of molecular and cellular cargo in the vertebrate body. The growth of this vascular system during development, tissue repair or in disease conditions involves the sprouting, migration and proliferation of endothelial cells in a process termed angiogenesis. Surprisingly, specialized ECs, so-called tip cells, which lead and guide endothelial sprouts, share many feature with another guidance structure, the axonal growth cone. Tip cells are motile, invasive and extend numerous filopodial protrusions sensing growth factors, extracellular matrix and other attractive or repulsive cues in their tissue environment. Axonal growth cones and endothelial tip cells also respond to signals belonging to the same molecular families, such as Slits and Roundabouts, Netrins and UNC5 receptors, Semaphorins, Plexins and Neuropilins, and Eph receptors and ephrin ligands. Here we summarize fundamental principles of angiogenic growth, the selection and function of tip cells and the underlying regulation by guidance cues, the Notch pathway and vascular endothelial growth factor signaling.

  9. Guidance of retinal axons in mammals.

    Science.gov (United States)

    Herrera, Eloísa; Erskine, Lynda; Morenilla-Palao, Cruz

    2017-11-26

    In order to navigate through the surrounding environment many mammals, including humans, primarily rely on vision. The eye, composed of the choroid, sclera, retinal pigmented epithelium, cornea, lens, iris and retina, is the structure that receives the light and converts it into electrical impulses. The retina contains six major types of neurons involving in receiving and modifying visual information and passing it onto higher visual processing centres in the brain. Visual information is relayed to the brain via the axons of retinal ganglion cells (RGCs), a projection known as the optic pathway. The proper formation of this pathway during development is essential for normal vision in the adult individual. Along this pathway there are several points where visual axons face 'choices' in their direction of growth. Understanding how these choices are made has advanced significantly our knowledge of axon guidance mechanisms. Thus, the development of the visual pathway has served as an extremely useful model to reveal general principles of axon pathfinding throughout the nervous system. However, due to its particularities, some cellular and molecular mechanisms are specific for the visual circuit. Here we review both general and specific mechanisms involved in the guidance of mammalian RGC axons when they are traveling from the retina to the brain to establish precise and stereotyped connections that will sustain vision. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  11. MR guidance and thermometry of percutaneous laser disc decompression in open MRI: an initial clinical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, Florian; Walter, Thula; Bucourt, Maximilian de; Freyhardt, Patrick; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Teichgraeber, Ulf K.M. [Charite, Humboldt-University Medical School, Department of Radiology, Berlin (Germany); Hartwig, Tony; Putzier, Michael; Strube, Patrick [Charite, Humboldt-University, Center for Musculoskeletal Surgery, Berlin (Germany); Bretschneider, Tina [University of Magdeburg, Department of Radiology, Magdeburg (Germany)

    2013-10-15

    To assess the feasibility, safety and efficacy of real-time MR guidance and thermometry of percutaneous laser disc decompression (PLDD). Twenty-four discs in 22 patients with chronic low-back and radicular pain were treated by PLDD using open 1.0-T magnetic-resonance imaging (MRI). A fluoroscopic proton-density-weighted turbo spin-echo (PDw TSE) sequence was used to position the laser fibre. Non-spoiled gradient-echo (GRE) sequences were employed for real-time thermal monitoring based on proton resonance frequency (PRF). Radicular pain was assessed over 6 months with a numerical rating scale (NRS). PLDD was technically successful in all cases, with adequate image quality for laser positioning. The PRF-based real-time temperature monitoring was found to be feasible in practice. After 6 months, 21 % reported complete remission of radicular pain, 63 % at least great pain relief and 74 % at least mild relief. We found a significant decrease in the NRS score between the pre-intervention and the 6-month follow-up assessment (P < 0.001). No major complications occurred; the single adverse event recorded, moderate motor impairment, resolved. Real-time MR guidance and PRF-based thermometry of PLDD in the lumbar spine under open 1.0-T MRI appears feasible, safe and effective and may pave the way to more precise operating procedures. (orig.)

  12. MR guidance and thermometry of percutaneous laser disc decompression in open MRI: an initial clinical investigation

    International Nuclear Information System (INIS)

    Streitparth, Florian; Walter, Thula; Bucourt, Maximilian de; Freyhardt, Patrick; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Teichgraeber, Ulf K.M.; Hartwig, Tony; Putzier, Michael; Strube, Patrick; Bretschneider, Tina

    2013-01-01

    To assess the feasibility, safety and efficacy of real-time MR guidance and thermometry of percutaneous laser disc decompression (PLDD). Twenty-four discs in 22 patients with chronic low-back and radicular pain were treated by PLDD using open 1.0-T magnetic-resonance imaging (MRI). A fluoroscopic proton-density-weighted turbo spin-echo (PDw TSE) sequence was used to position the laser fibre. Non-spoiled gradient-echo (GRE) sequences were employed for real-time thermal monitoring based on proton resonance frequency (PRF). Radicular pain was assessed over 6 months with a numerical rating scale (NRS). PLDD was technically successful in all cases, with adequate image quality for laser positioning. The PRF-based real-time temperature monitoring was found to be feasible in practice. After 6 months, 21 % reported complete remission of radicular pain, 63 % at least great pain relief and 74 % at least mild relief. We found a significant decrease in the NRS score between the pre-intervention and the 6-month follow-up assessment (P < 0.001). No major complications occurred; the single adverse event recorded, moderate motor impairment, resolved. Real-time MR guidance and PRF-based thermometry of PLDD in the lumbar spine under open 1.0-T MRI appears feasible, safe and effective and may pave the way to more precise operating procedures. (orig.)

  13. Resonance ionization of sputtered atoms: Progress toward a quantitative technique

    International Nuclear Information System (INIS)

    Calaway, W.F.; Pellin, M.J.; Young, C.E.; Whitten, J.E.; Gruen, D.M.; Coon, S.R.; Texas Univ., Austin, TX; Wiens, R.C.; Burnett, D.S.; Stingeder, G.; Grasserbauer, M.

    1992-01-01

    The combination of RIMS and ion sputtering has been heralded as the ideal means of quantitatively probing the surface of a solid. While several laboratories have demonstrated the extreme sensitivity of combining RIMS with sputtering, less effort has been devoted to the question of accuracy. Using the SARISA instrument developed at Argonne National Laboratory, a number of well-characterized metallic samples have been analyzed. Results from these determinations have been compared with data obtained by several other analytical methods. One significant finding is that impurity measurements down to ppb levels in metal matrices can be made quantitative by employing polycrystalline metal foils as calibration standards. This discovery substantially reduces the effort required for quantitative analysis since a single standard can be used for determining concentrations spanning nine orders of magnitude

  14. Geothermal progress monitor. Progress report No. 1

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    Progress is reported on the following: electrical uses, direct-heat uses, drilling activities, leases, geothermal loan guarantee program, general activities, and legal, institutional, and regulatory activites. (MHR)

  15. Microstrip resonators for electron paramagnetic resonance experiments

    Science.gov (United States)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  16. Microstrip resonators for electron paramagnetic resonance experiments.

    Science.gov (United States)

    Torrezan, A C; Mayer Alegre, T P; Medeiros-Ribeiro, G

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5 x 10(10) spins/GHz(1/2) despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  17. Orion Powered Flight Guidance Burn Options for Near Term Exploration

    Science.gov (United States)

    Fill, Tom; Goodman, John; Robinson, Shane

    2018-01-01

    NASA's Orion exploration spacecraft will fly more demanding mission profiles than previous NASA human flight spacecraft. Missions currently under development are destined for cislunar space. The EM-1 mission will fly unmanned to a Distant Retrograde Orbit (DRO) around the Moon. EM-2 will fly astronauts on a mission to the lunar vicinity. To fly these missions, Orion requires powered flight guidance that is more sophisticated than the orbital guidance flown on Apollo and the Space Shuttle. Orion's powered flight guidance software contains five burn guidance options. These five options are integrated into an architecture based on a proven shuttle heritage design, with a simple closed-loop guidance strategy. The architecture provides modularity, simplicity, versatility, and adaptability to future, yet-to-be-defined, exploration mission profiles. This paper provides a summary of the executive guidance architecture and details the five burn options to support both the nominal and abort profiles for the EM-1 and EM-2 missions.

  18. Trajectory reshaping based guidance with impact time and angle constraints

    Directory of Open Access Journals (Sweden)

    Zhao Yao

    2016-08-01

    Full Text Available This study presents a novel impact time and angle constrained guidance law for homing missiles. The guidance law is first developed with the prior-assumption of a stationary target, which is followed by the practical extension to a maneuvering target scenario. To derive the closed-form guidance law, the trajectory reshaping technique is utilized and it results in defining a specific polynomial function with two unknown coefficients. These coefficients are determined to satisfy the impact time and angle constraints as well as the zero miss distance. Furthermore, the proposed guidance law has three additional guidance gains as design parameters which make it possible to adjust the guided trajectory according to the operational conditions and missile’s capability. Numerical simulations are presented to validate the effectiveness of the proposed guidance law.

  19. Scattering processes and resonances from lattice QCD

    Science.gov (United States)

    Briceño, Raúl A.; Dudek, Jozef J.; Young, Ross D.

    2018-04-01

    The vast majority of hadrons observed in nature are not stable under the strong interaction; rather they are resonances whose existence is deduced from enhancements in the energy dependence of scattering amplitudes. The study of hadron resonances offers a window into the workings of quantum chromodynamics (QCD) in the low-energy nonperturbative region, and in addition many probes of the limits of the electroweak sector of the standard model consider processes which feature hadron resonances. From a theoretical standpoint, this is a challenging field: the same dynamics that binds quarks and gluons into hadron resonances also controls their decay into lighter hadrons, so a complete approach to QCD is required. Presently, lattice QCD is the only available tool that provides the required nonperturbative evaluation of hadron observables. This article reviews progress in the study of few-hadron reactions in which resonances and bound states appear using lattice QCD techniques. The leading approach is described that takes advantage of the periodic finite spatial volume used in lattice QCD calculations to extract scattering amplitudes from the discrete spectrum of QCD eigenstates in a box. An explanation is given of how from explicit lattice QCD calculations one can rigorously garner information about a variety of resonance properties, including their masses, widths, decay couplings, and form factors. The challenges which currently limit the field are discussed along with the steps being taken to resolve them.

  20. The International Safety Framework for nuclear power source applications in outer space-Useful and substantial guidance

    Science.gov (United States)

    Summerer, L.; Wilcox, R. E.; Bechtel, R.; Harbison, S.

    2015-06-01

    generic to remain relevantly independent of technological progress, of national organisational setups and of space mission types. Implementing its guidance therefore leaves room for interpretation and adaptation. Relying on reported practices, we analyse the guidance particularly relevant to engineers and space mission designers.

  1. Existing ingestion guidance: Problems and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Mooney, Robert R; Ziegler, Gordon L; Peterson, Donald S [Environmental Radiation Section, Division of Radiation Protection, WA (United States)

    1989-09-01

    Washington State has been developing plans and procedures for responding to nuclear accidents since the early 1970s. A key part of this process has been formulating a method for calculating ingestion pathway concentration guides (CGs). Such a method must be both technically sound and easy to use. This process has been slow and frustrating. However, much technical headway has been made in recent years, and hopefully the experience of the State of Washington will provide useful insight to problems with the existing guidance. Several recommendations are offered on ways to deal with these problems. In January 1986, the state held an ingestion pathway exercise which required the determination of allowed concentrations of isotopes for various foods, based upon reactor source term and field data. Objectives of the exercise were not met because of the complexity of the necessary calculations. A major problem was that the allowed concentrations had to be computed for each isotope and each food group, given assumptions on the average diet. To solve problems identified during that exercise, Washington developed, by March 1986, partitioned CGs. These CGs apportioned doses from each food group for an assumed mix of radionuclides expected to result from a reactor accident. This effort was therefore in place just in time for actual use during the Chernobyl fallout episode in May 1986. This technique was refined and described in a later report and presented at the 1987 annual meeting of the Health Physics Society. Realizing the technical weaknesses which still existed and a need to simplify the numbers for decision makers, Washington State has been developing computer methods to quickly calculate, from an accident specific relative mix of isotopes, CGs which allow a single radionuclide concentration for all food groups. This latest approach allows constant CGs for different periods of time following the accident, instead of peak CGs, which are good only for a short time after the

  2. Existing ingestion guidance: Problems and recommendations

    International Nuclear Information System (INIS)

    Mooney, Robert R.; Ziegler, Gordon L.; Peterson, Donald S.

    1989-01-01

    Washington State has been developing plans and procedures for responding to nuclear accidents since the early 1970s. A key part of this process has been formulating a method for calculating ingestion pathway concentration guides (CGs). Such a method must be both technically sound and easy to use. This process has been slow and frustrating. However, much technical headway has been made in recent years, and hopefully the experience of the State of Washington will provide useful insight to problems with the existing guidance. Several recommendations are offered on ways to deal with these problems. In January 1986, the state held an ingestion pathway exercise which required the determination of allowed concentrations of isotopes for various foods, based upon reactor source term and field data. Objectives of the exercise were not met because of the complexity of the necessary calculations. A major problem was that the allowed concentrations had to be computed for each isotope and each food group, given assumptions on the average diet. To solve problems identified during that exercise, Washington developed, by March 1986, partitioned CGs. These CGs apportioned doses from each food group for an assumed mix of radionuclides expected to result from a reactor accident. This effort was therefore in place just in time for actual use during the Chernobyl fallout episode in May 1986. This technique was refined and described in a later report and presented at the 1987 annual meeting of the Health Physics Society. Realizing the technical weaknesses which still existed and a need to simplify the numbers for decision makers, Washington State has been developing computer methods to quickly calculate, from an accident specific relative mix of isotopes, CGs which allow a single radionuclide concentration for all food groups. This latest approach allows constant CGs for different periods of time following the accident, instead of peak CGs, which are good only for a short time after the

  3. Research progress of functional MRI in depression

    International Nuclear Information System (INIS)

    Xie Shenghui; Niu Guangming; Han Xiaodong; Qiao Pengfei

    2013-01-01

    The mood disorders of depression are associated with abnormalities of brain structure and function, and exploring their pathological mechanism has important significance for the choice of treatment and the curative effect evaluation. In recent years, the research of MRI on brain structure and function of depression has made great progress, especially in functional magnetic resonance imaging (fMRI). fMRI can detect the functional change in real time, and also can display the activity of brain and changes in the nerve pathways in patients with depression. This article summarizes the present research situation and progress of MRI in the diagnosis of depression. (authors)

  4. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  5. Automatic guidance and control laws for helicopter obstacle avoidance

    Science.gov (United States)

    Cheng, Victor H. L.; Lam, T.

    1992-01-01

    The authors describe the implementation of a full-function guidance and control system for automatic obstacle avoidance in helicopter nap-of-the-earth (NOE) flight. The guidance function assumes that the helicopter is sufficiently responsive so that the flight path can be readily adjusted at NOE speeds. The controller, basically an autopilot for following the derived flight path, was implemented with parameter values to control a generic helicopter model used in the simulation. Evaluation of the guidance and control system with a 3-dimensional graphical helicopter simulation suggests that the guidance has the potential for providing good and meaningful flight trajectories.

  6. Integrating mechanisms of visual guidance in naturalistic language production.

    Science.gov (United States)

    Coco, Moreno I; Keller, Frank

    2015-05-01

    Situated language production requires the integration of visual attention and linguistic processing. Previous work has not conclusively disentangled the role of perceptual scene information and structural sentence information in guiding visual attention. In this paper, we present an eye-tracking study that demonstrates that three types of guidance, perceptual, conceptual, and structural, interact to control visual attention. In a cued language production experiment, we manipulate perceptual (scene clutter) and conceptual guidance (cue animacy) and measure structural guidance (syntactic complexity of the utterance). Analysis of the time course of language production, before and during speech, reveals that all three forms of guidance affect the complexity of visual responses, quantified in terms of the entropy of attentional landscapes and the turbulence of scan patterns, especially during speech. We find that perceptual and conceptual guidance mediate the distribution of attention in the scene, whereas structural guidance closely relates to scan pattern complexity. Furthermore, the eye-voice span of the cued object and its perceptual competitor are similar; its latency mediated by both perceptual and structural guidance. These results rule out a strict interpretation of structural guidance as the single dominant form of visual guidance in situated language production. Rather, the phase of the task and the associated demands of cross-modal cognitive processing determine the mechanisms that guide attention.

  7. Ultrasound Guidance as a Rescue Technique for Peripheral Intravenous Cannulation

    National Research Council Canada - National Science Library

    Pappas, Nancy L; Michaud, Terese E; Wolbers, Russell M; Steward, James C; Fevurly, Thomas A; Samolitis, Timothy J; Shoneboom, Bruce A; Watts, Dorraine D

    2006-01-01

    .... Ultrasound guidance has shown efficacy in expediting the cannulation of central veins, but there is limited information on its utility in facilitating cannulation in peripheral veins, particularly...

  8. Guidance for Facilities on Risk Management Programs (RMP)

    Science.gov (United States)

    Includes supplemental guidance specific to ammonia refrigeration, wastewater treatment, propane storage, warehouses, chemical distributors, offsite consequence analysis, retail agriculture, applicability of program levels, prevention, emergency response.

  9. A Preliminary Experience with Use of Intraoperative Magnetic Resonance Imaging in Thalamic Glioma Surgery: A Case Series of 38 Patients.

    Science.gov (United States)

    Zheng, Xuan; Xu, Xinghua; Zhang, Hui; Wang, Qun; Ma, Xiaodong; Chen, Xiaolei; Sun, Guochen; Zhang, Jiashu; Jiang, Jinli; Xu, Bainan; Zhang, Jun

    2016-05-01

    Thalamic gliomas are rare tumors that constitute 1%-5% of all central nervous system tumors. Despite advanced techniques and equipment, surgical resection remains challenging because of the vital structures adjacent to the tumor. Intraoperative magnetic resonance imaging (MRI) might play an active role during brain tumor surgery because it compensates for brain shift or operation-induced hemorrhage, which are challenging issues for neurosurgeons. We reviewed 38 patients treated surgically under intraoperative MRI guidance between January 2008 and July 2015 at our center. Preoperative, intraoperative, and postoperative MRI scans were reviewed. Preoperative and postoperative motor power, morbidity and mortality, resection rate, surgical approach, pathologic results, and patient demographics were also reviewed. Mean patient age was 37 years ± 18; 12 patients were included in the low-grade group, and 26 patients were included in the high-grade group. Under intraoperative MRI guidance, the gross total resection rate was increased from 16 (42.1%) to 26 (68.4%), and the near-total or subtotal resection rate was increased from 5 (13.2%) to 9 (23.7%). Hematoma formation was discovered in 3 patients on intraoperative MRI scan; each patient underwent a hemostatic operation immediately. With improvements in neurosurgical techniques and equipment, surgical resection is considered feasible in patients with thalamic gliomas. Intraoperative MRI may be helpful in achieving the maximal resection rate with minimal surgical-related morbidity. However, because of severe disease progression, the overall prognosis is unfavorable. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Development of the severe accident management guidance module for the SATS training simulator

    International Nuclear Information System (INIS)

    Kim, K. R.; Park, S. H.; Kim, D. H.

    2004-01-01

    Recently KAERI has developed severe accident management guidance to establish Korea standard severe accident management system. On the other hand PC-based severe accident training simulator SATS has been developed, which uses MELCOR computing code as the simulation engine. SATS graphically displays and simulates the severe accident progression with interactive user inputs. The control capability of SATS makes a severe accident training course more interesting and effective. In this paper the development and functions of HyperKAMG module are explained. Furthermore easiness and effectiveness of the HyperKAMG-SATS system in severe accident management are described

  11. Commercial radioactive waste minimization program development guidance

    International Nuclear Information System (INIS)

    Fischer, D.K.

    1991-01-01

    This document is one of two prepared by the EG ampersand G Idaho, Inc., Waste Management Technical Support Program Group, National Low-Level Waste Management Program Unit. One of several Department of Energy responsibilities stated in the Amendments Act of 1985 is to provide technical assistance to compact regions Host States, and nonmember States (to the extent provided in appropriations acts) in establishing waste minimization program plans. Technical assistance includes, among other things, the development of technical guidelines for volume reduction options. Pursuant to this defined responsibility, the Department of Energy (through EG ampersand G Idaho, Inc.) has prepared this report, which includes guidance on defining a program, State/compact commission participation, and waste minimization program plans

  12. Improvements in inservice testing regulatory guidance

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, P.L.

    1996-12-01

    Over the last few years, the NRC has issued guidance to licensees toward improving the quality of requests for relief or alternatives to the code requirements and bring some measure of consistency to the implementation of the code requirements. Based on the majority of the recent submittals, the overall quality has improved. If all of the steps in the internal process for responding to the requests are timely, the review of an updated program can be completed in six to nine months. When a single or only a few requests are submitted, the staff is generally able to complete an evaluation in less than three months. When schedules are related to outages or exigent circumstances, the NRC responds accordingly. The improvements in schedules can be attributed to publication of staff guideline documents, licensees` efforts in preparing more complete descriptions and justification and an increase in the number of NRC technical staff reviewers assigned to IST.

  13. Improvements in inservice testing regulatory guidance

    International Nuclear Information System (INIS)

    Campbell, P.L.

    1996-01-01

    Over the last few years, the NRC has issued guidance to licensees toward improving the quality of requests for relief or alternatives to the code requirements and bring some measure of consistency to the implementation of the code requirements. Based on the majority of the recent submittals, the overall quality has improved. If all of the steps in the internal process for responding to the requests are timely, the review of an updated program can be completed in six to nine months. When a single or only a few requests are submitted, the staff is generally able to complete an evaluation in less than three months. When schedules are related to outages or exigent circumstances, the NRC responds accordingly. The improvements in schedules can be attributed to publication of staff guideline documents, licensees' efforts in preparing more complete descriptions and justification and an increase in the number of NRC technical staff reviewers assigned to IST

  14. Technical guidance for siting criteria development

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, D.C.; Sprung, J.L.; Alpert, D.J.; Diegert, K.; Ostmeyer, R.M.; Ritchie, L.T.; Strip, D.R.; Johnson, J.D.; Hansen, K.; Robinson, J.

    1982-12-01

    Technical guidance to support the formulation and comparison of possible siting criteria for nuclear power plants has been developed in four areas: (1) consequences of hypothetical severe nuclear-power-plant accidents, (2) characteristics of population distributions about current reactor sites, (3) site availability within the continental United States, and (4) socioeconomic impacts of reactor siting. The impact on consequences of source-term magnitude, meteorology, population distribution, and emergency response have been analyzed. Population distributions about current sites were analyzed to identify statistical characteristics, time trends, and regional differences. A site-availability data bank was constructed for the continential United States. The data bank contains information about population densities, seismicity, topography, water availability, and land-use restrictions. Finally, the socioeconomic impacts of rural-industrialization projects, energy boomtowns, and nuclear power plants were examined to determine their nature, magnitude, and dependence on site demography and remoteness.

  15. GUIDANCE ON SELECTING AGE GROUPS FOR ...

    Science.gov (United States)

    This guidance document provides a set of early-lifestage age groups for Environmental Protection Agency scientists to consider when assessing children’s exposure to environmental contaminants and the resultant potential dose. These recommended age groups are based on current understanding of differences in behavior and physiology which may impact exposures in children. A consistent set of early-life age groups, supported by an underlying scientific rationale, is expected to improve Agency exposure and risk assessments for children by increasing the consistency and comparability of risk assessments across the Agency; by improving accuracy and transparency in assessments for those cases where current practice might too broadly combine behaviorally and physiologically disparate age groups; and by fostering a consistent approach to future exposure surveys and monitoring efforts to generate improved exposure factors for children. see description

  16. Technical guidance for siting criteria development

    International Nuclear Information System (INIS)

    Aldrich, D.C.; Sprung, J.L.; Alpert, D.J.

    1982-12-01

    Technical guidance to support the formulation and comparison of possible siting criteria for nuclear power plants has been developed in four areas: (1) consequences of hypothetical severe nuclear-power-plant accidents, (2) characteristics of population distributions about current reactor sites, (3) site availability within the continental United States, and (4) socioeconomic impacts of reactor siting. The impact on consequences of source-term magnitude, meteorology, population distribution, and emergency response have been analyzed. Population distributions about current sites were analyzed to identify statistical characteristics, time trends, and regional differences. A site-availability data bank was constructed for the continential United States. The data bank contains information about population densities, seismicity, topography, water availability, and land-use restrictions. Finally, the socioeconomic impacts of rural-industrialization projects, energy boomtowns, and nuclear power plants were examined to determine their nature, magnitude, and dependence on site demography and remoteness

  17. Chief Inspector's guidance to inspectors: combustion processes

    International Nuclear Information System (INIS)

    1992-01-01

    This Note is issued by the Chief Inspector of Her Majesty's Inspectorate of Pollution (HMIP) as one of a series providing guidance for processes prescribed for integrated pollution control in Regulations made under Section 2 of the United Kingdom Environmental Protection Act 1990. It covers the burning of solid fuel manufactured from or comprised of tyres, tyre rubber or similar rubber waste primarily for the purpose of producing energy, in an appliance with a net rated thermal input of 3 megawatts or more. The note includes: a list of prescribed substances most likely to be present in releases to the environment by the processes considered; release limits for release to air, water and land; an outline of techniques for pollution abatement; monitoring requirements. (Author)

  18. D ampersand D screening risk evaluation guidance

    International Nuclear Information System (INIS)

    Robers, S.K.; Golden, K.M.; Wollert, D.A.

    1995-09-01

    The Screening Risk Evaluation (SRE) guidance document is a set of guidelines provided for the uniform implementation of SREs performed on decontamination and decommissioning (D ampersand D) facilities. Although this method has been developed for D ampersand D facilities, it can be used for transition (EM-60) facilities as well. The SRE guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the current risk to human health and the environment, exterior to the building, from ongoing or probable releases within a one-year time period. The Worker Exposure Index (WEI) calculates the current risk to workers, occupants and visitors inside contaminated D ampersand D facilities due to contaminant exposure. The Future Release Index (FRI) calculates the hypothetical risk of future releases of contaminants, after one year, to human health and the environment. The Physical Hazards Index (PHI) calculates the risks to human health due to factors other than that of contaminants. Criticality is approached as a modifying factor to the entire SRE, due to the fact that criticality issues are strictly regulated under DOE. Screening risk results will be tabulated in matrix form, and Total Risk will be calculated (weighted equation) to produce a score on which to base early action recommendations. Other recommendations from the screening risk scores will be made based either on individual index scores or from reweighted Total Risk calculations. All recommendations based on the SRE will be made based on a combination of screening risk scores, decision drivers, and other considerations, as determined on a project-by-project basis

  19. D & D screening risk evaluation guidance

    Energy Technology Data Exchange (ETDEWEB)

    Robers, S.K.; Golden, K.M.; Wollert, D.A.

    1995-09-01

    The Screening Risk Evaluation (SRE) guidance document is a set of guidelines provided for the uniform implementation of SREs performed on decontamination and decommissioning (D&D) facilities. Although this method has been developed for D&D facilities, it can be used for transition (EM-60) facilities as well. The SRE guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the current risk to human health and the environment, exterior to the building, from ongoing or probable releases within a one-year time period. The Worker Exposure Index (WEI) calculates the current risk to workers, occupants and visitors inside contaminated D&D facilities due to contaminant exposure. The Future Release Index (FRI) calculates the hypothetical risk of future releases of contaminants, after one year, to human health and the environment. The Physical Hazards Index (PHI) calculates the risks to human health due to factors other than that of contaminants. Criticality is approached as a modifying factor to the entire SRE, due to the fact that criticality issues are strictly regulated under DOE. Screening risk results will be tabulated in matrix form, and Total Risk will be calculated (weighted equation) to produce a score on which to base early action recommendations. Other recommendations from the screening risk scores will be made based either on individual index scores or from reweighted Total Risk calculations. All recommendations based on the SRE will be made based on a combination of screening risk scores, decision drivers, and other considerations, as determined on a project-by-project basis.

  20. Recent progress in fusion gyrotron development

    International Nuclear Information System (INIS)

    Shively, J.F.; Stone, D.S.

    1981-01-01

    The gyrotron, a microwave tube capable of producing high power output at millimeter wavelengths, has recently found applications for electron cyclotron resonance heating of plasmas in controlled thermonuclear fusion reactor experiments. This paper describes work in progress to develop a gyrotron oscillator to deliver 200 kW CW at 60 GHz (/lambda/sub //. 5 mm). A pulsed oscillator is described which produced over 200 kw peak power. A CW oscillator is under construction. The latest experimental results are presented

  1. Nanodiamond graphitization: a magnetic resonance study

    International Nuclear Information System (INIS)

    Panich, A M; Shames, A I; Sergeev, N A; Olszewski, M; McDonough, J K; Mochalin, V N; Gogotsi, Y

    2013-01-01

    We report on the first nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) study of the high-temperature nanodiamond-to-onion transformation. 1 H, 13 C NMR and EPR spectra of the initial nanodiamond samples and those annealed at 600, 700, 800 and 1800 ° C were measured. For the samples annealed at 600 to 800 ° C, our NMR data reveal the early stages of the surface modification, as well as a progressive increase in sp 2 carbon content with increased annealing temperature. Such quantitative experimental data were recorded for the first time. These findings correlate with EPR data on the sensitivity of the dangling bond EPR line width to air content, progressing with rising annealing temperature, that evidences consequent graphitization of the external layers of the diamond core. The sample annealed at 1800 ° C shows complete conversion of nanodiamond particles into carbon onions. (paper)

  2. Atlas of neutron resonances

    CERN Document Server

    Mughabghab, Said

    2018-01-01

    Atlas of Neutron Resonances: Resonance Properties and Thermal Cross Sections Z= 1-60, Sixth Edition, contains an extensive list of detailed individual neutron resonance parameters for Z=1-60, as well as thermal cross sections, capture resonance integrals, average resonance parameters and a short survey of the physics of thermal and resonance neutrons. The long introduction contains: nuclear physics formulas aimed at neutron physicists; topics of special interest such as valence neutron capture, nuclear level density parameters, and s-, p-, and d-wave neutron strength functions; and various comparisons of measured quantities with the predictions of nuclear models, such as the optical model. As in the last edition, additional features have been added to appeal to a wider spectrum of users. These include: spin-dependent scattering lengths that are of interest to solid-state physicists, nuclear physicists and neutron evaluators; calculated and measured Maxwellian average 5-keV and 30-keV capture cross sections o...

  3. Low-loss single-mode hollow-core fiber with anisotropic anti-resonant elements

    DEFF Research Database (Denmark)

    Habib, Selim; Bang, Ole; Bache, Morten

    2016-01-01

    A hollow-core fiber using anisotropic anti-resonant tubes in thecladding is proposed for low loss and effectively single-mode guidance. We show that the loss performance and higher-order mode suppression is significantly improved by using symmetrically distributed anisotropic antiresonant tubes i...

  4. Radiative decays of resonances on the lattice

    International Nuclear Information System (INIS)

    Agadjanov, Andria; Bernard, Véronique; Meißner, Ulf-G.; Rusetsky, Akaki

    2016-01-01

    We discuss a generalization of the Lüscher approach to the calculation of the matrix elements of the unstable states. A theoretical framework for the lattice extraction of the ΔNγ* transition form factors is formulated. The procedure to measure the form factors at the resonance pole is given. The current theoretical progress on the B → K*γ* decays is briefly summarized

  5. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  6. Electron paramagnetic resonance

    CERN Document Server

    Al'tshuler, S A

    2013-01-01

    Electron Paramagnetic Resonance is a comprehensive text on the field of electron paramagnetic resonance, covering both the theoretical background and the results of experiment. This book is composed of eight chapters that cover theoretical materials and experimental data on ionic crystals, since these are the materials that have been most extensively studied by the methods of paramagnetic resonance. The opening chapters provide an introduction to the basic principles of electron paramagnetic resonance and the methods of its measurement. The next chapters are devoted to the theory of spectra an

  7. Ramifide resonators for cyclotrons

    International Nuclear Information System (INIS)

    Smirnov, Yu.V.

    2000-01-01

    The resonators with the conductors ramified form for cyclotrons are systematized and separated into the self-contained class - the ramified resonators for cyclotrons (Carr). The ramified resonators are compared with the quarter-wave and half-wave nonramified resonators, accomplished from the transmitting lines fragments. The CRR are classified into two types: ones with the additional structural element, switched in parallel and in series. The CRR may include several additional structural elements. The CRR calculations may be concluded by analytical methods - the method of matrix calculation or the method of telegraph equations and numerical methods - by means of the ISFEL3D, MAFIA and other programs [ru

  8. Contextual Cueing Improves Attentional Guidance, Even When Guidance Is Supposedly Optimal

    OpenAIRE

    Harris, A. M.; Remington, R. W.

    2017-01-01

    Visual search through previously encountered contexts typically produces reduced reaction times compared with search through novel contexts. This contextual cueing benefit is well established, but there is debate regarding its underlying mechanisms. Eye-tracking studies have consistently shown reduced number of fixations with repetition, supporting improvements in attentional guidance as the source of contextual cueing. However, contextual cueing benefits have been shown in conditions in whic...

  9. ADM guidance-Ceramics: guidance to the use of fractography in failure analysis of brittle materials.

    Science.gov (United States)

    Scherrer, Susanne S; Lohbauer, Ulrich; Della Bona, Alvaro; Vichi, Alessandro; Tholey, Michael J; Kelly, J Robert; van Noort, Richard; Cesar, Paulo Francisco

    2017-06-01

    To provide background information and guidance as to how to use fractography accurately, a powerful tool for failure analysis of dental ceramic structures. An extended palette of qualitative and quantitative fractography is provided, both for in vivo and in vitro fracture surface analyses. As visual support, this guidance document will provide micrographs of typical critical ceramic processing flaws, differentiating between pre- versus post sintering cracks, grinding damage related failures and occlusal contact wear origins and of failures due to surface degradation. The documentation emphasizes good labeling of crack features, precise indication of the direction of crack propagation (dcp), identification of the fracture origin, the use of fractographic photomontage of critical flaws or flaw labeling on strength data graphics. A compilation of recommendations for specific applications of fractography in Dentistry is also provided. This guidance document will contribute to a more accurate use of fractography and help researchers to better identify, describe and understand the causes of failure, for both clinical and laboratory-scale situations. If adequately performed at a large scale, fractography will assist in optimizing the methods of processing and designing of restorative materials and components. Clinical failures may be better understood and consequently reduced by sending out the correct message regarding the fracture origin in clinical trials. Copyright © 2017 The Academy of Dental Materials. All rights reserved.

  10. National All-Age Career Guidance Services: Evidence and Issues

    Science.gov (United States)

    Watts, A. G.

    2010-01-01

    The three major national all-age career guidance services--in New Zealand, Scotland and Wales--have been reviewed using an adaptation of the methodology adopted in the OECD Career Guidance Policy Review. The main features of the three services are summarised, and some key differences and distinctive strengths are outlined. The alternative approach…

  11. 32 CFR 147.6 - Guidance D-Sexual behavior.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Guidance D-Sexual behavior. 147.6 Section 147.6... Guidance D—Sexual behavior. (a) The concern. Sexual behavior is a security concern if it involves a... security concerns raised by sexual behavior. (b) Conditions that could raise a security concern and may be...

  12. The Need for a Functional Guidance and Counselling Programme in ...

    African Journals Online (AJOL)

    The paper examines the need for a functional guidance and counselling programme in Nigeria's primary school with particular reference to developmental guidance and vocational development. Primary school counselling naturally, must be concerned with consulting, appraisal, counselling, placement, public relation and ...

  13. 78 FR 9054 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2013-02-07

    ... NIOSH-144] Issuance of Final Guidance Publication AGENCY: National Institute for Occupational Safety and... Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The National Institute...), announces the availability of the following publication: ``NIOSH Criteria for a Recommended Standard...

  14. 76 FR 22106 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2011-04-20

    ... NIOSH-033] Issuance of Final Guidance Publication AGENCY: National Institute for Occupational Safety and... Health and Human Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The... (CDC) announces the availability of the following publication: NIOSH Current Intelligence Bulletin 63...

  15. 78 FR 78963 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2013-12-27

    ... CDC-2013-0001, NIOSH 134-B] Issuance of Final Guidance Publication AGENCY: National Institute for... Health and Human Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The... Prevention (CDC), announces the availability of the following publication: ``Protecting the Nanotechnology...

  16. 78 FR 66936 - Issuance of Final Guidance Publication

    Science.gov (United States)

    2013-11-07

    ... NIOSH-156] Issuance of Final Guidance Publication AGENCY: National Institute for Occupational Safety and... Services (HHS). ACTION: Notice of issuance of final guidance publication. SUMMARY: The National Institute...), announces the availability of the following publication: ``Current Intelligence Bulletin 66--Derivation of...

  17. Design of guidance laws for lunar pinpoint soft landing

    NARCIS (Netherlands)

    Guo, J.; Han, C.

    2009-01-01

    Future lunar missions ask for the capability to perform precise Guidance, Navigation and Control (GNC) to the selected landing sites on the lunar surface. This paper studies the guidance issues for the lunar pinpoint soft landing problem. The primary contribution of this paper is the design of

  18. Radon: guidance on protective measures for new dwellings

    International Nuclear Information System (INIS)

    1991-01-01

    This report gives guidance for reducing the presence of radon in new dwellings and hence reducing the risk to occupants of exposure to radon. This is a follow-up to the interim guidance of 1988. The report provides comprehensive practical details on the methods of protection including both primary and secondary measures. (UK)

  19. 76 FR 75771 - Emergency Planning Guidance for Nuclear Power Plants

    Science.gov (United States)

    2011-12-05

    ... Guidance for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Issuance of NUREG... Support of Nuclear Power Plants;'' NSIR/DPR-ISG-01, ``Interim Staff Guidance Emergency Planning for Nuclear Power Plants;'' and NUREG/CR-7002, ``Criteria for Development of Evacuation Time Estimate Studies...

  20. Career Guidance for Student Nurses: An Unmet Need.

    Science.gov (United States)

    Marsland, Louise

    1996-01-01

    A British survey of 1,164 new registered nurses (1,015 responses) asked about career guidance they received related to applying for their first job, taking postbasic courses, and making longer-term plans. Few received much guidance, especially about individual career planning. (SK)

  1. Interdisciplinarity in Vocational Guidance: An Action Theory Perspective

    Science.gov (United States)

    Valach, Ladislav; Young, Richard A.

    2009-01-01

    In addressing the issue of interdisciplinary research in vocational guidance, twelve propositions important for understanding the vocational guidance process as joint, goal-directed action are presented. They address the encounter between client and counsellor leading to relational ethics, the relevance of everyday action theory and methods for…

  2. Guidance for Older Workers in Denmark and Spain

    Science.gov (United States)

    Plant, Peter; Lopez-Sanchez, Maria Jose

    2011-01-01

    Guidance has a role to play in helping older workers to lead meaningful and fruitful lives; inside, outside, on the edge of the labour market, or in voluntary work with examples from two very different European countries: Denmark and Spain. This paper aims to draw attention to older workers guidance from an economic policy approach. It will be…

  3. Quality assurance and evidence in career guidance in Europe

    DEFF Research Database (Denmark)

    Plant, Peter

    2011-01-01

    Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected.......Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected....

  4. 76 FR 9529 - Migratory Birds; Draft Eagle Conservation Plan Guidance

    Science.gov (United States)

    2011-02-18

    ...-1231-9BPP] RIN 1018-AX53 Migratory Birds; Draft Eagle Conservation Plan Guidance AGENCY: Fish and... mail to: Attention: Eagle Conservation Plan Guidance; Division of Migratory Bird Management; U.S. Fish... implementing statutes including the Bald and Golden Eagle Protection Act (BGEPA), the Migratory Bird Treaty Act...

  5. Career Guidance and Social Exclusion: A Cautionary Tale.

    Science.gov (United States)

    Watts, A. G.

    2001-01-01

    Examines the relationship of career guidance to public-policy interventions designed to address social exclusion. Analyzes the nature and origin of the concept of social exclusion and reviews the roles of career guidance in response to it, particularly in relation to young people who have dropped out of formal education or are at high risk of…

  6. Environmental Guidance Program Reference Book: American Indian Religious Freedom Act

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    This Reference Book contains a copy of the American Indian Religious Freedom Act and guidance for DOE compliance with the statute. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically.

  7. Factors affecting guidance and counseling programme in primary ...

    African Journals Online (AJOL)

    The objective of this study was to establish the factors that affect guidance and counseling in primary schools. Guidance and counseling seems not to be adequately helping pupils with physical and psychological problems in Nairobi province of Kenya. Many primary schools are faced with indiscipline and poor performance ...

  8. An Evaluation of Guidance and Counselling Services Offered to ...

    African Journals Online (AJOL)

    This paper sought to evaluate the guidance and counselling services offered to students in Gwanda urban and peri-urban secondary schools. Guidance and counselling is regarded as a programme and service in the education system, providing advice with regards to students' education, career planning, social issues or ...

  9. An Assessment of the Implementation of Guidance and Counselling ...

    African Journals Online (AJOL)

    This paper is based on a research study carried out by the author in 2003. The study assessed how Guidance and Counselling Programmes were being implemented in Gweru urban secondary schools at Ordinary level. The assessment focused on such key elements in Guidance and Counselling as time allocation, ...

  10. Students' perception of guidance and counselling services offered in ...

    African Journals Online (AJOL)

    Many students of tertiary institutions including Colleges of Education are young adults who feel more concerned about getting a job, making a home and continuing higher education. These concerns require proper guidance The general purpose of this study therefore was to find out the perception of students on guidance ...

  11. 75 FR 59268 - Draft Guidance for Industry: Acidified Foods; Availability

    Science.gov (United States)

    2010-09-27

    ... fermented dairy products, such as yogurt, belong to a separate category that is not relevant to the... the draft guidance, processors of non-acidified foods (e.g., some acid foods or fermented foods) who... regulations. Under the draft guidance, processors of acid foods and fermented foods who conclude that such...

  12. Thinking Differently about Guidance: Power, Children's Autonomy and Democratic Environments

    Science.gov (United States)

    Millei, Zsuzsa

    2012-01-01

    This article critiques guidance approaches to discipline, that are employed in early childhood environments with an aim to create democratic environments for children, and as part of "good" practices. Advocates of guidance claim that this is a more humane or democratic approach to discipline that empowers children, and therefore, power…

  13. Controlling interactions between highly magnetic atoms with Feshbach resonances.

    Science.gov (United States)

    Kotochigova, Svetlana

    2014-09-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic (7)S3 chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on dysprosium and erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P-states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  14. Progressive Pigmentary Purpura

    Science.gov (United States)

    ... Category: Share: Yes No, Keep Private Progressive Pigmentary Purpura Share | Progressive pigmentary purpura (we will call it PPP) is a group ... conditions ( Schamberg's disease , Lichenoid dermatitis of Gourgerot-Blum, purpura annularis telangiectodes of Majocchi and Lichen aureus). Schamberg's ...

  15. Primary Progressive Aphasia

    Science.gov (United States)

    ... which cause different symptoms. Semantic variant primary progressive aphasia Symptoms include these difficulties: Comprehending spoken or written ... word meanings Naming objects Logopenic variant primary progressive aphasia Symptoms include: Having difficulty retrieving words Frequently pausing ...

  16. Key performance indicators for the assessment of pediatric pharmacotherapeutic guidance.

    Science.gov (United States)

    Barrett, Jeffrey S; Patel, Dimple; Jayaraman, Bhuvana; Narayan, Mahesh; Zuppa, Athena

    2008-07-01

    Given the paucity of actual guidance provided for managing pediatric drug therapy, prescribing caregivers must be able to draw on the limited published information in pediatrics and/or guidance provided in adults with some account for expected pediatric response. Guidance for managing drug therapy in children is clearly desirable. Our objectives were to construct key performance indicators (KPIs) for pediatric pharmacotherapy guidance to identify drugs where pharmacotherapy guidance would be most beneficial. A pilot survey to assess variation in caregiver appreciation for pediatric dosing guidance has also been constructed to provide a complementary subjective assessment. Three KPI categories, drug utilization (based on hospital admission and billing data collected from 2001 through 2006), medical need, and guidance outcome value along with a KPI composite score have been proposed. Low scores are favored with respect to prioritization for pharmacotherapy guidance. The pilot survey consisted of 15 questions to assess 1) physician knowledge regarding dosing guidance, 2) attitudes toward dose modification and patient individualization, 3) the accessibility, ease of use and appropriateness of existing data stores, and 4) frequency of dosing modification, consultation of dosing compendiums and estimate of success rate in dosing guidance. Pilot results suggest that dosing guidance is generally viewed as important and that the existing resources are insufficient to guide recommendations for all drugs. While the majority of respondents check more than one resource less than 25% of the time, at least 25% of the respondents check more than one resource 25-50% of the time. The majority viewed the relevance of dosing guidance very important to the management of drug therapy. The questionnaire is being extended to the primary care centers, the Kids First Network and specialty care centers. Results will guide the development of decision support systems (DSS) that provide patient

  17. Stem cell therapy: MRI guidance and monitoring.

    Science.gov (United States)

    Kraitchman, Dara L; Gilson, Wesley D; Lorenz, Christine H

    2008-02-01

    With the recent advances in magnetic resonance (MR) labeling of cellular therapeutics, it is natural that interventional MRI techniques for targeting would be developed. This review provides an overview of the current methods of stem cell labeling and the challenges that are created with respect to interventional MRI administration. In particular, stem cell therapies will require specialized, MR-compatible devices as well as integration of graphical user interfaces with pulse sequences designed for interactive, real-time delivery in many organs. Specific applications that are being developed will be reviewed as well as strategies for future translation to the clinical realm. (Copyright) 2008 Wiley-Liss, Inc.

  18. The progressive tax

    OpenAIRE

    Estrada, Fernando

    2010-01-01

    This article describes the argumentative structure of Hayek on the relationship between power to tax and the progressive tax. It is observed throughout its work giving special attention to two works: The Constitution of Liberty (1959) and Law, Legislation and Liberty, vol3; The Political Order of Free People, 1979) Hayek describes one of the arguments most complete information bout SFP progressive tax systems (progressive tax). According to the author the history of the tax progressive system...

  19. A Three-Dimensional Cooperative Guidance Law of Multimissile System

    Directory of Open Access Journals (Sweden)

    Xing Wei

    2015-01-01

    Full Text Available In order to conduct saturation attacks on a static target, the cooperative guidance problem of multimissile system is researched. A three-dimensional guidance model is built using vector calculation and the classic proportional navigation guidance (PNG law is extended to three dimensions. Based on this guidance law, a distributed cooperative guidance strategy is proposed and a consensus protocol is designed to coordinate the time-to-go commands of all missiles. Then an expert system, which contains two extreme learning machines (ELM, is developed to regulate the local proportional coefficient of each missile according to the command. All missiles can arrive at the target simultaneously under the assumption that the multimissile network is connected. A simulation scenario is given to demonstrate the validity of the proposed method.

  20. HOLISTIC VISION: INTEGRATIVE APPROACH IN GUIDANCE AND COUNSELING SERVICES

    Directory of Open Access Journals (Sweden)

    Ade Hidayat

    2016-06-01

    Full Text Available Abstract: The philosophical issues in Guidance and Counseling especially in epistemological discourse have made paradigmatic friction that pointed by some issues from therapeutic-clinical to comprehensive way with preventive development prespective approach. It was also caused by the wider friction where quantum physic has remove classic Newtonian one, then the influence has generally removed another disciplines, where Guidance and Counseling in one of them. Through the comprehensive paradigm, Guidance dan Counseling need to take prepare the expert in order to capable to develop integrated and comprehensive thinking awareness. It means the Guidance and Counseling holistic vision is urged. Through the holistic vision, all of the competency of student is noticed integrally, such as intellectual, emotional, social, physical, artistic, creativity, ecological awareness, and spiritual competencies.Keywords: Ecoliteracy, Holictic Vision, Guidance and Counseling of Comprehensive.

  1. The vision guidance and image processing of AGV

    Science.gov (United States)

    Feng, Tongqing; Jiao, Bin

    2017-08-01

    Firstly, the principle of AGV vision guidance is introduced and the deviation and deflection angle are measured by image coordinate system. The visual guidance image processing platform is introduced. In view of the fact that the AGV guidance image contains more noise, the image has already been smoothed by a statistical sorting. By using AGV sampling way to obtain image guidance, because the image has the best and different threshold segmentation points. In view of this situation, the method of two-dimensional maximum entropy image segmentation is used to solve the problem. We extract the foreground image in the target band by calculating the contour area method and obtain the centre line with the least square fitting algorithm. With the help of image and physical coordinates, we can obtain the guidance information.

  2. Towards 4D intervention guidance using compressed sensing

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, Jan; Bartling, Soenke [Deutsches Krebsforschungszentrum DKFZ, Heidelberg (Germany); Brehm, Marcus; Kachelriess, Marc [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. of Medical Physics (IMP)

    2011-07-01

    Interventional radiology is nowadays usually guided with projection radiography using mono- or biplane systems. Due to the projective nature of this guidance imaging certain intraprocedural situations remain unclear. Although helpful, the use of 3D CT is limited due to radiation dose. Using advanced reconstruction techniques incorporating prior knowledge, one could overcome these limitations without exceeding dose limitations. Intervention guidance is especially appealing to those algorithms, because certain constrains apply to useful images in intervention guidance that vary relevantly from other CT applications. These are: key relevance of high contrast structures, sparse temporal updates and little relevance of absolute CT values. In this paper the principal usability of reconstruction algorithms for intervention guidance is tested. Compressed sensing algorithms PICCS and ASD-POCS are compared to the McKinnon-Bates and Feldkamp-Davis-Kress algorithm. Animal experiments as well as simulations are performed. An outlook towards 4D intervention guidance is provided. (orig.)

  3. European Universities' Guidance on Research Integrity and Misconduct.

    Science.gov (United States)

    Aubert Bonn, Noémie; Godecharle, Simon; Dierickx, Kris

    2017-02-01

    Research integrity is imperative to good science. Nonetheless, many countries and institutions develop their own integrity guidance, thereby risking incompatibilities with guidance of collaborating institutions. We retrieved guidance for academic integrity and misconduct of 18 universities from 10 European countries and investigated accessibility, general content, principles endorsed, and definitions of misconduct. Accessibility and content differ substantially between institutions. There are general trends of common principles of integrity and definitions of misconduct, yet differences remain. Parallel with previous research, we distinguish different approaches in integrity guidance; one emphasizes broad values of integrity, and the other details negative behaviors of misconduct. We propose that a balance between both approaches is necessary to preserve trust, meaning, and realism of guidance on research integrity.

  4. Eddy-current effect on resonant magnetoelectric coupling in magnetostrictive-piezoelectric laminated composites

    Science.gov (United States)

    Liu, Guoxi; Zhang, Chunli; Chen, Weiqiu; Dong, Shuxiang

    2013-07-01

    An analytical model of resonant magnetoelectric (ME) coupling in magnetostrictive (MS)-piezoelectric (PE) laminated composites in consideration of eddy-current effect in MS layer using equivalent circuit method is presented. Numerical calculations show that: (1) the eddy-current has a strong effect on ME coupling in MS-PE laminated composites at resonant frequency; and (2) the resonant ME coupling is then significantly dependent on the sizes of ME laminated composites, which were neglected in most previous theoretical analyses. The achieved results provide a theoretical guidance for the practice engineering design, manufacture, and application of ME laminated composites and devices.

  5. Transition metal nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Pregosin, P.S.

    1991-01-01

    Transition metal NMR spectroscopy has progressed enormously in recent years. New methods, and specifically solid-state methods and new pulse sequences, have allowed access to data from nuclei with relatively low receptivities with the result that chemists have begun to consider old and new problems, previously unapproachable. Moreover, theory, computational science in particular, now permits the calculation of not just 13 C, 15 N and other light nuclei chemical shifts, but heavy main-group element and transition metals as well. These two points, combined with increasing access to high field pulsed spectrometer has produced a wealth of new data on the NMR transition metals. A new series of articles concerned with measuring, understanding and using the nuclear magnetic resonance spectra of the metals of Group 3-12 is presented. (author)

  6. Trapped atoms along nanophotonic resonators

    Science.gov (United States)

    Fields, Brian; Kim, May; Chang, Tzu-Han; Hung, Chen-Lung

    2017-04-01

    Many-body systems subject to long-range interactions have remained a very challenging topic experimentally. Ultracold atoms trapped in extreme proximity to the surface of nanophotonic structures provides a dynamic system combining the strong atom-atom interactions mediated by guided mode photons with the exquisite control implemented with trapped atom systems. The hybrid system promises pair-wise tunability of long-range interactions between atomic pseudo spins, allowing studies of quantum magnetism extending far beyond nearest neighbor interactions. In this talk, we will discuss our current status developing high quality nanophotonic ring resonators, engineered on CMOS compatible optical chips with integrated nanostructures that, in combination with a side illuminating beam, can realize stable atom traps approximately 100nm above the surface. We will report on our progress towards loading arrays of cold atoms near the surface of these structures and studying atom-atom interaction mediated by photons with high cooperativity.

  7. A genomic pathway approach to a complex disease: axon guidance and Parkinson disease.

    Directory of Open Access Journals (Sweden)

    Timothy G Lesnick

    2007-06-01

    Full Text Available While major inroads have been made in identifying the genetic causes of rare Mendelian disorders, little progress has been made in the discovery of common gene variations that predispose to complex diseases. The single gene variants that have been shown to associate reproducibly with complex diseases typically have small effect sizes or attributable risks. However, the joint actions of common gene variants within pathways may play a major role in predisposing to complex diseases (the paradigm of complex genetics. The goal of this study was to determine whether polymorphism in a candidate pathway (axon guidance predisposed to a complex disease (Parkinson disease [PD]. We mined a whole-genome association dataset and identified single nucleotide polymorphisms (SNPs that were within axon-guidance pathway genes. We then constructed models of axon-guidance pathway SNPs that predicted three outcomes: PD susceptibility (odds ratio = 90.8, p = 4.64 x 10(-38, survival free of PD (hazards ratio = 19.0, p = 5.43 x 10(-48, and PD age at onset (R(2 = 0.68, p = 1.68 x 10(-51. By contrast, models constructed from thousands of random selections of genomic SNPs predicted the three PD outcomes poorly. Mining of a second whole-genome association dataset and mining of an expression profiling dataset also supported a role for many axon-guidance pathway genes in PD. These findings could have important implications regarding the pathogenesis of PD. This genomic pathway approach may also offer insights into other complex diseases such as Alzheimer disease, diabetes mellitus, nicotine and alcohol dependence, and several cancers.

  8. Controlling Parametric Resonance

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Pettersen, Kristin Ytterstad

    2012-01-01

    the authors review the conditions for the onset of parametric resonance, and propose a nonlinear control strategy in order to both induce the resonant oscillations and to stabilize the unstable motion. Lagrange’s theory is used to derive the dynamics of the system and input–output feedback linearization...

  9. Electron Paramagnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 11. Electron Paramagnetic Resonance Spectroscopy: Biological Applications. B G Hegde. General Article Volume 20 Issue 11 November 2015 pp 1017-1032. Fulltext. Click here to view fulltext PDF. Permanent link:

  10. Electromagnetic resonance waves

    International Nuclear Information System (INIS)

    Villaba, J.M.; Manjon, F.J.; Guirao, A.; Andres, M.V.

    1994-01-01

    We describe in this paper a set of experiments designed to make qualitative and quantitative measurements on electromagnetic resonances of several simple systems. The experiments are designed for the undergraduate laboratory of Electricity and Magnetism in Physics. These experiments can help the students understanding the concept of resonance, which appears in different fields of Physics. (Author) 8 refs

  11. Laser magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Ferrari, C.A.

    1985-01-01

    The technique of laser resonance magnetic resonance allows one to study the high-resolution spectroscopy of transient paramagnetic species, viz, atoms, radicals, and molecular ions. This article is a brief exposition of the method, describing the principles, instrumentation and applicability of the IR and FIR-LMR and shows results of HF + . (Author) [pt

  12. Resonance and Fractal Geometry

    NARCIS (Netherlands)

    Broer, Henk W.

    The phenomenon of resonance will be dealt with from the viewpoint of dynamical systems depending on parameters and their bifurcations. Resonance phenomena are associated to open subsets in the parameter space, while their complement corresponds to quasi-periodicity and chaos. The latter phenomena

  13. Nuclear Magnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Nuclear Magnetic Resonance Spectroscopy. Susanta Das. General Article Volume 9 Issue 1 January 2004 pp 34-49. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0034-0049. Keywords.

  14. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  15. Robust approximate optimal guidance strategies for aeroassisted orbital transfer missions

    Science.gov (United States)

    Ilgen, Marc R.

    This thesis presents the application of game theoretic and regular perturbation methods to the problem of determining robust approximate optimal guidance laws for aeroassisted orbital transfer missions with atmospheric density and navigated state uncertainties. The optimal guidance problem is reformulated as a differential game problem with the guidance law designer and Nature as opposing players. The resulting equations comprise the necessary conditions for the optimal closed loop guidance strategy in the presence of worst case parameter variations. While these equations are nonlinear and cannot be solved analytically, the presence of a small parameter in the equations of motion allows the method of regular perturbations to be used to solve the equations approximately. This thesis is divided into five parts. The first part introduces the class of problems to be considered and presents results of previous research. The second part then presents explicit semianalytical guidance law techniques for the aerodynamically dominated region of flight. These guidance techniques are applied to unconstrained and control constrained aeroassisted plane change missions and Mars aerocapture missions, all subject to significant atmospheric density variations. The third part presents a guidance technique for aeroassisted orbital transfer problems in the gravitationally dominated region of flight. Regular perturbations are used to design an implicit guidance technique similar to the second variation technique but that removes the need for numerically computing an optimal trajectory prior to flight. This methodology is then applied to a set of aeroassisted inclination change missions. In the fourth part, the explicit regular perturbation solution technique is extended to include the class of guidance laws with partial state information. This methodology is then applied to an aeroassisted plane change mission using inertial measurements and subject to uncertainties in the initial value

  16. 75 FR 73107 - Guidance for Industry and Food and Drug Administration Staff; Blood Lancet Labeling; Availability

    Science.gov (United States)

    2010-11-29

    ...] Guidance for Industry and Food and Drug Administration Staff; Blood Lancet Labeling; Availability AGENCY... announcing the availability of the guidance entitled ``Guidance for Industry and Food and Drug Administration... single copies of the guidance document entitled ``Guidance for Industry and Food and Drug Administration...

  17. 75 FR 70254 - PSD and Title V Permitting Guidance for Greenhouse Gases

    Science.gov (United States)

    2010-11-17

    ... Guidance for Greenhouse Gases AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability..., ``PSD and Title V Permitting Guidance for Greenhouse Gases'' on its significant guidance Internet Web... guidance titled, ``PSD and Title V Permitting Guidance for Greenhouse Gases.'' This document has been...

  18. 78 FR 52203 - Guidance for Industry on Compliance With Regulations Restricting the Sale and Distribution of...

    Science.gov (United States)

    2013-08-22

    ... guidance document consistent with FDA's good guidance practices regulation (21 CFR 10.115). The guidance...] Guidance for Industry on Compliance With Regulations Restricting the Sale and Distribution of Cigarettes... Distribution of Cigarettes and Smokeless Tobacco to Protect Children and Adolescents.'' This guidance is...

  19. Fundamentals of nanomechanical resonators

    CERN Document Server

    Schmid, Silvan; Roukes, Michael Lee

    2016-01-01

    This authoritative book introduces and summarizes the latest models and skills required to design and optimize nanomechanical resonators, taking a top-down approach that uses macroscopic formulas to model the devices. The authors cover the electrical and mechanical aspects of nano electromechanical system (NEMS) devices. The introduced mechanical models are also key to the understanding and optimization of nanomechanical resonators used e.g. in optomechanics. Five comprehensive chapters address: The eigenmodes derived for the most common continuum mechanical structures used as nanomechanical resonators; The main sources of energy loss in nanomechanical resonators; The responsiveness of micro and nanomechanical resonators to mass, forces, and temperature; The most common underlying physical transduction mechanisms; The measurement basics, including amplitude and frequency noise. The applied approach found in this book is appropriate for engineering students and researchers working with micro and nanomechanical...

  20. Resonant snubber inverter

    Science.gov (United States)

    Lai, Jih-Sheng; Young, Sr., Robert W.; Chen, Daoshen; Scudiere, Matthew B.; Ott, Jr., George W.; White, Clifford P.; McKeever, John W.

    1997-01-01

    A resonant, snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the main inverter switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.

  1. 76 FR 20992 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-04-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0189] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Low Level Laser System for Aesthetic Use; Availability AGENCY: Food and Drug Administration, HHS...

  2. 75 FR 70271 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2010-11-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0515] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document...: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is...

  3. 75 FR 68364 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2008-D-0275] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Full-Field Digital Mammography System; Availability AGENCY: Food and Drug Administration, HHS. [[Page...

  4. 76 FR 16425 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0028] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Ovarian Adnexal Mass Assessment Score Test System; Availability AGENCY: Food and Drug Administration, HHS...

  5. 76 FR 6622 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0645] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Contact Cooling System for Aesthetic Use; Availability AGENCY: Food and Drug Administration, HHS. ACTION...

  6. 76 FR 22906 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-04-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2006-D-0094] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Topical Oxygen Chamber for Extremities; Availability AGENCY: Food and Drug Administration, HHS. ACTION...

  7. 76 FR 43332 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-07-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0500] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Focused Ultrasound Stimulator System for Aesthetic Use; Availability AGENCY: Food and Drug Administration...

  8. 76 FR 43690 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-07-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2007-D-0149] (Formerly 2007D-0309) Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Electrocardiograph Electrodes; Availability AGENCY: Food and Drug...

  9. 77 FR 14403 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-D-0167] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document: Norovirus Serological Reagents; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice...

  10. 76 FR 48870 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-08-09

    ... selection inclusion and exclusion criteria section. The revisions define and differentiate the required... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0428] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document...

  11. An Investigation of the Guidance Counselling Needs of Adults with Dyslexia in the Adult Educational Guidance Initiative (AEGI)

    Science.gov (United States)

    Elftorp, Petra; Hearne, Lucy

    2014-01-01

    The experiences of adult learners with dyslexia is an under-researched area in Ireland at present. This article will discuss the findings from phase one of a mixed methods research study, which is investigating the guidance counselling needs of clients with dyslexia within the Adult Education Guidance Initiative (AEGI). The research is underpinned…

  12. 76 FR 44594 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Science.gov (United States)

    2011-07-26

    ... Dockets Management (see ADDRESSES) either electronic or written comments regarding this document. It is... Stimulation Systems.'' This guidance document describes a means by which a repetitive transcranial magnetic... guidance document is being immediately implemented as the special control for rTMS systems, but it remains...

  13. Guidance manual for conducting technology demonstration activities

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, Robert L.; Morris, Michael I.; Singh, Suman P.N.

    1991-12-01

    This demonstration guidance manual has been prepared to assist Martin Marietta Energy Systems, Inc. (Energy Systems), staff in conducting demonstrations. It is prepared in checklist style to facilitate its use and assumes that Energy Systems personnel have project management responsibility. In addition to a detailed step-by-step listing of procedural considerations, a general checklist, logic flow diagram, and several examples of necessary plans are included to assist the user in developing an understanding of the many complex activities required to manage technology demonstrations. Demonstrations are pilot-scale applications of often innovative technologies to determine the commercial viability of the technologies to perform their designed function. Demonstrations are generally conducted on well-defined problems for which existing technologies or processes are less than satisfactory in terms of effectiveness, cost, and/or regulatory compliance. Critically important issues in demonstration management include, but are not limited to, such factors as communications with line and matrix management and with the US Department of Energy (DOE) and Energy Systems staff responsible for management oversight, budgetary and schedule requirements, regulatory compliance, and safety.

  14. CANDU severe accident management guidance update

    International Nuclear Information System (INIS)

    Jones, L.; Popov, N.; Gilbert, L.; Weed, J.

    2014-01-01

    The CANDU Owners Group (COG) developed a set of generic and initial station-specific Severe Accident Management Guidance (SAMG) documents to mitigate the consequences to the public in the event of a severe accident. The generic portion of the COG SAMG was completed in 2006; the overall project including the station-specific phase was completed in April 2007. Over the years, the CANDU industry and utilities have continuously increased the knowledge base for SAMG and have incorporated various engineered features based on the knowledge obtained. As a result of the event that occurred at the Fukushima Daiiachi nuclear power plant (NPP) in Japan, the Canadian Nuclear Safety Commission (CNSC) established the CNSC Fukushima Task Force. The results of the task force were documented in INFO-0828, CNSC Staff Action Plan on the CNSC Fukushima Task Force Recommendations. Among the recommendation documented in INFO-828 were Fukushima Action Items (FAIs) directed towards the CANDU utilities in Canada; a portion of which are related to SAMG documentation updates and directed at enhancing SAM response. A COG joint project was established to support the closure of the CNSC FAIs and to revise the current CANDU documentation accordingly. This paper provides a high level summary of the COG project scope and results. It also demonstrates that the CANDU SAMG programs in Canada provide robust protection and mitigation of severe accidents. (author)

  15. CANDU severe accident management guidance update

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L., E-mail: lisa.m.jones@opg.com [Ontario Power Generation, Pickering, ON (Canada); Popov, N., E-mail: nik.popov@rogers.com [Candu Owners Group, Toronto, ON (Canada); Gilbert, L., E-mail: lovell.gilbert@brucepower.com [Bruce Power, Tiverton, ON (Canada); Weed, J., E-mail: jeff.weed@candu.gov [Candu Owners Group, Toronto, ON (Canada)

    2014-07-01

    The CANDU Owners Group (COG) developed a set of generic and initial station-specific Severe Accident Management Guidance (SAMG) documents to mitigate the consequences to the public in the event of a severe accident. The generic portion of the COG SAMG was completed in 2006; the overall project including the station-specific phase was completed in April 2007. Over the years, the CANDU industry and utilities have continuously increased the knowledge base for SAMG and have incorporated various engineered features based on the knowledge obtained. As a result of the event that occurred at the Fukushima Daiiachi nuclear power plant (NPP) in Japan, the Canadian Nuclear Safety Commission (CNSC) established the CNSC Fukushima Task Force. The results of the task force were documented in INFO-0828, CNSC Staff Action Plan on the CNSC Fukushima Task Force Recommendations. Among the recommendation documented in INFO-828 were Fukushima Action Items (FAIs) directed towards the CANDU utilities in Canada; a portion of which are related to SAMG documentation updates and directed at enhancing SAM response. A COG joint project was established to support the closure of the CNSC FAIs and to revise the current CANDU documentation accordingly. This paper provides a high level summary of the COG project scope and results. It also demonstrates that the CANDU SAMG programs in Canada provide robust protection and mitigation of severe accidents. (author)

  16. New IAEA guidance on safety culture

    International Nuclear Information System (INIS)

    Haage, Monica; )

    2012-01-01

    Monica Haage described a project for Kozloduy Nuclear Power Plant in Bulgaria which was also funded by the Norwegian government. This project included the development of guidance documents and training on self-assessment and continuous improvement of safety culture. A draft IAEA safety culture survey was also developed as part of this project in collaboration with St Mary's University, Canada. This project was conducted in parallel with an IAEA project to develop new safety reports on safety culture self-assessment and continuous improvement. A safety report on safety culture during the pre-operational phases of NPPs has also been drafted. The IAEA approach to safety culture assessment was outlined and core principles of the approach were discussed. These include the use of several assessment methods (survey, interview, observation, focus groups, document review), and two distinct levels of analysis. The first is a descriptive analysis of the observed cultural characteristics from each assessment method and overarching themes. This is followed by a 'normative' analysis comparing what has been observed with the desirable characteristics of a strong, positive, safety culture, as defined by the IAEA safety culture framework. The application of this approach during recent Operational Safety Assessment Review Team (OSART) missions was described along with key learning points

  17. Image-guidance for surgical procedures

    International Nuclear Information System (INIS)

    Peters, Terry M

    2006-01-01

    Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other and to the patient. The other important component of IGS is the ability to track instruments in real time during the procedure and to display them as part of a realistic model of the operative volume. Stereoscopic, virtual- and augmented-reality techniques have been implemented to enhance the visualization and guidance process. For the most part, IGS relies on the assumption that the pre-operatively acquired images used to guide the surgery accurately represent the morphology of the tissue during the procedure. This assumption may not necessarily be valid, and so intra-operative real-time imaging using interventional MRI, ultrasound, video and electrophysiological recordings are often employed to ameliorate this situation. Although IGS is now in extensive routine clinical use in neurosurgery and is gaining ground in other surgical disciplines, there remain many drawbacks that must be overcome before it can be employed in more general minimally-invasive procedures. This review overviews the roots of IGS in neurosurgery, provides examples of its use outside the brain, discusses the infrastructure required for successful implementation of IGS approaches and outlines the challenges that must be overcome for IGS to advance further. (topical review)

  18. Guidance manual for conducting technology demonstration activities

    International Nuclear Information System (INIS)

    Jolley, R.L.; Morris, M.I.; Singh, S.P.N.

    1991-12-01

    This demonstration guidance manual has been prepared to assist Martin Marietta Energy Systems, Inc. (Energy Systems), staff in conducting demonstrations. It is prepared in checklist style to facilitate its use and assumes that Energy Systems personnel have project management responsibility. In addition to a detailed step-by-step listing of procedural considerations, a general checklist, logic flow diagram, and several examples of necessary plans are included to assist the user in developing an understanding of the many complex activities required to manage technology demonstrations. Demonstrations are pilot-scale applications of often innovative technologies to determine the commercial viability of the technologies to perform their designed function. Demonstrations are generally conducted on well-defined problems for which existing technologies or processes are less than satisfactory in terms of effectiveness, cost, and/or regulatory compliance. Critically important issues in demonstration management include, but are not limited to, such factors as communications with line and matrix management and with the US Department of Energy (DOE) and Energy Systems staff responsible for management oversight, budgetary and schedule requirements, regulatory compliance, and safety

  19. Minisatellite Attitude Guidance Using Reaction Wheels

    Directory of Open Access Journals (Sweden)

    Ion STROE

    2015-06-01

    Full Text Available In a previous paper [2], the active torques needed for the minisatellite attitude guidance from one fixed attitude posture to another fixed attitude posture were determined using an inverse dynamics method. But when considering reaction/momentum wheels, instead of this active torques computation, the purpose is to compute the angular velocities of the three reaction wheels which ensure the minisatellite to rotate from the initial to the final attitude. This paper presents this computation of reaction wheels angular velocities using a similar inverse dynamics method based on inverting Euler’s equations of motion for a rigid body with one fixed point, written in the framework of the x-y-z sequence of rotations parameterization. For the particular case A=B not equal C of an axisymmetric minisatellite, the two computations are compared: the active torques computation versus the computation of reaction wheels angular velocities ̇x , ̇y and ̇z. An interesting observation comes out from this numerical study: if the three reaction wheels are identical (with Iw the moment of inertia of one reaction wheel with respect to its central axis, then the evolutions in time of the products between Iw and the derivatives of the reaction wheels angular velocities, i.e. ̇ , ̇ and ̇ remain the same and do not depend on the moment of inertia Iw.

  20. Wheelset curving guidance using H∞ control

    Science.gov (United States)

    Qazizadeh, Alireza; Stichel, Sebastian; Feyzmahdavian, Hamid Reza

    2018-03-01

    This study shows how to design an active suspension system for guidance of a rail vehicle wheelset in curve. The main focus of the study is on designing the controller and afterwards studying its effect on the wheel wear behaviour. The controller is designed based on the closed-loop transfer function shaping method and ? control strategy. The study discusses designing of the controller for both nominal and uncertain plants and considers both stability and performance. The designed controllers in Simulink are then applied to the vehicle model in Simpack to study the wheel wear behaviour in curve. The vehicle type selected for this study is a two-axle rail vehicle. This is because this type of vehicle is known to have very poor curving performance and high wheel wear. On the other hand, the relative simpler structure of this type of vehicle compared to bogie vehicles make it a more economic choice. Hence, equipping this type of vehicle with the active wheelset steering is believed to show high enough benefit to cost ratio to remain attractive to rail vehicle manufacturers and operators.

  1. Bibliography - Existing Guidance for External Hazard Modelling

    International Nuclear Information System (INIS)

    Decker, Kurt

    2015-01-01

    The bibliography of deliverable D21.1 includes existing international and national guidance documents and standards on external hazard assessment together with a selection of recent scientific papers, which are regarded to provide useful information on the state of the art of external event modelling. The literature database is subdivided into International Standards, National Standards, and Science Papers. The deliverable is treated as a 'living document' which is regularly updated as necessary during the lifetime of ASAMPSA-E. The current content of the database is about 140 papers. Most of the articles are available as full-text versions in PDF format. The deliverable is available as an EndNote X4 database and as text files. The database includes the following information: Reference, Key words, Abstract (if available), PDF file of the original paper (if available), Notes (comments by the ASAMPSA-E consortium if available) The database is stored at the ASAMPSA-E FTP server hosted by IRSN. PDF files of original papers are accessible through the EndNote software

  2. Supplementary guidance for the investigation and risk-assessment of potentially contaminated sediments

    Energy Technology Data Exchange (ETDEWEB)

    Baker, K.; Spadaro, P.; Starr, J.; Thomas, J. [Arcadis, Arnhem (Netherlands); Hildenbrand, B. [Energy Institute, London (United Kingdom); Smith, J.W.N.; Dunk, M.; Grosjean, T.; De Ibarra, M.; Medve, A.; Den Haan, K.

    2013-11-15

    This report provides guidance on the investigation and assessment of potentially contaminated sediments, focusing on the inland, estuarine and coastal environments. It is designed as a complementary, technical companion document to Energy Institute and CONCAWE (2013) report 'Guidance on characterising, assessing and managing risks associated with potentially contaminated sediments' (Report E1001). It highlights a number of significant challenges associated with assessing the aquatic and water bottom environment, which means that a sediment assessment should not be undertaken lightly. Where a decision is taken to undertake a site assessment, this report promotes the use of an iterative process of Conceptual Site Model (CSM) development, data collection, data evaluation and a continuous CSM refinement, taking into account the results obtained. Risk-based assessment is described throughout the report, entailing four tiers of assessment, which progress from a qualitative assessment (Tier 0) through to a detailed cause-attribution assessment (Tier 3), in which the decrease in uncertainty in the assessment process is balanced against the increased costs and timescales with progress to a higher tier assessment. The application of this evidence-driven risk-based approach to sediment site management, including remedial control measures, should help to overcome at least some of the challenges associated with contaminants in sediment sites in Europe, and promote a sustainable approach to sediment management on a case-by-case basis.

  3. Visual search guidance is best after a short delay.

    Science.gov (United States)

    Schmidt, Joseph; Zelinsky, Gregory J

    2011-03-25

    Search displays are typically presented immediately after a target cue, but in the real-world, delays often exist between target designation and search. Experiments 1 and 2 asked how search guidance changes with delay. Targets were cued using a picture or text label, each for 3000ms, followed by a delay up to 9000ms before the search display. Search stimuli were realistic objects, and guidance was quantified using multiple eye movement measures. Text-based cues showed a non-significant trend towards greater guidance following any delay relative to a no-delay condition. However, guidance from a pictorial cue increased sharply 300-600ms after preview offset. Experiment 3 replicated this guidance enhancement using shorter preview durations while equating the time from cue onset to search onset, demonstrating that the guidance benefit is linked to preview offset rather than a more complete encoding of the target. Experiment 4 showed that enhanced guidance persists even with a mask flashed at preview offset, suggesting an explanation other than visual priming. We interpret our findings as evidence for the rapid consolidation of target information into a guiding representation, which attains its maximum effectiveness shortly after preview offset. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  5. Multiple photon resonances

    International Nuclear Information System (INIS)

    Elliott, C.J.; Feldman, B.J.

    1979-02-01

    A detailed theoretical analysis is presented of the interaction of intense near-resonant monochromatic radiation with an N-level anharmonic oscillator. In particular, the phenomenon of multiple photon resonance, the process by which an N-level system resonantly absorbs two or more photons simultaneously, is investigated. Starting from the Schroedinger equation, diagrammatic techniques are developed that allow the resonant process to be analyzed quantitatively, in analogy with well-known two-level coherent phenomena. In addition, multiple photon Stark shifts of the resonances, shifts absent in two-level theory, are obtained from the diagrams. Insights into the nature of multiple photon resonances are gained by comparing the quantum mechanical system with classical coupled pendulums whose equations of motion possess identical eigenvalues and eigenvectors. In certain limiting cases, including that of the resonantly excited N-level harmonic oscillator and that of the equally spaced N-level system with equal matrix elements, analytic results are derived. The influence of population relaxation and phase-disrupting collisions on the multiple photon process are also analyzed, the latter by extension of the diagrammatic technique to the density matrix equations of motion. 11 figures

  6. Properties of spiral resonators

    International Nuclear Information System (INIS)

    Haeuser, J.

    1989-10-01

    The present thesis deals with the calculation and the study of the application possibilities of single and double spiral resonators. The main aim was the development and the construction of reliable and effective high-power spiral resonators for the UNILAC of the GSI in Darmstadt and the H - -injector for the storage ring HERA of DESY in Hamburg. After the presentation of the construction and the properties of spiral resonators and their description by oscillating-circuit models the theoretical foundations of the bunching are presented and some examples of a rebuncher and debuncher and their influence on the longitudinal particle dynamics are shown. After the description of the characteristic accelerator quantities by means of an oscillating-circuit model and the theory of an inhomogeneous λ/4 line it is shown, how the resonance frequency and the efficiency of single and double spiral resonators can be calculated from the geometrical quantities of the structure. In the following the dependence of the maximal reachable resonator voltage in dependence on the gap width and the surface of the drift tubes is studied. Furthermore the high-power resonators are presented, which were built for the different applications for the GSI in Darmstadt, DESY in Hamburg, and for the FOM Institute in Amsterdam. (orig./HSI) [de

  7. Progress report 1989-90

    International Nuclear Information System (INIS)

    1991-01-01

    Since the beginning of 1980, the research activities of our division have been centred around the use of lasers. Research on emission spectroscopy and term analysis is being pursued with emphasis on the analysis of the spectra of multiply ionized inert gases. In the basic atomic laser spectroscopy group the experimental activities employing CW high-resolution techniques and time-resolved methods are well integrated with a theoretical atomic physics programme. A precision method for lifetime measurements using a mode-locked dye laser in conjunction with photon counting techniques has been further refined. Pulsed level-crossing, optical-double-resonance and quantum-beat spectroscopy have been used extensively to attain new accurate data. Studies of terawatt laser generation techniques have been made in preparation for the establishment of such techniques at the Lund Laser Center. For several years, a major project concerned with combustion diagnostics using lasers has been pursued in Lund. Many aspects of flame kinetics, NO x and soot formation, turbulence and spark ignition are being studied using laser-induced fluorescence. Raman and CARS spectroscopy. Theoretical work on kinetics and spark ignition supplements the extensive programme. Methods for combustion diagnostics based on multicolour imaging, degenerate four-wave mixing and diode-laser frequencymodulation spectroscopy are being developed. Environmental remote sensing using optical techniques is another applied spectroscopy project. Our mobile lidar system has been extensively used for range-resolved mapping of atomic mercury. During the last two years our activities in the medical field have increased. A research programme on cancer tumour detection and treatment using lasers is being pursued jointly with the Lund University Hospital. Work on spectroscopic diagnostics of atherosclerotic plaque is also being actively pursued, aiming at spectroscopic guidance in fibreoptic plaque ablation using excimer laser

  8. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  9. Media in guidance and counseling services: a tool and innovation for school counselor

    Directory of Open Access Journals (Sweden)

    Said Alhadi

    2016-12-01

    Full Text Available Guidance and counseling services is an element of education that aims to support the achievement of the objectives of education. Guidance and counseling can prevent students experience problems and may even alleviate student of his problems. One of the efforts that need to be done to improve the effectiveness of guidance and counseling services is the development of media guidance and counseling. Media guidance and counseling can make different colors of guidance and counseling services so that the interests of students increase when following the guidance and counseling services. Used media must be relevant with the objectives/ competency of the guidance and counseling and relevant with material guidance and counseling services. Media in guidance and counseling services plays an important role in the implementation of guidance and counseling so that student can better understand, understand, and internalize the material guidance and counseling services to the student.

  10. Draft Updates to the Planning for Natural Disaster Debris Guidance and to Related Documents

    Science.gov (United States)

    EPA is requesting comment on the draft update of the Planning for Natural Disaster Debris Guidance, along with two other documents. This Guidance is an update of the Planning for Natural Disaster Debris guidance that EPA published in March 2008.

  11. 75 FR 36471 - Seventh Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-06-25

    ... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The... Committee 220: Automatic Flight Guidance and [[Page 36472

  12. 78 FR 72899 - Draft Guidance for Industry on Registration for Human Drug Compounding Outsourcing Facilities...

    Science.gov (United States)

    2013-12-04

    ... information technology. Under the draft guidance, outsourcing facilities that elect to register should submit... guidance provides information on how an outsourcing facility should submit facility registration...] Draft Guidance for Industry on Registration for Human Drug Compounding Outsourcing Facilities Under...

  13. Quality Assurance Guidance for the Collection of Meteorological Data Using Passive Radiometers

    Science.gov (United States)

    This document augments the February 2000 guidance entitled Meteorological Monitoring Guidance for Regulatory Modeling Applications and the March 2008 guidance entitled Quality Assurance Handbook for Air Pollution Measurement Systems Volume IV: Meteorological Measurements Version ...

  14. 76 FR 71577 - Guidance for Industry on Medication Guide Distribution Requirements and Inclusion of Medication...

    Science.gov (United States)

    2011-11-18

    ...] Guidance for Industry on Medication Guide Distribution Requirements and Inclusion of Medication Guides in... guidance for industry entitled ``Medication Guides-- Distribution Requirements and Inclusion in Risk... Requirements and Inclusion in Risk Evaluation and Mitigation Strategies (REMS).'' This guidance provides...

  15. 78 FR 66744 - Draft Guidance for Industry on Pulmonary Tuberculosis: Developing Drugs for Treatment; Availability

    Science.gov (United States)

    2013-11-06

    ...] Draft Guidance for Industry on Pulmonary Tuberculosis: Developing Drugs for Treatment; Availability...) is announcing the availability of a draft guidance for industry entitled ``Pulmonary Tuberculosis... of antimycobacterial drugs for the treatment of pulmonary tuberculosis. This guidance applies to the...

  16. 75 FR 63188 - Draft Guidance for Industry: Early Clinical Trials With Live Biotherapeutic Products: Chemistry...

    Science.gov (United States)

    2010-10-14

    ...] Draft Guidance for Industry: Early Clinical Trials With Live Biotherapeutic Products: Chemistry...: Chemistry, Manufacturing, and Control Information'' dated September 2010. The draft guidance provides... Products: Chemistry, Manufacturing, and Control Information'' dated September 2010. The draft guidance...

  17. Resonant power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2012-01-01

    This book is devoted to resonant energy conversion in power electronics. It is a practical, systematic guide to the analysis and design of various dc-dc resonant inverters, high-frequency rectifiers, and dc-dc resonant converters that are building blocks of many of today's high-frequency energy processors. Designed to function as both a superior senior-to-graduate level textbook for electrical engineering courses and a valuable professional reference for practicing engineers, it provides students and engineers with a solid grasp of existing high-frequency technology, while acquainting them wit

  18. Excitation of Nucleon Resonances

    International Nuclear Information System (INIS)

    Burkert, Volker D.

    2001-01-01

    I discuss developments in the area of nucleon resonance excitation, both necessary and feasible, that would put our understanding of nucleon structure in the regime of strong QCD on a qualitatively new level. They involve the collection of high quality data in various channels, a more rigorous approach in the search for ''missing'' resonances, an effort to compute some critical quantities in nucleon resonance excitations from first principles, i.e. QCD, and a proposal focused to obtain an understanding of a fundamental quantity in nucleon structure

  19. Dihadronic and dileptonic resonances

    International Nuclear Information System (INIS)

    Gareev, F.A.; Barabanov, M.Yu.; Kazacha, G.S.

    1997-01-01

    Simple phenomenological rules are suggested for calculation of dihadron and dilepton resonance masses. A general interpretation is given for different exotic resonances in nuclear physics: Darmstadt-effect, dibaryon, dipion and other resonances. Information about the inner structure of e ± , proton, neutron, pions and so on can be obtained from the usual reactions of the type e + + e - =>γγ, e ± +γ=>e ± γ, e ± μ ± , e ± N... at low, intermediate and high energies using existing experimental devices

  20. Multiquark resonant states

    International Nuclear Information System (INIS)

    Shahbazian, B.A.

    1982-01-01

    The invariant mass spectra of forty nine hadronic systems with hypercharge, strangeness and baryon number, varied in wide limits have been studied. Resonance peaks have been found in the invariant mass spectra of Y 2 and #betta#pπ 2495 MeV/c 2 resonant states. Three more candidates for anti qq 4 states were found #bettaπ# + π + : 1705, 2072, 2605 MeV/c 2 . The masses of all these candidates are in good agreement with Bag Model predictions. A hypercharge selection rule is suggested: ''The hypercharge of hadronic resonances in weak gravitational fields cannot exceed one Y <= 1

  1. Resonant halide perovskite nanoparticles

    Science.gov (United States)

    Tiguntseva, Ekaterina Y.; Ishteev, Arthur R.; Komissarenko, Filipp E.; Zuev, Dmitry A.; Ushakova, Elena V.; Milichko, Valentin A.; Nesterov-Mueller, Alexander; Makarov, Sergey V.; Zakhidov, Anvar A.

    2017-09-01

    The hybrid halide perovskites is a prospective material for fabrication of cost-effective optical devices. Unique perovskites properties are used for solar cells and different photonic applications. Recently, perovskite-based nanophotonics has emerged. Here, we consider perovskite like a high-refractive index dielectric material, which can be considered to be a basis for nanoparticles fabrication with Mie resonances. As a result, we fabricate and study resonant perovskite nanoparticles with different sizes. We reveal, that spherical nanoparticles show enhanced photoluminescence signal. The achieved results lay a cornerstone in the field of novel types of organic-inorganic nanophotonics devices with optical properties improved by Mie resonances.

  2. Writing with resonance

    DEFF Research Database (Denmark)

    Meier, Ninna; Wegener, Charlotte

    2017-01-01

    In this article, we explore what organization and management scholars can do to write with resonance and to facilitate an emotional, bodily, or in other ways sensory connection between the text and the reader. We propose that resonance can be relevant for organization and management scholars in two......, and thus bring forward the field of research in question. We propose that writing with resonance may be a way to further the impact of academic work by extending the modalities with which our readers can relate to and experience our work....

  3. Doubly resonant multiphoton ionization

    International Nuclear Information System (INIS)

    Crance, M.

    1978-01-01

    A particular case of doubly resonant multiphoton ionization is theoretically investigated. More precisely, two levels quasi-resonant with two successive harmonics of the field frequency are considered. The method used is based on the effective operator formalism first introduced for this problem by Armstrong, Beers and Feneuille. The main result is to show the possibility of observing large interference effects on the width of the resonances. Moreover this treatment allows us to make more precise the connection between effective operator formalism and standard perturbation theory

  4. Supporting Adolescents with Guidance and Employment (SAGE).

    Science.gov (United States)

    Ringwalt, C L; Graham, L A; Paschall, M J; Flewelling, R L; Browne, D C

    1996-01-01

    Supporting Adolescents with Guidance and Employment (SAGE) is a multifaceted, community-based violence-prevention program. Its target is African-American male adolescents in Durham, North Carolina. Public health professionals, county government officials, and local businessmen collaborated in its development and implementation. The program is based on the paradigm of risk and protective factors, in which various risk factors for youth violence are buffered by modifiable, protective psychosocial processes. SAGE includes an eight-month African-American Rites of Passage program (adult mentoring, African-American culture and history lessons, and manhood and conflict-resolution training), a six-week summer employment component, and a 12-week entrepreneurial experience. Of the 260 youth recruited, 88 were randomly assigned to receive all three program components, 85 were assigned to the summer employment and entrepreneurial components only, and 87 were assigned to a delayed program or control condition. We compared these three groups' psychosocial and behavioral outcomes using survey data and archival records. Program implementation data include attendance records; mentor-youth activity logs pre- and postprogram focus group discussions; and telephone interviews with parents, program staff, and participants. The mean age of the adolescents recruited into the program was 14. Half reported receiving free lunches at school; half were not living with a father; and one quarter reported that their mothers had not completed high school. During the previous year, many had engaged in various violence-related behaviors, including fighting (49%) and carrying a gun (22%). Youths in each program condition were similar with respect to key demographic and behavioral characteristics. The key components of the SAGE program represent increasingly popular but untested approaches. Preliminary results reveal that these youths are involved in violent behavior both as perpetrators and as

  5. Energy audit at Russian dairies. Energy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Draborg, S [Dansk Energi Analyse A/S, Vanloese (Denmark); Sheina, L S; Kolesnikov, A I [RDIEE, Moscow (Russian Federation)

    1999-12-31

    The project encompassed following activities: Elaboration of a description of the Russian dairy sector including a mapping of the entire sector in respect of production capacity, actual production, products, production technologies and energy consumption; Energy audits at twelve selected dairies with different typical productions; Elaboration of an `Energy Audit Guidance` which describes how to perform energy audits in dairies and where to expect energy saving possibilities. The energy savings possibilities are often due to the same kind of problems, e.g. low production, inefficient equipment or manually control of the process equipment. The main problems that Russian dairies faces can be divided into the following categories: Old and inefficient technological equipment which is operated at low capacity with very low energy efficiency; Lack of knowledge about new energy efficient technologies; Financial problems which causes low interest and few possibilities for using funds for investment in energy efficient equipment; Energy savings do not lead to personal gains for the persons in the dairy management or other employees which causes low interest in energy savings. At some dairies it seemd to be a problem for the management to adapt to the new and very different conditions for enterprises in Russian today, where sales, production, production capacity and raw milk available are interconnected. With respect to energy matters it was often a wish to replace existing oversized equipment with new equipment of the same size no matter that it is unlikely that the production will increase considerable in the future. The project has discovered that there is a need for demonstrating energy saving measures by implementation because it was in many ways hard for the dairy management`s to believe that, the energy consumption could be reduced dramatically without affecting the production or the processes. Furthermore, the project has discovered a need for transferring to the

  6. Energy audit at Russian dairies. Energy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Draborg, S. [Dansk Energi Analyse A/S, Vanloese (Denmark); Sheina, L.S.; Kolesnikov, A.I. [RDIEE, Moscow (Russian Federation)

    1998-12-31

    The project encompassed following activities: Elaboration of a description of the Russian dairy sector including a mapping of the entire sector in respect of production capacity, actual production, products, production technologies and energy consumption; Energy audits at twelve selected dairies with different typical productions; Elaboration of an `Energy Audit Guidance` which describes how to perform energy audits in dairies and where to expect energy saving possibilities. The energy savings possibilities are often due to the same kind of problems, e.g. low production, inefficient equipment or manually control of the process equipment. The main problems that Russian dairies faces can be divided into the following categories: Old and inefficient technological equipment which is operated at low capacity with very low energy efficiency; Lack of knowledge about new energy efficient technologies; Financial problems which causes low interest and few possibilities for using funds for investment in energy efficient equipment; Energy savings do not lead to personal gains for the persons in the dairy management or other employees which causes low interest in energy savings. At some dairies it seemd to be a problem for the management to adapt to the new and very different conditions for enterprises in Russian today, where sales, production, production capacity and raw milk available are interconnected. With respect to energy matters it was often a wish to replace existing oversized equipment with new equipment of the same size no matter that it is unlikely that the production will increase considerable in the future. The project has discovered that there is a need for demonstrating energy saving measures by implementation because it was in many ways hard for the dairy management`s to believe that, the energy consumption could be reduced dramatically without affecting the production or the processes. Furthermore, the project has discovered a need for transferring to the

  7. Evaluation Of Career Guidance Program In Vocational High School

    Directory of Open Access Journals (Sweden)

    Martaningsih Sri Tutur

    2018-01-01

    This review of career guidance program evaluation is conducted qualitatively through surveys, interviews and leiterature studies to provide an overview of evaluation program and its relevance to the necessity. Understanding the quality, weaknesses, obstacles to service implementation, and potential utilization are expected to improve career guidance effectiveness services in vocational high school. An evaluation on the overall career guidance program, will provide feedback for ongoing improvement. Various evaluation models are available, it needs to be selected about the relevance to the career counseling program characteristics, so that evaluation feedback is more optimal.

  8. Development of JOYO operational guidance system for emergency condition

    International Nuclear Information System (INIS)

    Takatsuto, Hiroshi; Owada, Toshio; Morimoto, Makoto; Aoki, Hiroshi; Tokita, Mitsuhiko; Terunuma, Seiichi

    1989-01-01

    Operational guidance system in JOYO has been developed for safe and stable plant operations and improvement of operational reliability. JOYCAT (JOYO Consulting and Analysing Tool), one of the JOYO operational guidance systems, supports the plant operator to present the causal alarm and select the suitable guidance manual in anomaly situations using artificial intelligence technology. Verification test of JOYCAT was performed using a JOYO operator-training simulator and on-line operation was started by partially linking to the actual plant in May 1988. As the result, the proper diagnosis function was confirmed in the actual plant. (author)

  9. Guidance on Dependence Assessment in SPAR-H

    Energy Technology Data Exchange (ETDEWEB)

    April M. Whaley

    2012-06-01

    As part of the effort to develop the SPAR-H user guidance, particular attention was paid to the assessment of dependence in order to address user questions about proper application of dependence. This paper presents a discussion of dependence from a psychological perspective and provides guidance on applying this information during the qualitative analysis of dependence to ensure more realistic and appropriate dependence assessments with the SPAR-H method. While this guidance was developed with SPAR-H in mind, it may be informative to other human reliability analysis methods that also use a THERP-based dependence approach, particularly if applied at the human failure event level.

  10. Strapdown Homing Guidance System Design for Some Ammunition

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The strapdown homing guidance system for some ammunition was mainly studied. A strong tracking Kalman filter was designed for the strapdown homing guidance system using the information measured by the strapdown homing seeker to estimate relative movement variables between the ammunition and target. Then the optimal proportional law, which using the estimated information, guided the ammunition. Simulation results show that the designed strapdown homing guidance system with strong tracking Kalman filter can attack the maneuvering target effectively, and satisfy the performance index for the guided ammunition system.

  11. WODA Technical Guidance on Underwater Sound from Dredging.

    Science.gov (United States)

    Thomsen, Frank; Borsani, Fabrizio; Clarke, Douglas; de Jong, Christ; de Wit, Pim; Goethals, Fredrik; Holtkamp, Martine; Martin, Elena San; Spadaro, Philip; van Raalte, Gerard; Victor, George Yesu Vedha; Jensen, Anders

    2016-01-01

    The World Organization of Dredging Associations (WODA) has identified underwater sound as an environmental issue that needs further consideration. A WODA Expert Group on Underwater Sound (WEGUS) prepared a guidance paper in 2013 on dredging sound, including a summary of potential impacts on aquatic biota and advice on underwater sound monitoring procedures. The paper follows a risk-based approach and provides guidance for standardization of acoustic terminology and methods for data collection and analysis. Furthermore, the literature on dredging-related sounds and the effects of dredging sounds on marine life is surveyed and guidance on the management of dredging-related sound risks is provided.

  12. Guidance and control of swarms of spacecraft

    Science.gov (United States)

    Morgan, Daniel James

    There has been considerable interest in formation flying spacecraft due to their potential to perform certain tasks at a cheaper cost than monolithic spacecraft. Formation flying enables the use of smaller, cheaper spacecraft that distribute the risk of the mission. Recently, the ideas of formation flying have been extended to spacecraft swarms made up of hundreds to thousands of 100-gram-class spacecraft known as femtosatellites. The large number of spacecraft and limited capabilities of each individual spacecraft present a significant challenge in guidance, navigation, and control. This dissertation deals with the guidance and control algorithms required to enable the flight of spacecraft swarms. The algorithms developed in this dissertation are focused on achieving two main goals: swarm keeping and swarm reconfiguration. The objectives of swarm keeping are to maintain bounded relative distances between spacecraft, prevent collisions between spacecraft, and minimize the propellant used by each spacecraft. Swarm reconfiguration requires the transfer of the swarm to a specific shape. Like with swarm keeping, minimizing the propellant used and preventing collisions are the main objectives. Additionally, the algorithms required for swarm keeping and swarm reconfiguration should be decentralized with respect to communication and computation so that they can be implemented on femtosats, which have limited hardware capabilities. The algorithms developed in this dissertation are concerned with swarms located in low Earth orbit. In these orbits, Earth oblateness and atmospheric drag have a significant effect on the relative motion of the swarm. The complicated dynamic environment of low Earth orbits further complicates the swarm-keeping and swarm-reconfiguration problems. To better develop and test these algorithms, a nonlinear, relative dynamic model with J2 and drag perturbations is developed. This model is used throughout this dissertation to validate the algorithms

  13. Health systems guidance appraisal--a critical interpretive synthesis.

    Science.gov (United States)

    Ako-Arrey, Denis E; Brouwers, Melissa C; Lavis, John N; Giacomini, Mita K

    2016-01-22

    Health systems guidance (HSG) are systematically developed statements that assist with decisions about options for addressing health systems challenges, including related changes in health systems arrangements. However, the development, appraisal, and reporting of HSG poses unique conceptual and methodological challenges related to the varied types of evidence that are relevant, the complexity of health systems, and the pre-eminence of contextual factors. To address this gap, we are conducting a program of research that aims to create a tool to support the appraisal of HSG and further enhance HSG development and reporting. The focus of this paper was to conduct a knowledge synthesis of the published and grey literatures to determine quality criteria (concepts) relevant for this process. We applied a critical interpretive synthesis (CIS) approach to knowledge synthesis that enabled an iterative, flexible, and dynamic analysis of diverse bodies of literature in order to generate a candidate list of concepts that will constitute the foundational components of the HSG tool. Using our review questions as compasses, we were able to guide the search strategy to look for papers based on their potential relevance to HSG appraisal, development, and reporting. The search strategy included various electronic databases and sources, subject-specific journals, conference abstracts, research reports, book chapters, unpublished data, dissertations, and policy documents. Screening the papers and data extraction was completed independently and in duplicate, and a narrative approach to data synthesis was executed. We identified 43 papers that met eligibility criteria. No existing review was found on this topic, and no HSG appraisal tool was identified. Over one third of the authors implicitly or explicitly identified the need for a high-quality tool aimed to systematically evaluate HSG and contribute to its development/reporting. We identified 30 concepts that may be relevant to the

  14. Schwannoma in the porta hepatis - laparoscopic excision under laparoscopic ultrasound guidance.

    Science.gov (United States)

    Sebastian, Maciej; Sroczyński, Maciej; Donizy, Piotr; Rudnicki, Jerzy

    2017-09-01

    Schwannomas are usually benign tumors attached to peripheral nerves and are rarely found in the gastrointestinal tract. Schwannomas in the porta hepatis are extremely rare, with only 15 cases described in the literature to date. A 22-year-old female patient presented with colicky upper abdominal pain lasting 3 months. Magnetic resonance imaging of the abdominal cavity revealed a tumor in the porta hepatis. The patient was qualified for laparoscopy. The tumor was totally excised laparoscopically under guidance of laparoscopic ultrasound without intra- or postoperative complications. Postoperative histopathological examination confirmed the porta hepatic schwannoma. The patient recovered uneventfully with very good cosmetic results. In the follow-up period of 5 months we have not observed any abdominal or general health problems. The present case is the first report in the world of laparoscopic ultrasound guided laparoscopic excision of a porta hepatic schwannoma.

  15. Lifelong guidance: How guidance and counselling support lifelong learning in the contrasting contexts of China and Denmark

    Science.gov (United States)

    Zhang, Zhixin

    2016-10-01

    Due to the effects of globalisation and rapid technological development, traditional linear life course patterns of the past are gradually disappearing, and this affects education and learning systems as well as labour markets. Individuals are forced to develop lifestyles and survival strategies to manage job insecurity and make their skills and interests meet labour market needs. In modern attempts to develop and implement institutional provision for lifelong learning, guidance and counselling play an important role. The current Danish guidance system is well-organised, highly structured and professionalised. By contrast, Chinese guidance is still fragmented and "sectorisational". This paper explores whether elements of the highly structured and professionalised Danish guidance system and practice might be applicable to the Chinese context. The author begins by outlining international and national factors which are affecting citizens' life and career planning. She then presents and discusses the evolution of guidance and the different elements of provision in each of the two countries. Next, She compares the concepts and goals of "lifelong guidance" in Denmark and China, pointing out their similarities and differences and their respective strengths and weaknesses. The paper concludes with some suggestions for the further development of guidance in China.

  16. Nuclear magnetic resonance tomography in Hallervorden-Spatz's syndrome

    International Nuclear Information System (INIS)

    Vogl, T.; Bauer, M.; Seiderer, M.; Rath, M.

    1984-01-01

    Two patients (mother and son) with Hallervorden-Spatz's syndrome were examined both via CT and Nuclear Magnetic Resonance (NMR), using different measuring modes. In the patient with progressing disease pathological findings were seen in the right and left putamen with CT and NMR. All examinations in the mother with a less progressive syndrome were without any result. Information obtained via NMR did not yield significantly more relevant data than computed tomography. (orig.) [de

  17. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Magnetic resonance (MR) defecography is a special ... with you. top of page What are the benefits vs. risks? Benefits MR defecography helps assess pelvic ...

  18. Quantum Proximity Resonances

    International Nuclear Information System (INIS)

    Heller, E.J.

    1996-01-01

    It is well known that at long wavelengths λ an s-wave scatterer can have a scattering cross section σ on the order of λ 2 , much larger than its physical size, as measured by the range of its potential. Very interesting phenomena can arise when two or more identical scatterers are placed close together, well within one wavelength. We show that, for a pair of identical scatterers, an extremely narrow p-wave open-quote open-quote proximity close-quote close-quote resonance develops from a broader s-wave resonance of the individual scatterers. A new s-wave resonance of the pair also appears. The relation of these proximity resonances (so called because they appear when the scatterers are close together) to the Thomas and Efimov effects is discussed. copyright 1996 The American Physical Society

  19. Resonances in QCD

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, Matthias F.M., E-mail: m.lutz@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Technische Universität Darmstadt, D-64289 Darmstadt (Germany); Lange, Jens Sören, E-mail: Soeren.Lange@exp2.physik.uni-giessen.de [II. Physikalisches Institut, Justus-Liebig-Universität Giessen, D-35392 Giessen (Germany); Pennington, Michael, E-mail: michaelp@jlab.org [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States); Bettoni, Diego [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara, 44122 Ferrara (Italy); Brambilla, Nora [Physik Department, Technische Universität München, D-85747 Garching (Germany); Crede, Volker [Department of Physics, Florida State University, Tallahassee, FL 32306 (United States); Eidelman, Simon [Novosibirsk State University, Novosibirsk 630090 (Russian Federation); Budker Istitute of Nuclear Physics SB RAS, Novosibirsk 630090 (Russian Federation); Gillitzer, Albrecht [Institut für Kernphysik, Forschungszentrum Jülich GmbH, D-52425 Jülich (Germany); Gradl, Wolfgang [Institut für Kernphysik, Johannes Gutenberg-Universität Mainz, D-55128 Mainz (Germany); Lang, Christian B. [Institut für Physik, Universität Graz, A-8010 Graz (Austria); Metag, Volker [II. Physikalisches Institut, Justus-Liebig-Universität Giessen, D-35392 Giessen (Germany); Nakano, Takashi [Research Center for Nuclear Physics, Osaka University, Osaka 567-0047 (Japan); and others

    2016-04-15

    We report on the EMMI Rapid Reaction Task Force meeting ‘Resonances in QCD’, which took place at GSI October 12–14, 2015. A group of 26 people met to discuss the physics of resonances in QCD. The aim of the meeting was defined by the following three key questions: • What is needed to understand the physics of resonances in QCD? • Where does QCD lead us to expect resonances with exotic quantum numbers? • What experimental efforts are required to arrive at a coherent picture? For light mesons and baryons only those with up, down and strange quark content were considered. For heavy–light and heavy–heavy meson systems, those with charm quarks were the focus. This document summarizes the discussions by the participants, which in turn led to the coherent conclusions we present here.

  20. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de